Ca rb o n Mo n o xid e Ala rm
User’s Guide
Model: KN-COPF-i
• 120V AC Wire-In
• Rechargeable Battery Backup
• Digital Display
• Interconnectable with other Kidde alarms
ATTENTION: Please take a few minutes to thoroughly read this
user’s guide, w hich should be saved for future reference and
passed on to any subsequent ow ner.
Download from Www.Somanuals.com. All Manuals Search And Download.
Manual P/N 820-1387 Rev. A 03/08
Important Warning Statements
1. Information About Carbon Monoxide
WARNING: This product is intended for use in ordinary indoor
locations of family living units. It is not designed to measure com-
pliance w ith Occupational Safety and Health Administration
(OSHA), commercial or industrial standards. It is not suitable for
installation in hazardous locations as defined in the National
Electric Code.
Ge n e ra l Ca rb o n Mo n o xid e In fo rm a t io n
Carbon monoxide is a colorless, odorless and tasteless poison gas that
can be fatal when inhaled. CO inhibits the blood’s capacity to carry oxy-
gen.
Periodically review this alarm manual and discuss your CO alarm emer-
gency procedure with all the members of your family. Never ignore a CO
alarm. A true alarm is an indication of potentially dangerous levels of
CO. CO alarms are designed to alert you to the presence of CO before
an emergency – before most people would experience symptoms of CO
poisoning, giving you time to resolve the problem calmly.
The installation of this device should not be used as a substitute
for proper installation, use and maintenance of fuel burning
appliances, including appropriate ventilation and exhaust sys-
tems. It does not prevent CO from occurring, nor can it solve an
existing CO problem.
Determine if anyone in the household is experiencing symptoms of CO
poisoning. Many cases of reported CO poisoning indicate that while
victims are aware they are not well, they become so disoriented they are
unable to save themselves by either exiting the building or calling for
assistance. Also, young children and household pets may be the first
affected. You should take extra precautions to protect high-risk persons
from CO exposure because they may experience ill effects from CO at
levels that would not ordinarily affect a healthy adult.
WARNING: This device is designed to protect individuals from
acute effects of carbon monoxide exposure. It may not fully safe-
guard individuals w ith specific medical conditions. If in doubt,
consult a medical practitioner.
Individuals w ith medical problems may consider using w arning
devices w hich provide audible and visual signals for carbon
monoxide concentrations under 30 PPM.
This carbon monoxide alarm requires a continuous supply of elec-
trical pow er – it w ill not w ork w ithout pow er. Models w ithout
battery backup w ill not operate during pow er failure.
Sym p t o m s o f CO Po iso n in g
The following common symptoms are related to CO poisoning and
should be discussed with ALL members of the household.
This alarm has not been investigated for carbon monoxide detec-
tion below 70 PPM.
Mild Exposure:
Slight headache, nausea, vomiting, fatigue (often described as
“flu-like” symptoms).
Medium Exposure:
Severe throbbing headache, drowsiness, confusion, fast heart rate.
Contents of This User’s Guide
1. Information About Carbon Monoxide
2. Product Features and Specifications
3. Installation Locations
Extreme Exposure:
Unconsciousness, convulsions, cardio-respiratory failure, death.
If you experience even mild symptoms of CO poisoning, consult your
doctor immediately!
4. Installation Instructions
5. Alarm Characteristics
6. KN-COPF-i Operating Characteristics
7. Maintenance
8. Limited Warranty
Download from Www.Somanuals.com. All Manuals Search And Download.
1. Information About Carbon Monoxide
1. Information About Carbon Monoxide
Ca rb o n Mo n o xid e PPM Le ve ls
exchangers.
This model is equipped with a digital display that shows levels of CO
(displayed in PPM – parts per million). Learn the difference between dan-
gerous, high, mid and low levels.
• Vehicles and other combustion engines running in an open or closed
garage, attached or near a home.
• Burning charcoal or fuel in grills and hibachis in an enclosed area.
Co n d it io n s Th a t Ca n Pro d u ce Ca rb o n Mo n o xid e
The following conditions can result in transient CO situations:
Dangerous Levels:
When someone is experiencing symptoms of CO poisoning and CO
readings are generally above 100 PPM. Anytime someone is experiencing
the symptoms of CO poisoning this should be treated as an emergency.
See “What to do When the Alarm Sounds” (inside front cover).
• Excessive spillage or reverse venting of fuel-burning appliances caused
by outdoor ambient conditions, such as, wind direction and/or veloci-
ty, including high gusts of wind, heavy air in the vent pipes
(cold/humid air with extended periods between cycles).
High Levels:
Generally above 100 PPM, with no one experiencing symptoms. This
should be treated as an urgent situation. See “What to do When the
Alarm Sounds” (inside front cover).
• Negative pressure resulting from the use of exhaust fans.
• Simultaneous operation of several fuel-burning appliances competing
for limited internal air.
Mid Levels:
Generally between 50 PPM to 100 PPM. This should be cause for
concern and should not be ignored or dismissed. See “What to do
When the Alarm Sounds” (inside front cover).
• Vent pipe connections vibrating loose from clothes dryers, furnaces, or
water heaters.
Low Levels:
• Obstructions in, or unconventional, vent pipe designs which can
amplify the above situations.
Generally below 50 PPM. Kidde recommends you take action to
eliminate the source of CO. See “What to do When the Alarm Sounds”
(inside front cover).
• Extended operation of unvented fuel-burning devices (range, oven,
fireplace, etc.).
IMPORTANT: If the alarm sounds, it should be treated as a poten-
tially serious condition. See “What to do When the Alarm Sounds”
(inside front cover).
• Temperature inversions which can trap exhaust gases near the ground.
• Vehicle idling in an open or closed garage, or near a home.
Po ssib le So u rce s o f Ca rb o n Mo n o xid e
To be safe, know the possible sources of CO in your home. Keep fuel-
burning appliances and their chimneys and vents in good working condi-
tion. Learn the early symptoms of exposure, and if you suspect CO poi-
soning, move outside to fresh air and get emergency help. Your first line
of defense is an annual inspection and regular maintenance of your
appliances. Contact a licensed contractor or call your local utility compa-
ny for assistance.
Inside your home, appliances used for heating and cooking are the most
likely sources of CO. Vehicles running in attached garages can also
produce dangerous levels of CO.
CO can be produced when burning any fossil fuel, such as gasoline,
propane, natural gas, oil and wood. It can be produced by any fuel-
burning appliance that is malfunctioning, improperly installed, or not
ventilated correctly, such as:
In fo rm a t io n Ab o u t Ca rb o n Mo n o xid e Ala rm s –
Wh a t Th e y Ca n a n d Ca n n o t Do :
• Automobiles, furnaces, gas ranges/stoves, gas clothes dryers, water
heaters, portable fuel burning space heaters and generators,
fireplaces, wood-burning stoves and certain swimming pool heaters.
CO alarms provide early warning of the presence of CO, usually before a
healthy adult would experience symptoms. This early warning is possible,
however, only if your CO alarm is located, installed and maintained as
described in this guide.
• Blocked chimneys or flues, back drafts and changes in air pressure,
corroded or disconnected vent pipes, loose or cracked furnace
Because carbon monoxide is a cumulative poison, long-term exposures
Download from Www.Somanuals.com. All Manuals Search And Download.
1. Information About Carbon Monoxide
2. Product Features and Specifications
to low levels may cause symptoms, as well as short-term exposures to
high levels. This Kidde unit has a time-weighted alarm – the higher the
level of CO present, the sooner the alarm will be triggered.
Model KN-COPF-i
This CO alarm can only warn you of the presence of CO. It does not
prevent CO from occurring, nor can it solve an existing CO problem. If
your unit has alarmed and you’ve provided ventilation by leaving your
windows and doors open, the CO buildup may have dissipated by the
time help responds. Although your problem may appear to be
temporarily solved, it’s crucial that the source of the CO is determined
and that the appropriate repairs are made.
Digital
Display
Green LED
Red LED
This CO alarm is designed to act as a monitor; it is not designed for use
as a short-term testing device to perform a quick check for the presence
of CO.
Amber LED
Test/Reset
Button
Peak Level
Button
CO alarms have limitations. Like any other electronic device, CO alarms
are not fool-proof. CO alarms have a limited operational life. You must
test your CO alarm weekly, because it could fail to operate at any time.
If your CO alarm fails to test properly, or if its self-diagnostic test reveals
a malfunction, immediately have the unit replaced. This alarm will not
monitor CO levels while in an error condition.
CO alarms can only sense CO that reaches the unit’s sensor. It’s possible
that CO may be present in other areas without reaching the alarm. The
rate and ability by which CO reaches the alarm may be affected by:
Alarm
Sounder
• Doors or other obstructions.
• Fresh air from a vent, an open window or other source.
IMPORTANT: Seven (7) years after the initial pow er up, this alarm
w ill “beep” every 30 seconds and display "End" to indicate that it
is time to replace the alarm. Replace the alarm immediately! It
w ill not detect CO in this condition. See Maintenance Section for
more information regarding End of Life Notification.
• CO being present on one level of the home and not reaching a CO
alarm installed on a different level. (For example, CO in the basement
may not reach an alarm on the second level, near the bedrooms).
For these reasons, we recommend you provide complete coverage by
placing a CO alarm on every level of the home. Please carefully read all
information in sections 2 and 3 on properly installing this CO alarm.
To help identify the date to replace the alarm, a label has been affixed to
the inside of the cover. Write the “replace by” date (seven years from
power up) in a permanent marker on this label.
CO alarms cannot be used to detect the presence of natural gas
(methane), propane, butane, or other combustible fuels.
Instruct children never to touch, unplug or otherwise interfere with the
alarm. Warn children of the dangers of CO poisoning.
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Product Features and Specifications
3. Installation Locations
Temperature:
Re co m m e n d e d In st a lla t io n Lo ca t io n s
Operating Range: 40°F (4.4°C) to 100°F (37.8°C)
CO alarms should be mounted in or
near bedrooms and living areas. It is
recommended that you install a Kidde
CO alarm on each level of your home.
Humidity:
Operating range: 10-95% non-condensing
Audible Alarm:
85+ dB at 10’ @ 3.4±0.5 KHz pulsing alarm
When choosing your installation loca-
tions, make sure you can hear the
alarm from all sleeping areas. If you
install only one CO alarm in your
Sensor:
Electrochemical
Recommended Locations
home, install it near bedrooms, not in the basement or furnace room.
Pow er:
120 volts AC, 60 Hz, 30 mA max, rechargeable battery back-up
• When wall mounting, place out of reach of children. Under no cir-
cumstances should children be allowed to handle the CO alarm.
Accuracy of Digital Display (Model KN-COP-IC only):
30-999 PPM +/-30% when measured in conditions of 80° F (+/- 10° F),
atmospheric pressure +/- 10% and 40% +/- 3% relative humidity.
Display readings may vary slightly depending on changes in the ambient
condition (temperature, humidity) and the condition of the sensor.
• Placing the alarm at eye level allows for optimum monitoring of the
digital display.
Lo ca t io n s To Avo id
Alarm Response Times:
70 PPM = 60-240 min., 150 PPM = 10-50 min., 400 PPM = 4-15 min.
IMPORTANT: Improper location can affect the sensitive electronic com-
ponents in this alarm. To avoid causing damage to the unit, to provide
optimum performance, and to prevent unnecessary nuisance alarms:
Interconnection w ith Other Alarms:
This Kidde CO alarm can be used as a single-station alarm or intercon-
nected with other Kidde alarms. This alarm can be interconnected direct-
ly with these Kidde models:
• Do not install in kitchens, garages or furnace rooms that may expose
the sensor to substances that could damage or contaminate it.
• Do not install in areas where the temperature is colder than 40°F
(4.4°C) or hotter than 100°F (37.8°C) such as crawl spaces, attics,
porches and garages.
Ionization smoke alarm models:
1235, 1235CA, 1275, 1275CA, 1276,1276CA, 1285, 1285CA,
i12020, i12040, i12060, i12080, i12020CA, i12040CA, i12060CA,
RF-SM-ACDC, KN-SMFM-i
• Do not install within 5 ft. of heating or cooking appliances. (Kidde
recommends 15 ft. to prevent nuisance alarms).
Photoelectric smoke alarm models:
PE120, PE120CA, PI2000, PI2000CA
• Do not install near vents, flues, chimneys or any forced/unforced air
ventilation openings.
Heat alarm models:
HD135F, HD135FCA
• Do not install near ceiling fans, doors, windows or areas directly
exposed to the weather.
Carbon monoxide/Ionization smoke alarm models:
KN-COSM-IB, KN-COSM-IBCA
• Do not install in dead air spaces, such as peaks of vaulted ceilings or
gabled roofs, where CO may not reach the sensor in time to provide
early warning.
Carbon monoxide alarm models:
KN-COB-IC, KN-COP-IC, KN-COB-ICB, KN-COP-ICB
• Do not install on a switched or dimmer-controlled outlet.
Relay models:
CO120X, SM120X
• Do not install this unit near deep-cell large batteries. Large batteries
have emissions that can cause the alarm to perform at less than opti-
mum performance.
Strobe Light models:
SL177I
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Installation Locations
4. Installation Instructions
• Do not obstruct the vents located on the alarm. Do not place the
alarm where drapes, furniture or other objects block the flow of air to
the vents.
• With 18 alarms interconnected, it is still possible to interconnect up to
a total of six remote signaling devices and/or relay modules.
• The maximum wire run distance between the first and last unit in an
interconnected system is 1000’ (305 m).
4. Installation Instructions
• Make certain alarms are wired to a continuous, (non-switched) power
line. NOTE: Use standard UL-listed household wire (as required by local
codes) available at all electrical supply stores and most hardware
stores.
In t e rco n n e ct in g
CAUTION: Kidde (Fyrnetics/Lifesaver/Kidde/Nighthaw k/Pyrene)
alarms and accessories can only be interconnected w ith other
Kidde alarms and accessories. Connection of these devices to
another manufactures interconnect system, or connection w ith
equipment from another manufacturer into an existing Kidde
interconnect system could result in nuisance alarming, failure to
alarm, or damage to one or all of the devices in the interconnect
system.
FUSE OR CIRCUIT BREAKER
WHITE
RED
BLACK
• When compatible Kidde smoke alarms and heat alarms are
interconnected to your CO alarm, they will only respond to a smoke
or heat related event.
CONNECTOR
Op t io n a l
• When mixing Kidde alarms which have battery back-up with models
without battery back-up, be advised that the models without battery
back-up will not function during an AC power failure.
Acce sso ry
First CO Ala rm
Ad d it io n a l
CO Ala rm
(See list of compatible
Kidde devices)
In t e rco n n e ct Wirin g Dia g ra m
• For alarms that are being used as single station alarms, do not
connect the red wire to anything. Leave the red wire insulating cap in
place to make certain that the red wire cannot contact any metal
parts or the electrical box.
Wirin g
The diagram above illustrates interconnection wiring. Improper connec-
tion will result in damage to the alarm, failure to operate, or a shock
hazard.
• The appropriate power source is 120 Volt AC Single-Phase supplied
from a non-switchable circuit, which is not protected by a ground
fault interrupter.
CAUTION: Turn off the main pow er to the circuit before w iring
the alarm.
• All interconnectable alarms should be installed on a UL-listed or
recognized junction box. All connections should be made by a
qualified electrician and must conform to article 760 of the U.S.
National Electrical Code, NFPA 72 and/or any other codes having
jurisdiction in your area.
Wires on the AC Quick-Connector Alarm Harness:
Black
Connected to live (L) side of AC line
White Connected to neutral (N) side of AC line
• When alarms are interconnected, all interconnected units must be
powered from a single circuit.
Red
Connected to interconnect lines (red wires) of other units
in a multiple-station set-up
• A maximum of 24 Kidde devices may be interconnected in a multiple-
station arrangement. The interconnect system should not exceed the
NFPA interconnect limit of 12 smoke alarms and/or 18 alarms total
(smoke, CO, smoke/CO combination, heat, etc.).
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Installation Instructions
5. Alarm Characteristics
Mo u n t in g
Ca rb o n Mo n o xid e Ala rm In d ica t o r
• After selecting the proper location for
your CO alarm and wiring the AC Quick-
Connector harness, plug the AC Quick-
Connector into the mating connector in
the back of the alarm. Be sure the con-
nectors snap together securely.
When the alarm senses a dangerous level of CO, the unit will emit a
loud alarm pattern. The alarm pattern is four (4) quick beeps followed
by five (5) seconds of silence. This cycle repeats as long as a dangerous
CO conditions exist. The red Alarm LED will flash the same pattern (and
the PPM will be displayed on alarms with digital displays). The amber
LED (Initiating Alarm) of the unit(s) which has (have) detected the CO,
will light for the duration of the alarm.
• Push the excess wire back into the elec-
trical box.
WARNING: When powered by battery backup only, after four minutes,
the alarm will sound and flash only once every minute, until the alarm is
reset or the CO is eliminated.
• Install the alarm in the electrical box
using the four screws provided.
If this unit is interconnected with other Kidde CO alarms, the amber LED
(Initiating Alarm) of the unit which has detected the CO, will light for
the duration of the alarm. The other interconnected CO alarms will also
alarm to warn you that CO was detected but the amber LED will NOT
light.
• Turn on the AC power. The green AC
Power On Indicator should be lit when
the alarm is operating from AC power.
• The rechargeable battery is turned on
automatically when AC power is sup-
plied.
If interconnected to other Kidde alarms and the backup battery (if
equipped) is low or missing, or if the unit malfunctions, it will display
other readings (and alarm differently) to alert you of specific conditions.
Please familiarize yourself, and other family members, to the difference
between a CO reading and and indication signifying a problem with the
unit itself.
NOTE: LOW BATTERY WARNING IS DISABLED FOR 24 HOURS
AFTER ALARM IS FIRST POWERED ON TO ALLOW THE BATTERY
TIME TO CHARGE.
Im p o rt a n t La b e ls Pro vid e d
WARNING: If at any time you test the alarm and it does not perform as
described, have it replaced immediately.
Two labels have been provided that have important information on what
to do in case of an alarm. Add the phone number of your emergency
service provider in the space provided. Place one label next to the alarm
after it is mounted, and one label near a fresh air source such as a door
or window.
Sm o ke Ala rm In d ica t o r (in t e rco n n e ct e d w it h CO Ala rm s)
When an interconnected Kidde smoke alarm detects smoke, the Kidde
CO alarm will sound a smoke/fire alarm pattern of three (3) long beeps,
followed by one (1) second of silence. This cycle repeats as long as
smoke signal persists to alert you of the condition. The word “Fire” will
scroll across the digital display. If this happens, leave the premises imme-
diately by your escape plan and call your local fire department.
WARNING: This unit is not a smoke alarm and will not detect smoke or
fire. It will only alarm for smoke/fire if it receives a signal from an inter-
connected Kidde smoke alarm.
NOTE: A smoke/fire alarm will override a CO alarm condition.
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Model KN-COPF-i Operating Characteristics
6. Model KN-COPF-i Operating Characteristics
Whenever the alarm is operating, the green Power LED is illuminated
and the digital display will display “0” to indicate the unit is monitoring
for CO. If the alarm senses dangerous levels of CO, the red Alarm LED
will flash, the amber LED will be lit, the digital display will indicate the
CO concentration in parts per million (PPM), and the alarm will emit an
audible alarm pattern.
LED Disp la y Sh o w s
Ala rm So u n d Un it St a t u s
Re co m m e n d a t io n
Steady “Err”
Red LED flashes every beep every
30 seconds 30 seconds
One quick
Unit malfunction
Press the Test/Reset
button. If “Err” con-
tinues, unit has mal-
functioned. Replace
immediately. Unit will
not respond to CO
This alarm will display a “0” if CO concentrations between 0 and 30
PPM have been detected within the last 30 seconds.
No display alternating 4 quick beeps, Alarm condition
with display of CO 5 seconds
Refer to “What to do
powered on battery When the Alarm
concentration every 60 silence,
backup. Dangerous Sounds” (inside front
When the unit is first powered up, the digital display will show three
“eights” – indicating the alarm is in the start-up mode. The three
“eights” will remain for approximately 20 seconds. After 20 seconds,
the alarm should display “0” and begin monitoring the air for CO and
will continue to do so as long as it receives power.
seconds. Red LED
flashes with beeps
repeating
concentrations of
cover).
Replace battery
every 60 secs CO detected
No display alternating None
with “0” every 60
seconds.
Green LED flashes
every 30 seconds
Normal operation
Verify AC power is
after first 4 minutes restored as soon as
of battery backup
operation. Unit
monitoring for CO
possible to maintain
battery.
The following table illustrates the possible digital displays, describes the
audible alarm patterns, and the recommended actions to take.
“End” displayed.
Red LED flashes
every 30 seconds
One quick beep End of unit life
every 30 seconds
Replace unit immedi-
ately. Unit will not
respond to CO.
Op e ra t in g a n d Ala rm Ch a ra ct e rist ics
LED Disp la y Sh o w s
Brief “888” along
with any number
between 100 and 300. silence,
Red LED flashes with beeps.
Green and amber LED’s on.
Ala rm So u n d Un it St a t u s
4 quick beeps, Self checking when None – CO has not
5 seconds AC powered (Test been detected.
button was pressed Numbers shown for
Re co m m e n d a t io n
Pe a k Le ve l Me m o ry
repeated once or unit was first
test purposes only
When the Peak Level button is pressed and held, the display shows the
highest CO reading taken by the CO alarm since its last reset or power
up. The Peak Level display feature will display levels between 11-999
PPM. Although the Peak Level feature will display levels below 30 PPM,
these levels will not result in an alarm no matter how long the device is
exposed to these levels. The Peak Level feature is helpful in identifying if
you have had a CO reading since resetting the alarm.
powered)
Steady “0” and green None
LED constantly on.
Normal AC
None
operation (sensing
no CO) and with a
good battery
“Lb” flashes
One quick
beep every
60 seconds
Battery voltage is
low.
Ensure AC power is
present and allow
battery to charge for
several hours
alternately with
any number.
Concentrations of CO between 1 and 30 PPM can often occur in nor-
mal, everyday conditions. Concentrations of CO below 30 PPM may be
an indication of a transient condition that may appear today and never
reappear. Some CO conditions may start out as low level leaks but could
develop into CO concentrations that may become harmful.
Red LED flashes
every 60 seconds.
A steady display of
CO concentration
4 quick beeps, Alarm condition.
Refer to “What to do
When the Alarm
Sounds” (inside front
cover)
5 seconds
silence,
Dangerous
from 30-999. Red
concentrations of
CO detected at
location of alarm.
LED flashes with beeps. Amber
LED shows initiating alarm.
repeating
Pe a k Le ve l Me m o ry Re se t
Press the Peak Level button; with the button still pressed, press the
Test/Reset button for two seconds and release. The number on the dis-
play will turn to “0”, the memory will be cleared and the alarm will
begin monitoring for CO. The Peak Level memory is also reset when the
unit loses power.
Steady “CO”
4 quick beeps, Interconnected CO Refer to “What to do
Red LED flashes with
beeps. Amber LED
NOT illuminated
5 seconds
silence,
alarm warning of a When the Alarm
CO condition at
different location.
Sounds” (inside front
cover)
repeating
“FirE”
Red LED flashes
with beeps
3 long beeps, Interconnected
Evacuate by your
escape plan
1 second
silence,
smoke alarm
warning of a
repeating
smoke/fire condition
Download from Www.Somanuals.com. All Manuals Search And Download.
7. Maintenance
7. Maintenance
NOTE: This unit is sealed. The cover is not removable.
Ala rm Re m o va l
Due to the loudness of the alarm, w e suggest that you place your
fingers over the sounder opening w hile testing your alarm.
Turn off the power to the alarm. Remove the alarm from the electrical
box by unscrewing the four screws under the cover securing the alarm.
Disconnect the AC Quick-Connector harness by pulling the connector
apart.
CAUTION: Continuous exposure to the high sound level of this
alarm over an extended period of time may cause hearing loss.
To permanently deactivate the battery for return or disposal purposes
prior to it reaching end of life: turn off AC power, remove the alarm
from the electrical box, disconnect the AC wires, puncture the label on
the back of the unit, and press the small switch using a pen or other
thin tool. The alarm will rapidly beep 10 times indicating that it has been
deactivated.
Te st in g
To test the alarm, press the Test/Reset button. If the unit is operating
properly, you should hear 4 quick beeps – followed by 5 seconds of
silence – followed by 4 quick beeps. The display will show three “eights”
and then show a number – usually around 200). The red LED will flash
along with the beeps and the amber LED will illuminate. Within several
seconds the unit will return to monitor for CO.
DO NOT USE THE ALARM IF THE LABEL HAS BEEN PUNCTURED!
Maintenance Tips
If interconnected to Kidde smoke alarms, pressing the Test/Reset button
on the CO alarm will have no effect on the smoke alarms. The smoke
alarms will not be tested and will not alarm. However, when pressing
the Test button on an interconnected smoke alarm, the CO alarm will
emit a Smoke/Fire audible and visual alarm pattern of 3 long beeps, 1
second of silence, repeated. NOTE: You do not need to press the Test
button to take a CO reading.
To keep your alarm in good working order, you must follow these simple
steps:
• Test the alarm once a week by pressing the Test/Reset button.
• Vacuum the alarm cover once a month to remove accumulated dust.
• Never use detergents or solvents to clean the alarm. Chemicals can
permanently damage or temporarily contaminate the sensor.
Ba t t e ry Ba cku p
This CO alarm is not battery operated. However, the alarm is equipped
with a rechargeable battery to supply short term back-up during a
power outage.
• Avoid spraying air fresheners, hair spray, paint or other aerosols near
the alarm.
• Do not paint the unit. Paint will seal the vents and interfere with
proper sensor operation.
IMPORTANT: Constant exposures to high or low humidity may
reduce the life of your battery and alarm.
Move the CO alarm to a remote location, to prevent possible damage or
contamination of the sensor, prior to performing any of the following:
End of Life Notification
Seven (7) years after unit is first powered, this alarm will “beep” every
30 seconds and display "End" to indicate that it is time to replace the
alarm (see Alarm Removal section for instructions). By pressing the
Test/Reset button the audible notification will be silenced for up to two
days giving you time to replace the unit at a more convenient time. The
display will alternate between the the CO ppm reading and "End" to
remind you to replace the unit right away. This silence feature can only
be used for a few days before it will no longer function and the beep
cannot be silenced. The alarm will still monitor and alarm for CO during
this period but all other functionality will be lost.
• Staining or stripping floors or furniture, painting or wall-papering
• Using aerosols or adhesives
WARNING: Reinstall the CO alarm as soon as possible to assure continu-
ous protection.
The following is a list of substances that at high levels can damage the
sensor or cause temporary readings that are not CO readings:
• Ethylene, ethanol, alcohol, iso-propanol, benzene, toluene, ethyl
acetate, hydrogen, hydrogen sulfide and sulfur dioxide.
Once AC power has been removed from unit after reaching its end of
service life, the battery will discharge itself to render the unit safe for
disposal.
• Also most aerosol sprays, alcohol based products, paint, thinner, sol-
vent, adhesive, hair spray, aftershave, perfume, auto exhaust (cold
start) and some cleaning agents.
Download from Www.Somanuals.com. All Manuals Search And Download.
SEVEN YEAR LIMITED WARRANTY
Warranty Coverage: The manufacturer warrants to the original consumer purchaser, that
this product will be free of defects in material and workmanship for a period of seven (7)
years from date of purchase. The manufacturer’s liability hereunder is limited to replacement
of the product, repair of the product or replacement of the product with repaired product at
the discretion of the manufacturer. This warranty is void if the product has been damaged by
accident, unreasonable use, neglect, tampering or other causes not arising from defects in
material or workmanship. This warranty extends to the original consumer purchaser of the
product only.
Warranty Disclaimers: Any implied warranties arising out of this sale, including but not
limited to the implied warranties of description, merchantability and fitness for a particular
purpose, are limited in duration to the above warranty period. In no event shall the
Manufacturer be liable for loss of use of this product or for any indirect, special, incidental or
consequential damages, or costs, or expenses incurred by the consumer or any other user of
this product, whether due to a breach of contract, negligence, strict liability in tort or
otherwise. The Manufacturer shall have no liability for any personal injury, property damage
or any special, incidental, contingent or consequential damage of any kind resulting from gas
leakage, fire or explosion. Some states do not allow limitations on how long an implied
warranty lasts, so the above limitation may not apply to you. Some states do not allow the
exclusion or limitation of consequential or incidental damages, so the above limitations or
exclusions may not apply to you.
Legal Remedies: This warranty gives you specific legal rights and you may also have other
rights that vary from state to state.
Warranty Performance: During the above warranty period, your product will be replaced
with a comparable product if the defective product is returned in a postage paid package to
the following address: Kidde, Customer Service Department, 1016 Corporate Park Drive,
Mebane, NC 27302 USA, together with proof of purchase date. Please include a note
describing the problem when you return the unit. The replacement product will be in
warranty for the remainder of the original warranty period or for six months, whichever is
longer. Other than the cost of postage, no charge will be made for replacement of the
defective product. In many cases the quickest way to exchange your alarm is to return it to
the original place of purchase. If you have questions, call the Kidde Customer Service
Department.
IMPORTANT: Do not remove unit back cover. Back cover removal w ill void w arranty.
Your Kidde Carbon Monoxide Alarm is not a substitute for property, disability, life or other
insurance of any kind. Appropriate insurance coverage is your responsibility. Consult your
insurance agent.
Also, Kidde makes no warranty, express or implied, written or oral, including that of
merchantability or fitness for any particular purpose, with respect to the battery.
The above warranty may not be altered except in writing signed by both parties hereto.
FOR QUESTIONS OR MORE INFORMATION
Call our Consumer Hotline at 1-800-880-6788 or contact
us on our website at w w w.kidde.com
Kidde, 1016 Corporate Park Drive, Mebane, NC 27302
Download from Www.Somanuals.com. All Manuals Search And Download.
U.S. Patent 6,976,883
|