Kidde Carbon Monoxide Alarm KN COPF I User Manual

Ca rb o n Mo n o xid e Ala rm  
Users Guide  
Model: KN-COPF-i  
• 120V AC Wire-In  
Rechargeable Battery Backup  
• Digital Display  
Interconnectable with other Kidde alarms  
ATTENTION: Please take a few minutes to thoroughly read this  
users guide, w hich should be saved for future reference and  
passed on to any subsequent ow ner.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Manual P/N 820-1387 Rev. A 03/08  
Important Warning Statements  
1. Information About Carbon Monoxide  
WARNING: This product is intended for use in ordinary indoor  
locations of family living units. It is not designed to measure com-  
pliance w ith Occupational Safety and Health Administration  
(OSHA), commercial or industrial standards. It is not suitable for  
installation in hazardous locations as defined in the National  
Electric Code.  
Ge n e ra l Ca rb o n Mo n o xid e In fo rm a t io n  
Carbon monoxide is a colorless, odorless and tasteless poison gas that  
can be fatal when inhaled. CO inhibits the bloods capacity to carry oxy-  
gen.  
Periodically review this alarm manual and discuss your CO alarm emer-  
gency procedure with all the members of your family. Never ignore a CO  
alarm. A true alarm is an indication of potentially dangerous levels of  
CO. CO alarms are designed to alert you to the presence of CO before  
an emergency – before most people would experience symptoms of CO  
poisoning, giving you time to resolve the problem calmly.  
The installation of this device should not be used as a substitute  
for proper installation, use and maintenance of fuel burning  
appliances, including appropriate ventilation and exhaust sys-  
tems. It does not prevent CO from occurring, nor can it solve an  
existing CO problem.  
Determine if anyone in the household is experiencing symptoms of CO  
poisoning. Many cases of reported CO poisoning indicate that while  
victims are aware they are not well, they become so disoriented they are  
unable to save themselves by either exiting the building or calling for  
assistance. Also, young children and household pets may be the first  
affected. You should take extra precautions to protect high-risk persons  
from CO exposure because they may experience ill effects from CO at  
levels that would not ordinarily affect a healthy adult.  
WARNING: This device is designed to protect individuals from  
acute effects of carbon monoxide exposure. It may not fully safe-  
guard individuals w ith specific medical conditions. If in doubt,  
consult a medical practitioner.  
Individuals w ith medical problems may consider using w arning  
devices w hich provide audible and visual signals for carbon  
monoxide concentrations under 30 PPM.  
This carbon monoxide alarm requires a continuous supply of elec-  
trical pow er – it w ill not w ork w ithout pow er. Models w ithout  
battery backup w ill not operate during pow er failure.  
Sym p t o m s o f CO Po iso n in g  
The following common symptoms are related to CO poisoning and  
should be discussed with ALL members of the household.  
This alarm has not been investigated for carbon monoxide detec-  
tion below 70 PPM.  
Mild Exposure:  
Slight headache, nausea, vomiting, fatigue (often described as  
flu-like” symptoms).  
Medium Exposure:  
Severe throbbing headache, drowsiness, confusion, fast heart rate.  
Contents of This Users Guide  
1. Information About Carbon Monoxide  
2. Product Features and Specifications  
3. Installation Locations  
Extreme Exposure:  
Unconsciousness, convulsions, cardio-respiratory failure, death.  
If you experience even mild symptoms of CO poisoning, consult your  
doctor immediately!  
4. Installation Instructions  
5. Alarm Characteristics  
6. KN-COPF-i Operating Characteristics  
7. Maintenance  
8. Limited Warranty  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Information About Carbon Monoxide  
1. Information About Carbon Monoxide  
Ca rb o n Mo n o xid e PPM Le ve ls  
exchangers.  
This model is equipped with a digital display that shows levels of CO  
(displayed in PPM – parts per million). Learn the difference between dan-  
gerous, high, mid and low levels.  
Vehicles and other combustion engines running in an open or closed  
garage, attached or near a home.  
Burning charcoal or fuel in grills and hibachis in an enclosed area.  
Co n d it io n s Th a t Ca n Pro d u ce Ca rb o n Mo n o xid e  
The following conditions can result in transient CO situations:  
Dangerous Levels:  
When someone is experiencing symptoms of CO poisoning and CO  
readings are generally above 100 PPM. Anytime someone is experiencing  
the symptoms of CO poisoning this should be treated as an emergency.  
See “What to do When the Alarm Sounds” (inside front cover).  
Excessive spillage or reverse venting of fuel-burning appliances caused  
by outdoor ambient conditions, such as, wind direction and/or veloci-  
ty, including high gusts of wind, heavy air in the vent pipes  
(cold/humid air with extended periods between cycles).  
High Levels:  
Generally above 100 PPM, with no one experiencing symptoms. This  
should be treated as an urgent situation. See “What to do When the  
Alarm Sounds” (inside front cover).  
• Negative pressure resulting from the use of exhaust fans.  
• Simultaneous operation of several fuel-burning appliances competing  
for limited internal air.  
Mid Levels:  
Generally between 50 PPM to 100 PPM. This should be cause for  
concern and should not be ignored or dismissed. See What to do  
When the Alarm Sounds” (inside front cover).  
Vent pipe connections vibrating loose from clothes dryers, furnaces, or  
water heaters.  
Low Levels:  
• Obstructions in, or unconventional, vent pipe designs which can  
amplify the above situations.  
Generally below 50 PPM. Kidde recommends you take action to  
eliminate the source of CO. See “What to do When the Alarm Sounds”  
(inside front cover).  
Extended operation of unvented fuel-burning devices (range, oven,  
fireplace, etc.).  
IMPORTANT: If the alarm sounds, it should be treated as a poten-  
tially serious condition. See “What to do When the Alarm Sounds”  
(inside front cover).  
Temperature inversions which can trap exhaust gases near the ground.  
Vehicle idling in an open or closed garage, or near a home.  
Po ssib le So u rce s o f Ca rb o n Mo n o xid e  
To be safe, know the possible sources of CO in your home. Keep fuel-  
burning appliances and their chimneys and vents in good working condi-  
tion. Learn the early symptoms of exposure, and if you suspect CO poi-  
soning, move outside to fresh air and get emergency help. Your first line  
of defense is an annual inspection and regular maintenance of your  
appliances. Contact a licensed contractor or call your local utility compa-  
ny for assistance.  
Inside your home, appliances used for heating and cooking are the most  
likely sources of CO. Vehicles running in attached garages can also  
produce dangerous levels of CO.  
CO can be produced when burning any fossil fuel, such as gasoline,  
propane, natural gas, oil and wood. It can be produced by any fuel-  
burning appliance that is malfunctioning, improperly installed, or not  
ventilated correctly, such as:  
In fo rm a t io n Ab o u t Ca rb o n Mo n o xid e Ala rm s –  
Wh a t Th e y Ca n a n d Ca n n o t Do :  
• Automobiles, furnaces, gas ranges/stoves, gas clothes dryers, water  
heaters, portable fuel burning space heaters and generators,  
fireplaces, wood-burning stoves and certain swimming pool heaters.  
CO alarms provide early warning of the presence of CO, usually before a  
healthy adult would experience symptoms. This early warning is possible,  
however, only if your CO alarm is located, installed and maintained as  
described in this guide.  
Blocked chimneys or flues, back drafts and changes in air pressure,  
corroded or disconnected vent pipes, loose or cracked furnace  
Because carbon monoxide is a cumulative poison, long-term exposures  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Information About Carbon Monoxide  
2. Product Features and Specifications  
to low levels may cause symptoms, as well as short-term exposures to  
high levels. This Kidde unit has a time-weighted alarm – the higher the  
level of CO present, the sooner the alarm will be triggered.  
Model KN-COPF-i  
This CO alarm can only warn you of the presence of CO. It does not  
prevent CO from occurring, nor can it solve an existing CO problem. If  
your unit has alarmed and youve provided ventilation by leaving your  
windows and doors open, the CO buildup may have dissipated by the  
time help responds. Although your problem may appear to be  
temporarily solved, its crucial that the source of the CO is determined  
and that the appropriate repairs are made.  
Digital  
Display  
Green LED  
Red LED  
This CO alarm is designed to act as a monitor; it is not designed for use  
as a short-term testing device to perform a quick check for the presence  
of CO.  
Amber LED  
Test/Reset  
Button  
Peak Level  
Button  
CO alarms have limitations. Like any other electronic device, CO alarms  
are not fool-proof. CO alarms have a limited operational life. You must  
test your CO alarm weekly, because it could fail to operate at any time.  
If your CO alarm fails to test properly, or if its self-diagnostic test reveals  
a malfunction, immediately have the unit replaced. This alarm will not  
monitor CO levels while in an error condition.  
CO alarms can only sense CO that reaches the units sensor. Its possible  
that CO may be present in other areas without reaching the alarm. The  
rate and ability by which CO reaches the alarm may be affected by:  
Alarm  
Sounder  
• Doors or other obstructions.  
Fresh air from a vent, an open window or other source.  
IMPORTANT: Seven (7) years after the initial pow er up, this alarm  
w ill “beep” every 30 seconds and display "End" to indicate that it  
is time to replace the alarm. Replace the alarm immediately! It  
w ill not detect CO in this condition. See Maintenance Section for  
more information regarding End of Life Notification.  
• CO being present on one level of the home and not reaching a CO  
alarm installed on a different level. (For example, CO in the basement  
may not reach an alarm on the second level, near the bedrooms).  
For these reasons, we recommend you provide complete coverage by  
placing a CO alarm on every level of the home. Please carefully read all  
information in sections 2 and 3 on properly installing this CO alarm.  
To help identify the date to replace the alarm, a label has been affixed to  
the inside of the cover. Write the “replace bydate (seven years from  
power up) in a permanent marker on this label.  
CO alarms cannot be used to detect the presence of natural gas  
(methane), propane, butane, or other combustible fuels.  
Instruct children never to touch, unplug or otherwise interfere with the  
alarm. Warn children of the dangers of CO poisoning.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Product Features and Specifications  
3. Installation Locations  
Temperature:  
Re co m m e n d e d In st a lla t io n Lo ca t io n s  
Operating Range: 40°F (4.4°C) to 100°F (37.8°C)  
CO alarms should be mounted in or  
near bedrooms and living areas. It is  
recommended that you install a Kidde  
CO alarm on each level of your home.  
Humidity:  
Operating range: 10-95% non-condensing  
Audible Alarm:  
85+ dB at 10’ @ 3.4±0.5 KHz pulsing alarm  
When choosing your installation loca-  
tions, make sure you can hear the  
alarm from all sleeping areas. If you  
install only one CO alarm in your  
Sensor:  
Electrochemical  
Recommended Locations  
home, install it near bedrooms, not in the basement or furnace room.  
Pow er:  
120 volts AC, 60 Hz, 30 mA max, rechargeable battery back-up  
• When wall mounting, place out of reach of children. Under no cir-  
cumstances should children be allowed to handle the CO alarm.  
Accuracy of Digital Display (Model KN-COP-IC only):  
30-999 PPM +/-30% when measured in conditions of 80° F (+/- 10° F),  
atmospheric pressure +/- 10% and 40% +/- 3% relative humidity.  
Display readings may vary slightly depending on changes in the ambient  
condition (temperature, humidity) and the condition of the sensor.  
• Placing the alarm at eye level allows for optimum monitoring of the  
digital display.  
Lo ca t io n s To Avo id  
Alarm Response Times:  
70 PPM = 60-240 min., 150 PPM = 10-50 min., 400 PPM = 4-15 min.  
IMPORTANT: Improper location can affect the sensitive electronic com-  
ponents in this alarm. To avoid causing damage to the unit, to provide  
optimum performance, and to prevent unnecessary nuisance alarms:  
Interconnection w ith Other Alarms:  
This Kidde CO alarm can be used as a single-station alarm or intercon-  
nected with other Kidde alarms. This alarm can be interconnected direct-  
ly with these Kidde models:  
• Do not install in kitchens, garages or furnace rooms that may expose  
the sensor to substances that could damage or contaminate it.  
• Do not install in areas where the temperature is colder than 40°F  
(4.4°C) or hotter than 100°F (37.8°C) such as crawl spaces, attics,  
porches and garages.  
Ionization smoke alarm models:  
1235, 1235CA, 1275, 1275CA, 1276,1276CA, 1285, 1285CA,  
i12020, i12040, i12060, i12080, i12020CA, i12040CA, i12060CA,  
RF-SM-ACDC, KN-SMFM-i  
• Do not install within 5 ft. of heating or cooking appliances. (Kidde  
recommends 15 ft. to prevent nuisance alarms).  
Photoelectric smoke alarm models:  
PE120, PE120CA, PI2000, PI2000CA  
• Do not install near vents, flues, chimneys or any forced/unforced air  
ventilation openings.  
Heat alarm models:  
HD135F, HD135FCA  
• Do not install near ceiling fans, doors, windows or areas directly  
exposed to the weather.  
Carbon monoxide/Ionization smoke alarm models:  
KN-COSM-IB, KN-COSM-IBCA  
• Do not install in dead air spaces, such as peaks of vaulted ceilings or  
gabled roofs, where CO may not reach the sensor in time to provide  
early warning.  
Carbon monoxide alarm models:  
KN-COB-IC, KN-COP-IC, KN-COB-ICB, KN-COP-ICB  
• Do not install on a switched or dimmer-controlled outlet.  
Relay models:  
CO120X, SM120X  
• Do not install this unit near deep-cell large batteries. Large batteries  
have emissions that can cause the alarm to perform at less than opti-  
mum performance.  
Strobe Light models:  
SL177I  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Installation Locations  
4. Installation Instructions  
• Do not obstruct the vents located on the alarm. Do not place the  
alarm where drapes, furniture or other objects block the flow of air to  
the vents.  
• With 18 alarms interconnected, it is still possible to interconnect up to  
a total of six remote signaling devices and/or relay modules.  
The maximum wire run distance between the first and last unit in an  
interconnected system is 1000’ (305 m).  
4. Installation Instructions  
• Make certain alarms are wired to a continuous, (non-switched) power  
line. NOTE: Use standard UL-listed household wire (as required by local  
codes) available at all electrical supply stores and most hardware  
stores.  
In t e rco n n e ct in g  
CAUTION: Kidde (Fyrnetics/Lifesaver/Kidde/Nighthaw k/Pyrene)  
alarms and accessories can only be interconnected w ith other  
Kidde alarms and accessories. Connection of these devices to  
another manufactures interconnect system, or connection w ith  
equipment from another manufacturer into an existing Kidde  
interconnect system could result in nuisance alarming, failure to  
alarm, or damage to one or all of the devices in the interconnect  
system.  
FUSE OR CIRCUIT BREAKER  
WHITE  
RED  
BLACK  
• When compatible Kidde smoke alarms and heat alarms are  
interconnected to your CO alarm, they will only respond to a smoke  
or heat related event.  
CONNECTOR  
Op t io n a l  
• When mixing Kidde alarms which have battery back-up with models  
without battery back-up, be advised that the models without battery  
back-up will not function during an AC power failure.  
Acce sso ry  
First CO Ala rm  
Ad d it io n a l  
CO Ala rm  
(See list of compatible  
Kidde devices)  
In t e rco n n e ct Wirin g Dia g ra m  
For alarms that are being used as single station alarms, do not  
connect the red wire to anything. Leave the red wire insulating cap in  
place to make certain that the red wire cannot contact any metal  
parts or the electrical box.  
Wirin g  
The diagram above illustrates interconnection wiring. Improper connec-  
tion will result in damage to the alarm, failure to operate, or a shock  
hazard.  
The appropriate power source is 120 Volt AC Single-Phase supplied  
from a non-switchable circuit, which is not protected by a ground  
fault interrupter.  
CAUTION: Turn off the main pow er to the circuit before w iring  
the alarm.  
• All interconnectable alarms should be installed on a UL-listed or  
recognized junction box. All connections should be made by a  
qualified electrician and must conform to article 760 of the U.S.  
National Electrical Code, NFPA 72 and/or any other codes having  
jurisdiction in your area.  
Wires on the AC Quick-Connector Alarm Harness:  
Black  
Connected to live (L) side of AC line  
White Connected to neutral (N) side of AC line  
• When alarms are interconnected, all interconnected units must be  
powered from a single circuit.  
Red  
Connected to interconnect lines (red wires) of other units  
in a multiple-station set-up  
• A maximum of 24 Kidde devices may be interconnected in a multiple-  
station arrangement. The interconnect system should not exceed the  
NFPA interconnect limit of 12 smoke alarms and/or 18 alarms total  
(smoke, CO, smoke/CO combination, heat, etc.).  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Installation Instructions  
5. Alarm Characteristics  
Mo u n t in g  
Ca rb o n Mo n o xid e Ala rm In d ica t o r  
• After selecting the proper location for  
your CO alarm and wiring the AC Quick-  
Connector harness, plug the AC Quick-  
Connector into the mating connector in  
the back of the alarm. Be sure the con-  
nectors snap together securely.  
When the alarm senses a dangerous level of CO, the unit will emit a  
loud alarm pattern. The alarm pattern is four (4) quick beeps followed  
by five (5) seconds of silence. This cycle repeats as long as a dangerous  
CO conditions exist. The red Alarm LED will flash the same pattern (and  
the PPM will be displayed on alarms with digital displays). The amber  
LED (Initiating Alarm) of the unit(s) which has (have) detected the CO,  
will light for the duration of the alarm.  
• Push the excess wire back into the elec-  
trical box.  
WARNING: When powered by battery backup only, after four minutes,  
the alarm will sound and flash only once every minute, until the alarm is  
reset or the CO is eliminated.  
Install the alarm in the electrical box  
using the four screws provided.  
If this unit is interconnected with other Kidde CO alarms, the amber LED  
(Initiating Alarm) of the unit which has detected the CO, will light for  
the duration of the alarm. The other interconnected CO alarms will also  
alarm to warn you that CO was detected but the amber LED will NOT  
light.  
Turn on the AC power. The green AC  
Power On Indicator should be lit when  
the alarm is operating from AC power.  
The rechargeable battery is turned on  
automatically when AC power is sup-  
plied.  
If interconnected to other Kidde alarms and the backup battery (if  
equipped) is low or missing, or if the unit malfunctions, it will display  
other readings (and alarm differently) to alert you of specific conditions.  
Please familiarize yourself, and other family members, to the difference  
between a CO reading and and indication signifying a problem with the  
unit itself.  
NOTE: LOW BATTERY WARNING IS DISABLED FOR 24 HOURS  
AFTER ALARM IS FIRST POWERED ON TO ALLOW THE BATTERY  
TIME TO CHARGE.  
Im p o rt a n t La b e ls Pro vid e d  
WARNING: If at any time you test the alarm and it does not perform as  
described, have it replaced immediately.  
Two labels have been provided that have important information on what  
to do in case of an alarm. Add the phone number of your emergency  
service provider in the space provided. Place one label next to the alarm  
after it is mounted, and one label near a fresh air source such as a door  
or window.  
Sm o ke Ala rm In d ica t o r (in t e rco n n e ct e d w it h CO Ala rm s)  
When an interconnected Kidde smoke alarm detects smoke, the Kidde  
CO alarm will sound a smoke/fire alarm pattern of three (3) long beeps,  
followed by one (1) second of silence. This cycle repeats as long as  
smoke signal persists to alert you of the condition. The word “Fire” will  
scroll across the digital display. If this happens, leave the premises imme-  
diately by your escape plan and call your local fire department.  
WARNING: This unit is not a smoke alarm and will not detect smoke or  
fire. It will only alarm for smoke/fire if it receives a signal from an inter-  
connected Kidde smoke alarm.  
NOTE: A smoke/fire alarm will override a CO alarm condition.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Model KN-COPF-i Operating Characteristics  
6. Model KN-COPF-i Operating Characteristics  
Whenever the alarm is operating, the green Power LED is illuminated  
and the digital display will display 0” to indicate the unit is monitoring  
for CO. If the alarm senses dangerous levels of CO, the red Alarm LED  
will flash, the amber LED will be lit, the digital display will indicate the  
CO concentration in parts per million (PPM), and the alarm will emit an  
audible alarm pattern.  
LED Disp la y Sh o w s  
Ala rm So u n d Un it St a t u s  
Re co m m e n d a t io n  
Steady “Err”  
Red LED flashes every beep every  
30 seconds 30 seconds  
One quick  
Unit malfunction  
Press the Test/Reset  
button. If Err” con-  
tinues, unit has mal-  
functioned. Replace  
immediately. Unit will  
not respond to CO  
This alarm will display a 0” if CO concentrations between 0 and 30  
PPM have been detected within the last 30 seconds.  
No display alternating 4 quick beeps, Alarm condition  
with display of CO 5 seconds  
Refer to “What to do  
powered on battery When the Alarm  
concentration every 60 silence,  
backup. Dangerous Sounds” (inside front  
When the unit is first powered up, the digital display will show three  
“eights” – indicating the alarm is in the start-up mode. The three  
“eights” will remain for approximately 20 seconds. After 20 seconds,  
the alarm should display 0” and begin monitoring the air for CO and  
will continue to do so as long as it receives power.  
seconds. Red LED  
flashes with beeps  
repeating  
concentrations of  
cover).  
Replace battery  
every 60 secs CO detected  
No display alternating None  
with “0” every 60  
seconds.  
Green LED flashes  
every 30 seconds  
Normal operation  
Verify AC power is  
after first 4 minutes restored as soon as  
of battery backup  
operation. Unit  
monitoring for CO  
possible to maintain  
battery.  
The following table illustrates the possible digital displays, describes the  
audible alarm patterns, and the recommended actions to take.  
End” displayed.  
Red LED flashes  
every 30 seconds  
One quick beep End of unit life  
every 30 seconds  
Replace unit immedi-  
ately. Unit will not  
respond to CO.  
Op e ra t in g a n d Ala rm Ch a ra ct e rist ics  
LED Disp la y Sh o w s  
Brief 888” along  
with any number  
between 100 and 300. silence,  
Red LED flashes with beeps.  
Green and amber LED’s on.  
Ala rm So u n d Un it St a t u s  
4 quick beeps, Self checking when None – CO has not  
5 seconds AC powered (Test been detected.  
button was pressed Numbers shown for  
Re co m m e n d a t io n  
Pe a k Le ve l Me m o ry  
repeated once or unit was first  
test purposes only  
When the Peak Level button is pressed and held, the display shows the  
highest CO reading taken by the CO alarm since its last reset or power  
up. The Peak Level display feature will display levels between 11-999  
PPM. Although the Peak Level feature will display levels below 30 PPM,  
these levels will not result in an alarm no matter how long the device is  
exposed to these levels. The Peak Level feature is helpful in identifying if  
you have had a CO reading since resetting the alarm.  
powered)  
Steady “0” and green None  
LED constantly on.  
Normal AC  
None  
operation (sensing  
no CO) and with a  
good battery  
Lb” flashes  
One quick  
beep every  
60 seconds  
Battery voltage is  
low.  
Ensure AC power is  
present and allow  
battery to charge for  
several hours  
alternately with  
any number.  
Concentrations of CO between 1 and 30 PPM can often occur in nor-  
mal, everyday conditions. Concentrations of CO below 30 PPM may be  
an indication of a transient condition that may appear today and never  
reappear. Some CO conditions may start out as low level leaks but could  
develop into CO concentrations that may become harmful.  
Red LED flashes  
every 60 seconds.  
A steady display of  
CO concentration  
4 quick beeps, Alarm condition.  
Refer to “What to do  
When the Alarm  
Sounds” (inside front  
cover)  
5 seconds  
silence,  
Dangerous  
from 30-999. Red  
concentrations of  
CO detected at  
location of alarm.  
LED flashes with beeps. Amber  
LED shows initiating alarm.  
repeating  
Pe a k Le ve l Me m o ry Re se t  
Press the Peak Level button; with the button still pressed, press the  
Test/Reset button for two seconds and release. The number on the dis-  
play will turn to “0”, the memory will be cleared and the alarm will  
begin monitoring for CO. The Peak Level memory is also reset when the  
unit loses power.  
Steady “CO”  
4 quick beeps, Interconnected CO Refer to “What to do  
Red LED flashes with  
beeps. Amber LED  
NOT illuminated  
5 seconds  
silence,  
alarm warning of a When the Alarm  
CO condition at  
different location.  
Sounds” (inside front  
cover)  
repeating  
FirE”  
Red LED flashes  
with beeps  
3 long beeps, Interconnected  
Evacuate by your  
escape plan  
1 second  
silence,  
smoke alarm  
warning of a  
repeating  
smoke/fire condition  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. Maintenance  
7. Maintenance  
NOTE: This unit is sealed. The cover is not removable.  
Ala rm Re m o va l  
Due to the loudness of the alarm, w e suggest that you place your  
fingers over the sounder opening w hile testing your alarm.  
Turn off the power to the alarm. Remove the alarm from the electrical  
box by unscrewing the four screws under the cover securing the alarm.  
Disconnect the AC Quick-Connector harness by pulling the connector  
apart.  
CAUTION: Continuous exposure to the high sound level of this  
alarm over an extended period of time may cause hearing loss.  
To permanently deactivate the battery for return or disposal purposes  
prior to it reaching end of life: turn off AC power, remove the alarm  
from the electrical box, disconnect the AC wires, puncture the label on  
the back of the unit, and press the small switch using a pen or other  
thin tool. The alarm will rapidly beep 10 times indicating that it has been  
deactivated.  
Te st in g  
To test the alarm, press the Test/Reset button. If the unit is operating  
properly, you should hear 4 quick beeps – followed by 5 seconds of  
silence – followed by 4 quick beeps. The display will show three eights”  
and then show a number – usually around 200). The red LED will flash  
along with the beeps and the amber LED will illuminate. Within several  
seconds the unit will return to monitor for CO.  
DO NOT USE THE ALARM IF THE LABEL HAS BEEN PUNCTURED!  
Maintenance Tips  
If interconnected to Kidde smoke alarms, pressing the Test/Reset button  
on the CO alarm will have no effect on the smoke alarms. The smoke  
alarms will not be tested and will not alarm. However, when pressing  
the Test button on an interconnected smoke alarm, the CO alarm will  
emit a Smoke/Fire audible and visual alarm pattern of 3 long beeps, 1  
second of silence, repeated. NOTE: You do not need to press the Test  
button to take a CO reading.  
To keep your alarm in good working order, you must follow these simple  
steps:  
Test the alarm once a week by pressing the Test/Reset button.  
Vacuum the alarm cover once a month to remove accumulated dust.  
• Never use detergents or solvents to clean the alarm. Chemicals can  
permanently damage or temporarily contaminate the sensor.  
Ba t t e ry Ba cku p  
This CO alarm is not battery operated. However, the alarm is equipped  
with a rechargeable battery to supply short term back-up during a  
power outage.  
• Avoid spraying air fresheners, hair spray, paint or other aerosols near  
the alarm.  
• Do not paint the unit. Paint will seal the vents and interfere with  
proper sensor operation.  
IMPORTANT: Constant exposures to high or low humidity may  
reduce the life of your battery and alarm.  
Move the CO alarm to a remote location, to prevent possible damage or  
contamination of the sensor, prior to performing any of the following:  
End of Life Notification  
Seven (7) years after unit is first powered, this alarm will beep” every  
30 seconds and display "End" to indicate that it is time to replace the  
alarm (see Alarm Removal section for instructions). By pressing the  
Test/Reset button the audible notification will be silenced for up to two  
days giving you time to replace the unit at a more convenient time. The  
display will alternate between the the CO ppm reading and "End" to  
remind you to replace the unit right away. This silence feature can only  
be used for a few days before it will no longer function and the beep  
cannot be silenced. The alarm will still monitor and alarm for CO during  
this period but all other functionality will be lost.  
• Staining or stripping floors or furniture, painting or wall-papering  
• Using aerosols or adhesives  
WARNING: Reinstall the CO alarm as soon as possible to assure continu-  
ous protection.  
The following is a list of substances that at high levels can damage the  
sensor or cause temporary readings that are not CO readings:  
Ethylene, ethanol, alcohol, iso-propanol, benzene, toluene, ethyl  
acetate, hydrogen, hydrogen sulfide and sulfur dioxide.  
Once AC power has been removed from unit after reaching its end of  
service life, the battery will discharge itself to render the unit safe for  
disposal.  
• Also most aerosol sprays, alcohol based products, paint, thinner, sol-  
vent, adhesive, hair spray, aftershave, perfume, auto exhaust (cold  
start) and some cleaning agents.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SEVEN YEAR LIMITED WARRANTY  
Warranty Coverage: The manufacturer warrants to the original consumer purchaser, that  
this product will be free of defects in material and workmanship for a period of seven (7)  
years from date of purchase. The manufacturers liability hereunder is limited to replacement  
of the product, repair of the product or replacement of the product with repaired product at  
the discretion of the manufacturer. This warranty is void if the product has been damaged by  
accident, unreasonable use, neglect, tampering or other causes not arising from defects in  
material or workmanship. This warranty extends to the original consumer purchaser of the  
product only.  
Warranty Disclaimers: Any implied warranties arising out of this sale, including but not  
limited to the implied warranties of description, merchantability and fitness for a particular  
purpose, are limited in duration to the above warranty period. In no event shall the  
Manufacturer be liable for loss of use of this product or for any indirect, special, incidental or  
consequential damages, or costs, or expenses incurred by the consumer or any other user of  
this product, whether due to a breach of contract, negligence, strict liability in tort or  
otherwise. The Manufacturer shall have no liability for any personal injury, property damage  
or any special, incidental, contingent or consequential damage of any kind resulting from gas  
leakage, fire or explosion. Some states do not allow limitations on how long an implied  
warranty lasts, so the above limitation may not apply to you. Some states do not allow the  
exclusion or limitation of consequential or incidental damages, so the above limitations or  
exclusions may not apply to you.  
Legal Remedies: This warranty gives you specific legal rights and you may also have other  
rights that vary from state to state.  
Warranty Performance: During the above warranty period, your product will be replaced  
with a comparable product if the defective product is returned in a postage paid package to  
the following address: Kidde, Customer Service Department, 1016 Corporate Park Drive,  
Mebane, NC 27302 USA, together with proof of purchase date. Please include a note  
describing the problem when you return the unit. The replacement product will be in  
warranty for the remainder of the original warranty period or for six months, whichever is  
longer. Other than the cost of postage, no charge will be made for replacement of the  
defective product. In many cases the quickest way to exchange your alarm is to return it to  
the original place of purchase. If you have questions, call the Kidde Customer Service  
Department.  
IMPORTANT: Do not remove unit back cover. Back cover removal w ill void w arranty.  
Your Kidde Carbon Monoxide Alarm is not a substitute for property, disability, life or other  
insurance of any kind. Appropriate insurance coverage is your responsibility. Consult your  
insurance agent.  
Also, Kidde makes no warranty, express or implied, written or oral, including that of  
merchantability or fitness for any particular purpose, with respect to the battery.  
The above warranty may not be altered except in writing signed by both parties hereto.  
FOR QUESTIONS OR MORE INFORMATION  
Call our Consumer Hotline at 1-800-880-6788 or contact  
us on our website at w w w.kidde.com  
Kidde, 1016 Corporate Park Drive, Mebane, NC 27302  
Download from Www.Somanuals.com. All Manuals Search And Download.  
U.S. Patent 6,976,883  

Indesit Dishwasher DIF04 User Manual
Ingersoll Rand Water Pump 66M2X0 XXX C User Manual
Intel Computer Hardware PM915 478 User Manual
Invacare Crib Toy ACC250 User Manual
Jotul Indoor Fireplace Jtul GI 425 DV User Manual
Jotul Indoor Fireplace Wood Insert User Manual
JVC Computer Monitor DT V1710CG User Manual
Kenmore Refrigerator 7957130 User Manual
KitchenAid Oven KAC 28 User Manual
KitchenAid Ventilation Hood Range Hood User Manual