Kenmore Air Cleaner D42 M32701 User Manual

OWNER’S MANUAL  
MODEL D42 M32701  
ELECTRONIC AIR CLEANER, IONIZER & VOC FILTER  
IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT  
Features  
Lifetime Electronic Filter never needs replacing—simply washes clean  
Electronically removes dust, mites, pollen, pet dander, mold, bacteria, viruses,  
tobacco smoke, cooking smoke and grease, and more down to 0.01 micron  
Activated Carbon Odour & Gas (VOC) Removal Filter removes Volatile Organic  
Compounds emitted from common sources within the home and office  
Dual Negative Ionizer restores the air’s natural ion balance  
Quiet 3-Speed Fan is comfortable for room occupants  
Performance Indicator Light shows Air Cleaner is operating properly at a glance  
Ideal for rooms up to 320 ft² (29.5 m²) for one room air change every 20 minutes  
SEARS CANADA INC., TORONTO, ONTARIO, M5B 2B8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLEANING INSTRUCTIONS  
TROUBLESHOOTING CHART  
The prefilter and collecting cell must be washed on a regular  
basis for the Air Cleaner to function at its peak efficiency.  
The frequency of cleaning will vary from one environment to  
another, therefore the cell should be checked monthly to  
determine cleaning schedule. On average, the cell should be  
washed every 2-3 months.  
PROBLEM  
CAUSE  
Fan does not operate  
Both Operation Lights off  
Unit not plugged in  
System switch not ON  
Fan switch not in proper position  
Lid not securely closed  
COLLECTING CELL  
Green Performance  
Light on  
Red Ion Light off  
Fan operating  
Both Operation Lights off  
Negative Ion switch not in ON  
1. Turn Air Cleaner OFF. Remove the cell from the Air  
Cleaner. Slide the prefilter and carbon filter out of the  
retaining brackets before cleaning.  
position  
Cell wet from washing  
Short in cell (see below)  
Cell wet from washing  
Cell plate(s) bent  
2. Rinse prefilter and cell, and spray completely with DAX  
Detergent (or non-chlorine, non-corrosive, non-abrasive,  
non-ammonia liquid household detergent). Let stand for  
5 minutes. Rinse well with hot water (120°F / 49°C  
maximum). Repeat process 3 times.  
Cell arcing excessively  
Cell dirty or large lint ball/hair  
caught in cell  
3. If dirt remains, let cell soak in a solution of DAX  
Detergent and hot water for 30 minutes.  
Broken ionizing wire(s)  
Prefilter is in backward (black  
4. For drying, place the cell on a 45° angle on one end,  
with the arrow pointing sideways, and let stand for 10-24  
hours. A hair dryer may be used to speed up drying  
time. Make sure the cell is completely dry before  
reinserting back into Air Cleaner. The arrow on the cell  
must point toward the fan blower.  
mesh should be visible on outside)  
Air Cleaner vibrating  
excessively  
Both Operation Lights on  
Cell not collecting dirt  
Unit not sitting on flat surface  
Cell is in backward (Arrow on cell  
should point towards fan blower)  
5. If arcing or snapping occurs or the lights do not come on  
when the cell is placed back in the unit and turned on,  
then remove the cell and allow to dry longer.  
The two Operation Lights, located behind the front grill, are  
also used as the high voltage fault indicator. If the fan is  
operating, but the lights do not come on, then there is a  
problem in the high voltage circuit. To determine what the  
problem is, turn the Air Cleaner OFF and remove the  
collecting cell. Close the lid and turn the Air Cleaner back  
ON. If the lights come back on, the problem lies in the cell.  
Check the cell for wetness from washing or look for a broken  
ionizing wire(s) or bent cell plate(s).  
ODOUR & GAS (VOC) REMOVAL FILTER  
Activated Carbon  
Odour & Gas (VOC)  
Filter  
Collecting Cell  
Prefilter  
1. The Activated Carbon Odour & Gas (VOC) Removal  
Filter must be replaced at regular intervals if odour  
removal is desired (approximately every 3-6 months).  
ODOUR REMOVAL FILTERS ARE NOT WASHABLE.  
If the lights do not come on, the problem is with the power  
board or Operation Light(s). If you are unable to correct any  
of the above problems, call 1-800-267-8305.  
TECHNICAL DATA  
CABINET  
1. Turn Air Cleaner OFF.  
Dimensions  
2. A soft, damp, lint-free cloth may be used to remove dirt  
and fingerprints from painted surfaces, grills and end  
panels.  
Width  
Depth  
Height  
20.0 in  
12.0 in  
5.0 in  
50.8 cm  
30.5 cm  
12.7 cm  
NEVER USE AN ABRASIVE CLEANER ON THE  
CABINET.  
Weight  
16.0 lbs  
7.3 kg  
WARNING  
Input Voltage  
120 V  
60 Hz  
DO  
NOT  
WASH  
COLLECTING  
CELL  
IN  
Power Consumption  
(maximum)  
85 Watts  
DISHWASHER.  
Never use any object to clean between the cell plates as  
this may cause damage to the plates or ionizing wires.  
Air Flow  
High  
Medium  
Low  
130 cfm  
80 cfm  
60 cfm  
221 m³/hr  
136 m³/hr  
102 m³/hr  
Never place the cell in an oven to dry.  
The edges of the cell may be sharp — handle with care.  
Cell Output Voltage  
6500 VDC @ < 1 mA  
Collecting Cell  
Surface  
756 in²  
4877 cm²  
Negative Ionizer  
-5000 VDC @ <.1 mA  
2 x 327.7 K/in³  
DAX Detergent, No. 32921,  
and the Activated Carbon  
Odour & Gas (VOC) Removal  
Filter, No. 32711, are  
available from your Sears  
outlet.  
Negative Ion Output  
2 x 20 K/cm³  
29.5 m²  
Ideal for rooms up to:  
(1 room air change  
every 20 minutes for  
maximum room size)  
320 ft²  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFEGUARDS  
Safety points you should know about your Electronic Air Cleaner and Ionizer.  
Caution:  
** Read Owner’s Manual and safeguards before using  
** Save Owner’s Manual for later use  
** Follow all warnings and instructions marked on Air Cleaner  
FOR YOUR PERSONAL SAFETY  
1. The Air Cleaner is equipped with a grounded plug. Do not  
If liquid has been spilled into the Air Cleaner, unplug the unit  
from the wall outlet and refer servicing to qualified service  
personnel.  
defeat the purpose of this plug by removing the grounding pin,  
as this may result in an electrical shock or create an unsafe  
condition.  
10. Do not use the Air Cleaner near open fire or flame, or sources  
of heat i.e. fireplaces, wood burning stoves, kerosene heaters,  
stove tops, ovens, etc.  
2. When the power cord or plug is damaged or frayed, unplug the  
Air Cleaner from the wall outlet and refer servicing to qualified  
service personnel.  
11. Do not use the Air Cleaner on soft surfaces i.e. beds, sofas.  
3. Do not overload wall outlets and extension cords, as this can  
result in fire or electric shock.  
12. Do not use the Air Cleaner when oxygen is being used or when  
combustible gases are present.  
4. Do not allow anything to rest on or roll over the power cord, and  
do not place the unit where power cord is subject to traffic or  
abuse. This may result in a shock or fire hazard.  
13. The Air Cleaner has slots or openings in the cabinet for  
ventilation purposes, to provide reliable operation of the unit,  
and to protect it from overheating. These openings must not be  
blocked or covered.  
5. Do not attempt to service the Air Cleaner yourself as opening or  
removing switch cover may expose you to dangerous voltage or  
other hazards. Refer all servicing to qualified personnel.  
14. The Air Cleaner should be operated only from the type of power  
source indicated on the rating label. If you are not sure of the  
type of power supply at your home, consult your local power  
company.  
6. Never push objects of any kind into the Air Cleaner through  
cabinet slots, as they may touch dangerous voltage points, or  
short out parts that could result in a fire or electric shock.  
15. It is normal for the Air Cleaner to make occasional snapping or  
popping sounds, particularly when being turned on after  
washing. If the snapping or popping is continuous or frequent,  
unplug the unit and call 1-800-267-8305.  
7. If the Air Cleaner has been dropped or the cabinet has been  
damaged, unplug the unit from the wall outlet and refer  
servicing to qualified service personnel.  
8. Unplug the Air Cleaner from the wall outlet before cleaning. Do  
not use liquid cleaners or aerosol cleaners on cabinet. Use a  
damp, lint-free cloth for cleaning, except when cleaning the cell.  
16. If the Air Cleaner does not operate normally by following the  
operating instructions, unplug the unit from the wall outlet and  
refer servicing to qualified service personnel.  
9. Do not use the Air Cleaner near water, i.e. near a bathtub, sink,  
laundry tub, in a wet basement, in the rain or near a swimming  
pool, etc.  
LIMITED ONE YEAR WARRANTY  
Your Electronic Air Cleaner is guaranteed for one (1) full year from the date of original purchase, against electrical and mechanical defects in  
material and workmanship, under normal use and maintenance, which will be repaired or replaced without charge, upon inspection by an  
authorized service center. The warranty does not include the Prefilter or Carbon Filter.  
This guarantee is in lieu of any other warranty, either expressed or implied.  
SEARS CANADA INC. will not be responsible for:  
1. Normal maintenance including cleaning or replacement of filters, as outlined in the Owner’s Manual.  
2. Damage or repairs needed as a consequence of any misuse, negligent handling, improper servicing, unauthorized alteration, improper  
operations or use on voltage other than that stamped on the Air Cleaner.  
3. Any personal injury, property damage, or any incidental or consequential damages of any kind, resulting from defects, malfunctions,  
misuse, or alteration of the product.  
4. Damage as a result of floods, winds, fires, lightning, accidents, corrosive atmosphere, or other conditions beyond the control of Sears  
Canada Inc.  
5. Parts, including filters not supplied or designated by Sears Canada Inc.  
If warranty service is required, take the Electronic Air Cleaner into the nearest Sears outlet or Sears Parts & Service Center, with a proof of  
purchase. The original carton and packaging must be used. If not, and if goods arrive damaged due to improper packaging, warranty will be  
void.  
For more information, call Toll Free 1-800-267-8305  
32701.pub  
05/06  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Invacare Mobility Aid Formula TRE User Manual
Jade Range Oven JTRH 36B 36 User Manual
JBL Speaker L820 User Manual
Jenn Air Oven JJW9830DDB User Manual
JL Audio Car Speaker SB F FCSZX 10W3v3 User Manual
JVC Car Amplifier KD ADV5580 User Manual
JVC Digital Camera GR DVM1 User Manual
Kenwood Car Speaker KFC 6972 User Manual
Kenwood CD Player CRD3569 A User Manual
Klipsch Speaker RB 10 User Manual