OWNER’S MANUAL
MODEL D42 M32701
ELECTRONIC AIR CLEANER, IONIZER & VOC FILTER
IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT
Features
•
•
Lifetime Electronic Filter never needs replacing—simply washes clean
Electronically removes dust, mites, pollen, pet dander, mold, bacteria, viruses,
tobacco smoke, cooking smoke and grease, and more down to 0.01 micron
Activated Carbon Odour & Gas (VOC) Removal Filter removes Volatile Organic
Compounds emitted from common sources within the home and office
Dual Negative Ionizer restores the air’s natural ion balance
Quiet 3-Speed Fan is comfortable for room occupants
Performance Indicator Light shows Air Cleaner is operating properly at a glance
Ideal for rooms up to 320 ft² (29.5 m²) for one room air change every 20 minutes
•
•
•
•
•
SEARS CANADA INC., TORONTO, ONTARIO, M5B 2B8
Download from Www.Somanuals.com. All Manuals Search And Download.
CLEANING INSTRUCTIONS
TROUBLESHOOTING CHART
The prefilter and collecting cell must be washed on a regular
basis for the Air Cleaner to function at its peak efficiency.
The frequency of cleaning will vary from one environment to
another, therefore the cell should be checked monthly to
determine cleaning schedule. On average, the cell should be
washed every 2-3 months.
PROBLEM
CAUSE
Fan does not operate
Both Operation Lights off
• Unit not plugged in
• System switch not ON
• Fan switch not in proper position
• Lid not securely closed
COLLECTING CELL
Green Performance
Light on
Red Ion Light off
Fan operating
Both Operation Lights off
• Negative Ion switch not in ON
1. Turn Air Cleaner OFF. Remove the cell from the Air
Cleaner. Slide the prefilter and carbon filter out of the
retaining brackets before cleaning.
position
• Cell wet from washing
• Short in cell (see below)
• Cell wet from washing
• Cell plate(s) bent
2. Rinse prefilter and cell, and spray completely with DAX
Detergent (or non-chlorine, non-corrosive, non-abrasive,
non-ammonia liquid household detergent). Let stand for
5 minutes. Rinse well with hot water (120°F / 49°C
maximum). Repeat process 3 times.
Cell arcing excessively
• Cell dirty or large lint ball/hair
caught in cell
3. If dirt remains, let cell soak in a solution of DAX
Detergent and hot water for 30 minutes.
• Broken ionizing wire(s)
• Prefilter is in backward (black
4. For drying, place the cell on a 45° angle on one end,
with the arrow pointing sideways, and let stand for 10-24
hours. A hair dryer may be used to speed up drying
time. Make sure the cell is completely dry before
reinserting back into Air Cleaner. The arrow on the cell
must point toward the fan blower.
mesh should be visible on outside)
Air Cleaner vibrating
excessively
Both Operation Lights on
Cell not collecting dirt
• Unit not sitting on flat surface
• Cell is in backward (Arrow on cell
should point towards fan blower)
5. If arcing or snapping occurs or the lights do not come on
when the cell is placed back in the unit and turned on,
then remove the cell and allow to dry longer.
The two Operation Lights, located behind the front grill, are
also used as the high voltage fault indicator. If the fan is
operating, but the lights do not come on, then there is a
problem in the high voltage circuit. To determine what the
problem is, turn the Air Cleaner OFF and remove the
collecting cell. Close the lid and turn the Air Cleaner back
ON. If the lights come back on, the problem lies in the cell.
Check the cell for wetness from washing or look for a broken
ionizing wire(s) or bent cell plate(s).
ODOUR & GAS (VOC) REMOVAL FILTER
Activated Carbon
Odour & Gas (VOC)
Filter
Collecting Cell
Prefilter
1. The Activated Carbon Odour & Gas (VOC) Removal
Filter must be replaced at regular intervals if odour
removal is desired (approximately every 3-6 months).
ODOUR REMOVAL FILTERS ARE NOT WASHABLE.
If the lights do not come on, the problem is with the power
board or Operation Light(s). If you are unable to correct any
of the above problems, call 1-800-267-8305.
TECHNICAL DATA
CABINET
1. Turn Air Cleaner OFF.
Dimensions
2. A soft, damp, lint-free cloth may be used to remove dirt
and fingerprints from painted surfaces, grills and end
panels.
Width
Depth
Height
20.0 in
12.0 in
5.0 in
50.8 cm
30.5 cm
12.7 cm
NEVER USE AN ABRASIVE CLEANER ON THE
CABINET.
Weight
16.0 lbs
7.3 kg
WARNING
Input Voltage
120 V
60 Hz
•
DO
NOT
WASH
COLLECTING
CELL
IN
Power Consumption
(maximum)
85 Watts
DISHWASHER.
•
Never use any object to clean between the cell plates as
this may cause damage to the plates or ionizing wires.
Air Flow
High
Medium
Low
130 cfm
80 cfm
60 cfm
221 m³/hr
136 m³/hr
102 m³/hr
•
•
Never place the cell in an oven to dry.
The edges of the cell may be sharp — handle with care.
Cell Output Voltage
6500 VDC @ < 1 mA
Collecting Cell
Surface
756 in²
4877 cm²
Negative Ionizer
-5000 VDC @ <.1 mA
2 x 327.7 K/in³
DAX Detergent, No. 32921,
and the Activated Carbon
Odour & Gas (VOC) Removal
Filter, No. 32711, are
available from your Sears
outlet.
Negative Ion Output
2 x 20 K/cm³
29.5 m²
Ideal for rooms up to:
(1 room air change
every 20 minutes for
maximum room size)
320 ft²
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFEGUARDS
Safety points you should know about your Electronic Air Cleaner and Ionizer.
Caution:
** Read Owner’s Manual and safeguards before using
** Save Owner’s Manual for later use
** Follow all warnings and instructions marked on Air Cleaner
FOR YOUR PERSONAL SAFETY
1. The Air Cleaner is equipped with a grounded plug. Do not
If liquid has been spilled into the Air Cleaner, unplug the unit
from the wall outlet and refer servicing to qualified service
personnel.
defeat the purpose of this plug by removing the grounding pin,
as this may result in an electrical shock or create an unsafe
condition.
10. Do not use the Air Cleaner near open fire or flame, or sources
of heat i.e. fireplaces, wood burning stoves, kerosene heaters,
stove tops, ovens, etc.
2. When the power cord or plug is damaged or frayed, unplug the
Air Cleaner from the wall outlet and refer servicing to qualified
service personnel.
11. Do not use the Air Cleaner on soft surfaces i.e. beds, sofas.
3. Do not overload wall outlets and extension cords, as this can
result in fire or electric shock.
12. Do not use the Air Cleaner when oxygen is being used or when
combustible gases are present.
4. Do not allow anything to rest on or roll over the power cord, and
do not place the unit where power cord is subject to traffic or
abuse. This may result in a shock or fire hazard.
13. The Air Cleaner has slots or openings in the cabinet for
ventilation purposes, to provide reliable operation of the unit,
and to protect it from overheating. These openings must not be
blocked or covered.
5. Do not attempt to service the Air Cleaner yourself as opening or
removing switch cover may expose you to dangerous voltage or
other hazards. Refer all servicing to qualified personnel.
14. The Air Cleaner should be operated only from the type of power
source indicated on the rating label. If you are not sure of the
type of power supply at your home, consult your local power
company.
6. Never push objects of any kind into the Air Cleaner through
cabinet slots, as they may touch dangerous voltage points, or
short out parts that could result in a fire or electric shock.
15. It is normal for the Air Cleaner to make occasional snapping or
popping sounds, particularly when being turned on after
washing. If the snapping or popping is continuous or frequent,
unplug the unit and call 1-800-267-8305.
7. If the Air Cleaner has been dropped or the cabinet has been
damaged, unplug the unit from the wall outlet and refer
servicing to qualified service personnel.
8. Unplug the Air Cleaner from the wall outlet before cleaning. Do
not use liquid cleaners or aerosol cleaners on cabinet. Use a
damp, lint-free cloth for cleaning, except when cleaning the cell.
16. If the Air Cleaner does not operate normally by following the
operating instructions, unplug the unit from the wall outlet and
refer servicing to qualified service personnel.
9. Do not use the Air Cleaner near water, i.e. near a bathtub, sink,
laundry tub, in a wet basement, in the rain or near a swimming
pool, etc.
LIMITED ONE YEAR WARRANTY
Your Electronic Air Cleaner is guaranteed for one (1) full year from the date of original purchase, against electrical and mechanical defects in
material and workmanship, under normal use and maintenance, which will be repaired or replaced without charge, upon inspection by an
authorized service center. The warranty does not include the Prefilter or Carbon Filter.
This guarantee is in lieu of any other warranty, either expressed or implied.
SEARS CANADA INC. will not be responsible for:
1. Normal maintenance including cleaning or replacement of filters, as outlined in the Owner’s Manual.
2. Damage or repairs needed as a consequence of any misuse, negligent handling, improper servicing, unauthorized alteration, improper
operations or use on voltage other than that stamped on the Air Cleaner.
3. Any personal injury, property damage, or any incidental or consequential damages of any kind, resulting from defects, malfunctions,
misuse, or alteration of the product.
4. Damage as a result of floods, winds, fires, lightning, accidents, corrosive atmosphere, or other conditions beyond the control of Sears
Canada Inc.
5. Parts, including filters not supplied or designated by Sears Canada Inc.
If warranty service is required, take the Electronic Air Cleaner into the nearest Sears outlet or Sears Parts & Service Center, with a proof of
purchase. The original carton and packaging must be used. If not, and if goods arrive damaged due to improper packaging, warranty will be
void.
For more information, call Toll Free 1-800-267-8305
32701.pub
05/06
Download from Www.Somanuals.com. All Manuals Search And Download.
|