Kathrein Satellite TV System MFK 16 User Manual

Operating Manual  
DVB-T Meter  
MFK 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Preface  
Contents  
General information  
Product package  
Safety instructions – important notes  
Charging the battery  
Charging using the AC battery charger leads  
Getting started  
Switching on the meter  
Selecting a region  
Selecting the channels  
Selecting different measuring methods  
Switching off the meter  
Selecting setup mode  
Changing the settings  
Quitting setup mode  
Technical data  
14  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
General information  
The MFK 16 DVB-T signal meter meets the highest quality standards based on its  
design and highly reliable workmanship. DVB-T signals can easily be measured, as  
the spectrum is not relevant and there is no need to see a picture on the screen. Also,  
the signal levels of adjacent analogue channels can be represented with the MFK 16.  
Additionally, it provides a standard list of all VHF/UHF channels.  
This manual tells you how to select the broadcasters covering the individual regions and  
all the stations they provide.  
The manual features the latest available information. You can find the very latest  
information and updates on the Internet at  
“www.kathrein.de”.  
We will in future be making additional region lists available by way of software  
updates.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Product package  
MFK 16 signal meter with integral battery, protective bag and carrying strap  
The MFK 16 product package includes:  
- MFK 16 signal meter,  
- operating manual,  
- leather protective bag,  
- one BNC/IEC adapter,  
- one BNC/F adapter,  
- two 10 dB attenuators,  
- IEC/IEC measuring cable,  
- vehicle battery charger lead,  
- mains power cable and  
- a computer interface cable for programming.  
The mains power cable should be the right one for your region. If it is not, the correct one  
can be obtained from Kathrein or from a local dealer/importer.  
Please keep the original packaging for possible returns.  
WARNING:Thecarryingstrapmaycausestrangulation.Useitonlyincircumstances  
where they is no possibility of slipping or tripping.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Safety instructions – important notes  
This page contains important information on operating and connecting up the unit.  
Read these instructions carefully before setting up the unit.  
Mains power cable  
Make sure that the mains power cable (power supply cable) is not damaged. Units with damaged power  
cables must be disconnected from the mains power (by pulling the mains plug) and be replaced by a qualified  
electrician prior to restarting. Use only the power cable supplied!  
Risk of death due to electric shock!  
DANGER!  
Cleaning  
Pull the mains plug before cleaning the unit. Only use a dry cloth for cleaning and only clean the outer surface.  
Never open the unit.  
Touching the parts inside the unit carries a risk of death due to electric shock!  
Playing children  
Ensure that children do not touch any parts inside the unit.  
Risk of death due to electric shock!  
Mains voltage  
Only operate the unit at the specified mains voltage (indicated on the underside of the unit)!  
If the mains voltage is too high, there is a risk of fire!  
Repairs  
WARNING!  
Ensure that any repairsto your unit are only carried out by qualified personnel. If you open the unit and attempt  
to repair it yourself any warranty claims will be voided!  
Improper intervention into the unit may place at risk its electrical safety.  
The manufacturer shall accept no liability for accidents suffered by the user after opening the unit!  
Connections  
Incorrect wiring of the connections can lead to malfunctions or defects in the unit!  
Long periods of absence / storms  
Always disconnect the unit from the mains power by pulling the plug if you are going to be away for a lengthy  
period of time or in a storm.  
ATTENTION!  
Damp, sunlight, heat  
The unit should be protected from damp, dripping water and splashing. Do not place the unit close to the  
heating or expose it to direct sunlight and do not operate it in damp locations.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Safety instructions – important notes  
• When operated from the mains there is danger to life if the unit is not handled correctly  
• Do not expose the unit to dripping or splashing water  
• Do not operate the unit in extreme climatic conditions at high humidity levels  
• Do not place any containers filled with liquid on the unit  
• Keep open flames away from the unit. Do not place lit candles or such like on the unit  
Regulation use  
The operator must ensure that  
• the meter is used only in accordance with its designated purpose  
• the meter is operated only if in perfect workingorder  
Mechanical durability  
The MFK 16 is designed for mobile use and for the mechanical stresses and strains occurring in such  
use. The MFK 16 must not be exposed to severe mechanical stress, such as bumping, knocking or  
dropping, as this may damage it.  
The environment  
This meter includes a NiMH battery. The battery must not be disposed of in normal domestic waste.  
Take it to a designated collection point for used batteries.  
Electronic equipment is not household waste. In accordance with directive 2002/96/EC OF THE  
EUROPEAN PARLIAMENTAND THE COUNCILof 27th January 2003 on used electrical and electronic  
equipment, it must be disposed of properly.  
At the end of its service life, take this unit for disposal at a designated public collection point.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Charging the battery  
When shipped, the battery is not charged. We recommend you leave the battery on  
charge for 24 hours before using it for the first time, so that it is fully charged and the  
state of charge of the cells is equalised. This recommendation also applies if the unit has  
not been used for a lengthy period of time.  
The battery must occasionally be recharged, even if the meter has not been in use. After  
the battery has been disconnected from the mains power and then reconnected, the  
battery charge indicator shows 0 %. The correct state of charge is only indicated once  
it has been charged again.  
It makes no difference whether you charge the unit from the mains or in a vehicle.  
PLEASE NOTE that it is not possible to use the MFK 16 while it is charging.  
Charging from the built-in power supply unit  
Open the flap on the rear of the MFK 16 to expose the mains power socket. Insert the  
mains power cable into the socket and plug the other end into a wall socket. The battery  
is fully charged when the display of the MFK 16 shows “Trickle Charge”.  
Charging in a vehicle (DC vehicle battery charger leads)  
The 12 Volt power socket (12 V DC) is on the right-hand side of the unit. Insert the DC  
vehicle battery charger lead into the socket and plug the other end into the vehicle‘s  
cigarette lighter. Note that in some vehicles the cigarette lighter only carries power when  
the ignition is switched on.  
Only the supplied vehicle battery charger lead may be used to charge the unit in the  
vehicle. Using any other cable may damage the meter and void any warranty claim.  
The MFK 16 can be left connected to any of the charging sources mentioned for a lengthy  
period of time in “Trickle Charge” mode without damaging the internal components or  
the battery.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Getting started  
Switching on the meter  
Connect the MFK 16 input on the front of the unit by a BNC cable to the antenna.  
Alternatively, you can use the BNC/IEC, the BNC/F adapter and the standard antenna  
cable (IEC).  
Press and  
hold for 5  
seconds  
The display first shows the version number and the battery state of charge. The meter  
automatically switches to the next display readout.  
Region  
Channel no.  
Battery charge  
Signal level (RF level) as bar indicator in range 25 to 75 dBμV with over/under range  
indicator.  
The second display readout indicates:  
- the last region selected,  
- the channel number,  
- the received HF level in dBμV as a bar indicator,  
- the battery state of charge.  
Selecting a region  
The factory pre-programmed regions enable users to scroll through the channels  
in their respective region. This means both analogue (in RF level mode) and digital  
transmissions (in BER mode) can be detected. Each region has more than one  
transmission channel. Each channel is designated as a MUX (multiplexer). Each MUX  
transmits multiple stations.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Getting started  
To find the regions you want, scroll through the stored list. To switch regions, press and  
hold down the right or left arrow button for about 5 seconds.  
The meter is factory pre-programmed with the following German regions:  
Berlin VHF  
Berlin UHF  
Bremen/Unterweser  
Düsseldorf  
Frankfurt VHF  
Frankfurt UHF  
Hamburg/Lübeck VHF  
Hamburg/Lübeck UHF  
Hanover/Braunschweig VHF  
Hanover/Braunschweig UHF  
Kiel VHF  
Kiel UHF  
Cologne/Bonn  
Munich VHF  
Munich UHF  
Nuremberg VHF  
Nuremberg UHF  
All VHF channels 5-12  
All UHF channels 21-69  
Additional region lists can be obtained as required from the Kathrein website  
“www.kathrein.de”.  
Selecting the individual channels  
Press and hold down the right or left arrow button for less than 5 seconds to select the  
various channels.  
Selecting different measuring methods  
The meter is able to measure the RF signal level (analogue and digital channels),  
“BER” (Bit Error Rate) as a bar indicator for “Pre BER” and as a numeric value for “Post  
VITERBI BER”. The “BER” can only be measured on digital channels.  
Press the “ON” button to toggle between “RF” and “BER” mode.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Getting started  
Aligning an antenna / BER mode  
Note:  
If neither a bar nor DVB-T appears on the display, the signal is too low or the transmission  
is analogue.  
Real-time Pre BER bar  
indicator  
Carrier-to-noise  
(C/N) ratio in dB  
Select a channel and BER mode. For the best result, check each channel in the selected  
region and set it to the best reception quality, e.g. a peak value on the bar indicator  
(PRE BER).  
4 Quality stars  
*
**  
***  
****  
< 2E-4  
< 2E-5  
< 2E-6  
< 2E-7  
Active 5V antenna switched on  
After about 10 seconds the display shows the “Post VITERBI BER” as a numeric value  
and the quality stars depending on the reception quality.  
A BER of 2E-6 or less together with 3 stars (***) is required for satisfactory  
reception.  
Check ALL channels for optimum reception quality, e.g. signal peaks for the weakest  
channel.  
HF level mode  
In RF level mode, the meter displays the signal level in dBμV. For levels below 25 dBμV  
the under-range icon appears on the display.  
If the meter has captured a digital carrier signal, “DVB-T” is displayed. To make this  
clear, the acoustic signal changes pitch. If the 75 dBμV level is exceeded, an over-range  
icon is displayed. In this case the supplied attenuator must be inserted into the antenna  
lead (adding the 10 dB to the level then measured).  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Getting started  
Switching off the meter  
To switch off the MFK 16, press and hold down the “OFF” button for about 5 seconds.  
The display shows “Power off”, then goes blank.  
Selecting setup mode  
The arrow indicates the selected function.  
Quit  
Ant off  
Backlight on  
Click off  
To select setup mode, with the unit switched off press and hold down the “OFF” button  
for about 5 seconds.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Getting started  
Changing the settings  
Timer for automatic power-off selected.  
Click on  
Rest 6Min  
Defaults  
German  
Press the Up or Down button (ON/OFF) to select the required function.  
Press the left or right arrow button to change a function.  
The cursor indicates the selected function. Press the left or right arrow button to make  
changes. The display shows the status of the function.  
The following functions are available in setup mode:  
1. Power supply antenna ON/OFF, e.g. 5 V DC for active antenna  
2. Backlighting ON/OFF  
3. Acoustic signal on button press ON/OFF  
4. “Rest time” (timer for automatic power-off) 0 to 20 minutes, or “Always on”  
5. “Defaults”. Resets the meter (except for language setup)  
6. Languages: German, English, French, Italian and Spanish  
Quitting setup mode  
Quit  
Ant off  
Backlight on  
Click off  
Keep pressing the Up button (OFF) until the cursor is positioned on “Quit” and then  
press the right arrow button.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Technical data  
• Display of signal levels of terrestrial signals  
• Display of carrier-to-noise (C/N) ratio  
• BER measurement pre and post Viterbi  
• Memory for 32 different frequency lists  
• 10 frequency lists (City lists) for the individual regions and two master lists  
(VHF 5-12; UHF 21-69) pre-programmed  
• Problem-free adaptation and modification of frequency lists by software update  
via RS 232 serial interface  
• Demodulation: COFDM, 2k and 8k mode  
• Channel bandwidth: 7 and 8 MHz measurable  
• RF input range: VHF (Band 3) 167-230 MHz and UHF 470-862 MHz  
)
• RF input level range: 35 to 75 dBµV *  
• RF input socket: BNC 75 Ohm  
• Remote feed (5 V, 150 mA) to active antennas possible via RF input  
• Power supply via built-in NiMH battery 2.4 A/7.2 V  
• Battery capacity for more than 6 hours continuous duty  
• Internal power pack for 100 to 240 VAC  
• External 12 V DC supply  
• Dimensions, L x H x W (mm): 168 x 58 x 123  
• Weight: 0.810 kg  
)
* For higher levels the supplied attenuators must be used.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
KATHREIN-Werke KG • Phone +49 8031 184-0 • Fax +49 8031 184-306  
Anton-Kathrein-Straße 1 – 3 • P.O. Box 10 04 44 • 83004 Rosenheim GERMANY  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Insignia Stereo Receiver NS VS314 NS VS314 C User Manual
IRiver MP3 Player H140 User Manual
JL Audio Car Speaker M 770x User Manual
JVC DVD Player HR XVC11BJ User Manual
JVC Security Camera DZ VCA3U User Manual
Kambrook Blender KB815B User Manual
Kenmore Washer Dryer 3405594 User Manual
KitchenAid Indoor Furnishings KKFV01LPCR User Manual
Knoll Systems Projection Television HD177 User Manual
Kramer Electronics Printer VS 84H User Manual