Kathrein Car Amplifier VGF 9030 9040 User Manual

Compact amplifier  
s
VGP 9033-1G/9041  
VGF 9030/9040  
VGO 939-1G/VGF 939-1G  
VOS 952-1G/953-1G  
Antennen · Electronic  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VGP 9033-1G/9041  
VGF 9030/9040  
CONTENTS  
DESCRIPTION  
The compact amplifiers with  
electronic tuning elements –  
VGP 9033-1G/9041 and VGF 9030/9040  
VGP 9033-1G/9041 – VGF 9030/9040  
• Modern, monitorable compact amplifiers for inter-  
active HFC networks  
V
GP 9033-1G/9041-VGF 9030/9040  
• Innovative operational concept: Using electronic  
tuning elements, set using HTE 10 hand-held unit  
(fewer plug-in cards and attenuation pads  
required, repeatable device settings)  
• Integrated frequency-agile 2-pilot control in  
VGP 9033-1G/9041enables quick commissioning:  
- Automatic levelling in the forward path, thus no  
need for time-consuming manual levelling  
- Automatic presetting of the return path is  
possible  
• Remote configuration of all setting parameters via  
monitoring system (can be activated/deactivated)  
• High gain (up to 40 dB), variable in interstage  
position  
With the VGP 9033-1G/9041 and VGF 9030/9040  
Kathrein offers a latest-generation compact amplifier  
series. A wide range of settings, electronic opera-  
tion and excellent technical data – at an unbeatable  
price/performance ratio.  
Product description  
Page 3  
Details, Block diagram, Accessories  
Technical Data  
Page 4-5  
Page 6  
VGO 939-1G/VGF 939-1G  
"Plug-and-Play" redefined  
Product description  
Page 7  
Electronic setting of all important parameters, automatic  
levelling (only for VGP 9033-1G/9041) as well as remote  
configuration via HMS or DOCSIS monitoring ensure  
the shortest start-up and maintenance times. The copy  
function enables one to copy all settings and transfer  
them to another device at the press of a button.  
The absence of plug-in cards for gain and slope  
not only accelerates start-up, but also simplifies  
logistics and saves warehousing costs.  
Details, Block diagram, Accessories  
Technical data  
Page 8-9  
Page 10  
• Latest GaAs-MMIC technology  
• Very high output levels at lowest intermodulation  
products, even for interstage operation  
• Loop-through input (only for VGP 9033-1G/9041)  
and output splitter can be configured  
• De-emphasis (inverse-equalisation) insert position  
• Remote feeding: 7 A per input/output,  
local feeding: 10 A  
VOS 952-1G/953-1G  
Another advantage during modifications:  
new values are taken over without any interruptions.  
Multimedia services remain undisturbed.  
Product description  
Page 11  
Details, Block diagram, Accessories  
Technical data  
Page 12-13  
Page 14-15  
• Insert position for monitoring transponder  
(HMS/DOCSIS)  
Test sockets on input/output and in return path  
amplifier  
• Integrated return path amplifier, settable gain  
• Ingress Control Switch  
• Aluminium die-cast housing with  
PG 11 connections  
Start-up without a measuring instrument  
– it doesn't get any easier than this  
Accessories  
Due to automatic levelling, the compact amplifiers  
VGP 9033/9041 can be put into operation  
with just a few steps:  
TVM 850/H, TVM 1000  
HTE 10  
Page 16  
Page 17  
- Simply enter the desired output level for the  
lower and upper pilot frequency and start  
levelling  
Splitters, Taps, Equalisers  
Connectors  
Page 18-19  
Page 20  
- After a few seconds, the device automatically  
sets the desired values, whereby optimal technical  
data are continuously reached.  
Manual vernier adjustment is still possible at any time.  
- Subsequently, automatic presetting can also  
be effected in the return path.  
- For the next devices, levelling runs even more  
quickly. The copy function enables desired  
settings to be automatically incorporated.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
VGP 9033-1G/9041  
VGF 9030/9040  
DETAILS, ACCESSORIES, BLOCK DIAGRAM, DELIVERY STATUS  
Insert position for monitoring  
transponder  
Insert position "Forward 2"  
(not included in delivery scope)  
Connection socket for  
hand-held unit HTE 10  
Insert position "Forward 1"  
e.g. for additional C-line  
pre-emphasis  
F-type test socket  
internal (-20 dB)  
Image: VGP 9033-1G/9041  
Delivery status  
• EAC 93-1G (Order no. 24510115): Tap (3/6 dB)  
• EAC 90-1G (Order no. 24510116): Tap (1.5/10 dB)  
• EAC 94-1G (Order no. 24510114): Tap (0.8/20 dB)  
• Note: The input and output plug-in positions  
must each be equipped with a EBC/EAC xx  
for operation. The other plug-in positions are  
already equipped with null cards  
• Input and output cable fittings not included  
in the delivery scope (see page 20)  
• Please note that the VGF 9030/9040 does  
not include remote-feed fuses in its delivery  
scope (see page 20)  
• ERC 22  
(Order no. 24510085):  
C-line pre-emphasis equaliser for  
VGP 9041/VGF 9040  
• ERZ 630  
• ERS 800  
• ERD 810  
• ERD 813  
• ERD 814  
(Order no. 24510108):  
Equaliser 630 MHz  
(Order no. 24510109):  
System equaliser 862 MHz  
(Order no. 24510110): De-emphasis  
equaliser switchable, 862 MHz  
(Order no. 24510117):  
F-type  
test socket  
internal  
Image: VGP 9033-1G/9041  
(-20 dB)  
De-emphasis equaliser  
(Order no. 24510120): Attenuation pad  
F-type broadband input  
for the return path with  
protective cap (-10 dB)  
• TVM 850/H (Order no. 26210077):  
Monitoring transponder HMS  
(5-24 MHz), frequency-agile  
• TVM 1000 (Order no. 26210086):  
Monitoring transponder DOCSIS  
Input insert position  
Accessories  
• EBC 01E-1G (Order no. 24510121): Null card input  
• EBC 00-1G (Order no. 24510119): Null card output,  
for operation with one output  
Output insert position  
• FUN 15  
(Order no. 25010017):  
FUN remote-feed fuse 15A/125 VDC  
(Order no. 25010005): Hand-held unit  
• EBC 90-1G (Order no. 24510113): Splitter  
(2 outputs symmetrical)  
• HTE 10  
4
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
For details see pages 16-20  
VGO 939-1G/  
VGF 939-1G  
VGP 9033-1G/9041  
VGF 9030/9040  
Technical Data  
DESCRIPTION  
DATA  
Type  
VGF 9030  
VGF 9040  
VGP 9033-1G  
VGP 9041  
VGO 939-1G/VGF 939-1G  
The compact amplifier with  
slide switches –  
VGO 939-1G/VGF 939-1G  
Order no.  
24410108  
24410109  
24410103  
24410054  
• Latest GaAs-MMIC technology  
• Innovative operational concept:  
- Settings via slide switches  
- Device settings can be reproduced exactly  
- Fewer plug-in cards and variable attenuators  
needed  
• Integrated diplexers allow optimised data  
• Very high output level at lowest intermodulation  
products (also for interstage attenuation)  
• Pluggable loop-through output  
• One or two output(s) configurable  
• Built-in active return path with various setting  
possibilities  
• Return path can also be operated passively  
• 15 MHz high pass can be activated in the  
return path  
• Ingress Control Switch (ICS)  
• Monitorable with HMS or DOCSIS transponder  
(option)  
• Insert position for additional functions in the  
forward path (e.g. de-emphasis)  
• Bi-directional test socket on the amplifier input  
• Directional coupler test socket on amplifier output  
and in return path  
Test signals can be coupled in for the return path  
• LED as function indicator  
• Highly efficient switched-mode power supply unit  
• Advanced remote power concept in the  
VGF 939-1G:  
- Newly developed remote feed coils  
- Remote feed current: Max. 7 A per connec-  
tion, local insertion max. 10 A totally  
- Remote feeding possibilities: By choice via  
all RF connections or local connector  
(power passing)  
FORWARD PATH  
Frequency range  
MHz  
dB  
85-862  
33  
85-862  
40  
85-1000  
33  
85-862  
40  
In addition to the devices with electronic setting,  
Kathrein offers yet another highly innovative  
compact amplifier platform. This particularly  
economical series requires no equaliser cards  
or attenuation pads. All adjustments can be easily  
carried out using slide switches.  
Gain (at 1000 MHz)  
Return loss  
dB  
19-1.5 dB/oct.  
Frequency response (85-1000 MHz at 25 °C)  
Max. output level according to CENELEC 1) - CTB > 60 dB  
Max. output level to CENELEC 1) - CSO > 60 dB  
dB  
0.5  
114  
116  
dBµV  
dBµV  
dB  
5)  
Attenuation range, electronically settable in 0.5 dB steps  
0-16  
0-15  
0-15  
0-5  
0-16  
0-20  
-
5)  
Slope range, electronically settable in 0.5 dB steps  
dB  
0-20  
Simple, yet effective  
Interstage attenuation, settable in 1 dB steps  
Interstage pre-emphasis, electronically settable in 2.5 dB steps  
Noise figure at minimum pre-emphasis  
Adjustment range, sloped at 85 MHz  
-
dB  
dB  
2-9  
2,5-10  
6.5  
2-9  
6
The required attenuation and slope values are  
set with a combination of several slide switches.  
The advantages are obvious. Besides saving  
plug-in cards, this allows exact reproduction of  
setting values without requiring a measuring  
instrument.  
6
dB  
-
2
3
Adjustment range, parallel  
dB  
-
Frequency range lower pilot Pu ²)  
MHz  
MHz  
dBµV  
dB  
85-230  
570-870  
85-230  
> 67  
82.5-230  
570-870 5)  
)
Frequency range upper pilot Po ²  
Pilot level (PAL/CW/QAM)  
Hum modulation ratio at 7 A  
RETURN PATH  
83-112  
5-65  
Replacement of the device, for example, is thus  
much easier.  
70  
70  
30  
Frequency range  
MHz  
dB  
When slide switches are shifted, a virtually uninter-  
rupted signal flow is guaranteed – multimedia  
services remain undisturbed.  
Gain  
30  
28  
Frequency response at 25 °C  
dB  
0.5  
0.3  
0.5  
6)  
Input level density (CINR = 50 dB), at 28 dB gain  
dBµV/Hz  
dB  
-9  
21  
6)  
Dynamic range: CINR > 50 dB, 5-65 MHz, at 28 dB gain  
7)  
Dynamic range: CINR > 50 dB, 5-65 MHz, at 18 dB gain  
dB  
26  
Maximum reliability  
Noise figure  
dB  
6
Attenuation, switchable in 1 dB steps  
Slope, switchable in 7 steps  
dB  
0-30  
1-8  
The implemented slide switches fulfil the highest  
demands regarding reliability and endurance.  
Dual gold-plated contact reeds, increased  
contact pressure and a separate catch spring  
ensure ultimate reliability of the switches, which  
have been proven and tested 100,000 times.  
dB  
ICS switch (attenuation switchable over EMS or  
HTE 10 hand-held unit)  
dB  
dB  
0/6/> 45  
60  
Hum modulation ratio at 7 A/> 15 MHz  
GENERAL  
Voltage supply  
V AC  
W
30-72  
Power consumption  
21  
23  
• Surge absorber on all RF connections and in  
switched-mode power supply unit  
• Power management: Unused amplifier stage  
switch-off for reduced power consumption  
• Die-cast housing with PG 11 connectors  
• Easy connection of large cable fittings due to  
extended thread distance  
Max. remote feed current per connection  
Max. remote feed current in local feeding (power passing)  
RF connections  
A
7
A
10  
PG 11  
Housing protection category  
Ambient temperature range  
Screening factor  
IP 54  
IP 67  
°C  
-20 to +55  
Conforms to CENELEC EN 50083-2  
2 kV (1.2/50 µs)  
Overvoltage protection acc. to IEC 60-2  
Dimensions (W x H x D)  
• Outdoor operation possible, housing protection  
class: IP 54  
mm  
240 × 95 × 240 3)  
NETWORK MANAGEMENT (optional)  
Test sockets: F-type connectors (internal)  
Operational voltage; current; temperature; electronic tuning elements; pilot setting and  
alarm; automatic levelling of forward path; automatic presetting of return path; return  
path gain; ICS switch; remote inventory data  
Monitorable/settable parameters  
1)  
2)  
6)  
3)  
7)  
4)  
5)  
For VGP 9033-1G in 1 dB steps  
9 dB slope  
Set using HTE 10 hand-held unit  
For VGF 90xx at 30 dB gain  
Width incl. hinges: 267 mm  
For VGF 90xx at 20 dB gain  
As of device version Bxx from 570-870 MHz  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VGO 939-1G/  
VGF 939-1G  
DETAILS, ACCESSORIES, BLOCK DIAGRAM, DELIVERY STATUS  
Input insert position e.g. for  
de-emphasis equaliser  
Insert position for monitoring  
transponder (not supplied)  
Option  
Interstage  
Forward path: Adjustment  
of attenuation and  
equalisation using slide  
switches  
De-emphasis  
4 / 0 / 8 dB  
1 / 0 / 2 dB 3 / 0 / 6 dB  
0 / 10 dB 2 / 0 / 4 dB 6 / 0 / 12 dB 2 / 0 / 4 dB 6 / 0 / 12 dB  
LED (Power supply  
function)n)  
dB  
dB  
dB  
dB  
Pre-emphasis  
Attenuation  
Attenuation  
-20 dB  
Attenuation  
Pre-emphasis  
Attenuation  
or  
pre-emphasis  
Monitoring transponder  
Current  
Temperature  
85 - 1006 MHz  
85 - 1006 MHz  
5 - 65 MHz  
Ub  
ICS  
5 - 65 MHz  
Option  
30 dB  
21 dB  
Switched-off  
4 / 0 / 8 dB  
3 / 0 / 6 dB  
2 / 0 / 4 dB 6 / 0 / 12 dB  
-30 dB  
(Return path:  
= 70 dBµV)  
passive  
dB  
dB  
Attenuation  
dB  
P
nominal  
active  
0 / -8 dB /  
"switched-off"  
Attenuation  
Internal  
5 MHz  
Test 2  
v = 14 dB  
Pre-emphasis  
5-65 MHz  
-20 dB  
Internal  
15 MHz  
Ingress  
detection  
Test 3  
-10 dB  
Internal  
S10  
(Pnom=ina6l0 dBµV)  
Test 1  
-20 dB  
bi-directional  
Return path  
measurement  
or feed-in  
Option  
max. 7 A  
Option  
power passing: 10 A  
32-72 VAC  
Loop through  
splitter field  
SNT  
Output  
splitter field  
C
15 A  
T3,15AL  
A
D
B
E
Output 1  
PG11  
Input  
PG11  
Loop through  
PG11  
Output 2  
PG11  
= slide switches  
A/B/E/D = 15-A fuse  
ERZ 940  
(Order no. 24510059):  
De-emphasis equaliser  
(cable-analogue) 862 MHz,  
7 dB fixed  
(Order no. 24510110):  
De-emphasis equaliser  
(Order no. 24510117):  
De-emphasis equaliser  
Delivery status  
• For operation with one input or output, no  
plug-in cards required  
• All insert positions are fitted with 0-dB  
bridging plugs ex works  
• Input and output cable fittings not included in  
the delivery scope (see page 20)  
Output splitter field  
ERD 810  
ERD 813  
Direct supply to  
device up to  
10 A  
F-type test  
ERD 814  
ERZ 630  
(Order no. 24510120):  
De-emphasis equaliser/attenuator  
(Order no. 24510108):  
Equaliser 47-630 MHz, switchable  
in 2-dB steps from 2-18 dB  
(Order no. 24510109):  
socket for  
the return  
path  
F-type test socket on  
output for return path  
measurement or feed-in  
(-20 dB)  
Accessories  
Splitter field  
loop-through input  
(-10 dB)  
• EBC 90-1G  
(Order no. 24510113)  
Splitter  
ERS 800  
System equaliser 862 MHz  
(2 outputs symmetrical)  
(Order no. 24510115):  
Tap (3/6 dB)  
(Order no. 24510116):  
Tap (1.5/10 dB)  
F-type test  
socket  
bidirectional on  
input (-20 dB)  
TVM 850/H (Order no. 26210077):  
Monitoring transponder HMS  
• EAC 93-1G  
• EAC 90-1G  
• EAC 94-1G  
Return path  
switchable  
passive/active  
(5-42 MHz), frequency-agile  
(Order no. 26210086):  
Monitoring transponder DOCSIS  
Integrated return path  
amplifier, adjustable  
with slide switches  
TVM 1000  
Order no. 24510114):  
Tap (0.8/20 dB)  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
VGO 939-1G/  
VGF 939-1G  
DESCRIPTION  
DATA  
VOS 952-1G/953-1G  
Technical Data  
Type  
VGO 939-1G  
VGF 939-1G  
Notes  
House connection amplifiers  
VOS 952-1G/953-1G  
Order no.  
24410101  
Locally fed  
24410100  
Remotely fed  
• Latest GaAs-MMIC technology  
• Innovative operational concept:  
- Settings via slide switches  
- Device settings can be reproduced exactly  
- Fewer plug-in cards and variable attenuators  
needed  
The compact, price-optimised house connection  
amplifiers 952-1G and VOS 953-1G were designed  
for application in modern HFC networks. Great value  
was set upon a high dynamic range for Interstage  
operation as well as upon a cost-efficient operation  
concept with slide switches.  
FORWARD PATH  
Frequency range  
MHz  
dB  
85-1000  
Gain  
40  
32-40  
Gain setting range, interstage ³)  
Amplitude response  
dB  
dB  
0.5  
85-1000 MHz, at 25 °C  
at 25 °C  
Amplitude response (additional, 862-1000 MHz)  
dB  
-0.5  
• Very high output level at lowest intermodula-  
tion products  
• Built-in active return path with various setting  
possibilities  
• 15 MHz high pass can be activated in the  
return path  
• Ingress Control Switch (ICS)  
• Monitorable with HMS or DOCSIS (option)  
• Insert position for additional functions in the  
forward path (e.g. de-emphasis)  
• Bi-directional test socket on amplifier input  
with inductive coupling  
• Directional coupler test socket on amplifier  
output and in return path  
Test signals can be coupled in for the return  
path  
• Highly efficient switched-mode power supply  
unit  
• VOS 952-1G - locally fed, F-type connectors  
• VOS 953-1G - remotely fed (auto-supply),  
F-type sockets  
• Surge absorbers on all RF connections and in  
switched-mode power supply unit  
• Die-cast housing  
³)  
Attenuation setting range, on input  
dB  
0-26  
³)  
Pre-emphasis setting range, at input or interstage  
dB  
0-26 or 0/4/8  
18-1.5/oct.  
4
Monitoring via DOCSIS transponder  
Return loss, as of 40 MHz  
Noise figure  
dB  
dB  
at 40 dB gain  
If fitted with the optional monitoring transponder  
TVM 1000/H, the amplifiers VOS 952-1G/953-1G  
can be monitored via DOCSIS protocol. Monitoring  
with HMS Both amplifiers can be flexibly integrated  
into monitoring systems which operate with the  
widespread HMS protocol.  
¹)  
Max. operational level: CENELEC raster  
dBµV  
dB  
116/118  
CTB: 60 dB/CSO: 60 dB (pre-emphasis 4 dB)  
AT 7 A, 5-65/85-1000 MHz  
Hum modulation ratio  
-
60/70  
RETURN PATH  
Frequency range  
MHz  
dB  
5-65  
Gain (input stage bridged), active operation  
Gain, passive operation  
30 (21)  
dB  
-2  
Amplitude response  
dB  
0.5  
Attenuation setting range, at input or interstage ³)  
Pre-emphasis setting range, interstage  
Ingress Control Switch (ICS)  
Max. output level at 30 and 21 dB gain  
Max. output level  
dB  
0/4/8 or 0-16  
Bridgeable diplex filter  
dB  
0/3/6  
8/> 40  
107/116  
120  
dB  
attenuated/switched-off  
Bridging plugs enable variation of the frequency  
range between 47-1000 MHz and 85-1000 MHz  
making it possible to carry out transmission in  
BAND I in the forward path (without return path).  
dBµV  
dBµV  
dBµV/Hz  
dB  
60 dB IMod2/IMod3 (EN 60728-3/50083-5)  
According to KDG 1 TS 140 (full system load)  
CINR at 50 dB (EN 60728-3/item 4.7)  
Input level density  
-8  
Dynamic range at 30 dB gain (5-65 MHz) ²)  
Dynamic range at 21 dB gain (5-65 MHz) ²)  
Noise figure  
18  
dB  
25  
dB  
6
Flexible return path  
NETWORK MANAGEMENT  
Internal voltage supply, internal current drain,  
internal temperature, ICS switch  
Monitorable parameters  
In the latest generation, the  
return path can be  
operated either actively or passively.  
Test sockets  
Test socket 1 (on amplifier input), bi-directional  
dB  
dB  
dB  
20  
20  
10  
Possibility to feed in return path signals  
(5-65 MHz); if button is kept pressed, the  
incoming return path signal can be measured  
Test socket 2 (on amplifier output), directional coupler  
Test sockets: F-type sockets  
Test socket 3 (in return path amplifier), directional coupler  
SWITCHED-MODE POWER SUPPLY  
Nominal input voltage  
Attenuation relative to return path input  
V AC  
Hz  
A
230  
32-72  
Mains frequency range  
50-60  
17.5  
Max. remote feed current  
-
-
7
per input or output  
Max. remote feed current, local insertion  
Power consumption (without monitoring)  
GENERAL  
A
10  
W
Return path amplifier active  
Classification according to KDG 1 TS 140  
Ambient temperature range  
RF connections  
D(4.4)  
-20 to +55  
PG 11  
°C  
data-conform operation  
Test sockets  
F-type connector  
IP 54  
Housing protection class (to EN 60529)  
Dimensions (W x H x D)  
mm  
238 × 86 × 189  
1(10)/2.2  
3)  
Settable in 2-dB steps using slide switches  
Packing unit/weight  
pc./kg  
11  
1)  
2)  
When the 15 MHz high pass is connected, the dynamic range increases by 3 dB  
CENELEC: 41 channels  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DETAILS, ACCESSORIES, BLOCK DIAGRAM, DELIVERY STATUS  
VOS 952-1G/953-1G  
Insert position for  
monitoring transponder  
(not included in delivery scope)  
Input insert position e.g.  
for de-emphasis equaliser  
Forward path:  
Adjustment of  
attenuation and  
equalisation using  
slide switches  
LED (Power  
supply function))  
Delivery status  
Accessories  
• ERZ 940  
(Order no. 24510059):  
De-emphasis equaliser  
• The insert position is fitted with a  
0-dB bridging plug ex works  
(cable-analogue) 862 MHz, 7 dB fixed  
(Order no. 24510108): Equaliser  
47-630 MHz, 2-18 dB in 2-dB steps  
(Order no. 24510109):  
System equaliser 862 MHz  
(Order no. 24510110):  
F-type test socket  
on output  
for return path  
measurement or  
feed-in (-20 dB)  
• ERZ 630  
• ERS 800  
• ERD 810  
Return path  
switchable  
passive/active  
F-type test socket  
bidirectional on input (-20 dB)  
De-emphasis equaliser,  
switchable 3 dB  
• TVM 850/H Order no. 26210077):  
Monitoring transponder HMS  
F-type test socket for the return path  
(-10 dB)  
Integrated return path  
amplifier, adjustable  
with slide switches  
protocol (frequency-agile)  
• TVM 1000  
(Order no. 26210086): Monitoring  
transponder DOCSIS protocol  
12  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VOS 952-1G/953-1G  
DATA  
Technical Data  
Type  
VOS 952-1G  
24410098  
VOS 953-1G  
24410099  
Notes  
Type  
VOS 952-1G  
24410098  
VOS 953-1G  
24410099  
Notes  
Order no.  
Order no.  
Locally fed  
Remotely fed  
Locally fed  
Remotely fed  
SWITCHED-MODE POWER SUPPLY  
Nominal input voltage  
FORWARD PATH  
Frequency range  
V AC  
Hz  
230  
38-65  
50-60  
MHz  
dB  
47/85-1000  
40-32  
47/85-1000  
40-32  
¹)  
Mains frequency range  
50-60  
Gain  
Interstage gain setting  
85-1000 MHz, at 25 °C  
Return path amplifier active/  
without monitoring  
Amplitude response  
dB  
0.5  
0.5  
Power consumption  
W
11  
12  
Amplitude response (additional,  
862-1000 MHz)  
dB  
dB  
-0.5  
0-16  
-0.5  
0-16  
at 25 °C  
GENERAL  
Attenuation setting range  
On amplifier input  
Ambient temperature range  
RF connections  
Test sockets  
°C  
-20 to +55  
F-type socket  
F-type socket  
-20 to +55  
F-type socket  
F-type socket  
On amplifier input  
and interstage  
Pre-emphasis setting range  
dB  
0-16 and 0/6  
4/5/5  
0-16 and 0/6  
4/5/5  
Noise figure  
dB  
At 40/36/32 dB gain  
IP 54: Outdoor use in weather-  
proof cabinet  
Housing protection class (to EN 60529)  
IP 54  
IP 54  
Max. operational level: CENELEC channel  
CTB: 60 dB/CSO: 60 dB (pre-  
emphasis 6 dB and gain 40 dB)  
dBµV  
dB  
112/116  
-
112/116  
>60/70  
²)  
plan  
Dimensions (W x H x D)  
Packing unit/weight  
mm  
225 × 55 × 155  
1(10)/1.8  
225 × 55 × 155  
1(10)/1.8  
Hum modulation ratio  
RETURN PATH  
pc./kg  
Frequency range  
MHz  
dB  
5-65  
30/21  
5-65  
30/21  
1) Adjustable with 2 slide switches in 1 dB steps  
2) CENELEC: 42 channels  
3) When the 15 MHz high pass is connected, the dynamic range increases by 3 dB  
Gain, switchable  
Frequency response  
Attenuation setting range  
Pre-emphasis setting range  
Ingress Control Switch (ICS)  
dB  
0.5  
0.5  
dB  
0-16 / 0/4/8  
0/3/6  
0-16 / 0/4/8  
0/3/6  
On input/interstage  
Interstage  
dB  
dB  
8/> 40  
8/> 40  
attenuated/switched-off  
60 dB IM2/IM3  
(EN 60728-3/50083-5)  
Max. output level at 30 and 21 dB gain  
Maximum output level  
dBµV  
dBµV  
107/116  
120  
107/116  
120  
According to KDG 1 TS 140  
(medium system load)  
CINR at 50 dB (EN 60728-3/  
item 4.7)  
Input level density  
dBµV/Hz  
-10  
-10  
Dynamic range at 30 dB gain (5-65 MHz) ³)  
Dynamic range at 21 dB gain (5-65 MHz) ³)  
Noise figure  
dB  
dB  
dB  
17  
25  
5
17  
25  
5
NETWORK MANAGEMENT  
Internal supply voltage,  
internal current drain,  
Internal supply voltage,  
internal current drain,  
Monitorable parameters  
temperature, ICS switch temperature, ICS switch  
TEST SOCKETS  
5-862 MHz bi-directional,  
internal  
Test socket 1 (on amplifier input)  
dB  
dB  
dB  
20  
20  
10  
20  
20  
10  
5-862 MHz with directional  
coupler, external - return path  
signals can be fed in (5-65  
MHz); if push-button is kept  
pressed, the incoming return  
path signal can be measured  
Test socket 2 (on amplifier output)  
Test socket 3 (in return path)  
5-65 MHz with directional  
coupler, external  
14  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Accessories  
HTE 10 - Hand-held unit  
Monitoring transponder HMS protocol,  
frequency-agile  
• Monitoring transponder for compact amplifiers, house connec-  
tion amplifiers and optical compact receivers (see table)  
• Monitors various parameters such as voltage, current drain and  
internal temperature  
• Controls the Ingress Control switch in correspondingly equip-  
ped devices  
With the HTE 10 hand-held unit one is able to adjust  
correspondingly equipped devices on site. Using the  
'Up' and 'Down', 'Menu' and 'Enter' buttons, one is able  
to change and set the values on the 4-line display. The  
display is illuminated and easy to read.  
Transmission in the HMS protocol  
• Frequency-agile in range 5-42 MHz  
The hand-held unit presents the following  
functions:  
Type  
TVM 850/H  
26210077  
75-90.5  
• All appropriately equipped devices or modules can be  
adjusted and operated  
• All settings are displayed  
• The last settings are saved (copy function)  
• The hand-held unit is power-supplied by the respective  
module  
• Distances:  
- Data transfer between HTE 10 and the device or  
module over max. 14 m  
- Standard connection cable: 2 m (included in delivery  
scope)  
Order no.  
Input frequency range  
MHz  
Input level range  
dBµV  
MHz  
dBµV  
W
50-95  
5-42  
105  
1
Output frequency range  
Max. output level  
Power consumption  
Transmission protocol  
HMS  
VGO 939, VGF 939, VGO 939-1G, VGF 939-1G, VOS 952/953, VOS 952-1G,  
VOS 953-1G, ORA 9022, ORA 9022-1G, ORA 920/921, VGP 9033,  
VGP 9033-1G, VGP 9041, VGF 9030/9040  
Suitable for  
- Can be extended to 14 m (TDK 10)  
• 4-line display, illuminated  
• Language: English  
• Splash-proof/shock-proof  
• Ambient conditions:  
TVM 1000 - Monitoring transponder DOCSIS/  
EuroDOCSIS, frequency-agile  
- Ambient temperature: -20 to +50 °C  
- Suitable for outdoor application  
- Protection category: IP 54  
• Control signal: Serial, RS 232  
• Connection: Sub D, 9-pin  
• Accessories (not included in delivery scope):  
TDK 10 (Order no. 26210054): Connection cable 14 m  
TDK 12 (Order no. 26210076): PC connection cable for  
HTE 10 (for software updates)  
• Monitoring transponder for compact/house connection amplifiers and optical com-  
pact receivers (see table)  
• Monitors various parameters such as voltage, current drain and internal temperature  
• Controls the Ingress Control switch in correspondingly equipped devices  
Transmission in DOCSIS or EuroDOCSIS protocol  
• Frequency-agile in range 5-65 MHz and 90-862 MHz  
Type  
TVM 1000  
Order no.  
26210086  
Input frequency range  
Input level range  
MHz  
dBµV  
MHz  
dBµV  
W
90-862  
48-78  
Output frequency range  
Max. output level  
Power consumption  
Transmission protocol  
5-65  
113-118  
3.5  
DOCSIS/EuroDOCSIS 2.0  
VGO 939, VGO 939-1G, VGF 939, VGF 939-1G, VOS 952/953, VOS 952-1G,  
VOS 953-1G, ORA 9022, ORA 9022-1G, ORA 920/921, VGP 9033 as of version A03  
(Nov. 2008), VGP 9033-1G, VGP 9041 as of version A02 (Nov. 2008), VGF 9030/9040  
Suitable for  
1ꢀ  
1ꢁ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Accessories  
Accessories  
EAC 90-1G, 93-1G, 94-1G – Tap-off cards  
EBC 00-1G and EBC 01E-1G – Null cards  
(output, input)  
ERZ 940 – De-emphasis equaliser  
ERS 800 – System equaliser  
• Plug-in modules to extend the corresponding devices  
to two outputs  
• When inserted in the amplifier's input section these  
modules can be used to configure a loop-through input  
• Cable-analogue 7 dB  
• System equaliser for use in special applications  
• Characteristics:  
- Cable-equivalent pre-emphasis in the range 47-700 MHz:  
3 dB (at 47-862 MHz: 4 dB)  
Plug-in modules for operation of the VGP 90xx  
distribution network amplifiers with one input or output  
EBC 01E-1G: For operation on the input insert position  
EBC 00-1G: For operation on the output insert position  
- Cable-equivalent pre-emphasis in the range 700-862 MHz:  
3 dB (equivalent to additional emphasis in the range  
700-862 MHz by 2 dB)  
Type  
ERZ 940  
24510059  
47-862  
75  
Order no.  
Principal frequency response curve ERS 800  
MHz  
Transmission range  
Nominal impedance  
De-emphasis  
Basic loss (at 47 MHz)  
Return loss  
MHz  
0
100  
200  
300  
400  
500  
600  
700  
800  
47  
862  
0
1
2
3
4
5
6
7
dB  
dB  
dB  
7
1
dB  
0.3  
EBC 90-1G – Splitter, 2-way  
20-3  
Type  
EBC 01E-1G  
EBC 00-1G  
Order no.  
24510121  
5-1000  
24510119  
5-1000  
Frequency range  
MHz  
dB  
ERZ 630 – Equaliser  
Through loss ¹)  
< 0.5  
< 0.5  
Type  
Order no.  
ERS 800  
• Equaliser 47-630 MHz  
• Switchable in 2-dB steps from  
2-18 dB (cable equivalent)  
1) The through loss is the signal loss between the unit's output and output 1  
when the insert is inserted in the output section insertion point or between  
the unit‘s input and the tap output when the insert is inserted in the unit's  
input section (input configuration section)  
24510109  
47-862  
75  
Transmission range  
Nominal impedance  
MHz  
EAC  
90-1G  
EAC  
93-1G  
EAC  
94-1G  
EBC  
90-1G  
Type  
Cable-equivalent pre-emphasis,  
47-700/(equivalent to 47-862) MHz:  
dB  
dB  
3/(4)  
3
Order no.  
24510116 24510115 24510114 24510113  
Cable-equivalent pre-emphasis in  
the range 700-862 MHz  
Frequency range  
MHz 5-1000  
5-1000  
< 2.1  
5-1000  
< 0.5  
5-1000  
< 3.6  
ERC 22 - C-line pre-emphasis equaliser  
Basic loss (at 862 MHz)  
Return loss  
dB  
dB  
0.5  
Through loss ¹)  
5-610 MHz  
dB  
dB  
< 1.3  
< 1.3  
< 1.5  
Type  
47-630  
75  
• Generates pre-emphasis based on the C-line specifica-  
tions of Kabel Deutschland  
• For use in the amplifiers VGP 9041/VGF 9040  
• Application in the universal input insert position  
("Forward 1")  
> 15  
Through loss ¹)  
610-862 MHz  
Order no.  
< 2.3  
< 2.6  
< 0.6  
< 0.9  
< 3.8  
< 3.9  
Transmission range  
Nominal impedance  
Basic loss (at 47/630)  
MHz  
Through loss ¹)  
862-1000 MHz  
Like  
through  
loss  
dB  
0.5/1.5  
Tap loss  
dB  
10  
6
20  
Equalisation, adjustable in  
2-dB steps  
dB  
2-18  
Decoupling 5-65 MHz  
dB  
dB  
> 28  
> 26  
> 23  
> 23  
> 38  
> 33  
> 28  
> 22  
Decoupling  
as of 65-610 MHz  
Decoupling  
as of 610-862 MHz  
> 24  
> 22  
> 23  
> 20  
> 30  
> 28  
> 20  
> 18  
Decoupling  
as of 862-1000 MHz  
Type  
ERC 22  
24510085  
50-862  
75  
Order no.  
1) The through loss is the signal loss between the unit's output and output 1  
when the insert is inserted in the output section insertion point or between  
the unit's input and the tap output when the insert is inserted in the unit's  
input configuration section  
Transmission range  
Nominal impedance  
Pre-emphasis  
Basic loss (at 862 MHz)  
Return loss  
MHz  
For C-lines  
1
dB  
dB  
23 -1/oct.  
1ꢂ  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Innovation Technology Headphones ITGSH 150 User Manual
Interquartz Telephone 98380 User Manual
Jasco Headphones 99002 User Manual
Kenwood Car Amplifier TL 922A User Manual
KitchenAid Blender 3 Speed Classic Blender User Manual
Kodak Camcorder 1455013 User Manual
Kodak Film Camera 2393 User Manual
Kolcraft Baby Accessories B26 R2 User Manual
Kompernass Electric Cookie Press KH1190 User Manual
Konica Minolta Camera Accessories T 10A T 10MA T 10WSA T 10WLA User Manual