DESCRIPTION
The compact amplifiers with
electronic tuning elements –
VGP 9033-1G/9041 and VGF 9030/9040
VGP 9033-1G/9041 – VGF 9030/9040
• Modern, monitorable compact amplifiers for inter-
active HFC networks
V
GP 9033-1G/9041-VGF 9030/9040
• Innovative operational concept: Using electronic
tuning elements, set using HTE 10 hand-held unit
(fewer plug-in cards and attenuation pads
required, repeatable device settings)
• Integrated frequency-agile 2-pilot control in
VGP 9033-1G/9041enables quick commissioning:
- Automatic levelling in the forward path, thus no
need for time-consuming manual levelling
- Automatic presetting of the return path is
possible
• Remote configuration of all setting parameters via
monitoring system (can be activated/deactivated)
• High gain (up to 40 dB), variable in interstage
position
With the VGP 9033-1G/9041 and VGF 9030/9040
Kathrein offers a latest-generation compact amplifier
series. A wide range of settings, electronic opera-
tion and excellent technical data – at an unbeatable
price/performance ratio.
Product description
Page 3
Details, Block diagram, Accessories
Technical Data
Page 4-5
Page 6
VGO 939-1G/VGF 939-1G
"Plug-and-Play" redefined
Product description
Page 7
Electronic setting of all important parameters, automatic
levelling (only for VGP 9033-1G/9041) as well as remote
configuration via HMS or DOCSIS monitoring ensure
the shortest start-up and maintenance times. The copy
function enables one to copy all settings and transfer
them to another device at the press of a button.
The absence of plug-in cards for gain and slope
not only accelerates start-up, but also simplifies
logistics and saves warehousing costs.
Details, Block diagram, Accessories
Technical data
Page 8-9
Page 10
• Latest GaAs-MMIC technology
• Very high output levels at lowest intermodulation
products, even for interstage operation
• Loop-through input (only for VGP 9033-1G/9041)
and output splitter can be configured
• De-emphasis (inverse-equalisation) insert position
• Remote feeding: 7 A per input/output,
local feeding: 10 A
VOS 952-1G/953-1G
Another advantage during modifications:
new values are taken over without any interruptions.
Multimedia services remain undisturbed.
Product description
Page 11
Details, Block diagram, Accessories
Technical data
Page 12-13
Page 14-15
• Insert position for monitoring transponder
(HMS/DOCSIS)
• Test sockets on input/output and in return path
amplifier
• Integrated return path amplifier, settable gain
• Ingress Control Switch
• Aluminium die-cast housing with
PG 11 connections
Start-up without a measuring instrument
– it doesn't get any easier than this
Accessories
Due to automatic levelling, the compact amplifiers
VGP 9033/9041 can be put into operation
with just a few steps:
TVM 850/H, TVM 1000
HTE 10
Page 16
Page 17
- Simply enter the desired output level for the
lower and upper pilot frequency and start
levelling
Splitters, Taps, Equalisers
Connectors
Page 18-19
Page 20
- After a few seconds, the device automatically
sets the desired values, whereby optimal technical
data are continuously reached.
Manual vernier adjustment is still possible at any time.
- Subsequently, automatic presetting can also
be effected in the return path.
- For the next devices, levelling runs even more
quickly. The copy function enables desired
settings to be automatically incorporated.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
VGP 9033-1G/9041
VGF 9030/9040
DETAILS, ACCESSORIES, BLOCK DIAGRAM, DELIVERY STATUS
Insert position for monitoring
transponder
Insert position "Forward 2"
(not included in delivery scope)
Connection socket for
hand-held unit HTE 10
Insert position "Forward 1"
e.g. for additional C-line
pre-emphasis
F-type test socket
internal (-20 dB)
Image: VGP 9033-1G/9041
Delivery status
• EAC 93-1G (Order no. 24510115): Tap (3/6 dB)
• EAC 90-1G (Order no. 24510116): Tap (1.5/10 dB)
• EAC 94-1G (Order no. 24510114): Tap (0.8/20 dB)
• Note: The input and output plug-in positions
must each be equipped with a EBC/EAC xx
for operation. The other plug-in positions are
already equipped with null cards
• Input and output cable fittings not included
in the delivery scope (see page 20)
• Please note that the VGF 9030/9040 does
not include remote-feed fuses in its delivery
scope (see page 20)
• ERC 22
(Order no. 24510085):
C-line pre-emphasis equaliser for
VGP 9041/VGF 9040
• ERZ 630
• ERS 800
• ERD 810
• ERD 813
• ERD 814
(Order no. 24510108):
Equaliser 630 MHz
(Order no. 24510109):
System equaliser 862 MHz
(Order no. 24510110): De-emphasis
equaliser switchable, 862 MHz
(Order no. 24510117):
F-type
test socket
internal
Image: VGP 9033-1G/9041
(-20 dB)
De-emphasis equaliser
(Order no. 24510120): Attenuation pad
F-type broadband input
for the return path with
protective cap (-10 dB)
• TVM 850/H (Order no. 26210077):
Monitoring transponder HMS
(5-24 MHz), frequency-agile
• TVM 1000 (Order no. 26210086):
Monitoring transponder DOCSIS
Input insert position
Accessories
• EBC 01E-1G (Order no. 24510121): Null card input
• EBC 00-1G (Order no. 24510119): Null card output,
for operation with one output
Output insert position
• FUN 15
(Order no. 25010017):
FUN remote-feed fuse 15A/125 VDC
(Order no. 25010005): Hand-held unit
• EBC 90-1G (Order no. 24510113): Splitter
(2 outputs symmetrical)
• HTE 10
4
5
Download from Www.Somanuals.com. All Manuals Search And Download.
For details see pages 16-20
VGO 939-1G/
VGF 939-1G
VGP 9033-1G/9041
VGF 9030/9040
Technical Data
DESCRIPTION
DATA
Type
VGF 9030
VGF 9040
VGP 9033-1G
VGP 9041
VGO 939-1G/VGF 939-1G
The compact amplifier with
slide switches –
VGO 939-1G/VGF 939-1G
Order no.
24410108
24410109
24410103
24410054
• Latest GaAs-MMIC technology
• Innovative operational concept:
- Settings via slide switches
- Device settings can be reproduced exactly
- Fewer plug-in cards and variable attenuators
needed
• Integrated diplexers allow optimised data
• Very high output level at lowest intermodulation
products (also for interstage attenuation)
• Pluggable loop-through output
• One or two output(s) configurable
• Built-in active return path with various setting
possibilities
• Return path can also be operated passively
• 15 MHz high pass can be activated in the
return path
• Ingress Control Switch (ICS)
• Monitorable with HMS or DOCSIS transponder
(option)
• Insert position for additional functions in the
forward path (e.g. de-emphasis)
• Bi-directional test socket on the amplifier input
• Directional coupler test socket on amplifier output
and in return path
• Test signals can be coupled in for the return path
• LED as function indicator
• Highly efficient switched-mode power supply unit
• Advanced remote power concept in the
VGF 939-1G:
- Newly developed remote feed coils
- Remote feed current: Max. 7 A per connec-
tion, local insertion max. 10 A totally
- Remote feeding possibilities: By choice via
all RF connections or local connector
(power passing)
FORWARD PATH
Frequency range
MHz
dB
85-862
33
85-862
40
85-1000
33
85-862
40
In addition to the devices with electronic setting,
Kathrein offers yet another highly innovative
compact amplifier platform. This particularly
economical series requires no equaliser cards
or attenuation pads. All adjustments can be easily
carried out using slide switches.
Gain (at 1000 MHz)
Return loss
dB
19-1.5 dB/oct.
Frequency response (85-1000 MHz at 25 °C)
Max. output level according to CENELEC 1) - CTB > 60 dB
Max. output level to CENELEC 1) - CSO > 60 dB
dB
0.5
114
116
dBµV
dBµV
dB
5)
Attenuation range, electronically settable in 0.5 dB steps
0-16
0-15
0-15
0-5
0-16
0-20
-
5)
Slope range, electronically settable in 0.5 dB steps
dB
0-20
Simple, yet effective
Interstage attenuation, settable in 1 dB steps
Interstage pre-emphasis, electronically settable in 2.5 dB steps
Noise figure at minimum pre-emphasis
Adjustment range, sloped at 85 MHz
-
dB
dB
2-9
2,5-10
6.5
2-9
6
The required attenuation and slope values are
set with a combination of several slide switches.
The advantages are obvious. Besides saving
plug-in cards, this allows exact reproduction of
setting values without requiring a measuring
instrument.
6
dB
-
2
3
Adjustment range, parallel
dB
-
Frequency range lower pilot Pu ²)
MHz
MHz
dBµV
dB
85-230
570-870
85-230
> 67
82.5-230
570-870 5)
)
Frequency range upper pilot Po ²
Pilot level (PAL/CW/QAM)
Hum modulation ratio at 7 A
RETURN PATH
83-112
5-65
Replacement of the device, for example, is thus
much easier.
70
70
30
Frequency range
MHz
dB
When slide switches are shifted, a virtually uninter-
rupted signal flow is guaranteed – multimedia
services remain undisturbed.
Gain
30
28
Frequency response at 25 °C
dB
0.5
0.3
0.5
6)
Input level density (CINR = 50 dB), at 28 dB gain
dBµV/Hz
dB
-9
21
6)
Dynamic range: CINR > 50 dB, 5-65 MHz, at 28 dB gain
7)
Dynamic range: CINR > 50 dB, 5-65 MHz, at 18 dB gain
dB
26
Maximum reliability
Noise figure
dB
6
Attenuation, switchable in 1 dB steps
Slope, switchable in 7 steps
dB
0-30
1-8
The implemented slide switches fulfil the highest
demands regarding reliability and endurance.
Dual gold-plated contact reeds, increased
contact pressure and a separate catch spring
ensure ultimate reliability of the switches, which
have been proven and tested 100,000 times.
dB
ICS switch (attenuation switchable over EMS or
HTE 10 hand-held unit)
dB
dB
0/6/> 45
60
Hum modulation ratio at 7 A/> 15 MHz
GENERAL
Voltage supply
V AC
W
30-72
Power consumption
21
23
• Surge absorber on all RF connections and in
switched-mode power supply unit
• Power management: Unused amplifier stage
switch-off for reduced power consumption
• Die-cast housing with PG 11 connectors
• Easy connection of large cable fittings due to
extended thread distance
Max. remote feed current per connection
Max. remote feed current in local feeding (power passing)
RF connections
A
7
A
10
PG 11
Housing protection category
Ambient temperature range
Screening factor
IP 54
IP 67
°C
-20 to +55
Conforms to CENELEC EN 50083-2
2 kV (1.2/50 µs)
Overvoltage protection acc. to IEC 60-2
Dimensions (W x H x D)
• Outdoor operation possible, housing protection
class: IP 54
mm
240 × 95 × 240 3)
NETWORK MANAGEMENT (optional)
• Test sockets: F-type connectors (internal)
Operational voltage; current; temperature; electronic tuning elements; pilot setting and
alarm; automatic levelling of forward path; automatic presetting of return path; return
path gain; ICS switch; remote inventory data
Monitorable/settable parameters
1)
2)
6)
3)
7)
4)
5)
For VGP 9033-1G in 1 dB steps
9 dB slope
Set using HTE 10 hand-held unit
For VGF 90xx at 30 dB gain
Width incl. hinges: 267 mm
For VGF 90xx at 20 dB gain
As of device version Bxx from 570-870 MHz
ꢀ
ꢁ
Download from Www.Somanuals.com. All Manuals Search And Download.
VGO 939-1G/
VGF 939-1G
DETAILS, ACCESSORIES, BLOCK DIAGRAM, DELIVERY STATUS
Input insert position e.g. for
de-emphasis equaliser
Insert position for monitoring
transponder (not supplied)
Option
Interstage
Forward path: Adjustment
of attenuation and
equalisation using slide
switches
De-emphasis
4 / 0 / 8 dB
1 / 0 / 2 dB 3 / 0 / 6 dB
0 / 10 dB 2 / 0 / 4 dB 6 / 0 / 12 dB 2 / 0 / 4 dB 6 / 0 / 12 dB
LED (Power supply
function)n)
dB
dB
dB
dB
Pre-emphasis
Attenuation
Attenuation
-20 dB
Attenuation
Pre-emphasis
Attenuation
or
pre-emphasis
Monitoring transponder
Current
Temperature
85 - 1006 MHz
85 - 1006 MHz
5 - 65 MHz
Ub
ICS
5 - 65 MHz
Option
30 dB
21 dB
Switched-off
4 / 0 / 8 dB
3 / 0 / 6 dB
2 / 0 / 4 dB 6 / 0 / 12 dB
-30 dB
(Return path:
= 70 dBµV)
passive
dB
dB
Attenuation
dB
P
nominal
active
0 / -8 dB /
"switched-off"
Attenuation
Internal
5 MHz
Test 2
v = 14 dB
Pre-emphasis
5-65 MHz
-20 dB
Internal
15 MHz
Ingress
detection
Test 3
-10 dB
Internal
S10
(Pnom=ina6l0 dBµV)
Test 1
-20 dB
bi-directional
Return path
measurement
or feed-in
Option
max. 7 A
Option
power passing: 10 A
32-72 VAC
Loop through
splitter field
SNT
Output
splitter field
C
15 A
T3,15AL
A
D
B
E
Output 1
PG11
Input
PG11
Loop through
PG11
Output 2
PG11
= slide switches
A/B/E/D = 15-A fuse
ERZ 940
(Order no. 24510059):
De-emphasis equaliser
(cable-analogue) 862 MHz,
7 dB fixed
(Order no. 24510110):
De-emphasis equaliser
(Order no. 24510117):
De-emphasis equaliser
•
Delivery status
• For operation with one input or output, no
plug-in cards required
• All insert positions are fitted with 0-dB
bridging plugs ex works
• Input and output cable fittings not included in
the delivery scope (see page 20)
Output splitter field
ERD 810
ERD 813
•
•
Direct supply to
device up to
10 A
F-type test
ERD 814
ERZ 630
(Order no. 24510120):
De-emphasis equaliser/attenuator
(Order no. 24510108):
Equaliser 47-630 MHz, switchable
in 2-dB steps from 2-18 dB
(Order no. 24510109):
•
•
socket for
the return
path
F-type test socket on
output for return path
measurement or feed-in
(-20 dB)
Accessories
Splitter field
loop-through input
(-10 dB)
• EBC 90-1G
(Order no. 24510113)
Splitter
ERS 800
•
•
System equaliser 862 MHz
(2 outputs symmetrical)
(Order no. 24510115):
Tap (3/6 dB)
(Order no. 24510116):
Tap (1.5/10 dB)
F-type test
socket
bidirectional on
input (-20 dB)
TVM 850/H (Order no. 26210077):
Monitoring transponder HMS
• EAC 93-1G
• EAC 90-1G
• EAC 94-1G
Return path
switchable
passive/active
(5-42 MHz), frequency-agile
(Order no. 26210086):
Monitoring transponder DOCSIS
Integrated return path
amplifier, adjustable
with slide switches
TVM 1000
•
Order no. 24510114):
Tap (0.8/20 dB)
ꢂ
9
Download from Www.Somanuals.com. All Manuals Search And Download.
VGO 939-1G/
VGF 939-1G
DESCRIPTION
DATA
VOS 952-1G/953-1G
Technical Data
Type
VGO 939-1G
VGF 939-1G
Notes
House connection amplifiers
VOS 952-1G/953-1G
Order no.
24410101
Locally fed
24410100
Remotely fed
• Latest GaAs-MMIC technology
• Innovative operational concept:
- Settings via slide switches
- Device settings can be reproduced exactly
- Fewer plug-in cards and variable attenuators
needed
The compact, price-optimised house connection
amplifiers 952-1G and VOS 953-1G were designed
for application in modern HFC networks. Great value
was set upon a high dynamic range for Interstage
operation as well as upon a cost-efficient operation
concept with slide switches.
FORWARD PATH
Frequency range
MHz
dB
85-1000
Gain
40
32-40
Gain setting range, interstage ³)
Amplitude response
dB
dB
0.5
85-1000 MHz, at 25 °C
at 25 °C
Amplitude response (additional, 862-1000 MHz)
dB
-0.5
• Very high output level at lowest intermodula-
tion products
• Built-in active return path with various setting
possibilities
• 15 MHz high pass can be activated in the
return path
• Ingress Control Switch (ICS)
• Monitorable with HMS or DOCSIS (option)
• Insert position for additional functions in the
forward path (e.g. de-emphasis)
• Bi-directional test socket on amplifier input
with inductive coupling
• Directional coupler test socket on amplifier
output and in return path
• Test signals can be coupled in for the return
path
• Highly efficient switched-mode power supply
unit
• VOS 952-1G - locally fed, F-type connectors
• VOS 953-1G - remotely fed (auto-supply),
F-type sockets
• Surge absorbers on all RF connections and in
switched-mode power supply unit
• Die-cast housing
³)
Attenuation setting range, on input
dB
0-26
³)
Pre-emphasis setting range, at input or interstage
dB
0-26 or 0/4/8
18-1.5/oct.
4
Monitoring via DOCSIS transponder
Return loss, as of 40 MHz
Noise figure
dB
dB
at 40 dB gain
If fitted with the optional monitoring transponder
TVM 1000/H, the amplifiers VOS 952-1G/953-1G
can be monitored via DOCSIS protocol. Monitoring
with HMS Both amplifiers can be flexibly integrated
into monitoring systems which operate with the
widespread HMS protocol.
¹)
Max. operational level: CENELEC raster
dBµV
dB
116/118
CTB: 60 dB/CSO: 60 dB (pre-emphasis 4 dB)
AT 7 A, 5-65/85-1000 MHz
Hum modulation ratio
-
60/70
RETURN PATH
Frequency range
MHz
dB
5-65
Gain (input stage bridged), active operation
Gain, passive operation
30 (21)
dB
-2
Amplitude response
dB
0.5
Attenuation setting range, at input or interstage ³)
Pre-emphasis setting range, interstage
Ingress Control Switch (ICS)
Max. output level at 30 and 21 dB gain
Max. output level
dB
0/4/8 or 0-16
Bridgeable diplex filter
dB
0/3/6
8/> 40
107/116
120
dB
attenuated/switched-off
Bridging plugs enable variation of the frequency
range between 47-1000 MHz and 85-1000 MHz
making it possible to carry out transmission in
BAND I in the forward path (without return path).
dBµV
dBµV
dBµV/Hz
dB
60 dB IMod2/IMod3 (EN 60728-3/50083-5)
According to KDG 1 TS 140 (full system load)
CINR at 50 dB (EN 60728-3/item 4.7)
Input level density
-8
Dynamic range at 30 dB gain (5-65 MHz) ²)
Dynamic range at 21 dB gain (5-65 MHz) ²)
Noise figure
18
dB
25
dB
6
Flexible return path
NETWORK MANAGEMENT
Internal voltage supply, internal current drain,
internal temperature, ICS switch
Monitorable parameters
In the latest generation, the
return path can be
operated either actively or passively.
Test sockets
Test socket 1 (on amplifier input), bi-directional
dB
dB
dB
20
20
10
Possibility to feed in return path signals
(5-65 MHz); if button is kept pressed, the
incoming return path signal can be measured
Test socket 2 (on amplifier output), directional coupler
• Test sockets: F-type sockets
Test socket 3 (in return path amplifier), directional coupler
SWITCHED-MODE POWER SUPPLY
Nominal input voltage
Attenuation relative to return path input
V AC
Hz
A
230
32-72
Mains frequency range
50-60
17.5
Max. remote feed current
-
-
7
per input or output
Max. remote feed current, local insertion
Power consumption (without monitoring)
GENERAL
A
10
W
Return path amplifier active
Classification according to KDG 1 TS 140
Ambient temperature range
RF connections
D(4.4)
-20 to +55
PG 11
°C
data-conform operation
Test sockets
F-type connector
IP 54
Housing protection class (to EN 60529)
Dimensions (W x H x D)
mm
238 × 86 × 189
1(10)/2.2
3)
Settable in 2-dB steps using slide switches
Packing unit/weight
pc./kg
11
1)
2)
When the 15 MHz high pass is connected, the dynamic range increases by 3 dB
CENELEC: 41 channels
Download from Www.Somanuals.com. All Manuals Search And Download.
DETAILS, ACCESSORIES, BLOCK DIAGRAM, DELIVERY STATUS
VOS 952-1G/953-1G
Insert position for
monitoring transponder
(not included in delivery scope)
Input insert position e.g.
for de-emphasis equaliser
Forward path:
Adjustment of
attenuation and
equalisation using
slide switches
LED (Power
supply function))
Delivery status
Accessories
• ERZ 940
(Order no. 24510059):
De-emphasis equaliser
• The insert position is fitted with a
0-dB bridging plug ex works
(cable-analogue) 862 MHz, 7 dB fixed
(Order no. 24510108): Equaliser
47-630 MHz, 2-18 dB in 2-dB steps
(Order no. 24510109):
System equaliser 862 MHz
(Order no. 24510110):
F-type test socket
on output
for return path
measurement or
feed-in (-20 dB)
• ERZ 630
• ERS 800
• ERD 810
Return path
switchable
passive/active
F-type test socket
bidirectional on input (-20 dB)
De-emphasis equaliser,
switchable 3 dB
• TVM 850/H Order no. 26210077):
Monitoring transponder HMS
F-type test socket for the return path
(-10 dB)
Integrated return path
amplifier, adjustable
with slide switches
protocol (frequency-agile)
• TVM 1000
(Order no. 26210086): Monitoring
transponder DOCSIS protocol
12
13
Download from Www.Somanuals.com. All Manuals Search And Download.
VOS 952-1G/953-1G
DATA
Technical Data
Type
VOS 952-1G
24410098
VOS 953-1G
24410099
Notes
Type
VOS 952-1G
24410098
VOS 953-1G
24410099
Notes
Order no.
Order no.
Locally fed
Remotely fed
Locally fed
Remotely fed
SWITCHED-MODE POWER SUPPLY
Nominal input voltage
FORWARD PATH
Frequency range
V AC
Hz
230
38-65
50-60
MHz
dB
47/85-1000
40-32
47/85-1000
40-32
¹)
Mains frequency range
50-60
Gain
Interstage gain setting
85-1000 MHz, at 25 °C
Return path amplifier active/
without monitoring
Amplitude response
dB
0.5
0.5
Power consumption
W
11
12
Amplitude response (additional,
862-1000 MHz)
dB
dB
-0.5
0-16
-0.5
0-16
at 25 °C
GENERAL
Attenuation setting range
On amplifier input
Ambient temperature range
RF connections
Test sockets
°C
-20 to +55
F-type socket
F-type socket
-20 to +55
F-type socket
F-type socket
On amplifier input
and interstage
Pre-emphasis setting range
dB
0-16 and 0/6
4/5/5
0-16 and 0/6
4/5/5
Noise figure
dB
At 40/36/32 dB gain
IP 54: Outdoor use in weather-
proof cabinet
Housing protection class (to EN 60529)
IP 54
IP 54
Max. operational level: CENELEC channel
CTB: 60 dB/CSO: 60 dB (pre-
emphasis 6 dB and gain 40 dB)
dBµV
dB
112/116
-
112/116
>60/70
²)
plan
Dimensions (W x H x D)
Packing unit/weight
mm
225 × 55 × 155
1(10)/1.8
225 × 55 × 155
1(10)/1.8
Hum modulation ratio
RETURN PATH
pc./kg
Frequency range
MHz
dB
5-65
30/21
5-65
30/21
1) Adjustable with 2 slide switches in 1 dB steps
2) CENELEC: 42 channels
3) When the 15 MHz high pass is connected, the dynamic range increases by 3 dB
Gain, switchable
Frequency response
Attenuation setting range
Pre-emphasis setting range
Ingress Control Switch (ICS)
dB
0.5
0.5
dB
0-16 / 0/4/8
0/3/6
0-16 / 0/4/8
0/3/6
On input/interstage
Interstage
dB
dB
8/> 40
8/> 40
attenuated/switched-off
60 dB IM2/IM3
(EN 60728-3/50083-5)
Max. output level at 30 and 21 dB gain
Maximum output level
dBµV
dBµV
107/116
120
107/116
120
According to KDG 1 TS 140
(medium system load)
CINR at 50 dB (EN 60728-3/
item 4.7)
Input level density
dBµV/Hz
-10
-10
Dynamic range at 30 dB gain (5-65 MHz) ³)
Dynamic range at 21 dB gain (5-65 MHz) ³)
Noise figure
dB
dB
dB
17
25
5
17
25
5
NETWORK MANAGEMENT
Internal supply voltage,
internal current drain,
Internal supply voltage,
internal current drain,
Monitorable parameters
temperature, ICS switch temperature, ICS switch
TEST SOCKETS
5-862 MHz bi-directional,
internal
Test socket 1 (on amplifier input)
dB
dB
dB
20
20
10
20
20
10
5-862 MHz with directional
coupler, external - return path
signals can be fed in (5-65
MHz); if push-button is kept
pressed, the incoming return
path signal can be measured
Test socket 2 (on amplifier output)
Test socket 3 (in return path)
5-65 MHz with directional
coupler, external
14
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Accessories
HTE 10 - Hand-held unit
Monitoring transponder HMS protocol,
frequency-agile
• Monitoring transponder for compact amplifiers, house connec-
tion amplifiers and optical compact receivers (see table)
• Monitors various parameters such as voltage, current drain and
internal temperature
• Controls the Ingress Control switch in correspondingly equip-
ped devices
With the HTE 10 hand-held unit one is able to adjust
correspondingly equipped devices on site. Using the
'Up' and 'Down', 'Menu' and 'Enter' buttons, one is able
to change and set the values on the 4-line display. The
display is illuminated and easy to read.
• Transmission in the HMS protocol
• Frequency-agile in range 5-42 MHz
The hand-held unit presents the following
functions:
Type
TVM 850/H
26210077
75-90.5
• All appropriately equipped devices or modules can be
adjusted and operated
• All settings are displayed
• The last settings are saved (copy function)
• The hand-held unit is power-supplied by the respective
module
• Distances:
- Data transfer between HTE 10 and the device or
module over max. 14 m
- Standard connection cable: 2 m (included in delivery
scope)
Order no.
Input frequency range
MHz
Input level range
dBµV
MHz
dBµV
W
50-95
5-42
105
1
Output frequency range
Max. output level
Power consumption
Transmission protocol
HMS
VGO 939, VGF 939, VGO 939-1G, VGF 939-1G, VOS 952/953, VOS 952-1G,
VOS 953-1G, ORA 9022, ORA 9022-1G, ORA 920/921, VGP 9033,
VGP 9033-1G, VGP 9041, VGF 9030/9040
Suitable for
- Can be extended to 14 m (TDK 10)
• 4-line display, illuminated
• Language: English
• Splash-proof/shock-proof
• Ambient conditions:
TVM 1000 - Monitoring transponder DOCSIS/
EuroDOCSIS, frequency-agile
- Ambient temperature: -20 to +50 °C
- Suitable for outdoor application
- Protection category: IP 54
• Control signal: Serial, RS 232
• Connection: Sub D, 9-pin
• Accessories (not included in delivery scope):
TDK 10 (Order no. 26210054): Connection cable 14 m
TDK 12 (Order no. 26210076): PC connection cable for
HTE 10 (for software updates)
• Monitoring transponder for compact/house connection amplifiers and optical com-
pact receivers (see table)
• Monitors various parameters such as voltage, current drain and internal temperature
• Controls the Ingress Control switch in correspondingly equipped devices
• Transmission in DOCSIS or EuroDOCSIS protocol
• Frequency-agile in range 5-65 MHz and 90-862 MHz
Type
TVM 1000
Order no.
26210086
Input frequency range
Input level range
MHz
dBµV
MHz
dBµV
W
90-862
48-78
Output frequency range
Max. output level
Power consumption
Transmission protocol
5-65
113-118
3.5
DOCSIS/EuroDOCSIS 2.0
VGO 939, VGO 939-1G, VGF 939, VGF 939-1G, VOS 952/953, VOS 952-1G,
VOS 953-1G, ORA 9022, ORA 9022-1G, ORA 920/921, VGP 9033 as of version A03
(Nov. 2008), VGP 9033-1G, VGP 9041 as of version A02 (Nov. 2008), VGF 9030/9040
Suitable for
1ꢀ
1ꢁ
Download from Www.Somanuals.com. All Manuals Search And Download.
Accessories
Accessories
EAC 90-1G, 93-1G, 94-1G – Tap-off cards
EBC 00-1G and EBC 01E-1G – Null cards
(output, input)
ERZ 940 – De-emphasis equaliser
ERS 800 – System equaliser
• Plug-in modules to extend the corresponding devices
to two outputs
• When inserted in the amplifier's input section these
modules can be used to configure a loop-through input
• Cable-analogue 7 dB
• System equaliser for use in special applications
• Characteristics:
- Cable-equivalent pre-emphasis in the range 47-700 MHz:
3 dB (at 47-862 MHz: 4 dB)
• Plug-in modules for operation of the VGP 90xx
distribution network amplifiers with one input or output
• EBC 01E-1G: For operation on the input insert position
• EBC 00-1G: For operation on the output insert position
- Cable-equivalent pre-emphasis in the range 700-862 MHz:
3 dB (equivalent to additional emphasis in the range
700-862 MHz by 2 dB)
Type
ERZ 940
24510059
47-862
75
Order no.
Principal frequency response curve ERS 800
MHz
Transmission range
Nominal impedance
De-emphasis
Basic loss (at 47 MHz)
Return loss
MHz
Ω
0
100
200
300
400
500
600
700
800
47
862
0
1
2
3
4
5
6
7
dB
dB
dB
7
1
dB
0.3
EBC 90-1G – Splitter, 2-way
20-3
Type
EBC 01E-1G
EBC 00-1G
Order no.
24510121
5-1000
24510119
5-1000
Frequency range
MHz
dB
ERZ 630 – Equaliser
Through loss ¹)
< 0.5
< 0.5
Type
Order no.
ERS 800
• Equaliser 47-630 MHz
• Switchable in 2-dB steps from
2-18 dB (cable equivalent)
1) The through loss is the signal loss between the unit's output and output 1
when the insert is inserted in the output section insertion point or between
the unit‘s input and the tap output when the insert is inserted in the unit's
input section (input configuration section)
24510109
47-862
75
Transmission range
Nominal impedance
MHz
Ω
EAC
90-1G
EAC
93-1G
EAC
94-1G
EBC
90-1G
Type
Cable-equivalent pre-emphasis,
47-700/(equivalent to 47-862) MHz:
dB
dB
3/(4)
3
Order no.
24510116 24510115 24510114 24510113
Cable-equivalent pre-emphasis in
the range 700-862 MHz
Frequency range
MHz 5-1000
5-1000
< 2.1
5-1000
< 0.5
5-1000
< 3.6
ERC 22 - C-line pre-emphasis equaliser
Basic loss (at 862 MHz)
Return loss
dB
dB
0.5
Through loss ¹)
5-610 MHz
dB
dB
< 1.3
< 1.3
< 1.5
Type
47-630
75
• Generates pre-emphasis based on the C-line specifica-
tions of Kabel Deutschland
• For use in the amplifiers VGP 9041/VGF 9040
• Application in the universal input insert position
("Forward 1")
> 15
Through loss ¹)
610-862 MHz
Order no.
< 2.3
< 2.6
< 0.6
< 0.9
< 3.8
< 3.9
Transmission range
Nominal impedance
Basic loss (at 47/630)
MHz
Through loss ¹)
862-1000 MHz
Ω
Like
through
loss
dB
0.5/1.5
Tap loss
dB
10
6
20
Equalisation, adjustable in
2-dB steps
dB
2-18
Decoupling 5-65 MHz
dB
dB
> 28
> 26
> 23
> 23
> 38
> 33
> 28
> 22
Decoupling
as of 65-610 MHz
Decoupling
as of 610-862 MHz
> 24
> 22
> 23
> 20
> 30
> 28
> 20
> 18
Decoupling
as of 862-1000 MHz
Type
ERC 22
24510085
50-862
75
Order no.
1) The through loss is the signal loss between the unit's output and output 1
when the insert is inserted in the output section insertion point or between
the unit's input and the tap output when the insert is inserted in the unit's
input configuration section
Transmission range
Nominal impedance
Pre-emphasis
Basic loss (at 862 MHz)
Return loss
MHz
Ω
For C-lines
1
dB
dB
23 -1/oct.
1ꢂ
19
Download from Www.Somanuals.com. All Manuals Search And Download.
|