| HD 10/25 S VEX   5.961-066 A 2006919 10/03   Download from Www.Somanuals.com. All Manuals Search And Download.   Download from Www.Somanuals.com. All Manuals Search And Download.   HD 10/25 S VEX   4 Download from Www.Somanuals.com. All Manuals Search And Download.   English   Operating Instructions HD 10/25 S VEX   Unit components   For your safety   Please fold out illustration page at the front   1 Hand-held spray gun   2 Lever of hand-held spray gun   3 High-pressure hose   4 Handgun support   Before you use the cleaner for the first time,   read these operating instructions and take   special note of the accompanying booklet   "Safety Instructions for High-Pressure Clean-   ers" No. 5.951-949.   5 Detergent metering valve   6 Cap for detergent reservoir   7 Detergent reservoir   8 Detergent suction-hose with filter   9 Fastening screw for hood   10 Unit switch   Use of the cleaner   Use this unit exclusively for   – cleaning with high-pressure jet and deter-   gent (e.g. cleaning of machines, vehicles,   buildings, tools),   11 Hood   – cleaning with high-pressure jet without de-   tergent (e.g. cleaning facades, terraces,   gardening equipment).   12 Pressure gauge   13 High-pressure outlet   14 Nozzle rest   For stubborn dirt we recommend the dirt   blaster as an optional accessory.   15 Water connection   16 Fine filter   17 Oil level display   Safety features   18 Oil reservoir   19 Indicator light   20 Hose rest   Relief valve with pressure   switch   On reducing the flow rate with the pressure   and flow control, the relief valve opens and   part of the water runs back to the suction side   of the pump.   21 Detergent reservoir vent   22 Accessories box   23 Cable holder   24 Handle   25 Nozzle   If the lever of the hand-held spray gun is re-   leased, the pressure switch switches the   pump off. If the lever is retracted, the pressure   switch switches the pump on again.   26 Marking of the nozzle   27 Spray lance   28 Pressure/flow control   29 Safety catch of hand-held spray gun   The overflow valve and pressure switch have   been set and sealed at the factory.   Adjustments are made only by Customer   Service.   5 Download from Www.Somanuals.com. All Manuals Search And Download.   Operating Instructions HD 10/25 S VEX   English   Preparing the unit for use   Switching on the unit   Unpack the unit   Electrical connection   – When unpacking the unit, check the con-   tents of the packaging. If there has been   any damage in transit inform the dealer.   Caution!   The voltage specified on the model rat-   ing plate must correspond to the voltage sup-   plied.   – Do not dispose of the packaging with the   household rubbish, hand it in at the appro-   priate collection point for recycling.   Caution!   The maximum tolerable mains   impedance at the electrical contact point (see   Technical Data) must not be exceeded.   Check the oil level   Caution!    Read the oil level displayed while unit is at   a standstill. The oil level must be above the   two indicators.   Use an extension cable with a sufficient   cable cross-section (see Technical Specifica-   tions) and unwind it fully from the cable drum.   Activate the oil reservoir vent    Unscrew the fastening screw of the hood   For connected loads see model rating plate/   Technical Specifications.   and remove the hood.   Caution!   It is essential that the unit is connected   to the power supply by means of a plug. An in-   separable connection to the power supply is   prohibited. The plug is used to disconnect   from the mains.    Cut off the tip on the cover to the oil reser-   voir.    Fasten the unit cover.   Mount the accessories    Mount nozzle on the spray lance (see   markings on the top of the setting ring).   Water connection/Suction feed   operation    Fit the spray lance to the hand-held spray   gun with pressure and flow control.   Connection to water main    Lock cable clincher into bore lateral to the   Caution!   handle.   Pay attention to the regulations of the   water supply company; according to DIN   1988, the unit may not be connected direct to   the public drinking water supply. A short-term   connection via a non-return valve   (Order no. 6.412-578) is allowed.    Tighten the high-pressure hose according-   ly.   For connected loads see Technical Specifica-   tions.    Connect a supply hose (not supplied) to the   water outlet on the unit and to the water in-   let (e.g. water tap).    Open water inlet.   6 Download from Www.Somanuals.com. All Manuals Search And Download.   English   Operating Instructions HD 10/25 S VEX   Suctioning water from an open container   Selecting the type of spray   The handgun must be closed.    Screw suction hose with filter   (Order no. 4.440-238) to the water outlet.    Rotate the housing of the nozzle until the   desired symbol corresponds with the mark-   ing.    Vent the unit before using.    To evacuate air from the unit, unscrew the   nozzle and leave the unit running until wa-   ter exits with no air bubbles.    Select pencil jet or fan jet by contactless   changeover:    Switch off the unit and screw the nozzle   back on.   rotate the spray lance, which is pointing   down at an angle of approx. 45°, to the left   or right.   Explanation of the symbols   Operating the unit   High-pressure pencil jet (0°),   for particularly stubborn accumu-   lation of grime.   High-pressure fan jet (25°), for   dirt accumulation over a large   surface.   Danger!   ! Observe the relative safety regulations   when using the unit at filling stations or other   high-risk areas.   Caution!   Low-pressure fan jet (CHEM)   for operation with detergent or for   cleaning at low pressure.   Only clean engines in places which   have appropriate oil separators (protection of   the environment).   Caution!   Only wash animals with the low-   pressure fan jet (see "Selecting the type of   spray").   Operating with high pressure   The unit is equipped with a pressure switch.   The motor only starts up when the lever is re-   tracted.    Set the unit switch to "I". The indicator light   will go green.    Unlock the hand-held spray gun and retract   the lever of the gun.    Adjust operating pressure and flow rate   (+/–) by rotating the pressure/flow control   (infinitely variable).    At the lowest flow rate the waste heat from   the motor will heat the water to approx.   15 °C.   7 Download from Www.Somanuals.com. All Manuals Search And Download.   Operating Instructions HD 10/25 S VEX   English   Operating with detergent   Interrupting the operation   Caution!    Release lever of the handgun, the unit   switches off. Retract lever again and the   unit switches on again.   Unsuitable detergents can harm the   cleaner and the object which is to be cleaned.   Use only detergents which are released by   Kärcher. Proportions of detergent to be used   and accompanying instructions should be not-   ed carefully. Use detergents sparingly out of   consideration for the environment.   Availability time   Within the availability time, the unit starts   when the hand-held spray gun is opened.   The indicator light will go green.   Kärcher cleaning agents guarantee trouble-   free operation. Please seek advice or ask for   our catalogue of information sheets on clean-   ing agents.   If the spray gun remains closed for   30 minutes, the availability time ends.   The indicator light will flash green.    Fill detergent reservoir.   Reset availability time    Switch off the unit switch.    Wait a moment.    Set nozzle to   .  Set the detergent metering valve to the   desired concentration.    Switch the unit back on again.   Concentration of detergent when flow at   maximun:   Customer Service can change the unit to   permanent operation.   Position of metering   valve   1 3 5 7 Switching the unit off    Set unit switch to "0" and pull out power   plug.   0.5 2.5 5.0 7.0   % % % %  Close water inlet.    Retract lever until the unit is without pres-   sure.   Recommended cleaning methods    Spray detergent with low pressure jet spar-   ingly over the dry surface to be cleaned and   let it take effect but not dry out.    Push safety catch of the hand-held spray   gun forward to lock the lever of the gun   from being actuated inadvertently.    Spray off (rinse off) the loosened dirt using   the high-pressure spray.   Danger!   ! Risk of scalding due to hot water. Re-    When you have finished the operation, set   detergent metering valve to "0" and switch   the unit on for about 1 minute and rinse it   clear of detergent.   sidual water contained in the switched off unit   can heat up. When removing the hose from   the water inlet, the heater water can spurt out   and cause scalds. Do not remove the hose   until the unit has cooled down.   Transporting the cleaner    To transport the cleaner over relatively long   stretches, take hold of it by the handle and   pull it along behind you.    Empty the detergent reservoir before trans-   porting it horizontally.   8 Download from Www.Somanuals.com. All Manuals Search And Download.   English   Operating Instructions HD 10/25 S VEX   Storing the cleaner   Before each use    Place the handgun in the support.    Check connecting cable for damage (risk of   getting an electric shock), have a damaged   connecting cable replaced without delay by   authorised Customer Service personnel or   an electrician.    Reel in the high-pressure hose and hang it   over the hose rest.   or    Coil the connecting cable round the cable/   hose rest.    Check high-pressure hose for damage   (danger of explosion), replace a damaged   high-pressure hose without delay.   Frost protection    Check unit (pump) for any leaks.   Three drops per minute are allowable and   can appear on the underside of the unit.   Seek the help of Customer Service if leaks   are more serious.   Caution!   Frost will destroy a unit that is not com-   pletely empty of water! Store the unit where it   will be free of frost.   If storage away from frost is not possible:    Empty the detergent tank (see care and   maintenance/As and when required).   Every week    Check oil level in oil reservoir: if the oil is   milky (water in oil), seek the help of Cus-   tomer Service immediately.    Drain off the water and rinse the unit   through with anti-freeze.    Leave the unit to dry for max. 1 minute.    Clean the fine filter.    Use the standard glycol-based anti-freezes   for cars.   – Unpressurize unit.   – Unscrew the fastening screw of the hood   and remove the hood.    Follow the handling instructions of the anti-   freeze manufacturer.   – Unscrew the cover with filter.   – Clean the filter with clean water or com-   pressed air.   Care and maintenance   – Reassemble in the reverse order.    Clean the filter at the suction hose for de-   tergent.   Danger!   ! Before any care and maintenance work   on the unit draw out the mains plug.   Annually or after 500 operating   hours   Caution!   When changing the oil, dispose of any   waste oil only at authorised collection points.    Change the oil   – For oil quantity and type see Technical   Specifications.   Safety inspection/Maintenance   contract   You can arrange with your dealer to have a   regular safety inspection carried out or to   have a maintenance contract. Please seek   advice.   – Undo the fastening screw, remove the   hood, unscrew the front oil drain plug on   the motor housing.   – Drain oil into a suitable container.   – Screw in the oil drain plug.   – Fill slowly with fresh oil; air bubbles have   to escape.   9 Download from Www.Somanuals.com. All Manuals Search And Download.   Operating Instructions HD 10/25 S VEX   English   Fault display   As and when required    Emptying and cleaning the detergent tank    1 x flashing red:   – High-pressure side leaking. Check high-   pressure hose, hose connections and   hand-held spray gun for leaks.   – Pull out the screw cap and hose for the   detergent tank.   – Place the unit on its rear.    2 x flashing red:   – Empty and clean the detergent tank.   – Motor too hot. Switch off the unit switch.   Leave unit to cool down. Switch the unit   back on again.   Troubleshooting    3 x flashing red:   – Fault in the power supply. Check the   mains connection. Check supply fuses.   Danger!   ! Before any repair work is undertaken,    4 x flashing red:   switch the unit off and pull out the power plug.   Have electrical components checked and re-   paired only by authorised Customer Service   personnel.   – Current consumption too high. Consult   Customer Service   For faults which are not identified in this chap-   ter, or when in doubt or when expressly in-   structed to do so, consult authorised   Customer Service personnel.   Unit does not work    Availability time has run out. The indicator   light will flash green. Switch the unit off and   then on again.   Indicator light    Check connecting cable for damage.   The indicator light shows the operating status   (green) and faults (red).    Consult Customer Service if there is an   electrical fault.   To reset:   Unit does not come up to pres-   sure    Switch off the unit switch.    Wait a moment.    Set nozzle to "high pressure".    Switch the unit back on again.    Clean/replace nozzle.   Operating status display    Constant green light:   – Unit is operational.    1 x flashing green:    Clean the fine filter, replace if required.    Evacuate air from the cleaner (see Switch-   ing on the unit).    Check water inlet volume (see Technical   Specifications).   – Operational readiness expired after   30 minutes.    Check all supply lines to the pump for leaks   or obstructions.   – The unit switched off after 30 minutes of   permanent operation (safety feature in   the case of a burst high-pressure hose).    Seek the help of Customer Service if nec-   essary.   10   Download from Www.Somanuals.com. All Manuals Search And Download.   English   Operating Instructions HD 10/25 S VEX   Pump is leaky   Spare parts    Three drops per minute are allowable and   can appear on the underside of the unit.   Seek the help of Customer Service if leaks   are more serious.   You will find a list of spare parts at the end of   these operating instructions.   Pump makes a knocking noise    Check all supply lines as well as the deter-   Warranty   gent system for leaks.   The warranty terms issued by our authorised   marketing company are valid in every country.   We remedy any fault in the unit free of charge   within the warranty period providing the cause   of the fault proves to be a material or manu-   facturing error.    Evacuate air from the cleaner (see Switch-   ing on the unit).    Clean the fine filter.    Seek the help of Customer Service if nec-   essary.   The warranty only becomes operative when   your dealer has completed the reply card ac-   companying the sale of the unit, has stamped   and signed it and you have then sent the reply   card to the marketing company in your coun-   try.   Detergent is not being drawn in    Set nozzle to "Chem".    Check detergent suction hose with filter for   leaks or obstructions and clean it if neces-   sary.   Should you wish to call upon the guarantee,   please apply to your dealer or nearest author-   ised Customer Service centre taking along   also the accessories and bill of sale.    Clean/renew non-return valve in detergent   suction-hose connection.    Open detergent metering valve or check it   for leaks/remove obstruction. Also clean   the venting orifice in the housing.    Seek the help of Customer Service if nec-   essary.   11   Download from Www.Somanuals.com. All Manuals Search And Download.   Operating Instructions HD 10/25 S VEX   English   Technical Specifications   HD 10/25 S VEX   Mains connection   Voltage   V 380   220   Type of current   Hz   kW   A 3~50   7.7   3~60   7.5   Connected load   Supply fuse (delayed-action, char. C)   Max. tolerable mains impedance   Extension cable 10 m   Extension cable 30 m   Water connection   16   25   Ω (0.145 + j0.090)   2 2 mm   mm   2.5   4 2.5   – Supply temperature max.   Supply volume min.   °C   60   1200 (20)   7.5   l/h (l/min)   m Supply hose – minimum length   Supply hose – minimum diameter   Suction height from an open container 20 °C   Supply pressure max.   Performance data   inches   m 3/4   0.5   MPa (bar)   1 (10)   Operating pressure   MPa (bar)   MPa (bar)   l/h (l/min)   l/h (l/min)   N 3–19 (30–190)   20.9 (209)   Max. operating overpressure (safety valve)   Flow rate   500–1038 (8.3–17.3)   0–80 (0–1.3)   62   Detergent intake   Recoil force of the handgun   Sound emission   Sound pressure level   (EN 60704-1)   dB (A)   dB (A)   72   87   Guaranteed sound pressure level   (2000/14/EC)   Vibrations of unit / total of vibration (ISO 5349)   2 Handheld gun   Spray lance   m/s   2.2   2.0   2 m/s   Dimensions   Length   mm   mm   mm   kg   l 560   500   1090   62   Width   Height   Weight without accessories   Reservoir capacity, detergent   Oil quantity, pump   Oil type, pump   6 l 1.2   SAE 90   12   Download from Www.Somanuals.com. All Manuals Search And Download.   Download from Www.Somanuals.com. All Manuals Search And Download.   |