Jotul Indoor Fireplace GZ 550 DV II User Manual

WARNING:  
IF THE INFORMATION IN THESE INSTRUC-  
TIONS ARE NOT FOLLOWED EXACTLY, A FIRE  
OR EXPLOSION MAY RESULT CAUSING PROP-  
ERTY DAMAGE, PERSONAL INJURY OR LOSS  
OF LIFE.  
FOR YOUR SAFETY:  
DO NOT STORE OR USE GASOLINE OR OTHER  
FLAMMABLE VAPORS AND LIQUIDS IN THE  
VICINITY OF THIS OR ANY OTHER APPLIANCE.  
Jøtul GZ 550 DV II  
Acadia  
INSTALLATION:  
INSTALLATION AND SERVICE MUST BE PER-  
FORMED BY A QUALIFIED INSTALLER, SER-  
VICE AGENCY OR LICENSED GAS SUPPLIER.  
Direct Vent Gas  
Fireplace  
WHAT TO DO IF YOU SMELL GAS:  
• DO NOT TRY TO LIGHT ANY APPLIANCE.  
• DO NOT TOUCH ANY ELECTRICAL  
SWITCHES.  
• DO NOT USE THE PHONE IN YOUR  
BUILDING. IMMEDIATELY CALL YOUR GAS  
SUPPLIER FROM A NEIGHBOR’S PHONE.  
• FOLLOW YOUR GAS SUPPLIER’S  
INSTRUCTIONS.  
• IF YOU CANNOT REACH YOUR GAS  
SUPPLIER, CALL THE FIRE DEPARTMENT.  
AVERTISSEMENT:  
ASSUREZ-VOUS DE BIEN SUIVRE LES IN-  
STRUCTIONS DANS CETTE NOTICE POUR  
REDUIRE AU MINIMUM LE RISQUE D’INCENDIE  
OU POUR EVITER TOUT DOMMAGE MATERIEL,  
TOUTE BLESSURE OU MORTALIT’E.  
NE PAS ENTREPOSER NI UTILISER D’ESSENCE  
NI OU LIQUIDES INFLAMMABLES DANS LE  
VOISINAGE DE CET APPAREIL OU DE TOUT  
AUTRE APPAREIL.  
Installation  
and  
L’INSTALLATION LE SERVICE DOIVENT  
ETRE EXECUTES PAR UN INSTALLATEUR  
QUALIFIE, AGENCE DE SERVICE OU LE  
FOURNISSEUR DE GAZ.  
Operation  
Instructions  
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE  
GAZ.  
• NE PAS TENTER D’ALLUMER L’APPAREIL  
• NE TOUCHEZ A AUCUM NTERRUPTEUR.  
• NE PAS VOUS SERVIR DES TELEPHONES  
SET TROUVANT DANS LE BATIMENT OU  
VOUS VOUS TROUVEZ.  
• APPELEZ IMMEDIATEMENT VOTRE  
FOURNISSEUR DE GAZ CHEZ UN VOISIN.  
SUIVEZ LES INSTRUCTIONS DU FOURNISSEUR.  
• SI VOUS NE POUVEZ REJOINDRE LE  
FOURNISSEUR DE GAZ, APPELEZ LE SER-  
VICE DES INCENDIES.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
Unpacking the Fireplace  
1. Before you remove the carton, remove the cast  
iron parts that are packed around the fireplace  
cabinet.  
Specifications ................................... 4  
Installation / Service Tools ............ 5  
General Information ....................... 5  
Safety Information .......................... 6  
Installation Requirements  
Framing ............................................ 6  
Mantel Clearances ........................ 8  
Hearth Protection ......................... 8  
Vent Requirements ....................... 9  
Vertical Termination ................... 10  
Horizontal Termination.............. 11  
Terminal Clearances.................... 11  
Vent Restrictor ............................. 12  
Fireplace Assembly  
2. Lift the shipping carton off of the fireplace  
cabinet.  
3. Unpack the Firebox. The Logset is packaged inside  
the firebox. Remove the Glass Panel Frame to  
unpack the firebox:  
Blower Installation...................... 12  
Gas Connection ............................ 14  
Gas Pressure.................................. 14  
High Altitude Adjustment ........ 15  
Fuel Conversion............................ 16  
Wall Thermostat .......................... 19  
Remote Control ............................ 19  
Antique Brick Kit .......................... 20  
Log Set Installation ..................... 21  
Surround Assembly..................... 22  
Double Door Installation ........... 22  
System Check................................ 23  
Operation......................................... 25  
Maintenance................................... 26  
Glass Replacement ........................ 26  
Service Log ....................................... 27  
Illustrated Parts Breakdown ....... 28  
Replacement Parts List................. 29  
Accessories ...................................... 30  
Lighting Instructions .... Back Cover  
• Locate the right and left spring latches on the  
underside of the firebox floor. Release each latch  
by pulling them forward to disengage the frame  
body.  
• Pull the Glass Frame away from the firebox and  
lift to disengage it from the three steel tabs  
located at the top of the firebox. Set the glass out  
of the way.  
Do not unpack the logs until you are ready to  
install them.  
Spring Latches  
BLOWER  
BURNER  
IGNITOR  
ON  
HI  
MANUAL  
OFF  
MANUAL  
OFF  
AUTO  
AUTO  
OFF  
LO  
HI  
LO  
Pull each Spring Latch to disengage them from the  
Glass Frame.  
PLEASE READ THESE INSTRUCTIONS IN  
THEIR ENTIRETY AND MAKE THEM  
AVAILABLE TO ANYONE USING OR  
SERVICING THIS APPLIANCE.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Jøtul GZ 550 DV II Acadia  
Direct Vent Gas Fireplace  
Manufactured and Distributed by:  
Jøtul A.S.A.  
Fredrikstad, Norway  
Jøtul North America  
Portland, Maine  
Test Standards  
THIS HEATER MUST BE INSTALLED AND  
MAINTAINED BY A QUALIFIED SERVICE  
AGENCY.  
This appliance complies with  
National Safety standards  
and is tested and listed by  
Intertek Testing Services of  
Middleton, Wisconsin to ANSI  
Z21.88-2002•CSA 2.33-M02  
and CAN/CGA 2.17--M91,  
CSA P.4.-01.2 for Canada.  
IN THE COMMENWEALTH OF  
MASSACHUSETTS, THIS PRODUCT  
MUST BE INSTALLED BY A LICENSED  
PLUMBER OR GAS-FITTER.  
DO NOT ATTEMPT TO ALTER OR  
MODIFY THE CONSTRUCTION OF THIS  
APPLIANCE OR ITS COMPONENTS. ANY  
MODIFICATION OR ALTERATION WILL  
VOID THE WARRANTY, CERTIFICATION  
AND LISTING OF THIS APPLIANCE.  
DO NOT ATTEMPT TO ALTER OR MODIFY THE CON-  
STRUCTION OF THE APPLIANCE OR ITS COMPONENTS.  
ANY MODIFICATION OR ALTERATION WILL VOID THE  
WARRANTY, CERTIFICATION AND LISTING OF THIS  
APPLIANCE.  
Specifications  
Input Rates  
Natural Gas  
28,000 BTU/hr. maximum input  
16,000 BTU/hr. minimum input  
Propane  
28,000 BTU/hr. maximum input  
15,500 BTU/hr. minimum input  
Inlet Pressure:  
MIN  
Natural Gas: 5.0 WC (1.24 kPa)  
Propane: 12.0 WC (2.98 kPa)  
MAX  
We at Jøtul North America are dedicated to  
manufacturing the finest quality hearth  
products you can be assured will give you  
many years of safe, dependable service.  
11.0 WC (2.74 kPa)  
14.9.0 WC (3.71 kPa)  
Manifold Pressure: MIN  
Natural Gas: 1.2 WC (.29 kPa)  
MAX  
3.8 WC (.94 kPa)  
11.0 WC (2.74 kPa)  
Propane:  
2.9 WC (.72 kPa)  
To ensure your confidence, we recommend  
that whenever possible, our products be  
installed and serviced by professionals who  
are certified by the National Fireplace  
Institute (NFI) or, in Canada, by Wood Energy  
Technical Training (WETT).  
THIS FIREPLACE IS SHIPPED AS A  
NATURAL GAS FIREPLACE ONLY. IF  
USE WITH PROPANE IS DESIRED,  
THE FIREPLACE MUST BE CON-  
VERTED TO USE WITH PROPANE.  
FOR YOUR CONVENIENCE THIS  
FIREPLACE IS SHIPPED WITH A  
PROPANE CONVERSION KIT.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. DO NOT OPERATE THIS FIREPLACE IF ANY PART HAS  
BEEN UNDER WATER.  
General Information  
Immediately call a qualified service technician to  
inspect the heater and to replace any part of the  
control system and any gas control which has  
been under water.  
IMPORTANT:  
SAVE THESE INSTRUCTIONS.  
Ne pas se servir de cet appareil s’il a ete’ plonge  
dans l’eau, completement ou en partie. Appeler  
un technicien qualifie pour inspecter l’appareil et  
remplacer toute partie du syste’me de controle et  
toute commande qui ont ete plonges dans l’eau.  
THIS HEATER MUST BE INSTALLED AND  
MAINTAINED BY A QUALIFIED SERVICE  
AGENCY.  
DO NOT ATTEMPT TO ALTER OR  
MODIFY THE CONSTRUCTION OF THIS  
APPLIANCE OR ITS COMPONENTS. ANY  
MODIFICATION OR ALTERATION WILL  
VOID THE WARRANTY, CERTIFICATION  
AND LISTING OF THIS APPLIANCE.  
5. Do not operate the fireplace with the glass front  
removed, cracked or broken. Replacement of the  
glass should be done by a licensed or qualified  
service person. Only remove glass for routine  
service. Always handle glass carefully.  
Pour utilisation avec les portes en verre cerifiers  
aved l’appareil seulemend ou. Ne pas utiliser avec  
des portes on verre.  
1. The installation and repair of this appliance must  
be done by a qualified service person. Failure to  
properly install and maintain this heater could  
result in an unsafe or hazardous installation,  
which may result in a fire, explosion, property  
damage, personal injury or loss of life.  
6. Notify your insurance company before proceding  
with installation of this fireplace.  
7. This appliance may be installed in an aftermarket  
permanently located, manufactured (mobile)  
home, where not prohibited by local codes. This  
appliance is only for use with the type(s) of gas  
indicated on the rating plate. This appliance is not  
convertible for use with other gases, unless a  
certified kit is used.  
2. This appliance should be inspected before use  
and at least annually. More frequent cleaning  
may be required due to excessive lint from  
carpeting, bedding material, etc. It is imperative  
that control compartments, burners and circulat-  
ing air passageways of the appliance be kept  
clean.  
Cet appareil peut être installé dans un maison  
préfabriquée (mobile) déjà installée à demeure si  
les règlements locaux le permettent. Cet appareil  
doit être utilisé uniquement avec les types de gas  
indiqués sur la plaque signalétique. Ne pas  
l’utiliser avec d’autres gas sauf si un kitde conver-  
sion certifié est installé.  
`S’assurer que le bruleur et le compartiment des  
commandes sont propres. Voir les instructions  
d’installation et d’utilisation qui accompagnent  
l’appareil.  
3. The installation must conform to local codes. Your  
local Jøtul authorized dealer can assist you in  
determining what is required in your area for a  
safe and legal installation. Some areas require a  
permit to install a gas burning appliance. Always  
consult your local building inspector or authority  
having jurisdiction to determine what regulations  
apply in your area.  
Suggested Tools for  
Installation and Service  
• External regulator (for Propane only)  
• Piping which complies with local code  
• Manual shutoff valve - T-Handle in MA  
• Sediment trap - if required by code  
• 10mm open end wrench  
In the absence of local codes, the installation  
requirements must comply with the current  
National codes. In the U.S., these requirements  
are established in the National Fuel Code, ANSI  
Z223.1.(NFPA 54). In Canada, the codes have been  
established in CAN/CGA B149 Fuel Installation  
Code.  
• 1/2”, 7/16” open end wrench  
• Phillips head screwdriver  
• Flat head screwdriver •Tee joint  
• Pipe wrench  
•Pipe sealant  
• 1/4” nut driver  
• Gloves  
•Torx T20 screwdriver  
•Safety glasses  
•Power Drill  
Installer l’appareil selon les codes ou reglements  
locaux, ou, en l’absence de tels reglements, selon  
les Codes d’installation CAN/CGA-B149.  
• Leak test solution  
• Reciprocating Saw  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Safety Information  
Due to the high operating temperatures this  
appliance should be located out of traffic and  
away from furniture, draperies, etc. Maintain  
proper clearance to combustible mantels and  
fireplace trim.  
Requirements  
The GZ 550 DV Acadia Gas Fireplace and its vent  
system must be installed within a totally enclosed  
structure. The fireplace must be connected to the  
specified vent and termination cap outside the  
building. Do not vent into another room or inside  
any part of a building. Under no circumstances may  
the flow of combustion or ventilation air be ob-  
structed.  
Children and adults should be alerted to the  
hazards of high surface temperatures and should  
stay away to avoid burns or clothing ignition.  
Young children should be supervised while they  
The approved vent configurations described  
herein are derived from extensive testing under  
controlled laboratory conditions. Gas appliance  
performance can be negatively affected by variables  
present in the installation environment, i.e: strong  
prevailing winds, steep roofs, nearby trees, snow  
accumulation, etc. These conditions should be taken  
into consideration by the installer and home owner.  
In such instances, system performance can often be  
improved by an increase in the vent height or  
installation of a high wind termination cap.  
are in the same room as the Acadia gas fireplace.  
Surveiller les enfants. Garder les vetements, les  
meubles, l’essence ou autres liquides a vapeur  
inflammables loin de l’appareil.  
Clothing or other flammable materials should not  
be placed ON or NEAR the Acadia gas fireplace.  
Never allow any to use the fireplace if they are  
unfamiliar with its operation.  
NEVER store or use gasoline or any other flam-  
mable vapors or liquids in the vicinity of the  
Acadia gas fireplace.  
Placement and Framing  
The combustible framing members of the fireplace  
enclosure may be placed in direct contact with the  
fireplace cabinet as specified in the illustrations on  
the following pages. Use the standoffs integrated  
into the sides and top of the front opening to locate  
a combustible header and side framing members as  
shown in the illustrations. See fig. 1.  
Never burn any solid materials (wood, cardboard,  
paper, coal, etc.) in this gas fireplace. Use with  
natural gas or propane fuel ONLY.  
Any safety screen, glass or guard removed for  
servicing the appliance must be replaced prior to  
operating the appliance.  
Do not slam or strike the glass panel.  
Electrical Power: If the optional Blower (#155630)  
will be used, be sure to include provision for a  
properly grounded, 120 volt house current outlet at  
the fireplace structure.  
Wear gloves and safety glases while performing  
maintenance procedures.  
Electrical Hazard  
Parallel Installation  
Be aware of electrical wiring locations when  
Although it is possible to place combustible framing  
members in direct contact with the rear surface of  
the cabinet, the fireplace must be located forward  
of the back wall with adequate clearance to accom-  
modate the vent adaptor and subsequent lengths  
of vent pipe. Consideration must also be given to  
maintaining a minimum 1 inch (25 mm) clearance  
between a vertical vent pipe and any combustible  
materials to the rear of the unit. See Figs. 2, 3, and 4.  
cutting holes in walls and ceilings for termination.  
The optional Acadia Blower (155630) must be  
electrically grounded in accordance with local  
codes or, in the absence of local codes, with the  
current ANSI/NFPA 70, National Electrical Code or  
CSA C22.1-Canadian Electrical Code.  
The Acadia Blower is supplied with a three-prong  
(grounding) plug for protection against shock  
hazard and should be plugged directly into a  
properly grounded three-prong receptacle. DO  
NOT CUT OR REMOVE THE GROUNDING PRONG  
FROM THE PLUG.  
Corner Installation  
A corner installation will require that the Vent  
Adaptor be installed in a top exit position. Horizontal  
terminations will then require use of a 90° elbow.  
Figs. 5 and 5a show rear termination with 5/8  
Simpson Dura-Vent Wall Thimble #1247.  
Always disconect the power supply when per-  
forming routine service on the fireplace.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
25”  
635 mm  
Figure 1. Cabinet Dimensions.  
Figure 2. Minimum horizontal vent  
allowance through wall.  
16 1/4”  
410 mm  
A
5/8 Vent Adaptor  
Header Standoff Height: 36 1/2”  
35 3/4”  
900 mm  
6” Vent  
Section  
Wall Cutout :  
4/6 Pipe - 10”x10”  
5/8 Pipe - 11”x11”  
Observe all vent  
and termination  
clearance  
36 1/2”  
921 mm  
35”  
890 mm  
35 3/4*  
910 mm  
requirements.  
Security Vent:  
38”  
8”  
200 mm  
4”  
100 mm  
970 mm  
A = 25 1/4” (645 mm)  
Security Termination has no slip adjustibility.  
NOTE: DO NOT INSTALL CABINET ON FLOOR SURFACE  
LOWER THAN THE FRONTAL HEARTH SURFACE.  
* Wallboard Standoff Height  
Simpson DuraVent and Amerivent:  
A = 25 3/4” (660 mm)  
Rear Exit  
Top Exit  
16 1/4”  
(415 mm)  
16 1/4”  
(415 mm)  
A
38 3/4”  
(990 mm)  
38”  
(970 mm)  
32 3/4”  
(830 mm)  
Horizontal Vent: Minimum depth accomodates the length of  
Vent Adaptor and one 6’ vent section through wall construction.  
16 1/4”  
21 1/2”  
Vent Adaptor:  
5/8  
5/8 Vent  
4/6 Vent  
(413 mm)  
(546 mm)  
A =  
21 3/4”  
20”  
(510mm)  
Vertical Vent: Minimum depth includes 1 inch clearance  
between Vent Adaptor and combustible wall construction.  
Figure 4. Vent Adaptor orientation.  
Vent Adaptor:  
5/8  
21 1/2”  
4/6  
20”  
Min. Vent  
Clearance  
A =  
WALL OPENING  
5/8 VENT  
Figure 3. Depth requirement to rear wall.  
CUSTOM  
MANTEL  
CABINET  
11” x 11”  
280 mm x 280 mm  
See text for  
details.  
2”  
50 mm  
9”  
230 mm  
48 1/2”  
1232 mm  
41”  
1041 mm  
49 1/4”  
1232 mm  
Minimum  
mantel  
shelf  
28 1/2”  
730 mm  
43”  
1092 mm  
height to  
cover vent  
wall  
16”  
410 mm  
thimble  
56 1/2”  
1435 mm  
Figure 5. Corner framing dimensions.  
Figure 5a. Corner Installation - 5/8 vent, rear termination.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hearth Protection  
The GZ550 Acadia is approved for installation  
without hearth protection. Combustible materials  
may be used on the floor directly under and in front  
of the fireplace. NOTE: The floor surface under the  
unit must be level with, or higher than, the surface  
in front of the unit to allow the fireplace Controls  
Door to fully open.  
Mantel and Trim Clearance  
12” 8”  
4”  
13 1/2”  
10 1/2”  
MANTEL  
AREA  
DRYWALL  
12”  
9”  
UPPER TRIM  
2 1/2” Max. Depth  
7 1/2”  
4 1/2”  
Facing and Clearance Requirements  
HEADER  
The following clearance and hearth specifications  
are the minimum requirements for the GZ550  
Acadia gas fireplace. Measure clearances from the  
steel fireplace cabinet - not the cast iron surround  
panels. See Figures 6 - 8.  
STANDOFF  
TOP OF CABINET  
A combustible surface is anything that can burn  
(i.e. sheet rock, wallpaper, wood, fabrics etc.). These  
surfaces are not limited to those that are visible and  
also include materials that are behind non-combus-  
tibles.  
35”  
If you are not sure of the combustible nature of  
a material, consult your local fire officials. “Fire  
Resistant” materials are considered combustible -  
they are difficult to ignite, but will burn. “Fire-  
rated” sheet rock is also considered combustible.  
Maintain the proper clearances to the appliance  
to allow adequate flow of ventilation air around  
the fireplace.  
Figure 7. Minimum Mantel Clearances. Measure  
clearances from the top of the fireplace cabinet  
before installation of the cast iron surround panels.  
Wallboard  
Header  
TOP TRIM  
Standoff  
4 1/2”  
1.2 cm  
GZ550 DV  
Cabinet  
4 1/2”  
1.2 cm  
Standoffs  
10”  
2.55 cm  
Figure 8. Minimum Side Wall and Trim Clearance.  
Measured from the cabinet, not standoffs or cast iron  
panels.  
10”  
(250 mm)  
Figure 6. Header and Side Standoffs  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vent Requirements  
The GZ550 DV Acadia Gas Fireplace is approved for  
use with direct vent components produced by the  
following manufacturers:  
• Simpson Dura-Vent Corporation, 5/8 and 4/6 pipe  
• Security Vent Ltd. International, 5/8 and 4/6 pipe  
• Amerivent Corporation, 4/6 pipe  
Horizontal Overhang  
18”.  
min.  
18”.  
min.  
Lowest Discharge  
Opening  
• Selkirk Metalbestos Corp. MDV Direct Vent Systems  
Termination  
Cap  
Use vent components from a single vent manu-  
facturer. Do not combine parts from different  
manufacturers in a single installation.  
18” min.  
The vent termination must fall within the shaded area  
designated in the diagrams in Figures 12 - 14.  
Venting Guidelines  
The minimum height for a vertical termination  
cap must be no less than 7' from the top of the  
unit. The maximum height must not exceed 35'.  
Figure 10. Gas Vent Height Rule: Vertical vent  
termination height above roof.  
The minimum vent height above the roof or  
adjacent walls is specified by major building  
codes. Use the Gas Vent Rule as a general guide.  
See fig.10. requirements of the approval listing  
and the manufacturer’s instructions.  
Do not recess the vent terminal into a wall or siding.  
Inspect the vent system annually for blockage and  
deterioration. If the vent-air intake system is  
disassembled for any reason, reinstall according to  
the instructions provided for initial installation.  
Clearance (airspace) between Vent and Combustibles:  
Top - 2” (51 mm)  
Sides/Bottom - 1” (25 mm)  
Installation of any components not manufactured  
or approved by Jøtul or failure to meet all clear-  
ance requirements will void all warranties and  
may result in property damage, bodily injury, or  
loss of life.  
Wall Cutout Dimensions:  
4/6 Pipe - 10” x 10”  
5/8 Pipe - 11” x 11”  
Any horizontal run must rise 1/4” per foot.  
Install venting in accordance with the vent  
manufacturers’ instructions. Never modify any  
venting component, or use any damaged venting  
product.  
IN DESIGNING THE VENT SYSTEM, DO NOT  
COUNT THE 45° ELBOW CONNECTED TO THE  
VENT COLLAR AS AN ELBOW.  
THE GAS APPLIANCE AND VENT SYSTEM MUST BE  
VENTED DIRECTLY TO THE OUTSIDE OF THE BUILDING.  
DO NOT CONNECT VENT TO A  
45° Elbow  
6” Vent Section  
CHIMNEY SERVING A SOLID FUEL  
OR ANOTHER GAS APPLIANCE.  
Wall Support  
Joint Sealing Requirement:  
Apply a 1/8” bead of high-  
temperature (750°F) sealant  
S
to the male section of the  
inner vent pipe. See fig. 9.  
The cement should seal  
the inner pipe from the  
outer pipe.  
E
A
L
A
N
T
Wall Termination  
Figure 11. Typical minimum horizontal vent  
configuration - 5/8 Simpson DuraVent. Do not use  
4/6 pipe in this configuration.  
Figure 9. Seal each inner joint before joining pipe.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
35  
35  
Restrictor  
Fully Closed  
Restrictor  
Fully Closed  
30  
30  
Restrictor  
2/3 Closed  
Restrictor  
2/3 Closed  
18  
18  
Restrictor  
1/3 Closed  
Restrictor  
1/3 Closed  
10  
10  
9
9
7
Restrictor  
Open  
Minimum 7  
Height  
Both  
5/8 Vent  
4/6 Vent  
Restrictor  
Open  
Max.Two  
Elbows -  
90° or 45°  
Max.Two 45°  
Elbows  
10  
12  
10  
5
12  
7
Horizontal Run in Feet  
Horizontal Run in Feet  
Figure 12. Vent Window for vertical termination  
using 5/8 or 4/6 pipe.  
Figure 13. Vent Window for offset vertical  
termination using 5/8 or 4/6 pipe.  
Vertical Termination  
Figure 14. Minimim  
centerline for  
horizontal  
termination of 4/6  
pipe  
The vent must terminate within the shaded area  
designated on the graphs in Figs. 12 and 13.  
• Maximum Elbows - Two 90° or Two 45° (Do not  
count the first elbow off the vent collar.)  
• Use the restrictor settings indicated in the graph  
as general guide. The specific characteristics of  
your installation may require different settings.  
52”  
(990 mm)  
Horizontal Termination  
The vent must terminate within the shaded area  
designated in Figs. 15 and 16. (Do not count the first  
elbow off the vent collar.)  
• Max. Elbows - One 90° or one 45°.  
• Use of 4/6 pipe requires a minimum 1 foot rise. Fig. 16.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12  
9
12  
9
5
5
1
Max. One 90°  
Elbow  
Max. One 90°  
Elbow  
10  
5
10  
5
12  
3
12  
3
Horizontal Run in Feet  
Horizontal Run in Feet  
Figure 15. Horizontal termination -5/8 pipe.  
Figure 16. Horizontal Termination - 4/6 Pipe.  
Minimum 1 ft. rise required.  
Horizontal Termination Clearance  
Figure 17. Vent Terminal Clearances - National Fuel Gas Code.  
A = Clearance above grade, veranda, porch , deck, or  
balcony : *12 inches (30 cm) minimum.  
G = Clearance to inside corner: Min. 6 inches, U.S. / *12  
inches (30 cm) CAN. We strongly recommend 12 inches,  
particularly where windy conditions pevail.  
B = Clearance to window or door that may be opened:  
Min. 9 inches, U.S. / *12 inches (30 cm) CAN.  
We recommend 12in. minimum to prevent condensa-  
tion on the window.  
H = *Not to be installed above a meter/regulator assembly  
within 3 feet (90 cm) horizontally from the center-line  
of the regulator.  
C = Clearance to permanently closed window:  
Min. 9 inches, U.S. / *12 inches (30 cm) CAN  
We recommend 12in. minimum to prevent condensa-  
tion on the window.  
I = Clearance to service regulator vent outlet:  
3 feet, U.S. / 6 feet (1.8 m), CAN.  
J = Clearance to nonmechanical air supply inlet to building  
or the combustion air inlet to any other appliance:  
*12 inches (30 cm) minimum.  
D = Vertical clearance to ventilated soffit located above  
the terminal within a horizontal distance of 2 feet (60 cm)  
from the centerline of the terminal: 18 inches  
(46 cm) minimum.  
K = Clearance to a mechanical air supply inlet: *6 feet  
(1.8 m) minimum.  
L = ** Clearance above paved sidewalk or a paved driveway  
located on public property: *7 feet (2.1 m) min.  
E = Clearance to unventilated soffit: *12 inches (46 cm)  
minimum.  
M = Clearance under veranda, porch, deck, or balcony:  
F = Clearance to outside corner: Min. 9 inches, U.S. / *12  
inches (30 cm) CAN. We strongly recommend 12 inches,  
particularly where windy conditions pevail.  
*12 inches (30 cm) minimum. 1  
** A vent shall not terminate directly above a sidewalk or driveway  
which is located between two single family dwellings and serves  
both dwellings.*  
*
As specified in CGA B149 Installation Codes. Note: Local Codes  
and Regulations may require different clearances.  
1
Only permitted if veranda, porch, deck, or balcony, is fully open  
on a minimum of two sides beneath the floor.*  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fireplace Installation  
Optional Blower  
Install the optional Blower (155630) before  
installing the gas supply line.  
Figure 18.  
Wall Vent Terminal /  
Overhang Clearances  
2 1/2”  
12 ”  
305  
mm  
64 mm  
3”  
76 mm  
Power Requirement  
The blower must be electrically grounded in accor-  
dance with local codes or, in the absence of local  
codes, with the current NFPA 70- National Electrical  
Code or CSA C22.1-Canadian Code.  
Variable Vent Restriction  
Vent restriction is accomplished by sliding a restric-  
tor panel over the combustion air intake ports  
located at the back of the firebox. See Fig 19. The  
panel is set in a fully open position at the factory.  
Use the Vent Window diagrams in Figs. 12-13 as a  
starting point to determine the best restriction  
setting. Follow these steps to adjust the restriction  
as necessary:  
A three-prong (grounding) power supply plug is  
included for protection against shock hazard and  
should be plugged directly into a properly grounded  
three-prong receptacle. DO NOT CUT OR REMOVE  
THE GROUNDING PRONG FROM THE PLUG.  
Blower Function  
In the Auto mode, the blower is controlled by a heat  
activated switch (snapstat) that will turn the fan on  
and off as the firebox heats and cools. Use the  
Manual mode to over-ride the snapstat. If the blower  
is not needed, place the blower control switch in the  
OFF position and the snapstat will not function.  
1. Remove the Controls Panel to access the adjust-  
ment lever at the rear of the valve compatment.  
Simply loosen the two wingnuts that secure the  
panel to the cabinet floor and pull the panel  
forward. You do not need to disconnect any wires.  
CAUTION: Always unplug the Blower when  
performing any routine service to the Acadia gas  
fireplace.  
2. Locate the vent restriction wingnut protruding  
from the firebox floor at the rear of the valve  
compartment. Loosen the wingnut and push the  
lever to the left to increase restriction in one inch  
increments, e.g: 1 inch travel = 1/3 closed position.  
Installation  
1. Loosen the two wingnuts that secure the Control  
Panel to the fireplace floor. Pull the panel forward  
and swing it to the right to access the rear of the  
cabinet. Do not disconnect any wires.  
The ideal restrictor setting for a particular vent  
system will vary depending on the specific installa-  
tion characteristics. Once the fireplace is operating,  
further restrictor adjustment may be necessary to  
obtain the best performance. See the Operation  
chapter of this manual for more information.  
2. Insert a rubber grommet at each corner of the  
Base Plate as shown in fig. 20.  
3. Engage the Blower unit base with the four studs  
at the rear of the fireplace cabinet floor. See fig. 21.  
Fully Closed  
2/3 Closed  
4. Insert the Snapstat into the slot in the Snapstat  
Bracket and, using the M6 nuts and 10 mm socket,  
attach the Control Switch / Snapstat Bracket to  
the two studs protruding from the firebox floor.  
See fig. 22.  
1/3 Closed  
Full Open  
5. Connect the Blower Wire harness to the switch  
connector at the back of the Control Panel and  
two other leads to either terminal on the  
snapstat.  
BLOWER  
BURNER  
IGNITOR  
ON  
HI  
MANUAL  
OFF  
M
6. Run the power cord to the duplex receptacle in  
the side of the cabinet. Gather slack cord into the  
side cavity, away from the plumbing and other  
wiring. Reposition and secure the Control Panel.  
AUTO  
OFF  
LO  
HI  
LO  
Figure 19. Vent restrictor adjustment.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
Final Cabinet Positioning  
1
1. If appropriate, attach the 4/6 Vent Adaptor  
Collar:  
2
• Remove the 5/8 Collar supplied with the unit.  
• Align the 4/6 Collar as shown in fig. 23 and  
secure to the unit using the original screws. Be  
sure the single round fastener hole is oriented to  
the 12 o-clock position for proper vent align-  
ment.  
4
5
3
6
1. #129374 Fan/Motor Unit- 125 cfm., variable speed  
2. #220012 Base Plate  
3. #220637 Snapstat (140°F - 120°F)  
4. #220989 Snapstat Bracket  
1. Side Standoffs: Remove the retainer screws. Using  
vise grips or pliers, fold each standoff at the  
perforations. Secure each standoff using the  
screws previously removed. See fig. 24.  
5. #220055 Rubber Grommets, 4  
6. #9930 M6 Hex Flange nuts, 2  
Figure 20. Blower Kit 155630 contents.  
2. Wall Stud Brace: Loosen, bend, and position each  
cabinet Retainer Strap for attachment to the  
fireplace enclosure. See fig. 24.  
3. Locate the fireplace cabinet in its final position  
within the enclosure. Confirm that the first 45°  
Elbow is correctly aligned for final vent assembly  
and secure it to the Vent Collar using 3, #10 sheet  
metal screws.  
4. Confirm that the cabinet is positioned to align its  
forward edge with the finished surface of the  
wall facing. The stud braces allow approximately  
2 inches of forward adjustment to accommodate  
most any facing thickness. Secure the braces to  
the enclosure frame.  
Figure 21. Blower location.  
5. Complete the gas line and electrical power  
routing as appropriate for blower and thermo-  
stat functions.  
Snapstat Bracket  
BLOWER  
BURNER  
IGNITOR  
ON  
HI  
MANUAL  
OFF  
MANU  
OFF  
Standoff in shipping position.  
AUTO  
AUTO  
OFF  
LO  
HI  
LO  
Figure 22. Install snapstat bracket and switch box.  
Remove, bend and  
reattach each Standoff.  
For correct vent pipe  
alignment, be sure the  
round hole is oriented to  
the 12- o’clock position  
Remove, bend and  
reattach each Wall  
Stud Brace.  
Figure 23. 4/6 Vent Collar orientation.  
Figure 24. Standoff and Stud Brace orientation.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connect the Gas Supply  
Leak test:  
• Mix a 50-50 solution of water and dish soap.  
Gas Supply Requirements  
• Light appliance- see lighting instructions on page  
23 of this manual or on the fireplace’s rating  
plate.  
ALL INSTALLATIONS MUST COMPLY WITH LOCAL  
CODE OR IN THE ABSENCE OF LOCAL CODE, MUST  
COMPLY WITH THE MOST RECENT EDITION OF THE  
NATIONAL FUEL GAS CODE ANSI Z223.1/NFPA 54 OR  
CAN-B149.  
• Brush or spray all joints and connections with the  
soapy water solution.  
• If bubbles appear at any connection or seam or a  
gas odor is detected, immediately turn gas  
control knob to the OFF position.  
Shutoff Valve  
All codes require a gas shutoff valve (gas cock)  
and union to be installed in the supply line and in  
the same room as the appliance. This allows for the  
disconnection of the fireplace for servicing and  
maintenance. See fig. 25.  
Tighten or reconnect the leaking joint and retest  
for any gas leaks.  
A T-handle gas shutoff valve is required in  
Massachusetts in compliance with Code 248CMR.  
The fireplace and gas control valve must be  
disconnected from the gas supply piping during any  
pressure testing of the system at test pressures in  
excess of 1/2 psig. For pressures lower than 1/2 psig,  
isolate the gas supply by closing the manual shutoff  
valve.  
Control Valve Connection  
The gas supply line connection is made to the  
left side of the valve. The gas supply line should be a  
minimum 3/8" diameter, or the appropriate size to  
provide sufficient gas pressure to the valve regard-  
less of the input setting.  
Figure 25. Gas supply line fittings.  
Gas Pressure  
The use of flexible gas appliance connectors is  
acceptable in many areas in the U.S. In Canada,  
methods vary depending on local code. If local codes  
permit, use flexible gas line for ease of installation  
and service. For those locales where flexible gas  
lines are not permitted, use the 3/8” iron fitting to  
make the connection at the left side of the Control  
Valve. See Figures 25 and 26.  
Proper gas pressure provides a consistent flow  
of gas to the appliance and is instrumental in  
checking for gas leaks. The gas control valve on the  
fireplace is equipped with pressure test points for  
gauge connections. The gauge connections are  
located on the front of the valve under the On/Off/  
Pilot knob. Gauge connections are identified by:  
• IN/E for inlet or supply pressure (the amount of  
Secure all joints tightly using appropriate tools  
and sealing compounds (for propane units, be sure  
to use compounds that are propane resistant). Turn  
on gas supply and test for gas leaks using a soapy  
water solution. Never use an open flame to check  
for leaks.  
gas coming to the valve.)  
• OUT/A for manifold pressure (the amount of gas  
that is coming out of the valve to the burner.)  
E
A
Figure 26. Pressure test point as located on the  
front of the valve.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DANCE WITH THE MANUFACTURER’S INSTRUCTIONS  
AND ALL CODES AND REQUIREMENTS OF THE  
AUTHORITY HAVING JURISDICTION. THE INFORMA-  
TION STICKER MUST BE COMPLETED BY THE IN-  
STALLER AND APPLIED TO THE APPLIANCE AT THE  
TIME OF THE CONVERSION. THE QUALIFIED SERVICE  
AGENCY PERFORMING THIS WORK ASSUMES RE-  
SPONSIBILITY FOR THIS DERATING.  
The appliance must be isolated from the gas  
supply line by closing its individual manual gas  
shutoff valve (gas cock) during any pressure testing  
of the gas supply piping system that is equal to or  
less than pressures of 1/2 psig (3.5 kPa).  
Inlet Pressure  
MIN  
MAX  
Natural Gas: 5.0 WC (1.24 kPa) 11.0 WC (2.74 kPa)  
In Canada: This unit has been tested for installation  
at high altitudes in accordance with Canadian test  
standard CAN/CGA-2.17. THE DERATING SHALL BE  
CARRIED OUT IN ACCORDANCE WITH THE REQUIRE-  
MENTS OF THE PROVINCIAL AUTHORITIES HAVING  
JURISDICTION AND IN ACCORDANCE WITH THE  
REQUIREMENTS OF THE CAN1-B-149.1 AND .2  
INSTALLATION CODE.  
Propane:  
12.0 WC (2.98 kPa) 14.9 WC (3.71kPa)  
Manifold Pressure  
MIN  
Natural Gas: 1.2 WC (.29 kPa)  
Propane: 2.9 WC (.72 kPa)  
MAX  
3.8 WC (.94 kPa)  
11.0 WC (2.74 kPa)  
ALWAYS TEST PRESSURE WITH VALVE CONTROL KNOB  
SET ON HIGH. Symptoms of incorrect gas pressure  
include:  
Derating Procedure  
1. Follow Steps 1-4 of the Fuel Conversion procedure  
outlined on page 14.  
2. Remove the original orifice. Consult Table 1 to  
determine the correct orifice size for your eleva-  
tion and fuel type. Install the appropriate orifice  
included in the high altitude kit.  
3. Fill out the high altitude conversion label and  
attach to the rating plate or fireplace cabinet floor  
See Figure 27.  
4. Reassemble the firebox components.  
5. It may be necessary to adjust the air shutter on  
the burner tube. See the AIR SHUTTER/FLAME  
APPEARANCE section of this manual for more  
details.  
Insufficient gas pressure:  
• Small pilot flame which can result in insufficient  
millivolts.  
• Little variation in flame picture between HI and  
LO settings.  
• Insufficient gas to support more than one appli-  
ance causing nuisance outages or gas surges.  
Excessive gas pressure:  
• Permanent damage to valve causing complete  
appliance shut down.  
Too large a pilot flame resulting in overheating of  
the power generator and consequent shut down.  
• Sooting due to impingement and/or incorrect fuel  
to air mix.  
High Altitude Orifice Chart  
High Altitude Adjustment  
Orifice  
Size  
Elevation  
Fuel  
Part No.  
Installations located at altitudes from 2000 - 4500 ft.  
(610 M - 1370 M), require compensation for the  
thinner air (less volume of air per cubic foot). Higher  
altitudes affect the atmospheric pressure and heat  
value of gaseous fuels. The lower oxygen content in  
the air and the lower gas viscosity require the use of  
a different orifice to achieve efficient, clean combus-  
tion at the burner tube.  
0 - 2000 ft.  
(0 - 610 m)  
Natural Gas  
Propane  
#38  
1.55 mm  
129130  
220048  
2001 - 4500 ft.  
(611 - 1370 m)  
Natural Gas  
Propane  
#39  
1.50 mm  
129367  
129146  
Table 1. High Altitude Orifice Chart.  
THIS STOVE HAS BEEN CONVERTED FOR USE AT AN  
ALTITUDE OF: ________________  
For high altitude installations consult the local  
gas distributor or the authority having jurisdiction  
for proper rating methods. If the installer must  
convert the unit to adjust for varying altitudes, use  
Jøtul High Altitude Kit (#155610-NG / #155611-LP).  
Orifice Size: ____________ Manifold Press. _____  
Input Btu/Hr. ___________ Fuel Type __________  
Date of Conversion ___________  
In the U.S: THE DERATING KIT MUST BE INSTALLED  
BY AN AUTHORIZED SERVICE TECHNICIAN IN ACCOR-  
Figure 27. High Altitude Conversion Label.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fuel Conversion  
The GZ550 DV Acadia Fireplace is designed to for use  
with either Natural gas or Propane. It is shipped  
from the factory configured to use Natural gas. A  
conversion kit is included for conversion to Propane  
use if desired. Check the identification label on the  
Control Valve to confirm that the correct fuel is used.  
Tools required:  
1/4” Nut driver, 7/16” and 1/2” open end wrench or  
deep well socket, 4 mm allen wrench, Torx t20 or  
slotted screwdriver.  
Conversion Kit Contents:  
WARNING:  
• 1 Regulator Tower labeled for Propane  
• 3 Regulator Tower Screws  
THE CONVERSION KIT IS TO BE IN-  
STALLED BY AN AUTHORIZED JØTUL  
SERVICE TECHNICIAN IN ACCORDANCE  
WITH THE MANUFACTURER’S INSTRUC-  
TION AND ALL CODES AND REQUIRE-  
MENTS OF THE AUTHORITY HAVING JU-  
RISDICTION. FAILURE TO FOLLOW THESE  
INSTRUCTIONS COULD RESULT IN SERI-  
OUS INJURY OR PROPERTY DAMAGE. THE  
QUALIFIED AGENCY PERFORMING THIS  
WORK ASSUMES RESPONSIBILITY FOR  
THIS CONVERSION.  
• 1 Burner Orifice (#38 NG, 1.55 mm LP)  
• 1 Pilot Orifice ( #30 for LP, #51 for NG)  
• Label A - to be completed and applied to the back  
of the fireplace.  
• Label B - apply to the fireplace Rating Plate as  
designated on the plate.  
WARNING: If appropriate, be sure to unplug the  
blower before proceeding with this conversion.  
IN CANADA:  
THE CONVERSION SHALL BE CARRIED  
OUT IN ACCORDANCE WITH THE REQUIRE-  
MENTS OF THE PROVINCIAL AUTHORITIES  
HAVING JURISDICTION AND IN ACCOR-  
DANCE WITH THE REQUIREMENTS OF THE  
CAN1-B149.1 AND .2 INSTALLATION CODE.  
Fuel Conversion Procedure  
1. Remove the Glass Frame:  
• Follow the removal procedure detailed on page 1.  
2. Empty the firebox:  
Lift and remove the Fettle and Logset package.  
CAUTION: THE LOGS ARE FRAGILE. Handle them  
with care and set aside out of the way.  
Cet equipement de conversion sera installe par une  
agence qualifiee de service conformement aux  
instructions du fabricant et toutes exigences et  
codes applicables de l’autorises avoir la juridiction.  
Si l’information dans cette Instruction n’est pas  
suivie exactement, un fey, explosion ou production  
de protoxyde de carbone peut resulter blessure  
personnelle de vie. L’agence qualifiee de service est  
esponsable de l’installation n’est pas propre et  
complete jusqu’a l’operation de l’appareil converti  
est cheque suivant les criteres etablis dans les  
instructions de proprietaire provisionnees avec  
l’equipement.  
Remove the Burner Skirt. Lift and tilt it to clear  
the firebox opening. See fig. 28.  
3. Change the Burner Orifice:  
• Loosen the locknut on the Air Shutter Stem,  
located under the firebox floor to the right of the  
Control Valve. Pull the stem forward as far as it  
will go. This will allow you to disengage the  
Burner Assembly. See fig. 29.  
• Lift the rear of the Burner Tube and rotate  
slightly forward. Slide the tube back enough to  
disengage it from the Air Shutter and Burner  
Orifice, then lift out. See fig. 30.  
• Slide the Air Shutter back out of the way to  
expose the orifice. See fig. 31. Using a ½” open  
end wrench or deep well socket remove the  
burner orifice and replace with the appropriate  
orifice, supplied in the kit.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Change the Pilot Orifice:  
FROM WITHIN THE FIREBOX, disengage the  
Pilot Hood by releasing the retainer clip as  
shown in fig. 32. Using the 4 mm hex key  
supplied, unscrew the pilot orifice (counter-  
clockwise). Replace with the appropriate  
orifice:  
#51 for Natural gas  
#30 for Propane  
Figure 28. Lift the Burner Skirt up and out of the firebox.  
Tighten new orifice into the base of the pilot  
assembly.  
• Replace Pilot Hood by pushing it into the  
base.  
Air Shutter  
Wingnut  
Pull Frame Spring  
Latch to release.  
Pilot Hood  
Pilot Orifice  
Retainer Clip  
Figure 29. Frame latch and air shutter stem location.  
PILOT ASSEMBLY  
Burner Tube  
Air  
Figure 32. Pilot Orifice replacement.  
Shutter  
Figure 30. Move shutter forward to disengage the  
burner tube assembly. .  
Burner Orifice  
Figure 31. Move air shutter back to access the  
burner orifice.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Replace the Burner Tube:. Slip the end of the tube  
into the Air Shutter and SLIDE TUBE FORWARD TO  
COMPLETELY COVER THE BURNER ORIFICE.  
6. Adjust the Air Shutter: See fig. 33.  
• Slide the shutter BACK to open the inlet, slide  
FORWARD to close. The standard settings are:  
Natural gas - 1/4” open  
Propane - 1/2” open  
• Tighten the wing nut on the Air Shutter Stem.  
• Replace the Burner Skirt.  
7. Change the Regulator: See fig. 34.  
Figure 33. Adjust Air Shutter as appropriate. Fully  
open position is shown here. Slide shutter forward to  
close.  
• Using a Torx T-20 screwdriver or small flat head  
screwdriver, remove the three specialty screws  
from the front of the valve regulator.  
• Remove the regulator tower and gasket.  
BE SURE TO REMOVE THE BLACK RUBBER GASKET  
FROM THE VALVE.  
• Install the new variable regulator tower with  
the new rubber gasket. Thoroughly tighten new  
regulator to valve body.  
Be sure to  
remove the black  
rubber gasket  
from the valve.  
8. Apply the Conversion Labels:  
Apply LABEL A to the cabinet floor so that it  
may be seen by anyone servicing the fireplace.  
• Apply LABEL B to the Rating Plate in the space  
provided.  
Apply small  
conversion notice  
label here.  
9. Reassemble the fireplace, apply gas to the system  
and check for gas leaks including all gas lines  
before and after the valve. NEVER USE AN OPEN  
FLAME TO CHECK FOR GAS LEAKS.  
IMPORTANT: Correct gas pressure is essential for  
efficient and safe operation. It is important that  
the correct gas pressure be established at the  
time of the installation. For more details, see the  
Gas Pressure section of this manual on page 12.  
Figure 34.  
Valve Regulator replacement.  
WHEN LIGHTING THIS APPLIANCE, ALWAYS REFER TO  
THE LIGHTING INSTRUCTIONS ON THE BACK COVER  
OF THIS MANUAL.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wall Thermostat Installation  
Remote Control  
Use Jøtul Thermostat #129706 or a 750 millivolt DC  
two-wire circuit thermostat to automatically control  
your fireplace operation. The thermostat should be  
placed in the same room as the heater, typically 5’  
off the floor. Avoid drafty areas or any area that  
may affect the accuracy of the thermostat.  
The optional Jøtul Remote Control can be installed  
on the Acadia gas fireplace. Using the wire sup-  
plied with the remote, connect the remote directly  
to the gas control valve. See fig. 36  
Connect one receiver lead to the terminal  
labelled TH. Connect the other receiver lead to the  
terminal labeled TH/TP. DO NOT DISCONNECT ANY  
OTHER WIRES FROM THE VALVE, AND DO NOT OVER  
TIGHTEN THE TERMINAL SCREWS.  
The thermostat should be connected to the  
Acadia using a minimum of 16 gauge wire with a  
maximum length of 35 feet of wire.  
Connect the two thermostat wire leads to the  
two lower terminals on the terminal block located  
to the right of the ON/OFF/T’STAT switch. Do not  
overtighten the connections. IT IS NOT NECESSARY  
TO DISCONNECT ANY OTHER WIRES. See Figure 34.  
Place the receiver unit under the control valve  
on the floor of the fireplace cabinet.  
At the thermostat, the two wires should be  
connected to the two connections screw on the  
thermostat base plate per the manufacturer’s  
instructions.  
CAUTION:  
LABEL ALL WIRES PRIOR TO DIS-  
CONNECTION WHEN SERVICING  
THE CONTROLS. WIRING ERRORS  
CAN CAUSE IMPROPER AND DAN-  
GEROUS OPERATION. ALWAYS  
VERIFY PROPER OPERATION AFTER  
SERVICING THE APPLIANCE.  
For thermostatic function, place the ON/OFF/T-  
STAT switch in the T-STAT position and the pilot  
flame must be lit.  
ATTENTION:  
AU MOMENT DE L’ENTRETIENDES  
COMMANDES, ETIQUETEZ TOUS LES  
FILS AVANT LE DEBRANCHEMENT.  
DES ERREURS DE CABLAGE  
PEUVENT ENTRAIUN  
ROCKER  
THERMOPILE  
SWITCH  
ON  
FONCTIONNEMENT INADEQUAT ET  
DAGEREUX.  
TH  
TP  
OFF  
STAT  
TH  
TP  
OPTIONAL  
THERMOSTAT  
or  
REMOTE  
CONTROL  
VALVE  
TERMINAL  
BLOCK  
Figure 36. ZG550 Acadia Wiring Diagram  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Brick Panel Assembly  
Install the optional Brick Panels before placing the  
Logset. Place the panels in position in the order as  
numbered in fig. 37. No fasteners or tools are  
required.  
Pull Frame Latches to  
Release Frame  
Upper Rear Panel,  
220031  
4
Left Side  
Panel,  
220997  
Right Side  
Panel,  
220996  
Figure 38. Glass Frame latch locations.  
1
2
3
Lower Rear Panel,  
220030  
Figure 37. Panel installation order.  
Side  
Panel  
1. Remove the Glass Frame, if you have not already  
done so. Open the lower control panel and locate  
the two frame latches under the firebox floor. See  
fig. 38  
. Pull the latch handle forward to  
disengage it from the bottom of the glass frame.  
You can then pull the frame out and up off of the  
three retainer tabs at the top of the firebox  
opening. Set the Glass Frame out of the way.  
Burner Skirt  
2. Remove the Fettle and Logset. These parts are not  
fastened. Simply lift them out of the firebox.  
3. Install the Side Panels. Set the bottom edge of  
each side panel on the Burner Skirt and against  
the firebox wall. Push the panel forward against  
the front lip of the firebox opening. See fig. 39.  
Figure 39. Install the Side Panels.  
4. Install the Lower Rear Panel. Orient the panel so  
that the beveled edge is on top and the mortar  
joints align with those on the side panels. Set the  
bottom edge on the shelf above the restrictor  
adjustment slots at the back of the firebox. The  
panel should fit snugly between the two side  
panels. See fig. 40.  
Bevelled Edge  
5. Install the Upper Rear Panel. This will also be a  
snug fit. Set the panel up high and then carefully  
lower it to seat its lower edge against the top of  
the other rear panel. The side panels will hold it in  
place.  
Figure 40. Install Lower Rear Panel.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Logset Assembly  
Unpack and arrange the five logs as outlined below.  
CAUTION: The logs are fragile. Handle with care.  
1
1. Seat Right Log (1) on the pin on the right side of  
3
the Burner Skirt. fig. 41.  
2
2. Set Rear Log (2) on the pins at the rear of the  
Burner Skirt. This log should overlap the back of  
the Right Log.  
3. Set the Left Log (3) on the pins at the left side of  
the Burner Skirt.  
4. Set the end of Front Log (4) into the pocket at  
the rear of Left Log (3). Engage the other end  
with the pin in the middle of the Burner Plate.  
Fig. 42.  
Figure 41. Install Right Log, Rear Log and Left Log in  
that order.  
5. Engage the upper end of the Cross-over Log (5)  
with the pin in the Rear Log. Fig. 42. Set the  
Cross-over Log across the top of the lower end of  
the Front Log (4) as illustrated.  
6. Spread a layer of ember stones evenly over the  
surface of the Burner Plate. Allow for 1/4”  
clearance between the stones and the inner  
edge of the Burner Skirt. Avoid blocking the pilot  
flame area with ember stones. See Fig. 43.  
5
7. Replace the Glass Panel Frame: Engage the top  
of the frame with the three tabs at the top of  
the firebox. Push the bottom of the frame  
against the firebox face and pull the Frame  
Latches out to engage them with the slots in the  
bottom of the frame.  
4
Figure 42. Install Front and Cross-over logs as shown.  
Pilot  
Area  
Figure 43. Install ember stones, keeping clearance  
around the pilot crossover area.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Surround Assembly  
1. Install the Lower Grill / Control Door.  
• Secure the hinges to the cabinet frame using  
the hex head screws provided in the hardware  
bag. fig. 44.  
2. Install each of the Side castings onto the  
cabinet by engaging the hanger tabs with the  
holes in the cabinet frame. See fig. 52 for  
orientation.  
3. Install the Right and Left Upper Grill plates.  
Figure 44. Install the Lower Grill / Control Door.  
4. Attach the Inner Panel to the Center Plate. The Inner  
Panel may be reversed to show the winter scene.  
(Note: Blue Black Panel is enamelled on one side only).  
5. Hang the Center Plate in position.  
Optional Double Door  
The Double Door set is fully assembled and requires  
no tools for installation. Use the 4 mm hex key  
supplied with the doors to adjust the door alignment  
at the eight socket head hinge screws.  
Door Installation  
Unpack the door set and inspect the parts for  
damage. Notify your dealer if any damage is found.  
Figure 45. Hang the frame on the cabinet.  
You may wish to remove the doors from the  
frame to lighten the assembly and ease installation.  
They simply lift off of the hinges.  
B
The door assembly attaches to the fireplace by  
engaging the three slots in the upper frame with the  
corresponding steel tabs at the top of the firebox.  
See fig. 45.  
B
A dimple located on the inside of the frame at  
each lower corner engages with corresponding holes  
in the glass frame to hold the bottom of the door  
assembly securely to the firebox. See A, fig. 46.  
A
A
Figure 46. Rear view of door frame.  
1. Open the Control Access Door. Hang the door  
frame onto the firebox by engaging the tabs with  
the holes in the frames. See fig. 45.  
2. Push the frame over to one side and engage the  
dimple on that lower corner with the hole in the  
side of the glass frame. You will feel it lock into  
place.  
Loosen  
screws to  
adjust  
3. Push the frame assembly over to the opposite side  
and push that lower corner down to engage with  
the firebox.  
door  
alignment  
Door Alignment Adjustment  
You can adjust the door alignment if necessary by  
loosening the hinge screws (See B, fig. 46 and fig.  
Figure 47. Door adjustment points.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Check  
1. PURGING THE GAS LINE: When lighting the  
appliance for the first time it will take a few  
moments to clear the gas line of air. Once this  
purge is complete, the appliance will operate as  
described in the lighting instructions located on  
the fireplace’s rating plate and back cover of this  
manual.  
Flame Appearance / Air Shutter  
Adjustment  
THE ACADIA GAS FIREPLACE IS SHIPPED FROM THE  
FACTORY EQUIPPED TO USE NATURAL GAS. IF THE  
BURNER HAS BEEN CONVERTED FOR USE WITH  
PROPANE, IT WILL BE NECESSARY TO ADJUST THE AIR  
SHUTTER ON THE BURNER TUBE TO ACHIEVE THE  
PROPER GAS TO AIR MIX. See Figure 26.  
2. PILOT FLAME: The pilot flame should be steady,  
not lifting or floating. The flame should be blue  
in color around the pilot hood, with traces of  
yellow toward the outer edges. It is imperative  
that the pilot flame engulf the top 3/8” of the  
thermopile (power generator) and the top 1/8” of  
the quick drop out thermocouple. The pilot flame  
should project out of the pilot hood 1” at all three  
ports. See Figure 48.  
WARNING:  
AIR SHUTTER ADJUSTMENTS SHOULD ONLY  
BE PERFORMED BY A QUALIFIED PROFES-  
SIONAL SERVICE TECHNICIAN.  
The air shutter adjustment can also help achieve the  
desired flame appearance. Generally, flame appear-  
ance is a matter of individual preference, however a  
warm yellowish flame is most common. See fig. 49.  
3. BURNER ADJUSTMENT: Your Jøtul GZ550 Acadia  
gas fireplace is equipped with a variable gas  
control valve. This valve provides easy adjust-  
ment of the flame height appearance and heat  
output. To adjust the flame between the HI and  
LO setting, rotate the HI/LO knob, located in the  
center of the valve face. Flame height will adjust  
approximately 1.0” to 1.5” between the HI and LO  
settings.  
Closing the air shutter - will generate very long  
yellow flames resulting in soot. Sooting produces  
black deposits on the logs, on the inside walls of  
the appliance, and potentially on the exterior  
termination cap.  
Sooting is caused by incomplete combustion in  
the flames and lack of combustion air entering  
the air shutter opening.  
NO SMOKE OR SOOT SHOULD BE PRESENT. CHECK  
LOG PLACEMENT IF ANY SOOT OR SMOKE IS DE-  
TECTED. IF SOOT OR SMOKE PERSISTS, THE AIR  
SHUTTER MAY NEED TO BE ADJUSTED.  
Opening the air shutter - will generate a flame that is  
blue and transparent, or an “anemic” flame. This  
flame is generally more efficient but not as pretty.  
CAUTION:  
Pilot Hood  
Ignitor  
DO NOT ATTEMPT TO ALTER THE FLAME  
APPEARANCE BY POSITIONING THE GAS  
VALVE IN ANY OTHER POSITION OTHER  
THAN THE FULL “ON” POSITION.  
1”  
(25mm)  
3/8”  
(8mm)  
Min.  
1/8”  
(3mm)  
Min.  
Thermopile  
Thermocouple  
Figure 48 Correct Pilot Flame Pattern  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Air Shutter Adjustment Stem  
Air Shutter Adjustment  
1. Open the Lower Grill panel and locate the Air  
Shutter adjustment stem extending down from  
the right side of the firebox floor. See figs. 49.  
2. Loosen the locknut and push the stem BACK (to  
the rear of the firebox) to open the air inlet  
increasing airflow into the burner. Push the stem  
FORWARD to decrease the air inlet. Make adjust-  
ments in 1/8” (3 mm) increments and allow time  
for flame pattern to respond to the new setting.  
Retighten the locknut when the desired flame  
pattern is established.  
3. Reassemble the fireplace including glass assem-  
bly. Allow the fireplace to burn 15 -20 minutes on  
the HIGH setting, observing the flame continu-  
ously.  
Figure 49. Air Shutter adjustment location.  
4. If the flame appears weak, slow, or sooty, repeat  
the process described above until the flame is as  
desired.  
Air Inlet Settings  
Natural Gas - 1/4” open  
Propane - 1/2” open  
IMPORTANT: Run the fireplace for a minimum  
of 15 to 20 minutes to produce an accurate  
representation of the flame appearance. This  
warm-up should be done before and between  
any air shutter adjustment.  
Figure 50. Proper flame pattern.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
1. Your Acadia gas fireplace can be operated manu-  
ally using the On/Off/T-stat rocker switch or it can  
be automatically controlled using an optional  
wall-mounted thermostat and/or remote control  
device. A separate switch is provided for the  
optional forced air blower kit.  
Pilot Assembly  
Familiarize yourself with the location and func-  
tion of the controls. See Figs. 51 and 52.  
Gas Control - Used to control the Pilot light and  
gas flow from the supply line.  
Regulator - Allows you to adjust heat output and  
flame intensity.  
Piezo Ignitor - Push button pilot light ignition.  
Figure 51. The pilot assembly is located at the right  
rear corner of the burner plate under the right log.  
ON/OFF/ T’STAT Switch - Allows for manual or  
thermostatic control of the burner.  
Always follow the Lighting Instructions located  
on the inside Back Cover of this manual.  
2. For the first several hours of operation, it is  
common that you will detect some odor as the  
metal and manufacturing materials cure under  
heat. This condition is temporary and can be  
alleviated by allowing plenty of fresh air to  
circulate through the area.  
Gas Control  
Knob  
Regulator  
3. Condensation may develop on the glass upon  
each lighting of the appliance. This “fog” will  
disappear as the glass heats.  
BURNER  
IGNITOR  
ON  
OFF  
TSTAT  
4. Keep the controls and the area under the appli-  
ance free of debris; vacuum this area frequently.  
Always keep the appliance area clear and free  
from combustible materials, gasoline and other  
flammable liquids.  
HI  
LO  
On/Off/T’stat Switch  
Piezo Ignitor  
When a vacuum is used on any service for the  
fireplace, ALWAYS be sure the fireplace is com-  
pletely cold.  
Figure 52. Burner Controls.  
5. Remember, your fireplace utilizes a continuously  
burning pilot flame. Exercise caution when using  
household products containing combustible  
vapors.  
6. CAUTION: DO NOT OPERATE THIS APPLIANCE  
WITH THE GLASS REMOVED, CRACKED OR BRO-  
KEN. REPLACEMENT OF THE GLASS SHOULD BE  
DONE BY A LICENSED OR QUALIFIED SERVICE  
PERSON. USE ONLY REPLACEMENT GLASS PRO-  
VIDED BY YOUR AUTHORIZED JØTUL DEALER.  
NEVER USE ANY SUBSTITUTE MATERIALS.  
WARNING:  
OBSERVE CAUTION NEAR THE GLASS  
PANEL. THE GLASS MAY SHATTER  
WHEN STRUCK BY AN OBJECT. ALWAYS  
HANDLE THE GLASS PANEL WITH CARE.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Maintenance  
The Acadia gas fireplace and its venting system  
should be inspected before use and at least annually  
by a qualified service technician.  
Glass Panel or Gasket Removal  
1. Open the Lower Grill Panel.  
2. Release the glass clips at either side of the bottom  
of the firebox.  
IMPORTANT:  
3. Swing the bottom of the glass frame out and lift  
to disengage it from the three retainer tabs at the  
top of the firebox.  
ALWAYS TURN OFF THE GAS SUPPLY TO  
THE FIREPLACE AND UNPLUG THE  
FORCED AIR BLOWER BEFORE ANY SER-  
VICE WORK IS PERFORMED ON THE FIRE-  
PLACE.  
4. Lay the assembly on a flat surface and carefully lift  
the metal tabs that secure the glass panel to the  
frame. Remove the old gasket material.  
5. Install the new glass panel and gasket in the glass  
frame and secure with metal tabs. Do not over  
tighten tabs as that may damage the glass.  
General Cleaning  
The firebox should be vacuumed annually to remove  
any surface build up. Use a soft brush attachment  
and handle the logs carefully as they are fragile. Be  
sure to vacuum or wipe off the pilot assembly and  
burner orifice and burner tube.  
ONLY USE JØTUL AUTHORIZED PARTS. NEVER SUBSTI-  
TUTE NON-JØTUL PARTS ON THIS FIREPLACE.  
Glass Care  
Clean the glass only when necessary. Wipe the  
surface with a clean, dampened, soft cloth. Follow  
with a dry, soft towel. Take care not to scratch the  
glass surface.  
WARNING:  
DO NOT USE ABRASIVE CLEANERS ON  
THE GLASS. NEVER CLEAN THE GLASS  
WHEN IT IS HOT.  
Gasket Inspection  
It is important that the glass gasket be inspected at  
least annually. Examine the ribbon gasket for signs  
of deterioration and make sure the gasket has a  
positive seal. Replace the gasket if necessary. Refer  
to the replacement parts list on page 28.  
Figure 53. Replacing the glass gasket.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RETAIN THIS MANUAL FOR REFERENCE AND  
MAKE IT AVAILABLE TO ANYONE USING OR SERVIC-  
ING THE FIREPLACE.  
SERVICE LOG:  
First Year  
Name of Technician________________________  
Company Name____________________________  
Date of service_____________________________  
MODEL NAME: GZ 550 DV Acadia Gas Fire-  
place  
SERIAL NUMBER:__________________________  
DATE OF PURCHASE:_______________________  
AUTHORIZED DEALER:_____________________  
NAME OF INSTALLER:______________________  
TYPE OF FUEL:_____________________________  
Work Per-  
formed____________________________  
____________________________________________  
____________________________________________  
WAS FIREPLACE CON-  
VERTED?__________________  
SERVICE LOG:  
Second Year  
NOTES:  
Name of Technician________________________  
Company Name____________________________  
Date of service_____________________________  
Work Per-  
formed____________________________  
____________________________________________  
____________________________________________  
BLOWER  
SERVICE LOG:  
Third Year  
G
BLU  
BK  
YEL  
W
G
Name of Technician________________________  
Company Name____________________________  
Date of service_____________________________  
BLU  
TERM  
BK  
SNAP STAT  
BK  
RHEOSTAT  
POWER  
SUPPLY  
BRN  
BLU  
GRY  
BLU  
Work Per-  
formed____________________________  
SWITCH  
____________________________________________  
____________________________________________  
MANUAL OFF AUTO  
Figure 54. ZG550 DV Acadia Blower Wiring Diagram  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GZ 550 DV Acadia Parts  
71.  
72.  
Surround Leg, Right / Matte Black  
Surround Leg, Right / Blue Black  
Surround Leg, Right / Jøtul Iron  
Surround Leg, Left / Matte Black  
Surround Leg, Left / Blue Black  
Surround Leg,Left / Jøtul Iron  
Hang Tab  
10395792  
10395727  
10395785  
10395992  
10395927  
10395985  
129680  
11730  
No.  
1.  
2
Description  
Screw, #8 x 1/2 Sheet metal  
Adaptor, 8”  
Part Number  
117917  
129784  
129775  
9930  
3.  
4.  
Gasket, 8” Adaptor  
M6 Hex Nut  
73.  
74.  
75.  
5.  
Adaptor, 5”  
129782  
129774  
220952  
129774  
220955  
117917  
220964  
117917  
220961  
220969  
220011  
117917  
117917  
220959  
117946  
129159  
220913  
220957  
129773  
220963  
220049  
9930  
M6 x 12 Hex Bolt  
6.  
7.  
8.  
9.  
Gasket, 5” Adaptor  
Air Intake Manifold  
Gasket, 5” Adaptor  
Top Shroud, Level 1  
Screw, #8 X 1/2” Sheet metal  
Support Bracket  
Surround Breastplate, Right / Matte Black  
Surround Breastplate, Right / Blue Black  
Surround Breastplate, Right / Jøtul Iron  
Surround Keystone / Matte Black  
Surround Keystone / Blue Black  
Surround Keystone / Jøtul Iron  
Tablet / Matte Black  
10395692  
10395627  
10395685  
10395592  
10395527  
10395585  
10396692  
10396627  
10396685  
10395492  
10395427  
10395485  
129471  
220546  
129670  
220790  
129668  
220520  
220044  
155831  
155830  
117117  
155612  
155612  
117975  
155612  
220987  
155612  
220783  
155612  
220954  
155612  
9930  
129390  
117917  
117975  
220388  
129464  
129463  
220395  
129152  
129130  
220048  
129673  
220950  
129760  
117917  
220004  
117917  
129772  
129759  
220956  
117917  
220009  
117917  
220962  
220947  
117917  
220789  
117917  
117986  
221102  
220702  
129766  
129765  
3094527  
76.  
77.  
78.  
10.  
11.  
12.  
13.  
14.  
15.  
16.  
17.  
18.  
19.  
20.  
21.  
22.  
23.  
24.  
25.  
26.  
27.  
28.  
29.  
30.  
31.  
32.  
33.  
34.  
35.  
36.  
37.  
38.  
39.  
40.  
41.  
42.  
43.  
44.  
45.  
46.  
47.  
48.  
49.  
50.  
51.  
52.  
53.  
54.  
Screw, #8 x 1/2 Sheet metal  
Cabinet Wall, Rear  
Stand-ott, 1” Framing  
Wallstud Brace  
Screw, #8 x 1/2 Sheet metal  
Screw, #8 x 1/2 Sheet metal  
Cabinet Wall, Left  
Rivet, .125 x .250  
Lanyard, 062 Wire (Rating Plate)  
Rating Plate  
Cool Air Channel  
Air Intake Gasket  
Air Intake Restrictor Plate  
Latch Assembly  
Tablet / Blue Black  
Tablet / Jøtul Iron  
Surround Breastplate, Left / Matte Black  
Surround Breastplate, Left / Blue Black  
Surround Breastplate, Left/ Jøtul Iron  
Pilot Assembly - NG  
Spacer, Pilot Assembly  
Gasket, Pilot Assembly  
Primary Air Shutter Assembly  
Orifice Holder  
Gas Valve - NG (50% TD)  
Compression Nipple, 3/8 NTP - 5/16  
Rheostat Assembly  
Wire Harness Assembly  
M6 x 20 Hex Bolt  
Tube Holder, Cast Iron  
Venturi Tube  
M6 Wingnut  
M6 AS Series Fastener  
Gasket, Air Intake Restrictor  
Burner Base, Cast Iron  
Subfloor - Burner Skirt  
Gasket, Burner  
Exhaust Baffle  
Burner Plate Assembly  
M6 Hex Nut  
Flex Tube, 5/16” x 14”  
#8 x 1/2” Sheet metal Screw  
M6 Wingnut  
Cover Plate, Primary Air Restrictor  
Compression Nut - 5/16  
Compression Sleeve - 5/16  
Gasket, Cover Plate  
Jam Nut  
Orifice, #38 - NG  
Orifice, 1.55 - LP  
Gasket, Heat Exchanger  
Heat Exchanger  
79.  
80.  
81.  
82.  
83.  
84.  
85.  
86.  
87.  
88.  
89.  
90.  
91.  
92.  
93.  
94.  
M6 Hex Nut  
M6 Hex Nut  
M6 Wingnut  
9930  
117975  
117967  
117130  
220958  
117911  
220945  
220930  
117922  
129154  
129679  
117920  
3902573  
117921  
129729  
129730  
220717  
220709  
220703  
220944  
117922  
12979392  
117921  
901043  
117970  
220574  
117917  
10395892  
10395827  
10395885  
117970  
154987  
129124  
220042  
129757  
220957  
220960  
11039627  
10396727  
129680  
11730  
M6 x 12 Flat Head Phillips Screw  
M6 x 12 Hex Bolt  
Cabinet Base  
10-32 x 3/8 Phillips Screw  
Valve Bracket  
Terminal Block Bracket  
M4 Hex Nut  
Terminal Block, 2 Pole  
Igniter Bracket  
M4 x 8 Phillips Screw  
Ignitor  
M4 x 12 Phillips Screw  
Knob Extension, On/Off  
Knob Extension, Hi/Lo  
Rheostat Nut  
Knob, Rheostat Control  
On / Off Switch  
Controls Board  
M4 Hex Nut  
Hinge Adaptor  
M4 x 10 Hex Bolt  
Control Door Hinge  
M5 x 10 Screw  
Lanyard, .062 Wire - Control Door  
Screw, #8 x 1/2 Sheet metal  
Control Door - Matte Black  
Control Door - Blue Black  
Control Door - Jøtul Iron Gray  
M5 x 10 Screw  
Ceramic Glass, Replacement (inc. gasket)  
Gasket, Glass Tadpole  
Glass Clip, Tinnerman  
Glass Frame  
95.  
96.  
97.  
98.  
99.  
100.  
101.  
102.  
103.  
104.  
105.  
106.  
107.  
108.  
109.  
110.  
111.  
112.  
113.  
114.  
115.  
116.  
117.  
118.  
119.  
120.  
121.  
122.  
123.  
124.  
125.  
126.  
127.  
128.  
129.  
130.  
131.  
Glass Frame Hanger  
#8 x 1/2” Sheet metal Screw  
Relief Door Guide  
#8 x 1/2” Sheet Metal Screw  
Gasket, Relief Door  
Relief Door  
55.  
56.  
57.  
58.  
59.  
60.  
61.  
62.  
63.  
64.  
65.  
66.  
67.  
68.  
69.  
70.  
Top Shroud, Level 2  
#8 x 1/2” Sheet Metal Screw  
Keystone Heat Shield  
#8 x 1/2” Sheet Metal Screw  
Cabinet Top  
Firebox  
#8 x 1/2” Sheet Metal Screw  
Sheetrock Standoff  
#8 x 1/2” Sheet Metal Screw  
#8 x 3/4” Sheet Metal Screw  
Air Deflector, Burner Skirt  
Ember Stones, 4 oz. *  
Thermocouple *  
Cool Air Channel  
Cabinet Wall, Right  
Fettle, Blue Black Enamel  
Andiron, Blue Black Enamel  
Hang Tab  
M6 x 12 Hex Bolt  
Log, Left  
Log, Front  
Log, Cross-over  
Log, Right  
Log, Rear  
220993  
220995  
220701  
220994  
220992  
Electrode *  
Thermopile *  
* not illustrated  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GZ 550 DV Optional Accessories  
• Antique Brick Kit ............................................ 155805  
• Two Speed Blower, 125 / 60 c.f.m. ............ 155630  
• 4” x 6-5/8” Adaptor Kit ................................ 154974  
• High Altitude Conversion Kit - NG ........... 155610  
• High Altitude Conversion Kit - LP ............. 155611  
• Fuel Conversion Kit - LP................................ 155594  
• Fuel Conversion Kit - NG.............................. 155595  
• Wall Thermostat ............................................ 750003  
• Remote Control .............................................. 129706  
QuickFace Fronts w/ Screen  
Steel Rectangular, Matte Black.................. 154964  
Steel Arch, Matte Black ................................ 154965  
Brushed Stainless Steel, Rectangular ...... 154968  
Brushed Stainless Steel Arch...................... 154969  
• Arched Double Doors, Matte Black .......... 350560  
• Arched Double Doors, Blue Black.............. 350561  
• Double Door Basket Screen ........................ 154973  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LIGHTING INSTRUCTIONS  
FOR YOUR SAFETY, READ BEFORE LIGHTING.  
WARNING:  
IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY  
RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE.  
• If your gas supplier cannot be reached, call the  
fire department.  
A. This appliance has a pilot which must be lit  
by hand. When lighting the pilot, follow  
these instructions exactly.  
C. Use only your hand to push in or turn the gas  
control knob. Never use tools. If the knob will  
not push in or turn by hand, do not try to repair  
it. Call a qualified technician. Force or attempted  
repair may result in a fire or explosion.  
B. BEFORE LIGHTING, smell all around the  
appliance area for gas. Be sure to smell next  
to the floor because some gas is heavier than  
air and will settle to the floor.  
D. Do not use this appliance if any part has been  
under water. Immediately call a qualified service  
technician to inspect the appliance and to  
replace any part of the control system and any  
gas control which has been under water.  
WHAT TO DO IF YOU SMELL GAS:  
• Extinguish any open flame.  
• Open windows.  
• Do not light any appliance.  
• Do not touch any electrical switches.  
• Do not use any phone in your building.  
• Immediately call your gas supplier from a  
neighbor’s phone.  
LIGHTING INSTRUCTIONS  
1. STOP! Read the safety information above.  
7. Push in gas control knob slightly and turn counter-  
clockwise toPILOT”.  
2. Access the lower controls.  
8. Push in control knob all the way and hold in.  
Immediately light the pilot by triggering the spark  
ignitor (push the red button repeatedly) until pilot  
lights. Continue to hold the control knob in for  
about one minute after  
3. Turn the stove ON/OFF switch toOFF”, or set the  
thermostat to lowest setting (if used).  
4. Confirm that the gas supply line shut-off valve is open.  
the pilot lights. Release  
knob and it should  
spring back. The pilot  
Control  
Knob  
should remain lit. If it  
goes out, repeat Steps 5  
through 8.  
• If knob does not  
return when released,  
Pilot Assembly  
Control Valve  
stop and immediately call your service technician  
or gas supplier.  
5. Push in gas control knob slightly and turn clockwise  
toOFF”.  
• If pilot will not stay lit after several tries, turn  
the control knob to OFF and call your service  
technician or gas supplier.  
NOTE: Knob cannot be turned fromPILOTtoOFF”  
unless the knob is pushed in slightly. Do not force.  
6. Wait five (5) minutes to clear out any gas. If you then  
smell gas, STOP! FollowBin the safety information  
above on this page. If you do not smell gas, go to the  
next step.  
9. Turn gas control knob counterclockwise  
toON”.  
10.Turn the stove ON/OFF switch toON”, or set  
thermostat (if used) to desired temperature.  
TO TURN OFF GAS TO THE APPLIANCE:  
1. Turn ON/OFF switch toOFF”. The pilot will remain lit for  
3. Access the lower controls.  
4. Depress gas control knob slightly and turn clock-  
wise toOFF”. Do not force.  
normal service.  
2. For complete shutdown, turn ON/OFF switch toOFF”.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
This appliance must be installed in conformance with local and national building regulations. Before  
beginning the installation, it is important that the these instructions be carefully read and understood.  
Jøtul maintains a policy of continual product development. Consequently, products may differ in  
specification, color or type of accessories from those illustrated or described in various publications.  
Jøtul vise sans cesse a ameliorer ses produits. C’est pourquoi, il se reserve le droit de modifier les  
specifications, couleurs etequipement sans avis prelable.  
Jøtul ASA  
P.O. Box 1411  
N-1602 Fredrikstad  
Norway  
Jøtul North America  
400 Riverside Street  
Portland, ME 04104  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Ingersoll Rand Oven 49999 521 User Manual
Invacare Camping Equipment BariatricBed User Manual
Jenn Air Microwave Oven JMW2327W User Manual
Jensen Car Stereo System JHD1120 User Manual
JVC Computer Monitor TM A14E User Manual
JVC Security Camera TK C2201UA User Manual
Jwin MP3 Player JX CD561 User Manual
Kenwood CD Player D R350 User Manual
Klark Teknik Stereo Equalizer DN3600 User Manual
Kodak Camera Accessories Aptus II User Manual