Johnson Controls Air Conditioner GCGD18 thru 60 User Manual

TABULAR DATA SHEET  
Outdoor Split System Air Conditioner 1.5 Thru 5 Tons  
MODELS: GCGD18* THRU 60  
13 SEER – R-22 – 1 PHASE  
Physical and Electrical Data  
GCGD18S  
21S2X(E)  
GCGD24S  
21S2X(E)  
GCGD30S  
21S2(E)  
GCGD36S  
21S2(E)  
GCGD42S  
21S2(E)  
GCGD48S  
21S2(E)  
GCGD60S  
21S2(E)  
MODEL  
Unit Supply Voltage  
208-230V, 1 60Hz  
Normal Voltage Range 1  
Minimum Circuit Ampacity  
187 to 252  
18.2  
8.5  
15  
13.2  
20  
14.0  
20  
19.9  
30  
22.7  
35  
33.5  
50  
Max. Overcurrent Device Amps 2  
30  
Min. Overcurrent Device Amps 3  
Compressor Type  
15  
Recip  
6.4  
15  
Recip  
9.9  
54  
15  
Recip  
10.6  
61  
20  
25  
Recip  
14.7  
78  
25  
Recip  
17.0  
86  
35  
Scroll  
25.6  
150  
No  
Recip  
Rated Load  
Compressor Amps  
13.4  
Locked Rotor  
36  
78  
Crankcase Heater  
No  
No  
No  
No  
No  
No  
Factory External Discharge Muffler  
Factory External Check Valve  
No  
No  
Yes  
No  
Yes  
Yes  
No  
Yes  
No  
No  
No  
No  
No  
No  
HS Kit Required with TXV 4  
Yes  
0.5  
Yes  
0.8  
18  
Yes  
0.80  
18  
Yes  
Yes  
1.5  
Yes  
1.5  
No  
Fan Motor Amps  
Fan Diameter Inches  
Rated HP  
Rated Load  
1.4  
1.5  
18  
18  
22  
22  
22  
1/12  
1100  
1550  
9.60  
1
1/8  
1075  
1850  
9.60  
1
1/8  
1/4  
1/4  
1/4  
1/4  
Fan Motor  
Nominal RPM  
Nominal CFM  
Face Area Sq. Ft.  
Rows Deep  
1075  
1950  
11.30  
1
1100  
850  
3000  
16.50  
1
850  
3000  
16.50  
1
850  
3300  
19.75  
1
2400  
12.10  
Coil  
1
Fin / Inches  
23  
23  
23  
23  
23  
23  
23  
Liquid Line Set OD (Field Installed)  
Vapor Line Set OD (Field Installed)  
3/8  
3/8  
3/4  
3/8  
3/8  
3/8  
3/8  
3/8  
5/8  
3/4  
3/4  
See Note 5 Below  
0.68  
7/8  
7/8  
1-1/8  
Unit Charge (Lbs. - Oz.) 5  
Charge Per Foot, Oz.  
Operating Weight Lbs.  
0.66  
130  
0.68  
130  
0.68  
150  
0.70  
175  
0.70  
176  
0.76  
200  
160  
Models with “E” on the end of the model number have an ElectroFin® coating on the outdoor coil.  
1. Rated in accordance with AHRI Standard 110-2012, utilization range “A”.  
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.  
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.  
4. See Hard Start Kit Accessory Installation Manual for Hard Start Kit part number for each model.  
5. Units have been shipped without refrigerant. Remove nitrogen holding charge, evacuate, and charge to the system charge listed on the second page of the data  
sheet. System charges listed include 15 feet of lineset.  
All dimensions are in inches. They are subject to change without notice.  
Certified dimensions will be provided upon request.  
C
.
Dimensions  
(Inches)  
Refrigerant Connection  
Service Valve Size  
Unit  
Model  
A1  
28  
28  
32  
34  
34  
34  
40  
B
C
Liquid  
Vapor  
23-1/2 23-1/2  
23-1/2 23-1/2  
23-1/2 23-1/2  
23-1/2 23-1/2  
18  
24  
30  
36  
42  
48  
60  
3/4”  
A
3/8”  
29  
29  
29  
29  
29  
29  
7/8”  
7/8”2  
B
1. Overall height from bottom of base pan to top of fan guard.  
2. Adapter fitting required for 1-1/8” line set.  
Johnson Controls Unitary Products  
833101-UTD-B-0612  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Indesit Washer WG1030G User Manual
Insignia Home Theater System NS H4005 User Manual
JBL Car Speaker CS2165C User Manual
Kenmore Gas Grill 1461613211 User Manual
Kensington Fax Machine 62405 User Manual
Kenwood Automobile Parts KDC 208U User Manual
Kenwood Two Way Radio TH G71A User Manual
Kettler Bicycle KT499 200 User Manual
KitchenAid Clothes Dryer KEYS977E User Manual
Kodak Scanner 9E8651 User Manual