INSTALLATION INSTRUCTIONS
ELECTRIC DOWNDRAFT SLIDE-IN RANGES
INSTRUCTIONS D’INSTALLATION
DES CUISINIÈRES ÉLECTRIQUE À ÉVACUATION
DESCENDANTE ENCASTRABLE
Table of Contents/Table des matières
RANGE SAFETY .............................................................................2
SÉCURITÉ DE LA CUISINIÈRE ...................................................23
INSTALLATION REQUIREMENTS................................................3
Tools and Parts ............................................................................3
Location Requirements................................................................3
Venting Requirements..................................................................5
Venting Methods..........................................................................5
Calculating Vent System Length..................................................6
Electrical Requirements - U.S.A. Only.........................................7
Electrical Requirements - Canada Only.......................................8
Countertop Preparation ...............................................................8
INSTALLATION INSTRUCTIONS..................................................9
Unpack Range..............................................................................9
Adjust Leveling Legs....................................................................9
Install Anti-Tip Bracket.................................................................9
Install Downdraft System...........................................................10
Electrical Connection - U.S.A. Only...........................................14
Connect Range to Downdraft System.......................................19
Complete Installation .................................................................21
Moving the Range......................................................................21
EXIGENCES D’INSTALLATION...................................................24
Outils et pièces...........................................................................24
Exigences d’emplacement.........................................................24
Exigences concernant l’évacuation ...........................................26
Méthodes d’évacuation..............................................................27
Calcul de la longueur effective du circuit d’évacuation.............28
Spécifications électriques ..........................................................29
Préparation du plan de travail....................................................29
INSTRUCTIONS D’INSTALLATION.............................................30
Déballage de la cuisinière ..........................................................30
Réglage des pieds de nivellement.............................................30
Installation de la bride antibasculement ....................................31
Installation du circuit d’évacuation par le bas ...........................31
Raccordement de la cuisinière au circuit d’évacuation
par le bas....................................................................................35
Achever l’installation ..................................................................37
Déplacement de la cuisinière.....................................................38
IMPORTANT:
Save for local electrical inspector's use.
IMPORTANT :
À conserver pour consultation par l'inspecteur local des installations électriques.
W10253462A
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION REQUIREMENTS
If using a power supply cord:
■
A UL listed power supply cord kit marked for use with ranges.
Tools and Parts
The cord should be rated at 250 volts minimum, 40 amps or
50 amps that is marked for use with nominal 1³⁄₈" (3.5 cm)
diameter connection opening and must end in ring terminals
or open-end spade terminals with upturned ends.
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
■
A UL listed strain relief.
■
■
■
■
■
■
Tape measure
■
■
■
■
■
■
Wrench or pliers
⁵⁄₁₆" nut driver
¼" nut driver
Drill
Check local codes. Check existing electrical supply. See
“Electrical Requirements” section.
Level
It is recommended that all electrical connections be made by a
licensed, qualified electrical installer.
Phillips screwdriver
Flat-blade screwdriver
Saber or keyhole saw
Marker or pencil
¹⁄₈" (3.2 mm) drill bit
Location Requirements
³⁄₁₆" (4.8 mm) carbide-tipped
masonry drill bit (for concrete/
ceramic floors)
IMPORTANT: Observe all governing codes and ordinances.
■
It is the installer’s responsibility to comply with installation
clearances specified on the model/serial rating plate. The
model/serial rating plate is located on the right-hand side of
the oven frame behind the storage drawer panel.
Parts supplied
Check that all parts are included.
■
■
The range should be located for convenient use in the
kitchen.
■
■
■
■
■
■
■
■
■
■
■
3 - #10-32 hex nuts (attached to terminal block)
3 - Terminal lugs
To eliminate the risk of burns or fire by reaching over heated
surface units, cabinet storage space located above the
surface units should be avoided. If cabinet storage is to be
provided, the risk can be reduced by installing a range hood
that projects horizontally a minimum of 5" (12.7 cm) beyond
the bottom of the cabinets.
2 or 3 - Oven racks (depending on your model)
Blower motor
2 - vent clamps
Flexible vent
■
■
Cabinet opening dimensions that are shown must be used.
Given dimensions are minimum clearances.
Flow tester card
Blower location template
The floor anti-tip bracket must be installed. To install the anti-
tip bracket shipped with the range, see “Install Anti-Tip
Bracket” section.
4 - #8 x ¾" screws (for mounting blower motor bracket)
2 - #12 x 1⁵⁄₈" screws (for mounting anti-tip bracket)
■
Grounded electrical supply is required. See “Electrical
Requirements” section.
Anti-tip bracket (taped to package containing literature in
oven cavity)
IMPORTANT: To avoid damage to your cabinets, check with your
builder or cabinet supplier to make sure that the materials used
will not discolor, delaminate or sustain other damage. This oven
has been designed in accordance with the requirements of UL
and CSA International and complies with the maximum allowable
wood cabinet temperatures of 194°F (90°C).
Anti-tip bracket must be securely mounted to back wall or
floor. Thickness of floor may require longer screws to anchor
bracket to subfloor. Longer screws are available from your
local hardware store.
Parts needed
■
One of the following Jenn-Air wall caps:
Jenn-Air® 5" (12.7 cm) Round Surface Wall Cap Damper.
Order Part Number A405.
Jenn-Air® 6" (15.2 cm) Round Surface Wall Cap Damper.
Order Part Number A406.
Jenn-Air® 3¼" x 10" (8.3 x 25.4 cm) Surface Wall Cap
Damper. Order Part Number A403.
Mobile Home - Additional Installation Requirements
The installation of this range must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280). When such standard is not
applicable, the Standard for Manufactured Home Installations,
ANSI A225.1/NFPA 501A or with local codes.
Mobile home installations require:
To order, see the “Assistance or Service” section of the Use
and Care Guide.
■
When this range is installed in a mobile home, it must be
secured to the floor during transit. Any method of securing
the range is adequate as long as it conforms to the standards
listed above.
■
■
■
■
Metal ducting
Vent clamps
■
Four-wire power supply cord or cable must be used in a
mobile home installation. The appliance wiring will need to be
revised. See “Electrical Connection” section.
Concrete anchors (for concrete floor mounting)
2 - 2" x 4" x 8¾" (5.0 x 10.2 x 22.2 cm) wood spacers (for left
or right side venting)
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Product Dimensions
Cabinet Dimensions
Cabinet opening dimensions shown are for 25" (64.0 cm)
countertop depth, 24" (61.0 cm) base cabinet depth and
36" (91.4 cm) countertop height.
A
A
B
C
F
D
H
B*
E
I
E**
I
F
D
G
C
A. 30³⁄₄" (78.1 cm)
D. 29⁷⁄₈" (75.9 cm)
B. 35³⁄₄" (90.8 cm) height to underside
of cooktop edge with leveling legs
screwed all the way in*
C. Model/serial number plate (located
on the right-hand side of the
bottom oven frame)
E. 29¹⁄₁₆" (73.8 cm) from
handle to standoff at back
of range**
F. 23½" (59.7 cm)
countertop notch to rear
of cooktop
A. 13" (33.0 cm) upper cabinet
depth
B. 30" (76.2 cm) min. opening
width
C. For minimum clearance to the
top of the cooktop,
see NOTE*.
D. 23¹⁄₄" (59.1 cm) opening
depth
E. 30" (76.2 cm) min. opening
width
F. Junction box - 5.5" (14.0 cm)
min. from either cabinet,
10" (25.4 cm) max. from floor
Outlet must be flush.
Nothing located in shaded
area can extend more than
2" (5.1 cm) from wall or range
will not slide all the way back.
G. Cabinet door or hinge should
not extend into cutout.
*Range can be raised approximately 1" (2.5 cm) by adjusting
the leveling legs.
**When installed in a 24" (61 cm) base cabinet with 25" (63.5 cm)
countertop; front of oven door protrudes 2¹⁄₂" (6.4 cm) beyond
24" (61.0 cm) base cabinet.
H. 18" (45.7 cm)
I. 3" (7.6 cm) min. clearance from
both sides of the range to the
side wall or other combustible
material.
NOTE: 24" (61.0 cm) minimum when bottom of wood or metal
cabinet is covered by not less than ¹⁄₄" (0.64 cm) flame retardant
millboard covered with not less than No. 28 MSG sheet steel,
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or
0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking
platform and the bottom of an uncovered wood or metal cabinet.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
The length of vent system and number of elbows should be kept
to a minimum to provide efficient performance.
Venting Requirements
The maximum equivalent length of the vent system is
60 ft (18.3 m). For altitudes above 4,500 ft (1272 m), reduce
recommended vent run by 20% for best performance.
IMPORTANT: This range must be exhausted outdoors. See
“Venting Methods” section.
■
Do not terminate the vent system in an attic or other enclosed
area.
Cold Weather Installations
An additional backdraft damper should be installed to minimize
backward cold air flow and a thermal break installed to minimize
conduction of outside temperatures as part of the vent system.
The damper should be on the cold air side of the thermal break.
■
■
■
Use a Jenn-Air wall cap.
Vent system must terminate to the outside.
Use only a 6" (15.2 cm) round metal vent or a 3¼ x 10"
(8.3 cm x 25.4 cm) rectangular vent, except as follows:
Makeup Air
Local building codes may require the use of makeup air systems
when using ventilation systems greater than specified CFM of air
movement. The specified CFM varies from locale to locale.
Consult your HVAC professional for specific requirements in your
area.
5" (12.7 cm) round metal vent may be used for venting
straight out the back of the range and directly through the
wall for vent lengths of 10 ft (3.0 m) or less.
■
■
■
Rigid metal vent is recommended. For best performance, do
not use plastic or metal foil vent.
Before making cutouts, make sure there is proper clearance
within the wall or floor for the exhaust vent.
Venting Methods
Common venting methods are shown for a downdraft range. The
downdraft range may be vented through the wall or floor.
Do not cut a joist or stud unless absolutely necessary. If a
joist or stud must be cut, then a supporting frame must be
constructed.
Wall Venting
■
■
The size of the vent should be uniform.
The vent system must have a damper. If roof or wall cap has a
damper, do not use damper supplied with the range hood.
■
■
Use vent clamps to seal all joints in the vent system.
Use caulking to seal exterior wall or roof opening around the
cap.
■
Determine which venting method is best for your application.
For Best Performance:
■
Use 26-gauge minimum galvanized or 25-gauge minimum
aluminum metal vent. Poor quality pipe fittings can reduce
airflow. Flexible metal vent is not recommended.
NOTE: Local codes may require a heavier gauge material.
A
B
■
Metal duct may be reduced to 30-gauge galvanized steel or
26-gauge aluminized steel if allowed by local codes. This
reduction is based on information in the International
Residential Codes Section M1601.1 (2006 edition).
A. Wall cap
B. 6" (15.2 cm) round roof venting
■
■
■
Do not install 2 elbows together.
Floor Venting
Venting Between Floor Joists
Use no more than three 90° elbows.
If an elbow is used, install it as far away as possible from the
hood’s vent motor exhaust opening.
■
■
■
■
■
■
Make sure there is a minimum of 18" (45.7 cm) of straight
vent between the elbows if more than one elbow is used.
Elbows too close together can cause excess turbulence that
reduces airflow.
Do not use a 5" (12.7 cm) elbow in a 6" (15.2 cm) or 3¹⁄₄" x 10"
(8.3 x 25.4 cm) system.
A
Do not reduce to a 5" (12.7 cm) system after using a
6" (15.2 cm) or 3¹⁄₄" x 10" (8.3 x 25.4 cm) fittings.
B
Avoid forming handmade crimps. Handmade crimps may
restrict airflow.
A. Wall cap
B. 6" (15.2 cm) round roof venting
Use a Jenn-Air vent cap for proper performance. If an
alternate wall or roof cap is used, be certain the cap size is
not reduced and that it has a backdraft damper.
■
■
Use vent clamps to seal all joints in the vent system.
Use caulking to seal exterior wall or roof opening around the
cap.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Left or Right Side Venting
Venting Behind Cabinet Kickplate
Calculating Vent System Length
IMPORTANT: This range is rated at 60 ft (18.3 m) of straight duct.
Low range is up to 30 ft (9.1 m); high range is 31 ft (9.4 m) to
60 ft (18.3 m).
If equivalent duct length exceeds 30 ft (18.3 m), the blower must
be converted to high range.
■
Do not convert to high range for shorter lengths. This will
cause excessive noise, conditioned air loss and affect the
flame pattern on gas ranges.
A
■
To convert blower for high range installations, see the
“Install Downdraft System” section.
B
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
A. Wall cap
B. 6" (15.2 cm) round roof venting
Vent Piece
6" (15.2 cm) Round
Concrete Slab Installations - Exhaust Through Wall
45° elbow
2.5 ft
(0.8 m)
B
A
D
90° elbow
5.0 ft
(1.5 m)
C
L
E
F
K
G
I
J
6" (15.2 cm)
wall cap
0.0 ft
(0.0 m)
H
A. Wall cap
B. 6" (15.2 cm) round metal vent
C. 16" (40.6 cm) maximum
D. 6" (15.2 cm) round PVC sewer pipe
E. Concrete slab
F. 6" (15.2 cm) round PVC sewer pipe
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 4.5 ft
to 6" (15.2 cm) transition
(1.4 m)
G. 6" (15.2 cm) round 90° PVC sewer pipe elbow
H. Tightly pack gravel or sand completely around pipe.
I. 30 ft (9.1 m) max.
J. 6" (15.2 cm) round 90° PVC sewer pipe elbow
K. 6" (15.2 cm) round PVC coupling
L. 12" (30.5 cm) minimum
6" (15.2 cm) to 3¹⁄₄" x 10"
(8.3 cm x 25.4 cm) transition
1 ft
(0.3 m)
Concrete Slab Installations -
Exhaust Through Window Well
IMPORTANT: Window well installation for electric models only.
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 5.0 ft
to 6" (15.2 cm) 90° elbow
transition
(1.5 m)
B
D
A
K
C
6" (15.2 cm) to 3¹⁄₄" x 10"
(8.3 cm x 25.4 cm) 90° elbow (1.5 m)
transition
5.0 ft
E
F
H
G
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 5.0 ft
90° elbow
J
(1.5 m)
I
A. Wall cap
B. 12" (30.5 cm) minimum
C. Concrete slab
D. 6" (15.2 cm) round PVC sewer pipe
E. 6" (15.2 cm) round PVC sewer pipe
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 12.0 ft
flat elbow (3.7 m)
F. 6" (15.2 cm) round 90° PVC sewer pipe elbow
G. Tightly pack gravel or sand completely around pipe.
H. 42 ft (12.8 m) max.
I. 6" (15.2 cm) round PVC coupling
J. 6" (15.2 cm) minimum
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 0.0 ft
wall cap (0.0 m)
K. Window well
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Example vent system
Range Rating*
120/240 Volts
Specified Rating of
Power Supply Cord Kit
and Circuit Protection
wall cap
90˚ elbow
6 ft (1.8 m)
120/208 Volts
Amps
8.8 - 16.5 KW
16.6 - 22.5 KW
7.8 - 12.5 KW
12.6 - 18.5 KW
40 or 50**
50
2 ft
(0.6 m)
*The NEC calculated load is less than the total connected load
listed on the model/serial rating plate.
**If connecting to a 50-amp circuit, use a 50-amp rated cord with
kit. For 50-amp rated cord kits, use kits that specify use with a
nominal 1³⁄₈" (34.9 mm) diameter connection opening.
■
A circuit breaker is recommended.
Maximum length
1- 90° elbow
= 60 ft (18.3 m)
= 5 ft (1.5 m)
= 8 ft (2.4 m)
= 0 ft (0 m)
■
The range can be connected directly to the circuit breaker
box (or fused disconnect) through flexible or nonmetallic
sheathed, copper or aluminum cable. See “Electrical
Connection.”
8 ft (2.4 m) straight
1 - wall cap
■
■
Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that
the range can be moved if servicing is ever necessary.
System length
= 13 ft (3.9 m)
A UL listed conduit connector must be provided at each end
of the power supply cable (at the range and at the junction
box).
NOTE: For external venting, flexible vent is not recommended.
Flexible vent creates back pressure and air turbulence that
greatly reduce performance.
■
■
Wire sizes and connections must conform with the rating of
the range.
Electrical Requirements - U.S.A. Only
The wiring diagram is located on the back of the access
panel in a plastic bag.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path and wire gauge are in accordance with local
codes.
If connecting to a 4-wire system:
This range is manufactured with the ground connected to the
neutral by a link. The ground must be revised so the green
ground wire of the 4-wire power supply cord is connected to the
cabinet. See “Electrical Connection.”
Do not use an extension cord.
Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code, ANSI/
NFPA 70-latest edition and all local codes and ordinances.
Grounding through the neutral conductor is prohibited for new
branch-circuit installations (1996 NEC); mobile homes; and
recreational vehicles, or an area where local codes prohibit
grounding through the neutral conductor.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269.
When a 4-wire receptacle of NEMA Type 14-50R is used, a
matching UL listed, 4-wire, 250-volt, 40- or 50-amp, range power
supply cord (pigtail) must be used. This cord contains 4 copper
conductors with ring terminals or open-end spade terminals with
upturned ends, terminating in a NEMA Type 14-50P plug on the
supply end.
WARNING: Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. Check with a
qualified electrician or service technician if you are in doubt as to
whether the appliance is properly grounded. Do not modify the
power supply cord plug. If it will not fit the outlet, have a proper
outlet installed by a qualified electrician.
The fourth (grounding) conductor must be identified by a green or
green/yellow cover and the neutral conductor by a white cover.
Cord should be Type SRD or SRDT with a UL listed strain relief
and be at least 4 ft (1.22 m) long.
Electrical Connection
To properly install your range, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
■
Range must be connected to the proper electrical voltage
and frequency as specified on the model/serial number rating
plate. The model/serial number rating plate is located behind
the control panel or on the oven frame behind the storage
drawer panel. Refer to the figures in the “Product
4-wire receptacle (14-50R)
Dimensions” section of the “Location Requirements” section.
■
This range is manufactured with the neutral terminal
connected to the cabinet. Use a 3-wire, UL listed, 40- or
50-amp power supply cord (pigtail) (see following Range
Rating chart). If local codes do not permit ground through the
neutral, use a 4-wire power supply cord rated at 250 volts,
40 or 50 amps and investigated for use with ranges.
The minimum conductor sized for the copper 4-wire power
cord are:
40-amp circuit
2 No.-8 conductors
1 No.-10 white neutral
1 No.-8 green grounding
7
Download from Www.Somanuals.com. All Manuals Search And Download.
■
■
A time-delay fuse or circuit breaker is recommended.
If connecting to a 3-wire system:
Local codes may permit the use of a UL listed, 3-wire, 250-volt,
40- or 50-amp range power supply cord (pigtail). This cord
contains 3 copper conductors with ring terminals or open-end
spade terminals with upturned ends, terminating in a NEMA Type
10-50P plug on the supply end. Connectors on the appliance end
must be provided at the point the power supply cord enters the
appliance. This uses a 3-wire receptacle of NEMA Type 10-50R.
This range is equipped with a CSA International Certified
Power Cord intended to be plugged into a standard 14-50R
wall receptacle. Be sure the wall receptacle is within reach of
range’s final location.
■
Do not use an extension cord.
3-wire receptacle (10-50R)
Electrical Requirements - Canada Only
WARNING
Countertop Preparation
(for Slide-in Ranges Only)
The cooktop sides of the slide-in range fit over the cutout edge of
your countertop.
If you have a square finish (flat) countertop and the opening width
is 30" (76.2 cm), no countertop preparation is required.
Formed front-edged countertops must have molded edge
shaved flat ³⁄₈" (1.0 cm) from each front corner of opening.
Tile countertops may need trim cut back ³⁄₈" (1.0 cm) from each
front corner and/or rounded edge flattened.
30"
(76.2 cm)
Electrical Shock Hazard
Electrically ground range.
³⁄₈"
(1.0 cm)
Failure to do so can result in death, fire, or
electrical shock.
30 ¾"
(78.1 cm)
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate and wire gauge are in accordance
with local codes.
If countertop opening width is greater than 30" (76.2 cm), adjust
the ³⁄₈" (1.0 cm) dimension.
Be sure that the electrical connection and wire size are adequate
and in conformance with CSA Standard C22.1, Canadian
Electrical Code, Part 1 - latest edition, and all local codes and
ordinances.
Countertop must be level. Place level on countertop, first side to
side, then front to back. If countertop is not level, range will not
be level. Range must be level for satisfactory baking conditions.
A copy of the above code standards can be obtained from:
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA
■
Check with a qualified electrical installer if you are not sure
the range is properly grounded.
Range Rating*
Rating of
Power
Supply Cord
Circuit
Protection
120/240 Volts 120/208 Volts Amps
Amps
8.8 - 16.5 KW 7.8 - 12.5 KW 40
16.6 - 22.5 KW 12.6 - 18.5 KW 50
40 or 50
50
*The NEC calculated load is less than the total connected load
listed on the model/serial rating plate.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
NOTE: If height adjustment is made when range is standing,
tilt the range back to adjust the front legs, then tilt forward to
adjust the rear legs.
Unpack Range
3. When the range is at the correct height, check that there is
adequate clearance under the range for the anti-tip bracket.
Before sliding range into its final location, check that the anti-
tip bracket will slide under the range and onto the rear
leveling leg prior to anti-tip bracket installation.
WARNING
Excessive Weight Hazard
Use two or more people to move and install range.
Failure to do so can result in back or other injury.
Install Anti-Tip Bracket
1. Remove the anti-tip bracket that is taped to the package
1. Remove shipping materials, tape and film from the range.
containing literature.
Keep cardboard bottom under range.
2. Determine which mounting method to use: floor or wall.
2. Remove oven racks and parts package from inside oven.
If you have a stone or masonry floor you can use the wall
mounting method.
3. To remove cardboard bottom, place range on its back, take
4 cardboard corners from the carton. Stack one cardboard
corner on top of another. Repeat with the other 2 corners.
Place them lengthwise on the floor behind the range to
support the range when it is laid on its back.
3. Determine and mark centerline of the cutout space. The
mounting bracket can be installed on either the left side or
right side of the cutout. Position mounting bracket in cutout
so that right (or left) edge of the bracket is 14¹⁄₄" (36.2 cm)
from centerline, as shown.
4. Using 2 or more people, firmly grasp the range and gently lay
it on its back on the cardboard corners.
5. Pull cardboard bottom firmly to remove.
A
6. Use an adjustable wrench to loosen the leveling legs.
7. Place cardboard or hardboard in front of range. Using 2 or
more people, stand range back up onto cardboard or
hardboard.
Adjust Leveling Legs
B
1. If range height adjustment is necessary, use a wrench or
pliers to loosen the 4 leveling legs.
This may be done with the range on its back or with the range
supported on 2 legs after the range has been placed back to
a standing position.
A. Centerline
B. 14¹⁄₄" (36.2 cm)
NOTE: To place range back up into a standing position, put a
sheet of cardboard or hardboard in front of range. Using 2 or
more people, stand range back up onto the cardboard or
hardboard.
4. Drill two ¹⁄₈" (3.0 mm) holes that correspond to the bracket
holes of the determined mounting method. See below.
Floor Mounting
A
B
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
A. #12 x 1⁵⁄₈" screws
B. Anti-tip bracket
Failure to follow these instructions can result in death
or serious burns to children and adults.
2. Adjust the leveling legs to the correct height. Leveling legs
can be loosened to add up to a maximum of 1" (2.5 cm). A
minimum of ³⁄₁₆" (5 mm) is needed to engage the anti-tip
bracket.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Wall Mounting
2. Check for obstructions before marking the vent hole location.
Mark a horizontal line 8³⁄₁₆" (20.8 cm) from the floor. Mark a
vertical line up to a maximum of 2¼" (7.9 cm) from the right-
hand side of the cabinet centerline.
A
A
B
B
A. Maximum 2¼" (7.9 cm) from
the right of center
A. #12 x 1⁵⁄₈" screws
B. 8³⁄₁₆" (20.8 cm) from floor
B. Anti-tip bracket
3. Draw and cut a 6¼" (15.8 cm) diameter hole.
5. Using the Phillips screwdriver, mount anti-tip bracket to the
wall or floor with the two #12 x 1⁵⁄₈" screws provided.
A
Install Downdraft System
Determine Equivalent Length of Vent System
This range is equipped with a dual range blower. It is shipped
from the factory for Low Range installations. If vent system
equivalent length exceeds 30 ft (9.1 m), the downdraft blower
motor must be converted to High Range for best performance.
See “Calculating Vent System Length.”
A. 6¼" (15.8 cm)
To Convert:
4. Position blower motor in cabinet opening. Connect vent
system to blower motor outlet using a vent clamp.
Gently remove the spring loaded Restricter Ring from the blower
inlet by pressing one of the 3 springs.
Top View
E
C
D
A
B
B
A
A. 18¾" (47.6 cm) maximum from back
wall forward into cabinet opening
B. Inlet
A. Restricter ring
B. Spring
C. Vent system
D. Vent clamp
E. Wall vent
Determine which venting method to use: floor, rear wall, or left or
right side venting. Go to the section for your type of venting.
Rear Wall Venting
1. Mark the wall at the center of the cabinet opening.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Mount blower motor to the floor with 4 - #8 x ¾" hex head
NOTE: If the template is misplaced, the following
measurements can be used to determine the vent hole
location.
screws provided.
Top View
Top View
B
C
D
A
E
F
G
I
H
6. Go to the “Electrical Connection” section.
A. 9" (22.8 cm)
B. 3¹⁄₈" (7.9 cm)
C. 8³⁄₈" (21.3 cm)
D. 6³⁄₈" (16.2 cm)
E. 2¼" (5.7 cm)
F. 12½" (31.7 cm)
G. 18¾" (47.6 cm)
H. 1½" (3.8 cm)
I. 3½" (8.9 cm)
Floor Venting
1. Mark the floor at the center of the cabinet opening.
4. Draw and cut a 6¼" (15.8 cm) diameter hole (option 1 shown).
2. Position template on floor by matching the centerline of the
template to the centerline drawn on the floor and place
template 2¼" (5.7 cm) from the back wall.
3. Determine the correct position for the vent hole, depending
B
A
on obstructions (joists) in the floor.
The hole can be cut anywhere within the boundaries of either
hatched area.
A. Option 1
B. Option 2
Option 1: If using the back hatched area (bigger one), the
blower inlet must face the left side as shown on the template
5. Position blower motor in cabinet opening and mount blower
motor to the floor.
Option 2: If using the front hatched area (smaller one), the
blower inlet must face the back.
Top View
Option 1
Option 2
Top View
Option 1
Option 2
B
B
A
A
A
A
B
B
A. Inlet from range
B. Exhaust outlet
A. Inlet from range
B. Exhaust outlet
11
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Connect vent system to blower motor outlet (option 1 shown)
3. Mark and cut a 14" x 11" (35.6 x 27.9 cm) opening in the floor
with 4 - #8 x ¾" hex head screws provided.
of the same cabinet as the vent hole opening.
Top View
A
B
A
B
C
D
A. Inlet
B. Vent clamp
C. Floor
D. Vent system
A. 11" (27.9 cm) from front of cabinet
B. 14" (35.6 cm) from left side of cabinet
4. Remove 4 locknuts on the motor side of the blower and
7. Go to the “Electrical Connection” section.
remove the bracket.
View from Motor Side of Blower
Left or Right Side Venting
1. Mark cabinet side for either a left or right side vent hole
location.
A
A
B
A.Electrical connector
A. 31³⁄₁₆" (79.2 cm) to top of cabinet
B. 18" (45.7 cm) from back wall
5. Lift and rotate the motor 180° to reposition the electrical
connection.
2. Mark and cut a 5½" (13.9 cm) diameter hole in the desired
cabinet side.
A
A
A. Electrical connector
A. 5½" (13.9 cm) diameter hole
6. Rotate bracket 180° and secure with 4 locknuts.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
7. Remove the bracket from the other side of the blower motor,
9. Mount blower motor to wood spacers using 4 - #8 x ¾" hex
rotate 180° and secure with 4 locknuts.
head screws provided.
NOTE: Vent system will be connected after range has been
moved into it’s final location. “See Connect Range to
Downdraft System” section.
Top View
B
C
8. Position 2 wood spacers and mount them to the floor.
Top View
A
B
C
A. Wood spacers
B. Mounting bracket
C. Blower
A
D
D
10. Go to the “Electrical Connection” section.
A. 2" x 4" (5.0 x 10.2 cm) wood spacers
B. 2⁷⁄₉" (7.3 cm) from back wall to edge of wood spacer
C. 8¾" (22.2 cm)
D. 2⁵⁄₁₆" (5.8 cm) centerline of opening to wood spacer
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical Connection - U.S.A. Only
Power Supply Cord
Direct Wire
WARNING
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper or 6 gauge aluminum wire.
Electrically ground range.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Failure to follow these instructions can result in death,
fire, or electrical shock.
1. Disconnect power.
Style 1: Power supply cord strain relief
2. Use Phillips screwdriver to remove the terminal block cover
screw located on the back of the range. Pull cover down and
toward you to remove cover.
■
Assemble a UL listed strain relief in the opening.
A
3. Remove plastic tag holding three 10-32 hex nuts from the
middle post of the terminal block.
A. UL listed strain relief
■
■
Feed the power supply cord through the opening in the
cord/conduit plate on bottom of range. Allow enough
slack to easily attach the wiring to the terminal block.
Tighten strain relief screw against the power supply cord.
4. Add strain relief.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Style 2: Direct wire strain relief
■
Replace cord/conduit plate and insert screws.
■
Use Phillips screwdriver to remove screws from panel on
back of range.
U
S
O
R
V
E
P
T
P
O
G
!
C
C
E
A
D
A
E
M
O
I
T
H
W
E
E
T
R
NQ
W
E
T
IQ
U
S
EL
CO
T
S
S
I
E
L
A
T
R
U
L
E
C
T
R
I
E
A
COELÉC
N
T
P
ARDÓN
CO
■
Assemble a UL listed conduit connector in the opening.
■
Lift range back panel up and off.
A
B
U
D
D
A
VP
P
E
A
T
T
T
I
S
L
E
A
R
L
N
T
T
L
E
OEÉ
P
D
A. Removable retaining nut
B. Strain relief
■
■
Feed the flexible conduit through the strain relief, allowing
enough slack to easily attach wiring to the terminal block.
Tighten strain relief screw against the flexible conduit.
■
Use Phillips screwdriver to remove screws and slide
cord/conduit plate down and out.
5. Replace back panel and screws on rear of range.
6. Complete installation following instructions for your type of
electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
■
Position cord/conduit plate as shown in the following
illustration.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical Connection Options
3. Feed the power supply cord through the opening in the cord/
conduit plate on bottom of range. Allow enough slack to
easily attach the wiring to the terminal block.
If your home has:
And you will be Go to Section:
connecting to:
4-wire receptacle
(NEMA type 14-50R)
A UL listed,
250-volt
4-wire connection:
Power supply cord
minimum,
40-amp, range
power supply
cord
A
4-wire direct
A fused
4-wire connection:
Direct wire
B
disconnect or
circuit breaker
box
5"
(12.7 cm)
3-wire receptacle
(NEMA type 10-50R)
A UL listed,
250-volt
3-wire connection:
Power supply cord
minimum,
40-amp, range
power supply
cord
C
D
3-wire direct
A fused
3-wire connection:
Direct wire
1"
disconnect or
circuit breaker
box
(2.5 cm)
A. Terminal block
B. Ground-link screw
C. Cord/conduit plate
D. Power supply cord wires
3"
(7.6 cm)
4. Use Phillips screwdriver to connect the green ground wire
from the power supply cord to the range with the ground-link
screw. The ground wire must be attached first.
4-wire connection: Power Supply Cord
Use this method for:
5. Use ³⁄₈" nut driver to connect the neutral (white) wire to the
■
■
■
■
New branch-circuit installations (1996 NEC)
center terminal block post with one of the 10–32 hex nuts.
Mobile homes
Recreational vehicles
In an area where local codes prohibit grounding through the
neutral
A
F
1. Part of metal ground strap must be cut out and removed.
B
A
B
C
E
C
D
A. 10–32 hex nut
B. Ground-link screw
C. Line 1 (black)
D. Green ground wire
E. Neutral (center) wire
F. Line 2 (red)
A. Metal ground strap
B. Discard
C. Ground-link screw
6. Connect line 1 (black) and line 2 (red) wires to the outer
2. Use Phillips screwdriver to remove the ground-link screw
from the back of the range. Save the ground-link screw and
the end of the ground-link under the screw.
terminal block posts with 10-32 hex nuts.
7. Securely tighten hex nuts.
NOTE: For power supply cord replacement, only use a power
cord rated at 250 volts minimum, 40 amps or 50 amps that is
marked for use with nominal 1³⁄₈" (3.5 cm) diameter
connection opening, with ring terminals and marked for use
with ranges.
8. Replace terminal block access cover.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
3-wire connection: Power Supply Cord
Direct Wire Installation: Copper or Aluminum Wire
Use this method only if local codes permit connecting chassis
ground conductor to neutral wire of power supply cord.
This range may be connected directly to the fuse disconnect or
circuit breaker box. Depending on your electrical supply, make
the required 3-wire or 4-wire connection.
1. Feed the power supply cord through the opening in the cord/
conduit plate on bottom of range. Allow enough slack to
easily attach the wiring to the terminal block.
1. Strip outer covering back 3" (7.6 cm) to expose wires. Strip
the insulation back 1" (2.5 cm) from the end of each wire.
1"
(2.5 cm)
A
3"
(7.6 cm)
B
2. Allow enough slack in the wire to easily attach the wiring
terminal block.
3. Complete electrical connection according to your type of
electrical supply (4-wire or 3-wire connection).
4-wire Connection: Direct Wire
Use this method for:
■
■
■
■
New branch-circuit installations (1996 NEC)
Mobile homes
C
D
Recreational vehicles
In an area where local codes prohibit grounding through the
neutral
A. Terminal block
B. Ground-link screw
C. Cord/conduit plate
D. Power supply cord wires
1. Part of metal ground strap must be cut out and removed.
2. Use ³⁄₈" nut driver to connect the neutral (white) wire to the
center terminal block post with one of the 10–32 hex nuts.
A
B
C
A
E
A. Metal ground strap
B. Discard
C. Ground-link screw
2. Use Phillips screwdriver to remove the ground-link screw
from the back of the range. Save the ground-link screw and
the end of the ground-link under the screw.
D
B
C
A. 10–32 hex nut
B. Line 1 (black)
D. Neutral (white) wire
E. Line 2 (red)
C. Ground-link screw
3. Connect line 1 (black) and line 2 (red) wires to the outer
terminal block posts with 10-32 hex nuts.
4. Securely tighten hex nuts.
NOTE: For power supply cord replacement, only use a power
cord rated at 250 volts minimum, 40 amps or 50 amps that is
marked for use with nominal 1³⁄₈" (3.5 cm) diameter
connection opening, with ring terminals and marked for use
with ranges.
5. Replace terminal block access cover.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Pull the conduit through the strain relief on cord/conduit plate
on bottom of range. Allow enough slack to easily attach
wiring to the terminal block.
5. Use Phillips screwdriver to connect the bare (green) ground
wire to the range with the ground-link screw. The ground wire
must be attached first and must not contact any other
terminal.
6. Use ³⁄₈" nut driver to connect the neutral (white) wire to the
center terminal block post with one of the 10–32 hex nuts.
A
B
C
G
A
B
F
D
E
C
G
D
A. 10–32 hex nut
B. Line 1 (black)
E. Neutral (white) wire
F. Line 2 (red)
F
E
C. Bare (green) ground wire
D. Ground-link screw
G. Terminal lug
A. Terminal block
E. Neutral (white) wire
F. Line 1 (black) wire
G. Bare (green) ground wire
B. Ground-link screw
C. Cord/conduit plate
D. Line 2 (red) wire
7. Connect line 1 (black) and line 2 (red) wires to the outer
terminal block posts with 10-32 hex nuts.
8. Securely tighten hex nuts.
9. Replace terminal block access cover.
4. Attach terminal lugs to line 1 (black), neutral (white), and line 2
(red) wires. Loosen (do not remove) the set screw on the front
of the terminal lug and insert exposed wire end through
bottom of terminal lugs. Securely tighten set screw to torque
as shown in the following Bare Wire Torque Specifications
chart.
3-wire connection: Direct Wire
Use this method only if local codes permit connecting ground
conductor to neutral supply wire.
A
1. Pull the conduit through the hole and conduit plate on bottom
of range. Allow enough slack to easily attach the wiring to the
terminal block.
B
A
C
D
E
B
A. Terminal lug
B. Set screw
C. Line 1 (black) wire
D. Neutral (white) wire
E. Line 2 (red) wire
C
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)
D
Wire Awg
Torque
F
E
8 gauge copper
25 lbs-in. (2.8 N-m)
35 lbs-in. (4.0 N-m)
A. Terminal block
B. Ground-link screw
C. Cord/conduit plate
D. Line 2 (red) wire
E. Bare (green) ground wire
F. Line 1 (black) wire
6 gauge aluminum
18
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Attach terminal lugs to line 1 (black), bare (green) ground, and
line 2 (red) wires. Loosen (do not remove) the set screw on the
front of the terminal lug and insert exposed wire end through
bottom of terminal lugs. Securely tighten set screw to torque
as shown in the following Bare Wire Torque Specifications
chart.
Connect Range to Downdraft System
1. Attach flexible vent (provided) to the blower motor inlet using
a vent clamp.
A
B
C
D
E
A
B
A. Inlet flexible vent
B. Vent clamp
A. Terminal lug
B. Set screw
2. Check countertop height to allow range top to clear
C. Line 1 (black) wire
D. Bare (green) ground wire
E. Line 2 (red) wire
countertop. Adjusting leveling legs if necessary.
3. Remove access panel by grasping both sides, pulling
upward, and lifting out.
Bare Wire Torque Specifications
4. Move range close to cabinet opening.
Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)
5. Plug range into grounded outlet (if using a power supply
cord).
Wire Awg
Torque
6. Plug range electrical connector into the downdraft blower
8 gauge copper
25 lbs-in. (2.8 N-m)
35 lbs-in. (4.0 N-m)
motor.
6 gauge aluminum
3. Use ³⁄₈" nut driver to connect the bare (green) ground wire to
the center terminal block post with one of the 10–32 hex nuts.
F
E
A
A
B
B
A. Power supply cord (on some installations)
B. Range electrical connector to blower motor
D
C
7. Remove cardboard or hardboard from under the range. Using
A. 10–32 hex nut
B. Line 1 (black)
D. Bare (green) ground wire
E. Line 2 (red)
2 or more people, gently move range into its final location.
C. Ground-link screw
F. Terminal lug
4. Connect line 1 (black) and line 2 (red) wires to the outer
terminal block posts with 10-32 hex nuts.
5. Securely tighten hex nuts.
6. Replace terminal block access cover.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
8. Check that the anti-tip bracket is installed and that electrical
cords are not kinked. Use a flashlight to look underneath the
bottom of the range.
Floor Venting
Top View
■
Look for the anti-tip bracket securely attached to floor or
wall.
B
■
Slide range back so rear range foot is under anti-tip
bracket.
A
C
9. Level the range.
A. Range
B. Floor venting outlet
C. Vent clamp
a.) Place rack in oven.
b.) Place level on rack and check levelness of the range, first
side to side; then front to back.
Side Venting (left side venting shown)
Connect flexible vent duct to range and connect vent system
to blower motor outlet.
Top View
A
c.) If range is not level, pull range forward until rear leveling
leg is removed from the anti-tip bracket.
d.) Use a wrench or pliers to adjust leveling legs up or down
E
until range is level.
e.) Push range back into position.
f.) Check that rear leveling leg is engaged in anti-tip bracket.
NOTE: Range must be level for satisfactory baking performance.
10. Depending on your installation, connect the flexible vent from
the blower motor inlet to the range using a vent clamp.
Wall Venting
D
Top View
C
B
B
A. Flexible vent duct to range
B. Vent clamp
D. Vent system
E. Side venting outlet
C. Range
11. Replace access panel.
A
C
A. Range
B. Wall venting outlet
C. Vent clamp
20
Download from Www.Somanuals.com. All Manuals Search And Download.
12. Insert downdraft vent filter and place vent cover over
If you need Assistance or Service:
opening.
Please reference the “Assistance or Service” section of the Use
and Care Guide or contact the dealer from whom you purchased
your range.
B
Moving the Range
A
WARNING
A. Filter
B. Grate
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
13. Reconnect power.
Complete Installation
1. Check that all parts are now installed. If there is an extra part,
Failure to follow these instructions can result in death
or serious burns to children and adults.
go back through the steps to see which step was skipped.
2. Check that you have all of your tools.
3. Dispose of/recycle all packaging materials.
When moving range, slide range onto cardboard or hardboard to
avoid damaging the floor covering.
4. Check that the range is level. See “Connect Range to
Downdraft System.”
If removing the range is necessary for cleaning or maintenance:
5. Use a mild solution of liquid household cleaner and warm
water to remove waxy residue caused by shipping material.
Dry thoroughly with a soft cloth. For more information, read
the “Range Care” section of the Use and Care Guide.
For power supply cord-connected ranges:
1. Disconnect range from downdraft vent system.
2. Slide range forward.
6. Read “Range Use” in the range Use and Care Guide.
3. Unplug the power supply cord.
4. Complete cleaning or maintenance.
5. Plug in power supply cord
7. Turn on surface burners and oven. See the Use and Care
Guide for specific instruction on range operation.
If range does not operate, check the following:
6. Check that anti-tip bracket is installed, remove access panel
and use a flashlight to look underneath the bottom of the
range:
■
Household fuse is intact and tight; or circuit breaker has not
tripped.
■
■
■
Range is plugged into an outlet.
■
Look for the anti-tip bracket securely attached to floor or
wall.
Electrical supply is connected.
■
Slide range back so rear range foot is under anti-tip
bracket.
See “Troubleshooting” in the Use and Care Guide.
When the range has been on for 5 minutes, check for heat. If
range is cold, turn off the range and contact a qualified
technician.
8. Use the Flow Tester Card provided with your range to check
the airflow (see card for step-by-step instructions).
7. Check that range is level.
8. Reconnect range to downdraft vent system.
If there is not sufficient airflow, review the “Venting
Requirements” and “Venting Methods” sections.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Complete cleaning or maintenance.
For direct-wired ranges:
5. To check that anti-tip bracket is installed, remove access
panel and use a flashlight and look underneath the bottom of
the range:
WARNING
■
Look for the anti-tip bracket securely attached to floor or
wall.
■
Slide range back so rear range foot is under anti-tip
bracket.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
6. Check that range is level.
2. Disconnect range from downdraft vent system.
3. Slide range forward.
7. Reconnect range to the downdraft vent system.
8. Reconnect power.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
SÉCURITÉ DE LA CUISINIÈRE
Votre sécurité et celle des autres est très importante.
Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de
toujours lire tous les messages de sécurité et de vous y conformer.
Voici le symbole d’alerte de sécurité.
Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous
et à d’autres.
Tous les messages de sécurité suivront le symbole d’alerte de sécurité et le mot “DANGER” ou
“AVERTISSEMENT”. Ces mots signifient :
Risque possible de décès ou de blessure grave si vous ne
suivez pas immédiatement les instructions.
DANGER
Risque possible de décès ou de blessure grave si vous
ne suivez pas les instructions.
AVERTISSEMENT
Tous les messages de sécurité vous diront quel est le danger potentiel et vous disent comment réduire le risque de blessure et
ce qui peut se produire en cas de non-respect des instructions.
AVERTISSEMENT
Risque de basculement
Un enfant ou une personne adulte peut faire basculer la cuisinière ce qui peut causer un décès.
Joindre la bride antibasculement au pied arrière de la cuisinière.
Joindre de nouveau la bride antibasculement si la cuisinière est déplacée.
Le non-respect de ces instructions peut causer un décès ou des brûlures graves aux enfants et
aux adultes.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
EXIGENCES D’INSTALLATION
En cas d’utilisation d’un cordon d’alimentation électrique :
■
Cordon d’alimentation (homologation UL) conçu pour
l’utilisation avec une cuisinière. Pour service 250 volts
minimum, 40 A ou 50 A, compatible avec une ouverture de
diamètre nominal 1³⁄₈" (3,5 cm) pour le raccordement, et avec
cosses rondes ou en fourche à pointes relevées à l’extrémité
de chaque conducteur.
Outils et pièces
Rassembler les outils et composants nécessaires avant
d’entreprendre l’installation. Lire et observer les instructions
fournies avec chacun des outils de la liste ci-dessous.
Outils nécessaires
■
■
■
■
■
Mètre-ruban
■
■
■
■
■
■
Clé ou pince
■
Un serre-câble (homologation UL).
Niveau
Tourne-écrou de ⁵⁄₁₆"
Tourne-écrou de ¼"
Perceuse
Consulter les codes locaux. Vérifier l’alimentation électrique
existante. Voir la section “Spécifications électriques”.
Tournevis Phillips
Tournevis à lame plate
Il est recommandé de faire réaliser tous les raccordements
électriques par un électricien qualifié agréé.
Scie sauteuse ou scie à
guichet
Foret de ¹⁄₈" (3,2 mm)
Foret à maçonnerie à pointe
carburée de ³⁄₁₆" (4,8 mm)
(pour planchers en béton/
céramique)
Exigences d’emplacement
■
Marqueur ou crayon
IMPORTANT : Observer les dispositions de tous les codes et
règlements en vigueur.
■
C’est à l’installateur qu’incombe la responsabilité de
respecter les distances de séparation exigées, spécifiées sur
la plaque signalétique de l’appareil. La plaque signalétique
est située sur le côté droit du châssis du four, derrière le
panneau du tiroir de remisage.
Pièces fournies
Vérifier que toutes les pièces sont présentes.
■
3 écrous hexagonaux de #10-32 (vissés au boîtier de
connexion)
■
■
La cuisinière doit être installée à un endroit pratique dans la
cuisine.
■
■
■
■
■
■
■
■
■
3 attaches de bornes
2 ou 3 grilles de four (en fonction du modèle)
Moteur du ventilateur
Afin de supprimer le risque de brûlures ou d’incendie lié au
fait de se pencher au-dessus des plaques de cuisson
chaudes, les meubles de rangement au-dessus des plaques
doivent être évités. Si des placards de rangement sont
envisagés, le risque peut être réduit par l’installation d’une
hotte de cuisine dépassant le bas des placards d’au moins 5"
(12,7 cm) horizontalement.
2 brides pour conduit
Conduit flexible
Fiche de test du débit
Gabarit pour l’emplacement du ventilateur
4 vis n° 8 x ¾" (pour le montage de la bride du ventilateur)
■
■
Respecter les dimensions indiquées pour les ouvertures à
découper dans les placards. Ces dimensions constituent les
valeurs minimales des dégagements.
2 vis n° 12 x 1⁵⁄₈" (pour le montage de la bride
antibasculement)
La bride antibasculement de plancher doit être installée. Pour
l’installation de la bride antibasculement fournie avec la
cuisinière, voir la section “Installation de la bride
antibasculement”.
■
Bride antibasculement (fixée par du ruban adhésif à la
pochette contenant la documentation dans la cavité du four)
La bride antibasculement doit être bien fixée à la cloison
arrière ou au plancher. La profondeur du plancher peut
nécessiter des vis plus longues pour l’ancrage de la bride
dans le sous-plancher. Des vis plus longues sont disponibles
auprès de votre quincaillerie locale.
■
Une source d’électricité avec liaison à la terre est nécessaire.
Voir la section “Spécifications électriques”.
IMPORTANT : Afin d’éviter d’endommager les placards,
consulter le constructeur de la maison ou le fabricant des
placards pour déterminer si les matériaux utilisés peuvent subir
un changement de couleur, une déstratification ou d’autres
dommages. Ce four a été conçu conformément aux exigences
des normes UL et CSA International et respecte les températures
maximales permises de 194°F (90°C) pour les placards en bois.
Pièces nécessaires
■
L’une des bouches de décharge murales Jenn-Air suivantes :
Clapet de décharge mural en surface rond Jenn-Air® de
5" (12,7 cm). Commander la pièce n° A405.
Clapet de décharge mural en surface rond Jenn-Air® de
6" (15,2 cm). Commander la pièce n° A406.
Clapet de décharge mural en surface Jenn-Air® 3¼" x 10"
(8,3 x 25,4 cm). Commander la pièce n° A403.
Résidence mobile – Spécifications additionnelles à
respecter lors de l’installation
L’installation de cette cuisinière doit être conforme aux
dispositions de la norme Manufactured Home Construction and
Safety Standard, Title 24 CFR, Part 3280 (anciennement Federal
Standard for Mobile Home Construction and Safety, Title 24,
HUD Part 280). Lorsque cette norme n’est pas applicable,
l’installation doit satisfaire aux critères de la norme Standard for
Manufactured Home Installations, ANSI A225.1/NFPA 501A ou
aux dispositions des codes locaux.
Pour commander, voir la section “Assistance ou service” du
Guide d’utilisation et d’entretien.
■
■
■
■
Conduit métallique
Brides pour conduit
Chevilles à béton (pour montage sur sol en béton)
2 cales en bois 2" x 4" x 8¾" (5 x 10,2 x 22,2 cm) (pour
évacuation par la gauche ou par la droite)
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Autres critères à respecter pour une installation en résidence
mobile :
Dimensions du placard
■
Dans le cas de l’installation de cette cuisinière dans une
résidence mobile, la cuisinière doit être fixée au plancher
durant tout déplacement du véhicule. Toute méthode de
fixation de la cuisinière est adéquate dans la mesure où elle
satisfait aux critères des normes mentionnées ci-dessus.
Les dimensions de l’espace entre les placards correspondent à
une installation entre des placards de 24" (61,0 cm) de
profondeur, avec plan de travail de 25" (64 cm) de profondeur et
de 36" (91,4 cm) de hauteur.
■
Pour une installation en résidence mobile, un câble ou cordon
d’alimentation à quatre fils doit être utilisé. Le câblage de
l’appareil devra être révisé. Voir la section “Raccordement
électrique”.
A
B
C
Dimensions du produit
D
H
E
I
A
I
F
F
G
B*
E**
A. Profondeur des placards
supérieurs : 13" (33 cm)
B. Largeur de l’ouverture
30" (76,2 cm) min.
C. Pour le dégagement vertical
minimal de la table de
cuisson, voir la REMARQUE*.
D. Profondeur d'ouverture de
¹⁄₄" (59,1 cm)
E. Largeur de l’ouverture
30" (76,2 cm) min.
F. Boîtier de connexion :
5,5" (14 cm) min. de l’un des
deux placards, 10" (25,4 cm)
max. du plancher. La prise
doit être en affleurement.
Aucun élément situé dans la
zone ombrée ne doit
D
C
dépasser de plus de
2" (5,1 cm) du mur, sinon il
sera impossible de glisser la
cuisinière jusqu’au fond.
G. La porte ou charnière du
placard ne doit pas dépasser
à l’intérieur de l’ouverture.
A. 30³⁄₄" (78,1 cm)
D. 29⁷⁄₈" (75,9 cm)
B. Hauteur jusqu’à la partie
inférieure du bord de la
table de cuisson avec les
pieds de nivellement
E. 29¹⁄₁₆" (73,8 cm) de la
poignée au support à
l’arrière de la cuisinière**
F. 23½" (59,7 cm) du coin du
plan de travail à l’arrière
de la table de cuisson
H. 18" (45,7 cm)
I. Dégagement de 3" (7,6 cm)
min. entre les deux côtés de
la cuisinière et les parois
latérales ou d’autres
complètement rétractés :
35³⁄₄" (90,8 cm)*
C. Plaque signalétique (située
en bas à droite du châssis
du four)
matériaux combustibles.
REMARQUE : Distance de séparation minimale de 24" (61 cm)
lorsque le fond d’un placard de bois ou de métal est protégé par
une planche ignifugée d’au moins ¹⁄₄" (0,64 cm) recouverte d’une
feuille métallique d’épaisseur égale ou supérieure à : acier calibre
28 MSG, acier inoxydable 0,015" (0,4 mm), aluminium
0,024" (0,6 mm), ou cuivre 0,020" (0,5 mm).
*La cuisinière peut être surélevée d’environ 1" (2,5 cm) en
ajustant les pieds de nivellement.
**Dans le cas d’une installation entre des placards de
24" (61 cm) avec plan de travail de 25" (63,5 cm), l’avant
de la porte du four dépassera les placards inférieurs de
24" (61 cm) d'une distance de 2¹⁄₂" (6,4 cm).
Distance de séparation minimale de 30" (76,2 cm) ou plus entre le
dessus de la table de cuisson et le fond d’un placard de bois ou
de métal non protégé.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Exigences concernant l’évacuation
IMPORTANT : Cette cuisinière doit être ventilée vers l’extérieur.
Voir la section “Méthodes d’évacuation”.
■
■
■
Ne pas installer 2 coudes successifs.
Ne pas utiliser plus de trois coudes à 90°.
■
Ne pas terminer le circuit d’évacuation dans un grenier ou
dans un autre espace fermé.
Si un coude est utilisé, on doit le placer le plus loin possible
de l’ouverture de décharge du ventilateur de la hotte.
■
■
■
Utiliser une bouche de décharge murale Jenn-Air.
Le circuit doit évacuer l’air à l’extérieur.
■
■
■
■
Veiller à incorporer une section de conduit rectiligne d’au
moins 18" (45,7 cm) entre deux raccords coudés adjacents.
Utiliser uniquement un conduit métallique rond de
6" (15,2 cm) ou un conduit rectangulaire de 3¼ x 10"
(8,3 cm x 25,4 cm), sauf dans les cas suivants :
Des coudes trop rapprochés peuvent occasionner une
turbulence excessive qui réduit la circulation de l’air.
Ne pas utiliser de coude de 5" (12,7 cm) dans un circuit de
6" (15,2 cm) ou 3¹⁄₄" x 10" (8,3 x 25,4 cm).
Un conduit métallique rond de 5" (12,7 cm) peut être utilisé
pour une évacuation directement depuis l’arrière de la
cuisinière à travers le mur sur une longueur de 10 pi (3,0 m)
au maximum.
Ne pas effectuer de réduction en un circuit de 5" (12,7 cm)
après avoir utilisé des raccords de 6" (15,2 cm) ou 3¼" x 10"
(8,3 x 25,4 cm).
■
■
■
Un conduit en métal rigide est recommandé. Pour des
performances optimales, ne pas utiliser de conduit de
plastique ou d’aluminium.
■
■
Éviter les assemblages par sertissage à la main. Les
sertissages à la main peuvent réduire la circulation d’air.
Utiliser une bouche de décharge Jenn-Air. Si une autre
bouche de décharge de toit ou murale est utilisée, s’assurer
que ses dimensions ne sont pas plus petites et qu’elle est
équipée d’un clapet anti-retour.
Avant d’effectuer des découpes, s’assurer que l’espace est
suffisant sur le mur ou le plancher pour le conduit
d’évacuation.
On ne doit couper un poteau de colombage ou une solive
que si c’est absolument nécessaire. Dans ce cas, on devra
construire une structure de support appropriée.
■
■
Pour assurer l’étanchéité de toutes les jonctions du circuit
d’évacuation, utiliser des brides pour conduit.
À l’aide d’un produit de calfeutrage, assurer l’étanchéité
autour de la bouche de décharge à l’extérieur (à travers le
mur ou le toit).
■
■
La taille du conduit doit être uniforme.
Le circuit d’évacuation doit comporter un clapet anti-retour.
Si la bouche de décharge murale ou par le toit comporte un
clapet, ne pas utiliser le clapet fourni avec la hotte de
cuisinière.
La longueur du système d’évacuation et le nombre de coudes
doit être réduit au minimum pour une performance optimale.
La longueur équivalente maximale du circuit d’évacuation est de
60 pi (18,3 m). À une altitude supérieure à 4500 pi (1272 m),
réduire la longueur de 20 % pour une meilleure performance.
■
■
Pour assurer l’étanchéité de toutes les jonctions du circuit
d’évacuation, utiliser des brides pour conduit.
À l’aide d’un produit de calfeutrage, assurer l’étanchéité
autour de la bouche de décharge à l’extérieur (à travers le
mur ou le toit).
Installations dans les régions au climat froid
On devrait installer un clapet anti-retour additionnel pour
minimiser le reflux d’air froid et installer une barrière thermique
pour minimiser la conduction des températures extérieures par
l’intermédiaire du conduit d’évacuation. Le clapet anti-retour être
placé du côté air froid de la barrière thermique.
■
Déterminer la méthode d’évacuation la plus appropriée.
Pour obtenir des performances optimales :
■
Utiliser un conduit métallique en acier galvanisé de calibre
26 minimum ou en aluminium de calibre 25 minimum. Des
raccords de tube de qualité médiocre peuvent réduire la
circulation d’air. On déconseille l’emploi d’un conduit en
métal flexible.
Air d’appoint
Les codes locaux en bâtiment peuvent imposer l’emploi d’un
circuit de renouvellement de l’air/introduction d’air d’appoint, lors
de l’utilisation d’un circuit d’aspiration de débit supérieur à une
valeur spécifiée en pieds cubes par minute. Le débit spécifié en
pieds cubes par minute varie d’une juridiction à l’autre. Consulter
un professionnel des installations de chauffage/ventilation/
climatisation au sujet des exigences spécifiques applicables
dans la juridiction locale.
REMARQUE : Les codes locaux peuvent imposer un
matériau d’épaisseur supérieure.
■
Les conduits métalliques peuvent être réduits à de l’acier
galvanisé de calibre 30 ou de l’acier aluminisé de calibre 26 si
les codes locaux l’autorisent. Cette réduction repose sur les
informations du document International Residential Codes
Section M1601.1 (édition 2006).
26
Download from Www.Somanuals.com. All Manuals Search And Download.
Méthodes d’évacuation
Les méthodes communes d’évacuation sont illustrées pour une
cuisinière à aspiration par le bas. L’évacuation de la cuisinière à
aspiration par le bas peut se faire par le mur ou le plancher.
Installations sur dalle de béton - Évacuation par le mur
B
A
Évacuation par le mur
D
C
L
E
F
K
G
I
J
H
A. Bouche de décharge murale
B. Conduit métallique rond de dia. 6" (15,2 cm)
C. 16" (40,6 cm) maximum
D. Conduit PVC dia. 6" (15,2 cm) (pour égout)
E. Dalle de béton
F. Conduit PVC dia. 6" (15,2 cm) (pour égout)
G. Coudé à 90° PVC dia. 6" (15,2 cm) (pour égout)
H. Gravier ou sable compacté tout autour du tuyau
I. 30 pi (9,1 m) max.
J. Coudé à 90° PVC dia. 6" (15,2 cm) (pour égout)
K. Raccord PVC dia. 6" (15,2 cm)
A
B
A. Bouche de décharge murale
B. Conduit de dia. 6" (15,2 cm) –
sortie à travers le toit
L. 12" (30,5 cm) minimum
Évacuation par le plancher
Évacuation entre solives de plancher
Installations sur dalle de béton
- Évacuation par un puits de fenêtre
IMPORTANT : Installation à travers un puits de fenêtre pour
modèles électriques uniquement.
B
D
A
K
C
E
A
F
H
B
G
J
A. Bouche de décharge murale
B. Conduit de dia. 6" (15,2 cm) – sortie à travers le toit
I
A. Bouche de décharge murale
B. 12" (30,5 cm) minimum
C. Dalle de béton
D. Conduit PVC dia. 6" (15,2 cm) (pour égout)
E. Conduit PVC dia. 6" (15,2 cm) (pour égout)
F. Coudé à 90° PVC dia. 6" (15,2 cm) (pour égout)
G. Gravier ou sable compacté tout autour du tuyau
H. 42 pi (12,8 m) max.
Évacuation par la gauche ou par la droite
Évacuation derrière les garde-pieds des placards
I. Raccord PVC dia. 6" (15,2 cm)
J. 6" (15,2 cm) minimum
K. Puits de fenêtre
A
B
A. Bouche de décharge murale
B. Conduit de dia. 6" (15,2 cm) – sortie à travers le toit
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Calcul de la longueur effective du circuit d’évacuation
IMPORTANT : Cette cuisinière accepte jusqu’à 60 pi (18,3 m)
de conduit droit. Le mode à faible aspiration admet jusqu’à
30 pi (9,1 m); le mode à forte aspiration admet de 31 pi (9,4 m) à
60 pi (18,3 m).
Coudé à 90° de
6" (15,2 cm) vers 3¹⁄₄" x 10"
(8,3 cm x 25,4 cm)
5 pi
(1,5 m)
Si la longueur équivalente de conduit dépasse 30 pi (18,3 m), le
ventilateur doit être converti au mode à forte aspiration.
Coude à 90° de 3¹⁄₄" x
10" (8,3 cm x 25,4 cm)
■
Ne pas convertir au mode à forte aspiration pour les
longueurs plus courtes. Il en résulterait un bruit excessif,
une perte d’air conditionné et une déformation des
flammes sur les cuisinières à gaz.
5 pi
(1,5 m)
■
Pour convertir le ventilateur dans le cas d’une installation
dans le mode à forte aspiration, voir la section
“Installation du circuit d’évacuation par le bas”.
Coude plat de 3¹⁄₄" x
10" (8,3 cm x 25,4 cm)
12 pi
(3,7 m)
Pour calculer la longueur effective du circuit d’évacuation
nécessaire, additionner les longueurs équivalentes (en pieds ou
mètres) de tous les composants utilisés dans le système.
Bouche de décharge murale de
Composant
Conduit de diamètre de 6"
(15,2 cm)
3¹⁄₄" x 10" (8,3 cm x 25,4 cm) 0 pi
(0 m)
Coude à 45°
2,5 pi
(0,8 m)
Exemple de circuit d’évacuation
bouche de décharge murale
coude à 90˚
6 pi (1,8 m)
Coude à 90°
5 pi
(1,5 m)
2 pi
(0,6 m)
Bouche de décharge murale
de 6" (15,2 cm)
0 pi
(0 m)
Longueur maximum
= 60 pi (18,3 m)
= 5 pi (1,5 m)
= 8 pi (2,4 m)
1 coude à 90°
Raccord de 3¹⁄₄" x 10" (8,3 cm 4,5 pi
x 25,4 cm) vers 6" (15,2 cm) (1,4 m)
Section droite de 8 pi
(2,4 m)
1 bouche de décharge
murale
= 0 pi (0 m)
Raccord de 6" (15,2 cm) vers 1 pi
3¹⁄₄" x 10" (8,3 cm x 25,4 cm) (0,3 m)
Longueur totale
= 13 pi (3,9 m)
REMARQUE : On déconseille l’emploi d’un conduit flexible pour
une évacuation vers l’extérieur. Un conduit flexible peut causer
une contre-pression et des turbulences d’air, qui réduisent
considérablement la performance.
Coudé à 90° de 3¹⁄₄" x 10"
(8,3 cm x 25,4 cm) vers
6" (15,2 cm)
5 pi
(1,5 m)
28
Download from Www.Somanuals.com. All Manuals Search And Download.
Spécifications électriques
Préparation du plan de travail
(cuisinières encastrées uniquement)
Les flancs de la cuisinière encastrable s'ajustent par-dessus le
bord de la découpe du plan de travail.
AVERTISSEMENT
Si le plan de travail est plat aux arêtes carrées et la largeur de
l'ouverture est de 30" (76,2 cm), aucune préparation du plan de
travail n'est nécessaire.
Dans le cas d'un plan de travail à bords avant bombés, on devra
usiner une surface plane dans le bord moulé de ³⁄₈" (1,0 cm) à
chaque coin avant de l'ouverture.
Risque de choc électrique
Dans le cas d'un plan de travail de carrelage, il peut être
nécessaire de réduire le revêtement de ³⁄₈" (1 cm) à chaque coin
avant et/ou d'aplanir le bord avant arrondi.
Relier la cuisinière à la terre.
Le non-respect de cette instruction peut causer
un décès, un incendie ou un choc électrique.
30"
(76,2 cm)
Si l’on utilise un conducteur distinct de liaison à la terre lorsque
les codes le permettent, il est recommandé qu’un électricien
qualifié vérifie que la liaison à la terre est adéquate et la section
des fils conforme aux codes locaux.
³⁄₈"
(1,0 cm)
30 ¾"
(78,1 cm)
Vérifier que le raccordement à la source d’électricité et le calibre
des conducteurs sont conformes aux prescriptions de la plus
récente édition de la norme CSA C22.1, partie 1 – Code canadien
de l’électricité, et de tout code ou règlement local en vigueur.
Pour obtenir un exemplaire des normes des codes ci-dessus,
contacter :
Si la largeur de l'ouverture du plan de travail est supérieure à
30" (76,2 cm), ajuster la dimension ³⁄₈" (1,0 cm).
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA
Le plan de travail doit être d’aplomb. Placer un niveau sur le plan
de travail, d'abord transversalement, puis dans la profondeur. Si
le plan de travail n’est pas d'aplomb, la cuisinière ne le sera pas.
La cuisinière doit être d'aplomb pour pouvoir obtenir des
résultats de cuisson satisfaisants.
■
En cas de doute quant à la qualité de la liaison à la terre de la
cuisinière, consulter un électricien qualifié.
Puissance nominale de la
cuisinière*
Calibre du
cordon
Protection
du circuit
d’alimenta-
tion
120/240 volts 120/208 volts
A
A
8,8 - 16,5 kW
16,6 - 22,5 KW 12,6 - 18,5 KW 50
7,8 - 12,5 kW
40
40 ou 50
50
*La charge NEC calculée est inférieure à la charge totale
connectée indiquée sur la plaque signalétique.
■
■
On recommande d’utiliser un fusible ou un disjoncteur
temporisé.
Cette cuisinière est équipée d’un cordon électrique
homologué par la CSA International à brancher dans une
prise murale standard 14-50R. Veiller à ce que la prise murale
se trouve à proximité de l’emplacement définitif de la
cuisinière.
■
Ne pas utiliser de câble de rallonge.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTRUCTIONS D’INSTALLATION
Déballage de la cuisinière
Réglage des pieds de nivellement
1. Si un ajustement de la hauteur de la cuisinière est nécessaire,
utiliser une clé ou une pince pour desserrer les 4 pieds de
nivellement.
AVERTISSEMENT
Cette opération doit être effectuée alors que la cuisinière
repose sur sa partie postérieure ou qu’elle est supportée par
2 pieds après avoir été replacée en position verticale.
Risque du poids excessif
Utiliser deux ou plus de personnes pour déplacer et
installer la cuisinière.
REMARQUE : Pour placer à nouveau la cuisinière en position
verticale, placer un carton ou un panneau de fibres dur
devant la cuisinière. À l'aide d'au moins 2 personnes,
redresser la cuisinière et la placer sur le carton ou le panneau
de fibres dur.
Le non-respect de cette instruction peut causer
une blessure au dos ou d'autre blessure.
1. Ôter les matériaux d’emballage, le ruban adhésif et la
pellicule protectrice de la cuisinière. Garder la base de carton
sous la cuisinière.
AVERTISSEMENT
2. Retirer les grilles de four et le sachet de pièces de l’intérieur
du four.
3. Pour retirer la base en carton, placer la cuisinière sur sa partie
postérieure, prendre les 4 coins de protection du carton
d’emballage. Empiler l’un des coins sur un autre. Répéter
avec les 2 autres coins. Les disposer sur le plancher dans le
sens de la longueur derrière la cuisinière, à titre de support de
la cuisinière lorsque celle-ci est placée sur sa partie
postérieure.
Risque de basculement
4. À 2 personnes ou plus, saisir fermement la cuisinière et la
déposer délicatement sur sa partie postérieure, sur les coins
de protection du carton.
Un enfant ou une personne adulte peut faire basculer
la cuisinière ce qui peut causer un décès.
5. Tirer fermement sur la partie inférieure du carton pour le
Joindre la bride antibasculement au pied arrière de
la cuisinière.
retirer.
6. Utiliser une clé à molette pour desserrer les pieds de
Joindre de nouveau la bride antibasculement si la
cuisinière est déplacée.
nivellement.
7. Placer le carton ou le panneau de fibres dur devant la
cuisinière. À l’aide d’au moins 2 personnes, relever la
cuisinière et la placer sur le carton ou le panneau de fibres
dur.
Le non-respect de ces instructions peut causer un
décès ou des brûlures graves aux enfants et aux
adultes.
2. Ajuster les pieds de nivellement à la hauteur nécessaire. Les
pieds de nivellement peuvent être desserrés pour ajouter une
hauteur maximale de 1" (2,5 cm). Une longueur minimale de
³⁄₁₆" (5 mm) est nécessaire pour engager la bride
antibasculement.
REMARQUE : Si un ajustement de la hauteur est effectué
alors que la cuisinière est debout, incliner la cuisinière vers
l’arrière pour ajuster les pieds avant, puis incliner la cuisinière
vers l’avant pour ajuster les pieds arrière.
3. Lorsque la cuisinière est à la hauteur souhaitée, vérifier que
l’espace sous la cuisinière est suffisant pour loger la bride
antibasculement. Avant de faire glisser la cuisinière à son
emplacement final, vérifier qu’il sera possible de faire glisser
la bride antibasculement sous la cuisinière et sur le pied de
nivellement arrière avant l’installation de la bride
antibasculement.
30
Download from Www.Somanuals.com. All Manuals Search And Download.
Montage mural
Installation de la bride antibasculement
1. Ôter la bride antibasculement fixée par du ruban adhésif à la
pochette contenant la documentation.
2. Déterminer la méthode de montage à utiliser : au plancher ou
au mur.
A
B
Pour un plancher en pierre ou en briquetage, on peut utiliser
la méthode de montage au mur.
3. Déterminer et marquer l’axe central de l’espace à découper.
On peut installer la bride de montage du côté gauche ou droit
de la découpe. Positionner la bride de montage dans la zone
découpée de façon à ce que le bord (droit ou gauche) de la
bride se trouve à 14¹⁄₄" (36,2 cm) de l’axe central, tel
qu’illustré.
A. Vis n° 12 x 1⁵⁄₈"
B. Bride antibasculement
A
5. À l’aide d’un tournevis Phillips, monter la bride
antibasculement sur le mur ou sur le plancher avec les deux
vis n° 12 x 1⁵⁄₈" fournies.
Installation du circuit d’évacuation
par le bas
B
Déterminer la longueur équivalente du circuit
d’évacuation
A. Axe central
B. 14¹⁄₄" (36,2 cm)
Cette cuisinière est équipée d’un ventilateur à deux débits. Sa
configuration d’usine concerne les installations à faible
aspiration. Si la longueur équivalente du système d’évacuation
par le bas dépasse 30 pieds (9,1 m), le moteur du ventilateur
d’aspiration doit être converti au mode à forte aspiration pour
une meilleure performance. Voir “Calcul de la longueur effective
du circuit d’évacuation”.
4. Percer deux trous de ¹⁄₈" (3,0 mm) qui correspondent aux
trous de la bride selon la méthode de montage déterminée.
Voir ci-dessous.
Montage au plancher
A
B
Pour effectuer la conversion :
Retirer doucement l’anneau de réduction à ressort de l’entrée du
ventilateur en appuyant sur l’un des trois ressorts.
B
A
A. Vis n° 12 x 1⁵⁄₈"
B. Bride antibasculement
A. Anneau de réduction
B. Ressort
Déterminer la méthode d’évacuation à utiliser : par le plancher, le
mur arrière, le côté droit ou le côté gauche. Consulter la section
se rapportant à votre type d’évacuation.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Placer le ventilateur dans l’ouverture entre les placards.
Raccorder le circuit d'évacuation à la sortie du ventilateur à
l’aide d’une bride pour conduit.
Évacuation par le mur arrière
1. Tracer sur le mur l’axe central de l’ouverture entre les
Vue de dessus
placards.
E
C
D
A
B
2. Vérifier l’absence d’obstruction avant de tracer
l’emplacement du trou d’évacuation. Tracer une ligne
horizontale à 8³⁄₁₆" (20,8 cm) du sol. Tracer une ligne verticale
à droite de l’axe central entre les placards, distante de
2¼" (7,9 cm) au maximum de l’axe central.
A. 18¾" (47,6 cm) maximum entre l’ouverture
entre les placards et le mur arrière
B. Entrée
C. Circuit d’évacuation
D. Bride pour conduit
E. Évacuation murale
A
5. Fixer le ventilateur au sol avec les 4 vis n° 8 x ¾" à tête
hexagonale fournies.
Vue de dessus
B
A. 2¼" (7,9 cm) maximum à droite
de l’axe central
B. 8³⁄₁₆" (20,8 cm) du sol
3. Tracer et découper un trou de 6¼" (15,8 cm) de diamètre.
A
6. Voir la section “Raccordement électrique”.
A. 6¼" (15,8 cm)
32
Download from Www.Somanuals.com. All Manuals Search And Download.
Vue de dessus
Évacuation par le plancher
1. Tracer au sol l’axe central de l’ouverture entre les placards.
B
C
D
A
E
F
G
I
H
2. Placer le gabarit sur le sol à 2¼" (5,7 cm) du mur arrière en
faisant correspondre son axe central avec l’axe central tracé
au sol.
A. 9" (22,8 cm)
F. 12½" (31,7 cm)
G. 18¾" (47,6 cm)
H. 1½" (3,8 cm)
I. 3½" (8,9 cm)
3. Déterminer la position correcte du trou d’évacuation en
B. 3¹⁄₈" (7,9 cm)
C. 8³⁄₈" (21,3 cm)
D. 6³⁄₈" (16,2 cm)
E. 2¼" (5,7 cm)
fonction des obstructions (solives) dans le plancher.
Le trou peut être découpé partout dans les limites de l’une
des zones hachurées.
Option 1 : En cas d’utilisation de la zone hachurée arrière (la
plus grande), l’entrée du ventilateur doit faire face au côté
gauche, comme illustré sur le gabarit.
4. Tracer et découper un trou de 6¼" (15,8 cm) de diamètre
(option 1 illustrée).
Option 2 : En cas d’utilisation de la zone hachurée avant (la
plus petite), l’entrée du ventilateur doit faire face au mur
arrière.
Vue de dessus
Option 1
Option 2
B
B
A
A
A. Option 1
B. Option 2
A
5. Placer le moteur du ventilateur dans l’ouverture entre les
placards et le fixer au sol.
Vue de dessus
B
Option 1
Option 2
A. Entrée depuis la cuisinière
B. Sortie d’évacuation
B
REMARQUE : Si le gabarit est égaré, les mesures suivantes
peuvent servir à déterminer l’emplacement du trou
d’évacuation.
A
A
B
A. Entrée depuis la
cuisinière
B. Sortie d’évacuation
33
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Raccorder le circuit d’évacuation à la sortie du moteur du
ventilateur (option 1 illustrée) avec les 4 vis n° 8 x ¾" à tête
hexagonale fournies.
3. Tracer et découper une ouverture de 14" x 11" (35,6 x
27,9 cm) dans le plancher du placard portant la découpe du
trou d’évacuation.
Vue de dessus
A
B
A
B
C
D
A. Entrée
B. Bride pour conduit
C. Plancher
D. Circuit d’évacuation
A. 11" (27,9 cm) à partir de l’avant du placard
B. 14" (35,6 cm) à partir du côté gauche du placard
4. Dévisser les quatre écrous de blocage du côté moteur du
7. Voir la section “Raccordement électrique”.
ventilateur et retirer la bride.
Vue du ventilateur côté moteur
Évacuation par la gauche ou par la droite
1. Repérer sur le côté du placard l’emplacement du trou
A
d’évacuation à droite ou à gauche.
A
B
A. Connecteur électrique
A. 31³⁄₁₆" (79,2 cm) jusqu’en haut du placard
B. 18" (45,7 cm) depuis le mur arrière
5. Soulever le moteur et le faire pivoter de 180° pour replacer la
connexion électrique.
2. Tracer et découper un trou de 5½" (13,9 cm) de diamètre sur
le placard du côté souhaité.
A
A
A. Connecteur électrique
6. Faire pivoter le support de 180° et le fixer avec les 4 écrous
A. Trou de 5½" (13,9 cm) de diamètre
de blocage.
34
Download from Www.Somanuals.com. All Manuals Search And Download.
7. Dévisser le support de l’autre côté du ventilateur, le faire
pivoter de 180° et le fixer avec les 4 écrous de blocage.
Raccordement de la cuisinière au circuit
d’évacuation par le bas
1. Raccorder le conduit flexible (fourni) à l’entrée du ventilateur
à l’aide d’une bride pour conduit.
8. Placer 2 cales en bois et les fixer au sol.
Vue de dessus
B
A
C
B
A. Conduit flexible d’entrée
B. Bride pour conduit
A
D
D
2. Vérifier la hauteur du plan de travail pour s’assurer que la
cuisinière passe dessous. Régler les pieds de nivellement le
cas échéant.
3. Déposer le panneau d’accès en le tirant vers le haut des deux
mains de chaque côté et en le soulevant pour l'extraire.
4. Déplacer la cuisinière près de l’ouverture d’encastrement.
A. Cales de 2" x 4" (5 x 10,2 cm) en bois
B. 2⁷⁄₉" (7.3 cm) entre l’arrière du mur et le bord de la
5. Brancher la cuisinière à une prise reliée à la terre (en cas
cale en bois
d’utilisation d’un cordon d’alimentation).
C. 8¾" (22,2 cm)
D. 2⁵⁄₁₆" (5,8 cm) entre l’axe central de l’ouverture et la
cale en bois
6. Brancher le connecteur électrique de la cuisinière au
ventilateur d’évacuation par le bas.
9. Fixer le ventilateur aux cales en bois avec les 4 vis n° 8 x ¾" à
tête hexagonale fournies.
REMARQUE : Le circuit d’évacuation sera raccordé une fois
la cuisinière à son emplacement final. Voir la section
“Raccordement de la cuisinière au circuit d’évacuation par le
bas”.
A
Vue de dessus
B
C
B
A
A. Cordon d’alimentation (sur certaines installations)
B. Connecteur électrique de la cuisinière au ventilateur
A. Cales en bois
B. Bride de montage
C. Ventilateur
35
Download from Www.Somanuals.com. All Manuals Search And Download.
7. Retirer le carton ou le panneau de fibre dur de sous la
cuisinière. À deux personnes ou plus, déplacer doucement la
cuisinière à son emplacement final.
10. Selon votre installation, raccorder le conduit flexible d’entrée
du ventilateur à la cuisinière au moyen d’une bride pour
conduit.
Évacuation par le mur
Vue de dessus
B
8. Vérifier que la bride antibasculement est installée et que les
câbles électriques ne sont pas pincés. Au moyen d’une
torche électrique, inspecter le dessous de la cuisinière.
A
C
■
Vérifier que la bride antibasculement est bien fixée au
plancher ou au mur.
A. Cuisinière
B. Sortie d’évacuation murale
C. Bride pour conduit
■
Faire glisser de nouveau la cuisinière de façon à ce que le
pied arrière de la cuisinière se trouve sous la bride
antibasculement.
Évacuation par le plancher
Vue de dessus
B
9. Régler l’aplomb de la cuisinière.
a.) Placer la grille dans le four.
b.) Placer un niveau sur la grille et contrôler l’aplomb de la
cuisinière, d’abord transversalement, puis dans le sens
avant/arrière.
A
C
A. Cuisinière
B. Sortie d’évacuation par le plancher
C. Bride pour conduit
c.) Si la cuisinière n’est pas d’aplomb, la tirer de nouveau
pour que le pied de nivellement arrière se dégage de la
bride antibasculement.
d.) Utiliser une pince multiprise pour régler les pieds de
nivellement vers le haut ou vers le bas jusqu’à ce que la
cuisinière soit d’aplomb.
e.) Repousser la cuisinière pour la remettre en place.
f.) Vérifier que le pied de nivellement arrière est engagé dans
la bride antibasculement.
REMARQUE : La cuisinière doit être d’aplomb pour que les
résultats de cuisson au four soient satisfaisants.
36
Download from Www.Somanuals.com. All Manuals Search And Download.
Évacuation latérale (évacuation par la gauche illustrée)
Achever l’installation
Raccorder le conduit d’évacuation flexible à la cuisinière et le
circuit d’évacuation à la sortie du ventilateur.
1. Vérifier que toutes les pièces sont maintenant installées. S’il
reste une pièce, passer en revue les différentes étapes pour
découvrir laquelle aurait été oubliée.
Vue de dessus
2. Vérifier la présence de tous les outils.
A
3. Éliminer/recycler les matériaux d’emballage.
4. Vérifier que la cuisinière est d’aplomb. Voir “Raccordement
de la cuisinière au circuit d’évacuation par le bas”.
5. Utiliser une solution d’eau tiède et de nettoyant ménager
doux pour éliminer tout résidu de cire laissé par les matériaux
d’emballage. Sécher parfaitement avec un linge doux. Pour
plus d’informations, lire la section “Entretien de la cuisinière”
dans le Guide d’utilisation et d’entretien.
E
6. Lire la section “Utilisation de la cuisinière” dans le Guide
d’utilisation et d’entretien.
7. Mettre en marche les brûleurs de surface et le four. Pour des
instructions spécifiques concernant l’utilisation de la
cuisinière, consulter le Guide d’utilisation et d’entretien.
D
C
Si la cuisinière ne fonctionne pas, contrôler ce qui suit :
B
■
Les fusibles du domicile sont intacts et serrés ; le disjoncteur
n’est pas déclenché.
A. Conduit flexible vers la
cuisinière
B. Bride pour conduit
C. Cuisinière
D. Circuit d’évacuation
E. Sortie d’évacuation
latérale
■
■
■
La cuisinière est branchée sur une prise électrique.
La prise de courant est correctement alimentée.
11. Replacer le panneau d’accès.
Consulter la section “Dépannage” dans le Guide d’utilisation
et d’entretien.
Après 5 minutes de fonctionnement de la cuisinière, vérifier la
chaleur. Si la cuisinière est froide, l’éteindre et contacter un
technicien qualifié.
8. Utiliser la fiche de test du débit fournie avec votre cuisinière
pour contrôler la circulation d’air (voir la fiche pour obtenir
des instructions étape par étape).
12. Insérer le filtre d’évacuation par le bas et placer la plaque de
décharge par-dessus l’ouverture.
B
Si la circulation d’air est insuffisante, consulter les sections
“Exigences concernant l’évacuation” et “Méthodes
d’évacuation”.
A
Si vous avez besoin d’assistance ou de service :
Consulter la section “Assistance ou service” du Guide
d’utilisation et d’entretien ou contacter le marchand chez qui
vous avez acheté votre cuisinière.
A. Filtre
B. Grille
13. Reconnecter la source de courant électrique.
37
Download from Www.Somanuals.com. All Manuals Search And Download.
Déplacement de la cuisinière
7. Vérifier que la cuisinière est d’aplomb.
8. Reconnecter la cuisinière au circuit d’évacuation par le bas.
AVERTISSEMENT
Pour les cuisinières avec câblage direct :
AVERTISSEMENT
Risque de basculement
Un enfant ou une personne adulte peut faire basculer
la cuisinière ce qui peut causer un décès.
Risque de choc électrique
Joindre la bride antibasculement au pied arrière de
la cuisinière.
Déconnecter la source de courant électrique avant
l'entretien.
Joindre de nouveau la bride antibasculement si la
cuisinière est déplacée.
Replacer pièces et panneaux avant de faire la remise
en marche.
Le non-respect de ces instructions peut causer un
décès ou des brûlures graves aux enfants et aux
adultes.
Le non-respect de ces instructions peut causer
un décès ou un choc électrique.
Lorsqu’on déplace la cuisinière, la faire glisser sur une planche
de carton ou en matériau dur pour éviter d’endommager le
revêtement du sol.
1. Déconnecter la source de courant électrique.
2. Déconnecter la cuisinière du circuit d’évacuation par le bas.
3. Faire glisser la cuisinière vers l’avant.
Si le déplacement de la cuisinière est nécessaire pour le
nettoyage ou l’entretien :
4. Effectuer le nettoyage ou l’entretien.
5. Retirer le panneau d’accès et inspecter à l’aide d’une lampe
de poche le dessous de la cuisinière pour vérifier que la bride
antibasculement est bien installée.
Cuisinières alimentées par cordon d’alimentation :
1. Déconnecter la cuisinière du circuit d’évacuation par le bas.
2. Faire glisser la cuisinière vers l’avant.
■
Vérifier que la bride antibasculement est bien fixée au
plancher ou au mur.
3. Débrancher le cordon d’alimentation électrique.
4. Effectuer le nettoyage ou l’entretien.
5. Brancher le cordon d’alimentation électrique.
■
Faire glisser de nouveau la cuisinière de façon à ce que le
pied arrière de la cuisinière se trouve sous la bride
antibasculement.
6. Retirer le panneau d’accès et inspecter à l’aide d’une lampe
de poche le dessous de la cuisinière pour vérifier que la bride
antibasculement est bien installée.
■
Vérifier que la bride antibasculement est bien fixée au
plancher ou au mur.
■
Faire glisser de nouveau la cuisinière de façon à ce que le
pied arrière de la cuisinière se trouve sous la bride
antibasculement.
6. Vérifier que la cuisinière est d’aplomb.
7. Reconnecter la cuisinière au circuit d’évacuation par le bas.
8. Reconnecter la source de courant électrique.
38
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes
39
Download from Www.Somanuals.com. All Manuals Search And Download.
W10253462A
© 2009.
5/09
Printed in U.S.A.
Imprimé aux É.-U.
All rights reserved.
Tous droits réservés.