Jacuzzi Swimming Pool Vacuum E 1451 User Manual

Jacuzzi  
®
Magnum, RC, LR, Cygnet  
E-1451  
Owner’s Manual  
6. WARNING – (For cord & plug connected units).  
To reduce the risk of electrical shock do not use an  
extension cord to connect unit to electrical supply;  
provide a properly located outlet.  
Before installation, be sure to read all instructions  
and warnings carefully.  
Refer to product dataplate(s) for additional operating  
instruction and specifications.  
7. CAUTION – (For pumps with a 25 ft. (7.62m cord).  
This pump is for use with storable pools only. Do  
not use with permanently installed pools. A storable  
pool is constructed so that it may be readily  
disassembled for storage and reassembled to its  
original integrity. A permanently installed pool is  
constructed in or on the ground or in a building such  
that it cannot be readily disassembled for storage.  
8. CAUTION – (For pumps with/without 3ft. (.91m  
cord). This pump is for use with permanently  
installed pools and may also be used with hot tubs  
and spas if so marked. Do not use with storable  
pools. A permanently installed pool is constructed  
in or on the ground or in a building such that it  
cannot be readily disassembled for storage. A  
storable pool is constructed so that it may be readily  
disassembled for storage and reassembled to its  
original integrity.  
Inspection  
Examine the equipment when received. Notify your  
dealer or carrier of any damage or missing parts. Verify  
that equipment is of size and model specified.  
Important Safety Instructions  
When installing and using this electrical equipment,  
basic safety precations should always be followed,  
including the following:  
1. READ AND FOLLOW ALL INSTRUCTIONS.  
2. WARNING – To reduce risk of injury, do not permit  
children to use this product unless they are closely  
supervised at all times.  
3. WARNING – (For cord & plug connected units). Risk  
of Electrical Shock. Connect only to a grounding type  
receptacle protected by a ground-fault circuit-  
interrupter (GFCI). Contact a qualified electrician if  
you cannot verify that the receptacle is protected by a  
GFCI.  
9. WARNING – (For hot tub and spa pumps). Do not  
install within an outer enclosure or beneath the skirt  
of the hot tub or spa, unless so marked.  
10. SAVE THESE INSTRUCTIONS!  
4. WARNING – (For cord & plug connected units). Do  
not bury cord. Locate cord to minimize abuse from  
lawn mowers, hedge trimmers and other equipment.  
Installation Location  
Locate pump as close to pool/spa as possible,  
preferably in a dry, well ventilated area away from direct  
5. WARNING – (For cord & plug connected units). To sunlight. It should be on a hard, level surface. Give  
reduce the risk of electric shock, replace damaged  
cord immediately.  
consideration to:  
should be on a hard, level surface. Give consideration to:  
the pump discharge. The valves are essential for pump  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS DIAGRAM FOR MAGNUM, MAGMUN PLUS, & MAGNUM FORCE MODELS  
FIG. NO. PART NO.  
DESCRIPTION  
1
2
3
42-2828-06-R  
39-2579-02-R  
47-0358-03-R  
47-0434-01  
Cover retainer  
Strainer cover 7/88  
O-Ring – Units after 7/89  
O-Ring 5-5/8 x 6-1/8 x ¼ - Units prior 7/89  
Strainer basket with Flapper  
Flapper  
Magnum body strainer 2” with plugs  
Magnum Force body  
4
4a  
5
5a  
6
16-1097-04-R  
43-3036-01-R  
03-0856-02-R  
03-2009-04-R  
47-0112-00-R  
31-1609-06-R  
12-1069-02-R  
12-1124-05-R  
12-1126-03-R  
14-4231-07-R  
47-0232-54-R  
14-4206-08-R  
06-0157-05-R  
06-0165-05-R  
06-0167-03-R  
10-1462-07-R  
05-3800-01-R  
05-3818-01-R  
05-3819-00-R  
05-3820-07-R  
05-3854-06-R  
05-3855-05-R  
10-1502-09  
Plug O-Ring (2req’d)  
7
9
¼” plug with 47011200 O-Ring  
Base motor support assembly 2/88  
Motor support  
Motor base  
Dowel pin ¼ x 1-¼ SS 4/89  
Square ring  
Hex wash. hd. A8 – 16 x 1¼ SS (2 req’d)  
Diffuser, ½ HP full rate & ¾ HP uprate  
Diffuser, 5-¼ fit. 1-½ – 3 HP full rate & 2 HP uprate  
Diffuser, 4.875 fit. ¾ - 1 HP full rate 1 – 1-½ HP uprate  
Eye seal  
Impeller, ½ HP full & ¾ HP uprate 4-3/16” Dia.  
2 HP, full rate 5-3/16” Dia.  
1-½ HP full rate 2 HP uprate 5-1/8” Dia.  
3 HP full rate 5-1/8” Dia.  
1 HP full rate 1-½” HP uprate 4-¾” Dia.  
¾ HP full rate 1 HP uprate 4-¾” Dia.  
Shaft seal (replaces 10139004)  
O-Ring  
Seal housing, 5-¼ fit. 1-½ – 3 HP full rate, 2 HP update  
Seal housing, 4-9/16 fit. ½ HP full rate, ¾ HP uprate  
Seal housing, 4-7/8 fit. ¾ - 1 HP full rate 1-½ HP uprate  
Motor housing bracket  
PL hex capscrew 3/8 – 16 x 7/8 (4 req’d)  
Pump mounting nut 2/88  
Mounting nut rachet  
Motor, see chart pg. 57 for selection  
Motor support kit GE to Century  
Case/Base assembly  
9a  
9b  
10  
11  
*12  
13  
14  
15  
16  
17  
18  
47-0364-47-R  
02-1392-02-R  
02-1366-04-R  
02-1393-01-R  
02-1368-02-R  
14-1293-24-R  
42-2886-05-R  
42-2867-08-R  
19  
20  
21  
22  
23  
24  
25  
42-3555-03  
24-0138-07  
NOTE: 3 each required for diffuser 06-0165-05-R. 5 each required for diffuser 06-0167-03-R  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS FOR MODELS RC, URC, RTC, URTC  
FIG. NO. PART NO.  
DESCRIPTION  
1
3
4
5
6
7
8
9
03-2001-02-R  
31-1609-06-R  
47-0466-02-R  
14-4244-02-R  
12-1036-02-R  
47-0462-06-R  
14-4206-08-R  
06-0157-05-R  
06-0163-07-R  
06-0164-06-R  
06-0166-04-R  
10-1462-07-R  
10-1463-14-R  
10-1464-13-R  
05-3806-05-R  
05-3800-01-R  
05-3801-00-R  
05-3802-09-R  
05-3803-08-R  
05-3805-06-R  
05-3852-08-R  
10-1389-07-R  
02-1389-07-R  
02-1351-01-R  
02-1610-08-R  
14-1266-35-R  
14-1293-24-R  
2” Case/Flange Assy.  
Drain plug with 47-0112-00 O-Ring  
Square ring  
Base fastener kit 2” 4/90  
Base assembly (with Fastn. Kit #5)  
Square ring  
Diffuser, bolt 8-16 x 1 ¼ SS (2 Req’d)  
Diffuser, ½-1 HP full rate & 1½ HP uprate  
Diffuser, 1½ -2 HP full rate & 2 HP uprate  
Diffuser, 3 HP full rate  
Diffuser, “New” 2HP full rate  
10  
11  
Eye seal, ½-1 HP full rate & 1½ HP uprate  
Eye seal, 1½-2 HP full rate & 2 HP uprate  
Eye seal, 3 HP full rate eff.  
Impeller, 5URC UR. 3-5/8” dia.  
Impeller, ½ HP full rate & ¾ HP uprate 4-3/16” dia.  
Impeller, ¾ HP full rate & 1 HP uprate 4-1/16” dia.  
Impeller, 1 HP full rate & 1½ HP uprate 4-25/64” dia.  
Impeller, 1½ HP full rate & 2 HP uprate 4-9/16” dia.  
Impeller, 3 HP full rate 4¾” dia.  
Impeller “new” 2 HP full rate 5” dia.  
Shaft seal  
Bracket, 4½” fit ½ - 1 HP full rate & 1½ HP uprate  
Bracket,4-29/32” fit 1½ - 3 HP full rate & 2 HP uprate  
Bracket, 5-5/32” fit “new” 2 HP full rate  
Bracket bolt ¼ - 20 x ¾ SS (8 req’d)  
Motor bolt 3/8-16 x 7/8 SS (4 req’d)  
Motor  
12  
13  
14  
15  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS DIAGRAM FOR LR, LR9 LRX, LRT, LR3, LR6, LR25, LVL  
FIG. NO. PART NO.  
DESCRIPTION  
1
2
3
4
42-1678-09-R  
39-0753-04-R  
47-0352-41-R  
16-0240-02-R  
16-1052-15-R  
16-0307-02-R  
03-1957-24-R  
16-0985-01-R  
47-0258-53-R  
10-1462-07-R  
05-3760-09-R  
05-3759-02-R  
05-3821-06-R  
05-3853-07-R  
10-0002-06-R  
02-1388-08-R  
14-3970-04-R  
14-4238-00-R  
14-3971-03-R  
14-4239-09-R  
31-1609-06-R  
23-4856-00-R  
23-4718-08-R  
23-4863-01-R  
12-1109-04-R  
Strainer nut  
Strainer cover  
O-Ring  
Basket LR  
LVL Strainer Basket  
5
Strainer case assy. With plugs LR  
Case assy. With 1 plug and O-Ring LVL  
Strainer case assy. 9.00 disch.  
Square ring 6 x 1/8 x 1/8  
5a  
6
7
Seal ring  
8
Impeller for 5LVL, 5LR, ½ HP, 3.45D, #9838  
Impeller for 7LVL, 7LR, ¾ HP, 3.73D, #9838  
Impeller for 1LVL, 1LR, 1HP, 4.0D, #9838  
Impeller for 15LVL, 16LR, 1½ HP, 4.22D, #1135D  
Mechanical seal  
9
10  
11  
Bracket  
PL. Hex 10 – 24 x 1¼ (6 req’d) LR  
SS Hex 10 – 24 x 1¼ (6 req’d) LRDV & LVL  
PL. Hex nut 10 – 24 (6 req’d) LR  
SS Hex nut 10 – 24 (6 req’d) LRDV & LVL  
Plug with 47-0112-00 O-Ring  
Cord with plug 6ft. F/LRX, LR6, 6ft. with 3 prong grounded plug  
Cord with plug 25 ft. F/LR25  
Cord with plug #12-3 115v 3ft. all LR3, twist-lock plu  
LVL/LTVL with 8587-4105 motor support  
Motor  
12  
13  
15  
16  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS DIAGRAM FOR CYGNET  
FIG. NO. PART NO.  
DESCRIPTION  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
42-1678-09-R  
39-0753-04-R  
47-0352-41-R  
16-1052-15-R  
16-1105-04-R  
47-0112-00-R  
31-1609-06-R  
14-4231-07-R  
14-1301-02-R  
14-0722-01-R  
14-0727-06-R  
14-4206-08-R  
06-0150-07-R  
10-1462-07-R  
05-3936-08-R  
05-3937-07-R  
05-3939-05-R  
05-3940-02-R  
10-0002-06  
Strainer RingLok  
Strainer cover  
Strainer O-Ring 4-7/8 ID x 3/16 THK  
Strainer Basket  
Case with 2” plugs  
Plug O-Ring (2)  
Plug with O-Ring (2)  
Base dowel pin  
SS Bolt 3/8-16x2 - ½ (4)  
SS Lock washer – 3/8 (4)  
SS Nut 3/8-16 (4)  
Diffuser screws 8 – 16 x 1¼” (2)  
Diffuser  
Eye seal  
IMP ¾ HP  
IMP 1 HP  
IMP 1½ HP  
IMP 2 HP  
16  
17  
18  
19  
Mechanical seal  
O-Ring 6” ID x 3/16 THK  
Seal plate  
Motor ¾ HP  
Motor 1 HP  
Motor 1½ HP  
Motor 2 HP  
Base assy.  
47-0361-48-R  
11-1520-00-R  
90-1069-15-R  
90-1069-23-R  
90-1069-31-R  
90-1069-49-R  
12-1135-02-R  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Motor windings burned out.  
4. Defective starting switch inside single-phase motor  
5. Disconnected or defective wiring  
6. Low voltage  
Winterizing  
Consult your dealer for advice on winterizing your  
equipment if freezing temperatures occur in your locality.  
His knowledge of your equipment makes him the best  
qualified source of information. Follow his  
recommendations, and if these include draining the filter  
system, proceed as follows:  
MOTOR DOES NOT REACH FULL SPEED  
1. Low voltage  
2. 2 speed model set on low speed  
3. Motor windings connected for wrong voltage on  
dual voltage model.  
1. If your system does not contain a filter, proceed to  
step2.  
A. For sand filters: BACKWASH for 3 to 5  
minutes and set dial valve to WINTERIZE.  
B. For cartridge filters: Clean the filter element and  
store in a dry place.  
MOTOR OVERHEATS (Protect trips)  
1. Low voltage  
2. Motor windings connected for wrong voltage on  
dual voltage model.  
2. Drain system by loosening drain plugs (drain plugs  
will drain without completely removing the plug  
from unit) and/or removing pipe caps.  
3. Inadequate ventilation  
PUMP DELIVERS NO WATER  
1. Pump is not primed  
2. Closed valve in suction or discharge line  
3. Leakage or air into suction system  
4. Impeller clogged  
Water Chemistry  
A proper and consistent use of chemicals is  
necessary to maintain clean, sanitary water, prevent a  
spread of germ infection and control the growth of algae  
which can spoil the appearance and enjoyment of your  
pool or spa.  
Chlorine is the most commonly used chemical to  
provide clean, sanitary water. Either dry or liquid chlorine  
(calcium or sodium hypochlorite) can be used which  
should be added daily as it is dissipated by dirt and germs  
as well as be the sun and wind.  
It is also important that the correct level of acidity or  
alkalinity of the pool water be maintained. This is the pH  
of your pool with pH 7.0 being neutral. Readings above  
7.0 are alkaline and below are acid. A desirable range is  
7.2 – 7.4.  
LOW PUMP CAPACITY  
1. Valve in suction or discharge line partly closed  
2. Suction or discharge line partly plugged  
3. Suction or discharge line too small  
4. Pump running at reduced speed (see above)  
5. Plugged basket in skimmer or hair and lint strainer  
6. Dirty filter  
7. Impeller clogged  
8. Wrong rotation (3 phase only)  
LOW PUMP PRESSURE  
1. Pump running at reduced speed (see above)  
2. Wrong rotation (3 phase only)  
Pump Maintenance  
1. Motors are self-lubricating – no lubrication required.  
2. Clean hair & lint strainer if you have a strainer body  
pump.  
3. Discharge valve or inlet fittings closed too much  
3. Visually inspect motor for blockage of air vents on  
motor shell. Remove any debris after breaker off.  
4. Shaft seals may become worn and must be replaced if  
leakage is observed.  
HIGH PUMP PRESSURE  
1. Discharge valve or inlet fittings closed too much  
2. Return lines too small  
3. Dirty filters  
Cleaning  
NOISY PUMP AND MOTOR  
1. Plugged basket in skimmer or hair in lint strainer  
2. Worn motor bearings  
3. Valve in suction line partly closed  
4. Suction line partly plugged  
5. Vacuum hose plugged or too small  
6. Pump not supported properly  
Switch power off. Close valves in suction and return  
line. Unscrew strainer Ring-Lok counterclockwise and  
remove the strainer cover from hair and lint strainer and lift  
out strainer basket. Clean and replace the basket. Take care  
to seat basket properly. Clean O-Ring and re-lubricate with  
petroleum jelly if necessary. Clean O-Ring seats on cover  
and strainer. Refit cover and strainer – hand tighten only –  
and open valves. Put pump back into operation.  
Caution: Do not retighten strainer during operation.  
LEAKAGE OF WATER AT SHAFT  
1. Shaft seal requires replacement  
Service & Repair Parts  
Refer all service to your local dealer as his knowledge  
of your equipment makes him the best qualified source of  
information. Order all repair parts through your dealer. Give  
the following information when ordering repair parts:  
1. Unit nameplate data.  
AIR BUBBLES AT INLEY FITTINGS  
1. Leakage air into suction line at connections or valve  
stem  
2. Cover gasket of hair and lint strainer needs cleaning  
3. Restriction in suction line  
2. Description of part.  
4. Low water level in pool  
Trouble Shooting  
MOTOR DOES NOT START  
1. Disconnect switch or circuit breaker in OFF position.  
2. Fuses blown or thermal overload open.  
Locked motor shaft.  
NOTE: If the recommendations in the Trouble  
Shooting portion of this manual do not solve your  
particular problem(s), please contact your local dealer  
for service.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
JACUZZI BROS.  
®
Division of Jacuzzi INC.  
LIMITED WARRANTY  
Jacuzzi Bros. Division (JBD) warrants its new products to be free of defects in materials  
and workmanship for a period of 1 year from date of installation or 3 years from date of  
manufacture, whichever comes first. Jacuzzi Bros. Also provides additional warranty coverage on  
specific products as specified herein.  
Magnum Plus and Magnum Force pumps (excluding pump seal, o-rings, square rings,  
strainer basket, and lid) are warranted to be free of defects in material and workmanship for a  
period of 3 years from date of installation or 4 years from date of manufacture, whichever comes  
first.  
JBD’s warranty obligation with regard to equipment not of its own manufacture is limited  
to the warranty actually extended to JBD by its suppliers. Performance of equipment is further  
warranted to be accordance with stated ratings when properly installed under normal conditions  
of operation.  
This warranty extends only to the original retail purchaser and only during the time in  
which the original retail purchaser occupies the site where the product was originally installed.  
Requests for service under this warranty shall be made by contacting the installing JBD  
dealer (point of purchase) as soon as possible after the discovery of any alleged defect/ JBD will  
subsequently take corrective action as promptly as reasonably possible.  
JBD at its discretion may replace or repair any product that fails under this  
warranty after inspection by an authorized company representative or after JBD has received the  
product at our factory. Replacement or repair cannot be made until after the product is inspected.  
All charge or expenses for freight to and from the factory, removal and reinstallation of the  
product, or installation of a replacement product are the responsibility of the purchaser.  
THIS WARRANTY SUPERSEDES ANY WARRANTY NOT DATED OR BEARING  
AN EARLIER DATE. ANY IMPLIED WARRANTIES WHICH THE PURCHASER MAY  
HAVE, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR  
PURPOSE, SHALL NOT EXTEND BEYOND THE APPLICABLE WARRANTY PERIOD.  
Some states do not allow limitations on how long an implied warranty lasts, so the above  
limitation may not apply to you. IN NO EVENT SHALL JBD BE LIABLE FOR INCIDENTAL  
OR CONSEQUENTAL DAMAGES. Some states do not allow the exclusion or limitation of  
incidental or consequential damages, so the above may not apply to you.  
This warranty does not apply to any product which has been subjected to negligence,  
alteration, accident, abuse, misuse, improper installation, vandalism, civil disturbances, or acts of  
God. The only warranties authorized by JBD does not authorize other persons to extend any  
warranties with respect to its products, nor will JBD assume liability for any unauthorized  
warranties made in connection with the sale of its product.  
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY  
ALSO HAVE OTHER RIGHTS WHICH MAY VARY FROM STATE TO STATE.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Indesit Washer IWC 61251 User Manual
InFocus Home Theater System IN5120 User Manual
InFocus Projector DP9295 User Manual
Ingersoll Rand Heat Pump LM2305A XX User Manual
Intel Computer Hardware ADE 9040 User Manual
IOGear Switch GCS1712 User Manual
Jettech Metal Products Dishwasher X 32 User Manual
JVC Home Theater System LVT1002 001B User Manual
Kenwood Mixer KM200 User Manual
Kenwood Weather Radio TM 732A User Manual