Jacuzzi Outdoor Shower SEDONA User Manual

SEDONA™  
Steam & Shower Base  
INSTALLATION/OPERATING INSTRUCTIONS  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONTENTS  
Specifications _________________________________________________________________________ 2  
Roughing-in Reference _________________________________________________________________ 2  
Framing and Support ___________________________________________________________________ 3  
Steam Enclosure _____________________________________________________________________ 4  
SteamPro™ Drain Down Configurations ___________________________________________________ 4  
Digital Control & Temperature Sensor Rough-in _____________________________________________ 5  
Drain Information ______________________________________________________________________ 6  
Plumbing and Water Supply ______________________________________________________________ 6  
Electrical Connections___________________________________________________________________ 6  
Digital Controller Mounting _______________________________________________________________ 7  
Temperature Sensor Mounting ____________________________________________________________ 8  
Flange Mounting _______________________________________________________________________ 8  
Finish Materials ______________________________________________________________________ 8-9  
Service Access _______________________________________________________________________ 9  
Operation ____________________________________________________________________________ 10  
Maintenance __________________________________________________________________________ 10  
Troubleshooting _______________________________________________________________________ 11-12  
SteamPro™ Wiring Diagram ______________________________________________________________ 13  
SteamPro™ Warranty __________________________________________________________________ 15-16  
Base Warranty ________________________________________________________________________ 17-18  
Save These Instructions for Future Use.  
Owner's Record  
Date Purchased ____________________________________________________________  
Purchased From ____________________________________________________________  
Installed By ________________________________________________________________  
Serial Number (Base) ________________________________________________________  
Serial Number (Steam Generator) ______________________________________________  
Model ____________________________________________________________________  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Important: Read complete instructions before beginning installation.  
Each shower base is shipped with a drain and stainless steel strainer  
Remove the shower base from the carton. Do not destroy the shipping carton until after satisfactory  
inspection of the product.  
Immediately upon receipt, inspect the base before installing. Should inspection reveal any damage or defect in the  
finish, do not install the base. Damage or defect to the finish claimed after the base is installed is excluded from the  
warranty. Jacuzzi Whirlpool Bath’s responsibility for shipping damage ceases upon delivery of the products in good  
order to the carrier. Refer any claims for damage to the carrier. For definitions of warranty coverage and limitations,  
refer to the published warranty information packaged with the product. Jacuzzi Whirlpool Bath is not responsible for  
any defect that could have been discovered, repaired, or avoided by following this inspection and testing procedure.  
Plan the installation in relation to the finished wall surfaces. Take into account the dimensions of both the shower  
base and the shower door enclosure to be used with it.  
NOTE: Damage or defects which could have been discovered and repaired prior to installation and which are claimed  
after final installation of the product are excluded from our warranty.  
SPECIFICATIONS  
PRODUCT  
WEIGHT  
TOTAL WEIGHT/  
FLOOR LOADING  
DIMENSIONS  
ELECTRICAL  
60"  
32"  
(1524 mm) L  
( 813 mm) W  
110 lb  
(50 kg)  
*230 VAC, 60 Hz.  
40 AMP, 3 Wire  
Requires a  
Dedicated Separate  
Circuit.  
310 lbs  
(141 kg)  
/23 lb/sq. ft.  
(112 kg/sq. m)  
18-5/8" ( 473 mm) H  
*SteamPro supplied with NEMA 6-50P plug. NEMA 6-50R receptacle required.  
Product specifications are subject to change without notice.  
60"  
LOCATION FOR  
INCOMING WATER  
SUPPLY LINE TO  
RECEPTACLE  
STEAMER (INSTALLED  
AND PREPLUMBED  
WITH 3/8" COPPER  
TUBINGTO STEAM  
GENERATOR WITH  
SHUT OFF VALVE)  
LOCATION  
(RECEPTACLE TO BE  
ACCESSIBLE FROM  
SERVICE ACCESS)  
32"  
STEAM  
GENERATOR  
16-5/8"  
SHUT OFF  
VALVE  
8-1/2"  
45-3/8"  
TOP VIEW  
1" TILE FLANGE  
18-5/8"  
STEAM HEAD AND SHIELD  
( PRE-INSTALLED AND  
CONNECTED TO  
STEAM GENERATOR)  
SERVICE  
ACCESS  
(LEFT HAND UNIT SHOWN)  
SIDE VIEW  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Framing and Support  
The drain extends below the bottom of the base. Note that this requires a cutout in the floor.  
The floor structure beneath the base must be able to support a total weight of base, and bather. The unit  
must be supported from the bottom of the base and not from the tile flange. If the subfloor is level, no other preparation  
is necessary. You can proceed to install the base. If the subfloor is not level, you MUST level the entire surface prior  
to installing the base. The use of materials that shim or provide a level installation are allowed provided the method  
used will ensure a level base that is supported from the bottom. Materials that may be used are a floor leveling  
compound, mortar, plaster or minimal expansion structural foam having a minimum density of 5 lbs/cubic ft.; however  
the base must remain level in order for it to drain properly and the foam feet must make full contact with the leveling  
material. Both sides of a joint or splice of subfloor should be level to each other. When attaching the base flanges  
to stud wall, use shims to fill any gaps between the tile flange and studs.  
The shower base should be installed after construction of the studwall and after rough plumbing is in place using  
the self drilling screws provided with your unit.  
It is important that the framed pocket be plumb and square and that the framing members be located as detailed  
in the framing illustration.  
The protective film liner inside the base is used to prevent damage to the finish from shoes, tools, etc.  
during installation. Before installation, remove liner to inspect for any defects, reapply and do not remove  
until final cleanup.  
FRAMING AND ROUGH-IN DETAILS  
(FOR LEFT HAND UNIT)  
MINIMUM 6"  
FROM FINISHED  
CEILING  
OR BOTTOM OF  
OPTIONAL DOME  
TO  
TEMPERATURE  
SENSOR  
LOCATION  
HEIGHT OF UNIT WITH  
JACUZZI WHIRLPOOL BATH  
STEAM ENCLOSURE: 83-3/8" ±1/4".  
WITH DOME ADD 2" ±1/4"  
MAXIMUM 7'  
FROM FLOOR  
90º  
TO DIGITAL  
CONTROLLER  
LOCATION  
15-3/8"  
33-1/4"  
17-7/8"  
10-1/2" x 5"  
DRAIN CUT-OUT  
FRONT  
SUB-FLOOR  
OF DOUBLE STUDS  
FROM STEAM  
GENERATOR  
90º  
60-1/4"  
AREA FOR DRAIN OF STEAM  
GENERATOR WITH MANUAL OR  
OPTIONAL AUTOMATIC VALVE.  
EXACT LOCATION TO BE  
DETERMINED BY INSTALLER  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
2" DOME HEIGHT  
NOTE: ADDITIONAL 2" REQUIRED  
TO INSTALL OR REMOVE DOME  
DOME  
TOP OF  
ENCLOSURE  
HEADER  
85-3/8"  
77-1/2"  
12-3/4"  
5-7/8"  
UNIT WITH JACUZZI WHIRLPOOL BATH OPTIONAL STEAM ENCLOSURE  
TOP OF THRESHOLD  
Drain Down Locations  
There are several locations (left hand unit shown) where the optional automatic valve may be located when  
connecting to a drain line as shown in illustration. Right hand unit is mirror image. Exact location to be determined  
by installer.  
The manual drain valve can be moved from its current position when connecting to a drain line.  
To allow steam generator removal for maintenance or service, use a straight union.  
STEAM GENERATOR  
FLOW DIRECTION  
OPTIONAL AUTOMATIC  
DRAIN DOWN VALVE  
DRAIN  
DOWN  
OUTLET  
THIS LOCATION MAY REQUIRE  
CUT OUT IN STUD WALL  
DRAIN DOWN VALVE  
MOUNTED VERTICALLY  
REQUIRES CUT-OUT  
IN FLOOR  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Control and Temperature Sensor Cable Rough-in  
A rough-in wiring kit is provided with unit to allow installer to locate and run wires to the temperature sensor  
and digital controller before finish walls are installed.  
Control Cable Rough-in  
The low voltage control can be mounted up to 25 feet from the generator either inside or outside the steam room.  
String the 25' cable from the generator through 1/2" holes in the wall studs or ceiling joists to the controller location.  
Note: Do not staple through or damage cable. An option for tile rooms is to use the 1 gang rough-in box (provided)  
and install at the desired control mounting location. A mounting plate with proper 2" diameter hole is included with the  
control kit. Tile up to the 2" hole in the mounting plate.  
Temperature Sensor Rough-in  
It is recommended that the sensor be mounted in the steam room 6" from the ceiling or below bottom of dome, but  
not directly over the steam dispersion head or more than 7 feet above the floor. String the sensor cable from the sensor  
location through 1/2" holes in the wall studs or ceiling joists to the generator location. Leave 12" of slack at the sensor  
location. Note: Do not staple through or damage cable.  
Leave a couple of feet of sensor and control cable free behind the steam generator to allow for removal  
through access panel for maintenance or servicing if necessary.  
WATER SUPPLY  
TO  
TEMPERATURE  
SENSOR  
MANUAL WATER  
SUPPLY SHUTOFF  
VALVE (PROVIDED)  
TO DIGITAL  
CONTROLLER  
TO STEAM HEAD  
(STEAM OUTPUT  
FACTORY INSTALLED)  
PRESSURE RELIEF VALVE  
3/4 NPT (PROVIDED)  
REDUCTION FROM 3/4 NPT  
TO 1/2 NPT PERMITTED.  
NOTE: PRESSURE RELIEF DRAIN LINE,  
DRAIN LOCATION AND METHOD AS  
REQUIRED BY LOCAL CODES. (TO BE  
1/2 INCH MINIMUM SIZE COPPER)  
TANK DRAIN DOWN MANUAL VALVE (PROVIDED)  
NOTE: SITE DRAIN OR OTHER METHOD AS  
REQUIRED BY LOCAL CODES. (WITH AUTOMATIC  
DRAIN OPTION WATER DISCHARGED IS LESS  
THAN 140°F.)  
OPTIONAL AUTOMATIC  
DRAIN VALVE  
NOTE: ALL COPPER PIPE SIZES ARE TO BE INDUSTRY NOMINAL SIZES  
AND FITTINGS ARE NOT PROVIDED UNLESS OTHERWISE NOTED.  
Minerals in the water or poor water quality can shorten the life of the steam generator or cause erratic  
operation if the tank is not drained regularly. Drain the tank frequently. Jacuzzi Whirlpool Bath also strongly  
recommends purchasing and installing the optional automatic drain down valve. The tank will be drained  
automatically after each use after the water temperature lowers. Water filters and other conditioners are  
strongly recommended if the water is of poor quality.  
The Automatic Tank Drain Valve must be installed where the steam generator may be exposed to freezing  
temperatures, e.g., in seasonal-use homes. (Water supply lines and water solenoid valve must not be allowed  
to freeze.) This option prevents standing water from remaining in the tank. The tank will be automatically  
drained through this valve when the water has cooled.  
Read all warranty provisions before selecting a manual drain valve or the automatic drain down option.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Base Drain  
Water Supply  
Remove the stainless steel strainer from the drain  
assembly. Disassemble the locknut and two gaskets  
from the back of the drain assembly. Apply a 1/4" bead  
ofcaulking(silicone)tothedrainholeandinsertthedrain  
assembly. Replace the rubber washer, fiber washer,  
and lock nut in that order. Hand tighten the locknut.  
Remove excess sealant from finished side.  
Apply a lubricant (common household liquid soap  
works well) to the inside of the rubber seal of the drain  
assembly.  
Consult local authorities for plumbing code require-  
ments in your area. Connect house cold water supply to  
steam generator supply tubing.  
IMPORTANT: Jacuzzi Whirlpool Bath does not  
warrant connections of water supply fittings and  
piping or drain systems. Nor is it responsible for  
damage to the shower base which occurs during  
any installation procedure.  
WATER SUPPLY (3/8" COPPER TUBING)  
NOTE: Watertight installation of the drain is the  
installer's responsibility. Drain leakage is excluded  
from the Jacuzzi Whirlpool Bath warranty of this  
product.  
Slide the shower base into the framed opening and  
attach the shower base flange to the stud wall and  
blocking with screws provided.  
NOTE: If there is any gap between base flange and  
stud or blocking, shims MUST be used to prevent  
distortion or cracking of the flange.  
SHUT OFF VALVE  
DRAIN ASSEMBLY  
STRAINER  
APPLY  
LUBRICANT  
Electrical Connections  
A separate circuit is required. Install a NEMA 6-50R  
receptacle to the studwall at least 4 inches above the  
floor. The receptacle is not provided.  
DRAIN  
ASSEMBLY  
SILICONE  
SEALANT  
SHOWER  
BASE  
RUBBER WASHER  
NUT  
FIBER WASHER  
Withalargescrewdriverandthetoolincludedwiththe  
drain, tighten the inside compression nut to seal the  
drain pipe connection. After drain is fully installed, test  
for proper drainage. If the shower base does not drain  
properly, rectify this condition before proceeding with  
theinstallation. JacuzziWhirlpoolBathisnotrespon-  
sible for removal and/or reinstallation costs.  
LOCATE RECEPTACLE IN THIS AREA.  
RECPTACLE TO BE ACCESSIBLE  
FROM SERVICE ACCESS  
TIGHTEN SEALING NUT  
TOOL  
(INCLUDED)  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Controller Mounting  
Finished Wall Mounting  
The low voltage control can be mounted directly to a finished wall either inside or outside the steam room. Using  
a 2" hole saw, drill a hole in the finished wall where the control is to be mounted (the control cable should already be  
roughed-in to this location). Locate the control cable, pull it out through the 2" hole and plug it into the connector on  
the back of the control housing. With the decorative cover removed, screw the two 3" control housing mounting screws  
1/4" into the mounting bracket. See diagram. Run a bead of 100% silicon caulk in between the 2 ridges around the  
perimeter on the back of the control housing. See diagram. Insert the mounting bracket into the wall cavity by first  
pushingwiththecontrolhousingandthenwithahardflatsurfaceonthecontrolhousingmountingscrewswhichextend  
out through the control face. Once the mounting bracket has been inserted into the finished wall, center the control  
and tighten the mounting screws to draw the control housing securely against the finished wall. Do not over tighten  
the mounting screws. Install the decorative cover plate by sliding the top of the cover plate over the tab on the top of  
the control housing and pushing on the bottom of the cover plate to complete the snap fit.  
CONTROLLER MOUNTING IN FINISHED WALL  
WALL  
MOUNTING  
BRACKET  
CONTROL  
HOUSING  
CONTROL  
HOUSING  
CONTROL  
COVER  
PLATE  
CONTROL  
COVER  
PLATE  
CONTROL  
HOUSING  
SILICON SEALANT  
MOUNTING  
SCREWS  
Tile Wall Mounting  
String the 25' cable from the control location through 1/2" holes in wall studs to the generator. Do not staple through  
or damage the cable. Use supplied cable only. A one gang junction box (provided) must be installed at the desired  
location. A mounting plate with a 2" hole is included. Tile up to the 2" hole in the mounting plate. To mount the control  
apply silicon sealant between the 2 ridges around the perimeter on the back of the control housing and press control  
against tile. Clean up any excess sealant. Connect the cable from the back of the steam generator to the digital  
controller.  
TILE WALL MOUNTING  
STUD  
TILE  
SINGLE GANG  
JUNCTION BOX  
(PROVIDED)  
MOUNTING  
PLATE  
TILE UP  
TO 2" HOLE  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Temperature Sensor Mounting  
Finish Materials  
The temperature sensor should be mounted 6" below  
the ceiling or dome, inside the steam room, but not  
directly over the steam dispersion head or more than 7  
feet above the floor. Using a 7/8" hole saw, drill a hole  
in the finished wall where the sensor is to be mounted  
(the sensor cable should already be roughed-in to this  
location). Locatethesensorcable, pullitoutthroughthe  
hole and plug it into the temperature sensor. It is best to  
tape the sensor and cable connection together to avoid  
disconnection inside the wall. Apply silicon caulk as  
shown in diagram and insert the sensor in the hole. An  
optional trim ring is included with the sensor. If the 7/8"  
holeisjaggedoriscuttoolargethetrimringmaybeused  
to cover the exposed edges. Make sure that the sensor  
probe is pointing down once installed. Tape the sensor  
in place while the silicone hardens.  
Applytile(orotherfinishingmaterial)leavinga1/8"gap  
between the finishing material and the base flange lip.  
Seal this gap with silicone sealant. Leave a minimum  
1/4"weepholeatthebackandfrontcornersofthebase.  
The weep holes are necessary to allow drainage from  
leakage through unsealed tiled grout.  
Filling the area marked DO NOT FILL will prevent  
moisture from draining back into the base through the  
weep holes. This moisture is due to leakage through the  
tile grout. Sealing the tile grout will prevent this leakage.  
ADHESIVE  
CEMENT  
TILE  
BOARD  
SILICONE  
WALL  
SILICONE SEALANT  
SEALANT  
DO NOT  
FILL  
STUD  
PROBE MUST  
POINT  
DOWNWARD  
PIGTAIL  
OPTIONAL  
TRIM RING  
7/8" HOLE  
FRONT WEEP HOLE  
SILICONE  
SEALANT  
Flange Mounting  
After base is in position secure flange to studs with  
screws provided. If there is a gap between flange and  
stud shims MUST be used.  
TYPICAL FLANGE MOUNTING DETAIL  
1/4" MINIMUM  
WEEP HOLE  
STUD  
FLANGE  
ATTACH WITH  
SCREWS  
PROVIDED  
REAR WEEP HOLE  
TILE  
SHIM IF NECESSARY TO  
FILL GAPS BETWEEN  
STUD AND FLANGE  
1/4" MINIMUM  
WEEP HOLE  
STUD  
SILICONE  
SEALANT  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Note: The combined thickness of the tile (or other  
finish material), adhesive and cement board must not  
exceed the edge of the vertical wall on the drain side.  
Thisconditionwillnotallowthewalljambofthesteam  
enclosure to sit flat against the vertical wall.  
Service Access  
Service access is through the removable panel. To  
remove panel, grab the middle of the panel and bow  
outwards till clips disengage.  
SERVICE ACCESS PANEL  
FINISH SURFACE  
DRAIN  
TILE FLUSH WITH  
VERTICAL WALL  
GRAB PANEL IN MIDDLE  
AND BOW OUTWARDS  
To reinstall the panel hold at an angle to the skirt and  
insert clip under edge of skirt opening. Bow the panel  
outward and insert clip on other side.  
If there is a gap between the finish surface and the  
vertical wall, a filler piece (included with steam enclo-  
sure) may be required. Gap must not exceed 3/16".  
Silicone sealant will also be necessary to eliminate any  
additional gaps that may be present.  
ACCESS  
PANEL  
FINISH SURFACE  
DRAIN  
BOW ACCESS  
PANEL OUTWARD  
FROM CENTER  
SHELL  
TILE NOT FLUSH WITH  
VERTICAL WALL  
3/16"  
MAXIMUM  
GAP  
VERTICAL WALL  
Clean-Up After Installation  
To avoid dulling and scratching the surface of the  
shower base, never use abrasive cleaners. A mild liquid  
detergent and warm water will clean soiled surfaces.  
Remove spilled plaster with a wood or plastic edge.  
Metal tools will scratch the surface. Spots left by plaster  
or grout can be removed if lightly rubbed with detergent  
on a damp cloth or sponge.  
Paint, tar, or other difficult stains can be removed with  
paint thinner, turpentine, or isopropyl alcohol (rubbing  
alcohol).  
Minor scratches which do not penetrate the color  
finish can be removed by lightly sanding with 600-grit  
wet/dry sandpaper. You can restore the glossy finish to  
the acrylic surface of the shower base with a special  
compound, Meguiar's #10 Mirror Glaze. If that is not  
available, use automotive rubbing compound followed  
by an application of automotive paste wax.  
Major scratches and gouges which penetrate the  
acrylic surface will require refinishing. Ask your Jacuzzi  
Whirlpool Bath dealer for special instructions.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
The digital control features an adjustable 60 minute time and temperature control with digital display. The actual  
room temperature and time remaining are alternately displayed every 5 seconds. The temperature can be adjusted  
in a range between 100 degrees and 125 degrees Fahrenheit with an initial default of 120 degrees. Once the set  
temperature is reached the ‘’soft steam’’ feature automatically engages cutting steam production back to a single  
element. If the steam room temperature drops more than 5 degrees both elements will automatically engage.  
Operation of Your Digital Time and Temperature Control  
1. Be sure the power circuit and water supply to the generator are on.  
2. Press the ON/OFF button on the control until the temperature is displayed.  
3.Thegeneratorshouldproducesteamin5to10minutesandwillturnoffautomaticallyin60minutesorlessdepending  
on the set time. The control will alternately display time remaining and the actual temperature at the sensor in your  
steam room every 5 seconds.  
4. To change the time setting press and hold the TIME button on the control. Continuing to hold the button will cause  
the time to increase in 5 minute increments from the prior setting. At 60 minutes the time setting will scroll backwards  
to 5 minutes. To shut down the generator press the ON/OFF button.  
5. To change the preset temperature setting press and hold the TEMP button on the control. While continuing to hold  
the button, the temperature display will increase in 1 degree increments from the prior setting to 125 degrees  
Fahrenheit. At 125 degrees Fahrenheit the temperature setting will decrease in 1 degree increment to the lowest  
setting, 100 degrees Fahrenheit.  
6. The TIME and TEMP set points are remembered for your next bath unless power to the steam generator is lost.  
Maintenance of the SteamPro Unit  
Maintenance of the SteamPro includes flushing and visually inspecting for water leaks.  
To remove the unit remove the access panel. Turn off power to the unit and disengage the power cord. Turn the  
water supply off at the shut off valve and drain the tank (if necessary). Disconnect all plumbing. Cut and discard  
shipping restraint. Remove 2 screws holding mounting bracket to wood plank. Slide unit toward front of base and  
remove. Thereinstallationisthereverseoftheremovalprocedure. Itisnotnecessarytoreplacetheshippingrestraint.  
SHIPPING RESTRAINT  
WATER SUPPLY  
SHUT OFF VALVE  
TO STEAM HEAD  
MOUNTING BRACKET  
REMOVE SCREWS  
DRAIN DOWN  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting  
There are no user serviceable parts in the Generator. All repair should be performed by a qualified service person.  
For additional assistance or the factory authorized service person nearest you call the Service Department at 1-800-  
363-0251 (This number is only for service for the steam generator.). The Trouble Shooting Guide below is meant as  
a general aid only. Follow ACTION TO BE TAKEN in order until the problem is resolved.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wiring Diagram  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRODUCT SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.  
USE INSTALLATION INSTRUCTIONS SUPPLIED WITH PRODUCT.  
Jacuzzi Whirlpool Shower base has obtained applicable code (standards) listings generally available on a national basis for  
products of this type. It is the responsibility of the installer/owner to determine specific local code compliance prior to installation  
of the product. Jacuzzi Whirlpool Shower base makes no representation or warranty regarding, and will not be responsible for any  
code compliance.  
Jacuzzi Whirlpool Bath National Headquarters  
P.O. Drawer J, Walnut Creek, CA 94596 (925) 938-7070  
Service Support: Call (800) 288-4002  
©2002 Jacuzzi Whirlpool Bath T87100B 2/04  
Printed on Recycled Paper  
Printed in the U.S.A.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Jacuzzi Whirlpool Bath Limited Warranty  
Steam Generator Products  
Jacuzzi Whirlpool Bath, warrants that its Steam Generators (warranted products) are free of manufacturing defects  
both as to workmanship and material for 5 years and it will replace or repair defective parts or equipment for the period  
of time and in accordance with the conditions set forth below. The terms of the warranty will be administered by  
Saunatec Inc. dba, AMEREC.  
1. Applicability. This warranty applies when the warranted product (a) is installed in accordance with installation  
instructions provided, (b) is properly and reasonably maintained, and (c) has not been subjected to damage, misuse,  
or abuse.  
2. Registration. This warranty becomes valid only after the Limited Warranty Registration form, provided with this  
warranty, iscompletelyfilledinandsignedbytheoriginalpurchaserandmailedtoAMERECwithinsixty(60)daysfrom  
the date of original installation. This warranty is nontransferable and shall extend only to the original purchaser.  
3. Duration of Warranty. AMEREC or it’s authorized representative will provide parts to replace those with  
manufacturing or workmanship defects for a period of five (5) years from the date of original installation, except when  
the warranted product is installed in commercial locations such as clubs, condominiums, apartments, spas or military  
facilities. In commercial locations, AMEREC or its authorized representative will provide parts to replace those with  
manufacturing or workmanship defects for a period of one (1) year from the date of original installation. Additionally,  
for noncommercial locations in the United States AMEREC or its authorized representative will provide reasonable  
labor to replace defective parts for a period of two (2) years from the date of original installation and three  
(3) additional years if the product is returned to the factory.  
4. Warranty Work. All warranty work must be (a) authorized by AMEREC before it is performed; and (b) performed  
only by authorized AMEREC representatives. This warranty shall not apply to any charges for parts or labor incurred  
before receiving approval by AMEREC.  
5. Return Authorization Number. A return authorization number assigned by an AMEREC representative must  
accompany all returned parts. Parts which are returned without a return authorization number may not be repaired  
or replaced.  
Jacuzzi Whirlpool Bath  
C/O AMEREC  
P.O. Box 2258  
Woodinville WA, 98072  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Procedure. Requests for repair or replacement, a return authorization number, or warranty information should be  
directed to AMEREC by calling toll-free 1-800-363-0251 or by writing to AMEREC, 17683 128th Place N.E.,  
Woodinville, WA 98072. Defective product or parts returned for repair or replacement must be shipped prepaid to  
AMEREC at the above address. Shipping costs for return of replacement product or parts to the purchaser will be at  
the expense of the purchaser.  
7. Limitations, Exclusions, and Remedies. There are no warranties which extend beyond the descriptions on the face  
hereof. This limited warranty is in lieu of all warranties, expressed or implied, and of all other obligations or liabilities  
on the part of Jacuzzi Whirlpool Bath. There shall be no implied warranty of merchantability. Jacuzzi Whirlpool Bath  
neither assumes nor authorizes any person to assume for it any other obligation or liability in connection with the sale  
of its products. Damages for breach of this warranty shall not exceed the lesser of the cost of repair or replacement.  
Repair or replacement shall be the exclusive remedy available to the purchaser.  
Under no circumstances shall Jacuzzi Whirlpool Bath be liable by virtue of this warranty or otherwise for any special,  
indirect, secondary, incidental, or consequential damage of any nature to any person or property arising directly or  
indirectly out of the use or inability to use a warranted product.  
Some States do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental  
or consequential damages, so the above limitations and exclusions may not apply to you.  
8. Disputes. Any lawsuit alleging breach of this limited warranty shall be commenced within one year from the date  
of breach. In addition, any such lawsuit may be commenced only in King County, Washington.  
This warranty gives you specific legal rights, and you may also have other rights which vary from State to State.  
LIMITED WARRANTY REGISTRATION FORM  
Please fill out and return within 60 days of installation to:  
AMEREC, P.O. Box 2258, Woodinville WA 98072  
The undersigned hereby acknowledges the receipt of Jacuzzi Whirlpool Bath Limited Warranty and affirms that the  
date of installation was_____________________20____, further that installation of the equipment has been  
completed according to the Jacuzzi Whirlpool Bath installation instructions furnished with the equipment and that I  
have read, understand and agree to the conditions and terms of the Jacuzzi Whirlpool Bath Limited Warranty in its  
entirety.  
Name of Purchaser ___________________________________________________________________  
Address ______________________ City__________________ St. ___________________ Zip _____  
Phone _____________________________________________________________________________  
Purchaser’s Signature _________________________________________________________________  
Model No. & Serial No. ________________________________________________________________  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Jacuzzi Whirlpool Bath Limited Warranty  
Builder Group Bath Product  
WARRANTY COVERAGE  
Jacuzzi Whirlpool Bath (the “Company”) offers the following express limited warranty to the original purchaser of any Jacuzzi Whirlpool Bath Builder Group  
Bath Product (“unit”) who purchases the product for personal or single family use (“user”). The Company will repair or replace, at its option, the unit or its  
equipment in accordance with the following terms and conditions.  
ONE YEAR LIMITED WARRANTY ON BATHS  
Our warranty on Builder Group Bath products is for one (1) year. Our warranty covers the unit and factory-installed components (e.g., pump, motor)  
against defects in material or workmanship. Warranty coverage begins on the date the unit was originally purchased by the user.  
NINETY DAY (PARTS ONLY) LIMITED WARRANTY ON OPTIONS AND ACCESSORIES  
Our warranty on options and accessories manufactured by the Company is for ninety (90) days for parts only. Our warranty covers options and accessories  
manufactured by the Company (e.g., fill spout kits, trim kits, skirts) against defects of material or workmanship. Warranty coverage begins on the date the option  
or accessory was originally purchased by the user.  
WARRANTY LIMITATIONS  
Our warranty does not cover defects, damage, or failure caused by the common carrier, installer, user, or other person, or resulting from, without limitation,  
any of the following: careless handling (lifting unit by plumbing, abrading finish, etc.) including its own negligence; modification of any type for any reason  
(including modification to meet local codes); improper installation (including installation not in accordance with instructions and specifications provided with  
the unit); connections supplied by the installer of the equipment; improper voltage supply or unauthorized electrical modification; misuse; incorrect operation,  
or lack of proper routine maintenance; operation of the unit without specified minimum amount of water or at inappropriate water temperature; use of abrasive  
or improper cleaners; or acts of God, such as lightning, floods, earthquakes, etc.  
In addition, THE COMPANY WILL NOT BE RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES or losses arising from any cause  
(e.g., water damage to carpet, ceiling, loss of use, etc.) including its own negligence; damages to, respecting, or resulting from: plated parts when pool and/or spa  
chemicals are used in the unit; optional bath equipment not manufactured by the Company, supplied by Dealer, installer or the Company; the unit's prior usage  
as an operational display; or defects that should have been discovered before installation. This limited warranty does not include: labor, transportation, or other  
costs incurred in the removal and/or reinstallation of the original unit and/or installation of a replacement unit; any costs relating to obtaining access for repair;  
or loss of use damage, including loss of sales, profit or business advantage of any kind under any circumstances. Bath units in commercial use are excluded from  
any warranty coverage if any addition, deletion, or modification of any kind whatsoever has been made to the unit (or to any component).  
Warranty coverage is provided in the United States of America and Canada.  
IMPLIED WARRANTIES  
Implied warranties of merchantability and fitness for a particular purpose are disclaimed altogether or to the full extent allowed by law.  
NOTICE: This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. There are no warranties applicable  
to Jacuzzi Whirlpool Bath products except as expressly stated herein or as implied by applicable state and federal laws. The Company will not be responsible for  
any statements or representations made in any form that go beyond, are broader than or are inconsistent with any authorized literature or specifications furnished  
by the Company.  
Some states do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so the above  
limitations and exclusions may not apply to you.  
RETURN OF WARRANTY CARD  
The attached Warranty Registration Card MUST be filled out by the purchaser within thirty (30) days from purchase and mailed to Jacuzzi Whirlpool Bath  
in order for this warranty to become effective.  
Jacuzzi Whirlpool Bath  
P.O. Drawer J  
Walnut Creek, CA 94596-9885  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RESPONSIBILITIES OF OTHERS  
Inspectingtheunitpriortoinstallationistheresponsibilityoftheinstallerorbuildingcontractorwhoactsonbehalfoftheuser.Theyareresponsibleforensuring  
the unit is free of defect or damage. Notices are placed on and in the unit and on the shipping carton advising the installer of this responsibility. In the event of  
a problem, the unit must not be installed. The Company is not responsible for failures or damage that could have been discovered, repaired, or avoided by proper  
inspection and testing prior to installation.  
Damage occurring in transit is the responsibility of the carrier. The user or installer MUST open the crate and inspect the unit for damage when it is delivered.  
If damage is discovered, it must be reported immediately to the seller and the carrier in writing, and an inspection requested. Failure of the carrier to respond should  
be reported to the seller and the carrier. Your freight claims should be filed promptly thereafter.  
It is the responsibility of the installer, building contractor, or user to provide access for service. The Company is not responsible for any costs relating to  
obtaining access for repair. The user shall bear such costs and, if appropriate, must seek recovery from the installer.  
Damage occurring to the unit during installation is the responsibility of the installer and/or building contractor and damage occurring thereafter is the  
responsibility of the user.  
Failure of any optional equipment is the sole responsibility of the equipment manufacturer. (Options and accessories manufactured by the Company are  
warranted for ninety (90) days from the original date of purchase for parts only.)  
The Distributor or Dealer is responsible for knowing local code requirements and notifying the installing contractor and/or user of these requirements at the  
time of purchase. The Company is not responsible for costs to modify any product to obtain any code approval, such as city, county, or state building codes in  
U.S.A. or municipal or provincial codes in Canada.  
WARRANTY SERVICE  
For the customer's benefit, the Company maintains a list of independent service personnel to perform required warranty service repairs. Such firms are not agents  
or representatives of the Company and cannot bind the Company by words or conduct.  
The Company will provide the warranty service described above when the following conditions have been met: the failure is of the nature or type covered  
by the warranty; the user has informed an Authorized Jacuzzi Whirlpool Bath Service Agent or Warranty Service Department Representative of the nature of the  
problem during the warranty period; conclusive evidence (e.g., proof of purchase or installation) is provided to the foregoing by the user proving that the failure  
occurred or was discovered within the warranty period; an authorized independent service person or Company representative has been permitted to inspect the  
unit during regular business hours within a reasonable time after the problem was reported by the user.  
Inordertoobtainwarrantyservice,consultyourlocaltelephonebookforthelocationofthenearestJacuzziWhirlpoolBathAuthorizedServiceAgent.Describe  
the problem and the Authorized Service Agent will inspect the unit and provide the required warranty service.  
If you are unable to contact a Jacuzzi Whirlpool Bath Authorized Service Agent, call or write:  
Jacuzzi Whirlpool Bath  
Warranty Service Department  
P.O. Drawer J  
Walnut Creek, California 94596  
Call: (800) 288-4002  
To obtain warranty replacement for factory-installed components for Company supplied options and accessories manufactured and supplied by the Company,  
call or write the above. Provide a description of the problem and proof of purchase. You will be instructed how to obtain replacements and where to return, at  
your expense, the failed component(s), option(s), or accessory(ies).  
All replacement parts, equipment, and repairs shall assume the remaining warranty period of the part(s) replaced.  
The Company's warranty obligation shall be discharged upon tender of replacement or repair. The customer's refusal to accept the tender terminates the  
Company's warranty obligation.  
©2002 Jacuzzi Whirlpool Bath T871000B 2/04  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Ingersoll Rand Cordless Drill 8670 1 User Manual
Insignia Work Light NS 55D440NA14 User Manual
Intelligent Motion Systems Welding System Integral Driver and Power Supply User Manual
Jonsered Trimmer HT 2124 User Manual
JVC DVD Player XV N50BK User Manual
Kambrook Fan KFH320 User Manual
Kenmore Food Processor 10080002 User Manual
Kenwood Speaker KSC 9903 User Manual
Kodak Projector EKTAPRO User Manual
Kompernass Food Processor KH 1160 User Manual