		 SEDONA™   
					Steam & Shower Base   
					INSTALLATION/OPERATING INSTRUCTIONS   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				CONTENTS   
					Specifications _________________________________________________________________________ 2   
					Roughing-in Reference _________________________________________________________________ 2   
					Framing and Support ___________________________________________________________________ 3   
					Steam Enclosure _____________________________________________________________________ 4   
					SteamPro™ Drain Down Configurations ___________________________________________________ 4   
					Digital Control & Temperature Sensor Rough-in _____________________________________________ 5   
					Drain Information ______________________________________________________________________ 6   
					Plumbing and Water Supply ______________________________________________________________ 6   
					Electrical Connections___________________________________________________________________ 6   
					Digital Controller Mounting _______________________________________________________________ 7   
					Temperature Sensor Mounting ____________________________________________________________ 8   
					Flange Mounting _______________________________________________________________________ 8   
					Finish Materials ______________________________________________________________________ 8-9   
					Service Access _______________________________________________________________________ 9   
					Operation ____________________________________________________________________________ 10   
					Maintenance __________________________________________________________________________ 10   
					Troubleshooting _______________________________________________________________________ 11-12   
					SteamPro™ Wiring Diagram ______________________________________________________________ 13   
					SteamPro™ Warranty __________________________________________________________________ 15-16   
					Base Warranty ________________________________________________________________________ 17-18   
					Save These Instructions for Future Use.   
					Owner's Record   
					Date Purchased ____________________________________________________________   
					Purchased From ____________________________________________________________   
					Installed By ________________________________________________________________   
					Serial Number (Base) ________________________________________________________   
					Serial Number (Steam Generator) ______________________________________________   
					Model ____________________________________________________________________   
					1 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Important: Read complete instructions before beginning installation.   
					Each shower base is shipped with a drain and stainless steel strainer   
					Remove the shower base from the carton. Do not destroy the shipping carton until after satisfactory   
					inspection of the product.   
					Immediately upon receipt, inspect the base before installing. Should inspection reveal any damage or defect in the   
					finish, do not install the base. Damage or defect to the finish claimed after the base is installed is excluded from the   
					warranty. Jacuzzi Whirlpool Bath’s responsibility for shipping damage ceases upon delivery of the products in good   
					order to the carrier. Refer any claims for damage to the carrier. For definitions of warranty coverage and limitations,   
					refer to the published warranty information packaged with the product. Jacuzzi Whirlpool Bath is not responsible for   
					any defect that could have been discovered, repaired, or avoided by following this inspection and testing procedure.   
					Plan the installation in relation to the finished wall surfaces. Take into account the dimensions of both the shower   
					base and the shower door enclosure to be used with it.   
					NOTE: Damage or defects which could have been discovered and repaired prior to installation and which are claimed   
					after final installation of the product are excluded from our warranty.   
					SPECIFICATIONS   
					PRODUCT   
					WEIGHT   
					TOTAL WEIGHT/   
					FLOOR LOADING   
					DIMENSIONS   
					ELECTRICAL   
					60"   
					32"   
					(1524 mm) L   
					( 813 mm) W   
					110 lb   
					(50 kg)   
					*230 VAC, 60 Hz.   
					40 AMP, 3 Wire   
					Requires a   
					Dedicated Separate   
					Circuit.   
					310 lbs   
					(141 kg)   
					/23 lb/sq. ft.   
					(112 kg/sq. m)   
					18-5/8" ( 473 mm) H   
					*SteamPro supplied with NEMA 6-50P plug. NEMA 6-50R receptacle required.   
					Product specifications are subject to change without notice.   
					60"   
					LOCATION FOR   
					INCOMING WATER   
					SUPPLY LINE TO   
					RECEPTACLE   
					STEAMER (INSTALLED   
					AND PREPLUMBED   
					WITH 3/8" COPPER   
					TUBINGTO STEAM   
					GENERATOR WITH   
					SHUT OFF VALVE)   
					LOCATION   
					(RECEPTACLE TO BE   
					ACCESSIBLE FROM   
					SERVICE ACCESS)   
					32"   
					STEAM   
					GENERATOR   
					16-5/8"   
					SHUT OFF   
					VALVE   
					8-1/2"   
					45-3/8"   
					TOP VIEW   
					1" TILE FLANGE   
					18-5/8"   
					STEAM HEAD AND SHIELD   
					( PRE-INSTALLED AND   
					CONNECTED TO   
					STEAM GENERATOR)   
					SERVICE   
					ACCESS   
					(LEFT HAND UNIT SHOWN)   
					SIDE VIEW   
					2 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Framing and Support   
					The drain extends below the bottom of the base. Note that this requires a cutout in the floor.   
					The floor structure beneath the base must be able to support a total weight of base, and bather. The unit   
					must be supported from the bottom of the base and not from the tile flange. If the subfloor is level, no other preparation   
					is necessary. You can proceed to install the base. If the subfloor is not level, you MUST level the entire surface prior   
					to installing the base. The use of materials that shim or provide a level installation are allowed provided the method   
					used will ensure a level base that is supported from the bottom. Materials that may be used are a floor leveling   
					compound, mortar, plaster or minimal expansion structural foam having a minimum density of 5 lbs/cubic ft.; however   
					the base must remain level in order for it to drain properly and the foam feet must make full contact with the leveling   
					material. Both sides of a joint or splice of subfloor should be level to each other. When attaching the base flanges   
					to stud wall, use shims to fill any gaps between the tile flange and studs.   
					The shower base should be installed after construction of the studwall and after rough plumbing is in place using   
					the self drilling screws provided with your unit.   
					It is important that the framed pocket be plumb and square and that the framing members be located as detailed   
					in the framing illustration.   
					The protective film liner inside the base is used to prevent damage to the finish from shoes, tools, etc.   
					during installation. Before installation, remove liner to inspect for any defects, reapply and do not remove   
					until final cleanup.   
					FRAMING AND ROUGH-IN DETAILS   
					(FOR LEFT HAND UNIT)   
					MINIMUM 6"   
					FROM FINISHED   
					CEILING   
					OR BOTTOM OF   
					OPTIONAL DOME   
					TO   
					TEMPERATURE   
					SENSOR   
					LOCATION   
					HEIGHT OF UNIT WITH   
					JACUZZI WHIRLPOOL BATH   
					STEAM ENCLOSURE: 83-3/8" ±1/4".   
					WITH DOME ADD 2" ±1/4"   
					MAXIMUM 7'   
					FROM FLOOR   
					90º   
					TO DIGITAL   
					CONTROLLER   
					LOCATION   
					15-3/8"   
					33-1/4"   
					17-7/8"   
					10-1/2" x 5"   
					DRAIN CUT-OUT   
					FRONT   
					SUB-FLOOR   
					OF DOUBLE STUDS   
					FROM STEAM   
					GENERATOR   
					90º   
					60-1/4"   
					AREA FOR DRAIN OF STEAM   
					GENERATOR WITH MANUAL OR   
					OPTIONAL AUTOMATIC VALVE.   
					EXACT LOCATION TO BE   
					DETERMINED BY INSTALLER   
					3 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				2" DOME HEIGHT   
					NOTE: ADDITIONAL 2" REQUIRED   
					TO INSTALL OR REMOVE DOME   
					DOME   
					TOP OF   
					ENCLOSURE   
					HEADER   
					85-3/8"   
					77-1/2"   
					12-3/4"   
					5-7/8"   
					UNIT WITH JACUZZI WHIRLPOOL BATH OPTIONAL STEAM ENCLOSURE   
					TOP OF THRESHOLD   
					Drain Down Locations   
					There are several locations (left hand unit shown) where the optional automatic valve may be located when   
					connecting to a drain line as shown in illustration. Right hand unit is mirror image. Exact location to be determined   
					by installer.   
					The manual drain valve can be moved from its current position when connecting to a drain line.   
					To allow steam generator removal for maintenance or service, use a straight union.   
					STEAM GENERATOR   
					FLOW DIRECTION   
					OPTIONAL AUTOMATIC   
					DRAIN DOWN VALVE   
					DRAIN   
					DOWN   
					OUTLET   
					THIS LOCATION MAY REQUIRE   
					CUT OUT IN STUD WALL   
					DRAIN DOWN VALVE   
					MOUNTED VERTICALLY   
					REQUIRES CUT-OUT   
					IN FLOOR   
					4 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Control and Temperature Sensor Cable Rough-in   
					A rough-in wiring kit is provided with unit to allow installer to locate and run wires to the temperature sensor   
					and digital controller before finish walls are installed.   
					Control Cable Rough-in   
					The low voltage control can be mounted up to 25 feet from the generator either inside or outside the steam room.   
					String the 25' cable from the generator through 1/2" holes in the wall studs or ceiling joists to the controller location.   
					Note: Do not staple through or damage cable. An option for tile rooms is to use the 1 gang rough-in box (provided)   
					and install at the desired control mounting location. A mounting plate with proper 2" diameter hole is included with the   
					control kit. Tile up to the 2" hole in the mounting plate.   
					Temperature Sensor Rough-in   
					It is recommended that the sensor be mounted in the steam room 6" from the ceiling or below bottom of dome, but   
					not directly over the steam dispersion head or more than 7 feet above the floor. String the sensor cable from the sensor   
					location through 1/2" holes in the wall studs or ceiling joists to the generator location. Leave 12" of slack at the sensor   
					location. Note: Do not staple through or damage cable.   
					Leave a couple of feet of sensor and control cable free behind the steam generator to allow for removal   
					through access panel for maintenance or servicing if necessary.   
					WATER SUPPLY   
					TO   
					TEMPERATURE   
					SENSOR   
					MANUAL WATER   
					SUPPLY SHUTOFF   
					VALVE (PROVIDED)   
					TO DIGITAL   
					CONTROLLER   
					TO STEAM HEAD   
					(STEAM OUTPUT   
					FACTORY INSTALLED)   
					PRESSURE RELIEF VALVE   
					3/4 NPT (PROVIDED)   
					REDUCTION FROM 3/4 NPT   
					TO 1/2 NPT PERMITTED.   
					NOTE: PRESSURE RELIEF DRAIN LINE,   
					DRAIN LOCATION AND METHOD AS   
					REQUIRED BY LOCAL CODES. (TO BE   
					1/2 INCH MINIMUM SIZE COPPER)   
					TANK DRAIN DOWN MANUAL VALVE (PROVIDED)   
					NOTE: SITE DRAIN OR OTHER METHOD AS   
					REQUIRED BY LOCAL CODES. (WITH AUTOMATIC   
					DRAIN OPTION WATER DISCHARGED IS LESS   
					THAN 140°F.)   
					OPTIONAL AUTOMATIC   
					DRAIN VALVE   
					NOTE: ALL COPPER PIPE SIZES ARE TO BE INDUSTRY NOMINAL SIZES   
					AND FITTINGS ARE NOT PROVIDED UNLESS OTHERWISE NOTED.   
					Minerals in the water or poor water quality can shorten the life of the steam generator or cause erratic   
					operation if the tank is not drained regularly. Drain the tank frequently. Jacuzzi Whirlpool Bath also strongly   
					recommends purchasing and installing the optional automatic drain down valve. The tank will be drained   
					automatically after each use after the water temperature lowers. Water filters and other conditioners are   
					strongly recommended if the water is of poor quality.   
					The Automatic Tank Drain Valve must be installed where the steam generator may be exposed to freezing   
					temperatures, e.g., in seasonal-use homes. (Water supply lines and water solenoid valve must not be allowed   
					to freeze.) This option prevents standing water from remaining in the tank. The tank will be automatically   
					drained through this valve when the water has cooled.   
					Read all warranty provisions before selecting a manual drain valve or the automatic drain down option.   
					5 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Base Drain   
					Water Supply   
					Remove the stainless steel strainer from the drain   
					assembly. Disassemble the locknut and two gaskets   
					from the back of the drain assembly. Apply a 1/4" bead   
					ofcaulking(silicone)tothedrainholeandinsertthedrain   
					assembly. Replace the rubber washer, fiber washer,   
					and lock nut in that order. Hand tighten the locknut.   
					Remove excess sealant from finished side.   
					Apply a lubricant (common household liquid soap   
					works well) to the inside of the rubber seal of the drain   
					assembly.   
					Consult local authorities for plumbing code require-   
					ments in your area. Connect house cold water supply to   
					steam generator supply tubing.   
					IMPORTANT: Jacuzzi Whirlpool Bath does not   
					warrant connections of water supply fittings and   
					piping or drain systems. Nor is it responsible for   
					damage to the shower base which occurs during   
					any installation procedure.   
					WATER SUPPLY (3/8" COPPER TUBING)   
					NOTE: Watertight installation of the drain is the   
					installer's responsibility. Drain leakage is excluded   
					from the Jacuzzi Whirlpool Bath warranty of this   
					product.   
					Slide the shower base into the framed opening and   
					attach the shower base flange to the stud wall and   
					blocking with screws provided.   
					NOTE: If there is any gap between base flange and   
					stud or blocking, shims MUST be used to prevent   
					distortion or cracking of the flange.   
					SHUT OFF VALVE   
					DRAIN ASSEMBLY   
					STRAINER   
					APPLY   
					LUBRICANT   
					Electrical Connections   
					A separate circuit is required. Install a NEMA 6-50R   
					receptacle to the studwall at least 4 inches above the   
					floor. The receptacle is not provided.   
					DRAIN   
					ASSEMBLY   
					SILICONE   
					SEALANT   
					SHOWER   
					BASE   
					RUBBER WASHER   
					NUT   
					FIBER WASHER   
					Withalargescrewdriverandthetoolincludedwiththe   
					drain, tighten the inside compression nut to seal the   
					drain pipe connection. After drain is fully installed, test   
					for proper drainage. If the shower base does not drain   
					properly, rectify this condition before proceeding with   
					theinstallation. JacuzziWhirlpoolBathisnotrespon-   
					sible for removal and/or reinstallation costs.   
					LOCATE RECEPTACLE IN THIS AREA.   
					RECPTACLE TO BE ACCESSIBLE   
					FROM SERVICE ACCESS   
					TIGHTEN SEALING NUT   
					TOOL   
					(INCLUDED)   
					6 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Controller Mounting   
					Finished Wall Mounting   
					The low voltage control can be mounted directly to a finished wall either inside or outside the steam room. Using   
					a 2" hole saw, drill a hole in the finished wall where the control is to be mounted (the control cable should already be   
					roughed-in to this location). Locate the control cable, pull it out through the 2" hole and plug it into the connector on   
					the back of the control housing. With the decorative cover removed, screw the two 3" control housing mounting screws   
					1/4" into the mounting bracket. See diagram. Run a bead of 100% silicon caulk in between the 2 ridges around the   
					perimeter on the back of the control housing. See diagram. Insert the mounting bracket into the wall cavity by first   
					pushingwiththecontrolhousingandthenwithahardflatsurfaceonthecontrolhousingmountingscrewswhichextend   
					out through the control face. Once the mounting bracket has been inserted into the finished wall, center the control   
					and tighten the mounting screws to draw the control housing securely against the finished wall. Do not over tighten   
					the mounting screws. Install the decorative cover plate by sliding the top of the cover plate over the tab on the top of   
					the control housing and pushing on the bottom of the cover plate to complete the snap fit.   
					CONTROLLER MOUNTING IN FINISHED WALL   
					WALL   
					MOUNTING   
					BRACKET   
					CONTROL   
					HOUSING   
					CONTROL   
					HOUSING   
					CONTROL   
					COVER   
					PLATE   
					CONTROL   
					COVER   
					PLATE   
					CONTROL   
					HOUSING   
					SILICON SEALANT   
					MOUNTING   
					SCREWS   
					Tile Wall Mounting   
					String the 25' cable from the control location through 1/2" holes in wall studs to the generator. Do not staple through   
					or damage the cable. Use supplied cable only. A one gang junction box (provided) must be installed at the desired   
					location. A mounting plate with a 2" hole is included. Tile up to the 2" hole in the mounting plate. To mount the control   
					apply silicon sealant between the 2 ridges around the perimeter on the back of the control housing and press control   
					against tile. Clean up any excess sealant. Connect the cable from the back of the steam generator to the digital   
					controller.   
					TILE WALL MOUNTING   
					STUD   
					TILE   
					SINGLE GANG   
					JUNCTION BOX   
					(PROVIDED)   
					MOUNTING   
					PLATE   
					TILE UP   
					TO 2" HOLE   
					7 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Temperature Sensor Mounting   
					Finish Materials   
					The temperature sensor should be mounted 6" below   
					the ceiling or dome, inside the steam room, but not   
					directly over the steam dispersion head or more than 7   
					feet above the floor. Using a 7/8" hole saw, drill a hole   
					in the finished wall where the sensor is to be mounted   
					(the sensor cable should already be roughed-in to this   
					location). Locatethesensorcable, pullitoutthroughthe   
					hole and plug it into the temperature sensor. It is best to   
					tape the sensor and cable connection together to avoid   
					disconnection inside the wall. Apply silicon caulk as   
					shown in diagram and insert the sensor in the hole. An   
					optional trim ring is included with the sensor. If the 7/8"   
					holeisjaggedoriscuttoolargethetrimringmaybeused   
					to cover the exposed edges. Make sure that the sensor   
					probe is pointing down once installed. Tape the sensor   
					in place while the silicone hardens.   
					Applytile(orotherfinishingmaterial)leavinga1/8"gap   
					between the finishing material and the base flange lip.   
					Seal this gap with silicone sealant. Leave a minimum   
					1/4"weepholeatthebackandfrontcornersofthebase.   
					The weep holes are necessary to allow drainage from   
					leakage through unsealed tiled grout.   
					Filling the area marked DO NOT FILL will prevent   
					moisture from draining back into the base through the   
					weep holes. This moisture is due to leakage through the   
					tile grout. Sealing the tile grout will prevent this leakage.   
					ADHESIVE   
					CEMENT   
					TILE   
					BOARD   
					SILICONE   
					WALL   
					SILICONE SEALANT   
					SEALANT   
					DO NOT   
					FILL   
					STUD   
					PROBE MUST   
					POINT   
					DOWNWARD   
					PIGTAIL   
					OPTIONAL   
					TRIM RING   
					7/8" HOLE   
					FRONT WEEP HOLE   
					SILICONE   
					SEALANT   
					Flange Mounting   
					After base is in position secure flange to studs with   
					screws provided. If there is a gap between flange and   
					stud shims MUST be used.   
					TYPICAL FLANGE MOUNTING DETAIL   
					1/4" MINIMUM   
					WEEP HOLE   
					STUD   
					FLANGE   
					ATTACH WITH   
					SCREWS   
					PROVIDED   
					REAR WEEP HOLE   
					TILE   
					SHIM IF NECESSARY TO   
					FILL GAPS BETWEEN   
					STUD AND FLANGE   
					1/4" MINIMUM   
					WEEP HOLE   
					STUD   
					SILICONE   
					SEALANT   
					8 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Note: The combined thickness of the tile (or other   
					finish material), adhesive and cement board must not   
					exceed the edge of the vertical wall on the drain side.   
					Thisconditionwillnotallowthewalljambofthesteam   
					enclosure to sit flat against the vertical wall.   
					Service Access   
					Service access is through the removable panel. To   
					remove panel, grab the middle of the panel and bow   
					outwards till clips disengage.   
					SERVICE ACCESS PANEL   
					FINISH SURFACE   
					DRAIN   
					TILE FLUSH WITH   
					VERTICAL WALL   
					GRAB PANEL IN MIDDLE   
					AND BOW OUTWARDS   
					To reinstall the panel hold at an angle to the skirt and   
					insert clip under edge of skirt opening. Bow the panel   
					outward and insert clip on other side.   
					If there is a gap between the finish surface and the   
					vertical wall, a filler piece (included with steam enclo-   
					sure) may be required. Gap must not exceed 3/16".   
					Silicone sealant will also be necessary to eliminate any   
					additional gaps that may be present.   
					ACCESS   
					PANEL   
					FINISH SURFACE   
					DRAIN   
					BOW ACCESS   
					PANEL OUTWARD   
					FROM CENTER   
					SHELL   
					TILE NOT FLUSH WITH   
					VERTICAL WALL   
					3/16"   
					MAXIMUM   
					GAP   
					VERTICAL WALL   
					Clean-Up After Installation   
					To avoid dulling and scratching the surface of the   
					shower base, never use abrasive cleaners. A mild liquid   
					detergent and warm water will clean soiled surfaces.   
					Remove spilled plaster with a wood or plastic edge.   
					Metal tools will scratch the surface. Spots left by plaster   
					or grout can be removed if lightly rubbed with detergent   
					on a damp cloth or sponge.   
					Paint, tar, or other difficult stains can be removed with   
					paint thinner, turpentine, or isopropyl alcohol (rubbing   
					alcohol).   
					Minor scratches which do not penetrate the color   
					finish can be removed by lightly sanding with 600-grit   
					wet/dry sandpaper. You can restore the glossy finish to   
					the acrylic surface of the shower base with a special   
					compound, Meguiar's #10 Mirror Glaze. If that is not   
					available, use automotive rubbing compound followed   
					by an application of automotive paste wax.   
					Major scratches and gouges which penetrate the   
					acrylic surface will require refinishing. Ask your Jacuzzi   
					Whirlpool Bath dealer for special instructions.   
					9 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Operation   
					The digital control features an adjustable 60 minute time and temperature control with digital display. The actual   
					room temperature and time remaining are alternately displayed every 5 seconds. The temperature can be adjusted   
					in a range between 100 degrees and 125 degrees Fahrenheit with an initial default of 120 degrees. Once the set   
					temperature is reached the ‘’soft steam’’ feature automatically engages cutting steam production back to a single   
					element. If the steam room temperature drops more than 5 degrees both elements will automatically engage.   
					Operation of Your Digital Time and Temperature Control   
					1. Be sure the power circuit and water supply to the generator are on.   
					2. Press the ON/OFF button on the control until the temperature is displayed.   
					3.Thegeneratorshouldproducesteamin5to10minutesandwillturnoffautomaticallyin60minutesorlessdepending   
					on the set time. The control will alternately display time remaining and the actual temperature at the sensor in your   
					steam room every 5 seconds.   
					4. To change the time setting press and hold the TIME button on the control. Continuing to hold the button will cause   
					the time to increase in 5 minute increments from the prior setting. At 60 minutes the time setting will scroll backwards   
					to 5 minutes. To shut down the generator press the ON/OFF button.   
					5. To change the preset temperature setting press and hold the TEMP button on the control. While continuing to hold   
					the button, the temperature display will increase in 1 degree increments from the prior setting to 125 degrees   
					Fahrenheit. At 125 degrees Fahrenheit the temperature setting will decrease in 1 degree increment to the lowest   
					setting, 100 degrees Fahrenheit.   
					6. The TIME and TEMP set points are remembered for your next bath unless power to the steam generator is lost.   
					Maintenance of the SteamPro Unit   
					Maintenance of the SteamPro includes flushing and visually inspecting for water leaks.   
					To remove the unit remove the access panel. Turn off power to the unit and disengage the power cord. Turn the   
					water supply off at the shut off valve and drain the tank (if necessary). Disconnect all plumbing. Cut and discard   
					shipping restraint. Remove 2 screws holding mounting bracket to wood plank. Slide unit toward front of base and   
					remove. Thereinstallationisthereverseoftheremovalprocedure. Itisnotnecessarytoreplacetheshippingrestraint.   
					SHIPPING RESTRAINT   
					WATER SUPPLY   
					SHUT OFF VALVE   
					TO STEAM HEAD   
					MOUNTING BRACKET   
					REMOVE SCREWS   
					DRAIN DOWN   
					10   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Troubleshooting   
					There are no user serviceable parts in the Generator. All repair should be performed by a qualified service person.   
					For additional assistance or the factory authorized service person nearest you call the Service Department at 1-800-   
					363-0251 (This number is only for service for the steam generator.). The Trouble Shooting Guide below is meant as   
					a general aid only. Follow ACTION TO BE TAKEN in order until the problem is resolved.   
					11   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Troubleshooting   
					12   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Wiring Diagram   
					13   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				PRODUCT SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.   
					USE INSTALLATION INSTRUCTIONS SUPPLIED WITH PRODUCT.   
					Jacuzzi Whirlpool Shower base has obtained applicable code (standards) listings generally available on a national basis for   
					products of this type. It is the responsibility of the installer/owner to determine specific local code compliance prior to installation   
					of the product. Jacuzzi Whirlpool Shower base makes no representation or warranty regarding, and will not be responsible for any   
					code compliance.   
					Jacuzzi Whirlpool Bath National Headquarters   
					P.O. Drawer J, Walnut Creek, CA 94596 (925) 938-7070   
					Service Support: Call (800) 288-4002   
					©2002 Jacuzzi Whirlpool Bath T87100B 2/04   
					Printed on Recycled Paper   
					Printed in the U.S.A.   
					14   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Jacuzzi Whirlpool Bath Limited Warranty   
					Steam Generator Products   
					Jacuzzi Whirlpool Bath, warrants that its Steam Generators (warranted products) are free of manufacturing defects   
					both as to workmanship and material for 5 years and it will replace or repair defective parts or equipment for the period   
					of time and in accordance with the conditions set forth below. The terms of the warranty will be administered by   
					Saunatec Inc. dba, AMEREC.   
					1. Applicability. This warranty applies when the warranted product (a) is installed in accordance with installation   
					instructions provided, (b) is properly and reasonably maintained, and (c) has not been subjected to damage, misuse,   
					or abuse.   
					2. Registration. This warranty becomes valid only after the Limited Warranty Registration form, provided with this   
					warranty, iscompletelyfilledinandsignedbytheoriginalpurchaserandmailedtoAMERECwithinsixty(60)daysfrom   
					the date of original installation. This warranty is nontransferable and shall extend only to the original purchaser.   
					3. Duration of Warranty. AMEREC or it’s authorized representative will provide parts to replace those with   
					manufacturing or workmanship defects for a period of five (5) years from the date of original installation, except when   
					the warranted product is installed in commercial locations such as clubs, condominiums, apartments, spas or military   
					facilities. In commercial locations, AMEREC or its authorized representative will provide parts to replace those with   
					manufacturing or workmanship defects for a period of one (1) year from the date of original installation. Additionally,   
					for noncommercial locations in the United States AMEREC or its authorized representative will provide reasonable   
					labor to replace defective parts for a period of two (2) years from the date of original installation and three   
					(3) additional years if the product is returned to the factory.   
					4. Warranty Work. All warranty work must be (a) authorized by AMEREC before it is performed; and (b) performed   
					only by authorized AMEREC representatives. This warranty shall not apply to any charges for parts or labor incurred   
					before receiving approval by AMEREC.   
					5. Return Authorization Number. A return authorization number assigned by an AMEREC representative must   
					accompany all returned parts. Parts which are returned without a return authorization number may not be repaired   
					or replaced.   
					Jacuzzi Whirlpool Bath   
					C/O AMEREC   
					P.O. Box 2258   
					Woodinville WA, 98072   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				6. Procedure. Requests for repair or replacement, a return authorization number, or warranty information should be   
					directed to AMEREC by calling toll-free 1-800-363-0251 or by writing to AMEREC, 17683 128th Place N.E.,   
					Woodinville, WA 98072. Defective product or parts returned for repair or replacement must be shipped prepaid to   
					AMEREC at the above address. Shipping costs for return of replacement product or parts to the purchaser will be at   
					the expense of the purchaser.   
					7. Limitations, Exclusions, and Remedies. There are no warranties which extend beyond the descriptions on the face   
					hereof. This limited warranty is in lieu of all warranties, expressed or implied, and of all other obligations or liabilities   
					on the part of Jacuzzi Whirlpool Bath. There shall be no implied warranty of merchantability. Jacuzzi Whirlpool Bath   
					neither assumes nor authorizes any person to assume for it any other obligation or liability in connection with the sale   
					of its products. Damages for breach of this warranty shall not exceed the lesser of the cost of repair or replacement.   
					Repair or replacement shall be the exclusive remedy available to the purchaser.   
					Under no circumstances shall Jacuzzi Whirlpool Bath be liable by virtue of this warranty or otherwise for any special,   
					indirect, secondary, incidental, or consequential damage of any nature to any person or property arising directly or   
					indirectly out of the use or inability to use a warranted product.   
					Some States do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental   
					or consequential damages, so the above limitations and exclusions may not apply to you.   
					8. Disputes. Any lawsuit alleging breach of this limited warranty shall be commenced within one year from the date   
					of breach. In addition, any such lawsuit may be commenced only in King County, Washington.   
					This warranty gives you specific legal rights, and you may also have other rights which vary from State to State.   
					LIMITED WARRANTY REGISTRATION FORM   
					Please fill out and return within 60 days of installation to:   
					AMEREC, P.O. Box 2258, Woodinville WA 98072   
					The undersigned hereby acknowledges the receipt of Jacuzzi Whirlpool Bath Limited Warranty and affirms that the   
					date of installation was_____________________20____, further that installation of the equipment has been   
					completed according to the Jacuzzi Whirlpool Bath installation instructions furnished with the equipment and that I   
					have read, understand and agree to the conditions and terms of the Jacuzzi Whirlpool Bath Limited Warranty in its   
					entirety.   
					Name of Purchaser ___________________________________________________________________   
					Address ______________________ City__________________ St. ___________________ Zip _____   
					Phone _____________________________________________________________________________   
					Purchaser’s Signature _________________________________________________________________   
					Model No. & Serial No. ________________________________________________________________   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Jacuzzi Whirlpool Bath Limited Warranty   
					Builder Group Bath Product   
					WARRANTY COVERAGE   
					Jacuzzi Whirlpool Bath (the “Company”) offers the following express limited warranty to the original purchaser of any Jacuzzi Whirlpool Bath Builder Group   
					Bath Product (“unit”) who purchases the product for personal or single family use (“user”). The Company will repair or replace, at its option, the unit or its   
					equipment in accordance with the following terms and conditions.   
					ONE YEAR LIMITED WARRANTY ON BATHS   
					Our warranty on Builder Group Bath products is for one (1) year. Our warranty covers the unit and factory-installed components (e.g., pump, motor)   
					against defects in material or workmanship. Warranty coverage begins on the date the unit was originally purchased by the user.   
					NINETY DAY (PARTS ONLY) LIMITED WARRANTY ON OPTIONS AND ACCESSORIES   
					Our warranty on options and accessories manufactured by the Company is for ninety (90) days for parts only. Our warranty covers options and accessories   
					manufactured by the Company (e.g., fill spout kits, trim kits, skirts) against defects of material or workmanship. Warranty coverage begins on the date the option   
					or accessory was originally purchased by the user.   
					WARRANTY LIMITATIONS   
					Our warranty does not cover defects, damage, or failure caused by the common carrier, installer, user, or other person, or resulting from, without limitation,   
					any of the following: careless handling (lifting unit by plumbing, abrading finish, etc.) including its own negligence; modification of any type for any reason   
					(including modification to meet local codes); improper installation (including installation not in accordance with instructions and specifications provided with   
					the unit); connections supplied by the installer of the equipment; improper voltage supply or unauthorized electrical modification; misuse; incorrect operation,   
					or lack of proper routine maintenance; operation of the unit without specified minimum amount of water or at inappropriate water temperature; use of abrasive   
					or improper cleaners; or acts of God, such as lightning, floods, earthquakes, etc.   
					In addition, THE COMPANY WILL NOT BE RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES or losses arising from any cause   
					(e.g., water damage to carpet, ceiling, loss of use, etc.) including its own negligence; damages to, respecting, or resulting from: plated parts when pool and/or spa   
					chemicals are used in the unit; optional bath equipment not manufactured by the Company, supplied by Dealer, installer or the Company; the unit's prior usage   
					as an operational display; or defects that should have been discovered before installation. This limited warranty does not include: labor, transportation, or other   
					costs incurred in the removal and/or reinstallation of the original unit and/or installation of a replacement unit; any costs relating to obtaining access for repair;   
					or loss of use damage, including loss of sales, profit or business advantage of any kind under any circumstances. Bath units in commercial use are excluded from   
					any warranty coverage if any addition, deletion, or modification of any kind whatsoever has been made to the unit (or to any component).   
					Warranty coverage is provided in the United States of America and Canada.   
					IMPLIED WARRANTIES   
					Implied warranties of merchantability and fitness for a particular purpose are disclaimed altogether or to the full extent allowed by law.   
					NOTICE: This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. There are no warranties applicable   
					to Jacuzzi Whirlpool Bath products except as expressly stated herein or as implied by applicable state and federal laws. The Company will not be responsible for   
					any statements or representations made in any form that go beyond, are broader than or are inconsistent with any authorized literature or specifications furnished   
					by the Company.   
					Some states do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so the above   
					limitations and exclusions may not apply to you.   
					RETURN OF WARRANTY CARD   
					The attached Warranty Registration Card MUST be filled out by the purchaser within thirty (30) days from purchase and mailed to Jacuzzi Whirlpool Bath   
					in order for this warranty to become effective.   
					Jacuzzi Whirlpool Bath   
					P.O. Drawer J   
					Walnut Creek, CA 94596-9885   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				RESPONSIBILITIES OF OTHERS   
					Inspectingtheunitpriortoinstallationistheresponsibilityoftheinstallerorbuildingcontractorwhoactsonbehalfoftheuser.Theyareresponsibleforensuring   
					the unit is free of defect or damage. Notices are placed on and in the unit and on the shipping carton advising the installer of this responsibility. In the event of   
					a problem, the unit must not be installed. The Company is not responsible for failures or damage that could have been discovered, repaired, or avoided by proper   
					inspection and testing prior to installation.   
					Damage occurring in transit is the responsibility of the carrier. The user or installer MUST open the crate and inspect the unit for damage when it is delivered.   
					If damage is discovered, it must be reported immediately to the seller and the carrier in writing, and an inspection requested. Failure of the carrier to respond should   
					be reported to the seller and the carrier. Your freight claims should be filed promptly thereafter.   
					It is the responsibility of the installer, building contractor, or user to provide access for service. The Company is not responsible for any costs relating to   
					obtaining access for repair. The user shall bear such costs and, if appropriate, must seek recovery from the installer.   
					Damage occurring to the unit during installation is the responsibility of the installer and/or building contractor and damage occurring thereafter is the   
					responsibility of the user.   
					Failure of any optional equipment is the sole responsibility of the equipment manufacturer. (Options and accessories manufactured by the Company are   
					warranted for ninety (90) days from the original date of purchase for parts only.)   
					The Distributor or Dealer is responsible for knowing local code requirements and notifying the installing contractor and/or user of these requirements at the   
					time of purchase. The Company is not responsible for costs to modify any product to obtain any code approval, such as city, county, or state building codes in   
					U.S.A. or municipal or provincial codes in Canada.   
					WARRANTY SERVICE   
					For the customer's benefit, the Company maintains a list of independent service personnel to perform required warranty service repairs. Such firms are not agents   
					or representatives of the Company and cannot bind the Company by words or conduct.   
					The Company will provide the warranty service described above when the following conditions have been met: the failure is of the nature or type covered   
					by the warranty; the user has informed an Authorized Jacuzzi Whirlpool Bath Service Agent or Warranty Service Department Representative of the nature of the   
					problem during the warranty period; conclusive evidence (e.g., proof of purchase or installation) is provided to the foregoing by the user proving that the failure   
					occurred or was discovered within the warranty period; an authorized independent service person or Company representative has been permitted to inspect the   
					unit during regular business hours within a reasonable time after the problem was reported by the user.   
					Inordertoobtainwarrantyservice,consultyourlocaltelephonebookforthelocationofthenearestJacuzziWhirlpoolBathAuthorizedServiceAgent.Describe   
					the problem and the Authorized Service Agent will inspect the unit and provide the required warranty service.   
					If you are unable to contact a Jacuzzi Whirlpool Bath Authorized Service Agent, call or write:   
					Jacuzzi Whirlpool Bath   
					Warranty Service Department   
					P.O. Drawer J   
					Walnut Creek, California 94596   
					Call: (800) 288-4002   
					To obtain warranty replacement for factory-installed components for Company supplied options and accessories manufactured and supplied by the Company,   
					call or write the above. Provide a description of the problem and proof of purchase. You will be instructed how to obtain replacements and where to return, at   
					your expense, the failed component(s), option(s), or accessory(ies).   
					All replacement parts, equipment, and repairs shall assume the remaining warranty period of the part(s) replaced.   
					The Company's warranty obligation shall be discharged upon tender of replacement or repair. The customer's refusal to accept the tender terminates the   
					Company's warranty obligation.   
					©2002 Jacuzzi Whirlpool Bath T871000B 2/04   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 |