COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS
SmartPocket™ Optical Power Meters
OLP-34/35/38
• Cost-effective, rugged high-performance solution
• 3-year recalibration period
Key Features
• 1 nm incremental universal wavelength settings
• Universal optical interface supports all 2.5 mm with an
option to support 1.25 mm connectors
• Auto λ detection and TwinTest mode
• Internal data storage and optional PC download capability
• Quick start operation eliminates warm-up
Applications
The JDSU SmartPocket OLP-3x series next-generation small, rugged optical power
meters are ideal for quickly, easily, and conveniently measuring optical power level
and loss in fiber networks from the field. The instruments’ rugged ergonomic
design and large, sharp display show relevant results and settings at the same time.
Their intuitive one-button operation and automatic wavelength recognition is
why technicians choose SmartPocket OLPs when they test fiber. SmartPocket
instruments’ unprecedented data storage capacity for saving up to 100 results and
optional micro USB port for downloading results to a PC fulfills all of your testing and
reporting needs.
• Measure optical power levels and
link insertion loss
• Enterprise LAN networks
with 850/1300 nm multimode
wavelengths capability
• Test access and metro (LAN/WAN)
networks in multimode and single-
mode
• Standard and high-power level
tests for use in telecom, CATV, and
military applications
WEBSITE: www.jdsu.com
Download from Www.Somanuals.com. All Manuals Search And Download.
SMARTPOCKET OLP-3x SERiES OPTiCAL POwER METERS
3
Specifications
Technical
OLP-34
OLP-35
OLP-38
Detector type
Germanium
Universal 2.5 mm/1.25 mm1
InGaAs
Filtered InGaAs
Universal 2.5 mm/1.25 mm1
Optical interface/connectors
Wavelength range
Universal 2.5 mm/1.25 mm1
780 to 1600 nm
780 to 1650 nm
780 to 1650 nm
Wavelength settings
Programmable wavelengths
Calibrated wavelengths
780 to 1600 nm, in 1 nm steps
5 presets (customized)
850, 980, 1300, 1310,
1490, 1550 nm
780 to 1650 nm, in 1 nm steps
5 presets (customized)
850, 980, 1300, 1310,
1490, 1550, 1625 nm
–65 to +10 dBm
–65 to +13 dBm
+16 dBm
780 to 1650 nm, in 1 nm steps
5 presets (customized)
850, 980, 1300, 1310,
1490, 1550, 1625 nm
–50 to +26 dBm
–50 to +26 dBm
+27 dBm
Power range
–60 to +5 dBm
Display range
–60 to +10 dBm
+13 dBm
Max. input power
Measurement units
Absolute uncertainty2
Linearity3
dB/dBm/W
dB/dBm/W
dB/dBm/W
0.2 dB ( 5%)
0.2 dB ( 5%)
0.2 dB ( 5%)
0.06 dB (–50 to +5 dBm)
270 Hz, 1 kHz, 2 kHz
Yes
0.06 dB (–50 to +5 dBm)
270 Hz, 1 kHz, 2 kHz
Yes
0.06 dB (–32 to +20 dBm)
270 Hz, 1 kHz, 2 kHz
Yes
Tone detection
Auto λ mode4
Multi λ mode4
TwinTest/serial TripleTest
TwinTest/serial TripleTest
TwinTest/serial TripleTest
Notes:
1. Optional 1.25 mm UPP accessory adapter is available
2. Under these reference conditions: 20 dBm (CW), 1310 nm 1 nm, 23°C 3K, 5 to 75% relative humidity 9 to 50 μm test fiber with ceramic DIN connector
3. –5 to +45°C
4. With JDSU light sources
General
Storage and interface
Data storage
100 results
Data download capability
micro USB interface for PC transfer (option)
Power supply
Dry batteries
Rechargeable batteries
AC operation (optional)
Battery life
2x Mignon (AA) 1.5 V
2x Mignon (AA) NiMH 1.2 V
via micro USB and SNT-505
≥ 200 hr
Automatic power off after 20 minutes
Environmental conditions
EMI/ESD
CE compliant
3 years
–10 to +55°C (+14 to +131°F)
–40 to +70°C (–40 to +158°F)
30 x 80 x 150 mm (1.2 x 3.1 x 5.9 in)
200 g (0.45 lb)
Recommended calibration interval
Operating temperature
Storage temperature
Dimensions (H x W x D)
Weight
Download from Www.Somanuals.com. All Manuals Search And Download.
SMARTPOCKET OLP-3x SERiES OPTiCAL POwER METERS
Ordering Information
Power Meters
Product Number
Description
2302/01
OLP-34 Optical Power Meter
Germanium, +5 dBm with data storage
OLP-35 Optical Power Meter
InGaAs, +10 dBm with data storage
OLP-38 Optical Power Meter
Filtered InGaAs, +26 dBm with data storage
OLP-34 Optical Power Meter*
Germanium, +5 dBm with data storage and USB download capability
OLP-35 Optical Power Meter*
2302/02
2302/03
2302/11
2302/12
2302/13
InGaAs, +10 dBm with data storage and USB download capability
OLP-38 Optical Power Meter*
Filtered InGaAs, +26 dBm with data storage and USB download capability
Each optical power meter includes a 2.5 mm UPP adapter, AA alkaline batteries, operating manual,
neck strap, and a belt bag.
*Includes downloading capability in addition to USB connection cable and a USB memory stick con-
taining reporting software and product documentation.
Optional Accessories
Product Number
FCR-CLN-01
2237/90.02
2302/90.01
2256/90.03
K 807
Description
Fiber Cleaning Consumables kit
NiMH rechargeable batteries, Mignon AA, 1.2 V (2 batteries required)
SNT-505; universal AC power adapter, micro USB connector
UPP adapter for LC, MU (1.25 mm)
USB connection cable
OFS-355 Reporting Software (free download from jdsu.com)
Test & Measurement Regional Sales
www.jdsu.com/test
north america
TOLL FREE: 1 855 ASK-JDSU
1 855 275-5378
latin america
asia pacific
emea
tel: +1 954 688 5660
fax: +1 954 345 4668
tel: +852 2892 0990
fax: +852 2892 0770
tel: +49 7121 86 2222
fax: +49 7121 86 1222
Product specifications and descriptions in this document subject to change without notice. © 2013 JDS Uniphase Corporation
30162955.002.0213 OLP-34-35-38.DS.FOP.TM.AE
February 2013
Download from Www.Somanuals.com. All Manuals Search And Download.
|