Intel® NetStructure™
7110/7115
e-Commerce
Accelerator
Version 2.3
User Guide
A31032-001
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
About this User Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
New in This Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Who Should Use this Book. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
How to Use this Book. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Installing the 7110/7115 Free-Standing or in a Rack . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Rack Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Free-Standing Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Network Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Status Check. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Download from Www.Somanuals.com. All Manuals Search And Download.
Network and Server LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Inline LED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Admin Terminal Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
HyperTerminal§ Paste Operations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
Server and Network LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
Continuing Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Single Server Acceleration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
Multiple Servers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Multiple 7110/7115s and Cascading Processing . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Scalability and Cascading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Spilling and Throttling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Availability. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
Keys and Certificates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7
Exporting a Key/Certificate from a Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10
Apache SSL§. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11
Stronghold§ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12
Importing into the 7110/7115 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12
Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-14
Global Site Certificates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15
Global Site Certificate Paste Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-16
Redirection: Clients and Unsupported Ciphers . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17
Client Authentication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18
Creating a Client CA Certificate using OpenSSL§ . . . . . . . . . . . . . . . . . . . . . . 3-20
SSL Processing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-21
iv
Download from Www.Somanuals.com. All Manuals Search And Download.
Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-21
Automapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-21
Deleting automapping entries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-22
Manual mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-22
Blocking. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23
Specific IP, Specific Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23
Subnet IP, Specific Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-24
All IPs, Specific Port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-24
Delete a Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-25
Failure Conditions, Fail-safe, and Fail-through . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-26
Syntax. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
Scenario 1—Single Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
Procedure for Scenario 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
Automapping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
Manual Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
Scenario 2—Multiple Servers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
Procedure for Scenario 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
Scenario 3—Multiple 7110/7115s, Cascaded. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7
Assumptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7
Procedure for Scenario 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
Scenario 4—Different Ingress and Egress Routers . . . . . . . . . . . . . . . . . . . . . . . . 4-10
Procedure for Scenario 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
Online Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
Command Line Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
User Authentication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
Command Line Prompt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
Abbreviation to Uniqueness. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
Moving the Insertion Point . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4
Command History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4
Cut and Paste . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5
v
Download from Www.Somanuals.com. All Manuals Search And Download.
Command Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6
Command Reference. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-11
Help Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-11
Status Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-11
SSL Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-12
Port Mapping Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-22
Operational Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-25
Remote Management Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-27
Alarms and Monitoring Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-34
Configuration Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-38
Logging Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-44
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
Remote Telnet Sessions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4
Local Serial Console . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4
Remote Console, Telnet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5
Changing the Telnet Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5
Disabling Telnet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6
Remote SSh Sessions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6
Local Serial Console . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6
Remote Console, SSh. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
Changing the SSh Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
Disabling SSh. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8
SNMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8
Standards Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-9
Intel MIB Tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-9
Supported MIBs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-10
Where to find MIB Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-10
Enterprise Private MIB Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-11
Trap Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-16
Standard SNMP Traps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-16
Private Traps in ssl-appliance-mib.my . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-16
Enabling SNMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-17
vi
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifying SNMP Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-18
Community String. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-19
Trap Community String . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-20
Access Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-21
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1
Alarm Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3
ESC: Encryption Status Change Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3
Alarm Modifiers and Messages: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3
RSC: Refused SSL Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4
Alarm Modifiers and Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4
Extended Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4
RSC Alarm CLI Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4
UTL: Utilization Threshold Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-5
Alarm Modifiers and Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-5
Extended Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-6
UTL Alarm CLI commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-6
OVL: Overload Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7
Alarm Modifiers and Messages: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7
Extended Data: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7
OVL Alarm CLI Commands: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-7
NLS: Network Link Status Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8
Alarm modifiers and messages: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8
Extended Data: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8
Alarm Logging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8
Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-13
Monitoring Reports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-13
Report Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-13
Monitoring Reports CLI Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-14
Using Windows§ HyperTerminal§. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2
Using Unix§ ‘cu’ and uuencoded image file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3
vii
Download from Www.Somanuals.com. All Manuals Search And Download.
Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-4
Appendix B: Failure/Bypass Modes
Bypass Button. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-2
Fail-through Switch (Security Level) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-2
Appendix C: Supported Ciphers
Cipher Strength. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-1
SSL Version Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-2
Appendix D: Regulatory Information
Appendix E: Terms and Conditions and Software License
Glossary
Support Services
viii
Download from Www.Somanuals.com. All Manuals Search And Download.
List of Figures
Mounting Bracket Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Wiring Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Front Panel Connectors and LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
7110/7115 in Single Server Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
7110/7115 in Multiple Server Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
7110/7115 Between Router and ITM Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
7110/7115s Between ITM Device and Servers . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Cascaded 7110/7115s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
Single 7110/7115, Single Server Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
Single 7110/7115, Multiple Server Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
Multiple (Cascaded) 7110/7115s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
Installation with Ingress and Egress Routers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
Download from Www.Somanuals.com. All Manuals Search And Download.
F I G U R E S
Intel’s MIB Tree (top level) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-9
Front Panel Connectors, Controls, and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Front Panel Detail: Failure/Bypass Mode Controls and Indicators . . . . . . . . . . . . . B-2
xii
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Congratulations on your choice of the Intel® NetStructure™ 7110/
7115 e-Commerce Accelerator. The processing of secure transactions
through Secure Socket Layer (SSL) can occupy up to 90% of even the
largest servers’ CPU power and can degrade response time
significantly. The 7110/7115 provides a completely transparent way
to increase the performance of Web sites for SSL transactions. The
7110/7115 is positioned in front of the server farm, where it intercepts
SSL transactions, processes them, and relays them to the servers. The
7110/7115 performs all encryption and decryption management in
this environment with a minimum of administrator interaction.
About this User Guide
This User Guide supports the Intel® NetStructure™ 7110 e-Com-
merce Accelerator and the Intel® NetStructure™ 7115 e-Commerce
Accelerator. By default this text refers to the product as “7110/7115.”
Where appropriate, the text refers to “7110” or “7115.” Additionally,
notes in the left-hand margin may be used to distinguish the two prod-
ucts. Illustrations of the command prompt use “Intel 7115>.”
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 1
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
New in This Release
New features in the Intel® NetStructure™ 7110/7115 e-Commerce
Accelerator include:
•
•
•
Improved performance: Threefold increase in SSL connections
processed per second—from 200 to 600 (7115 only)
More certificate mappings: Up to 1000 certificate mappings
supported
Remote Management:
•
•
•
Telnet—standard remote access to the Command Line
Interface (CLI) with new “Console Monitoring” features
SSh—complete, secure CLI access with new “Console
Monitoring” features
SNMP—Includes both Private Enterprise MIB and MIBII
functionality
•
Alarms: The 7110/7115 can be configured to display—at the
administration console or a remote management session (Telnet
and SSh)—autonomous one-line reports of the following
exceptional conditions:
•
•
•
•
•
Encryption status change
Refused SSL connections
Threshold alerts
Overload alerts
Network link status
1-2
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 1
Who Should Use this Book
•
Monitoring: Users can now configure the 7110/7115 to send
periodic multi-status reports to the administration console or a
remote management session (Telnet and SSh). Monitor reports
include such information as:
•
•
•
•
•
•
•
Inline/bypass mode
Failsafe/failthrough mode
CPU status
SSL connections status
Network interface status
Server interface status
Rate of encryption/decryption
Who Should Use this Book
This User Guide is intended for administrators with the following
background:
•
•
•
•
•
Familiarity with networking concepts and terminology.
Basic knowledge of network topologies.
Basic knowledge of networks and IP routing.
Some knowledge of SSL, keys, and certificates.
Knowledge of Web servers.
Before You Begin
7110/7115 setup can be divided into three basic procedures:
•
Physically install single or multiple 7110/7115s with single or
multiple servers.
•
•
Configure your 7110/7115 in the Command Line Interface.
Identify existing certificates or obtain new ones you wish to use
in SSL operations.
1-3
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 1
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
How to Use this Book
The information in this book is organized as follows:
•
Chapter 1: Introduction provides an introduction and overview
of the 7110/7115, and a summary of new features.
•
Chapter 2: Installation and Initial Configuration contains
installation and initial configuration procedures. (This material is
also discussed in the separate Quick Start Guide.)
•
•
Chapter 3: Theory of Operation explains the general principles
behind 7110/7115 operation.
Chapter 4: Scenarios provides examples of 7110/7115
configurations, together with specific procedures for their
implementation.
•
•
Chapter 5: Command Reference explains the Command Line
Interface (CLI), and lists the commands and their functions.
Chapter 6: Remote Management details how you can use Telnet,
Secure Shell (SSH), and SNMP to manage the 7110/7115 from
remote locations.
•
Chapter 7: Alarms and Monitoring explains the ways in which
you can configure the device to report information to you, either
routinely or as a result of abnormal events or conditions.
•
•
Chapter 8: Software Updates provides procedures for obtaining
7110/7115 system software updates.
Chapter 9: Troubleshooting is a table containing symptoms of
problems you may encounter with corresponding likely causes
and remedies.
•
•
•
•
Appendix A: Front Panel diagrams and explains the 7110/7115’s
front panel LEDs, buttons, and connections.
Appendix B: Failure/Bypass Modes explains how the 7110/7115
deals with failure conditions and details the bypass function.
Appendix C: Supported Ciphers lists the supported encryption
ciphers.
Appendix D: Regulatory Information provides information
regarding the 7110/7115’s compliance with applicable
regulations.
1-4
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 1
How to Use this Book
•
•
Appendix E: Terms and Conditions contains the software license
and terms and conditions of user of this product.
Glossary defines terms appearing in this User Guide.
1-5
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 1
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Notes
1-6
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation and Initial
Configuration
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator
installation and initial configuration instructions are in this chapter.
Before You Begin
WARNING: Do not
remove the cover. There
are no user-servicable
parts inside.
Before you begin installation, you need the following:
•
IP address for 7110/7115 (only if you intend to use the Remote
Management)
•
•
IP addresses and ports of servers.
Keys/certificates. See Chapter 3 for information on obtaining
keys and certificates.
•
Network cables, such as straight-through and/or crossover
cables. (Procedures in the section,“Wiring Connections” in this
chapter will identify the types of cables you must use.) If you are
installing the 7110/7115 in a rack, you will also need:
•
•
Phillips screwdriver
Rack-mounting screws
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 2
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Installing the 7110/7115 Free-
Standing or in a Rack
The Intel® NetStructure™ 7110/7115 e-Commerce Accelerator is
physically installed in either of two ways:
•
In a standard 19” rack, cantilevered from the provided mounting
brackets
•
Free-standing on a flat surface with sufficient space for air-flow
Rack Installation
Rack mounting requires the use of the mounting brackets, and all four
of the included Phillips screws.
1. Locate the two mounting brackets and the four screws. (Two
screws for each bracket.)
2. Attach a mounting bracket to each side of the 7110/7115, using
two of the provided screws for each bracket. Use the holes near
the front of the 7110/7115’s sides. The brackets have both round
and oval holes; the flange with round holes attaches to the 7110/
7115, the oval holes to the rack.
Figure 2-1: Mounting Bracket Orientation
2-2
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 2
Installing the 7110/7115 Free-Standing or in a Rack
3. Position the 7110/7115 in the desired space of your 19” rack and
attach the front flange of each mounting bracket to the rack with
two screws each. (Rack-mounting screws are not provided.)
Free-Standing Installation
1. Attach the provided self-adhesive rubber feet to the 7110/7115’s
bottom.
2. Place the 7110/7115 on a flat surface and make sure that there is
adequate airflow surrounding the unit (allow at least one inch of
air space on all sides).
Network Connections
1. Use the “Network Cable Requirements” table near the beginning
of this guide to select and install the the appropriate cables.
NOTE: Never connect
both ports to the same
network segment (e.g., to
the same hub or switch).
Doing so creates a
2. Connect the provided power cable to the back of the unit. (There
is no power switch.) Under normal circumstances, the 7110/7115
requires approximately 30 seconds to boot. When the boot is
complete, the unit’s Power LED is steadily illuminated. (If the
Power LED is not steadily illuminated, see Chapter 9,
“Troubleshooting.)
feedback loop that
adversely effects network
bandwidth.
3. If the Inline LED is neither steadily illuminated or blinking, press
the Bypass switch.
4. At this point both the Network and Server LEDs should be
steadily illuminated. If not, please see Chapter 9,
“Troubleshooting.
Intel® NetStructure™ 7110/7115 e-Commerce Accelerators
Hub/Router/Switch
Server
Figure 2-2: Wiring Connections
2-3
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 2
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Status Check
Before proceeding to the PC Initialization section, take a moment to
verify that the 7110/7115 is correctly connected.
Network and Server LEDs
Verify that the Network and Server LEDs are both illuminated. If one
or both are not, refer to the Troubleshooting section at the end of this
chapter.
Inline LED
A blinking Inline LED indicates that the system is online in Fail-safe
mode. Refer the Troubleshooting section at the end of this chapter or
Appendix B, “Failure/Bypass Modes.”
Admin Terminal Connection
Run HyperTerminal§ or a similar terminal emulator on your PC. The
steps below are illustrative of HyperTerminal§. Other terminals will
require different procedures.
1. Use the serial cable provided with the 7110/7115 to connect the
device’s serial port (the left-hand serial port labeled “Console”)
to the serial port of any terminal. (A PC running Windows
HyperTerminal§ is used here as an example.)
Power Error Overload Activity
(green) (red) (amber) (green)
Network Link Inline
(green) (green)
Server Link
(green)
Console
Aux Console
Network Link
(RJ45)
Server Link
(RJ45)
Figure 2-3: Front Panel Connectors and LEDs
2-4
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 2
Installing the 7110/7115 Free-Standing or in a Rack
2. Type an appropriate name in the Name field of the Connection
Description window (e.g., “Configuration”), and then click the
OK button. The Phone Number panel appears.
3. In the Connect Using… field specify “Direct to COM1” (or the
serial port through which the PC is connected to the 7110/7115 if
different from COM1).
4. Click the OK button. The COM1 Properties panel appears. Set
the values displayed here to 9600, 8, none, 1, and none.
5. Click the OK button.
HyperTerminal§ Paste Operations
If you’re using Hyperterminal§ you must make the following
configuration change:
1. In the File menu, click Properties.
2. Click the Settings tab.
3. Click the ASCII Setup button.
4. Change the values of Line and Character delay from 0 to at least
1 millisecond.
5. Click OK twice to exit.
2-5
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 2
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Troubleshooting
Server and Network LEDs
If either the Network or Server LED fails to illuminate using either
straight-through or crossover network cables, the problem may be
elsewhere in the network. Verify by wiring around the 7110/7115.
Inline LED
The Fail-through switch allows you to control what happens in the
event of a failure. It is located in a recess between the Network and
Server connectors. Use a small screwdriver or paper clip to
manipulate the switch. The two options are:
•
Allow traffic to flow through the 7110/7115 unprocessed. (Fail-
through mode, indicated by a steadily illuminated Inline LED.)
•
Block traffic flow through the 7110/7115 entirely. (Fail-safe
mode, indicated by a blinking Inline LED.)
Please see Appendix B for a table describing all permutations of LED
operation.
Continuing Configuration
This concludes basic configuration of the 7110/7115. To configure
the unit for production please continue with Chapter 3, Theory of
Operations, or Chapter 4, Scenarios.
2-6
Download from Www.Somanuals.com. All Manuals Search And Download.
Theory of Operation
Security
New in the Intel® NetStructure™ 7110/7115 e-Commerce
Accelerator is Remote Management capability. This feature requires
that the 7110/7115’s network interface be assigned an IP address,
thus security becomes a matter for your attention. If you intend to
manage your 7110/7115 from a remote location, be sure to read the
section “Access Control,” Chapter 6, “Remote Management.”
Single Server Acceleration
Typically, the Intel® NetStructure™ 7110/7115 e-Commerce
Accelerator supports the SSL processing needs of a single server.
This is the simplest and most common configuration. The 7110/7115
is connected to the network between the router and the server.
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 3
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Ideally, the 7110/7115 is located in the same rack as the server,
separated by a short distance. .
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator
Router
Single Server
Figure 3-1: 7110/7115 in Single Server Configuration
Multiple Servers
Given the SSL processing power of the 7110/7115, multiple servers
can be supported. In this configuration, the 7110/7115 sits between
the router and the switch. SSL traffic intended for these servers is
intercepted and other traffic is passed through.
Server 1
Server 2
Router
hub/switch
Server 3
Intel® NetStructure™ 7110/7115
e-Commerce Accelerator
Figure 3-2: 7110/7115 in Multiple Server Configuration
3-2
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 3
Working with Internet Traffic Management (ITM) Devices
Working with Internet Traffic
Management (ITM) Devices
The 7110/7115 is compatible with Internet Traffic Management
(ITM) devices. In such environments, the 7110/7115 lies between the
router and the ITM device, or between the ITM device and the server.
ITM devices distribute workload across multiple servers and redirect
traffic based on content.
Positioning 7110/7115 between ITM
Device and Client Network
If the ITM device supports layer 7 traffic management, URLs must
be readable (that is, unencrypted), thus in environments performing
layer 7 load balancing, it is recommended that the 7110/7115 be
placed between the ITM device and the client network.
Server 1
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator
Server 2
Router
Server 3
Internet
ITM Device
Client
Figure 1-3: 7110/7115 Between Router and ITM Device
3-3
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 3
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Positioning 7110/7115 between ITM
Device and Server
If security considerations require limited network access to clear text,
the 7110/7115 should be placed between the ITM device and the
server.
Intel® NetStructure™ 7110/7115
e-Commerce Accelerators
ITM Device
Router
int l
e
Internet
int l
e
int l
e
Client
Servers
NOTE: The
Figure 1-4: 7110/7115s Between ITM Device and Servers
configuration in Figure
1-4 precludes layer 7
load balancing because
secure traffic through the
ITM device is encrypted.
Multiple 7110/7115s and
Cascading Processing
Scalability and Cascading
The 7110/7115’s capabilities are scalable by chaining, or
“cascading,” multiple 7110/7115s together. In such configurations,
each unit’s server side connector is wired to the network side
connector of the next 7110/7115 in line. The last 7110/7115 in line is
connected to the server, switch, or ITM device.
Spilling and Throttling
When the 7110/7115’s “spill” option is enabled, if a given 7110/7115
cannot process a request within a specified interval, the request is
passed on, still encrypted, to the next 7110/7115 in line. The last
3-4
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 3
Keys and Certificates
7110/7115 on the server side can also be enabled to spill to the server.
Spilling is performed dynamically on a connection-by-connection
basis. (See spill command, Chapter 5, “Command Reference.”) If
spill is disabled, the 7110/7115 “throttles,” that is, will not accept
incoming requests when it becomes overloaded.
Intel® NetStructure™ 7110/7115 e-Commerce
Accelerators
Hub/Router/Switch
Server
Figure 3-5: Cascaded 7110/7115s
Availability
When a 7110/7115 fails or is set to Bypass mode while Fail-through
is enabled, the 7110/7115’s network side and server side network
adapters are directly connected, allowing traffic to pass through to the
next device until the failed unit is brought back into service. This
feature eliminates a single point of failure and provides a high level
of availability, should there be a failure. In installations with multiple
7110/7115s, the next unit in the cascade picks up the encryption/
decryption workload, while in single 7110/7115 configurations, the
server assumes the load. See“Failure/Bypass Modes in Appendix B
for more information.
Keys and Certificates
WARNING: The 7110/
7115 comes with default
keys and certificates for
test purposes, however
certificates for
A necessary part of the 7110/7115 configuration is the use of keys
and certificates. A key is a set of numbers used to encrypt or decrypt
data. A certificate is a “form” that identifies a server or user. The
certificate contains information about your company as well as
information from a third party that verifies your identity.
production use should be
obtained from a
recognized certificate
authority.
3-5
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 3
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
There are three ways to obtain keys and certificates:
•
Obtaining a certificate from VeriSign§ or other certificate
authority
•
•
Using an existing key/certificate
Creating a new key/certificate on the 7110/7115
Cutting and Pasting with HyperTerminal§
Cutting and pasting is an integral part of the next several procedures.
Below are procedures for cutting and pasting in HyperTerminal§. If
you use some other terminal program, consult that product’s
documentation for appropriate procedures.
To copy an item (key, certificate signing request, etc.) from
HyperTerminal§:
1. Open the HyperTerminal§ window.
2. Click and drag to select the item.
3. After the item is selected, open the Edit menu and click Copy (or
type <ctrl-c>).
4. Open the window where you will paste the data, and position the
cursor at the appropriate point.
5. In the Edit menu, click Paste (or type <ctrl-v>).
To paste an item (key, certificate signing request, etc.) into
HyperTerminal§:
1. Display the item in the appropriate application window, then
click and drag to select the item.
2. Once the item is selected, click the Edit menu and select Copy
(or type <ctrl-c>).
3. Move to the HyperTerminal§ window, and position the cursor at
the appropriate point.
4. Pull down the Edit menu, and select Paste to Host (or type
<ctrl-v>).
3-6
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 3
Keys and Certificates
Obtaining a Certificate from VeriSign§
or Other Certificate Authority
Use the create key command to create your key and the create sign
command to create a signing request to be sent to VeriSign or other
certificate authority for authentication. The certificate authority will
return it in approximately one to five days. After you have received
the certificate, use the import cert command to import it into the
7110/7115.
The fields input to create a signing request are called collectively a
Distinguished Name (DN). For optimal security, one or more fields
must be modified to make the DN unique.
Procedure
Create a key:
1. Type the create key command at the prompt:
Intel 7115> create key
Key strength (512/1024) [512]:
New keyID [001]: 002
Keypair was created for keyID: 002
2. Create a Certificate Signing Request:
Intel 7115> create sign 002
You are about to be asked to enter information
that will be incorporated into your
certificate request. The "common name" must be
unique. For other fields, you could use
default values.
Certifying authorities have specific guidelines on how to answer each
of the questions. These guidelines may vary by certifying authority.
Please refer to the guidelines of the certifying authority to whom you
submit your Certificate Signing Request (CSR). Please keep the
following in mind when entering the information that will be
incorporated into your certificate request:
•
Country code: This is the two-letter ISO abbreviation for your
country (for example, US for the United States).
•
State or Province: This is the name of the state or province
where your organization’s head office is located. Please enter the
full name of the state or province. Do not abbreviate.
3-7
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 3
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
•
•
Locality: This is usually the name of the city where your
organization’s head office is located.
Organization: This should be the organization that owns the
domain name. The organization name (corporation, limited
partnership, university, or government agency) must be
registered with some authority at the national, state, or city level.
Use the legal name under which your organization is registered.
Please do not abbreviate your organization’s name and do not use
any of the following characters: < > ~ ! @ # $ % ^ * / \ ( ) ?.
•
•
Organizational unit: This is normally the name of the
department or group that will use the certificate.
Common name: The common name is the “fully qualified
domain name,” (or FQDN) used for DNS lookups of your server
(for example, www.mysite.com). Browsers use this information
to identify your Web site. Some browsers will refuse to establish
a secure connection with your site if the server name does not
match the common name in the certificate. Please do not include
the protocol specifier “http://” or any port numbers or pathnames
in the common name. Do not use wildcard characters such as * or
?, and do not use an IP address.
•
E-mail address: This should be the e-mail address of the
administrator responsible for the certificate.
3. Export the Certificate Signing Request (CSR).
In this example, xmodem is used to send the CSR to a PC connected
to the console port.
Intel 7115> export sign mywebserver
Export protocol: (xmodem, uuencode, ascii)
[ascii]:x <Enter>
Use Ctrl-x to kill transmission
Beginning export...
Export successful!
Intel 7115>
To submit the CSR to a certifying authority, paste it into the field
provided in the authority’s online request form. Remember to include
the “-----BEGIN CERTIFICATE REQUEST-----” and “-----END
CERTIFICATE REQUEST-----” lines.
3-8
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 3
Keys and Certificates
Typically, the CSR will look something like this:
-----BEGIN CERTIFICATE REQUEST-----
MIIBnDCCAQUACQAwXjELMAkGA1UEBhMCQ0ExEDOABgNVBAgT
B09udGFayW8xEDAOBgNVBAcTB01vbnRyYWwxDDAKBgNVBAoT
A0tGQzEdMBsGA1UEAxMUd3d3Lmlsb3ZlY2hpY2tlbi5jb20w
gZ0wDQYJKoZIhvcNAQEBBQADgYsAMIGHAoGBALmJA2FLSGJ9
iCF8uwfPW2AKkyyKoe9aHnnwLLw8WWjhl[ww9pLietwX3bp6
Do87mwV3jrgQ1OIwarj9iKMLT6cSdeZ0OTNn7vvJaNv1iCBW
GNypQv3kVMMzzjEtOl2uGl8VOyeE7jImYj4HlMa+R168AmXT
82ubDR2ivqQwl7AgEDoAAwDQYJKoZIhvcNAQEEBQADgYEAn8
BTcPg4OwohGIMU2m39FVvh0M86ZBkANQCEHxMzzrnydXnvRM
KPSE208x3Bgh5cGBC47YghGZzdvxYJAT1vbkfCSBVR9GBxef
6ytkuJ9YnK84Q8x+pS2bEBDnw0D2MwdOSF1sBb1bcFfkmbpj
N2N+hqrrvA0mcNpAgk8nU=
-----END CERTIFICATE REQUEST-----
4. When the certificate authority returns the certificate, import it
into the 7110/7115. Use the import cert command, with the
KeyID. As with the import key, choose an import protocol for
importing the key. Use p for paste. After the paste is finished, add
three periods to display the command line.
Intel 7115> import cert mywebserver
keyid is mywebserver;
Import protocol: (paste, xmodem, uudecode)
[paste]: <Enter>
Type or paste in date, end with ... alone on line
-----BEGIN CERTIFICATE-----
MIIDKDCCAtKgAwIBAgIBADANBgkqhkiG9w0BAQQFADCBnDEL
MAkGA1UEBhMCVVMxCzAJBgNVBAgTAkNBMQ4wDAYDVQQHEwVQ
b3dheTEaMBgGA1UEChMRQ29tbWVyY2Ug
.
.
.
-----END CERTIFICATE----- <Enter>
... <Enter>
Import successful!
Intel 7115>
3-9
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 3
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
5. Create mapping for Server 1. Use the create map command to
specify the server IP address, ports, and keyID.
Intel 7115> create map
Server IP (0.0.0.0): 10.1.1.30
SSL (network) port [443]: <Enter>
Cleartext (server) port [80]: <Enter>
KeyID to use for mapping: mywebserver
6. Save the configuration when the server has been mapped.
Intel 7115> config save
Saving configuration to flash...
Configuration saved to flash
Intel 7115>
Using an Existing Key/Certificate
Exporting a Key/Certificate from a
Server
This method is used when it is important that the existing keys and
certificates are used.
NOTE: Currently there
is no published method
for extracting private
keys from Microsoft IIS
or Netscape servers.
Consult your server software documentation for detailed instructions
on how to export keys and certificates. Once you have exported the
keys and certificates, use the import key and import cert commands
to paste the keys and certificates into your 7110/7115. Some general
instructions are provided below for the Apache Web Server.
Apache Interface to Open SSL§ (mod_ssl)
For key:
1. Look in $APACHEROOT/conf/httpd.conf for location of *.key
file.
2. Copy and paste the key file.
For certificate:
1. Look in $APACHEROOT/conf/httpd.conf for location of *.crt
file (certificate).
2. Copy and paste the certificate file.
3-10
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 3
Keys and Certificates
Apache SSL§
For key:
1. Look in $APACHESSLROOT/conf/httpd.conf for location of
*.key file.
2. Copy and paste the key file.
For certificate:
1. Look in $APACHESSLROOT/conf/httpd.conf for location of
*.cert file.
2. Copy and paste the certificate file.
3-11
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 3
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Stronghold§
For key:
1. Look in $STRONGHOLDROOT/conf/httpd.conf for location of
*.key file.
2. Copy and paste the key file.
For certificate:
1. Look in $STRONGHOLDROOT/conf/httpd.conf for location of
*.cert file.
2. Copy and paste the certificate file.
Importing into the 7110/7115
1. Use the import key command with the keyID, and choose an
import protocol for importing the key. In this case, use the default
to “paste.” When the paste is finished, add a line break followed
by three periods to display the command line.
Intel 7115> import key mywebserver
Import protocol: (paste, xmodem, uudecode)
[paste]: <Enter>
Type or paste in date, end with ... alone on line
-----BEGIN RSA PRIVATE KEY-----
MIIBOgIBAAJBALGOlBH14vIdtfuA+UnyRIoKya13ey8mj3GD
QakdwoDJALu+jtcC
.
.
.
S9dPdwp6zctsZeztn/ewPeNamz3q8QoEhY8CawEA
-----END RSA PRIVATE KEY-----<Enter>
... <Enter>
Import successful!
Intel 7115>
3-12
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 3
Keys and Certificates
2. Use the import cert command with the keyID. As with import
key, choose an import protocol for importing the key. Use the
default to “paste.” When the paste is finished, add a line break
followed by three periods to display the command line.
Intel 7115> import cert mywebserver
keyid is mywebserver;
Import protocol: (paste, xmodem, uudecode)
[paste]: <Enter>
Type or paste in date, end with ... alone on line
-----BEGIN CERTIFICATE-----
MIIDKDCCAtKgAwIBAgIBADANBgkqhkiG9w0BAQQFADCBnDEL
MAkGA1UEBhMCVVMxCzAJBgNVBAgTAkNBMQ4wDAYDVQQHEwVQ
b3dheTEaMBgGA1UEChMRQ29tbWVyY2Ug
.
.
.
-----END CERTIFICATE----- <Enter>
... <Enter>
Import successful!
Intel 7115>
3. Create a server mapping. Use the create map command to
specify the server IP address, ports, and keyID.
Intel 7115> create map
Server IP (0.0.0.0): 10.1.1.30
SSL (network) port [443]: <Enter>
Cleartext (server) port [80]: <Enter>
KeyID to use for mapping: mywebserver
4. Save the configuration when the server has been mapped.
Intel 7115> config save
Saving configuration to flash...
Configuration saved to flash
Intel 7115>
3-13
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 3
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Creating a new Key/Certificate on the
7110/7115
Use the create key and create cert commands to create new keys and
certificates for 7110/7115 operation. This procedure can be used
when there are no existing keys and certificates on the server. The
advantage is that this method is very fast, but a certificate authority
has not signed the certificates.
The fields input to create a certificate are called a Distinguished
Name (DN). For optimal security, one or more fields must be
modified to make the DN unique.
Procedure
1. Create a key as follows:
Intel 7115> create key
Enter the key strength [512,1024]: 512
New keyID [001]: mywebserver
Keypair was created for keyID: mywebserver
2. Enter the create cert command with the keyID
Intel 7115> create cert mywebserver
You are about to be asked to enter information…
Enter the information for the certificate, as prompted:
•
•
•
•
•
•
•
Country
State
Locality
Organization
Organization unit
Common name (for example, www.myserver.com)
E-mail address.
3. Create a server mapping. Use the create map command to
specify the server IP address, ports, and keyID.
Intel 7115> create map
Server IP (0.0.0.0): 10.1.1.30
SSL (network) port [443]: <Enter>
Cleartext (server) port [80]: <Enter>
KeyID to use for mapping: mywebserver
3-14
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 3
Keys and Certificates
4. Save the configuration when the server has been mapped.
Intel 7115> config save
Saving configuration to flash...
Configuration saved to flash
Intel 7115>
Global Site Certificates
Overview
Four types of certificates are involved in the following discussion:
•
•
Root Certificate. The certificate of a trusted CA such as VeriSign.
Server Certificate. Loaded on the server. Can be either self-
generated or received from a certificate authority such as
VeriSign. Interacts with requesting browser’s root certificate to
establish encryption level.
•
•
Global Site Certificate. An extended server certificate. Allows
128-bit encryption for export-restricted browsers.
Intermediate certificate authority (CA) Certificate. A certificate
“signed,” that is, authenticated, by a recognized certificate
authority such as VeriSign, and used to validate a global site
certificate. Called an “intermediate CA certificate” in the
following discussion.
Export versions of Internet Explorer§ and Netscape§ Communicator
use 40-bit encryption to initiate connections to SSL servers. Upon
receiving a client request, the server responds by sending a digital
certificate. If this certificate is a conventional server certificate (that
is, not a global site certificate), browser and server complete the SSL
handshake and use a 40-bit key to encrypt application data. If the
server responds to a requesting browser with a global site certificate,
the client automatically renegotiates the connection to use 128-bit
encryption.
3-15
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 3
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
A global site certificate is validated by an accompanying intermediate
CA certificate. (Such pairs are called “chained certificates.”)
Examples of intermediate CA certificates include Microsoft SGC
Root§, and VeriSign Class 3§ CA. When a requesting browser
receives a global site certificate along with an intermediate CA
certificate, the browser’s root certificate is used to validate the
intermediate CA certificate, which in turn is used to validate the
global site certificate, thus letting the browser know that it can
renegotiate the connection to use 128-bit encryption.
Global Site Certificate Paste Procedure
If you wish to use a global site certificate, you must import both the
global site certificate and its accompanying intermediate CA
certificate. Both certificates must be chained together in a single file.
Use the import cert command to import either single or chained
certificates. In the latter case, paste the server’s global site certificate
first, followed by the intermediate CA certificate. Follow the
intermediate CA certificate by typing three periods on a new line.
Example:
Intel 7115> import cert <keyID>
Import protocol: (paste, xmodem, uudecode)
[paste]:
Type or paste in data, end with ... alone on line
NOTE: There must be no
white space before,
between, or after
certificates, and the
“Begin...” headers and
“End...” trailers must all
be retained.
-----BEGIN CERTIFICATE-----
MIIFZTCCBM6gAwIBAgIQCTN2wvQH2CK+rgZKcTrNBzANBgkq
hkiG9w0BAQQFADCBujEfMB0GA1UEChMWVmVyaVNpZ24gVHJ1
c3QgTmV0d29yazEXMBUGA1UECxMOVmVyaVNpZ24sIEluYy4x
MzAxBgNVBAsTKlZlcmlTaWduIEludGVybmF0aW9uYWwgU2Vy
:
dmVyIENBIC0gQ2xhc3MgMzFJMEcGA1UECxNAd3d3LnZlcmlz
aWduLmNvbS9DUFMg
SW5jb3JwLmJ5IFJlZi4gTElBQklMSVRZIExURC4oYyk5NyBW
ZXJpU2lnbjAeFw05
OTExMTEwMDAwMDBaFw0wMDExMTAyMzU5NTlaMIHHMQswCQYD
VQQGEwJVUzETMBEG
-----END CERTIFICATE-----
-----BEGIN CERTIFICATE-----
MIIEMTCCA5qgAwIBAgIQI2yXHivGDQv5dGDe8QjDwzANBgkq
hkiG9w0BAQIFADBfMQswCQYDVQQGEwJVUzEXMBUGA1UEChMO
VmVyaVNpZ24sIEluYy4xNzA1BgNVBAsTLkNsYXNzIDMgUHVi
bGljIFByaW1hcnkgQ2VydGlmaWNhdGlvbiBBdXRob3JpdHkw
HhcNOTcwNDE3MDAwMDAwWhcN
3-16
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 3
Redirection: Clients and Unsupported Ciphers
:
OTk3IFZlcmlTaWduMA0GCSqGSIb3DQEBAgUAA4GBALiMmMMr
SPVyzWgNGrN0Y7uxWLaYRSLsEY3HTjOLYlohJGyawEK0Rak6
+2fwkb4YH9VIGZNrjcs3S4bmfZv9jHiZ/4PC/
NlVBp4xZkZ9G3hg9FXUbFXIaWJwfE22iQYFm8hDjswMKNXRj
M1GUOMxlmaSESQeSltLZl5lVR5fN5qu
-----END CERTIFICATE-----<Enter>
...<Enter>
Import successful!
Intel 7115>
Redirection: Clients and
Unsupported Ciphers
NOTE: The user must
provide the redirect URL
and ensure that it is
available, as well as
define the content of the
redirect page.
When a client that does not support the selected cipher suite attempts
to connect to the 7110/7115, the default behavior is to reject the
connection, resulting in the client system reporting a fatal error.
However, the 7110/7115 allows you to specify a “redirect address”
where you can provide clients with additional information. The set
redirect command allows you to specify a redirect Web address for
any Map ID. The show redirect command displays any redirect
addresses currently configured.
WARNING: If the
Intel 7115> list map
redirect URL causes a
client to access the same
7110/7115 mapping that
invoked the redirection
an infinite loop condition
will occur.
Map
Net Ser Cipher Re- Client
ID KeyID Server IP Port Port Suites direct Auth
== ===== ========= ==== ==== ====== ===== ====
1 default Any
443 80 all(v2+v3) n n
2 sample 10.1.2.5 443 80 med(v2+v3) n n
Intel 7115> set redirect 2
Enter a redirect URL at following prompt
e.g. http://www.e-comm_site.com/weakbrowser.html
Enter redirect URL []:http://www.e-
comm_site.com/cipher_info.html
3-17
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 3
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Intel 7115> list map
Map
Net Ser Cipher Re- Client
ID KeyID Server IP Port Port Suites direct Auth
== ===== ========= ==== ==== ====== ===== ====
1 default Any
443 80 all(v2+v3) n
n
n
2 sample 10.1.2.5 443 80 med(v2+v3) y
Intel 7115> show redirect 2
Redirect URL for map 2 is set: http://www.e-
comm_site.com/cipher_info.html
To disable a redirect URL for a mapping:
Intel 7115> set redirect 2 none
Intel 7115> show redirect 2
Redirect URL for map 2 is not set
Client Authentication
NOTE: The 7110/7115
supports only one root
CA certificate per
By default, the 7110/7115 does not authenticate client identities,
however specific map IDs can be configured to request client
certificates for the purpose of verifying identities. When this feature
is enabled, the 7110/7115 verifies that client certificates are signed by
a known CA. This feature is controlled by the import client_ca
command.
mapping. However,
multiple intermediate CA
certificates per single
mapping are supported.
Example:
First, use the list map command to display the current map IDs and
their configurations including, in the last column, Client
Authentication, enabled (y) or disabled (n).
Intel 7115> list map
Map
Net Ser Cipher Re- Client
ID KeyID Server IP Port Port Suites direct Auth
== ===== ========= ==== ==== ====== ===== ====
1 default Any
443 80 all(v2+v3) n
n
n
2 sample 10.1.2.57 443 80 med(v2+v3) n
3-18
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 3
Client Authentication
Next, import the client CA certificate for Map ID 2.
Intel 7115> import client_ca 2
Import protocol: (paste, xmodem, uudecode)
[paste]: <Enter>
Type or paste in data, end with ... alone on line
-----BEGIN CERTIFICATE-----
MIIDxzCCAzCgAwIBAgIBADANBgkqhkiG9w0BAQQFADCBpDEL
MAkGA1UEBhMCVVMxEzARBgNVBAgTCkNhbGlmb3JuaWExEjAQ
BgNVBAcTCVNhbiBEaWVnbzEUMBIGA1UE
.
.
.
XcCabZcfBRuYcZeUoNrGUl8tD80jp2YNG1vidgLEaD1YCli5
I9/mNrcB25mSfdAR
/08ROTMxm4VKOSA=
-----END CERTIFICATE-----<Enter>
...<Enter>
Verify the import by using the list map command again. Note that the
Client Auth column now shows client authentication for Map ID 2
enabled.
Intel 7115> list map
Map
Net Ser Cipher Re- Client
ID KeyID Server IP Port Port Suites direct Auth
== ===== ========= ==== ==== ====== ===== ====
1 default Any
443 80 all(v2+v3) n
n
y
2 sample 10.1.2.57 443 80 med(v2+v3) n
Clients connecting to “map 2” are required to present a client
certificate signed by the CA whose certificate was imported above. If
they do not present a properly signed certificate, their connection
attempt is refused.
3-19
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 3
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Creating a Client CA Certificate using
OpenSSL§
NOTE: To acquire a
There are software packages available that handle the details of client
copy of OpenSSL§ for
your environment, access
the OpenSSL§ Web site at
www.openssl.org
certificate generation, however, you can implement them manually.
The following example illustrates the appropriate steps using
OpenSSL§:
1. Generate the key pair for the client CA:
openssl genrsa -out ca_key.pem 1024
2. Generate the client CA certificate:
openssl req -new -x509 -config intel.cnf -key
ca_key.pem -days 365 -out ca_cert.pem
NOTE: In this example,
ca_cert.pem is your
trusted CA and signing
certificate
3. Using the import client_ca command, import ca_cert.pem
For each client:
1. Generate a key pair:
openssl genrsa -out key.pem 1024
2. Generate a certificate signing request:
openssl req -new -config intel.cnf -days 365
-key key.pem -out csr.pem
3. Sign the client certificate signing request with the client CA
certificate:
openssl x509 -req -CAcreateserial -CAkey
ca_key.pem -CA ca_cert.pem -days 365 -in csr.pem
-out cert.pem
4. Convert from PEM to PKCS12 format in signed certificate form:
openssl pkcs12 -export -in cert.pem -inkey
key.pem -name "<Client ID>" -out cert.p12
5. Import the output file from step 4, cert.p12, the signed certificate,
into the client browser.
3-20
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 3
SSL Processing
SSL Processing
The Intel® NetStructure™ 7110/7115 e-Commerce Accelerator
handles several SSL protocols, for example, HTTPS (which is the
default). For security purposes, you can block access to specified IPs
or ports (see “Blocking” section). Traffic that is not mapped or
blocked flows through transparently (see “Failure” section).
Supported protocols are listed below. (Ports listed are “well-known”
port assignments. Any available port may be used.)
•
•
•
•
•
•
HTTPS 443 (default)
IMAPS 993
POP3S 995
SMTPS 465
NNTPS 563
LDAPS 636
Mapping
NOTE: The 7110
Keypairs and their associated certificates are referenced by a keyID.
A server is identified by a unique combination of server IP and
network port. Mapping is the process of associating a keyID with a
server (using server IP, network port, and server port). The 7110/
7115 supports two types of mapping:
supports a maximum of
100 mappings, while the
7115 supports up to 1000.
•
•
Automapping
Manual mapping
Automapping
NOTE: Remember to
save the configuration
(with the config save
command) after making
mapping changes.
Automapped entries are identified by a server IP address of zero
(0.0.0.0). When a server IP address of zero is specified, the 7110/
7115 intercepts packets to any server IP address with the matching
network ports. As with any mapping entry, the combination of server
IP address and network port must be unique.
The initial configuration for the 7110/7115 provides an automapping
entry for network port 443 and server port 80. This is associated with
the internally generated default keypair and certificate with the keyID
3-21
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 3
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
of “default.” Under this initial configuration, automapping occurs on
any server with this network port (443) when traffic is routed through
the 7110/7115.
Automapping with user-specified key and
certificate
When a user-specified key and certificate are to be automapped, the
user can replace the initial automapping entry with the create map
command. By specifying the same unique identifier (server IP of
0.0.0.0, and network port of 443 with a user-generated keyID, the
user can overwrite the initial automapping entry. (The key and
certificate may be obtained through any of the methods described
previously in this chapter.)
Automapping with multiple port combinations
The user can specify multiple automapping entries when the network
port is unique. For example, a user might specify, in addition to the
initial network (443) and server (80) port combination, a combination
of network (8010) and server (80) port.
Deleting automapping entries
Any automapping entry can be deleted, but if the initial automapping
is deleted and no other mapping entry is specified, the 7110/7115
automatically recreates the initial automapping entry. Either replace
the initial automapping entry or create another mapping/automapping
entry and then delete the initial automapping entry using the delete
map command.
Manual mapping
The user can create (with the create map command) one or more
mapping entries for individual servers. This is the only way to specify
unique keyIDs for each server. Normally, when manual mapping is
performed, the initial automapping entry is deleted, but this is not a
requirement.
3-22
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 3
SSL Processing
Combining automapping and manual mapping
NOTE: If both manual
mappings and applicable
automappings are
available, the 7110/7115
always uses the manual
mapping.
Any combination of automapping and manual mapping entries, up to
a total of 1000, can be used provided the server IP address and
network port combinations are unique. Several of the scenarios in
Chapter 4 include step-by-step mapping procedures.
Blocking
NOTE: Blocking is
always performed before
mapping.
For security purposes, the 7110/7115 allows the blocking of
particular IP addresses and ports. IP/port combinations can be
blocked on the basis of:
•
•
•
Specific IP, specific port
Subnet of IPs, specific port
All IPs, specific port
Specific IP, Specific Port
To block a specific server IP and specific port combination:
1. Type the create block command.
2. Type the IP address.
3. Press Enter to accept the default IP mask
4. Type the specific port.
5. Press Enter to accept the default port mask.
Example:
Intel 7115> create block
Client IP to block [0.0.0.0]: 10.1.2.1
Client IP mask [0.0.0.0]: 255.255.255.255
Server IP to block [0.0.0.0]: 20.1.2.1
Server IP mask [0.0.0.0]: 255.255.255.255
Server Port to block: 80
Server Port mask [0xffff]:<Enter>
Use the show block command to verify:
Intel 7115> show block
(1) block 10.1.2.1 255.255.255.255 20.1.2.1
255.255.255.255 80 0xffff
3-23
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 3
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Subnet IP, Specific Port
To block a subnet IP, and specific port combination:
1. Type a subnet IP address, using 0 as the final octet. (In the exam-
ple below, all IPs from “10.1.x.x” to “20.1.x.x” are blocked on
port 80.)
2. Type the subnet mask, with 0 indicating the portion of the IP
address to be ignored.
3. Type the specific port.
4. Press Enter to accept the default port mask.
Example:
Intel 7115> create block
Client IP to block [0.0.0.0]: 10.1.2.1
Client IP mask [0.0.0.0]: 255.255.0.0
Server IP to block [0.0.0.0]: 20.1.2.1
Server IP mask [0.0.0.0]: 255.255.0.0
Server Port to block: 80
Server Port mask [0xffff]:<Enter>
Use show block to verify:
Intel 7115> show block
-----------
blocks :
-----------
(1) block 10.1.2.1 255.255.0.0 20.1.2.1
255.255.0.0 80 0xffff
-----------
All IPs, Specific Port
To block a specific port on all IP addresses:
1. Type all zeroes as the IP address to be blocked.
2. Type all zeroes as the IP wildcard mask to be blocked.
3. Type the specific port.
4. Press Enter to accept the default port mask.
3-24
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 3
SSL Processing
Example:
Intel 7115> create block
Client IP to block [0.0.0.0]: <enter>
Client IP mask [0.0.0.0]: <enter>
Server IP to block [0.0.0.0]:<enter>
Server IP mask [0.0.0.0]:<Enter>
Server Port to block: 80
Server Port mask [0xffff]:<Enter>
5. Use the show block command to confirm the block:
Intel 7115> show block
-----------
blocks :
-----------
(1) block
0.0.0.0 0.0.0.0 0.0.0.0 0.0.0.0 80 0xffff
-----------
Delete a Block
The example below illustrates how to delete a subnet block. Type the
delete block command with the block ID (block ID is 1 in the
example):
1. Use the show block command to identify the block to be deleted.
Intel 7115> show block
-----------
blocks :
-----------
(1) block 10.1.2.1 255.255.255.255 20.1.2.1
255.255.255.255 80 0xffff
-----------
2. Use the delete block command followed by the block ID to
delete the block.
Intel 7115> delete block 1
3-25
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 3
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Failure Conditions, Fail-safe,
and Fail-through
During any failure condition of the 7110/7115, unprocessed data
packets can either pass through or not, depending on whether Fail-
safe or Fail-through mode is enabled. The Fail-through switch is by
default in Fail-safe mode, meaning that during a failure no data
packets will pass from one side of the 7110/7115 to the other. For
details, see “Failure/Bypass Modes” in Appendix B.
3-26
Download from Www.Somanuals.com. All Manuals Search And Download.
Scenarios
This section contains scenarios illustrating examples of Intel®
NetStructure™ 7110/7115 e-Commerce Accelerator configurations:
•
•
•
•
Scenario 1: Single server
Scenario 2: Multiple servers
Scenario 3: Multiple 7110/7115s, cascaded
Scenario 4: Different ingress and egress routers
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 4
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Syntax
The CLI uses the following syntax:
Symbol
Significance
Angled brackets (< >)
Straight brackets ([ ])
Angled brackets designate where you type variable parameters.
Choices of parameters appear between straight brackets, separated
by vertical bars.
Braces ({})
Boldface
Optional commands or parameters appear between braces.
Commands shown as they are typed after the CLI prompt appear in
boldface type. (The prompt appears in normal typeface to
distinguish it from the command text.)
Vertical bar ( | )
Separates choices of input parameters within straight brackets.
You can choose only one of a set of choices separated by the
vertical bar. (Do not include the vertical bar in the command.)
4-2
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 4
Scenario 1—Single Server
Scenario 1—Single Server
This scenario describes a typical configuration of a 7110/7115 with
one server, using either automapping or manual configuration/
mapping. This scenario describes the fastest way to get up and
running with a 7110/7115.
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator
Router
Single Server
Figure 4-1: Single 7110/7115, Single Server Installation
Procedure for Scenario 1
Automapping
1. Physically connect the 7110/7115 to the router and to one server.
2. Initiate HTTPS traffic to the server. The 7110/7115 monitors
traffic and uses the initial mapping (with associated default key
and certificate) to decrypt HTTPS traffic and pass clear text
HTTP traffic to the server.
Manual Configuration
1. Perform the installation as described in Chapter 2. Access the
7110/7115 command prompt.
2. Acquire the appropriate keys and certificates following the
procedure in the “Keys and Certificates” section in Chapter 3.
4-3
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 4
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
3. Create a mapping for the server. Use the create map command to
specify the server IP address, ports, and keyID.
Intel 7115>create map
Server IP (0.0.0.0): 10.1.1.30
SSL (network) port [443]: <Enter>
Cleartext (server) port [80]: <Enter>
KeyID to use for mapping: myserver
4. You can delete the default mapping. After the user has manually
created the mapping, the default mapping can be deleted. In this
case, delete MapID number 1. MapID number 2 becomes MapID
number 1 when the default is deleted.
Intel 7115>delete map 1
Intel 7115>list maps
Map
Net Ser Cipher Re- Client
ID KeyID Server IP Port Port Suites direct Auth
== ===== ========= ==== ==== ====== ===== ====
1 myserver 10.1.1.30 443 80 med(v2+v3) n n
Intel 7115>
5. Save the configuration when the server has been mapped.
Intel 7115>config save
Saving configuration to flash...
Configuration saved to flash
Intel 7115>
4-4
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 4
Scenario 2—Multiple Servers
Scenario 2—Multiple Servers
This scenario shows how to configure two or more servers.
Server 1
10.1.1.30
Intel® NetStructure™ 7110/7115
e-Commerce Accelerator
Hub/switch
Router
Server 2
10.1.1.31
Figure 4-2: Single 7110/7115, Multiple Server Installation
Procedure for Scenario 2
1. Perform the installation as described in Chapter 2. Access the
7115 command prompt.
2. Acquire the appropriate keys and certificates following the
procedure in the Keys and Certificates section in Chapter 3.
3. Create a mapping for Server 1. Use the create map command to
specify the server IP address, ports, and keyID.
Intel 7115>create map
Server IP: 10.1.1.30
SSL (network) port [443]: <Enter>
Cleartext (server) port [80]: <Enter>
KeyID to use for mapping: myserver
4-5
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 4
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
4. Create a mapping for Server 2. As in the previous step, use the
create map command to specify the server IP address, ports for
the second server, and the keyID.
Intel 7115>create map
Server IP: 10.1.1.31
SSL (network) port [443]: <Enter>
Cleartext (server) port [80]: <Enter>
KeyID to use for mapping: myserver
5. Use the list map command to view the mapping. (Multiple keys
and certificates can also be imported and each mapped to
individual servers. If you do this, at least one field in the
certificate information—usually the common name—must be
unique.)
Intel 7115> list map
Map
Net Ser Cipher Re- Client
ID KeyID Server IP Port Port Suites direct Auth
== ===== ========= ==== ==== ====== ===== ====
1 default Any
443 80 all(v2+v3) n n
2 myserver 10.1.1.30 443 80 med(v2+v3) n n
3 myserver 10.1.1.31 443 80 med(v2+v3) n n
Intel 7115>
6. After you have manually created a mapping, the default mapping
can be deleted. In this case, delete MapID number 1. MapID
number 2 becomes MapID number 1 when the default is deleted.
Intel 7115>delete map 1
Intel 7115>list map
Map
Net Ser Cipher Re- Client
ID KeyID Server IP Port Port Suites direct Auth
== ===== ========= ==== ==== ====== ===== ====
1 myserver 10.1.1.30 443 80 med(v2+v3) n n
2 myserver 10.1.1.31 443 80 med(v2+v3) n n
Intel 7115>
7. To configure a third or fourth web server to operate with the
7110/7115, repeat the steps above, specifying a different IP
address for each server.
4-6
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 4
Scenario 3—Multiple 7110/7115s, Cascaded
8. Save the configuration when mapping is completed for the
server(s).
Intel 7115>config save
Saving configuration to flash...
Configuration saved to flash
Intel 7115>
Scenario 3—Multiple 7110/
7115s, Cascaded
This scenario shows how to cascade 7110/7115s for additional
performance and availability. The same procedures apply that were
performed in Scenario 3. In addition, the complete configuration of
the first 7110/7115 is exported to the second 7110/7115 in line.
Assumptions
•
Two or more 7110/7115s must be physically installed on the
same network. To cascade multiple 7110/7115s, connect from the
server port of the first 7110/7115 to the network port of the next
7110/7115 in line, and then again connect from the server port to
the network port of the next 7110/7115 in line, or to the server.
(See Chapter 2: Installation for more information.)
•
•
On the first 7110/7115, the set spill enable command is used to
enable spilling so that the next 7110/7115 in line can handle the
overflow. Spill is then enabled for each subsequent 7110/7115,
except the last one. Do not configure the last 7110/7115 to spill
to the server.
The first 7110/7115 should be fully configured; any necessary
keys, certificates or maps must exist. The complete configuration
is exported from the first, then imported to the next 7110/7115 in
line. This procedure is repeated for any additional 7110/7115s in
line.
4-7
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 4
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Intel® NetStructure™ 7110/7115
e-Commerce Accelerators
Hub/Router/Switch
Server
Figure 4-3: Multiple (Cascaded) 7110/7115s
Procedure for Scenario 3
1. Configure the 7110/7115 farthest from the server as described in
any of the preceding scenarios. Remain connected to that specific
7110/7115 for the export configuration procedure.
2. At the command prompt, type the set spill enable command.
This allows overflow traffic to be transferred to the second 7110/
7115 for processing.
3. Save configuration.
Intel 7115>config save
Saving configuration to flash...
Configuration saved to flash
Intel 7115>
4. Export the configuration. Use the export config command.
Choose xmodem mode (x) to export.
Intel 7115> export config
Export protocol: (xmodem, uuencode, ascii)
[ascii]: x <Enter>
Beginning export...
5. Select Receive from the HyperTerminal§ Transfer menu.
6. Type or use the Browse button to specify the directory where you
wish to place the received file.
7. Select xmodem as the receiving protocol.
8. Click the Receive button.
4-8
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 4
Scenario 3—Multiple 7110/7115s, Cascaded
9. Specify a filename for the received file and click OK. The
operation concludes and the normal prompt reappears.
Use Ctrl-X to kill transmission
Export successful!
Intel 7115>
10.Connect to the second 7110/7115, either through the console
connection or another window (if both are connected to the same
PC).
11. Import the configuration. Use the import config command to
begin the process. Select xmodem (x) and press Enter to begin
the import process.
Intel 7115> import config
Import protocol: (paste, xmodem, uudecode)
[paste]: x <Enter>
Use Ctl-X to cancel upload
12.Select Send from the HyperTerminal§ Transfer menu.
13.Type or use the Browse button to specify the file to send.
14.Select xmodem as the sending protocol.
15.Click the Send button. The transfer completes and then you are
prompted to verify that you wish to install this configuration.
Do you want to install this config ? [y]: y
16.After verification (y) or refusal (n), the prompt reappears.
Intel 7115>
17.Save the configuration.
Intel 7115>config save
Saving configuration to flash...
Configuration saved to flash
Intel 7115>
18.Repeat steps 11-17 for any additional 7110/7115s. On the last
7110/7115 in the chain, disable spilling with the set spill disable
command.
4-9
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 4
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Scenario 4—Different Ingress
and Egress Routers
This scenario describes the configuration of a 7110/7115 when the
ingress and egress traffic paths are different. This scenario includes:
•
•
One or more servers
One or more 7110/7115s (Multiple commerce accelerators can
be cascaded in this configuration.)
•
•
One or more ingress routers
One egress router
Intel® NetStructure™ 7110/7115
e-Commerce Accelerator
Switch
Ingress Router
Egress Router
Client
Server
Figure 4-4: Installation with Ingress and Egress Routers
Procedure for Scenario 4
NOTE: Execute an “arp
–a” on the server to
display the MAC address
of the default gateway.
This is the address you
should use.
1. Configure your 7110/7115 (as described in any of the previous
scenarios).
2. Determine the MAC address of the egress router you wish to
route outbound traffic through.
3. At the CLI prompt, enter the default egress router.
Intel 7115>set egress_mac 00:11:22:33:44:55
Egress MAC set to 00:11:22:33:44:55
Intel 7115>config save
Saving configuration to flash...
Configuration saved to flash
Intel 7115>
4. To reverse this process:
Intel 7115>set egress_mac none
4-10
Download from Www.Somanuals.com. All Manuals Search And Download.
Command Reference
The Intel® NetStructure™ 7110/7115 e-Commerce Accelerator is
fully configurable through the Command Line Interface (CLI). The
CLI is accessible through the console and aux console RS232 ports.
Online Help
The 7110/7115 provides online help with the following options:
•
•
Type helpto display a summary of commands.
Type help <command> (or ? <command>)for a
description of a specific command or, if relevant, a list of
subcommands you can enter from within <command>.
•
•
Type help usage (or ? <usage>)to display all commands
and their usage.
Type tty_charto display a list of special terminal editing
characters.
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Command Line Interface
The CLI handles all user interactions on the console and auxiliary
console RS232 ports. One instance per port runs at all times.
User Authentication
To gain access to the CLI, the user must first be authenticated by
providing a password at the logon banner prompt. The logon banner
provides build version information and the serial number.
Command Line Prompt
The standard command line prompt for the 7115 is:
Intel 7115>
The prompt for the 7110 is:
Intel 7110>
The prompt can be changed with the set prompt command.
Abbreviation to Uniqueness
It is not always necessary to type the entire command. CLI commands
can be abbreviated to uniqueness. For example, “del” as show below
is sufficient to represent the delete command:
Intel 7115> del
Usage: delete item [arg]
block
cert
blockID
keyID
client_ca mapID
key
keyID
logs
map
logID|all
mapID
patch
permit
sign
permitID
keyID
snmp_community
trap_community
5-2
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Command Line Interface
However, “sh” as shown below, is not an abbreviation to uniqueness
in that it does not distinguish between show and showsnmp.
Intel 7115> sh
The solitary letter “e” in the context of the next example, (i.e.,
preceded by “ssh”), uniquely indicates ssh enable.
Intel 7115> set ssh e
SSH Service started.
5-3
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Input Editing Commands
Moving the Insertion Point
Command
ctrl-b
Description
Move back one character.
Move forward one character.
Move to the start of the current line.
Move to the end of the line.
ctrl-f
ctrl-a
ctrl-e
ctrl-l
Clear the screen and redraw the current line, leaving the current
line at the top of the screen.
Command History
A history of recently executed commands is stored in a buffer and can
be accessed with the following commands:
Command
ctrl-r
Description
(Reverse-search-history) Search backward starting at the current
line and moving up incrementally through the command history.
ctrl-s
(Forward-search-history) Search forward starting at the current
line and moving down incrementally through the command
history.
5-4
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Command Line Interface
Cut and Paste
Command
ctrl-d
Description
Delete the character underneath the cursor.
ctrl-k
Delete the text from the current cursor position to the end of the
line.
ctrl-u
ctrl-w
Delete backward from the cursor to the beginning of the current
line.
Delete the word behind the cursor, using white space as a word
boundary.
ctrl-y
Copy text that has been deleted.
backspace/del
Delete the character to the left of the cursor.
5-5
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Command Summary
This section contains a high-level view of the 7110/7115’s command
structure. Details appear in the next section, Command Reference.
Command
bypass
config
Command Options
save
default
compare
reset
create
delete
block
cert <keyID>
key <keyID>
map
permit
sign <keyID>
block <blockID>
cert <keyID>
client_ca <mapID>
key <keyID>
logs<logID | all>
map <mapID>
patch
permit <permitID>
sign <keyID>
snmp_community
trap_community
exit
export
cert <keyID>
config
key <keyID>
log <logID>
sign <keyID>
factory_default
help
help
help <command>
help usage
5-6
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Command Summary
Command Options
Command
import
cert <keyID>
client_ca <mapID>
config
key <keyID>
patch
upgrade
inline
list
blocks
filters (shows blocks and permits)
keys
logs
maps
monitoring
permits
procs
service
snmp_community
trap_community
nic
password
reboot
5-7
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Command
set
Command Options
alarms <all, esc, rsc, utl, ovl, nls>
cache
ciphers <mapID>
ciphers <mapID> default
client_tmo
date
defcert
egress_mac x:x:x:x:x:x:
egress_mac none
ether
idleto <timeout>
ip <ip> <netmask>
kstrength
max_remote_sessions<1-5>
monitoring <enable | disable>
monitoring_interval
monitoring_fields
more
ovl_window <seconds>
prompt
redirect <mapID>
redirect <mapID> none
route x.x.x.x
rsc_window <seconds>
serial
server_tmo
ssh <enable | disable>
ssh_port
spill <enable | disable>
telnet <enable | disable>
telnet_port <port>
utl_high <percentage>
utl_low <percentage>
utl_window <seconds>
5-8
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Command Summary
Command Options
Command
show
alarms
blocks
cache
cert <keyID>
client_ca <mapID>
client_tmo
config
config default
config saved
date
defcert
egress_mac
ether
filters
idleto
info
ip
key <keyID>
kstrength
logs
map
max_remote_sessions
monitoring
monitoring_interval
monitoring_fields
more
ovl_window
permits
rsc_window
redirect <mapID>
route
serial
server_tmo
ssh
ssh_port
sign <keyID>
spill
status <arg>
telnet
5-9
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Command
show
Command Options
telnet_port
utl_highwater
utl_lowwater
utl_window
setsnmp
snmp <enable | disable>
snmp_community
snmp_port
snmp_info
sys_contact
sys_location
sys_name
trap_authen <enable | disable>
trap_community
trap_port
showsnmp
snmp
snmp_community
snmp_port
snmp_info
sys_contact
sys_location
sys_name
trap_authen
trap_community
trap_port
status
realtime
line
tty_char
5-10
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Command Reference
Command Reference
Help Commands
Command
help
Description
Display the list of available commands.
Display usage for a single command.
Display all commands and their usage.
View the available list of keyboard shortcut commands.
help <command>
help usage
tty_char
Status Command
Command
status
Description
Display device statistics. Several modes are available, as described
below. (Default: realtime.)
Syntax:
Intel 7115> status <arg>
where:
<line> specifies a line-oriented display of statistics.
<realtime> specifies that statistics be displayed in realtime.
<alarms> shows current alarm events.
<log> shows statistics and alarm events in log file.
5-11
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
SSL Commands
Command
create key
Description
Create a new keypair and associate it with a Key ID.
Example:
Intel 7115> create key
Key strength (512/1024) [512]: 1024
New keyID [001]:<Enter>
Keypair was created for keyID: 001.
Intel 7115>
delete key
import key
Delete a specified keypair for a given Key ID.
Syntax:
Intel 7115> delete key <keyID>
where <keyID>is the Key ID whose associated keypair you
wish to delete.
Import a keypair for the specified Key ID.
Syntax:
Intel 7115> import key <keyID>
where <keyID>is the ID of the keypair you wish to import.
5-12
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Command Reference
Description
Command
export key
Export a keypair for a specified Key ID (ASCII, xmodem, or
uuencode).
Syntax:
Intel 7115> export key <keyID>
Export protocol: (xmodem, uuencode, ascii)
[ascii]: <Enter>
Press any key to start, then again when
done...<Enter>
-----BEGIN RSA PRIVATE KEY-----
MIIBOgIBAAJBALqeajCDgfa8fY8FROLi0B8fVp3m4EI
2MpOzKvEKKe6Kk5pDBkH83tUBkssGBtbnDYHkiAyGzA
.
.
.
UFFSNgBRvbkiNvaNiVqKeutwDEhgCL0PDueo
-----END RSA PRIVATE KEY-----<Enter>
Intel 7115>
where <keyID>is the identifier of the keypair you wish to
export.
show key
Display the expanded keypair (including PEM format) for a
specified Key ID. If no Key ID is specified, displays all keys.
Syntax:
Intel 7115> show key <keyID>
where <keyID>is the Key ID whose associated keypair you
wish to view.
list keys
List available Key IDs.
Example:
Intel 7115> list keys
001
default
Intel 7115>
5-13
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Command
create cert
Description
Create a new certificate for a specified Key ID.
Syntax:
Intel 7115> create cert <keyID>
where <keyID>is the Key IDfor which you wish to create a
certificate.
delete cert
import cert
export cert
Delete the certificate associated with a specified Key ID.
Syntax:
Intel 7115> delete cert <keyID>
where <keyID>is the Key ID whose associated certificate you
wish to delete.
Import a certificate to associate with a specified Key ID.
Syntax:
Intel 7115> import cert <keyID>
where <keyID>is the Key ID whose associated certificate you
wish to import.
Export the certificate for a specified Key ID.
Syntax:
Intel 7115> export cert <keyID>
where <keyID>is the Key ID whose associated certificate you
wish to export.
5-14
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Command Reference
Description
Command
show cert
Display the expanded certificate (including PEM format)
associated with a specified Key ID. If no Key ID is specified,
displays all certificates.
Syntax:
Intel 7115> show cert <keyID>
where <keyID>is the Key ID whose associated certificate you
wish to view.
set ciphers
Establish the list of ciphers and cipher strengths that will be
recognized by the specified Map ID.
Syntax:
Intel 7115> set ciphers <mapID>
1 - all
2 - high
3 - medium
4 - low
5 - export only
6 - Customized Ciphers
Select cipher strength [1]: 1
1 - SSLv2
2 - SSLv3
3 - SSLv2 and SSLv3
Select ciphers from SSL version [3]: 2
Intel 7115>
where mapIDis the identifier of the mapping whose ciphers you
wish to set.
5-15
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Command
Description
set redirect
Set an alternative address to which a client is directed in the event
it doesn’t support the specified Map ID’s selected cipher suites.
Syntax:
Intel 7115> set redirect <mapID> [none]
Enter redirect URL []: <URL>
where <mapID>is the Map ID for which you wish to define a
redirect URL, and <URL>is the Web address to which you wish
to redirect clients that don’t support the selected cipher suites.
Enter the optional parameter [none]to disable an existing
redirect URL for the specified Map ID.
show redirect
Displays the alternative address, if one is configured for the
specified Map ID, to which a client is directed in the event it
doesn’t support the selected cipher suite.
Syntax:
Intel 7115> show redirect <mapID>
where <mapID>is the Map ID whose redirect URL you wish to
display. If no redirect address is defined, a command line message
informs you of the fact:
Intel 7115> show redirect 1
Redirect URL for map 1 is not set.
Intel 7115>
show client_ca
Displays the expanded client certificate (including PEM format)
associated with the specified Map ID. If no client certificate has
been imported this command displays a message to that effect. If
no Map ID is specified, all client certificates are displayed.
Syntax:
Intel 7115> show client_ca <mapID>
where <mapID>is the mapID number of the key whose imported
client certificate you wish to display.
5-16
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Command Reference
Description
Command
import client_ca
If you wish to authenticate a client, use this command to import
the trusted CA’s certificate. When enabled, clients without
certificates or with invalid certificates are refused connection.
Syntax:
Intel 7115> import client_ca <mapID>
Import protocol: (paste, xmodem, uudecode)
[paste]: <Enter>
Type or paste in data, end with ... alone on
line
(certificate pasted here...)
...
where <mapID>is the mapID number with which the client
certificate will be associated.
delete client_ca
Deletes the client certificate associated with the specified Map
ID.
Syntax:
Intel 7115> delete client_ca <mapID>
where <mapID>is the mapID number whose associated client
certificate you wish to delete.
create sign
Create the signing request for a specified Key ID.
Syntax:
Intel 7115> create sign <keyID>
where <keyID>is the Key ID number of the Key for which you
wish to create a signing request.
5-17
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Command
delete sign
Description
Delete the signing request for a specified Key ID.
Syntax:
Intel 7115> delete sign <keyID>
where <keyID>is the Key ID number of the Key whose signing
request you wish to delete.
export sign
Export signing request (PEM format) for specified Key ID.
Syntax:
Intel 7115> export sign <keyID>
where <keyID>is the Key ID number of the Key whose signing
request you wish to export.
show sign <keyID>
Display expanded signing request (PEM format) for specified
Key ID. If no Key ID is specified, all signing requests are
displayed.
Syntax:
Intel 7115> show sign <keyID>
where <keyID>is the Key ID number of the key whose signing
request you wish to display.
5-18
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Command Reference
Description
Command
set defcert
Set the default certificate creation information. For example,
country, state, city, organization, organization unit, issuer name,
and issuer e-mail address. You can change all, some or none of
the fields. Press Enter to accept a default and move to the next
field.
Example:
Intel 7115> set defcert
Country name [US]:
State [California]:
City [San Diego]:
Organization [Intel Corporation]:
Organization unit [Network Equipment
Division]:
Issuer name [www.server.com]:
Issuer email address [[email protected]]:
Make changes [y]: y
Changes applied
Intel 7115>
show defcert
Display the default certificate creation information.
Example:
Intel 7115> show defcert
Country: US
State: California
City: San Diego
Organization: Intel Corporation
Unit: Network Equipment Division
Name: http://www.intel.com/network/services
Email: [email protected]
Intel 7115>
5-19
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Command
Description
set kstrength
Set the default key strength. Usable values are 512 or 1024. The
default value is 512.
Syntax:
Intel 7115> set kstrength <512 | 1024>
where <512> allows you to specify low key strength and
<1024>allows you to specify high key strength.
show kstrength
set client_tmo
Display the default key strength value.
Example:
Intel 7115> show kstrength
Default key strength: 512
Interval that the connection between the client and server can
remain idle (i.e., no data crosses the connection in either
direction) following a client request.
Syntax:
Intel 7115> set client_tmo <n>
where <n> is a value in seconds between 5 and 36000.
Displays the currently specified client timeout value.
show client_tmo
Example:
Intel 7115> show client_tmo
Client timeout is 5 seconds
Intel 7115>
5-20
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Command Reference
Description
Command
set server_tmo
Limits the period of time to establish a connection with the server.
If the connection is not established within the specified time, the
client request is rejected.
NOTE: Typical causes for server timeout include: server
powered off, server not accessible, application is not available on
the specified port.
Syntax:
Intel 7115> set server_tmo <n>
where <n> is a value in seconds between 5 and 36000.
Displays the currently specified server timeout value.
show server_tmo
Example:
Intel 7115> show server_tmo
Server timeout [secs]: 5
Intel 7115>
5-21
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Port Mapping Commands
These commands are used to execute the operations described in
Chapter 3’s Mapping and Blocking sections.
Command
Definition
create block
Create a block to preclude access to specified IP addresses or
through specified ports. A single IP, a single port, or all ports can
be blocked. If fewer than all ports are to be blocked, you must
repeat the create block command for each one.
Example:
Intel 7115> create block
Client IP to block [0.0.0.0]: 10.1.2.1
Client IP mask [0.0.0.0]: 255.255.0.0
Server IP to block [0.0.0.0]: 20.1.2.1
Server IP mask [0.0.0.0]: 255.255.0.0
Server Port to block: 80
Server Port mask [0xffff]:<Enter>
Intel 7115>
delete block
show block
Delete a block specified by index number. Use show block (see
below) to correlate existing blocks with their numbers.
Example:
Intel 7115> delete block 1
Intel 7115>
Display all existing blocks.
Example:
Intel 7115> show block
--------
blocks :
---------
(1) block 10.1.2.1 255.255.0.0 20.1.2.1
255.255.0.0 80 0xffff
----------
5-22
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Command Reference
Definition
Command
create permit
Create a configuration allowing a specified user access to specified
servers and ports, and/or denying the specified user access to
specified servers and ports.
Example:
Intel 7115> create permit
Client IP to permit [0.0.0.0]:10.1.2.1
Client IP mask [0.0.0.0]:255.255.0.0
Server IP to permit [0.0.0.0]:20.1.2.1
Server IP mask [0.0.0.0]:255.255.0.0
Server Port to permit: 443
Server Port mask [0xffff]:<Enter>
Intel 7115>
delete permit
show permit
Delete a permit specified by index number. Use show permit (see
below) to correlate existing permits with their numbers.
Example:
Intel 7115> delete permit 1
Intel 7115>
Display permits currently in force.
Example:
Intel 7115> show permit
--------
permits :
---------
(1) permit 10.1.2.1 255.255.0.0 20.1.2.1
255.255.0.0 443 0xffff
----------
Intel 7115>
5-23
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Command
create map
Definition
Create a mapping that associates server IP, SSL port, clear text
port, and Key ID.
Example:
Intel 7115> create map
Server IP (0.0.0.0): 1.1.1.1
SSL (network) port [443]: 443
Cleartext (server) port [80]: 8080
KeyID to use for mapping: 4
Intel 7115>
NOTE: The Key ID used with a new mapping must exist prior to
executing create map. Use create key to create a new Key ID. Also,
a certificate must be associated with the key ID prior to using the
mapping. (See Chapter 3 for details.)
delete map <mapID>
Delete a mapping.
NOTE: All MapIDs of a higher number than the one specified for
deletion are decremented by one when this command is executed.
Syntax:
Intel 7115> delete map <n>
where <n>is the Map ID of the mapping you wish to delete.
Display all mappings. (Same as list maps.)
show map
list maps
List all mappings. (Same as show map.)
Example:
Intel 7115> list maps
Map
Net Ser Cipher Re-
Client
ID KeyID Server IP Port Port Suites direct Auth
== ===== ========= ==== ==== ====== ===== ====
1 default Any
2 sample 1.1.2.5 443 80 med(v2+v3) n
443 80 all(v2+v3) n
n
n
Intel 7115>
5-24
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Command Reference
Operational Commands
Command
bypass
Description
Enables bypass mode, in which traffic flows through 7110/7115
without being processed. See Failure/Bypass Modes in Appendix
B for details. See the inline command below for reversing bypass.
WARNING: Do not issue
the bypass command from a
remote management session
(Telnet or SSh). Doing so
will result in an immediate
disconnect from the 7110/
7115.
Example:
Intel 7115> bypass
The LED labeled “inline” on the 7110/7115’s front panel turns off
when bypass is enabled.
NOTE: The 7110/7115 can be placed in bypass mode
simultaneously with the bypass switch and the CLI’s bypass
command. When this occurs, you must use both the bypass switch
and the CLI’s insert command to return the unit to inline mode.
inline
Enables inline mode, in which the 7110/7115 processes traffic
normally. (As opposed to bypass mode, in which traffic may flow
through the device unprocessed.)
Example:
Intel 7115> inline
The LED labeled “inline” on the 7110/7115’s front panel is
illuminated when inline mode is enabled.
NOTE: Other factors may preclude the use of inline mode. See
Failure/Bypass Modes in Appendix B.
5-25
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Command
set spill
Description
Allows you to enable or disable spill mode. “Spill” is used to
offload processing of a request, when the 7115 has reached a
specified queue threshold, to a secondary 7115 or to the server.
Example:
Intel 7115> set spill enable
Verify spill setting with the show spill command:
Intel 7115> show spill
Spill on overload: enabled
Intel 7115>
show spill
reboot
Display spill setting (enabled or disabled).
Example:
Intel 7115> show spill
Spill on overload: disabled
Reboots the 7115.
WARNING: Any configuration changes mede during the current
CLI session will be lost upon rebooting. Refer to the config save
command for details regarding saving configuration changes.
Example:
Intel 7115> reboot
Are you sure you want to reboot [n]: y
System rebooting...done
(System reboots, eventually prompting you for your password.)
5-26
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Command Reference
Remote Management Commands
Command
set ip
Description
Assign an IP address and netmask to the 7115’s network interface
for Telnet and SSh sessions.
CAUTION: The assignment of an IP address introduces security
issues. Please refer to the “Access Control” section of Chapter 6.
NOTE: To disable a currently configured IP, use set ip followed
by none.
Example:
Intel 7115> set ip
Enter IP Address (’none’ to delete)
[10.1.2.124]:
Enter Netmask [255.255.0.0]:
set
Set the maximum allowed number of concurrently running Telnet
and SSh sessions.
max_remote_sessions
Syntax:
Intel 7115> set max_remote_sessions <1-5>
where <1-5>is the maximum number of remote sessions you
wish to allow. Default: 5.
5-27
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Command
set telnet
Description
Enables or disables Telnet sessions. When this command is set to
“enable” and an IP address is assigned to the 7115’s network
interface, you can access the device’s CLI via remote Telnet
session. When disabled, the device refuses Telnet connections. The
console prompts for any missing parameters. Default: disable.
Syntax:
Intel 7115> set telnet enable
Need an IP address to start Telnet service.
Enter IP Address [209.218.240.67]:
10.1.2.124
Need a netmask to start Telnet service.
Enter Netmask [255.255.255.0]:
Optional Default Route to start Telnet
service.
Enter Default Route (’none’ to delete)
[none]:
Telnet Services started.
Intel 7115>
show telnet
Displays current telnet status: enabled or disabled.
Example:
Intel 7115> show telnet
Telnet: Enabled
set telnet_port
Set the port on which Telnet connections are accepted. (Default
port: 23.)
Syntax:
Intel 7115> set telnet_port <port>
where <port>is the number of the port to which Telnet sessions
will connect.
5-28
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Command Reference
Command
Description
show telnet_port
Display the port on which Telnet sessions are currently accepted.
Example:
Intel 7115> show telnet_port
Telnet port: 23
set ssh
Enable or disable Secure Shell (SSh) sessions. When this
command is set to “enable” and an IP address is assigned to the
7115’s network interface, you can access the device’s CLI via
remote SSh session. When disabled, the device refuses SSh
connections. Default: disable.
Syntax:
Intel 7115> set ssh <enable|disable>
show ssh
Display current SSh status: enabled or disabled.
Example:
Intel 7115> show ssh
SSH: Disabled
set ssh_port
Set the port on which SSh connections are accepted. (Default port:
22.)
Syntax:
Intel 7115> set ssh_port <port>
where <port>is the number of the port to which SSh sessions
will connect.
show ssh_port
Display port on which SSh sessions are currently accepted.
Example:
Intel 7115> show ssh_port
SSH port: 22.
5-29
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Command
Description
setsnmp snmp
Enable or disable the SNMP agent. When enabled, you can set
configure SNMP information and parameters (see setsnmp
snmp_info, below) for the 7115. Default: disable.
Syntax:
Intel 7115> setsnmp <enable|disable>
showsnmp snmp
Displays the current status of the SNMP agent: enabled or
disabled.
Example:
Intel 7115> showsnmp snmp
SNMP: Enabled
setsnmp snmp_info
Set the following SNMP information and parameters:
•
•
•
•
•
SNMP port (Default: 161)
SNMP trap port (Default: 162)
Contact person
System name
System location
Example:
Intel 7115> setsnmp snmp_info
SNMP port [161]: 161
SNMP trap port [162]: 162
Contact Person []: support
System Name []: 7115
System Location []:San Diego
5-30
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Command Reference
Description
Command
showsnmp snmp_info Display the currently effective SNMP information and parameters.
Example:
Intel 7115> showsnmp snmp_info
SNMP Port Number
: 161
SNMP Trap Port Number: 162
SNMP System Contact : support
SNMP System Name
: 7115
SNMP System Location : San Diego
System IP Address
System Netmask
Default Route
: 10.1.2.124
: 255.255.255.0
: None
setsnmp
Set SNMP community strings.
snmp_community
Example:
Intel 7115> setsnmp snmp_community
IP []:xxx.xxx.xxx.xxx
Community String []:<string>
list snmp_community
Display currently configured SNMP community strings.
Example:
Intel 7115> list snmp_community
<2> Current Available SNMP Community String(s):
1.) IP:
2.) IP:
0.0.0.0 => String:
public
0.0.0.0 => String: private
delete
Delete SNMP community strings.
snmp_community
Example:
Intel 7115> delete snmp_commmunity
SNMP Community String(s) Deletion.
<2> Current Available SNMP Community String(s):
1.) IP:
2.) IP:
0.0.0.0 => String:
public
0.0.0.0 => String: private
Enter number (1 to 2) to delete (q to quit) [1]: 2
Enter number (1 to 2) to delete (q to quit) [1]: q
5-31
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Command
Description
setsnmp trap_authen
When enabled, the SNMP manager receives traps upon failed
authentication attempts.
Example:
Intel 7115> setsnmp trap_authen <enable|disable>
setsnmp trap_authen
Displays current status of trap authentication trap.
Example:
Intel 7115> showsnmp trap_authen
Trap Authentication: Enabled
setsnmp
Sets SNMP trap community strings.
trap_community
Example:
Intel 7115> setsnmp trap_community
SNMP Trap Community String(s) Setting.
Enter a SNMP Trap Community IP (q to quit): 0.0.0.0
Enter a SNMP Trap Community String (q to quit):
private
Enter a SNMP Trap Community IP (q to quit): 0.0.0.0
Enter a SNMP Trap Community String (q to quit):
public
Enter a SNMP Trap Community IP (q to quit): q
list trap_community
Display SNMP trap community strings.
Example:
Intel 7115> list trap_community
SNMP Trap Community String(s) information.
<2> Current SNMP Trap Community String(s):
1.) IP:
2.) IP:
0.0.0.0 => String: public
0.0.0.0 => String: private
5-32
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Command Reference
Description
Command
delete trap_community Delete SNMP trap community strings.
Example:
Intel 7115> delete trap_community
SNMP Trap Community String(s) Deletion.
<2> Current Available SNMP Trap Community
String(s):
1.) IP:
2.) IP:
0.0.0.0 => String: public
0.0.0.0 => String: private
Enter number (1 to 2) to delete (q to quit) [1]: 2
Enter number (1 to 2) to delete (q to quit) [1]: q
5-33
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Alarms and Monitoring Commands
Command
set alarms
Description
Enable all or a selection of the 7115’s alarms.
Syntax:
Intel 7115> set alarms
<all|esc|rsc|utl|ovl|nls>
where
<all> enables all five of the 7115’s alarms.
<esc> enables the Encryption Status Change Alarm.
<rsc> enables the Refused SSL Connection Alarm
<utl> enables the Utilization Threshold Alarm
<ovl> enables the Overload Alarm
<nls> enables the Network Link Status Alarm
To disable all alarms, use none:
Example:
Intel 7115> set alarms all
Intel 7115> show alarms
Alarms set: esc rsc utl ovl nls
show alarms
Display the list of currently enabled alarms.
Example:
Intel 7115> set alarms none
Intel 7115> show alarms
Alarms set:
NOTE: When no alarms are set (i.e., when none is specified in set
alarms), the display shows an empty field.
set rsc_window
Set interval (window) at which the device checks for refused SSL
connections and, if any are detected, issues an RSC Alarm.
(Range: 5-65000 seconds, default: 15)
Syntax:
Intel 7115> set rsc_window <sec>
where <sec> is the number of seconds of the desired interval.
5-34
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Command Reference
Command
Description
show rsc_window
Display current Refused SSL Connections Alarm interval.
Syntax:
Intel 7115> show rsc_window
Check refused SSL connections [secs]: 10
set utl_window
Set interval (window) at which the device checks for exceeded
utilization thresholds (CPU load, Connections per Second, or Total
Open Connections and, if any are detected, issues a Utilization
Threshold Alarm. (Range: 5-65000 seconds, default: 15)
NOTE: The data collected for utilization threshold metrics tends
to be bursty,so a smoothing algorithm is used to prevent continuous
alarms.The utilization window is a user-specified sliding interval
during which data is collected and averaged. Consequently, shorter
intervals are likely to result in some extraneous alarms.
NOTE: See also set utl_highwater and set utl_lowwater, this
section.
Syntax:
Intel 7115> set utl_window <sec>
where <sec> is the number of seconds of the desired interval.
set utl_highwater
Set the Utilization Threshold Alarm high-water value. Expressed
as a percentage, the high-water value represents the highest CPU
utilization, Connections per Second, or Total Open Connections
required to trigger a UTL Alarm. (Range: 2-100%, default: 90)
NOTE: See also set utl_window and set utl_lowwater, this section.
Syntax:
Intel 7115> set utl_highwater <%>
where <%> is the percentage defining the upper threshold of CPU
utilization, Connections per Second, or Total Open Connections
required to trigger a Utilization Threshold Alarm.
5-35
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Command
Description
set utl_lowwater
Set the Utilization Threshold Alarm low-water value. Expressed as
a percentage, the low-water value represents the lowest CPU
utilization, Connections per Second, or Total Open Connections
required to trigger a UTL Alarm. (Range: 2-100, default: 90)
NOTE: See also set utl_window and set utl_highwater, this
section.
Syntax:
Intel 7115> set utl_lowwater <%>
where <%> is the percentage defining the lower threshold of CPU
utilization, Connections per Second, or Total Open Connections
required to trigger a Utilization Threshold Alarm.
show utl_window
Display the current Utilization Threshold Alarm window.
Example:
Intel 7115> show utl_window
Utilization window set [secs]: 10.
show utl_highwater
show utl_lowwater
set ovl_window
Display the Utilization Threshold Alarm’s current upper threshold.
Example:
Intel 7115> show utl_highwater
Utilization High water mark [%]: 80
Display the Utilization Threshold Alarm’s current lower threshold.
Example:
Intel 7115> show utl_lowwater
Utilization Low water mark [%]: 60
Set interval (window) at which the device checks for overloads
resulting in the device executing a spill or throttle and, if any are
detected, issues an Overload Alarm. (Range: 5-65000, default: 15)
Syntax:
Intel 7115> set ovl_window 10
5-36
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Command Reference
Command
Description
show ovl_window
Display the current Overload Alarm window.
Example:
Intel 7115> show ovl_window
Check for overload conditions [sec]: 10
5-37
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Configuration Commands
Command
Description
show config
Display current volatile configuration settings.
Example:
Intel 7115> show config
# default config file created on Tues July 25
06:56:46 2000
(Configuraton parameters are displayed here...)
Intel 7115>
show config saved
Display saved non-volatile configuration settings.
Example:
Intel 7115> show config saved
Saved configuration
===================
(Configuraton parameters are displayed here...)
Intel 7115>
5-38
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Command Reference
Description
Command
show config default
Display default configuration settings. These are values used when
factory default commands are executed.
Example:
Intel 7115> show config default
Default configuration
=====================
conlog 0xffffffef
ilog 0xffffffff
trace 0xfffff3dd
media auto
logport tty01
cache 3
server_tmo 5
client_tmo 30
serverif exp1
netif exp0
map 0.0.0.0 443 80 default
kpanic reboot
monitoring_interval 15
monitoring_fields 0x1F
alarm_mask 0x00000000
ovl_window 15
rsc_window 15
utl_window 15
utl_high 90
utl_low 60
idle 300
kstrength 512
con_speed 9600
con_bits 8
con_stop 1
con_parity n
max_remote_sessions 5
trap_authen 1
defcert_cname US
defcert_state California
defcert_city San Diego
defcert_orgname Intel Corporation
defcert_orgunit Network Equipment Division
defcert_name www.intel.com
defcert_email [email protected]
prompt Intel 7115>
Intel 7115>
5-39
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Command
Description
config compare
Display differences between saved and current configuration. For
optimal flexibility in configuration and testing, the 7115 supports
both “current” (volatile) and “saved” (non-volatile) configurations.
The config compare command displays the differences, if any,
between the two configurations.
Example:
Intel 7115> config compare
Only in /keys: 4
Intel 7115>
config reset
Restore saved configuration (no reboot).
Example:
Intel 7115> config reset
Reverting to saved configuration
Reset (y/n) [n]: n
Intel 7115>
config default
Clears current and saved configurations and restores factory
defaults.
WARNING: Executing this command causes the system to reboot.
Example:
Intel 7115> config default
Reset to factory default configuration [n]: y
Reset to factory defaults
System rebooting...
config save
Save the current configuration to the flash (non-volatile) memory.
Example:
Intel 7115> config save
Saving configuration to flash...
Configuration saved to flash
Intel 7115>
5-40
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Command Reference
Description
Command
export config
Export all configuration, key, sign and certificate information
(ASCII, xmodem, uuencode).
WARNING: Do not edit an
exported configuration file.
Example:
Intel 7115> export config
Export protocol: (xmodem, uuencode, ascii)
[ascii]:
Press any key to start, then again when
done...
# default config file created on Fri Jul 28
06:56:46 2000
(...configuration specifics are displayed...)
Intel 7115>
import config
Import a configuration file (paste, xmodem, uudecode).
Example:
Intel 7115> import config
Import protocol: (paste, xmodem) [paste]:
Type or paste in data, end with ... alone on
line
.
.
.
Do you want to install this config ? [y]: n
Intel 7115>
5-41
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Command
Description
import upgrade
Import a complete software release. (See Chapter 6 for details
regarding software updates.)
Example:
Intel 7115> import upgrade
Import protocol: (xmodem, uudecode)
[xmodem]:
Start xmodem upload now
Use Ctl-x to cancel upload
Verifying upgrade image...
upgrade image valid
version x.x, build xxx
Continue with the upgrade? [n]:y
NOTE: Note, all save logs will be deleted and the system will
reboot upon sucessful completion of the upgrade
import patch
Import a partial software upgrade
Example:
Intel 7115> import patch
Enter patch name [80.patch] <patch name>
Import protocol: (xmodem, uudecode)
[xmodem]:
Start xmodem upload now
Use Ctl-x to cancel upload
Patch: Imported.
list system
Displays the device’s CPU, memory and crypto card information.
Intel 7115> list system
=================================================
SYSTEM INFO
=================================================
* CPU
* Real MEM : 536870912 (512.00 MB)
* Crypto : 3
: Pentium II (498 MHz) GenuineIntel
5-42
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Command Reference
Command
Description
factory_default
Returns to factory configuration settings.
Example:
Intel 7115> factory_default
Reset to default configuration [n]: y
Reset to factory defaults
System rebooting...done
T944 V2.31 DXC.
..
868242+361188O/S running
Generating 512 bit default key
Generating default certificate
Saving default key/cert to flash
Restricted Rights Legend
(...copyright and version information displayed here...)
Serial 0:a0:a5:11:4:9d
password:
5-43
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Administration Commands
Command
password
Description
Set the password.
Example:
Intel 7115> password
Old password:<xxxxx>
Enter new admin password (5 chars min.):<yyyyy>
Retype new password:<yyyyy>
admin Password changed...
Intel 7115>
show info
Display software version information.
Example:
Intel 7115> show info
============================================
=== Intel(R) NetStructure(tm) 7115
e-Commerce Accelerator
=== Copyright (c) 2000 Intel Corporation
=== All rights reserved.
===
=== Version 2.3, Build xxx
============================================
set date
Set the date and time.
WARNING: Execution of this command reboots the 7115.
Example:
Intel 7115> set date
Year [2000]:
Month [2]:
Day [16]:
Hour (24 hour clock) [15]:
Minute [10]:
The system must reboot for changes to take
affect. Reboot [y]: n
Intel 7115>
show date
5-44
Displays current date and time.
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Command Reference
Description
Command
set egress_mac
Allows the configuration of a 7115 when the ingress and egress
traffic paths are different. (See Chapter 4, Scenario 4.)
set ether
Specify ethernet settings.
Example:
Intel 7115> set ether
1 - auto
2 - 10baseT, half duplex
3 - 10baseT, full duplex
4 - 100baseTX, half duplex
5 - 100baseTX, full duplex
Select media type [1]:
Media set to auto
Intel 7115>
show ether
set idleto
Display ethernet settings.
Example:
Intel 7115> show ether
Ethernet media set to auto
Intel 7115>
Set the console idle interval. After <n > minutes absence of
keyboard activity, the user is automatically logged off.
Syntax:
Intel 7115> set idleto <n>
where <n> is a value in minutes.
Display console timeout.
show idleto
Example:
Intel 7115> show idleto
Idle timeout is 5 minutes
Intel 7115>
5-45
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Command
set more
Description
Set the page length of the console display. Default is 300.
Syntax:
Intel 7115> set more <n>
where <n> is the desired number of lines. Valid inputs are 0 (to
disable), or 23 or greater.
nic
Allows you to set the network interface card configuration.
Example:
Intel 7115> nic
1 - auto
2 - 10baseT, half duplex
3 - 10baseT, full duplex
4 - 100baseTX, half duplex
5 - 100baseTX, full duplex
Select media type [1]:
set prompt
set serial
Change the prompt from Intel 7115> to the desired prompt.
Example:
Intel 7115> set prompt
Prompt [Intel 7115> ]: <Enter>
Intel 7115>
Allows user to set the console port to monitor the CLI or the output
logging, and set the speed, data bits, stop bits, and parity bits. The
aux console port is fixed at 115200, 8, 1, N. This command returns
the user to the “password” prompt after setting the console port.
Example:
Intel 7115> set serial
Baud rate (9600/115200) [9600]: <Enter>
Data bits (7/8) [8]: <Enter>
Stop bits (1/2) [1]: <Enter>
Parity (n/e/o) [n]: <Enter>
Set serial parameters [y]: <Enter>
Intel 7115>
5-46
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Command Reference
Command
Description
show serial
Display console serial parameters.
Example:
Intel 7115> show serial
Speed: 9600
Bits: 8
Stop bits: 1
Parity: n
Intel 7115>
exit
Log the user out of the CLI. If the current configuration has
changed, the user is allowed to save the current configuration as
the active configuration.
Example:
Intel 7115> exit
Goodbye
.
.
.
password:
Logging Commands
Command
export log
Description
Export a saved log/trace file.
Syntax:
NOTE: Log files referred
to here are not human-
readable.
Intel 7115> export log <logID>
where <logID>is the ID of the specific log you wish to export.
Example:
Intel 7115> export log a
Export protocol: (xmodem, uuencode)
[xmodem]:
Use Ctrl-X to kill transmission
Beginning export...
5-47
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 5
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Command
delete log
Description
Delete saved log/trace files from /flash/logs.
Syntax:
Intel 7115> delete log <logID> | all
where <logID>is the ID of the specific log you wish to delete,
and alldeletes all logs.
list logs
List all log files.
5-48
Download from Www.Somanuals.com. All Manuals Search And Download.
Remote Management
Overview
The current software release allows you to remotely manage the
7110/7115. Remote management is available via three protocols:
•
•
•
Telnet
Secure Shell (SSh)
SNMP
NOTE: Remote
When enabled, remote management allows you to access the device’s
Command Line Interface (CLI) from Telnet or SSh sessions running
on remotely located machines. Up to five remote sessions can be
configured, including both Telnet and SSh sessions (Default: 5).
Before you can use the device’s remote management function, you
must enable and configure it at the local serial console. Remote
management requires that the device’s network interface be assigned
an IP address, unlike earlier versions of the 7110.
management functions
can be enabled and
configured only through
the local serial console.
Remote SNMP management is supported to the extent of allowing
control of the System group of MIB-II.
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 6
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Limitations
Note that several CLI capabilities available at the local console are
unavailable in remote sessions. These are:
•
Assignment of an IP address to the 7110/7115’s network
interface
•
•
•
•
Enable/disable Telnet, SSh, or SNMP
Change Telnet, SSh, or SNMP ports
Set maximum number of Telnet or SSh sessions
Enable/disable monitoring report or alarms (Though reports and
alarms can be received remotely when these features are enabled
at the serial console prior to enabling remote management.)
The CLI commands that control remote management potentially
affect the device’s configuration files, thus if a remote management
configuration is to persist across a shutdown/startup of the device,
you must follow remote management configuration with the CLI
command config save. This ensures that the configuration will be
restored upon startup.
Remote Management CLI Commands
Remote management is enabled or disabled and configured by using
a series of CLI commands available only at the local serial console.
The exact sequence varies depending on the type and configuration
of the remote session you wish to enable. (Usage is detailed in
subsequent sections.) These commands are:
General:
•
•
set ip <ip> <netmask> assigns an IP address and netmask to the
7110/7115’s network interface.
set max_remote_sessions <1-5> sets the maximum allowed
number of concurrently running Telnet and SSh sessions.
Telnet-specific:
•
•
•
set telnet enable|disable enables or disables Telnet sessions.
show telnet displays current telnet status: enabled or disabled.
set telnet_port <port> sets the Telnet port. (Default: 23.)
6-2
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 6
Overview
•
show telnet_port displays current telnet port.
SSh-specific:
•
•
•
•
set ssh enable|disable enables or disables SSh sessions.
show ssh displays current SSh status: enabled or disabled.
set ssh_port <port> sets the SSh port. (Default: 22.)
show ssh_port displays current SSh port.
SNMP-specific:
•
•
•
setsnmp snmp enable|disable enables or disables SNMP
management.
showsnmp snmp displays current SNMP status: enabled or
disabled.
setsnmp snmp_info sets the following SNMP information and
parameters:
•
•
•
•
•
•
SNMP port (Default: 161)
SNMP trap port (Default: 162)
SNMP agent IP address
Contact person
System name
System location
•
showsnmp snmp_info displays current SNMP information and
parameters.
•
•
•
•
•
•
setsnmp snmp_community sets SNMP community strings.
list snmp_community displays SNMP community strings.
delete snmp_community deletes SNMP community strings.
setsnmp trap_community sets SNMP permission strings.
list trap_community displays SNMP permission strings.
delete trap_community deletes SNMP permission strings.
6-3
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 6
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Remote Telnet Sessions
This section contains procedures for accessing the 7110/7115’s CLI
via remote Telnet session.
Local Serial Console
Assign an IP address to the 7110/7115’s network interface using the
following procedure:
Intel 7115> set ip
Enter IP [10.1.2.56]: 10.1.1.1
Enter Netmask [255.255.255.0]:
Verify the IP and netmask (optional):
Intel 7115> show ip
System IP Address : None
System Netmask
Intel 7115>
: None
Enable remote Telnet sessions:
Intel 7115> set telnet enable
Configure the network route:
Intel 7115> set route
Enter Default Route (’none’ to delete)
[10.1.1.1] : <enter>
Verify the route configuration (optional):
Intel 7115> show route
Default Route : 10.1.1.1
Delete a route configuration (optional):
Intel 7115> set route none
NOTE: To ensure that
this remote management
configuration persists
across a device shutdown
and startup, run the
Remote Telnet management is now enabled and configured on the
7110/7115. Now you can access the CLI from a remote Telnet
session.
config save command.
6-4
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 6
Remote Telnet Sessions
Remote Console, Telnet
With remote Telnet enabled on the 7110/7115, use the following
procedure to access it’s CLI:
Unix-prompt> telnet 10.1.1.1
Trying 10.1.1.1...
Connected to 10.1.1.1.
Escape character is ’^]’.
.
.
.
Serial 0:a0:a5:11:4:2e
password:<password>
NOTE: If other remote
sessions are already
running and the new one
exceeds the number
allowed as configured
with the set
After you enter your password, the Telnet session displays the 7110/
7115’s CLI. From this point, you can manage the device as you would
from the local serial console, minus the few disallowed commands
listed in the “Limitations” section near the beginning of this chapter.
max_remote_sessions
command, the CLI
Changing the Telnet Port
displays the message,
“Max Remote Sesion
Limit of (5) exceeded!”
Either close a session, or
increase the maximum
number allowed.
The Telnet port is set and displayed by using the CLI commands, set
telnet_port <port> and show telnet_port.
These commands are available only at the local serial console and
when the remote management is enabled. By default, the Telnet port
number is 23.
To set the Telnet port:
Intel 7115> set telnet_port 230
To display the Telnet port:
Intel 7115> show telnet_port
Telnet Port Number: 230
6-5
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 6
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Disabling Telnet
Telnet sessions are disabled at the 7110/7115’s local serial console.
To disable, follow the steps below:
Intel 7115> set telnet disable
To verify Telnet disable:
Intel 7115> show telnet
Telnet: disable
To ensure that Telnet sessions remain disabled across a device
shutdown and startup, run the config save command.
Remote SSh Sessions
This section contains procedures for accessing the 7110/7115’s CLI
via remote Secure Shell (SSh) session.
Local Serial Console
Assign an IP address to the 7110/7115’s network interface using the
following procedure:
Intel 7115> set ip
Enter IP [10.1.2.56]: 10.1.1.1
Enter Netmask [255.255.255.0]:
Verify the IP and netmask (optional):
Intel 7115> show ip
System IP Address: 10.1.1.1
System Netmask: 255.255.255.0.
Enable remote SSh sessions:
Intel 7115> set ssh enable
Configure the network route:
Intel 7115> set route
Enter Default Route (’none’ to delete)
[10.1.1.1] : <enter>
6-6
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 6
Remote SSh Sessions
Verify the route configuration (optional):
Intel 7115> show route
Default Route : 10.1.1.1
Delete a route configuration (optional):
Intel 7115> set route none
NOTE: To ensure that
this remote management
configuration persists
across a device shutdown
and startup, run the
Remote SSh management is now enabled and configured on the
7110/7115. Now you can access the CLI from a remote SSh session.
Remote Console, SSh
config save command.
With remote SSh enabled on the 7110/7115, use the following
procedure to access it’s CLI:
Unix-prompt> ssh -1 admin 10.1.1.1
.
.
.
Serial 0:a0:a5:11:4:2e
password:<password>
NOTE: If other remote
sessions are already
running and the new one
exceeds the number
allowed as configured
with the set
After you enter your password, the SSh session displays the 7110/
7115’s CLI. From this point, you can manage the device as you would
from the local serial console, minus the few disallowed commands
listed in the “Limitations” section near the beginning of this chapter.
max_remote_sessions
command, the CLI
Changing the SSh Port
displays the message,
“Max Remote Sesion
Limit of (5) exceeded!”
Either close a session, or
increase the maximum
number allowed.
The SSh port is set and displayed by using the CLI commands, set
ssh_port <port> and show ssh_port.
These commands are available only at the local serial console and
when the remote management is enabled. By default, the SSh port
number is 22.
To set the SSh port:
Intel 7115> set ssh_port 220
6-7
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 6
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
To display the SSh port:
Intel 7115> show ssh_port
SSH Port Number: 220
Disabling SSh
SSh sessions are disabled at the 7110/7115’s local serial console. To
disable, follow the steps below:
Intel 7115> set ssh disable
To verify SSh disable:
Intel 7115> show ssh
SSH: disable
To ensure that SSh sessions remain disabled across a device
shutdown and startup, run the config save command.
SNMP
The Intel® NetStructure™ 7110/7115 e-Commerce Accelerator has
a fully compliant, embedded SNMP agent that supports SNMPv1 and
SNMPv2 requests. In addition to standard MIB-II, Intel private
enterprise MIBs provide the following capabilities:
•
Monitor the health of the 7110/7115’s hardware and network
links
•
•
Monitor the flags used to enable and disable alarms and monitors
Monitor the 7110/7115’s load as indicated by CPU utilization,
connection count, and connections per second
•
•
Monitor status and performance of SSL encryption and
decryption functions
Monitor overloads, spills, and throttles
6-8
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 6
SNMP
Standards Compliance
The 7110/7115 SNMP agent is bilingual and can support both
SNMPv1 and SNMPv2c requests. Intel private enterprise MIB files
are compliant with SMIv2 as specified in RFC 1902. SET operations
are not allowed for any Intel private MIB objects for the 7110/7115,
issued on the CLI.
Intel MIB Tree
Figure 6-1 illustrates the top level of Intel’s MIB tree.
iso.org.dod.internet.private.enterprises (1.3.6.1.4.1)
intel (343)
sysProducts (5)
mib2ext (6)
directors (5)
ns7xx (100)
nstructure7115 (10)
sslApplianceMib (1)
nstructure7110 (1)
Figure 6-1: Intel’s MIB Tree (top level)
6-9
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 6
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
All Intel enterprise MIBs and MIB objects are defined under the
mib2ext branch of the Inteltree. All sysObjectIdsthat identify
Intel products are defined under the sysProductsbranch of the
Intel tree.
Supported MIBs
Management Information Base-II (MIB-II)
Intel Enterprise MIBs:
ceo-header.my
ssl-appliance-mib.my
Where to find MIB Files
Electronic copies of the Intel MIB files used by the 7110/7115 are
shipped with the product on CD-ROM.
Write access through SNMP SET is not allowed for any MIB
variables or SNMP groups. An SNMP SET on any group returns an
error.
The standard SNMP traps, coldStart, warmStart,
authenticationfailure, linkUpand linkDownare
supported.
ceo-header.my
ceo-header.mycontains all the sysObjectIdsdefined for
Intel® NetStructure™ products. All sysObjectIdsare defined
under the sysProducts/directorsbranch of the inteltree.
This MIB file contains the following sysObjectIddefinitions for
the following e-Commerce Accelerator products:
•
•
7110 {343, 5, 5, 1}
7115 {343, 5, 5, 10}
6-10
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 6
SNMP
Enterprise Private MIB Summary
Following is a summary of the 7110/7115 private MIB:
mode
inline(1): Device is configured to accelerate
SSL traffic
bypass(2): Device is configured to pass through
all SSL traffic
failMode
safe(1): Two ethernet segments fail open,
stopping traffic
through(2): Two ethernet segments fail shorted,
allowing traffic to continue
spillMode
throttle(1): Device will throttle SSL
connections when utilization reaches 100%
spill(2): Device will spill SSL connections when
utilization reaches 100%
sslSessionCache
enabled(1): SSL session caching is turned on
disabled(2): SSL session caching is turned off
restarts
Number of times the system has restarted
appLastRestart
The value of sysUpTime at the time the last
restart of the application process happened
encryptionAlarm
enabled(1): Encryption status change alarm is
turned on
disabled(2): Encryption status change alarm is
turned off
sslConnectionAlarm
enabled(1): SSL connection alarm is turned on
disabled(2): SSL connection alarm is turned off
6-11
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 6
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
thresholdAlarm
enabled(1): Threshold alarm is turned on
disabled(2): Threshold alarm is turned off
overloadAlarm
enabled(1): Overload alarm is turned on
disabled(2): overload alarm is turned off
linkStatusAlarm
enabled(1): Network link status alarm is turned
on
disabled(2): Network link status alarm is turned
off
encryptProcessingState
on(1): SSL processing on
off(2):SSL processing halted
encryptProcessingStateReason
normal(1): Normal
hardware(2): Change caused by hardware fault
consoleBypass(3): Bypass mode enabled at
console
consoleInline(4): Inline mode enabled at
console
frontPanelBypass(5): Bypass mode enabled at
front panel
frontPanelInline(6): Inline mode enabled at
front panel
serverInterfaceState
State of the server-side interface
networkInterfaceState
State of the network-side interface
utilWindow
Sliding window (in seconds) to calculate average
connections, CPU utilization, and active
connnection rates
cpuUtil
CPU utilization percentage (0-100)
6-12
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 6
SNMP
cpuUtilNetwork
CPU utilization percentage processing network
traffic (0-100)
cpuUtilProxy
CPU proxy utilization percentage (0-100)
cpuUtilHiWater
CPU utilization high water mark (2-100)
cpuUtilLoWater
CPU utilization low water msrk (1-99)
cpuUtilState
When CPU utilization exceeds the hi water mark,
CPU utilization state is in alert and is not
returned to normal until the lo water threshold
is crossed
sslCps
SSL connections per second
sslCpsMaximum
Maximum SSL connection rate in connections per
second since (re)start
sslCpsHiWater
SSL connections per second high water mark
sslCpsLoWater
SSL connections per second low water mark
sslCpsState
When SSL connections per second exceeds the hi
water mark, sslCpsState is in alert and is not
returned to normal until the lo water threshold
is crossed
sslConnCnt
Current number of concurrent open SSL
connections
sslConnCntMaximum
Maximum number of concurrent open SSL
connections since (re)start
6-13
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 6
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
sslConnTotal
Total number of SSL connections processed
sslConnCntHiWater
Concurrent open SSL connection count high water
mark
sslConnCntLoWater
Concurrent open SSL connection count low water
mark
sslConnCntState
When concurrent open SSL connection count
exceeds the hi water mark, sslConnCntState is in
alert and is not returned to normal until the lo
water threshold is crossed
encryptedBps
Encryption rate in bytes per second
encryptedBpsMaximum
Maximum encryption rate in bytes per second
since (re)start
encryptedBytesTotalMb
Total number of megabytes of data encrypted
decryptedBps
Decryption rate in bytes per second
decryptedBpsMaximum
Maximum decryption rate in bytes per second
since (re)start
decryptedBytesTotalMb
Total number of megabytes of data decrypted
sslOverloadInterval
The periodic interval (in seconds) used when
counting the number of spilled or throttled SSL
connections. If any SSLconnections were spilled
or throttled in the lastsslOverloadInterval, a
trap is generated. If sslOverloadInterval is 0,
no trap is generated
throttlesPerSec
Number of throttles per second
6-14
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 6
SNMP
throttlesPerSecMaximum
Maximum number of throttles per second since
(re)start
throttlesTotal
Total number of throttles since (re)start
throttles
Total number of throttles in the last
sslOverloadInterval
spillsPerSec
Number of spills per second
spillsPerSecMaximum
Maximum number of spills per second since
(re)start
spillsTotal
Total number of spills since (re)start
spills
Number of spills in the last sslOverloadInterval
refusedSslInterval
The periodic interval (in seconds) used when
counting the number of refused SSL connections.
If any SSL connections were refused in this time
interval, a trap is generated.
cipherSuiteMismatch
Number of refused SSL connections in the last
refusedSslInterval which are due to inability of
the client and server to agree upon a cipher
suite
clientCertAuthFail
Number of refused SSL connections in the last
refusedSslInterval which are due to
authentication failure of the client
certificate
6-15
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 6
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Trap Summary
The following list summarizes the traps generated by the 7110/7115.
For details about a particular trap, please read the description of each
MIB above, or read the documentation within the MIB file. Traps are
generated by SNMP.
Standard SNMP Traps
coldStart
warmStart
authenticationFailure
linkUp
linkDown
Private Traps in ssl-appliance-mib.my
encryptionStopped
Alert issued whenever the device stops
processing SSL traffic
encryptionResumed
Resumes processing traffic after having been
stopped
serverInterfaceStateChanged
The server-side interface state changed
networkInterfaceStateChanged
The network-side interface state changed
cpuUtilAlert
The device has exceeded the CPU utilization
high water threshold
cpuUtilNormal
CPU utilization back to normal levels
sslCpsAlert
The device has exceeded the SSL connections
per second high water threshold
sslCpsNormal
The SSL connections per second processed by
the device is back to normal levels
6-16
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 6
SNMP
sslConnCntAlert
The device has exceeded the open SSL
connection count high water threshold
sslConnCntNormal
The open SSL connection count of the device
is back to normal levels
sslConnectionRefusedMismatch
SSL connections were refused in the past
sslRefusedInterval due to cipher suite
negotiation
failuresslConnectionRefusedAuthFail
SSL connections were refused in the past
sslRefusedInterval due to authentication
failure of the client certificate
sslOverloadSpills
SSL connections were spilled in the past
sslOverloadInterval
sslOverloadThrottles
SSL connections were throttled in the past
sslOverloadInterval
appRestartAlert
SSL processing application has restarted
Enabling SNMP.
Enabling and disabling SNMP is accomplished with the CLI
command, setsnmp snmp enable|disable. Operational status can be
verified using showsnmp snmp.
Examples:
Intel 7115> setsnmp snmp enable
Intel 7115> showsnmp snmp
SNMP: enable
Intel 7115> setsnmp snmp disable
Intel 7115> showsnmp snmp
SNMP: disable
6-17
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 6
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Specifying SNMP Information
Configurable SNMP parameters can be set collectively using the
setsnmp snmp_info command as illustrated below:
Intel 7115> setsnmp snmp_info
SNMP port [161]: 161
SNMP trap port [162]: 162
Contact Person []: support
System Location []:
System Name []: 7115
Current values of SNMP parameters are displayed using the
shownmp snmp_info command:
Intel 7115> showsnmp snmp_info
SNMP port: 161
SNMP trap port: 162
Contact Person: support
System Name: 7115
System IP Address: x.x.x.x
System Netmask: y.y.y.y
Default Route: z.z.z.z
You can also configure SNMP information elements individually
using the following commands:
•
•
•
•
•
setsnmp snmp_port sets the SNMP port
setsnmp trap_port sets the SNMP trap port
setsnmp sys_contact sets the contact person
setsnmp sys_name sets the system name
setsnmp sys_location sets the system location
Correspondingly, the values set with the above commands are
displayed using the commands:
•
•
•
•
•
showsnmp snmp_port
showsnmp trap_port
showsnmp sys_contact
showsnmp sys_name
showsnmp sys_location.
6-18
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 6
SNMP
Community String
Use CLI commands setsnmp snmp_community, list
snmp_community and delete snmp_community to set, list, and
delete SNMP community strings.
Intel 7115> setsnmp snmp_community
IP []:
Community String []:
Intel 7115> list snmp_community
SNMP Community List
IP: x.x.x.x => String : public =>
Rights : read
Intel 7115> delete snmp_community
SNMP Community String(s) Deletion.
<2> Current Available SNMP Community String(s):
1.) IP:
2.) IP:
0.0.0.0 => String:
public
0.0.0.0 => String: private
Enter number (1 to 2) to delete (q to quit) [1]: 2
Enter number (1 to 2) to delete (q to quit) [1]: q
6-19
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 6
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Trap Community String
Use CLI commands, setsnmp trap_community, list
trap_community and delete trap_community to set, display, and
delete trap community strings.
Intel 7115> setsnmp trap_community
SNMP Trap Community String(s) Setting.
Enter a SNMP Trap Community IP (q to quit): 0.0.0.0
Enter a SNMP Trap Community String (q to quit): private
Enter a SNMP Trap Community IP (q to quit): 0.0.0.0
Enter a SNMP Trap Community String (q to quit): public
Enter a SNMP Trap Community IP (q to quit): q
Intel 7115> list trap_community
SNMP Trap Community String(s) information.
<2> Current SNMP Trap Community String(s):
1.) IP:
2.) IP:
0.0.0.0 => String: public
0.0.0.0 => String: private
Intel 7115> delete trap_community
SNMP Trap Community String(s) Deletion.
<2> Current Available SNMP Trap Community String(s):
1.) IP:
2.) IP:
0.0.0.0 => String:
0.0.0.0 => String:
public
private
Enter number (1 to 2) to delete (q to quit) [1]: 2
Enter number (1 to 2) to delete (q to quit) [1]: q
6-20
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 6
Access Control
Access Control
The 7110/7115 provides block and permit commands which allow
you to deny or allow clients to access servers based on IP, IP mask,
port and port mask.
To block a client, specified by IP and IP mask, from accessing a
specified server, use the create block command as illustrated below:
NOTE: To show, list or
delete blocks andpermits,
see the Command
Intel 7115> create block
Client IP to block [0.0.0.0]: 10.1.2.1
Client IP mask [0.0.0.0]: 255.255.255.255
Server IP to block [0.0.0.0]: 20.1.2.1
Server IP mask [0.0.0.0]: 255.255.255.255
Server Port to block: 80
Reference in Chapter 5.
Server Port mask [0xffff]:<Enter>
To permit a client, specified by IP and IP mask, access to a specified
server, use the create permit command as illustrated below:
Intel 7115> create permit
Client IP [0.0.0.0]: 10.1.2.1
Client IP Mask [0.0.0.0]:255.255.255.255
Server IP [0.0.0.0]:20.1.2.1
Server IP Mask [0.0.0.0]:255.255.255.255
Server port [xx]: 443
Server port mask [0xffff]: <Enter>
6-21
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 6
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Notes
6-22
Download from Www.Somanuals.com. All Manuals Search And Download.
Alarms and
Monitoring
Overview
The Intel® NetStructure™ 7110/7115 e-Commerce Accelerator
supports the configuration of alarms and to be sent to the console
upon pre-designated events, and of periodic status-monitoring
reports. Both alarms and monitor reports are single lines of text, with
alarms being prefaced by the letter “A,” and monitor reports with the
letter “M,”and both have timestamps. Both alarms and monitor
reports can be written to the local administration console or to remote
management sessions (Telnet or Secure Shell only).
Alarms can be configured to immediately notify the user of the
following conditions:
•
•
•
Encryption Status change
Refused SSL connections
Utilization (Threshold) alarms
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 7
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
•
•
Overload alarms
Network Link Status
All alarms are disabled by default and may be enabled in any
combination.
Alarm format:
A:yyyymmddhhmmss:
ALARM_CODE:MODIFIER:EXTENDED_DATA:/
*message*/
Where:
A: Identifies the message as an alarm (as
opposed to a monitor report).
yyyymmddhhmmss: The timestamp.
ALARM_CODE: The alarm type:
[ESC|RSC|UTL|OVL|NLS].
MODIFIER: The alarm modifier, a code
identifying the event that triggered the
alarm.
NOTE: The Encryption
Status Change alarm
(ESC) does not display
extended data.
EXTENDED_DATA: Any additional relevant data.
/*message*/: Human-readable text description
of the alarm.
The CLI commands for alarm configuration are:
Command
set alarms
Parameters
Default
all, esc, rsc, utl, ovl, nls none
show alarms
7-2
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 7
Alarm Types
For example:
Intel 7115> set alarms
Select monitoring fields (all, esc, rsc,
utl, ovl, nls) [all]: all
Intel 7115> show alarms
All alarms are enabled.
Intel 7115> set alarms none
Intel 7115> show alarms
All alarms are disabled.
Alarm Types
The configurable alarm types are detailed in separate sections below.
ESC: Encryption Status Change
Alarm
When enabled, an alarm is issued when the device is changed
between INLINE and BYPASS modes. This change can be made
from CLI using the commands, inline or bypass, or at the device’s
front panel by pressing the BYPASS button.
Format:
A:yyyymmddhhmmss:ESC:HDWR|CONB|CONI|FNTB|
FNTI|APPR:/*message*/
Where:
A: identifies the message as an alarm.
yyyymmddhhmmss: is the timestamp.
ESC: identifies the message as an Encryption
Status Change Alarm.
Alarm Modifiers and Messages:
HDWR: indicates crypto card failure
CONB: indicates console-controlled bypass
CONI: indicates console-controlled inline
7-3
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 7
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
FNTB: indicates front panel-controlled
bypass
FNTI: indicates front panel-controlled
inline
APPR: indicates application restart
RSC: Refused SSL Connections
When enabled, an alarm is generated whenever SSL connections are
refused for cipher suite mismatch or client certificate authentication
failure during the current user-specified period (5 to 65000 seconds,
default: 15 seconds). The total number of refused SSL connections is
reported along with the reason for refusal. This alarm can be enabled
or disabled at the CLI.
Format:
A:yyyymmddhhmmss:RSC:CSMM|CCAF:XXX:
/*message*/
Where:
A: identifies the message as an alarm.
yyyymmddhhmmss: is the timestamp.
RSC: identifies the message as an Refused
SSL Connections Alarm.
Alarm Modifiers and Messages
CSMM: Cipher suite mismatch
CCAF: Client certificate authenticate
failure
Extended Data
XXX: An integer value indicating the number
of refused SSL connections that occurred in
the current alarm period.
RSC Alarm CLI Commands
To set Overload Alarm time window:
set rsc_window <seconds> (Range: 5-65000,
default: 15)
7-4
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 7
Alarm Types
To display Overload Alarm time window
show rsc_window
Examples:
Intel 7115> set rsc_window 10
Intel 7115> show rsc_window
Check refused SSL connections [secs]: 10
UTL: Utilization Threshold Alarm
This alarm monitors three utilization threshold values:
•
•
•
CPU
Connections per Second
Total Open Connections.
When enabled, an alarm is issued whenever any of the utilization
values exceeds its high-water mark, or, having exceeded the high-
water mark, drops below the low-water mark. The user defines the
high and low-water marks. By default, the high-water mark is 90%
and the low-water mark is 60%.
The data collected for utilization threshold metrics tends to be bursty,
so a smoothing algorithm is used to prevent continuous alarms.The
utilization window is a user-specified sliding interval during which
data is collected and averaged. Consequently, shorter intervals are
likely to result in some extraneous alarms. The interval can be set
from 5 to 65000 seconds (default: 15).
Format:
A:yyyymmddhhmmss:UTL:ALRT|NMRL:CPU|CON|CPS:/
*message*/
Where:
A: identifies the message as an alarm.
yyyymmddhhmmss: is the timestamp.
UTL: identifies the message as an
Utilization Threshold Alarm.
Alarm Modifiers and Messages
ALRT: Message: [CPU|Open connections|CPS]
exceed high water mark
7-5
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 7
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
NMRL: Message: [CPU|Open connections|CPS]
drop below low water mark
Extended Data
CPU: Indicates that CPU Utilization
triggered the alarm.
CON: Indicates that Total Active Connections
triggered the alarm.
CPS: Indicates that Connections per Second
triggered the alarm.
UTL Alarm CLI commands
To set Utilization Threshold Alarm time window:
set utl_window <seconds> (Range: 5-65000,
default: 15)
To set Utilization Threshold Alarm high-water value:
set utl_high <percentage> (Range: 2-100,
default: 90)
To set Utilization Threshold Alarm low-water value:
set utl_low <percentage> (Range: 1-99,
default: 60)
To display current settings:
show utl_window
show utl_high
show utl_low
Examples:
Intel 7115> set utl_window 10
Intel 7115> show utl_window
Utilization window set [secs]: 10.
Intel 7115> set utl_highwater 80
Intel 7115> show utl_highwater
Utilization High water mark [%]: 80
Intel 7115> set utl_lowwater 60
Intel 7115> show utl_lowwater
Utilization Low water mark [%]: 60
7-6
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 7
Alarm Types
OVL: Overload Alarm
WARNING: This alarm
indicates loss of encryp-
tion/decryption.
When enabled, an alarm is issued upon occurence of overloads
resulting in spills or throttles during the current user-configured
alarm period (5 to 65000 seconds, default: 15 seconds).
Format:
A:yyyymmddhhmmss:OVL:SPIL|THRT:XXX:
/*message*/
Where:
A: identifies the message as an alarm.
yyyymmddhhmmss: is the timestamp.
OVL: identifies the message as an Overload
Alarm.
Alarm Modifiers and Messages:
SPIL: indicates overload resulting in a
spill. Message: Spill mode.
THRT: indicates overload resulting in a
throttle. Message: Throttle mode.
Extended Data:
XXX: An integer value indicating the total
number of overload events that occurred
during the most recent alarm period.
OVL Alarm CLI Commands:
To set Overload Alarm time window:
Intel 7115> set ovl_window <seconds> (Range:
5-65000, default: 15)
To display Overload Alarm time window:
Intel 7115> show ovl_window
Examples:
Intel 7115> set ovl_window 10
Intel 7115> show ovl_window
Check for overload conditions [sec]: 10
7-7
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 7
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
NLS: Network Link Status Alarm
An alarm is issued whenever the Network or Server link status is
changed.
Format:
A:yyyymmddhhmmss:NLS:NETL|SVRL:LNKD|10HDX|10
FDX|100HDX|100FDX:/*message*/
Where:
A: identifies the message as an alarm.
yyyymmddhhmmss: is the timestamp.
NLS: identifies the message as a Network
Link Status Alarm.
Alarm modifiers and messages:
NETL: indicates the network port status.
Message: [No carrier|10Mb/s|100Mb/s][half
duplex|full duplex]
SVRL indicates the server port status.
Message: [No carrier|10Mb/s|100Mb/s] [half
duplex|full duplex]
Extended Data:
LINKD: indicates no carrier.
10HDX: indicates 10Mb/s, half duplex.
10FDX: indicates 10Mb/s, full duplex.
100HDX: indicates 100Mb/s, half duplex.
100FDX: indicates 100Mb/s, full duplex.
Alarm Logging
The 7110/7115 maintains a circular buffer of alarms issued. The most
recent alarms, as well as historical logs generated and saved as a
result of exceptional conditions, are viewable at the console or in
Telnet or Secure Shell (SSh) remote sessions. Viewing the current
alarms results in an immediate dump of the alarm buffer.
7-8
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 7
Alarm Logging
The historical logs consist of a snapshot of the information retrievable
via the status line command followed by a dump of the alarm buffer
existing at the time of the exceptional condition.
These alarms can be viewed on the console using the CLI command,
status alarms. Additionally, any logs generated and saved as a result
of an exceptional condition are viewable by using the CLI command,
status <log filename>. (A list of the viewable log files is displayed
using the list logs command.)
Below are examples of the CLI commands for log viewing, the
defaults, and ranges where applicable:
Examples, list logs and status commands:
Intel 7115> list logs
20000727_145544
Intel 7115> status 20000727_145544
================= STATE ====================
Boot time:
2000
Thu Jul 27 14:54:21
Curr time:
2000
Thu Jul 27 14:55:43
Restarts:
3
KTR Mask:
0xFFFFF3DD
0
Total Connections:
Active Connections:
Connections/Second:
0, 0 (cur, max)
0, 0 (cur, max)
Util Status:
Secure Bytes Read:
Plain Bytes Read:
Secure Bytes Wrote:
Plain Bytes Wrote:
Bytes Allocated to dbufs:
Bytes Per dbuf:
0
0
0
0
0
0
Spill Mode:
disable
7-9
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 7
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Transactions Spilled:
Times Thottled Accepts:
Bypass Mode:
0
0
disable
L&M board status:
(0x00000060)
RESPEND INLINE
Network NIC:
Duplex
100baseTX Half
(0x00000026
0x00000003 0x00000026)
Server NIC:
No carrier
(0x00000023
0x00000001 0x00000023)
Network LED:
on
Server LED:
off
Next heartbeat deadline:
SSL Caching:
never
Enabled.
--------------- Configuration --------------
conlog 0xffffffef
ilog 0xffffffff
trace 0xfffff3dd
media auto
logport tty01
cache 3
server_tmo 5
client_tmo 30
serverif exp1
netif exp0
map 0.0.0.0 443 80 default
kpanic reboot
monitoring_interval 0
monitoring_fields 0x1f
alarm_mask 0x0000001f
7-10
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 7
Alarm Logging
ovl_window 15
rsc_window 15
utl_window 15
utl_high 90
utl_low 60
idle 300
kstrength 512
con_speed 9600
con_bits 8
con_stop 1
con_parity n
defcert_cname US
defcert_state California
defcert_city San Diego
defcert_orgname Intel Corporation
defcert_orgunit Network Equipment Division
defcert_name www.intel.com
defcert_email [email protected]
prompt Intel 7115>
trap_authen
remote_if exp0
ip 10.1.11.34
netmask 255.255.0.0
A:07/27/2000 14:54:47:NLS:SVRL:NC:/* Server port
status, No carrier */
A:07/27/2000 14:54:41:NLS:SVRL:100FDX:/* Server
port status, 100Mb/s, full dupl/
A:07/27/2000 14:54:21:NLS:NETL:100HDX:/* Network
port status, 100Mb/s, half dup/
A:07/27/2000 14:54:21:NLS:SVRL:NC:/* Server port
status, No carrier */
A:01/01/1970 00:00:00:ESC:APPR:3:/* Application
Restarted */
Intel 7115>
7-11
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 7
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Example, status alarms command:
Intel 7115> status alarms
A:07/27/2000 14:57:05:ESC:CONI:/* Console inline
*/
A:07/27/2000 14:57:05:NLS:NETL:100HDX:/* Network
port status, 100Mb/s, half dup/
A:07/27/2000 14:57:01:ESC:CONB:/* Console bypass
*/
A:07/27/2000 14:57:01:NLS:NETL:NC:/* Network port
status, No carrier */
A:07/27/2000 14:56:51:NLS:SVRL:NC:/* Server port
status, No carrier */
A:07/27/2000 14:56:46:NLS:SVRL:100FDX:/* Server
port status, 100Mb/s, full dupl/
A:07/27/2000 14:56:30:ESC:CONI:/* Console inline
*/
A:07/27/2000 14:56:30:NLS:NETL:100HDX:/* Network
port status, 100Mb/s, half dup/
A:07/27/2000 14:56:29:NLS:NETL:NC:/* Network port
status, No carrier */
A:07/27/2000 14:56:29:NLS:SVRL:NC:/* Server port
status, No carrier */
Intel 7115>
7-12
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 7
Monitoring
Monitoring
Monitoring Reports
A monitoring report is one line of user-configurable text displayed at
the console at a user-configurable interval of between five and 65000
seconds. The interval default is 15 seconds.Console Configuration
Monitoring reports are disabled by default, and are enabled with the
CLI monitor... command set. The monitoring application is aware of
the port on which the enable command arrives, and accordingly sends
reports to that same port, thus monitoring reports are displayed on the
same console from which the feature is enabled.
Report Configuration
You can specify the fields to be displayed in each report. Reports
begin with the letter “M” (for monitor report, to distinguish them
from alarm reports) and the timestamp. The other fields available are
user-selectable via a CLI command see “CLI Commands” this below
in this section). The standard default fields are mode, failmode, CPU,
SSLCS, and OVR. Monitor reports are disabled by default.
Monitor report format:
M:yyyymmddhhmmss:mode:failmode:CPU;i,k,a:SSL
CS;c,m,t:OVR;r,c,m,t:
NetIF;s:SvrIF;s:BES;c,m,t;BDS;c,m,t
Where:
M Monitor report
yyyymmddhhmmss Timestamp
mode Bypass mode status [INLINE|BYPASS]
failmode Fail mode status [SAFE|THRU]
CPU;i,k,a CPU%; (i)dle, (k)ernel,
(a)pplication
SSLCS;c,m,t SSL Connections per Second;
(c)urrent, (m)ax, (t)otal
OVR;r,c,m,t Overload events; (r)esponse
[SPIL|THRT], (c)urrent, (m)ax,
7-13
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 7
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
(t)otal
NetIF;s Net interface; (s)tatus
[NC|10HDX|10FDX|100HDX|100FDX]
SvrIF;s Svr interface; (s)tatus
[NC|10HDX|10FDX|100HDX|100FDX]
BES;c,m,t Bytes Encrypted per Second;
(c)urrent, (m)ax, (t)otal
BDS;c,m,t Bytes Decrypted per Second;
(c)urrent, (m)ax, (t)otal
Monitoring Reports CLI Commands
Below are the CLI commands for console monitoring, with defaults
and ranges where applicable:
set monitoring_interval <seconds> (Range: 5-
65000; Default: 15 )
show monitoring_interval
set monitoring_fields <fields> (Range: all,
mode, failmode, cpu, cps, ovrld, link, enc,
dec; Default: mode, failmode, cpu, cps,
ovrld)
show monitoring_fields
set monitoring enable|disable (Default:
disable)
show monitoring
Examples:
Intel 7115> set monitoring_interval 15
Intel 7115> show monitoring_interval
Monitoring report interval [secs]: 15
Intel 7115> set monitoring disable
Intel 7115> show monitoring
The monitoring report is disabled for this
CLI.
Intel 7115> set monitoring_fields
Select monitoring fields (all, mode,
failmode, cpu, cps, ovrld, link, enc,
dec) [all]: all
7-14
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 7
Monitoring
Intel 7115> show monitoring_fields
All monitoring fields are enabled.
Intel 7115> set monitoring enable
Intel 7115> show monitoring
The monitoring report is enabled for this
CLI.
7-15
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 7
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Notes
7-16
Download from Www.Somanuals.com. All Manuals Search And Download.
s
Software Updates
Use the import upgrade command to update/upgrade your Intel®
NetStructure™ 7110/7115 e-Commerce Accelerator software. When
you upgrade your 7110/7115 software, the configuration (including
all keys, certificates, and mapping) is saved. However, all log files are
cleared. The software is in the form of an image file (*.IMG).
Use the import patch command to install an Intel-provided patch to a
current software release. Patches typically effect fixes to minor
software issues. Intel Support can provide guidance regarding
patches appropriate to your system, if any.
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 8
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Using Windows§
HyperTerminal§
Command: import upgrade
Use the 7110/7115’s aux console port, which defaults to 115.2 kbps,
for greater speed. The import procedure (using xmodem) requires
approximately 7 minutes at 115.2 kbps.
1. Download the image file (.IMG) to the local PC.
2. Connect the serial cable from COM1 or COM2 to the 7110/7115
auxiliary console.
3. Log in to the 7110/7115.
4. Type the import upgrade command. The command prompts for
xmodem or uuencode. Press Enter to use the default (xmodem).
Intel 7115> import upgrade
Import protocol: (xmodem, uudecode)
[xmodem]: <Enter>
Start xmodem upload now
Use Ctl-X to cancel upload
5. In HyperTerminal§, click Send File from the Transfer menu,
select the file (you can type the filename or click the Browse
button to find the file), click to select the transfer protocol (1K
xmodem), and click Send.
Verifying upgrade image...
Upgrade image valid
=== Release x.x
=== Load xx, Fri Aug 25 05:31:51 2000
WARNING: All saved
logs will be deleted and
the system will reboot
upon successful
completion of the
upgrade.
6. Press y (for yes) at the “Continue with upgrade?” prompt.
Continue with upgrade? [n]: y
Upgrading...
System rebooting...done
8-2
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 8
Using Unix§ ‘cu’ and uuencoded image file
Command: import patch
Use the 7110/7115’s aux console port, which defaults to 115.2 kbps,
for greater speed. The import procedure (using xmodem) requires
approximately 7 minutes at 115.2 kbps.
1. Download the patch file (.patch) to the local PC.
2. Connect the serial cable from COM1 or COM2 to the 7110/7115
auxiliary console.
3. Log in to the 7110/7115.
4. Type the import patch command. The command prompts for
xmodem or uuencode. Press Enter to use the default (xmodem).
Intel 7115> import patch
Import protocol: (xmodem, uudecode)
[xmodem]: <Enter>
Start xmodem upload now
Use Ctl-X to cancel upload
5. In HyperTerminal§, click Send File from the Transfer menu,
select the file (you can type the filename or click the Browse
button to find the file), click to select the transfer protocol (1K
xmodem), and click Send.
Verifying patch image...
Patch successfully imported.
The patch becomes effective upon the next system reboot. Should a
patch fail upon import, the last successfully imported patch is
reapplied.
Using Unix§ ‘cu’ and
uuencoded image file
Command: import upgrade
1. Download the image file (assume the name is nn.img) to the local
Unix§ machine.
2. Uuencode the image file.
uuencode nn.img nn.img >nn.uu
3. Connect the serial cable to the 7110/7115 auxiliary console.
8-3
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 8
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
4. Use the ‘cu’ program to connect to the 7110/7115 (Device name
may vary depending on your operating system).
cu –l /dev/cuaa0 –s 115200
5. Log in to the 7110/7115.
6. Type the import upgrade command. At the prompt, press u or
type uudecode.
Intel 7115>import upgrade
Import protocol: (xmodem, uudecode)
[xmodem]: u
Type or paste in data, end with ... alone on
line.
7. To send the uuencoded file use the “~>” command.
~>nn.uu
Verifying upgrade image...
Upgrade image valid
=== Release x.x
=== Load xx, Fri Aug 25 05:31:51 2000
WARNING: All saved
logs will be deleted and
the system will reboot
upon successful
completion of the
upgrade.
8. Press y (for yes) at the “Continue with upgrade?” prompt.
Continue with upgrade? [n]: y
Upgrading...
System rebooting...done
Command: import patch
1. Download the patch file (assume the name is nn.patch) to the
local Unix§ machine.
2. Uuencode the patch file.
uuencode nn.patch nn.patch >nn.uu
3. Connect the serial cable to the 7110/7115 auxiliary console.
4. Use the ‘cu’ program to connect to the 7110/7115 (Device name
may vary depending on your operating system).
cu –l /dev/cuaa0 –s 115200
5. Log in to the 7110/7115.
8-4
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 8
Using Unix§ ‘cu’ and uuencoded image file
6. Type the import patch command. At the prompt, press u or type
uudecode.
Intel 7115>import patch
Import protocol: (xmodem, uudecode)
[xmodem]: u
Type or paste in data, end with ... alone on
line.
7. To send the uuencoded file use the “~>” command.
~>nn.uu
Verifying patch image...
Patch successfully imported.
8-5
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R 8
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Notes
8-6
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
Item
1
Symptom
Probable Cause
Remedy
•
•
Unit is in
Bypass mode.
•
•
If the Inline LED is not illuminated
Server and/or
Network LEDs not
illuminated.
(solid or blinking) take the 7110/
7115 out of Bypass mode by either
pressing the Bypass switch on the
unit’s front panel or using the CLI’s
inline command.
Improper
cabling.
Depending on what type of
equipment the 7110/7115 is
connected to, either straight-
through or crossover Cat-5 network
cables are required for both Network
and Server ports. Switch out the
different cable types at each port
until both Network and Server LEDs
are illuminated.
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R
9
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Item
2
Symptom
Probable Cause
Remedy
Improper cabling.
•
•
Refer to Item 1 in this table.
Non-SSL data does
not pass through
7110/7115.
If both Network and Server LEDs
are illuminated, configure the 7110/
7115 to Fail-through mode (see
Appendix B) and place the unit in
Bypass mode. This effectively
bypasses the 7110/7115, so if the
problem persists its origin is
elsewhere in the network.
The client timeout
value is too small.
3
Web pages are not
completely
Increase the interval with the
following command:
displayed, or an
error message such
as, “Document
Contains No Data”
appears.
“Client timeout” is
the interval that the
connection
between the client
and server can
remain idle (i.e., no
data crosses the
connection in
Intel 7115> set client_tmo
<n>
where <n> is the interval in seconds.
The default is five seconds. The
recommended value is 1.5 times the
longest server response time.
either direction)
following a client
request.
•
Improper
mappings.
•
•
See Mapping in Chapter 3.
4
5
SSL traffic does not
pass through 7110/
7115
See Item 1 in this table.
•
Improper
cabling.
Error message:
The page cannot be
displayed.
The digital
Use the default key and certificate, or
create new key and unsigned
certificate. Try the page again.
certificate and/or
private key is
corrupt.
If the error no longer appears, recreate
your private key and certificate
signing request (CSR) and resubmit to
the certificate authority to get a new
certificate.
9-2
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R
9
Troubleshooting
Probable Cause
Item
6
Symptom
Remedy
Error message
indicates that the
browser does not
recognize the
signer of this
certificate after
loading global
server ID.
The intermediate
certificate is not
installed or is
installed
See Global Site Certificates in
Chapter 3 for correct procedures.
improperly.
9-3
Download from Www.Somanuals.com. All Manuals Search And Download.
C H A P T E R
9
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Item
7
Symptom
Probable Cause
Remedy
Error message:
Server/Network
media mismatch
Server and
network ports
have
Use the status command to determine
the media settings:
autonegotiated to
different media
settings.
Intel 7115> status
.
.
Network port 100baseTX Full
Duplex
Server port 10baseT, Half
Duplex
Then use the nic command to force
common media attributes, e.g.:
Intel 7115> nic
1 - auto
2 - 10baseT, half duplex
3 - 10baseT, full duplex
4 - 100baseTX, half duplex
5 - 100baseTX, full duplex
Select media type [1] 2
In the example above, 2 is the correct
choice because the setting must reflect
the “least common denominator” of
both media speed and duplex attribute,
i.e., the server port is determinative
because it has both the lower speed
and lower (half) duplex attribute.
9-4
Download from Www.Somanuals.com. All Manuals Search And Download.
Front Panel
The following diagram shows the LEDs, buttons, switches and con-
nections for the Intel® NetStructure™ 7110/7115 e-Commerce Ac-
celerator. Note that there is no power switch or button. Power is
applied to the device by connecting the power cable.
LEDs
LEDs
Power
(green)
Error
(red)
Activity
(green)
Overload
(amber)
Reset
Network Link Inline Server Link
(green)
(green)
(green)
Console
(CLI)
Aux Console
(Diagnostics)
Network Link
(RJ45)
Server Link
(RJ45)
Bypass
Fail-through switch
Figure A-1: Front Panel Connectors, Controls, and Indicators
Download from Www.Somanuals.com. All Manuals Search And Download.
A P P E N D I X A Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Buttons and Switches
There are two buttons and one switch on the front panel of the 7110/
7115.
Button/Switch
Reset button
Action
Press momentarily to issue a soft reset to the 7110/7115. Press for
5 seconds to reset the 7110/7115 and restore the factory defaults.
Bypass button
Press to physically force bypass mode (bypass 7110/7115
processing).
Fail-through/
Default: Fail-safe (up position), the network connection is broken
Fail-safe switch
during a 7110/7115 failure.
Fail-through (down position), the network connection is
maintained during a 7110/7115 failure. Refer to Failure/Bypass
Modes in Appendix B for details.
Front Panel LEDs
The LED display provides high-level 7110/7115 information. There
are seven LEDs on the 7110/7115’s front panel, in two groups of four
and three, respectively.
LED
Status
ON – Power is supplied to 7110/7115.
OFF – No Power to 7110/7115.
ON – Error condition found.
OFF – Normal operation.
Power
Error
A-2
Download from Www.Somanuals.com. All Manuals Search And Download.
A P P E N D I X A
Front Panel LEDs
Status
LED
ON – 7110/7115 is saturated with SSL requests. LED ranges from dim
flickering to bright steady, indicating low to high spillover. Refer to the
spill command for ways to offload requests to another 7110/7115.
Overload
OFF – Normal operation.
ON – SSL processing is being performed. Ranges from dim, when
processing loads are low to bright, when greater amounts of processing
are occuring.
Activity
OFF – No SSL processing is being performed.
ON – Operational network connection.
OFF – No operational network connection.
Network Link
Inline
BLINKING GREEN – Fail-safe mode, which is the default. In the event
of a 7110/7115 failure, traffic will not pass through.
(See Appendix B, Failure/
Bypass Modes)
STEADY GREEN – Fail-through mode, which allows traffic to pass
even with 7110/7115 failure.
OFF – 7110/7115 is not operational, or is in Bypass mode.
ON – Operational server connection.
Server Link
OFF – No operational server connection.
A-3
Download from Www.Somanuals.com. All Manuals Search And Download.
A P P E N D I X A Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Connectors
The following table describes the 7110/7115’s connectors.
Designator
Network
Type Purpose
RJ45 100baseTX/10baseT connection to network (clients),
wired as a host port.
Server
RJ45 100baseTX/10baseT connection to server (or servers),
wired as a hub port.
Console
DB9
DB9
RS-232 DTE console port (9600 8, N, 1)
Aux Console
RS-232 DTE console port (115200, 8, N, 1) includes
kernel diagnostics at boot.
Power
Power input
A-4
Download from Www.Somanuals.com. All Manuals Search And Download.
Failure/Bypass Modes
WARNING: Enabling
bypass mode will
instantly and without
warning terminate all
active remote
The Intel® NetStructure™ 7110/7115 e-Commerce Accelerator is
designed with the ability to automatically bypass e-Commerce traffic
in the event of a failure. If necessary, the user can force a bypass with
the Bypass button or from the command line interface using the
bypass command. There is also a security feature (Fail-through
switch). In the default Fail-safeFail-safe position, this switch
prevents traffic from passing through unprocessed in the event of a
failure or if Bypass mode is manually activated.
management sessions.
The following discussion about the Bypass button and Fail-through
switch assumes that normal conditions for 7110/7115 processing are
in effect (i.e., the user has entered the appropriate CLI commands to
enable 7110/7115 processing).
Download from Www.Somanuals.com. All Manuals Search And Download.
A P P E N D I X B Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
LEDs
Inline
Reset
Network Link
Server Link
(green)
Network Link
Fail-Through switch
Server Link
Bypass
Figure B-1: Front Panel Detail: Failure/Bypass Mode Controls and
Indicators
Bypass Button
Forcing a bypass of the 7110/7115 may be necessary when certain
actions must be performed offline (e.g., configuration changes,
entering certificates, or problem isolation).
To force a bypass of 7110/7115 processing, push the Bypass button
ON. The Network Link, Inline, and Server Link LEDs are off in
Bypass mode. ON disables the 7110/7115’s ability to process e-
Commerce traffic. The mode of the Fail-through switch controls
whether traffic continues to flow unprocessed between the client and
the server (discussed below).
Fail-through Switch (Security
Level)
This switch allows the user to control what happens in the event of a
failure. It is located in a recess between the network link and server
link connectors. Use a small screwdriver or paper clip to manipulate
the switch. The two options are to either let traffic flow through the
7110/7115 in the event of a failure (or the Bypass Switch being on)
B-2
Download from Www.Somanuals.com. All Manuals Search And Download.
A P P E N D I X
B
Fail-through Switch (Security Level)
or to be blocked. When the switch is in Fail-through mode (down
position), traffic is allowed to pass through unprocessed in the event
of a failure of the 7110/7115 or if the Bypass toggle is ON.
During normal processing, the Inline (green) LED on the front panel
indicates whether e-Commerce traffic will pass through in the event
of a failure (depending on Fail-through switch state). Steady green or
blinking green both mean that the 7110/7115 is processing traffic;
blinking green indicates traffic will be blocked if the 7110/7115 fails
(Fail-safe mode), and steady green indicates traffic will continue
(unprocessed) in the event of a failure (Fail-through mode). When the
Inline LED is off, no SSL processing is taking place, which means
either no traffic is passing through (Fail-safe), or the traffic that is
passing through is unprocessed (Fail-through).
The following conditions and Inline LED behavior are possible with
the Fail-through switch and Bypass button:
Device Mode Bypass
Button
Fail-through Traffic Status
Switch Mode
Inline LED
Failed
Failed
N/A
N/A
Fail-safe (Up
position)
No traffic (either direction) off
Fail-through
(Down
Passes through unprocessed off
position)
N/A
N/A
ON (Bypass)
ON (Bypass)
Fail-safe (Up
position)
No traffic (either direction) off
Passes through unprocessed off
Fail-through
(Down
position)
Operational
Operational
OFF (Inline)
OFF (Inline)
Fail-safe (Up
position)
Processing
Processing
Blinking green
Fail-through
(Down
Steady green
position)
B-3
Download from Www.Somanuals.com. All Manuals Search And Download.
A P P E N D I X B Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Notes
B-4
Download from Www.Somanuals.com. All Manuals Search And Download.
Supported Ciphers
The Intel® NetStructure™ 7110/7115 e-Commerce Accelerator
supports only RSA key exchange and authentication. Diffie-Hellman
(including Anonymous and Ephemeral) key exchange/authentication
and DSS authentication are not supported.
Use the set cipher command to specify the cipher. The command
prompts you for the cipher strength and SSL version level. Options
for these values are:
Cipher Strength
•
•
•
All - all supported ciphers (including export ciphers)
High - all ciphers with 168-bit encryption (Triple-DES)
Medium - all ciphers with 128-bit and higher encryption
(including High)
•
•
Low - all ciphers with 64-bit and higher encryption (including
Medium and High)
Export only - all export ciphers
Download from Www.Somanuals.com. All Manuals Search And Download.
A P P E N D I X C Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
SSL Version Level
•
•
•
SSLv2 - all SSL version 2.0 ciphers
SSLv3 - all SSL version 3.0 ciphers
SSLv2 and SSLv3 - all SSL version 2.0 and 3.0 ciphers
The default cipher value is all supported ciphers (both SSLv2 and
SSLv3).
The following table provides ciphers supported by the 7110/7115.
Note that the export version of the software supports only the ciphers
marked “E” in the Profile column.
Name
Protocol Key
Exchange
Authentication Encryption
(key size)
Message
Authentication Medium/
Profile (Hi/
Low/
Export)
3DES(168)
DES-
CBC3-
SHA
SSLv3
SSLv3
RSA
RSA
SHA1
SHA1
H
IDEA(128)
IDEA-
RSA
RSA
M
CBC-SHA
RC4-SHA SSLv3
RC4-MD5 SSLv3
RSA
RSA
RSA
RSA
RSA
RSA
RC4(128)
RC4(128)
DES(56)
SHA1
MD5
M
M
L
DES-
CBC-SHA
SSLv3
SSLv2
SHA1
DES-
CBC3-
MD5
RSA
RSA
RSA
RSA
3DES(168) MD5
IDEA(128) MD5
H
IDEA-
CBC-
MD5
SSLv2
M
C-2
Download from Www.Somanuals.com. All Manuals Search And Download.
A P P E N D I X
C
SSL Version Level
Name
Protocol Key
Exchange
Authentication Encryption
Message
Authentication Medium/
Profile (Hi/
(key size)
Low/
Export)
RC2-
CBC-
MD5
SSLv2
RSA
RSA
RC2(128)
MD5
M
RC4-MD5 SSLv2
RSA
RSA
RSA
RSA
RC4(128
RC4(64)
MD5
MD5
M
L
RC4-64-
MD5
SSLv2
SSLv2
DES-
CBC-
MD5
RSA
RSA
DES(56)
DES(40)
RC2(40)
MD5
SHA1
MD5
L
E
E
EXP-
DES-
CBC-SHA
SSLv3
SSLv3
RSA(512) RSA
RSA(512) RSA
EXP-
RC2-
CBC-
MD5
EXP-
RC4-MD5
SSLv3
SSLv2
RSA(512) RSA
RSA(512) RSA
RC4(40)
RC2(40)
MD5
MD5
E
E
EXP-
RC2-
CBC-
MD5
EXP-
SSLv2
RSA(512) RSA
RC4(40)
MD5
E
RC4-MD5
C-3
Download from Www.Somanuals.com. All Manuals Search And Download.
A P P E N D I X C Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Notes
C-4
Download from Www.Somanuals.com. All Manuals Search And Download.
A P P E N D I X D Intel ® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
VCCI Statement
Class A ITE
This is a Class A product based on the standard of the Voluntary
Control Council for Interference by Information Technology
Equipment (VCCI). If this equipment is used in a domestic
environment, radio disturbance may arise. When such trouble occurs,
the user may be required to take corrective actions.
Internal access to Intel® Express switches is intended only for
qualified service personnel.
FCC Part 15 Compliance
Statement
This product has been tested and found to comply with the limits for
a Class A digital device pursuant to Part 15 of the FCC rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial
environment.
This product generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined
by turning this equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
•
•
Change the direction of the radio or TV antenna.
To the extent possible, relocate the radio, TV, or other receiver
away from the product.
•
Plug the product into a different electrical outlet so that the
product and the receiver are on different branch circuits.
D-2
Download from Www.Somanuals.com. All Manuals Search And Download.
A P P E N D I X D
Canada Compliance Statement (Industry Canada)
If these suggestions don’t help, consult your dealer or an experienced
radio/TV repair technician for more suggestions.
NOTE: This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may
cause undesired operation.
CAUTION: If you make any modification to the equipment not
expressly approved by Intel, you could void your authority to operate
the equipment.
Canada Compliance
Statement (Industry Canada)
Cet appareil numérique respecte les limites bruits radioélectriques
applicables aux appareils numériques de Classe A prescrites dans la
norme sur le matériel brouilleur: "Appareils Numériques", NMB-003
édictée par le Ministre Canadien des Communications.
This digital apparatus does not exceed the Class A limits for radio
noise emissions from digital apparatus set out in the
interference-causing equipment standard entitled: "Digital
Apparatus," ICES-003 of the Canadian Department of
Communications.
CE Compliance Statement
This Intel® NetStructure™ 7110 e-Commerce Accelerator complies
with the EU Directive, 89/336/EEC, using the EMC standards
EN55022 (Class A) and EN55024:1998. This product also complies
with the EU Directive, 73/23/EEC, using the safety standard
EN60950.
D-3
Download from Www.Somanuals.com. All Manuals Search And Download.
A P P E N D I X D Intel ® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
CISPR 22 Statement
WARNING: This is a Class A product. In a domestic environment
this product may cause radio interference in which case the user may
be required to take adequate measures.
VCCI Class A (Japan)
Australia
WARNING
The system is designed to operate in a typical office environment.
Choose a site that is:
•
•
•
Clean and free of airborne particles (other than normal room
dust).
Well-ventilated and away from sources of heat including direct
sunlight.
Away from sources of vibration or physical shock.
D-4
Download from Www.Somanuals.com. All Manuals Search And Download.
A P P E N D I X D
CISPR 22 Statement
•
•
Isolated from strong electromagnetic fields produced by
electrical devices.
In regions that are susceptible to electrical storms, we
recommend you plug your system into a surge suppressor and
disconnect telecommunication lines to your modem during an
electrical storm.
•
Provided with a properly grounded wall outlet.
Do not attempt to modify or use the supplied AC power cord if it is
not the exact type required.
Ensure that the system is disconnected from its power source and
from all telecommunications links, networks, or modem lines
whenever the chassis cover is to be removed. Do not operate the
system with the cover removed.
AVERTISSEMENT
Le système a été conçu pour fonctionner dans un cadre de travail
normal. L’emplacement choisi doit être:
•
Propre et dépourvu de poussière en suspension (sauf la poussière
normale).
•
Bien aéré et loin des sources de chaleur, y compris du soleil
direct.
•
•
A l’abri des chocs et des sources de ibrations.
Isolé de forts champs magnétiques géenérés par des appareils
électriques.
•
Dans les régions sujettes aux orages magnétiques il est
recomandé de brancher votre système à un supresseur de
surtension, et de débrancher toutes les lignes de
télécommunications de votre modem durant un orage.
•
Muni d’une prise murale correctement mise à la terre.
Ne pas utiliser ni modifier le câble d’alimentation C. A. fourni, s’il ne
correspond pas exactement au type requis.
Assurez vous que le système soit débranché de son alimentation ainsi
que de toutes les liaisons de télécomunication, des réseaux, et des
lignes de modem avant d’enlever le capot. Ne pas utiliser le système
quand le capot est enlevé.
D-5
Download from Www.Somanuals.com. All Manuals Search And Download.
A P P E N D I X D Intel ® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
WARNUNG
Das System wurde für den Betrieb in einer normalen Büroumgebung
entwickelt. Der entwickelt. Der Standort sollte:
•
•
sauber und staubfrei sein (Hausstaub ausgenommen);
gut gelüftet und keinen Heizquellen ausgesetzt sein
(einschließlich direkter Sonneneinstrahlung);
•
•
keinen Erschütterungen ausgesetzt sein;
keine starken, von elektrischen Geräten erzeugten
elektromagnetischen Felder aufweisen;
•
in Regionen, in denen elektrische Stürme auftreten, mit einem
Überspannungsschutzgerät verbunden sein; während eines
elektrischen Sturms sollte keine Verbindung der
Telekommunikationsleitungen mit dem Modem bestehen;
•
mit einer geerdeten Wechselstromsteckdose ausgerüstet sein.
Versuchen Sie nicht, das mitgelieferte Netzkabel zu ändern oder zu
verwenden, wenn es sich nicht um genau den erforderlichen Typ
handelt.
Das System darf weder an eine Stromquelle angeschlossen sein noch
eine Verbindung mit einer Telekommunikationseinrichtung, einem
Netzwerk oder einer Modem-Leitung haben, wenn die
Gehäuseabdeckung entfernt wird. Nehmen Sie das System nicht ohne
die Abdeckung in Betrieb.
AVVERTENZA
Il sistema è progettato per funzionare in un ambiente di lavoro tipico.
Scegliere una postazione che sia:
•
Pulita e libera da particelle in sospensione (a parte la normale
polvere presente nell’ambiente).
•
Ben ventilata e lontana da fonti di calore, compresa la luce solare
diretta.
•
•
Al riparo da urti e lontana da fonti divibrazione.
Isolata dai forti campi magnetici prodotti da dispositivi elettrici.
D-6
Download from Www.Somanuals.com. All Manuals Search And Download.
A P P E N D I X D
CISPR 22 Statement
•
In aree soggette a temporali, è consigliabile collegare il sistema
ad un limitatore di corrente. In caso di temporali, scollegare le
linee di comunicazione dal modem.
•
Dotata di una presa a muro correttamente installata.
Non modificare o utilizzare il cavo di alimentazione in c. a. fornito
dal produttore, se non corrisponde esattamente al tipo richiesto.
Prima di rimuovere il coperchio del telaio, assicurarsi che il sistema
sia scollegato dall’alimentazione, da tutti i collegamenti di
comunicazione, reti o linee di modem. Non avviare il sistema senza
aver prima messo a posto il coperchio.
ADVERTENCIAS
El sistema está diseñado para funcionar en un entorno de trabajo
normal. Escoja un lugar:
•
Limpio y libre de partículas en suspensión (salvo el polvo
normal)
•
Bien ventilado y alejado de fuentes de calor, incluida la luz solar
directa.
•
•
Alejado de fuentes de vibración.
Aislado de campos electromagnéticos fuertes producidos por
dispositivos eléctricos.
•
En regiones con frecuentes tormentas eléctricas, se recomienda
conectar su sistema a un eliminador de sobrevoltage y
desconectar el módem de las líneas de telecomunicación durante
las tormentas.
•
Previsto de una toma de tierra correctamente instalada.
No intente modificar ni usar el cable de alimentación de corriente
alterna, si no se corresponde exactamente con el tipo requerido.
Asegúrese de que cada vez que se quite la cubierta del chasis, el
sistema haya sido desconectado de la red de alimentación y de todos
lo enlaces de telecomunicaciones, de red y de líneas de módem. No
ponga en funcionamiento el sistema mientras la cubierta esté quitada
D-7
Download from Www.Somanuals.com. All Manuals Search And Download.
A P P E N D I X D Intel ® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Wichtige Sicherheitshinweise
1. Bitte lesen Sie sich diese Hinweise sorgfältig durch.
2. Heben Sie diese Anleitung für den spätern Gebrauch auf.
3. Vor jedem Reinigen ist das Gerät vom Stromnetz zu trennen.
Vervenden Sie keine Flüssig- oder Aerosolreiniger. Am besten
dient ein angefeuchtetes Tuch zur Reinigung.
4. Um eine Beschädigung des Gerätes zu vermeiden sollten Sie nur
Zubehörteile verwenden, die vom Hersteller zugelassen sind.
5. Das Gerät is vor Feuchtigkeit zu schützen.
6. Bei der Aufstellung des Gerätes ist auf sichern Stand zu achten.
Ein Kippen oder Fallen könnte Verletzungen hervorrufen.
Verwenden Sie nur sichere Standorte und beachten Sie die
Aufstellhinweise des Herstellers.
7. Die Belüftungsöffnungen dienen zur Luftzirkulation die das
Gerät vor Überhitzung schützt. Sorgen Sie dafür, daß diese
Öffnungen nicht abgedeckt werden.
8. Beachten Sie beim Anschluß an das Stromnetz die
Anschlußwerte.
9. Die Netzanschlußsteckdose muß aus Gründen der elektrischen
Sicherheit einen Schutzleiterkontakt haben.
10.Verlegen Sie die Netzanschlußleitung so, daß niemand darüber
fallen kann. Es sollete auch nichts auf der Leitung abgestellt
werden.
11. Alle Hinweise und Warnungen die sich am Geräten befinden sind
zu beachten.
12.Wird das Gerät über einen längeren Zeitraum nicht benutzt,
sollten Sie es vom Stromnetz trennen. Somit wird im Falle einer
Überspannung eine Beschädigung vermieden.
13.Durch die Lüftungsöffnungen dürfen niemals Gegenstände oder
Flüssigkeiten in das Gerät gelangen. Dies könnte einen Brand
bzw. Elektrischen Schlag auslösen.
14.Öffnen Sie niemals das Gerät. Das Gerät darf aus Gründen der
elektrischen Sicherheit nur von authorisiertem Servicepersonal
geöffnet werden.
D-8
Download from Www.Somanuals.com. All Manuals Search And Download.
A P P E N D I X D
Wichtige Sicherheitshinweise
15.Wenn folgende Situationen auftreten ist das Gerät vom
Stromnetz zu trennen und von einerqualifizierten Servicestelle zu
überprüfen:
a. Netzkabel oder Netzstecker sint beschädigt.
b. Flüssigkeit ist in das Gerät eingedrungen.
c. Das Gerät war Feuchtigkeit ausgesetzt.
d. Wenn das Gerät nicht der Bedienungsanleitung ensprechend
funktioniert oder Sie mit Hilfe dieser Anleitung keine
Verbesserung erzielen.
e. Das Gerät ist gefallen und/oder das Gehäuse ist beschädigt.
f. Wenn das Gerät deutliche Anzeichen eines Defektes aufweist.
16.Bei Reparaturen dürfen nur Orginalersatzteile bzw. den
Orginalteilen entsprechende Teile verwendet werden. Der
Einsatz von ungeeigneten Ersatzteilen kann eine weitere
Beschädigung hervorrufen.
17.Wenden Sie sich mit allen Fragen die Service und Repartur
betreffen an Ihren Servicepartner. Somit stellen Sie die
Betriebssicherheit des Gerätes sicher.
18.Zum Netzanscluß dieses Gerätes ist eine geprüfte Leitung zu
verwenden, Für einen Nennstrom bis 6A und einem
Gerätegewicht größer 3kg ist eine Leitung nicht leichter als
H05VV-F, 3G, 0.75mm2 einzusetzen.
D-9
Download from Www.Somanuals.com. All Manuals Search And Download.
A P P E N D I X D Intel ® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Notes
D-10
Download from Www.Somanuals.com. All Manuals Search And Download.
Terms and Conditions
and Software License
Intel Corporation
END USER TERMS AND CONDITIONS OF SALE AND SOFTWARE
LICENSE
IF THE PRODUCT IS PURCHASED DIRECTLY FROM INTEL AND
UNLESS SUCH PARTIES HAVE ENTERED INTO A BILATERALLY
EXECUTED AGREEMENT, WHICH EXPRESSLY TAKES PRECE-
DENCE, THE TERMS AND CONDITIONS STATED HEREIN WILL
APPLY.
IF THE PRODUCT WAS PURCHASED FROM AN INTEL CHANNEL
PARTNER, THEN ONLY SECTIONS 13-23 APPLY TO THE END USER.
1. Entire Agreement: These terms and conditions (“Agreement”) for the sale of
hardware and license of software, which includes the associated docu-
mentation shipped with the hardware and software (“Product”), consti-
tute the complete and exclusive statement of all the terms of the
Agreement between Intel Corporation, (“Intel”) and the purchaser using
the Product for its ordinary internal operation of its business and not for
resale (“End User”) and supersedes all prior understandings, writings,
proposals, representations or communications, oral or written, relating to
the subject matter hereof and unless subsequent different, contradictory
or additional terms and conditions are agreed to in a writing signed by
authorized representatives of both parties. In no event shall this Agree-
ment be deemed an acceptance by Intel of any terms and conditions
included with End User’s purchase order or similar End User document.
Download from Www.Somanuals.com. All Manuals Search And Download.
A P P E N D I X E Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Intel’s performance hereunder is expressly conditioned on End User’s
assent to this Agreement.
2. Orders: End User may purchase Product by submitting a valid purchase order
(“Order”) to Intel at the corporate address stated herein. Orders are sub-
ject to Intel’s written acceptance (“Order Acceptance”). Order Accep-
tance is based in part to approval of credit by Intel to End User as set
forth in the “Credit Terms” Section of this Agreement.
3. Term and Termination Date: This Agreement shall be effective on the date of
the Order Acceptance and continue in effect until terminated by either
party upon thirty (30) days advance written notice unless terminated ear-
lier for breach.
4. Price: The price to be paid by End User shall be that stated on the Order as
accepted on the Order Acceptance. All prices are in U.S. dollars.
5. Credit Terms: Credit terms are made at Intel’s sole discretion by analysis of
End User’s current and historical financial and credit information, bank
and trade references, payment practices, etc. End User agrees to pro-
vide such information to Intel upon request. Intel reserves the right to
refuse payment terms if, in Intel’s sole discretion, such terms would cre-
ate an unreasonable credit risk. In that event, deliveries will be available
only on a C.O.D., cash-in-advance, or irrevocable letter of credit basis.
6. Delivery: Subject to the Section below entitled “Leasing/Renting,” if applica-
ble, Products shall be shipped Ex Works (1990 Incoterms), Intel’s ship-
ping dock. End User is responsible for payment of all costs relating to
transportation, delivery, and insurance, which shall be pre-paid by Intel
and added to the invoice, unless otherwise agreed to on the Order
Acceptance. Title and risk of loss shall pass to End User upon delivery
to the first common carrier except that shipments to destinations outside
of the United States are subject to the “Security Interest and Reservation
of Title” Section of this Agreement.
7. Security Interest And Reservation Of Title: End User hereby grants to Intel
a purchase money security interest covering each shipment of Products
made hereunder (and any proceeds thereof) in the amount of Intel's
invoice for such shipment until Intel receives payment in full. (A pur-
chase money security interest only applies to Products purchased by
End User and the proceeds from the sale of such Products by End User.)
End User agrees to sign and execute any and all documents as required
by Intel to perfect such security interest. For Products shipped to desti-
nations outside of the United States, Intel reserves title in such Products
until End User pays Intel in full for such Products, at which time title in
such Products shall pass to End User (except that in the case of soft-
ware, only title to the media shall pass).
8. Cancellation: Orders cancelled within five (5) days of scheduled shipment
may be subject to a ten percent (10%) cancellation charge.
9. Payment Terms: Payment in full is due thirty (30) days after date of the
invoice. Intel may charge End User interest on any delinquent balance
E-2
Download from Www.Somanuals.com. All Manuals Search And Download.
A P P E N D I X E
at the lesser of eighteen percent (18%) per year or the maximum amount
permitted by law. Intel may refuse shipment to End User if End User is
delinquent in making payments to Intel.
10. Taxes and Duties: End User is responsible for all taxes imposed in connec-
tion with sale to End User of Products or services which Intel may incur
under this Agreement (except taxes imposed on Intel’s income) including
but not limited to all import duties, customs fees, levies or imposts, and
all sales, use, value added, gross receipts or other taxes of any nature
and any penalties, interest and collection or withholding costs associated
with any of the foregoing items. All such amounts are in addition to other
amounts payable hereunder and this obligation shall survive termination
or expiration of this Agreement. If applicable law requires End User to
withhold any income taxes levied by the authorities of Canada on pay-
ments to be made pursuant to this Agreement (“Withholding Tax”), End
User shall take advantage of the reduced Withholding Tax provided for
by the Canada-United States tax treaty then in force and shall be entitled
to deduct such Withholding Tax from the payments due to Intel hereun-
der. End User is further responsible for obtaining import licenses and
preparing and submitting all required documentation in connection with
importing Products including obtaining and providing to Intel Interna-
tional Import Certificates and other supporting documentation required
by Intel in order to apply for United States export licenses.
11. Leasing/Renting: Subject to the provisions of this Section, End User may
request to have Products delivered to it under a leasing/renting arrange-
ment between End User and a lessor/owner (“Lessor”). Intel’s obliga-
tions to accept any Order from Lessor and to deliver Product pursuant to
such Order from Lessor are limited to the following circumstances:
11. 1. The Lessor is Intel who will retain title to the Product and accept
lease or rent payments; or
11. 2. Any Lessor, other than Intel Order, provided that:
11. 2. 1. The Order indicates on its face that Lessor is ordering
the Product identified in the Order on behalf of End
User;
ii. The Order indicates on its face that it is in accor-
dance with, and subject to,
iii. The terms and conditions of this Agreement;
and
iv. Intel’s credit department has approved the Les-
sor.
With respect to any Order issued by any Lessor, other than Intel, sub-
ject to any specific provisions found in a bilaterally-executed agreement
between Intel and Lessor, Lessor will be considered End User’s agent
for the purpose of ordering Product and making payment and the rights
and obligations of End User and Intel identified in this Agreement shall
remain except for the following:
(1). Title to Product delivered pursuant to such Order shall be
presumed vested in Lessor;
E-3
Download from Www.Somanuals.com. All Manuals Search And Download.
A P P E N D I X E Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
(2). The license accompanying the Product shall apply to Les-
sor; and
(3). Notwithstanding anything to the contrary in the license
accompanying the Product, Lessor may transfer such title
and license rights to End User under a leasing arrange-
ment.
12. Returns: No Product may be returned except under warranty for repair or due
to shipment error by Intel.
13. Software License: Intel grants End User a non-exclusive, non-transferable
(except as set forth in this Section) non-exclusive, restricted right to use
the Intel® software as incorporated in or supplied with the Intel hardware
and solely in connection with the operation of the Product for End User’s
own internal business purposes. End User understands that Intel may
update the Intel Product from time to time and such changes shall be
subject to this license grant. End User may transfer the license to use
the Intel software only in connection with a sale or transfer of the Product
and as included with the Product and not on a standalone basis, pro-
vided the transferee agrees to be bound by the terms and condition of
this Agreement. Intel and its suppliers retain all title to, and, except as
expressly licensed herein, all rights to the software, all copies thereof,
and all related documentation and materials. End User may not use,
copy, modify, create derivative works of, distribute, sell, assign, pledge,
sublicense, lease, loan, rent, timeshare, deliver or otherwise transfer the
Intel software, nor permit any other party to do any of the foregoing.
14. No Modifications To Product: Product is shipped in its complete form and
structure; no modifications are needed. End User shall not, nor permit
any other party to modify, reverse engineer, reverse compile, or disas-
semble any part of Product, including any attempt to translate the Intel
software, derive or attempt to derive the software source code or any
part thereof. Any modification or attempt described herein will void the
warranties of this Agreement.
15. Limited Software Warranty: Intel warrants to the first End User purchaser
that the media containing the software is free from defects for a period of
ninety (90) days from date of shipment. End User assumes responsibil-
ity for the selection of the appropriate network or computing equipment,
software, and associated materials. Intel makes no warranty or repre-
sentation that the software will work in combination with any third-party
network or computing equipment or software, that the operation of the
software will be uninterrupted or error free, or that all defects in the soft-
ware will be corrected. No updates are provided under this Agreement.
No warranties for third party software are provided by this warranty.
16. Limited Hardware Warranty: Intel warrants to the original owner that the
product delivered in this package will be free from material defects in
material and workmanship for one (1) year following the latter of: (i) the
date of purchase only if you register by returning the registration card as
indicted thereon with proof of purchase; or (ii) the date of manufacture; or
(iii) the registration date if by electronic means provided such registration
occurs within 30 days from purchase. This warranty does not cover the
product if it is damaged in the process of being installed.
THE ABOVE WARRANTY IS IN LIEU OF ANY OTHER WARRANTY,
WHETHER EXPRESS, IMPLIED OR STATUTORY, INCLUDING, BUT
NOT LIMITED TO, ANY WARRANTY OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE, OR NONINFRINGEMENT,
OR ANY WARRANTY ARISING OUT OF ANY PROPOSAL,
SPECIFICATION OR SAMPLE.
E-4
Download from Www.Somanuals.com. All Manuals Search And Download.
A P P E N D I X E
This warranty does not cover replacement of products damaged by abuse,
accident, misuse, neglect, alteration, repair, disaster, improper installation
or improper testing. If the product is found to be otherwise defective, Intel,
at its option, will replace or repair the product at no charge except as set
forth below, provided that you deliver the product along with a return
material authorization (RMA) number (see below) either to the company
from whom you purchased it or to Intel. If you ship the product, you must
assume the risk of damage or loss in transit. You must use the original
container (or the equivalent) and pay the shipping charge. Intel may
replace or repair the product with either a new or reconditioned product,
and the returned product becomes Intel’s property. Intel warrants the
repaired or replaced product to be free from defects in material and
workmanship for a period of the greater of: (i) ninety (90) days from the
return shipping date; or (ii) the period of time remaining on the original one
(1) year warranty.
This warranty gives you specific legal rights and you may have other
rights which vary from state to state. All parts or components contained in
this product are covered by Intel’s limited warranty for this product; the
product may contain fully tested, recycled parts, warranted as if new. For
warranty information call one of the numbers below.
Returning a Defective Product (RMA): Before returning any product,
contact an Intel Customer Support Group and obtain an RMA number by
calling the non-toll free numbers below:
North America only: (800) 838-7136 or (916) 377-7000
Other locations: Return the product to the place of purchase.
If the Customer Support Group verifies that the product is defective, they
will have the Return Material Authorization Department issue you an
RMA number to place on the outer package of the product. Intel cannot
accept any product without an RMA number on the package.
Limitation of Liability and Remedies: INTEL SHALL HAVE NO LIAB-
LILITY FOR ANY INDIRECT OR SPECULATIVE DAMAGES (INCLUD-
ING, WITHOUT LIMITING THE FOREGOING, CONSEQUENTIAL,
INCIDENTAL AND SPECIAL DAMAGES) ARISING FROM THE USE OF
OR INABILITY TO USE THE PRODUCT, WHETHER ARISING OUT OF
CONTRACT, NEGLIGENCE, TORT, OR UNDER ANY WARRANTY,
IRRESPECTIVE OF WHETHER INTEL HAS ADVANCED NOTICE OF
THE POSSIBILITY OF ANY SUCH DAMAGES, INCLUDING, BUT NOT
LIMITED TO LOSS OF USE, INFRINGEMENT OF INTELLECTUAL
PROPERTY, BUSINESS INTERRUPTIONS, AND LOSS OF PROFITS,
NOTWITHSTANDING THE FOREGOING, INTEL’S TOTAL LIABILITY
FOR ALL CLAIMS UNDER THIS AGREEMENT SHALL NOT EXCEED
THE PRICE PAID FOR THE PRODUCT. THESE LIMITATIONS ON
POTENTIAL LIABILITES WERE AN ESSENTIAL ELEMENT IN SET-
TING THE PRODUCT PRICE. INTEL NEITHER ASSUMES NOR
AUTHORIZES ANYONE TO ASSUME FOR IT ANY OTHER LIABILI-
TIES.
Some states do not allow the exclusion or limitation of incidental or con-
sequential damages, so the above limitations or exclusions may not
apply to you.
Europe only
Intel warrants to the original owner that the product delivered in this pack-
age will be free from defects in material and workmanship for one (1)
year following the later of: (i) the date of purchase only if you register by
returning the registration card as indicated thereon with proof of pur-
chase; or (ii) the date of manufacture; or (iii) the registration date if by
electronic means provided such registration occurs within 30 days from
purchase. This warranty does not cover the product if it is damaged in
E-5
Download from Www.Somanuals.com. All Manuals Search And Download.
A P P E N D I X E Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
the process of being installed.
THE ABOVE WARRANTY IS IN LIEU OF ANY OTHER WARRANTY,
WHETHER EXPRESS, IMPLIED OR STATUTORY, INCLUDING, BUT
NOT LIMITED TO, ANY WARRANTY OF SATISFACTORY QUALITY,
FITNESS FOR A PARTICULAR PURPOSE, OR NONINFRINGEMENT,
OR ANY WARRANTY ARISING OUT OF ANY PROPOSAL, SPECIFI-
CATION OR SAMPLE.
This warranty does not cover replacement of products damaged by
abuse, accident, misuse, neglect, alteration, repair, disaster, improper
installation or improper testing. If the product is found to be otherwise
defective, Intel, at its option, will replace or repair the product at no
charge except as set forth below, provided that you deliver the product
along with a return material authorization (RMA) number (see below)
either to the company from whom you purchased it or to Intel. If you ship
the product, you must assume the risk of damage or loss in transit. You
must use the original container (or the equivalent) and pay the shipping
charge. Intel may replace or repair the product with either a new or
reconditioned product, and the returned product becomes Intel’s prop-
erty. Intel warrants the repaired or replaced product to be free from
defects in material and workmanship for a period of the greater of: (i)
ninety (90) days from the return shipping date; or (ii) the period of time
remaining on the original one (1) year warranty.
All parts or components contained in this product are covered by Intel’s
limited warranty for this product; the product may contain fully tested,
recycled parts, warranted as if new. For warranty information call one of
the numbers below.
English
French
German
Italian
+44 1793 404900
+44 1793 404988
+44 1793 404777
+44 1793 404141
Returning a Defective Product (RMA): Return the product to the place
of purchase for a refund or replacement.
Limitation of Liablility and Remedies: INTEL SHALL HAVE NO LIA-
BILITY FOR ANY INDIRECT OR SPECULATIVE DAMAGES (INCLUD-
ING, WITHOUT LIMITING THE FOREGOING, CONSEQUENTIAL,
INCIDENTAL AND SPECIAL DAMAGES) ARISING FROM THE USE OF
OR INABILITY TO USE THIS PRODUCT, WHETHER ARISING OUT OF
CONTRACT, NEGLIGENCE, TORT, OR UNDER ANY WARRANTY,
IRRESPECTIVE OF WHETHER INTEL HAS ADVANCE NOTICE OF
THE POSSIBILITY OF ANY SUCH DAMAGES, INCLUDING BUT NOT
LIMITED TO LOSS OF USE, BUSINESS INTERRUPTIONS, AND LOSS
OF PROFITS, NOTWITHSTANDING THE FOREGOING, INTEL’S
TOTAL LIABILITY FOR ALL CLAIMS UNDER THIS AGREEMENT
SHALL NOT EXCEED THE PRICE PAID FOR THE PRODUCT. THESE
LIMITATIONS ON POTENTIAL LIABILITIES WERE AN ESSENTIAL
ELEMENT IN SETTING THE PRODUCT PRICE. INTEL NEITHER
ASSUMES NOR AUTHORIZES ANYONE TO ASSUME FOR IT ANY
OTHER LIABILITIES.
This limited Hardware Warranty shall be governed by and construed in
accordance with the Laws of England and Wales. The courts of England
shall have exclusive jurisdiction regarding any claim brought under this
warranty.
E-6
Download from Www.Somanuals.com. All Manuals Search And Download.
A P P E N D I X E
17. Export Law Regulations:
17. 1. Applicable Laws. End User acknowledges that all Products,
spares, documentation or other materials (collectively “Product”)
are subject to applicable import and export regulations of the
United States and of the countries in which End User transacts
business, specifically including U.S. Export Administration Act
and Export Administration Regulations. This Agreement is also
specifically subject to U.S. Department of Commerce regulations
relating to restrictive trade practices or boycotts and the Foreign
Corrupt Practices Act. In no event shall Intel be bound by any
terms and conditions which contravene applicable laws. End
User shall comply with all laws and regulations applicable to the
Product. Without limiting the generality of the foregoing, End
User agrees that it shall not export, re-export, transfer or divert
any of the Product or the direct product thereof to any restricted
place or party in accordance with U.S. export regulations.
17. 2. License Exceptions. End User acknowledges that certain of the
Product are exported under U.S. Export Administration Regula-
tion license exceptions which prohibit transfer, export or re-
export to military end-users or for military uses or for use with
regard to nuclear, chemical or biological weapons activity includ-
ing projects, design, production or stockpiling such weapons.
End User is responsible for compliance with all such license
exceptions.
17. 3. Responsibility for Export Licensing. Intel agrees to use commer-
cially reasonable steps to obtain, at Intel’s expense, all docu-
mentation required by the United States Office of Export
Administration and/or other authorities to permit the exportation
of Product to End User. End User shall take all actions and pro-
vide all information reasonably requested by Intel in order for
Intel to obtain such export licenses. Intel shall have no liability or
obligation to End User if the responsible government authorities
decline to issue any such export licenses. ALL ORDERS
ISSUED PURSUANT TO THIS AGREEMENT ARE SUBJECT
TO THE OBTAINING SAID LICENSES.
17. 4. Import Certificates. End User is responsible for obtaining and
providing to Intel International Import Certificates and other sup-
porting documentation required by Intel in order to apply for
United States export licenses.
17. 5. Encrypted Products. Products containing encryption may require
additional restrictions. Sale of these specific items may require
End User’s written consent to comply with any such additional
restrictions prior to shipment of the Products.
17. 6. Letter of Compliance. Intel may require End User to execute a
Letter of Compliance, as it deems reasonable to meet the
requirements of applicable export regulations.
18. United States Government Legend: The software and documentation is
commercial in nature and developed solely at private expense. The soft-
ware is delivered as “Commercial Computer Software” as defined in
DFARS 252.227-7014 (June 1995) or as a commercial item as defined in
FAR 2.101(a) and as such is provided with only such rights as are pro-
vided in this Agreement. Technical data is provided with limited rights
only as provided in DFAR 252.227-7015 (Nov. 1995) or FAR 52.227-14
(June 1987), whichever is applicable.
E-7
Download from Www.Somanuals.com. All Manuals Search And Download.
A P P E N D I X E Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
19. Copyrights; Trade Secrets: End User acknowledges and agrees that the
structure, sequence and organization of the software (including but not
limited to any images, photographs, animations, video, audio, music,
and text) are the valuable trade secrets of Intel and its suppliers. End
User agrees to hold such trade secrets in confidence. End User further
acknowledges and agrees that ownership of, and Intel and its suppliers
hold title to, the Product, its copyrights and patents and all subsequent
copies thereof regardless of the form or media. End User may not
remove from the Product, or alter, any of the trademarks, trade names,
logos, patent or copyright notices or making, or add any other notices or
marking to the Product.
20. Governing Law: The rights and obligations of the parties hereunder shall be
construed in accordance with, and all disputes hereunder shall be gov-
erned by, the laws of the State of California excluding conflict of law rules
and excluding the United Nations Convention on Contracts for the Inter-
national Sale of Goods. The Superior Court of San Diego County, Cali-
fornia and/or the United States District Court for the Southern District of
California shall have jurisdiction and venue over all disputes between the
parties.
21. Attorney’s Fees And Costs: In any legal action to enforce this Agreement,
or arising out of the sale or licensing of Products hereunder, the prevail-
ing party shall be awarded all court costs and reasonable attorney’s fees
incurred.
22. Force Majeure: Intel shall not be liable to End User for any alleged loss or
damage resulting from the delivery of the Products being delayed by acts
of End User, acts of civil or military authority, governmental priorities,
earthquake, fire, flood, epidemic, quarantine, energy crisis, strike, labor
trouble, war, riot, accident, shortage, delays in transportation, or any
other causes beyond Intel’s reasonable control.
23. Excusable Delay: Neither party shall be liable to the other for any alleged
loss or a damage resulting from a delay in performance resulting from a
cause beyond the reasonable control of the party whose performance is
delayed.
24. Choice Of Language. The original of this Agreement is in English and End
User waives any right to have it written in any other language.
25. Notices. Any notice regarding non-performance, breach, termination, or
renewal required or permitted to be given under this Agreement shall be
given in writing and shall be hand delivered or deposited, postage pre-
paid, registered or certified mail, in the United States or other country’s
mail, or sent by express delivery, addressed to End User or Intel, as the
case may be, at the addresses stated on the Order or at such other
address as shall be given by either one to the other in writing. All other
notices may be sent by regular mail or facsimile. All notices shall be
deemed given and received on the earlier of actual delivery or three (3)
days from the date of postmark.
26. No Assignment: End User may not transfer or assign the Product or this
Agreement to another party without the prior written consent of Intel.
E-8
Download from Www.Somanuals.com. All Manuals Search And Download.
Glossary
This section defines terms and acronyms used throughout the Intel®
NetStructure™ 7110/7115 e-Commerce Accelerator User Guide.
Bypass
Cascading
Certificate
User action causing traffic to bypass 7110/7115 processing, done
either through the CLI bypass command or Bypass button on the
front panel of the 7110/7115.
A configuration of two or more 7110/7115s serially connected
together to accommodate larger e-Commerce traffic processing
(CPS) loads.
A digitally-signed token in an SSL-encrypted transaction containing
information including the issuer (Certificate Authority that issued the
certificate), the organization that owns the certificate, public key, the
validity period for the certificate, and the hostname.
Cipher
DNS
Any encryption algorithm, either symmetric or public key, operating
either as a data stream or divided into blocks.
Domain Name Server. A mechanism used in the Internet for
translating the names of host computers into addresses.
Flash
Permanent (non-volatile) storage for configuration changes.
Download from Www.Somanuals.com. All Manuals Search And Download.
G L O S S A R Y Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Fulfillment Server
HTTP
A server that stores content used to satisfy user requests.
Hypertext Transfer Protocol: the protocol used between a Web
browser and a server to request a document and transfer its contents.
HTTPS
Inline
HTTP exchanged over an SSL-encrypted session.
When the 7110/7115 is able to process SSL traffic, the Inline LED on
the front panel is lit (blinking or steadily illuminated).
IP
Internet Protocol
IP Address
A unique identifier for a node on an IP network. Expressed in “dotted
decimal” notation. For example: 10.0.0.1.
IP Service
A network-accessible, IP-accessible Application Protocol. For
example: HTTP, FTP, and the like.
ITM (Internet Traffic
Manager)
Intel® NetStructure™ 7140 and 7170 Traffic Director and the Intel®
NetStructure™ 7180 e-Commerce Director products used for load
balancing.
Key
A public key and private key pair used to encrypt/decrypt messages.
Key Strength
Length, in bits, of keys used in data encryption or authentication. For
example: 56, 128, 512.
Keypair
Matching public and private keys.
Load Balancing
The distribution of processing and communications activity across a
computer network so that no single device is overwhelmed. Load
balancing is particularly important for networks on which it is
difficult to predict the volume of requests likely to be issued to a
server. Busy Web sites typically employ two or more Web servers in
load balancing roles.
Port
In the context of TCP/IP sessions, a unique protocol-specific handle.
Private Key
The part of a key in a public key system that is kept secret and used
only by its owner. It is used for decrypting messages and for making
digital signatures.
Public Key
The part of a key in a public key system that is distributed widely, and
is not kept secure. Used for encryption or for verifying signatures.
Glossary-2
Download from Www.Somanuals.com. All Manuals Search And Download.
G L O S S A R Y Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Service
A service is an IP application paired with a port number. For
example: “HTTP:80.” This describes a service consisting of a
server's HTTP application listening on port 80. Another example of a
service: “FTP:21.”
Signing Request
SNMP
Required for a request for certificate authentication by a Certificate
Authority.
Simple Network Management Protocol. An application-layer Intenet
protocol by which multiple devices in a network can be monitored
and to some extent configured.
SSL (Secure Socket
Layer)
Protocol developed by Netscape for encrypted transmission over
TCP/IP networks, setting up a secure end-to-end link.
VeriSign§
A well-known certificate authority.
Glossary-3
Download from Www.Somanuals.com. All Manuals Search And Download.
G L O S S A R Y Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Notes
Glossary-4
Download from Www.Somanuals.com. All Manuals Search And Download.
Support Services
Intel offers a range of support services for your new product. You can learn about the options
available for your area by visiting the Intel® support Web site at http://www.intel.com/network/
service and choosing your geography.
Worldwide Access to Technical Support
Intel has technical support centers worldwide. Technicians who speak the local languages staff
many of the centers. Visit our Web site at http://support.intel.com.
North America only
For support, call (800) 838-7136 or (916) 377-7000.
Japan only
For support, call +81-298-47-0800.
Other areas
For support in other countries, use the following table to dial the toll-free support number. Using the
table, locate the country from which you are calling, dial the access number, await the dial tone and
then dial the listed 800 number.
Country
Dialing Information
Australia
Dial 1-800-881-011, await dial tone, dial 800-838-7136
Dial 10811, await dial tone, dial 800-838-7136
Dial 800-1111, await dial tone, dial 800-838-7136
Dial 000-117, await dial tone, dial 800-838-7136
3
China
Hong Kong
5
India
Download from Www.Somanuals.com. All Manuals Search And Download.
S U P P O R T
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Country
Dialing Information
2
Indonesia
Dial 001-801-10, await dial tone, dial 800-838-7136
Dial 0-911, await dial tone, dial 800-838-7136
Dial 800-0011, await dial tone, dial 800-838-7136
Dial 000-911, await dial tone, dial 800-838-7136
Dial 800-0111-111, await dial tone, dial 800-838-7136
Dial 430-430, await dial tone, dial 800-838-7136
Dial 0080-10288-0, await dial tone, dial 800-838-7136
Dial 0019-991-1111, await dial tone, dial 800-838-7136
Dial 022-903-011, await dial tone, dial 800-838-7136
Dial 0-800-100-10, await dial tone, dial 800-838-7136
Dial 8001-0010, await dial tone, dial 800-838-7136
Dial 9800-100-10, await dial tone, dial 800-838-7136
1
Korea
4
Malaysia
New Zealand
Singapore
Sri Lanka
1
Taiwan
5
Thailand
1 4
Austria
1
Belgium
Denmark
1
Finland
France (Includes Andorra)
Germany
Dial 19-0011, await dial tone, dial 800-838-7136
Dial 0130-0010, await dial tone, dial 800-838-7136
Dial 172-1011, await dial tone, dial 800-838-7136
Dial 06-022-9111, await dial tone, dial 800-838-7136
Dial 800-190-11, await dial tone, dial 800-838-7136
Dial 0-0-800-111-1111, await dial tone, dial 800-838-7136
Dial 05017-1-288, await dial tone, dial 800-838-7136
Dial 755-5042, await dial tone, dial 800-838-7136
Dial 900-99-00-11, await dial tone, dial 800-838-7136
Dial 020-795-611, await dial tone, dial 800-838-7136
1
Italy (Includes Vatican City)
1
Netherlands
Norway
1 3
Poland
3
Portugal
1 2 3
Russia
Spain
Sweden
Support-2
Download from Www.Somanuals.com. All Manuals Search And Download.
S U P P O R T
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User
Country
Dialing Information
1
Switzerland
Dial 0-800-550011, await dial tone, dial 800-838-7136
3
United Kingdom (Mercury)
Dial 0500-89-0011, await dial tone, dial 800-838-7136
Dial 0800-89-0011, await dial tone, dial 800-838-7136
Dial 0-800-99-0123, await dial tone, dial 800-838-7136
Dial 105-11, await dial tone, dial 800-838-7136
3
United Kingdom (BT)
RSA (South Africa)
Philippines
Vietnam
Dial 12010288, await dial tone, dial 800-838-7136
Dial 0080001001, await dial tone, dial 800-838-7136
Pakistan
Notes:
1
2
3
4
5
Public phones require coin or deposit
Use phones allowing international access
May not be available from every phone
Public phones require local phone payment through the call duration
Not available from public phones
Support-3
Download from Www.Somanuals.com. All Manuals Search And Download.
S U P P O R T
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Notes
Support-4
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
A
Subnet IP, subnet mask, specific port
Access Control 6-21
Administration Commands 5-44
Alarms
Network link status 7-8
Overload 7-7
Certificate Authority 3-7
Ciphers C-2
config save 4-4, 4-6
Configuration Commands 5-25
Utilization threshold 7-5
Automapping 3-21
Automapping with multiple port combi-
nations 3-22
and certificate 3-22
B
Cut and Paste 5-5
Blocking 3-23
All IPs, specific port 3-24
Delete block 3-25
Specific IP, specific port 3-23
D
delete map 4-4, 4-6
Download from Www.Somanuals.com. All Manuals Search And Download.
I N D E X
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
E
Logging Commands 5-47
F
Manual mapping 3-22
Mapping 3-21
Failure/Bypass modes B-1
Front panel LEDs A-2
G
N
Global site certificates 3-15
Network connections 2-3
Network link status alarm 7-8
H
O
Help 5-1
Overload alarm 7-7
I
Import
certificate 3-9, 3-13
import
key 4-5
Ingress routers 4-10
Input Editing Commands 5-4
Installation
Rack installation 2-2
Redirection for unsupported ciphers 3-
Remote Management 6-1
CLI commands 6-2
Rack mounting 2-2
Wiring connections 2-3
K
Limitations 6-2
Telnet 6-4
Keys 3-5
Telnet, changing port 6-5
Telnet, enabling/disabling 6-6
Index-2
Download from Www.Somanuals.com. All Manuals Search And Download.
I N D E X
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Telnet, local console 6-4
Telnet, remote console 6-5
Remote SSh sessions 6-6
S
Scenarios
Using the 7110/7115 with Ingress
and Egress Routers 4-10
Using the 7110/7115 with Multiple
er 4-3
SNMP 6-8
Private traps 6-16
Standard traps 6-16
Trap community string 6-20
Trap summary 6-16
Spill enable 4-8
Spilling 3-4
SSL Commands 5-12
SSL Processing 3-21
Status Commands 5-11
T
Telnet 6-4
Enabling/disabling 6-6
Throttling 3-4
Trap summary 6-16
U
Utilization threshold alarm 7-5
Index-3
Download from Www.Somanuals.com. All Manuals Search And Download.
I N D E X
Intel® NetStructure™ 7110/7115 e-Commerce Accelerator User Guide
Notes
Index-4
Download from Www.Somanuals.com. All Manuals Search And Download.
|