Intel Server P4304CR2LFKN User Manual

Intel® Server System P4000IP and  
Intel® Workstation System P4000CR Family  
Quick Installation User's Guide  
Thank you for buying an Intel® Server System. The following information will help you  
®
assemble your Intel Server System and install components.  
If you are not familiar with ESD [Electrostatic Discharge] procedures used during  
system integration, see the complete ESD procedures described in your Service Guide.  
This guide and other supporting documents are located on the web at:  
G49309-003  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
System Overview ...................................................................................................................................................... 1  
Intel® Server System P4308IP4LHGC............................................................................................ 1  
Intel® Server System P4308IP4LHJC ............................................................................................ 1  
Intel® Server System P4308IP4LHJCL .......................................................................................... 1  
Intel® Server System P4308IP4LHKC ............................................................................................ 2  
Intel® Server System P4208IP4LHGC............................................................................................ 2  
Intel® Server System P4216IP4LHJC ............................................................................................ 3  
Intel® Server System P4216IP4LHKC ............................................................................................ 3  
Intel® Server System P4224IP4LHKC ............................................................................................ 4  
Intel® Workstation System P4304CR2LFGN .............................................................................. 4  
Intel® Workstation System P4304CR2LFJN................................................................................ 5  
Intel® Workstation System P4304CR2LFJNL.............................................................................. 5  
Intel® Workstation System P4304CR2LFKN .............................................................................. 5  
Hot Swap Hard Drive Bay Options and HDD Numbering .................................................... 6  
General Installation Process ................................................................................................................................ 7  
Preparing the System ............................................................................................................................ 7  
Remove the Side Cover.......................................................................................................................... 7  
Remove the Air Duct .............................................................................................................................. 7  
Install the Processor(s) .......................................................................................................................... 7  
Install Heat Sink(s) .................................................................................................................................... 8  
Install DIMM Memory Modules............................................................................................................ 9  
Install Tool-less CD-ROM or DVD-ROM Drive .............................................................................. 9  
Install Hard Drive ....................................................................................................................................10  
Install PCI Card Assembly....................................................................................................................11  
Install Intel® Remote Management Module 4 NIC (optional)............................................12  
Install RMM4 EMI Cover (optional) ................................................................................................12  
Install Alternate Serial Port (optional) ........................................................................................12  
Install Intel® RAID Smart Battery (optional)..............................................................................13  
Install Second Power Supply Module (optional)......................................................................13  
Rack Mount Configuration (optional)............................................................................................13  
Install Feet (pedestal only) ................................................................................................................13  
Install Air Duct ..........................................................................................................................................14  
Install Side Cover ....................................................................................................................................14  
Finishing Up ................................................................................................................................................14  
Install Software ........................................................................................................................................14  
Reference .................................................................................................................................................................... 15  
HDD Cage Cable Connection.............................................................................................................. 15  
Front Panel Controls and Indicators.............................................................................................. 16  
Cable Routing Diagram ........................................................................................................................ 16  
i
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warning  
Warning  
Caution  
Tools Required  
Flat Blade  
screwdriver  
Read all caution and safety  
Observe normal ESD  
Installation and service  
statements in this document  
before performing any of the  
[Electrostatic Discharge]  
procedures during system  
integration to avoid possible  
damage to server board and/or  
other components.  
of this product to be  
performed only by  
instructions. Also see the Intel®  
Server Board and Server Chassis  
Safety Information document at:  
motherboards/server/sb/cs-010770  
.htm for complete safety information.  
qualified service personnel  
to avoid risk of injury from  
electrical shock or energy  
hazard.  
Phillips*  
screwdriver  
Anti-static  
wrist strap  
Intel is a registered trademark of Intel Corporation or its subsidiaries in the United States and other countries. *Other names and brands may be claimed as the  
property of others. Copyright © 2012, Intel Corporation. All rights reserved.  
Intel® Server System P4000IP Family Product Configuration  
System Fan  
Hard Drives  
Power Supply  
Intel® Server  
System  
Five  
Hot Swap  
System  
Fans  
(80 x 38 mm)  
P4308IP4LHGC  
P4308IP4LHJC  
P4308IP4LHJCL  
P4308IP4LHKC  
P4208IP4LHGC  
P4216IP4LHJC  
P4216IP4LHKC  
P4224IP4LHKC  
Intel® Workstation System P4000CR Family Product Configuration  
Intel®  
System Fan  
Two Fixed System Fans  
(120x38mm)  
Hard Drives  
Power Supply  
Workstation  
One Hot Swap One Hot Swap  
One Hot Swap  
CRPS 1600W  
System  
4 x 3.5 Fixed  
CRPS 750W  
CRPS 1200W  
P4304CR2LFGN  
P4304CR2LFJN  
P4304CR2LFJNL  
P4304CR2LFKN  
= Configuration Feature  
Thermal Operation and Configuration Requirements  
To keep the system operating within supported maximum thermal limits, the system must meet the following operating and configuration guidelines:  
• Ambient in-let temperature cannot exceed 35º C and should not remain at this maximum level for long periods of time. Doing so may affect  
long term reliability of the system.  
• The CPU-1 processor and CPU heatsink must be installed.  
DIMM Population on CPU-1: Install DIMMs in order; Channels A, B, C, and D. Start with 1st DIMM slot (blue) on each channel.  
DIMM Population on CPU-2: Install DIMMs in order; Channels E, F, G, and H. Start with 1st DIMM slot (blue) on each channel.  
• All hard drive bays must be populated. Hard drive carriers either can be populated with a hard drive or supplied drive blank.  
• The air duct must be installed at all times.  
• In single power supply configurations, the second power supply bay must have the supplied filler blank installed at all times.  
• The system top-cover must be installed at all times.  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Overview  
Intel® Server System P4308IP4LHGC  
750W Common Redundant Power Supply  
A
B
C
D
E
System Features and Components  
AC Input Power Connector  
I/O Ports  
Serial Port Knockout  
A Kensington* Cable Lock Mounting Hole  
PCI Add-in Board Slot Covers  
Knock-out Opening for I/O Modules  
Alternate RMM4 Knockout  
Opening for SPDIF Cable  
Padlock Loop  
F
A
B
C
D
E
G
H
I
J
K
L
M
N
O
P
Q
L
M
N
O
P
Q
R
S
T
H
J
RMM4 Knockout  
I
Hot-swap System Fan 5  
Front Control Panel  
Hot Swap System Fan 4  
5.25” Peripheral Bays  
F
K
Hot-swap System Fan 3  
One 8x3.5” Hot-swap HDD Cage  
G
R Hot-swap System Fan 2  
Hot Swap System Fan 1  
S
T
U
U
Air Duct  
PCI Card Retainer  
Intel® Server System P4308IP4LHJC(L)  
1200W Common Redundant Power Supply  
A
System Features and Components  
B AC Input Power Connector  
C I/O Ports  
Serial Port Knockout  
D
A Kensington* Cable Lock Mounting Hole  
E
A
B
C
D
E
F PCI Add-in Board Slot Covers  
G Knock-out Opening for I/O Modules  
H Alternate RMM4 Knockout  
L
M
N
O
P
Q
R
S
T
I
Opening for SPDIF Cable  
H
J
J
K
L
Padlock Loop  
I
RMM4 Knockout  
Hot-swap System Fan 5  
F
Front Control Panel  
M
N
O
P
Q
R
S
T
Hot-swap System Fan 4  
5.25" Peripheral Bays  
Hot-swap System Fan 3  
One 8x3.5” Hot-swap HDD Cage  
Hot-swap System Fan 2  
Hot-swap System Fan 1  
Air Duct  
K
G
U
PCI Card Retainer  
U
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Overview  
Intel® Server System P4308IP4LHKC  
1600W Common Redundant Power Supply  
A
B
C
D
E
F
G
H
I
System Features and Components  
AC Input Power Connecotor  
I/O ports  
Serial Port Knockout  
A
A Kensington Cable Lock Mounting Hole  
PCI Add-in Card Slot Covers  
Knock-out Opening for I/O Modules  
Alternate RMM4 Knockout  
Opening for SPDIF Cable  
Padlock Loop  
B
C
D
E
L
M
N
O
P
Q
R
S
T
H
J
I
J
K
L
RMM4 Knockout  
Hot Swap System Fan 5  
F
M Front Control Panel  
K
Hot Swap System Fan 4  
N
O
P
Q
G
5.25” Peripheral Bays  
Hot Swap System Fan 3  
One 8x3.5” Hot-swap HDD Cage  
U
R Hot-swap System Fan 2  
S Hot-swap System Fan 1  
T
Air Duct  
U PCI Card Retainer  
Intel® Server System P4208IP4LHGC  
750-W Common Redundant Power Supply  
A
B
C
D
E
System Features and Components  
AC Input Power Connector  
I/O Ports  
Serial Port Knockout  
A Kensington* Cable Lock Mounting Hole  
PCI Add-in Board Slot Covers  
Knockout Opening for I/O Module  
Alternate RMM4 Knockout  
Opening for SPDIF Cable  
Padlock Loop  
F
A
B
C
D
E
G
H
I
J
K
L
L
M
N
O
P
Q
R
S
T
H
J
RMM4 Knockout  
I
Hotswap System Fan 5  
Front Control Panel  
M
N
O
P
Q
R
S
T
Hotswap System Fan 4  
5.25" Peripheral Bays  
F
Hotswap System Fan 3  
One 8x2.5 Hot-swap HDD Cage  
K
G
Hot-swap System Fan 2  
Hot Swap System Fan 1  
Air Duct  
U
PCI Card Retainer  
U
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Overview  
Intel® Server System P4216IP4LHJC  
1200-W Common Redundant Power Supply  
A
System Features and Components  
B AC Input Power Connector  
C I/O Ports  
Serial Port Knockout  
D
A Kensington* Cable Lock Mounting Hole  
A
B
C
D
E
E
F
PCI Add-in Board Slot Covers  
G Knock-out opening for I/O modules  
H Alternate RMM4 Knockout  
L
M
N
O
P
Q
R
S
T
H
J
I
J
K
L
Opening for SPDIF Cable  
I
Padlock Loop  
RMM4 Knockout  
Hot-swap System Fan 5  
F
Front Control Panel  
M
N
O
P
Q
R
S
T
Hot-swap System Fan 4  
5.25" Peripheral Bays  
Hot-swap System Fan 3  
Air Duct  
K
G
U
Hot-swap System Fan 2  
Hot-swap System Fan 1  
Two 8 x 2.5" Hot-swap HDD Cage  
PCI Card Retainer  
U
Intel® Server System P4216IP4LHKC  
1600-W Common Redundant Power Supply  
A
System Features and Components  
B AC Input Power Connector  
C I/O Ports  
Serial Port Knockout  
D
E
A
A Kensington* Cable Lock Mounting Hole  
F
PCI Add-in Board Slot Covers  
B
G Knock-out opening for I/O modules  
H Alternate RMM4 Knockout  
I
J
K
C
D
E
L
M
N
O
P
Q
R
S
T
H
J
Opening for SPDIF Cable  
I
Padlock Loop  
RMM4 Knockout  
Hot-swap System Fan 5  
L
F
Front Control Panel  
M
N
O
P
Q
R
S
T
Hot-swap System Fan 4  
5.25" Peripheral Bays  
Hot-swap System Fan 3  
Air Duct  
K
G
U
Hot-swap System Fan 2  
Hot-swap System Fan 1  
Two 8 x 2.5" Hot-swap HDD Cage  
PCI Card Retainer  
U
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Overview  
Intel® Server System P4224IP4LHKC  
1600-W Common Redundant Power Supply  
A
B
C
D
E
F
G
H
I
System Features and Components  
AC Input Power Connector  
I/O Ports  
Serial Port Knockout  
A Kensington* Cable Lock Mounting Hole  
PCI Add-in Board Slot Covers  
Knock-out opening for I/O modules  
Alternate RMM4 Knockout  
Opening for SPDIF Cable  
Padlock Loop  
A
B
C
D
E
J
L
M
N
O
P
Q
R
S
T
H
J
RMM4 Knockout  
K
L
M
I
Hot-swap System Fan 5  
Frontt Control Panel  
5.25” Peripheral Bays  
N
O
P
Q
R
S
T
F
Hot-swap System Fan 4  
Hot-swap System Fan 3  
Air Duct  
K
G
Hot-swap System Fan 2  
Hot-swap System Fan 1  
Three 8x2.5" Hot-swap HDD Cage  
PCI Card Retainer  
U
U
Intel®WorkstationSystemP4304CR2LFGN  
750W Common Redundant Power Supply  
A
System Features and Components  
B AC Input Power Connector  
C I/O Ports  
Serial Port Knockout  
D
A Kensington* Cable Lock Mounting Hole  
E
F PCI Add-in Board Slot Covers  
G Knock-out Opening for I/O Modules  
H Alternate RMM4 Knockout  
A
B
C
D
E
I
Opening for SPDIF Cable  
J
K
L
M
Padlock Loop  
L
H
J
RMM4 Knockout  
I
M
N
O
Front Control Panel  
CPU Zone System Fan (Fan 2)  
5.25" Peripheral Bays  
N
O
P
Q
R
F
Air Duct  
P
Q
K
PCI Zone System Fan (Fan 1)  
G
Fixed Hard Driver Carrier Tray  
PCI Card Retainer  
R
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Overview  
Intel®WorkstationSystemP4304CR2LFJN(L)  
1200-W Common Redundant Power Supply  
A
B
C
D
E
System Features and Components  
AC Input Power Connector  
I/O Ports  
Serial Port Knockout  
A Kensington* Cable Lock Mounting Hole  
PCI Add-in Board Slot Covers  
Knock-out Opening for I/O Modules  
Alternate RMM4 Knockout  
Opening for SPDIF Cable  
Padlock Loop  
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
L
H
J
I
M
N
O
RMM4 Knockout  
F
Front Control Panel  
P
Q
CPU Zone System Fan (Fan 2)  
5.25" Peripheral Bays  
Air Duct  
K
G
R
PCI Zone System Fan (Fan 1)  
Fixed Hard Drive Carrier Tray  
PCI Card Retainer  
Intel®WorkstationSystemP4304CR2LFKN  
System Features and Components  
1600W Common Redundant Power Supply  
AC Input Power Connector  
I/O Ports  
A
B
C
D
E
Serial Port Knockout  
A
B
C
D
E
A Kensington* Cable Lock Mounting Hole  
PCI Add-in Board Slot Covers  
Knock-out Opening for I/O Modules  
Alternate RMM4 Knockout  
Opening for SPDIF Cable  
Padlock Loop  
F
G
H
I
J
K
L
M
N
O
P
Q
R
L
H
J
I
M
N
O
RMM4 Knockout  
F
Front Control Panel  
P
Q
CPU Zone System Fan (Fan 2)  
5.25" Peripheral Bays  
K
G
Air Duct  
R
PCI Zone System Fan (Fan 1)  
Fixed Hard Drive Carrier Tray  
PCI Card Retainer  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Overview  
Hot Swap Hard Drive Bay Options and HDD Numbering  
8 x 3.5"  
Hot-Swap  
Drive Cage  
8 x 2.5"  
Hot-Swap  
Drive Cage  
7
3
6
2
5
1
4
0
7 6 5 4 3 2 1 0  
16 x 2.5"  
Hot-Swap  
Drive Cage  
24 x 2.5"  
Hot-Swap  
Drive Cage  
20  
12  
23 22 21  
15 14 13  
19 18 17 16  
12  
15 14 13  
11 10 9 8  
11 10 9 8  
7 6 5 4 3 2 1 0  
7 6 5 4 3 2 1 0  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  

Insignia TV Mount NS HZ311 User Manual
Intel Computer Hardware MCS 80 85 User Manual
Intermec Time Clock PF2i User Manual
JVC CRT Television AV 1414EE AV 2134EE AV 1434EE AV 1434TEE AV 2104EE AV 2104TEE AV 2114EE AV 2134TEE AV 2124EE User Manual
JVC CRT Television AV 27430 User Manual
Karcher Pressure Washer K 320 M User Manual
KitchenAid Security Camera KAWE564W User Manual
KitchenAid Ventilation Hood KHLU162MSS0 User Manual
Kramer Electronics Marine Radio VM 1110xl User Manual
Krell Industries CD Player Evolution 505 User Manual