Intel Server L440GX User Manual

L440GX+ Server Board  
Product Guide  
Order Number: 722077-005  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
1 Description  
Server Board Features..........................................................................................................7  
Back Panel Connectors................................................................................................8  
Server Board Connector and Component Locations.....................................................9  
Processor...................................................................................................................10  
Memory ....................................................................................................................10  
440GX Host Bridge / Memory Controller.............................................................................11  
Peripherals..........................................................................................................................11  
Super I/O Chip ...........................................................................................................11  
Add-in Board Slots..............................................................................................................12  
Video ..................................................................................................................................13  
SCSI Controller...................................................................................................................13  
IDE Controller .....................................................................................................................13  
Network Controller ..............................................................................................................14  
Keyboard and Mouse..........................................................................................................14  
ACPI ...................................................................................................................................14  
Server Management ...........................................................................................................15  
Baseboard Management Controller (BMC).................................................................15  
Emergency Management Port Console......................................................................16  
Platform Event Paging................................................................................................16  
Security...............................................................................................................................17  
Security with Mechanical Locks and Monitoring .........................................................17  
Software Locks...........................................................................................................17  
2 Upgrading  
Tools and Supplies Needed................................................................................................21  
Warnings and Cautions.......................................................................................................21  
Server Board.......................................................................................................................22  
Installing the Server Board .........................................................................................22  
Removing the Server Board .......................................................................................23  
Memory...............................................................................................................................24  
Installing DIMMs.........................................................................................................24  
Removing DIMMs.......................................................................................................25  
Processors..........................................................................................................................26  
Removing a Processor...............................................................................................26  
Installing a Processor.................................................................................................28  
Replacing the Back up Battery............................................................................................30  
3 Configuration Software and Utilities  
Hot Keys.............................................................................................................................33  
Power On Self Test (POST)................................................................................................34  
Using BIOS Setup...............................................................................................................35  
Record Your Setup Settings.......................................................................................35  
If You Cannot Access Setup.......................................................................................35  
Starting Setup ............................................................................................................36  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setup Menus..............................................................................................................36  
Main Menu .................................................................................................................37  
Advanced Menu .........................................................................................................40  
Security Menu ............................................................................................................43  
Server Menu...............................................................................................................44  
Boot Menu..................................................................................................................48  
Exit Menu...................................................................................................................50  
Using the System Setup Utility............................................................................................50  
When to Run the System Setup Utility........................................................................51  
What You Need to Do ................................................................................................51  
Running the SSU .......................................................................................................52  
Customizing the SSU .................................................................................................54  
Launching a Task.......................................................................................................54  
Resource Configuration Add-in (RCA) Window ..........................................................55  
Multiboot Options Add-in............................................................................................56  
Security Add-in...........................................................................................................57  
SEL Manager Add-in..................................................................................................58  
FRU Manager Add-in .................................................................................................59  
SDR Manager Add-in .................................................................................................60  
Exiting the SSU..........................................................................................................60  
Platform Event Paging ........................................................................................................61  
Using Platform Event Paging......................................................................................61  
Emergency Management Port Console...............................................................................62  
How EMP Console Works ..........................................................................................63  
Requirements.............................................................................................................65  
Setting up the Server for the EMP..............................................................................66  
Main EMP Console Window.......................................................................................67  
Server Control Operations..........................................................................................68  
Phonebook.................................................................................................................71  
Management Plug-ins ................................................................................................72  
FRUSDR Load Utility ..........................................................................................................75  
When to Run the FRUSDR Load Utility ......................................................................75  
What You Need to Do ................................................................................................75  
How You Use the FRUSDR Load Utility .....................................................................76  
Upgrading the BIOS............................................................................................................79  
Preparing for the Upgrade..........................................................................................79  
Upgrading the BIOS ...................................................................................................80  
Recovering the BIOS..................................................................................................81  
Changing the BIOS Language....................................................................................81  
Using the Firmware Update Utility.......................................................................................82  
Running the Firmware Update Utility..........................................................................82  
Installing Video Drivers .......................................................................................................82  
Using the Adaptec SCSI Utility............................................................................................83  
Running the SCSI Utility.............................................................................................83  
iv  
Contents  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 Solving Problems  
Resetting the System..........................................................................................................85  
Fault Resilient Booting........................................................................................................85  
Initial System Startup..........................................................................................................85  
Checklist ....................................................................................................................86  
Running New Application Software.....................................................................................86  
Checklist ....................................................................................................................86  
After the System Has Been Running Correctly....................................................................87  
Checklist ....................................................................................................................87  
More Problem Solving Procedures......................................................................................88  
Preparing the System for Diagnostic Testing..............................................................88  
Monitoring POST........................................................................................................88  
Verifying Proper Operation of Key System Lights.......................................................88  
Confirming Loading of the Operating System .............................................................88  
Specific Problems and Corrective Actions...........................................................................89  
Power Light Does Not Light........................................................................................89  
No Characters Appear on Screen...............................................................................89  
Characters Are Distorted or Incorrect.........................................................................90  
System Cooling Fans Do Not Rotate Properly............................................................90  
Diskette Drive Activity Light Does Not Light................................................................91  
Hard Disk Drive Activity Light Does Not Light.............................................................91  
CD-ROM Drive Activity Light Does Not Light..............................................................91  
Cannot Connect to a Server.......................................................................................92  
Problems with Network...............................................................................................92  
PCI Installation Tips ...................................................................................................93  
Problems with Application Software ....................................................................................93  
Bootable CD-ROM Is Not Detected.....................................................................................93  
Error and Informational Messages ......................................................................................94  
Port-80 Codes and Countdown Codes .......................................................................94  
POST Error Codes and Messages......................................................................................94  
5 Technical Reference  
Connectors .........................................................................................................................96  
ATX Style Front Panel Connector...............................................................................97  
Main Power Connector...............................................................................................98  
Fan Interface..............................................................................................................98  
Server Board Jumpers ........................................................................................................99  
General Procedure to Change Jumper Setting.........................................................100  
CMOS Jumper .........................................................................................................101  
Password Jumper.....................................................................................................101  
Recovery Boot Jumper.............................................................................................102  
Boot Block Write Protect Jumper..............................................................................102  
FRB Timer Enable Jumper.......................................................................................103  
Chassis Intrusion Detection Jumper.........................................................................103  
6 Regulatory and Integration Information  
Regulatory Compliance.....................................................................................................105  
Installation Instructions......................................................................................................106  
Ensure EMC.............................................................................................................106  
L440GX+ Server Board Product Guide  
v
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ensure Host Computer and Accessory Module Certifications...................................107  
Prevent Power Supply Overload...............................................................................107  
Place Battery Marking on Computer.........................................................................108  
Use Only for Intended Applications ..........................................................................108  
Installation Precautions.....................................................................................................108  
7 Equipment Log and Power Consumption Worksheets  
Equipment Log..................................................................................................................109  
Current Usage..........................................................................................................111  
Calculating Power Consumption...............................................................................111  
Index ....................................................................................................................................115  
Figures  
1.  
2.  
3.  
4.  
5.  
6.  
7.  
8.  
9.  
Back Panel Connectors................................................................................................8  
Server Board Connector and Component Locations ....................................................9  
Server Board Screw Hole Locations...........................................................................23  
Installing DIMMs.........................................................................................................25  
Installing a Processor.................................................................................................27  
Removing a Termination Board..................................................................................28  
Replacing the Lithium Battery.....................................................................................31  
System Setup Utility Main Window.............................................................................53  
EMP Console in Command State...............................................................................63  
10. EMP Console in Redirect State..................................................................................64  
11. Connect Dialog...........................................................................................................69  
12. Power On/Off Dialog ..................................................................................................70  
13. Reset Dialog ..............................................................................................................70  
14. Phonebook Dialog......................................................................................................71  
15. Connector Locations ..................................................................................................96  
16. ATX Style Front Panel Connector...............................................................................97  
17. Jumper Locations.......................................................................................................99  
Tables  
1.  
Server Board Features.................................................................................................7  
NIC LEDs.....................................................................................................................8  
Software Security Features........................................................................................19  
Configuration Utilities .................................................................................................33  
Hot Keys ...................................................................................................................33  
EMP Console Access Modes (Server configured for console redirection) ..................64  
EMP Console Access Modes (Server not configured for console redirection) ............65  
ATX Style Front Panel Connector Pinout....................................................................97  
Main Power Connector Pinout....................................................................................98  
2.  
3.  
4.  
5.  
6.  
7.  
8.  
9.  
10. Fan Connector Pinout ................................................................................................98  
11. Server Board Jumper Summary.................................................................................99  
12. Safety Regulations...................................................................................................105  
13. EMC Regulations .....................................................................................................105  
14. Power Usage Worksheet 1.......................................................................................112  
15. Power Usage Worksheet 2.......................................................................................113  
vi  
Contents  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1 Description  
Server Board Features  
Table 1.  
Feature  
Server Board Features  
Description  
Installed: Up to two Intel® Pentium® II or Pentium III processors (with 100 MHz  
Processor  
system bus) operating at 1.8 V to 3.5 V. The server board’s voltage regulator is  
automatically programmed by the processor’s VID pins to provide the required  
voltage.  
Memory (DRAM)  
Four 72 bit sockets for 168-pin, gold contact, 100 MHz, PC/100 compliant, ECC  
or non-ECC, registered or unbuffered, SDRAM dual inline memory  
modules (DIMM).  
Video Memory  
PCI bus  
Installed: 2 MB of video memory.  
Four standard PCI (PCI-33/32 bit) expansion slots for add-in boards. 1x32 bit  
PCI bus. Embedded devices: Video Controller, Network Interface Controller  
(NIC), and SCSI controller.  
Two PCI-66 MHz 32 bit 5 Volt expansion slots (backward compatible to PCI-33  
MHz 32 bit).  
ISA bus  
One ISA expansion slot for an add-in board. Embedded PC-compatible support  
(serial, parallel, mouse, keyboard, diskette, and Plug and Play features).  
Server Management  
Thermal/voltage monitoring and error handling.  
Real time clock/calendar (RTC).  
Front panel controls and indicators (LEDs).  
System Setup Utility (SSU).  
Basic Input/Output System (BIOS), Power On Self Test (POST), and Setup  
stored in flash memory.  
Graphics  
SCSI  
Integrated onboard Cirrus LogicCL-GD5480 super video graphics array  
(SVGA) controller.  
AdaptecAIC-7896, supporting onboard Ultra2 (LVD) wide and Ultra-wide SCSI  
interfaces. Support for the Adaptec ARO-1130U2 RAIDportIII card is built into  
PCI slot 4.  
Integrated onboard NIC, an Intel® 82559 single chip PCI LAN controller for 10 or  
100 Mbps TX Fast Ethernet networks. RJ-45 Ethernet connector and indicator  
LEDs at I/O back panel.  
Network  
System I/O  
PS/2-compatible keyboard and mouse ports, 6 pin DIN.  
Advanced parallel port, supporting Enhanced Parallel Port (EPP) level 1.7 and  
1.9, ECP, compatible 25 pin.  
VGA video port, 15 pin.  
Two serial ports, 9 pin.  
RJ-45 Ethernet port.  
Two USB ports.  
Form Factor  
Server ATX form factor, 12 ´ 13 inches, ATX 2.01 compliant I/O.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Back Panel Connectors  
Figure 1. Back Panel Connectors  
A.  
B.  
Mouse connector  
Keyboard connector  
C. Parallel Port connector  
D. Serial Port connectors  
E.  
F.  
Network connector  
Green NIC LED  
G. Orange NIC LED  
H. USB connectors  
I.  
Video connector  
Table 2.  
NIC LEDs  
NIC LED Color  
If it's on  
If it's blinking  
If it's off  
Orange  
NA  
10 Mbps network connection.  
100 Mbps network  
connection.  
Green  
Not linked to network.  
Linked to network, Linked to network, sending or  
no network traffic. receiving data.  
8
Description  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Server Board Connector and Component Locations  
Figure 2. Server Board Connector and Component Locations  
A. Fansink connector 2  
B. Secondary processor  
C. Fansink connector 1  
D. Primary processor  
E. DIMM slots  
S. Server monitor module (SMM)  
connector  
T. External Wake on LAN connector  
U. Ultra2/LVDS SCSI connector  
V. Hard drive LED connector  
W. Adaptec ARO-1130U2 RAID Port III  
F. Main power connector  
G. ATX Aux power connector  
H. Fan connector FAN2A  
I. Floppy connector  
connector/PCI slot 4  
X. Intelligent Chassis Management Bus  
(ICMB) header  
Y. ISA connector  
J. IDE connectors  
Z. Chassis intrusion connector  
AA. PCI-33/32 connectors  
BB. PCI-66/32 connectors  
CC. Fan connector FAN2B  
DD. Video connector  
K. ATX front panel connector  
L. Front panel connector, 16 pin  
M. Battery  
N. Isolated Server Management  
(ISOL) IMB (Intelligent  
EE. USB connectors  
Management Bus) connector  
FF. NIC connector  
O. Jumper block  
GG.Serial port connector (default COM 1)  
HH. Parallel port connector  
II. Serial port connector (default COM 2)  
JJ. Mouse/keyboard connectors  
P. Jumper block  
Q. Fan connector 1  
R. Ultra Wide SCSI connector  
L440GX+ Server Board Product Guide  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Processor  
Each Pentium II or Pentium III processor is packaged in a cartridge. The cartridge includes the  
processor core with an integrated 16 KB primary (L1) cache, the secondary (L2) cache, and a back  
cover.  
The processor implements the MMXtechnology and maintains full backward compatibility with  
the 8086, 80286, Intel386, Intel486, Pentium, Pentium Pro and previous Pentium II processors.  
The processor’s numeric coprocessor significantly increases the speed of floating point operations  
and complies with ANSI/IEEE standard 754-1985.  
Each processor cartridge connects to the server board through a 242 pin edge connector. The  
cartridge is secured by a retention mechanism attached to the server board. Depending on  
configuration, your server may have one or two processors.  
The processor external interface is MP (Multi-Processor) ready and operates at 100 MHz. The  
processor contains a local APIC (Advanced Programmable Interrupt Controller) section for  
interrupt handling in MP and UP (Uni-Processor) environments.  
The second level cache is located on the substrate of the S.E.C. cartridge. The cache includes burst  
pipelined synchronous static RAM (BSRAM). The L2 cache is offered in 512 KB configurations  
only, with error correcting code (ECC) that operates at half the core clock rate.  
NOTE  
/
If you install a processor that is 550 MHz or faster, and you use the server  
management feature board, you must run the FRUSDR update utility.  
Memory  
Only 100 MHz PC/100 ECC or Non-ECC SDRAM is supported by the server board. Memory is  
partitioned as four banks of SDRAM DIMMs, each providing 72 bits of noninterleaved memory  
(64 bit main memory plus ECC):  
·
·
Install from 64 MB to 2 GB of memory, using registered DIMMs.  
Install from 32 MB to 1 GB of memory, using unbuffered DIMMs.  
Memory should be added in order from slot 1 to slot 4.  
NOTE  
/
Do not mix registered and unbuffered memory. Non ECC memory may be  
installed but ECC memory is recommended in a server environment. Mixing  
Non-ECC memory and ECC memory causes all ECC features to be disabled.  
The controller automatically detects, sizes, and initializes the memory array, depending on the type,  
size, and speed of the installed DIMMs, and reports memory size and allocation to the server via  
configuration registers.  
10  
Description  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTE  
/
Use DIMMs that have been tested for compatibility with the server board.  
Contact your sales representative or dealer for a current list of approved  
memory modules. Check the Intel Customer Support website for the latest  
tested memory list:  
http://support.intel.com/support/motherboards/server/l440gx/compat.htm  
440GX Host Bridge / Memory Controller  
®
The L440GX+ is designed around the Intel 82440GX AGPSet (440GX). This device provides  
100MHz processor host bus interface support, DRAM controller, PCI bus interface, AGP interface  
(used on L440GX+ for PCI-66/5V), and power management functions. The host bus/memory  
interface in the 440GX is optimized for 100MHz operation, using 100MHz SDRAM main memory.  
The PCI interface is PCI 2.1-compliant, providing a 33 MHz / 5V signaling environment for  
embedded controllers and slots in the single PCI segment on L440GX+. The 440GX memory  
controller supports up to 2 GB of ECC or Non-ECC memory, using PC/100 compliant Synchronous  
DRAM (SDRAM) devices on DIMM plug-in modules. ECC can detect and correct single-bit  
errors, and detect multiple-bit errors.  
Peripherals  
Super I/O Chip  
The National87309 device supports two serial ports, one parallel port, diskette drive,  
PS/2-compatible keyboard and mouse. The server board provides a connector interface for  
each port.  
Serial Ports  
Each serial port can be set to one of four different COMx ports and can be enabled separately.  
When enabled, each port can be programmed to generate edge or level sensitive interrupts. When  
disabled, serial port interrupts are available to add-in boards.  
Parallel Port  
The 87309 provides one IEEE 1284-compatible 25 pin bidirectional EPP (supporting levels 1.7  
and 1.9). BIOS programming of the 87309 registers enable the parallel port and determine the port  
address and interrupt. ECP mode is supported with 2 possible DMA channels. When disabled, the  
interrupt is available to add-in boards.  
L440GX+ Server Board Product Guide  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Add-in Board Slots  
The server board has one full length ISA bus connector. ISA features:  
·
·
·
·
·
·
Bus speed up to 8.33 MHz  
16 bit memory addressing  
Type A transfers at 5.33 Mbps  
Type B transfers at 8 Mbps  
8 or 16 bit data transfers  
Plug and Play ready  
The server board has four full length standard PCI (PCI-33/32 bit) connectors. PCI features:  
·
·
·
·
·
·
·
Bus speed up to 33 MHz  
32 bit memory addressing  
5 V signaling environment  
Burst transfers of up to 133 Mbps  
8, 16, or 32 bit data transfers  
Plug and Play ready  
Parity enabled  
The server board has two full length PCI-66 universal connectors (5 volt/3.3 volt cards designed for  
the 3.3v connector -cards with only one notch- will not fit). PCI features:  
·
·
·
·
·
·
·
Bus speed up to 66 MHz  
32 bit memory addressing  
5 V/3.3 V signaling environment  
Burst transfers of up to 266 Mbps  
8, 16, or 32 bit data transfers  
Plug and Play ready  
Parity enabled  
NOTE  
/
If you install a PCI-33 card into one of the PCI-66 slots, the bus speed for  
both slots will be lowered to 33 MHz.  
The components on some full length cards installed in slot 6 may interfere  
with the DIMM connector latches.  
12  
Description  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Video  
The onboard, integrated Cirrus Logic CL-GD5480 64 bit VGA chip contains an SVGA controller  
that is fully compatible with these video standards: CGA, EGA, HerculesGraphics, MDA, and  
VGA. The standard configuration comes with 2 MB of 10 ns onboard Synchronous Graphics  
Memory (SGRAM). The video controller supports pixel resolutions of up to 1600 x 1200 and up to  
16.7 Million colors.  
The SVGA controller supports analog VGA monitors (single and multiple frequency, interlaced  
and noninterlaced) with a maximum vertical retrace noninterlaced frequency of 100 Hz.  
You cannot add video memory to the server board. Depending on the environment, the controller  
displays up to 16.7 M colors in some video resolutions. It also provides hardware accelerated bit  
block transfers (BITBLT) of data.  
SCSI Controller  
The embedded Adaptec AIC-7896 dual function SCSI controller provides both Ultra2 (LVDS)  
wide and Ultra wide SCSI interfaces as two independent PCI functions. PCI slot 4 is  
RAID-upgradeable, providing additional support for the ARO1130U2 RAIDport III controller by  
Adaptec.  
The SCSI bus is terminated on the server board with active terminators that cannot be disabled.  
The onboard device must always be at one end of the bus. The device at the end of the cable must  
be terminated. LVDS devices generally do not have termination capabilities. Non-LVDS devices  
generally are terminated through a jumper or resistor pack. The SCSI cable (Intel Part Number  
745854-003) included with your server board (or integrator’s kit) has been modified to include  
active termination. The cable is capable of supporting both Ultra-2 and non-Ultra-2 SCSI devices.  
Proper termination of the SCSI bus is required for stable operation of SCSI devices. When  
attaching any SCSI device to the cable, verify that they are not terminated. This is usually a  
configurable option using a jumper or terminator block on the device. Check the documentation  
that came with your SCSI device to verify this option. Termination of the SCSI bus is implemented  
using the active termination on the server board along with the active termination at the end of the  
SCSI cable.  
IDE Controller  
IDE is a 16 bit interface for intelligent disk drives with disk controller electronics onboard. The  
PCI/ISA/IDE Accelerator, also known as PIIX4e, is a multifunction device on the server board that  
acts as a PCI based Fast IDE controller. The device controls:  
·
·
·
·
·
·
PIO and IDE DMA/bus master operations  
Mode 4 timings  
Transfer rates up to 33 MB/s  
Buffering for PCI/IDE burst transfers  
Master/slave IDE mode  
Up to two devices per channel; two channels, IDE0 and IDE1  
L440GX+ Server Board Product Guide  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTE  
/
18 inch maximum length of IDE cable on each channel: You can connect  
an IDE signal cable, up to a maximum of 18 inches each, to each  
IDE connector on the server board. Each cable can support two devices, one  
at the end of the cable and one 6 inches from the end of the cable.  
Network Controller  
The server board includes a 10BASE-T/100BASE-TX network solution based on the Intel 82559  
single chip Fast Ethernet PCI Bus Controller. As a PCI bus master, the controller can burst data at  
up to 132 MB/s. The controller contains two receive and transmit FIFO buffers that prevent data  
overruns or underruns while waiting for access to the PCI bus. The controller has the following:  
·
32 bit PCI bus master interface (direct drive of bus), compatible with PCI Bus Specification,  
Revision 2.1  
·
Chained memory structure with improved dynamic transmit chaining for enhanced  
performance  
·
·
·
·
·
Programmable transmit threshold for improved bus utilization  
Early receive interrupt for concurrent processing of receive data  
Onchip counters for network management  
Autodetect and autoswitching for 10 or 100 Mbps network speeds  
Support for both 10 Mbps and 100 Mbps networks, capable of full or half duplex, with back-to-  
back transmit at 100 Mbps  
The network status LEDs on the server board indicate:  
·
·
·
Transmit/receive activity on the LAN  
Valid link to the LAN  
10/100 Mbps transfer mode  
Keyboard and Mouse  
The keyboard/mouse controller is PS/2-compatible. The server may be locked automatically if  
there is no keyboard or mouse activity for a predefined length of time, if specified through the  
System Setup Utility (SSU). Once the inactivity (lockout) timer has expired, the keyboard and  
mouse do not respond until the previously stored password is entered.  
ACPI  
The L440GX+ supports the Advanced Configuration and Power Interface (ACPI) as defined by the  
ACPI 1.0 and PC97 specifications. An ACPI aware operating system can put the system into a  
state where the hard drives spin down, the system fans stop, and all processing is halted. However,  
the power supply will still be on and the processors will still be dissipating some power, so the  
power supply fan and processor fans will still run.  
The L440GX+ supports sleep states s0, s1, s4, and s5. With future versions of Microsoft  
Windows9X that support ACPI, the BIOS will only support sleep states s0, s1, and s5. With  
14  
Description  
Download from Www.Somanuals.com. All Manuals Search And Download.  
future versions of Microsoft Windows NTx that support ACPI, the BIOS will support sleep states  
s0, s1, s4, and s5.  
·
·
s0: Normal running state.  
s1: Processor sleep state. No context will be lost in this state and the processor caches will  
maintain coherency.  
·
s4: Hibernate or Save to Disk: The memory and machine state are saved to disk. Pressing the  
power button or other wakeup event will restore the system state from the disk and resume  
normal operation. This assumes that no hardware changes have been made to the system while  
it was off.  
·
s5: Soft off: Only the RTC section of the PIIX4 and the BMC are running in this state.  
CAUTION  
The system is off only when the AC power is disconnected.  
Server Management  
Server Management features are implemented using one microcontroller.  
Baseboard Management Controller (BMC)  
All server management functionality is concentrated in the BMC. The BMC and associated  
circuitry are powered from + 5V_Standby, which remains active when server power is switched off  
and the server is still plugged into AC power.  
One major function of the BMC is to autonomously monitor system management events, and log  
their occurrence in the nonvolatile System Event Log (SEL). These include events such as  
overtemperature and overvoltage conditions, fan failure, or chassis intrusion. To enable accurate  
monitoring, the BMC maintains the nonvolatile Sensor Data Record (SDR), from which sensor  
information can be retrieved. The BMC provides an ISA host interface to SDR sensor information,  
so software running on the server can poll and retrieve the server's current status.  
SEL contents can be retrieved after system failure, for analysis by field service personnel using  
server management software tools such as Intel Server Control available on the CD-ROM that ships  
with the L440GX+ server board or from the Intel Customer Support website:  
http//support.intel.com/support/motherboards/server/l440gx  
Because the BMC is powered by 5V_Standby, SEL and SDR information are also available via the  
IMB (Intelligent Management Bus). An Emergency Management Card, such as the  
®
®
Intel LANDesk SMM (Server Monitor Module) card available with the LANDesk Server  
Manager Pro package, can obtain the SEL and make it remotely accessible using a LAN or  
telephone line connection. While it receives the proper current, the BMC does the following:  
·
·
·
·
·
Monitors server board temperature and voltage  
Monitors processor presence and controls FRB  
Detects and indicates baseboard fan failure  
Manages the SEL interface  
Manages the SDR Repository interface  
L440GX+ Server Board Product Guide  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
·
·
·
·
·
·
·
·
Monitors the SDR/SEL timestamp clock  
Manages the server board Field Replaceable Unit (FRU) information interface  
Monitors the system management watchdog timer  
Monitors the periodic SMI timer  
Manages front panel NMI handling  
Monitors the event receiver  
Manages the ISA host and IMB interface  
Controls secure mode, including video blanking, floppy write-protect monitoring, and front  
panel lock/unlock initiation  
·
·
Manages the sensor event initialization agent  
Controls Wake on LAN via Magic Packetsupport  
Emergency Management Port Console  
The Emergency Management Port (EMP) Console provides an interface to the Emergency  
Management Port (EMP). This interface allows remote server management via a modem or direct  
(serial port to serial port) connection.  
The server control operations available with EMP Console are:  
·
·
·
Connecting to remote servers  
Powering the server on or off  
Resetting the server  
The EMP Console uses three management plug-ins to monitor the server:  
·
·
·
SEL Viewer  
SDR Viewer  
FRU Viewer  
The EMP Console also has Phonebook plug-in that can be used to create and maintain a list of  
servers and their phone numbers.  
NOTE  
/
EMP and PEP (Platform Event Paging) share your modem. PEP has priority  
over all applications except EMP. If an alert occurs, PEP will reset your  
modem and page you.  
Platform Event Paging  
With Platform Event Paging (PEP), your server can be configured to automatically dial up a paging  
service and page you when a platform event occurs. Platform events include temperature out-of-  
range, voltage out-of-range, chassis intrusion, fan failure, etc.  
If PEP is enabled and the BMC receives or detects a new event, it automatically sends a page. It  
can send a page if the processors are down or if the system software is unavailable.  
PEP needs an external modem connected to the server's EMP (Emergency Management Port) serial  
connection. This is typically the COM2 serial connector.  
16  
Description  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Security  
To help prevent unauthorized entry or use of the server, Intel Server Control server management  
software monitors the system intrusion switch.  
Security with Mechanical Locks and Monitoring  
If installed, you can activate the chassis intrusion alarm switch. When the side door is opened, the  
switch transmits an alarm signal to the server board, where BMC firmware and server management  
software process the signal. The system can be programmed to respond to an intrusion by  
powering down or by locking the keyboard, for example.  
Software Locks  
The BIOS Setup and the System Setup Utility (SSU) provide a number of security features to  
prevent unauthorized or accidental access to the system. Once the security measures are enabled,  
you can access the system only after you enter the correct password(s). For example:  
·
Enable the keyboard lockout timer so that the server requires a password to reactivate the  
keyboard and mouse after a specified time out period¾1 to 120 minutes.  
Set and enable an administrative password.  
Set and enable a user password.  
Set secure mode to prevent keyboard or mouse input and to prevent use of the front panel reset  
and power switches.  
·
·
·
·
·
·
Activate a hot key combination to enter secure mode quickly.  
Disable writing to the diskette drive when secure mode is set.  
Disable access to the boot sector of the operating system hard disk drive.  
Using Passwords  
You can set either the user password, the administrator password, or both passwords. If only the  
user password is set, you:  
·
·
Must enter the user password to enter BIOS Setup or the SSU.  
Must enter the user password to boot the server if Password on Boot is enabled in either the  
BIOS Setup or SSU.  
·
Must enter the user password to exit secure mode.  
If only the administrator password is set, you:  
·
·
Must enter the administrator password to enter BIOS Setup or the SSU.  
Must enter the administrator password to boot the server if Password on Boot is enabled in  
either the BIOS Setup or SSU.  
·
Must enter the administrator password to exit secure mode.  
If both passwords are set, you:  
·
May enter the user password to enter BIOS Setup or the SSU. However, you will not be able to  
change many of the options.  
·
Must enter the administrator password if you want to enter BIOS Setup or the SSU and have  
access to all of the options.  
L440GX+ Server Board Product Guide  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
·
·
May enter either password to boot the server if Password on Boot is enabled in either the BIOS  
Setup or SSU.  
May enter either password to exit secure mode.  
Secure Mode  
Configure and enable the secure boot mode by using the SSU. When secure mode is in effect:  
·
You can boot the server and the operating system will run, but you must enter the user  
password to use the keyboard or mouse.  
·
You cannot turn off system power or reset the server from the front panel switches.  
Secure mode has no effect on functions enabled via the Server Manager Module or power control  
via the real time clock.  
Taking the server out of secure mode does not change the state of system power. That is, if you  
press and release the power switch while secure mode is in effect, the system will not be powered  
off when secure mode is later removed. However, if the front panel power switch remains  
depressed when secure mode is removed, the server will be powered off.  
18  
Description  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Summary of Software Security Features  
The table below lists the software security features and describes what protection each offers. In  
general, to enable or set the features listed here, you must run the SSU and go to the Security  
Subsystem Group, menu. The table also refers to other SSU menus and to the Setup utility.  
Table 3.  
Feature  
Software Security Features  
Description  
Secure mode  
How to enter secure mode:  
·
Setting and enabling passwords automatically places the system in secure  
mode.  
·
If you set a hot-key combination (through the SSU or Setup), you can secure  
the system simply by pressing the key combination. This means you do not  
have to wait for the inactivity time-out period.  
When the system is in secure mode:  
The server can boot and run the operating system, but mouse and keyboard  
input is not accepted until the user password is entered.  
At boot time, if a CD is detected in the CD-ROM drive or a diskette in drive A, the  
system prompts for a password. When the password is entered, the server  
boots from CD or diskette and disables the secure mode.  
If there is no CD in the CD-ROM drive or diskette in drive A, the server boots  
from drive C and automatically goes into secure mode. All enabled secure mode  
features go into effect at boot time.  
To leave secure mode: Enter the correct password(s).  
Disable writing to diskette  
In secure mode, the server will not boot from or write to a diskette unless a  
password is entered. To set this feature, use the SSU Security Subsystem  
Group.  
To write protect access to diskette whether the server is in secure mode or not,  
use the Setup main menu, Floppy Options, and specify Floppy Access as  
read only.  
Disable the power and  
reset buttons  
Enable the feature through the SSU. Then the power and reset buttons are  
disabled when the server is in secure mode.  
Set a time out period so  
that keyboard and mouse  
input are not accepted  
Specify and enable an inactivity time out period of from 1 to 120 minutes.  
If no keyboard or mouse action occurs for the specified period, attempted  
keyboard and mouse input will not be accepted.  
Also, screen can be  
blanked, and writes to  
diskette can be inhibited  
The monitor display will go blank, and the diskette drive will be write protected  
(if these security features are enabled through Setup or the SSU).  
To resume activity: Enter the correct password(s).  
Control access to using  
the SSU: set  
To control access to setting or changing the system configuration, set an  
administrative password and enable it through Setup or the SSU.  
administrative password  
If both the administrative and user passwords are enabled, either can be used to  
boot the server or enable the keyboard and/or mouse, but only the administrative  
password will allow Setup and the SSU to be changed.  
To disable a password, change it to a blank entry or press CTRL-D in the  
Change Password menu of the Administrative Password Option menu found in  
the Security Subsystem Group.  
To clear the password if you cannot access Setup or the SSU, change the Clear  
Password jumper (see Chapter 5).  
continued  
L440GX+ Server Board Product Guide  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 3.  
Feature  
Software Security Features (continued)  
Description  
Control access to the  
system other than SSU:  
set user password  
To control access to using the system, set a user password and enable it  
through Setup or the SSU.  
To disable a password, change it to a blank entry or press CTRL-D in the  
Change Password menu of the User Password Option menu found in the  
Security Subsystem Group.  
To clear the password if you cannot access Setup or the SSU, change the Clear  
Password jumper (see Chapter 5).  
Boot without keyboard  
The system can boot with or without a keyboard. During POST, before the  
system completes the boot sequence, the BIOS automatically detects and tests  
the keyboard if it is present and displays a message. There is no entry in the  
SSU to enable or disable a keyboard.  
Specify the boot sequence The sequence that you specify on the menu in the SSU MultiBoot Group will  
determine the boot order. If secure mode is enabled (a user password is set),  
then you will be prompted for a password before the server fully boots. If secure  
mode is enabled and the “Secure Boot Mode” option is also enabled, the server  
will fully boot but will require a password before accepting any keyboard or  
mouse input.  
20  
Description  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 Upgrading  
Tools and Supplies Needed  
·
·
·
·
Phillips (cross head) screwdriver (#1 bit and #2 bit)  
Jumper removal tool or needle nosed pliers  
Pen or pencil  
Antistatic wrist strap and conductive foam pad (recommended)  
Warnings and Cautions  
These warnings and cautions apply throughout this chapter. Only a technically qualified person  
should configure the server board.  
WARNINGS  
System power on/off: The power button DOES NOT turn off the  
system AC power. To remove power from system, you must unplug the  
AC power cord from the wall outlet. Make sure the AC power cord is  
unplugged before you open the chassis, add, or remove any components.  
Hazardous conditions, devices & cables: Hazardous electrical  
conditions may be present on power, telephone, and communication  
cables. Turn off the server and disconnect the power cord,  
telecommunications systems, networks, and modems attached to the  
server before opening it. Otherwise, personal injury or equipment  
damage can result.  
CAUTIONS  
Electrostatic discharge (ESD) & ESD protection: ESD can damage  
disk drives, boards, and other parts. We recommend that you perform all  
procedures in this chapter only at an ESD workstation. If one is not  
available, provide some ESD protection by wearing an antistatic wrist strap  
attached to chassis ground¾any unpainted metal surface¾on your server  
when handling parts.  
ESD and handling boards: Always handle boards carefully. They can  
be extremely sensitive to ESD. Hold boards only by their edges. After  
removing a board from its protective wrapper or from the server, place the  
board component side up on a grounded, static free surface. Use a  
conductive foam pad if available but not the board wrapper. Do not slide  
board over any surface.  
Installing or removing jumpers: A jumper is a small plastic encased  
conductor that slips over two jumper pins. Some jumpers have a small tab on  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
top that you can grip with your fingertips or with a pair of fine needle nosed  
pliers. If your jumpers do not have such a tab, take care when using needle  
nosed pliers to remove or install a jumper; grip the narrow sides of the  
jumper with the pliers, never the wide sides. Gripping the wide sides can  
damage the contacts inside the jumper, causing intermittent problems with  
the function controlled by that jumper. Take care to grip with, but not  
squeeze, the pliers or other tool you use to remove a jumper, or you may  
bend or break the stake pins on the board.  
Server Board  
Installing the Server Board  
CAUTION  
The server board can be extremely sensitive to ESD and always requires  
careful handling. After removing it from the server, place it component side  
up on a nonconductive, static free surface to prevent shorting out the battery  
leads. If you place the board on a conductive surface, the battery leads may  
short out. If they do, this will result in a loss of CMOS data and will drain  
the battery. Do not slide the server board over any surface.  
1. Observe the safety and ESD precautions at the beginning of this chapter.  
2. Insert screws through the mounting holes and into the threaded standoffs. Make sure the board  
is properly seated, and then tighten all the screws firmly.  
3. Connect all internal cables to the server board.  
NOTE  
/
The floppy cable (Intel Part Number 738992-002) has been modified to  
support all floppy drives. The floppy drive connector on the cable (see  
connector label) is not keyed. Care should be taken to match pin 1 of the  
cable, indicated with a red stripe on the cable, with pin 1 of the floppy drive.  
4. Reinstall add-in boards.  
5. Connect all internal cables to add-in boards. Make sure you connect the power cables to the  
correct power connectors.  
6. Connect all peripheral device cables to the I/O panel on the rear of the server.  
7. Run the SSU to configure the server.  
22  
Upgrading  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 3. Server Board Screw Hole Locations  
Removing the Server Board  
CAUTION  
The server board can be extremely sensitive to ESD and always requires  
careful handling. After removing it from the server, place it component side  
up on a nonconductive, static free surface to prevent shorting out the battery  
leads. If you place the board on a conductive surface, the battery leads may  
short out. If they do, this will result in a loss of CMOS data and will drain  
the battery. Do not slide the server board over any surface.  
1. Observe the safety and ESD precautions at the beginning of this chapter.  
2. Open the server and remove peripherals and components blocking access to the server board.  
See your chassis manual for more information.  
3. Label and disconnect all internal cables connected to add-in boards.  
4. Remove all add-in boards.  
5. Label and disconnect all internal cables connected to the server board.  
6. Remove the server board retaining screws and set them aside.  
7. Remove the server board, and place it component side up on a nonconductive, static free  
surface or in an antistatic bag.  
8. If present, remove and save the EMI gasket that covers the I/O connectors on the board.  
L440GX+ Server Board Product Guide  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Memory  
Installing DIMMs  
CAUTIONS  
Use extreme care when installing a DIMM. Applying too much pressure can  
damage the socket. DIMMs are keyed and can be inserted in only one way.  
Mixing dissimilar metals may cause later memory failures resulting in data  
corruption. Only install DIMMs with gold-plated edge connectors in  
gold-plated sockets.  
See Chapter 1 for memory size and requirements.  
1. Observe the safety and ESD precautions at the beginning of this chapter.  
2. Open your server.  
3. Holding the DIMM only by its edges, remove it from its antistatic package.  
4. Orient the DIMM so that the two notches in the bottom edge of the DIMM align with the keyed  
socket.  
5. Insert the bottom edge of the DIMM into the socket, and press down firmly on the DIMM until  
it seats correctly.  
6. Gently push the plastic ejector levers on the socket ends to the upright position.  
7. Repeat the steps to install each DIMM.  
8. Close the server.  
9. Connect all external cables and the power cord to the server.  
10. Turn on the monitor and then the server.  
24  
Upgrading  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 4. Installing DIMMs  
Removing DIMMs  
CAUTION  
Use extreme care when removing a DIMM. Too much pressure can damage  
the socket slot. Apply only enough pressure on the plastic ejector levers to  
release the DIMM.  
1. Observe the safety and ESD precautions at the beginning of this chapter.  
2. Open the server.  
3. Gently push the plastic ejector levers out and down to eject a DIMM from its socket.  
4. Hold the DIMM only by its edges, being careful not to touch its components or gold edge  
connectors. Carefully lift it away from the socket, and store it in an antistatic package.  
5. Repeat to remove other DIMMs as necessary.  
6. Close the server.  
7. Connect all external cables and the power cord to the server.  
8. Turn on the monitor and then the server.  
L440GX+ Server Board Product Guide  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Processors  
WARNING  
If the server has been running, any installed processor and heat sink on  
the processor board(s) will be hot. To avoid the possibility of a burn, be  
careful when removing or installing server board components that are  
located near processors.  
CAUTIONS  
Processor must be appropriate: You may damage the server if you  
install a processor that is inappropriate for your server. Make sure your  
server can handle a newer, faster processor (thermal and power  
considerations). For exact information about processor interchangeability,  
contact your customer service representative or visit the Intel Customer  
Support website:  
http://support.intel.com/support/motherboards/server/l440gx  
Heat sink must be appropriate: Depending on your configuration, the  
existing processor may have a passive heat sink. If you REPLACE the  
processor with a faster one, it must have a fan heat sink (powered fan instead  
of a passive heat sink). If you ADD a second processor, it must have a fan  
heat sink. When adding a processor, you must leave the existing one in the  
primary connector (closest to the center of the server board).  
ESD and handling processors: Reduce the risk of electrostatic  
discharge (ESD) damage to the processor by doing the following: (1) Touch  
the metal chassis before touching the processor or server board. Keep part of  
your body in contact with the metal chassis to dissipate the static charge  
while handling the processor. (2) Avoid moving around unnecessarily.  
Removing a Processor  
1. Observe the safety and ESD precautions at the beginning of this chapter and the additional  
cautions given here. If the processor has a fan heat sink, disconnect the power wire from the  
slot on the server board.  
2. As you work, place boards and processors on a grounded, static free surface or conductive  
foam pad.  
3. Carefully pull back the tab of the retention mechanism (B in figure 5) with your left hand until  
the processor can be rotated out of the slot. With your right hand, grasp the processor on the  
side closest to the retention mechanism tab you are pulling back on, and rotate the one side of  
the processor out of the slot. Once that side is free, you can pull the other side out of the slot.  
26  
Upgrading  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAUTION  
This is a difficult process. Do not pull the tab of the retention mechanism  
back too far, as damage to either the retention mechanism or server board can  
occur. Pull the tab of the retention mechanism back just far enough for the  
retention lock to free the processor.  
4. Put the processor in a piece of conductive foam and store in an antistatic package.  
Figure 5. Installing a Processor  
A. Processor in Single Edge Contact cartridge  
B. Retention mechanism  
L440GX+ Server Board Product Guide  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing a Processor  
1. Observe the safety and ESD precautions at the beginning of this chapter and the additional  
cautions given here.  
2. If your server has one processor and you are ADDING a second, then you must remove the  
termination card from the secondary processor slot. Carefully pull back the tab of the retention  
mechanism with your left hand until the processor can be rotated out of the slot. With your  
right hand, grasp the processor on the side closest to the retention mechanism tab you are  
pulling back on, and rotate the one side of the processor out of the slot. Once that side is free,  
you can pull the other side out of the slot.  
CAUTION  
This is a difficult process. Do not pull the tab of the retention mechanism  
back too far, as damage to either the retention mechanism or server board can  
occur. Pull the tab of the retention mechanism back just far enough for the  
retention lock to free the processor.  
NOTE  
/
The processor Grounded Retention Mechanisms (GRM) are not compatible  
with SECC type processor packaging. The new GRMs only support SECC2  
type processors. If you plan on using SECC type processors, you must use  
the Universal Retention Mechanism (URM). URMs can be ordered through  
your distributor.  
Figure 6. Removing a Termination Board  
28  
Upgrading  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. If your server has one processor and you are REPLACING it, leave the termination board intact  
in the empty secondary slot. Remove the processor you want to replace. See “Removing a  
Processor” on page 26.  
4. If your server has two processors and you are REPLACING one or both, remove the  
appropriate one(s). See “Removing a Processor” on page 26.  
5. Remove the new processor from its antistatic package and place it on a grounded, static free  
surface or conductive foam pad.  
6. Orient the processor so that the heat sink faces the I/O connectors. Slide the processor into the  
retention mechanism. Push down firmly, with even pressure on both sides of the top, until the  
processor is seated.  
7. Attach the small end of the power cable to the fan connector on the S.E.C. cartridge, then attach  
the large end to the 3-pin connector on the server board.  
8. After you have installed the processor, you must configure its speed in BIOS set-up.  
L440GX+ Server Board Product Guide  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Replacing the Back up Battery  
The lithium battery on the server board powers the real time clock (RTC) for up to 10 years in the  
absence of power. When the battery starts to weaken, it loses voltage, and the server settings stored  
in CMOS RAM in the RTC (for example, the date and time) may be wrong. Contact your customer  
service representative or dealer for a list of approved devices.  
WARNING  
Danger of explosion if battery is incorrectly replaced. Replace only with  
the same or equivalent type recommended by the equipment  
manufacturer. Discard used batteries according to manufacturer’s  
instructions.  
ADVARSEL!  
Lithiumbatteri - Eksplosionsfare ved fejlagtig håndtering. Udskiftning  
må kun ske med batteri af samme fabrikat og type. Levér det brugte  
batteri tilbage til leverandøren.  
ADVARSEL  
Lithiumbatteri - Eksplosjonsfare. Ved utskifting benyttes kun batteri  
som anbefalt av apparatfabrikanten. Brukt batteri returneres  
apparatleverandøren.  
VARNING  
Explosionsfara vid felaktigt batteribyte. Använd samma batterityp eller  
en ekvivalent typ som rekommenderas av apparattillverkaren. Kassera  
använt batteri enligt fabrikantens instruktion.  
VAROITUS  
Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo  
ainoastaan laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty  
paristo valmistajan ohjeiden mukaisesti.  
30  
Upgrading  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 7. Replacing the Lithium Battery  
1. Observe the safety and ESD precautions at the beginning of this chapter.  
2. Open the chassis.  
3. Insert the tip of a small flat bladed screwdriver, or equivalent, under the tab in the plastic  
retainer.  
4. Gently push down on the screwdriver to lift the battery.  
5. Remove the battery from its socket.  
6. Dispose of the battery according to local ordinance.  
7. Remove the new lithium battery from its package, and, being careful to observe the correct  
polarity, insert it in the battery socket.  
8. Reinstall the plastic retainer on the lithium battery socket.  
9. Close the chassis.  
10. Run the SSU to restore the configuration settings to the RTC.  
L440GX+ Server Board Product Guide  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
32  
Upgrading  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 Configuration Software and Utilities  
This chapter describes the Power On Self Test (POST) and server configuration utilities. The table  
below briefly describes the utilities.  
Table 4.  
Utility  
Configuration Utilities  
Description and brief procedure  
Page  
BIOS Setup  
35  
If the system does not have a diskette drive, or the drive is disabled or  
misconfigured, use Setup to enable it.  
Or, you can move the CMOS jumper on the server board from the default  
setting (Protect CMOS memory) to the Clear setting; this will allow most server  
configurations to boot. For the procedure to do this, see the section “CMOS  
Jumper” in Chapter 5 in this manual. Then run the SSU to configure the  
server.  
50  
System Setup  
Utility (SSU)  
Use for extended system configuration of onboard resources and add-in  
boards, and for viewing the system event log, setting boot device priority, or  
setting system security options.  
The SSU may be run from either the Server Configuration CD or from a DOS-  
bootable diskette.  
Information entered via the SSU overrides information entered via BIOS  
Setup.  
EMP Console  
Use to access and monitor the server remotely.  
62  
75  
FRUSDR Load  
Utility  
Use to update the Field Replacement Unit (FRU), Sensor Data Record (SDR),  
and Desktop Management Interface (DMI) flash components.  
BIOS Update  
Utility  
Use to update the BIOS or recover from a corrupted BIOS update.  
79  
82  
83  
Firmware Update  
Utility  
Use to update BMC flash ROM.  
Using the Adaptec Use to configure or view the settings of the SCSI host adapters and onboard  
SCSI Utility  
SCSI devices in the server.  
Hot Keys  
Use the keyboard’s numeric pad to enter numbers and symbols.  
Table 5.  
Hot Keys  
To do this:  
Press these keys  
Clear memory and reload the operating  
<Ctrl+Alt+Del>  
system¾this is a system reset.  
Secure your system immediately.  
<Ctrl+Alt>+hotkey (Set your hot key combination with the  
SSU or Setup.)  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Power On Self Test (POST)  
Each time you turn on the system, POST starts running. POST checks the server board, processor,  
memory, keyboard, and most installed peripheral devices. During the memory test, POST displays  
the amount of memory that it is able to access and test. The length of time needed to test memory  
depends on the amount of memory installed. POST is stored in flash memory.  
1. Turn on your video monitor and server. After a few seconds POST begins to run.  
2. After the memory test, these screen prompts and messages appear:  
Press <F2> key if you want to run SETUP  
Keyboard.....Detected  
Mouse........Detected  
3. If you do not press <F2> and do NOT have a device with an operating system loaded, the  
above message remains for a few seconds while the boot process continues, and the system  
beeps once. Then this message appears:  
Operating system not found  
If you do not press <F2> and DO have an operating system loaded, the boot process continues,  
and this message appears:  
Press <Ctrl><A> to enter SCSI Utility  
4. Press <Ctrl+A> if there are SCSI devices installed. When the utility opens, follow the  
displayed instructions to configure the onboard SCSI host adapter settings and to run the  
SCSI utilities. Also see “Using the Adaptec SCSI Utility” on page 83. If you do not enter the  
SCSI utility, the boot process continues.  
5. Press <Esc> during POST to pop up a boot menu when POST finishes. From this menu you  
can choose the boot device or enter BIOS Setup.  
After POST completes, the system beeps once.  
What appears on the screen after this depends on whether you have an operating system loaded and  
if so, which one.  
If the system halts before POST completes running, it emits a beep code indicating a fatal system  
error that requires immediate attention. If POST can display a message on the video display screen,  
it causes the speaker to beep twice as the message appears.  
Note the screen display and write down the beep code you hear; this information is useful for your  
service representative. For a listing of beep codes and error messages that POST can generate, see  
the “Solving Problems” chapter in this manual.  
34  
Configuration Software and Utilities  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using BIOS Setup  
This section describes the BIOS Setup options. Use Setup to change the server configuration  
defaults. You can run Setup with or without an operating system being present. Setup stores most  
of the configuration values in battery backed CMOS; the rest of the values are stored in flash  
memory. The values take effect when you boot the server. POST uses these values to configure  
the hardware; if the values and the actual hardware do not agree, POST generates an error message.  
You must then run Setup to specify the correct configuration.  
Run Setup: You may run Setup to modify such server board feature as:  
·
·
·
·
·
·
·
·
Select diskette drive  
Select parallel port  
Select serial port  
Set time/date (to be stored in RTC)  
Configure IDE hard drive  
Specify boot device sequence  
Enable SCSI BIOS  
Specify processor speed  
Run SSU, not Setup: You must run the SSU instead of Setup to do the following:  
·
·
·
Add or remove any ISA board that is not Plug and Play-compatible  
Enter or change information about a board  
Alter server resources (such as interrupts, memory addresses, I/O assignments) to user selected  
choices instead of choices selected by the BIOS resource manager  
Record Your Setup Settings  
If the default values ever need to be restored (after a CMOS clear, for example), you must run  
Setup again. Referring to the worksheets could make your task easier.  
If You Cannot Access Setup  
If the diskette drive is misconfigured so that you cannot access it to run a utility from a diskette,  
you may need to clear CMOS memory. You will need to open the server, change a jumper setting,  
use Setup to check and set diskette drive options, and change the jumper back. For a step-by-step  
procedure, see Chapter 5, under the heading, “CMOS Jumper.”  
L440GX+ Server Board Product Guide  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Starting Setup  
You can enter and start Setup under several conditions:  
·
·
When you turn on the server, after POST completes the memory test  
When you reboot the server by pressing <Ctrl+Alt+Del> while at the DOS operating system  
prompt  
·
When you have moved the CMOS jumper on the server board to the “Clear CMOS” position  
(enabled); for the procedure, see Chapter 5, under the heading “CMOS Jumper”  
In the three conditions listed above, after rebooting, you will see this prompt:  
Press <F2> to enter SETUP  
In a fourth condition, when CMOS/NVRAM has been corrupted, you will see other prompts but not  
the <F2> prompt:  
Warning: cmos checksum invalid  
Warning: cmos time and date not set  
In this condition, the BIOS will load default values for CMOS and attempt to boot.  
Setup Menus  
To:  
Press  
Get general help  
<F1> or <Alt+H>  
Move between menus  
¬ ®  
Go to the previous item  
Go to the next Item  
¯
Change the value of an item  
Select an item or display a submenu  
Leave a submenu or exit Setup  
Reset to Setup defaults  
Save and exit Setup  
+ or -  
<Enter>  
<Esc>  
<F9>  
<F10>  
When you see this:  
What it means  
On screen, an option is shown but you You cannot change or configure the option in that menu screen.  
cannot select it or move to that field.  
Either the option is autoconfigured or autodetected, or you must  
use a different Setup screen, or you must use the SSU.  
On screen, the phrase Press Enter  
appears next to the option.  
Press <Enter> to display a submenu that is either a separate full  
screen menu or a popup menu with one or more choices.  
The rest of this section lists the features that display onscreen after you press <F2> to enter Setup.  
Not all of the option choices are described, because (1) a few are not user selectable but are  
displayed for your information, and (2) many of the choices are relatively self explanatory.  
36  
Configuration Software and Utilities  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Main Menu  
You can make the following selections on the Main Menu itself. Use the submenus for other  
selections.  
Feature  
Choices  
Description  
System Time  
System Date  
Legacy Diskette A:  
HH:MM:SS  
MM/DD/YYYY  
Sets the system time.  
Sets the system date.  
Selects the diskette type.  
Disabled  
360KB  
1.2 MB  
720KB  
1.44/1.25 MB  
2.88 MB  
Legacy Diskette B:  
Disabled  
360KB  
1.2 MB  
720KB  
1.44/1.25 MB  
2.88 MB  
Primary IDE Master  
Primary IDE Slave  
Secondary IDE Master  
Secondary IDE Slave  
Keyboard Features  
Processor Settings  
Language  
Enters submenu.  
Enters submenu.  
Enters submenu.  
Enters submenu.  
Enters submenu.  
Enters submenu.  
English (US)  
Français  
Español  
Selects which language BIOS displays.  
Deutsch  
Italiano  
L440GX+ Server Board Product Guide  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Primary/Secondary IDE Master and Slave Submenu  
Feature  
Choices  
Description  
Type  
Auto  
None  
CD-ROM  
IDE Removable  
Auto forces the server to attempt autodetection of the drive type.  
None informs the server to ignore this drive.  
CD ROM allows the manual entry of some fields described below.  
IDE Removable allows the manual entry of some fields described  
below.  
ATAPI Removable  
User  
ATAPI Removable allows the manual entry of some fields  
described below.  
User allows the manual entry of all fields described below.  
CHS Format  
Cylinders  
0 to 65535  
1 to 16  
0 to 63  
N/A  
Number of Cylinders on Drive.  
This field is changeable only for Type User.  
Heads  
Number of read/write heads on drive.  
This field is available only for Type User.  
Sectors  
Number of sectors per track.  
This field is available only for Type User.  
Maximum  
Capacity  
Computed size of drive from cylinders, heads, and sectors  
entered. This field is informational only.  
LBA Format  
Total Sectors  
N/A  
N/A  
This field is informational only.  
This field is informational only.  
Maximum  
Capacity  
Multi-Sector  
Transfer  
Disabled  
2, 4, 8, or 16  
sectors  
Determines the number of sectors per block for multi-sector  
transfers.  
This field is informational only for Type Auto.  
LBA Mode  
Control  
Disabled  
Enabled  
Enabling LBA causes logical block addressing to be used in place  
of cylinders, heads, and sectors.  
This field is informational only for Type Auto.  
32 Bit I/O  
Enabling allows 32 bit IDE data transfers.  
Disabled  
Enabled  
Transfer Mode  
Standard  
Fast PIO 1  
Selects the method for moving data to and from the drive.  
This field is informational only for Type Auto.  
Fast PIO 2  
Fast PIO 3  
Fast PIO 4  
FPIO 3 / DMA 1  
FPIO 4 / DMA 2  
Ultra DMA  
Mode  
Disabled  
Mode 0  
Mode 1  
Mode 2  
Selects the Ultra DMA mode used for moving data to/from  
the drive.  
38  
Configuration Software and Utilities  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Keyboard Submenu  
Feature  
Choices  
Description  
Num Lock  
Selects the power on state for Num Lock.  
On  
Off  
Key Click  
Disabled  
Enables or disables the audible key click.  
Enabled  
Keyboard auto-repeat rate  
30/sec  
26.7/sec  
21.8/sec  
18.5/sec  
13.3/sec  
10/sec  
6/sec  
Sets the numbers of time per second a key will repeat  
while it is held down.  
2/sec  
Keyboard auto-repeat delay  
1/4 sec  
1/2 sec  
3/4 sec  
1 sec  
Sets the delay before a key starts to repeat when it is  
held down.  
Processor Settings Submenu  
Feature  
Choices  
Description  
CPU Speed Setting  
Sets the speed for the installed processor(s).  
350 MHz  
400 MHz  
450 MHz  
500 MHz  
550 MHz  
600 MHz  
CAUTION  
Attempting to set this higher than the proper  
speed for the installed processor(s) may cause  
damage to the processor(s) or prevent the  
server from booting until a CMOS clear is  
preformed.  
CPU POST Speed Settings N/A  
This field is informational only.  
Processor Retest  
Yes  
No  
Yes tells BIOS to clear the historical processor status  
and retest all processors on the next boot. BIOS  
automatically resets to No in next boot.  
Memory Cache  
Enabled  
Enables processor cache.  
Disabled  
Processor 1 Stepping ID  
N/A  
This field is informational only.  
This field is informational only.  
This field is informational only.  
This field is informational only.  
Processor 1 L2 Cache Size N/A  
Processor 2 Stepping ID N/A  
Processor 2 L2 Cache Size N/A  
L440GX+ Server Board Product Guide  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Advanced Menu  
You can make the following selections on the Advanced Menu itself. Use the submenus for the  
three other selections that appear on the Advanced Menu.  
Feature  
Choices  
Description  
Installed OS  
Other  
Win95  
Select Win95 if you are booting a Plug and Play capable  
operating system.  
Reset Configuration Data  
No  
Yes  
Select Yes if you want to clear the server configuration  
data during next boot. System automatically resets to No  
in next boot.  
PCI Configuration  
Enters submenu.  
Enters submenu.  
Integrated Peripherals  
Configuration  
Advanced Chipset Control  
Enters submenu.  
Use Multiprocessor  
Specification  
1.1  
1.4  
Selects the version of multiprocessor specification to use.  
Some operating systems do not support version 1.4.  
Large Disk Access Mode  
CHS  
LBA  
Select CHS if your OS is DOS. A large disk has more than  
1024 cylinders, more than 16 heads, or more than 63  
tracks per sector.  
Delay on Option ROMs  
Forces a short delay at the end of each Option ROM scan.  
Disabled  
Enabled  
PCI Configuration Submenu  
The PCI Configuration Menu contains selections that access other submenus.  
PCI Device, Embedded SCSI Submenu  
Feature  
Choices  
Description  
Option ROM Scan  
Enabled  
Disabled  
Enables option ROM scan of the onboard SCSI chip.  
There are 2 SCSI channels that are controlled by the same  
option ROM.  
Enable Master  
Latency Timer  
Enabled  
Disabled  
Enabled selects the device as a PCI bus master.  
Default  
0020h  
0040h  
0060h  
0080h  
00A0h  
00C0h  
00E0h  
Minimum guaranteed time, in units of PCI bus clocks, that  
a device may be master on a PCI bus.  
CAUTION  
Do not change this setting unless you fully  
understand the priority of this device on the  
PCI bus.  
40  
Configuration Software and Utilities  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PCI Device, Slot 1 - Slot 6 Submenus  
Feature  
Choices  
Description  
Enable Master  
Enabled  
Enables selected device as a PCI bus master.  
Disabled  
Latency Timer  
Default  
020h  
040h  
060h  
080h  
0A0h  
0C0h  
0E0h  
Minimum guaranteed time, in units of PCI bus clocks, that  
a device may be master on a PCI bus.  
CAUTION  
Do not change this setting unless you fully  
understand the priority of this device on the  
PCI bus.  
Integrated Peripheral Configuration Submenu  
Feature  
Choices  
Description  
COM1  
Disabled  
Enabled  
Auto  
Auto forces BIOS to configure the port.  
OS Controlled  
OS Controlled Forces the OS to configure the port.  
Base I/O Address  
Selects the base I/O address for COM 1.  
3F8  
2F8  
3E8  
2E8  
Interrupt  
COM2  
Selects the IRQ for COM1.  
IRQ 3  
IRQ 4  
Disabled  
Enabled  
Auto  
Auto forces BIOS to configure the port.  
PnP OS forces OS configures the port.  
PnP OS  
Base I/O Address  
Selects the base I/O address for COM2.  
3F8  
2F8  
3E8  
2E8  
Interrupt  
Selects the IRQ for COM2.  
IRQ 3  
IRQ 4  
Parallel Port  
Disabled  
Enabled  
Auto  
Auto forces BIOS to configure the port.  
PnP OS forces OS configures the port.  
PnP OS  
Mode  
Output only  
Bi-directional  
EPP  
Selects parallel port mode.  
ECP  
Base I/O Address  
378  
Selects the base I/O address for LPT port.  
278  
continued  
L440GX+ Server Board Product Guide  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Integrated Peripheral Configuration Submenu (continued)  
Feature  
Choices  
Description  
Interrupt  
Selects the IRQ for LPT port.  
IRQ 5  
IRQ 7  
DMA channel  
Selects the DMA for LPT port (only used for ECP mode).  
Enables onboard diskette controller.  
DMA 1  
DMA 3  
Floppy disk controller  
Disabled  
Enabled  
Advanced Chipset Control  
Feature  
Choices  
Description  
640-768K Memory  
Region  
Enabled  
Disabled  
Enabled forwards ISA Master and DMA cycles to the PCI  
bus. Disabled forwards these cycles to memory.  
Delayed Transaction  
Enabled  
Disabled  
Enables the delayed transaction mechanism when the  
PIIX4e is the target of a PCI transaction.  
Passive Release  
Enabled  
Disabled  
Enables the passive release mechanism on the PHOLD#  
signal when the PIIX4 is a PCI Master.  
42  
Configuration Software and Utilities  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Security Menu  
You can make the following selections on the Security Menu itself. Enabling the Supervisor  
Password field requires a password for entering Setup. The passwords are not case-sensitive.  
Feature  
Choices  
Description  
User Password is  
Clear  
Set  
Status only; user cannot modify. Once set, this can be disabled  
by setting it to a null string, or by clearing password jumper on  
server board.  
Supervisor Password is  
Set User Password  
Status only; user cannot modify.  
Clear  
Set  
Press Enter When the <Enter> key is pressed, you are prompted for a  
password; press ESC key to abort. Once set, this can be cleared  
by setting it to a null string, or by clearing password jumper on  
server board (see Server Board Jumpers in Chapter 5).  
Set Supervisor  
Password  
Press Enter When the <Enter> key is pressed, you are prompted for a  
password; press ESC key to abort. Once set, this can be cleared  
by setting it to a null string, or by clearing password jumper on  
server board (see Server Board Jumpers in Chapter 5).  
Password on Boot  
Disabled  
Enabled  
Requires password entry before boot. System will remain in  
secure mode until password is entered. Password on Boot takes  
precedence over Secure Mode Boot.  
Fixed Disk Boot Sector  
Secure Mode Timer  
Normal  
Write  
Protect  
Write protects boot sector on hard disk to protect against viruses.  
Disabled  
1 min  
2 min  
5 min  
10 min  
20 min  
1 hr  
Period of key/PS/2 mouse inactivity specified for secure mode to  
activate. A password is required for secure mode to function.  
Cannot be enabled unless at least one password is enabled.  
2 hr  
Secure Mode Hot Key  
(Ctrl-Alt- )  
[ ]  
Key assigned to start the Quicklock feature. Cannot be enabled  
[A, B, ..., Z] unless at least one password is enabled.  
Secure Mode Boot  
Disabled  
System will boot in secure mode. You must enter a password to  
Enabled  
unlock the system. Cannot be enabled unless at least one  
password is enabled.  
Video Blanking  
Disabled  
Enabled  
Blank video when secure mode is activated. You must enter a  
password to unlock the system. Cannot be enabled unless at  
least one password is enabled.  
Floppy Write Protect  
Front Panel Lockout  
Disabled  
Enabled  
When secure mode is activated, the diskette drive is write  
protected. You must enter a password to disable. Cannot be  
enabled unless at least one password is enabled.  
Disabled  
Enabled  
When secure mode is activated, the reset and power switches are  
locked. You must enter a password to unlock the system.  
Cannot be enabled unless at least one password is enabled.  
L440GX+ Server Board Product Guide  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Server Menu  
You can make the following selections on the Server Menu itself.  
Feature  
Choices  
Description  
System Management  
Console Redirection  
PEP Management  
Enable Sleep Button  
Enters submenu.  
Enters submenu.  
Enters submenu.  
Disabled  
Enabled  
PCI IRQs to IO-APIC  
mappings  
Disabled  
Enabled  
Enabled - BIOS can describe all 24 IO APIC pins in the  
MP table for PCI interrupts. Not all MP operating  
systems and drivers can understand this description of  
the interrupts in the MP table.  
Disabled - BIOS will only use 16 IO APIC pins in the MP  
table for PCI interrupts. All PCI interrupts are routed to a  
standard ISA IRQ pins on IO APIC. All operating  
systems will work with standard ISA IRQ entries.  
Processor Retest  
Yes  
No  
Yes tells BIOS to clear the historical processor status  
and retest all processors on the next boot. BIOS  
automatically resets to No in next boot.  
Assert NMI on PERR  
Assert NMI on SERR  
Disabled  
Enabled  
Enabled generates an NMI on a parity error (PERR). To  
activate this feature, the system error (SERR) option  
must be enabled.  
Enabled generates an NMI on SERR.  
Disabled  
Enabled  
System Management Submenu  
Feature  
Choices  
Description  
Server Management  
Info  
Enters submenu.  
System Event  
Logging  
Disabled  
Enabled  
When enabled, system events will be logged by BIOS  
and BMC in system event log.  
Clear Event Log  
No  
Yes  
Yes clears the system event log (SEL) in BMC. BIOS  
automatically resets to NO for next boot.  
EMP Password switch Disabled  
Sets the EMP password.  
Enabled  
EMP Password  
[A..Z, 0..9]  
This field only shows up when the EMP password switch  
is enabled. Entering a password and pressing return will  
send the password immediately to the BMC. If a beep is  
heard the password was not accepted. If no password is  
entered, anyone has access to the server through the  
EMP Console.  
EMP Escape  
sequence  
+++  
Sets the escape sequence for the modem being used for  
EMP. This will force the modem to command mode.  
This is only used if the EMP direct connect/modem mode  
is set to modem.  
continued  
44  
Configuration Software and Utilities  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Management Submenu (continued)  
Feature  
Choices  
ATH  
Description  
EMP Hangup Line  
String  
Sets the Hangup Line Sequence for the modem being  
used for EMP. Used in EMP modem mode.  
Modem Init String  
AT&F0S0=1S14=0&D  
Sets the initialization string for the modem being used for  
EMP. Used in EMP modem mode.  
This field is only 16 characters long. The High Modem  
Init String field is a continuation of the Modem Init string  
so you can enter in another 4 characters.  
High Modem Init  
String  
0
This is a continuation of the Modem Init String. When 16  
characters are typed into the Modem Init String field, this  
field will appear to allow another 4 characters to be  
typed in.  
EMP Access Mode  
Pre-boot Only  
Always Active  
Disabled  
Pre-boot Only - EMP is only enabled during power down  
through end of POST. COM2 is returned to system use  
at the end of Post when operating system boots.  
Always Active - EMP is always enabled. COM2 cannot  
be used by operating system. It is now dedicated for  
EMP use.  
Disabled – EMP is disabled. COM2 is always available  
for system use by console redirection or operating  
system.  
EMP Restricted  
Mode Access  
Disabled  
Enabled  
If set to Enabled, Power on/off and Reset server controls  
via EMP are no longer available.  
EMP Direct  
Connect/Modem  
Mode  
Direct Connect  
Sets how EMP connects to the server. Direct Connect  
means a null modem serial cable directly connects  
COM2 connector port to the EMP console machine.  
Modem Mode  
Modem mode indicates that a modem is connected on  
COM2 for EMP use.  
Server Management Information Submenu  
Items on this menu are set when the server board is manufactured and cannot normally be changed.  
The last two items refer to the firmware level of the BMC on the server board and HSC (Hot Swap  
Controller) from the Astor II server chassis. If circumstances require a change in the L440GX+  
server board’s firmware, specific direction will be provided by Intel Customer Support.  
Feature  
Choices  
N/A  
Description  
Board Part Number  
Board Serial Number  
System Part Number  
System Serial Number  
Chassis Part Number  
Chassis Serial Number  
BMC Revision  
Information field only  
Information field only  
Information field only  
Information field only  
Information field only  
Information field only  
Information field only  
Information field only  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
Primary HSB Revision  
N/A  
L440GX+ Server Board Product Guide  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Console Redirection Submenu  
Feature  
Choices  
Description  
COM Port Address  
When enabled, console redirection uses the I/O port specified.  
3F8 - typically is COM1  
Disabled  
3F8  
2F8  
2F8 - typically is COM2  
3E8  
All keyboard/mouse and video will be directed to this port. This  
is designed to be used only under DOS in text mode.  
IRQ #  
N/A  
This field is informational only.  
Baud Rate  
9600  
When console redirection is enabled, specifies the baud rate to  
be used.  
19.2k  
38.4k  
115.2k  
Flow Control  
No Flow Control None disallows flow control.  
CTS/RTS  
CTS/RTS is hardware-flow control.  
XON/XOFF  
CTS/RTS + CD  
XON/XOFF is software-flow control.  
CTS/RTS +CD is hardware plus carrier-detect flow control.  
46  
Configuration Software and Utilities  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PEP Management Submenu  
Verify in BIOS Setup of your server board whether or not your system BIOS includes PEP. If not,  
when it becomes available, you can download it from the Intel Customer Support website:  
http://support.intel.com/support/motherboards/server/l440gx  
Feature  
Choices  
Description  
PEP Filter Events  
PEP Enable  
Enters submenu.  
Disable  
Enables Platform Event Paging.  
Enable  
PEP Blackout Period [0…9]  
PEP Page String  
Sets the amount of time between pages in minutes. Valid range is  
from 0 to 10.  
Sets the string used to page you. Generally this is the attention  
command for your modem, followed by the number of your paging  
service, followed by the message you want to appear on your  
pager, followed by a modem hangup command. Use commas for  
1second pauses.  
This field is only 16 characters long. The 16-31, 32-47, and 48-63  
fields are a continuation of the PEP Page String Field so you can  
enter in another 48 characters for 64 characters total.  
16-31  
32-47  
48-63  
This is a continuation of the PEP Page String Field. When 16  
characters are typed into the Modem Init String field, this field will  
appear to allow another 16 characters to be typed in.  
This is a continuation of the PEP Page String Field. When 16  
characters are typed into the Block #1 field, this field will appear to  
allow another 16 characters to be typed in.  
This is a continuation of the PEP Page String Field. When 16  
characters are typed into the Block #2 field, this field will appear to  
allow another 16 characters to be typed in.  
Send Test Page  
Press Enter To send a test page, select "Send Test Page Now" from the popup  
menu.  
Send Test  
Page Now  
L440GX+ Server Board Product Guide  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PEP Filter Submenu  
This submenu allows you to set which events or error conditions cause the system to page you.  
Feature  
Choices  
Description  
PEF Enable  
Disable  
Enable  
Enables the Platform Event Filtering. If this is enabled, and one of  
the events you enable below occurs, the server will page you using  
the Page String (NV) information.  
Temperature Sensor Disable  
Enable  
Voltage Sensor  
Fan Sensor  
Disable  
Enable  
Disable  
Enable  
Chassis Sensor  
Power Supply  
BIOS (SMI Handle)  
BIOS POST  
Disable  
Enable  
Disable  
Enable  
Disable  
Enable  
Disable  
Enable  
FRB Sensor  
Disable  
Enable  
Fatal NMI  
Disable  
Enable  
Watchdog Timer  
Reset  
Disable  
Enable  
System Restart  
Disable  
Enable  
Boot Menu  
You can make the following selections on the Boot Menu itself.  
Feature  
Choices  
Description  
Boot-time Diagnostic  
Screen  
Disabled  
Enabled  
Extended RAM Step  
Boot Device Priority  
Hard Drive  
Enters submenu.  
Enters submenu.  
Enters submenu.  
Enters submenu.  
Removable Devices  
48  
Configuration Software and Utilities  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Extended RAM Step  
Choice  
Description  
1 MB  
Tests extended memory once per MegaByte  
Tests extended memory once per KiloByte  
Tests all extended memory  
1 KB  
Every Location  
No Memory test  
No extended memory is tested  
Boot Device Priority  
Use the up or down arrow keys to select a device; then press the <+> or <-> keys to move the  
device higher or lower in the boot priority list.  
Boot Priority  
Device  
Description  
1.  
2.  
3.  
4.  
Removable Devices  
Hard Drive  
Attempts to boot from a removable media device.  
Attempts to boot from a hard drive device.  
Attempts to boot from an ATAPI CD-ROM drive.  
Attempts to boot from the local area network.  
ATAPI CD-ROM Drive  
LANDesk (R) Service Agent II  
Hard Drive  
For options on this menu, use the up or down arrow keys to select a device; then press the <+> or  
<-> keys to move the device higher or lower in the boot priority list.  
Option  
Description  
1. Hard Drive #1 (or actual drive string)  
IDE drives will have a suffix attached to the drive ID string.  
PM - hard drive on Primary Master Channel  
PS - hard drive on Primary Slave Channel  
SM - hard drive on Secondary Master Channel  
SS - hard drive on Secondary Slave Channel  
SCSI CD-ROMs will be displayed here because the onboard  
SCSI BIOS treats CD-ROMs as hard drives.  
SCSI ZIP or removable drives will also appear here.  
Removable IDE ZIP drives will only show up if the removable  
media is formatted as a hard drive.  
2. Other Bootable Device  
Covers all the boot devices that are not reported to the system  
BIOS through the BIOS boot specification mechanism. This  
includes all PCI cards that are not BIOS boot compliant (legacy)  
as well as ISA cards that are not PnP compliant. ISA legacy  
cards will boot first before non BIOS boot compliant PCI cards  
(in scan order from lowest slot to highest).  
L440GX+ Server Board Product Guide  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Removable Devices  
For options on this menu, use the up or down arrow keys to select a device, then press the <+> or  
<-> keys to move the device higher or lower in the boot priority list.  
Option  
Description  
1. Legacy Floppy Drive  
Refers to the onboard 3.5” floppy drive.  
Removable IDE media may also show up here if the removable  
media was formatted in floppy emulation.  
Exit Menu  
You can make the following selections on the Exit Menu. Select an option using the up or down  
arrow keys; then press <Enter> to execute the option. Pressing <Esc> does not exit this menu.  
You must select one of the items from the menu or menu bar to exit.  
Choices  
Description  
Exit Saving Changes  
Exit Discarding Changes  
Load Setup Defaults  
Load Custom Defaults  
Save Custom Defaults  
Discard Changes  
Save Changes  
Exits after writing all modified Setup item values to NVRAM.  
Exits leaving NVRAM unmodified.  
Loads values of all Setup items from previously saved custom defaults.  
Loads default values for all Setup items.  
Saves present Setup values to custom defaults.  
Reads previous values of all Setup items from NVRAM.  
Writes all Setup item values to NVRAM.  
Using the System Setup Utility  
The System Setup Utility (SSU) is on the L440GX+ Server Board Resource software CD shipped  
with the server board. The SSU provides a graphical user interface (GUI) over an extensible  
framework for server configuration. For the L440GX+ systems, the SSU framework supports the  
following functions and capabilities:  
·
assigns resources to baseboard devices and add-in cards prior to loading the operating  
system (OS)  
·
·
·
·
allows you to specify boot device order and system security options  
permits viewing and clearing of the system’s critical event log  
allows troubleshooting of the server when the OS is not operational  
provides a system level view of the server’s I/O devices  
50  
Configuration Software and Utilities  
Download from Www.Somanuals.com. All Manuals Search And Download.  
When to Run the System Setup Utility  
The SSU is a DOS-based utility that supports extended system configuration operations for onboard  
resources and add-in boards. You can also view the system event log and to set system boot and  
security options. Use the SSU when you need to  
·
·
·
·
·
add and remove boards affecting the assignment of resources (ports, memory, IRQs, DMA)  
modify the server’s boot device order or security settings  
change the server configuration settings  
save the server configuration  
view or clear the system event log  
If you install or remove an ISA add-in board, you must run the SSU to reconfigure the server.  
Running the SSU is optional for PCI and Plug and Play ISA add-in boards.  
The SSU is PCI aware, and it complies with the ISA Plug and Play specifications. The SSU works  
with any compliant configuration (.CFG) files supplied by the peripheral device manufacturer.  
The I/O baseboard comes with a .CFG file. The .CFG file describes the characteristics of the board  
and the system resources that it requires. The configuration registers on PCI and ISA Plug and Play  
add-in boards contain the same type of information that is in a .CFG file. Some ISA boards also  
come with a .CFG file.  
The SSU uses the information provided by .CFG files, configuration registers, FLASH, and the  
information that you enter, to specify a system configuration. The SSU writes the configuration  
information to flash memory.  
The SSU stores configuration values in FLASH memory. These values take effect when you boot  
the server. POST checks the values against the actual hardware configuration; if they do not agree,  
POST generates an error message. You must then run the SSU to specify the correct configuration  
before the server boots.  
The SSU always includes a checksum with the configuration data so the BIOS can detect any  
potential data corruption before the actual hardware configuration takes place.  
What You Need to Do  
The SSU may be run directly from the Server Resource CD by booting the server system to the CD  
and selecting “Utilities” or from a set of DOS diskettes.  
If you choose to run the SSU from a set of DOS diskettes, you must create the SSU diskettes from  
the Server Resource CD by booting to the CD and selecting “Create Diskettes.” Alternatively, if  
you have a Windows 95 or Windows NT workstation, you can insert the CD into that system and  
create diskettes from the “Utilities” menu of the graphical user interface.  
If your diskette drive is disabled, or improperly configured, you must use the flash resident Setup  
utility to enable it so that you can use the SSU. If necessary, you can disable the drive after you  
exit the SSU. Information entered using the SSU overrides any entered using Setup.  
L440GX+ Server Board Product Guide  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Running the SSU  
·
Running the SSU Locally  
Running the ssu.bat file provided on the SSU media starts the SSU. If the server boots directly  
from the SSU media, the ssu.bat file is automatically run. If it boots from a different media, the  
SSU can be started manually or by another application. When the SSU starts in the local  
execution mode (the default mode), the SSU accepts input from the keyboard and/or mouse.  
The SSU presents a VGA based Graphical User Interface (GUI) on the primary monitor.  
The SSU runs from writable, nonwritable, removable, and nonremovable media. If the SSU is  
run from nonwritable media, user preference settings (such as screen colors) can not be saved.  
The SSU supports the ROM-DOS V6.22 operating system. It may run on other ROM-DOS-  
compatible operating systems but they are not supported. The SSU will not operate from a  
“DOS box” running under an operating system such as Windows.  
·
Running the SSU Remotely  
Running the SSU remotely requires a remote server with a LANDesk Server Monitor Module 2  
(SMM2) card and a local system with Remote Control software available.  
The SMM2 card provides video memory, keyboard, and mouse redirection support for the  
remote server. The Remote Control console of the local system displays and sends video  
memory and user input to the remote server through either a modem or an Ethernet link.  
Because the SSU runs exclusively on the remote server, any files required for the SSU to run  
must be available on the remote server (on removable or nonremovable media).  
If you connect the local system to the remote server through a network or modem you can see  
the console, control the mouse, and control the keyboard of the remote server.  
Starting the SSU  
SSU consists of a collection of task oriented modules plugged into a common framework called the  
Application Framework (AF). The Application Framework provides a launching point for  
individual tasks and a location for setting customization information. For full functionality the SSU  
requires the availability of the AF.INI, AF.HLP, plus any .ADN files and their associated .HLP and  
.INI files.  
1. Turn on your video monitor and your system.  
2. There are two ways to start the SSU.  
a. After creating set of three SSU diskettes from the CD: Insert the first SSU diskette in  
drive A, and press the reset button or <Ctrl+Alt+Del> to reboot your server from the  
diskette.  
b. Directly from the Server Resource CD: Insert the Server Resource CD into your  
CD ROM drive and press the reset button or <Ctrl-Alt-Del> to reboot. When prompted to  
do so, press <F2> to enter BIOS Setup. From the Boot Menu, select the Boot Device  
Priority option and then select CD-ROM as your primary boot device. Save those settings  
and exit BIOS Setup. The server will boot from the CD-ROM and display a menu of  
options. Follow the instructions in the menu to start the SSU.  
3. When the SSU title appears on the screen, press <Enter> to continue.  
4. The mouse driver loads if it is available; press <Enter> to continue.  
52  
Configuration Software and Utilities  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. This message appears:  
Please wait while the Application Framework loads....  
6. When the main window of the SSU appears, you can customize the user interface before  
continuing.  
Figure 8. System Setup Utility Main Window  
L440GX+ Server Board Product Guide  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Customizing the SSU  
The SSU lets you customize the user interface according to your preferences. The AF sets these  
preferences and saves them in the AF.INI file so that they take effect the next time you start the  
SSU. There are four user customizable settings:  
·
Color - this button lets you change the default colors associated with different items on the  
screen with predefined color combinations. The color changes are instantaneous.  
Mode - this button lets you set the desired expertise level.  
·
¾ novice  
¾ intermediate  
¾ expert  
The expertise level determines which tasks are visible in the Available Tasks section and what  
actions each task performs. For a new mode setting to take effect, you must exit the SSU and  
restart it.  
·
·
Language - this button lets you change the strings in the SSU to strings of the appropriate  
language. For a new language setting to take effect, you must exit the SSU and restart it.  
Other - this button lets you change other miscellaneous options in the SSU. The changes take  
effect immediately.  
To change the interface default values:  
Use the mouse to click on the proper button in the Preferences section of the SSU Main  
window.  
or  
Use the tab and arrow keys to highlight the desired button, and press the spacebar or <Enter>.  
or  
Access the menu bar with the mouse or hot keys (Alt + underlined letter).  
NOTE  
/
If you run the SSU from nonwritable media (like a CD-ROM), these  
preferences will be lost when you exit the SSU.  
Launching a Task  
It is possible to have many tasks open at the same time, although some tasks may require complete  
control to avoid possible conflicts. The tasks achieve complete control by keeping the task as the  
center of operation until you close the task window.  
To launch a task:  
In the SSU Main window, double click on the task name under Available Tasks to display the  
main window for the selected task.  
or  
Highlight the task name, and click on OK.  
or  
Use the tab and arrow keys to highlight the desired button, and press the spacebar or <Enter>.  
54  
Configuration Software and Utilities  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Resource Configuration Add-in (RCA) Window  
The RCA provides three major functions:  
·
·
·
Creates representations of devices that cannot be discovered by the system (ISA cards)  
Modifies the contents of the system by adding and removing devices  
Modifies the resources used by devices  
You can use the RCA window to define an ISA card or add an ISA card by clicking on the  
appropriate button. Removing an ISA card requires that the card be highlighted in the Devices  
section of the screen before clicking on the button. You can only add as many ISA cards as you  
have ISA slots available.  
1. From the SSU main window, launch the RCA by selecting the “Resources” task under the RCA  
heading in the task box.  
2. When the RCA window appears, it displays messages similar to the following:  
Baseboard: Server board Server board  
PCI Card: Bus 00 dev 00 -– Host Processor Bridge  
PCI Card: Bus 00 dev 0D –- Multifunction Controller  
PCI Card: Bus 00 dev 0F –- Ethernet Controller  
PCI Card: Bus 00 dev 12 –- Multifunction Controller  
PCI Card: Bus 00 dev 14 –- VGA Controller  
3. To configure a device, select its name in the Devices section of the RCA window, and press the  
spacebar or <Enter>, or click on it.  
4. It is possible to close the RCA window and return to the AF by clicking on the Close button.  
Any changes made will be kept in memory for use by the RCA when it is rerun.  
5. Save all the changes made by clicking on the Save button. Saving writes your current  
configuration to nonvolatile storage where it will be available to the system after every reboot.  
6. Closing the window by clicking on the system menu, the dash in the upper left corner, discards  
all changes.  
Defining an ISA Card  
An ISA card usually comes with a vendor created .CFG file that specifies the resources the card  
requires to function properly. If the .CFG file is unavailable, you must manually create it or define  
the card through the SSU. Defining an ISA card consists of specifying the name of the card and the  
resources it consumes. This allows the RCA to consider the ISA card resource requirements when  
the RCA tries to resolve conflicts. The information is also used by the system BIOS to configure  
the hardware when the system is booted.  
1. To add or remove ISA card resources, click on the appropriate resource buttons, select the  
desired value, and click on Add or Remove.  
2. After you complete the necessary information, click on Save.  
3. To edit a card, click on Load to retrieve the card information. After making changes, click  
on Save.  
4. To create a card, click on New.  
5. To remove a current definition of a card, click on Delete.  
L440GX+ Server Board Product Guide  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Adding and Removing ISA Cards  
Adding and removing cards through the RCA provides a way for the RCA to run its conflict  
detection algorithms on the resources requested by the cards. This alerts you to any possible  
problems with that particular card in the current configuration.  
·
To add an ISA card:  
1. Click on Add ISA Card in the RCA window.  
2. Specify the directory for the .CFG file.  
3. Select the file and click on Ok.  
·
To remove an ISA card:  
1. Select a valid ISA card in the Devices section of the RCA window.  
2. Click on Remove ISA Card.  
Modifying Resources  
Modifying the resources of a device may be necessary to accommodate certain operating systems,  
applications, and drivers. It may also be necessary to modify resources to resolve a conflict.  
·
To modify the resources associated with a device:  
1. Highlight the device in the Devices section of the RCA window.  
2. Press the spacebar or <Enter>, or double click on the entry.  
This displays the functions of the selected device along with possible choices and the resources  
associated with those choices.  
·
To make a modification:  
1. Highlight the function in the Configuration window.  
2. Press the spacebar or <Enter>, or double click on the entry (this updates the Choice and  
resource lists).  
3. Press the tab key to get to the Choice list, and press <Enter>.  
4. Use the arrow keys to select a proper choice, and press <Enter> again.  
5. If the choice allows multiple possible values for a particular resource, use the hot key to  
select a resource, and press the spacebar or double click on the resource.  
6. Select the desired resource, and click on Ok.  
System Resource Usage  
Clicking on the Resource Use button in the Configuration window displays the System Resource  
Usage window. This window shows what resources each device is consuming. This information is  
useful for choosing resources if a conflict occurs. Devices can be organized according to the  
resources you want to examine using the options in the Resource section of the screen. The  
resource information can also be written to a plain text file through this window.  
Multiboot Options Add-in  
Under this window you can change the boot priority of a device.  
1. Select a device.  
2. Press the + button to move it up in the list. Press the - button to move it down.  
56  
Configuration Software and Utilities  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Security Add-in  
Under this window, you can set the User and Administrator passwords, and security options.  
To Set the User Password  
1. Click on the user password button.  
2. Enter the password in the first field.  
3. Confirm the password by entering it again in the second field.  
To Change or Clear the User Password  
1. Click on the User password button.  
2. Enter the old password in the first field.  
3. Enter the new password in the second field (or leave blank to clear).  
4. Confirm the password by entering it again in the second field (or leave blank to clear).  
To Set the Administrator Password  
1. Click on the Administrator password button.  
2. Enter the password in the first field.  
3. Confirm the password by entering it again in the second field.  
To Change or Clear the Administrator Password  
1. Click on the Administrator password button.  
2. Enter the old password in the first field.  
3. Enter the new password in the second field (or leave blank to clear).  
4. Confirm the password by entering it again in the second field (or leave blank to clear).  
Security Options  
Under this window, you can set the other security options:  
·
·
Hot Key - Set a key sequence that, when pressed, will drop the server into secure mode.  
Lock-Out Timer - Set an interval that, if no activity takes place during it, will drop the server  
into secure mode.  
·
·
·
·
Secure Boot Mode - Force the server to boot directly into secure mode.  
Video Blanking - Turn off the video when the server is in secure mode.  
Floppy Write - Control access to the diskette drive while the server is in secure mode.  
Reset/Power Switch Locking - Control the power and reset buttons while the server is in  
secure mode.  
L440GX+ Server Board Product Guide  
57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SEL Manager Add-in  
Clicking on the SEL Manager Add-in task brings up the Server Event Log (SEL) viewer. You can  
load and view the current SEL data stored in the BMC, save the currently loaded SEL data to a file,  
view previously saved SEL data, or clear the SEL. The SEL Viewer has the following menus:  
File  
The File menu has the following options:  
·
·
·
·
Load SEL… View data from a previously saved SEL file.  
Save SEL… Save the currently loaded SEL data to a file.  
Clear SEL Clears the SEL data from the BMC.  
Exit Quits the SEL Viewer.  
View  
The View menu has the following options:  
·
·
·
SEL Info Displays information about the SEL. These fields are display only.  
All Events Displays the current SEL data from the BMC.  
By Sensor Brings up a pop-up menu that allows you to view only the data from a certain  
sensor type.  
·
By Event Brings up a pop-up menu that allows you to view only the data from a certain  
event type.  
Settings  
The Settings menu has the following options:  
·
Display HEX/Verbose Toggles between the Hex/interpreted mode of displaying the SEL  
records.  
·
Output Text/Binary Determines whether SEL data will be saved to the file (as under  
File - Save) in binary format or verbose format.  
Help  
The Help menu has the following option:  
About Displays the SEL Viewer version information.  
·
58  
Configuration Software and Utilities  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FRU Manager Add-in  
Clicking on the FRU Manager Add-in task brings up the Field Replaceable Unit (FRU) viewer.  
You can load and view the current FRU data stored in the BMC, save the currently loaded FRU  
data to a file, view previously saved FRU data. The FRU Viewer has the following menus:  
File  
The File menu has the following options:  
·
·
·
·
Load… View data from a previously saved FRU file.  
Save… Saves the currently loaded FRU data to a file.  
Save As… Saves the currently loaded FRU data to a file.  
Exit Quits the FRU Viewer.  
View  
The View menu has the following options:  
·
·
·
FRU Info Displays information about the FRU. These fields are display only.  
All FRU Areas Displays the current FRU data from the BMC.  
By Device Type Brings up a pop-up menu that allows you to view only the data from a certain  
device type.  
Settings  
The Settings menu has the following options:  
·
Display HEX/Verbose Toggles between the Hex/interpreted mode of displaying the  
FRU records.  
·
Output Text/Binary Determines whether FRU data will be saved to the file (as under  
File - Save) in binary format or verbose format.  
Help  
The Help menu has the following option:  
About Displays the FRU Viewer version information.  
·
L440GX+ Server Board Product Guide  
59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SDR Manager Add-in  
Clicking on the SDR Manager Add-in task brings up the Sensor Data Record (SDR) viewer. You  
can load and view the current SDR data stored in the BMC, save the currently loaded SDR data to a  
file, view previously saved SDR data. The SDR Viewer has the following menus:  
File  
The File menu has the following options:  
·
·
·
·
Load… View data from a previously saved SDR file.  
Save… Saves the currently loaded SDR data to a file.  
Save As… Saves the currently loaded SDR data to a file.  
Exit Quits the SDR Viewer.  
View  
The View menu has the following options:  
·
·
·
SDR Info Displays information about the SDR. These fields are display only.  
All Records Displays the current SDR data from the BMC.  
By Record Type Brings up a pop-up menu that allows you to view only the data from a  
certain record type.  
Settings  
The Settings menu has the following options:  
·
Display HEX/Verbose Toggles between the Hex/interpreted mode of displaying the SDR  
records.  
·
Output Text/Binary Determines whether SDR data will be saved to the file (as under  
File - Save) in binary format or verbose format.  
Help  
The Help menu has the following option:  
About Displays the SDR Viewer version information.  
·
Exiting the SSU  
Exiting the SSU causes all windows to close.  
1. Exit the SSU by opening the menu bar item File in the SSU Main window.  
2. Click on Exit.  
or  
Highlight Exit, and press <Enter>.  
60  
Configuration Software and Utilities  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Platform Event Paging  
With Platform Event Paging (PEP), your server can be configured to automatically dial up a paging  
service and page you when a server management related event occurs. Platform events include  
temperature out-of-range, voltage out-of-range, chassis intrusion, and fan failure.  
If PEP is enabled and the BMC receives or detects a new event, it automatically sends a page. It  
can send a page if the processors are down or if the system software is unavailable.  
PEP needs an external modem connected to the server's EMP (Emergency Management Port) serial  
connection. This is typically the COM2 serial connector.  
Verify in BIOS Setup of your server board whether or not your system BIOS includes PEP. If not  
you can download it from the Intel Customer Support website when it becomes available.  
http://support.intel.com/support/motherboards/server/l440gx  
Using Platform Event Paging  
1. Enter Setup.  
2. Enter the PEP Management submenu from the Server Menu.  
3. Set the PEP Enable field to Enable.  
4. Enter your page string in the PEP Page String field. This consists of the attention command for  
you modem (generally ATDT), the number of your paging service, several commas (each  
comma is a 1 second pause), the number/message you wish to appear on your pager, and the  
hangup command for your modem (generally ATH). You will need to experiment with the  
timing to ensure you are paged properly. Set the Send Test Page field to Send Test Page Now  
to generate a test page.  
5. If you wish to filter events so that only certain events will originate a page, enter the PEP Filter  
submenu.  
a. Set the PEF Enable field to Enable.  
b. Enable all of the events about which you want to be paged.  
c. Escape out of the PEP Filter submenu.  
6. Set the time between pages with the Page Blackout Field. If you want to be paged every five  
minutes, set it to 5. The range is from 0 to 10 minutes.  
7. Exit BIOS Setup.  
L440GX+ Server Board Product Guide  
61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Emergency Management Port Console  
The Emergency Management Port (EMP) Console is a software application designed to run on a  
Windows 95 or Windows NT 4.0 workstation and provides a server administrator’s interface to the  
Emergency Management Port (EMP) of the L440GX+ server. This interface allows remote server  
management via a modem or direct connection.  
The server control operations available with EMP Console are:  
·
·
·
Connecting to remote servers  
Powering the server on or off  
Resetting the server  
The EMP Console uses three management plug-ins to monitor the server:  
·
·
·
SEL Viewer  
SDR Viewer  
FRU Viewer  
The EMP Console also has Phonebook plug-in that can be used to create and maintain a list of  
servers and their phone numbers.  
The EMP Console software utility is on the L440GX+ resource CD that ships with the product. It  
can be installed directly from the CD onto a workstation or from diskettes that can be created by  
booting to the ROM-DOS operating system, also on the CD, and selecting Create Diskettes.  
62  
Configuration Software and Utilities  
Download from Www.Somanuals.com. All Manuals Search And Download.  
How EMP Console Works  
The EMP shares use of the COM2 port with the system on the server. When the EMP has control  
of the port, the port operates in command mode. When the system has control, the port operates in  
console redirect mode. When connecting to a server, the EMP Console checks to determine the  
mode of the COM2 port. The following discussion covers how EMP Console functions in  
each mode:  
·
Command mode is the default COM2 state. In this state, EMP Console communicates with the  
server's firmware, allowing the client to remotely reset or power the server up or down. The  
client can also view the server's System Event Log (SEL), Field Replaceable Unit (FRU)  
information, or Sensor Data Record (SDR) table.  
·
In console redirect mode, EMP Console serves as a PC ANSI terminal window for  
BIOS console redirection. Commands typed in this terminal window are transmitted through  
BIOS to the server's console, and text displayed on the server console is displayed on the  
EMP Console's terminal window. In this mode, you can remotely view boot messages, access  
BIOS setup, and run DOS text mode applications through the EMP Console’s terminal window.  
Figure 9. EMP Console in Command State  
L440GX+ Server Board Product Guide  
63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 10. EMP Console in Redirect State  
Figure 10 shows EMP Console window in redirect mode with the terminal window. The text that  
appears on the server monitor displays in the Redirect window.  
Availability of the various EMP Console features are determined by two factors: the BIOS  
EMP access mode and if the server's COM2 port is configured for console redirection. The three  
EMP access modes are disabled, pre-boot, and always active.  
Table 6.  
Mode  
EMP Console Access Modes (Server configured for console redirection)  
Server is powered off  
During BIOS POST  
After OS boots  
Disabled  
Redirect window  
Redirect window  
Redirect window appears,  
but is blank  
Pre-boot  
EMP commands available  
Redirect window*  
Redirect window*  
Redirect window  
Always Active EMP commands available  
EMP commands available  
* The operation mode can be modified by selections in the Reset and Power on/off dialogs. These are server control dialogs  
available in EMP Console.  
64  
Configuration Software and Utilities  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 7.  
Mode  
EMP Console Access Modes (Server not configured for console redirection)  
Server is powered off  
During BIOS POST  
After OS boots  
Disabled  
Redirect window appears,  
but is blank  
Redirect window appears,  
but is blank  
Redirect window appears,  
but is blank  
Pre-boot  
EMP commands available  
EMP commands available  
Redirect window appears,  
but is blank  
Always Active  
EMP commands available  
EMP commands available  
EMP commands available  
Requirements  
This section outlines the requirements and configurations necessary for using EMP Console.  
Operating Systems:  
·
Windows 95 or Windows 98  
¾ 16 MB of RAM, 32 MB recommended  
¾ 20 MB disk space  
Windows NT  
·
¾ Windows NT 4.0  
¾ 24 MB of RAM, 32 MB recommended  
¾ 20 MB disk space  
Client Configuration: EMP Console supports all COM ports on the client system, along with any  
Windows NT/95 compatible modem.  
Server Configuration: EMP Console requires the server's COM2 port to be connected to an  
external modem or directly connected to a serial cable.  
Direct Connect Configuration: A null modem serial cable is needed. Connect one end of the  
cable to the COM2 port of server and the other to a port on the client machine.  
Modem Configuration: On the client, EMP Console uses the Windows Application Program  
Interface (API) to determine if a modem is connected and available. The EMP Console does not  
configure the modem; it should be preconfigured through Windows.  
For modem support, the server must use a Hayes compatible modem that supports a baud rate of  
19.2k. The modem must be on the Windows 95 or NT Hardware Compatibility List provided by  
Microsoft. The server modem must be set in auto-answer mode for EMP Console to be able to  
connect to it.  
L440GX+ Server Board Product Guide  
65  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting up the Server for the EMP  
To use the EMP, you must configure the server's BIOS with specific settings. These settings are  
found in two submenus of the BIOS Server menu, the System Management Submenu and the  
Console Redirection submenu. The BIOS settings section, found earlier in this document, shows  
all the available options. This section focuses on the settings that must be configured in order to  
use the EMP.  
System Management Submenu  
All EMP related settings occur in the Server main menu. Change only the items below; all other  
default settings should remain the same.  
EMP Password Switch & EMP Password: Anytime an attempt to initiate a connection is made, a  
prompt for the user password appears. If no EMP password is setup, then anyone can access the  
EMP by clicking OK.  
In the EMP Password area of the Server menu, the EMP Password Switch option must be set to  
enable. Then type in a password of up to eight alphanumeric characters. If a beep is heard, the  
password was accepted.  
EMP Access Modes: Choose either Disabled, Pre-boot, or Always Active, depending on the type  
of EMP access needed. The tables above show what is available with a given setting.  
EMP Restricted Mode Access: Set Restricted Mode to either enabled or disabled as needed. If in  
enabled mode, this means that EMP Console's server control options, Power off and Reset, are  
unavailable, except power on. In disabled mode, these same server control options are available.  
EMP Direct Connect/Modem Mode: Select Direct Connect if a null modem serial cable directly  
connects the server's COM2 port to the EMP Console client machine. If they are connected via a  
modem, select Modem Mode.  
Console Redirection Submenu  
The settings in the Console Redirection Submenu of the Server menu must be set exactly as noted  
to be able to use the EMP.  
COM Port Address: Select 2F8. This is the COM2 port that must be used by the EMP. The  
IRQ# setting is automatically populated with the correct number based on the COM Port Address  
choice.  
Baud Rate: Select 19.2k.  
Flow Control: Choose CTS/RTS + CD.  
66  
Configuration Software and Utilities  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Main EMP Console Window  
The main EMP Console window provides a graphical user interface (GUI) to access server control  
operations and to launch the management plug-ins. At the top of the window is the menu and tool  
bar. These provide the options to initiate plug-ins and other support features. A status bar at the  
bottom displays connection information such as server name, line status, and mode.  
Toolbar  
The tool bar buttons of the EMP Console main window combine server control and management  
plug-in commands available from both the Connect and Action menus as follows:  
Displays the Connect dialog to allow connection to a selected server.  
Disconnects from the currently connected server.  
Displays the Power On/Off dialog.  
Displays the Reset dialog.  
Launches the SEL Viewer.  
Launches the SDR Viewer.  
Launches the FRU Viewer.  
Displays the Phonebook Dialog.  
Displays the online help.  
Status Bar  
The status bar is displayed at the bottom of the main window. It contains the following status  
information:  
·
·
·
SERVER NAME: The name of the connected server when connecting via modem.  
LINE: The type of line connection. This is either direct or modem.  
MODE: Either Redirect of EMP, depending on whether the EMP has control of the  
COM2 port.  
·
LINE STATUS: Gives status information about the server connection. For example, if a  
server is connected, the status bar says "Connected." Otherwise, the line is blank.  
L440GX+ Server Board Product Guide  
67  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EMP Console Main Menu  
·
File  
¾ Exit - exits EMP Console.  
Connect  
·
¾ Disconnect - disconnects the server connection.  
¾ [Re]Connect - displays the connect dialog.  
¾ A list of the five most recent modem connections. Click on one of these server names to  
initiate a connection.  
·
·
Action  
¾ Power On/Off - displays the Power on/off dialog.  
¾ Reset - displays the Reset dialog.  
¾ SEL Viewer - displays the SEL Viewer.  
¾ SDR Viewer - displays the SDR Viewer.  
¾ FRU Viewer - displays the FRU Viewer.  
¾ Phonebook - displays the Phonebook dialog.  
Help  
¾ Help Topics - help topics for EMP Console.  
¾ Help About - provides version information.  
Server Control Operations  
Three server control operations are available from the menu or toolbar in EMP Console: remote  
server connection, powering the server on and off, and resetting the server. The server console  
mode can also be switched between EMP active and BIOS redirect modes through post-power-up  
and reset options.  
68  
Configuration Software and Utilities  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connect  
When [Re]Connect is selected from the Connect menu, the Connect dialog in Figure 11 is  
displayed. This dialog allows you to connect to a server. If the client machine is already connected  
to a server, initiating connection generates a warning message. The message indicates that the  
existing connection will be terminated if you continue trying to initiate the new connection. You  
are prompted to enter the EMP password whenever a connection is attempted.  
Figure 11. Connect Dialog  
Options available in the dialog are:  
·
Line Selection - you can specify whether to use a direct connection or dial-up modem  
connection to the server.  
¾ Dial-up - connects to a selected server with a modem.  
¾ Direct connect (Serial Line) - connects to the selected server directly using a null modem  
serial cable.  
·
·
Server - a server name can be selected from the dropdown list of available servers. A server  
must be selected when the line selection is Dial-up.  
Serial Line - These options are enabled when the line selection is set to Direct connect  
(Serial Line).  
¾ Baud Rate - must be 19200 for EMP to connect properly.  
¾ COM Port No. - set the COM Port number to the port which the null modem serial cable is  
connected to.  
·
Connect - initiates the connection to the connected server. When this button is clicked, you are  
prompted for the EMP password.  
·
·
·
Config - displays the Phonebook dialog.  
Cancel - exits the Connect dialog without taking any action.  
Help - displays the help information for this dialog.  
L440GX+ Server Board Product Guide  
69  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Power On/Off  
Selecting Power On/Off from the Action menu displays the Power on/off dialog. This dialog  
provides commands to remotely power on or power off the server.  
Figure 12. Power On/Off Dialog  
Options available in the dialog are:  
·
·
Power ON - powers on the server.  
Power OFF - powers off the server. This option is not allowed if the server is configured in  
RESTRICTED mode for EMP operations.  
·
Post-power-up option - sets the mode selection of the server to EMP active or BIOS  
redirection. The setting is available after the next power-up. The default selection is  
EMP active.  
·
·
Cancel - exits the Connect dialog without taking any action.  
Help - displays the help information for this dialog.  
Reset  
Selecting Reset from the Action menu displays the Reset dialog. This dialog provides the ability to  
remotely reset the server with post-reset options.  
Figure 13. Reset Dialog  
70  
Configuration Software and Utilities  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Options available in the dialog are:  
·
System Reset - resets the server with the selected post-reset options. This operation is not  
allowed if the server is configured in RESTRICTED mode for EMP operations.  
Post-reset option - sets the post-reset option that will be in effect after reset. The options are  
EMP active or BIOS redirection. The default selection is EMP active.  
Cancel - exits the Connect dialog without taking any action.  
·
·
·
Help - displays the help information for this dialog.  
Phonebook  
EMP Console provides a support plug-in known as the Phonebook. The Phonebook stores names  
and numbers of servers in a list that can be updated by adding, modifying or deleting entries. The  
Phonebook can be opened from the main menu and toolbar, or launched from the Connect dialog  
by clicking the Config button.  
Figure 14. Phonebook Dialog  
Options available in the dialog are:  
·
·
·
Server - a dropdown list of server names stored in the Phonebook. If the New radio button is  
selected in the Operation area, this area is cleared.  
Phone No. - the number of the selected server. If the New radio button is selected in the  
Operation area, this area is cleared.  
Operation  
¾ New - lets you add a new entry in the Phonebook. Selecting this option clears the Server  
and Phone No. fields. You must click Save for the entry to be added to the Phonebook.  
¾ Modify - lets you edit an existing entry. You must select an existing entry from the Server  
dropdown list box and modify the existing phone number before selecting this option.  
Click Save in order to update the entry in the phonebook.  
¾ Delete - lets you delete an entry from the Phonebook. You must first select an existing  
server from the Server dropdown list box before selecting this option. You must click Save  
for the entry to be deleted.  
·
Save - saves a new or modified Phonebook entry, or deletes an entry if the Delete radio button  
is selected.  
L440GX+ Server Board Product Guide  
71  
Download from Www.Somanuals.com. All Manuals Search And Download.  
·
Connect - displays the Connect dialog with the server from the Phonebook's Server dropdown  
list box already populating the Connect dialog's Server field.  
·
·
Cancel - exits the Connect dialog without taking any action.  
Help - displays the help information for this dialog.  
Management Plug-ins  
SEL Viewer  
The SEL Viewer provides access to the System Event Log on the server and can display records in  
either hexadecimal or text (verbose) form. Options available through the SEL Viewer are:  
·
·
·
·
·
·
·
·
·
·
View the SEL from a saved file  
Save the SEL to a file  
View SEL summary info  
View all SEL entries  
View SEL entries by sensor type  
View SEL entries by event type  
Set SEL display mode to either Hex or verbose mode  
Set the SEL output file format to either text or binary format  
Close the SEL Viewer  
Exit the EMP Console  
SEL Viewer Menu Options  
The following menu options are found on the SEL Viewer menu bar:  
·
File  
¾ Open - views SEL data from a previously saved file if it was stored in binary format.  
Selecting the Open menu item allows you to specify a filename under which the data is  
found. If the file cannot be opened, the program displays an error message.  
¾ Close - closes the SEL Viewer.  
¾ Save - saves the SEL events to a file in either binary raw or verbose text format. The  
binary file may be retrieved later. Once data has been saved to a file, selecting this option  
will save the data to the previously saved file. If no SEL events have been retrieved, then  
this menu option is not available.  
¾ Save As - saves the SEL events to a new file in either binary raw or verbose text format.  
The binary file may be retrieved later. Selecting this option lets you specify a filename to  
which the data will be saved. If no SEL events have been retrieved, then this menu option  
is not available.  
¾ Exit - exits the EMP Console.  
View  
·
¾ SEL Information - displays SEL summary information as returned by the server.  
¾ All Events - displays all events in the SEL.  
¾ By Sensor Type - displays all events in the SEL generated by a specific sensor type such  
as voltage, temperature, etc. A submenu lets you select the sensor type to be displayed.  
72  
Configuration Software and Utilities  
Download from Www.Somanuals.com. All Manuals Search And Download.  
¾ By Event - displays all the events in the SEL of a particular event type; for example,  
threshold, digital, or discrete. A pop-up menu lets you select the event type to be  
displayed.  
¾ Settings - changes several operating parameters for the SEL Viewer. This menu displays  
the following suboptions:  
·
·
Display HEX/Verbose - toggles between HEX mode and interpreted mode of  
displaying SEL records.  
Output Text/Binary - toggles between whether the SEL events will be saved to the  
file in binary format or verbose format.  
·
·
Window - gives options for displaying currently open windows.  
Help  
¾ Help Topics - help topics for EMP Console.  
¾ Help About - provides version information.  
SDR Viewer  
The SDR Viewer lets you view the Sensor Data Records from the SDR repository. Options  
available through the SDR Viewer are:  
·
·
·
·
·
·
View all SDR records  
View SDR entries by SDR type  
View SDR summary info  
Set SDR display mode to either HEX or verbose mode  
Close the SDR Viewer  
Exit the EMP Console  
SDR Viewer Menu Options  
The following menu options are found on the SDR Viewer menu bar:  
·
File  
¾ Close - closes the SDR Viewer.  
¾ Exit - exits the EMP Console.  
View  
·
¾ Display all Records - displays all records from the SDR repository.  
¾ SDR Type - displays the records of a particular SDR type. Select an SDR type from a pop-  
up menu that displays all the SDR types available for the given hardware.  
¾ SDR Information - displays the SDR summary information as returned by the server.  
Settings - changes the operating parameters for the SDR Viewer. This menu displays the  
following suboption:  
·
¾ Display HEX/Verbose - toggles between HEX mode and interpreted mode of displaying  
SDR records.  
·
·
Window - gives options for displaying currently open windows.  
Help  
¾ Help Topics - help topics for EMP Console.  
¾ Help About - provides version information.  
L440GX+ Server Board Product Guide  
73  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FRU Viewer  
The FRU Viewer allows you to view the server's FRU (Field Replaceable Unit) data from the  
server's Front Panel FRU information area. The options available in the FRU Viewer are:  
·
·
·
·
·
View all FRU records  
View FRU summary info  
Set FRU display mode to either Hex or verbose mode  
Close the FRU Viewer  
Exit EMP Console  
FRU Viewer Menu Options  
The following menu options are found on the FRU Viewer menu bar:  
·
File  
¾ Close - closes the FRU Viewer.  
¾ Exit - exits EMP Console.  
View  
·
¾ Display all Records - displays all FRU data, which consists of chassis, board, and product  
information.  
¾ FRU Information - displays the FRU summary information as returned by the server.  
Settings - changes operating parameters for the FRU Viewer. This menu displays the  
following options:  
·
¾ Display HEX/Verbose - toggles between HEX mode and interpreted mode of displaying  
FRU records.  
·
·
Window - gives options for displaying currently open windows.  
Help  
¾ Help Topics - help topics for EMP Console.  
¾ Help About - provides version information.  
74  
Configuration Software and Utilities  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FRUSDR Load Utility  
The Field Replacement Unit (FRU) and Sensor Data Record (SDR) Load Utility is a DOS-based  
program used to update the server management subsystem’s product level FRU, SDR, and the  
Desktop Management Interface (DMI) nonvolatile storage components (EEPROMs). The  
load utility  
·
·
·
discovers the product configuration based on instructions in a master configuration file  
displays the FRU information  
updates the nonvolatile storage device (EEPROM) associated with the Baseboard Management  
Controller (BMC) that holds the SDR and FRU area  
·
·
updates the DMI area located in the BIOS nonvolatile storage device  
generically handles FRU devices that may not be associated with the BMC  
When to Run the FRUSDR Load Utility  
You should run the FRUSDR Load Utility each time you upgrade or replace the hardware in your  
server, excluding add-in boards, hard drives, and RAM. For example, if you replace an array of  
fans, you need to run the utility. It programs the sensors that need to be monitored for server  
management.  
Because the firmware must reload to properly initialize the sensors after programming, turn the  
server off and remove the AC power cords from the server. Wait approximately 30 seconds, and  
reconnect the power cords.  
What You Need to Do  
The FRUSDR Load Utility may be run directly from the Configuration Software CD or from a  
diskette you create from the CD. It can be extracted from the CD by booting to the CD and  
selecting “Make Diskettes” or by inserting the CD into a PC running Windows 95 or NT and  
selecting the “Utilities” section.  
NOTE  
/
If your diskette drive is disabled, or improperly configured, you must use  
BIOS Setup to enable it. If necessary, you can disable the drive after you are  
done with the FRUSDR utility.  
L440GX+ Server Board Product Guide  
75  
Download from Www.Somanuals.com. All Manuals Search And Download.  
How You Use the FRUSDR Load Utility  
This utility is compatible with ROM-DOS Ver. 6.22, MS-DOSVer. 6.22, and later versions. The  
utility accepts CFG, SDR and FRU load files. The executable file for the utility is frusdr.exe. The  
utility requires the following supporting files:  
·
·
·
one or more .fru files describing the system’s field replaceable units  
a .cfg file describing the system configuration  
a .sdr file describing the sensors in the system  
Command Line Format  
The basic command line format is  
frusdr [/?] [/h] [/d {dmi, fru, sdr}] [/cfg filename.cfg] /p  
Command  
frusdr  
Description  
Is the name of the utility.  
Displays usage information.  
Only displays requested area.  
Uses custom CFG file.  
Pause between blocks of data.  
/? or /h  
/d {dmi, fru, sdr}  
/cfg filename.cfg  
/p  
Parsing the Command Line  
The FRUSDR Load Utility allows only one command line function at a time. A command line  
function may consist of two parameters; for example, cfg filename.cfg. Any invalid parameters  
result in displaying an error message and exiting the program. You can use either a slash (/) or a  
minus sign (-) to specify command line options. The /p flag may be used in conjunction with any  
of the other options.  
Displaying Usage Information  
When the utility is run with the /? or /h command line flags, the following message is displayed:  
FRU & SDR Load Utility Version 3.0  
Usage: frusdr  
/? Or /h  
Is the name of the utility.  
Displays usage information.  
Only displays requested area.  
Uses custom CFG file.  
/d {dmi,fru,sdr}  
/cfg filename.cfg  
/p  
Pause between blocks of data.  
Displaying a Given Area  
When the utility is run with the /d DMI, /d FRU, or /d SDR command line flag, the indicated area is  
displayed. Each area represents a sensor; one sensor for each instrumented device in the server. If  
the given display function fails because of an inability to parse the data present or a hardware  
failure, the utility displays an error message and exits.  
76  
Configuration Software and Utilities  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Displaying DMI Area  
The DMI area is displayed in ASCII format when the field is ASCII or as a number when the field  
is a number. Each DMI area displayed is headed with the DMI area designated name. Each field  
has a field name header followed by the field in ASCII or as a number.  
Displaying FRU Area  
The FRU area is displayed in ASCII format when the field is ASCII or as a number when the field  
is a number. Each FRU area displayed is headed with the FRU area designated name. Each field  
has a field name header followed by the field in ASCII or as a number. The Board, Chassis, and  
Product FRU areas end with an END OF FIELDS CODE that indicates there is no more data in this  
area. The Internal Use area is displayed in hex format, 16 bytes per line.  
Displaying SDR Area  
The SDR nonvolatile storage area is displayed in the following hex format. The data is separated  
by a Sensor Record Number X header, where X is the number of that sensor record in the  
SDR area. The next line after the header is the sensor record data in hex format delineated by  
spaces. Each line holds up to 16 bytes. The data on each line is followed by the same data in  
ASCII format; nonprintable characters are substituted by a period (.).  
Using Specified CFG File  
The utility can be run with the command line parameter of -cfg filename.cfg. The filename can be  
any DOS accepted, eight-character filename string. The utility loads the specified CFG file and  
uses the entries in the configuration file to probe the hardware and to select the proper SDRs to load  
into nonvolatile storage.  
Displaying Utility Title and Version  
The utility displays its title:  
FRU & SDR Load Utility, Version 3.0  
Where X.XX is the revision number for the utility.  
Configuration File  
The configuration file is in ASCII text. The utility executes commands formed by the strings  
present in the configuration file. These commands cause the utility to perform various tasks needed  
to ultimately load the proper SDRs into the nonvolatile storage of the BMC and possibly generic  
FRU devices. Some of the commands may be interactive and require you to make a choice.  
Prompting for Product Level FRU Information  
Through the use of a Configuration File, the utility may prompt you for FRU information.  
Filtering Sensor Data Record From the SDR File  
The MASTER.SDR file has all the possible SDRs for the system. These records may need to be  
filtered based on the current product configuration. The configuration file directs the filtering of  
the SDRs.  
L440GX+ Server Board Product Guide  
77  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Updating the SDR Nonvolatile Storage Area  
After the utility validates the header area of the supplied SDR file, it updates the SDR repository  
area. Before programming, the utility clears the SDR repository area. The SDR file is loaded via  
the .cfg File. Then the utility filters all tagged SDRs depending on the product configuration set in  
the Configuration File. Nontagged SDRs are automatically programmed. The utility also copies all  
written SDRs to the SDR.TMP file. It contains an image of what was loaded, and the TMP file is  
also useful for debugging the server.  
Updating FRU Nonvolatile Storage Area  
After the configuration is determined, the utility updates the FRU nonvolatile storage area. First it  
verifies the Common Header area and checksum from the specified FRU file. The Internal Use  
Area is read out of the specified .FRU file and is programmed into the nonvolatile storage. The  
Chassis, Board, Product and MultiRecord areas are read out of the specified .FRU file, if they exist,  
then those areas are programmed into the FRU nonvolatile storage. All the areas are also written to  
the FRU.TMP file, which is useful for debugging the server.  
Updating DMI FRU Nonvolatile Storage Area  
After programming the BMC FRU area, the utility then programs the following Chassis, Board, and  
Product FRU information to the DMI fields, but only when dictated by the Configuration File.  
If a failure occurs, the utility displays an error message and exits.  
Cleaning Up and Exiting  
If an update was successfully performed, the utility displays an appropriate message and then exits  
with a DOS exit code of zero.  
If the utility fails, it immediately exits with an error message and a non-zero DOS exit code.  
78  
Configuration Software and Utilities  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Upgrading the BIOS  
Preparing for the Upgrade  
Before you upgrade the BIOS, prepare for the upgrade by recording the current BIOS settings,  
obtaining the upgrade utility, and making a copy of the current BIOS.  
Recording the Current BIOS Settings  
1. Boot the computer and press <F2>when you see the message:  
Press <F2> Key if you want to run SETUP  
2. Write down the current settings in the BIOS Setup program.  
NOTE  
/
Do not skip step 2. You will need these settings to configure your computer  
at the end of the procedure.  
Obtaining the Upgrade Utility  
You can upgrade to a new version of the BIOS using the new BIOS files and the BIOS upgrade  
utility, iFLASH.EXE. You can obtain the BIOS upgrade file and the iFLASH.EXE utility through  
your computer supplier or from the Intel Customer Support website:  
http://support.intel.com/support/motherboards/server/l440gx  
NOTE  
/
Please review the instructions distributed with the upgrade utility before  
attempting a BIOS upgrade.  
This upgrade utility allows you to:  
·
·
Upgrade the BIOS in flash memory.  
Update the language section of the BIOS.  
The following steps explain how to upgrade the BIOS.  
Creating a Bootable Floppy Diskette  
1. Use a DOS or Windows 95 system to create the floppy disk.  
2. Insert a floppy disk in floppy drive A.  
3. At the C:\ prompt, for an unformatted floppy disk, type:  
format a:/s  
or, for a formatted floppy disk, type:  
sys a:  
4. Press <Enter>  
L440GX+ Server Board Product Guide  
79  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Creating the BIOS Upgrade Floppy Diskette  
The BIOS upgrade file is a compressed self-extracting archive that contains the files you need to  
upgrade the BIOS.  
1. Copy the BIOS upgrade file to a temporary directory on your hard disk.  
2. From the C:\ prompt, change to the temporary directory.  
3. To extract the file, type the name of the BIOS upgrade file, for example:  
10006BI1.EXE  
4. Press <Enter>. The extracted file contains the following files:  
LICENSE.TXT  
README.TXT  
BIOS.EXE  
5. Read the LICENSE.TXTfile, which contains the software license agreement and the README.TXT  
file, which contains the instructions for the BIOS upgrade.  
6. Insert the bootable floppy disk into drive A.  
7. To extract the BIOS.EXEfile to the floppy disk, change to the temporary directory that holds the  
BIOS.EXEfile and type:  
BIOS A:  
8. Press <Enter>.  
9. The floppy disk now holds the BIOS upgrade and recovery files.  
Upgrading the BIOS  
1. Boot the computer with the floppy disk in drive A. The BIOS upgrade utility screen appears.  
2. Select Update Flash Memory From a File.  
3. Select Update System BIOS. Press <Enter>.  
4. Use the arrow keys to select the correct .biofile. Press <Enter>.  
5. When the utility asks for confirmation that you want to flash the new BIOS into memory,  
select Continue with Programming. Press <Enter>.  
6. When the utility displays the message upgrade is complete, remove the floppy disk.  
Press <Enter>.  
7. As the computer boots, check the BIOS identifier (version number) to make sure the upgrade  
was successful.  
8. To enter the Setup program, press <F2>when you see the message:  
Press <F2> Key if you want to run SETUP  
9. For proper operation, load the Setup program defaults. To load the defaults, press <F9>.  
10. To accept the defaults, press <Enter>.  
11. Set the options in the Setup program to the settings you wrote down before the BIOS upgrade.  
12. To save the settings, press <F10>.  
13. To accept the settings, press <Enter>.  
14. Turn off the computer and reboot.  
80  
Configuration Software and Utilities  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Recovering the BIOS  
It is unlikely that anything will interrupt the BIOS upgrade; however, if an interruption occurs, the  
BIOS could be damaged. The following steps explain how to recover the BIOS if an upgrade fails.  
The following procedure use recovery mode for the Setup program.  
NOTE  
/
Because of the small amount of code available in the nonerasable boot block  
area, there is no video support. You will not see anything on the screen  
during the procedure. Monitor the procedure by listening to the speaker and  
looking at the floppy drive LED.  
1. Turn off all peripheral devices connected to the computer. Turn off the computer.  
2. Remove the computer cover.  
3. Locate jumper block J3J2.  
4. Move the Recovery Boot jumper from pins 9-10 to pins 10-11 (see Figure 17 on page 99).  
5. Insert the bootable BIOS upgrade floppy disk into floppy drive A.  
6. Replace the cover, turn on the computer, and allow it to boot. The recovery process will take a  
few minutes.  
7. Listen to the speaker.  
8. Two beeps and the end of activity in drive A indicate successful BIOS recovery.  
9. A series of continuous beeps indicates failed BIOS recovery.  
10. If recovery fails, return to step 1 and repeat the recovery process.  
11. If recovery is successful, turn off the computer. Remove the computer cover and continue with  
the following steps.  
12. Move the Recovery Boot jumper back to pins 9-10.  
13. Replace the computer cover. Leave the upgrade disk in drive A and turn on the computer.  
14. Continue with the BIOS upgrade (see page 80).  
Changing the BIOS Language  
You can use the BIOS upgrade utility to change the language the BIOS uses for messages and the  
Setup program. Use a bootable floppy disk containing the Intel flash utility and language files.  
1. Boot the computer with the bootable floppy disk in drive A. The BIOS upgrade utility screen  
appears.  
2. Select Update Flash Memory From a File.  
3. Select Update Language Set. Press <Enter>.  
4. Select drive A and use the arrow keys to select the correct .lngfile. Press <Enter>.  
5. When the utility asks for confirmation that you want to flash the new language into memory,  
select Continue with Programming. Press <Enter>.  
6. When the utility displays the message upgrade is complete, remove the floppy disk. Press  
<Enter>.  
7. The computer will reboot and the changes will take effect.  
L440GX+ Server Board Product Guide  
81  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using the Firmware Update Utility  
The Firmware Update Utility is a DOS-based program used to update the Baseboard Management  
Controller’s firmware code. You only need to run the Firmware Update Utility if new firmware  
code becomes necessary.  
Running the Firmware Update Utility  
1. Create a DOS bootable diskette. The version of DOS must be 6.0 or higher.  
2. Place the firmware update utility (FWUPDATE.EXE) and the *.hex file on the diskette. Make  
a note of the *.hex file name, you will need it later.  
3. Insert the diskette into the drive and boot to it.  
4. At the DOS prompt, run the executable file (FWUPDATE.EXE).  
5. The utility will display a menu screen. Select “Upload Flash.”  
6. The utility will ask for a file name. Enter the name of the *.hex file.  
7. The program will load the file and then ask if it should “Upload Boot Block.” Press “N” to  
continue.  
8. The program will next ask if it should “Upload Operational Code.” Press “Y” to continue.  
9. Once the operational code has been updated and verified, press any key to continue. Then  
press the “ESC” key to exit the program.  
10. Shut the system down and remove any floppy disks that may be in the system.  
11. Disconnect the AC power cord from the system and wait 60 seconds.  
12. Connect the AC power cord and power up the system.  
Installing Video Drivers  
After configuring the system, you need to install video drivers to take full advantage of the features  
of the onboard Cirrus Logic CL-GD5480 super VGA video controller.  
·
The L440GX+ Resource CD includes video drivers for use with DOS and Windows NT.  
Check the README.TXT file on the CD for information on installing these drivers.  
For other operating systems, see your OS instructions for installing device drivers.  
·
82  
Configuration Software and Utilities  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using the Adaptec SCSI Utility  
The Adaptec SCSI utility detects the SCSI host adapters on the server board. The utility runs out of  
BIOS and is used to  
·
·
Change default values  
Check and/or change SCSI device settings that may conflict with those of other devices in the  
server  
Running the SCSI Utility  
1. When this message appears on the video monitor:  
Press Ctrl-A to run SCSI Utility...  
2. Press <Ctrl+A> to run this utility. When it appears, choose the host adapter that you want to  
configure.  
Another Adaptec utility that is available on the L440GX+ Resource CD is the Adaptec EZ  
SCSI utility. It is designed to be installed from diskettes on to a DOS or Windows operating  
system.  
L440GX+ Server Board Product Guide  
83  
Download from Www.Somanuals.com. All Manuals Search And Download.  
84  
Configuration Software and Utilities  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 Solving Problems  
This chapter helps you identify and solve problems that might occur while you are using the  
system.  
Resetting the System  
To do this:  
Press:  
<Ctrl+Alt+Del>  
Soft boot reset, which clears system memory and reloads the  
operating system.  
Clear system memory, restart POST, and reload the operating  
system.  
Reset button  
Power off/on  
Cold boot reset. Turn the system power off and then on. This  
clears system memory, restarts POST, reloads the operating  
system, and halts power to all peripherals.  
Fault Resilient Booting  
Fault resilient booting insures the system will not stop from a boot problem. Two sets of timers are  
implemented in the BMC that will automatically reset the system if the system should halt for some  
reason.  
·
FRB 2 - 5 sec timer. If the primary processor does not come up in 5 seconds the system will  
automatically reset and switch to the secondary processor (if installed). If a second processor is  
not installed, the system will try to restart off the primary processor.  
·
FRB 3 - 7 minute timer. If the system does not make it up to the end of POST in 7 minutes, the  
system will automatically reset and try again. It is assumed that the processor failed regardless  
of what may have caused the system to hang. The primary processor is taken off line and the  
system will boot off the secondary (if installed otherwise it will try to restart again off of the  
primary). Bad memory or a bad plug in card may cause an FRB 3 failure.  
All failures are logged to the system event log.  
The system will remember all FRB errors and display them at the end of POST until you select the  
Processor Retest option from the BIOS Setup utility.  
Initial System Startup  
Problems that occur at initial system startup are usually caused by incorrect installation or  
configuration. Hardware failure is a less frequent cause.  
85  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Checklist  
q Are all cables correctly connected and secured?  
q Are the processors or processor termination board fully seated in their slots on the server  
board?  
q Are all add-in ISA and PCI boards fully seated in their slots on the server board?  
q Are all switch and jumper settings on the server board correct?  
q Are all jumper and switch settings on add-in boards and peripheral devices correct? To check  
these settings, refer to the manufacturer’s documentation that comes with them. If applicable,  
ensure that there are no conflicts—for example, two add-in boards sharing the same interrupt.  
q Are all SDRAM DIMMs installed correctly?  
q Are all peripheral devices installed correctly?  
q If the system has a hard disk drive, is it properly formatted or configured?  
q Are all device drivers properly installed?  
q Are the configuration settings made with the SSU correct?  
q Is the operating system properly loaded? Refer to the operating system documentation.  
q Did you press the system power on/off switch on the front panel to turn the server on (power on  
light should be lit)?  
q Is the system power cord properly connected to the system and plugged into a  
NEMA 5-15R outlet for 100-120 V~ or a NEMA 6-15R outlet for 200-240 V~?  
q Is AC power available at the wall outlet?  
q Are all integrated components from the tested components lists? Check the tested memory, and  
chassis lists, as well as the supported hardware and operating system list on the Intel Customer  
Support website:  
http://support.intel.com/support/motherboards/server/l440gx/compat.htm  
Running New Application Software  
Problems that occur when you run new application software are usually related to the software.  
Faulty equipment is much less likely, especially if other software runs correctly.  
Checklist  
q Does the system meet the minimum hardware requirements for the software? See the software  
documentation.  
q Is the software an authorized copy? If not, get one; unauthorized copies often do not work.  
q If you are running the software from a diskette, is it a good copy?  
q If you are running the software from a CD-ROM disk, is the disk scratched or dirty?  
q If you are running the software from a hard disk drive, is the software correctly installed? Were  
all necessary procedures followed and files installed?  
q Are the correct device drivers installed?  
q Is the software correctly configured for the system?  
q Are you using the software correctly?  
If the problems persist, contact the software vendor’s customer service representative.  
86  
Solving Problems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
After the System Has Been Running Correctly  
Problems that occur after the system hardware and software have been running correctly often  
indicate equipment failure. Many situations that are easy to correct, however, can also cause such  
problems.  
Checklist  
q If you are running the software from a diskette, try a new copy of the software.  
q If you are running the software from a CD-ROM disk, try a different disk to see if the problem  
occurs on all disks.  
q If you are running the software from a hard disk drive, try running it from a diskette. If the  
software runs correctly, there may be a problem with the copy on the hard disk drive. Reinstall  
the software on the hard disk, and try running it again. Make sure all necessary files are  
installed.  
q If the problems are intermittent, there may be a loose cable, dirt in the keyboard (if keyboard  
input is incorrect), a marginal power supply, or other random component failures.  
q If you suspect that a transient voltage spike, power outage, or brownout might have occurred,  
reload the software and try running it again. (Symptoms of voltage spikes include a flickering  
video display, unexpected system reboots, and the system not responding to user commands.)  
NOTE  
/
Random errors in data files: If you are getting random errors in your data  
files, they may be getting corrupted by voltage spikes on your power line. If  
you are experiencing any of the above symptoms that might indicate voltage  
spikes on the power line, you may want to install a surge suppressor between  
the power outlet and the system power cord.  
L440GX+ Server Board Product Guide  
87  
Download from Www.Somanuals.com. All Manuals Search And Download.  
More Problem Solving Procedures  
This section provides a more detailed approach to identifying a problem and locating its source.  
Preparing the System for Diagnostic Testing  
CAUTION  
Turn off devices before disconnecting cables: Before disconnecting any  
peripheral cables from the system, turn off the system and any external  
peripheral devices. Failure to do so can cause permanent damage to the  
system and/or the peripheral devices.  
1. Turn off the system and all external peripheral devices. Disconnect all of them from the  
system, except the keyboard and video monitor.  
2. Make sure the system power cord is plugged into a properly grounded AC outlet.  
3. Make sure your video display monitor and keyboard are correctly connected to the system.  
Turn on the video monitor. Set its brightness and contrast controls to at least two thirds of their  
maximum ranges (see the documentation supplied with your video display monitor).  
4. If the operating system normally loads from the hard disk drive, make sure there is no diskette  
in drive A. Otherwise, place a diskette containing the operating system files in drive A.  
5. Turn on the system. If the power LED does not light, see “Power Light Does Not Light” on  
page 89.  
Monitoring POST  
See Chapter 3.  
Verifying Proper Operation of Key System Lights  
As POST determines the system configuration, it tests for the presence of each mass storage device  
installed in the system. As each device is checked, its activity light should turn on briefly. Check  
for the following:  
q Does the diskette drive activity light turn on briefly? If not, see “Diskette Drive Activity Light  
Does Not Light” on page 91.  
q If a second diskette drive is installed, does its activity light turn on briefly? If not, see “Diskette  
Drive Activity Light Does Not Light” on page 91.  
q If there is a hard disk drive or SCSI devices installed in the system, does the hard disk drive  
activity light on the control panel turn on briefly? If not, see “Hard Disk Drive Activity Light  
Does Not Light" on page 91.  
Confirming Loading of the Operating System  
Once the system boots up, the operating system prompt appears on the screen. The prompt varies  
according to the operating system. If the operating system prompt does not appear, see “Initial  
System Startup” on page 85.  
88  
Solving Problems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specific Problems and Corrective Actions  
This section provides possible solutions for these specific problems:  
·
·
·
·
·
·
·
·
·
·
Power light does not light.  
There is no beep or an incorrect beep pattern.  
No characters appear on screen.  
Characters on the screen appear distorted or incorrect.  
System cooling fans do not rotate.  
Diskette drive activity light does not light.  
Hard disk drive activity light does not light.  
CD-ROM drive activity light does not light.  
There are problems with application software.  
The bootable CD-ROM is not detected.  
Try the solutions in the order given. If you cannot correct the problem, contact your service  
representative or authorized dealer for help.  
Power Light Does Not Light  
Check the following:  
q Is the system operating normally? If so, the power LED is probably defective or the cable from  
the front panel to the server board is loose.  
q Are there other problems with the system? If so, check the items listed under “System Cooling  
Fans Do Not Rotate Properly.”  
If all items are correct and problems persist, contact your service representative or authorized dealer  
for help.  
No Characters Appear on Screen  
Check the following:  
q Is the keyboard functioning? Check to see that the “Num Lock” light is functioning.  
q Is the video monitor plugged in and turned on?  
q Are the brightness and contrast controls on the video monitor properly adjusted?  
q Are the video monitor switch settings correct?  
q Is the video monitor signal cable properly installed?  
q Is the onboard video controller enabled?  
If you are using an add-in video controller board, do the following:  
1. Verify that the video controller board is fully seated in the server board connector.  
2. Reboot the system for changes to take effect.  
L440GX+ Server Board Product Guide  
89  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. If there are still no characters on the screen after you reboot the system and POST emits a beep  
code, write down the beep code you hear. This information is useful for your service  
representative. See “Port-80 Codes and Countdown Codes” on page 94.  
4. If you do not receive a beep code and characters do not appear, the video display monitor or  
video controller may have failed. Contact your service representative or authorized dealer  
for help.  
Characters Are Distorted or Incorrect  
Check the following:  
q Are the brightness and contrast controls properly adjusted on the video monitor? See the  
manufacturer’s documentation.  
q Are the video monitor signal and power cables properly installed?  
If the problem persists, the video monitor may be faulty or it may be the incorrect type. Contact  
your service representative or authorized dealer for help.  
System Cooling Fans Do Not Rotate Properly  
If the system cooling fans are not operating properly, system components could be damaged.  
Check the following:  
q Is AC power available at the wall outlet?  
q Is the system power cord properly connected to the system and the wall outlet?  
q Did you press the power button?  
q Is the power on light lit?  
q Have any of the fan motors stopped (use the server management subsystem to check the fan  
status)?  
q Are the fan power connectors properly connected to the server board?  
q Is the cable from the front panel board connected to the server board?  
q Are the power supply cables properly connected to the server board?  
q Are there any shorted wires caused by pinched cables or power connector plugs forced into  
power connector sockets the wrong way?  
If the switches and connections are correct and AC power is available at the wall outlet, contact  
your service representative or authorized dealer for help.  
90  
Solving Problems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Diskette Drive Activity Light Does Not Light  
Check the following:  
q Are the diskette drive power and signal cables properly installed?  
q Are all relevant switches and jumpers on the diskette drive set correctly?  
q Is the diskette drive properly configured?  
q Is the diskette drive activity light always on? If so, the signal cable may be plugged in  
incorrectly.  
If you are using the onboard diskette controller, use the SSU to make sure that “Onboard Floppy” is  
set to “Enabled.” If you are using an add-in diskette controller, make sure that “Onboard Floppy”  
is set to “Disabled.” To run the SSU, see Chapter 3.  
If the problem persists, there may be a problem with the diskette drive, server board, or drive signal  
cable. Contact your service representative or authorized dealer for help.  
Hard Disk Drive Activity Light Does Not Light  
If you have installed one or more hard disk drives in your system, check the following:  
q Are the power and signal cables to the drive properly installed?  
q Are all relevant switches and jumpers on the hard drive and adapter board set correctly?  
q Is the onboard IDE controller enabled? (IDE hard drives only)  
q Is the hard disk drive properly configured?  
NOTE  
/
Front panel hard disk LED indicates IDE and SCSI devices: The hard  
disk drive activity light on the front panel lights when either an IDE hard  
disk drive, or a SCSI device controlled by the onboard SCSI host controller,  
is in use. This LED does not display CD-ROM activity.  
CD-ROM Drive Activity Light Does Not Light  
Check the following:  
q Are the power and signal cables to the CD-ROM drive properly installed?  
q Are all relevant switches and jumpers on the drive set correctly?  
q Is the drive properly configured?  
q Is the onboard IDE controller enabled?  
L440GX+ Server Board Product Guide  
91  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTE  
/
Front panel hard disk LED indicates IDE and SCSI devices: The hard  
disk drive activity light on the front panel lights when either an IDE hard  
disk drive, or a SCSI device controlled by the onboard SCSI host controller,  
is in use. This LED does not display CD-ROM activity.  
Cannot Connect to a Server  
q Make sure you are using the drivers that are shipped on the system Configuration Software CD  
for the onboard network controller.  
q Make sure the driver is loaded and the protocols are bound.  
q Make sure the network cable is securely attached to the connector at the system back panel and  
that the network controller Link LED is on (visible at back panel). If the cable is attached but  
the problem persists, try a different cable.  
q Make sure the hub port is configured for the same duplex mode as the network controller.  
q Check with your LAN administrator about the correct networking software that needs to be  
installed.  
q If you are directly connecting two servers (no hub), you will need a crossover cable (see your  
hub documentation for more information on crossover cables).  
q Check the network controller LEDs that are visible through an opening at the system back  
panel.  
Problems with Network  
The server hangs when the drivers are loaded.  
q Change the PCI BIOS interrupt settings. Try the “PCI Installation Tips” below.  
Diagnostics pass, but the connection fails.  
q Make sure the network cable is securely attached.  
q Make sure you specify the correct frame type in your NET.CFG file.  
The Link LED doesn’t light.  
q Make sure you have loaded the network drivers.  
q Check all cable connections.  
q Try another port on the hub.  
q Make sure you have the correct type of cable between the adapter and the hub. Some hubs  
require a crossover cable while others require a straight through cable (for more information on  
crossover cabling, see your hub documentation).  
The Activity LED doesn’t light.  
q Make sure you’ve loaded the correct network drivers.  
q Network may be idle. Try accessing a server.  
92  
Solving Problems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The controller stopped working when an add-in adapter was installed.  
q Make sure the cable is connected to the port from the onboard network controller.  
q Make sure your PCI BIOS is current. Try the “PCI Installation Tips” below.  
q Make sure the other adapter supports shared interrupts. Also, make sure your operating system  
supports shared interrupts; OS/2does not.  
q Try reseating the add in adapter.  
The add-in adapter stopped working without apparent cause.  
q Try reseating the adapter first; then try a different slot if necessary.  
q The network driver files may be corrupt or deleted. Delete and then reinstall the drivers.  
q Run the diagnostics.  
PCI Installation Tips  
Some common PCI tips are listed here.  
q Reserve interrupts (IRQs) and/or memory addresses specifically for ISA adapters. This  
prevents PCI cards from trying to use the same settings ISA cards are using. Use the SSU to  
keep track of ISA adapter resources.  
q Certain drivers may require interrupts that are not shared with other PCI drivers. The SSU can  
be used to adjust the interrupt numbers for PCI devices. For certain drivers, it may be  
necessary to alter settings so that interrupts are not shared.  
Problems with Application Software  
If you have problems with application software, do the following:  
q Verify that the software is properly configured for the system. See the software installation and  
operation documentation for instructions on setting up and using the software.  
q Try a different copy of the software to see if the problem is with the copy you are using.  
q Make sure all cables are installed correctly.  
q Verify that the server board jumpers are set correctly. See Chapter 5.  
q If other software runs correctly on the system, contact your vendor about the failing software.  
If the problem persists, contact the software vendor’s customer service representative for help.  
Bootable CD-ROM Is Not Detected  
Check the following:  
q Is the BIOS set to allow the CD-ROM to be the first bootable device?  
L440GX+ Server Board Product Guide  
93  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Error and Informational Messages  
When you turn on the system, POST displays messages that provide information about the system.  
If a failure occurs, POST emits beep codes that indicate errors in hardware, software, or firmware.  
If POST can display a message on the video display screen, it causes the speaker to beep twice as  
the message appears.  
Port-80 Codes and Countdown Codes  
After the video adapter has been successfully initialized, the BIOS indicates the current testing  
phase during POST after the video adapter has been successfully initialized by outputting a 2-digit  
hex code to I/O location 80h. If a port-80h ISA POST card is installed, it displays the 2-digit code  
on a pair of hex display LEDs.  
POST Error Codes and Messages  
The following error codes and messages are representative of various conditions BIOS identifies.  
The exact strings and error numbers may be different from those listed here.  
94  
Solving Problems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5 Technical Reference  
This chapter includes the following:  
·
·
·
Environmental specifications  
Board interrupts  
Electromagnetic Compatibility (EMC) notices  
95  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connectors  
The figure shows connector locations on the server board. This section provides pin information  
about the connectors.  
Figure 15. Connector Locations  
A. Fansink connector 2  
I.  
ISOL IMB  
B. Fansink connector 1  
C. Main power connector  
D. ATX Aux power connector  
E. SM IMB  
J.  
Fan connector 1  
K. Server monitor module (SMM) connector  
L. External Wake on LAN connector  
M. Hard drive LED connector  
N. ICMB header  
F. Fan connector 2A  
G. ATX front panel connector  
H. Front panel connector, 16 pin  
O. Chassis intrusion connector  
P. Fan connector 2B  
96  
Technical Reference  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ATX Style Front Panel Connector  
Figure 16. ATX Style Front Panel Connector  
Table 8.  
ATX Style Front Panel Connector Pinout  
Pin  
Connector  
Signal  
Power switch  
GND  
A.  
Power switch  
1
2
3
N/C  
B.  
Hard drive activity LED  
4
5
6
7
Current limited +5V  
Key  
HD activity LED  
Current limited +5V  
C.  
D.  
Speaker  
8
9
10  
11  
GND  
N/C  
PIEZO_IN  
SPKR_HDR  
Power LED  
12  
13  
14  
15  
Current limited +5V  
N/C  
GND  
N/C  
E.  
F.  
Reset switch  
Sleep switch  
16  
17  
GND  
Reset switch  
18  
19  
GND  
Sleep switch  
L440GX+ Server Board Product Guide  
97  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Main Power Connector  
Table 9.  
Main Power Connector Pinout  
Pin  
1
Signal  
+3.3V  
+3.3V  
COM  
Pin  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
Signal  
+3.3V  
-12V  
COM  
PS_ON  
COM  
COM  
COM  
-5V  
2
3
4
+5V  
5
COM  
6
+5V  
7
COM  
8
PWR_OK  
+5VSB  
+12V  
+12V  
+3.3V  
9
+5V  
10  
11  
12  
+5V  
+5V  
COM  
Fan Interface  
The server board has five 3-pin fan connectors that are shrouded and keyed. Two are located next  
to the processor sockets (one for each processor); each is intended to be used for a tachometer fan  
heat sink.  
NOTE  
/
Fan connectors 2A and 2B can not be used simultaneously. If you plug fans  
into both connectors, the fans will not operate properly.  
Table 10. Fan Connector Pinout  
Pin  
1
Signal  
GND  
2
+12V  
3
Fan Sensor  
98  
Technical Reference  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Server Board Jumpers  
Figure 17. Jumper Locations  
Table 11. Server Board Jumper Summary  
Jumper Block  
Jumper Name  
Pins (default in bold)  
What it does at system reset  
J5A2  
WOL ENABLE  
1-2, Disabled  
Disables Wake On LAN. If your power  
supply does not provide 0.8 A of +5 V  
Standby current, you must move the WOL  
Enable jumper to this position.  
2-3, Enabled  
Enables Wake On LAN.  
J4J2  
J3J1  
BMC WR EN  
FRB  
1-2, Protect  
BMC boot block is write protected.  
2-3, Erase/Program  
BMC boot block is erasable and  
programmable.  
1-2, Enable  
FRB operation is enabled (system boots  
from processor 1 if processor 0 does not  
respond).  
2-3, Disable  
FRB is disabled.  
J3J1  
J3J1  
INT DET  
5-6, Enable  
Switch installed on chassis indicates when  
cover has been removed.  
6-7, Disable  
Chassis intrusion switch is bypassed.  
System boots normally.  
BMC FRC UP  
9-10, Normal  
10-11, Program  
System attempts to update BMC firmware.  
continued  
L440GX+ Server Board Product Guide  
99  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 11. Server Board Jumper Summary (continued)  
Jumper Block Jumper Name  
Pins (default in bold)  
1-2, Protect  
What it does at system reset  
J2J1  
CMOS CLR  
Preserves the contents of NVRAM.  
2-3, Erase  
Replaces the contents of NVRAM with the  
manufacturing default settings.  
J2J1  
J2J1  
PSWD CLR  
5-6, Protect  
6-7, Erase  
Maintains the current system password.  
Clears the password.  
RCVRY BOOT  
9-10, Normal  
System attempts to boot using the BIOS  
stored in flash memory.  
10-11, Recovery  
BIOS attempts a recovery boot, loading  
BIOS code from a floppy diskette into the  
flash device. This is typically used when the  
BIOS code has been corrupted.  
J2J1  
BIOS WR EN  
13-14, Protect  
BIOS boot block is write-protected.  
14-15, Erase/Program  
BIOS boot block is erasable and  
programmable.  
General Procedure to Change Jumper Setting  
The short general procedure for changing a configuration setting is the same for most of the jumper  
functions, so we will describe it here.  
1. Observe the safety and ESD precautions at the beginning of this chapter.  
2. Turn off all connected peripherals, turn off system power, and disconnect the AC power cord.  
3. Remove the side cover. You do not need to remove the server board from the chassis, and you  
probably do not need to remove any add-in boards.  
4. Locate the configuration jumpers at the edge of the server board toward the front of the system.  
5. Move jumper to pins specified for the desired setting.  
6. Reinstall the side cover, connect the power cord, and turn on the system for the change to take  
effect.  
7. You may need to repeat these steps to move the jumper back to its original setting, depending  
on the jumper function.  
100  
Technical Reference  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CMOS Jumper  
The jumper at pins 1, 2, and 3 controls whether settings stored in CMOS nonvolatile memory  
(NVRAM) are retained during a system reset.  
Procedure to restore the system’s CMOS and RTC to default values:  
1. See “General Procedure to Change Jumper Setting” on page 100.  
2. Move the CMOS jumper from pins 1 and 2 to pins 2 and 3 (the Clear CMOS memory position).  
3. Reinstall the side cover for your safety, and connect the power cord to the system.  
4. Turn the system on. Wait for POST to complete and for the messages “NVRAM cleared by  
jumper” and “Press F2 to enter Setup” to appear. This automatically reprograms CMOS and  
RTC to their default settings.  
5. Enter Setup and make any changes necessary (for example, changing the boot device). Press  
F10 to save the new Setup configuration and exit Setup.  
6. Turn off the system, and disconnect the power cord from the system.  
7. Again remove the side cover.  
8. Move the jumper from pins 2 and 3 back to pins 1 and 2 (the Protect CMOS memory position).  
9. Reinstall the side cover, and connect the power cord to the system.  
10. Run BIOS Setup or the SSU to verify the correct settings. See Chapter 3.  
Password Jumper  
The jumper at pins 5, 6, and 7 controls whether the user and administrative passwords are retained  
or cleared during a system reset.  
Procedure to clear the current password and then enter a new one:  
1. See “General Procedure to Change Jumper Setting” on page 100.  
2. Move the Password jumper from pins 5 and 6 to pins 6 and 7.  
3. Reinstall the side cover for your safety, and connect the power cord to the system.  
4. Turn the system on, and wait for POST to complete. This automatically clears the password.  
5. Turn off the system, and disconnect the power cord.  
6. Again remove the side cover.  
7. Move the jumper from pins 6 and 7 back to pins 5 and 6.  
8. Reinstall the side cover, and connect the power cord to the system.  
9. Run the SSU to specify a new password. See Chapter 3.  
L440GX+ Server Board Product Guide  
101  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Recovery Boot Jumper  
The jumper at pins 9, 10, and 11 controls whether the system attempts to boot using the BIOS  
programmed in the boot block area of the FLASH memory. This should be used only if the  
operational area of the BIOS is corrupted or needs to be upgraded. Contact your local service  
representative before doing this.  
Procedure to disable recovery booting:  
1. See “General Procedure to Change Jumper Setting” on page 100.  
2. Move the recovery boot jumper from pins 9 and 10 to pins 10 and 11.  
3. Reinstall the side cover for your safety, connect the power cord to the system.  
4. Turn the system on, and insert the Flash Memory Update Utility diskette in drive A. After the  
system boots, the speaker emits a single beep and the recovery process starts. This takes about  
three minutes. When the recovery process completes, the speaker emits two beeps.  
While in the recovery mode, there is no screen display on the monitor. The keyboard is disabled as  
the system automatically recovers the BIOS. The following beep codes describe the recovery  
status.  
Beep Code  
Message  
2
4
Successful completion, no errors.  
The system could not boot from the diskette. The diskette may not be  
bootable.  
Continuous series of low beeps  
The wrong BIOS recovery files are being used and/or the flash memory  
jumper is in the wrong position.  
5. Turn the system off, disconnect the power cord(s) from the system, and remove the left side  
cover.  
6. Move the jumper from pins 9 and 10 to pins 10 and 11 to enable the normal boot mode.  
7. Replace the left side cover, remove the diskette from drive A, and connect the power cord(s) to  
the system.  
8. After running the special recovery mode, run the SSU to specify a new password. See  
Chapter 3.  
Boot Block Write Protect Jumper  
The jumper at pins 13, 14, and 15 controls whether the BIOS boot block is protected from being  
erased and reprogrammed.  
CAUTION  
Leave boot block jumper at factory default setting: Programming the  
boot block incorrectly will prevent the system from booting. Programming  
should be done only by a technically qualified person. The procedure  
requires a special “Boot Block Update Utility.” Contact your dealer or sales  
representative for more information.  
102  
Technical Reference  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Procedure to permit boot block erasing and programming:  
1. See “General Procedure to Change Jumper Setting” on page 100.  
2. Move the boot block jumper from pins 13 and 14 to pins 14 and 15 to erase and program the  
BIOS boot block.  
3. Reinstall the side cover for your safety, and connect the power cord to the system.  
4. Run the Boot Block Update Utility.  
5. Turn off the system, and disconnect the power cord from the system.  
6. Remove the side cover.  
7. Move the jumper from pins 14 and 15 back to pins 13 and 14 to write protect the BIOS boot  
block.  
8. Reinstall the side cover, and connect the power cord to the system.  
FRB Timer Enable Jumper  
The jumper at pins 5, 6, and 7 controls the FRB timers. See page 85.  
Procedure to disable FRB timer:  
1. See “General Procedure to Change Jumper Setting” on page 100.  
2. Move the recovery boot jumper from pins 5 and 6 to pins 6 and 7.  
3. Reinstall the side cover for your safety, and connect the power cord to the system.  
4. Turn the system on, and wait for POST to complete.  
5. Run the SSU to configure the system. See Chapter 3.  
Chassis Intrusion Detection Jumper  
The chassis contains an alarm switch that sends a notification signal to the server management  
software if a cover is removed. The jumper at pins 9, 10, and 11 controls whether this alarm feature  
is enabled or disabled.  
Procedure to disable (bypass) the chassis intrusion switch:  
1. See “General Procedure to Change Jumper Setting” on page 100.  
2. Move the chassis intrusion detection jumper from pins 9 and 10 to pins 10 and 11 to disable the  
alarm switch.  
3. Reinstall the side cover for your safety, and connect the power cord to the system.  
4. Turn the system on, and wait for POST to complete.  
5. Run the SSU to configure the system. See Chapter 3.  
To enable the intrusion switch, do the above steps but move the jumper back to pins 9 and 10.  
L440GX+ Server Board Product Guide  
103  
Download from Www.Somanuals.com. All Manuals Search And Download.  
104  
Technical Reference  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6 Regulatory and Integration Information  
Regulatory Compliance  
This server baseboard complies with the following safety and EMC regulations when correctly  
installed in a compatible host system.  
Table 12. Safety Regulations  
Regulation  
Title  
UL 1950/CSA950, 3rd edition,  
Dated 07-28-95  
EN 60950, 2nd Edition, 1992  
Bi-National Standard for Safety of Information Technology Equipment  
including Electrical Business Equipment. (USA and Canada)  
The Standard for Safety of Information Technology Equipment including  
(with Amendments 1, 2, 3, and 4) Electrical Business Equipment. (European Community)  
IEC 950, 2nd edition, 1991  
The Standard for Safety of Information Technology Equipment including  
(with Amendments 1, 2, 3, and 4) Electrical Business Equipment. (International)  
EMKO-TSE (74-SEC) 207/94  
Summary of Nordic deviations to EN 60950. (Norway, Sweden,  
Denmark, and Finland)  
Table 13. EMC Regulations  
Regulation  
Title  
Title 47 of the Code of Federal Regulations, Parts 2 and 15, Subpart B,  
pertaining to unintentional radiators. (USA)  
FCC Class B  
CISPR 22, 2nd Edition, 1993  
(Class B)  
Limits and methods of measurement of Radio Interference Characteristics  
of Information Technology Equipment. (International)  
Implementation Regulations for Voluntary Control of Radio Interference by  
Data Processing Equipment and Electronic Office Machines. (Japan)  
VCCI Class B (ITE)  
EN55022 (1994) (Class B)  
EN50082-1 (1992)  
ICES-003 (1997)  
Limits and methods of measurement of Radio Interference Characteristics  
of Information Technology Equipment. (Europe)  
Generic Immunity Standard; Currently compliance is determined via  
testing to IEC 801-2, -3, and -4. (Europe)  
Interference-Causing Equipment Standard, Digital Apparatus, Class B  
(Including CRC c.1374). (Canada)  
This printed circuit assembly has the following product certification markings  
·
UL Joint Recognition Mark: Consists of small c followed by a stylized backward UR and  
followed by a small US (Component side)  
·
Manufacturer’s recognition mark: Consists of a unique UL recognized manufacturer’s logo,  
along with a flammability rating (94V-0) (Solder side)  
·
·
·
UL File Number for motherboards: E139761 (Component side)  
PB Part Number: Intel bare circuit board part number XXXXXX-ZZZ (Solder side)  
Battery “+” marking: located on the component side of the board in close proximity to the  
battery holder  
·
·
CE Mark: (Component side) The CE mark should also be on the shipping container  
Australian C-Tick Mark: Consists of solid circle with white check mark and supplier  
code N232  
105  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
CAUTION  
Follow these guidelines to meet safety and regulatory requirements when  
installing this board assembly.  
Read and adhere to all of these instructions and the instructions supplied with the host computer  
and associated modules. If the instructions for the host computer are inconsistent with these  
instructions or the instructions for associated modules, contact the supplier’s technical support to  
find out how you can ensure that your computer meets safety and regulatory requirements. If you  
do not follow these instructions and the instructions provided by host computer and module  
suppliers, you increase safety risk and the possibility of noncompliance with regional laws and  
regulations.  
Ensure EMC  
Before computer integration, make sure that the host chassis, power supply, and other modules  
have passed EMC certification testing.  
In the installation instructions for the host chassis, power supply, and other modules pay close  
attention to the following:  
·
Certifications (See “Ensure Host Computer and Accessory Module Certifications” on  
page 107.)  
·
·
·
External I/O cable shielding and filtering  
Mounting, grounding, and bonding requirements  
Keying connectors when mismating of connectors could be hazardous  
If the host chassis, power supply, and other modules have not passed applicable EMC certification  
testing before integration, EMC testing must be conducted on a representative sample of the newly  
completed computer.  
106  
Regulatory and Integration Information  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ensure Host Computer and Accessory Module Certifications  
Make sure that the host computer, any added subassembly (such as a board or drive assembly,  
including internal or external wiring), are certified for the region(s) where the end product will be  
used. Marks on the product are proof of certification. Certification marks are as follows:  
In Europe  
The CE marking signifies compliance with all relevant European requirements. If the host  
computer does not bear the CE marking, obtain a supplier’s Declaration of Conformity to the  
appropriate standards required by the European EMC Directive and Low Voltage Directive. Other  
directives, such as the Machinery and Telecommunications Directives, may also apply depending  
on the type of product. No regulatory assessment is necessary for low voltage DC wiring used  
internally or wiring used externally when provided with appropriate overcurrent protection.  
Appropriate protection is provided by a maximum 8 Amp current limiting circuit or a maximum  
5 Amp fuse or positive temperature coefficient (PTC) resistor. This Intel server board has PTCs on  
all external ports that provide DC power externally.  
In the United States  
A certification mark by a Nationally Recognized Testing Laboratory (NRTL) such as UL, CSA, or  
ETL signifies compliance with safety requirements. External wiring must be UL Listed and  
suitable for the intended use. Internal wiring must be UL Listed or Recognized and rated for  
applicable voltages and temperatures. The FCC mark (Class A for commercial or industrial only or  
Class B for residential) signifies compliance with electromagnetic interference requirements.  
In Canada  
A nationally recognized certification mark such as CSA or cUL signifies compliance with safety  
requirements. No regulatory assessment is necessary for low voltage DC wiring used internally or  
wiring used externally when provided with appropriate overcurrent protection. Appropriate  
protection is provided by a maximum 8 Amp current limiting circuit or a maximum approved  
5 Amp fuse or positive temperature coefficient (PTC) resistor. This server board has PTCs on all  
external ports that provide DC power externally.  
Prevent Power Supply Overload  
Do not overload the power supply output. To avoid overloading the power supply, make sure that  
the calculated total current load of all the modules within the computer is less than the maximum  
output current rating of the power supply. If you do not do this, the power supply may overheat,  
catch fire, or damage the insulation that separates hazardous AC line circuitry from low voltage  
user accessible circuitry and result in a shock hazard. If the load drawn by a module cannot be  
determined by the markings and instructions supplied with the module, contact the module  
supplier’s technical support.  
L440GX+ Server Board Product Guide  
107  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Place Battery Marking on Computer  
There is insufficient space on this server board to provide instructions for replacing and disposing  
of the battery. The following warning must be placed permanently and legibly on the host  
computer as near as possible to the battery.  
WARNING  
Danger of explosion if battery is incorrectly replaced.  
Replace with only the same or equivalent type recommended by the  
manufacturer. Dispose of used batteries according to the  
manufacturer’s instructions.  
Use Only for Intended Applications  
This product was evaluated for use in ITE computers that will be installed in offices, schools,  
computer rooms and similar locations. The suitability of this product for other product categories  
other than ITE applications, (such as medical, industrial, alarm systems, and test equipment) may  
require further evaluation.  
Installation Precautions  
When you install and test the server board, observe all warnings and cautions in the installation  
instructions.  
To avoid injury, be careful of:  
·
·
·
·
·
Sharp pins on connectors  
Sharp pins on printed circuit assemblies  
Rough edges and sharp corners on the chassis  
Hot components (like processors, voltage regulators, and heat sinks)  
Damage to wires that could cause a short circuit  
Observe all warnings and cautions that instruct you to refer computer servicing to qualified  
technical personnel.  
WARNING  
Do not open the power supply. Risk of electric shock and burns from  
high voltage and rapid overheating. Refer servicing of the power supply  
to qualified technical personnel.  
108  
Regulatory and Integration Information  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7 Equipment Log and Power Consumption  
Worksheets  
Equipment Log  
Use the blank equipment log provided here to record information about your system. You will  
need some of this information when you run the SSU.  
Manufacturer Name and  
Item  
Model Number  
Serial Number  
Date Installed  
System  
Server board  
Primary Processor speed  
and cache  
Secondary Processor speed  
and cache  
Video display  
Keyboard  
Mouse  
Diskette drive A  
Diskette drive B  
Tape drive  
CD-ROM drive  
Hard disk drive 1  
Hard disk drive 2  
Hard disk drive 3  
Hard disk drive 4  
Hard disk drive 5  
continued  
109  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Equipment Log (continued)  
Manufacturer Name and  
Model Number  
Item  
Serial Number  
Date Installed  
110  
Equipment Log and Power Consumption Worksheets  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Current Usage  
As an overall current usage limitation on the power supply, do not exceed a combined power output  
of 167 watts for the +5 and +3.3 volt outputs.  
The ISA slots on the server board are rated at a maximum of 4.5 amperes per slot. The ISA  
specification recommends supporting an average of 2.0 amperes per slot. The average current  
usage should not exceed 3.0 amperes per slot; that is, 15 watts.  
The PCI slots on the server board are rated at a maximum of 5 amperes per slot. The maximum  
power allowed for each slot is 20 watts at +5 volts. The average current usage per slot should not  
exceed 3.0 amperes per slot; that is, 15 watts.  
The cooling efficiency varies per slot; therefore, ensure that adequate cooling is available in the  
target slot—especially in an expansion slot drawing more than 2.0 amperes.  
Calculating Power Consumption  
The total combined wattage for the system configuration must be less than the output of your power  
supply. Use the two worksheets in this section to calculate the power used by your server boards.  
For current and voltage requirements of add-in boards and peripherals, see your vendor documents.  
L440GX+ Server Board Product Guide  
111  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Worksheet, Calculating DC Power Usage  
1. List the current for each board and device in the appropriate voltage level column.  
2. Add the currents in each column. Then go to the next worksheet.  
Table 14. Power Usage Worksheet 1  
Current (maximum) at voltage level:  
Device  
+3.3 V  
1.0 A  
+5 V  
–5 V  
+12 V  
1.1 A  
–12 V  
0.4 A  
Server board  
8.0 A  
0.1 A  
Primary Processor  
Secondary Processor (if present)  
Terminator card, if no second  
processor  
1.6 A  
1.8 A  
Memory (four 128 MB DIMMs)  
PCI slot 1  
0.3 A  
PCI slot 2  
PCI slot 3  
PCI slot 4  
PCI slot 5  
PCI slot 6  
ISA slot 1  
1st 3.5-inch hard disk drive  
2nd 3.5-inch hard disk drive  
3rd 3.5-inch hard disk drive  
4th 3.5-inch hard disk drive  
5th 3.5-inch hard disk drive  
6th 3.5-inch hard disk drive  
7th 3.5-inch hard disk drive  
3.5-inch diskette drive  
CD-ROM drive  
Cooling fan 1  
Cooling fan 1  
Total Current  
112  
Equipment Log and Power Consumption Worksheets  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Worksheet, Total Combined Power Used by the System  
1. From the previous worksheet, enter the total current for each column.  
2. Multiply the voltage by the total current to get the total wattage for each voltage level.  
3. Add the total wattage for each voltage level to arrive at a total combined power usage on the  
power supply.  
Table 15. Power Usage Worksheet 2  
Voltage level and total current  
(V X A = W)  
Total Watts  
for each voltage level  
(+3.3 V) X (______ A)  
(+5 V) X (______ A)  
(–5 V) X (______ A)  
(+12 V) X (______ A)  
(–12 V) X (______ A)  
Total Combined Wattage  
________ W  
________ W  
________ W  
________ W  
________ W  
________ W  
L440GX+ Server Board Product Guide  
113  
Download from Www.Somanuals.com. All Manuals Search And Download.  
114  
Equipment Log and Power Consumption Worksheets  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
DIMM types, matching, 24  
DIMMs, use extreme care when  
installing, 24  
ESD protection, 22, 23  
leave boot block protect jumper at  
default, 102  
A
Add-in boards  
IDE bus slots, 12  
ISA, 51  
ISA slots, 12  
PCI, 51  
selecting correct heat sink, 26  
selecting correct processor, 26  
administrative password, 17  
limiting access to SCU, 19  
Advanced Menu, configuring in Setup, 40  
audible beep error codes, 34  
CFG files, 51  
chassis intrusion detection default jumper, 103  
CMOS  
clear to reconfigure diskette drive, 35  
retaining settings, 101  
B
configuration, limiting access to system with  
administrative password, 19  
Back Panel Connectors, 8  
battery  
configuring server board jumpers  
boot block protect, 102  
chassis intrusion detection, 103  
FRB timer, enabling or disabling, 103  
general procedure to change, 100  
location on server board, 99  
retaining CMOS settings, 101  
retaining stored password, 101  
configuring system  
disposing of safely, 30  
installing, 31  
removing, 30  
beep codes, 34  
BIOS  
changing the language, 81  
recovering, 81  
upgrading, 79  
BIOS update utility, 33  
BMC, 15  
SCU, 33  
Setup, 33  
boot block write protect default jumper, 102  
connector  
Boot Device Priority menu, configuring,  
Setup, 49  
fan, 98  
front panel, 97  
locations on server board, 96  
Boot menu, configuring, Setup, 48  
boot sequence  
Console Redirection menu, configuring in  
Setup, 46, 47, 48  
booting without keyboard, 20  
setting in Setup, 20  
controller  
bootable media, required by POST, 34  
booting cold, 85  
baseboard management (BMC), 15  
diskette (floppy), 13  
IDE, 13  
keyboard/mouse, 14  
network, 7, 14  
bus termination requirements, SCSI  
devices, 13  
C
SCSI, 13  
video, 7, 13  
cables, IDE bus length limit, 14  
cooling, heat sink for processor, 26  
current ratings for add-in board slots, 111  
Caution  
avoid damaging jumpers when  
changing, 22  
avoid touching processor pins, 26  
L440GX+ Server Board Product Guide  
115  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Firmware Update Utility, 82  
form factor, 7  
D
diagnostics, preparing system for testing, 88  
FRB timer enable default jumper, 103  
front panel control board  
connector on server board, 97  
FRUSDR load utility, 33  
when to run, 75  
DIMM (memory)  
installing, 24  
removing, 25  
diskette  
drive controller, 13  
FRUSDR Load Utility, 75  
enabling/disabling floppy writes, 19  
no booting in secure mode without  
password, 19  
reconfiguring if cannot enter Setup, 35  
running SCU from, 33, 34  
G - H  
gasket, EMI protection at I/O connectors, 23  
Hard Drive menu, configuring, Setup, 49, 50  
heat sink, fan, 26  
E
hot key option, quick reference, 33  
Emergency Management Port  
FRU viewer, 74  
main console window, 67  
phonebook, 71  
I
I/O  
ISA expansion slots, 7  
PCI expansion slots, 7  
ports provided, 7  
requirements, 65  
SDR viewer, 73  
server control operations, 68  
Emergency Management Port Console, 16, 62  
EMI, gasket for I/O connectors, 23  
I2C bus for monitoring status, 15  
IDE  
bus length limit, 14  
controller, 13  
feature summary, 12  
primary, master and slave, configuring,  
Setup, 38  
EMP. See Emergency Management Port  
Console. See Emergency Management Port  
Console  
equipment log, 109  
error  
Integrated Peripheral Configuration menu,  
configuring in Setup, 41  
codes and messages, 94  
messages, 34, 94  
intrusion detection, 15, 17  
ISA  
ESD  
add-in boards, 21  
embedded device support, 7  
expansion slots, 7  
feature summary, 12  
slot current ratings, 111  
avoiding damage to product, 21  
do not touch processor pins, 26  
server board sensitive to, 22, 23  
Exit menu, configuring, Setup, 50  
expanded video memory, 13  
Extended RAM Step menu, 49  
J - K - L  
jumpers, do not damage when changing, 22  
keyboard  
F
compatibility, 14  
fan  
features, configuring, Setup, 39  
lockout timer, seting in SCU, 14  
language, changing in BIOS, 81  
lithium backup battery  
disposing of safely, 30  
installing, 31  
connectors on server board, 98  
heat sink, disconnecting, 26  
feature summary  
back panel connectors, 8  
board, 7  
Firmware update utility, 33  
removing, 30  
116  
Index  
Download from Www.Somanuals.com. All Manuals Search And Download.  
POST  
bootable media required, 34  
M - N  
Main power supply, connector, 98  
countdown codes, 94  
error codes and messages, 94  
error messages, 34  
memory  
amount tested, POST, 34  
capacity, 7  
DIMM requirements, 11  
DIMM size, 10  
memory, amount tested, 34  
power on/off, locking on/off switch, Setup, 19  
power supply  
expansion, 10  
calculating power usage, 111  
current usage, 111  
main connector pins, 98  
monitoring power state, 15  
worksheet, calculating DC power, 112  
installing DIMM, 24  
removing DIMM, 25  
video amount, 7  
video size, 13  
what type to install, 7  
messages, error and informational, 94  
monitoring server status, 15  
mouse  
compatibility, 14  
inactivity timer, 14  
network, controller, 7, 14  
problems  
after running new application software, 86  
after system has been running  
correctly, 87  
application software, 93  
bootable CD-ROM not detected, 93  
cannot connect to network server, 92  
CD-ROM drive activity light, 91  
confirm OS loading, 88  
diskette drive light, 91  
hard drive light, 91  
initial system startup, 85  
network, 92  
no characters on screen, 89  
PCI installation tips, 93  
P
password, 17  
administrative, 17  
administrator, 18  
entering to unblank screen, 19  
retaining at system reset, 101  
user, 17  
power light, 89  
using to reactivate keyboard/mouse, 19  
using to reactivate keyboard/mouse, 14  
PCI  
preparing system for diagnostic testing, 88  
random error in data files, 87  
screen characters incorrect, 90  
system cooling fans do not rotate, 90  
system lights, 88  
embedded devices, 7  
expansion slots, 7  
slot current ratings, 111  
processor, 26  
PCI Configuration Menu, configuring in  
Setup, 40  
installing, 28  
removing, 26  
selecting the correct processor, 26  
use grounded, static free surface, 26  
processor description, 10  
PCI Device, Embedded SCSI menu,  
configuring in Setup, 40, 42  
PCI Device, Slot 1 - Slot 4 menu, configuring  
in Setup, 41  
PEP. See Platform Event Paging  
PEP Filter Submenu, 48  
R
real time clock, running SCU to configure  
settings, 31  
PEP Management Submenu, 47  
Platform Event Paging, 17, 61  
recovery boot jumper, retaining settings, 102  
removing termination board, 28  
reset system, 33, 85  
L440GX+ Server Board Product Guide  
117  
Download from Www.Somanuals.com. All Manuals Search And Download.  
server management  
BMC, 15  
features, 15  
intrusion detection, 17  
Server Management, 7  
S
SCI files, 51  
SCSI, bus termination requirements, 13  
SCSI controller, 13  
SCU  
Server Management Information menu,  
configuring in Setup, 45  
administrative password limits access  
to, 19  
changing configuration, 33  
diskette drive required to run SCU, 33  
inactivity (lockout) timer, 14  
software locking feature, 17  
Server menu, configuring in Setup, 44  
Setup  
Advanced menu, 40  
Boot Device Priority menu, 49  
Boot menu, 48  
cannot enter, need to reconfigure  
diskette, 35  
changing configuration, 33  
Console Redirection menu, 46, 47, 48  
description, 36  
secure mode, 18  
affects boot sequence, 20  
enter by setting passwords, 19  
locking reset and power on/off  
switches, 19  
no booting from diskette without  
password, 19  
Exit menu, 50  
Hard Drive menu, 49, 50  
Integrated Peripheral Configuration  
menu, 41  
keyboard features menu, 39  
locking reset and power on/off  
switches, 19  
using hot keys to enter, 33  
security, 17, 19  
alarm switches, 17  
boot sequence, 20  
enabling/disabling floppy writes, 19  
locking mouse, keyboard with timer,  
14, 19  
locking reset and power on/off switches,  
Setup, 19  
Main menu, 37  
PCI Configuration menu, 40  
PCI Device, Embedded SCSI menu  
contents, 40, 42  
PCI Device, Slot 1 - Slot 4 menu, 41  
primary IDE master and slave menu, 38  
recording settings, 35  
security menu contents, 43  
Server Management Information menu  
contents, 45  
password, 19  
secure mode, 19  
secure mode, setting in SCU, 18  
software lock, SCU, 17  
unattended start, 20  
using hot key combination, 33  
video blanking, 19  
server menu contents, 44  
Security menu, configuring, Setup, 43  
server board  
soft boot, 85  
SSU. See system setup utility  
boot block protect, jumper, 102  
chassis intrusion detection, jumper, 103  
CMOS settings, jumper, 101  
component locations, figure, 9  
configuration jumpers, 100  
configurations, 99  
switches  
alarm, 17  
locking reset and power on/off, Setup, 19  
Switches  
DC power, 85  
reset, 85  
fan connectors, 98  
System Configuration Utility. See SCU  
FRB timer enable, jumper, 103  
front panel connector, 97  
installing, 22  
password jumper, 101  
recovery boot settings, jumper, 102  
removing, 23  
118  
Index  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System setup utility  
CFG files, 51  
V
video  
customizing, 54  
defining an ISA card, 55  
exiting, 60  
blanking for security, 19  
controller, 13  
expansion, 13  
memory, 7  
launching a task, 54  
location, 50  
resolutions supported, 13  
video controller, 7  
video memory, 13  
removing an ISA card, 56  
running, 52  
locally, 52  
remotely, 52  
W
Warning  
SCI files, 51  
when to run, 51  
components may be hot, 26  
T - U  
termination board, removing, 28  
dispose of lithium battery safely, 30  
ESD can damage product, 21  
worksheet, calculating DC power usage, 112  
write protect boot block, jumper, 102  
write to diskette, disabling, 19  
timer  
keyboard or mouse inactive, 14  
lockout (inactivity), setting in SCU, 14  
upgrade Flash utility, 79  
user password, 17  
limit access to using system, 20  
utilities  
BIOS update, 33  
Emergency Management Port Console,  
16, 62  
Firmware update, 33, 82  
FRUSDR load, 33  
SCSI, 33  
SCU, 33  
Setup, 33, 35  
Utilities, FRUSDR load utility, 75  
L440GX+ Server Board Product Guide  
119  
Download from Www.Somanuals.com. All Manuals Search And Download.  
120  
Index  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Ingersoll Rand Impact Driver 3940 User Manual
Insignia Telephone NS HTMC01 B User Manual
JAI Security Camera TM TMC 4200CL User Manual
JBL Speaker System SCS2005 230 User Manual
JVC Car Stereo System GET0647 004A User Manual
JVC VCR HR J231MS User Manual
Kenwood Car Stereo System TH 21A User Manual
Keys Fitness Treadmill HT901 User Manual
KitchenAid Washer KAWE760W User Manual
Kreisen CRT Television KR 270T User Manual