Intel MB440LX
System Installation Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Copyright © 1996, 1997 Intel Corporation. All rights reserved. No part of this
document may be copied or reproduced in any form, or by any means, without
prior written consent of Intel.
Intel Corporation (Intel) makes no warranty of any kind with regard to this material,
including, but not limited to, the implied warranties of merchantability and fitness
for a particular purpose. Intel assumes no responsibility for any errors that may
appear in this document. Intel makes no commitment to update nor to keep current
the information contained in this document.
✝ Third party trademarks are the property of their respective owners.
printed on
recycled paper
2
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety Guidelines
B
,
:
EFORE YOU REMOVE A SERVER COVER OBSERVE THESE GUIDELINES
1. Turn off all peripheral devices connected to the server.
2. Turn off the server using the power button on the front panel of the
server, and unplug the alternating current (AC) power cord from each
power supply.
3. Label and disconnect all peripheral cables attached to the I/ O panel on
the back of the server.
4. Provide some electrostatic discharge (ESD) protection by wearing an
antistatic wrist strap attached to chassis ground of the server—any
unpainted metal surface—when handling components.
Warnings and Cautions
These warnings and cautions apply whenever you remove the side cover of
the server to access components inside the server. Integration of the server
should be done by technically qualified personnel.
!
▲
WARNINGS
SERVER POWER ON/OFF: The power button on the front
panel of the server does not turn off the AC power. To
remove AC power from the server, you must unplug each
AC power cord from each power supply or wall outlet.
HAZARDOUS CONDITIONS, POWER SUPPLY AND POWER SHARE
BACKPLANE Hazardous voltage, current, and energy levels
:
are present inside the power supply and the power share
backplane. There are no user serviceable parts inside
them; servicing should be done only by technically
qualified personnel.
M440LX Server System Product Guide
3
Download from Www.Somanuals.com. All Manuals Search And Download.
HAZARDOUS CONDITIONS, DEVICES AND CABLES: Hazardous
electrical conditions may be present on power, telephone,
and communication cables. Turn off the server and
disconnect telecommunications systems, networks,
modems, and each power cord attached to the server
before opening it. Otherwise, personal injury or
equipment damage can result.
CAUTIONS
!
▲
▲
ELECTROSTATIC DISCHARGE (ESD) AND ESD PROTECTION:
ESD can damage disk drives, add-in boards, and other
components. We recommend doing all procedures in this
manual only at an ESD workstation. If one is not available,
you can provide some ESD protection by wearing an
antistatic wrist strap attached to chassis ground of the
server—any unpainted metal surface—when handling
components.
ANDLING BOARDS AND MODULES: Boards and modules can
H
be extremely sensitive to ESD and always require careful
handling. After removing a board or module from its
protective wrapper or from the server, place it
component-side up on a nonconductive, static-free surface.
If you place the system board on a conductive surface, the
battery leads may short out. If they do, this will result in a
loss of CMOS data and will drain the battery. Do not slide
a board or module over any surface.
COOLING AND AIRFLOW: Operating the server with the covers
removed can damage the server components. For proper
cooling and airflow, always replace the covers before
turning on the server.
■ ■ ■
■ ■ ■
4
Safety Guidelines
Download from Www.Somanuals.com. All Manuals Search And Download.
Preface
Notational Conventions
The notational conventions listed below are used throughout this manual.
<F1>
A letter, number, symbol, or word enclosed in < > represents
a key on your keyboard. For example, the instruction "press
<F1>" means press the key labeled "F1" on your keyboard.
<Enter>
<x + y>
Other manuals refer to <Enter> as RETURN, CARRIAGE
RETURN, <CR>, or use an arrow. All of these terms are
interchangeable.
Two or three key names, separated by plus signs, indicate
multiple-key entries. For example, <Ctrl + Alt + Del> means
hold down <Ctrl> and <Alt> and press <Del>.
Three squares mark the end of a chapter.
■ ■ ■
■ ■ ■
The special notices listed below are used throughout this manual to
emphasize specific information:
!
▲
WARNING
WARNING indicates a hazard that can cause personal
injury or equipment damage if the hazard is not avoided.
CAUTION
!
▲
▲
CAUTION indicates a hazard that might cause personal
injury, damage to hardware, or software if the hazard is not
avoided.
Note
✏
Notes provide information and may be used to emphasize a
recommended sequence of steps.
■ ■ ■
■ ■ ■
M440LX Server System Product Guide
5
Download from Www.Somanuals.com. All Manuals Search And Download.
1-6
Your Chapter Title Goes Here
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
1
Server Description
System Features .......................................................................................
Chassis ......................................................................................................
Controls and Indicators...........................................................................
System Security ........................................................................................
Password Protection .........................................................................
Secure Boot Mode .............................................................................
Boot Sequence Control......................................................................
Boot Without Keyboard ....................................................................
Power and Reset Button Lock ..........................................................
Diskette Write Protection .................................................................
Video Blanking ..................................................................................
Power System ...........................................................................................
Server Cooling..........................................................................................
Peripheral Drive Bays..............................................................................
3.5-inch User Accessible Diskette Drive Bay ..................................
5.25-inch User Accessible Drive Bays..............................................
3.5-inch Hot-docking Drive Bays.....................................................
Onboard RAID .........................................................................................
Server System Board................................................................................
ISA Expansion Slots ..........................................................................
PCI Expansion Slots ..........................................................................
PCI Video Controller ........................................................................
SCSI Controllers ................................................................................
IDE Controller ...................................................................................
Server Management ..........................................................................
Pentium II Processor..............................................................................
Memory Module ......................................................................................
System Configuration Options ...............................................................
Base System Configuration ..............................................................
System Upgrade Options .................................................................
18
20
23
25
27
27
27
27
27
28
28
28
28
29
29
29
29
30
30
30
31
31
34
34
35
36
36
37
37
38
M440LX Server System Product Guide
7
Download from Www.Somanuals.com. All Manuals Search And Download.
2
Installing The System
Selecting a Site ..........................................................................................
Physical Specifications .............................................................................
Environmental Specifications..................................................................
After Unpacking the Server.....................................................................
Installing the Pentium II Processor .........................................................
Installing the Memory Module ...............................................................
Connecting Peripheral Devices ...............................................................
Warnings and Cautions ....................................................................
Keyboard ............................................................................................
Mouse.................................................................................................
Monitor ..............................................................................................
Other Devices ....................................................................................
Checking the Power Cord(s) ...................................................................
Turning on Your Server...........................................................................
Power-on Self-Test ............................................................................
Creating Installation Software Diskettes................................................
40
41
41
42
42
42
43
43
43
43
43
43
45
45
46
47
3
Configuring The System
Configuration Utilities.............................................................................
Power-on Self-Test ...................................................................................
When to Use the System Configuration Utility .....................................
How to start the SCU...............................................................................
System Board Settings Field Descriptions..............................................
Systems Group ..................................................................................
Memory Subsystem Group...............................................................
On-Board Disk Controllers...............................................................
Onboard Communications Devices.................................................
Floppy Drive Subsystems Group .....................................................
IDE Subsystem Group ......................................................................
Multiboot Group ...............................................................................
KB and Mouse Subsystem Group ....................................................
Console Redirection ..........................................................................
Security Subsystem ...........................................................................
SCSI ROM BIOS Options Group ......................................................
Management Subsystem Group .......................................................
When to Run the BIOS Setup Utility ......................................................
Running the Setup Utility........................................................................
Main Menu.........................................................................................
Advanced Menu ................................................................................
Security Menu....................................................................................
49
50
51
52
53
53
53
54
54
55
55
57
57
57
58
59
59
60
60
62
65
70
8
Contents
Download from Www.Somanuals.com. All Manuals Search And Download.
Server Menu ......................................................................................
Boot Menu .........................................................................................
Exit Menu...........................................................................................
Using the Symbios SCSI Utility ..............................................................
Running the SCSI Utility ..................................................................
Hot Keys ...................................................................................................
Installing Video Drivers ..........................................................................
Installing SCSI Drivers ............................................................................
72
73
75
76
76
76
77
77
4
Working Inside Your System
Preparation ...............................................................................................
Warnings and Cautions ....................................................................
Tools and Supplies You Need ..........................................................
Equipment Log..................................................................................
Covers .......................................................................................................
Removing a Side Cover ....................................................................
Replacing a Side Cover .....................................................................
Removing the Top Cover .................................................................
Replacing the Top Cover ..................................................................
Removing the Plastic Front Cover ...................................................
Replacing the Plastic Front Cover....................................................
Removing the Snap-in Plastic Peripheral Bay Cover .....................
Replacing the Snap-in Plastic Peripheral Bay Cover ......................
Board Set...................................................................................................
Removing the Termination Board ...................................................
Installing a Voltage Regulator Module............................................
Installing a Pentium II Processor .....................................................
Removing a Pentium II Processor....................................................
Installing the Memory Module ........................................................
Removing the Memory Module.......................................................
Installing the RPX Module ...............................................................
Removing the RPX Module..............................................................
Add-in Boards..........................................................................................
Installing an Add-in Board ...............................................................
Removing an Add-in Board .............................................................
Diskette Drive ..........................................................................................
Removing the Diskette Drive...........................................................
Installing a Diskette Drive................................................................
5.25-inch Peripherals................................................................................
Installing a 5.25-inch Peripheral Device ..........................................
Removing a 5.25-inch Peripheral Device.........................................
79
79
79
79
80
80
81
82
83
84
84
86
87
88
88
89
91
92
92
94
94
96
97
98
102
103
103
105
106
107
111
M440LX Server System Product Guide
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Back-up Battery ........................................................................................
Replacing the Back-up Battery .........................................................
Front Panel Board ....................................................................................
Removing the Front Panel Board .....................................................
Replacing the Front Panel Board......................................................
Fans ...........................................................................................................
Removing a Front Panel Fan ............................................................
Replacing a Front Panel Fan .............................................................
Removing the Fan Below the Top Power Supply ...........................
Replacing the Fan Below the Power Supply ...................................
Power System ...........................................................................................
Removing a Power Supply ...............................................................
Replacing a Power Supply................................................................
Power Share Backplane ...........................................................................
Removing the Power Share Backplane ............................................
Installing the Power Share Backplane..............................................
SCSI Hot-docking Backplane ..................................................................
Removing a Hot-docking Backplane ...............................................
Installing a Hot-docking Backplane.................................................
112
113
115
115
115
117
117
120
120
123
124
124
125
126
126
129
130
130
130
5
SCSI Backplane and Drives: Hot-swapping and
Configuring
Warnings and Cautions ...........................................................................
Tools and Supplies You Need .................................................................
Hot-docking Bays.....................................................................................
SCSI Hard Disk Drive..............................................................................
Mounting a SCSI SCA Hard Disk Drive in a Plastic Carrier .........
Installing a SCSI SCA Hard Disk Drive in a Hot-docking Bay .....
Hot-swapping a SCSI SCA Hard Disk Drive..................................
SCSI Hot-docking Backplane ..................................................................
Configuration Options ......................................................................
SCSI Hot-docking Backplane Connectors ..............................................
Wide/ Fast SCSI 16-Bit Connector....................................................
Wide/ Fast SCA2 SCSI 16-Bit Connectors .......................................
Power Connectors .............................................................................
Fan Connector....................................................................................
Front Panel Connector ......................................................................
133
133
133
134
135
136
138
139
139
143
143
144
145
145
146
10
Contents
Download from Www.Somanuals.com. All Manuals Search And Download.
6
Server Resources
Warnings and Cautions...........................................................................
Tools and Supplies You Need .................................................................
Memory Module Resources ....................................................................
Memory Regions ...............................................................................
ECC Memory.....................................................................................
System Board Resources .........................................................................
Video Memory DRAM .....................................................................
I/ O Addresses and Resources .........................................................
Interrupts ...........................................................................................
Flash ROM .........................................................................................
147
147
148
150
151
157
157
159
161
162
7
Power System
Power System Configurations ................................................................
Power System Control Signals................................................................
Power Enable/ Disable (PON)..........................................................
Remote Sense Connections...............................................................
Load Share Connection.....................................................................
Output Power Connections..............................................................
Power Good Circuit ..........................................................................
VA Monitor Circuit...........................................................................
I²C Communication Circuit..............................................................
System Current Monitor...................................................................
Power Supply FAULT ......................................................................
Power Supply Presence DETECT ....................................................
Power Share Backplane Interconnections ..............................................
Power Supply to Powershare Board Connections..........................
Backplane to System Board Power Interface ..................................
Backplane to Peripheral Interface ....................................................
Backplane to System Board Control Connections ..........................
Power Supply Input Voltages .................................................................
Power Supply Output Voltages ..............................................................
Server Current Usage ..............................................................................
Calculating Power Usage ........................................................................
163
165
165
165
165
165
166
166
166
167
167
167
168
168
169
169
170
170
171
172
174
M440LX Server System Product Guide
11
Download from Www.Somanuals.com. All Manuals Search And Download.
8
System Board Jumpers
Warnings and Cautions ...........................................................................
Tools and Supplies You Need .................................................................
Configuration Jumpers ............................................................................
Chassis Intrusion Detection..............................................................
Fault Resilient Booting (FRB) ...........................................................
Flash Memory....................................................................................
CPU Speed .........................................................................................
Boot Option........................................................................................
Password ............................................................................................
CMOS.................................................................................................
177
177
178
179
180
180
181
182
183
184
9
I/O Ports and Connectors
Signal States..............................................................................................
Server System Board ................................................................................
System Board Layout........................................................................
System Board Connector Locations.................................................
Power Connector...............................................................................
Auxiliary Power Connector..............................................................
I2C Connector.....................................................................................
Control Panel Connector ..................................................................
Diskette Drive Port............................................................................
Wide/ Fast 16-Bit SCSI Connector....................................................
IDE Connector ...................................................................................
Fan Connectors..................................................................................
Blower Connectors ............................................................................
SCSI Controller Activity LED Connector........................................
Server Management Connector........................................................
ISA Connectors..................................................................................
PCI Connectors..................................................................................
Keyboard and Mouse Connectors....................................................
Parallel Port .......................................................................................
VGA Video Port ................................................................................
Serial Ports .........................................................................................
185
185
186
187
188
188
188
189
189
190
191
192
192
192
193
194
195
196
197
198
199
12
Contents
Download from Www.Somanuals.com. All Manuals Search And Download.
10
Solving Problems
Resetting the Server .................................................................................
Initial System Startup ..............................................................................
Checklist.............................................................................................
Running New Application Software ......................................................
Checklist.............................................................................................
After the System Has Been Running Correctly .....................................
Checklist.............................................................................................
Additional Troubleshooting Procedures................................................
Preparing the System for Diagnostic Testing..................................
Monitoring POST ..............................................................................
Verifying Proper Operation of Key System Lights.........................
Confirming Loading of the Operating System ...............................
Specific Problems and Corrective Actions.............................................
Power Light Does Not Light ............................................................
System Cooling Fans Do Not Rotate Properly................................
No Characters Appear on Screen ....................................................
Characters Are Distorted or Incorrect.............................................
Incorrect or no Beep Codes ..............................................................
Diskette Drive Activity Light Does Not Light................................
Hard Disk Drive Activity Light Does Not Light............................
Problems With Application Software..............................................
Error and Informational Messages .........................................................
POST Beep Codes ....................................................................................
POST Codes and Countdown Codes .....................................................
Normal Port-80 Codes ......................................................................
POST Error Codes and Messages ....................................................
201
202
202
203
203
204
204
205
205
206
206
206
207
207
208
209
209
210
210
211
212
213
213
214
214
219
A
B
Regulatory Specifications
Declaration of the Manufacturer or Importer........................................
Safety Compliance ...................................................................................
Electromagnetic Compatibility (EMC)...................................................
CE Mark .............................................................................................
Electromagnetic Compatibility Notice (USA).................................
Electromagnetic Compatibility Notices (International) .................
225
225
226
226
226
228
Equipment Log
Equipment Log.........................................................................................
230
M440LX Server System Product Guide
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Tables
1-1.
1-2.
6-1.
6-2.
7-1.
7-2.
8-1.
Standard VGA Modes .............................................................................
32
33
Extended VGA Modes.............................................................................
ECC Memory Banks.................................................................................
Sample DIMM Size Combinations..........................................................
Total Combined Power Used by Your System ......................................
Worksheet for Calculating DC Power Usage.........................................
System Board Jumpers.............................................................................
151
151
174
175
179
213
214
219
10-1. POST Beep Codes.....................................................................................
10-2. Port-80 Codes ...........................................................................................
10-3. POST Error Codes and Messages ...........................................................
Figures
1-1.
1-2.
1-3.
1-4.
2-1.
2-2.
4-1.
4-2.
4-3.
4-4.
4-5.
4-6.
4-7.
4-8.
4-9.
Server ........................................................................................................
Back/ Right Side View..............................................................................
Controls and Indicators ...........................................................................
Security Padlocks .....................................................................................
Server I/ O Panel ......................................................................................
Power and Reset Buttons.........................................................................
Side Covers...............................................................................................
Top Cover .................................................................................................
Plastic Front Cover...................................................................................
Snap-in Plastic Peripheral Bay Cover .....................................................
Removing a Termination Board ..............................................................
Installing a Voltage Regulator Module...................................................
Installing a Pentium II Processor ............................................................
Installing the Memory Module ...............................................................
Installing the RPX Module ......................................................................
21
22
24
26
44
46
81
83
85
86
89
90
91
93
95
4-10. Expansion Slot Cover...............................................................................
4-11. Installing an ISA Add-in Board, Component-side Up ..........................
4-12. Installing a PCI Add-in Board, Component-side Down .......................
4-13. Removing the Diskette Drive..................................................................
4-14. Diskette Drive and Carrier Assembly ....................................................
4-15. Filler Panels...............................................................................................
4-16. Removing the EMI Shield ........................................................................
4-17. Snap-in Plastic Slide Rails........................................................................
4-18. Installing a 5.25-inch Peripheral Device .................................................
4-19. Lithium Back-up Battery .........................................................................
98
100
101
104
105
107
108
109
110
114
116
4-20.
Removing the Front Panel Board ...........................................................
14
Contents
Download from Www.Somanuals.com. All Manuals Search And Download.
4-21. Front Panel Fans.......................................................................................
4-22. Front Fan Assembly .................................................................................
4-23. Fan Below the Top Power Supply ..........................................................
4-24. Rear Fan Assembly ..................................................................................
4-25. Removing a Power Supply......................................................................
4-26. Removing the Power Share Backplane...................................................
4-27. Power Share Backplane Connectors .......................................................
4-28. Removing a Hot-docking Backplane......................................................
118
119
121
122
125
127
128
131
135
137
142
149
153
154
156
158
178
186
5-1.
5-2.
5-3.
6-1.
6-2.
6-3.
6-4.
6-5.
8-1.
9-1.
Hard Disk Drive and Plastic Carrier ......................................................
Installing a Hard Disk Drive...................................................................
SCSI Backplane.........................................................................................
Memory Module ......................................................................................
DIMM Orientation ...................................................................................
Properly Seated DIMM............................................................................
Removing ECC Memory DIMMs ...........................................................
Video Memory DRAM ............................................................................
System Board Jumpers ............................................................................
System Board Layout...............................................................................
■ ■ ■
■ ■ ■
M440LX Server System Product Guide
15
Download from Www.Somanuals.com. All Manuals Search And Download.
16
Contents
Download from Www.Somanuals.com. All Manuals Search And Download.
Server Description 1
Your system supports symmetrical multiprocessing (SMP) and a variety of
operating systems. The server comes with both PCI and ISA buses, one
narrow and two wide SCSI channels, and onboard video. The server board
set consists of the following:
•
System board with seven PCI expansion slots, three ISA expansion
slots, and several embedded controller devices (PCI video, Dual Ultra
SCSI, Narrow SCSI, and IDE)
•
•
One or two Pentium II processors
Memory module with either eight 3.3 V EDO DIMM sockets for up to
1 GB of memory, or four SDRAM DIMM sockets for 512 MB of memory
•
RPX module with one SIMM† socket for RAID applications
The chassis contains a 3.5-inch diskette drive, a CD-ROM drive, and,
depending on the system configuration, up to three 360 watt power
supplies. Three 5.25-inch peripheral bays can house tape back-up drives,
CD-ROM drives, and other mass storage devices. Any two adjacent
5.25-inch bays can be converted into a single full-height bay. The two
3.5-inch hot-docking peripheral bays, when fully configured with 10 hard
disk drives, provide over 40 GB of storage. The bays allow hot-swapping
drives without shutting down the system.
As your application requirements increase, you can upgrade the system
with
•
•
•
•
More powerful processors
More memory
Other peripheral devices
Add-in I/ O boards
M440LX Server System Product Guide
17
Download from Www.Somanuals.com. All Manuals Search And Download.
System Features
Feature
Description
Processor support
Memory support
Two slots for Pentium II processors
One slot for a memory module that supports up to
1 GB of memory
RAID support
Chassis
One slot for an RPX module that supports I2O and
non-I2O RAID
1.44 MB, 3.5-inch diskette drive in the vertical bay
Three 5.25-inch half-height standard bays; top bay
contains a CD-ROM drive
Two hot-docking bays; each bay has space for five
3.5-inch SCSI hard disk drives
One or two SCSI hot-docking backplanes
Two blowers direct air at the processors
Three integrated power supply fans cool and circulate
air through the power supply side of the system; if it
contains only one or two power supplies, an additional
fan provides cooling and airflow
Power system with
optional redundancy
360 watt power supply, autoranging for 115 or 230
VAC operation, includes an integrated fan for cooling
(system may be configured with up to three power
supplies)
An optional power share board distributes the power
load between the installed power supplies and allows
hot swapping power supplies
Server management
Real-time clock/calendar (RTC)
Front panel controls and indicators (LEDs)
System Configuration Utility (SCU)
Basic Input/Output System (BIOS), Power-on Self
Test, and Setup stored in a flash memory device
18
Chapter 1 Server Description
Download from Www.Somanuals.com. All Manuals Search And Download.
Feature
Description
System I/O
Nine available expansion slots: Six 32-bit PCI, two
16-bit ISA and one common PCI/ISA
Integrated Cirrus Logic CL-GD54M40 SVGA controller
shipped with 512 kilobytes (KB) of video memory
(expandable to 1 MB)
One Symbios SCSI controller for connecting up to
seven 8-bit narrow SCSI devices
Two Symbios wide SCSI controllers for connecting a
mixture of fifteen 8-bit narrow and 16-bit wide SCSI
devices to the controller—maximum of seven 8-bit
narrow SCSI devices
Diskette controller that supports two drives
PCI-enhanced Integrated Drive Electronics (IDE) hard
disk interface that supports two hard disk drives
PS/2†-compatible keyboard/mouse controller
PS/2-compatible keyboard and mouse ports
PS/2-compatible parallel port
Analog VGA†, 15-pin video port
Two 9-pin serial ports
M440LX Server System Product Guide
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Chassis
The electro-galvanized metal chassis minimizes electromagnetic interference
(EMI) and radio frequency interference (RFI). It contains
•
Three power supply bays with up to three 360 watt power supplies,
depending on the configuration
•
•
One vertical bay that contains a diskette drive
Three standard 5.25-in bays for removable media devices (a CD-ROM
drive is in the top bay)
•
Two hot-docking bays; each bay has space for five 1-inch high, 3.5-inch
single connector attachment (SCA) SCSI hard disk drives
•
•
Nine I/ O expansion slot covers
A control panel
20
Chapter 1 Server Description
Download from Www.Somanuals.com. All Manuals Search And Download.
Two spring-loaded captive screws secure the removable metal door behind
the lower plastic front door to the chassis. This door provides proper
air-flow and easy access to the hot-docking bays for hot-swapping hard disk
drives in and out of the system. Both removable side covers are attached to
the chassis with three screws. They provide proper airflow and easy access
to the system board and power supplies. These covers can be secured to the
chassis with padlocks (not provided). Figures 1-1 and 1-2 show the major
system components.
1
2
5
7
6
3 4
OM05788A
Figure 1-1. Server
1
2
3
4
5
6
Processor modules
Memory module
Front panel
SCSI hot-docking bays
5.25-inch external bays
CD-ROM drive
M440LX Server System Product Guide
21
Download from Www.Somanuals.com. All Manuals Search And Download.
9
1
2
8
7
6
5
4
3
OM05792
Figure 1-2. Back/Right Side View
1
2
3
4
5
6
7
8
9
Left side cover
I/O panel
Knock-out slots for external SCSI connectors
Expansion slots
Power supplies
SCSI hot-docking bay
SCSI hot-docking backplane
5.25-inch peripheral bays
3.5-inch diskette drive
22
Chapter 1 Server Description
Download from Www.Somanuals.com. All Manuals Search And Download.
Controls and Indicators
Figure 1-3 shows the location of the system controls and indicators, external
peripheral bays, 3.5-inch diskette drive, and CD-ROM drive.
Front Panel:
•
•
•
Green (HD ACT) LED: when lit, indicates hard drive activity.
Yellow fan failure LED: when flashing, indicates the fan has failed.
Yellow power supply failure LED: when flashing, indicates a power
supply has failed.
•
•
10 yellow hard drive failure LEDs: when lit, indicates a drive failure in
the hot-docking bay.
Green power LED: when lit, indicates the presence of DC power in the
system. The LED goes out when the power is turned off or the power
source is disrupted.
•
•
Power button: when pressed, turns the DC power on or off.
Reset button: when pressed, resets the system and causes POST to run.
Peripherals:
•
•
•
•
Diskette drive activity LED: when lit, indicates the drive is in use.
Diskette drive ejector button: when pressed, ejects the disk.
CD-ROM headphone jack: used to connect headphones or speakers.
CD-ROM volume control: used to adjust the volume of headphones or
speakers.
•
•
CD-ROM open/ close button: used to open and close the CD tray.
CD-ROM activity LED: when lit, indicates the drive is in use.
M440LX Server System Product Guide
23
Download from Www.Somanuals.com. All Manuals Search And Download.
12
13
1
11
10
9
8
7
6
5
4
3
2
OM05260
Figure 1-3. Controls and Indicators
1
2
3
4
5
6
7
8
9
Diskette drive activity LED
Diskette drive ejector button
CD-ROM open/close button
CD-ROM power LED
CD-ROM volume control
CD-ROM headphone jack
Reset button
Power supply failure LED
Fan failure LED
10 Hard drive activity LED
11 Drive failure LEDs for hot-docking bays
12 Power on LED
13 Power button
24
Chapter 1 Server Description
Download from Www.Somanuals.com. All Manuals Search And Download.
System Security
There are several ways to prevent unauthorized entry or use of the system.
Security with padlocks and alarm switches:
•
•
Secure the side covers and the hot-docking bay metal door to the chassis
by inserting padlocks (not provided) through the holes in the metal tabs
protruding through slots in the covers and door.
Activate alarm switches for the side covers and hot-docking bay metal
door. These switches transmit alarm signals to the system board.
Software on the system board intercepts these signals and alerts the user
to unauthorized activity.
Security with the Setup utility:
•
•
Set administrative and user passwords.
Set secure mode to prevent keyboard or mouse input and to prevent use
of the front panel controls.
Security with the System Configuration Utility (SCU):
•
Enable the keyboard lockout timer so that the system requires a
password to reactivate the keyboard and mouse after a specified
time-out period—1 to 128 minutes.
•
•
•
•
•
Set an administrative password.
Set a user password.
Activate the secure mode hot-key.
Disable writing to the diskette drive.
Enable video blanking if using onboard video.
M440LX Server System Product Guide
25
Download from Www.Somanuals.com. All Manuals Search And Download.
OM05793
Figure 1-4. Security Padlocks
26
Chapter 1 Server Description
Download from Www.Somanuals.com. All Manuals Search And Download.
Password Protection
If you set the user password but not the administrative password, the BIOS
requires you to enter the user password before you can boot the system or
run the SCU. If you set both passwords, entering either one lets you boot
the system or enable the keyboard and mouse, but only the administrative
password lets you change the system configuration.
Secure Boot Mode
The secure boot mode allows the system to boot and run the operating
system (OS). However, you cannot use the keyboard or mouse until you
enter the user password.
You can use the SCU to put the system into the secure boot mode. If the
BIOS detects a CD in the CD-ROM drive or a diskette in drive A at boot
time, it prompts you for a password. When you enter the password, the
system boots from the CD-ROM drive or diskette drive and disables the
secure mode.
If there is no CD in the CD-ROM drive or diskette in drive A, the system
boots from drive C and automatically goes into secure mode. All enabled
secure mode features go into effect at boot time.
You can set a hot-key combination to secure the system immediately.
Boot Sequence Control
The BIOS security features determine the boot devices and the boot
sequence. They also control disabling writes to the diskette drive in secure
mode. You can use the SCU to select each boot device. The default boot
sequence is diskette, hard disk, CD-ROM, and Network.
Boot Without Keyboard
The system can boot with or without a keyboard. Before boot, the BIOS
displays a message whether it has detected a keyboard or not. During
POST, the BIOS automatically detects and tests the keyboard if it’s present.
Power and Reset Button Lock
If enabled by the Setup Utility, the power and reset buttons are disabled
when in the secure mode.
M440LX Server System Product Guide
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Diskette Write Protection
If the protection feature is enabled with the SCU, diskette writes are
disabled when the system is in the secure mode. Diskette write protection is
only in effect while the system is in the secure mode. Otherwise, write
protection is disabled.
Video Blanking
If enabled with the setup or SCU, the video screen goes blank when the
system is in secure mode.
Power System
The power system in the server may be configured with one, two, or three
360 watt power supplies.
The 360 watt power supply provides sufficient power for an entry level
server. The power supply accepts these input voltage ranges:
•
•
100-120 VAC at 50/ 60 Hertz (Hz); 7.7 A maximum current
200-240 VAC at 50/ 60 Hz; 4.4 A maximum current
If a single power supply fails in a redundant power system, the yellow
power supply failure LED on the front panel starts flashing. You can swap
out the faulty supply without shutting down the server.
Server Cooling
Two blowers inside the chassis provide cooling for the processors, memory
modules, and add-in boards. Two more fans may be installed for
redundant cooling. If a fan or blower fails, the server management
subsystem notifies the system board and turns on an LED on the front
panel.
A system with only one power supply includes an auxiliary fan to provide
cooling for the hard drives. A system with multiple power supplies
provides enough cooling without an auxiliary fan.
28
Chapter 1 Server Description
Download from Www.Somanuals.com. All Manuals Search And Download.
Peripheral Drive Bays
3.5-inch User Accessible Diskette Drive Bay
The 3.5-inch diskette drive in the vertical 3.5-inch peripheral bay supports
720 KB and 1.44 MB media.
5.25-inch User Accessible Drive Bays
Three 5.25-inch half-height bays provide space for removable media devices
such as tape drives and CD-ROM drives. You can convert any two adjacent
5.25-inch bays to a single full-height bay. We recommend that you do not
use these bays for hard disk drives because they generate EMI, and ESD
susceptibility increases.
3.5-inch Hot-docking Drive Bays
Using industry standard 80-pin SCA connectors, the hot-docking backplane
in the upper bay supports up to five industry standard SCA hard disk
drives. The hot-docking bays accept peripherals that consume up to 11
watts of power and run at a maximum ambient temperature of 55 °C.
You can install an additional hot-docking backplane in the lower
hot-docking bay for five more drives. However, if you do, you must install
an additional power supply in the chassis to support drives in the lower
bay. The upper and lower hot-docking bays, when fully configured with 10
4 GB hard disk drives, provide over 40 GB of hard disk drive space.
The plastic front door on the front of the server covers a removable metal
door. Two spring-loaded captive screws secure the metal door to the
chassis. These doors provide proper air-flow and easy access to the drives
in the upper and lower hot-docking bays. Plastic drive carriers for 3.5-inch
wide by 1-inch high drives allow easy hot swapping of these drives without
shutting down the server.
With the RPX board installed on the system board, RAID software, and
SCSI hard disk drives in the hot-docking bays, you can easily set up RAID
applications.
M440LX Server System Product Guide
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Onboard RAID
With the RPX board installed on the system board, RAID software, and
SCSI hard disk drives in the hot-docking bays, you can easily set up RAID
applications. A two channel RAID solution can be constructed by installing
an RPX module with RAID firmware resident in the RPX FLASH memory.
The server system supports two types of embedded RAID firmware
packages: I2O compliant and vendor proprietary firmware. The RAID
features are as follows:
•
•
•
RAID levels 0, 1, 3, 5, 0+1, and JBOD
Support for hot spares, hot plugs, and user selectable rebuild rate
Support for multiple rebuilds across separate arrays and multiple
consistency checks
•
•
Write back cache support with battery backup
Support for up to 2 terabytes per logical array and up to 64 terabytes of
attached disk storage
•
Support for SAF-TE and SMART
Server System Board
ISA Expansion Slots
One of the ISA connectors shares a common chassis I/ O expansion slot with
a PCI connector; you can use either ISA or PCI in the slot, but not both.
The ISA bus operates at up to 8.33 MHz and provides
•
•
•
•
24-bit memory addressing
Type A transfers at 5.33 MB per second
Type B transfers at 8 MB per second
8- or 16-bit data transfers
30
Chapter 1 Server Description
Download from Www.Somanuals.com. All Manuals Search And Download.
PCI Expansion Slots
The seven PCI bus master slots on the system board provide for expansion
and performance enhancement. One of the PCI connectors shares a
common chassis I/ O expansion slot with an ISA connector; you can use
either PCI or ISA in the slot, but not both.
The PCI bus operates at up to 33 MHz and provides
•
•
•
•
•
•
32-bit memory addressing
Support for 5 V and 3.3V cards
Burst transfers of up to 133 MB per second
8-, 16-, or 32-bit data transfers
Plug and Play configuration
Hierarchical bus to maximize connectivity
PCI Video Controller
The onboard Cirrus Logic CL-GD54M40 32-bit video graphics accelerator
contains a super video graphics array (SVGA) controller that is fully
compatible with these video standards: CGA†, EGA†, Hercules† Graphics,
MDA†, and VGA. The standard server configuration comes with 512 KB of
onboard video memory allowing pixel resolutions of up to 1024 x 768 and
16 colors.
The SVGA controller supports analog VGA monitors (single and multiple
frequency, interlaced and noninterlaced) with a maximum vertical retrace
interlaced frequency of 87 Hz.
The buffer size of the onboard video memory can be increased from 512 KB
to 1 MB with one 40-pin 256 K x 16, 60 ns fast-page dynamic random access
memory (DRAM). 1 MB of DRAM will allow the controller to support
132-column text modes and high resolution graphics with 1280 x 1024 x 16
colors. Depending on the environment, the controller displays up to 64,000
colors in some video resolutions. It also provides hardware accelerated bit
block transfers (BITBLT) of data.
M440LX Server System Product Guide
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Video Modes
The 54M40 provides all standard VGA modes. With 512 KB of video
memory, the standard server goes beyond standard VGA support. If
necessary, you can install an additional 512 KB of video memory on the
system board. The following tables show all supported video modes that
use 512 KB and 1 MB of video memory.
Table 1-1. Standard VGA Modes
Bits
Per
Colors
(number/palette
Pixel
Frequency
(MHz)
Horizontal
Frequency
(kHz)
Vertical
Frequency
(Hz)
Hexadecimal
Mode Number Pixel size)
Resolution
360 X 400
720 X 400
320 X 200
640 X 200
720 X 400
320 X 200
640 X 200
640 X 350
640 X 350
640 X 480
640 X 480
640 X 480
320 X 200
0, 1
2, 3
4, 5
6
4
4
4
4
4
4
4
4
4
4
4
4
8
16/256K
16/256K
4/256K
2/256K
Mono
14
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
37.5
31.5
70
70
70
70
70
70
70
70
70
60
60
75
70
28
12.5
25
7
28
D
16/256K
16/256K
Mono
12.5
25
E
F
25
10
11
12
12+
13
16/256K
2/256K
16/256K
16/256K
256/256K
25
25
25
31.5
12.5
32
Chapter 1 Server Description
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 1-2. Extended VGA Modes
Bits
Per
Colors
(number/palette
Pixel
Frequency
(MHz)
Horizontal
Frequency
(kHz)
Vertical
Frequency
(Hz)
Hexadecimal
Mode Number Pixel size)
Resolution
1056 X 400
1056 X 350
800 X 600
800 X 600
800 X 600
800 X 600
800 X 600
1024 X 768
14, 55
54
8
8
8
8
8
8
8
8
16/256K
16/256K
16/256K
16/256K
256/256K
256/256K
256/256K
41.5
41.5
40
31.5
31.5
37.8
46.9
35.2
37.9
46.9
35.5
70
70
60
75
56
60
75
87
58, 6A
58, 6A
5C
49.5
36
5C
40
5C
49.5
44.9
5D
16/256K
(interlaced)
5D
5D
5D
5F
5F
60*
8
8
8
8
8
8
16/256K
16/256K
16/256K
256/256K
256/256K
1024 X 768
1024 X 768
1024 X 768
640 X 480
640 X 480
1024 X 768
65
48.3
56
60
70
75
60
75
87
75
78.7
25
60
31.5
37.5
35.5
31.5
44.9
256/256K
(interlaced)
60*
60*
60*
64*
64*
65*
65*
65*
66*
8
256/256K
256/256K
256/256K
64K
1024 X 768
1024 X 768
1024 X 768
640 X 480
640 X 480
800 X 600
800 X 600
800 X 600
640 X 480
65
48.3
56
60
70
75
60
75
56
60
75
60
8
75
8
78.7
25
60
16
16
16
16
16
16
31.5
37.5
35.2
37.8
46.9
31.5
64K
31.5
36
64K
64K
40
64K
49.5
25
32K Direct/256
Mixed
66*
67*
67*
6C*
16
16
16
16
32K Direct/256
Mixed
640 X 480
800 X 600
800 X 600
1280 X 1024
31.5
40
37.5
37.8
46.9
48
75
60
75
87
32K Direct/256
Mixed
32K Direct/256
Mixed
49.5
75
16/256K
(interlaced)
* Requires 1 MB video memory.
M440LX Server System Product Guide
33
Download from Www.Somanuals.com. All Manuals Search And Download.
SCSI Controllers
The system board includes two wide/ fast-20 SCSI controller chips
integrated as PCI bus masters. These controllers support:
•
•
•
•
An 8-bit (narrow SCSI) data path at a data transfer rate of 20 MB/ sec.
A 16-bit (wide SCSI) data path at a data transfer rate of 40 MB/ sec.
Data transfer rates of 133 MB/ sec as PCI bus masters.
The connection of a maximum of seven 8-bit narrow SCSI devices to
each controller.
•
The connection of a mixture of up to fifteen 16-bit wide and/ or 8-bit
narrow SCSI devices to each controller (maximum of seven 8-bit narrow
devices).
The system board also includes a narrow SCSI controller integrated as a PCI
bus master. You can connect a maximum of seven narrow SCSI devices to
this controller.
The SCSI controllers provide active negation outputs, controls for external
differential transceivers, and a disk activity output. Active negation outputs
reduce the chance of data errors by actively driving both polarities of the
SCSI bus and avoiding indeterminate voltage levels and common-mode
noise on long cable runs. The SCSI output drivers can directly drive a
48 milliampere (mA), single-ended SCSI bus with no additional drivers.
IDE Controller
The PIIX4 multifunction device on the system board acts as a PCI-based Fast
IDE controller that supports
•
•
•
•
•
PIO and IDE DMA/ bus master operations
Mode 4 timings
Transfer rates up to 32 MB/ sec
Buffering for PCI/ IDE burst transfers
Master/ slave IDE mode
34
Chapter 1 Server Description
Download from Www.Somanuals.com. All Manuals Search And Download.
Server Management
During normal operation, server management receives information about
server status and monitors power supply voltages and operating
temperature. If server management software determines that the server is
not operating within specified limits, the software attempts to notify a
supervisor or an administrator of the server’s condition. Server
management features are implemented with the following system board
microcontrollers.
Baseboard Management Controller (BMC) does the following:
•
•
•
•
•
Monitors the processor power supply voltage levels
Monitors then processor thermal trip and internal error signals
Monitors the fan sensors
Manages two I2C thermal sensors located near each processor
Manages fault resilient booting (FRB) that controls the ability to boot the
server using either processor in the event of a catastrophic processor
failure
Front Panel Processor (FPP) on the system board does the following:
•
•
Manages power, reset, and front panel NMI buttons
Monitors all power control sources on the front panel, server manager
module, PIIX4, and RTC power control signals
An EEROM associated with the system board temperature sensor contains
the following:
•
•
•
•
•
Chassis ID
System board ID
Power state
System board temperature
Intrusion detection during both power on and off conditions
M440LX Server System Product Guide
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Pentium II Processor
The system board has two connectors for Pentium II processors. The
secondary processor requires a plug-in DC to DC converter on the system
board to provide power to the processor.
In a symmetric multiprocessor (SMP) environment, all processors are equal
and have no preassigned tasks. Distributing the processing loads between
both processors increases system performance. This is particularly useful
when application demand is low and the I/ O request load is high. In an
SMP environment, both processors share a common bus, the same interrupt
structure, and access to common memory and I/ O channels. The SMP
implementation conforms to the Multiprocessor Specification Version 1.4.
Memory Module
The memory module has eight DIMM sockets. The module supports from
16 MB to 1 GB of extended data out (EDO) ECC memory 3.3 V 60 ns
DRAMs, mounted on JEDEC DIMMs. You may install mixed sizes and
types of DRAM DIMMS in the eight memory banks; however, their speeds
must be the same. The BIOS automatically detects and initializes the
memory array.
ECC memory detects and corrects single-bit errors from DRAM in real time,
allowing your system to function normally. It detects all double-bit errors
but does not correct them; it also detects all three-bit and four-bit adjacent
errors in a DRAM nibble but does not correct them. When one of these
multiple-bit errors occurs, the PAC generates an SERR (system error) that
usually halts the system. ECC is calculated on a 64 bit wide memory basis.
36
Chapter 1 Server Description
Download from Www.Somanuals.com. All Manuals Search And Download.
System Configuration Options
Base System Configuration
•
•
System board assembly
Base system chassis
The electro-galvanized metal chassis minimizes electromagnetic
interference (EMI) and radio frequency interference (RFI). It contains:
Three power supply bays with one 360 watt power supply installed
One vertical drive bay that contains a diskette drive
Three standard 5.25-inch drive bays (a CD-ROM drive is installed in
the top bay)
Two bays each with space for five 3.5-inch SCSI hard disk drives (a
SCSI backplane is installed in the top bay)
Nine I/ O expansion slot covers
Two blowers for cooling the processor modules
Two cooling fans
One control panel
•
Uni Processor Kit
Choice of 266MHz or 300MHz processor
Heat sink assembly
Dual processor retention mechanism
Processor termination card
•
•
Memory Module (either an EDO or SDRAM module)
M440LX Server System Product Guide
37
Download from Www.Somanuals.com. All Manuals Search And Download.
System Upgrade Options
The system upgrade options provide enhancement to the capabilities of the
base system. These options do not include memory and peripheral
upgrades.
•
Dual Processor upgrade:
Upgrade from a single processor system to dual processor system. You
must use processors running at the same frequency. This upgrade kit
comes with heat sink assembled processor and VRM. Choose between a
266 MHz or 300 MHz processor.
•
Power supply upgrade:
The system can contain three power supplies. A second power supply
provides additional power or acts as an redundant power supply,
depending on the system configuration. The powershare upgrade kit is
not required to upgrade from two power supplies to three power
supplies.
360 W power supply
Powershare upgrade kit
SCSI backplane upgrade:
•
The SCSI backplane upgrade allows you to use up to 10 hot-swap
drives.
•
•
Rack adapter kit:
The chassis can be mounted into rack with the rack adapter kit.
Embedded RAID (RPX board):
This upgrade provides low cost I2O or non-I2O RAID. This RAID
solution uses the on board dual ultra SCSI channels. The kit includes an
RPX board and the required RAID software. SIMMs for the RPX board
are not included.
■ ■ ■
■ ■ ■
38
Chapter 1 Server Description
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing The System 2
This chapter tells how to
•
•
•
•
•
•
Select a site
Install the Pentium II processor
Install the memory module
Set the line voltage selector switch and check the power cord(s)
Connect input and output devices
Turn on the server and create installation diskettes from the
Configuration Software CD
•
•
Run PC Diagnostics (Testview)
Exit to DOS
M440LX Server System Product Guide
39
Download from Www.Somanuals.com. All Manuals Search And Download.
Selecting a Site
The server operates reliably within the specified environmental limits (see
page 41). Choose a site that is
•
near a grounded, three-pronged power outlet
a. In the United States and Canada, this means a NEMA 5-15R outlet
for 100-120 VAC or a NEMA 6-15R outlet for 200-240 VAC.
b. For international sites, this means a three-pronged power outlet
applicable for the electrical code of the region.
CAUTION
!
▲
▲
Ensure that the power service connection is through a
properly grounded outlet.
•
•
•
clean and dust-free
well ventilated and away from sources of heat
spacious enough to provide sufficient room behind and around the
server so that you can remove AC power from it by unplugging the
power cord from each power supply or wall outlet
Note
✏
For cooling, airflow, and access to the server, allow about
31 centimeters (12.2 inches) of clearance in back,
60 centimeters (23.6 inches) on each side, and 22 centimeters
(9 inches) in front.
•
•
isolated from strong electromagnetic fields and electrical noise caused
by electrical devices—such as air conditioners, large fans, large electric
motors, radio and TV transmitters, and high frequency security devices
away from sources of vibration or physical shock
40
Chapter 2 Installing The System
Download from Www.Somanuals.com. All Manuals Search And Download.
Physical Specifications
Height
Width
Depth
Weight
51.44 cm (20.25 inches)
43.56 cm (17.15 inches)
51.13 cm (20.13 inches)
29 kg (63 lbs.) minimum configuration
44 kg (97 lbs.) maximum configuration
Environmental Specifications
Temperature
Nonoperating
Operating
–40° to 70 °C (–40° to 158 °F)
5° to 35 °C (41° to 95 °F); derated 0.5 °C for every
1000 ft (305 m)
Humidity
Operating wet bulb
Not to exceed 33 °C (91.4 °F) (with diskette drive or
hard disk drive)
Nonoperating
Operating
95% relative humidity (noncondensing) at 55 °C (131 °F)
85% relative humidity (noncondensing) at 35 °C (95 °F)
Shock
Nonoperating
Operating
20 g, 11 msec, 1/2 sine
2.0 g, 11 msec, 1/2 sine
Altitude
Nonoperating
Operating
To 50,000 ft (15,240 m)
To 10,000 ft (3,048 m)
Acoustic noise
Typically <45 dBA at 18° to 24 °C (65° to 75 °F) with five
internal hard disk drives (measured at 1 meter from the
system with the peripherals idle). The noise of the
variable-speed system fan will increase with
temperature and power load. Your selection of
peripherals may change the noise level.
Electrostatic
discharge (ESD)
Tested to 20 kilovolts (kV), no component damage.
(CD-ROM drive tested to 15 kV, manufacturer’s
specification.)
AC Input Power
115 VAC
Single power supply, fully loaded
100 to 120 VAC, 7.7 A, 50/60 Hz
200 to 240 VAC, 4.4 A, 50/60 Hz
230 VAC
M440LX Server System Product Guide
41
Download from Www.Somanuals.com. All Manuals Search And Download.
After Unpacking the Server
Inspect the shipping box for evidence of mishandling during transit. If the
shipping box is damaged, photograph it for reference. After removing the
contents, keep the damaged box and the packing materials. If the contents
appear damaged, file a damage claim with the carrier immediately.
!
▲
WARNING
The minimum server configuration weighs 29 kg (63 lbs.)
and the maximum one weighs 44 kg (97 lbs.). To avoid
personal injury, have someone help you move the server.
Save the shipping boxes and packing materials to repackage the server in
the event you decide to move it to another site.
Installing the Pentium II Processor
The server is shipped without the processor module installed on the system
board. Turn to Chapter 4, “Working Inside Your System,” and follow the
instructions for installing the processor module. Before you install the
module in your server, observe the warnings and cautions provided for
your safety on page 3, “Safety Guidelines.”
Installing the Memory Module
The server is shipped without the memory module installed on the system
board. Turn to Chapter 4, “Working Inside Your System,” and follow the
instructions for installing the memory module. Before you install the
module in your server, observe the warnings and cautions provided for
your safety on page 3, “Safety Guidelines.”
42
Chapter 2 Installing The System
Download from Www.Somanuals.com. All Manuals Search And Download.
Connecting Peripheral Devices
If your system normally operates without a monitor or keyboard—for
example, as a network server—you must install them to configure the
system. You may remove them after running the SCU. For information
about running this utility, see Chapter 3, “Configuring The System,”.
Connect your keyboard, mouse, monitor, and other peripheral devices after
installing all internal options and replacing the side cover. See Figure 2-1.
Warnings and Cautions
Before connecting peripheral devices to the server, observe the warnings
and cautions provided for your safety on page 3, “Safety Guidelines.”
Server integration should be done by a qualified technical person.
Keyboard
Insert the cable connector of a PS/ 2-compatible keyboard into the 6-pin
miniature Deutsche Industrie Norm (DIN) connector on the system back
panel. The keyboard port is overcurrent-protected by a 1-ampere positive
temperature coefficient (PTC) resistor.
Mouse
Insert the cable connector of a PS/ 2-compatible mouse into the 6-pin
miniature DIN connector on the system back panel. The mouse port is
overcurrent-protected by a 1-ampere PTC resistor.
Monitor
Insert the cable connector of the video monitor into the 15-pin connector of
the Super VGA port on the system back panel.
Other Devices
Connect other external peripheral devices—for example, a printer and an
external modem—by following the instructions in the documentation
included with the device. Besides the keyboard, mouse, and monitor ports,
the back panel also provides two serial ports, and a parallel port.
M440LX Server System Product Guide
43
Download from Www.Somanuals.com. All Manuals Search And Download.
1
6
2
3
5
4
OM05779A
Figure 2-1. Server I/O Panel
1. PS/2-compatible keyboard connector
2. PS/2-compatible mouse connector
3. PS/2-compatible serial port 1 (COM1) connector
4. PS/2-compatible parallel port (LPT1) connector
5. Super VGA connector
6. PS/2-compatible serial port 2 (COM2) connector
44
Chapter 2 Installing The System
Download from Www.Somanuals.com. All Manuals Search And Download.
Checking the Power Cord(s)
!
▲
WARNING
Do not attempt to modify or use a supplied AC power
cord if it is not the exact type required.
If a power cord supplied with the system is not compatible with the AC
wall outlet in your region, get one that meets the following criteria:
•
The cord must be rated for the available AC voltage and have a current
rating that is at least 125% of the current rating of the system.
•
The connector that plugs into the wall outlet must be a grounding-type
male plug designed for use in your region. It must have certification
marks showing certification by an agency acceptable in your region.
•
•
The connector that plugs into the AC receptacle on the system power
supply must be an IEC 320, sheet C13, type female connector.
In Europe, the cord must be less than 4.5 meters (14.76 feet) long, and it
must be flexible <HAR> (harmonized) or VDE certified cordage to
comply with the system's safety certifications.
Turning on Your Server
!
▲
WARNINGS
Ensure that the line voltage selector switch on each power
supply is set to the correct line source voltage (see
page 42). If the setting is incorrect, the power supply will
be damaged when you plug the power cord into an AC
outlet.
The power button on the front panel of the server does not
turn off the AC power. To remove AC power from the
server, you must unplug the AC power cord from each
power supply or wall outlet.
1. Make sure all external devices, such as a monitor, keyboard, and mouse
(optional) have been connected.
2. Remove drive protection cards (if present) from the diskette and tape
drives.
3. Turn on your video monitor.
M440LX Server System Product Guide
45
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Plug the female end of each AC power cord into each input receptacle
on the back of the chassis (your server may be configured with one, two,
or three power supplies).
5. Plug the male end of the cord into a grounded, three-pronged power
outlet. (Repeat for each power supply in the server.)
6. If the server doesn’t come on when you plug it into the AC outlet, press
the power button (Figure 2-2).
7. Verify that the power-on light on the front panel is lit. After a few
seconds POST begins. See “Power-on Self-Test.”
3
1
2
OM05780
Figure 2-2. Power and Reset Buttons
1. Power button
2. Reset button
3. Power-on light (LED)
Power-on Self-Test
Each time you turn on the server, the power LED on the front panel turns
on and the power-on self-test (POST) starts running. It checks the system
board, processor, memory, keyboard, and most installed peripheral devices.
During the memory test, the POST displays the amount of memory that it is
able to access and test. Depending on the amount of memory installed on
the memory module, it may take several minutes to complete the memory
test.
46
Chapter 2 Installing The System
Download from Www.Somanuals.com. All Manuals Search And Download.
Creating Installation Software Diskettes
1. Insert the Configuration Software CD in the CD-ROM Drive.
2. Reboot the system.
3. When POST completes, the server boots from the CD and displays the
CD-ROM menu.
4. Follow the menu prompts to create the server configuration software
diskettes.
■ ■ ■
■ ■ ■
M440LX Server System Product Guide
47
Download from Www.Somanuals.com. All Manuals Search And Download.
48
Chapter 2 Installing The System
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring The System 3
This chapter tells how to run the configuration utilities and install video
drivers.
Configuration Utilities
•
Symbios SCSI Utility is used to configure/ view the settings of the SCSI
host adapters and devices in the system. See page 76.
•
System Configuration Utility (SCU) is on the Configuration Software
CD shipped with the system. See Chapter 2, “Installing The System,”
for instructions on creating an SCU diskette. See page 51.
•
BIOS Setup Utility is stored in both flash memory and the battery-
backed memory of the real-time clock (RTC) on the system board. See
page 59.
If the diskette drive is disabled or improperly configured, use Setup to
enable it so that you can run the SCU. If necessary, disable the drive after
exiting the SCU. Information entered using the SCU overrides any entered
using Setup.
M440LX Server System Product Guide
49
Download from Www.Somanuals.com. All Manuals Search And Download.
Power-on Self-Test
!
▲
WARNING
The power button on the front panel of the system does
not turn off the AC power. To remove AC power from the
system, you must unplug the AC power cord from each
power supply or wall outlet.
Turn on the video monitor and system. After a few seconds the power-on
self test (POST) begins.
Each time you turn on the system the power LED on the front panel turns
on and the POST starts running. The POST checks the system board,
processor, memory, keyboard, and most installed peripheral devices.
During the memory test, the POST displays the amount of memory that it is
able to access and test. Depending on the amount installed on the memory
module, the test may take several minutes to complete.
These screen prompts and messages appear after the memory test:
Press F2 key if you want to run SETUP
If you do not press <F2>, the boot process continues, and this message
appears:
Press Ctrl C to start configuration Utility!
If you have installed SCSI devices in the system, press <Ctrl+C>. When the
utility appears, follow the instructions on the monitor to configure the
onboard SCSI host adapter settings and run the SCSI disk utilities. See
“Using the Symbios SCSI Utility” on page 76.
50
Chapter 3 Configuring The System
Download from Www.Somanuals.com. All Manuals Search And Download.
When to Use the System Configuration Utility
The SCU lets you do the following:
•
•
•
•
Add and remove boards
Change the system configuration settings
Save the system configuration
View switch and jumper settings on the boards in the system
To install or remove an ISA add-in board in the system, you must run the
SCU to reconfigure the system. Running the SCU is optional for a PCI
add-in board.
The SCU is PCI-aware and complies with the ISA Plug and Play
specifications. The SCU works with any compliant configuration (.CFG) or
overlay (.OVL) files supplied by peripheral device manufacturer.
The system board comes with .CFG and .OVL files. The .CFG file describes
the board’s characteristics and the system resources that the board requires.
The configuration registers on PCI and ISA Plug and Play add-in boards
contain the same type of information that is in a .CFG file. However, some
ISA add-in boards do come with a .CFG file.
The SCU uses the information provided by the .OVL and .CFG files,
configuration registers, NVRAM, and the information that you enter, to
specify a system configuration. It configures the system by writing the
configuration information to flash memory.
The SCU stores most of the configuration values in the battery-maintained
memory (NVRAM) of the real-time clock (RTC), and it stores the rest of the
values in flash memory. These values take effect when you boot the system.
The POST checks the values against the actual hardware configuration; if
they do not agree, it generates an error message. You must then run the
SCU to specify the correct configuration before the system boots.
The SCU always updates a checksum for both areas so that the BIOS can
detect any potential data corruption before the actual hardware
configuration takes place. If the data is corrupted, the BIOS requests that
the user configure the system before it can boot.
Pressing <F1> on the keyboard, in response to the BIOS prompt during the
POST, activates the BIOS Setup Utility.
M440LX Server System Product Guide
51
Download from Www.Somanuals.com. All Manuals Search And Download.
How to start the SCU
Before you can run the SCU from a diskette, you must copy the SCU from
the Configuration Software CD to a DOS bootable diskette. For instructions
on creating an SCU diskette, see Chapter 2, “Installing The System.”
1. Turn on the video display monitor and system.
2. There are three ways to start the SCU.
•
•
•
After creating an SCU diskette from the CD: Insert the
System Configuration Utility Disk in drive A, and press the
reset push-button switch or <Ctrl+Alt+Del> to reboot the
system from the diskette.
After installing the operating system: Insert the System
Configuration Utility Disk in drive A, and copy it to a
directory on the hard drive. While in the directory, type
AMISCU and press <Enter>.
From diskette after installing the operating system: Insert
the System Configuration Utility Disk in drive A. At the
MS-DOS† prompt, type a: and press <Enter> to change to
drive A. Type AMISCU and press <Enter> to start the SCU.
When you see this message:
MS-DOS Startup Menu
-------------------------------
1. Execute AMISCU
2. Execute AMISCU for system with PNP OS
If the operating system in the system supports Plug and Play add-in
boards, press <2> to start the SCU. If not, press <1> to start it.
3. When the SCU title appears on the screen, press <Enter> to continue.
↑
↓
4. From the main menu, press < > or < > to highlight an item and then
press <Enter> to select it. If you are using a mouse, point to an item and
double-click the left button to select it. Press <F1> at any time for help
about a selection.
5. For information about setting up the system select “Step 1: About
System Configuration” from the main menu.
52
Chapter 3 Configuring The System
Download from Www.Somanuals.com. All Manuals Search And Download.
System Board Settings Field Descriptions
Default values are in bold typeface.
Systems Group
System Identification and Version Information
Config and Overlay Version
BIOS Version String
MP Spec. Version
Displays configuration and overlay version.
Displays BIOS version.
MP Spec V1.1
MP Spec V1.4
System Processor Modules
Processor 1
Pentium II Processor at XXXMHz (Display only).
Pentium II Processor at XXXMHz (Display only).
Processor 2
Memory Subsystem Group
Shadowing ISA ROMs Options
Shadowing ISA ROM at C8000
Shadowing ISA ROM at CC000
Shadowing ISA ROM at D0000
Shadowing ISA ROM at D4000
Shadowing ISA ROM at D8000
Shadowing ISA ROM at DC000
Enable
Disable
Enable
Disable
Enable
Disable
Enable
Disable
Enable
Disable
Enable
Disable
M440LX Server System Product Guide
53
Download from Www.Somanuals.com. All Manuals Search And Download.
Extended Memory Options
Cache Mode
Disable
Enable
Memory Gap Control
Disable
Extended
On-Board Disk Controllers
On-Board Floppy Controller
Enable - Primary
Enable - Secondary
Disable
On-Board IDE Controller
Enable
Disable
Onboard Communications Devices
Serial Port 1 Configuration
Serial Port 2 Configuration
Serial Port 2 Mode
Port 1 Disable
3E8h - IRQ 4
3E8h - IRQ 3
3F8h - IRQ 4
3F8h - IRQ 3
2E8h - IRQ 4
2E8h - IRQ 3
2F8h - IRQ 4
2F8h - IRQ 3
Port 2 Disable
3E8h - IRQ 4
3E8h - IRQ 3
3F8h - IRQ 4
3F8h - IRQ 3
2E8h - IRQ 4
2E8h - IRQ 3
2F8h - IRQ 4
2F8h - IRQ 3
Port 2 Normal Mode
Port 2 IrDA† Mode
Port 2 ASK-IR Mode
54
Chapter 3 Configuring The System
Download from Www.Somanuals.com. All Manuals Search And Download.
Parallel Port Configuration
Parallel Port Disable
378h - IRQ 7
278h - IRQ 7
3BCh - IRQ 7
378h - IRQ 5
278h - IRQ 5
3BCh - IRQ 5
Parallel Port Mode
Output Only Parallel Port
Bi-directional Parallel Port
Enhanced Parallel Printer Port
Extended Capabilities Parallel Port, DMA 1
Extended Capabilities Parallel Port, DMA 3
Floppy Drive Subsystems Group
Floppy drive A Options
3.5-inch 1.44/1.25 MB drive
5.25-inch 360 KB drive
5.25-inch 1.2 MB drive
3.5-inch 720 KB drive
3.5-inch 2.88 MB drive
Disable or Not Installed
Floppy drive B Options
Disable or Not Installed
5.25-inch 1.2 MB drive
5.25-inch 360 KB drive
3.5-inch 2.88 MB drive
3.5-inch 1.44/1.25 MB drive
3.5-inch 720 KB drive
IDE Subsystem Group
IDE Configuration – Primary Master
Configuration Selection
None
User
Auto
CD
M440LX Server System Product Guide
55
Download from Www.Somanuals.com. All Manuals Search And Download.
IDE Drive Options – Primary Master
If the Configuration Selection Field is set to Auto, the following fields can
not be modified.
Multi-Sector Transfer
2 Sector/Block
4 Sector/Block
8 Sector/Block
16 Sector/Block
Disable
Translation Mode
Transfer Mode
Standard CHS
Logical Block Addressing
Standard
PIO 1
PIO 2
PIO 3
PIO 4
IDE Configuration – Primary Slave
Configuration Selection
None
User
Auto
CD
IDE Drive Options – Primary Slave
If the Configuration Selection Field is set to Auto, the following fields can
not be modified.
Multi-Sector Transfer
2 Sector/Block
4 Sector/Block
8 Sector/Block
16 Sector/Block
Disable
Translation Mode
Transfer Mode
Standard CHS
Logical Block Addressing
Standard
PIO 1
PIO 2
PIO 3
PIO 4
56
Chapter 3 Configuring The System
Download from Www.Somanuals.com. All Manuals Search And Download.
Multiboot Group
Boot Device Priority
IPL Devices
Diskette Drive
Hard Drive
Removable media
Any I2O drives
ATAPI CD-ROM Drive
Diagnostic Boot
BCV Devices
IDE drives
Other Bootable Device
KB and Mouse Subsystem Group
Typematic Speed
30 CPS
26 CPS
21 CPS
18 CPS
13 CPS
10 CPS
6 CPS
2 CPS
Typematic Delay
250 mS Delay
500 mS Delay
750 mS Delay
1000 mSec Delay
Mouse Control Option
Mouse Enabled
Mouse Disabled
Console Redirection
COM Port for Redirection
Enable Redirection on Port 3F8h IRQ4
Enable Redirection on Port 2F8h IRQ3
Enable Redirection on Port 3E8h IRQ3
Disable
Serial Port Baud Rate
9600 Baud
19.2K Baud
38.4K Baud
115.2K Baud
M440LX Server System Product Guide
57
Download from Www.Somanuals.com. All Manuals Search And Download.
Hardware Flow Control
None
CTS/RTS
Xoff/Xon
CTS/RTS + CD
Select Terminal Type
PC-ANSI
VT100
Security Subsystem
Administrative Password Option
Password Menu
Enter Password XXXXX
Verify Password XXXXX
User Password Option
Password Menu
Enter Password XXXXX
Verify Password XXXXX
Other Security Subsystem Options
Hot Key Option
Disable
Enable
Lockout Timer
Disable
1 Minute
2 Minute
5 Minute
10 Minute
20 Minute
1 Hour
2 Hour
Secure Boot Mode
Video Blanking
Floppy Writes
Disable
Enable
Disable
Enable
Disable
Enable
58
Chapter 3 Configuring The System
Download from Www.Somanuals.com. All Manuals Search And Download.
SCSI ROM BIOS Options Group
Embedded SCSI Option ROM
Scan
Enable
Disable
Management Subsystem Group
System Management Mode
Disable
Enable
Event Logging
Disable
Enable
M440LX Server System Product Guide
59
Download from Www.Somanuals.com. All Manuals Search And Download.
When to Run the BIOS Setup Utility
The Setup utility lets you change the system configuration defaults. It does
not let you enter or change information about PCI or ISA add-in boards; you
must use the SCU instead. Setup stores most of the configuration values in
the battery-backed memory of the RTC; the rest of the values are stored in
flash memory. The values take effect when you boot the system. The POST
checks these values against the actual hardware configuration; if they do not
agree, it generates an error message. You must then run Setup to specify
the correct configuration.
You can run the Setup utility with or without an operating system being
present.
Since values entered using the Setup utility are overwritten when you run
the SCU, you should only run Setup under the following conditions:
•
•
•
To enable the diskette drive
If you do not have access to a diskette drive
If you do no want to configure any ISA add-in boards in the system
Running the Setup Utility
Reset the system. When you see this message:
Press F2 key if you want to run SETUP
Press <F2> to run Setup.
Setup provides six major menus and nine submenus:
•
Main Menu
Primary IDE Master Submenu
Primary IDE Slave Submenu
Keyboard Features Submenu
Advanced Menu
•
•
PCI Configuration Submenu
Integrated Peripheral Configuration Submenu
Security Menu
60
Chapter 3 Configuring The System
Download from Www.Somanuals.com. All Manuals Search And Download.
•
•
•
Server Menu
System Management Submenu
Console Redirection Submenu
Boot Menu
Boot Device Priority Submenu
Hard Drive Submenu
Exit Menu
Use the following keys to navigate through the menus and submenus.
Press
To
F1
Get help about an item
Go back to a previous item
Select an item
ESC
Enter
↑
Return to a previous item
Move to the next Item
Select a major menu
Load Setup defaults
Return to previous values
Save and exit Setup
↓
← →
F5
F6
F10
M440LX Server System Product Guide
61
Download from Www.Somanuals.com. All Manuals Search And Download.
Main Menu
Default values are in bold typeface, and autoconfigured values are shaded.
Feature
Option
Comments
System Time
System Date
Diskette A:
Current Time
To change this field type the hour (this
is a 24-hour clock), minutes, and
seconds, each followed by <Enter>.
Current Date
To change this field type the month,
day, and year, each followed by
<Enter>.
Disabled
360 KB 5¼”
1.2 MB 5¼”
720 KB 3½”
1.44/1.25 MB 3½”
2.88 MB 3½”
Diskette B:
Disabled
360 KB 5¼”
1.2 MB 5¼”
720 KB 3½”
1.44/1.25 MB 3½”
2.88 MB 3½”
Primary IDE Master
Primary IDE Slave
Keyboard Features
Press <Enter>
Press <Enter>
Press <Enter>
See page 63, IDE Submenu.
See page 63, IDE Submenu.
See page 64, Keyboard Features
Submenu.
Memory Cache
Enabled
Disabled
CPU Speed Setting
133 MHz
233 MHz
266 MHz
300 MHz
333 MHz
To activate this field, see Chapter 8,
“System Board Jumpers”.
Language
English (US)
German
French
Italian
Spanish
62
Chapter 3 Configuring The System
Download from Www.Somanuals.com. All Manuals Search And Download.
IDE Submenu
Feature
Option
Comments
Type
Auto
None
CD-ROM
User
Use the <+> and <-> keys to cycle
through the choices. Depending on
the selection, some of the following
fields will be visible.
Multi-Sector
Transfers
Disabled
2 Sectors
4 Sectors
8 Sectors
16 Sectors
Determines the number of sectors per
block for multiple sector transfers.
LBA Mode Control
32 Bit I/O
Disabled
Enabled
Disables/Enables Logical Block
Access.
Disabled
Enabled
Disables/Enables 32-bit IDE data
transfers.
Transfer Mode
Standard
Fast PIO 1
Fast PIO2
Fast PIO3
Fast PIO4
Selects the method for moving data
to/from the drive.
Cylinders
Heads
0
0
Sectors/Track
Maximum Capacity
0
X MB
The system calculates this number
from the cylinders, heads, and
sectors/track numbers.
M440LX Server System Product Guide
63
Download from Www.Somanuals.com. All Manuals Search And Download.
Keyboard Features Submenu
Feature
Option
Comments
Numlock
Key Click
Auto
On
Off
Selects the state for NumLock at
power on.
Disabled
Enabled
Keyboard auto-repeat
rate
30/sec
26.7/sec
21.8/sec
18.5/sec
13.3/sec
10/sec
6/sec
2/sec
Keyboard auto-repeat
delay
1/4 sec
1/2 sec
3/4 sec
1 sec
64
Chapter 3 Configuring The System
Download from Www.Somanuals.com. All Manuals Search And Download.
Advanced Menu
Feature
Option
Comments
Plug & Play OS
No
Yes
Select Yes if you are booting a Plug
and Play capable operating system.
Reset Configuration
Data
No
Yes
Select Yes if you want to clear the
System Configuration Data during the
next boot. Automatically reset to No
during boot.
PCI Configuration
Press <Enter>
Press <Enter>
See page 66, PCI configuration
Submenu.
Integrated Peripheral
Configuration
See page 68, Integrated Peripheral
Configuration Submenu.
Use Multiprocessor
Specification
1.1
1.4
Large Disk Access
Mode
DOS
Other
DOS - select DOS
UNIX†, Novell† NetWare†, or other OS
- select Other.
Enable Memory Gap
Disabled
Extended
Delay on Option
ROMS
Disabled
Enabled
Clock control
Enabled
Disabled
Enabled programs the clock drivers to
optimum settings
IO processor
Enabled
Disabled
Enables onboard IO processor
(i960 RD)
M440LX Server System Product Guide
65
Download from Www.Somanuals.com. All Manuals Search And Download.
PCI Configuration Submenu
Feature
Option
Comments
PCI Device,
Embedded SCSI
Devices
Press <Enter>
See page 67, Embedded SCSI Device
Submenu
PCI Device, Slot #1
PCI Device, Slot #2
PCI Device, Slot #3
PCI Device, Slot #4
PCI Device, Slot #5
PCI Device, Slot #6
PCI Device, Slot #7
Press <Enter>
Press <Enter>
Press <Enter>
Press <Enter>
Press <Enter>
Press <Enter>
Press <Enter>
See page 68, PCI Device Submenu
See page 68, PCI Device Submenu
See page 68, PCI Device Submenu
See page 68, PCI Device Submenu
See page 68, PCI Device Submenu
See page 68, PCI Device Submenu
See page 68, PCI Device Submenu
66
Chapter 3 Configuring The System
Download from Www.Somanuals.com. All Manuals Search And Download.
Embedded SCSI Device Submenu
Feature
Option ROM Scan
Option
Comments
Enabled
Disabled
Narrow SCSI Latency
Timer
Default
0020h
0040h
0060h
0080h
00A0h
00C0h
00E0h
Wide SCSI A Latency
Timer
Default
0020h
0040h
0060h
0080h
00A0h
00C0h
00E0h
Wide SCSI B Latency
Timer
Default
0020h
0040h
0060h
0080h
00A0h
00C0h
00E0h
M440LX Server System Product Guide
67
Download from Www.Somanuals.com. All Manuals Search And Download.
PCI Device Submenu
Feature
Option
Comments
Option ROM Scan
Enabled
Disabled
Enable Master
Disabled
Enabled
Wide SCSI A Latency
Timer
Default
0020h
0040h
0060h
0080h
00A0h
00C0h
00E0h
Integrated Peripherals Submenu
Feature
Option
Comments
Serial port A
Disabled
Enabled
Auto
PnP OS
Serial port A: Base
I/O address
3F8
2F8
3E8
2E8
Serial port A:
Interrupt
IRQ 3
IRQ 4
Serial port B
Disabled
Enabled
Auto
PnP OS
Serial port B: Mode
Normal
IrDA
ASK-IR
continued
68
Chapter 3 Configuring The System
Download from Www.Somanuals.com. All Manuals Search And Download.
(continued)
Integrated Peripherals Submenu
Feature
Serial port B: Base
Option
Comments
3F8
2F8
3E8
2E8
I/O address
Serial port B:
Interrupt
IRQ 3
IRQ 4
Parallel port
Disabled
Enabled
Auto
PnP OS
Parallel port: Mode
Output only
Bi-directional
EPP
ECP
Parallel port: Base
I/O address
378
278
Parallel port:
Interrupt
IRQ 5
IRQ 7
Parallel port: DMA
Channel
DMA 1
DMA 3
Floppy Disk
Controller
Disabled
Enabled
Floppy Disk
Controller: Base I/O
address
Primary
Secondary
M440LX Server System Product Guide
69
Download from Www.Somanuals.com. All Manuals Search And Download.
Security Menu
Feature
Option
Comments
User Password is
Clear
When you enter a supervisor
password, this field automatically
changes to Set.
Administrator
Password is
Clear
When you enter a user password, this
field automatically changes to Set.
Set User Password
Press <Enter>
User password controls access to the
system at boot. Password may be
from one to seven characters. See
page 71, Password Menu.
Set Administrative
Password
Press <Enter>
Supervisor password controls access
to the setup utility. Password may be
from one to seven characters. See
page 71, Password Menu.
Password On Boot
Diskette Access
Disabled
Enabled
Enabled requires password to boot the
system. Password On Boot takes
precedence over Secure Mode Boot.
User
Administrator
Fixed Disk Boot
Sector
Normal
Write Protect
Write-protects hard disk boot sector to
guard against viruses.
System Backup
Reminder
Disabled
Daily
Weekly
Monthly
Virus Check
Reminder
Disabled
Daily
Weekly
Monthly
continued
70
Chapter 3 Configuring The System
Download from Www.Somanuals.com. All Manuals Search And Download.
Security Menu (continued)
Feature
Option
Comments
Secure Mode Timer
Disabled
1 min
2 min
5 min
10 min
20 min
1 hr
Select the period of keyboard inactivity
before securing the system.
2 hr
Secure Mode Hot
Key (CTRL-ALT-)
Enter a hot key. Press <CTRL + Alt>
+ <(hot key)> to place the system in
the secure mode.
Secure Mode Boot
Disabled
Enabled
Enabled lets the system boot before a
password is required. However, the
keyboard and mouse remain locked
until the user password is entered.
Video Blanking
Disable
Enable
Floppy Write Protect
Disabled
Enabled
Password Submenu
Feature
Option
Comments
Enter New Password
(password
field)
Type a password in this field, and
press <Enter> or <Tab>. Press
ESC to abort.
Confirm New Password
(confirm
password
field)
Type a password again, and press
<Enter> or <Tab> to accept it.
Press ESC to abort.
M440LX Server System Product Guide
71
Download from Www.Somanuals.com. All Manuals Search And Download.
Server Menu
Feature
Option
Comments
System Management
Press <Enter>
See page 72, System Management
Submenu.
Console Redirection
Press <Enter>
See page 73, Console Redirection
Submenu.
PCI IRQs to IO-APIC
mapping
Disabled
Enabled
Processor Retest
No
Yes
Selecting Yes will cause the BIOS to
clear the historical processor status
and retest all processors on the next
boot.
System Management Submenu
Feature
Option
Comments
System Management Mode
Disabled
Enabled
Loads the embedded Server
Management firmware.
System Event Logging
Clear Event Log
Disabled
Enabled
When Enabled, system events will
be logged by BIOS and the BMC.
No
Yes
If set to yes, the event log will be
cleared on the next boot.
Memory Scrubbing
PERR# Reporting
Disabled
Enabled
Disabled
SMI Only
SMI & NMI
SERR# Reporting
Disabled
Enabled
Server Management Info
Press <Enter>
Displays board and firmware
revision information.
72
Chapter 3 Configuring The System
Download from Www.Somanuals.com. All Manuals Search And Download.
Console Redirection Submenu
Feature
Option
Comments
COM Port Address
Disabled
3F8
Uses the specified I/O port for
console redirection.
2F8
3E8
IRQ #
4
Display only.
COM Port Baud Rate
9600
Uses the specified baud rate for
console redirection. Cannot be set
unless the COM Port Address field
is set.
19.2 K
38.4 K
115.2 K
Flow Control
No Flow
Control
CTS/RTS
XON/XOFF
CTS/RTS +
CD
Uses the specified flow control for
console redirection. Cannot be set
unless the COM Port Address field
is set.
Boot Menu
Feature
Option
Comments
Floppy check
Disabled
Enabled
If Enabled, the system verifies
floppy type on boot. Disable results
in a faster boot.
Summary screen
Boot Device Priority
Hard Drive
Disabled
Enabled
Displays system configuration on
boot.
Press <Enter>
See page 74, Boot Device Priority
Submenu.
Press <Enter>
See page 74, Hard Drive Submenu.
M440LX Server System Product Guide
73
Download from Www.Somanuals.com. All Manuals Search And Download.
Boot Device Priority Submenu
These options may change depending on the system configuration.
Feature
Option
Comments
1
Diskette Drive
Select a device and use the <+> and
<-> keys to move it up or down in
the list.
2
3
Hard Drive
ATAPI CD-
ROM Drive
4
Diagnostic
Boot
Hard Drive Submenu
These options may change depending on the system configuration.
Feature
Option
Comments
1
2
Hard Drive
Select a device and use the <+> and
<-> keys to move it up or down in
the list.
Other
Bootable Card
Other bootable cards covers all the
boot devices that are not reported to
the system BIOS. It may or may not
be bootable, and may not
correspond to any device.
74
Chapter 3 Configuring The System
Download from Www.Somanuals.com. All Manuals Search And Download.
Exit Menu
Feature
Option
Comments
Exit Saving Changes
Press <Enter>
Saves the Setup data to CMOS, and
exits the utility.
Exit Discarding Changes
Load Setup Defaults
Load Custom Defaults
Save Custom Defaults
Press <Enter>
Press <Enter>
Press <Enter>
Press <Enter>
Exits the utility without saving Setup
data to CMOS.
Loads and displays the default
Setup data.
Loads and displays settings from
Custom Defaults.
Save the current settings to Custom
Defaults.
Discard Changes
Save Changes
Press <Enter>
Press <Enter>
Loads the last values saved.
Saves the Setup data to CMOS
without stopping the utility.
M440LX Server System Product Guide
75
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Symbios SCSI Utility
The Symbios SCSI utility detects the SCSI host adapters on the system
board. Use the utility to
•
•
change default values
check and/ or change SCSI device settings that may conflict with those
of other devices in the server
Running the SCSI Utility
1. When this message appears on the video monitor:
Press Ctrl-C to run SCSI Utility...
2. Press <Ctrl+C> to run this utility. When it appears, choose the host
adapter that you want to configure.
Hot Keys
Use the keyboard’s numeric pad to enter numbers and symbols.
To
Press these keys
Clear memory and reload the operating
system—this is a soft boot reset.
<Ctrl+Alt+Del>
Secure the server system immediately.
<CTRL + Alt> + <(hot key)> (Set
the hot-key with the SCU)
76
Chapter 3 Configuring The System
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing Video Drivers
After you have configured the system, you can install various video drivers
to take full advantage of its onboard, integrated Cirrus Logic CL-GD54M40
super VGA video controller’s enhanced features. The system may not
operate properly without these video drivers installed.
For the most current information on which video drivers you need, read the
README.TXT file on the Display Drivers and DOS Utilities diskette. To
install drivers from the diskettes, follow the installation instructions in the
README.TXT file.
The video drivers are on the Configuration Software CD. For instructions
on creating Video diskettes, see Chapter 2, “Installing The System.”
To install these video drivers, do this:
1. Fully configure the system. (This may include adding video DRAM
buffer memory, application software, or new ISA or PCI add-in boards.)
2. Insert disk 1 of the video drivers and utilities for MS-DOS and
Windows† into drive A.
3. At the DOS command prompt, type A:install and press <Enter>.
4. Follow the directions on the monitor to install the video drivers.
If the system does not operate as described in this chapter, follow the
instructions in Chapter 10, “Solving Problems.”
Installing SCSI Drivers
The SCSI drivers are on the Configuration Software CD. For instructions on
creating SCSI diskettes, see Chapter 2, “Installing The System.” To install
the SCSI drivers, follow the instructions in the README.TXT file on the
first diskette.
■ ■ ■
■ ■ ■
M440LX Server System Product Guide
77
Download from Www.Somanuals.com. All Manuals Search And Download.
78
Chapter 3 Configuring The System
Download from Www.Somanuals.com. All Manuals Search And Download.
Working Inside Your System 4
This chapter tells how to install and remove major system components.
Preparation
Before opening your system, do the following:
•
•
Turn the system off with the power button on the front panel and
unplug the AC power cord(s).
Turn off all peripheral devices connected to the system. Label and
disconnect all peripheral cables attached to the I/ O panel on the back of
the system.
•
If you installed a padlock, unlock and remove it.
Warnings and Cautions
Before you remove the covers, observe the warnings and cautions provided
for your safety on page 3, “Safety Guidelines.”
System integration should be done by technically qualified personnel.
Tools and Supplies You Need
•
•
Phillips screwdriver (#2 bit)
Antistatic wrist strap (recommended)
Equipment Log
Use the equipment log form provided in Appendix B, “Equipment Log,” to
record the model and serial numbers of the system, all installed options,
and any other pertinent information specific to the system. You will need
this information when running the SCU.
M440LX Server System Product Guide
79
Download from Www.Somanuals.com. All Manuals Search And Download.
Covers
The system comes with the following removable covers:
•
•
The left side cover provides access to the system board and fans.
The right side cover provides access to the power supplies, power-
sharing board, 3.5-inch vertical drive bay, 5.25-inch horizontal
peripheral bays, and SCSI hot-docking backplanes.
•
•
The top cover provides access to the front panel board. You must
remove both side covers before you can remove the top cover.
The plastic front cover provides access to the front of the chassis and the
5.25-inch horizontal peripheral bays. You must remove both side covers
and the top cover before you can remove the front cover.
•
The snap-in plastic peripheral bay cover provides access to the 5.25-inch
horizontal peripheral bays without the need to remove other covers.
CAUTION
!
▲
▲
For proper cooling and airflow, do not operate the system
with the covers removed. Always replace them before
turning on the system.
Removing a Side Cover
The side covers are interchangeable. See Figure 4-1.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Remove the three screws from the side cover, and save them.
3. Slide the cover backwards, about an inch, until it stops.
4. Pull the back end of the cover toward you to disengage its tabs from the
slots in the chassis. Set the cover aside.
80
Chapter 4 Working Inside Your System
Download from Www.Somanuals.com. All Manuals Search And Download.
1
2
3
OM05785
Figure 4-1. Side Covers
1
2
3
Retaining screw
Metal loop (for padlock)
Built-in handle
Replacing a Side Cover
The identical side covers can be installed on either side of the system. See
Figure 4-1.
1. Before replacing the side cover, make sure you did not leave any tools
or loose parts inside the chassis.
2. Ensure that add-in boards are firmly seated in their respective slots,
retaining brackets are firmly secured with screws tightened to
6.0 inch-pounds, and interior cables are properly connected.
3. Position the side cover over the chassis so that the metal tabs across the
top and bottom edges of the cover align with the slots in the top cover
and bottom edge of the chassis. Slide the cover toward the front of the
system so that the tabs along the front edge of the cover firmly engage
in the front slots of the chassis.
M440LX Server System Product Guide
81
Download from Www.Somanuals.com. All Manuals Search And Download.
CAUTION
!
▲
▲
When you replace the side cover, be careful not to damage
the EMI gaskets mounted on the cover and chassis. If
necessary, replace any damaged gaskets.
4. Attach the cover to the chassis with the three screws you removed
earlier, and tighten them firmly (6.0 inch-pounds).
5. For security, and to prevent unauthorized entry into the system, insert a
padlock through the metal loop protruding through the slot in the back
of the side cover and lock it.
6. Connect all external cables and the power cord(s) to the system.
Removing the Top Cover
See Figure 4-2.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Remove both side covers and set them aside (page 80).
3. Remove the three screws from the top cover, and set them aside.
4. Slide the cover backwards until the tabs along the front of the cover
disengage from the slots in the chassis.
5. Lift the cover off and set aside.
82
Chapter 4 Working Inside Your System
Download from Www.Somanuals.com. All Manuals Search And Download.
2
1
OM05256
Figure 4-2. Top Cover
1
2
Screw
Top cover
Replacing the Top Cover
See Figure 4-2.
1. Before replacing the top cover, make sure you did not leave any tools or
loose parts inside the chassis.
2. Ensure that interior cables are properly connected.
3. Position the top cover (Figure 4-2) over the chassis so that the tabs along
the front of the cover align with the slots in the top edge of the chassis.
4. Slide the cover toward the front of the system so that the tabs firmly
engage in the slots in the chassis.
5. Attach the cover to the chassis with the three screws you removed
earlier, and tighten them firmly (6.0 inch-pounds).
6. Replace both side covers. Connect all external cables and power cords
to the system.
M440LX Server System Product Guide
83
Download from Www.Somanuals.com. All Manuals Search And Download.
Removing the Plastic Front Cover
See Figure 4-3.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Remove both side covers and the top cover, and set them aside
(page 80).
3. Remove the two screws from the front cover, and save them.
4. Unsnap the front cover from the chassis, and place it on a smooth
surface so that it doesn’t get scratched.
Replacing the Plastic Front Cover
See Figure 4-3.
1. Insert the plastic T-shaped tabs on the bottom front cover into the
T-shaped notches along bottom of the chassis. Then gently press the
cover onto the chassis until all tabs snap into place.
2. Attach the front cover to the chassis with the two screws you removed
earlier, and tighten them firmly (6.0 inch-pounds).
3. Replace the top cover and both side covers.
4. Connect all external cables and power cords to the system. (Some
systems have more than one power cord.)
84
Chapter 4 Working Inside Your System
Download from Www.Somanuals.com. All Manuals Search And Download.
1
2
3
OM05786
Figure 4-3. Plastic Front Cover
1
2
3
Screw
Plastic front cover
Plastic tab
M440LX Server System Product Guide
85
Download from Www.Somanuals.com. All Manuals Search And Download.
Removing the Snap-in Plastic Peripheral Bay Cover
See Figure 4-4.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Remove the right side cover (when viewed from the front, see page 80).
3. To remove the snap-in plastic peripheral bay cover, push up on the
bottom flexible tab below the 3.5-inch diskette drive. Then push the tab
toward the front of the system until you can grasp the lower right
corner of the cover.
CAUTION
!
▲
▲
Do not try to remove the snap-in peripheral bay cover by
inserting a screwdriver or other tool in the notch on the left
side of the cover. The cover may break.
4. Pull the lower right corner of the cover toward you with an upward
twisting motion to disengage the top flexible tab.
5. Remove the snap-in peripheral bay cover from the system, and place it
on a flat surface.
OM05778
Figure 4-4. Snap-in Plastic Peripheral Bay Cover
86
Chapter 4 Working Inside Your System
Download from Www.Somanuals.com. All Manuals Search And Download.
Replacing the Snap-in Plastic Peripheral Bay Cover
See Figure 4-4.
1. Insert the rigid tabs on the plastic snap-in peripheral bay cover into the
notches along the inside edge of the plastic front panel.
2. Push the top right corner of the plastic cover toward the chassis with an
inward twisting motion to insert the top flexible tab in the slot above the
3.5-inch diskette drive.
3. Gently press on the cover until both the top and bottom flexible tabs
snap into place.
4. Replace the right side cover (page 81).
5. Connect all external cables and power cords to the system. (Some
systems have more than one power cord.)
M440LX Server System Product Guide
87
Download from Www.Somanuals.com. All Manuals Search And Download.
Board Set
The system board supports two processor modules, a memory module, and
an RPX module.
CAUTION
!
▲
▲
The Pentium II processor is be extremely sensitive to ESD
and always requires careful handling. After removing the
module from its protective wrapper or from the system
board, place it heat sink side down on a nonconductive,
static-free surface. Do not slide the module over any
surface.
If you are upgrading a one-processor system with a second processor, you
must install a voltage regulator and remove the termination board from the
CPU1 slot.
Removing the Termination Board
See Figure 4-5.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Remove the left side cover (page 80).
3. Press the latches on the Terminator Latching Assembly (TLA) inward.
4. Pull the TLA out of the module retention bracket.
5. Holding the terminator board by its top edge, carefully rock it back and
forth until the edge connector pulls free.
88
Chapter 4 Working Inside Your System
Download from Www.Somanuals.com. All Manuals Search And Download.
A
B
C
OM05773A
Figure 4-5. Removing a Termination Board
A
B
C
Latch
Terminator Latching Assembly
Terminator Board
Installing a Voltage Regulator Module
See Figure 4-6.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Remove the left side cover (page 80).
3. Being careful not to touch the components or connector on the voltage
regulator module, remove it from its protective wrapper and place it on
a nonconductive, static-free surface.
4. Record the module ID information (may be a date code) in your
equipment log.
5. Hold the module by its top edge or upper corners and firmly press it
into the connector (Figure 4-6) on the system board until the lock tabs
click into place.
M440LX Server System Product Guide
89
Download from Www.Somanuals.com. All Manuals Search And Download.
3
2
1
OM05774
Figure 4-6. Installing a Voltage Regulator Module
1
2
3
Module
Connector
Lock Tab
90
Chapter 4 Working Inside Your System
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing a Pentium II Processor
See Figure 4-7.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Remove the left side cover (page 80).
3. Being careful not to touch the components or gold edge connectors on
the processor module, remove it from its protective wrapper and place
it heat-sink side down on a nonconductive, static-free surface.
4. Record the module serial number in your equipment log.
5. Press the locking tabs inward until they remain retracted.
6. Hold the module by its top edge or upper corners, and firmly press it
into the connector (Figure 4-7) on the system board. Press the locking
tabs outward so they engage the support bracket.
CPU1
CPU0
OM05775
Figure 4-7. Installing a Pentium II Processor
7. Replace the left side cover (page 81).
8. Run the SCU to configure the system. For information about running
the utility, see Chapter 3, "Configuring The System."
M440LX Server System Product Guide
91
Download from Www.Somanuals.com. All Manuals Search And Download.
Removing a Pentium II Processor
See Figure 4-7.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Remove the left side cover (page 80).
3. Squeeze the locking tabs and pull the module free from the connector.
4. Store the module in an antistatic protective wrapper, or place it
processor-side up on a nonconductive, static-free surface.
Installing the Memory Module
See Figure 4-8.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Remove the left side cover (page 80).
3. Remove the rail.
4. Being careful not to touch the components or gold edge connectors on
the memory module, remove it from its protective wrapper and place it
socket-side up on a nonconductive, static-free surface.
5. Record the module serial number in your equipment log.
6. Hold the module by its top edge or upper corners, and firmly press it
into the connector (Figure 4-8) on the system board.
7. Install the rail.
92
Chapter 4 Working Inside Your System
Download from Www.Somanuals.com. All Manuals Search And Download.
1
2
3
OM05760B
Figure 4-8. Installing the Memory Module
1
2
3
System board
Connector
Module
8. Run the SCU to configure the system. For information about running
the utility, see Chapter 3, "Configuring The System."
M440LX Server System Product Guide
93
Download from Www.Somanuals.com. All Manuals Search And Download.
Removing the Memory Module
See Figure 4-8.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Remove the left side cover (page 80).
3. Remove the rail.
4. Holding the module by its top edge or upper corners, carefully rock it
back and forth until the edge connector pulls free.
5. Store the module in an antistatic protective wrapper, or place it Socket
side up on a nonconductive, static-free surface.
6. Install the rail.
Installing the RPX Module
See Figure 4-9.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Remove the left side cover (page 80).
3. Remove the RPX rail.
4. Being careful not to touch the components or gold edge connectors on
the RPX module, remove it from its protective wrapper and place it
component side up on a nonconductive, static-free surface.
5. Record the module serial number in your equipment log.
6. Plug in the RPX battery.
7. Hold the module by its top edge or upper corners, and firmly press it
into the connector (Figure 4-9) on the system board.
8. Install the rail.
94
Chapter 4 Working Inside Your System
Download from Www.Somanuals.com. All Manuals Search And Download.
1
3
2
OM05760A
Figure 4-9. Installing the RPX Module
1
2
3
System board
Connector
Module
9. Run the SCU to configure the system. For information about running
the utility, see Chapter 3, "Configuring The System."
M440LX Server System Product Guide
95
Download from Www.Somanuals.com. All Manuals Search And Download.
Removing the RPX Module
See Figure 4-9.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Remove the left side cover (page 80).
3. Remove the RPX rail.
4. Holding the module by its top edge or upper corners, carefully rock it
back and forth until the edge connector pulls free.
5. Unplug the RPX battery.
6. Store the module in an antistatic protective wrapper, or place it
component side up on a nonconductive, static-free surface.
7. Install the rail.
96
Chapter 4 Working Inside Your System
Download from Www.Somanuals.com. All Manuals Search And Download.
Add-in Boards
The system board provides seven PCI bus master slots and three ISA bus
master slots. They accept any add-in PCI and ISA boards. One PCI
connector shares a common chassis I/ O expansion slot with an ISA
connector; you can use either PCI slot or ISA in the slot, but not both.
CAUTIONS
!
▲
▲
Do not overload the system board by installing add-in
boards that draw excessive current. For expansion slot
current limitations, see Chapter 7, “Power System.”
Add-in boards can be extremely sensitive to ESD and
always require careful handling. After removing the board
from its protective wrapper or from the system board, place
it component-side up on a nonconductive, static-free
surface. Do not slide the board over any surface.
Note
✏
If you are installing or removing an ISA add-in board, you
must run the SCU to reconfigure the system. Running the
SCU is optional for a PCI add-in board.
M440LX Server System Product Guide
97
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing an Add-in Board
See Figures 4-10, 4-11, and 4-12.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Remove the left side cover (page 80).
3. Remove and save the expansion slot screw and cover.
OM04638
Figure 4-10. Expansion Slot Cover
98
Chapter 4 Working Inside Your System
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Being careful not to touch the components or gold edge connectors on
the board, remove it from its protective wrapper and place it
component-side up on a nonconductive, antistatic surface.
5. Record the board serial number in your equipment log.
6. Set any jumpers or switches according to the board manufacturer's
instructions.
7. Hold the board by its top edge or upper corners, and firmly press it into
an expansion slot on the system board (Figure 4-11 or Figure 4-12). The
tapered foot of the board retaining bracket must fit into the mating slot
in the expansion slot frame.
8. Align the rounded notch in the retaining bracket with the threaded hole
in the expansion slot frame. The retaining bracket fits into the space
that was occupied by the slot cover.
9. Insert the screw you removed earlier, and push the rounded notch up
against the screw. Tighten the screw firmly (6.0 inch-pounds) to
prevent the bracket from interfering with an adjacent one.
10. Replace the left side cover (page 81).
11. If you installed an ISA add-in board, run the SCU to reconfigure the
system. Running the SCU is optional for a PCI add-in board. For
information about running this utility, see Chapter 3, “Configuring The
System.”
M440LX Server System Product Guide
99
Download from Www.Somanuals.com. All Manuals Search And Download.
OM04639
Figure 4-11. Installing an ISA Add-in Board, Component-side Up
100
Chapter 4 Working Inside Your System
Download from Www.Somanuals.com. All Manuals Search And Download.
OM04640
Figure 4-12. Installing a PCI Add-in Board, Component-side Down
M440LX Server System Product Guide
101
Download from Www.Somanuals.com. All Manuals Search And Download.
Removing an Add-in Board
CAUTION
!
▲
▲
Expansion slot covers must be installed on all vacant slots
to maintain the electromagnetic emissions characteristics of
the system and to ensure proper cooling of the system
components.
See Figures 4-10, 4-11, and 4-12.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Remove the side cover (page 80).
3. Disconnect any cables attached to the board you are removing.
4. Remove and save the add-in board retaining bracket screw.
5. Holding the board by its top edge or upper corners, carefully rock it
back and forth until the edge connector pulls free. Make sure that you
do not scrape the board against other components.
6. Store the board in an antistatic protective wrapper.
7. Install an expansion slot cover (Figure 4-10) over the vacant slot. The
tapered foot of the cover must fit into the mating slot in the bottom of
the expansion slot frame.
8. Insert the screw you removed earlier, and push the rounded notch up
against the screw. Tighten the screw firmly (6.0 inch-pounds) to
prevent the bracket from interfering with an adjacent one.
9. Replace the side cover (page 81).
10. If you removed an ISA add-in board, run the SCU to configure the
system. For information about running this utility, see Chapter 3,
“Configuring The System.”
102
Chapter 4 Working Inside Your System
Download from Www.Somanuals.com. All Manuals Search And Download.
Diskette Drive
The system comes with a 3.5-inch diskette drive installed in the vertical
3.5-inch peripheral bay.
Contact your sales representative or dealer for a list of approved add-in
peripheral devices.
Removing the Diskette Drive
See Figures 4-13 and 4-14.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Remove the right side cover (page 80).
3. Disconnect the power and signal cables from the diskette drive.
4. Remove the screw that secures the drive and carrier assembly to the
chassis, and set it aside.
5. Slide the assembly toward the top power supply to disengage the tabs
from the slots in the chassis wall.
6. Remove the assembly from the chassis, and place it bracket-side up on
an antistatic surface.
M440LX Server System Product Guide
103
Download from Www.Somanuals.com. All Manuals Search And Download.
1
2
3
4
OM05769
Figure 4-13. Removing the Diskette Drive
1
2
3
4
Signal cable
Power cable
Screw
Drive and carrier assembly
104
Chapter 4 Working Inside Your System
Download from Www.Somanuals.com. All Manuals Search And Download.
7. Remove the three screws, and set them and the drive carrier aside. See
Figure 4-14.
8. Place the drive in an antistatic protective wrapper.
9. Replace the right side cover (page 81).
1
2
3
OM05791
Figure 4-14. Diskette Drive and Carrier Assembly
1
2
3
Screw
Carrier
Diskette drive
Installing a Diskette Drive
See Figures 4-13 and 4-14.
1. Remove the 3.5-inch diskette drive from its protective wrapper, and
place it component-side up on an antistatic surface.
2. Record the drive model and serial number in your equipment log.
3. Set any jumpers or switches according to the drive manufacturer's
instructions.
M440LX Server System Product Guide
105
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Place the drive carrier on the component-side of the drive, and align the
three mounting holes.
5. Attach the carrier to the drive with three screws of the appropriate size
and length (not supplied), and tighten the screws firmly (between 4.0
and 6.0 inch-pounds).
6. Position the drive and carrier assembly over the slots in the chassis wall,
and slide the assembly toward the front of the system to engage its tabs
in the slots.
7. Secure the drive and carrier assembly to the chassis wall with the screw
you removed earlier; tighten the screw firmly (6.0 inch-pounds).
8. Connect the signal and power cables to the diskette drive. The red
stripe on the signal cable must face toward the center of the drive.
9. Replace the right side cover (page 81).
10. Run the SCU to specify that the diskette drive is installed in the system.
For information about running this utility, see Chapter 3, “Configuring
The System.”
5.25-inch Peripherals
The system comes with an IDE CD-ROM drive installed in the top 5.25-inch
peripheral bay.
The two 5.25-inch half-height bays below the CD-ROM drive provide space
for tape backup or other removable media devices.
To install devices in the 5.25-inch bays, you must remove the plastic filler
panels and stainless steel EMI shields that cover the bays.
Note
✏
We do not recommend mounting a hard disk drive in a
5.25-inch bay because the drive generates EMI, its
susceptibility to ESD increases, and it may not be
adequately cooled.
Contact your sales representative or dealer for a list of approved add-in
peripheral devices.
106
Chapter 4 Working Inside Your System
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing a 5.25-inch Peripheral Device
See Figures 4-15, 4-16, 4-17, and 4-18.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Remove both side covers and the top cover (page 80).
3. Remove the snap-in plastic peripheral bay cover (page 86), and place it
on a smooth surface so that it doesn’t get scratched.
4. Remove the screws and filler panel, and set them aside.
OM05315
Figure 4-15. Filler Panels
5. Push the tab on the left side of the EMI metal shield to the right to
disengage it from the chassis. Save the shield.
6. Remove the device from its packaging, and place it on an antistatic
surface.
7. Record the device model and serial number in your equipment log.
8. Set any jumpers and/ or switches on the device according to the
manufacturer’s instructions.
M440LX Server System Product Guide
107
Download from Www.Somanuals.com. All Manuals Search And Download.
OM04647
Figure 4-16. Removing the EMI Shield
9. Using two screws of the appropriate size and length (not supplied),
attach each plastic slide rail to the device.
108
Chapter 4 Working Inside Your System
Download from Www.Somanuals.com. All Manuals Search And Download.
4
1
OM04648
3
2
Figure 4-17. Snap-in Plastic Slide Rails
1
2
3
4
Tape drive or other device
Tab
Screw
Slide rail
10. Position the device so that the plastic slide rails on each side of it engage
in the bay guide rails. Push the device into the bay until the slide rails
lock in place.
M440LX Server System Product Guide
109
Download from Www.Somanuals.com. All Manuals Search And Download.
3
1
2
OM05789
Figure 4-18. Installing a 5.25-inch Peripheral Device
1
2
3
Tape drive or other device
Power cable
SCSI signal cable
11. Replace the snap-in plastic peripheral bay cover, top cover, and both
side covers.
12. This step is optional. If you installed a SCSI CD-ROM drive, run the
Symbios SCSI utility to enable BIOS support for a bootable CD-ROM.
Run the SCU or Setup to specify that the CD-ROM is the boot device.
For information about running these utilities, see Chapter 3,
“Configuring The System.”
110
Chapter 4 Working Inside Your System
Download from Www.Somanuals.com. All Manuals Search And Download.
Removing a 5.25-inch Peripheral Device
See Figures 4-15, 4-16, 4-17, and 4-18.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Remove both side covers and the top cover (page 80).
3. Remove the snap-in plastic peripheral bay cover (page 86), and place it
on a smooth surface so that it doesn’t get scratched.
4. Disconnect the power cable and the signal cable from the drive.
5. While squeezing the protruding plastic snap-in rails attached to the
drive toward each other, carefully slide the drive forward out of the
bay, and place it on an antistatic surface.
6. Remove and save the four screws and the two snap-in slide rails from
the device.
7. If you leave the bay empty, install a stainless steel EMI shield on the bay
and a filler panel on the snap-in plastic peripheral bay cover for proper
cooling and airflow.
8. Replace the snap-in plastic peripheral bay cover.
9. Replace the top cover and both side covers.
10. If you leave the bay empty, run the SCU to reconfigure the system. For
information about running this utility, see Chapter 3, “Configuring The
System.”
M440LX Server System Product Guide
111
Download from Www.Somanuals.com. All Manuals Search And Download.
Back-up Battery
The lithium battery on the system board powers the real-time clock (RTC)
for up to 10 years in the absence of power. The RTC contains 256 bytes of
general purpose RAM that stores the system BIOS configuration
information, clock registers, and general purpose control registers. When
the battery starts to weaken, it loses voltage, and the system settings stored
in CMOS RAM in the RTC (for example, the date and time) may be wrong.
Contact your sales representative or dealer for a list of approved
replacement devices and available service.
!
▲
WARNING
If the system has been running, any installed processor
and heat sink on the processor board(s) will be hot. To
avoid the possibility of a burn, be careful when removing
or installing system board components that are located
near processors.
The following warning and translations are required by specific certifying
agencies to be printed immediately adjacent to the procedure for removing
the real-time clock.
CAUTION
!
▲
▲
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type
recommended by the equipment manufacturer. Discard
used battery according to manufacturer's instructions.
ADVARSEL!
!
▲
▲
Lithiumbatteri - Eksplosionsfare ved fejlagtig håndtering.
Udskiftning må kun ske med batteri af samme fabrikat og
type. Levér det brugte batteri tilbage til leverandøren.
ADVARSEL
!
▲
▲
Lithiumbatteri - Eksplosjonsfare. Ved utskifting benyttes
kun batteri som anbefalt av apparatfabrikanten. Brukt
batteri returneres apparatleverandøren.
VARNING
!
▲
▲
Explosionsfara vid felaktigt batteribyte. Använd samma
batterityp eller en ekvivalent typ som rekommenderas av
apparattillverkaren. Kassera använt batteri enligt
fabrikantens instruktion.
112
Chapter 4 Working Inside Your System
Download from Www.Somanuals.com. All Manuals Search And Download.
VAROITUS
!
▲
▲
Paristo voi räjähtää, jos se on virheellisesti asennettu.
Vaihda paristo ainoastaan laitevalmistajan suosittelemaan
tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden
mukaisesti.
Replacing the Back-up Battery
See Figure 4-19.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Remove the left side cover (page 80).
3. Insert the tip of a small flat-bladed screw driver, or equivalent, under
the plastic tab on the snap-on plastic retainer. Gently lift up and pull
back on the retainer to remove it from the lithium battery socket.
4. Remove the battery from its socket.
5. Dispose of the lithium battery according to local ordinance.
6. Remove the new lithium battery from its package, and, being careful to
observe the correct polarity, insert it into the battery socket.
7. Install the snap-on plastic retainer on the socket.
8. Replace the left side cover (page 81).
9. Run the SCU to restore the configuration settings to the RTC. For
information about running this utility, see Chapter 3, “Configuring The
System.”
M440LX Server System Product Guide
113
Download from Www.Somanuals.com. All Manuals Search And Download.
2
1
3
OM05791A
Figure 4-19. Lithium Back-up Battery
114
Chapter 4 Working Inside Your System
Download from Www.Somanuals.com. All Manuals Search And Download.
Front Panel Board
The front panel board contains the system controls and indicators. It is
mounted on a snap-on standoff and a threaded standoff inside the chassis.
Removing the Front Panel Board
See Figure 4-20.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Remove both side covers and the top cover (page 80).
3. Remove the screw from the threaded standoff inside the chassis, and set
it aside. You will need the screw later.
4. Grasp the front panel board, and gently pull it toward the back of the
system until it clears the snap-on standoff.
5. Label and disconnect all the cables connected to the front panel board.
6. Remove the board from the system, and place it on an antistatic foam
pad or a grounded workstation.
Replacing the Front Panel Board
See Figure 4-20.
1. Place the front panel board on the chassis panel above the system board.
2. Reconnect the cables to the front panel board.
3. Carefully position the front panel board over the snap-on and threaded
standoffs inside the chassis.
4. Gently press the front panel board onto the snap-on standoff until it
snaps in place.
5. Replace and tighten firmly (6.0 inch-pounds) the screw that secures the
front panel board to the chassis.
6. Replace the top cover and the side covers (page 81).
M440LX Server System Product Guide
115
Download from Www.Somanuals.com. All Manuals Search And Download.
OM05268
Figure 4-20. Removing the Front Panel Board
116
Chapter 4 Working Inside Your System
Download from Www.Somanuals.com. All Manuals Search And Download.
Fans
The system contains up to three fans and two blowers for cooling and
airflow.
•
Located in the system board side of the system: some configurations
may have up to two fans and two blowers.
•
Located in the power supply side of the system: configurations with
only one or two power supplies also have a fan on the rear bulkhead.
Configurations with three supplies do not have this fan. The fans
integrated in the power supplies provide sufficient cooling and airflow.
Replace a failed fan with the same type, 92 mm with a tachometer signal, or
an approved fan. Replace a failed blower with the same type. See
Chapter 9, “I/ O Ports and Connectors.” Contact your sales representative
or dealer for a list of approved fans and blowers.
Removing a Front Panel Fan
See Figures 4-21 and 4-22.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Remove the left side cover (page 80).
3. Depending on which fan you are removing, disconnect the fan power
cable connector from the fan header, Fan 3 or Fan 4, on the system
board.
4. Press the left outer flexible tab on the plastic housing and fan assembly
toward the fan until you can pull the tab through the slot in the chassis.
5. Pull the assembly toward you, remove it from the chassis, and place it—
fan-side up—on a flat surface.
M440LX Server System Product Guide
117
Download from Www.Somanuals.com. All Manuals Search And Download.
OM05278
Figure 4-21. Front Panel Fans
118
Chapter 4 Working Inside Your System
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Remove the fan from the plastic housing by pushing the inner flexible
tabs on the housing away from the fan. Save the housing.
OM05277
Figure 4-22. Front Fan Assembly
M440LX Server System Product Guide
119
Download from Www.Somanuals.com. All Manuals Search And Download.
Replacing a Front Panel Fan
See Figures 4-21 and 4-22.
Note
✏
The front panel fans pull air from in front of the chassis so
that it flows across the boards and out the back. Thus, the
fans must be oriented for the correct airflow direction. If
you place the fan so the label faces the back of the chassis,
this should provide the correct orientation. You can
confirm this by checking the embossed arrows on the side
of the fan as you place it in its bracket:
⇒
⇑
Arrow points horizontally toward back of chassis
Arrow points vertically up
1. Place the plastic housing—flexible tabs facing up—on a flat surface.
2. With the power cable side of the fan facing down, place it inside the
plastic housing. Route the cable through the slot in the side of the
housing.
3. Press down on the fan until the inner flexible plastic tabs on the housing
snap into place on the fan. Make sure you do not pinch the cable
between the housing and the fan.
4. Position the plastic housing and fan assembly inside the chassis in front
of the card guide, and align the tabs with the slots in the front of the
chassis.
5. Insert the right flexible tab through the right slot in the front of the
chassis. Then press the left flexible tab through the left slot until it
snaps into place.
6. Connect the fan power cable connector to the fan header on the system
board. The bottom fan connects to connector Fan 2 and the top one
connects to connector Fan 4.
7. Replace the left side cover (page 81).
Removing the Fan Below the Top Power Supply
See Figures 4-23 and 4-24. The arrow on the fan indicates the direction of
airflow. The fan pulls air through the hot-docking bays and exhausts it out
of the system.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
120
Chapter 4 Working Inside Your System
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Remove both side covers and the top cover (page 80).
3. Disconnect the fan power cable connector from the fan header on the
hot-docking backplane.
4. Press the top outer flexible tab on the plastic housing and fan assembly
toward the fan until you can pull the tab through the slot in the chassis.
5. Pull the top of the assembly toward the hot-docking bays to disengage
the bottom flexible tab.
6. Remove the assembly from the chassis, and place it—fan-side down—
on a flat surface.
OM05767
Figure 4-23. Fan Below the Top Power Supply
M440LX Server System Product Guide
121
Download from Www.Somanuals.com. All Manuals Search And Download.
7. Remove the two screws that attach the finger guard to the fan. Set the
screws and finger guard aside.
8. Place the assembly—fan-side up—on a flat surface. Remove the fan
from the plastic housing by pushing the inner flexible tabs on the
housing away from the fan. Save the housing.
OM05325
Figure 4-24. Rear Fan Assembly
122
Chapter 4 Working Inside Your System
Download from Www.Somanuals.com. All Manuals Search And Download.
Replacing the Fan Below the Power Supply
See Figures 4-23 and 4-24. The arrow on the fan indicates the direction of
airflow. The fan pulls air through the hot-docking bays and exhausts it out
of the system.
1. Place the plastic housing—flexible tabs facing up—on a flat surface.
2. With the power cable side of the fan facing up, place it inside the plastic
housing. Route the cable through the slot in the side of the housing.
3. Press down on the fan until the inner flexible plastic tabs on the housing
snap into place on the fan. Make sure you do not pinch the cable
between the housing and the fan.
4. Place the assembly—fan-side down—on a flat surface. Attach the finger
guard to the fan with the screws you removed earlier.
5. Position the plastic housing and fan assembly inside the chassis below
the top power supply, and align the tabs with the slots in the back of the
chassis.
6. Insert the bottom flexible tab through the bottom slot in the back of the
chassis. Then press the top flexible tab through the top slot until it
snaps into place.
7. Connect the fan power cable connector to the fan header on the
hot-docking backplane.
8. Replace the top cover and both side covers (page 80).
M440LX Server System Product Guide
123
Download from Www.Somanuals.com. All Manuals Search And Download.
Power System
The system may be configured with one, two, or three 360 watt power
supplies.
•
•
•
•
One power supply.
Two power supplies and a power share board.
Two power supplies without a power share board.
Three power supplies and a power share board.
If a single power supply fails in a system with a power share board, the
yellow power supply failure LED on the front panel starts flashing.
Generally, a failed power supply can be replaced while the system is
running.
Removing a Power Supply
See Figure 4-25.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Unplug the AC power cord from the power supply.
3. Remove the screws that attach the power supply to the chassis, and set
them aside.
4. Slide the defective power supply out the back of the chassis.
124
Chapter 4 Working Inside Your System
Download from Www.Somanuals.com. All Manuals Search And Download.
OM05765
Figure 4-25. Removing a Power Supply
Replacing a Power Supply
See Figure 4-25.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Slide the power supply through the back of the system.
3. Attach the power supply to the system chassis with the four screws you
saved. Tighten the screws firmly (6.0 inch-pounds).
M440LX Server System Product Guide
125
Download from Www.Somanuals.com. All Manuals Search And Download.
Power Share Backplane
The power share backplane distributes the power load of the system among
two or three power supplies. The backplane is mounted on two snap-on
standoffs and six threaded standoffs on the center wall inside the chassis.
!
▲
WARNINGS
The power button on the front panel of the system does
not turn off the AC power. To remove AC power from the
system, you must unplug the AC power cord from each
power supply or wall outlet.
Hazardous voltage, current, and energy levels are present
inside the power share backplane. There are no user
serviceable parts inside it; servicing should be done only
by technically qualified personnel.
Removing the Power Share Backplane
See Figures 4-26 and 4-27.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Unplug the AC power cord from each power supply or wall outlet.
3. Remove the right side cover (page 80).
4. Label and disconnect the power and signal cables from the power share
backplane.
5. Remove the power supplies.
6. Remove the screws that attach the backplane to the threaded stand-offs
on the inside chassis wall, and set them aside.
7. Pull the backplane toward you to unsnap it from the snap-on standoffs.
8. Remove the backplane from the system, and set it aside.
126
Chapter 4 Working Inside Your System
Download from Www.Somanuals.com. All Manuals Search And Download.
OM05771
Figure 4-26. Removing the Power Share Backplane
M440LX Server System Product Guide
127
Download from Www.Somanuals.com. All Manuals Search And Download.
9
8
1
7
6
5
2
4
3
OM05770
Figure 4-27. Power Share Backplane Connectors
1
2
3
4
5
6
7
8
9
Input from top power supply
Input from middle power supply if present
Input from bottom power supply if present
Factory configured jumper
Nonremovable cover
Output to system peripherals
Cable tie-down
Output to auxiliary power connector on system board
Output to system board
128
Chapter 4 Working Inside Your System
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the Power Share Backplane
See Figures 4-26 and 4-27.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Remove the right side cover (page 80).
3. Position the mounting holes in the power share backplane over the
snap-in standoffs and threaded standoffs on the inside chassis wall.
4. Push the backplane toward the chassis wall until it snaps onto the
snap-in standoffs.
5. Insert the screws through the mounting holes in the backplane and into
the threaded stand-offs on the inside chassis wall; tighten the screws
firmly (6.0 inch-pounds).
6. Replace the power supplies.
7. Connect the power and signal cables to the power share backplane.
8. Replace the side cover (page 80).
M440LX Server System Product Guide
129
Download from Www.Somanuals.com. All Manuals Search And Download.
SCSI Hot-docking Backplane
The system may be configured with one or two SCSI hot-docking
backplanes.
Removing a Hot-docking Backplane
See Figure 4-28.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Remove all the hard disk drives from the hot-docking bay. See
Chapter 5, “SCSI Backplane and Drives: Hot-swapping and
Configuring.” Label each drive so that you can install them in the same
place.
3. Remove the right side cover (page 80).
4. Label and disconnect the power and signal cable connectors from the
hot-docking backplane. And, if present, disconnect the auxiliary fan
connector.
5. Remove the four screws that attach the backplane to the back of the
hot-docking bay, and set them aside.
6. Remove the backplane from the system, and place it on an antistatic
surface.
Installing a Hot-docking Backplane
See Figure 4-28.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Slide the hot-docking backplane into the notches in the metal tabs on the
back of the bay.
3. Position the screw holes in the backplane over the stand offs on the back
of the bay.
4. While holding the backplane in place, insert the four screws through the
holes in the backplane and into the standoffs. Tighten the screws firmly
(6.0 inch-pounds).
5. Connect the power and signal cables to the hot-docking backplane.
6. Install the hard disk drives in the hot-docking bay. See Chapter 5,
“SCSI Backplane and Drives: Hot-swapping and Configuring .” Make
sure you install the drives in the same places you removed them from.
7. Replace the right side cover (page 81).
130
Chapter 4 Working Inside Your System
Download from Www.Somanuals.com. All Manuals Search And Download.
3
4
2
1
5
6
OM05269
Figure 4-28. Removing a Hot-docking Backplane
1
2
3
Fan cable if present
Peripheral power connector
Peripheral power connector
4
5
6
Front panel cable
SCSI signal cable
Notch in metal tab
■ ■ ■
■ ■ ■
M440LX Server System Product Guide
131
Download from Www.Somanuals.com. All Manuals Search And Download.
132
Chapter 4 Working Inside Your System
Download from Www.Somanuals.com. All Manuals Search And Download.
SCSI Backplane and Drives:
Hot-swapping and Configuring
5
This chapter tells how to configure the SCSI backplane and install hot-swap
SCSI hard disk drives.
Warnings and Cautions
Before you remove the system covers to work inside it, observe the
warnings and cautions provided for your safety on page 3, “Safety
Guidelines.”
System integration should be done by technically qualified personnel.
Tools and Supplies You Need
•
•
•
•
Phillips (cross-head) screwdriver (#1 bit and #2 bit)
Jumper removal tool
Pen or pencil
Antistatic wrist strap (recommended)
Hot-docking Bays
The plastic front door covers a removable metal door that is secured to the
chassis with two screws. Plastic drive carriers for 3.5-inch wide by 1-inch
high drives allow easy hot-swapping of drives without shutting down the
system.
The upper and lower bay each have a separate backplane. Each backplane
uses industry standard 80-pin SCA connectors to support up to five
industry standard wide/ fast-20 SCSI III SCA hard disk drives. The bays
accept peripherals that consume up to 11 watts of power and run at a
maximum ambient temperature of 65 °C.
By installing an RPX board and appropriate software on the system board
and SCSI hard disk drives in the hot-docking bays, you can easily set up
Redundant Array of Inexpensive Disks (RAID) applications.
M440FX Server System Product Guide
133
Download from Www.Somanuals.com. All Manuals Search And Download.
SCSI Hard Disk Drive
The system supports a variety of single-ended SCSI SCA devices. As
shipped from the supplier, the system might not contain any hard disk
drives.
Contact your sales representative or dealer for a list of approved
single-ended SCSI SCA devices.
!
▲
WARNING
The single-ended SCSI hot-docking backplane requires
installing single-ended SCSI devices in your system.
Installing differential SCSI drive types can result in
electrical damage to the system board and the peripherals.
CAUTION
!
▲
▲
LECTROSTATIC DISCHARGE
E
AND
PROTECTION
ESD :
(ESD)
ESD can damage disk drives, add-in boards, and other
components. This server can withstand normal levels of
environmental ESD while hot-swapping SCSI hard disk
drives. However, we recommend doing all procedures in
this manual only at an ESD workstation. If one is not
available, you can provide some ESD protection by wearing
an antistatic wrist strap attached to chassis ground of the
server—any unpainted metal surface—when handling
components.
134
Chapter 5 SCSI Backplane and Drives: Hot-swapping and Configuring
Download from Www.Somanuals.com. All Manuals Search And Download.
Mounting a SCSI SCA Hard Disk Drive in a Plastic Carrier
See Figure 5-1.
1. Remove the 3.5-inch hard disk drive from its protective wrapper, and
place it on an antistatic surface.
2. Record the drive model and serial number in your equipment log.
3. Orient the drive so the connector is near the top surface of the drive,
and place it on an antistatic surface.
4. Place the plastic carrier on top of the drive.
5. Using four screws of the appropriate size and length (not supplied),
attach the carrier to the drive.
OM05787
Figure 5-1. Hard Disk Drive and Plastic Carrier
M440FX Server System Product Guide
135
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing a SCSI SCA Hard Disk Drive in a Hot-docking Bay
See Figure 5-2.
1. Open the plastic front door.
2. If you installed a padlock on the metal door to the hot-docking bays,
unlock the padlock and remove it.
3. Loosen the two spring-loaded, captive screws that secure the metal
door to the chassis, and open the door.
4. Position the plastic carrier, locking tab up, and drive assembly so it
engages the hot-docking bay guide rails.
5. Gently push the drive into the bay until it docks with the backplane
connector and snaps into place.
6. Gently close the metal door, and secure it to the chassis with the two
captive screws.
7. For security and to prevent unauthorized access to the bays, insert a
padlock through the metal door and chassis and lock it.
8. Close the lower plastic front door.
9. If you installed an RPX board in the system, run the Disk Array
Controller Configuration utility supplied with the board. See the
documentation provided with the board.
136
Chapter 5 SCSI Backplane and Drives: Hot-swapping and Configuring
Download from Www.Somanuals.com. All Manuals Search And Download.
1
2
OM06470
Figure 5-2. Installing a Hard Disk Drive
M440FX Server System Product Guide
137
Download from Www.Somanuals.com. All Manuals Search And Download.
Hot-swapping a SCSI SCA Hard Disk Drive
A bank of 10 yellow LEDs on the front panel monitors the drive status of
each drive in the upper and lower hot-docking bays. When a yellow LED is
on continuously, it is okay to hot-swap (replace) a bad drive with a good
one. You do not need to shut the system down to hot-swap a drive.
See Figure 5-2.
1. Open the plastic front door of the system.
2. If you installed a padlock on the metal door to the bays, unlock the
padlock and remove it.
3. Loosen the two captive, spring loaded screws securing the metal door
to the chassis, and open the door.
4. Check the two banks of yellow LEDs on the front panel to determine
which drive is bad. Grasp the plastic drive carrier and pull it toward
you to disengage the drive connector from the backplane connector.
5. Squeeze the tabs on the carrier toward each other, and carefully slide
the bad drive forward out of the bay. Place the drive on an antistatic
surface.
6. Position the new plastic carrier and drive assembly so that it engages
the bay guide rails.
7. Gently push the drive into the bay until it docks with the backplane
connector and snaps into place.
8. Gently close the metal door, and secure it to the chassis with the two
captive, spring loaded screws.
9. For security and to prevent unauthorized access to the bays, insert a
padlock through the metal loop protruding through the door and lock
it.
10. Close the lower plastic front door of the system.
138
Chapter 5 SCSI Backplane and Drives: Hot-swapping and Configuring
Download from Www.Somanuals.com. All Manuals Search And Download.
SCSI Hot-docking Backplane
The hot-docking backplane provides the following:
•
•
Five SCA connectors for SCA-compatible SCSI drives
Power control for each drive, including automatic slot-power-down
upon removing a drive
•
•
•
•
Signal for a fault indicator on the front panel for each drive
Internal I2C bus
+12 V connector for a fan with tachometer
Local I2C-based temperature sensor
The SCSI hot-docking backplane provides control signals and power for five
wide/ fast 3.5-inch SCA SCSI hard disk drives. The backplane receives
control signals from the Symbios SCSI controller on the system board
through a cable connected to the wide SCSI connector on the backplane.
The backplane gets power from the power system through cables connected
to the two power connectors.
The drives get their control signals and power from the SCA connectors on
the backplane.
The fault indicators on the front panel indicate failure status for each drive
in the bay. These indicators get their signals through a cable connected to
the front panel connector on the backplane.
The temperature sensor on the backplane provides temperature information
to other devices in the system through enclosure service messages.
The backplane power control provides powering down of a drive when a
failure is detected and reported to the SCSI bus. When a new drive is
inserted, the power control waits a short time for the drive to become fully
seated and then applies power to the drive.
Configuration Options
The hot-docking backplane contains only one configuration jumper: J8, the
internal/ external jumper.
A jumper is a small plastic-encased conductor—shorting plug—that slips
over two jumper pins.
M440FX Server System Product Guide
139
Download from Www.Somanuals.com. All Manuals Search And Download.
Internal/External (INT/EXT) Jumper J8
When this jumper is in the “INT” position—jumper on pins 1 and 2 default
setting—the backplane assumes it is operating in an “internal” peripheral
bay in the chassis.
When this jumper is in the “EXT” position—jumper on pins 2 and 3—the
backplane assumes it is operating in an “external” peripheral bay in a
peripheral expansion chassis. This option is not available.
SCSI ID Configuration Options
The SCSI chip on the hot-docking backplane uses the SAF-TE protocol to
communicate with the system board. This chip uses SCSI ID 6; therefore,
other SCSI devices cannot use this address.
J10
2-3
1-2
2-3
1-2*
J9
Drive 0 Drive 1 Drive 2 Drive 3 Drive 4
2-3
2-3
1-2
1-2*
ID8
ID0
ID8
ID0
ID9
ID1
ID9
ID1
ID2
ID11
ID3
ID12
ID4
ID2
ID10
ID10
ID11
ID3
ID12
ID4
* Jumper default setting.
140
Chapter 5 SCSI Backplane and Drives: Hot-swapping and Configuring
Download from Www.Somanuals.com. All Manuals Search And Download.
Changing SCSI Device ID Addresses
If you have a wide SCSI device ID conflict, you can resolve it by changing
the default ID addresses of the drives in the hot-docking bays. See the
jumper table on page 140.
See Figure 5-3.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Turn the system off with system power push-button on/ off switch on
the front panel, and unplug each AC power cord from the power supply
or wall outlet.
3. Remove the right side cover as described in Chapter 4, “Working Inside
Your System.”
4. The jumpers are parallel with the backplane surface as shown in
Figure 5-3. Looking into the right side of the system, between the back
of the bay and the backplane, J10 is the top jumper and J9 is the next one
down. To remove a jumper, use a jumper removal tool.
5. To install a jumper, position it over the two pins for the desired setting
and press down firmly. Be careful not to bend the pins.
6. Replace the right side cover as described in Chapter 4, "Working Inside
Your System."
7. Plug the AC power cord of each power supply into a separate wall
outlet on a dedicated AC branch circuit to avoid overloading a single
branch circuit.
M440FX Server System Product Guide
141
Download from Www.Somanuals.com. All Manuals Search And Download.
9
8
7
6
5
4
3
2
1
J10
J9
1
2
3
1
2
3
J8
1
2
3
J7
1
2
3
OM05270
Figure 5-3. SCSI Backplane
1
SCSI ID B, J10
SCSI ID A, J9
Internal/external, J8
Normal operation, J7
SCSI drive 4
SCSI drive 3
SCSI drive 2
SCSI drive 1
SCSI drive 0
2
3
4
5
6
7
8
9
142
Chapter 5 SCSI Backplane and Drives: Hot-swapping and Configuring
Download from Www.Somanuals.com. All Manuals Search And Download.
SCSI Hot-docking Backplane Connectors
Wide/Fast SCSI 16-Bit Connector
1
68
OM03878
Pin
Signal
Pin
Signal
1-16
17
GND (ground)
TERMPWR
TERMPWR
RESERVED
GND (ground)
DB 12_L
DB 13_L
DB 14_L
DB 15_L
DB P1_L
DB 0_L
49-50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
GND (ground)
TERMPWR
TERMPWR
RESERVED
GND (ground)
ATN_L
18
19
20-34
35
36
GND (ground)
BSY_L
37
38
ACK_L
39
RST_L
40
MSG_L
41
DB 1_L
SEL_L
42
DB 2_L
CD_L
43
DB 3_L
REQ_L
44
DB 4_L
I/O_L
45
DB 5_L
DB 8_L
46
DB 6_L
DB 9_L
47
DB 7_L
DB 10_L
DB 11_L
48
DB P_L
M440FX Server System Product Guide
143
Download from Www.Somanuals.com. All Manuals Search And Download.
Wide/Fast SCA2 SCSI 16-Bit Connectors
1
OM04855
Pin
Signal
Pin
Signal
1-4
5−6
7
+12 V
25
DB 3_L
NC
26
DB 2_L
DB 11_L
DB 10_L
DB 9_L
DB 8_L
I/O_L
27
DB 1_L
8
28
DB 0_L
9
29
DB P_L
DB 15_L
DB 14_L
DB 13_L
DB 12_L
+5 V
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
30
31
REQ_L
C/D_L
32
33
SEL_L
MSG_L
RST_L
ACK_L
BSY_L
ATN_L
DB P_L
DB 7_L
DB 6_L
DB 5_L
DB 4_L
34-36
37
SYNC
38
MTRON_L
ID0_L
39
40
ID2_L
41
DRV PRES_L
GND
42−76
77
LEDC, DRV ACT_L
DLYDST_L
ID1_L
78
79
80
ID3_L
144
Chapter 5 SCSI Backplane and Drives: Hot-swapping and Configuring
Download from Www.Somanuals.com. All Manuals Search And Download.
Power Connectors
The backplane power connectors are 4-pin shrouded plastic connectors with
mechanical keying.
1 2 3 4
OM04656
Pin
1
Signal
+12 V
Ground
Ground
+5 V
2
3
4
Fan Connector
This connector provides power to the fan below the top power supply.
1 2 3
OM05211
Pin
1
Signal
GND (ground)
Fan sense
+12 V
2
3
M440FX Server System Product Guide
145
Download from Www.Somanuals.com. All Manuals Search And Download.
Front Panel Connector
The front panel connector and cable provide the chassis-wide I2C bus and
the electrical path between the drive fault indicators (LEDs) and the SCSI
backplane that controls them.
1
OM04669
Pin
1
Name
Description
GND
Electrical ground (0V)
2
I2C_SDA
GND
I2C SDA (Serial Data)
3
Electrical ground (0V)
4
I2C_SCL
RFU
I2C Serial Clock
5
Reserved for future use
6
FAULT1_L
FAULT2_L
FAULT3_L
FAULT4_L
FAULT5_L
Fault signal for drive 1 (logical drive 0)
Fault signal for drive 2 (logical drive 1)
Fault signal for drive 3 (logical drive 2)
Fault signal for drive 4 (logical drive 3)
Fault signal for drive 5 (logical drive 4)
7
8
9
10
■ ■ ■
■ ■ ■
146
Chapter 5 SCSI Backplane and Drives: Hot-swapping and Configuring
Download from Www.Somanuals.com. All Manuals Search And Download.
Server Resources 6
This chapter tells how to upgrade the resources available in your system.
Warnings and Cautions
Before you remove the covers, observe the warnings and cautions provided
for your safety on page 3, “Safety Guidelines.”
System integration should be done by technically qualified personnel.
Tools and Supplies You Need
•
•
•
•
•
•
•
•
•
Phillips (cross-head) screwdriver (#1 bit and #2 bit)
Needle-nosed pliers
Small flat-bladed screwdriver
Jumper removal tool
Tweezers
IC removal tool for removing video memory DRAM
Antistatic wrist strap (recommended)
Rubber gloves
Pen or pencil
M440LX Server System Product Guide
147
Download from Www.Somanuals.com. All Manuals Search And Download.
Memory Module Resources
The memory module contains eight DIMM sockets for installing memory. It
supports from 16 MB to 1 GB of EDO ECC 3.3 V 60 ns DRAM, mounted on
JEDEC DIMMs. You may install mixed sizes and types of DIMMs in the
eight memory banks; however, their speeds must be the same. Always
install the DIMMs in sequence by starting with bank 0 (socket J1, closest to
the system board), then bank 1 (socket J2), and so on with bank 7 (socket J8)
as the last one.
To avoid potential memory problems, use only DIMMs from JEDEC-
compatible manufacturers that have been tested for compatibility with the
memory module. Contact your sales representative or dealer for a list of
approved DIMMs.
ECC memory detects and corrects single-bit errors from DRAM in real time,
allowing your system to function normally. It detects all double-bit errors
but does not correct them; it also detects all three-bit and four-bit adjacent
errors in a DRAM nibble but does not correct them. When one of these
multiple-bit errors occurs, the PMC generates an SERR (system error) which
usually halts the system. ECC is calculated on a 64 bit wide memory basis.
The system supports both base (conventional) and extended memory. Base
memory is located at addresses 00000h to 9FFFFh (the first 640 KB).
Extended memory begins at address 0100000h (1 MB) and extends to
FFFFFFFFh (4 GB), which is the limit of addressable memory. The top of
physical memory is a maximum of 1 GB.
Some operating systems and application programs use base memory; for
example, MS-DOS, OS/ 2†, and UNIX. Other operating systems use both
conventional and extended memory; for example, OS/ 2 and UNIX.
MS-DOS does not use extended memory; however, some MS-DOS utility
programs such as RAM disks, disk caches, print spoolers, and windowing
environments use extended memory for better performance.
148
Chapter 6 Server Resources
Download from Www.Somanuals.com. All Manuals Search And Download.
DIMM 0, J1
DIMM 1, J2
DIMM 2, J3
DIMM 3, J4
DIMM 4, J5
DIMM 5, J6
DIMM 6, J7
DIMM 7, J8
OM05785A
Figure 6-1. Memory Module
M440LX Server System Product Guide
149
Download from Www.Somanuals.com. All Manuals Search And Download.
Memory Regions
The memory module supports from 16 MB to 1 GB of ECC memory by
using fast page mode (FPM) or extended data out (EDO) 64 Mbit DRAMs
mounted on JEDEC 3.3 V 60 ns DIMMs.
DOS Compatibility Region
The DOS compatibility region covers 1 MB of memory from addresses
0000_0000h to 000F_FFFFh.
Address Range (hex)
Amount
512 KB
128 KB
128 KB
128 KB
64 KB
Function
0000_0000h–0007_FFFFh
0008_0000h–0009_FFFFh
000A_0000h–000B_FFFFh
000C_0000h–000D_FFFFh
000E_0000h–00EF_FFFFh
000F_0000h–000F_FFFFh
DOS region, base system memory (fixed)
ISA window memory
PCI/ISA Video or SMM
Add-in card BIOS and buffer area
Extended system BIOS
System BIOS
64 KB
Extended Memory Region
The extended memory region covers 4 GB of memory from addresses
010_0000h to FFFF_FFFFh.
Address Range (hex)
Amount
1 GB
Function
0100_0000h–3FFF_FFFFh
3FFF_0000h–FFFF_FFFFh
Local DRAM space
PCI memory space
3 GB
150
Chapter 6 Server Resources
Download from Www.Somanuals.com. All Manuals Search And Download.
ECC Memory
Table 6-1. ECC Memory Banks
If you fill one bank with
8 MB DIMM, 1M x 72
16 MB DIMM, 2M x 72
32 MB DIMM, 4M x 72
64 MB DIMM, 8M x 72
128 MB DIMM, 16M x 72
Memory size for that bank will be
8 MB
16 MB
32 MB
64 MB
128 MB
Table 6-2. Sample DIMM Size Combinations
Banks Filled
0, J1 1, J2 2, J3 3, J4 4, J5 5, J6 6, J7 7, J8 Total Memory
8
8 MB
24 MB
8
16
32
32
64
16
16
64
16
16
32
64
8
8
56 MB
8
8
64 MB
64
32
16
64
128 128
416 MB
32
32
64
8
128
64
280 MB
64
64
128 128 456 MB
64
64
64
64
512 MB
128 128 128 128 128 128 128 128 1024 MB
M440LX Server System Product Guide
151
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing DIMMs
CAUTIONS
!
▲
▲
Use extreme care when installing a DIMM. Applying too
much pressure can damage the socket slot. DIMMs are
keyed and can be inserted in only one way.
Mixing dissimilar metals may cause failures. Install DIMMs
with gold-lead alloy plated edge connectors only in
gold-lead alloy plated sockets.
See Figures 6-2 and 6-3.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Remove the left side cover and memory module as described in
Chapter 4, "Working Inside Your System."
3. Hold the module only by its edges, being careful not to touch its
components or gold edge connectors, and place it processor-side up on
an antistatic surface.
4. Remove a DIMM from its antistatic package by holding the DIMM only
by its edges.
5. Beginning with bank 0 (Figure 6-2), socket J1, orient the DIMM so that
the two notches in the bottom edge of it align with the keyed DIMM
socket.
6. Insert the bottom edge of the DIMM into socket J1, and press down
firmly on the DIMM until it seats correctly (Figure 6-3).
152
Chapter 6 Server Resources
Download from Www.Somanuals.com. All Manuals Search And Download.
2
1
DIMM 0, J1
DIMM 1, J2
DIMM 2, J3
DIMM 3, J4
DIMM 4, J5
DIMM 5, J6
DIMM 6, J7
DIMM 7, J8
OM05784A
Figure 6-2. DIMM Orientation
1
2
3
4
5
6
7
8
9
Bank 0, J1
Bank 1, J2
Bank 2, J3
Bank 3, J4
Bank 4, J5
Bank 5, J6
Bank 6, J7
Bank 7, J8
Ejector lever
M440LX Server System Product Guide
153
Download from Www.Somanuals.com. All Manuals Search And Download.
7. Gently push the plastic ejector levers (Figure 6-3) on the socket ends to
the upright position.
OM05273
Figure 6-3. Properly Seated DIMM
8. Repeat the above steps to install more DIMMs. Always install them in
sequence by installing the next DIMM in bank 1, socket J2, and so on
with the last one in bank 7, socket J8.
9. Install the memory module and the left side cover as described in
Chapter 4, "Working Inside Your System."
10. Connect all external cables and the power cord(s) to the system.
11. Turn on the monitor and then the system.
12. Run the System Configuration Utility (SCU) to configure the system and
to properly attribute ECC memory. Failure to do so may degrade the
performance of your system. For information about running the SCU,
see Chapter 3, "Configuring The System."
154
Chapter 6 Server Resources
Download from Www.Somanuals.com. All Manuals Search And Download.
Removing DIMMs
See Figure 6-4.
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Remove the left side cover and memory module as described in
Chapter 4, "Working Inside Your System."
3. Hold the module only by its edges, being careful not to touch its
components or gold edge connectors, and place it on an antistatic
surface.
4. Starting with the first DIMM-filled socket closest to the top edge of the
module, remove the DIMMs one at a time.
CAUTION
!
▲
▲
Use extreme care when removing a DIMM. Too much
pressure can damage the socket slot. Apply only enough
pressure on the plastic ejector levers to release the DIMM.
5. Gently push the plastic ejector levers out and down to eject the DIMM
from its socket (Figure 6-4).
6. Carefully lift the DIMM away from the socket and store it in an
antistatic package.
7. Repeat the above steps to remove other DIMMs.
M440LX Server System Product Guide
155
Download from Www.Somanuals.com. All Manuals Search And Download.
OM05275
Figure 6-4. Removing ECC Memory DIMMs
8. Install the memory module and the left side cover and as described in
Chapter 4, "Working Inside Your System."
9. Connect all external cables and the power cord(s) to the system.
10. Turn on the monitor and then the system.
11. Run the System Configuration Utility (SCU) to configure the system and
to properly attribute ECC memory. Failure to do so may degrade the
performance of your system. For information about running the SCU,
see Chapter 3, "Configuring The System."
156
Chapter 6 Server Resources
Download from Www.Somanuals.com. All Manuals Search And Download.
System Board Resources
Video Memory DRAM
The system board comes with 512 KB of onboard video memory. Increasing
the video memory buffer size to 1 MB with a 40-pin 256 K x 16, 60 ns
fast-page DRAM allows the controller to support 132-column text modes
and high resolution graphics with 1280 x 1024 x 16 colors. Depending on
the environment, the controller displays up to 64,000 colors in some video
resolutions.
Note
✏
DRAMs from only certain manufacturers have been tested
for compatibility with the system. Contact your dealer or
sales representative for a list of approved manufacturers
and their devices.
Installing the Video Memory DRAM
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Remove the left side cover as described in Chapter 4, "Working Inside
Your System."
3. Remove the 256 K x 16, 60 ns DRAM from its protective package, and
align the dot on the DRAM with the beveled end of socket U25
(Figure 6-5) on the system board.
4. Press the DRAM down firmly until it is fully seated in the socket.
5. Replace the left side cover as described in Chapter 4, "Working Inside
Your System."
Removing the Video Memory DRAM
1. Observe the warnings and cautions on page 3, “Safety Guidelines.”
2. Remove the left side cover as described in Chapter 4, "Working Inside
Your System."
3. Using an IC removal tool, remove the video memory DRAM from
socket U7C1 (Figure 6-5) on the system board, place it on a conductive
foam pad, and store it in an antistatic protective package.
4. Replace the left side cover as described in Chapter 4, "Working Inside
Your System."
M440LX Server System Product Guide
157
Download from Www.Somanuals.com. All Manuals Search And Download.
U7C1
OM05781
Figure 6-5. Video Memory DRAM
!
▲
WARNING
Installing the video DRAM chip incorrectly in the socket
could produce an extremely high case temperature,
destroy the chip, and possibly the system board. Do not
touch the chip after such an occurrence until you
determine that the case is not at an elevated temperature.
158
Chapter 6 Server Resources
Download from Www.Somanuals.com. All Manuals Search And Download.
I/O Addresses and Resources
The I/ O map in the following table shows the location in I/ O space of all
directly I/ O accessible registers.
Address
Resource
0000h–000Fh
0020h–0021h
002Eh–002Fh
0040h–0043h
0060h, 0064h
0061h
DMA Controller 1
Interrupt Controller 1
Super I/O Index and Data Ports
Programmable Timer
Keyboard Controller
NMI Status & Control Register
NMI Mask (bit 7) & RTC Address (bits 6:0)
Real Time Clock (RTC)
BIOS Timer
0070h
0071h
0080h–0081h
0080h–008Fh
0092h
DMA Low Page Register
System Control Port A (PC-AT† control Port)
Interrupt Controller 2
DMA Controller 2
00A0h–00BFh
00C0h–00DFh
00F0h
Clear NPX error
00F8h–00FFh
0170h–0177h
01F0h–01F7h
0200h–0207h
0220h–022Fh
0238h–023Fh
0278h–027Fh
02E8h–02EFh
02F8h–02FFh
0338h–033Fh
0370h–0375h
0378h–037Fh
03B4h–03BAh
03BCh–03BFh
x87 Numeric Coprocessor
Secondary Fixed Disk Controller (IDE)
Primary Fixed Disk Controller (IDE)
Game I/O Port
Serial Port A
Serial Port B
Parallel Port 3
Serial Port B
Serial Port B
Serial Port B
Secondary Floppy
Parallel Port 2
Monochrome Display Port
Parallel Port 1 (Primary)
Continued
M440LX Server System Product Guide
159
Download from Www.Somanuals.com. All Manuals Search And Download.
Address
Resource
03C0h–03CFh
03D4h–03DAh
03E8h–03EFh
03F0h–03F5h
03F6h–03F7h
03F8h–03FFh
0400h–043Fh
0461h
Video Display Controller
Color Graphics Controller
Serial Port A
Floppy Disk Controller
Primary IDE - Secondary Floppy
Serial Port A (Primary)
DMA Controller 1, Extended Mode Registers
Extended NMI / Reset Control
Software NMI
0462h
0480h–048Fh
04C0h–04CFh
04D0h–04D1h
04D4h–04D7h
04D8h–04DFh
04E0h–04FFh
0678h–067Ah
0778h–077Ah
07BCh–07BEh
0800h–08FFh
0CA4
DMA High Page Register
DMA Controller 2, High Base Register
Interrupt Controllers 1 and 2 Control Register
DMA Controller 2, Extended Mode Register
Reserved
DMA Channel Stop Registers
Parallel Port (ECP)
Parallel Port (ECP)
Parallel Port (ECP)
NVRAM
PCI to IRQ rerouter control (PCI_INTB_L, PCI_INTA_L)
PCI to IRQ rerouter control (PCI_INTD_L, PCI_INTC_L)
Reserved
0CA5
0CA6h–0CA7h
0CA9h
DISMIC Data Register
0CAAh
DISMIC Control/Status Register
DISMIC Flags Register
0CABh
0C84h
Board Revision Register
BIOS Function Control
0C85h–0C86h
0CF8h
PCI CONFIG_ADDRESS Register
PMC Turbo and Reset control
PCI CONFIG_DATA Register
Video Display Controller
SCSI registers
0CF9h
0CFCh
46E8h
xx00–xx1F*
*
SCSI I/O base address is set using the configuration registers.
160
Chapter 6 Server Resources
Download from Www.Somanuals.com. All Manuals Search And Download.
Interrupts
The following table shows the logical interrupt mapping of interrupt
sources on the system board.
Interrupt
Description (active-low signals have an “_L” symbol following them)
INTR
Processor interrupt.
NMI
NMI from DISMIC to processor.
IRQ0/MIRQ0
System board interrupt request 0 connected to input 2 of the I/O Apic. (For proper
operation, the BIOS must set the IRQ0 enable bit in PIIX3 register 70h during
initialization.)
IRQ1
RTC.
IRQ3
Serial port A or B interrupt from 87307VUL device, user configurable.
IRQ4
Serial port A or B interrupt from 87307VUL device, user configurable.
IRQ5
Parallel port.
Floppy diskette.
Parallel port.
IRQ6
IRQ7
IRQ8_L
IRQ9
IRQ10
IRQ11
IRQ12
IRQ14
IRQ15
IDE_IRQ
Keyboard/mouse interrupt from 87307VUL.
Compatibility IDE interrupt from primary IDE devices 0 and 1.
Tide to IRQ14; hard wired from PIIX3.
The following signals will be rerouted to the above interrupts:
PCI_INTA_L
PCI_INTB_L
PCI_INTC_L
PCI Interrupt signal A from PIIX3. Wired to PCI-0 slot 1 INTA_L, PCI-0 slot 2 INTD_L,
PCI-0 slot 3 INTC_L, PCI-0 slot 4 INTB_L, PCI-1 slot 1 INTA_L, and PCI-1 slot 2
INTD_L.
PCI Interrupt signal B from PIIX3. Wired to PCI-0 slot 1 INTB_L, PCI-0 slot 2 INTA_L,
PCI-0 slot 3 INTD_L, PCI-0 slot 4 INTC_L, PCI-1 slot 1 INTB_L, and PCI-1 slot 2
INTA_L. This interrupt is also used by the SCSI controller.
PCI Interrupt signal C from PIIX3. Wired to PCI-0 slot 1 INTC_L, PCI-0 slot 2 INTB_L,
PCI-0 slot 3 INTA_L, PCI-0 slot 4 INTD_L, PCI-1 slot 1 INTC_L, and PCI-1 slot 2
INTB_L. This interrupt is also used by the Network controller.
PCI_INTD_L
SMI_L
PCI Interrupt signal D from PIIX3. Wired to PCI-0 slot 1 INTD_L, PCI-0 slot 2 INTC_L,
PCI-0 slot 3 INTB_L, PCI-0 slot 4 INTA_L, PCI-1 slot 1 INTD_L, PCI-1 slot 2 INTC_L.
System Management Interrupt. General-purpose error indicator from a control PAL that
provides an SMI_L from nontraditional error sources (PERR_L, SERR_L, and others).
M440LX Server System Product Guide
161
Download from Www.Somanuals.com. All Manuals Search And Download.
Flash ROM
An 8-bit flash memory device provides 512 K x 8 of BIOS and nonvolatile
storage space. The device is addressed as 8-bit ISA memory.
You can load a new copy of the BIOS into flash memory by using the Flash
Memory Update Utility (FMUP) diskette.
■ ■ ■
■ ■ ■
162
Chapter 6 Server Resources
Download from Www.Somanuals.com. All Manuals Search And Download.
Power System 7
This chapter describes the power system and explains how to calculate
power consumption.
Power System Configurations
The server contains a modular power system that may be configured with
one, two, or three 360 watt power supplies.
Configuration level
Entry
Redundancy
Nonredundant
Redundant
Number of supplies
1
2
2
3
Entry
Maximum
Maximum
Nonredundant
Redundant
An entry level power system typically limits the server configuration to
dual processors, 1 GB memory, five hard drives, and total power dissipated.
A maximum level power system provides power for fully configured
servers.
Each power supply has a built-in fan and its own power cord. For servers
with redundant power systems, the loss of a single power supply will not
affect the operation of the server.
M440LX Server System Product Guide
163
Download from Www.Somanuals.com. All Manuals Search And Download.
A redundant power system uses a power share backplane to distribute
power to the server. The backplane implements these server management
features:
•
•
•
•
•
•
•
I2C bus
Power supply failure
Maximum current
Current usage
Number of power supplies installed in the server’s power system
Redundant mode
240 VA limit
The current sensing feature of the power share backplane shuts down the
entire power system if any single output from the backplane to the system
board or peripherals exceeds 240 VA. Current sensing limits the energy
supplied by the power share backplane to levels generally accepted as
operator accessible areas—less than 240 VA for the CSA Level 3 category—
without the use of interlocks.
If a power supply fails in a redundant power system, the yellow power
supply failure LED on the front panel starts flashing. The power supply can
be easily replaced without shutting down the system. The power supply is
inserted through the back of the chassis and held in place with four screws.
Power System Voltages
+3.3V
+5V +12V
-5V
-12V
One power supply, entry level nonredundant
(Total combined output power of +3.3 V and +5 V
should not exceed 178W)
13 A
32 A
15.5 0.25 A 0.5 A
A
Two power supplies, entry level redundant
13 A*
30 A
46 A
13.5 0.25 A 0.5 A
A
Two power supplies, maximum level
nonredundant
18 A
**
29 A 0.5 A 1.0 A
Three power supplies, maximum level redundant
18 A 46 A
**
29 A 0.5 A 1.0 A
*
No more than 5A to be used by PCI slots.
** No more than 10A to be used by PCI slots.
164
Chapter 7 Power System
Download from Www.Somanuals.com. All Manuals Search And Download.
Power System Control Signals
Power Enable/Disable (PON)
The PON control signal originates on the system board, and it is routed
through the power share backplane microcontroller. If the +5 V and +12 V
power going to the system board or the peripherals exceeds 240 VA, the
backplane microcontroller will disassert the PON control going to each
power supply (J4, J6, and J9). This signal is used to enable and disable the
power supplies.
Remote Sense Connections
Individual remote sense outputs are provided to each +5 V and +3.3 V
power supply section. Remote voltage sense for +5 V and +3.3 V is done on
the system board. The +5 V and +3.3 V remote sense lines are routed
through the power share backplane and connect to the current sense
circuitry.
The +12 V is not sensed remotely. Instead, it is sensed on the power share
backplane.
Load Share Connection
In systems with redundant power systems, the +5 V, +3.3 V, and +12 V
outputs from each power supply are routed through the power share
backplane. The current from each power supply output is monitored with a
current monitoring circuit. This current’s value is used to adjust the load
share of each power supply output.
Output Power Connections
The +12 V, +5 V, and +3.3 V power outputs are routed through J1 to the
system board power connector. The +12 V and +5 V power outputs are also
routed through J5 to the peripheral power connector.
The -12 V, -5 V, and +5 V standby outputs are joined together through an
isolation circuit and connected to the system board through connector J1.
M440LX Server System Product Guide
165
Download from Www.Somanuals.com. All Manuals Search And Download.
Power Good Circuit
The power good circuit looks at the levels of the power good (PGOOD)
signals. When the backplane PGOOD circuit senses a PGOOD signal, a
system PGOOD is asserted after an approximately 550 ms delay. Only a
single PGOOD signal assertion will cause the assertion of the system
PGOOD.
VA Monitor Circuit
The total supply current that forms part of the load sharing circuit monitors
+3.3 V as well as +5 V and +12 V on the system board. The microcontroller
determines the current supplied to the system board by subtracting the
peripheral current from the total current.
If either the system board power or peripheral power exceeds 240 VA, the
backplane microcontroller disables the supply outputs by disasserting PON.
The following table shows the maximum available current to each of the
system connections. Resetting the circuit requires unplugging all of the
power supplies.
Connectors
+5 V
+12 V
J1
J5
44 A (+4 A)
44 A (+4 A)
16 A (+4 A)
16 A (+4 A)
The maximum current number shown is the sum of the currents from all
supplies.
I²C Communication Circuit
The power share backplane microcontroller communicates with a similar
device on the system board through an I2C data link. This link reports the
number of power supplies in the server, current and power to the system
board and peripherals, and power supply status. The I2C signals are routed
through J2 to the system board.
166
Chapter 7 Power System
Download from Www.Somanuals.com. All Manuals Search And Download.
System Current Monitor
The system current monitor on the power share backplane sends a power
usage report to the server via the I2C communications bus. The backplane
microcontroller contains analog-to-digital converters that monitor DC
voltage levels supplied by the current sense circuits. They represent the
current load on the +3.3 V output from the system board and the +5 V and
+12 V load at both the system board and the peripheral bays.
If either the +5 V or +12 V load from the system board or the peripherals
goes beyond the CSA Level 3 requirement of 240 VA, the power is shut off
immediately by disserting PON. It is impossible to draw 240 VA from the
3.3 Volt power supply output even when three supplies are installed in the
server. The following table shows the maximum current allowed by each
voltage output for a server with three 360 watt power supplies.
Voltage Maximum Current in Amperes
240 VA Limit
N/A
+3.3 V
+5 V
33 A
96 A
48 A
+12 V
36 A (or 48 A for 12 ns maximum)
20 A
A voltage level within the range of 0 to 5 V is supplied by the current sense
circuits on the power share backplane. The current limit threshold is set to
44 A ±4 A for each +5 V channel and 16 A +4 A for each +12 V channel.
Power Supply FAULT
Each power supply provides a power good (PGOOD) signal that is asserted
high. If a power supply fails, its PGOOD signal goes low. The power
supply outputs are enabled through assertion of the PON signal. If the
PGOOD signal goes low, indicating a power bad condition while PON is
asserted, a FAULT is generated and applied to one of the FAULT inputs of
the backplane microcontroller.
Power Supply Presence DETECT
The DETECT signal senses the number of power supplies (operational or
not) in the server. Each power supply presents a grounding connection to
one of the backplane microcontroller input pins to show that a power
supply is present. If a power supply is not present, the backplane
microcontroller input pin will be pulled high through a pull-up resistor to
+5 V standby.
M440LX Server System Product Guide
167
Download from Www.Somanuals.com. All Manuals Search And Download.
Power Share Backplane Interconnections
Power Supply to Powershare Board Connections
The following power supply signals connect to input connectors J3, J7, and
J11 on the power share backplane.
PIN
1
SIGNAL
PIN
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
SIGNAL
Power Good
+5V Standby
Predictive Failure
+3.3V Remote Sense
Supply Present (Pwr Gnd)
-5VDC
PS-ON
2
Remote Sense Return
+5V Remote Sense
+12V Remote Sense
+24VDC
3
4
5
6
-12VDC
7
Ground
+5VDC
8
Ground
+5VDC
9
Ground
+5VDC
10
11
12
13
14
15
16
17
18
Ground
+5VDC
Ground
+5VDC
Ground
+5VDC
Ground
+12VDC
Ground
+12VDC
Ground
+12VDC
Ground
+3.3VDC
Ground
+3.3VDC
Ground
+3.3VDC
168
Chapter 7 Power System
Download from Www.Somanuals.com. All Manuals Search And Download.
Backplane to System Board Power Interface
Connector J1 on the backplane provides power to the system board.
Pin
1
Signal
+5 V
Color
Red
Pin
13
14
15
16
17
18
19
20
21
22
23
24
Signal
+5 V
Color
Red
2
+5 V
Red
+5 V
Red
3
-5 V
White
Blue
+5 V
Red
4
-12 V
GND
GND
GND
GND
GND
+3.3 V
+12 V
+12 V
+5 V
Red
5
Black
Black
Black
Black
Black
Orange
Yellow
Yellow
GND
GND
GND
GND
GND
+3.3 V
+3.3 V
+12 V
Black
Black
Black
Black
Black
Orange
Orange
Yellow
6
7
8
9
10
11
12
Backplane to Peripheral Interface
Connector J5 on the backplane supplies +5 VDC and +12 VDC power to the
server peripherals.
Pin
1
Signal
GND
Description
Pin
11
12
13
14
15
16
17
18
19
20
Signal
GND
Description
SCSI Bay #1, Ground
SCSI Bay #1, +5 V
SCSI Bay #1, Ground
SCSI Bay #1, +12 V
2
+5 VDC
GND
+12 VDC
GND
3
SCSI Bay #2, Ground
SCSI Bay #2, +5 V
SCSI Bay #2, Ground
SCSI Bay #2, +12 V
4
+5 VDC
GND
+12 VDC
GND
5
Peripheral Bay #1, Ground
Peripheral Bay #1, +5 V
Peripheral Bay #2, Ground
Peripheral Bay #2, +5 V
Peripheral Bay #3, Ground
Peripheral Bay #3, +5V
Peripheral Bay #1, Ground
Peripheral Bay #1, +12 V
Peripheral Bay #1, Ground
Peripheral Bay #1, +12 V
Peripheral Bay #1, Ground
Peripheral Bay #1, +12 V
6
+5 VDC
GND
+12 VDC
GND
7
8
+5 VDC
GND
+12 VDC
GND
9
10
+5 VDC
+12 VDC
M440LX Server System Product Guide
169
Download from Www.Somanuals.com. All Manuals Search And Download.
Backplane to System Board Control Connections
Connector J2 on the backplane connects I2C, remote sense, and power
supply controls to the system board.
Pin
1
Connector Designator
RS GND
+5 V RS
+3.3 V RS
GND
Description
Remote sense ground (-)
+5 VDC remote sense (+)
+3.3 VDC remote sense (+)
Ground
2
3
4
5
I2C-SCL
I2C-SDA
GND
I²C serial clock
I²C serial data
Ground
6
7
8
PGOOD
PON
Power good indication
Power ON control
Ground
9
10
11
12
13
14
GND
+5 V Stdby
NC
+5 VDC standby
Key
+24 V
+24 VDC
24 V RTN
24 VDC return
Power Supply Input Voltages
The server may contain one, two, or three autoranging 360 watt power
supplies that are designed to minimize EMI and RFI. The input voltage
ranges are
•
•
100-120 VAC at 50/ 60 Hertz (Hz); 6.0 A maximum current
200-240 VAC at 50/ 60 Hz; 3.0 A maximum current
170
Chapter 7 Power System
Download from Www.Somanuals.com. All Manuals Search And Download.
Power Supply Output Voltages
The table below lists the total watts available for each voltage. Adjust your
loads so that the combined total wattage for your system configuration is
less than
•
•
•
360 watts for an entry level nonredundant power system
318.5 watts for an entry level redundant power system
649 watts for a maximum level power system
For information about calculating the power usage for your system
configuration, see "Calculating Power Usage" on page 174
Maximum
Minimum
Continuous Load
Voltage
+3.3 V
+5.0 V
–5.0 V
Current
13.0 A
30.0 A
0.25 A
Current
Peak Current
Watts
39 W
0.5 A
5.0 A
150.0 W
1.25 W
5V Standby 0.1 A
+12.0 V
–12.0 V
15.5 A
0.5 A
2.0 A
16.0 A
186.0 W
6.0 W
M440LX Server System Product Guide
171
Download from Www.Somanuals.com. All Manuals Search And Download.
Server Current Usage
As an overall current usage limitation on the power supply, do not exceed
its maximum output capacity of 32 amperes at +5 volts (160 watts) and 11
amperes at +3.3 volts (36.3 watts). The combined power output for the +5
and +3.3 volt outputs should not exceed 178 watts.
The maximum current allowed at +5 volts for each PCI and ISA slot on the
system board is 2 amperes (10 watts).
The cooling efficiency varies per slot; therefore, ensure that adequate
cooling is available in the target slot—especially in an expansion slot
drawing more than 2.0 amperes.
172
Chapter 7 Power System
Download from Www.Somanuals.com. All Manuals Search And Download.
Current (maximum) at voltage levels:
Device
+5 V
1.8 A
+3.3 V
3.0 A
+12 V
5.5 A
–12 V
System board (includes first processor)
0.05 A
Note
✏
The current usage may vary
depending on the processors and the
size and number of DIMMs installed
on the memory module.
Second processor :
10 A
0 A
0 A
0
Note
✏
The current usage may vary
depending on the processors and the
size and number of DIMMs installed
on the memory module.
RPX board
3.0 A
0.5 A
0.3 A
0.8 A
0.3 A
0.4 A
2.0 A
2.0 A
Server monitor module
3.5-inch diskette drive
3.5-inch SCSI hard disk drive, 4 GB
SCSI tape drive
0.8 A
0.8 A
2.0 A
1.0 A
CD-ROM drive
ISA bus slot
PCI bus slot
2.0 A
Cooling blower 1, 97 mm
Cooling blower 2, 97 mm
Cooling fan 3, 92 mm
Cooling fan 4, 92 mm
Cooling fan 5, 92 mm
0.43 A
0.43 A
0.43 A
0.43 A
0.43 A
SCSI hot-docking backplane
1.0 A
M440LX Server System Product Guide
173
Download from Www.Somanuals.com. All Manuals Search And Download.
Calculating Power Usage
Use the worksheets in Tables 7-1 and 7-2 to calculate the total DC power
used by your system configuration.
The documentation that comes with each add-in board and peripheral
device should specify its current and voltage requirements.
To calculate the total combined wattage for your system, do this:
1. List the current for each board and device in the appropriate voltage
level column in Table 7-2.
2. Add the currents in each column of Table 7-2, and enter the total current
for each column in Table 7-1.
3. Multiply the voltage by the total current to get the total wattage for each
voltage level.
4. Add the total wattage for each voltage level to arrive at a total
combined power usage on the power supply.
Note
✏
The total combined wattage for your system configuration
must be less than 360 watts.
Table 7-1. Total Combined Power Used by Your System
Voltage Level and Total Current
(V X A = W)
Total Watts
for Each Voltage Level
(+3.3 V) X (______ A)
(+5 V) X (______ A)
(−5 V) X (______ A)
(+12 V) X (______ A)
(–12 V) X (______ A)
________ W
________ W
________ W
________ W
________ W
Total Combined Wattage
________ W
174
Chapter 7 Power System
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 7-2. Worksheet for Calculating DC Power Usage
Current (maximum) at voltage levels:
Device
System board
+3.3 V
3.0 A
+5 V
1.8 A
–5 V
+12 V
0.1 A
–12 V
0.1 A
Second processor
RPX board
0
0
10.0 A
3.0 A
0.3 A
0.4 A
0
0
0
0
3.5-inch diskette drive
CD-ROM drive
Cooling fan 1, 92 mm
Cooling fan 2, 92 mm
Cooling fan 3, 92 mm
Cooling fan 4, 92 mm
Cooling fan 5, 92 mm
PCI-P slot 1
1.0 A
0.43 A
0.43 A
0.43 A
0.43 A
0.43 A
PCI-P slot 2
PCI-P slot 3
PCI-S slot 1
PCI-S slot 2
PCI-S slot 3
PCI-S slot 4
ISA slot 1
ISA slot 2
ISA slot 3
Continued
M440LX Server System Product Guide
175
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 7-2. Worksheet for Calculating DC Power Usage
Current (maximum) at
voltage levels:
Device
+5 V
+12 V
1st 3.5-inch SCSI hard disk drive
2nd 3.5-inch SCSI hard disk drive
3rd 3.5-inch SCSI hard disk drive
4th 3.5-inch SCSI hard disk drive
5th 3.5-inch SCSI hard disk drive
6th 3.5-inch SCSI hard disk drive
7th 3.5-inch SCSI hard disk drive
8th 3.5-inch SCSI hard disk drive
9th 3.5-inch SCSI hard disk drive
10th 3.5-inch SCSI hard disk drive
SCSI tape drive
CD-ROM drive
IDE drive
Total Current
■ ■ ■
■ ■ ■
176
Chapter 7 Power System
Download from Www.Somanuals.com. All Manuals Search And Download.
System Board Jumpers 8
This chapter tells how to set the system board jumpers for specific operating
parameters.
Warnings and Cautions
Before you remove the covers to work inside it, observe the warnings and
cautions provided for your safety on page 3, “Safety Guidelines.” System
integration should be done by a qualified technical person.
Tools and Supplies You Need
•
•
•
•
Phillips (cross-head) screwdriver (#1 bit and #2 bit)
Jumper removal tool or needle-nosed pliers
Pen or pencil
Antistatic wrist strap (recommended)
M440LX Server System Product Guide
177
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuration Jumpers
The jumper is a small plastic-encased conductor (shorting plug) that slips
over two jumper pins. To change a jumper setting, use a jumper removal
tool, needle-nosed pliers, or your fingers to remove the jumper from its
current location. Position the jumper over the two pins for the desired
setting, and press it onto them. Be careful not to bend the pins.
The figure below shows the default jumper settings.
21J
ENABLE
PROT
CPU
SPEED
RECVR
NOR
BOOT
OPT
CLR
PASS-
WORD
PROT
CLR
CMOS
PROT
OM05777
Figure 8-1. System Board Jumpers
178
Chapter 8 System Board Jumpers
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 8-1. System Board Jumpers
Pins (default
Jumper
in bold)
Description
CPU Speed
Enable
Permits changing the processor speed in the BIOS setup
program.
Prevents changing the processor speed.
Protect
Boot Option
Recovery
Boot
Prevents inverting address A16. Allows the system to boot
from the Recovery BIOS when the normal BIOS gets
corrupted if you are unable to reload a fresh copy from
the diskette.
Inverts address A16 so the Normal BIOS does not reside
at the top of Flash memory where the write-protected
Recovery BIOS region is located.
Normal Boot
Password
CMOS
Clear
Clears the password.
Maintains the current system password.
Protect
Clear
Replaces the contents of NVRAM with the manufacturing
default settings.
Preserves the contents of NVRAM.
Protect
Chassis Intrusion Detection
The chassis contains alarm switches that get activated if a cover is removed.
To bypass the chassis intrusion switches, do this:
1. Observe the precautions on page 3, “Safety Guidelines.”
2. Remove the left side cover as described in Chapter 4, “Working Inside
Your System.”
3. Move the jumper on J3J1, Chassis INTR Detect from the ENA pins to
the DIS pins.
4. Replace the left side cover, and connect the power cord(s) to the system.
5. Turn the system on, and wait for POST to complete; for instructions on
running POST, see Chapter 3, “Configuring The System.”
6. Run the SCU to configure your system. For information on running the
SCU, see Chapter 3, "Configuring The System."
M440LX Server System Product Guide
179
Download from Www.Somanuals.com. All Manuals Search And Download.
Fault Resilient Booting (FRB)
The jumper on the J3J1 FRB ENA pins allows the system to boot from
processor 1 if processor 0 fails. Moving the jumper to the DIS pins lets the
system boot only from processor 0.
To boot only from processor 0, do this:
1. Observe the precautions on page 3, “Safety Guidelines.”
2. Remove the left side cover as described in Chapter 4, “Working Inside
Your System.”
3. Move the jumper on the J3J1, FRB from the ENA pins to the DIS pins.
4. Replace the left side cover, and connect the power cord(s) to the system.
5. Turn the system on, and wait for POST to complete; for instructions on
running POST, see Chapter 3, “Configuring The System.”
6. Run the SCU to configure your system. For information on running the
SCU, see Chapter 3, "Configuring The System."
Flash Memory
The jumper on the J3J1, Flash PROG pins applies +12 V power to the VPP
pin on the flash memory device. This allows you to update the BIOS in
flash memory with a special Flash Memory Update Utility. Moving the
jumper to the PROT pins protects the contents of flash memory.
For a copy of the latest system BIOS release, contact your dealer or sales
representative.
Updating the BIOS
Before you can update the system BIOS from the Flash Memory Update
Utility diskette, you must make it MS-DOS bootable. You must have either
MS-DOS version 5.00 or 6.00 (or greater) installed on C:\ DOS.
To prevent accidentally installing a BIOS for a different type of system, the
update utility insures that the BIOS matches the target system.
CAUTION
!
▲
▲
To avoid memory conflicts, do not run the update utility
with extended memory managers.
180
Chapter 8 System Board Jumpers
Download from Www.Somanuals.com. All Manuals Search And Download.
To update the BIOS, do this:
1. Observe the precautions on page 3, “Safety Guidelines.”
2. Insert the update diskette into drive A, and turn on the monitor and
system. The update process starts automatically when the system
boots. Follow the screen prompts.
3. When the update process completes, remove the diskette, and press
reset. Wait for POST to complete; for instructions on running POST, see
Chapter 3, “Configuring The System.”
4. If you want to protect the contents of flash memory, turn the system off
and remove the left side cover as described in Chapter 4, “Working
Inside Your System.”
5. Move the jumper on the J3J1, Flash PROG pins to the PROT pins to
write protect the flash memory device.
6. Replace the left side cover, and connect the power cord(s) to the system.
Note
✏
If the system BIOS becomes corrupted during the update
process—for example, a power outage occurs—follow the
“Recovering the BIOS” procedure on page 182.
CPU Speed
To set the processor speed, do this:
CAUTION
!
▲
▲
Over-clocking the processor may damage it and your data.
1. Observe the precautions on page 3, “Safety Guidelines.”
2. Remove the left side cover as described in Chapter 4, “Working Inside
Your System.”
3. Move the jumper on the J2J1, CPU Speed PROT pins to the Enable pins
to activate the CPU Speed Setting field in the BIOS Setup Utility.
4. Replace the left side cover, and connect the power cord(s) to the system.
5. Run the BIOS Setup Utility as described in Chapter 3, “Configuring The
System.”
6. Select the proper speed for your processor.
7. Repeat step 2 above.
8. Move the jumper on the J2J1, CPU Speed Enable pins to the PROT pins.
9. Repeat step 4 above.
M440LX Server System Product Guide
181
Download from Www.Somanuals.com. All Manuals Search And Download.
Boot Option
Moving the boot option jumper on the J2J1, Boot Opt NOR pins to the
REC pins enables the BIOS flash memory special recovery mode. The
system BIOS can be corrupted, for example, when the update procedure is
aborted due to a power outage. However, flash memory contains a
protected area that cannot be corrupted. Code in this area is used to boot
the computer from drive A when the BIOS has been corrupted. After
booting, the Flash Memory Update Utility is used to automatically recover
the system BIOS from the BIOS recovery files on the diskette.
Note
✏
If you have mapped the BIOS of an add-in board to any part
of the E0000H address range, you must either map it to
another area before completing a recovery procedure or
physically remove the board from the system. You do not
have to remove add-in boards for normal BIOS updates.
Recovering the BIOS
To recover the BIOS, do this:
1. Observe the precautions on page 3, “Safety Guidelines.”
2. Remove the left side cover as described in Chapter 4, “Working Inside
Your System.”
3. Move the jumper from the J2J1, Boot Opt NOR pins to the REC pins to
allow the system to boot from the recovery BIOS.
4. Replace the left side cover, and insert the Flash Memory Update Utility
diskette in drive A.
5. Connect the power cord(s) to the system, and turn it on. After the
system boots, the speaker emits a single beep and the recovery process
starts—it takes about three minutes. When the recovery process
completes, the speaker emits two beeps.
While in the recovery mode, there is no screen display on the
monitor. The keyboard is disabled as the system automatically
recovers the BIOS. The following beep codes describe the
recovery status.
182
Chapter 8 System Board Jumpers
Download from Www.Somanuals.com. All Manuals Search And Download.
Beep Code
Message
2
4
Successful completion, no errors.
The system could not boot from the diskette. The
diskette may not be bootable.
Continuous series
of low beeps
The wrong BIOS recovery files are being used
and/or the flash memory jumper is in the wrong
position.
6. Turn the system off, disconnect the power cord(s) from the system, and
remove the left side cover.
7. Move the jumper from the REC pins to the NOR pins to enable the
normal boot mode.
8. Replace the left side cover, remove the diskette from drive A, and
connect the power cord(s) to the system.
9. After running the special recovery mode, run the SCU to specify a new
password. For information on running the SCU, see Chapter 3,
“Configuring The System.”
Password
The jumper on the J2J1, Password PROT pins protects the system password
during system reset. Moving the jumper to the CLR pins clears the system
password during system reset.
To clear and enter your password, do this:
1. Observe the precautions on page 3, “Safety Guidelines.”
2. Remove the left side cover as described in Chapter 4, “Working Inside
Your System.”
3. Move the jumper on the J2J1, Password PROT pins to the CLR pins.
4. Replace the left side cover, and connect the power cord(s) to the system.
5. Turn the system on, and wait for POST to complete. This automatically
clears the password. For instructions on running POST, see Chapter 3,
“Configuring The System.”
6. Turn the system off; disconnect the power cord(s), and remove the left
side cover.
7. Move the jumper on the J2J1, Password CLR pins to the PROT pins.
8. Replace the left side cover, and connect the power cord(s) to the system.
9. Run the SCU to specify a new password. For information on running
the SCU, see Chapter 3, “Configuring The System.”
M440LX Server System Product Guide
183
Download from Www.Somanuals.com. All Manuals Search And Download.
CMOS
The jumper on the J2J1, CMOS PROT pins preserves the CMOS settings
during system reset. Moving the jumper to the CLR pins clears CMOS and
sets it and the real-time clock (RTC) to the manufacturing default settings
during system reset.
To reset the system’s CMOS and the RTC to factory default values, do this:
1. Observe the precautions on page 3, “Safety Guidelines.”
2. Remove the left side cover as described in Chapter 4, “Working Inside
Your System.”
3. Move the jumper on the J2J1, CMOS PROT pins to the CLR pins.
4. Replace the left side cover, and connect the power cord(s) to the system.
5. Turn the system on, and wait for POST to complete. This automatically
reprograms CMOS and RTC to their default settings. For instructions
on running POST, see Chapter 3, “Configuring The System.”
6. Turn the system off, disconnect the power cord(s) from the system, and
remove the left side cover.
7. Move the jumper on the J2J1, CMOS CLR pins to the PROT pins.
8. Replace the left side cover, and connect the power cord(s) to the system.
9. Run the SCU to configure your system. For information on running the
SCU, see Chapter 3, "Configuring The System."
■ ■ ■
■ ■ ■
184
Chapter 8 System Board Jumpers
Download from Www.Somanuals.com. All Manuals Search And Download.
9
I/O Ports and Connectors
Signal States
In all tables in this chapter, active-low signal names have an “_L” symbol
following the name; for example, P_REQ_SLOT0_L. Active-high signal
names do not have a “_L” suffix.
Server System Board
The system board contains both PCI and ISA I/ O systems with several
embedded devices for video, network, and disk control. The board also
provides
•
•
•
server management/ monitoring hardware support
interrupt control (I/ O APIC and standard PC)
a primary PCI bus segment (PCI-0) with four expansion connectors and
two embedded devices
•
•
an ISA bus segment with three expansion connectors (one physically
shared with PCI-0)
a National Semiconductor Super I/ O chip providing all PC-compatible
I/ O and Xbus interfaces
M440LX Server System Product Guide
185
Download from Www.Somanuals.com. All Manuals Search And Download.
System Board Layout
A
BCD E F GH I
J
K
DD
CC
L
BB
M
FF
N
EE
O
P
Q
R
S
AA
T
U
V
Z
Y
X
W
OM05772
Figure 9-1. System Board Layout
186
Chapter 9 I/O Ports and Connectors
Download from Www.Somanuals.com. All Manuals Search And Download.
System Board Connector Locations
A
B
C
D
E
F
G
H
I
Narrow SCSI connector
IDE connector
Q
R
Fan 3 connector
RP connector
I2C connector
S
I2C connector
Fan 0
T
Server management connector
Jumper block J2J1
Fan 4 connector
Floppy drive connector
Power connector
U
V
Hard disk activity input
Auxiliary power connector
Front panel connector
VRM connector
W
X
Wide SCSI channel B
Wide SCSI channel A
ISA bus slots
Y
J
Z
Secondary PCI bus slots
Primary PCI bus slots
Parallel and Video connectors
K
L
Speaker connector
Secondary processor connector
Primary processor connector
AA
BB
CC
M
Serial port 1 and Serial port 2
connectors
N
O
P
Blower 1 connector
DD
EE
FF
Keyboard and mouse connectors
Video memory upgrade socket
Back-up battery
Memory module connector
Blower 2 connector
M440LX Server System Product Guide
187
Download from Www.Somanuals.com. All Manuals Search And Download.
Power Connector
Pin
1
Signal
+5 V
Color
Red
Pin
13
14
15
16
17
18
19
20
21
22
23
24
Signal
+5 V
Color
Red
2
+5 V
Red
+5 V
Red
3
-5 V
White
Blue
+5 V
Red
4
-12 V
GND
GND
GND
GND
GND
+3.3 V
+12 V
+12 V
+5 V
Red
5
Black
Black
Black
Black
Black
Orange
Yellow
Yellow
GND
GND
GND
GND
GND
+3.3 V
+3.3 V
+12 V
Black
Black
Black
Black
Black
Orange
Orange
Yellow
6
7
8
9
10
11
12
Auxiliary Power Connector
Pin
1
Signal
+5 V Remote sense return
+5 V Remote sense
+3.3 V Remote sense
2
3
4
+3.3 V Remote sense return
I2C Connector
Pin
1
Signal
LOCAL_I2C_SCL
GND (ground)
LOCAL_I2C_SDA
2
3
188
Chapter 9 I/O Ports and Connectors
Download from Www.Somanuals.com. All Manuals Search And Download.
Control Panel Connector
Pin
1
Signal
Pin
9
Signal
GND
Fan failure
Chassis intrusion
Power fault condition
5 V standby
I2C-SDA
2
Hard disk activity
Reset system
Toggle system power
VCC
10
11
12
13
14
15
16
3
4
5
6
Spare
GND
I2C-SCL
7
NMI to CPU
VCC
8
GND
Diskette Drive Port
Pin
1
Signal
Pin
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
Signal
GND
FD_DIR_L
GND
2
FD_DENSEL
GND
3
FD_STEP_L
GND
4
n/c
5
Key
FD_WDATA_L
GND
6
FD_DRATE0
GND
7
FD_WGATE_L
GND
8
FD_INDEX_L
GND
9
FD_TRK0_L
FD_MSEN0
FD_WPROT_L
GND
10
11
12
13
14
15
16
17
FD_MTR0_L
GND
FD_DR1_L
GND
FD_RDATA_L
GND
FD_DR0_L
GND
FD_HDSEL_L
GND
FD_MTR1_L
FD_MSEN1
FD_DSKCHG_L
M440LX Server System Product Guide
189
Download from Www.Somanuals.com. All Manuals Search And Download.
Wide/Fast 16-Bit SCSI Connector
1
68
OM03878
Pin
1−16
17
Signal
Pin
49−50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
Signal
GND (ground)
TERMPWR
TERMPWR
RESERVED
GND (ground)
DB 12_L
DB 13_L
DB 14_L
DB 15_L
DB P1_L
DB 0_L
GND (ground)
TERMPWR
TERMPWR
RESERVED
GND (ground)
ATN_L
18
19
20−34
35
36
GND (ground)
BSY_L
37
38
ACK_L
39
RST_L
40
MSG_L
41
DB 1_L
SEL_L
42
DB 2_L
CD_L
43
DB 3_L
REQ_L
44
DB 4_L
I/O_L
45
DB 5_L
DB 8_L
46
DB 6_L
DB 9_L
47
DB 7_L
DB 10_L
DB 11_L
48
DB P_L
190
Chapter 9 I/O Ports and Connectors
Download from Www.Somanuals.com. All Manuals Search And Download.
IDE Connector
Pin
1
Signal
Pin
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
Signal
IDERST_L
GND
ID7
IDEDRQ
GND
2
3
DIOW_L
GND
4
ID8
5
ID6
DIOR_L
6
ID9
GND
7
ID5
IORDY
8
ID10
ID4
SPSYNC
IDEDAK_L
GND
9
10
11
12
13
14
15
16
17
18
19
20
ID11
ID3
IDEIRQ14
IDEIO16_L
IDESA1
ID12
ID2
ID13
ID1
PDIAG_L
IDESA0
ID14
ID0
IDESA2
IDECS0_L
IDECS1_L
IDEHDACT_L/DRVPRES_L
GND
ID15
GND
Keyed
M440LX Server System Product Guide
191
Download from Www.Somanuals.com. All Manuals Search And Download.
Fan Connectors
These connectors are identical.
Pin
1
Signal
GND (ground)
Fan sense
+12 V
2
3
Blower Connectors
These connectors are identical.
Pin
Signal
Boost
1
2
3
4
GND (ground)
Tachometer
+12 V
SCSI Controller Activity LED Connector
Pin
1
Signal
Return
2
Hard disk active
Hard disk active
Return
3
4
192
Chapter 9 I/O Ports and Connectors
Download from Www.Somanuals.com. All Manuals Search And Download.
Server Management Connector
Pin
1
Signal
Description
SMI_L (input)
I2CCLK (output
GND (power)
KEY
System management interrupt
I2C clock (8 MHz)
2
3
Electrical ground
4
No connection, pin missing
5
PWROFF_L (output)
I2CDATA (I/O)
LPOK (input)
KEYUNLK (input)
NMI (input)
Power supply off
I2C data signal
6
7
Host line power okay
Keyboard unlock (not used)
Nonmaskable interrupt
+3.3 V power
8
9
10
11
12
13
14
15
16
17
18
19
20
+3.3 V (input)
RESET_L (output)
GND (power)
GND (power)
KEY
Reset system board
Electrical ground
Electrical ground
No connection, pin missing
Host in secure mode
Electrical ground
SECURE (input)
GND (power)
INTRUD (input)
RESERVERED
KEY
Chassis is open
No connection, reserved for future use
No connection, pin missing
Electrical ground
GND (power)
M440LX Server System Product Guide
193
Download from Www.Somanuals.com. All Manuals Search And Download.
ISA Connectors
The system board ISA connectors follow the standard pinout given in the
ISA Specification.
Pin
A1
Signal
IOCHK_L
SD7
Pin
B1
Signal
GND
Pin
C1
Signal
SBHE_L
LA23
Pin
D1
Signal
MEMCS16_L
IOCS16_L
IRQ10
A2
B2
RSTDRV
+5 V dc
IRQ9
C2
D2
A3
SD6
B3
C3
LA22
D3
A4
SD5
B4
C4
LA21
D4
IRQ11
A5
SD4
B5
-5 V dc
DRQ2
C5
LA20
D5
IRQ12
A6
SD3
B6
C6
LA19
D6
IRQ15
A7
SD2
B7
-12 V dc
SRDY_L
+12 V dc
GND
C7
LA18
D7
IRQ14
A8
SD1
B8
C8
LA17
D8
DACK0_L
DRQ0
A9
SD0
B9
C9
MEMR_L
MEMW_L
SD8
D9
A10
A11
A12
A13
A14
A15
A16
A17
A18
A19
A20
A21
A22
A23
A24
A25
A26
A27
A28
A29
A30
A31
IOCHRDY
AEN
B10
B11
B12
B13
B14
B15
B16
B17
B18
B19
B20
B21
B22
B23
B24
B25
B26
B27
B28
B29
B30
B31
C10
C11
C12
C13
C14
C15
C16
C17
C18
D10
D11
D12
D13
D14
D15
D16
D17
D18
DACK5_L
DRQ5
SMEMW_L
SMEMR_L
IOW_L
IOR_L
SA19
SA18
SA17
SA16
SA15
SA14
SA13
SA12
SA11
SA10
SA9
SD9
DACK6_L
DRQ6
SD10
SD11
SD12
SD13
SD14
SD15
DACK7_L
DRQ7
DACK3_L
DRQ3
+5 V dc
Master16_L
GND
DACK1_L
DRQ1
REFRESH_L
SYSCLK
IRQ7
IRQ6
SA8
IRQ5
SA7
IRQ4
SA6
IRQ3
SA5
DACK2_L
TC
SA4
SA3
BALE
SA2
+5 V dc
+OSC
SA1
SA0
GND
194
Chapter 9 I/O Ports and Connectors
Download from Www.Somanuals.com. All Manuals Search And Download.
PCI Connectors
Pin
A1
A2
A3
A4
A5
A6
A7
A8
A9
Signal
TRST_L
+12 V
TMS
Pin
B1
B2
B3
B4
B5
B6
B7
B8
B9
Signal
−12 V
TCK
Pin
Signal
Pin
Signal
A32 AD16
A33 +3.3 V
A34 FRAME_L
A35 GND
A36 TRDY_L
A37 GND
A38 STOP_L
A39 +3.3 V
A40 SDONE
A41 SBO_L
A42 GND
A43 PAR
B32 AD17
B33 C-BE2_L
B34 GND
B35 IRDY_L
B36 +3.3 V
B37 DEVSEL_L
B38 GND
B39 LOCK_L
B40 PERR_L
B41 +3.3 V
B42 SERR_L
B43 +3.3 V
B44 C-BE1_L
B45 AD14
B46 GND
B47 AD12
B48 AD10
B49 GND
B50 KEY
GND
TDI
TD0
+5 V
+5 V
INTA_L
INTC_L
+5 V
+5 V
INTB_L
INTD_L
PRSNT1_L
Reserved
A10 +5 V
B10 Reserved
B11 PRSNT2_L
B12 GND
A11 Reserved
A12 GND
A13 GND
A14 Reserved
A15 RST_L
A16 +5 V
B13 GND
A44 AD15
A45 +3.3 V
A46 AD13
A47 AD11
A48 GND
A49 AD9
B14 Reserved
B15 GND
B16 CLK
A17 GNT
B17 GND
A18 GND
A19 Reserved
A20 AD30
A21 +3.3 V
A22 AD28
A23 AD26
A24 GND
A25 AD24
A26 IDSEL
A27 +3.3 V
A28 AD22
A29 AD20
A30 GND
A31 AD18
B18 REQ_L
B19 +5 V
A50 KEY
B20 AD31
B21 AD29
B22 GND
A51 KEY
B51 KEY
A52 C-BE0_L
A53 +3.3 V
A54 AD6
B52 AD8
B53 AD7
B23 AD27
B24 AD25
B25 +3.3 V
B26 C-BE3_L
B27 AD23
B28 GND
B54 +3.3 V
B55 AD5
A55 AD4
A56 GND
A57 AD2
B56 AD3
B57 GND
B58 AD1
A58 AD0
A59 +5 V
B59 +5 V
B29 AD21
B30 AD19
B31 +3.3 V
A60 REQ64_L
A61 +5 V
B60 ACK64_L
B61 +5 V
A62 +5 V
B62 +5 V
M440LX Server System Product Guide
195
Download from Www.Somanuals.com. All Manuals Search And Download.
Keyboard and Mouse Connectors
These identical PS/ 2 compatible connectors share a common housing. The
top one is the mouse, and the bottom one is the keyboard.
6
5
4
3
2
1
OM00951A
Mouse
Keyboard
Pin
1
Signal
Pin
1
Signal
MSEDAT (mouse data)
NC (not connected)
GND (ground)
KEYDAT (keyboard data)
NC (not connected)
GND (ground)
2
2
3
3
4
FUSED_VCC (+5 V)
MSECLK (mouse clock)
NC (not connected)
4
FUSED_VCC (+5 V)
KEYCLK (keyboard clock)
NC (not connected)
5
5
6
6
196
Chapter 9 I/O Ports and Connectors
Download from Www.Somanuals.com. All Manuals Search And Download.
Parallel Port
The IEEE 1284-compatible parallel port—used primarily for a printer—
sends data in parallel format.
13
1
25
14
OM00933A
Pin
1
Signal
Pin
10
Signal
Strobe
ACK_L (acknowledge)
Busy
2
Data bit 0
Data bit 1
Data bit 2
Data bit 3
Data bit 4
Data bit 5
Data bit 6
Data bit 7
11
3
12
PE (paper end)
SLCT (select)
4
13
5
14
AUFDXT_L (auto feed)
Error_L
6
15
7
16
INIT_L (initialize printer)
SLCTIN_L (select input)
GND (ground)
8
17
9
18−25
M440LX Server System Product Guide
197
Download from Www.Somanuals.com. All Manuals Search And Download.
VGA Video Port
5
1
10
6
15
11
OM00936A
Pin
Signal
1
Red (analog color signal R)
2
Green (analog color signal R)
Blue (analog color signal R)
NC (not connected)
3
4
GND (video ground)
5−8
9
NC (not connected)
10
11−12
13
14
15
GND (video ground)
NC (not connected)
HSYNC (horizontal sync)
VSYNC (vertical sync)
NC (not connected)
198
Chapter 9 I/O Ports and Connectors
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial Ports
These ports support external devices such as modems and scanners that
require serial data transmission.
1
5
6
9
OM00932A
Pin
1
Signal
DCD (data carrier detect)
RXD (receive data)
TXD (transmit data)
DTR (data terminal ready)
GND (ground)
2
3
4
5
6
DSR (data set ready)
RTS (request to send)
CTS (clear to send)
RIA (ring indicator)
7
8
9
■ ■ ■
■ ■ ■
M440LX Server System Product Guide
199
Download from Www.Somanuals.com. All Manuals Search And Download.
200
Chapter 9 I/O Ports and Connectors
Download from Www.Somanuals.com. All Manuals Search And Download.
Solving Problems10
This chapter helps you identify and solve problems that might occur while
using the server.
Resetting the Server
You can reset the server in a variety of ways.
Manually
Press
To
<Ctrl+Alt+Del>
Clear system memory and reload the operating system.
This is a "soft boot" reset.
Reset button
Power off/on
Clear system memory, restart POST, and reload the
operating system.
Turn the system power off and then on. This is a "cold
boot" reset; it has the same effect as pushing the reset
button except that power is halted to all peripherals.
Programmed
You can reset the server with software.
M440LX Server System Product Guide
201
Download from Www.Somanuals.com. All Manuals Search And Download.
Initial System Startup
Problems that occur at initial system startup are usually caused by incorrect
installation or configuration. Hardware failure is a less frequent cause.
Checklist
❑ Are all cables correctly connected and secured?
❑ Are the processor modules fully seated in their slots on the system
board?
❑ Are all add-in ISA and PCI boards fully seated in their slots on the
system board?
❑ Are all jumper settings on the system board correct? For information,
see Chapter 8, "System Board Jumpers."
❑ Are all jumper and switch settings on add-in boards and peripheral
devices correct? To check these settings, refer to the manufacturer’s
documentation that comes with them. If applicable, ensure that there
are no conflicts—for example, two add-in boards sharing the same
interrupt.
❑ Are all DIMMs on the memory module installed correctly? Refer to
Chapter 6, "Server Resources," for installation instructions.
❑ Are all add-in boards and peripheral devices installed correctly? Refer
to Chapter 4, "Working Inside Your System."
❑ If the system has a hard disk drive, is it properly formatted or defined?
❑ Is the SCSI hot-docking backplane configured and terminated correctly?
For information about the board, see Chapter 5, “SCSI Backplane and
Drives: Hot-swapping and Configuring .”
❑ Are all device drivers properly installed? For information about
installing drivers, see Chapter 3, "Configuring The System."
❑ Are the configuration settings made with the SCU correct? For
information about running the SCU, see Chapter 3, "Configuring The
System."
❑ Is the operating system properly loaded? Refer to the operating system
documentation.
❑ Did you press the power button on the front panel to turn the server on
(power-on light should be lit)?
202
Chapter 10 Solving Problems
Download from Www.Somanuals.com. All Manuals Search And Download.
❑ Is the system power cord properly connected to the system and plugged
into a NEMA 5-15R outlet for 100-120 VAC or a NEMA 6-15R outlet for
200-240 VAC? See "Connecting the Power Cord" in Chapter 2,
"Installing The System."
❑ Is AC power available at the wall outlet?
If these items are correct, but the problem recurs, refer to "Additional
Troubleshooting Procedures" on page 205.
Running New Application Software
Problems that occur when you run new application software are usually
related to the software. Faulty equipment is much less likely, especially if
other software runs correctly.
Checklist
❑ Does the system meet the minimum hardware requirements for the
software? Refer to the software documentation.
❑ Is the software an authorized copy? If not, get one; unauthorized copies
often do not work.
❑ If you are running the software from a diskette, is it a good copy?
❑ If you are running the software from a CD-ROM disc, is the disc
scratched or dirty?
❑ If you are running the software from a hard disk drive, is the software
correctly installed? Were all necessary procedures followed and files
installed?
❑ Are the correct device drivers installed?
❑ Is the software correctly configured for the system?
❑ Are you using the software correctly?
If the problems persist, contact the software vendor's customer service
representative.
M440LX Server System Product Guide
203
Download from Www.Somanuals.com. All Manuals Search And Download.
After the System Has Been Running Correctly
Problems that occur after the system hardware and software have been
running correctly often indicate equipment failure. Many situations that are
easy to correct, however, can also cause such problems.
Checklist
❑ If you are running the software from a diskette, try a new copy of the
software.
❑ If you are running the software from a CD-ROM disc, try a different
disc to see if the problem occurs on all discs.
❑ If you are running the software from a hard disk drive, try running it
from a diskette. If the software runs correctly, there may be a problem
with the copy on the hard disk drive. Reinstall the software on the hard
disk drive, and try running it again. Make sure all the necessary files
are installed.
❑ If a software application does not run correctly with the "Boot Speed"
set to turbo, try setting it to deturbo with Setup.
❑ If the problems are intermittent, there may be a loose cable, dirt in the
keyboard (if keyboard input is incorrect), a marginal power supply, or
other random component failures.
❑ If you suspect that a transient voltage spike, power outage, or brownout
might have occurred, reload the software and try running it again.
(Symptoms of voltage spikes include a flickering video display,
unexpected system reboots, and the system not responding to user
commands.)
Note
✏
If you are getting random errors in your data files, they may
be getting corrupted by voltage spikes on your power line.
If you are experiencing any of the above symptoms that
might indicate voltage spikes on the power line, you may
want to install a surge suppresser between the power outlet
and the server power cord.
❑ If the problem recurs after you have checked and corrected all the above
items, refer to "Additional Troubleshooting Procedures" on page 205.
❑ If you receive any error messages, refer to "Error and Informational
Messages" on page 213 for an explanation of the messages and
suggested corrective actions.
204
Chapter 10 Solving Problems
Download from Www.Somanuals.com. All Manuals Search And Download.
Additional Troubleshooting Procedures
This section provides a more detailed approach to identifying a problem
and locating its source.
Preparing the System for Diagnostic Testing
CAUTION
!
▲
▲
Before disconnecting any peripheral cables from the system,
turn off the system and any external peripheral devices.
Failure to do so can cause permanent damage to the system
and/ or the peripheral devices.
1. Turn off the system and all external peripheral devices. Disconnect all
of them from the system, except the keyboard and video monitor.
2. Make sure the system power cord is plugged into a properly grounded
AC outlet. Refer to Chapter 2, "Installing The System."
3. Make sure your video display monitor and keyboard are correctly
connected to the system. Turn on the video monitor. Set its brightness
and contrast controls to at least two-thirds of their maximum ranges
(refer to the documentation supplied with your video display monitor).
4. If the operating system normally loads from the hard disk drive, make
sure there is no diskette in drive A. Otherwise, place a diskette
containing the operating system files in drive A.
5. Turn on the system. If the power LED does not light, refer to "Power
Light Does Not Light" on page 207.
M440LX Server System Product Guide
205
Download from Www.Somanuals.com. All Manuals Search And Download.
Monitoring POST
See Chapter 3, "Configuring The System."
Verifying Proper Operation of Key System Lights
As POST determines the system configuration, it tests for the presence of
each mass storage device installed in the system. As each device is checked,
its activity light should turn on briefly. Check for the following:
❑ Does the diskette drive activity light turn on briefly? If not, refer to
"Diskette Drive Activity Light Does Not Light" on page 210.
❑ If a second diskette drive is installed, does its activity light turn on
briefly? If not, refer to "Diskette Drive Activity Light Does Not Light"
on page 210.
❑ If there is a hard disk drive or a SCSI device installed in the system,
does the drive activity light on the front panel turn on briefly? If not,
refer to "Hard Disk Drive Activity Light Does Not Light" on page 211.
Note
✏
See “Controls and Indicators” in Chapter 2, "Installing The
System."
Confirming Loading of the Operating System
Once the system boots up, the operating system prompt appears on the
screen. The prompt varies according to the operating system. If the
operating system prompt does not appear, refer to "Initial System Startup"
on page 202.
206
Chapter 10 Solving Problems
Download from Www.Somanuals.com. All Manuals Search And Download.
Specific Problems and Corrective Actions
This section provides possible solutions for the following specific problems:
•
•
•
•
•
•
•
•
•
•
Power light does not light.
System cooling fans do not rotate or rotate slowly.
No characters appear on screen.
Characters on the screen appear distorted or incorrect.
No beep or incorrect beep pattern.
Diskette drive activity light does not light.
Hard disk drive activity light does not light.
Tape drive activity light does not light.
The SCU does not boot.
Problems with application software.
Try the solutions in the order given. If you cannot correct the problem,
contact your service representative or authorized dealer for assistance.
Power Light Does Not Light
Check the following:
❑ Is the system operating normally? If so, the power LED is probably
defective or the cable from the front panel to the system board is loose.
❑ Are there other problems with the system? If so, check the items listed
under "System Cooling Fans Do Not Rotate Properly."
❑ Is the yellow power supply failure LED flashing? If so, a power supply
has failed.
If all items are correct and problems persist, contact your service
representative or authorized dealer for assistance.
M440LX Server System Product Guide
207
Download from Www.Somanuals.com. All Manuals Search And Download.
System Cooling Fans Do Not Rotate Properly
If the system cooling fans are not operating properly, system components
will be damaged.
Note
✏
The system has up to seven cooling fans three of them are
integral parts of the power supplies. There are no
serviceable components in the power supply. If the power
supply is opened, the warranty is voided.
Check the following:
Is AC power available at the wall outlets?
❑
❑
Are the system power cords properly connected to the system and the
wall outlets?
If present, are the fuses in the system AC power cord plugs okay?
Did you press the power button?
❑
❑
❑
❑
Is the power-on light lit?
Have any of the fan motors stopped (use the server management
subsystem to check the fan status)?
Are the fan power connectors properly connected to the system board?
Is the cable from the front panel board connected to the system board?
❑
❑
❑
Are the power supply cables properly connected to the power share
backplane?
Are the power share backplane cables properly connected to the system
board?
❑
❑
Are there any shorted wires caused by pinched cables or power
connector plugs forced into power connector sockets the wrong way?
If the switches and connections are correct and AC power is available at the
wall outlets, contact your service representative or authorized dealer for
assistance.
208
Chapter 10 Solving Problems
Download from Www.Somanuals.com. All Manuals Search And Download.
No Characters Appear on Screen
Check the following:
❑ Is the keyboard working?
❑ Is the video monitor plugged in and turned on?
❑ Are the brightness and contrast controls on the video monitor properly
adjusted?
❑ Are the video monitor switch settings correct?
❑ Is the video monitor signal cable properly installed?
❑ Is the onboard video controller enabled?
If you are using an add-in video controller board, do the following:
1. Verify that the video controller board is fully seated in the system board
connector.
2. Run the SCU to disable the onboard video controller and specify that an
offboard VGA/ EGA adapter is installed.
3. Reboot the system for changes to take effect.
4. If there are still no characters on the screen after you reboot the system
and POST emits a beep code, write down the beep code you hear. This
information is useful for your service representative. See “POST Beep
Codes” on page 213.
5. If you do not receive a beep code and characters do not appear, the
video display monitor or video controller may have failed. Contact
your service representative or authorized dealer for assistance.
Characters Are Distorted or Incorrect
Check the following:
❑ Are the brightness and contrast controls properly adjusted on the video
monitor? Refer to the manufacturer’s documentation.
❑ Are the video monitor signal and power cables properly installed?
If the problem persists, the video monitor may be faulty or it may be the
incorrect type. Contact your service representative or authorized dealer for
assistance.
M440LX Server System Product Guide
209
Download from Www.Somanuals.com. All Manuals Search And Download.
Incorrect or no Beep Codes
If the system operates normally, but there was no beep, the speaker may be
defective. Verify that the speaker is enabled by running the SCU. For
information about running the SCU, see Chapter 3, "Configuring The
System." If the speaker is enabled, but not functioning, contact your service
representative or authorized dealer for assistance.
Record the beep code emitted by POST, and refer to "Error and
Informational Messages" on page 213 for information about beep codes and
error messages.
Diskette Drive Activity Light Does Not Light
Check the following:
❑ Are the diskette drive power and signal cables properly installed?
❑ Are all relevant switches and jumpers on the diskette drive set
correctly?
❑ Is the diskette drive properly configured?
❑ Is the diskette drive activity light always on? If so, the signal cable may
be plugged in incorrectly.
If you are using the onboard diskette controller, use the SCU to make sure
that "Onboard Floppy" is set to "Enabled." If you are using an add-in
diskette controller, make sure that "Onboard Floppy" is set to "Disabled."
For information about running the SCU, see Chapter 3, "Configuring The
System."
If the problem persists, there may be a problem with the diskette drive,
system board, or drive signal cable. Contact your service representative or
authorized dealer for assistance.
210
Chapter 10 Solving Problems
Download from Www.Somanuals.com. All Manuals Search And Download.
Hard Disk Drive Activity Light Does Not Light
If you have installed one or more hard disk drives in your system, check the
following:
❑ Are the power and signal cables to the hard disk drive properly
installed?
❑ If your system contains a SCSI host adapter controller board, is it fully
seated in the system board connector?
❑ Are all relevant switches and jumpers on the hard disk drive and
controller board set correctly?
❑ Is the onboard IDE controller enabled?
Note
✏
The hard disk drive activity light on the front panel lights
when either an IDE hard disk drive or SCSI device is in use.
❑ Is the hard disk drive properly configured?
❑ If your system contains a SCSI host adapter controller board, is the hard
disk activity LED cable connector plugged into the controller board and
the system board?
If you received error messages, refer to "Error and Informational Messages"
on page 213 for information about error messages.
If you did not receive error messages, run the SCU and make sure that the
hard disk drive is configured with the correct parameters. For information
about running the SCU, see Chapter 3, "Configuring The System."
If the problem persists, there may be a problem with the hard disk drive, the
add-in controller board, system board, drive signal cable, or LED connector.
Contact your service representative or authorized dealer for assistance.
M440LX Server System Product Guide
211
Download from Www.Somanuals.com. All Manuals Search And Download.
Problems With Application Software
If you have problems with application software, do the following:
1. Verify that the software is properly configured for the system. Refer to
the software installation and operation documentation for instructions
on setting up and using the software.
2. Try a different copy of the software to see if the problem is with the
copy you are using.
3. Make sure all cables are installed correctly.
4. Verify that the system board jumpers are set correctly.
5. Try running the software in a different speed mode. Refer to Chapter 3,
"Configuring The System."
6. If other software runs correctly on the system, contact your vendor
about the failing software.
If the problem persists, contact the software vendor's customer service
representative for assistance.
212
Chapter 10 Solving Problems
Download from Www.Somanuals.com. All Manuals Search And Download.
Error and Informational Messages
When you turn on the system, POST displays messages that provide
information about the system. If a failure occurs, POST emits beep codes
that indicate errors in hardware, software, or firmware. If POST can display
a message on the video display screen, it causes the speaker to beep twice as
the message appears.
POST Beep Codes
Beep codes are a series of individual beeps, each one equal in length. Write
down the beep code you hear; this information is useful for your service
representative.
Table 10-1. POST Beep Codes
Beeps
Error Message and Conditions
1-2
ROM checksum error; ROM checksum value does not match encoded
value in BIOS
1-2-2-3
ROM checksum error; ROM checksum value does not match encoded
value in BIOS
1-3-1-1
1-3-1-3
Refresh failure; memory refresh circuitry on the baseboard is faulty
Keyboard controller gate A20 is off; BIOS cannot switch to protected
mode
1-3-4-1
1-4-1-1
2-1-2-3
2-2-3-1
Memory error
Memory error
ROM copyright notice failure
Unexpected interrupt
M440LX Server System Product Guide
213
Download from Www.Somanuals.com. All Manuals Search And Download.
POST Codes and Countdown Codes
The BIOS indicates the current testing phase during POST after the video
adapter has been successfully initialized by outputting a 2-digit hex code to
I/ O location 80h. If a port-80h ISA card is installed, it displays this 2-digit
code on a pair of hex display LEDs.
Normal Port-80 Codes
These are the port-80 codes and countdown codes displayed during the
normal BIOS POST process.
Table 10-2. Port-80 Codes
Port 80 Code
Reason
02
Verify Real Mode
04
06
08
09
0A
0B
0C
0E
0F
10
11
12
14
16
Get CPU type
Initialize system hardware
Initialize chipset registers with initial POST values
Set in POST flag
Initialize CPU registers
Enable CPU cache
Initialize caches to initial POST values
Initialize I/O
Initialize the local bus IDE
Initialize Power Management
Load alternate registers with initial POST values new
Restore CPU control word during warm boot
Initialize keyboard controller
BIOS ROM checksum
Continued
214
Chapter 10 Solving Problems
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 10-2. Port-80 Codes (continued)
Port 80 Code
Reason
18
8254 timer initialization
1A
1C
20
22
24
28
2A
2C
2E
30
32
34
35
36
37
38
39
3A
3C
3D
8237 DMA controller initialization
Reset Programmable Interrupt Controller
Test DRAM refresh
Test 8742 Keyboard Controller
Set ES segment register to 4GB
Autosize DRAM
Clear 512K base RAM
RAM failure on address line xxxx*
RAM failure on data bits xxxx* of low byte of memory bus
RAM failure on data bits xxxx* of high byte of memory bus
Test CPU bus-clock frequency
Test CMOS
RAMInitialize alternate chipset registers.
Warm start shut down
Reinitialize the chipset (MB only)
Shadow system BIOS ROM
Reinitialize the cache (MB only)
Autosize cache
Configure advanced chipset registers
Load alternate registers with CMOS valuesnew
Continued
M440LX Server System Product Guide
215
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 10-2. Port-80 Codes (continued)
Port 80 Code
Reason
40
Set Initial CPU speed new
42
44
46
47
48
49
4A
4B
4C
4E
50
51
52
54
56
58
5A
5C
60
62
64
66
Initialize interrupt vectors
Initialize BIOS interrupts
Check ROM copyright notice
Initialize manager for PCI Option ROMs
Check video configuration against CMOS
Initialize PCI bus and devices
Initialize all video adapters in system
Display QuietBoot screen
Shadow video BIOS ROM
Display copyright notice
Display CPU type and speed
Initialize EISA board
Test keyboard
Set key click if enabled
Enable keyboard
Test for unexpected interrupts
Display prompt "Press F2 to enter SETUP"
Test RAM between 512 and 640k
Test extended memory
Test extended memory address lines
Jump to UserPatch1
Configure advanced cache registers
Continued
216
Chapter 10 Solving Problems
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 10-2. Port-80 Codes (continued)
Port 80 Code
Reason
68
Enable external and CPU caches
6A
6C
6E
70
72
74
76
7A
7C
7E
80
82
85
86
88
8A
8C
90
91
92
93
94
Display external cache size
Display shadow message
Display non-disposable segments
Display error messages
Check for configuration errors
Test real-time clock
Check for keyboard errors
Test for key lock on
Set up hardware interrupt vectors
Test coprocessor if present
Detect and install external RS232 ports
Detect and install external parallel ports
Initialize PC-compatible PnP ISA devices
Re-initialize on board I/O ports.
Initialize BIOS Data Area
Initialize Extended BIOS Data Area
Initialize floppy controller
Initialize hard-disk controller
Initialize local-bus hard-disk controller
Jump to UserPatch2
Build MPTABLE for multi-processor boards
Disable A20 address line
Continued
M440LX Server System Product Guide
217
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 10-2. Port-80 Codes (continued)
Port 80 Code
Reason
95
Install CD ROM for boot
96
98
Clear huge ES segment register
Search for option ROMs. One long, two short beeps on
checksum failure
9A
9C
9E
A0
A2
A4
A8
AA
AC
AE
B0
B2
B4
B5
B6
B8
BC
BE
BF
Shadow option ROMs
Set up Power Management
Enable hardware interrupts
Set time of day
Check key lock
Initialize typematic rate
Erase F2 prompt
Scan for F2 key stroke
Enter SETUP
Clear in-POST flag
Check for errors
POST done – prepare to boot operating system
One short beep before boot
Display MultiBoot menu
Check password (optional)
Clear global descriptor table
Clear parity checkers
Clear screen (optional)
Check virus and backup reminders
Continued
218
Chapter 10 Solving Problems
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 10-2. Port-80 Codes (continued)
Port 80 Code
Reason
C0
Try to boot with INT 19
DO
D2
D4
D6
D8
DA
DC
Interrupt handler error
Unknown interrupt error
Pending interrupt error
Initialize option ROM error
Shutdown error
Extended Block Move
Shutdown 10 error
POST Error Codes and Messages
The following table defines POST error codes and associated messages.
These codes may change in the future as the Phoenix BIOS matures and
includes the support for POST error code display.
Table 10-3. POST Error Codes and Messages
Code
0002
0010
0015
0016
0042
0050
0051
0052
0053
Error message
Primary Boot Device Not Found
Cache Memory Failure, Do Not Enable Cache
Primary Output Device Not Found
Primary Input Device Not Found
ISA Config contains invalid info
PnP Memory Conflict:
PnP 32-bit Memory Conflict:
PnP IRQ Conflict:
PnP DMA Conflict:
Continued
M440LX Server System Product Guide
219
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 10-3. POST Error Codes and Messages (continued)
Code
0054
0055
0056
0060
0070
0080
0083
0085
0131
0132
0135
0140
0170
0171
0172
0173
0174
0175
0176
0177
0180
0181
0191
Error message
PnP Error Log is Full
Bad PnP Serial ID Checksum:
Bad PnP Resource Data Checksum:
Keyboard Is Locked ... Please Unlock It
CMOS Time & Date Not Set
Option ROM has bad checksum
Shadow of PCI ROM Failed
Shadow of ISA ROM Failed
Floppy Drive A:
Floppy Drive B:
Floppy Disk Controller Failure
Shadow of System BIOS Failed
Disabled CPU slot #
CPU Failure – Slot 1, CPU # 1
CPU Failure – Slot 1, CPU # 2
CPU Failure – Slot 2, CPU # 1
CPU Failure – Slot 2, CPU # 2
CPU modules are incompatible or one is not present.
Previous CPU Failure – CPU # 1
Previous CPU Failure – CPU # 2
Attempting to boot with failed CPU
BSP switched, system may be in uniprocessor mode
CMOS Battery Failed
Continued
220
Chapter 10 Solving Problems
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 10-3. POST Error Codes and Messages (continued)
Code
0195
0198
0289
0295
0297
0299
Code
0301
0302
0303
0310
0313
0370
0373
0375
0380
0392
0430
0440
0441
0445
0446
0450
Error message
CMOS System Options Not Set
CMOS Checksum Invalid
System Memory Size Mismatch
Address Line Short Detected
Memory Size Decreased
ECC Error Correction failure
Error message
ECC Single-bit correction failed, Correction Disabled
ECC Double-bit Error
ECC DIMMs incompatible
ECC Address failure, Partition #
ECC Memory Size Decreased, Bank #
Keyboard Controller Error
Keyboard Stuck Key Detected
Keyboard and Mouse Swapped
ECC DIMM failure, Board in slot 1 DIMM #
ECC DIMM failure, Board in slot 2 DIMM #
Timer Channel 2 Failure
Gate-A20 Failure
Unexpected Interrupt in Protected Mode
Master Interrupt Controller Error
Slave Interrupt Controller Error
Master DMA Controller Error
Continued
M440LX Server System Product Guide
221
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 10-3. POST Error Codes and Messages (continued)
Code
0451
0452
0460
0461
0465
0467
0501
0510
0511
0710
0711
0780
0781
0782
0783
0784
0785
0800
0801
0802
0803
0804
0805
Error message
Slave DMA Controller Error
DMA Controller Error
Fail-safe Timer NMI Failure
Software Port NMI Failure
Bus Time-out NMI in Slot
Expansion Board NMI in Slot
PCI System Error
PCI Parity Error
PCI System Error
System Board Device Resource Conflict
Static Device Resource Conflict
PCI Segment 1 memory request exceeds 998 MB
PCI Segment 1 I/O requests exceeds 12K
PCI I/O request exceeds amount available
PCI memory request exceeds amount available
Illegal bus for memory request below 1 MB
Memory request below 1 MB exceeds 1 MB
PCI I/O Port Conflict
PCI Memory Conflict
PCI IRQ Conflict
PCI Error Log is Full
PCI ROM not found, May Be OK For This Card:
Insufficient Memory to Shadow PCI ROM:
Continued
222
Chapter 10 Solving Problems
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 10-3. POST Error Codes and Messages (continued)
Code
0806
0809
0810
0811
0812
0815
0816
0817
0820
0900
0903
0905
0906
0982
0984
0985
0986
0987
Error message
Memory Allocation Failure for Second PCI Segment
PCI Error Log is Full
Floppy Disk Controller Resource Conflict
Primary IDE Controller Resource Conflict
Secondary IDE Controller Resource Conflict
Parallel Port Resource Conflict
Serial Port 1 Resource Conflict
Serial Port 2 Resource Conflict
Expansion board Disabled in Slot
NVRAM Checksum Error, NVRAM Cleared
NVRAM Data Invalid, NVRAM Cleared
NVRAM Cleared By Jumper
Password Cleared by Jumper
I/O Expansion Board NMI in Slot
Expansion Board Disabled in Slot
Fail-safe Timer NMI
System Reset caused by Watchdog Timer
Bus Time-out NMI in Slot
■ ■ ■
■ ■ ■
M440LX Server System Product Guide
223
Download from Www.Somanuals.com. All Manuals Search And Download.
224
Chapter 10 Solving Problems
Download from Www.Somanuals.com. All Manuals Search And Download.
Regulatory Specifications A
Declaration of the Manufacturer or Importer
The Intel Corporation hereby certifies that this product is in compliance
with EU EMC Directive 89/ 336/ EEC, using standards EN55022 Class B,
EN50082-1, and EN61000-3-2 (some server configurations are not equipped
to comply with this standard); EU low voltage directive, 73/ 23/ EEC, using
standard EN60950 and applicable amendments
Safety Compliance
USA: UL 1950, 3rd Edition
Canada: UL to CSA C22.2 No. 950-95
Europe: TUV to EN60950, ZH1/ 618, and ISO 9241
International: NEMKO to IEC950 (A1 + A2 + A3)
NEMKO to EN60950 (A1 + A2),
NEMKO to EMKO-TSE(74-SEC) 207/ 94
AS3260-1988
M440LX Server System Product Guide
225
Download from Www.Somanuals.com. All Manuals Search And Download.
Electromagnetic Compatibility (EMC)
USA: FCC 47 Class B CFR Parts 2 and 15, Class B via
declaration
Canada: Industry Canada (IC) ICES-003 Class B
Europe: EN55022
EN50082-1
IEC 801-2 ESD Susceptibility
IEC 801-3 Radiated Immunity
IEC 801-4 Electrical Fast Transient
EN61000-3-2
International: CISPR 22/ 93, Class B
Japan: VCCI Class 2 ITE
Australia: AS/ NZS 3548, AS/ NZS 4252.1
CE Mark
The CE marking on this product indicates that it is in compliance with the
European community’s EMC directive and Low Voltage directive.
Electromagnetic Compatibility Notice (USA)
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
•
Consult the dealer or an experienced radio/ TV technician for help.
226
Appendix A Regulatory Specifications
Download from Www.Somanuals.com. All Manuals Search And Download.
Any changes or modifications not expressly approved by the grantee of this
device could void the user's authority to operate the equipment. The
customer is responsible for ensuring compliance of the modified product.
Only peripherals (computer input/ output devices, terminals, printers, etc.)
which comply with FCC class B limits may be attached to this computer
product. Operation with noncompliant peripherals is likely to result in
interference to radio and TV reception.
All cables used to connect to peripherals must be shielded and grounded.
Operation with cables, connected to peripherals, which are not shielded and
grounded may result in interference to radio and TV reception.
The following pertains to certified processor modules:
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Note
✏
If a Class A device is installed within this system, then the
system is to be considered a Class A system. For example, a
connection to a Local Area Network (LAN) may cause this
system to operate as a Class A device. In this configuration,
operation of this equipment in a residential area is likely to
cause harmful interference.
M440LX Server System Product Guide
227
Download from Www.Somanuals.com. All Manuals Search And Download.
Electromagnetic Compatibility Notices (International)
English translation of the notice above:
This equipment is in the Class II category (information equipment to be
used in a residential area or an area adjacent thereto) and conforms to the
standards set by the Voluntary Control Council For Interference (VCCI) by
Data Processing Equipment and Electronic Office Machines aimed at
preventing radio interference in such residential area.
When used near a radio or TV receiver, it may become the cause of radio
interference.
Read the instructions for correct handling.
This equipment has been tested for radio frequency emissions and has been
verified to meet CISPR 22/ 93 Class B.
Cet appareil numérique respecte les limites bruits radioélectriques
applicables aux appareils numériques de Classe B prescrites dans la norme
sur le matériel brouilleur: “Appareils Numériques”, NMB-003 édictée par le
Ministre Canadian des Communications.
This digital apparatus does not exceed the Class B limits for radio noise
emissions from digital apparatus set out in the interference-causing
equipment standard entitled: “Digital Apparatus,” ICES-003 of the
Canadian Department of Communications.
■ ■ ■
■ ■ ■
228
Appendix A Regulatory Specifications
Download from Www.Somanuals.com. All Manuals Search And Download.
Equipment Log B
Use this equipment log to record pertinent information about your server
system. You will need some of this information when you run the System
Configuration Utility (SCU).
Record the model and serial numbers of the server system and the system
board. They are on the back panel of the server and along the left side of
the system board near the expansion slots.
Record the model and serial numbers of the system components, dates of
component removal or replacement, and the vendor’s name. Be sure to
record the same information for any components added to the system, such
as hard disk drives, add-in boards, or printers.
The location of serial numbers on add-in boards, hard disk drives, and
external equipment, such as video displays or printers, varies from one
manufacturer to another.
M440LX Server System Product Guide
229
Download from Www.Somanuals.com. All Manuals Search And Download.
Equipment Log
Manufacturer Name
and Model Number
Date
Installed
Component
Serial Number
System
System Board
Primary
Processor
Module
Secondary
Processor
Module
Memory
Module
RPX Module
Power Share
Backplane
SCSI
Hot-docking
Backplane #1
SCSI
Hot-docking
Backplane #2
Keyboard
Mouse
Floppy Disk
Drive A
Continued
230
Appendix B Equipment Log
Download from Www.Somanuals.com. All Manuals Search And Download.
Equipment Log (continued)
Manufacturer Name
and Model Number
Date
Installed
Component
Serial Number
Floppy Disk
Drive B
Tape Drive
CD-ROM
Drive
Hard Disk
Drive 1
Hard Disk
Drive 2
Hard Disk
Drive 3
Hard Disk
Drive 4
Hard Disk
Drive 5
Hard Disk
Drive 6
Hard Disk
Drive 7
Hard Disk
Drive 8
Hard Disk
Drive 9
Hard Disk
Drive 10
■ ■ ■
■ ■ ■
M440LX Server System Product Guide
231
Download from Www.Somanuals.com. All Manuals Search And Download.
|