Intel® Server RAID Controller U2-1 (SRCU21)  
Quick Start Guide  
Before You Begin  
Introduction  
Items Provided on the Intel® Server RAID Controller U2-1 CD-ROM  
Intel Server RAID Controller U2-1 Hardware Setup  
Intel Integrated RAID Software Setup and Installation  
Setup and Installation for Novell NetWare...........................................13  
Setup and Installation for UnixWare7.1...............................................17  
Getting Help  
Translations of this guide are available at:  
Übersetzungen dieses Handbuchs sind erhältlich bei:  
Versiones traducidas de esta guía se encuentran disponibles en:  
Des traductions de ce guide sont disponibles à l'adresse:  
Le versioni tradotte di questa Guida sono disponibili presso:  
As traduções deste guia estão disponíveis em:  
Переводы данного руководства можно найти по адресу:  
Copyright © 1999 Intel Corporation. All rights reserved. No part of this document may be  
copied, or reproduced in any form, or by any means without prior written consent of Intel.  
Intel Corporation (Intel) makes no warranty of any kind with regard to this material, including,  
but not limited to, the implied warranties of merchantability and fitness for a particular  
purpose. Intel assumes no responsibility for any errors that may appear in this document.  
Intel makes no commitment to update nor to keep current the information contained in this  
document.  
Third-party brands and trademarks are the property of their respective owners.  
Order Number: A06952-002  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cautions and Warnings  
WARNINGS  
This guide is for qualified technical personnel with experience  
installing and configuring PCI adapter cards.  
Read and adhere to all warnings, cautions, and notices in this guide  
and the documentation supplied with this product.  
CAUTION  
Take precautions to prevent electrostatic discharge (ESD) damage before  
handling the Intel Server RAID Controller U2-1 Adapter Card.  
Electrostatic discharge (ESD) can damage adapter card components.  
Perform the described procedures only at an ESD workstation. If no such  
station is available, you can provide some ESD protection by wearing an  
antistatic wrist strap and attaching it to a metal part of the computer  
chassis.  
Intel Server RAID Controller U2-1 (SRCU21) Quick Start Guide  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Introduction  
The Intel® Server RAID Controller U2-1 (SRCU21) combines i960® I/O  
processor based hardware, firmware and an easy to use interface. The SRCU21  
runs the Intel Integrated RAID software.  
This guide provides an introduction to Intel® Integrated RAID software and  
provides a set of instructions to install and configure the Intel SRCU21. For  
detailed information on installing and configuration the Intel SRCU21, please  
refer to the Intel Server RAID Controller U2-1 User's Manual located on the  
CD-ROM included with this product.  
Product Check List  
The following hardware and software components are supplied with the standard  
shipping package:  
Intel Server RAID Controller U2-1  
Intel Server RAID Controller U2-1 CD-ROM  
Intel Server RAID Controller U2-1 Quick Start Guide  
Items Provided on the Intel Server RAID Controller U2-1  
CD-ROM (bootable)  
Intel Server RAID Controller U2-1 User' Manual  
Intel Integrated RAID Software  
Firmware  
Drivers (OSM's)  
Utilities (Firmware, Make Diskettes, Troubleshooting etc.)  
Monitor Application  
Storage Console  
DMI Component Instrumentation  
SNMP Extension Agent  
The Intel Server RAID Controller U2-1 User' Manual is provided on the  
CD-ROM in an online/html format (at <cdromdrive>:\DOCS\COVER.HTM)  
viewable with any HTML-compatible browser, such as Microsoft Internet  
Explorer or Netscape Navigator. The User's Manual can also be displayed and  
printed using AdobeAcrobatReader.  
Hardware/Software Installation Overview  
Begin  
Installation of  
OS on a  
Intel Integrated  
RAID  
Volume  
Create Bootable  
Gather Required  
Hardware  
and  
RAID Volume  
Using RAID  
Configuration  
Utility  
Install  
Adapter Card  
Software  
Run  
Intel Integrated  
RAID  
Create OS  
Installation  
Drivers  
Install OS on a  
RAID Volume  
Setup  
Diskette  
4
Intel Server RAID Controller U2-1 (SRCU21) Quick Start Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Intel Server RAID Controller U2-1 Adapter Card  
C
D
A
E
B
F
G
I
H
J
K
A7469-01X  
A
B
C
D
External VHDCI Connector  
Internal 68-pin Connector  
G
H
I
Flash Recovery  
(FRU) Jumper  
JTAG Port  
(Debug)  
SDRAM DIMM Socket  
ECC 66 MHz or PC100  
PCI 32-bit, 33 MHz  
Intel i960 RM I/O Processor  
100MHz Core  
J
Ultra2 SCSI  
1 Channel  
Hardware XOR  
LSI Logic SYM53C895  
E
F
SCSI Activity LED  
16 Mb Flash  
K
SDRAM DIMM  
Intel Server RAID Controller U2-1 (SRCU21) Quick Start Guide  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intel Server RAID Controller U2-1 Hardware  
Setup  
Hardware Requirements  
Server with CD-ROM Drive not attached to Intel Server RAID  
Controller U2-1  
One available PCI slot (33MHz recommended)  
Monitor display resolution of 800 x 600 or higher  
Intel Server RAID Controller U2-1 Adapter Card  
PCI 2.2 Compliant BIOS  
Installing Intel Server RAID Controller U2-1 into a System  
The Intel Server RAID Controller U2-1 comes with the Intel Integrated RAID  
firmware already programed into the flach memory. All that is necessary before  
installing the SRCU21 adapter into the Intel server board is to install an  
approved SDRAM ECC DIMM into the memory socket. Install an appropreate  
DIMM into the memory socket as indicated in the diagram on the previous page.  
Please refer to the approved memory list at:  
WARNING  
SHOCK HAZARDS may be present inside the unit in which this card  
is being installed. Disconnect all power cords to the unit before  
removal of any covers.  
Follow the warnings noted in your computers user or service manual  
before installing this board. ONLY after all the covers are reinstalled  
should you reattach the power cords and power up the unit for the  
software installation and use.  
1
2
Power down the system, disconnect power cord(s) and remove the system  
cover.  
Install the SRCU21 into an available PCI slot. Connect one end of the  
SCSI cable to the internal (68 pin) or external (VHDCI) SCSI connector on  
the SRCU21. Connect the other end of the SCSI cable to the SCSI drives  
or drive enclosure.  
3
Replace the system cover, reconnect power cord(s).  
NOTE  
SRCU21 will work in a 66MHz slot, however, a 33MHz PCI slot is  
recommended. Consult the system guide for the target server board to  
determine an appropriate 33MHz PCI slot.  
6
Intel Server RAID Controller U2-1 (SRCU21) Quick Start Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
NOTE  
Ensure that the end of the SCSI bus is properly terminated. Consult the  
documentation for the drives or drive enclosure for termination details.  
Intel Integrated RAID Software Setup and  
Installation  
This section details installation of supported operating systems to a RAID  
volume controlled by the SRCU21. Operating systems can also be installed to a  
pass-through drive (drive attached to SRCU21, but controlled directly by the  
host) or to a drive connected to a different controller. For operating system  
installation instructions on pass-through drives and drives attached to another  
controller, refer to the Intel Server RAID Controller U2-1 User's Manual.  
Create a RAID Volume for the Operating System  
A volume (or logical drive) must be set up prior to installing an operating  
system. The volume created in this step will host the appropriate operating  
system. Ensure that the volume's size is large enough to contain the operating  
system. The volume may contain more than just the host operating system if  
desired.  
Create and configure the operating system RAID volume (boot volume) using  
the RAID Configuration Utility (RCU).  
1
2
3
Turn on target system with the SRCU21 installed. During system boot-up,  
the message Press Ctrl C to run the RAID Configuration Utility appears  
in the display. Press Ctrl-C when this message appears, to execute the  
RAID Configuration Utility (RCU).  
Follow the screen instructions to create and configure a RAID volume.  
Ensure that the volume is designated as the boot device when creating the  
volume (you can verify it is the boot volume after it has been created by  
using the custom configuration menu option in the main menu of the RCU).  
Reboot when finished and proceed to the appropriate section to install the  
desired operating system. For more information on using the RCU please  
refer to the Intel Server RAID Controller U2-1 User's Manual.  
NOTE  
The RCU is designed to create one volume for the host operating system,  
and therefore contains only a subset of the RAID configuration features.  
The RCU is limited to the creation of one RAID volume across all available  
drives. When using the RCU to create a volume using fewer than all disks  
attached to the SRCU21, first mark drives that will not be used in the RAID  
volume as pass-through. These drives can be changed to be non-pass-  
through drives after the volume has been created. The Storage Console  
application is the primary management tool and provides all RAID  
configuration options (including creation of more that one RAID volume).  
For instructions on using Storage Console, please refer to chapter 4 in the  
Intel Server RAID Controller U2-1 User’s Manual.  
Intel Server RAID Controller U2-1 (SRCU21) Quick Start Guide  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
CAUTION  
Do not install OSMs (Operation System Service Modules) downloaded  
from OS vendor websites. An OSM is the operating system half of the I²O  
split driver model. The OSMs provided on the Intel Integrated RAID  
CD-ROM are a later version than the OSMs currently provided by OS  
vendors. Using OSMs other than those provided on the Intel Integrated  
RAID CD-ROM may yield unpredictable results.  
8
Intel Server RAID Controller U2-1 (SRCU21) Quick Start Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setup and Installation for Microsoft Windows NT Server  
Software Requirements  
Intel Integrated RAID CD-ROM  
Hard Disk Space: 9 MB Minimum  
Windows NT Installation Diskette (Microsoft Windows NT SCSI Miniport  
Diskette)  
Microsoft Windows NT Server 4.0 including Microsoft Internet  
Information Server 2.0*  
Microsoft Windows NT 4.0 Service Pack 5 or greater*. (Service Pack 5  
will automatically upgrade Internet Information Server 2.0 to Internet  
Information Server 3.0.)  
Microsoft Internet Explorer 4.01 Service Pack 1 (recommended) or greater  
or Netscape Navigator 4.05 or greater*  
*
Not supplied  
NOTE  
Microsoft Internet Information Server 4.0 may also be required (instead of  
Microsoft Internet Information Server 3.0) for servers that will be used to  
host web sites. These servers typically require the advanced features  
and security provided with Microsoft Internet Information Server 4.0. See  
the Intel Server RAID Controller U2-1 User's Manual for instructions on  
setting up SRCU21 with Microsoft Internet Information Server 4.0.  
NOTE  
Microsoft Internet Explorer with Service Pack 1 can be downloaded from  
Microsoft Windows NT 4.0 Option Pack (available as web download  
or CD).  
Installing Microsoft Windows NT Server on a Intel Integrated  
RAID Volume  
This procedure installs Microsoft Windows NT Server on an Intel Integrated  
RAID volume.  
1
Create a Microsoft Windows NT SCSI Miniport Diskette: Insert the Intel  
Integrated RAID CD-ROM into the target system and restart the system to  
boot from the CD-ROM. When the ROM-DOS Startup Menu appears  
select option #1 Make Diskettes. When the Select a diskette to create”  
screen appears, select Windows NT Installation. A command window  
then appears. Insert a blank high-density diskette in drive A: and press  
Enter to create the Windows NT SCSU Miniport Diskette. Alternatively  
the CD-ROM can be inserted into a system already running Windows 95,  
98 or NT. The CD-ROMs auto-runfeature will bring up a menu that  
will allow creation of the Miniport Diskette.  
Intel Server RAID Controller U2-1 (SRCU21) Quick Start Guide  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2
Install the following required software:  
a. Microsoft Windows NT Server 4.0  
Select the scenario below (1 or 2) which matches your installation to  
complete the Microsoft Windows NT SCSI diskette miniport driver  
installation.  
1. If you are installing NT with boot disks (booting from diskettes  
initially to setup NT), during install let NT detect the storage  
devices in your system. When device detection is complete,  
select Sto specify additional storage devices, then select  
Other. Insert the Microsoft Windows NT SCSI Miniport  
Diskette (created in step 1 above) in the floppy drive. Press  
Enter to select the I2O Miniport Driverand continue with the  
NT installation. Go to step b.  
2. If you are installing NT without boot disks, for example, you are  
booting with the NT Server CD-ROM, press F6 as soon as the  
blue screen appears to ensure that the Microsoft Windows NT  
bypasses mass storage controller detection. When prompted to  
specify a mass storage controller, select Sto specify additional  
storage devices and then select Other. Insert the Microsoft  
Windows NT SCSI Miniport Diskette (created in step 1 above) in  
the floppy drive. Press Enter to select the I2O Miniport  
Driverand continue with the NT installation. Go to step b.  
b. During the Windows NT Server 4.0 installation install:  
TCP/IP  
Microsoft Internet Information Server 2.0 (TCP/IP must be  
installed prior to installing Internet Information Server).  
c. After completing the NT installation, install the following components  
and software:  
Microsoft Windows NT 4.0 Service Pack 5 or greater. (This will  
automatically upgrade Internet Information Server 2.0 to Internet  
Information Server 3.0.)  
Microsoft Internet Explorer 4.01 Service Pack 1 (recommended)  
or greater or Netscape Navigator 4.05 or greater.  
NOTE  
If your browser is configured to use a proxy server, ensure that it is  
configured to bypass the proxy server for local addresses. See the User's  
Manual for details on configuring a browser to bypass the proxy server for  
local addresses.  
NOTE  
Due to added security in Intel Integrated RAID, anonymous connections  
must be disabled in Microsoft Internet Information Server in order to  
execute the Intel Integrated RAID Storage Console in NT.  
10  
Intel Server RAID Controller U2-1 (SRCU21) Quick Start Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
Configure Microsoft Internet Information Server 3.0  
a. Start Internet Service Manager from the Microsoft Internet Server  
program group.  
b. Double-click on the server name in the WWW Service row (top  
computer name).  
c. Under the Service tab in the WWW Service Properties window clear  
the Allow Anonymous checkbox in the Password Authentication  
section. See the figure below.  
WWW Service Properties  
d. Select OKand close Internet Service Manager.  
NOTE  
If you use Netscape Navigator as the default browser on an NT system  
where Intel Integrated RAID is installed, you will have to enable Basic  
Authentication in Microsoft Internet Information Server to use the Intel  
Integrated RAID Storage Console. Netscape Navigator does not support  
Windows NT Challenge/Response authentication. Please follow the  
instructions in the Intel RAID User's Manual to enable Windows NT  
Challenge/Response if you are using Netscape Navigator.  
Intel Server RAID Controller U2-1 (SRCU21) Quick Start Guide  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
Install the Intel Integrated RAID software (run the Intel Integrated RAID  
setup). The system should be powered on and logged into NT with an  
administrators account before proceeding.  
NOTE  
You must have administrative level permissions to install Intel Integrated  
RAID software.  
a. Insert the Intel Server RAID Controller U2-1 CD-ROM in the  
CD-ROM drive. (If the RAID Installer Menu does not appear, then  
run the setup.exe file that resides at:  
<CD-ROM root>\os_setup\winnt\setup.exe on the CD-ROM and skip  
step B.)  
b. Click on the Setup button. See the following figure. Follow the on-  
screen prompts to complete installation.  
Intel Integrated RAID Installer Main Menu  
c. The four components in the "preselected components" window below  
are preselected. Accept this configuration by clicking on Next.  
12  
Intel Server RAID Controller U2-1 (SRCU21) Quick Start Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preselect Components  
NOTE  
The DMI and SNMP components are not selected by default.  
NOTE  
Refer to section “Intel Integrated RAID Software Component Installation”  
in chapter 4 of the Intel Server RAID Controller U2-1 User's Manual for  
information on HP Openview and RAID Monitor.  
5
See Section 4.5 in the Intel Server RAID Controller U2-1 User's Manual to  
customize your RAID volumes using Storage Console.  
Setup and Installation for Novell NetWare  
Software Requirements  
Intel Server RAID Controller U2-1 CD-ROM  
Hard disk space: minimum 4 MB  
MS-DOS 6.22 or earlier* (Novell 4.2 only)  
NetWare Installation Diskette  
Novell NetWare 4.2 with Service Pack 6 or higher or Novell NetWare 5.0  
with Service Pack 2a or higher*  
*
Not supplied  
Intel Server RAID Controller U2-1 (SRCU21) Quick Start Guide  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing Novell NetWare on a RAID Volume  
Follow the required procedure below to install Intel Integrated RAID. There are  
two procedures listed below (one for each supported version of NetWare).  
Please follow the instructions for the version you wish to install  
(version 4.2 or 5.0).  
NetWare 4.2  
1
Create a NetWare Installation Diskette: Insert the Intel Integrated RAID  
CD-ROM into the target system and restart the system to boot from the  
CD-ROM. When the ROM-DOS Startup Menu appears select option #1  
Make Diskettes. When the Select a diskette to createscreen appears,  
select NetWare Installation. A command window appears. Insert a  
blank high-density diskette in drive A: and press Enter to create the  
NetWare Installation Diskette. Alternatively the CD-ROM can be inserted  
into a different system running Windows 95, 98 or NT. The CD-ROMs  
auto-runfeature will bring up a menu that will allow creation of the  
NetWare Installation Diskette.  
2
3
Insert MS-DOS floppy and reboot. Once you reboot, you will have to run  
FDISK to create a DOS partition of at least 50MB on the newly created  
volume (make sure it is flagged as the Activepartition). Reboot and  
format the new partition. Make the new partition bootable.  
Copy the desired MS-DOS files to the hard drive, copy the necessary  
CD-ROM drivers (e.g. ATAPI_CD.SYS and MSCDEX.EXE) and create a  
CONFIG.SYS and AUTOEXEC.BAT that loads those drivers.  
Additionally, insert the following lines in the CONFIG.SYS file:  
files=30  
buffers=20  
4
5
Reboot the server, insert the NetWare Installation CD-ROM, go to the  
appropriate drive letter and run INSTALL.BAT.  
After booting you will first be asked to Accept the License Agreement. Do  
so and then select NetWare 4.2, then select Custom installation of  
NetWare 4.2. Enter the server name and internal network number. Hit  
Enter to begin the initial file copy.  
6
Confirm the locale configuration and select Continue. Modify the  
NCF files. Make any desired modifications. Next, the device driver  
installation screen appears.  
7
8
Choose Select additional or modify selected Disk/LAN drivers.  
Choose Select an additional driver. Hit Insert to install an unlisted  
driver. Make sure that the NetWare Installation diskette is in the floppy  
drive and hit Enter. Select BKSTROSM.HAMfrom the list.  
9
Continue with the NetWare installation as normal by following the screen  
prompts.  
10 Once the server installation is finished, complete the installation of the Intel  
Integrated RAID software suite by following the steps below.  
11 Run "LOAD INSTALL".  
14  
Intel Server RAID Controller U2-1 (SRCU21) Quick Start Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 Select "Product Options", then "Install product not listed". It will tell you  
that it is going to scan the A: drive for installation scripts. Ensure the  
"NetWare Installation" diskette is in the floppy drive, hit Enter to  
continue.  
13 A screen prompt will ask which components you wish to install. Select the  
desired components, and hit F10 to continue. The appropriate files will be  
copied and the AUTOEXEC.NCF and STARTUP.NCF files modified as  
necessary.  
CAUTION  
Once the product is installed, check for and remove any duplicate lines in  
STARTUP.NCF. For example, NetWare 4.2 installations may insert an  
extra load line for the module PK411.NLM. Remove the extra line.  
14 After the installation is complete, reboot the server to load the new drivers.  
15 See Section 4.5 in the Intel Server RAID Controller U2-1 User's Manual to  
customize your RAID volumes using Storage Console.  
NetWare 5  
NOTE  
If you do not use the boot capability of the NW5 CD, then replace step 2-5  
below with steps 2-4 of the NetWare 4.2 instructions above.  
1
Create a NetWare Installation Diskette: Insert the Intel Integrated RAID  
CD-ROM into the target system and restart the system to boot from the  
CD-ROM. When the ROM-DOS Startup Menu appears select option #1  
Make Diskettes. When the Select a diskette to createscreen appears,  
select NetWare Installation. A command window then appears. Insert a  
blank high-density diskette in drive A: and press Enter to create the  
NetWare Installation Diskette. Alternatively the CD-ROM can be inserted  
into a different system running Windows 95, 98 or NT. The CD-ROMs  
auto-runfeature will bring up a menu that will allow creation of the  
NetWare Installation Diskette.  
2
Insert the NetWare CD-ROM and reboot.  
NOTE  
The CMOS may need to be edited on some systems to be set to boot from  
the CD-ROM. Otherwise, if the system finds a partition on the hard drive it  
will attempt to boot from it and an error will result.  
3
4
After booting you will first be asked to Accept the License Agreement. Do  
so. For a brand new volume, you should then select Create a New Boot  
Partition.  
NetWare will then ask for the size of the boot partition, you can either keep  
the default of 50MB or hit Modify to change the size to suit your needs.  
When you are done, select Continue.  
Intel Server RAID Controller U2-1 (SRCU21) Quick Start Guide  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
6
It will ask you confirm the boot partition creation. Select Continue. You  
will then press a key to reboot.  
When NetWare boots again, it will first format the newly created boot  
partition, and then start loading files. During this initialization, you will  
see a white graphical NetWare logo screen.  
7
8
It will eventually load a Welcome screen, asking you to verify the startup  
directory (C:\NWSERVER). Hit Alt F10 to exit the installation. At the  
console, type Down. The installation exits to the boot drive prompt.  
Insert the NetWare installation diskette into the A: drive. If your boot  
drive is C:, then run NWUPDATE.BAT. If your boot drive is other than  
C:, then create an NWUPDATE subdirectory and copy all the files from  
A:\DRIVERS into the NWUPDATE subdirectory.  
9
Remove the diskette from the A: drive and reboot the server. After booting  
you will be asked to Accept the License Agreement. Do so and then select  
Continue with Existing Partition. You are now ready to install  
NetWare 5 on the Intel Integrated RAID volume.  
10 Continue with the NetWare installation as normal by following the screen  
prompts. Select the Block Storage OSMwhen prompted.  
11 Reboot the server and install Service Pack 2a or higher. Once the server  
installation is completed, reboot the server.  
12 Install the Intel Integrated RAID software (run the Intel Integrated RAID  
setup).  
13 Run "NWCONFIG".  
14 Select "Product Options", then "Install product not listed". It will tell you  
that it is going to scan the A: drive for installation scripts. Ensure the  
"NetWare Installation" diskette is in the floppy drive, hit Enter to  
continue.  
15 A screen prompt will ask which components you wish to install. Select all  
of the components and hit F10 to continue.  
BKSTROSM.HAM  
SCSIOSM.HAM  
HTTP and Winsock Services  
RAID Management Agents  
The appropriate files are copied and the AUTOEXEC.NCF and  
STARTUP.NCF files are modified as necessary.  
16 After the installation is complete, reboot the server to load the new drivers.  
17 See Section 4.5 in the Intel Server RAID Controller U2-1 User's Manual to  
customize your RAID volumes using Storage Console.  
16  
Intel Server RAID Controller U2-1 (SRCU21) Quick Start Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setup and Installation for UnixWare 7.1  
Software Requirements  
SCO UnixWare 7.1 software with Netscape 4.08 or greater included *  
Intel Server RAID Controller U2-1 CD-ROM  
Hard disk space: minimum 20 MB  
UnixWare Installation Diskette  
*
Not supplied  
Installing UnixWare on a RAID Volume  
Follow the required procedure below to install Intel Integrated RAID.  
1
Create a UnixWare Installation Diskette: Insert the Intel Integrated RAID  
CD-ROM into the target system and restart the system to boot from the  
CD-ROM. When the ROM-DOS Startup Menu appears select option #1  
Make Diskettes. When the Select a diskette to createscreen appears,  
select UnixWare Installation. A command window then appears. Insert  
a blank high-density diskette in drive A: and press Enter to create the  
UnixWare Installation Diskette. Alternatively the CD-ROM can be  
inserted into a different system running Windows 95, 98 or NT. The  
CD-ROMs auto-runfeature will bring up a menu that will allow creation  
of the UnixWare Installation Diskette.  
2
Insert UnixWare 7.1 Volume: 1 of 2 diskette and reboot. Install the OS  
using the install instruction provided in UnixWare 7 Installation Guide  
Manual. UnixWare will prompt you to install Host Bus Adapter diskette.  
At that time insert the UnixWare Installation Diskette when prompted.  
NOTE  
During the installation of UnixWare, you will be prompted to install the  
Network Information Services (NIS) package. By default the installation  
will configure your system as an NIS client. See your system  
administrator for configuration of the NIS services.  
After the installation, files such as /etc/inet/inetd.conf are supposed to be  
distributed to the client via NIS. If, however, you don't have a master NIS  
server on the network, the client will be unable to retrieve its copy of this  
(and other) file(s). Depending on the particular service being requested,  
fulfilling the request may take a long time, or may fail completely.  
If you do not plan on using NIS, defer installation of NIS during the  
installation by pressing F8 on the NIS configuration screen. If you decide  
at a later time to install NIS, you can do so using the pkgadd(1) command.  
3
Install the Netscape browser. The Netscape browser is provided in the  
SCO UnixWare CD-ROM Disk 2 of 3.  
Intel Server RAID Controller U2-1 (SRCU21) Quick Start Guide  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4
5
After completing the UnixWare installation insert the Intel Server RAID  
Controller U2-1 CD-ROM in the CD-ROM drive and mount the CD-ROM.  
a. Create a directory to mount the file. For example, type mkdir  
cdfilesat the prompt.  
b. Mount the CD-ROM to the folder by typing mount F cdfs r  
/dev/cdrom/cdrom1 /cdfiles”  
Install all the Packages/Services Requirements first before installing the  
components packages. The following table lists the installation  
components and preinstallation requirements provided by Intel Integrated  
RAID for UnixWare.  
Installation Components and Preinstallation Requirements  
Component  
Package  
Name  
Packages/  
Services  
Requirements  
Component  
Name  
Optional  
Packages  
Note  
SNMP  
Extension  
Agent  
raidxa  
Snmpd,  
N/A  
Snmpd service  
provided with the  
UnixWare  
CD-ROM. A  
typical  
i2OosM,  
ptf7066a,  
ptf7429a  
installation  
should have the  
snmpd service  
running.  
Raid Monitor  
raidmon  
raiddoc  
i2oOSM,  
ptf7066a,  
ptf7429a  
N/A  
N/A  
RAID  
Web Browser  
Install the web  
browser from the  
UnixWare  
Documentation  
Installation  
CD-ROM.  
Storage  
Console  
i2oOSM,  
ptf7066a,  
ptf7429a  
inetd & Web  
Browser  
N/A  
By default inetd  
is installed and  
started. Install  
the web browser  
from the  
UnixWare  
Installation  
CD-ROM.  
18  
Intel Server RAID Controller U2-1 (SRCU21) Quick Start Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Optional Installation Components  
Component  
Component  
Name  
Package  
Name  
Packages/Services  
Requirements  
Optional  
Packages  
Note  
Component  
Instrumentation  
raidci  
Dmi, i2oOSM,  
ptf7066a, ptf7429a  
DMIman,  
DMIdoc  
DMI  
services  
installation  
only  
6
Launch the installer by typing the following:  
a. Type cd /cdfiles/os_setup/unixware”  
b. Type sh installto start the install script. The launched scripts are  
shown in the following figure.  
Launched Scripts  
c. Select option 1 (by typing 1) to install the requirements and  
components. See the figure above.  
Intel Server RAID Controller U2-1 (SRCU21) Quick Start Guide  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Install Components  
Packages can be individually installed by typing the package number  
listed on the screen as shown in the figure above. To select all  
packages, press Enter. To install multiple packages, type <package  
number>, <package number> etc. For example, 1,2,3,6 etc., then  
press Enter. After completing the installation type quit and hit  
Enter to return to the main menu. Packages which have been  
previously installed will only be updated if the revision number of the  
currently installed package is older or newer.  
7
After completing the installation of the components launch the application  
using the commands in the following table.  
Component Launch Commands  
Component  
Name  
Path to Add in  
.cshrc File  
Launch by Typing  
Component  
/opt/rss/bin  
Type raidci(if path is set)  
Instrumentation  
SNMP  
/opt/rss/bin  
Type .iraidxa(if path set)  
Extension  
Agent  
RAID Monitor  
/opt/rss/bin  
Type .raidmon(if path set)  
Documentation  
/opt/rss/docs  
Type raiddoc(if path is set) or  
Type netscape /opt/rss/docs/cover.htm”  
Storage  
Console  
N/A  
Launch the browser and type the following in  
the http address box:  
20  
Intel Server RAID Controller U2-1 (SRCU21) Quick Start Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Getting Help  
World Wide Web  
Telephone  
Talk to a Customer Support Technician** (Intel reserves the right to change  
pricing for telephone support at any time without notice).  
In U.S.: 1-900-555-5800 (MF, 7:00 am5:00 pm, Th 7:00 am3:00 pm, PST).  
Calls billed at U.S. $2.50 per minute.  
In U.S. and Canada: 1-800-404-2284 (MF, 7:00 am5:00 pm,  
Th 7:00 am3:00 pm, PST). Credit card calls billed at U.S. $25 per incident.  
In Europe:  
English language: +44-131-458-6847  
French language: +44-131-458-6848  
German language: +44-131-458-6954  
Italian language:  
+44-131-458-6951  
(M, Th, F, 8:00 am5:00 pm, TW, 8:00 am4:00 pm, UK time)  
Credit card calls billed at U.S. $25 per incident (levied in local currency at the  
applicable credit card exchange rate plus applicable VAT).  
In Asia-Pacific region (Singapore local time, OctApril: MF, 6:00 am4:00 pm;  
AprilOct: MF, 5:00 am4:00 pm).  
Credit card calls billed at U.S. $25 per incident.  
Australia (Sydney): +1-800-649-931  
Hong Kong:  
Korea:  
+852-2-844-4456  
+822-767-2595  
+852-2-844-4456  
+65-831-1311  
PRC:  
Singapore:  
Taiwan:  
+886-2-718-9915  
Rest of the world: Call the North American Service Center at +1-916-377-7000  
(MF, 7:00 am5:00 pm, U.S. pacific standard time).  
Credit card calls billed at U.S. $25 per incident.  
** Or contact your local dealer or distributor.  
Technical Training & Support  
If you are registered in the Intel Processor Dealer Program (North America), the  
Genuine Intel Dealer Program (Asia-Pacific Region), or the Intel Processor  
Integrator Program (Europe/Latin America), you are eligible for technical training  
and support.  
In U.S. and Canada: 1-800-538-3373, ext. 442 (MF, 5:00 am5:00 pm, PST)  
In Europe: contact your distributor or fax your details to European Literature on  
+44 (0) 1793 513142.  
In Asia: +65-831-1379 (MF, 8:30 am5:30 pm, Singapore local time) or via  
Intel Server RAID Controller U2-1 (SRCU21) Quick Start Guide  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

Indesit Refrigerator IN S 1611 UK User Manual
Insignia Car Satellite TV System VS32D420NA16 User Manual
Intel Computer Hardware PXP43 User Manual
Invacare Mobility Aid 00 313 User Manual
ION Electronic Keyboard Piano Master User Manual
Juniper Networks Network Router V10000 User Manual
Kenmore Oven 7904802 User Manual
Kicker Home Theater System IX5002 User Manual
KitchenAid Washer Dryer KEYE800T User Manual
Kodak Digital Camera 8029340 User Manual