| OPERATOR’S MANUAL   67386   INCLUDING: OPERATION, INSTALLATION & MAINTENANCE   RELEASED: 3-28-06   REVISED:   (REV. 03)   8-2-10   CYCLE SENSOR KITS   (CLOSED ELECTRICAL CONTACT TYPE)   FOR 3/8” & 1/2” DIAPHRAGM PUMPS   CYCLE SENSOR KITS   67386 SENSOR INSTALLATION   67386 can be used on the following diaphragm pumps:   3/8” -- PD03P-XXX-XXX   1/2” -- PD05A-XXX-XXX-B, PD05P-XXX-XXX-B and PD05R-XXX-   XXX-B   Refer to figure 4.   1. Remove (134) bolts from the major valve and remove (135) valve   block.   2. Remove (141) valve plate and (140) valve insert from the valve   block.   3. Remove (136) plug and (111) spool. Assemble 67407 spool and   (136) plug into valve block. NOTE: Apply Lubriplate (94276) to all   “O” rings, “U” cups and mating parts.   4. Replace (140) valve insert and (141) valve plate in valve block.   NOTE: Assemble (140) valve insert with “dished” side toward (141)   valve plate.   5. Assemble 96563 adapter (with 95276 sensor attached) to valve   block. Attach (135) valve block to (101) motor body, using (134)   bolts. NOTE: Torque to 15 - 20 in. lbs (1.7 - 2.3 Nm).   GENERAL DESCRIPTION   The ARO diaphragm pump cycle sensor kits provide a closed contact   output each time the pump completes a cycle. This signal may be used   to record cycles for maintenance purposes or batching if the discharge   volume of each complete cycle is known.   Some parts of the pump must be replaced with those includedin thekits   to enable the activation of the switch.   OPERATION   140   132   141 k   Maximum Operating Voltage - 200 V DC.   Switching Current - 0.5 Amps   Once the kit is installed in the pump, it may be interfaced with a control   device in the following ways:   As a SOURCING switch (see figure 1) for use with PLC’s.   As a SINKING switch (see figure 2) for use with PLC’s.   As a closed contact switch (see figure 3) for use with meters.   . 134   135   Sourcing Switch   +V   Identification dot this side.   INPUT   111   136   Figure 1   g 67407   Sinking Switch   INPUT   Y325-29 (2) g   95276 g   Figure 2   96563 g   Closed Contact Switch   Included but not shown:   94276 Lubriplate grease   95275 Magnet   INPUTS   Figure 3   k Assemble with identification dot toward (132) gasket.   .Torque to 15 - 20 in. lbs (1.7 - 2.3 Nm).   g Included in 67386 kit.   Figure 4   INGERSOLL RAND COMPANY LTD   209 NORTH MAIN STREET – BRYAN, OHIO 43506   FAX(800) 892-6276   (800) 495-0276   © 2010   CCN 15257850   Download from Www.Somanuals.com. All Manuals Search And Download.   |