| VBN2, VBN3   Control Ball Valve/Actuator   Assemblies   INSTALLATION INSTRUCTIONS   INSTALLATION   5. Stem rotation:   When Installing this Product...   a. For two-way valves:   1. Read these instructions carefully. Failure to follow   them could damage the product or cause a   hazardous condition.   (1) Clockwise to close.   (2) Counterclockwise to open.   b. For three-way valves:   2. Check ratings given in the product data literature   and on the product to ensure the product is suit-   able for your application.   3. Installer must be a trained, experienced, licensed   service technician.   4. After installation is complete, check out product   operation as provided in these instructions.   (1) Clockwise to increase B to AB flow.   (2) Counterclockwise to increase A to AB flow.   6. Valve must be mounted with the actuator/bracket   above the valve body. Do not install the valve with   the stem below horizontal or upside down. (See   Fig. 1 and 2.)   Preparation   CAUTION   Equipment Damage Hazard.   Foreign particles like dirt and metal chips can   damage the ball seals.   Clean upstream lines prior to installation.   CAUTION   Equipment Damage Hazard.   Improper chemicals can damage the valve.   Use neither aerosol products nor petroleum-   based lubricants.   M29518   Fig. 1. Vertical valve installation.   1. Clean the lines upstream of particles larger than   1/16 in. diameter. Open valves fully. Flush entire   hydronic system of contaminants (welding slag,   solder, scale, metal chips, etc.) and chemically   treat water according to local conditions prior to   operation.   85   85   2. Proceed with installation once the system specifics   (expansion/contraction of the system and its   medium as well as operating pressures) are within   tolerances.   M29519A   3. Eliminate air from system.   4. Two-way valves are marked to show flow direction.   Fig. 2. Acceptable valve angle from vertical.   IMPORTANT   Flow arrows must point in the direction of the   flow for proper operation.   NOTE: For three-way valve mounting, see Fig. 3   through 5.   62-0197-04   VBN2, VBN3 CONTROL BALL VALVE/ACTUATOR ASSEMBLIES   OPERATION AND CHECKOUT   Once both the mechanical and electrical installations are   complete:   1. Cycle the actuator to verify that the direction of rota-   tion suits the control sequence.   HANDLE (REMOVABLE) FOR   MANUALLY ROTATING SHAFT   1 2. If the rotation direction is incorrect:   a. For 2-position control actuators: Remount actu-   ator on the bracket.   SCREWS (2)   1 b. For floating control actuators: Reverse two con-   trol signal wires (CW/CCW).   c. For analog control actuators either:   (1) Reposition reverse/direct acting switch, or   (2) Remount actuator on the bracket.   STEM ASSEMBLY COVER   1 3. If the control scheme requires fail-safe operation,   ensure that, upon removal of power, the valve   rotates to the desired position.   4. Spring return actuators are factory-configured for   A-port normally-closed fail-safe operation. To   change this to normally-open, remove and reinstall   STEM ASSEMBLY   1 BOLT   1 ANTI-ROTATION   the actuator in the opposite orientation as follows:   (a) Loosen the shaft coupling bolt using a 10   mm wrench.   BRACKET   1 SCREWS (2)   1 BOLT   1 (b) Loosen all other mounting bolts connect-   ing the actuator to the mounting bracket,   and set aside.   (c) Remove the actuator from the valve   shaft.   VALVE STEM   COUPLER   ANTI-ROTATION   BRACKET   2 (d) Move the actuator shaft coupling to the   opposite side of the actuator, as displayed   in Figure 7.   MOUNTING   PLATE   1 WING NUT   1 STEM RETAINER PLATE   VALVE BODY   1 2 INCLUDED IN REPLACEMENT KIT (PART NO. 5112-11).   THIS PART USED WITH NON-SPRING RETURN ACTUATORS.   M27714   M29526   Fig. 7. SCSA Mounting   For detailed actuator information, see Honeywell forms:   — 63-2209 ML6161,ML7161 Product Data Sheet.   — 63-2607 S05,S10,S20 Series Actuator Product Data   Sheet.   Fig. 6. Valve assembly exploded view.   3 62-0197—04   VBN2, VBN3 CONTROL BALL VALVE/ACTUATOR ASSEMBLIES   F B E D A C PIPE SIZE   Cv   DIMENSIONS IN INCHES (mm)   WEIGHT REPLACEMENT   STEM   IN. (DN) CODE DESIGNATORS   1/2 15 VBN2A... B,D,E,F,G,H,K   A B C D E F 2 LB (KG) ASSEMBLY   2-3/8 (60)   2-3/4 (70) 6-5/8 (168)   8-1/8 (206)   J 2-5/8 (67)   2-7/8 (73) 6-1/2 (165)   8-5/16 (211)   5112-19   1.0 (0.5)   3/4 20 VBN2B... B,D,E,G,H,J,L   1 2-3/4 (70) 6-7/16 (163)   2-7/8 (73) 6-1/2 (165)   8-1/8 (206)   8-5/16 (211)   5112-22 (SS)   K,M   1 1 25 VBN2C... J   HLP   M,N   2-3/4 (70)   3-1/16 (78) 3-1/16 (78) 6-3/4 (171)   4-5/16 (109) 3-1/4 (82) 7-3/8 (187)   7-1/16 (179)   1 8-11/16 (221) 1.4 (0.6)   8-7/8 (225)   2.4 (1.1)   8-11/16 (221) 1.4 (0.6)   1 5112-20   1 3 (76)   3-5/8 (92)   3-1/8 (79) 6-11/16 (170)   3-1/4 (82) 7 (178)   3 4   (76) (102)   5112-23 (SS)   1-1/4 30 VBN2D... H,J,K,L,N   M,S   9-1/16 (230)   2.4 (1.1)   1 1 1-1/2 40 VBN2E... L,M,R   3-7/16 (87)   6-15/16 (176)   N,1   1 1 4-1/16 (103) 3-3/4 (95) 7-1/16 (180)   8-7/8 (225)   3.2 (1.5)   2 50 VBN2F... N,T   4 (102)   7-3/16 (183)   7-7/16 (189)   5112-21   P,R,S,1,2   4-15/16 (125) 4-1/16   10-1/2 (267)   10-11/16 (271)   1 5112-24 (SS)   (103)   2-1/2 65 VBN2G... N,P,R,S,U,1   80 VBN2H... N,P,R,T,U   5-5/16 (135)   7-9/16 (192)   7-11/16 (195)   1 3 5-3/4 (146)   1 INDICATES FULL PORT VALVE: NO FLOW CHARACTERIZING INSERT.   WILL BE SHORTER WITH NON-SPRING-RETURN ACTUATORS.   1 2 M31359   Fig. 8. VB2 dimensions in inches (mm).   F B G E D A C PIPE SIZE   Cv   WEIGHT REPLACEMENT   DIMENSIONS IN INCHES (mm)   STEM ASSEMBLY   IN. (DN) CODE DESIGNATORS   1/2 15 VBN2A... B,D,E,F,H,J   C,D,E,F,G,K   A B C D E F G LB (KG)   2.4 (1.1) 5112-19   2.0 (0.9)   3-1/2 (89)   7 (178)   9-3/8 (238) 2 (51)   2-13/16 (71)   3-13/16 (97)   3 (76)   3/4 20 VBN2B...   1 3-5/16 (84) 6-1/2 (165)   7-5/16 (186)   8-13/16 (224)   1 25 VBN2C...   9-1/2 (241) 2-1/16 (52) 2.8 (1.3)   9-13/16 (249) 2-7/16 (62) 2.6 (1.2)   C,D,E,F,G   5112-20   5112-21   3-13/16 (97) 6-13/16 (173)   J,L   4-5/16 (110) 4 (102)   7-13/16 (198)   10-13/16 (275) 3-1/8 (79) 3.3 (1.5)   H,K,M   1 1-1/4 30 VBN2D... H,J,L   K,M,N   3 (76) 3-13/16 (97) 6-13/16 (173)   3 4 9-13/16 (249) 2-13/16 (71) 2.4 (1.1)   10-5/16 (262) 2-7/16 (62) 2.8 (1.3)   (76) (102)   3-5/8 (92) 4 (102)   4-5/16 (110)   4 (102)   7-5/16 (186)   1 1 1-1/2 40 VBN2E... H,J,K,M   L,P   7-13/16 (198)   10-13/16 (275) 2-3/4 (70) 3.3 (1.5)   4-1/2 (114) 7-5/16 (186)   11 (279)   3-3/16 (81)   2 50 VBN2F... L,N,P   R,T   3-1/8 (79)   5 (127)   5-13/16 (148) 7-13/16 (198)   12-5/16 (313) 3-7/8 (98) 3.8 (1.7)   4-1/8 (105)   2-1/2 65 VBN2G... P,R,S,   1 M31360   INDICATES FULL PORT VALVE: NO FLOW CHARACTERIZING INSERT.   1 Fig. 9. VB3 dimensions in inches (mm).   Automation and Control Solutions   Honeywell International Inc.   1985 Douglas Drive North   Honeywell Limited-Honeywell Limitée   35 Dynamic Drive   Golden Valley, MN 55422   Toronto, Ontario M1V 4Z9   ® U.S. Registered Trademark   © 2010 Honeywell International Inc.   62-0197—04 E.K. Rev. 04-10   Printed in U.S.A.   |