		 Installation Manual of Room Air Conditioner   
					Read this manual before installation   
					Explain sufficiently the operating means to the user   
					according to this manual.   
					Necessary Tools for Installation   
					1.Driver   
					5.Torque wrench(17mm,22mm,26mm)   
					9.Nipper   
					12.Reamer   
					2.Hacksaw   
					3.Hole core drill   
					4.Spanner(17,19 and 26mm)   
					6.Pipe cutter   
					7.Flaring tool   
					8.Knife   
					10.Gas leakage detector or   
					soap-and-water solution   
					11.Measuring tape   
					Drawing for the installation of indoor and outdoor units   
					Accessory parts   
					Number   
					of   
					No. Accessory parts   
					articles   
					Remote controller   
					1 
					1 
					2 
					1 
					Optional parts for piping   
					Mark   
					Parts name   
					2 
					R-03 dry battery   
					A 
					Non-adhesive tape   
					Adhesive tape   
					B 
					C 
					D 
					3 
					Saddle(L.S) with screws   
					Mounting plate   
					Connecting electric cable   
					for indoor and outdoor   
					Drain hose   
					1 
					E 
					F 
					4 
					Drain hose   
					Heating insulating material   
					Piping hole cover   
					4X50   
					Steel nail, cement   
					G 
					5 
					6 
					4 
					Attention must be paid to   
					the rising up of drain hose   
					A 
					6 
					4X25   
					Screw   
					Plastic cap   
					1 
					1 
					7 
					8 
					Drain-elbow   
					Cover   
					Arrangement of piping directions   
					Rear left   
					C 
					Rear   
					right   
					Left   
					Cushion   
					4 
					1 
					9 
					Right   
					Below   
					10   
					11   
					Pipe supporting plate   
					Connecting cable   
					1 
					D 
					Note:Cooling only units don't have Drain-elbow   
					E 
					A 
					G 
					The marks from to in the figure are the parts numbers.   
					The distance between the indoor unit and the floor should be   
					more than 2m.   
					No.0010518787   
				500   
					140   
					113.5   
					113.5   
					140   
					583   
					140   
					415   
					140   
					Floor fixing dimensions   
					of the outdoor unit   
					(Unit:mm)   
					Floor fixing dimensions   
					of the outdoor unit   
					(Unit:mm)   
					Floor fixing dimensions   
					of the outdoor unit   
					(Unit:mm)   
					HSU-24LEK13   
					HSU-18LEK03/(DB)   
					HSU-09LEK03/(DB)   
					HSU-12LEK03/(DB)   
					HSU-18LEK13   
					HSU-108CH09   
					HSU-138CH09   
					HSU-12LEK13-M   
					HSU-09LEK13   
					HSU-12LEK13   
					HSU-07LEK03   
					HSU-07HEK03   
					HSU-09LEK03   
					HSU-12LEK03   
					HSU-09HEK03   
					HSU-12HEK03   
					HSU-18HEK03   
					HSU-24HEK03   
					Selection of pipe   
					For 07 09 108   
					For 12 18 138   
					6.35mm(1/4")   
					12.7mm(1/2")   
					For 24   
					To this unit, both liquid and gas pipes shall be insulated   
					as they become Iow temperature in operation.   
					Use optional parts for piping set or pipes covered with   
					equivalent insulation material.   
					9.52mm(3/8")   
					15.88mm(5/8")   
					Liquid pipe (   
					Gas pipe   
					) 
					6.35mm(1/4")   
					9.52mm(3/8")   
					( 
					) 
					Indoor unit   
					1.Fitting of the Mounting Plate and Positioning of the wall Hole   
					When the mounting plate is first fixed   
					1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be   
					fixed against the wall, then temporarily fasten the plate with one steel nail.   
					2. Make sure once more the proper level of the plate, by hanging a thread with a weight from   
					the central top of the plate, then fasten securely the plate with the attachment steel nail.   
					3. Find the wall hole location A using a measuring tape   
					B= 60mm   
					B= 60mm   
					HSU-24HEK03   
					HSU-24LEK13   
					A=145mm   
					B= 60mm   
					HSU-12LEK13-M   
					HSU-09LEK13   
					HSU-12LEK13   
					HSU-07LEK03   
					HSU-07HEK03   
					A=145mm   
					HSU-09LEK03   
					HSU-12LEK03   
					HSU-09HEK03   
					HSU-12HEK03   
					HSU-108CH09   
					HSU-138CH09   
					HSU-18HEK03   
					HSU-18LEK13   
					HSU-18LEK03/(DB)   
					HSU-09LEK03/(DB)   
					HSU-12LEK03/(DB)   
					A=145mm   
					2.Making a Hole on the Wall and Fitting the Piping Hole Cover   
					Indoor side   
					Wall hole   
					60mm   
					Outdoor side   
					Make a hole of 60 mm in diameter,   
					slightly descending to outside the wall.   
					Install piping hole cover and seal it   
					off with putty after installation   
					Thickness   
					of wall   
					G 
					Piping hole pipe   
					(Section of wall hole)   
					2 
				Indoor unit   
					Connecting the indoor/outdoor Electric Cable   
					Removing the wiring cover   
					Remove terminal cover at right bottom corner of indoor unit, then   
					take off wiring cover by removing its screws.   
					When connecting the cable after installing the indoor unit   
					1. Insert from outside the room cable into left side of the wall hole, in which   
					the pipe has already existed.   
					2. Pull out the cable on the front side, and connect the cable making a loop.   
					When connecting the cable before installing the indoor unit   
					Insert the cable from the back side of the unit, then pull it out on the front side.   
					Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws.   
					Pull the cable slightly to make sure the cables have been properly inserted and tightened.   
					After the cable connection, never fail to fasten the connected cable with the wiring cover.   
					Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wi   
					is not correct, proper operation can not be carried out and will cause defect.   
					ring   
					1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar   
					qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW).   
					2. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.   
					If the fuse of outdoor unit on PC board is broken, please change it with the type of T. 25A/250V.   
					3. The wiring method should be in line with the local wiring standard.   
					4. After installation, the power plug should be easily reached.   
					5. A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the   
					distance between its two contacts should be not less than 3mm.   
					Power cable:   
					3G1.0mm   
					Power cable:   
					5G1.0mm   
					3G1.0mm   
					3G1.0mm   
					Indoor unit   
					HSU-12HE K03   
					Outdoor unit   
					HSU-07HE K03   
					Indoor unit   
					Indoor unit   
					Outdoor unit   
					Outdoor unit   
					HSU-09HE K03   
					HSU-18HEK03   
					HSU-12LEK13-M   
					HSU-108CH09   
					HSU-138CH09   
					HSU-09LEK03   
					HSU-12LEK03   
					/ 
					(DB)   
					/(DB)   
					Power cable:   
					3G1.5mm   
					connecting wiring:   
					3G1.5mm +1X0.75mm   
					Power cable:   
					3G2.5mm   
					3G2.0mm   
					Power cable:   
					3G1.0mm   
					4G0.75mm   
					HSU-18LEK13   
					Indoor unit   
					Outdoor unit   
					Indoor unit   
					HSU-24LEK13   
					Power cable:   
					3G1.5mm   
					Power cable:   
					3G2.5mm   
					Outdoor unit   
					4G0.75mm2   
					6G0.75mm   
					Indoor unit   
					Indoor unit   
					Indoor unit   
					Outdoor unit   
					POWER   
					HSU-24HEK03   
					Outdoor unit   
					HSU-09LEK13   
					{ 
					HSU-09LEK03   
					HSU-12LEK03   
					HSU-12LEK13   
					HSU-07LEK03   
					connecting wiring:   
					HSU-18LEK03/(DB)   
					BR   
					BL   
					POWER   
					SUPPLY   
					Outdoor unit   
					Y/G   
					-mod 07-12: 3G1.0mm   
					Power cable:   
					-mod 07-12: 3G1.0mm   
					3 
				Outdoor unit   
					Outdoor unit   
					1.Connection of pipes   
					To bend a pipe, give the roundness as large as possible not to crush the pipe   
					Connecting the pipe of gas side first makes working easier.   
					The max vertical distance between the indoor unit and the outdoor unit is 5 m.   
					Forced fastening without careful centering   
					may damage the threads and cause a   
					leakage of gas.   
					Half union   
					Flare nut   
					Fastening torque   
					Pipe Diameter (   
					) 
					Spanner   
					Liquid side 6.35mm(1/4")   
					Liquid side 9.52mm(3/8")   
					18N.m   
					40N.m   
					Torque wrench   
					Gas side 9.52mm(3/8")   
					Gas side 12.7mm(1/2")   
					40N.m   
					50N.m   
					Be careful that matters, such as wastes of sands, etc.   
					shall not enter the pipe.   
					Gas side 15.88mm(5/8")   
					60N.m   
					2.Attaching Drain-Elbow   
					If the drain-elbow is used, please attach it as   
					figure. (Note: Only for heat pump unit.)   
					3.Purging Method:   
					Push the air out of the indoor unit and piping as followes:   
					Tighten the caps on the valves with specified torque.   
					Tighten torque N.m   
					7-9   
					Valve rod   
					Valve cap   
					20-25   
					When connecting pipe exceeds 5 meters, 20g or 60g(only for 22k 24k) refrigerant shall be   
					added per exceeding meter. Charge according to the following list.   
					for 22k 24k   
					for 5k 7k 9k 10k 12k 13k 18k   
					10m   
					Piping length   
					Piping length   
					5m   
					7m   
					5m   
					7m   
					10m   
					20m   
					Additional amount No need   
					40g   
					100g   
					300g   
					Additional amount   
					120g   
					No need   
					900g   
					Outdoor unit   
					Indoor unit   
					A 
					A 
					A 
					Outdoor unit   
					Oil trap   
					Indoor unit   
					B 
					C 
					Outdoor unit   
					B 
					Indoor unit   
					B 
					for 5K 7K 9K 10K 12K 13K: B=5m   
					for 18K 22K 24K: B=10m   
					Max.Elevation:   
					Max. Length:   
					CAUTION   
					C 
					In case more than 5 metres,oil trap   
					for 5K 7K 9K 10K: A=7m   
					should be installed every 5~7m.   
					for 12K 13K:   
					A=10m   
					for 18K 22K 24K: A=20m   
					4 
				 |