Haier Air Conditioner HSU 12HKAGR2DB User Manual

SPLIT TYPE ROOM AIR CONDITIONER  
OPERATION MANUAL  
Contents  
1
PARTS AND FUNCTIONS  
OPERATION  
2
5
6
7
MAINTENANCE  
CAUTIONS  
TROUBLE SHOOTING  
HSU-09LEK03/R2(DB)  
HSU-12LEK03/R2(DB)  
HSU-09LEK13/R2(DB)  
HSU-12LEK13/R2(DB)  
HSU-18LEK13/R2(DB)  
HSU-24LEK13/R2(DB)  
HSU-12CKAS(R2DB)  
HSU-18CKAS(R2DB)  
HSU-12HKAG(R2DB)  
HSU-18HKAG(R2DB)  
Ɣ
Please read this operation manual before using the air conditioner.  
Keep this operation manual for future reference.  
0010562830  
Parts and Functions  
Remote controller  
Indoor Unit  
Remote controller A  
Inlet  
Air Purifying Filter  
(inside)  
1
8.Additional functions display  
6
Operation mode QUIET SLEEP HEALTH TURBO  
Remote controller  
2
7
9. TURBO button  
10. FAN button  
11. COOL button  
12. AUTO button  
13. FAN SPEED button  
14. TIMER button  
15. SLEEP button  
16. LOCK button  
Used to lock buttons and LCD display.  
17. LIGHT button  
Control the lightening and extinguishing  
of the indoor LED display board.  
18. POWER ON/OFF button  
19. DRY button  
20. TEMP button  
Inlet grille  
Outlet  
3
4
5
9
8
18  
Vertical blade  
(adjust left and  
10  
11  
Emergency  
Switch  
19  
20  
Horizontal flap  
(adjust up and down air flow  
Don't adjust it manually)  
ight air flow)  
r
Display board  
12  
13  
4
21  
22  
1
2
5
3
Display board  
14  
15  
21. SWING button  
22. HOUR button  
23  
24  
TIMER ON\OFF display  
TIMER ON-OFF display  
SLEEP display  
4
1
2
Signal receiver hole  
ON/OFF display  
23. EXTRA FUNCTION button  
16  
17  
3 Ambient temp.display  
25  
Note to the power failure resume:  
press the sleep button ten times in five seconds  
and enter function after hearing four sounds.And  
press the sleep button ten times within five  
seconds and leave this function after hearing  
two sounds.  
Function: Health--- Healthy airflow  
position1--- Healthy airflow position 2  
--- Restore the original flap position---  
Right & left air airflow--- A-B yard---  
Refresh air(reserved function)--- QUIET  
--- Fahrenheit/Celsius mode conversion  
When receiving the remote  
control signal, display the set  
temperature and in the rest  
time the room temperature is  
displayed.  
1. Mode display  
Operation mode AUTO COOL DRY  
FAN  
Remote controller  
5
COOL\HEAT\Dry\AUTO display  
2. Signal sending display  
3. SWING display  
4. FAN SPEED display  
Display  
24.CANCEL/CONFIRM button  
Function: Setting and cancel to the  
timer and other additional functions.  
25. RESET button  
Inlet  
Air Purifying Filter  
4  
1
circulated  
AUTO  
(inside)  
LO  
MED  
HI  
When the remote controller  
appears abnormal, use a sharp  
pointed article to press this button  
to reset the remote  
5. LOCK display  
6.TIMER OFF display  
TIMER ON display  
7.TEMP display  
8
Inlet grille  
Outlet  
2
Emergency  
Switch  
Remote controller B  
1
8.Additional functions display  
6
7
9
10  
11  
3
Supplemented  
electrical  
heating  
Operation mode QUIET SLEEP  
HEALTH TURBO  
Anion generator  
(inside)  
5  
7
Vertical blade  
(adjust left and  
2
12  
6
Remote controller  
9. TURBO button  
10. HEAT button  
11. COOL button  
12. AUTO button  
13. FAN SPEED button  
14. TIMER button  
15. SLEEP button  
16. LOCK button  
Used to lock buttons and LCD display.  
17. LIGHT button  
Control the lightening and extinguishing  
of the indoor LED display board.  
18. POWER ON/OFF button  
19. DRY button  
13  
3
4
5
9
Horizontal flap  
(adjust up and down air flow  
Don't adjust it manually)  
ight air flow)  
r
8
9
(Lights up when unit starts.)  
Power indicator  
18  
10  
Timer mode indicator  
(Lights up whenTimer operation is selected.)  
10  
11  
HEAT  
19  
20  
11  
12  
Operation mode indicator  
(lights up when the compressor is on.)  
12  
13  
Remote signal receiver  
21  
22  
(A beeping sound is generated when a signal  
from remote controller isreceived.)  
20. TEMP button  
21. SWING button  
22. HOUR button  
23. EXTRA FUNCTION button  
Ambient temp display  
14  
15  
13  
23  
24  
When receiving the remote control signal, display the set  
temperature and in the rest time the room temperature is  
displayed and this room temperature is only for reference.  
16  
17  
Function:  
Health--- FAN---  
25  
Healthy airflow position1---  
--- Healthy airflow position 2---  
Right & left air airflow--- A-B yard---  
Actual inlet grille may vary from the one shown in the  
manual according to the product purchased  
1. Mode display  
Operation mode AUTO COOL DRY HEAT FAN  
Remote controller  
Low-Temperature Heating Operation Down to 10  
Outdoor Unit  
--- Refresh air( )-- QUIET  
reserved function  
2. Signal sending display  
3. SWING display  
4. FAN SPEED display  
--- Fahrenheit/Celsius mode conversion  
24.CANCEL/CONFIRM button  
Function: Setting and cancel to the  
timer and other additional functions.  
Display  
circulated  
OUTLET  
AUTO  
LO  
MED  
HI  
25. RESET button  
INLET  
When the remote controller  
appears abnormal, use a sharp  
pointed article to press this button  
to reset the remote  
5. LOCK display  
CONNECTING PIPING  
6.TIMER OFF display  
TIMER ON display  
7.TEMP display  
AND ELECTRICAL WIRING  
4
DRAIN HOSE  
4
NOTE: Healthy function is not available for some units.  
1
Operation  
Air Flow Direction Adjustment  
Unit start / stop  
1.Status display of air flow  
Press  
cycle display to  
enter to up and down air flow function.  
button to enter additional options, when  
,
will flash. And then press  
Remote controller  
1
3
2
Press  
button. For each press,changes as follows:  
2
Remote controller:  
COOL/DRY:  
HEAT:  
Initial state  
2.Left and right air flow adjustment  
(This function is unavailable on some models.)  
Press  
cycle display to  
enter to Left and right air flow function.  
button to enter additional options, when  
1. Unit start  
Press ON/OFF on the remote controller, unit starts.  
,
will flash. And then press  
2.Select temp.setting  
button  
Press  
/
Press  
button. For each press,changes as follows:  
Every time the button is pressed, temp.setting  
increase 1oC,if kept depressed, it will increase  
rapidly  
Remote controller:  
COOL/DRY/HEAT:  
Every time the button is pressed, temp.setting  
decrease 1oC,if kept depressed, it will  
decrease rapidly  
Cautions:  
Select a desired temperature.  
When adjusting the flap by hand,turn off the unit.  
When humidity is high,condensate water might occur  
at air outlet if all vertical louvers are adjusted to left or  
right.  
3.Fan function  
Remote controller A:  
Press FAN button.  
Remote controller B:  
It is advisable not to keep horizontal flap at downward  
Press  
button to enter additional options, when  
mode ,  
position for a long time in COOLor DRY  
cycle display to  
,
will flash. And then press  
button fan speed  
otherwise, condensate water might occur.  
Note:  
When restart after remote turning off, the remote  
controller will automatically return to the previous  
set swing position.  
enter to FAN function.  
For each press  
changes as follows:  
Remote controller:  
Loading of the battery  
Display  
circulated  
MED  
HI  
Remove the battery cover;  
LOW  
AUTO  
1
Load the batteries as illustrated.  
2 R-03 batteries, resetting key  
2
Air conditioner is running under displayed fan speed.  
When FAN is set to AUTO, the air conditioner  
automatically adjusts the fan speed according to room  
temperature.  
3 (cylinder);  
Be sure that the loading  
is in line with the" + "/"-";  
Remote  
Operation  
Mode  
Load the battery,then put on the cover again.  
4
Display Board  
Note  
Controller  
Note:  
Under the mode of auto operation, air conditioner will  
automatically select Cool or Heat operation according  
to room temperature. When FAN is set to AUTO, the  
air conditioner automatically adjusts the fan speed  
according to room temperature.  
The distance between the signal transmission head and the rece-  
iver hole should be within 7m without any obstacle as well.  
When electronic-started type fluorescent lamp or change-over  
type fluorescent lamp or wireless telephone is installed in the  
room, the receiver is apt to be disturbed in receiving the signals,  
so the distance to the indoor unit should be shorter.  
AUTO  
COOL  
Cooling only unit do not have displays and functions  
related with heating  
In DRY mode, when room temperature becomes  
lower than temp.setting+2oC,unit will run intermittently  
at LOW speed regardless of FAN setting.  
DRY  
Full display or unclear display during operation indicates the  
batteries have been used up.  
Please change batteries.  
If the remote controller can't run normally during operation, please  
In HEAT mode,warm air will blow out after a short  
periodof the time due to cold-draft prevention function.  
HEAT  
reload several minutes later.  
remove the batteries and  
In FAN operation mode, the unit will not operate in  
COOL or HEAT mode but only in FAN mode ,AUTO is  
not available in FAN mode.And temp.setting is disabled.  
When FAN is set to AUTO, the air conditioner automatically  
adjusts the fan speed according to room temperature.  
In FAN mode,SLEEP operation is not available.  
Hint:  
FAN  
nothing  
Remove the batteries in case won't be in use for a long period. If  
there is any display after taking-out, just press reset key.  
2
Operation  
Timer On/Off On-Off Operation  
TURBO/QUIET Operation  
(This function is unavailable on some models.)  
1.After unit starts, select your desired operation mode.  
2.Press TIMER button to change TIMER mode. Every  
time the button is pressed, display changes as follows:  
(1)  
TURBO Operation  
When you need rapid heating or cooling, you can use this function.  
Press TURBO button, the remote controller will show  
and then achieve to the turbo function. Press again this  
TURBO button , the turbo function will be cancelled.  
,
Remote controller:  
BLANK  
0.5h  
0.5h  
0.5h  
TIMER ON-OFF  
0.5h  
TIMER OFF-ON  
TIMER ON TIMER OFF  
(2)  
QUIET Operation  
Press button to enter additional options, when cycle  
display to will flashand then press ,enter to  
Then select your desired TIMER mode (TIMER ON or  
TIMER OFF or TIMER ON-OFF). " "or " "will flash.  
3.Press button to set time.  
,
quiet function. When cancel the function, please enter  
additional options again and to cancel quiet function.  
/
Press the button for each time, setting time in the first  
12 hours increased by 0.5 hour every time, after 12  
hours,increased by 1 hour every time.  
Note  
the room  
During TURBO operation, in rapid COOL mode ,  
will show inhomogeneous temperature distribution.  
Long period QUIET operation will cause effect of not too  
cool or not too warm.  
Press the button for each time, settiing time in the first  
12 hours decreased by 0.5 hour every time, after 12  
hours,decreased by 1 hour every time.  
It can be adjusted within 24 hours.  
4.Confirm timer setting  
Emergency operation and test operation  
After adjust the time,press  
button and confirm the  
Pi  
time ON or OFF button will not flash any more.  
5.Cancel timer setting  
Emergency Operation:  
Use this operation only when the remote controller  
is defective or lost.  
When the emergency operation switch is  
pressed,the" Pi "sound is heard once, which means  
the start of this operation.  
Press the timer button by times until the time display  
eliminated.  
In this operation, the system automatically selects  
the operation modes,cooling or fan or heat,according  
to the room temperature.  
Hints:  
Room  
temperature  
Timer  
mode  
Operation Designated  
Air flow  
mode  
temperature  
After replacing batteries or a power failure happens, time  
setting should be reset.  
ABOVE 23OC COOLING  
26OC  
AUTOMATIC  
AUTOMATIC  
NO  
NO  
BELOW 23OC  
HEAT  
23OC  
According to the Time setting sequence of TIMER ON or  
(Cooling only uint  
Room temperature  
Timer  
mode  
Operation Designated  
Air flow  
mode  
temperature  
TIMER OFF, either Start-Stop or Stop-Start can be achieved.  
BELOW 23OC  
FAN  
26OC  
AUTOMATIC  
NO  
It is not possible to operate in dry mode.  
HEALTH Operation  
(This function is unavailable on some models.)  
Test operation:  
Test operation switch is the same as emergency switch.  
Use this switch in the test operation when the room  
temperature is below 16oC, do not use it in the  
Press  
button to enter additional options, when cycle  
will flashand then press ,enter to  
display to  
,
health function. When cancel the function, please enter  
additional options again and to cancel health function.  
Pi Pi  
normal operation.  
Continue to press the test operation  
switch for more than 5 seconds. After  
The anion generator in the airconditioner can generate  
a lot of anion effectively balance the quantity of position  
and anion in the air and also to kill bacteria and speed  
up the dust sediment in the room and finally clean the  
air in the room.  
you hear the "Pi" sound twice,release  
your finger from the switch: the cooling  
operation starts with the air flow speed "Hi".  
After 30 minutes, test operation ends automatically(Only for 22K,24K unit).  
3
Operation  
Comfortable SLEEP  
SLEEP  
5. When quiet sleeping function is set to 8 hours the quiet  
sleeping time can not be adjusted.When TIMER function is  
set,the quiet sleeping function can't be set up.After the  
sleeping function is set up,if user resets TIMER function, the  
sleeping function will be cancelled; the machine will be in the  
state of timing-on,if the two modes are set up at the same  
time,either of their operation time is ended first,the unit will  
stop automatically,and the other mode will be cancelled.  
Press  
show  
button , the remote controller will  
, and then achieve to the sleep function.  
SLEEP  
Press again this  
be cancelled.  
button , the sleep function will  
Note  
When TIMER function is set, the sleeping function can’t be  
set up .After the sleeping function is set up,if user resets  
TIMER function, the sleeping function will be cancelled; the  
machine will be in the state of timing-on.  
Operation Mode  
1. In COOL,DRY mode  
1 hours after SLEEP mode starts,temp.will become  
1OC higher than temp.setting.After another 1 hours,  
temp.risesby 1OC futher .The unit will run for further  
6 hours then stops Temp. is higher than temp.setting  
so that room temperature won’t be too low for your  
sleep.  
Note to the power failure resume:  
press the sleep button ten times in five seconds and enter  
function after hearing four sounds.And press the sleep button  
ten times within five seconds and leave this function after  
hearing two sounds.  
Power Failure Resume Function  
SLEEP operation starts  
SLEEP operation stops  
Approx.6hrs  
If the unit is started for the first time, the compressor will not  
start running unless 3 minutes have elapsed. When the power  
resumes after power failure, the unit will run automatically,  
and 3 minutes later the compressor starts running.  
Rises 1OC  
Rises 1OC  
1 hr  
1 hr  
Healthy airflow Operation  
Temp.setting  
1.Press  
to starting  
Unit stop  
In COOL, DRY mode  
Setting the comfort work conditions.  
2.The setting of healthy airflow function  
2.In HEAT mode  
Press  
button to enter additional options,Press this  
1 hours after SLEEP mode starts, temp will become  
button continuously, the louvers location will cycle between  
in the following three locations, to choose the swing location  
2OC lower than temp.setting. After another 1 hours,  
temp decrease by 2 OC further. After more another  
3 hours, temp.risesby 1 OC further.The unit will run  
for further 3 hours then stops.Temp. is lower than  
temp. setting so that room temperature won't be too  
high foryour sleep.  
what you needed,and then press  
button to confirm.  
Healthy  
airflow  
upwarder  
Healthy  
airflow  
downwarder  
Present  
position  
3.The cancel of the healthy airflow function  
Press  
button to enter additional options,Press this  
Unit stop  
Temp.setting  
1 hr  
button continuously, the louvers location will cycle between  
in the following three locations again,and then press  
button to cancel.  
O
C
Decreases 2  
1 hr  
O
C
Decreases 2  
Notice: Do not direct the flap by hand. Otherwise, the  
3 hrs  
grille will run incorrectly. If the grille is not run correctly, stop  
Rises 1OC  
3 hrs  
for a minute and then start, adjusting by remote  
controller.  
SLEEP  
SLEEP  
operation starts  
operation stops  
In HEAT mode  
Note:  
3.In AUTO mode  
1.After setting the healthy airflow function, the position  
grill is fixed.  
The unit operates in corresponding sleep mode  
corresponding sleep mode adapted to the  
automatically selected operation mode.  
2.In cooling, it is better to select the  
mode.  
3.In cooling and dry, using the air conditioner for a long  
time under the high air humidity, condensate water may  
occur at the grille .  
4. In FAN mode  
It has no SLEEP function.  
4
Cautions  
WARNING  
Please call Sales/Service Shop for the Installation.  
Do not attempt to install the air conditioner by yourself because improper works  
may cause electric shock, fire, water leakage.  
WARNING  
When abnormality such as burnt-small found,  
immediately stop the operation button and  
contact sales shop.  
Check proper installation of the  
drainage securely  
Use an exclusive  
power source  
with a circuit  
breaker  
STRICT  
ENFORCEMENT  
STRICT  
OFF  
ENFORCEMENT  
1.Do not use power supply cord extended  
or connected in halfway  
Connect power supply cord  
to the outlet completely  
Use the proper voltage  
2.Do not install in the place where there is any  
possibility of inflammable gas leakage around the unit.  
3.Do not get the unit exposed  
to vapor or oil steam.  
STRICT  
STRICT  
ENFORCEMENT  
ENFORCEMENT  
PROHIBITION  
Take care not to damage  
Do not use power supply  
Do not insert objects into the air  
inlet or outlet.  
the power supply cord.  
cord in a bundle.  
PROHIBITION  
PROHIBITION  
PROHIBITION  
Do not channel the air flow directly  
at people, especially at infants or  
the aged.  
Do not start or stop the  
operation by disconnecting  
the power supply cord  
and so on.  
Do not try to repair or  
reconstruct by yourself.  
Connect the earth  
cable.  
earthing  
PROHIBITION  
PROHIBITION  
CAUTION  
Take fresh air occasionally especially  
when gas appliance is running at the  
same time.  
Do not operate the switch with  
wet hand.  
Do not use for the purpose of storage of  
food, art work, precise equipment,  
breeding, or cultivation.  
STRICT  
ENFORCEMENT  
PROHIBITION  
PROHIBITION  
Do not pour water onto the unit for  
Do not install the unit near a fireplace  
or other heating apparatus.  
Check good condition of the installation  
stand  
cleaning  
PROHIBITION  
PROHIBITION  
PROHIBITION  
Do not place flower vase or water  
containers on the top of the unit.  
Do not place any objects on or  
climb on the unit.  
Do not place animals or plants in  
the direct path of the air flow  
PROHIBITION  
PROHIBITION  
PROHIBITION  
6
Trouble shooting  
Cautions  
The machine is adaptive in following situation  
1.Applicable ambient temperature range:  
Before asking for service, check the following  
first.  
Phenomenon  
Cause or check points  
oC/23oC  
C/14  
For: T1  
Maximum: D.B / W.B 32  
When unit is stopped, it won't restart  
immediately until 3 minutes have  
elapsed to protect the system.  
When the electric plug is pulled out  
and reinserted, the protection circuit  
will work for 3 minutes to protect the  
air conditioner.  
The system does not restart  
immediately.  
Indoor  
oC  
o
Minimum: D.B / W.B 18  
Cooling  
o
Maximum: D.B  
Minimum: D.B  
oC  
43 C/26  
18oC  
Outdoor  
During unit operation or at stop,  
a swishing or gurgling noise may  
For: T3  
29o C/19 o C  
Maximum: D.B / W.B  
Indoor  
be heard.At first 2-3 minutes after  
unit start, this noise is more noticeable.  
(This noise is generated by  
Minimum: D.B / W.B 18o C/14 o C  
Maximum: D.B / W.B 54o C/24 o C  
Noise is heard  
Cooling  
refrigerant flowing in the system.)  
During unit operation, a cracking  
noise may be heard.This noise is  
generated by the casing expanding  
or shrinking because of  
Outdoor  
18o C  
Minimum: D.B  
Normal  
Performance  
inspection  
temperature changes.  
2. If the supply cord is damaged, it must be replaced by the  
manufacturer or its service agent or a similar qualified person.  
The type of connecting wire is H05RN-F or H07RN-F  
3. If the fuse on PC board is broken please change it with a fuse  
type T. 3.15A/250V.  
Should there be a big noise from  
air flow in unit operation, air  
filter may be too dirty.  
This is because the system  
circulates smells from the interior  
air such as the smell of furniture,  
paint, cigarettes.  
Smells are generated.  
Mist or steam are blown out.  
During COOL or DRY operation,  
indoor unit may blow out mist.  
This is due to the sudden cooling  
of indoor air.  
If the fuse of outdoor unit on PC board is broken, please change  
it with the type of T. 25A/250V.  
In DRY mode, when room  
temperature becomeslower  
than temp.setting+2oC,unit will  
run intermittently at LOW speed  
regardless of FAN setting.  
4.The distance between the indoor unit and the floor should be  
more than 2m.  
fan  
In dry mode,  
speed can’t be changed.  
5.The wiring method should be in line with the local wiring standard.  
6. After installation, the power plug should be easily reached.  
7.The used batteries should be disposed of properly.  
8.The appliance is not intended to use by young children or infirm  
persons without supervision.  
Is power plug inserted?  
Is there a power failure?  
Is fuse blownout?  
Is the air filter dirty?  
Normally it should be cleaned  
every 15 days.  
Poor cooling  
Multiple  
check  
Are there any obstacles before  
inlet and outlet?  
9.Young children should be supervised ensure that they do not  
play with the appliance.  
Is temperature set correctly?  
Are there some doors or  
windows left open?  
Is there any direct sunlight  
10.The appliance must be installed on a strong enough support.  
11.The wiring diagram is attached inside the machine.  
through the window during the  
cooling operation?(Use curtain)  
Are there too much heat sources  
or too many people in the room  
during cooling operation?  
T1: Application temp. range of air conditioner -7oC~43oC.  
T3: Application temp. range of air conditioner -7oC~54oC.  
7

Admiral AAW 06CR1FHUE User Manual
Briggs Stratton Automobile Parts 400000 User Manual
Bush Hog M246 User Manual
Carrier 30HR User Manual
Friedrich ZQ08A10C User Manual
Holmes Air Conditioner HLH4422EE User Manual
Honda Automobiles Tonneau Cover 4D16070S User Manual
Honeywell M7415 User Manual
HP Hewlett Packard LaserJet M9050 MFP User Manual
HP Hewlett Packard OfficeJet LX User Manual