| CABINET TYPE AIR CONDITIONER   Operation & Installation Manual   HPU-42CH03   HPU-48CJ03   HPU-48HJ03   HPU-42HH03   HPU-42HI03   HPU-48HK03   HPU-48CK03   No.0150509772   B Please read this operation manual before using the air conditioner.   Please keep this manual carefully and safely.   Cautions   All these valuable materials may be taken   to a waste collecting center and used again   after adequate recycling.   Disposal of the old air conditioner   Before disposing an old air conditioner   that goes out of use, please make sure   it's inoperative and safe. Unplug the air   conditioner in order to avoid the risk of   child entrapment.   Consult your local authorities for the name   and address of the waste materials   collecting centers and waste paper   disposal services nearest to your house.   It must be noticed that air conditioner   system contains refrigerants, which   require specialized waste disposal. The   valuable materials contained in a air   conditioner can be recycled. Contact   your local waste disposal center for   proper disposal of an old air conditioner   and contact your local authority or your   dealer if you have any question. Please   ensure that the pipework of your air   conditioner does not get damaged prior   to being picked up by the relevant   waste disposal center, and contribute   to environmental awareness by   insisting on an appropriate, anti-   pollution method of disposal.   Safety Instructions and Warnings   Before starting the air conditioner, read   the information given in the User's Guide   carefully. The User's Guide contains very   important observations relating to the   assembly, operation and maintenance of   the air conditioner.   The manufacturer does not accept   responsibility for any damages that may   arise due to non-observation of the   following instruction.   Damaged air conditioners are not to   be put into operation. In case of doubt,   consult your supplier.   Disposal of the packaging of your   new air conditioner   Use of the air conditioner is to be   carried out in strict compliance with the   relative instructions set forth in the User's   Guide.   All the packaging materials employed   in the package of your new air   conditioner may be disposed without   any danger to the environment.   Installation shall be done by professional   people, don't install unit by yourself.   The cardboard box may be broken or   cut into smaller pieces and given to a   waste paper disposal service. The   wrapping bag made of polyethylene   and the polyethylene foam pads   contain no fluorochloric hydrocarbon.   1 Cautions   For the purpose of safety, the air   conditioner must be properly grounded   in accordance with specifications.   Specifications   The refrigerating circuit is leak-proof.   The machine is adaptive in following   situation   Always remember to unplug the air   conditioner before opening inlet grill.   Never unplug your air conditioner by   pulling on the power cord. Always grip   plug firmly and pull straight out from   the outlet.   Applicable ambient temperature range:   Rated Maximum Minimum   DB C 27   WB C 19   DB C 35   WB C 24   32   23   43   26   27   --   18   14   10   6 15   --   Indoor   Cooling   Heating   outdoor   Indoor   20   14.5   7 DB C   WB C   DB C   WB C   24   18   -7   --   outdoor   All electrical repairs must be carried   out by qualified electricians.   Inadequate repairs may result in a   major source of danger for the user of   the air conditoiner.   6 Do not damage any parts of the air   conditioner that carry refrigerant by   piercing or perforating the air   conditioner's tubes with sharp or   pointed items, crushing or twisting any   tubes, or scraping the coatings off the   surfaces. If the refrigerant spurts out   and gets into eyes, it may result in   serious eye injuries.   Do not obstruct or cover the   ventilation grille of the air conditioner.   Do not put fingers or any other things   into the inlet/outlet and swing louver.   Do not allow children to play with the   air conditioner. In no case should   children be allowed to sit on the   outdoor unit.   2 Parts   1 2 ON/OFF   POWER   RUN   HEATER   TIMER   ON/OFF   POWER   RUN   HEATER   TIMER   Note:For cooling only unit,the "HEATER" light is   invalid;   ON/OFF: If pressing this button,the unit will enter   Auto Run mode according to the room temperature.   Indoor unit   3 4 1 Outlet grill   2 Operation panel   3 Inlet grill   4 Air filter [inside the unit]   Outdoor unit   1 2 Inlet grill   Remote controller   Outlet grill   B A 1 2 A U T O OFF   M D TEMP   1 ON   OFF   SWING   FAN   MODE   SLEEP   HEALTH   FRESH   CLOCK   TIMER   SET   HIGH/SO   HEAT   LOCK   FILTER   LIGHT   RESET   CODE   2 HPU-42CH03 HPU-48CJ03   HPU-42HH03 HPU-48HJ03   HPU-42HI03 HPU-48HK03   HPU-48CK03   3 Operation hints   Unit operation   Protection devices inside the unit will activate to stop unit operation, when ambient   temp. is extremely low or high.   When unit is running under high humidity in cooling or dehumidifying mode, condensate   might appear at outlet grill.   3-min delay protection   Unit will not restart until 3 min have elapsed for the protection of the unit.   Fan speed changes   When Fan speed is set at Auto in cooling mode, it will be automatically reduced as   room temp. is approaching temp. setting.   In dry mode, fan speed will change automatically.   Cold draft prevention   In heating mode, indoor fan will not run for the first 2-5 min. due to cold draft prevention.   Defrosting   When frost accumulates on heat exchanger in heating mode, unit will start defrosting   automatically.   During defrosting, both indoor and outdoor fan stop.   After defrosting, unit resumes running.   Use objectively   Heat pump works by means of absorbing outside heat to warm room air, so outdoor   temp. degree will affect unit's heating efficiency.   4 Energy saving   Keep proper room temp.   Too cold or too warm is no good   to your health, and power   consumption will be increased as   well.   Proper temp.   Air filter should be periodically cleaned   If air filter is clogged:   It will cause poor cooling and   heating efficiency, higher power   consumption and even problem   may occur. In cooling operation,   water will flow out.   Use Timer effectively   OFF   ON   AM8:00   You may use Timer mode to keep   a comfortable room temp.when   you wake up or come home from   outside.   PM   5:00   Avoid direct sunlight   and air flow   Adjust air flow   properly   5 Maintenance   Disconnect power supply   Don't touch it with wet   hand   Don't wash with hot water   or solvent to clean the unit   Don't spray any paint or insecticide   on the unit.   Don't splash water directly on indoor   unit.   This could be   very dangerous   This will cause damage or even fire accident.   Air filter cleaning   Pull it out from top as shown in Fig.   Use water or vacuum cleaner to clean it.   If it is extremely dirty, wash it with neutral   detergent or soap water.   Wash it with clean water and install it after   complete dry.   Caution:   Don't use hot water over 40 C, as this may cause damage to air filter.   Wipe air filter carefully.   6 Maintenance   Indoor and outdoor cleaning   Clean it with warm and wet cloth or with neutral detergent, then wipe it dry with   clean and soft cloth.   If air conditioner is very dirty, clean it with cloth soaked in neutral detergent,then   wipe off the detergent with clean water.   Don't use water higher than 40 C , which will cause discoloring and deformation.   Don't use insecticide or other chemical detergents.   After season maintenance   Let the unit run in Fan mode for half a day in a   fine weather to dry completely the unit inside.   Turn off the unit and pull out power plug.   There might be certain power consumption even   if unit is stopped.   Clean air filter and indoor unit, cover outdoor   unit after cleaning.   Before season maintenance   Check if there are obstacles at inlet and outlet of indoor and outdoor unit,   whick will reduce unit efficiency.   Don't fail to attach air filter after making sure it   is cleaned.   Dust will enter into unit causing damages or   faults if it is running without air filter.   To protect compressor at start, please connect external power supply to   the unit 12 hrs prior to starting. Also please keep the power supply switch   ON during the whole season.   7 Trouble shooting   Followings are not problems   During unit start and operation or at stop, a swishing or   gurgling noise may be heard. This noise is generated by   refrigerant flowing in the system.   Sound of water flowings are not   problems.   During unit operation, a cracking noise may be heard.   This noise is generated by the casing expanding or   shrinking because of temperatuer changes.   Sound of cracking is heard.   Smells are generated.   This is because the system circulates smells from the   interior air such as the smell of cigarettes or the painting   on the unit.   During operation, white fog or steam   comes out of indoor unit.   When unit is running at places like restaurant where dense   edible oil fumeis always exist, this will happen.   To prevent frost from accumulating on indoor heat   exchanger, unit will switch to fan operation for a while   then resume cooling operation.   In cooling operation, unit switches to fan   operation.   Unit will not restart after stop.   Won't start?   Though ON/OFF button is set to   ON, unit won't resume cooling,dry   or heating operation in 3 min after   it is stopped, this is because of 3-   min-delay protection circuit.   Please wait 3 minutes   No outlet air or fan speed can't be changed in   dry mode.   Unit will reduce fan speed repeatedly and automatically   if room temp. is too low in dry operation.   In heating operation, water or   steam are blown out of indoor   unit.   This occurs when frost   accumulated on the outdoor unit   is removed.   (during defrosting operation)   In heating operation, indoor fan won't stop even After unit stops, indoor fan will go on running until indoor   unit cools down.   if unit is stopped.   8 When problems occur   Before asking services, please firstly check your unit according to following.   Air conditioner won't start.   Is city power supply normal?   Is leakage current breaker   activated?   Is power supply switch   turned on?   This is very dangerous, please   disconnect power supply   immediately and contact your   dealer.   Power   failure?   Power supply   switch is not set   at ON.   Poor cooling or heating   Are there any obstacles at inlet   or outlet grill?   Are operation controlls   adjusted correctly   as specified?   Is air filter too dirty?   Proper   temp   Are horizontal louvers   at up position (in   heating mode)?   Any doors or windows left   open?   Poor cooling   If there are unexpected heat   sources in the room?   Too many people in the room?   Is there any direct sunlight   in the room?   If your unit still can't work properly after above mentioned checks, or following problems occur,   please stop it immediately and contact your dealer.   Fuses or circuit breakers often blow out.   Water comes out in cooling/dry operation.   Operation is abnormal or sound is heard.   If the fuse on PC board is broken please change it with the type of T6.3A/250VAC.   9 When problems occur   Power supply   The parameter of power cord is over 5G 2.5mm2.   The parameter of connect cord is 4G 0.75mm2 .   Air conditioner must use an exclusive line (over 30A)   When installation air conditioner in a wet place, try to use a circuit breaker against   current leakage.   For installation in other places, use circuit breaker as far as possible.   The breaker of the air conditioner should be all-pole switch ; and the distance between   its two contacts should be no less than 3 mm.   Such means for disconnection must be incorporation in the fixed wiring   10   Indoor & outdoor unit connection   Over 10cm   Over 10cm   Over 100cm   power cable length   Approx   1.5m   Approx   2m   pipe direction   Left   Rear   Right   Bottom   Over 10cm   Over 10cm   Over 15cm   For Example   Take HPU-42CH03   11   Over 60cm   Tools necessary   Tools necessary   1. Screw driver   2. Hacksaw   3. 70mm dia. hole core drill   4. Spanner (dia. 17, 27mm)   5. Spanner (14, 17, 27mm)   6. Pipe cutter   7. Flaring tool   8. Knife   9. Nipper   10. Gas leakage detector or soap   water   11. Measuring tape   12. Reamer   13. Refrigerant oil   Standard accessories   Following parts shall be field   supplied   Parts name   Adhesive tape   Pipe clip   Mark   A B Drain hose   C 12   Installation procedures   Display of whole unit   Try to bring the packed unit to the installation place.   When it is inevitable to unpack the unit, be careful not to damage the unit. Wrap it with   nylon etc.   After unpacking, be sure to put it with the front side of the unit facing up.   Delivery   Facing up   Note: When delivering, don't hold plastic   parts like inlet and outlet grill etc.   Installation of outdoor unit   Selection of installation place   over 30cm   Place strong enough to support the unit and will   not cause vibration and noise.   Place where discharged wind and noise doesn't   cause a nuisance to the neighbors.   Place where is less affected by rain or direct   sunlight and is sufficiently ventilated, or to install   a shield.   over 10cm   over 10cm   over 15cm   over 60cm   Place with enough space for smooth air flow.   Fixing of the unit   Fix outdoor unit using M10 bolt to concrete floor horizontally.   If installed on the wall or on top of a roof, bracket should be fixed securely to   resist earthquake or storms.   Use rubber pad during installation against unit vibration.   1008   580   948   180   HPU-42CH03 HPU-48CJ03   HPU-42HH03 HPU-48HJ03   HPU-42HI03 HPU-48HK03   HPU-48CK03   Installation dimension of outdoor unit (mm)   13   Installation procedures   Installation of indoor unit   Selection of installation place   Place where it is easy to route drainage pipe and outdoor piping.   Place away from heat source and with less direct sunlight.   Place where cool and warm air could be delivered evenly to every corner of the room.   Place near power supply socket. Leave enough space around the unit (refer to installation   drawings).   Fixing of the unit   Position of the wall hole   1.   Wall hole should be decided according to installtion place and piping direction. (refer   to installation drawings)   Making a wall hole   2.   Drill a hole of 70mm dia. with a little slope towards outside.   Install piping hole cover and seal it with putty after installation.   INDOOR SIDE   OUTDOOR SIDE   wall thickness   wall hole   70mm   ( Cross section of wall hole )   Fixing of indoor unit   To prevent it from fall off, please fix the unit with fall-prevention fitting at wall and   L-shaped metal at floor.   Self-tapping   screw   all-prevention fitting metal   Wood screw   Please install the whole unit   horizontally,with a slop of 1 degree at   front and rear,left and right.   L-shaped metal   14   Installation procedures   Installation of fall-prevention fitting metal:   Fix the fitting metal to the wall by screws so that there is no clearance between them.   With the unit set up vertically, fix the fitting metal to the unit with screws while making an   adjustment at the long portion of the hole so that there is no clearance between the upper   surface and the fitting metal.   Installation of L-shaped metal   Fix to the unit by screws so that there is no clearance between the fitting metal and   the unit.   After confirming that the unit has been set up vertically to the floor, fix it to the floor by   bolt.   Piping connection   1. Connecting method   Apply refrigerant oil at half union and flare nut.   To bend a pipe, give the roundness as large as possible not to crash the pipe.   When connecting pipe, hold the pipe centre to centre then screw nut on by hand,refer   to Fig.   Be careful not to let sundries, such as sands enter the pipe.   Forced fastening without centering may   damage the threads and cause a gas leakage.   Pipe dia   Fastening torque   . 29.4N m   Liquid pipe 9.52mm(3/8")   Gas pipe 19.05mm(3/4")   . 117.7N m   15   Installation procedures   2. Piping connection of indoor unit   Arrangement of piping and drainage pipe   After opening inlet grill, you will see a control   box as shown in the Fig.   Remove the cover before wiring work.   Cut away, with a hammer or a saw, the lid for piping according to piping direction.   Insulation material   Drain hose   Connecting electric cable   for indoor and outdoor unit   Copper tube   According to the piping method, connect the piping on indoor unit with union of connecting   pipe.   Arrange the piping as per the wall hole and bind drain hose connecting electric cable and   piping together with polyethylene tape.   Insert the bound piping connecting electric cable and drain hose through wall hole to connect   with outdoor unit.   Arrangement of drain hose   Drain hose shall be placed in under place.   There should be a slope when arrange drain hose. Avoid up and down waves in drain hose.   Indoor unit   Up   Down   Bad   Slope   Good   If humidity is high, drain pipe( especially in room and indoor unit ) must be covered   with insulation material.   16   Installation procedures   3. Piping connection of outdoor unit.   Connect the connecting pipe and inlet and outlet liquid pipe according to the piping   method.   4.Purging method   Discharge the air out of the indoor unit and the refrigerant pipe by vacuumizing   (1) Fasten all the nuts of the indoor and outdoor pipes to make these parts out of leakage.   (2) Under the condition of the complete close of the indoor and outdoor valve center (both   liquid and gas side),dismount the repair valve cap.Vacuumizing through the charge   mouth of the repair valve.   (3) After vacuumizing fasten the repair valve,and dismount the cap of the big and small   stop valve,then loosen the stop valve center completely and fasten the big and small   stop valve.   5.Extra charging amount of the refrigerant   When piping is longer than 5 m, charge additional refrigerant specified in this list.   25m   Pipe length   5m   10m   325   15m   650   20m   975   30m   Refrigerant charge (g)   1625   1300   17   Electric wiring   Installation procedures   Note:   Electric wiring must be done by qualified person.   2 Use copper wire only, the parameter of connecting cable is H07RN-F 4G 0.75mm .   The power cable should be over 5G2.5mm2, the power cable and connecting cable   are self-provided.   The power supply connects from the outdoor unit.   Wiring of indoor unit   Insert the cable from outside the wall hole where piping already exist.   Pull it out from front.   Loosen terminal screws and insert cable end fully into terminal block, then tighten it.   Pull the cable gently to make sure it is tight.   OK   NO   Replace cover after wiring.   terminal block   Wiring of outdoor unit   Insert the cable from inside the wall hole   table clamp   where piping already exists.   Pull it out from front.   Loose terminal screw and insert cable end fully   into terminal block, then tighten it.   Pull the cable gently to make sure it is tight.   Replace cover after wiring.   HPU-42CH03 HPU-48CJ03 HPU-48HJ03 HPU-42HH03 HPU-42HI03 HPU-48HK03   INDOOR UNIT TERMINAL BLOCK   1 2 3 Y/G   OUTDOOR UNIT   TERMINAL BLOCK   Y/G   R S T N 1 2 3   POWER SUPPLY   Note:   When connecting indoor and outdoor wire, check the number on indoor and outdoor   terminal blocks.Incorrect wiring may damage air conditioner's controller or cause   operation failure.   18   Others   1. Pipe cutting and flaring   Be sure to carry out deburring after pipe cutting with a pipe cutter.   Insert flaring tool to make a flare.   Correct   Incorrect   Lean Damaged flare Crack   Partial Too outside   Pipe dia.   Dimension A(mm)   1.0 ~ 1.8   A Flaring tool   Liquid pipe   Gas pipe   9.52mm (3/8")   19.05mm (3/4")   1.4 ~ 2.2   2.Installation inspection and test run:   Please operate unit according to this Manual.   Items to be checked during test run. Please made a " "in " "   Are there any gas leakage?   How is insulation at piping connection carried out?   Are electric wires of indoor and outdoor unit firmly inserted into terminal block?   Is electric wiring of indoor and outdoor securely fixed?   Is draminage securely carried out?   Is earth line ( grounding ) securely connected?   Is power supply voltage abided by the code?   Is there any noise?   Is control display normal?   Is cooling operation normal?   Is room temp. regulator normal?   19   |