Haier AB482XCAAA AB242XCAAA User Manual

CASSETTE TYPE AIR CONDITIONER  
Operation & Installation  
Manual  
AB482XCAAA  
AB242XCAAA  
No.0010576262  
Please read this operation manual before using the air conditioner.  
Please keep this manual carefully and safely.  
Cautions  
Disposal of the old air conditioner  
Consult your local authorities for the name and  
address of the waste materials collecting  
centers and waste paper disposal services  
nearest to your house.  
Before disposing an old air conditioner  
that goes out of use, please make sure it's  
inoperative and safe. Unplug the air  
conditioner in order to avoid the risk of  
child entrapment.  
Safety Instructions and Warnings  
Before starting the air conditioner, read the  
information given in the User's Guide  
carefully. The User's Guide contains very  
important observations relating to the  
assembly, operation and maintenance of the  
air conditioner.  
It must be noticed that air conditioner  
system contains refrigerants, which require  
specialized waste disposal. The valuable  
materials contained in a air conditioner can  
be recycled. Contact your local waste  
disposal center for proper disposal of an  
old air conditioner and contact your local  
authority or your dealer if you have any  
question. Please ensure that the pipework  
of your air conditioner does not get  
damaged prior to being picked up by the  
relevant waste disposal center, and  
contribute to environmental awareness by  
insisting on an appropriate, anti-pollution  
method of disposal.  
The manufacturer does not accept  
responsibility for any damages that may  
arise due to non-observation of the following  
instruction.  
Damaged air conditioners are not to be  
put into operation. In case of doubt, consult  
your supplier.  
Use of the air conditioner is to be carried  
out in strict compliance with the relative  
instructions set forth in the User's Guide.  
Disposal of the packaging of your new  
air conditioner  
All the packaging materials employed in  
the package of your new air conditioner  
may be disposed without any danger to the  
environment.  
Installation shall be done by professional  
people, don't install unit by yourself.  
For the purpose of safety, the air  
conditioner must be properly grounded in  
accordance with specifications.  
The cardboard box may be broken or cut  
into smaller pieces and given to a waste  
paper disposal service. The wrapping bag  
made of polyethylene and the polyethylene  
foam pads contain no fluorochloric  
hydrocarbon.  
Always remember to unplug the air  
conditioner before opening inlet grill. Never  
unplug your air conditioner by pulling on the  
power cord. Always grip plug firmly and  
pull straight out from the outlet.  
All these valuable materials may be taken to a  
waste collecting center and used again after  
adequate recycling.  
1
Cautions  
All electrical repairs must be carried out  
by qualified electricians. Inadequate repairs  
may result in a major source of danger for  
the user of the air conditoiner.  
Do not damage any parts of the air  
conditioner that carry refrigerant by  
piercing or perforating the air conditioner's  
tubes with sharp or pointed items, crushing  
or twisting any tubes, or scraping the  
coatings off the surfaces. If the refrigerant  
spurts out and gets into eyes, it may result  
in serious eye injuries.  
Do not obstruct or cover the ventilation  
grille of the air conditioner. Do not put  
fingers or any other things into the  
inlet/outlet and swing louver.  
Do not allow children to play with the air  
conditioner. In no case should children be  
allowed to sit on the outdoor unit.  
2
Cautions  
Safety cautions  
Carefully read the following information in order to operate the airconditioner correctly.  
Below are listed three kinds of Safety Cautions and Suggestions.  
WARNING!  
CAUTION!  
Incorrect operations may result in severe consequences of death or serious injuries.  
Incorrect operations may result in injuries or machine damages; in some cases may  
cause serious consequences.  
INSTRUCTIONS: These information can ensure the correct operation of the machine.  
Be sure to conform with the following important Safety Cautions.  
The Safety Cautions should be at hand so that they can be checked at any time when needed.  
If the conditioner is transferred to the new user, this manual should be as well transferred to the new user.  
WARNING!  
Don't blow the human body with the cooling  
air too long, and don't let the room tempera-  
ture decrease too low  
Please let the dealer be responsible for installing  
the conditioner.  
Incorrect installation may cause water leak, elec-  
trical shock and fire hazard.  
either.  
Otherwise the one  
will feel unpleasant  
or harm ones' health.  
Don't put fingers or any other things into the  
inlet/outlet and swing louver while the condi-  
tioner is in operation.  
Because the highspeed  
fan is very dangerous  
If any abnormal phenomena is found (e. g.  
smell of firing), please cut off the power  
supply immediately, and contact the dealer  
to find out the handling method.  
In such case, to continue  
and may cause injuries.  
using the conditioner will  
damage the conditioner,  
Call the dealer to take measures to prevent the  
refrigerant from leaking.  
switch  
off  
and may cause electrical  
shock or fire hazard.  
If conditioner is installed in a small room be sure  
to take every measure in order to prevent suffoca-  
tion accident even in case of refrigerant leakage.  
When need maintenance and repairment,  
call dealer to handle it.  
Incorrect mainten-  
ance and repairment  
may cause water  
When conditioner is deinstalled or reinstalled  
dealer should be responsible for them.  
Incorrect installation may cause water leaking,  
electrical shock and fire hazard.  
leak, electrical shock  
and fire hazard.  
3
Cautions  
CAUTIONS!  
Don't operate the air-con-  
ditioner with damp hands.  
Otherwise will be shocked.  
Conditioner should not be used for any other  
purpose other than airconditioning.  
Don't use air-conditioner for any other special  
purposes, e.g. the preservation and protection  
of food, animals, plants,  
pecision apparatus as well  
as work of art, otherwise  
the qualities of these  
stuffs may be damaged.  
Only use correctly-typed fuse.  
May not use wire or any other  
materials replacing fuse, other-  
wise may cause faults or fire  
accidents.  
Don't place any burning unit  
in the air flow of air-conditioner,  
which may cause incomplete  
combustion.  
Don't dismantle the outlet of the outdoor unit.  
The exposure of fan is  
very dangerous which  
may harm human be-  
ings.  
No inflammable spray fluid  
should be permitted to be  
placed or used near to air-  
conditioner otherwise may  
cause fire accidents.  
When air-conditioner is co-used with other  
heat-radiator the frequent replacement of  
room atmosphere should be required.  
Inefficient venti-  
lation may cause  
suffocation.  
Air-conditioner should be  
cleaned only after power  
supply is cut off to keep  
from shock or hurt.  
After a long time use of air-conditioner the  
base should be checked for any damages.  
If the damaged base is  
not repaired, the unit  
may fall down and  
Don't clean air-conditioner  
with water.  
Otherwise may cause  
shock.  
cause accidents.  
No goods or nobody is permitted to placed on  
or stand on outdoor unit.  
The falling of goods and  
people may cause acci-  
dents.  
When use the fumigating insecticide don't  
open air-conditioner.  
Otherwise the poisonous chemicals may settle  
in air-conditioner which harm the health of  
chemical-allergic people.  
Pets and plants should not be blowed directly  
in the air flow.  
Otherwise will suffer  
damage.  
4
Introduction to Spare Parts  
Discharge unit (built in)  
In cooling operation,  
to discharge the  
water from inside the  
room.  
Drain Hose  
Swing fender  
(located in the outlet)  
Refrigerant pipe  
Cable line  
Outlet  
Earthing line  
Air filter  
(located in the suction grill)  
Suction grill  
5
Parts and Functions  
Operation  
Buttons and display of the wire controller.  
MODE  
CLOCK  
Used to select AUTO  
RUN, COOL, DRY,  
HEAT and FAN  
operation.  
Used to set correct time.  
TIMER  
Used to select  
TIMER ON,  
FAN SPEED  
TIMER OFF,  
TIMER ON/OFF.  
Used to select fan  
speed: LO, MID, HI,  
AUTO  
TEMP  
Used to select your  
desired temp.  
SET  
Used to confirm Timer  
TIME  
and Clock settings.  
Used to set clock and  
timer setting.  
SLEEP  
Power ON/OFF  
Used for unit start and  
stop.  
Used to select sleep  
mode.  
Cautions:  
Note:  
On cooling only unit, heating  
The above information is the explanation of  
the displayed information therefore varies  
with those displayed in actual operation.  
mode is not available.  
6
Parts and Functions  
Operation  
Buttons and display of the wire controller.  
Remote control  
COOL  
SLEEP  
AUTO  
DRY  
HEAT  
FAN SPEED  
TIMER ON  
OPERATING LAMP  
FAN OPERATION  
TIMER OFF  
CLOCK  
TEMP.  
Clock set  
When unit is started for the first time, clock should be adjusted as follows:  
Press CLOCK button, "AM"or "PM" flashes.  
7
Operation  
The air conditioner has the function of POWER  
FAILURE RESUME.  
Fan operation  
Enjoy yourself by just a gentle press.  
(1) Unit start  
(3) Fan  
Press ON/OFF button, unit starts.  
Previous operation status appears on display.  
(Not Timer setting)  
Press FAN button. For each press, fan speed  
changes as follows:  
Power indicator lights up.  
LOW  
MID  
HIGH  
(2) Select operation mode  
Press MODE button. For each press, operation  
mode changes as follows:  
Unit will run at selected fan speed.  
(4) Unit stop  
Press ON/OFF button.  
AUTO COOL  
DRY  
HEAT  
FAN  
Only time and room temp remains on LCD.  
All indicators go out.  
Vertical flap closed automatically.  
Hints  
Wire controller can memorize settings in each operation mode. To run it next time just select  
the operation mode and it will start with the previous setting.  
No reselecting is needed.(TIMER ON/OFF needs reselecting)  
In FAN mode, temp. can't be set.  
8
Operation  
AUTO RUN, COOL,HEAT and DRY operation  
Use COOL in summer.  
Use HEAT in winter.  
Recommendations  
Use DRY in spring,autumn and in damp climate.  
(1) Unit start  
(4) Fan speed selection  
Press ON/OFF button, unit starts.  
Press FAN button. For each press, fan speed changes  
Previous operation status appears on display  
(Not Timer setting). Power indicator lights up.  
as follows:  
AUTO  
(2) Select operation mode  
LOW  
AUTO  
MID  
HIGH  
Press MODE button. For each press, operation mode  
changes as follows:  
AUTO COOL  
DRY  
HEAT  
FAN  
Unit will run in operation mode displayed on LCD.  
Stop display at your desired mode.  
(3) Select temp. setting  
Press TEMP button  
(5) Unit stop  
Press ON/OFF button.  
Only time and room temp remains on LCD.  
All indicators go out.  
Vertical flap closes automatically.  
Hints  
Wire controller can memorize each operation  
status. When starting it next time, just press  
ON/OFF button and unit will run in previous  
status.  
Unit will start running to reach the temp. setting  
on LCD.  
9
Operation  
TIMER operation  
Set Clock correctly before starting Timer operation.  
You can let unit start or stop automatically at following time: Before you wake up in the  
morning, or get back from outside or after you fall asleep at night.  
TIMER ON/OFF  
(3)Timer setting  
(1)After unit start, select your desired  
operation mode.  
Operation mode will be displayed on LCD.  
Power indicator lights up.  
Every time the button is pressed, time increases 10min.  
If button is kept depressed, time will change quickly.  
Every time the button is pressed, time decreases 10min.  
If button is kept depressed, time will change quickly.  
Time will be shown on LCD. It can be adjusted within  
24hours.  
(2)TIMER mode selection  
Press TIMER button to change TIMER mode.  
Every time the button is pressed, display changes  
as follows:  
(4)Confirming your setting  
After setting correct time, press SET button to confirm  
"ON" or "OFF" stops flashing.  
ON  
blank  
ON  
OFF  
OFF  
Time displayed: Unit starts or stops at x hour x min (ON  
or OFF).  
Select your desired TIMER mode (ON or OFF)  
Timer mode indicator lights up.  
To cancel TIMER mode  
Just press TIMER button several times until TIMER mode disappears.  
Hints  
Wire controller possesses memory function, when use TIMER mode next time, just  
press SET button after mode selecting if timer setting is the same as previous one.  
10  
Operation  
TIMER ON-OFF  
(1)After unit start, select your desired  
operation mode  
(4) Time confirming for TIMER ON  
After time setting, press TIMER button to confirm.  
"ON" stops blinking, While "OFF" starts blinking.  
Operation mode will be displayed on LCD.  
Power indicator lights up.  
Time displayed: Unit starts at Xhour X min.  
(2) Press TIMER button to change TIMER  
mode  
Every time the button is pressed, display changes as follows:  
(5)Time setting for TIMER OFF  
Follow the same procedures in "Time setting for  
TIMER ON".  
ON  
blank  
ON  
OFF  
OFF  
(6)Time confirming for TIMER OFF  
After time setting, press SET button to confirm  
"OFF" stops flashing.  
ON  
Select  
.
OFF  
(3)Time setting for TIMER ON  
Time displayed: Unit stops at X hour X min.  
Press TIME button.  
Every time the button is pressed, time increases 10min.  
If button is kept depressed, time will change quickly.  
Every time the button is pressed, time decreases 10min.  
If button is kept depressed, time will change quickly.  
Time will be shown on LCD.  
It can be adjusted within 24hours.  
AM refers to morning and PM to afternoon.  
To cancel TIMER mode  
Just press TIMER button several times until TIMER mode disappears.  
According to the Time setting sequence of TIMER ON or TIMER OFF, either Start-Stop or Stop-Start can  
be achieved.  
11  
Operation  
Comfortable Sleep  
At night, before going to bed you  
can press down the SLEEP button  
on the controller and the air-  
conditioner will run by the  
comfortable sleeping mode to  
make you sleep more comfortable.  
In cooling, dehumidifying mode  
In heating mode  
Note:  
In AUTO mode, unit will run in SLEEP function according to the operation mode.  
After setting SLEEP function, it is forbidden to calibrate clock.  
If the set sleep-time does not reach 8 hours, the unit will stop operation automatically after  
set time is complete.  
Set "TIMER-OFF" function first, then set SLEEP, and the sleep-set is performance; set  
TIMER-ON function first, the sleep function can only be set before TIMER-ON; if set theSLEEP  
function first, the TIMER function can not be set.  
SLEEP RUN BEGINS  
SLEEP RUN STOPS  
SETTING T  
SHUT DOWN  
about 6 hrs  
1 hr  
1 hr  
1 hr  
about 3 hrs  
1 hr  
3 hrs  
SHUT DOWN  
SETTING T  
SLEEP RUN BEGINS  
SLEEP RUN STOPS  
Cooling mode  
Heat mode  
12  
Operation  
Power Failure Compensation (to be applied for a necessary situation)  
After the power failure compensation is set, if power failure suddenly occurs while the air conditioner  
is working, it will resume the previous working state when the power is supplied again.  
Setting Method: When the wire controller is on (excluding timer mode and fan mode), press  
the "Sleeping" button on the remote controller 10 times within 5 seconds, and  
after the buzzer rings 4 times, the air conditioner will enter the state of power  
failure compensation.  
Cancel Method: Press the "Sleeping" button on the wire controller 10 times within 5 seconds,  
and after the buzzer rings 2 timer, the power failure compensation mode will be  
cancelled.  
Notes: When a power failure suddenly occurs during the air conditioner is working after the power  
failure compensation is set, if the air conditioner will not be used for a long time, please cut off the  
power supply to prevent its operation from being resumed after the power is supplied again, or press  
the "Switch On/Off" button after the power comes again.  
Change-over switch  
ON  
OFF  
Mark  
1
2
3
4
Fixed Frequency  
Have rise and drop  
Swing  
The collection  
temperature of  
indoor unit  
Inverter  
No rise and drop  
Not Swing  
The collection  
temperature of wire  
controller.  
In this series changeover switch is set:  
1. OFF 2.OFF 3.ON 4.OFF  
13  
Maintenance  
(B) Wash with water.  
[Clean air filter]  
With too much dust, use soft brush and neutral  
detergent.  
Swing off the water, and then place in cool place.  
When having to clean, don't dismantle  
NOTE  
air-filter,otherwise may cause faults.  
In the environment where there is too  
much dust, air filter should be cleaned  
for more times.  
(about half a year one time)  
1. Open inlet grill  
5. Install air filter  
Press the elliptical "PUSH" knob, the inlet  
grill will automatically drop. (the inlet grill  
is catched with two pothooks)  
(1) Put filter into protruding parts at the top of  
the inlet grill.  
(2) Connect the two pothooks with inlet grill  
See 2  
Press the elliptical knob  
the inlet grill will  
automatically drop  
PUSH  
Pothook  
Open two  
pothooks  
2. Open two othooks  
3. Dismantle air filter  
Connet the two pothooks with inlet grill  
See 1.  
6. Close inlet grill  
7. Press the filter signal return key on the  
''  
''  
controller.  
[Clean inlet grill]  
1. Open inlet grill  
Drag the knob of  
the grill back lift  
the filter and take  
down.  
Air filter  
Press the elliptical "PUSH" knob, the inlet  
grill will automatically drop. (the inlet grill  
is catched with two pothooks)  
4. Clean  
CAUTION!  
Press the elliptical knob  
PUSH  
the inlet grill will  
automatically drop  
(A) Remove dust with vacuum filter.  
Pothook  
Open two  
pothooks  
14  
Maintenance  
2. Take off air-filter  
3. Take of inlet grill  
[Dismantle and install swing  
plate ]  
1. Fix the swing plate at the bottom.  
2. Dismantle the swing plate.  
CAUTION!  
4. Clean  
Use water to clean the plate and don't heavily  
scrub, otherwise the fine hair may fall off.  
Unscrew the screw at both ends of the swing  
plate.  
CAUTION!  
NOTE  
[Dismantle and install swing  
plate ]  
When the filter too much dust  
To spray the special detergent for vent fan or  
utensils.  
3. Install swing plate  
Lightly rotate swing plate to insert the ridge  
at both ends of the outlet into the groove  
and then screw up.  
5. Install inlet grill  
6. Install air filter  
7. Close inlet grill  
see 3  
see "Clean air filter"  
see 1  
[Clean outlet and shell]  
CAUTION!  
Don't use gasoline, benzene, dilutant,  
polishing powder, or liquid inseticide.  
15  
Maintenance  
Seasonal Reserve  
Post-season Care  
Operate the unit with FAN mode on a fair day for about half  
a day to dry the inside of the unit well.  
Stop operation and turn off the power supply switch .Electric  
power is consumed even the air conditioner is in stop.  
Clean the air filter, indoor unit and outdoor unit,and cover  
the unit with dustcoat.  
Pre-season Care  
See that there is no obstacles blocking the air  
inlet and air outlet of both indoor and outdoor  
unit to avoid reduce the working efficiency.  
Be sure to install the air filter, ensure that the air filter is not dirty. Otherwise may result in  
machine damages or cause malfunciton due th dust inside the unit  
To prevent compressor when start in HEAT mode,  
please cut in the power supply switch 12 hours  
before starting run,furthermore, always keep the  
power supply switch on during the using senson.  
NOTE  
1. The inner part of indoor unit must be cleaned. Consult dealer, because clean must be done by  
technician.  
In cooling operation, discharging system discharge water in room.  
2.  
16  
Trouble Shooting  
The followings are not malfuncition  
When the air conditoner is started, when the  
compressor starts or stops during operation  
or when the air conditioner is stopped,it som-  
etimes sounds ì Bi- Bi-î or ì Godo-Godoî . It is  
the flowing sound of the refrigerant , not a  
malfunction.  
Water flowing sound is heard  
Hua  
Hua  
This is caused by heat expansion or contra-  
ction of plastics  
Cracking sound is heard  
It smells.  
Air blown out from the indoor unit sometimes  
smells. The smell results from smells of  
furniture, paint , tobacco absorbed by indoor  
unit.  
During operation, white fog comes out of  
indoor unit.  
When in COOL or DRY mode, a thin water  
fog can be seen blown out of unit ,this is the  
condensed fog because the suddenly cooled  
indoor air is blown out.  
To prevent frost from being accumulated on the  
indoor unit heat exchanger, it sometimes auto-  
matically switched into the FAN mode,but it will  
soon back to the cooling mode.  
Automatically switch into FAN mode during  
cooling.  
The air conditioner cannot be restarted soon  
after it stops.  
Air conditioner does not start?  
This is because of the self-protection function  
of the system, therefore,it cannot be restarted  
for about three minutes after it stops.  
Please wait for  
three minutes  
17  
Trouble Shooting  
Air does not blow or the fan speed cannot be  
changed during drying.  
In DRY mode, when room temperature  
becomes 2 C higher than temperature setting,  
unit rill run intermittently at LO speed regardless  
of FAN setting  
This happens when the frost accumulated on  
the outdoor unit is removed (during defrosting  
operation).  
Water or vapor generated from the outdoor  
unit during heating.  
Defrosting operation  
To get ride of the excess heat, indoor fan will  
continue running for a while after unit autom-  
atically stops.  
During heating,indoor fan is still running even  
unit is stopped.  
Please check the following things about your air conditioner before making a  
service call.  
Unit fails to start.  
Is the earth leakage breaker  
in action ?  
Is city supply power normal ?  
Is the power supply switch on ?  
Be sure to turn off the power  
supply switch immediately and  
contact the sales dealer.  
ON  
OFF  
Power supply switch is not in  
ON position.  
18  
When Trouble Happens  
Insufficient cooling or heating  
The operation controller  
adjusted as required  
Air filter too dirty ?  
Horizontal swing louver  
upward ? (in HEAT mode)  
Any obstacle exists at the air  
inlet or outlet?  
Door or window left opened ?  
Insufficient cooling  
Too crowed in the room ?  
Sunlight direct into the  
room ?  
Any other heat sources in the  
room?  
Cooled air blown out ( when heating)  
When the air conditioner does not operate properly after  
you have checked the above-mentioned items or when  
following phenomenon is observed,stop the operation of  
the air conditioner and contact your sales dealer.  
1)The fuse or breaker often shuts down.  
2)Water drops off during cooling or drying operation.  
3)There is an irregularity in operation or abnormal sound that  
is audible.  
19  
Customer Need-to-know  
Customer Need-to-know  
Please install the air conditioner according to the requirements specified in this manual to ensure  
the air conditioner work well.  
Be careful not to scratch the surface of the case during moving the air conditioner.  
Please keep the installation manual for future reference when maintenance and changing installation place.  
After installation ,please use the air conditioner according to the specification in the operation  
manual.  
Using Directions  
Avoid direct sunlight and airflow  
Adjust suitable airflow direction  
Keep the proper indoor temperature.  
Too cool or hot is not good for your health.  
Furthermore,it will result in excessive  
consumption of electric power.  
Effectively use timer.  
Using TIMER mode, you can make the room  
temperature reach a suitable temperature when  
you wake up or back home.  
Optimal  
temper-  
ature  
ATTENTION: after finishing installation,confirm no refrigerant leakage.  
20  
Installation Procedure  
Installation  
Please ask the dealer or specialist to install, never try by the users themselves. After the installation please  
be sure of the following conditions.  
WARNING !  
Please call dealer to install the air-conditioner.  
Incorrect installation may cause water leaking, shock and fire hazard.  
CAUTION !  
Air-conditioner can't be installed in the envi-  
ronment with inflammable gases because the  
inflammable gases near to air-conditioner may  
cause fire hazard.  
Connect earthing wire.  
Earthing wire should not be con-  
nected to the gas pipe, water pipe,  
lightning rod or phone line, in-  
correct earthing may cause shock.  
Earthing  
Installed electrical-leaking circuit breaker.  
It easily cause electrical shock without circuit  
breaker.  
Use discharge pipe correctly to ensure efficient  
discharge.  
Incorrect pipe use may cause water leaking.  
[Location]  
Air-conditioner should be located in well-vented  
As required, take measures against heavy snow.  
and easily-accessible place.  
Air-conditioner should not be located in the  
following places:  
(a) Places with machine oils or other oil vapours.  
(b) Seaside with high salt content in the air.  
(c) Near to hot spring with high content of sulfide  
gases.  
(d) Area with frequent fluctuation of voltage e.g.  
factory, etc.  
(e) In vehicles or ships.  
[Wiring]  
Air-conditioner should be equipped with special  
power supply wire.  
[Operating noise]  
Chose the following locations:  
(a) Capable of supporting air-conditioner weight,  
don't increase operating noise and vibration.  
(b) Hot vapour from outdoor unit outlet and ope-  
rating noise don't disturb neighbour.  
(f) Kitchen with heavy oil vapour or humidity.  
(g) Near to the machine emitting electric-magnetic  
waves.  
No obstacles around the outdoor unit outlet.  
(h) Places with acid, alkali vapuor.  
TV, radio, acoustic appliances etc are at least 1 m  
far away to the indoor unit, outdoor unit, power  
supply wire, connecting wire, pipes, otherwise  
images may be disturbed or noises be created.  
21  
Installation Procedure  
To ensure proper installation, read "Cautions" carefully before working. After  
CAUTIONS:  
installation, start the unit correctly and show customers how to operate and  
maintain the unit.  
Meanings of Warning and Cautions:  
Warning! Serious injury or even death might happen, if it is not observed.  
Caution! Injury to people of damages to machine might happen, if it is not observed.  
WARNING!  
Installation shall be done by professional people, don't install unit by yourself. Incorrect installation will  
cause water leakage, electric shock or fire.  
Install unit as per the Manual. Incorrect installation will cause water leakage, electric shock or fire  
accident.  
Be sure to use specified accessaries and parts. Otherwise, water leakage, electric shock, fire accident or  
unit falling down may happen.  
Unit should be placed on a place strong enough to hold the unit. Or, unit will fall down causing injuries.  
When install the unit, take in consideration of storms, typhoom, earthquake. Incorrect installation may  
cause unit to fall down.  
All electric work shall be done by experienced people as per eocal code, regulations and this Manual.  
Use exclusive wire for the unit. Incorrect installation or undersized electric wire may cause electric  
shock or fire accident.  
All the wires and circuit shall be safe. Use exclusive wire firmly fixed. Be sure that external force  
will not affect terminal bolck and electric wire. Poor contact and installation may cause fire accident.  
Arrange wire correctly when connectin indoor and outdoor power supply. Fix terminal cover firmly to  
avoid overheat, electric shock or even fire accident.  
In case retrigerant leakage occurred during unit installation, keep a good ventilation in the room.  
Poisonous gas will occur when meet with fire.  
Check the unit upon installation. Be sure there is no leakage. Refrigerant will induce poisonous gas  
when meet heat source as heater, oven, etc.  
Cut power supply before touching terminal bolck.  
CAUTION!  
Unit shall be grounded. But grounding shall not be connected to gas pipe  
water pipe, telephone line. Poor grounding will cause electric shock.  
Be sure to install a leakage breaker to avoid electric shock.  
Earthing  
Arrange water drainage according to this Manual. Cover pipe with insulation materials in case  
dew may occur. Unproper installation of water drainage will cause water leakage and wer your furniture.  
To maintain good picture or reduce noise, keep at least 1 m from T.V. radio, when install indoor and ou  
tdoor unit, connecting wire and power line. (If the radio wave is relatively strong, 1 m is not enough  
to reduce noise).  
Don't install unit in following places:  
(a) Oil mist or oil gas exists, such as kitchen, or, plastic parts may got aged, or water leakage.  
(b) Where there is corrosive gas. Copper tube and welded part may be damaged due to corrosion,  
causing leakage.  
(c) Where there is strong radiation. This will affect unit's control system, causing malfunction of the unit  
(d) Where flamable gas, dirt, and volatile matter (thinner, gasoline) exist, These matter  
might cause fire accident.  
Refer to paper pattern when installing unit.  
Cautions for the installation personnel  
Don't fail to show customers how to operate unit.  
22  
Installation Procedure  
Installation tools  
Following in the list are the accessories  
supplied with the unit,which can be used  
as required  
The installation tools listed in the  
following sheet can be used as required.  
1. Screw driver  
2. Hacksaw  
Accessory parts  
No.  
Qty.  
3. Drill with a diameter of 60mm  
4. Inner hexagon spanner,shifting  
spanner  
5. Spanner (14, 17, 19,24,27mm)  
6. Pipe cutter  
7. Pipe expander  
8. Knife  
9. Pincers  
10. Leakage detector or soapy water  
11. Band tape  
1
2
1
4
Wire controller  
Wire clamp  
Heat  
insulation  
sheathing  
3
4
5
1+1  
1
Accesories  
Screw cap  
12. Scraper  
13. Refrigerant oil  
1+1  
Standard accessories  
The following parts mentioned in this  
manual are the installation accessories  
we prepared.  
Symbol  
Parts Name  
A
B
C
Adhesive tape  
Pipe clamp  
Connecting hose  
Drainage hose  
D
E
F
Gypsum powder  
Non-hydroscopic  
heat insulating material  
23  
Installation Procedure  
1
. BEFORE INSTALLATION  
<Don't discard any accessories until comp>  
Determine the way to carry unit to installation place.  
Don't remove packing until unit reaches installation place.  
If unpacking is unkavoidable, protect unit properly.  
2
2. SELECTION OF INSTALLATION PLACE  
(1) Installation place shall meet the following and agreed by customers:  
Place where proper air flow can be ensured.  
No block to air flow.  
Water drainage is smpoth.  
Place strong enough to support unit weight.  
Place where inclination is not evident on ceiling.  
Enough space for mainenance.  
Indoor and outdoor unit piping length is within limit. (Refer to Installation Manual for outdoor unit.)  
Indoor and outdoor unit, power cable, inter unit cable are at least 1 m away fromT.V. radop. This is helpful  
to avoid picture disturbance and noise. (Even if 1 m iskept, noise can still appear if radio wave is strong)  
(2) Ceiling height  
Indoor unit can be installed on ceiling of 2.5-3m in height. (Refer to Foeld setting and Installation Manual of  
ornament panel.)  
(3) Install suspending bolt. Check if the installation place is strong enough to hold weight. Take necessary  
measures in case it is not safe. (Distance between holes are marked on paper pattern. Refer to paper pattern  
for place need be reinforced)  
Air outlet  
Air outlet  
Air inlet  
1500 Over  
1500 Over  
24  
Installation Procedure  
3. PREPARATION FOR THE INSTALLATION  
3
(1) Position of ceiling opening between unit and suspending bolt.  
Refrigerant pipe  
Suspending bolts  
Suspending bracket  
Ceiling  
A
A
(Distance between suspending bolts)  
840(Indoor unit)  
890(Ceiling opening)  
950(Ornament panel)  
A
(2) Cut an opening in ceiling for installation if necessary. (when ceiling already exists.)  
Refer to paper pattern for dimension of ceiling hole.  
Connect all pipings (refrigerant, water drainage), wirings (inter unit cable) to indoor unit, before installation.  
Cut a hole in ceiling, may be a frame should be used to ensure a smooth surface and to prevent vibration.  
Contact your real estate dealer  
(3) Install a suspending bolt.  
(Use a M10 bolt)  
To support the unit weight, anchor bolt shall be used in the case of already exists ceiling. For new  
ceiling, use built-in type bolt or parts prepared in the field.  
Before going on installing adjust space between ceiling.  
<Installation example>  
Roof  
Anchor bolt  
Long nut  
Suspending bolt  
Note: All the above mentioned parts shall be prepared in field.  
Ceiling  
25  
Installation Procedure  
4
4. INSTALLATION OF INDOOR UNIT  
In the case of new ceiling  
(1) Install unit temporally  
Put suspending bracket on the suspending bolt. Be sure to use nut and washer at both ends of the bracket.  
(2) As for the dimensions of ceiling hole, see paper pattern. Ask your real estate dealer for details.  
Center of the hole is marked on the paper pattern.  
Center of the unit is marked on the card in the unit and on the paper pattern.  
5
6
Mount paper pattern onto unit using 3 screws . Fix the corner of the drain pan at piping outlet.  
< After installation on the ceiling >  
(3) Adjust unit to its right position. (Refer to preparation for the installation-(1))  
(4) Check unit's horizontal level.  
Watert pump and flating switch is installed inside indoor unit, check four corners of the unit for its level  
using horizontal compartor or PVC tube with water. (If unit is tilting against the direction of water drainage,  
problem may occur on floating switch, causing water leakage.)  
(5) Remove the washer mounlting  
(6) Remove the paper pattern.  
2
, and tighten the nut above.  
Nut (Prepare in feild)  
Washer (Prepared in feild)  
In the case of ceiling already exists  
(1) Install unit temporally  
Put suspending bracket on the suspending bolt.  
Be sure to use nut and washer at both ends  
of the bracket. Fix the bracket firmly.  
Suspending bolts  
(2) Adjust the height and position of the unit.  
(Refer to preparation for the installation (1) ).  
Fasten (double nuts)  
(3) Proceed with  
and  
of "In the case of new ceiling".  
4
3
Insert  
Washer fixing pad  
(prepared in feild)  
[ secure the washer firmly]  
Level  
Polythene pipe  
Screws at the piping outlet is fixed at the corner  
of drain pan.  
Center of ceiling hole Paper pattern  
Screw (accessory)  
Paper pattern  
5
Screw (accessory)  
[Fix the paper pattern]  
26  
Installation Procedure  
5
(As for outdoor piping, please refer to installation Manual of outdoor unit.)  
Outdoor is precharged with refrigerant.  
5. REFRIGERANT PIPING  
Be sure to see the Fig.1, when connecting and removing piping from unit.  
For the size of the flare nut, please refer to Table 1.  
Apply refrigerant oil at both inside and outsid of l flare nut. Tighten it band tight 3-4 turns then tighten it.  
Use torque specified in Table 1. (Too much force may damage flare nut, causing gas leakage).  
Check piping joints for gas leakage. Insulate piping as shown in Fig. below.  
Cover joint of gas piping and insulator  
with seal.  
Table 1  
7
Tighten  
torque  
Pipe  
size  
11  
Flare shape  
Medium size seal pad  
Apple refrigerant oil  
A(mm)  
8.3~8.7  
(accessory)  
(Cover the piping joint  
.
.
1420~1720N cm  
(144~176kgf cm)  
with seal pad.)  
Clamp 3  
6.35  
.
.
Torque spanner  
3270~3990N cm  
(333~407kgf cm)  
12.0~12.4  
9.52  
12.7  
R0.4 ~ 0.8  
2
.
.
4950~6030N cm  
(504~616kgf cm)  
8
15.4~15.8  
18.6~19.0  
22.9~23.3  
45  
Insulator  
(accessory)  
(For liquid pipe)  
Insulator(accessory)7  
(For gas pipe)  
spanner  
.
.
6180~7540N cm  
(630~770kgf cm)  
15.88  
19.05  
Piping joing  
Flare nut  
Gas pipe  
Liquid pipe  
.
.
9720~11860N cm  
(990~1210kgf cm)  
6
6. INSTALLATION OF WATER DRAINAGE PIPE  
(1) Install water drainage pipe  
Pipe dia, shall be equal or larger than that of unit piping.(pipe of polyethylent; size: 25mm; O.D:32mm)  
Drain pipe should be short, with a downward slope at least 1/100 to prevent air bag from happening.  
If downward slope can't be made, take other measures to lift it up.  
Keep a distance of 1-1.5m between suspending brackets, to make water hose straight.  
1-1.5m  
Slope over 1/100  
Use the self-provided stiff pipe and clamp with unit. Insert water pipe into water plug until it reaches the  
1
white tape. Tighten the clip until head of the screw is less than 4mm from hose.  
Wind the drain hose to the clip using seal pad 9 .  
Large size seal pad  
(accessory)  
10  
Insulate drain hose in the room.  
Clamp  
Clamp  
(accessory)  
Tape (White)  
Self-provided stiff pipe  
<Cautions for the drain water lifting pipe>  
4mm below  
Installation height shall be less than 280mm.  
There should be a right angle with unit, 300mm from unit.  
Suspending bracket  
1~1.5m  
300mm below  
Self-provided stiff pipe  
(accessory)  
Drain hose  
(accessory)  
drain water lifting pipe  
Clamp  
(accessory)  
(Note)  
The slope of water drain hose (1) shall be within 75mm, don't apply too much force on it.  
If several water hoses join together, do as per following proceedures.  
Connect water hoses with a T joint.  
Specifieations of the water hoses shall meet the requirements for the unit running.  
27  
Installation Procedure  
(2) Check if water drainage is smooth after installation.  
Charge, through air outlet or inspecting hole, 1200ccd water to see water drainage.  
After wiring  
Check water drainage in cooling operation.  
When wiring is not complete  
Remove cover of control box, short connect "CHECK" terminal of the indoor unit, which is on the uper  
part of indoor unit PCB. Connect 1PH power to terminal 1 and 2 on terminal block.  
Note, in this operation, fan will be running.  
Upon confirmation of a smooth water drainage, be sure to cut off power supply  
and remove short connection of "CHECK" terminal.  
Method of water charging  
Maintenance  
Self-provided stiff pipe  
Water drainage port for  
maintenance  
Inspecting hole  
(Drain water from  
this hole)  
Charge water from  
100mm  
inspecting hole  
Watering can of plastic  
pipe should be about  
100 mm long  
Charge water from  
air outlet  
PCB on  
indoor unit  
Terminal block  
Cover of controll box  
28  
Installation Procedure  
7. WIRING  
7
All supplied parts. materials and wiring operation must in appliance with  
local code and regulations.  
Use copper wire only.  
When make wiring, please refer to wiring diagram also.  
All wiring work must be done by qualified electricians.  
A circuit breaker must be installed, which can cut power supply to all system.  
See Installation Manual of outdoor unit for specifications of wires, circuit breaker, switches and wiring etc.  
Connecting of unit  
Remove cover of switch box (1) , drag wires into rubber tube A, then, after proper wiring with other wires,  
tighten clamp A. Connect wires of correct pole to the terminal block inside.  
Wind seal 12 around wires. (Be sure to do that, or, dew may occur).  
Upon connecting, replace control box cover (1) and (2).  
Terminal block  
Cover of control box(2)  
*
Don't fail to seal it, or water may come in.  
Grounding lead  
Cover of control box(1)  
Rubber tube  
Note: Have it sealed, leaving no space.  
Seal pad (small size 12  
(Wind around wire)  
Rubber tube A  
)
In  
Out  
Attach seal pad Field wiring  
<<WARNING>>  
Don't connect wires of  
the same specifications of the different  
specifications.  
Connect wires of the  
same specifications  
at two sides.  
Don't connect wires  
Obscrve the following when connecting power supply  
terminal block:  
at one side.  
Don't connect wires of different specifications to the same  
terminal block.  
(Loose wire may cause overheating of circuit)  
Connect wires of same specifications as shown in right Fig.  
8
8. WIRING EXAMPLE  
As for outdoor unit circuit, please see Installation Manual of outdoor unit.  
Note: All electric wires have their own poles, poles must match that on terminal block.  
9
INSTALLATION OF WIRE CONTROLLER  
1. Remove upper part of wire controller  
Remove upper part of wire controller  
PCB is mounted on lower part of wire controller, be careful not to damage it.  
Upper part of wire  
controller  
Lower part of wire  
controller  
21  
29  
Installation Procedure  
2. Install wire controller  
(1) For exposed installation,  
use 2 wood screws (accessory).  
(2) For recessed installation,  
use 2 wood screws (accessory).  
Note  
Try as far as possible a flat surface for installation. Don't use excessive  
force when tightening screws, or lower part might got deformed.  
3. Indoor unit wiring  
Hint  
Connect terminals (A,B,C,D) on lower part of wire controller  
to terminals (A,  
B,C,D) on PCB of indoor unit.  
When make wiring, please keep  
a distance between wires and  
power supply cord.  
Wire size  
wiring from here  
C D  
A B  
Cord kind Shield wire (4 core) (refer to Hint 3,4)  
Lower part of  
wire controller  
2
0.33mm  
Size  
Use shielede wires for telecommunication  
between wire controller and indoor unit;  
indoor unit and outdoor unit. Ground the  
shield on one side.  
Otherwise misoperation because of  
noise may occur.  
Signal wire is self-provided.  
Shielded wire  
ground  
Upper part of  
wire controller  
30  
Installation Procedure  
Hint  
Tread surface of the terminal well so that  
shielding may not contact other part.  
4. Replace the upper part of wire controller  
Be careful not to press the wiring.  
Hint  
1. Switch box and cord for wiring are not supplied.  
2. Don't touch PCB with hand.  
10  
9. INSTALLATION OF ORNAMENT PANEL  
Be sure to show customers Operation Manual and guide them how to operate unit  
correctly. Before installation. read also the Installation Manual of indoor unit.  
With this ornament , 2 or 3 air flow direction is not available.  
Suitable height is 3 m.  
Cautions for the installation  
Accessory  
Pad  
Pad  
1. Prepare ornament panel Handling of ornament panel  
Ornament panel shall not be placed face down or against wall, neither  
on an uneven object.  
Don' t bend carelessly the swing flap, or, problem may occur.  
(1) Remove air inlet grill from ornament panel *  
1
2
Push in the bar on inlet grill and lift it up. (Refer to Fig. 1)  
Lift it up for about 45 degree and remove it from ornament. Tear off adhesive  
tape fixing air filter on the back of the air inlet grill. (Refer to Fig. 2)  
Bar  
Fig. 1  
(2) Remove cover plate at corner  
Tear off the adhesive tape, and slide it off. (Refer to Fig. 3)  
Adbesive tape  
45  
Slide  
Fig. 2  
Fig. 3  
31  
Installation Procedure  
2. Mounting on high ceiling  
(1) Ornament panel can be mounted on ceiling as high as 3 m.  
(2) Please install pad as accessary.  
Cut open the pad along cutting ling. Use part a only and discard part b . (Refer to Fig. 4)  
Install part a of the pad on the place shown in Fig. 5. Refer to Fig. 6.  
1
2
Leave no space.  
Cutting line  
Place it on the frame.  
b
a
50  
100  
Part a of the pad  
Fig. 4  
Fig. 6  
Part a of the pad  
Swing flap motor  
Side of ornament panel  
Fig. 5  
(3)Wiring on ornament panel  
Connecting of wiring of the swing  
flap motor on ornament panel. (2 places)  
(Refer to Fit . 10)  
If connecting is not made, error code  
(A7) appears on remote controller. So,  
make proper connecting.  
Fig. 10  
Side of indoor unit  
Wiring diagram  
3. Install ornament panel on indoor unit.  
For indoor unit installation, please  
refer to Installation Manual.  
Hook  
1
(1)  
As shown in Fig . 7, match the position of swing  
flap motor with that of the indoor unit piping hole ,  
so that ormament panel can be placed on to indoor  
unit.  
Holding ring  
2
Piping hole position  
(2)  
1
Installation of ornament panel  
2
Place the holding ring on swing flao motor side  
teporarily on hooks of the indoor unit. (2 pcs)  
Put the other two holding rings on the hooks at both  
side of the indoor unit. (Care should be taken not to  
push wiring of swing flap motor into seals).  
Screw in all 4 screws under holding ring for about  
15mm. (Pancl will rise).  
Adjust the ornament panel as per Fig. 7 to cover  
opening on the ceiling.  
Tighten screws to redrce the thickness of seals  
between ornament and indoor unit to 5-8mm.  
Swing flap motor  
3
2
3
4
5
4
Fig. 7  
Seal  
Indoor unit  
Ceiling material  
_
5
8mm  
Ornament panel  
Caution  
If screws are not tighten tight,  
problems in Fig, 8 might occur.  
Tighten screws properly.  
If indoor unit is at horizontal level and water  
drainage is smooth, then, indoor unit height  
can be adjusted throrgh holes at corners of  
ornament panel.  
If there are still space  
after tightening of screws,  
please readjust the height  
of indoor unit.  
Gas leakage.  
(Refer to Fig. 9)  
Gas leakage  
from roof.  
Mist exists and drop down.  
Fig. 8  
Contamination  
Leave no space.  
Fig. 9  
32  

Acura Music Link BAM30192 User Manual
Briggs Stratton 141297 User Manual
Bryant Single Packaged And Gas Furnace System 577D User Manual
BT Freestyle 3500 User Manual
Casio CELVIANO AP 33 User Manual
Casio Printer SERIESIT 9000 User Manual
Datacard Group RP90 User Manual
Epson Stylus Photo RX700 User Manual
Harbor Freight Tools DRILL MASTER 67031 User Manual
Havis Shields C SM 800 User Manual