IMI CORNELIUS INC g One Cornelius Place g Anoka, MN 55303-6234  
Telephone (800) 238-3600  
Facsimile (612) 422-3246  
Ins tallation/Service  
Manual  
VENTURE POST--MIX DISPENSER  
W/BUILT--IN COLD CARBONATOR  
(R--134A REFRIGERANT)  
IMPORTANT:  
TO THE INSTALLER.  
It is the res pons ibility of the Ins taller  
to ens ure that the water s upply to the  
dis pens ing equipment is provided  
with protection agains t backflow by  
an air gap as defined in ANSI/ASME  
A112. 1.2-1979; or an approved  
vacuum breaker or other s uch  
method as proved effective by tes t.  
Water pipe connections and fixtures  
directly connected to a potable water  
s upply s hall be s ized, ins talled, and  
maintained according to Federal,  
State, and Local laws .  
Part No. 312027000  
July 18, 1995  
Revised: April 1, 1999  
Control Code D  
THIS DOCUMENT CONTAINS IMPORTANT INFORMATION  
This Manual must be read and understood before installing or operating this equipment  
PRINTED IN U.S.A  
Ó IMI CORNELIUS INC; 1995-99  
TABLE OF CONTENTS (contd)  
Page  
SANITIZING SYRUP SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
19  
CHECKING DROP-IN REFRIGERATION ASSEMBLY CONDENSER COIL  
FOR RESTRICTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
19  
19  
CHECKING ICE WATER BATH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
CARBONATOR WATER PUMP YEARLY MAINTENANCE OR AFTER WATER  
SYSTEM DISRUPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
19  
19  
21  
CLEANING CO2 GAS CHECK VALVES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
SERVICE AND MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
PREPARING UNIT FOR SHIPPING, STORING, OR RELOCATING . . . . . . . . . .  
HOOD AND FRONT PANEL REMOVAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
HOOD REMOVAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
FRONT ACCESS PANEL REMOVAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
PERIODIC INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
ADJUSTMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
ADJUSTING CO2 REGULATORS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
ADJUSTING DISPENSING VALVES WATER FLOW RATE . . . . . . . . . . . . .  
21  
21  
21  
21  
21  
21  
21  
23  
ADJUSTING WATER-TO-SYRUP RATIO” (BRIX) OF DISPENSED  
PRODUCT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
25  
26  
26  
27  
28  
28  
29  
CLEANING DROP-IN REFRIGERATION ASSEMBLY CONDENSER COIL . . . .  
CHECKING ICE WATER BATH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
CLEANING WATER TANK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
CLEANING AND SANITIZING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
DAILY CLEANING OF UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
SANITIZING POST-MIX SYRUP SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . .  
CARBONATOR WATER PUMP YEARLY MAINTENANCE OR AFTER WATER  
SYSTEM DISRUPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
31  
33  
34  
35  
35  
35  
35  
42  
REPLENISHING CO2 SUPPLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
REPLENISHING SYRUP SUPPLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
SYRUP TANK SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
BAG-IN-BOX SYRUP SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
SYRUP FLAVOR CHANGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
CLEANING CO2 SYSTEM CO2 GAS CHECK VALVES . . . . . . . . . . . . . . . . . . . . .  
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
TROUBLESHOOTING POST-MIX SYSTEM SYSTEM . . . . . . . . . . . . . . . . . . . . . .  
WATER-TO-SYRUP RATIO” TOO LOW OR TOO HIGH . . . . . . . . . . . . . . .  
42  
42  
ADJUSTMENT OF DISPENSING VALVE SYRUP FLOW CONTROL DOES  
NOT INCREASE TO DESIRED WATER-TO-SYRUP RATIO. . . . . . . . . . . .  
42  
ADJUSTMENT OF DISPENSING VALVE SYRUP FLOW CONTROL DOES  
NOT DECREASE TO DESIRED WATER-TO-SYRUP RATIO. . . . . . . . . . .  
43  
43  
DISPENSED PRODUCT CARBONATION TOO LOW. . . . . . . . . . . . . . . . . . .  
DISPENSED PRODUCT COMES OUT OF DISPENSING VALVE CLEAR  
BUT FOAMS IN CUP OR GLASS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
43  
DISPENSED PRODUCT PRODUCES FOAM AS IT LEAVES DISPENSING  
VALVE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
43  
44  
44  
NO PRODUCT DISPENSED FROM ALL DISPENSING VALVES. . . . . . . . .  
ONLY CARBONATED WATER DISPENSED. . . . . . . . . . . . . . . . . . . . . . . . . . .  
312027000  
ii  
TABLE OF CONTENTS (contd)  
Page  
44  
ONLY SYRUP DISPENSED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
TROUBLESHOOTING REFRIGERATION SYSTEM . . . . . . . . . . . . . . . . . . . .  
COMPRESSOR DOES NOT OPERATE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
45  
45  
COMPRESSOR WILL NOT STOP AFTER SUFFICIENT ICE BANK IS  
PRODUCED. (NOTE: ICE BANK SHOULD JUST COVER CONTROL  
BULB). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
45  
COMPRESSOR OPERATES CONTINUOUSLY BUT DOES NOT FORM  
SUFFICIENT ICE BANK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
46  
46  
47  
AGITATOR MOTOR NOT OPERATING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
LIST OF FIGURES  
FIGURE 1. VENTURE SIX-FLAVOR POST-MIX DISPENSER . . . . . . . . . . . . . . .  
3
6
7
FIGURE 2. FLOW DIAGRAM (FIVE-FLAVOR UNIT WITH BUILT-IN COLD  
CARBONATOR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
FIGURE 3. FLOW DIAGRAM (SIX-FLAVOR UNIT WITH BUILT-IN COLD  
CARBONATOR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
FIGURE 4. SYRUP INLET SUPPLY LINE CONNECTIONS (SIX-FLAVOR  
UNIT SHOWN) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
11  
22  
23  
24  
28  
FIGURE 5. DISPENSER COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
FIGURE 6. SF-1 DISPENSING VALVE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
FIGURE 7. UF-1 DISPENSING VALVE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
FIGURE 8. WATER TANK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
FIGURE 9. WATER STRAINER SCREEN AND DOUBLE-LIQUID CHECK  
VALVE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
33  
34  
35  
FIGURE 10. LIQUID CHECK VALVE ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . .  
FIGURE 11. CO2 GAS CHECK VALVE ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . .  
FIGURE 12. WIRING SCHEMATIC FOR ELECTRONIC ICE BANK CONTROL  
(OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
36  
37  
38  
FIGURE 13. WIRING DIAGRAM (50 AND 60 HZ UNIT WITH 1/3 H.P.  
REFRIGERATION ASSEMBLY) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
FIGURE 14. WIRING DIAGRAM (60 HZ UNIT WITH 1/4 H.P. REFRIGERATION  
ASSEMBLY AND BUILT-IN COLD CARBONATOR) . . . . . . . . . . . . . . . . . . . . . . . .  
FIGURE 15. WIRING DIAGRAM (50 HZ UNIT WITH 1/4 H.P. REFRIGERATION  
ASSEMBLY AND BUILT-IN COLD CARBONATOR) . . . . . . . . . . . . . . . . . . . . . . . .  
39  
40  
40  
FIGURE 16. WIRING DIAGRAM (SF-1 DISPENSING VALVE) . . . . . . . . . . . . . . .  
FIGURE 17. WIRING DIAGRAM (UF-1 DISPENSING VALVE) . . . . . . . . . . . . . . .  
LIST OF TABLES  
TABLE 1. DESIGN DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
TABLE 2. LOOSE-SHIPPED PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
4
9
iii  
312027000  
SAFETY INFORMATION  
Recognize Safety Information  
This is the safety-alert symbol. When you see this  
symbol on our machine or in this manual, be alert to  
the potentially of personal injury.  
Follow recommended precautions and safe operating  
practices.  
Unders tand Signal Words  
DANGER  
A signal word - DANGER, WARNING, OR CAUTION  
is used with the safety-alert symbol. DANGER identi-  
fies the most serious hazards.  
WARNING  
Safety signs with signal word DANGER or WARNING  
are typically near specific hazards.  
General precautions are listed on CAUTION safety  
signs. CAUTION also calls attention to safety mes-  
sages in this manual.  
CAUTION  
Follow Safety Ins tructions  
Carefully read all safety messages in this manual and on your machine safety signs. Keep safety signs in  
good condition. Replace missing or damaged safety signs. Learn how to operate the machine and how to  
use the controls properly. Do not let anyone operate the machine without instructions. Keep your machine in  
proper working condition. Unauthorized modifications to the machine may impair function and/or safety and  
affect the machine life.  
CO (Carbon Dioxide) Warning  
2
CO2 Dis places Oxygen. Strict Attention mus t be obs erved in the prevention of CO2 (carbon dioxide)  
gas leaks in the entire CO2 and s oft drink s ys tem. If a CO2 gas leak is s us pected, particularly in a  
s mall area, immediately ventilate the contaminated area before attempting to repair the leak. Pers on-  
nel expos ed to high concentration of CO2 gas will experience tremors which are followed rapidly by  
los s of cons cious nes s and s uffocation.  
Shipping, Storing, Or Relocating Unit  
CAUTION: Before s hipping, s toring, or relocating this Unit, the s yrup s ys tems mus t be s anitized and  
all s anitizing s olution mus t be purged from the s yrup s ys tems . All water mus t als o be purged from  
the plain and carbonated water s ys tems . A freezing ambient temperature will caus e res idual water  
remaining ins ide the Unit to freeze res ulting in damage to internal components of the Unit.  
1
312027000  
THIS PAGE LEFT BLANK INTENTIONALLY  
312027000  
2
GENERAL INFORMATION  
IMPORTANT: To the us er of this manual - This manual is a guide for ins talling, operating, and main-  
taining this equipment. Refer to the Table of Contents for page location for detailed information per-  
taining to ques tions that aris e during ins tallation, operation, s ervice, or maintenance of this  
equipment.  
GENERAL DESCRIPTION  
This section gives the Unit description, theory of operation, and design data for the five and six-flavor Ventures  
Post-Mix Dispensers with Built-In Cold Carbonators (hereafter referred to as Units).  
This Unit must be installed and serviced by a qualified Service Person. This Unit contains no User serviceable  
parts.  
UNIT DESCRIPTION  
The Units are compact with high-impact and corrosion-resistant moulded lower housings and may be island-  
mounted or installed on a front or rear counter. Their refrigeration assemblies are the 1/3 H.P. drop-in type that  
can be easily removed for service and maintenance. The Units are equipped with built-in cold carbonators with  
their carbonated water tanks located inside the Units lower housings water tanks. Adjustable syrup flow  
regulators, located on the electrically operated dispensing valves, are easily accessible to control water-to-syrup  
Ratio” of the dispensed product.  
Installation of the Unit on a countertop, installation of LOOSE-SHIPPED PARTS, connection of plain water and  
syrup supplies, adjustment of CO2 regulators, filling water tank with water, and plugging the Unit power cord into  
an electrical outlet is all that is required for operation.  
NOTE: Optional 4-inch Legs (P/N 314744000) that will elevate the Unit 4-inches above the countertop  
are available. When ordering legs , order a quantity of four.  
CAUTION: Before s hipping, s toring, or relocating this Unit, the s yrup s ys tems mus t be  
s anitized and all s anitizing s olution mus t be purged from the s yrup s ys tems . All water mus t  
als o be purged from the plain and carbonated water s ys tems . A freezing ambient  
environment will caus e res idual water in the Unit to freeze res ulting in damage to internal  
components .  
FIGURE 1. VENTURE SIX-FLAVOR POST-MIX DISPENSER  
3
312027000  
WARRANTY REFERENCE INFORMATION  
Warranty Regis tration Date  
(to be filled out by cus tomer)  
Unit Part Number:  
Serial Number:  
Ins tall Date:  
Local Authorized  
Service Center:  
Table 1. Des ign Data  
Unit Part Numbers  
see Unit Nameplate  
Overall Dimensions:  
Width  
16-1/4 inches  
27 5/8 inches  
24 1/2 inches  
Height  
Depth  
Weights:  
Shipping (one carton)  
127 Pounds  
115 Pounds  
30 Pounds  
66 Pounds  
Dry Weight (Approximate)  
Ice Bank Weight (approximate)  
Drop-In Refrigeration Assembly  
Water Tank Capacity (no ice bank) approximate  
8-3/4 Gallons  
Dispensing Rate:  
12-0z Drinks 2/min. or below  
*70 (see NOTE)  
NOTE: Number of drinks dis pens ed 40° F or below with 75° F s yrup and water inlet temperature and  
75° F ambient.  
Refrigeration System:  
Compressor Horsepower  
1/3 H.P.  
Refrigerant Type and Amount  
See Unit Nameplate  
Ambient Operating Temperature  
Electrical Requirements:  
40° F to 100° F  
See Unit Nameplate  
312027000  
4
THEORY OF OPERATION  
(see applicable Figure 2 or 3)  
WARNING: CO2 dis places oxygen. Strict attention mus t be obs erved in the prevention of  
CO2 (carbon dioxide) gas leaks in the entire CO2 and s oft drink s ys tem. If a CO2 gas leak is  
s us pected, particularly in a s mall area, immediately ventilate the contaminated area before  
attempting to repair the leak. Pers onnel expos ed to high concentration of CO2 gas will experience  
tremors which are followed rapidly by los s of cons cious nes s and s uffocation.  
NOTE: The s ix-flavor (s ee Figure 3) Unit was s et up at the factory to dis pens e a s till (noncarbonated)  
drink from No. 3 dis pens ing valve and carbonated drinks from the remaining dis pens ing valves .  
A CO2 cylinder delivers carbon dioxide (CO2) gas through adjustable CO2 regulators to applicable syrup tanks  
or bag-in-box syrup system syrup pumps and to a built-in carbonator located inside the Unit. Plain water is  
pumped into the carbonator carbonated water tank by a water pump and is carbonated by regulated CO2 gas  
pressure also entering the tank. When a dispensing valve is opened, CO2 gas pressure exerted upon the syrup  
tank or on the bag-in-box system syrup pump, pushes syrup through the Unit syrup cooling coils, and on to the  
dispensing valve. Carbonated water is pushed by CO2 gas pressure from the carbonated water tank and  
passes through the Unit carbonated water cooling coils, and on to the dispensing valve.  
Syrup and carbonated water meet simultaneously at the dispensing valve resulting in a carbonated drink being  
dispensed. On the six-flavor Unit, a still (noncarbonated) drink is dispensed from the No. 3 dispensing valve in  
the same manner as the carbonated drink except plain water is substituted for carbonated water.  
The carbonated water tank is replenished when the carbonated water level inside the tank drops, which in turn  
automatically starts the carbonator water pump. When the carbonated water level inside the tank has been re-  
plenished, the carbonated water pump will stop.  
5
312027000  
312027000  
6
7
312027000  
THIS PAGE LEFT BLANK INTENTIONALLY  
312027000  
8
INSTALLATION  
This section covers unpacking and inspection, selecting location, installing the Unit, preparing the Unit for op-  
eration, and Unit operation.  
UNPACKING AND INSPECTION  
NOTE: The Unit was thoroughly ins pected before leaving the factory and the carrier has accepted and  
s igned for it. Any damage or irregularities s hould be noted at the time of delivery (or not later than 15  
days from date of delivery) and immediately reported to the delivering carrier. Reques t a written ins pec-  
tion report from Claims Ins pector to s ubs tantiate any neces s ary claim. File claim with the delivering  
carrier, not with IMI Cornelius Inc.  
1. After the Unit has been unpacked, remove shipping tape and other packing material.  
2. Lift hood straight up and off the Unit.  
3. Remove four shipping hex nuts that secure the drop-in refrigeration assembly in the Unit.  
4. Unpack LOOSE-SHIPPED PARTS. Make sure all items are present and in good condition.  
Table 2. Loos e-Shipped Parts  
Name  
Item  
No.  
Part No.  
317659039  
317660000  
3573  
5-FL 6-FL  
1
Drip Tray  
1
1
1
--  
2
1
2
2
1
--  
1
1
1
1
2
1
2
2
1
1
2
Cup Rest  
3
Rear access Panel  
Adaptor Fitting, 7/16-20 (2)  
4
17619300  
187254000  
318516000  
311304000  
309852000  
77040900  
5
Sheet Metal Screw, Phil Truss Hd; Type A, No. 6 by 3/8-in. Long  
Drain Hose Clamp  
6
7
Tapered Gasket, Black  
8
Tubing Clamp, .669 I.D. Open .571 I.D. Closed  
Fitting, 90° Swivel Elbow  
9
10 3297  
Water Only Lever Kit, UF-1 Dispensing Valve (see Note)  
NOTE: Loos e-s hipped with Six-Flavor Dis pens ers equipped UF-1 dis pens ing valves .  
IDENTIFICATION OF LOOSE-SHIPPED PARTS  
1. DRIP TRAY (item 1) to be installed on the Unit, then CUP REST (item 2) to be installed in the drip tray.  
2. REAR ACCESS PANEL (item 3) to be installed over Unit base back access hole if power cord, drain  
hoses, and inlet supply lines will not be routed out back of the Unit. Rear access panel to be secured to the  
Unit with SHEET METAL SCREWS (item 5).  
3. FITTING (item 4) is used to connect plain water inlet source line to the six-flavor Dispenser plain water inlet  
line that provides plain water to the No. 3 dispensing valve.  
4. DRAIN HOSE CLAMP (item 6) is used to connect drain hose (not provided) to the Dispenser drip tray.  
5. FITTING, 90° SWIVEL ELBOW (item 9) is used to connect plain water source line to the carbonator water  
pump inlet fitting. TAPERED GASKET, BLACK (item 7) is used to seal the connection.TUBING CLAMP  
(item 8) is used to secure the plain water source inlet line when connected to the 90° swivel elbow installed  
on the carbonator water pump.  
9
312027000  
SELECTING LOCATION  
CAUTION: This Unit is intended for indoor ins tallation only. Do not ins tall this Unit in an  
outdoor environment which would expos e it to the outs ide elements .  
This Unit may be island-mounted or installed on a front or rear counter. Locate the Unit so the following  
requirements are satisfied:  
DANGER: To avoid pos s ible fatal electrical s hock or s erious injury to the operator, it  
is required that a GFCI (ground fault circuit interrupt) be ins talled in the electrical circuit  
for the domes tic Units . It is required that an ELCB (earth leakage circuit breaker) be  
ins talled in the electrical circuit for the export Units  
1. The Unit must be installed near a properly grounded electrical outlet with proper electrical require-  
ments.The electrical circuit must be properly fused (slow-blow type fuse) or the circuit must be connected  
through an equivalent HACR circuit breaker.The electrical outlet must be accessible for ease of connecting  
and disconnecting the Unit power cord. No other electrical equipment should be connected to this circuit.  
REFER TO UNIT NAMEPLATE FOR THE REQUIRED POWER CIRCUIT OPERATING VOLTAGE, HZ,  
AND THE MINIMUM CIRCUIT AMPACITY OF THE UNIT. ALL ELECTRICAL WIRING MUST CONFORM  
TO NATIONAL AND LOCAL ELECTRICAL CODES.  
CAUTION: Do not place or s tore anything on top of the Unit.  
2. A minimum of 15-inches clearance must be maintained above the Unit to the nearest obstruction (shelf,  
cupboard, ceiling, etc.) and 6-inches clearance between back-side of the Unit and the wall. The front grille  
of the Unit must be unobstructed to allow air to enter the hood.  
3. Close to a permanent drain to route drip tray drain hose and water tank drain hose.  
INSTALLING WATER ONLY LEVER KIT (P/N 3297) ON UF-1 DISPENSING  
VALVE  
The WATER ONLY LEVER KIT, UF-1 DISPENSING VALVE (item 10) is loose-shipped with all six-flavor  
Dispensers equipped with UF-1 dispensing valves. Installation of this kit on the dispensing valve allows plain or  
carbonated (depending on which dispensing valve the kit has been installed on) water only to be dispensed. If  
desired, the kit may be installed at this time following instructions included with the kit.  
INSTALLING UNIT  
NOTE: Optional 4-inch Legs (P/N 314744000) that will elevate the Unit 4-inches above the countertop  
are available. When ordering legs , order a quantity of four.  
CUTTING HOLE IN COUNTERTOP  
Place Unit in location on the countertop flush with the countertop edge. Mark Unit center line on edge of the  
countertop, then move Unit off to one side. Starting at center line mark on edge of the countertop, measure  
back 8-inches for location of the 2-1/2-inch diameter hole to be cut in the countertop. Cut a 2-1/2-inch hole in  
the countertop where indicated. Place the Unit in position over the hole.  
CONNECTING PLAIN WATER SOURCE LINE(S) TO UNIT  
(see applicable Figure 2 or 3 and Figure 4)  
NOTE: IMI Cornelius Inc. recommends that a water s hutoff valve and water filter be ins talled in the  
plain water inlet s upply line (s ee applicable Figure 2 or 3) . A Cornelius Water Filter (P/N 313860000)  
and Quick Dis connect Set (P/N 313867000) are recommended.  
312027000  
10  
DISPENSING VALVE  
RELEASE LATCH  
DISPENSING VALVE  
BLOCK  
SYRUP INLET  
TUBES (6)  
FIGURE 4. SYRUP INLET SUPPLY LINE CONNECTIONS (SIX-FLAVOR UNIT SHOWN)  
11  
312027000  
IMPORTANT: TO THE INSTALLER. It is the res pons ibility of the Ins taller to ens ure that the water s upply  
to the dis pens ing equipment is provided with protection agains t backflow by an air gap as defined in  
ANSI/ASME A112. 1.2-1979; or an approved vacuum breaker or other s uch method as proved effective  
by tes t.  
Water pipe connections and fixtures directly connected to a potable water s upply s hall be s ized,  
ins talled, and maintained according to Federal, State, and Local laws .  
CAUTION: Check the minimum flow rate and maximum pres s ure of plain water inlet s upply  
line. MINIMUM FLOW RATE MUST BE AT LEAST 100-GALLONS PER HOUR. If flow rate is  
les s than 100-gallons per hour, s tarving of carbonator water pump will occur. Starving will  
allow water pump to overheat and will damage the pump. Overheating could occur if plain water  
inlet s upply line flow rate drops below 100-gallons per hour. CARBONATOR CO2 OPERATING  
PRESSURE MUST EXCEED WATER PRESSURE BY 10 PSI. (Example: CO2 operating pres s ure is 80  
ps i, maximum water pres s ure can be no more than 70 ps i, etc.) Water over pres s ure (higher than  
CO2 operating pres s ure) can caus e carbonator flooding, malfunction, and leakage through  
carbonator relief valve. If water is exceeding maximum pres s ure s pecifications , a Water Pres s ure  
Regulator Kit (P/N 317589000) or equivalent mus t be ins talled in plain water inlet s upply line.  
Five and Six-Flavor Units (see applicable Figure 2 or 3)  
1. Route plain water source line from plain water source up to location under the countertop.  
2. Remove Unit front access panel as follows:  
A. Remove drip tray from the Unit.  
B. Remove two screws securing front access panel to the Unit.  
C. Pull front access panel down and out to remove for access to front of the Unit.  
3. Route plain water source line up through hole cut in the countertop, up across front of the Unit, to the car-  
bonator water pump.  
4. Install FITTING, 90° SWIVEL ELBOW (item 9) on end of the plain water source line and secure with  
TUBING CLAMP (item 8).  
5. Connect plain water source line 90° elbow to the carbonator water pump inlet fitting. Seal connection with  
TAPERED GASKET, BLACK (item 7).  
Six-Flavor Units (see Figure 3)  
NOTE: The s ix-flavor (s ee Figure 3) Unit was s et up at the factory to dis pens e a s till (noncarbonated)  
drink from No. 3 dis pens ing valve and carbonated drinks from the remaining dis pens ing valves .  
1. Route plain water source line up to back side of the Unit.  
2. Connect plain water source line to the Unit labeled plain water inlet line protruding out back of the Unit with  
ADAPTOR FITTING (item 4). This water line provides plain water to the Unit No. 3 dispensing valve which  
dispenses a still (non-carbonated) drink.  
CONNECTING SYRUP SOURCE LINES TO UNIT  
(see applicable Figure 2 or 3 and Figure 4)  
NOTE: The Unit s yrup inlet lines are labeled to identify the dis pens ing valves they s erve. For example,  
the line labeled “S1” mus t be connected to the s yrup s ource line that provides s yrup to be dis pens ed  
from the No. 1 dis pens ing valve (No. 1 dis pens ing valve is the valve on the right s ide when facing front  
of the Unit).  
312027000  
12  
1. Route syrup source lines from the syrup tanks location up to location under the countertop.  
2. Route syrup source lines up through hole cut in the countertop to the barbed and labeled syrup inlet lines  
on front of the Unit.  
3. Connect the syrup source lines to the Unit barbed and labeled syrup inlet lines. Secure connections with  
tubing clamps.  
CONNECTING CO SOURCE LINE TO UNIT  
2
(see applicable Figure 2 or 3 and Figure 4)  
1. Route CO2 source line up to back side of the Unit.  
2. Connect CO2 source line to Unit labeled CO2 inlet line. Seal connection with a tapered gasket.  
SEALING UNIT BASE TO COUNTERTOP  
1. To comply with NSF International (NSF) requirements within the United States, the Unit base must be  
sealed to the countertop and all access holes to the Unit base must be completely sealed with a silastic  
sealant such as Dow Corning RTV 731 or equivalent after completing installation of the Unit. Proceed as  
follows to seal the Unit base to the countertop.  
A. Tilt Unit up to expose bottom of the Unit base.  
B. Connect a length of drain hose (not provided), long enough to reach a permanent drain, to drain fitting  
on back side of the drip tray pan. Secure connection with DRAIN HOSE CLAMP (item 6).  
C. Liberally apply silastic sealant such as Dow Corning RTV 731 or equivalent on the Unit base bottom  
edges.  
NOTE: Do not move Unit after pos itioning or s eal from bas e to countertop will be broken.  
D. Route drip tray drain hose down through hole in countertop, then lower Unit into operating position on  
the countertop to complete seal from Unit base to the countertop.  
E. Apply additional sealant around bottom of the base.The seal must have a minimum radius of 1/2-inch  
to prevent crevices and to ensure a complete seal.  
NOTE: Connection of drip tray drain hos e to a permanent drain is recommended. Drip tray drain hos e  
routed to was te container is not recommended due to s anitation and cleaning problems .  
F. Route lower end of drip tray drain hose to and connect to a permanent drain.  
G. Install DRIP TRAY (item 1) in position on the Unit, then place CUP REST (item 2) in the drip tray.  
PREPARING UNIT FOR OPERATION  
FILL WATER TANK AND START REFRIGERATION SYSTEM  
(see Figure 5)  
1. Make sure plug in the water tank drain hose is secure.  
NOTE: Us e low-mineral-content water where a local water problem exis ts .  
2. Remove plug from the drop-in refrigeration assembly platform water fill hole. Fill the water tank with clean  
water until water runs out of the overflow groove on top front of the tank into the drip tray. USE LOW-MIN-  
ERAL-CONTENT WATER WHERE A LOCAL WATER PROBLEM EXISTS. When the water tank is full, the  
water level in the clear plastic water level tube should be approximately one inch from end of the tube.  
13  
312027000  
3. Install plug in water fill hole.  
4. 115 VAC, 60 HZ Units.  
Make sure the main power switch on right side of the Unit (see Figure 5) is in the OFF” position.  
115 VAC, 60 HZ Units and 230 VAC, 50 HZ Units.  
Make sure the carbonator water pump motor power switch located on the drop-in refrigeration assembly  
electrical control box (see Figure 5) is in the OFF” position.  
WARNING: Unit mus t be electrically grounded to avoid pos s ible fatal electrical s hock or  
s erious injury to the operator. Unit power cord is equipped with a three-prong plug. If a  
three-hole (grounded) electrical outlet is not available, us e an approved method to ground  
the Unit.  
5. Plug Unit power cord into a properly grounded electrical outlet.  
6. 115 VAC, 60 HZ Units.  
A. Plug Unit power cord into an accessible and properly grounded electrical outlet with GFCI (ground  
fault circuit interrupt).  
B. Place Unit main power switch on right side of the Unit in the ON” position. The compressor, condens-  
er fan motor, and agitator motor will start and begin forming an ice bank. When full ice bank has been  
formed, the compressor and condenser fan motor will stop but the agitator motor will continue to oper-  
ate circulating ice water bath in the water tank.  
7. 230 VAC, 50 HZ Units.  
A. Plug Unit power cord into an accessible and properly grounded electrical outlet with ELCB (earth  
leakage circuit breaker). The compressor, condenser fan motor, and agitator motor will start and begin  
forming an ice bank. When full ice bank has been formed, the compressor and condenser fan motor  
will stop but the agitator motor will continue to operate circulating ice water bath in the water tank.  
UNIT OPERATION  
WARNING: CO2 dis places oxygen. Strict attention mus t be obs erved in the prevention of  
CO2 (carbon dioxide) gas leaks in the entire CO2 and s oft drink s ys tem. If a CO2 gas leak is  
s us pected, particularly in a s mall area, immediately ventilate the contaminated area before  
attempting to repair the leak. Pers onnel expos ed to high concentration of CO2 gas will experience  
tremors which are followed rapidly by los s of cons cious nes s and s uffocation.  
CAUTION: Before opening CO2 cylinder s hutoff valve, turn s econdary CO2 regulators  
adjus ting s crews to the left (counterclockwis e) until all tens ion is relieved from adjus ting  
s crews s prings .  
1. Open (counterclockwise) the CO2 cylinder shutoff valve slightly to allow the lines to slowly fill with gas, then  
open the valve fully to back-seat the valve. (back-seating the valve prevents leakage around the valve  
shaft). Check for CO2 leaks.  
2. Adjust CO2 regulator (regulator that controls the Unit built-in cold carbonator CO2 pressure) as instructed in  
the SERVICE AND MAINTENANCE section of this manual. Check for CO2 leaks and repair if evident..  
312027000  
14  
3. Open the plain water inlet supply line shutoff valve. Check for water leaks and tighten any loose  
connections.  
4. Place the carbonator water pump motor power switch (located on the refrigeration assembly control box) in  
the ON” position. The carbonator water pump will start and continue to operate until the carbonated water  
tank has been filled, then the water pump motor will stop. Check for CO2, plain water, and carbonated wa-  
ter leaks and tighten any loose connections.  
5. Adjust the syrup tanks CO2 regulators as instructed in SERVICE AND MAINTENANCE section of this  
manual.  
6. Install full syrup tanks into the syrup systems.  
7. Make sure keyed lock-out switch (left-side facing front of Unit) is in the ON” (vertical) position.  
8. Dispense from each dispensing valve until air is bled from the systems and until syrup and applicable plain  
or carbonated water are dispensed.  
9. Check for syrup and water leaks and repair any leaks.  
10. Install the Unit hood and secure with screw.  
ADJ UST WATER-TO-SYRUP “RATIO” (BRIX) OF DISPENSED PRODUCT  
1. Adjust the dispensing valves for water flow rate as instructed in SERVICE AND MAINTENANCE section of  
this manual.  
2. Adjust the dispensing valves for Water-to-Syrup Ratio (Brix) of dispensed product as instructed in  
SERVICE AND MAINTENANCE section of this manual.  
3. Seal all access holes to the Unit with a silastic sealant such as Dow Corning RTV 731 or equivalent.  
4. Install Unit front access panel and secure with two screws.  
5. Install drip tray on the Unit.  
15  
312027000  
THIS PAGE LEFT BLANK INTENTIONALLY  
312027000  
16  
OPERATORS INSTRUCTIONS  
This section covers operating controls, daily pre-operation check, Unit operation, adjustments, replenishing  
CO2 and syrup supplies, cleaning and sanitizing, checking the drop-in refrigeration assembly condenser coil for  
restrictions, checking the ice water bath, water pump yearly maintenance, and periodic cleaning of the CO2 gas  
check valves.  
WARNING: Dis connect electrical power to the Unit to prevent pers onal injury before  
attempting any internal maintenance. Only qualified pers onnel s hould s ervice the internal  
components or electrical wiring.  
CAUTION: Do not place or s tore anything on top of the Unit.  
OPERATING CONTROLS  
(see Figure 5)  
DISPENSING VALVE LEVER  
The dispensing valve lever, located on bottom of the valve, needs only to be pressed with cup or glass to dis-  
pense product.  
DISPENSING VALVE WITH WATER LEVER  
The dispensing valve water lever will dispense only water when actuated.  
DISPENSING VALVES KEYED LOCK-OUT SWITCH  
The dispensing valves keyed lock-out switch, located on the left side of Unit (see Figure 5), must be in the ON”  
(vertical) position to operate the electric dispensing valves. The keyed lock-out switch in the OFF” (horizontal)  
position turns off electrical power to the dispensing valves only, but the refrigeration system will continue to  
operate.  
UNIT POWER SWITCH (115 VAC, 60 H UNITS ONLY)  
Z
The Unit power switch, located on the right side of the Unit (see Figure 5), must be in the ON” position before  
the Unit will operate.  
CARBONATOR WATER PUMP MOTOR POWER SWITCH  
The carbonator water pump motor power switch, located on the refrigeration assembly control box, (see Figure  
5), must be in the ON” position before the carbonator water pump motor will operate. The purpose of the power  
switch is to turn off the carbonator water pump motor for service and maintenance. THE WATER SUPPLY TO  
THE CARBONATOR WATER PUMP MUST BE TURNED ON BEFORE RESTARTING THE CARBONATOR.  
STARVING THE WATER PUMP OF WATER WILL DAMAGE THE PUMP.  
DAILY PRE-OPERATION CHECK  
1. Check CO2 cylinder regulator assembly 1800-psi gage and if the gage indicator is in the shaded (change  
CO2 cylinder) portion of the dial, the CO2 cylinder is almost empty and must be replaced.  
17  
312027000  
2. Make sure there is a sufficient syrup supply. If not, replenish the syrup supply as instructed in SERVICE  
AND MAINTENANCE section in this manual.  
3. Make sure drip tray and cup rest are clean and are properly installed on the Unit.  
UNIT OPERATION  
1. Make sure dispensing valves keyed lock-out switch on left side of the Unit is in the ON” (vertical) position.  
2. Press cup or glass against the dispensing valve lever and dispense until the cup or glass is full of product,  
then release the lever.  
3. If water only is desired, hold cup or glass under the dispensing valve with lever on its side, then actuate  
the lever to dispense water.  
ADJ USTMENTS  
ADJ USTING CO REGULATORS  
2
The CO2 regulators should be checked periodically for proper pressure settings and be adjusted if necessary.  
Refer to SERVICE AND MAINTENANCE section in this manual for adjustment instructions.  
ADJ USTING DISPENSING VALVE WATER FLOW RATE  
The water flow rate of the dispensing valves may be adjusted. Refer to SERVICE AND MAINTENANCE  
section in this manual for adjustment instructions.  
ADJ USTING WATER-TO-SYRUP “RATIO” OF DISPENSED PRODUCT  
The Water-to-Syrup Ratio (Brix) of the dispensed product should be checked periodically and adjusted if  
necessary. Refer to SERVICE AND MAINTENANCE section in this manual for adjustment instructions.  
REPLENISHING CO2 SUPPLY  
WARNING: CO2 dis places oxygen. Strict attention mus t be obs erved in the prevention of  
CO2 (carbon dioxide) gas leaks in the entire CO2 and s oft drink s ys tem. If a CO2 gas leak is  
s us pected, particularly in a s mall area, immediately ventilate the contaminated area before  
attempting to repair the leak. Pers onnel expos ed to high concentration of CO2 gas will experience  
tremors which are followed rapidly by los s of cons cious nes s and s uffocation.  
The CO2 supply should be checked daily and replenished if necessary. Refer to SERVICE AND MAINTE-  
NANCE section in this manual for replenishing procedure.  
REPLENISHING SYRUP SUPPLY  
The syrup supply should be checked daily and replenished if necessary. Refer to SERVICE AND MAINTE-  
NANCE section in this manual for replenishing instructions.  
CLEANING AND SANITIZING  
DAILY CLEANING OF UNIT  
The daily cleaning procedure for the Unit should be performed at the end of the daily operation. Refer to SER-  
VICE AND MAINTENANCE section in this manual for daily cleaning procedure.  
312027000  
18  
SANITIZING SYRUP SYSTEMS  
The syrup systems should be sanitized as instructed every 90-days. Refer to SERVICE AND MAINTENANCE  
section in this manual for sanitizing instructions.  
CHECKING DROP-IN REFRIGERATION ASSEMBLY CONDENSER COIL  
FOR RESTRICTIONS  
NOTE: Circulating air required to cool the refrigeration as s embly condens er coil is drawn in through  
the grille on front and is exhaus ted through grille on top of the hood. Res tricting air in or out of the  
Unit will decreas e its cooling efficiency.  
Area on top of the hood must be kept free of obstructions at all times. Make sure nothing is stored on top of the  
hood. The refrigeration assembly condenser coil should be periodically cleaned to maintain cooling efficiency as  
instructed in the SERVICE AND MAINTENANCE section of this manual.  
CHECKING ICE WATER BATH  
A gurgle” heard from the Unit indicates the water level in the water tank is low and more water should be added  
for maximum product cooling. The water adding procedure may be found in the SERVICE AND MAINTE-  
NANCE section of this manual.  
CARBONATOR WATER PUMP YEARLY MAINTENANCE OR AFTER WATER  
SYSTEM DISRUPTIONS  
The water pump water strainer screen and the double-liquid check valve must be inspected and cleaned as  
instructed at least once a year under normal circumstances and after any water system disruption (plumbing  
work, earthquake, etc.). Refer to SERVICE AND MAINTENANCE section of this manual for inspecting and  
cleaning procedure.  
CLEANING CO2 GAS CHECK VALVES  
The CO2 gas check valves must be inspected and serviced as instructed at least once a year under normal  
conditions and after any CO2 system servicing or disruption. Servicing of the CO2 gas check valves should be  
performed by qualified Service Person. Refer to SERVICE AND MAINTENANCE section in this manual for  
inspecting and servicing procedures.  
19  
312027000  
THIS PAGE LEFT BLANK INTENTIONALLY  
312027000  
20  
SERVICE AND MAINTENANCE  
This section describes service and maintenance procedures to be performed on the Unit.  
IMPORTANT: Only qualified pers onnel s hould s ervice internal components or electrical wiring.  
WARNING: Dis connect electrical power to the Unit to prevent pers onal injury before  
attempting any internal maintenance. Only qualified pers onnel s hould s ervice the internal  
components or electrical wiring.  
PREPARING UNIT FOR SHIPPING, STORING, OR RELOCATING  
CAUTION: Before s hipping, s toring, or relocating this Unit, the s yrup s ys tems mus t be  
s anitized and all s anitizing s olution mus t be purged from the s yrup s ys tems . All water mus t  
als o be purged from the plain and carbonated water s ys tems . A freezing ambient  
environment will caus e res idual water in the Unit to freeze res ulting in damage to internal  
components .  
HOOD AND FRONT PANEL REMOVAL  
(see Figure 5)  
HOOD REMOVAL  
CAUTION: Do not place or s tore anything on top of the Unit.  
Loosen screw on top of hood, then lift hood straight up and off Unit.  
FRONT ACCESS PANEL REMOVAL  
1. Remove drip tray from the Unit.  
2. Remove two screws securing the front access panel to the Unit.  
3. Pull the front access panel down and out to remove.  
PERIODIC INSPECTION  
1. Check the refrigeration condenser coil for obstructions and dirt. DO NOT place objects in front of or on top  
of the hood. Restricting circulating air in or out of the Unit will decrease its cooling efficiency.  
2. Check the dispensing valves for dripping that indicates leaking and repair as necessary.  
ADJ USTMENTS  
ADJ USTING CO REGULATORS  
2
WARNING: CO2 dis places oxygen. Strict attention mus t be obs erved in the prevention of  
CO2 (carbon dioxide) gas leaks in the entire CO2 and s oft drink s ys tem. If a CO2 gas leak is  
s us pected, particularly in a s mall area, immediately ventilate the contaminated area before  
attempting to repair the leak. Pers onnel expos ed to high concentration of CO2 gas will experience  
tremors which are followed rapidly by los s of cons cious nes s and s uffocation.  
312027000  
21  
AGITATOR MOTOR  
HOOD RETAINING  
SCREW (1)  
COMPRESSOR  
CONDENSER FAN  
MOTOR  
BUILT-IN COLD  
CARBONATOR  
POWER CORD  
CONDENSER COIL  
CONTROL  
BOX  
WATER FILL  
HOLE PLUG  
DISPENSING VALVES  
KEYED-LOCK SWITCH  
DISPENSING VALVE  
SYRUP FLOW  
REGULATOR  
DISPENSING VALVE  
LEVER  
DISPENSING VALVE  
COVER WITH  
WATER LEVER  
CUP REST  
FRONT PANEL  
WATER PUMP  
MOTOR  
WATER PUMP  
SHIPPING NUT (4)  
MAIN POWER SWITCH  
(115VAC UNIT ONLY)  
DRIP TRAY  
DISPENSING VALVE  
RELEASE LATCH  
MOUNTING BLOCK  
FIGURE 5. DISPENSER COMPONENTS  
312027000  
22  
NOTE: To readjus t CO2 regulator to a lower s etting, loos en adjus ting s crew lock nut, then turn s crew to  
the left (counterclockwis e) until pres s ure gage reads 5 ps i lower than new s etting will be. Turn the ad-  
jus ting s crew to the right (clockwis e) until the gage regis ters new s etting, then tighten the lock nut.  
Adjusting Carbonator CO2 Regulator.  
Adjust primary CO2 regulator (regulator controls Unit built-in cold carbonator CO2 pressure) to a nominal 80  
psig. Check for CO2 leaks and repair if evident. INLET CO2 PRESSURE TO CARBONATOR MUST NOT  
EXCEED 125 PSIG.  
Sugar Syrup Tanks Secondary CO2 Regulator.  
Adjust sugar syrup tanks secondary CO2 regulator with 100 psi gage at 40 psig for syrup lines up to 10 feet in  
length plus one pound for each additional length of 10 feet, plus one pound for each 2 feet of vertical lift. For  
example; if syrup line total length is 30 feet and total vertical lift is 6 feet, then 40 psig + 2 psig (1-pound for ev-  
ery 10 feet of length over 10 feet which is 20 feet) + 3 psig (1 pound for every 2 feet of vertical lift which is 6  
feet); total equals 40 + 2 + 3 = 45 psig CO2 regulator setting. Loosen lock nut on CO2 regulator adjusting screw,  
turn adjusting screw to the right (clockwise) until gage registers desired pressure, then tighten lock nut.  
Low-Calorie (Diet) Syrup Tank Secondary CO2 Regulator  
Adjust low-calorie (diet) soft drink tank secondary CO2 regulator with 30 psi gage to 10 psig for syrup lines up to  
30 feet in length. Syrup lines longer than 30 feet in length may require a slightly higher CO2 regulator setting of  
12 psig maximum. Excessive CO2 pressure may cause low-calorie syrup carbonation resulting in foam.  
ADJ USTING DISPENSING VALVES WATER FLOW RATE  
SF-1 Dispensing Valve.  
(see Figure 6)  
1. Remove acorn nut securing the dispensing valve cover, then remove the cover to expose the valve water  
and the syrup flow controls.  
2. Remove dispensing valve nozzle by turning nozzle counterclockwise and pulling down.  
3. Remove syrup diffuser by pulling straight down.  
ADJ USTABLE WATER  
ADJ USTABLE SYRUP  
FLOW REGULATOR  
FLOW REGULATOR  
NOZZLE  
SYRUP DIVERSION  
TUBE ASSY  
(P/N 319540000)  
WATER  
CHAMBER  
RATIO CUP  
(P/N 311100000)  
FIGURE 6. SF-1 DISPENSING VALVE  
312027000  
23  
4. Install syrup separator on dispensing valve in place of the nozzle.  
5. Measure the water flow rate by dispensing water into a graduated cup for a set period of time. Factory-set  
flow rate is approximately 1.25 ounces per second.  
6. Adjust the water flow control adjusting screw clockwise for a greater flow or counterclockwise for lesser  
flow. Limit your adjustment to 1/4 turn at a time, then recheck the flow rate. Only the water flow rate is to  
be adjusted now. Syrup flow rate is adjusted in the Water-to Syrup Ratio (Brix) Adjustment section.  
UF-1 Dispensing Valve  
(see Figure 7)  
1. Remove cover from the dispensing valve by lifting the front cover up 1/4 inch and pulling forward.  
2. Install syrup diversion tube assembly on the dispensing valve by pushing rubber end of the syrup diversion  
tube onto the syrup outlet of the inner nozzle.  
3. Measure the water flow rate by dispensing water into a graduated cup for a set period of time.  
NOTE: Adjus ting s crew s tops are built into the valve to prevent leakage when the s crews are adjus ted  
too far clockwis e. Stop adjus ting clockwis e when turning res is tance increas es . Turn the s crew coun-  
terclockwis e 1--1/2 turns after the s top are contacted.  
4. Turn the water flow regulator adjusting screw to the left (counterclockwise) to decrease the water flow rate  
or turn the adjusting screw to the right (clockwise) to increase the water flow rate, then recheck the flow  
rate. Adjustments should be no more than 1/4 turn at a time.  
5. Remove syrup diversion tube from the dispensing valve, then install cover on the dispensing valve.  
WATER FLOW  
REGULATOR  
SYRUP FLOW  
REGULATOR  
INNER NOZZLE  
Counterclockwis e  
NOZZLE  
to Decreas e  
SYRUP DIVERSION  
Clockwis e  
to Increas e  
TUBE  
RATIO CUP  
FIGURE 7. UF-1 DISPENSING VALVE  
24  
312027000  
ADJ USTING WATER-TO-SYRUP “RATIO” (BRIX) OF DISPENSED PRODUCT  
SF-1 Dispensing Valve.  
(see Figure 6)  
NOTE: Make s ure the dis pens ing valve water flow rate is as des ired before adjus ting the valve for Wa-  
ter-to-Syrup Ratio (Brix) of the dis pens ed product.  
Adjust Water-to-Syrup Ratioof dispensed product by using Ratio Cup (P/N 311100000) and Syrup Diversion  
Tube Assembly (P/N 319540000) as follows.  
1. Remove acorn nut securing the dispensing valve cover, then remove cover from the valve.  
2. Install the syrup diversion tube assembly on the dispensing valve by pushing the rubber end of the syrup  
diversion tube up on the baffle inside the nozzle.  
NOTE: Refer to s yrup manufacturers recommendations on s yrup package for Water-to-Syrup Ratio’.  
3. Hold container under the dispensing valve. Open the dispensing valve and dispense just enough to fill the  
syrup diversion tube with syrup.  
4. Hold large chamber of the ratio cup under the dispensing valve nozzle. Place free end of the syrup diver-  
sion tube into syrup chamber marked for proper ratio. Open the dispensing valve and dispense approxi-  
mately five ounces of water into the ratio cup. Water and syrup levels should be even in the ratio cup.  
5. Adjusting Syrup Flow Regulator. If water and syrup levels are not even in ratio cup, turn dispensing valve  
syrup flow regulator labeled SYRUPadjusting screw to the left (counterclockwise) no more than 1/4-turn  
at a time for less syrup or to the right (clockwise) no more than 1/4-turn at a time for more syrup.  
6. Repeat Water-to-Syrup Ratio test and adjust the syrup flow regulator as many times as necessary until  
proper ratio of the dispensed drink is achieved.  
7. Remove syrup diversion tube assembly from the dispensing valve.  
8. Install the dispensing valve cover and secure with acorn nut.  
UF-1 Dispensing Valve  
(see Figure 7)  
NOTE: Make s ure the dis pens ing valve water flow rate is as des ired before adjus ting the valve for Wa-  
ter-to-Syrup Ratio (Brix) of the dis pens ed product.  
Adjust Water--to--Syrup Ratio” (Brix) of the dispensed product by using ratio cup (P/N 311100000) and syrup  
diversion tube assembly (P/N 319540000) as follows:  
1. Remove cover from the dispensing valve by lifting front cover up 1/4 inch and pulling forward.  
2. Install syrup diversion tube assembly on the dispensing valve by pushing the rubber end of the syrup diver-  
sion tube onto the syrup outlet of the inner nozzle.  
Notice: Refer to s yrup manufacturers recommendations on s yrup package for water-to-s yrup ratio.  
3. Dispense enough to fill syrup diversion tube with syrup.  
4. Hold large chamber of the ratio cup under the dispensing valve nozzle. Place free end of the syrup diver-  
sion tube into the syrup chamber marked for the proper ratio. Dispense approximately 6 ounces of water  
into the ratio cup. Water and syrup levels should be even in cup.  
Note: Adjus ting s crew s tops are built into the valve to prevent leakage when the s crews are adjus ted  
clockwis e too much. Stop adjus ting clockwis e when turning res is tance increas es . Turn the s crew  
counterclockwis e 1--1/2 turns after the s top are contacted.  
312027000  
25  
5. Adjus ting Syrup Flow Regulator -- If water and syrup levels are uneven in the ratio cup, adjust by  
turning the dispensing valve syrup flow regulator adjusting screw labeled SYRUP as follows.  
A. For less syrup, turn the adjusting screw counterclockwise no more than 1/4 turn at a time.  
B. For more syrup, turn the adjusting screw clockwise no more than 1/4 turn at a time.  
6. Repeat water-to-syrup ratio test and adjust syrup flow regulator as many times as necessary until proper  
ratio of dispensed drink is achieved.  
7. Remove syrup diversion tube assembly from dispensing valve.  
8. Install dispensing valve front cover.  
CLEANING DROP-IN REFRIGERATION ASSEMBLY CONDENSER COIL  
(see Figure 5)  
Excessive accumulation of dust, lint, and grease on the drop-in refrigeration assembly condenser coil will restrict  
air flow through the coil and cause a loss of cooling. Perform the following procedure to clean the condenser  
coil.  
1. Unplug Unit power cord from electrical outlet.  
2. Remove hood by loosening screw on top of the hood, then lift the hood straight up off the Unit.  
3. Vacuum or use a soft brush to clean the condenser coil. If available, use compressed air to blow dust and  
debris out of the condenser coil.  
4. Clean dust and dirt from around top of the refrigeration assembly.  
5. Install hood on the Unit and secure with one screw.  
6. Plug Unit power cord into electrical outlet.  
CHECKING ICE WATER BATH  
(see Figure 5)  
A gurgle” heard from the Unit indicates water level in the water tank is low and more water should be added to  
the tank for maximum cooling. Before adding more water, ice water bath and ice bank should be checked for  
cleanliness and the water tank coils checked for excessive mineral deposit build-up.  
1. Unplug Unit power cord from electrical outlet.  
2. Remove Unit hood by loosening one screw on top of the hood, then lift the hood straight up off the Unit.  
3. Remove plug from the drop-in refrigeration assembly platform water fill hole.  
4. Using a flashlight, inspect the ice water bath and the ice bank for cleanliness. The ice water bath should be  
clear and the ice bank should be free of foreign particles.  
5. If cleaning of the water tank is necessary, refer to CLEANING WATER TANK in this section.  
6. Fill the water tank with clean water until water runs out of the overflow groove on top front of the tank into  
the drip tray. USE LOW-MINERAL-CONTENT WATER WHERE A LOCAL WATER PROBLEM EXISTS  
When the water tank is full, the water level in the clear plastic water level tube should be approximately one  
inch from end of the tube.  
7. Install plug in the water fill hole.  
8. Install the Unit hood and secure with screw.  
9. Plug Unit power cord into electrical outlet.  
312027000  
26  
CLEANING WATER TANK  
(see Figure 5 and 8)  
1. Unplug Unit power cord from electrical outlet.  
2. Shut off plain water supply to the Unit.  
3. Note pressure setting on the primary CO2 regulator for the carbonator, then turn the regulator adjusting  
screw to the left (counterclockwise) until gage reads 0-psig.  
4. Remove the Unit hood by loosening screw on top of the hood, then lift the hood straight up off the Unit.  
5. Disconnect the drop-in refrigeration assembly power cord from the Unit power cord.  
6. Disconnect the dispensing valves power cord from the drop-in refrigeration assembly mating power cord.  
7. Disconnect the carbonated water tank sensor leads power cord from the drop-in refrigeration assembly  
mating power cord.  
8. Remove screw securing the carbonated water tank access hole cover, then remove the cover for access to  
the carbonated water tank relief valve.  
9. Pull up on the carbonated water tank relief valve to release CO2 gas pressure from the tank and the car-  
bonated water system.  
10. Disconnect the plain water inlet and the carbonated water outlet lines from the carbonator water pump.  
11. Remove four hex nuts securing the drop-in refrigeration assembly in the Unit lower housing.  
12. Very carefully, lift the drop-in refrigeration assembly up and out of the Unit lower housing.  
CAUTION: Never us e an ice pick or other ins trument to remove ice from the drop-in  
refrigeration as s embly evaporator coils . Such practice can res ult in a punctured  
refrigeration circuit.  
13. Allow ice bank to melt. Hot water may be used to speed melting.  
14. Use a fiber brush and carefully clean mineral deposit build-up from the agitator motor shaft and the ice  
bank sensing bulb.  
15. Route the water tank drain hose to a drain. Remove plug from end of the drain hose and allow the water  
tank to drain.  
16. Wash inside of the water tank and the drop-in refrigeration assembly evaporator coils, then rinse with clean  
water.  
17. Install plug in end of the water tank drain hose.  
18. Install the drop-in refrigeration assembly in the Unit by reversing the removal procedure.  
19. Remove plug from the drop-in refrigeration assembly platform water fill hole.  
20. Fill the water tank with clean water until water runs out of the overflow groove on top front of the tank into  
the drip tray. USE LOW-MINERAL-CONTENT WATER WHERE A LOCAL WATER PROBLEM EXISTS  
When the water tank is full, the water level in the clear plastic water level tube should be approximately one  
inch from end of the tube.  
21. Install plug in the drop-in refrigeration assembly platform water fill hole.  
22. Turn the primary CO2 regulator adjusting screw to the right (clockwise) until the gage indicates pressure  
setting noted in step 3 preceding.  
23. Restore plain water supply to the Unit. Check for CO2 and water leaks and repair if evident.  
312027000  
27  
24. Plug Unit power cord into electrical outlet.  
25. Dispense from one of the carbonated drink dispensing valves to bleed all air from the Unit carbonated  
water tank and the carbonated water system.  
26. Check for leaks and repair if evident.  
27. Install hood and secure with screw.  
CARBONATOR  
SENSOR LEADS  
CARBONATOR  
TANK  
RELIEF  
VALVE  
FIGURE 8. WATER TANK  
CLEANING AND SANITIZING  
DAILY CLEANING OF UNIT  
1. Remove cup rest from the drip tray.  
2. Wash drip tray in place on the Unit, then rinse drip tray with hot water allowing water to drain out through  
the drain hose.  
3. Wash cup rest, then rinse the cup rest with clean water. Install cup rest in the drip tray.  
4. Clean all external surfaces of the Unit with a sponge. Rinse out the sponge with clean water, then wring  
excess water out of the sponge and wipe off all external surfaces on the Unit. Wipe Unit dry with a clean  
soft cloth. DO NOT USE ABRASIVE CLEANERS.  
312027000  
28  
5. Remove nozzle and syrup diffusers from the dispensing valves. Place nozzles and syrup diffusers in sani-  
tizing solution.  
6. Wash the nozzles and syrup diffusers in sanitizing solution, then rinse them with potable water.  
7. Re-install nozzles and syrup diffusers back on the dispensing valves.  
SANITIZING POST-MIX SYRUP SYSTEMS  
IMPORTANT: Only qualified Service Pers onnel s hould perform s anitizing procedure on the pos t-mix  
s yrup s ys tems .  
The post-mix syrup systems should be sanitized every 90-days using a non-scented household liquid bleach  
containing a 5.25 % sodium hypochlorite concentration. Proceed as follows to sanitize the post-mix syrup sys-  
tems.  
1. Disconnect syrup supplies from syrup systems.  
2. Rinse quick disconnects (syrup tanks systems) or bag-in-box connectors (syrup bag-in-box systems) in  
warm potable water.  
STEP 1. WASH SYRUP SYSTEMS  
3. Using a clean syrup tank (syrup tank system) or a five-gallon container (bag-in-box system), prepare a full  
tank or container of liquid dishwasher detergent by using 70_ F (21_ C) to 100_ F (38_ C) potable water  
and 0.5 oz. (15 ml) of liquid dishwasher detergent to one gallon of potable water. Stir detergent solution to  
thoroughly mix the solution.  
4. Syrup Tank Systems.  
A. Observe and note CO2 pressure setting on the syrup tanks CO2 regulator, then re-adjust CO2 regula-  
tor to 60 to 80-psi. Pressurize syrup tank containing detergent solution to 60 to 80-psi.  
B. Connect detergent solution tank, pressurized at 60 to 80-psi, into one of the syrup systems.  
Bag-in Box Syrup Systems.  
C. Install bag valves, cut from empty bag-in-box syrup containers, on ends of syrup containers syrup  
outlet tubes connectors.  
D. Place all syrup outlet tubes, with bag valves on their ends, in container containing detergent solution.  
5. Flush the syrup system and dispensing valve as follows:  
A. Place waste container under applicable dispensing valve.  
B. Activate the dispensing valve for one minute to purge all syrup and flush out the syrup system.  
C. Continue to activate the dispensing valve in cycles (ON” for 15-seconds, OFF, then ON” for  
15-seconds). Repeat ON” and OFF” cycles for 15-cycles.  
6. Connect detergent solution to the remaining syrup systems and flush syrup out of the syrup systems as  
instructed in step 5 preceding.  
7. Remove detergent solution source from the syrup system.  
STEP 2. FLUSH SYRUP SYSTEMS  
8. Syrup Tank Systems.  
Connect syrup tank containing potable water, pressurized at 60 to 80-psi, into one of the syrup systems.  
Bag-in-Box Syrup System.  
312027000  
29  
Fill five-gallon container with potable water, then place all bag-in-box syrup containers syrup outlet tubes in  
container containing potable water.  
9. Flush detergent solution out of the syrup system and dispensing valve as follows:  
A. Place waste container under applicable dispensing valve.  
B. Activate the dispensing valve for one minute to purge all detergent solution and flush out the syrup  
system.  
C. Continue to activate the dispensing valve in cycles (ON” for 15-seconds, OFF, then ON” for  
15-seconds). Repeat ON” and OFF” cycles for 15-cycles.  
10. Connect potable water source to the remaining syrup systems and flush detergent solution out of the syrup  
systems as instructed in step 9 preceding.  
11. Remove potable water source from the syrup system.  
STEP 3. SANITIZE SYRUP SYSTEMS  
12. Using a clean syrup tank (syrup tanks system) or a five-gallon container (bag-in-box system), prepare sani-  
tizing solution using 70_ F (21_ C) to100_ F (38_ C) potable water and 0.5 oz. (15 ml) of non-scented  
household liquid bleach that contains a 5.25 % sodium hypochlorite concentration to one gallon of potable  
water. This mixture must not exceed 200 PPM of chlorine. Stir sanitizing solution to thoroughly mix.  
13. Syrup Tank Systems.  
Connect sanitizing solution tank, pressurized at 60 to 80-psi, into one of the syrup systems.  
Bag-in-Box Syrup System.  
Place all bag-in-box syrup containers syrup outlet tubes in container containing sanitizing solution.  
14. Sanitize the syrup system and dispensing valve as follows:  
A. Place waste container under applicable dispensing valve.  
B. Activate the dispensing valve for one minute to purge all water from and install sanitizing solution in  
the syrup system and dispensing valve.  
C. Continue to activate the dispensing valve in cycles (ON” for 15-seconds, OFF, then ON” for  
15-seconds). Repeat ON” and OFF” cycles for 15-cycles.  
15. Repeat steps13 and 14 to flush water out of and install sanitizing solution in the remaining syrup systems  
and dispensing valves.  
16. Remove sanitizing solution source from the syrup system.  
17. Allow sanitizing solution to remain in the syrup systems for not less than 10 or no more than 15-minutes  
(max.) contact time.  
STEP 4. WATER FLUSH SYRUP SYSTEMS  
WARNING: Flus h s anitizing s olution from the s yrup s ys tems as ins tructed. Res idual  
s anitizing s olution left in the s yrup s ys tems could create a health hazard.  
18. Fill syrup tank (syrup tank system) or a five-gallon container (bag-in-box system) with potable water.  
19. Syrup Tank Systems.  
Connect syrup tank containing potable water, pressurized at 60 to 80-psi, into one of the syrup systems.  
Bag-in-Box Syrup System.  
312027000  
30  
Place all bag-in-box syrup containers syrup outlet tubes in container containing potable water.  
20. Flush sanitizing solution from the syrup system and the dispensing valve as follows:  
A. Place waste container under applicable dispensing valve.  
B. Activate the dispensing valve for one minute to purge all sanitizing solution out of the syrup system  
and the dispensing valve.  
C. Continue to activate the dispensing valve in cycles (ON” for 15-seconds, OFF, then ON” for  
15-seconds). Repeat ON” and OFF” cycles for 15-cycles.  
21. Repeat steps 19 and 20 preceding to purge sanitizing solution out of the remaining syrup systems and  
dispensing valves.  
22. Remove potable water source from the syrup system.  
STEP 5. PURGE WATER OUT OF SYRUP SYSTEMS (RESTORE OPERATION)  
23. Syrup Tank Systems.  
A. Noting syrup tanks CO2 regulator pressure setting observed in step 4 preceding, readjust CO2 regula-  
tor to the observed pressure setting,  
B. Connect tanks containing syrup into syrup systems.  
Bag-in-Box Syrup System.  
C. Remove all bag valves from bag-in-box syrup containers outlet tubes connectors.  
D. Connect bag-in-box syrup containers into the syrup systems.  
24. Place waste container under dispensing valves. Dispense from all dispensing valves to permit syrup to  
purge all potable water from the syrup systems and the dispensing valves. Continue to dispense from the  
dispensing valves until only syrup is dispensed from the syrup systems and valves.  
WARNING: To avoid pos s ible pers onal injury or property damage, do not attempt to  
remove the s yrup tank cover until CO2 pres s ure has been releas ed from the tank.  
25. Dispose of waste sanitizing solution in a sanitary sewer, not in a storm drain, then thoroughly rinse the in-  
side and the outside of the container that was used for sanitizing solution to remove all sanitizing solution  
residue.  
CARBONATOR WATER PUMP YEARLY MAINTENANCE OR AFTER WATER  
SYSTEM DISRUPTIONS  
WARNING: The carbonator water pump water inlet s trainer s creen and the double-liquid  
check valve mus t be ins pected and cleaned at leas t once a year under normal  
circums tances , and after any dis ruptions (plumbing work, earthquake, etc.) to the water  
s upply s ys tem that might caus e turbulent (erratic) flow of water through the s ys tem. A carbonator  
water pump with no s creen or a defective s creen in the s trainer would allow foreign particles to  
foul the double-liquid check valve. CO2 gas could then back flow into the water s ys tem and create  
a health hazard.  
The carbonator water pump water inlet strainer screen and the double-liquid check valve must be inspected and  
cleaned at least once a year under normal circumstances and after any water system disruption (plumbing  
work, earthquake, etc.) as follows:  
312027000  
31  
Servicing Water Pump Water Inlet Strainer Screen  
(see Figures 5 and 9)  
1. Unplug Unit power cord from electrical outlet.  
2. Remove the Unit hood by loosening one screw on top of the hood, then lift the hood up and off the Unit.  
3. Close the water inlet supply line shutoff valve.  
4. Note pressure setting on the carbonator primary CO2 regulator, then turn the regulator adjusting screw to  
the left (counterclockwise) until the gage reads 0-psig.  
5. Remove screw securing the carbonated water tank access hole cover, then remove the cover for access to  
the carbonated water tank relief valve.  
6. Pull up on the carbonated water tank relief valve to release CO2 gas pressure from the tank and the car-  
bonated water system.  
7. Loosen the screen retainer, then pull the screen retainer and the strainer screen from the water pump.  
8. Pull the screen from the screen retainer. Clean any sediment from the screen retainer and the water pump  
screen retainer port.  
9. Inspect the screen for holes, restrictions, corrosion, and other damage. Replace the screen if damaged  
(P/N 315348000).  
10. Check O-Ring on the screen retainer. Replace the worn or damaged O-Ring (P/N 315349000).  
NOTE: A s creen s hould always be us ed, otherwis e particles could foul the double-liquid check valve.  
11. Install screen (P/N 315348000) in the screen retainer, then screw the retainer into the water pump and  
tighten securely.  
12. Service the double-liquid check valve, (refer to next paragraph Servicing Double-Liquid Check Valve) as  
instructed.  
Servicing Double-Liquid Check Valve.  
(see Figures 5, 9, and 10)  
1. Service the water inlet strainer screen as instructed in previous paragraph before servicing the double-liq-  
uid check valve.  
2. Disconnect the carbonated water line from the double-liquid check valve, then remove the double-check  
valve from the water pump outlet port.  
3. Disassemble each check valve as shown in Figure 10.  
4. Wipe each part with a clean lint-free cloth. Inspect each part, especially the ball for burrs, nicks, corrosion,  
deterioration, and other damage. Discard the ball seat and any damaged or suspicious parts and replace  
with new parts during reassembly.  
5. Reassemble check valves as shown in Figure 10. ALWAYS INSTALL A NEW BALL SEAT (QUAD RING)  
P/N 312418000.  
NOTE: Make s ure when as s embling the check valves together, the check valve female end with a white  
tapered gas ket ins ide is on the inlet s ide of the double-liquid check valve as s embly.  
6. Assemble the check valves together as shown in Figure 10.  
7. Install the double-liquid check valve in the water pump outlet port.  
312027000  
32  
WATER LINE TO TANK  
WHITE TAPERED GASKET  
DOUBLE-LIQUID  
CHECK VALVE  
ELBOW  
PUMP TO MOTOR COUPLING  
WATER PUMP  
WATER  
STRAINER SCREEN  
(P/N 315348000)  
O-RING (P/N 315349000)  
SCREEN RETAINER  
FIGURE 9. WATER STRAINER SCREEN AND DOUBLE-LIQUID CHECK VALVE  
8. Connect the carbonated water line to the double-liquid check valve.  
9. Turn the carbonator primary CO2 regulator adjusting screw to the right (clockwise) until its gage indicates  
pressure setting noted in step 4 of Servicing Water Pump Water Inlet Strainer Screen.  
10. Open the water inlet supply line shutoff valve.  
11. Pull up on the carbonated water tank relief valve to purge all air from the tank.  
12. Install the carbonated water tank access hole cover and secure with screw.  
13. Install the Unit hood and secure with screw.  
14. Plug Unit power cord into electrical outlet.  
15. Test dispense Unit for proper operation.  
REPLENISHING CO2 SUPPLY  
WARNING: CO2 dis places oxygen. Strict attention mus t be obs erved in the prevention of  
CO2 (carbon dioxide) gas leaks in the entire CO2 and s oft drink s ys tem. If a CO2 gas leak is  
s us pected, particularly in a s mall area, immediately ventilate the contaminated area before  
attempting to repair the leak. Pers onnel expos ed to high concentration of CO2 gas will experience  
tremors which are followed rapidly by los s of cons cious nes s and s uffocation.  
312027000  
33  
4
3
1
4
3
2
1
2
Item  
No.  
Part No.  
5470E  
Name  
1
2
3
4
Flat Washer  
312418000  
312419000  
5470D  
Ball Seat (Quad Ring)  
Ball  
Spring  
FIGURE 10. LIQUID CHECK VALVE ASSEMBLY  
NOTE: When indicator on the CO2 cylinder primary CO2 regulator as s embly 1800-ps i gage is in the  
s haded (change CO2 cylinder’) portion of the dial, the CO2 cylinder is almos t empty and s hould be  
changed.  
1. Fully close (clockwise) the CO2 cylinder main shutoff valve.  
2. Slowly loosen primary the CO2 regulator assembly coupling nut allowing CO2 pressure to escape, then  
remove the regulator assembly from the empty CO2 cylinder.  
3. Unfasten safety chain and remove the empty CO2 cylinder.  
WARNING: To avoid pers onal injury and/or property damage, always s ecure the CO2  
cylinder in an upright pos ition with a s afety chain to prevent it from falling over. Should the  
valve become accidentally damaged or broken off, the CO2 cylinder can caus e s erious  
pers onal injury.  
4. Position full CO2 cylinder in an upright position and secure with a safety chain.  
5. Make sure a gasket is in place inside the primary CO2 regulator coupling nut, then install regulator on the  
CO2 cylinder.  
6. Open (counterclockwise) the CO2 cylinder main shutoff valve slightly to allow the lines to slowly fill with  
gas, then open the valve fully to back-seat the valve. (Back-seating the valve prevents leakage around the  
valve shaft).  
7. Check all CO2 connections for leaks. Tighten any loose connections and repair any leaks.  
REPLENISHING SYRUP SUPPLY  
NOTE: The following ins tructions are applicable only when replenis hing s ame flavor s yrup. Refer to  
SYRUP FLAVOR CHANGE when changing s yrup flavor.  
312027000  
34  
SYRUP TANK SYSTEM  
1. Disconnect empty syrup tank from syrup system.  
2. Check syrup drink quick disconnects for sticky or restricted operation. Wash disconnects in warm water.  
3. Connect full tank of syrup into syrup system.  
BAG-IN-BOX SYRUP SYSTEM  
1. Disconnect empty bag-in-box container from syrup system.  
2. Check bag-in-box connecter for sticky or restricted operation. Wash bag-in-box connecter in warm water.  
3. Connect full bag-in-box container into syrup system.  
SYRUP FLAVOR CHANGE  
1. Perform sanitizing procedure (as instructed in this section of the manual) on the syrup system syrup flavor  
change will be made on.  
2. Connect a new flavor syrup into the syrup system.  
CLEANING CO2 SYSTEM CO2 GAS CHECK VALVES  
(see applicable Figure 2 or 3 and 11)  
The CO2 regulators and CO2 manifold CO2 gas check valves must be inspected and serviced at least once a  
year under normal conditions and after any servicing or disruption of the CO2 system. ALWAYS REPLACE  
BALL SEAT (QUAD RING SEAL) EACH TIME GAS CHECK VALVES ARE SERVICED.  
FIGURE 11. CO2 GAS CHECK VALVE ASSEMBLY  
312027000  
35  
THE GERMAN ICE BANK CONTROL IS FOR  
INTERNATIONAL USE ONLY.  
FIGURE 12. WIRING SCHEMATIC FOR ELECTRONIC ICE BANK CONTROL (OPTIONAL)  
312027000  
36  
312027000  
37  
312027000  
38  
312027000  
39  
SOLENOID  
FRONT  
TOP VIEW  
BLACK  
1
2
BLACK  
SWITCH  
C
N.O.  
N.C.  
RIGHT SIDE VIEW  
FIGURE 16. WIRING DIAGRAM (SF-1 DISPENSING VALVE)  
SOLENOID  
WHITE  
TWO - PIN  
CONNECTOR  
2
BLACK  
1
RED  
P/N 1933  
C
NO  
SWITCH ASSY  
P/N 1932  
LEVER  
P/N 1925  
FIGURE 17. WIRING DIAGRAM (UF-1 DISPENSING VALVE)  
312027000  
40  
THIS PAGE LEFT BLANK INTENTIONALLY  
312027000  
41  
TROUBLESHOOTING  
IMPORTANT: Only qualified pers onnel s hould s ervice internal components or electrical wiring.  
WARNING: If repairs are to be made to a product s ys tem, remove quick dis connects from  
the applicable product tank, then relieve the s ys tem pres s ure before proceeding. If repairs  
are to be made to the CO2 s ys tem, s top dis pens ing, s hut off the CO2 s upply, then relieve the  
s ys tem pres s ure before proceeding. If repairs are to be made to the refrigeration s ys tem, make s ure  
electrical power is dis connected from the unit.  
TROUBLESHOOTING POST-MIX SYSTEM SYSTEM  
Trouble  
Probable Cause  
Remedy  
WATER-TO-SYRUP RATIO”  
TOO LOW OR TOO HIGH  
A. Dispensing valve syrup flow  
control not properly adjusted.  
A. Adjust Water-to-Syrup Ratio as  
instructed.  
B. Syrup Tanks Sys tem.  
CO2 gas pressure to syrup  
tanks insufficient to push syrup  
out of tanks.  
B. Adjust CO2 regulator for syrup  
tanks as instructed.  
Bag-in-Box Syrup Sys tem.  
CO2 gas pressure to syrup  
pumps insufficient to operate  
pumps.  
Adjust CO2 regulator for syrup  
pumps as instructed.  
ADJUSTMENT OF  
A. No syrup supply.  
A. Replenish syrup supply as  
instructed.  
DISPENSING VALVE SYRUP  
FLOW CONTROL DOES NOT  
INCREASE TO DESIRED  
WATER-TO-SYRUP RATIO.  
B. Syrup Tanks Sys tem.  
Syrup tanks CO2 regulator out  
of adjustment.  
B. Adjust CO2 regulator for syrup  
tanks as instructed.  
Syrup Bag-in-Box Sys tem.  
Syrup pumps CO2 regulator  
out of adjustment.  
Adjust syrup pumps CO2  
regulator as instructed.  
C. Dispensing valve syrup flow  
control syrup or syrup line  
restricted.  
C. Sanitize syrup system as  
instructed.  
D. Improper syrup Baume.  
D. Replace syrup supply as  
instructed.  
E. Inoperative dispensing valve  
syrup flow control.  
E. Repair dispensing valve syrup  
flow control.  
F. Tapered gasket inside tube  
swivel nut connection distorted  
from being overtightened  
restricting syrup flow.  
F. Replace tapered gasket. Make  
sure it is properly seated.  
312027000  
42  
Trouble  
Probable Cause  
Remedy  
ADJUSTMENT OF  
A. Dirty or inoperative dispensing A. Disassemble and clean  
DISPENSING VALVE SYRUP  
FLOW CONTROL DOES NOT  
DECREASE TO DESIRED  
WATER-TO-SYRUP RATIO.  
valve syrup flow control.  
dispensing valve syrup flow  
control.  
DISPENSED PRODUCT  
CARBONATION TOO LOW.  
A. Carbonator CO2 regulator out  
of adjustment for existing  
water conditions or  
A. Adjust carbonator CO2 regulator  
as instructed.  
temperature.  
B. Air in carbonated water tank.  
B. Vent air from carbonated water  
tank by dispensing from No. 1  
dispensing valve to make  
carbonator pump motor cycle on.  
C. Water, oil, or dirt in CO2  
supply.  
C. Remove contaminated CO2.  
Clean CO2 system (lines,  
regulators, etc.) using mild  
detergent. Install clean CO2  
supply.  
DISPENSED PRODUCT  
COMES OUT OF  
A. Oil film or soap scum in cups  
or glasses.  
A. Use clean cups or glasses.  
DISPENSING VALVE CLEAR  
BUT FOAMS IN CUP OR  
GLASS.  
B. Ice used for finished drink is  
subcooled.  
B. Do not use ice directly from  
freezer. Allow ice to become wet”  
before using. (Refer to following  
NOTE.)  
NOTE: Crus hed ice als o caus es dis pens ing problems . When  
dis pens ed drink hits s harp edges of ice, carbonation is releas ed from  
drink.  
DISPENSED PRODUCT  
PRODUCES FOAM AS IT  
LEAVES DISPENSING VALVE.  
A. Recovery rate of refrigeration  
unit exceeded, ice bank  
depleted.  
A. Allow ice bank to recover.  
CAUTION: The drop-in refrigeration as s embly condens er coil mus t be  
cleaned every 30-days . Exces s ive accumulation of dus t, lint, and  
greas e on the coil will res trict cooling air flow through the coil and  
caus e the refrigeration s ys tem to overheat.  
B. Condenser coil plugged.  
B. Clean condenser coil as  
instructed.  
C. Carbonator CO2 regulator  
pressure adjusted too high for  
existing water conditions or  
temperature.  
C. Adjust carbonator CO2 regulator  
as instructed.  
D. Dispensing valve restricted or  
dirty.  
D. Sanitize syrup system as  
instructed.  
E. Tapered gasket inside  
carbonated water line swivel  
nut connector distorted  
restricting carbonated water  
flow.  
E. Replace tapered gasket. Make  
sure gasket is properly seated.  
312027000  
43  
Trouble  
Probable Cause  
Remedy  
DISPENSED PRODUCT  
PRODUCES FOAM AS IT  
LEAVES DISPENSING  
VALVE.(CONTD)  
F. Dirty water supply.  
F. Check water filter. Replace  
cartridge (see NOTE).  
NOTE: If water s upply is dirty, be s ure to flus h lines and carbonator  
completely. It may be neces s ary to remove lines to carbonator tank,  
invert tank, and flus h the tank and all inlet lines to remove any  
foreign particles or dirt.  
NO PRODUCT DISPENSED  
FROM ALL DISPENSING  
VALVES.  
A. Dispensing valves keyed  
lock-out switch in OFF”  
position.  
A. Place keyed lock-out switch in  
ON” position.  
B. Power switch (if applicable) in  
OFF” position.  
B. Place power switch in ON”  
position.  
C. No electrical power to Unit.  
C. Plug in Unit power cord or check  
for blown power fuse or tripped  
circuit breaker.  
D. Inoperative power switch (if  
applicable).  
D. Replace power switch.  
E. Dispensing valves power cord  
disconnected.  
E. Connect dispensing valves power  
cord.  
F. Disconnected or broken wiring F. Connect or replace wiring.  
to dispensing valve.  
G. Inoperative transformer or  
valve solenoids.  
G. Replace inoperative part.  
ONLY CARBONATED WATER A. Out of syrup.  
DISPENSED.  
A. Replenish syrup supply as  
instructed.  
B. Inoperable dispensing valve..  
B. Repair dispensing valve.  
C. Dispensing valve syrup flow  
control not properly adjusted.  
C. Adjust dispensing valve syrup  
flow control as instructed.  
D. Dispensing valve syrup flow  
control or syrup lines  
restricted.  
D. Sanitize syrup system as  
instructed.  
ONLY SYRUP DISPENSED.  
A. Water inlet supply line shutoff  
valve closed.  
A. Open water inlet supply line  
shutoff valve.  
B. Carbonator power cord (under B. Remove hood and plug in  
hood) unplugged.  
carbonator power cord.  
C. Carbonator CO2 regulator not  
properly adjusted.  
C. Adjust carbonator CO2 regulator  
as instructed.  
D. Inoperative carbonated water  
tank liquid level control  
assembly.  
D. Replace carbonated water tank  
liquid level control assembly.  
E. Inoperative water pump, water E. Replace inoperative component.  
pump motor, or water pump  
power switch.  
312027000  
44  
TROUBLESHOOTING REFRIGERATION SYSTEM  
Trouble  
Probable Cause  
Remedy  
COMPRESSOR DOES NOT  
OPERATE.  
A. Ice bank sufficient.  
A. Refrigeration not called for.  
B. Unit power cord unplugged,  
power switch (if applicable) in  
OFF” position, or drop-in  
refrigeration assembly power  
cord unplugged.  
B. Plug in power cord(s) or place  
Unit power switch in ON”  
position.  
C. No power source (blown fuse  
or tripped circuit breaker).  
C. Replace fuse or reset circuit  
breaker. (NOTE: Fuse or circuit  
breaker are not part of unit).  
D. Inoperative Unit power switch  
(if applicable) or power cord  
unplugged.  
D. Replace power switch or plug Unit  
power cord into electrical outlet.  
E. Low voltage.  
E. Voltage must be at least 103 volts  
(115 VAC unit) or 208 (230 VAC  
unit) at compressor terminal when  
compressor is trying to start.  
F. Loose, disconnected, or  
broken wiring.  
F. Tighten connections or replace  
broken wiring.  
G. Overload protector cut out;  
overheated compressor.  
Condenser fan motor not  
operating as required.  
G. Compressor will cool enough to  
restart. Do not overdraw cooling  
capacity of Unit. Refer to  
CONDENSER FAN MOTOR  
NOT OPERATING” in this  
section.  
H. Inoperative overload protector H. Replace inoperative part.  
or start relay.  
I.  
Inoperative ice bank control  
probe.  
I.  
Replace ice bank control.  
J. Inoperative compressor.  
J. Call service person.  
COMPRESSOR WILL NOT  
STOP AFTER SUFFICIENT  
ICE BANK IS PRODUCED.  
(NOTE: ICE BANK SHOULD  
JUST COVER CONTROL  
BULB).  
A. Ice bank control cap tube  
kinked or broken.  
A. Replace ice bank control.  
B. Ice bank control stuck in  
closed position.  
B. Replace ice bank control.  
312027000  
45  
Trouble  
Probable Cause  
Remedy  
COMPRESSOR OPERATES  
CONTINUOUSLY BUT DOES  
NOT FORM SUFFICIENT ICE  
BANK.  
A. Cooling capacity is exceeded  
by over-drawing.  
A. Reduce amount of drinks drawn  
per given time.  
B. Unit located in excessively hot B. Relocate unit or check and if  
area or air circulation through  
condenser coil is restricted.  
necessary, clean condenser coil  
as instructed.  
NOTE: Ice bank freezes from bottom of evaporator upward. A  
refrigerant leak or ins ufficient charge might s how an ice bank at  
bottom and not at top of evaporator.  
AGITATOR MOTOR NOT  
OPERATING.  
A. Power switch (if applicable) in  
OFF” position.  
A. Place power switch in  
ON” position.  
B. Unit power cord or  
refrigeration assembly power  
cord unplugged.  
B. Connect power cord(s).  
C. No power source (blown fuse  
or tripped circuit breaker).  
C. Replace fuse or reset circuit  
breaker. (NOTE: Fuse or circuit  
breaker are not part of Unit).  
D. Agitator motor propeller  
obstructed.  
D. Remove obstruction.  
E. Low voltage.  
E. Voltage must be at least 103 volts  
(115 VAC unit) or 208 (230 VAC  
unit) at compressor terminals  
when compressor is trying to  
start.  
F. Loose, disconnected, or  
broken wiring.  
F. Tighten connections or replace  
broken wiring.  
G. Inoperative agitator motor.  
G. Replace agitator motor.  
312027000  
46  
WARRANTY  
IMI Cornelius Inc. warrants that all equipment and parts are free from defects in material and workman-  
ship under normal use and service. For a copy of the warranty applicable to your Cornelius, Remcor or  
Wilshire product, in your country, please write, fax or telephone the IMI Cornelius office nearest you.  
Please provide the equipment model number, serial number and the date of purchase.  
IMI Cornelius Offices  
AUSTRALIA D P.O. 210, D RIVERWOOD, D NSW 2210, AUSTRALIA D (61) 2 533 3122 D FAX (61) 2 534 2166  
AUSTRIA D AM LANGEN FELDE 32 D A-1222 D VIENNA, AUSTRIA D (43) 1 233 520 D FAX (43) 1-2335-2930  
BELGIUM D BOSKAPELLEI 122 D B-2930 BRAASCHAAT, BELGIUM D (32) 3 664 0552  
D
FAX (32) 3 665 2307  
BRAZIL D RUA ITAOCARA 97 D TOMAS COELHO D RIO DE JANEIRO, BRAZIL D (55) 21 591 7150 D FAX (55) 21 593 1829  
ENGLAND D TYTHING ROAD ALCESTER D WARWICKSHIRE, B49 6 EU, ENGLAND D (44) 789 763 101 D FAX (44) 789 763 644  
FRANCE D 71 ROUTE DE ST. DENIS D F-95170 DEUIL LA BARRE D PARIS, FRANCE D (33) 1 34 28 6200 D FAX (33) 1 34 28 6201  
GERMANY D CARL LEVERKUS STRASSE 15 D D-4018 LANGENFELD, GERMANY D (49) 2173 7930 D FAX (49) 2173 77 438  
GREECE D 488 MESSOGION AVENUE D AGIA PARASKEVI D 153 42 D ATHENS, GREECE D (30) 1 600 1073 D FAX (30) 1 601 2491  
HONG KONG D 1104 TAIKOTSUI CENTRE D 11-15 KOK CHEUNG ST D TAIKOKTSUE, HONG KONG D (852) 789 9882 D FAX (852) 391 6222  
ITALY D VIA PELLIZZARI 11 D 1-20059 D VIMARCATE, ITALY D (39) 39 608 0817 D FAX (39) 39 608 0814  
NEW ZEALAND D 20 LANSFORD CRES. D P.O. BOX 19-044 AVONDALE D AUCKLAND 7, NEW ZEALAND D (64) 9 8200 357 D FAX (64) 9 8200 361  
SINGAPORE D 16 TUAS STREET D SINGAPORE 2263 D (65) 862 5542 D FAX (65) 862 5604  
SPAIN D POLIGONO INDUSTRAIL D RIERA DEL FONOLLAR D E-08830 SANT BOI DE LLOBREGAT D BARCELONA, SPAIN D (34) 3 640 2839 D FAX (34) 3 654 3379  
USA D ONE CORNELIUS PLACE D ANOKA, MINNESOTA D (612) 421-6120 D FAX (612) 422-3255  
LD004  
4/21/98  
312027000  
47  
IMI CORNELIUS INC.  
CORPORATE HEADQUARTERS:  
One Cornelius Place  
Anoka, Minnesota 55303-6234  
(612) 421-6120  
(800) 238-3600  

Continental Electric CE11153 User Manual
Cornelius Remcor 2849959020 User Manual
Datalogic Scanning POWERSCAN D8330 User Manual
Epson Stylus CX5000 User Manual
Friedrich 115 Volts US12 User Manual
Friedrich HA09K25 User Manual
GE ZONELINE 2800 User Manual
Goodman Mfg Co LP Air Conditioner goodman High Efficiency 2 to 5 Ton Split System Air Conditioner User Manual
Haier HWF08XC5 User Manual
HoMedics Deluxe Shiatsu Massaging Cushion MCS 600H User Manual