Hunter Fan Outdoor Ceiling Fan 24750 User Manual

Connecting Fan to Electrical Source  
Testing the Control  
Use Figures 2 and 3, for reference in making the following electrical connections.  
Hunter Fan  
Company  
Warning!  
- Do not use the light fixture pull chain to operate the light while power is  
applied to the receiver as damage could occur to the receiver. It is recommended to shorten the  
pull chain(s) to prevent accidental use.  
Connect the supply mains to the terminal block mounted on the hanger bracket.  
Connect the safety earth (green/yellow) wire to the terminal marked  
Connect the blue neutral wire to the terminal marked “N.”  
.
• Do not use the fan pull chain switch to operate the fan speeds while power is applied to the  
receiver as damage could occur to the receiver.  
Remote Ceiling Fan & Light Control  
Connect the brown line wire to the terminal marked “L.”  
When the installation is complete and while there is no power (your wall switch is in the OFF position)  
to the receiver, pull the light kit’s pull chain once and pull the fan speed pull chain once.  
Model: 24750  
Note: An additional “L” terminal is provided for separate control of the light fixture. This terminal is not  
Transmitter Part Number: 87495-01  
Transmitter Battery: 12V, Type A23, MN-21 or equivalent  
Receiver Part Number: 87262-01  
Ratings: 240 VAC, 50Hz, 1.0 Amp Fan  
Receiver Weight: 160g  
Turn on the wall switch. The light kit should turn ON. If the light remains OFF, turn off the power at the  
wall switch. Pull the light kit’s pull chain to turn the light ON.  
required for controlling the light fixture with the remote control.  
Feed the electrical connector from the fan through the hole in the hanger bracket so it is on the outside  
of the hanger bracket.  
Turn the wall switch back ON.  
Press “3” on the remote control (refer to Figure 5). The fan should start and reach it’s maximum speed.  
If the fan does not start or is turning too slow, turn off the power at the wall switch. Pull the fan’s pull  
chain to change speed. Reapply power and try HIGH.  
The remote receiver is connected between the electrical connector coming from the fan and the electrical  
connector coming from the hanger bracket terminal block. See Figure 2.  
Max 300 Watts Incandescent or Halogen Light  
Read and Save these Instructions  
Operation  
Turn ON the wall switch, the light will turn ON at maximum brightness and the fan will be off.  
WARNING! Risk of Electrical Shock  
• To avoid possible electrical shock, before wiring fan, disconnect power by turning off the power  
mains both to the outlet box and to its associated wall switch location.  
Compliance  
• This equipment has been tested and complies with: EN 300220:2002 and EN 55022:1998 Class  
B.  
Fan Operation  
• ON, OFF, and Speed Setting: To turn the ceiling fan  
Fan High = 3  
Fan Medium = 2  
Fan Low = 1  
on, press either “1”, “2”, or “3” on the remote control. To  
change the speed of the ceiling fan, press “1” for slow,  
“2” for medium, and “3” for fast. To turn the ceiling fan  
off, press “0”.  
• All wiring must be in accordance with national and local electrical codes. If you are unfamiliar  
with wiring, you should use a qualified serviceman.  
Fan OFF = 0  
To reverse the fan direction, turn the fan off and wait for  
the blades to stop moving. Switch the reversing switch  
on the fan to the opposite direction. Restart fan.  
• To avoid overheating and possible damage to other equipment, do not install to control  
a receptacle, fluorescent light fixture, motor-operated appliance, or transformer-supplied  
appliance.  
• In Australia, national laws require a quailfied electrician to install this accessory into a ceiling  
fan.  
Figure 5  
Light Operation  
• Use only to control one paddle-blade ceiling fan and incandescent or halogen light fixture.  
• ON and OFF: Press and quickly release the light button on the hand-held remote to turn the light  
NOTE: Any changes or modifications to the transmitter or receiver not expressly approved by Hunter  
OFF and ON. See Figure 5 for remote button locations.  
Fan Company may void one’s authority to operate this remote control.  
Figure 2 - Wiring Diagram  
For use only with electrically reversible ceiling fans rated at 1.0 A or less, and fan incandescent light  
kits rated at 300 W or less.  
Dimmer  
Press and hold the light button for more than one second to dim or brighten the light. If brightness is  
initially at 100%, then the brightness will decrease as long as the light button is pressed. When the  
minimum brightness of 25% is reached, the setting will pause and then begin to increase as long as  
the light button is pressed.  
If this equipment does cause harmful interference to radio or television reception, which can be determined  
by turning the equipment off and on, the user is encouraged to try to correct the interference by one or  
more of the following measures:  
• Reorient or relocate the receiving antenna.  
• Increase the separation between the equipment and receiver.  
Troubleshooting  
• Connect the equipment into an outlet on a circuit different from that to which the receiver is  
connected.  
Symptom  
Possible Causes  
Solution  
• Consult the dealer or an experienced radio/TV technician for help.  
Figure 3 - Terminal Block Connections  
1. No functions operate.  
Main Power not restored.  
Replace fuse. Turn ON supply mains.  
Turn ON wall switch.  
Installing the Receiver  
Disconnect the power mains to the ceiling fan and light kit at the main electric panel. Remove fuse or  
move circuit breaker to the OFF position. Turn off wall switch.  
Fan pull chain not set to HIGH.  
Turn OFF power at wall switch or  
main supply mains. Set fan to HIGH  
speed.  
Slide the remote receiver through the two rectangular openings in the hanger bracket and center it in  
the hanger bracket, as shown in Figure 4.  
The male connector on the remote receiver attaches to the female connector on the fan. The female  
connector on the remote receiver attaches to the male connector on the hanger bracket. They are  
keyed so they will only connect one way. See Figure 2.  
Set light kit to ON.  
IMPORTANT! Before installing this control, change the factory default DIP switch settings to your own  
unique code. The DIP switches are under the battery compartment on the remote and are on the flat  
side of the receiver. Refer to Figure 1. Remove the battery from the remote and turn off power to the  
fan when making any DIP switch setting changes.  
Light pull chain not set to ON.  
Receiver wiring incorrect.  
Verify wiring connections.  
Set transmitter and receiver to same  
DIP switch setting.  
Transmitter and receiver DIP  
switches do not match.  
Hanger  
Bracket  
Replace with new, alkaline battery.  
Battery too weak.  
2. Operates only at  
close range.  
Receiver Back  
Extend antenna into wire into ceiling  
box, or move it for better reception.  
Signal blocked from reaching  
receiver  
3. Inconsistent operation. Battery too weak.  
Replace with new, alkaline battery.  
Signal partially blocked from  
Extend antenna into ceiling box, or  
move it for better reception.  
Dip Switch  
reaching receiver.  
RF interference.  
ON DIP  
Remote  
Receiver  
Turn OFF wall switch for 5 seconds,  
then turn back ON.  
1
2
3
4
Dip Switch  
Change dip switch settings to a  
different code in both Transmitter  
and Receiver.  
Continuing RF interference.  
Transmitter Back  
Figure 1 - Setting DIP Switches  
Figure 4 - Remote Receiver in Hanger Bracket  
Be sure the DIP switch settings of the transmitter and receiver match, or the ceiling fan will not function.  
Make sure the DIP switch combination of your ceiling fan transmitter and receiver is different from the  
DIP switch combinations of any other receivers and transmitters in your home (garage door openers,  
other ceiling fans, entertainment equipment, etc.).  
Do not force the connectors. To aid in proper connection, align the color code stickers on each connector  
so they are in line with each other then press them together until they lock.  
CAuTIoN: Be sure no bare wire or wire strands are visible after making connections.  
Make sure none of the wires are caught in any of the hanging assembly components. The white  
antenna wire should be extended to its full length and positioned between the hanger bracket  
and the canopy parts upon final assembly.  
Install one type A23, MN-21 or equivalent, 12 volt alkaline battery inside the hand-held transmitter  
after setting the DIP switch settings on the remote to match the ON / OFF DIP switch settings on the  
receiver. Refer to Figure 1.  
Install the ceiling fan according to its instructions, up to the point of making the electrical connections.  
Once the receiver is installed, continue with the appropriate instructions from the fan installation manual  
to finish installing the fan.  
Hunter Fan Company  
2500 Frisco Avenue  
Memphis TN 38114 USA  
© 2006 Hunter Fan Company  
43520-01 16/10/06  
Download from Www.Somanuals.com. All Manuals Search And Download.  

GPX Stereo System HM3817 User Manual
Gravely Lawn Mower Accessory 890015 User Manual
Grizzly Lathe G9730 User Manual
Hearth and Home Technologies Indoor Fireplace TRUE 36 User Manual
Heatiator Indoor Fireplace NNXT3933IL User Manual
Hotpoint Oven SX 896L PX User Manual
Hotpoint Washer BHWMD 732 User Manual
Icom Marine Radio IC F9511HT User Manual
iHome CD Player iA100 User Manual
Image Home Gym IMBE19500 User Manual