Honeywell Laptop MX7 User Manual

MX7 Tecton™ Mobile Computer  
®
®
with Microsoft Windows Mobile 6.5  
User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
i
Download from Www.Somanuals.com. All Manuals Search And Download.  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MX7 Tecton OS Upgrade ...................................................................................................................5-7  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MX7 Tecton Options ..................................................................................................................5-40  
v
Download from Www.Somanuals.com. All Manuals Search And Download.  
MX7 Tecton with a Disabled Touch Screen...............................................................................5-72  
Configuring the MX7 Tecton with HSM Connect (or LXEConnect) ..................................................5-73  
vi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MX7 Tecton with Label...............................................................................................................7-11  
MX7 Tecton without Label..........................................................................................................7-11  
vii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
viii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ix  
Download from Www.Somanuals.com. All Manuals Search And Download.  
x
Download from Www.Somanuals.com. All Manuals Search And Download.  
Tethered Scanners and the MX7 Tecton Cradles ............................................................................14-2  
xi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
xii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
xiii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
xiv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
MX7 Tecton Agency Compliance  
MX7 Tecton mobile computers meet or exceed the requirements of all applicable standards organizations for safe operation.  
However, as with any electrical equipment, the best way to ensure safe operation is to operate them according to the agency  
guidelines that follow. Read these guidelines carefully before using your MX7 Tecton.  
This documentation is relevant for the following models: Tecton, TectonCS.  
Caution: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. The battery should be disposed of  
by a qualified recycler or hazardous materials handler. Do not incinerate the battery or dispose of the battery with  
general waste materials.  
!
Laser Warnings  
Do not look into the laser’s lens.  
Do not stare directly into the laser beam.  
Do not remove the laser caution labels from the Tecton.  
Do not connect the laser bar code aperture to any other device. The laser bar code aperture is certified for use with the MX7  
Tecton only.  
Caution: Laser radiation when open. Read the caution labels. Use of controls, adjustments or performance of procedures other  
than those specified herein may result in hazardous radiation exposure.  
!
Laser Label Location  
If the following label is attached to your product, it indicates  
the product contains an engine with a laser aimer:  
AVOID EXPOSURE - LASER RADIATION IS  
EMITTED FROM THIS APERTURE.  
EN60825-1:2007 IEC60825-1:2007  
COMPLIES WITH 21 CFR 1040.10 AND 1040.11  
LASER LIGHT - DO NOT STARE INTO BEAM  
CLASS 2 LASER PRODUCT  
1.0mW - 630 - 680nm  
Laser Safety Statement  
This device has been tested in accordance with and complies with IEC60825-1 ed2 (2007). Complies with 21 CFR 1040.10 and  
1040.11, except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007.  
LASER LIGHT, DO NOT STARE INTO BEAM, CLASS 2 LASER PRODUCT, 1.0 mW MAX OUTPUT: 630-680nM.  
Model Number and Serial Number Labels  
The model (item) number and serial number for the terminal are located on labels affixed to the back of the terminal.  
FCC Part 15 Statement  
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:  
1. This device may not cause harmful interference.  
2. This device must accept any interference received, including interference that may cause undesired operation.  
1 - 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC  
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This  
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the  
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not  
occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be  
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the  
following measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and receiver.  
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  
Consult the dealer or an experienced radio or television technician for help.  
If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The  
user may find the following booklet helpful: “Something About Interference. This is available at FCC local regional offices. Hon-  
eywell is not responsible for any radio or television interference caused by unauthorized modifications of this equipment or the  
substitution or attachment of connecting cables and equipment other than those specified by Honeywell. The correction is the  
responsibility of the user.  
Caution: Any changes or modifications made to this equipment not expressly approved by Honeywell may void the FCC autho-  
rization to operate this equipment.  
FCC 5GHz Statement  
LAN devices are restricted to indoor use only in the band 5150-5250 MHz. For the band 5600-5650 MHz, no operation is permit-  
ted.  
When using IEEE 802.11a wireless LAN, this product is restricted to indoor use, due to its operation in the 5.15- to 5.25-GHz  
Frequency range. The FCC requires this product to be used indoors for the frequency range of 5.15 GHz to 5.25 GHz to reduce  
the potential for harmful interference to co-channel mobile satellite systems. High-power radar is allocated as the primary user  
of the 5.25- to 5.35-GHz and 5.65- to 5.85-GHz bands. These radar stations can cause interference with and/or damage to this  
device.  
Canadian Compliance  
This ISM device complies with Canadian RSS-210.  
Operation is subject to the following conditions:  
1. This device may not cause harmful interference.  
2. This device must accept any interference received, including interference that may cause undesired operation.  
This Class B digital apparatus complies with Canadian ICES-003.  
1 - 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CE Mark  
The CE marking indicates compliance with the following directives:  
1995/5/EC R&TTE  
2011/65/EU RoHS (Recast)  
In addition, complies to 2006/95/EC Low Voltage Directive, when shipped with recommended power supply. European contact::  
Hand Held Products Europe BV  
Nijverheidsweg 9-13  
5627 BT Eindhoven  
The Netherlands  
Honeywell shall not be liable for use of our product with equipment (i.e., power supplies, personal computers, etc.) that is not CE  
marked and does not comply with the Low Voltage Directive.  
RF Notices  
This device (FCC ID: KDZLXE-MX7T and IC ID: 1995B-LXEMX7T) contains transmitter Module FCC ID: TWG-SD-  
CMSD30AG and IC ID: 6616A-SDCMSD30AG.  
This device does not transmit simultaneously on adjacent or non-adjacent channels.  
RF Safety Notice  
Caution:  
This device was tested for typical body-worn operation. Use only Honeywell tested and approved accessories to ensure FCC  
Compliance. The use of third-party accessories may not comply with FCC RF exposure compliance requirements, and should  
be avoided. To comply with FCC RF exposure requirements, this device must be operated in the hand with a minimum separa-  
tion distance of 2.5 cm (0.9842 inch) or more from a person's body.  
Bluetooth  
Class II  
Honeywell Scanning & Mobility Product Environmental Information  
Refer to www.honeywellaidc.com/environmental for the RoHS / REACH / WEEE information.  
Dealer License - Republic of Singapore  
Vehicle Power Supply Connection Safety Statement  
Vehicle Power Supply Connection: If the supply connection is made directly to the battery, a 10A slow-blow fuse should be  
installed in the positive lead within 5 inches (12.7 cm) of the battery positive (+) terminal.  
1 - 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
             
1 - 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2
Getting Started  
Overview  
The MX7 Tecton™ is a rugged, portable, hand-held mobile computer capable of wireless data communications. The MX7 Tec-  
ton can transmit information using an 802.11 network card and it can store information for later transmission through an RS232  
or USB port. The MX7CS (Cold Storage) device functions normally in various temperature ranges.  
The MX7 Tecton is vertically oriented and features backlighting for the display. Keypads are available in 55-key alphanumeric  
and 32-key numeric-alpha versions.  
This device can be scaled from a limited function batch computer to an integrated wireless scanning computer. A trigger handle  
is available as an accessory.  
The stylus attached to the hand strap is used to assist in entering data and configuring the device. Protective film for the touch  
screen is available as an accessory.  
The MX7 Tecton is powered by a 2200 mAh Lithium-Ion main battery pack and an internal Super-capacitor (Super-cap) battery.  
Note: Contact Technical Assistance (page 16-1) for upgrade availability if your application or control panels are not the same  
as the application or control panels presented in this guide.  
About this Guide  
This MX7 Tecton User’s Guide provides instruction for the system administrator to follow when configuring a MX7 Tecton. Also  
included are setup and use instructions for the MX7 Tecton Battery Charger, Desktop Cradle, Passive Vehicle Mounted Cradle,  
and Powered Vehicle Mounted Cradle.  
Note: The MX7 Tecton may have a Microsoft Windows CE 6 or Microsoft Windows Mobile 6.5 operating system. This guide is  
for the MX7 Tecton with a Windows Mobile 6.5 operating system  
Out of the Box  
After you open the shipping carton verify it contains the following items:  
MX7 Tecton  
Rechargeable battery  
Hand Strap (attached to the MX7 Tecton)  
Quick Start Guide  
Getting Started Disc  
If you ordered accessories for the MX7 Tecton, verify they are also included with the order. Keep the original packaging material  
in the event the MX7 Tecton should need to be returned for service. For details, see Product Service and Repair (page 16-1)  
2 - 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Initial Setup for MX7 Tecton  
Following are steps you might take when setting up a new MX7 Tecton. Follow the links for further instruction for each step. Con-  
tact Technical Assistance (page 16-1) if you need additional help.  
Note: Installing or removing accessories should be performed on a clean, well-lit surface. When necessary, protect the work  
surface, the MX7 Tecton, and components from electrostatic discharge.  
Hardware Setup  
1. Connect accessories e.g., hand strap (if necessary), trigger handle, etc.  
2. Provide a power source:  
Insert a fully charged main battery.  
Connect a power cable (USB/Power or Serial/Power).  
Place the MX7 Tecton in a powered desktop or vehicle mounted cradle.  
3. Press the Power key.  
Software Setup  
Hardware setup should be completed before starting software setup.  
1. Calibrate Touch display.  
2. Set Date and Time Zone.  
3. Set Power Timers.  
4. Set Speaker Volume.  
5. Pair Bluetooth devices.  
6. Set Wireless client parameters.  
7. Set terminal emulation parameters.  
8. Set AppLock parameters.  
9. Set DCWedge parameters.  
2 - 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Components  
Front View  
1. Scanner/Imager Aperture  
2. Speaker  
3. System Status LED  
4. Scan Button  
5. Orange Key (Sticky Key)  
6. Blue Key (Sticky Key)  
7. Scan Status LED  
8. Cable Port  
9. On / Off Button  
10. Alpha Lock LED (32 Key  
keypad only)  
55-key Keypad  
32-key Keypad  
Diamond Keys  
2 - 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Back View  
1. Scanner/Imager Aperture  
2. Stylus and Stylus Pocket  
3. Trigger Handle Attach Points  
4. Main Battery  
5. Battery Fastener  
6. Cable Port  
I/O Port and Cables  
Input / Output Port (I/O)  
Cable: Multipurpose RS232 and Power (MX7055CABLE)  
Cable: Multipurpose USB and Power (MX7052CABLE)  
2 - 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Adapter/Cable: Audio (MX7060CABLE)  
Adapter: RS232 PC port to D9 male (MX7058CABLE)  
Scanner / Imager Aperture  
1. Scanner Aperture  
2. MX7 Tecton Front  
Caution: Never stare directly into the beam aperture.  
If Continuous Scan Mode has been enabled (disabled by default, setting can be changed by user), the laser is always on  
and decoding and the laser beam is emitted continuously.  
2 - 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Handle  
1. Imager / Scanner Aper-  
ture  
2. Trigger  
3. Handle  
4. Tether Attach Point  
Handstrap  
1. Handstrap  
2. Handstrap Retainer Bracket and mounting screws  
3. Handstrap Clip  
2 - 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Keypads  
55 Key Primary Delete ANSI Keypad  
1. System Status LED  
2. Volume Control Icon  
3. On Off Button  
10  
1
2
9
8
4. Scan Status LED  
5. Orange Key (Sticky Key)  
6. Blue Key (Sticky Key)  
7. Enter Key  
8. Scan Button  
7
9. Diamond Key  
10. Display Brightness Icon  
3
4
6
5
Spc and Del key location  
55 Key Primary Backspace ANSI Keypad  
1. System Status LED  
2. Volume Control Icon  
3. On Off Button  
10  
1
2
9
8
4. Scan Status LED  
5. Orange Key (Sticky Key)  
6. Blue Key (Sticky Key)  
7. Enter Key  
Del  
BkSp  
8. Scan Button  
7
9. Diamond Key  
10. Display Brightness Icon  
Del  
BkSp  
3
4
6
5
Spc and Bksp key location  
2 - 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
32 Key Numeric-Alpha Keypad  
1. System Status LED  
2. Alpha Status LED  
3. Diamond Keys  
4. Scan Button  
10  
1
2
3
5. Enter Key  
6. Alph Key  
7. Orange Key (Sticky Key)  
8. Blue Key (Sticky Key)  
9. On Off Button  
9
10. Scan Status LED  
8
7
4
5
6
Locking and Unlocking the MX7 Tecton  
Locking the MX7 Tecton  
The MX7 Tecton can be locked manually by tapping Start > Lock. By default, this option is included on the Start screen at the  
bottom of the screen. Care should be taken to not accidentally tap this area of the Start screen.  
Note: Review the Unlock process before locking the MX7 Tecton.  
Lock can be removed from the Today screen by selecting Start > Settings > Today > Items (page 5-22) tab. Deselect Device  
Lock.  
The MX7 Tecton can also be configured to Lock automatically after a defined period of inactivity. This setting is accessed via  
Start > Settings > Lock > Password tab. By default, this option is Disabled.  
The password and hint are configured by selecting Start > Settings > Lock > Password (page 5-16) and Hint (page 5-17) tabs.  
Unlocking the MX7 Tecton  
When the MX7 Tecton is locked, the Start screen displays Unlock at the lower part of the screen.  
If there is no password or PIN set, tap Unlock on the next screen to unlock the MX7 Tecton. The MX7 Tecton is returned  
to normal operation.  
If there is a password or PIN set, enter the password/PIN and tap Unlock. If several unsuccessful attempts are made, the  
MX7 Tecton may be configured to display a password hint.  
2 - 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Rebooting the MX7 Tecton  
When the Desktop/Start screen is displayed or an application begins, the power up sequence is complete. If you have previ-  
ously saved your settings, they will be restored on reboot. Application panel changes are saved when OK is tapped on an appli-  
cation properties panel.  
During the processes that follow there may be small delays while MX7 Tecton wireless clients connect to the network and Blue-  
tooth relationships establish or re-establish.  
Suspend / Resume  
Quickly tapping the Power key places the MX7 Tecton in Suspend mode. Quickly tapping the Power key again, pressing any  
key, pressing the trigger (on the trigger handle), or tapping the touch screen, returns the MX7 Tecton from Suspend and to  
the exact state before the Power key press. The System LED blinks green when the video display is Off (and the device is  
not in Suspend Mode or critical suspend).  
Warmboot  
A warmboot reboots the MX7 Tecton without erasing any registry data. Configuration settings and data in RAM are pre-  
served during a warmboot. Network sessions are lost and any data in running applications that has not been previously  
saved may be lost. CAB files already installed remain installed.  
Using the Registry control panel, tap the Warmboot button. The MX7 Tecton immediately warmboots.  
Restart  
The OS and CAB files are reloaded. Restart erases the contents of RAM but preserves all registry configuration settings.  
Any files that are stored only in RAM drives will be lost. Restart erases any user-stored applications or data, but preserves  
anything stored on the System drive in flash (which are files explicitly copied to the System folder, plus the registry files cre-  
ated by the OS). All CABs and applications that are configured are reinstalled by the Launch utility. Touch screen calibration  
data is preserved. Network sessions are lost, and any data in running applications that has not been specifically sent to  
storage may be lost.  
Tap the Restart button on the Registry control panel. The operating system performs the operation and the MX7 Tecton  
restarts.  
An alternate method to Restart is to hold down the Blue key, the Scan key and the Power key until the screen blanks.  
Release the keys and the MX7 restarts (may also be called a cold boot). Be sure the press the Scan key, not the Enter  
key. Pressing the Enter key begins a warmboot function instead of a coldboot function.  
Clean Boot / Reset  
Important -- Because of the extreme nature of resetting the Windows Mobile device to factory default settings, this process  
should be used only as an emergency procedure and suspend/resume or restart should be used whenever necessary.  
To reset all Windows Mobile device configuration to factory defaults:  
1. Hold down the Blue + Scan + Power keys at the same time. After the key sequence is complete, the display turns solid  
white. Be sure to press the Scan key, not the Enter key.  
2. Release the keys and immediately press and hold the Enter + Scan keys. After the keypress, the display turns dark. (If  
these keys are not pressed immediately the MX7 Tecton performs a Cold Boot. Wait until the MX7 Tecton boots and try  
again.)  
3. Release the Reset key sequence. A message is displayed stating the change is in process. If the message does not  
appear, try again.  
When all programs have finished loading, the Windows Mobile Start screen is displayed. If prompted, tap the touch screen  
to set up your Windows Mobile based device.  
2 - 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Inserting and Removing the Battery Pack  
Note: The battery should not be replaced in a dirty, harsh or hazardous environment. When the battery is not connected to the  
MX7 Tecton, any dust or moisture that enters the battery well or connector may transfer to the battery/well terminals,  
potentially causing damage. Only use Honeywell batteries as replacements: MX7A380BATT / MX7392BATT or a Low  
Temperature (CS) Battery : MX7A381BATT / MX7393BATT / MX7396BATTERY.  
The MX7 Tecton will not function unless the battery pack is in place and securely latched. Any work in progress should be saved  
prior to replacing the battery pack.  
Be sure to place the unit in Suspend Mode before removing the battery. Failing to properly place the device in Suspend mode  
will result in a loss of all unsaved data.  
An MX7 Tecton will retain data, while the main battery is removed and replaced with a fully charged main battery, for 5 minutes.  
Note: When internal battery power is Low or Very Low connect the AC/DC adapter to the MX7 Tecton before replacing the main  
battery.  
Inserting the Battery  
To insert the main battery, complete the following steps:  
1. Place the MX7 Tecton in Suspend Mode (if On).  
2. Detach the bottom hook of the handstrap (if installed).  
3. Tilt the end (without the latch) of the fully charged battery pack into the upper end of the battery compartment, and  
firmly press the other end down until it is fully inserted into the battery compartment  
4. Push down on the battery until the retaining clip clicks into place. The MX7 Tecton draws power from the battery  
immediately upon successful connection.  
5. Replace the handstrap clip in its holder (if installed).  
Removing the Battery  
To remove the battery, complete the following steps:  
1. Place the MX7 Tecton in Suspend mode (if On).  
2. Detach the bottom hook of the handstrap (if installed).  
3. Slide the battery retaining clip down to release the main battery.  
4. Pull the battery up and out of the battery compartment.  
5. Place the discharged battery pack in a powered battery charger to re-charge.  
Charging the Main Battery  
Note: The MX7 Tecton Battery Charger is designed for an indoor, protected environment.  
New batteries must be fully charged prior to use.  
The main battery can be recharged in an AC powered Battery Charger after the battery has been removed from the MX7 Tecton  
or its packing material when new.  
The main battery can be recharged while it is in the MX7 Tecton:  
by connecting the MX7 Tecton AC power adapter to the I/O connector at the base of the MX7 Tecton.  
by docking the MX7 Tecton in a powered desk cradle.  
by docking the MX7 Tecton in a powered vehicle cradle.  
or by connecting the car power adapter (CLA) to the I/O connector at the base of the MX7 Tecton.  
Note: An uninterrupted external power source (wall AC adapters) transfers power to the computer’s internal charging circuitry  
which, in turn, recharges the main battery and internal battery. Frequent connection to an external power source, if  
feasible, is recommended to maintain internal battery charge status as the internal battery cannot be recharged by a dead  
or missing main battery.  
2 - 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
LEDs and Indicators  
The Scan Status oval shaped indicator is situated below the keypad and next to the On button.  
LEDs (Light Emitting Diodes) are located on the front of the MX7 Tecton. They are:  
System Status LED indicates power management status. It is located at the top left of the keypad, below the F3 key.  
Alpha Mode Status LED applies to the 32-key keypad only. It is located below the F4 key on the 32-key keypad.  
System Status LED  
Blinking Red  
Steady Red  
Blinking Green  
Yellow / Amber  
No Color  
Battery power fail; critical suspend mode.  
Main battery low.  
Display turned off.  
A few seconds when Power key is pressed.  
No user intervention required.  
Alpha mode Status LED  
Steady Green  
No Color  
Device is in “Alpha” character input mode.  
Device is in “Numeric” key input mode.  
Scan Status Indicator  
Steady Green  
Steady Amber  
Steady Red  
No Color  
Good scan.  
Decoder engine storing changed parameters.  
Scan in progress.  
Scanner / Imager ready for use or no scanner installed.  
Toggle Vibrate Indicator  
The vibration motor is activated when a scan is completed successfully (good scan vibration) or with a failure (scan key  
released before good scan, timeout, or rejected because of Data Options configuration). The vibrations can be detected  
under the handstrap or through the trigger handle.  
Vibrate indicator is toggled on and off in the Data Collection application, using the Notification tab. Toggle the vibrate indica-  
tor on or off by tapping the desired radio button for Good Scan Vibration and Bad Scan Vibration.  
Options are: Off, Short, Medium or Long.  
Vibration can also be adjusted by tapping the speaker icon in the top right corner of the Start screen. A Volume window  
opens. Tap the Vibrate radio button to toggle vibration on and off. Vibration duration can be set using the Data Collection  
control panels.  
2 - 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Tapping the Touch Screen with a Stylus  
Note: Always use the point of the stylus for tapping or making strokes on the touch screen.  
Never use an actual pen, pencil, or sharp/abrasive object to write on the touch screen.  
Hold the stylus as if it were a pen or pencil. Touch an element on the screen with the tip of the stylus then lift the stylus from the  
screen. Using a stylus is similar to moving the mouse pointer then left-clicking icons on a desktop computer screen.  
Firmly press the stylus into the stylus holder when the stylus is not in use. There is a stylus holder in the hand strap and the trig-  
ger handle. A stylus replacement kit is available.  
Using the stylus to tap icons on the touch screen is the basic action that can:  
Open applications.  
Choose menu commands.  
Select options in dialog boxes or drop-down boxes.  
Drag the slider in a scroll bar.  
Select text by dragging the stylus across the text.  
Place the cursor in a text box prior to typing in data.  
Place the cursor in a text box prior to retrieving data using a bar code decoder or an input/output device connected to a serial  
port on a cradle.  
Calibrating the Touch Screen  
If the touch screen is not responding properly to stylus taps, you may need to recalibrate the touch screen.  
Recalibration involves tapping the center of a target. If you miss the center, keep the stylus on the screen, slide it over the tar-  
get's center, and then lift the stylus.  
To recalibrate the screen, select Start > Settings > System > Screen (page 5-46) > General tab. To begin, tap the Align Screen  
button on the display with the stylus.  
Follow the instructions on the screen and press the Enter key to save the new calibration settings or press Esc to cancel or quit.  
Setting the Display Backlight Timer  
The backlight settings use Honeywell-determined default timeouts. Different timeouts can be set for the backlights when using  
main battery or external power. The backlights timer can be disabled for a particular mode by unchecking a check box. When  
the backlight timer is disabled (check box is unchecked), the backlight never turns off (or dims) in that mode.  
Default values are 30 seconds for Battery, 1 minute for External. Brightness level default value is 60% for the keypad and dis-  
play.  
When the backlight timer expires, the display backlight and the display are Off, as is the keypad backlight. The backlights are  
turned on when the touch screen is tapped or a button is pressed. Adjust these settings using the Backlight control panel.  
Applying the Touch Screen Protective Film  
1. Clean the touch screen of fingerprints, lint particles, dust and smudges.  
2. Remove the protective film from its container. Remove any protective backing from the film sheet by lifting the backing from  
a corner of the film. Discard the backing.  
3. Apply the film to the touch screen starting at one side and smoothing it across the display.  
4. If air bubbles appear, raise the film slightly and continue smoothing the film across the display until it covers the glass  
surface of the display.  
5. If dust, lint or smudges are trapped between the protective film and the glass display, remove the protective film, clean the  
display and apply the protective film again.  
2 - 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Setting the Date and Time Zone  
Note: The first time the MX7 Tecton is powered up, or the device powers up from a reset/cold boot, the time may be reset to the  
factory default value.  
Set the current date, time, time zone and assign a daylight savings location using control panels. Or double-tap the Date icon in  
the taskbar to begin.  
There is very little functional change from standard desktop PC Date/Time Properties options. Adjust the settings and tap the  
OK button or the Apply button to save changes to the registry. Any changes take effect immediately.  
Setting Speaker Volume  
The speaker is located on the front of the device, between MX7 and Tecton.  
Speaker volume can be adjusted to a comfortable level for the listener by using key presses or by changing settings in a control  
panel. Speaker sounds can be disabled.  
Using the Keypad  
Note: Speaker sounds must be enabled before the following key sequences can adjust the volume.  
The volume is increased or decreased one step each time the volume key sequence is pressed.  
To adjust speaker volume:  
Tap the Orange key then the Scan key to enter volume change mode.  
Use the Up Arrow and Down Arrow keys. A beep is emitted at each arrow key press. When the volume reaches maximum  
level, two extra beeps are emitted.  
Press any key, except the keys you used to adjust the volume, to exit.  
Volume control using a keypad key press has six volume settings that match those supported by the control panel. Volume  
does not “roll-over” from minimum to maximum or from maximum to minimum. Continuously holding down the up or down  
arrow keys does not cause an automatic repeat of the up (or down) arrow key.  
Using a Control Panel  
Sounds for Events and Programs are enabled by default. Notifications are disabled by default. See Sounds & Notifications  
1. Tap the speaker icon in the top right corner of the Start screen. A Volume window opens.  
2. Move the slider up and down to adjust the speaker volume.  
3. If desired, tap the Off radio button to turn sounds off.  
4. If desired, tap the Vibrate radio button to turn Vibrate on. Vibrate is off by default.  
2 - 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Setting Terminal Emulation Parameters  
Before you make a host connection, you will, at a minimum, need to know:  
the alias name or IP address (Host Address) and  
the port number (Telnet Port) of the host system to properly set up your host session.  
1. Make sure the MX7 Tecton network settings are configured and functional. If you are connecting over wireless LAN  
(802.11x), make sure your MX7 Tecton is communicating with the Access Point.  
2. From Start > Programs, run RFTerm or tap the RFTerm icon on the desktop.  
3. Select Session > Configure from the application menu and select the host type that you require. This will depend on the  
type of host system that you are going to connect to; i.e., 3270 mainframe, AS/400 5250 server or VT host.  
4. Enter the Host Address of the host system that you wish to connect to. This may either be a DNS name or an IP address of  
the host system.  
5. Update the telnet port number, if your host application is configured to listen on a specific port. If not, use the default telnet  
port.  
6. Select OK.  
7. Select Session > Connect from the application menu or tap the Connect button on the Tool Bar.  
8. Upon a successful connection, you should see the host application screen displayed.  
To change options such as Display, Colors, Cursor, Bar Code, etc., refer to these sections in the RFTerm User’s Guide for com-  
plete descriptions of these and other features.  
Using the AppLock Switchpad  
Note: The touch screen must be enabled.  
Switchpad Icon  
Switchpad Menu  
Tap the switchpad icon in the taskbar.  
A checkmark on the switchpad menu indicates applications currently active or available for Launching by the MX7 Tecton user.  
When Keyboard, on the Switchpad Menu, is selected, the default input method (Input Panel, Transcriber, or custom input  
method) is activated.  
Using the Keypad  
One switch key sequence (or hotkey) is defined by the Administrator for the end-user to use when switching between locked  
applications. This is known as the Activation key.  
When the Activation key sequence is pressed on the keypad, the next application in the AppLock configuration is moved to  
the foreground and the previous application moves to the background. The previous application continues to run in the  
background. MX7 Tecton key presses affect the application in focus only.  
Using the Touch Screen  
The Switchpad Menu figure shown above is an example and is shown only to aid in describing how the user can switch  
between applications using a stylus.  
When the user taps the Switchpad icon with the stylus, a menu pops up listing the applications available to the user. The  
user can tap an application name in the popup menu and the selected application is brought to the foreground. The previ-  
ous application continues to run in the background. Stylus taps affect the application in focus only. When you need to use  
the Input Panel, tap the Keyboard option. Input Panel taps affect the application in focus only.  
2 - 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Using the Input Panel / Virtual Keyboard  
The input panel / virtual keyboard is always available when needed e.g., text entry.  
Place the cursor in the text entry field and, using the stylus:  
Tap the Shift key to type one capital letter.  
Tap the CAPS key to type all capital letters.  
Tap the áü key to access symbols.  
Some applications do not automatically display the Input Panel. In this case, do the following to use the Input Panel:  
Keyboard icon in the taskbar  
Transcriber icon in the taskbar  
Block recognizer or Letter recognizer icon in the taskbar  
1. If the keyboard icon is not displayed in the taskbar, tap the icon which is present.  
2. Tap the up arrow beside the icon and select Keyboard.  
3. Tap the Keyboard icon in the taskbar. Tapping the Keyboard icon in the taskbar is a toggle action (On/Off).  
4. Move the cursor into the text entry field when you want to enter data using the Input Panel.  
5. When finished entering data, tap the icon in the Taskbar again.  
2 - 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Connecting to Bluetooth Devices  
Before connecting to Bluetooth Devices:  
The system administrator, using the options on the EZPair (or LXEZ Pairing) control panel has discovered, paired, connected  
and disconnected Bluetooth devices for the MX7 Tecton.  
The system administrator has enabled and disabled EZPair (or LXEZ Pairing) parameters for the MX7 Tecton.  
The system administrator has also assigned a Computer Friendly Name using the EZPair (or LXEZ Pairing) control panel for  
the MX7 Tecton.  
To connect Bluetooth devices, the MX7 Tecton should be as close as possible and in direct line of sight (distances up to 32.8  
feet or 10 meters) with the targeted Bluetooth device during the discovery and pairing process.  
If the Bluetooth devices are in Suspend, tap the power key to wake the MX7 Tecton.  
Using the correct procedure, wake the targeted Bluetooth device if necessary.  
There may be audible or visual signals as both devices discover and pair with each other.  
Taskbar Bluetooth Indicator  
MX7 Tecton is connected to one or more of the targeted Bluetooth device(s).  
MX7 Tecton is not connected to any Bluetooth device.  
MX7 Tecton is ready to connect with any Bluetooth device.  
MX7 Tecton is out of range of all paired Bluetooth device(s). Connection is inactive.  
There may be audible or visual signals from paired devices as they move back into range and re-connect with the Bluetooth  
client in the MX7 Tecton.  
2 - 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Attaching the Handstrap  
Note: Either the trigger handle is attached to the MX7 Tecton or the handstrap is attached, not both. In the absence of a trigger  
handle, the handstrap should be used at all times. The handstrap is pre-installed on a MX7 Tecton.  
1. Handstrap Retainer Bracket  
2. Handstrap and tethered stylus  
3. Handstrap Clip  
Tool Required: Phillips #1 screwdriver (not supplied)  
1. Place the MX7 Tecton with the screen facing down, on a flat stable surface.  
2. Attach the handstrap retainer bracket to the MX7 Tecton with the screws and washers provided.  
3. Slip the Handstrap Clip into the bracket at the base of the MX7 Tecton.  
4. Making sure the closed loop fastener surfaces on the handstrap are facing up, slide the strap through the pin in the bottom  
bracket and the clip.  
5. Fold each end of the strap over so that the closed loop fastener surfaces mate evenly.  
6. Test the strap's connection making sure the MX7 Tecton is securely connected to each end of the handstrap's connectors.  
Check the closed loop fastener, retainer bracket and clip connections frequently. If they have loosened, they must be tightened  
or replaced before the MX7 Tecton is placed into service again.  
2 - 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Attaching the Trigger Handle  
Either the trigger handle or the handstrap is attached, not both. Honeywell recommends that, in the absence of a trigger handle,  
the handstrap be used at all times.  
Pressing the trigger on the trigger handle activates the integrated scanner and functions the same as the Scan button on the  
keypad. With the trigger handle installed the Scan key on the keypad remains active. A trigger press duplicates the Scan button  
press operation.  
The handle is built of a durable, flexible plastic.  
The handle will not detach from the MX7 Tecton if the unit is dropped.  
The trigger handle is a mechanical device. Battery or external A/C power is not  
required for operation.  
The trigger handle does not need to be removed when replacing the main battery  
pack.  
The trigger handle might also be called a pistol grip.  
Tool required: Torque wrench capable of torquing to 3 1 in/lb (.34 .11 N/m).  
1. Place the MX7 in Suspend.  
2. Place the MX7 Tecton with the screen facing down, on a flat stable surface.  
3. Remove the handstrap, if installed. Tool required: Phillips #1 screwdriver.  
4. Remove the main battery.  
5. Slide the locking tab on the underside of the trigger handle into the slot at the back of the battery compartment and press it  
firmly into place.  
6. Ensure that the main battery can be inserted into the battery compartment before securing the trigger handle in place.  
7. Attach the trigger handle to the MX7 Tecton (as shown above) with the screws provided.  
8. Torque the pan head screws to 3 1 in/lb (.34 .11 N/m).  
9. Secure the strap tether to the trigger handle.  
10. Place the stylus in the stylus holder in the bottom of the trigger handle. Tie the stylus tether to the stylus and the trigger  
handle.  
Periodically check the trigger handle for wear and the connection for tightness. If the handle gets worn or damaged, it must be  
replaced. If the trigger handle connection loosens, it must be tightened or replaced before the MX7 Tecton is placed back in ser-  
vice.  
2 - 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Assembling the Carry Case  
Note: Accessory installation or removal should be performed on a clean, well-lit surface. When necessary, protect the work  
surface, the MX7 Tecton, and components from electrostatic discharge.  
The main battery can be removed and inserted without taking the MX7 Tecton out of the carry case.  
1. Remove any cables connected to the I/O port at the bottom of the MX7 Tecton.  
2. Remove the rubber boot from the MX7 Tecton.  
3. Separate the hook and loop fabric on the carry case without removing the hook and loop fabric from the carry case.  
4. Slip the removable, clear plastic protector for the keypad and touch screen into the case. Position it against the openings for  
the keypad and touch screen in the carry case. The voice case does not require the clear plastic protector.  
5. Slide the MX7 Tecton into the case, making sure the touch screen and keypad (including the Scan LED) are visible and  
accessible through the front openings of the case.  
6. Securely tether the stylus to the case, if necessary. Place the stylus in the stylus holder on the handstrap or in the trigger  
handle.  
7. Loosen then tighten the handstrap (on cases without a trigger handle opening) until the carry case assembly is secure in  
your hand.  
8. When a shoulder strap is available, secure the clips at each end of the shoulder strap to the D rings on either side of the  
carry case. The shoulder strap allows the MX7 Tecton to hang upside down until needed.  
Carry Case with Metal Snaps  
The metal snap has a bulge in the lip and a dot indentation on the opposite side. To close the carry case, tuck the lip bulge  
under the snap lip and press on the dot to snap closed.  
Pull the snap up to open the carry case.  
Connecting a Headset Cable  
The headset consists of an earpiece, a microphone, a clothing clip and a cable. The headset attaches to the audio cable end of  
the voice cable which attaches to the MX7 Tecton.  
When the headset is cabled to the MX7 Tecton, the microphone and speaker on the front of the device are automatically dis-  
abled.  
1. Microphone  
2. Headphones  
3. Connects to voice cable end of voice  
cable  
2 - 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
2
Voice Cable  
1. Connect to MX7 Tecton I/O port  
2. Connect to Headset Cable  
1
1. Connect the MX7 Tecton voice cable I/O connector to the I/O port on the MX7 Tecton.  
2. Slide the voice cable ends of the headset assembly and the voice cable together until they click shut. Do not twist or bend  
the connectors.  
3. Adjust the headset and microphone. Use the clothing clip to secure the cable to your clothing.  
Adjusting Headset / Microphone and Securing the Cable  
Do not twist the microphone boom when adjusting the microphone. The microphone should be adjusted to be about two fin-  
ger widths from your mouth.  
Make sure the microphone is pointed at your mouth. Note the small “Talk” label near the mouthpiece. Make sure the Talk  
label is in front of your mouth. The microphone cable can be routed over or under clothing.  
Under Clothing  
Leave the cable exposed only at the top of the collar.  
Be sure to leave a small loop of cable to allow movement of your head.  
Over Clothing  
Use clothing clips to hold the cable close to your body.  
Tuck the cable under the belt, but leave a small loop where it goes under the belt.  
Do not wear the cable on the front of your body. It may get in your way or get caught on protruding objects.  
2 - 20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Connecting the USB Client and Power Cable  
Note: AC/DC Adapter must be assembled before this process begins.  
Note: Do not connect AC power to the AC Adapter until instructed in the following procedure.  
Insert A/C  
Adapter Cable  
Connect to Input/  
Output Port  
Connect to USB  
client port  
1. Holding the cable I/O connector, pinch the catch release buttons in until the catches are open. Connect the cable to the  
MX7 Tecton I/O port by matching the shape of the I/O connector on the cable with the shape of the I/O connector at the  
base of the MX7 Tecton. Release the catch release buttons.  
2. Insert the AC adapter single pin cable.  
3. Connect the AC Adapter to an indoor power source (wall outlet).  
4. Insert the USB client plug into the target USB Client port. The MX7 Tecton and the USB client are connected.  
Connecting the Serial and Power Cable  
Note: AC/DC Adapter must be assembled before this procedure begins.  
Note: Do not connect AC power to the AC Adapter until instructed in the following procedure.  
Insert A/C  
Adapter Cable  
Connect to Input/  
Output Port  
Connect to Serial  
client port  
1. Holding the cable I/O connector, squeeze the catch release buttons in until the catches are open. Connect the cable to the  
MX7 Tecton I/O port by matching the shape of the I/O connector on the cable with the shape of the I/O connector at the  
base of the MX7 Tecton. Release the catch release buttons.  
2. Connect the AC adapter single pin cable.  
3. Connect the assembled AC/DC Adapter to an indoor power source (wall outlet).  
4. Connect the RS232 cable end to the desired serial device. Turn the thumbscrews clockwise until the connection is finger-  
tight. The MX7 Tecton and the serial device are connected.  
2 - 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Assembling the AC/DC Power Supply  
1. Connects to multi-purpose cables con-  
nected to the I/O port on the MX7 Tec-  
ton  
2. AC receptacle  
3. Wall plug  
4. AC connection from wall to adapter  
To apply external power to the MX7 Tecton follow the steps below in sequence.  
1. Plug the 3 prong AC adapter cable end into an indoor AC power source (e.g., wall outlet).  
2. Firmly press the female end of the power cable into the male connector on the power adapter. When AC power is being  
supplied to the power adapter, the LED on the power adapter illuminates green. The AC adapter is ready for use.  
3. Squeeze the catches of the (USB/Power or Serial/Power) I/O connector and push the cable connector into the MX7 Tecton  
I/O port until it clicks. The click means the connector is seated firmly.  
4. Press the power cable connector pin from the AC adapter into the connector on the (USB/Power or Serial/Power) cable  
attached to the base of the MX7 Tecton. External power is now being supplied to the MX7 Tecton.  
Whenever possible, use the AC power adapter with the MX7 Tecton to conserve the main battery power and maintain a charge  
in the internal battery.  
2 - 22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Startup Help  
Issue:  
Can’t change the date/time or adjust the volume.  
Solution:  
AppLock is installed and may be running in User Mode on the MX7 Tecton. AppLock user mode restricts access to the con-  
trol panels.  
Issue:  
Touch screen is not accepting stylus taps or needs recalibration.  
Solution:  
If the touch screen is not accepting stylus taps, press Ctrl+Esc (Blue+Alt) to force the Start Menu to appear. Use the arrow  
keys to move from program to program. Press Enter to open folders or start a program e.g., Registry panel Warmboot but-  
ton.  
Issue:  
The MX7 Tecton seems to lockup as soon as it is rebooted.  
Solution:  
There may be slight delays while the wireless clients connect to the network, authorization for voice-enabled applications  
complete, Wavelink Avalanche management of the MX7 Tecton startup completes, and Bluetooth relationships establish or  
re-establish. When the desktop appears or an application begins, the MX7 Tecton is ready for use.  
Issue:  
New MX7 Tecton main batteries don't last more than a few hours.  
Solution:  
New batteries must be fully charged prior to first use. Li-Ion batteries (like all batteries) gradually lose their capacity over  
time (in a linear fashion) and never just stop working. This is important to remember – the MX7 Tecton is always ‘on’ even  
when in the Suspend state and draws a small amount of battery power at all times.  
Cold Storage Battery Life – minimum 2.5 hours while the unit is roaming, powered on with ambient temperature -10°C  
(14°F) or above, display backlight turned on, keypad LED backlight on, radio connected to Access Point, and scanner  
decoding bar codes. The Li-Ion main battery (MX7A381BATT, MX7393BATT, and MX7396BATTERY) has been designed  
specifically for the Cold Storage device. This 1250mAh battery has a blue label while the standard 2200mAh battery has a  
white (MX7A380BATT and MX7392BATT) label.  
Issue:  
Keep losing ActiveSync connection between my host computer and the MX7 Tecton.  
Solution:  
Disconnect the USB cable, wait 1-2 seconds and reconnect the cable. The MX7 Tecton will not enter Suspend as long as  
an ActiveSync session is running. The ActiveSync session prevents it from going into suspend.  
2 - 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2 - 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
Hardware Configuration  
System Hardware  
802.11 a/b/g Wireless Client  
The MX7 Tecton has an 802.11 network card that supports diversity with two internal antennas. The CPU board does not  
allow hot swapping the network card. WEP, WPA and LEAP are supported.  
Central Processing Unit  
The CPU is an 806MHz Marvell PXA-320 CPU. The OS image is stored in internal flash and is loaded into RAM for execu-  
tion. Turbo mode switching is supported and turned on by default.  
The MX7 Tecton supports the following I/O components of the core logic:  
One SD card slot under the main battery pack.  
One serial port.  
One Digitizer Input port (Touch screen).  
Program CAB files, MX7 Tecton utilities, wireless drivers, the registry and registry backup information are stored in internal  
Flash.  
System Memory  
The CPU configuration supports 256MB on-board flash. The system optimizes for the amount of RAM available.  
Internal flash is used for boot loader code and system low-level diagnostics code. Bootloader code is validated at system  
startup.  
Internal SD Card Slot  
One SD Memory card slot for Expansion Memory, located in the main battery well, and protected by a rubber flap. 1GB and  
4GB flash memory cards are available from Honeywell.  
3 - 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Video Subsystem  
The touch screen is a 3.5” (8.9 cm) diagonal viewing area, ¼ VGA 320 by 240 pixel TFT Reflective Active Color LCD. Back-  
lighting is available and can be turned on and off with key sequences. The turn-off timing is configured through the Start >  
Settings > Control Panel > Display icon. The display controller supports Microsoft CE 6 graphics modes.  
A touch screen allows mouse functions (tapping on the display or signature capture) using a stylus. The touch screen has  
an actuation force with finger less than 100 grams. The color display has an LED backlight and is optimized for indoor use.  
The display appears black when the MX7 Tecton is in Suspend Mode.  
Power Supply  
The MX7 Tecton uses one of two batteries for operation.  
Main Battery. A rechargeable 2200 mAh Lithium-Ion (Li-Ion) battery pack. The battery pack recharges while in the MX7  
Tecton when the device is connected to the optional external MX7 Tecton AC/DC power source. The main battery pack  
can be removed from the MX7 Tecton and inserted in the MX7 Tecton Battery Charger which simultaneously charges up  
to four battery packs in four hours. A new main battery pack can be fully charged in 6 hours when it is in an MX7 Tecton  
connected to AC power and 3.5 hours when it is in the MX7 Tecton battery charger.  
Low temperature. A rechargeable Lithium-Ion (Li-Ion) battery pack has a 1250 mAh capacity.  
Super-capacitor (Super-cap). No backup “battery” is used. Super-cap internal battery maintains RAM and other vital  
settings during a critical shutdown.  
Note: An uninterrupted external power source (wall AC adapters) transfers power to the MX7 Tectons internal charging  
circuitry which, in turn, recharges the main battery and Super-cap battery. Frequent connection to an external power  
source, if feasible, is recommended to maintain main battery charge status as the Super-cap battery cannot be  
recharged by a dead or missing main battery.  
COM Ports  
The MX7 Tecton has one mini D 20-pin serial port (a multifunction I/O port) that can be configured by the user. It has a  
power input interface to allow powering the MX7 Tecton from an external source (AC/DC power supply or vehicle power).  
The power input interface range is 10 - 18VDC.  
RS232 Serial Port  
Configured as COM1. Bi-directional full duplex and supports data rates up to 115 Kb/s. The port does not have RI or CD  
signals nor does it support 5V switchable power on pin 9 for tethered scanners. The serial port driver supports full duplex  
communications over the serial port. It supports data exchange via ActiveSync, but does not automatically start ActiveSync  
when connected. The Cable, Multipurpose RS232 and Power and the Adapter, RS232 PC port to D9 male accessories can  
be used with the RS232 serial port. External AC power is available when the multipurpose RS232/Power cable is con-  
nected. External AC power is not available for the Adapter, RS232 PC port to D9 male option. Power is drawn from the main  
battery pack when this adapter is connected..  
USB Client Port  
The MX7 Tecton has one USB Client port for ActiveSync applications. An accessory USB cable, Cable, Multipurpose USB  
and Power is available to connect the MX7 Tecton to a USB Type A plug on a PC for ActiveSync functions. External AC  
power is available when the multipurpose USB Client/Power cable is connected.  
Audio Connection  
An audio headset interface is available using the Adapter, Audio accessory with the I/O port. The connection cable con-  
nects the MX7 Tecton to a Voxware quick disconnect 4-pin interface. This cable adapts to specific styles of headsets for  
voice input, stereo or mono output. The MX7 Tecton with a Summit Client supports mono only. A 3-wire connector with (at  
a minimum) connections for ground, microphone, and 1 speaker. Connecting the headset to the MX7 Tecton COM port  
turns off audio output to the MX7 Tecton speaker on the front of the device. All sounds previously directed to the speaker  
are redirected to the headphone, including beeps. Bias voltage for an electric condenser microphone is available. External  
AC power is not available for this option. Power is drawn from the main battery pack.  
3 - 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Audio Support  
Speaker  
The speaker supplies audible verification signals normally used by the Windows operating system. The speaker is  
located on the front of the MX7 Tecton, above the MX7 Tecton logo. The mobile device emits a Sound Pressure Level  
(loudness) of at least 102 dB measured as follows:  
Frequency: 2650 + 100 Hz  
Distance: 10 cm on axis in front of Speaker opening in front of unit.  
Duration: Continuous 2650 Hz tone.  
The default is 1 beep for a good scan and 2 beeps for a bad scan.  
Volume Control  
Volume control is managed by a Windows control panel, an API and the Orange-Scan up/down arrow key sequence.  
Voice  
All Microsoft-supplied audio codecs are included in the OS image. The hardware codecs, the input and output analog  
voice circuitry and the system design are designed to support voice applications using a headset connected to the  
Adapter, Audio accessory cable and the MX7 Tecton I/O connector.  
Scanner / Imager Port  
The MX7 Tecton has one integrated bar code scanner/imager port. Only one scan engine is installed at a time. Scan  
engines are not “hot swappable”. The MX7 Tecton may have one of the following bar code decoding engines:  
Short Range Laser Scanner, SE955I  
Base Laser Scanner, SE955E  
Multi-Range “LORAX” Laser, SE1524ER  
Hand Held Products 2D Area Imager, 5300  
Honeywell Laser Scanner, N43XX  
Honeywell Laser Scanner, N73XX  
Note: 955E does not support aim mode. Any attempt to adjust the aiming beam using 955E programming bar codes will  
fail. The Base Laser scanner does not decode Codablock, Code93i or Telepen symbologies.  
The integrated scan engine activates when the Scan button on the front of the MX7 Tecton is depressed or when the trigger  
on an installed trigger handle is depressed. The Data Collection application is available to set scanner/imager options.  
Functionality of the integrated scan engine driver is based on the decoder driver version installed in the MX7 Tecton. Func-  
tions may include audible tones on good scan (at the maximum dB supported by the speaker), failed scan, Scan LED indi-  
cation of a scan in progress, among other functions. If enabled, a vibration device provides a tactile response on a good  
scan event.  
Bluetooth EZPair (or LXEZ Pairing)  
The MX7 Tecton contains Bluetooth version 2.1 with Enhanced Data Rate (EDR). Bluetooth device connection (or pairing)  
can occur at distances up to 32.8 ft (10 meters) Line of Sight. The wireless client retains network connectivity while Blue-  
tooth is active and the paired device is within range.  
The user will not be able to select PIN authentication or encryption on connections from the MX7 Tecton. However, the MX7  
Tecton supports authentication requests from pairing devices. If a pairing device requests authentication or encryption, the  
MX7 Tecton displays a prompt for the PIN or passcode. Maximum encryption is 128 bit. Encryption is based on the length  
of the user’s passcode.  
Bluetooth devices can be paired and managed using the EZPair (or LXEZ Pairing) control panel.  
The MX7 Tecton does not have a Bluetooth managed LED.  
The LED on a mobile Bluetooth scanner illuminates during a scanning operation; the Scan LED on the MX7 Tecton does  
not illuminate.  
Bar code data captured by a mobile Bluetooth scanner is manipulated by the settings in the Data Collection control panel.  
Multiple beeps may be heard during a bar code scan using a mobile Bluetooth scanner; beeps from the mobile Bluetooth  
scanner as the bar code data is accepted/rejected, and other beeps from the MX7 Tecton during final bar code data  
manipulation.  
3 - 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Keypads  
55 Key Keypads  
Del  
BkSp  
ANSI Primary Delete  
ANSI Primary Backspace  
5250 Primary Delete  
Using the 55 Key Alpha-Numeric Keypad  
There are three options available for the 55 key keypad:  
2. 55 Key 5250 Alphanumeric KeyMap - Primary Delete (page 12-6). 5250 commands are displayed on the key-  
pad overlay next to the affected keys.  
3. 55 key Alphanumeric Keymap - Primary Backspace (page 12-11). This keypad resembles the ANSI Primary  
Delete keypad with the exception that the Del key function on the ANSI Primary Delete keypad is replaced by  
the BkSp key function.  
Del  
BkSp  
When using a sequence of keys that includes a sticky key, press the sticky key first, release it, then press the  
rest of the key sequence.  
When using a sequence of keys that includes the Orange or Blue keys, press the color key first then the rest of  
the key sequence.  
Alphabetic keys default to lower case letters. Press the Shft key, then the alphabetic key for an uppercase letter.  
When the computer boots, the default condition of Caps (or CapsLock) is Off. The Caps (or CapsLock) condition  
can be toggled with Blue plus Tab key sequence.  
3 - 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
32 Key Keypad  
Triple Tap Alpha  
Using the 32 Key Numeric with Triple Tap Alpha  
When using a sequence of keys that require an alpha key, first press the Alph key. Use the Shft sticky key or  
the Caps key sequence (Blue+Tab) for upper case alphabetic characters. See 32 key Numeric-Alpha Keymap  
Pressing the Alph key forces “Alpha” mode for the 2,3,4,5,6,7,8, and 9 keys. The 1 and 0 keys continue to place  
a 1 and 0 into the text field.  
To create a combination of numbers and letters before pressing Enter, tap the Alph key to toggle between Alpha  
and Numeric mode.  
When using a sequence of keys that do not include the Alph key but does include a sticky key, press the sticky  
key first then the rest of the key sequence.  
3 - 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Display  
The touch screen display is an active color LCD unit capable of supporting VGA graphics modes. Display size is 240 x 320  
pixels in portrait orientation. The covering is designed to resist stains. The touch screen allows signature capture and touch  
input. A pen stylus is included. The touch screen responds to an actuation force (touch) of 4 oz. of pressure (or greater).  
The color display is optimized for indoor lighting. The display is black when the device is in Suspend Mode or when both  
batteries have expired and the unit is Off.  
Display Backlight Timer  
When the Backlight Timer expires the display backlight is turned off. The default value for the battery power timer is 3  
seconds. The default value for the external power timer is “never” and the check box is blank. The backlight timer dims  
the backlight on the touch screen and the keypad at the end of the specified time. When the display wakes up, the  
Backlight timer begins the countdown again. The keypad backlight can be synchronized with the display backlight  
activity.  
Status LEDs  
The MX7 Tecton does not have a Bluetooth managed LED. Bluetooth activity indicators are located in the taskbar.  
System Status LED is located at the top left of the keypad, above the Scan button.  
The Scan Status LED is located below the keypad.  
The Alpha Mode LED is located below the F4 key on the 32-key keypad (Numeric-Alpha keypad).  
LED  
Color - Activity Indicates ...  
System Status Red - Blinking  
Power fail. Replace the main battery with a fully charged main battery.  
Or  
Connect the MX7 Tecton to external AC power then replace the main battery with a fully  
charged main battery.  
Red - Steady  
Main Battery Low. If the main battery is not replaced with a fully charged battery before  
the main battery fails, the MX7 Tecton is turned Off.  
Green - Blinking Display Off. No user intervention required.  
No Color  
MX7 Tecton is either full on - with the display on (backlights may be dimmed when the  
status LED has no color) or in Suspend - with the display off.  
Scan Status  
Green - Steady  
Red – Steady  
No color  
Good scan.  
Scan in progress.  
Integrated Scanner / Imager ready for use.  
Bar code decoder engine is storing changed parameters.  
MX7 Tecton 32-key is in Alpha character input mode.  
MX7 Tecton 32-key is in Numeric key input mode.  
Amber - Steady  
Green - Steady  
No color  
Alpha Mode  
(Alph LED)  
Cold Storage Configuration  
MX7 Tecton 1250mAh Cold Storage battery has a blue label.  
Snowflake decal above the MX7 Tecton keypad.  
Heating element visible on the touch screen and the scan aperture.  
Cold storage battery is recharged in the MX7 Tecton Battery Charger, MX7 Tecton Desk Cradle and when in an MX7 Tecton  
attached to an external power source (e.g., AC adapter).  
The Cold Storage version is designed to operate normally when reading bar codes and moving from, and into, cold storage  
warehouses, freezers and vehicles where the temperatures may vary between -30°C and 5°C (-22°F and 41°F).  
Cold Storage Battery  
There is no change in the way the Cold Storage battery is inserted into and removed from the MX7 Tecton battery well.  
Battery Life – minimum 2.5 hours while the unit is roaming, powered on with ambient temperature -10°C (14°F) or  
above, Display backlight turned on, Keypad LED backlight on, radio connected to Access Point, and scanner decoding  
bar codes.  
3 - 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
The Li-Ion main battery (MX7A381BATT and MX7393BATT) has been designed specifically for the Cold Storage  
device. This 1250mAh battery has a blue label while the standard MX7 Tecton 2200mAh battery has a white  
(MX7A380BATT and MX7392BATT) label.  
Snowflake Decal  
A Cold Storage device has a snowflake decal between the touch screen and the keypad. The decal is located to the left  
when the screen is facing forward.  
Heating Elements  
Heating elements activate when ambient temperature drops below 0°C (32°F). Using the stylus when performing  
screen touch functions is recommended. There may be some condensation as the Cold Storage device moves in and  
out of cold storage areas. The condensation on the touch screen and the scan aperture quickly dissipates.  
The touch screen heating elements and scanner aperture heating elements may be visible when the Cold Storage  
device is tilted slightly. No user interaction is required to turn the heating elements on/off. Stylus taps on the touch  
screen function normally. Due to the heating element overlaying the scan aperture, bar code scanning may require the  
user to move the scan aperture closer to the bar code for good scan results.  
Recharging Cold Storage Batteries  
The Cold Storage battery pack can be recharged to full capacity while in a Cold Storage MX7 Tecton connected to an  
external power source and also while the Cold Storage battery pack is inserted in the charging bay in a powered MX7  
Tecton cradle. The battery pack temperature must be above 10°C (50°F) before re-charging can begin.  
Battery packs in the Battery Charger begin charging when the battery pack temperature is between 10°C (50°F) and  
40°C (100°F).  
To charge the Cold Storage battery pack to full capacity, the Battery Charger firmware must be V1.07 or greater. The  
firmware version is noted on the battery charger label on the bottom of the charger.  
Contact Product Service and Repair (page 16-1) if your battery charger firmware needs to be upgraded.  
The Battery Charger and AC adapter are not designed to operate in a freezer or cold storage environment.  
Hot-swapping the Cold Storage Battery  
The Cold Storage mobile device, with a fully charged Super-cap battery, retains data during a main battery hot-swap at  
-30°C (-22°F) for at least 90 seconds. The temperature of the fully charged replacement Cold Storage main battery  
must be +10°C (14°F), or above.  
Normal Operation Temperature Ranges  
In the freezer where the temperature ranges between –30°C to -18°C (-22°F to 0°F).  
In the loading dock where temperature ranges between 0°C to 5°C (32°F to 41°F) with the relative humidity at 65%  
Moving between the freezer and a loading/unloading area where the temperature transitions from -30°C to 5°C (-  
22°F to 41°F).  
3 - 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
3 - 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
Power Modes and Batteries  
Power Modes  
The MX7 Tecton has three power modes: On, Suspend and Off.  
On Mode  
The Display  
When the display is On:  
the keypad, touch screen and all peripherals function normally  
the display backlight is on until the Backlight timer expires  
The MX7 Tecton  
After a new MX7 Tecton has been received, a charged main battery inserted, and the Power key tapped, the MX7 Tecton is  
always On until both batteries are drained completely of power.  
When the main battery and Super-cap battery are drained completely, the unit is in the Off mode. The unit transitions from  
the Off mode to the On mode when a charged main battery is inserted or external power is applied and the Power key is  
pressed.  
Suspend Mode  
The Suspend mode is entered when the unit is inactive for a predetermined period of time or the user taps the Power key.  
MX7 Tecton Suspend timers are set using Windows control panels.  
Wake-up Events - all configurable via a Power Management API call:  
Any key on the keypad  
Stylus touch on the touch screen  
Handle trigger press  
Connecting to AC adapter  
Power button tap  
USB connection  
COM port control CTS  
Real time clock  
Bluetooth device reconnect / disconnect message  
When the MX7 Tecton wakes up, the Display Backlight and the Power Off timers begin the countdown again. When any one  
of the above events occurs prior to the Power Off timer expiring, the timer starts the countdown again. The MX7 Tecton  
does not need to be placed in Suspend mode before hotswapping the main battery.  
Off Mode  
The unit is in Off Mode when the main battery and the Super-cap battery are depleted. Insert a fully charged main battery  
and press the Power key to turn the MX7 Tecton On.  
4 - 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Batteries  
The MX7 Tecton is designed to work with a Lithium-Ion (Li-ion) battery. Under normal conditions it should last approximately  
eight to ten hours before requiring a recharge. The more you use the scanner or the wireless transmitter, the shorter the time  
required between battery recharges.  
A suspended MX7 Tecton maintains settings for a minimum of two days using a main battery that has reached the Low Warning  
point and a fully charged Super-cap internal battery. The MX7 Tecton retains data, during a main battery hot swap, for at least 5  
minutes.  
Note: New main battery packs must be charged prior to use. This process takes up to four hours in an MX7 Tecton Battery  
Charger and six hours when the MX7 Tecton is connected to external power.  
Checking Battery Status  
Tap the Battery tab on the Power panel. Battery level, power status and charge remaining is displayed.  
Note: When the Battery control panel is displayed power management is disabled, meaning the backlights and display will  
not turn off nor will the unit suspend, after the configured inactivity times expire.  
Main Battery Pack  
The main battery pack has a rugged plastic enclosure that is designed to withstand the ordinary rigors of an industrial envi-  
ronment. Exercise care when transporting the battery pack making sure it does not come in contact with excessive heat or  
any power source other than the MX7 Tecton Battery Charger or the MX7 Tecton unit.  
When the main battery pack is properly installed in the unit it provides up to eight hours of operation depending upon use  
and accessories installed. The battery pack is resistant to impact damage and falls of up to four feet to a concrete surface.  
Under normal conditions it should last approximately eight hours before requiring a recharge. The more you use the scan-  
ner or the wireless transmitter, the shorter the time required between battery recharges.  
Battery Hotswapping  
Note: When the internal battery power is Low or Very Low (can be viewed on the Power control panel) connect the AC  
adapter to the MX7 Tecton before replacing the main battery pack.  
When the main battery power level is low, the MX7 Tecton will signal the user with the low battery warning indicator (the  
Status LED remains a steady red) that continues until the main battery is replaced, the battery completely depletes, or  
external power is applied to the MX7 Tecton using an AC Adapter.  
You can replace the main battery by first placing the MX7 Tecton in Suspend Mode then removing the discharged main bat-  
tery and installing a charged main battery within a five minute time limit (or before the Super-cap internal battery depletes).  
When the main battery is removed the MX7 Tecton enters Critical Suspend state; the MX7 Tecton remains in Suspend  
mode, the display is turned off and the internal battery continues to power the unit for at least five minutes.  
Though data is retained, the MX7 Tecton cannot be used until a charged main battery is installed. After installing the new  
battery, press the Power key. Full operational recovery from Suspend can take several seconds while the client is re-estab-  
lishing a network link. If the internal battery depletes before a fully charged main battery can be inserted, the MX7 Tecton  
will turn Off.  
Low Battery Warning  
It is recommended that the main battery pack be removed and replaced when its energy depletes. When the main battery  
Low Battery Warning appears (the Status LED remains a steady red) perform an orderly shut down, minimizing the opera-  
tion of any installed devices and insuring any information is saved that should be saved.  
Super-cap Internal Battery  
The MX7 Tecton has an internal battery that is designed to provide limited-duration electrical power in the event of main  
battery failure. The energy needed to maintain the internal battery near full charge at all times is drawn from the MX7 Tec-  
ton main battery. It takes 5 minutes or less to fully charge the internal battery. The duration of internal battery life is depen-  
dent upon operation of the MX7 Tecton, its features and any operating applications. The internal battery has a minimum  
service life of two years. The Super-cap internal battery is replaced by Honeywell.  
4 - 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Handling Batteries Safely  
Never dispose of a battery in a fire. This may cause an explosion.  
Do not replace individual cells in a battery pack.  
Do not attempt to pry open the battery pack shell.  
Be careful when handling any battery. If a battery is broken or shows signs of leakage do not attempt to charge it. Dispose  
of it using proper procedures.  
Caution  
Nickel-based cells contain a chemical solution which burns skin, eyes, etc. Leakage from cells is the only possible way for  
such exposure to occur. In this event, rinse the affected area thoroughly with water. If the solution contacts the eyes, get  
immediate medical attention.  
NiMH and Li-Ion batteries are capable of delivering high currents when accidentally shorted. Accidental shorting can occur  
when contact is made with jewelry, metal surfaces, conductive tools, etc., making the objects very hot. Never place a bat-  
tery in a pocket or case with keys, coins, or other metal objects.  
4 - 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4 - 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
Software Configuration  
Introduction  
There are several different aspects to the setup and configuration of the MX7 Tecton. Many of the setup and configuration set-  
tings are dependent upon the optional features such as hardware and software installed on the mobile device. The examples  
found in this section are to be used as examples only, because the configuration of your specific MX7 Tecton may vary. The fol-  
lowing sections provide a general reference for the configuration of the MX7 Tecton and some of its optional features. Contact  
Technical Assistance (page 16-1) for information on the latest upgrades.  
Windows Mobile  
Note: For general use instruction, refer to commercially available Windows Mobile user’s guides or the Windows Mobile on-line  
Help application in the MX7 Tecton  
This section’s contents assumes the system administrator is familiar with Microsoft Windows options and capabilities loaded on  
most standard Windows desktop computers.  
Therefore, the sections that follow describe only those Windows capabilities that are unique to the MX7 Tecton and its Windows  
Mobile environment.  
Installed Software  
Note: Some options require an external modem connection. Modems are not available from Honeywell.  
When you order an MX7 Tecton you receive the software files required by the separate programs needed for operation and wire-  
less client communication. The files are loaded and stored in folders in the mobile device.  
This section lists the contents of the folders and the general function of the files. Files installed in each MX7 Tecton are specific  
to the intended function of the MX7 Tecton.  
Files installed in mobile devices that are configured for a wireless environment usually contain a radio specific driver – the driver  
for the radio is specific to the manufacturer of the radio installed in the wireless host environment and is not interchangeable.  
Software Load  
The software loaded on the MX7 Tecton computer consists of Windows Mobile Operating System, hardware-specific OEM  
Adaptation Layer, device drivers, Internet Explorer for Windows Mobile browser and MX7 Tecton-specific utilities. The soft-  
ware supported by the MX7 Tecton is summarized below:  
Operating System - Full Operating System License: Includes all operating system components, including Windows  
Mobile kernel, file system, communications, connectivity (for remote APIs), device drivers, events and messaging,  
graphics, keyboard and touch screen input, window management, and common controls.  
Network and Device Drivers  
Bluetooth (Option)  
AppLock (Option)  
RFTerm (VT220, TN5250, TN3270) Terminal Emulation (Option).  
CE API Routines  
Software Backup  
Application programs and data that are normally RAM resident are backed up via ActiveSync.  
Version Control  
Version numbers are applied to the boot loader and the OS image independently. The version information stored consists of  
the build number, plus the date and time of compile (in lieu of a build number). These version numbers are stored in non-  
volatile storage, where the user cannot inadvertently modify them. A Settings panel and API are provided so the user can  
reference the version numbers for support purposes.  
The MX7 Tecton has a unique 128-bit ID code as required by the Windows Mobile specification. This ID number is gener-  
ated by the boot loader. This ID code is available in the About Info settings panel, and via a Win32 standard API.  
5 - 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
             
In addition, an API is provided to return a standard copyright string, so that applications may reference this to be sure they  
are running on a Honeywell mobile device for licensing purposes.  
Boot Loader  
The MX7 Tecton supports a proprietary boot loader. It is the responsibility of the boot loader to:  
Initialize all system hardware  
Initiate OS startup  
Handle wakeup from system suspend, loading saved state  
The MX7 Tecton re-starts the OS during warmboot and restart.  
Startup Folders and Launch Sequences  
The MX7 Tecton operating system uses two startup folders:  
User applications placed in the Windows\Startup folder automatically run during a reboot. They are deleted upon a clean  
boot.  
User applications placed in the System folder automatically run during a reboot.  
Software Development  
The CE API Programming Guide documents CE API calls for the MX7 Tecton. It is intended as an addition to the standard Mic-  
rosoft Windows Mobile API documentation.  
A Software Developers Kit (SDK) and additional information about software development can be found on the Developer Portal.  
Contact Technical Assistance (page 16-1) for more information.  
Today Screen  
For general use instruction, refer to commercially available Windows Mobile user guides or the Windows Mobile on-line Help on  
the MX7 Tecton.  
The main screen for the MX7 Tecton is known as the Today screen. The Today screen shows various options and status icons.  
The Today screen appearance can be configured using the Today (page 5-22) control panel. Both the appearance of the Today  
screen and the items displayed may be configured.  
1. Start menu  
2. Configurable Today screen listing  
3. Notification Bar  
4. Status icons  
5. Soft Keys  
5 - 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Start Menu  
The Start menu consists of applications and folders.  
Selecting an application from the menu starts that application.  
Selecting a folder opens a window displaying the contents of the folder.  
Selecting Settings displays the Settings panels by category.  
Selecting Help displays context sensitive help. The contents displayed in the help window vary depending on the screen  
displayed before Help was accessed.  
Programs not appearing on the Start menu can be accessed by using the File Explorer.  
Configurable Today Screen Listing  
The items displayed in the Today screen listing can be configured from Start > Settings > Today > Items. For more infor-  
mation, see Today (page 5-22) settings later in this chapter.  
Date  
When the Date is enabled to display on the Today screen, the date is displayed on the left side of the screen and the time is  
displayed on the right side. If there are any alarms set, a bell icon is displayed under the current time. For more information,  
Device Unlocked / Device Locked  
When the MX7 Tecton is unlocked, tapping on Device unlocked locks the MX7 Tecton.  
When the MX7 Tecton is locked, tapping on Unlock at the bottom of the screen unlocks the MX7 Tecton. Depending on the  
settings, a password may be required. The MX7 Tecton can also be configured to lock after a period of inactivity. For more  
information, see the Lock (page 5-16) settings.  
Notification Bar  
The Notification Bar is displayed at the top of the Today screen. The notification bar remains visible even when other  
screens are selected, though the icons displayed may vary.  
When the Notification bar is displayed on other screens there may be an X (close the current screen/program) or an ok  
(accept the current input and close the screen).  
Category  
Icon Function  
Network  
The Windows Mobile Wireless Manager is managing the wireless connection and the MX7  
Tecton is connected to a wireless network.  
Network  
Network  
Network  
Volume  
Volume  
Volume  
Power  
A wireless manager is managing the wireless connection.  
A wireless manager is managing the wireless connection and has detected one or more wire-  
less networks in range.  
A wireless manager is managing the wireless connection and has not detected a wireless net-  
work in range.  
The speaker is on.  
The speaker is off.  
Vibrate is on.  
The MX7 Tecton is connected to external power.  
Power  
The MX7 Tecton is operating on battery power. The strength of the battery is indicated by the  
number of bars displayed: 0 (low battery) to 4 (fully charged battery).  
5 - 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Status Icons  
Additional icons may be displayed at the lower edge of the Today screen.  
Note: Summit signal strength icons are displayed only when the Summit Client Utility is controlling the radio.  
Icon Function  
MX7 Tecton is connected to one or more of the targeted Bluetooth device(s).  
MX7 Tecton is not connected to any Bluetooth device.  
MX7 Tecton is ready to connect with any Bluetooth device.  
MX7 Tecton is out of range of all paired Bluetooth device(s). Connection is inactive.  
Summit radio is not currently associated or authenticated to an Access Point.  
The signal strength for the currently associated/authenticated Access Point is less than -90 dBm  
The signal strength for the currently associated/authenticated Access Point is -71 dBm to -90 dBm  
The signal strength for the currently associated/authenticated Access Point is -51 dBm to -70 dBm  
The signal strength for the currently associated/authenticated Access Point is greater than -50 dBm  
More information on Bluetooth activity and settings can be found in Bluetooth Configuration (page 7-1).  
Soft Keys  
Soft Keys are displayed at the bottom of the Today screen. The keys displayed vary by the active screen/application.  
The soft keys generally provide menus for the selected application. By default, on the Today screen, the left Soft Key (Cal-  
endar) can also be accessed by pressing F1 and the right Soft Key (Contacts) can be accessed by pressing F2. The  
assignments for the Soft Keys can be edited using Buttons (page 5-24).  
Installed Programs  
Additional information on installed programs is listed below.  
Internet Explorer Mobile  
This browser is a subset of and is compatible with IE 7.0 (as might be installed on a desktop PC). Internet Explorer Mobile  
8 has two viewing modes: Reading mode and Overview mode.  
For information on general configuration options, see the Windows Mobile help system on the MX7 Tecton or other com-  
mercially available Internet Explorer configuration resources. Tap the IE Menu soft key (on the lower right) and select Tools  
> Options to set up the default home page, view browsing history, setup privacy and security, preferred language, and  
Other options.  
If an Internet Explorer webpage is larger than the MX7 Tecton screen can display at one time, use touch screen gestures  
for horizontal and vertical scrolling.  
For information on the version of Internet Explorer loaded on the MX7 Tecton, tap the Favorites soft key and select About  
Internet Explorer.  
Office Mobile Applications  
Office 2003 and Office 2007 formats are supported, though these are subset applications so not all objects may appear as  
expected.  
ActiveSync handles all file format conversions for Office Mobile files transferred between the MX7 Tecton and the host PC.  
ActiveSync  
ActiveSync can be setup to synchronize with an Exchange server. Contact your system administrator for configuration infor-  
mation.  
5 - 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
AppLock (Option)  
The AppLock program is accessed by the user or the AppLock Administrator at bootup or upon completion of a cold boot.  
Set parameters using the Administration option in the Settings Panel.  
Summit  
SCU (Summit Client Utility)  
Summit automatically installs and runs after every cold boot. See Wireless Network Configuration (page 11-1) for Sum-  
mit Client Utility setup information and instruction.  
Certs  
Contents of README.TXT file located in Start > Summit > Certs menu option. See Wireless Network Configuration  
for instruction on acquiring CA and user certificate files.  
Windows Media  
Codecs are included for WMA, WMV, MP3 and WAV files.  
Bluetooth (Option)  
Only installed on a Bluetooth equipped MX7 Tecton. The System Administrator can Discover and Pair targeted Bluetooth  
devices for each MX7 Tecton. The System Administrator can enable / disable Bluetooth settings and assign a Computer  
Friendly Name for each MX7 Tecton. Bluetooth can be accessed using the Bluetooth control panel, or by tapping the Blue-  
tooth icon on the Today screen.  
RFTerm (Option)  
The application can be accessed by tapping Start > RFTerm.  
Refer to the RFTerm Reference Guide for complete information and instruction. WAV files added by the user should be  
stored in System\LXE\RFTerm\Sounds.  
Status Popup  
The Status Popup provides real time information on several status icons when a specified keypress occurs.  
To use the Status Popup, first map a key to the Status window. Use the Buttons panel (Start > Settings > Personal > But-  
tons) to assign a key to Admin Statpop (for the Admin Popup) and StatPopup (for the User Popup). Use a Diamond key for  
the popup. If a Function key is used, that Function key is not available to other applications such as RFTerm.  
Use the MX7 Tecton Options control panel to configure other parameters including:  
Dismiss Status Popup on 5 second timeout.  
Information to include in Admin or User Status Popup.  
The Status Popup can be dismissed by the expiration of the timeout (if enabled), tapping the status window or pressing the  
key assigned to close the popup.  
For more information, refer to the Buttons (page 5-24) and MX7 Tecton Options (page 5-40)settings.  
HSM Connect (or LXEConnect)  
HSMConnect allows a user with an ActiveSync connection between a PC and the MX7 Tecton to display the MX7 Tecton  
screen on the host PC. Any keystrokes on the host PC are passed to the MX7 Tecton as if they were keystrokes on the MX7  
Tecton keypad.  
HSM Connect for the MX7 Tecton running Windows Mobile is available for download to the MX7 Tecton from the Getting  
Started Disc. Contact Technical Assistance (page 16-1) if the Getting Started Disc shipped with the MX7 Tecton is not  
available.  
GrabTime  
GrabTime is a utility to synchronize the MX7 Tecton with a world-wide time server. GrabTime can be started as a service by  
setting it in the Launch option. See Enhanced Launch Utility (page 9-1) for information.  
5 - 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
Synchronize with a local time server  
Use ActiveSync to copy GrabTime.ini from the My Device > Windows folder on the MX7 Tecton to the host PC.  
Edit GrabTime.ini (on the host PC) to add the local time server’s domain name to the beginning of the list of servers.  
You can then optionally delete the remainder of the list.  
Copy the modified GrabTime.ini to the My Device > Windows folder on the MX7 Tecton.  
Enhanced Launch  
Launch is a utility that runs automatically at startup. A partial list of Enhanced Launch functions includes:  
Launch a .CAB file  
Run an .EXE or .BAT file  
Process a .REG file  
Manipulate files and directories  
Modify registry keys  
Perform conditional operations  
Note: The Enhanced Launch utility does not interact with or affect the AppLock Launch command.  
For a complete list of Launch functions including commands and command structure, see Enhanced Launch Utility (page 9-  
5 - 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
MX7 Tecton OS Upgrade  
Depending on the size of the operating system, the total time required for a successful upgrade may require several minutes.  
The OS upgrade files are unique to your MX7 Tecton physical configuration and date of manufacture. OS upgrade files designed  
for one device configuration should not be used on a different device configuration.  
The MX7 Tecton running Windows Mobile must be returned to the manufacturer, Honeywell, if the device is to be re-imaged with  
any other Windows operating system (for example, Windows CE 6).  
During the upgrade process all settings revert to factory defaults. Parameters will need to be changed from factory defaults to  
your preferred values at the conclusion of the upgrade process.  
Preparation  
Contact Technical Assistance (page 16-1) to get the OS upgrade files from Honeywell.  
Removing and installing the SD Flash card should be performed on a clean, well-lit surface.  
Always perform MX7 Tecton updates when it has a fully charged main battery and/or a dependable external power source  
connected to the MX7 Tecton.  
Procedure  
1. Place the new image files and MX7Update on a SD card.  
2. Place the MX7 Tecton in Suspend Mode and remove the main battery.  
Update Icon  
SD Card Location  
3. Lift the rubber barrier and slide the SD card out of the slot. Do not remove the rubber barrier. The MX7 Tecton may not  
have a SD card in the slot because the OS is in flash.  
4. Place the card with the new image files on it into the SD slot. The label on the SD card should be facing up.  
5. Launch MX7UPDATE.EXE in My Device > Storage Card.  
6. Verify the Target OS = WinMobile check box is checked  
7. Important: If a failure occurs during the update, DO NOT RESTART (or coldboot). Follow the instructions on the  
screen to Exit the update utility then restart the update utility.  
8. Tap Start to start the update. The check box is dimmed when the Update is processing. Do not touch the device until  
the install/update is complete.  
5 - 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
When the bootloader process is complete, tap the Yes button to reboot to complete the update process. Tap the No button  
and the update is not complete.  
When the process is finished (MX7 Tecton has restarted), remove the SD card, replace the rubber barrier and replace the  
main battery. Turn the MX7 Tecton on.  
Check the OS update version by viewing the About Info (or About LXE) Settings panel.  
Note: If the application displays “Update OS Image Failed” or “Update Boot Loader Image Failed”, do not Restart the system  
manually. Perform a warm boot, then try the upgrade again. Restarting will cause a system crash, since there is no  
valid image in the MX7 Tecton system.  
Battery State and OS Upgrade  
A fully charged main battery should be installed in the MX7 Tecton prior to upgrading the operating system. A prompt may  
appear when the battery reaches Critical Low that informs the user there is not enough power in the main battery to per-  
form the upgrade.  
The operating system will not be able to execute the OS upgrade when the battery level is too low (25% or less), as there is  
a high risk that the power remaining in the battery expires when executing the upgrade and the MX7 Tecton will be left in an  
inoperable state.  
When main battery power level is too low, connect external power to the MX7 Tecton before performing the upgrade proce-  
dure. Do not disconnect external power before the upgrade process is complete.  
The MX7 Tecton running Windows Mobile must be returned to Honeywell if the device is to be imaged with any other Win-  
dows operating system (for example, Windows CE).  
Update Help  
Issue:  
The powered device won't boot up after the upgrade is finished.  
Solution:  
Send the MX7 Tecton to Product Service and Repair (page 16-1) for re-imaging. Warning: Opening the device e.g.,  
removing endcaps or access panels, etc., could void the user's authority to operate this equipment.  
Start Menu Options  
The following options represent the factory default program installation. Your system may be different based on the software and  
hardware options purchased.  
5 - 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Use the up and down arrow keys on the MX7 Tecton to quickly scroll through the icons,  
or,  
using screen touch gestures, brush the window up or down with a finger or the stylus.  
ActiveSync. Basic ActiveSync configuration, including synchronization with an Exchange server. See Using  
Avalanche. Enabler Installation and Configuration (page 10-1) installation files are loaded, but not installed at initial  
startup, on the mobile device when it is shipped.  
Calendar (page 5-55). Can be synchronized with PC Outlook calendar using ActiveSync.  
Contacts (page 5-55). Address book application. Can be synchronized with PC Outlook address book using Ac-  
tiveSync.  
Email (page 5-56). Can be synchronized with PC Outlook email using ActiveSync or it can synchronize with an Ex-  
change server.  
File Explorer (page 5-56). Displays a structured picture of files on the system.  
Help (page 5-57). Access Windows Mobile help system on the MX7 Tecton. Options to search using Windows Live  
Search are available.  
Windows Live (page 5-59). Instant Messaging service. Internet access required.  
Notes (page 5-58). Notebook application. Select Menu > View Recording Toolbar to create an audio note. Can be  
synchronized with PC Outlook notes using ActiveSync.  
Office Mobile (page 5-11). Access to Excel, PowerPoint, Word and OneNote. Compatible with Microsoft Office 2007.  
Pictures and Video (page 5-58). Picture/video viewer application. Can be synchronized with PC My Documents folder  
using ActiveSync.  
5 - 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Remote Desktop (Auto). A shortcut to Remote Desktop Mobile with Connect activated..  
Remote Desktop (page 5-67). Display remote desktop. Setup for computer, user name, password and domain re-  
quired. Use Options to setup connected options for the remote desktop.  
Task Manager (page 5-49). View and cancel running tasks.  
Tasks (page 5-59). Task list application. Can be synchronized with PC Outlook task list using ActiveSync.  
Text. Requires an email application. Can be synchronized with PC Outlook email using ActiveSync or it can synchro-  
nize with an Exchange server.  
Today (page 5-22). Configure the appearance and the items to display on the Today screen.  
Windows Live (page 5-59). Sign in to Microsoft Windows Live online service. Internet access required.  
Windows Media (page 5-60). Audio visual management program. Not supported on the MX7 Tecton.  
5 - 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Office Mobile  
Excel Mobile (page 5-64). Spreadsheets can be edited, data can be sorted, formatting and changes are pre-  
served.  
PowerPoint Mobile (page 5-65). Open, view and edit slides in landscape or portrait format. Zoom and GoTo fea-  
tures enabled.  
Word Mobile (page 5-65). Open, view, edit documents. Formats are saved. Spelling checker, cut and paste are  
available, undo and redo commands.  
Settings  
Clock & Alarms (page 5-14). Set Date, Time, Time Zone, and alarms.  
Lock (page 5-16). Set password protection.  
Power (page 5-18). Review battery status. Set time limit before device is turned off.  
Sounds & Notifications (page 5-20) Enable / disable sounds and vibrations. Set volume parameters and assign  
sound (wav) files to OS events.  
Today (page 5-22). Configure the Today screen.  
Connections Panels (page 5-50). Set up various connections between a host and the MX7 Tecton.  
Personal Panels (page 5-23). Configure Buttons, Input method and Owner information.  
System Panels (page 5-29). Review system information. Set up operating system and equipment parameters.  
5 - 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Personal  
About Info (or About LXE) (page 5-23). View software, hardware, versions and network IP. No user  
intervention required.  
Buttons (page 5-24). Set functions of programmable buttons.  
Input (page 5-26). Set input options for keypad, touch screen and voice.  
Owner Information (page 5-28). Set the mobile device owner details (name, phone, etc.). Enter notes.  
System  
About (page 5-29). Display OS version information. Set device name.  
AppLock (Application Locking) (page 6-1). AppLock Administration utility.  
Backlight (page 5-31). Set the display backlight brightness and display/keypad backlight timeout. Configure the  
timeout based on type of power source: battery or external power.  
Battery (page 5-33). View voltage and status of the main battery.  
Bluetooth Configuration (page 7-1). Set the parameters for Bluetooth device connections. .  
Certificates (page 5-34). Manage digital certificates used for secure communication.  
Data Collection Wedge (page 8-1) utility for data collected from bar code scans. Set data collection device, no-  
tifications, data stripping, prefix/suffix, and vibration (if installed) options. Assign baud rate, parity, stop bits and  
data bits for COM1 port. Assign collected data manipulation parameters.  
Encryption (page 5-35). Enable file encryption on removable storage cards.  
External GPS (page 5-36). Configure serial GPS access.  
5 - 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
License Manager (page 5-37). View license information for installed licensed applications.  
Managed Programs (page 5-37). View install history for .NET programs.  
Memory (page 5-38). Display current state of virtual memory.  
Mixer (page 5-39). Adjust the input and output parameters – volume, side-tone, and record gain, for headphone,  
software and microphone.  
MX7 Tecton Options (page 5-40). Set various device specific configuration options.  
Peripherals (page 5-42). Enable or disable touch screen heater and scanner window heater, if installed. Set the  
heater trip point in degrees C.  
Regional Settings (page 5-43). Set appearance of numbers, currency, time and date based on country region  
and language settings.  
Registry (page 5-45). Load User Defaults, Save User Defaults, Load Factory Defaults, and Warmboot.  
Remove Programs (page 5-46). Remove user installed programs.  
Screen (page 5-46). Calibrate touch screen, adjust text options.  
Task Manager (page 5-49). Display running tasks. Cancel running tasks.  
Wi-Fi (page 5-49). Set the parameters for a Summit client.  
5 - 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connections  
Beam (page 5-50). Enable receiving InfraRed and Bluetooth beams. (Not supported on the MX7 Tecton.)  
Connections (page 5-51). Configure connections to servers.  
Domain Enroll (page 5-52). Enroll in Active Directory domain.  
Network Cards (page 5-53). Set the parameters for a wireless network using the utility included in Windows Mo-  
bile.  
USB to PC (page 5-54). Set up an ActiveSync connection between a host PC and the MX7 Tecton.  
Settings Panels  
Clock & Alarms  
Time  
Adjust the settings and tap ok to save the changes. Select Yes on the popup box and the changes take effect immedi-  
ately. The Time can be set for both a Home and a Visiting location.  
5 - 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Alarms  
To set an alarm:  
1. Tap the check box to enable the alarm.  
2. Tap < Description > and enter a description. The description is limited to 63 characters.  
3. Tap the day (or days) to play the alarm.  
4. Tap the time to set the time to play the alarm. Set the time and tap ok to return to the Alarms panel.  
5. Tap the Bell icon to set the notification. Notifications may include sound, light flash (the Alpha LED flashes) and  
vibration. Set the desired options and tap ok to return to the Alarms panel.  
6. Tap ok when finished to dismiss the Alarms panel.  
More  
5 - 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Lock  
Password  
Set the lock / unlock behavior for the MX7 Tecton.  
Setting  
Default  
Prompt if device unused for  
Timer  
Unchecked  
0 minutes  
Simple PIN  
<blank>  
Password type  
Password  
Confirm  
<blank>  
Password hint  
<blank>  
Prompt if phone unused for  
Tap the check box and set the inactivity timeout before the MX7 Tecton locks.  
Password type  
When selecting a Password type the MX7 Tecton displays a numeric keypad or the input panel depending on the  
type of password selected.  
Select the Password type, Simple PIN (numeric) or strong alphanumeric. Enter the desired password and confirm.  
Note that Windows Mobile places restrictions on what it considers a valid password. If the chosen password is not  
strong enough, a warning is displayed and a new password should be entered and confirmed.  
Note: After a password has been entered, the password must be used to access the Lock panels again.  
5 - 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Hint  
If the password entry isn’t successful after a predefined number of attempts, the password hint is displayed.  
5 - 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Power  
Reports the current battery state and allows the user to set suspend timeouts.  
Setting  
Default  
On battery power:  
Turn off device if not used for  
Timer setting  
Enabled  
5 minutes  
On external power:  
Turn off device if not used for  
Timer setting  
Enabled  
5 minutes  
Battery  
Battery power is displayed for both the main and internal Super-cap batteries (backup battery).  
5 - 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Advanced  
Select the inactivity timeout period before the MX7 Tecton goes into Suspend mode. The settings on this panel are for  
the suspend timers only.  
Backlight timers are set using the Backlight (page 5-31) settings panel.  
5 - 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Sounds & Notifications  
Set volume parameters and assign sound WAV files to Windows Mobile events. Options that cannot be edited by the user  
are dimmed.  
Sounds  
Setting  
Default  
Enabled  
Enabled  
Enabled  
Disabled  
Disabled  
Events  
Programs  
Notifications  
Screen taps  
Hardware buttons  
Follow the instructions on the screen and tap OK to save the changes. Changes take effect immediately.  
5 - 20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Notifications  
The Event box lists several events that can have an associated notification. The notification, depending on the event  
selected, may consist of playing a sound, displaying a screen message, flashing a light or triggering the vibration  
motor.  
When the flash light option is selected, the MX7 Tecton flashes the Alpha LED.  
When finished, tap OK to save the changes.  
5 - 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Today  
Configure the appearance and the items to display on the Today screen.  
Appearance  
Use the Appearance panel to assign a theme for the device. The default theme is Windows Mobile Classic Blue. Any  
user installed themes are included in the list.  
Items  
Use the Items panel to select the items to be shown on the Start panel. Calendar must be selected as well as Date if  
the date is the only item to be shown on the Start menu.  
The Today timeout timer refers to the “return to Today screen” function. When the device is placed in Suspend, and  
the timer expires, a return from Suspend displays the Today screen, not the application in focus when the MX7 Tecton  
was placed in Suspend. The application in focus, which is running in the background, will need to be selected again.  
Use Options to set display parameters for highlighted items in the Checked Items list.  
5 - 22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Personal Panels  
About Info (or About LXE)  
The data cannot be edited by the MX7 Tecton user on these panels.  
Tab  
Contents  
Software  
GUID, Windows CE Version, OAL Version, Bootloader Version, Compile Ver-  
sion, Programmable Component Version(s) and Language. Language indicates  
localized version.  
Hardware  
Versions  
CPU Type, Codec Type, Display, Flash memory, and DRAM memory  
Revision level of software modules and .NET Compact Framework Version.  
Utilities, Drivers, Image, CE API, and Internet Explorer.  
Network IP  
Current IP address, MAC address, and gateway address for all network ports  
(802.11 radio, ActiveSync).  
Software  
The Software tab may display the current language. All languages are built into the OS image; English, French, Ger-  
man, Simplified Chinese, Traditional Chinese, Japanese, Korean, Spanish, Thai. .  
Hardware  
The Hardware tab displays hardware information such as CPU, keyboard type, display and memory.  
Version  
The Versions tab displays the versions of many of the software programs installed. Not all installed software installed  
on the MX7 Tecton is included in this list and the list varies depending on the applications loaded on the MX7 Tecton.  
The Image line displays the revision of the system software installed. Refer to the last three digits to determine the revi-  
sion level.  
Version window information is retrieved from the registry.  
Modify the Registry using the Registry Editor. Use caution when editing the Registry and make a backup copy of the  
registry before changes are made.  
The registry settings for the Version tab are under HKEY_LOCAL_MACHINE \ Software \ LXE \ Version in the registry.  
To add a user application to the Version panel, create a new string value under the HKLM\Software\LXE\Version key.  
The string name should be the Application name to appear in the Version window. The data for the value should be the  
version number to appear in the Version window .  
Version strings can be equal to or less than 254 characters. Because the strings are displayed in a text box, any num-  
ber can be accommodated, up to the 64K byte text box limitation.  
Network  
The Network IP tab displays the MAC address of the network adapter(s) plus IP address and gateway for connected  
adapters.  
5 - 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Buttons  
Program Buttons  
Program buttons can be used to assign functions to certain keys such as F1 through F5 and the diamond keys. Buttons  
can only be assigned to programs that have an icon in the Start menu or the Settings folder (including sub-folders). A  
program that is not in the above mentioned locations does not show up in the list here.  
Note: The button links to the shortcut to the program, not the executable file.  
Note: The System Administrator uses the Buttons setting panels to assign a Status User key and a Status Admin key  
on the Status Popup panel, see Status Popup (page 5-41).  
Setting  
Default  
32-Key Keypad  
F1  
Left Softkey  
Right Softkey  
<None>  
F2  
F3, F4, F5, D1, D2, D3  
55-Key Keypad  
F1  
Left Softkey  
Right Softkey  
<None>  
F2  
F3, F4, F5, D1  
To assign a button:  
1. Tap to highlight the desired button.  
2. Select the program or shortcut from the Assign a  
program drop down box.  
3. Tap ok.  
5 - 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Up/Down Control  
Customize the delay before repeating and the repeat rate for the up/down controls.  
5 - 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Input  
Setting  
Default  
Keyboard  
Enabled  
Input Method  
Small keys  
Word Completion  
Suggest words when entering text  
Suggest after entering  
Suggest number word(s)  
Add a space after word  
Enable auto correct  
Enabled  
A space  
4
Enabled  
Enabled  
Options  
Voice recording format  
Default zoom level for writing  
Default zoom level for typing  
Capitalize first letter of sentence  
Scroll upon reaching the last line  
8000 Hz, 8 Bit, Mono  
200%  
100%  
Enabled  
Enabled  
Input Method  
Select the preferred method of input.  
The default method of input is the keyboard or input panel. When the cursor is located in a field allowing text input, the  
input panel may automatically be displayed. If not automatically displayed, the input panel can be accessed by tapping  
on the keyboard icon at the bottom center of the screen.  
If a different input method is active, the icon for that input method is displayed instead of the keyboard icon.  
Tap ok to save any changes.  
5 - 26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Word Completion  
Options  
5 - 27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Owner Information  
Set the MX7 Tecton owner details.  
Identification  
Name, Company, Address, Telephone, E-mail  
Blank  
Blank  
Notes  
Notes  
Enter the information and tap ok to save the changes. The changes take effect immediately.  
Note: Owner Identification name listed in Start > Settings > Personal > Owner > Information is not used during Bluetooth  
operation.  
5 - 28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
System Panels  
About  
The About panels show OS versions, allow device name and description input and display copyright information.  
Version  
This screen displays information on the installed operating system and the hardware. Note that Windows Mobile is  
based on a Windows CE engine. The underlying version of Windows CE is displayed here.  
Device ID  
The device name and description can be changed by the user. Enter the name and description using either the keypad  
or the Input Panel and tap ok to save the changes. The changes take effect immediately.  
Note: The Device name listed in Start > Settings > System > About > Device ID is not used during Bluetooth  
operation.  
5 - 29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Copyrights  
This screen is presented for information only. The Copyrights information cannot be changed by the user.  
5 - 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Backlight  
Set the power management timers for the display and keypad backlights. Set the display brightness for battery and external  
power.  
Setting  
Default  
Brightness  
60%  
Battery Power  
Turn off backlight if device not used for  
30 seconds  
Turn on backlight when a button is pressed or the screen is tapped Enabled  
External Power  
Turn off backlight if device not used for  
1 minute  
Turn on backlight when a button is pressed or the screen is tapped Enabled  
Brightness  
Slide the marker left and right to select the desired keypad and display brightness level. Adjust the settings and tap OK  
to save the changes. The changes take effect immediately  
When the backlight timer expires, the display backlight and the display are Off, as is the keypad backlight. This is the  
System Idle state, there is no separate User Idle state.  
5 - 31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Battery Power  
When the MX7 Tecton is on battery power and the backlight timer expires, the display and the backlights for the display  
and keypad are turned off. Adjust the settings and tap OK to save the changes. The changes take effect immediately.  
External Power  
When the MX7 Tecton is on external power and the backlight timer expires, the display and the backlights for the dis-  
play and keypad are turned off. Adjust the settings and tap OK to save the changes. The changes take effect immedi-  
ately.  
5 - 32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Battery  
This panel is used to view the status and percentage of power remaining in the MX7 Tecton main battery.  
Jacked is shown in the Status box when the Main battery is receiving external power.  
The main battery is charged/recharged when the MX7 Tecton is docked in a powered cradle or directly cabled to an exter-  
nal power source.  
The internal battery draws power from the Main battery to maintain a charge. The Super-cap battery voltage and percent-  
age of power fluctuate continuously.  
When there is no Main battery in the unit, the internal battery begins to discharge as it maintains RAM and other vital set-  
tings. After a Main battery is installed, the internal battery begins to draw power from the Main battery again and is fully  
recharged in five minutes or less.  
Note: Frequent connection to an external power source, if feasible, is recommended to maintain main battery charge status  
as the Super-cap battery cannot be recharged by a dead or missing main battery.  
5 - 33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Certificates  
Manage digital certificates used for secure communication.  
View – displays details of the certificate. Personal certificates may be extended from the view screen.  
Delete – removes the certificate from the device. Delete is not available if the certificate was installed by a device adminis-  
trator.  
Certificates are divided into three types: Personal, Intermediate and Root.  
See Certificates (page 11-36) chapter for detailed instruction on generating certificates.  
Personal  
This panel lists any installed Personal certificates. Personal certifi-  
cates are used to identify the user of the device.  
To install a User certificate:  
1. Copy the .pfx or .p12 file to a folder on the MX7 Tecton.  
2. Use File Explorer to browse to the location of the file and open  
the file by tapping the file name.  
3. Type in the password to unlock the certificate and tap Done.  
4. The new certificate is copied to the Personal certificate store on  
the MX7 Tecton.  
Intermediate  
This panel lists any installed Intermediate certificates. Intermediate  
certificates are used to help authenticate certificates received from  
other hosts.  
To install an Intermediate certificate:  
1. Copy a DER-encoded .cer file, a base64-encoded .cer file or a  
.pfx file to a folder on the MX7 Tecton.  
2. Use File Explorer to browse to the location of the file and open  
the file by tapping the file name.  
3. The new certificate is copied to Intermediate certificate store on  
the MX7 Tecton.  
5 - 34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Root  
This panel lists any installed Root certificates. Root certificates are  
used to authenticate certificates received from other hosts.  
To install a Root certificate:  
1. Copy a DER-encoded .cer file, a base64-encoded .cer file or a  
.pfx file to a folder on the MX7 Tecton.  
2. Use File Explorer to browse to the location of the file and open  
the file by tapping the file name.  
3. The new certificate is copied to Root certificate store on the MX7  
Tecton.  
Encryption  
This panel enables or disables encryption of data files on removable storage cards. The default is Disabled. Tap the check  
box to encrypt files when placed on a storage card.  
5 - 35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
External GPS  
Setting  
Default  
None  
GPS Program Port  
GPS Hardware Port  
Baud Rate  
None  
4800  
Access  
Automatic  
This panel configures serial GPS access over hardware serial ports using the Microsoft GPS manager. The port used,  
baud rate and port sharing must be specified.  
In order to use the configuration items on these panels, GPS applications must use the Microsoft GPS API interface rather  
than reading the serial port directly. If the GPS application reads the serial port directly, these settings are not necessary.  
5 - 36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
License Manager  
Use this option to view software license registration details, and service contract length for purchased software installed on  
the MX7 Tecton. Note the following image is a sample screen.  
Your License Manager panel may show more tabs, e.g., RFTerm, depending on the number of software applications run-  
ning on the MX7 Tecton that require a license.  
Software and driver version information is located in About (page 5-29). Copyright information is located in the Copyrights  
tab of the About control panel.  
Managed Programs  
This panel displays the install history for .NET managed programs. The list is read only.  
5 - 37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Memory  
These panels report the current state of virtual memory.  
Main  
The split between Storage memory and Program memory is not adjustable.  
Storage Card  
The pop-up list shows all mounted storage, both fixed and removable.  
The Find prompt at the bottom of the screen launches the Search utility.  
5 - 38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Mixer  
The MX7 Tecton has a speaker located above the scan button. It is active when a headset is not connected to the device.  
Use the settings on these panels to adjust the volume, record gain and sidetone for microphone input, speaker and speaker  
output.  
Headsets can be enabled, disabled and selected using these panels.  
Setting  
Default  
Output  
Speaker Volume  
Headset Volume  
Input  
6.0 dB  
3.0 dB  
Input  
Mic1  
Record Gain  
Boost  
24.0 dB  
+ 30.0 dB  
6.0 dB / Disabled  
Sidetone  
Tap and hold the sliders and move them either left or right, or tap the left and right arrows, to adjust decibel levels.  
Tap the Test button on the Output panel to hear a changed setting.  
5 - 39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
MX7 Tecton Options  
Set MX7 Tecton specific device options. Options that cannot be edited by the user are dimmed.  
Communication  
By default, TCP/IP version 6 is enabled on the MX7 Tecton. Tap to uncheck this check box to disable TCP/IP version 6.  
By default, Remote Desktop Autologin is disabled. Tap this check box to enable Remote Desktop Autologin.  
Autolaunch TimeSync enables time synchronization when the MX7 Tecton boots.  
Misc  
There are no user configurable options on this screen.  
5 - 40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Status Popup  
When the Status popup window is enabled, and displayed, it is placed on top of the window in focus and hides any  
data beneath it.  
The Status Popup window is closed by pressing the assigned Status User or Status Admin key sequence.  
Note: Use a Diamond key for the assigned key sequence to use when opening and closing the popup. If a Function  
key is used, that Function key is not available to applications that generally use Function keys such as RFTerm.  
Using the Buttons settings panel (Start > Settings > Personal > Buttons > Program Buttons), the System Adminis-  
trator must first assign a Status User key for the end-user when they want to toggle the Status Popup Window on or off.  
Select the desired key and assign that key to StatPopup.  
Similarly the System Administrator must also assign a Status Admin key to perform the same function for the Admin  
popup. Select the desired key and assign that key to Admin StatPop.  
Status popup window display options (taskbar icons) are assigned on the Status Popup tab. E.g., WLAN radio, Battery  
meter, Bluetooth status, RFTerm SecID's (Secondary IDs), etc.  
The default is for the User and Admin status popup windows to show all status information. The 5-second timeout to  
remove the status popup from the display is disabled by default for the User and Admin status popup windows.  
5 - 41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Peripherals  
This panel is used to enable and disable the touch screen heater and scan window heater.  
Setting  
Default  
Enabled  
Touch screen heater  
Scan window heater  
Heater Trip Point  
Enabled  
0º C / 32º F  
Note: Settings have no effect if the touch screen / scan window heaters are not installed.  
Click the radio button to enable or disable the heaters.  
Choose a different trip point from the drop down list and tap OK. The change is in effect after the Peripherals panel is  
saved.  
5 - 42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Regional Settings  
Regional Settings has the same general format and function as Regional Settings on a PC.  
5 - 43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5 - 44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Registry  
Choose an MX7 Tecton software reload scheme.  
Load User Defaults  
When clicked, a standard load file dialog is opened, to allow the user to pick a Registry Save (.RSG) file. The applet  
then copies the specified User registry file to the Active registry. The user is asked to verify a reboot, and then the  
applet does a warmboot to activate the new registry.  
Load User Defaults takes 20 seconds from SD card, or 10 seconds from internal flash.  
Save User Defaults  
When clicked, a standard Save File dialog is opened, to allow the user to name the Registry Save (.RSG) file. The  
applet then copies the Active registry to the specified User registry file.  
Save User Defaults takes 30 seconds to save to SD card, or 10 seconds to save to internal flash.  
Load Factory Defaults  
The applet copies the Factory Default registry from the OS to the Active registry (by deleting the current registry). The  
user is asked to verify a reboot, and then the applet does a restart to activate the factory default registry. If a user pass-  
word has been set, the applet warns the user that the password will be erased, and asks them to enter it before the  
reboot is allowed.  
Warmboot  
When clicked, the OS does a registry flush (Active registry saved to Flash registry hive), and then a warmboot.  
Restart  
When clicked, the OS does a registry flush, and then a restart.  
5 - 45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
             
Remove Programs  
This panel is used to uninstall programs. The Remove Program listing is for all programs installed via ActiveSync or via a  
CAB file. Programs installed via a package file are not included in this list.  
Screen  
Use the options on these panels to switch screen orientation, align or calibrate the touch screen and select Clear Type.  
General  
5 - 46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Align Screen  
Tap the Align Screen button. The align screen opens and displays a large cross-hair in the middle of the screen. Tap  
the middle of the cross-hair as it moves around the screen. When the process is complete, the General screen is dis-  
played. Tap ok and the changes are saved. The new alignment is in effect immediately.  
Clear Type  
5 - 47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Text Size  
Tap the marker and slide it across the bar. As the marker moves, the example text increases or decreases. Tap ok and  
the change is saved. The new text size is in effect immediately.  
5 - 48  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Task Manager  
This panel displays all running tasks as well as the memory and CPU bandwidth being used by each task.  
Tapping on the column headings at the top of the screen sorts the tasks by the contents of that column. Tapping the same  
heading a second time reverses the sort order of that column.  
Highlight an application then tap End Task. More options are available in the Task Manager Menu.  
Highlighting then right-clicking on an application displays a popup menu with the following choices:  
Switch To – Switch to the highlighted task. Double-clicking on the task name also performs this function.  
End Task – End the selected task only.  
End All Tasks – End all tasks.  
The list is reset by cold boot (or restart).  
Note: Any Windows Mobile program that has been run, even if the program has been exited, remains in memory ready to  
run again. If memory runs out, the programs are released from memory. However, to avoid out of memory operational  
problems, it is best to manually terminate unwanted tasks using this option.  
Wi-Fi  
Use this option to set parameters and manage profiles for the wireless client pre-loaded on your MX7 Tecton.  
See Summit Client Utility (page 11-1) for more information.  
5 - 49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Connections Panels  
Beam  
Enable or disable receiving OBEX (oBject EXchange is a communications protocol used to exchange information  
between mobile devices. The devices must support infrared communication.) data beams, either by IrDA (Infrared Data  
Association, also used as an abbreviation for the Infrared [IR] port on devices.) or Bluetooth.  
Note: The MX7 Tecton does not support beaming.  
Beam Settings is disabled as the MX7 Tecton does not support beaming.  
5 - 50  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Connections  
Start > Settings > Connections > Connections  
Configure connections to a host PC.  
Advanced Options  
5 - 51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Domain Enroll  
Enroll in Active Directory.  
To begin enrollment, tap Enroll in the Status bar. Contact your system administrator for the applicable information to com-  
plete the screens.  
5 - 52  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Network Cards  
This panel displays a listing of network adapters. The list is based on drivers installed in the registry whether the adapter is  
actually supported by the hardware or not.  
The Network Cards may not always be displayed. If this icon is not displayed, access Network Cards by selecting Start >  
Settings > Connections > Wi-Fi > Network Cards tab.  
To configure a network card, tap on the adapter name and enter the IP address (or select Use server assigned IP address)  
and the name server addresses.  
5 - 53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
USB to PC  
The option is disabled by default. This option can be enabled when connection to a host PC using a USB cable is required.  
Standard Microsoft Applications  
Note: The intent of this segment is to document standard Microsoft applications loaded on the MX7 Tecton. Documentation only  
consists of a panel and minimal explanation. These are standard Microsoft small form applications for which help is  
available using Help on the MX7 Tecton and the Internet.  
Calculator  
Mathematical calculator application. Use Copy (Ctrl+C) and Paste  
(Ctrl+V) to move results between applications.  
5 - 54  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Calendar  
Calendar/date book application. Can be synchronized with PC Out-  
look calendar using ActiveSync.  
Contacts  
Address book application. Can be synchronized with PC Outlook ad-  
dress book using ActiveSync.  
5 - 55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Email  
Email application. Can be synchronized with PC Outlook email using  
ActiveSync or it can synchronize with an Exchange server.  
File Explorer  
Displays a structured picture of files on the system.  
5 - 56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Getting Started  
This application provides several wizards to walk a user through de-  
vice configuration.  
Help  
Access Windows Mobile help system on the MX7 Tecton. Options to  
search using Windows Live Search are available.  
5 - 57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Notes  
Notes. Notebook application. Select Menu > View Recording Tool-  
bar to create an audio note. Can be synchronized with PC Outlook  
notes using ActiveSync.  
Pictures and Video  
Pictures and Video. Picture/video viewer application. Can be syn-  
chronized with PC My Documents folder using ActiveSync.  
5 - 58  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Tasks  
Tasks. Task list application. Can be synchronized with PC Outlook  
task list using ActiveSync.  
Windows Live  
Windows Live. Sign in to Microsoft Windows Live online service. In-  
ternet access required.  
5 - 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Windows Media  
Windows Media. Audio visual management program. Not supported  
on the MX7 Tecton.  
5 - 60  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Internet Explorer Mobile  
Set options for Internet connectivity. The navigation icons change state based on the web page contents.  
Navigation Icon  
Action  
Navigation Icon  
Action  
Add folder  
Favorites  
Add to Favorites  
Go Back  
Options  
Soft Input Panel  
Zoom In  
Zoom Out  
Delete Favorite  
Edit Favorites  
5 - 61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Options  
5 - 62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5 - 63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Office Mobile  
A suite of business related applications. Files can be created, opened, viewed, saved in different formats, etc.  
Note: For Microsoft Office Mobile instruction for Word, PowerPoint, Excel and OneNote, refer to commercially available  
Microsoft Office Mobile user guides.  
Excel Mobile  
Spreadsheets can be edited, data can be sorted, formatting and changes are preserved. Select Menu > Options to  
change default settings.  
5 - 64  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
PowerPoint Mobile  
Open, view and edit slides in landscape or portrait format. Zoom and GoTo features enabled. Select Menu > Options  
to change default settings.  
Word Mobile  
Open, view, edit documents. Formats are saved. Spelling checker, cut and paste are available, undo and redo com-  
mands. Select Menu > Options to change default settings.  
5 - 65  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
OneNote Mobile  
OneNote is an electronic version of a paper notebook. Select Menu to change default settings.  
5 - 66  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Remote Desktop  
Start > Remote Desktop Mobile  
Using Remote Desktop Mobile, you can log on to a remote computer running Terminal Services or Remote Desktop and use all  
the programs available on that computer from your mobile device. For example, instead of running Word Mobile on the MX7  
Tecton, you can run the desktop computer version of Word and access all of the .doc files on that computer from your device.  
Set Remote Desktop Mobile Options  
Before connecting to a remote computer, set Remote Desktop Mobile options to improve display and resource when con-  
nected, if desired. Tap Options in the taskbar. Tap OK when finished.  
5 - 67  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Connect to a Remote Server  
1. Configure the radio.  
2. Enter the name of the computer to which you want to connect. If needed, enter the port number at the end of the  
computer name (remotecomputername:portnumber).  
3. Enter the user name, password and domain.  
4. Tap the Save password check box if it is blank.  
5. Tap Connect to complete the connection and save the password.  
6. Select Disconnect from Remote Desktop connection.  
7. Create a folder titled Startup under the System folder.  
8. Copy Remote.exe from the Windows folder to the \System\Startup folder just created.  
9. Select Start > Settings > System > MX7 Tecton Options and check Remote Desktop Autologon.  
10. Select OK and yes to reboot.  
11. Result: The unit will boot into the Remote Desktop Connection.  
5 - 68  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing Applications  
Applications can be installed on the MX7 Tecton from CAB files or package files.  
Package files have some unique characteristics:  
Package files patch the operating system so they become non-volatile. Even a Clean Boot does not remove the programs.  
CAB files are (re)installed after a cold boot, but not after a suspend/resume since the OS was not reset and the CAB files are  
still in use.  
Packages can contain registry settings which are installed at setup, similar to a CAB file.  
Package files cannot be uninstalled, reinstalled or reverted to an earlier version.  
Packages can be digitally signed.  
A super package file can be created containing multiple package files. Because the MX7 Tecton must reboot after every  
package installation, a super package may make the installation faster.  
Package files have a .PKG extension, super package files have a .PKS extension.  
An unsigned executable (CAB or package file) prompts the user when executed:  
The program is from an unknown publisher. Running it can possibly harm your device. Do you want to continue?  
If you trust the program, tap Yes. Otherwise tap No.  
Preparation  
Package files can be copied to the MX7 Tecton via ActiveSync or they can be installed from the Flash card.  
Package File Installation  
The MX7 Tecton must be connected to external AC power. IMPORTANT – Because the package file installation actually  
rewrites portions of the operating system, it is important that power is not interrupted during package file installation. If  
power is interrupted, the operating system may be damaged, requiring the MX7 Tecton to be returned to Honeywell for  
repair.  
Use File Explorer to browse to the location of the package file.  
1. Tap the package file. Note that by default the file extension is hidden. The package file can be either a single package  
file or a super package file.  
2. The installation process begins.  
3. A Validating Update display is presented indicating that an update has been received. The device will verify the update  
before installing.  
4. When prompted, tap Install Now to begin the installation.  
5. The MX7 Tecton reboots and displays an Update message while the package is being installed.  
6. When the installation is completed, the MX7 Tecton reboots again and displays the summary screen.  
Refer to Help below if there is a problem with the package installation.  
PKG Installation Help  
Issue:  
The MX7 Tecton isn’t connected to AC power.  
Solution:  
Updates cannot be installed while the device is on battery power. To continue, connect the power adapter to the mobile  
device. The update will be deleted when Cancel is tapped.  
Tap Cancel. Connect the MX7 Tecton to AC power and try the update again.  
The message that the update will be deleted only means that the scheduled update was deleted. The package file IS  
NOT deleted and remains on the storage card.  
5 - 69  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Issue:  
The package is already installed or is an older version than installed.  
Solution:  
Status unsuccessful. The update could not be installed because the update has already been installed or the package  
file is an earlier version than the version currently installed on the MX7 Tecton.  
Tap Done to exit the update process.  
The message that the update could not be installed and is deleted only means that the scheduled update was deleted.  
The package file IS NOT deleted and remains on the storage card.  
Contact Technical Assistance (page 16-1) or your system administrator for more information on package versions.  
Using ActiveSync  
Introduction  
Requirement : ActiveSync (version 4.5 or higher for Windows XP host computers) must be resident on the host (desktop/  
laptop) computer. Windows Mobile Device Center (version 6.1 or higher) is required for a Windows Vista or higher desktop/  
laptop computer. ActiveSync and Windows Mobile Device Center for the host computer is available from the Microsoft web-  
site. Follow their instructions to locate, download and install ActiveSync or Windows Mobile Device Center on your desktop  
computer.  
Note: For readability in this section, ActiveSync will be used in instructions and explanations. If you have a Windows Vista  
or higher operating system on your host computer, replace “ActiveSync” with “Windows Mobile Device Center”.  
Using Microsoft ActiveSync, you can synchronize information on your host computer with the MX7 Tecton and vice versa.  
Synchronization compares the data on your mobile device with your host computer and updates both with the most recent  
data.  
For example, you can:  
Back up and restore your device data.  
Copy (rather than synchronize) files between your device and host computer.  
Control when synchronization occurs by selecting a synchronization mode. For example, you can synchronize continually  
while connected to your host computer or only when you choose the synchronize command.  
By default, ActiveSync does not automatically synchronize all types of information. Use ActiveSync Options to specify the  
types of information you want to synchronize. The synchronization process makes the data (in the information types you  
select) identical on both your host computer and your device.  
When installation of ActiveSync is complete on your host computer, the ActiveSync Setup Wizard begins and starts the fol-  
lowing processes:  
connect your MX7 Tecton to your host computer,  
set up a partnership so you can synchronize information between your mobile device and your desktop computer, and  
customize your synchronization settings.  
Because ActiveSync is already installed on the MX7 Tecton, your first synchronization process begins automatically when  
you finish setting up your host computer in the ActiveSync wizard. For more information about using ActiveSync on your  
host computer, open ActiveSync, then open ActiveSync Help.  
5 - 70  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Initial Setup  
The initial setup of ActiveSync must be made via a USB connection. Partnerships can only be created using USB cable  
connection.  
Connect via USB  
The default connection type is USB Client. This is the only connection option supported on the MX7 Tecton.  
To verify it is set to USB, select  
Start > Settings > Connections > USB to PC  
Ensure the check box for “Enable advanced network functionality” is checked. Tap OK to return to the Connections panel.  
Connect the USB cable to the PC (the host) and the MX7 Tecton (the client) as detailed below. ActiveSync will start auto-  
matically when the USB cable is connected.  
When the MX7 Tecton loses connection, e.g., enters Suspend Mode, etc., the connection to ActiveSync will be lost. When  
the MX7 Tecton resumes, the ActiveSync session will automatically re-connect.  
Cable for USB ActiveSync Connection  
MX7052CABLE - MX7 Tecton Charge/Comm Interface Cable with USB Client port for ActiveSync. USB end of cable  
connects to PC/Laptop USB port.  
Connect the MX7 Tecton end of the cable to the I/O port on the bottom of the MX7 Tecton  
The USB type A connector on the cable connects to a USB port on a PC or laptop.  
It is not necessary to connect the power connector on the cable in order to use ActiveSync.  
Insert A/C  
Adapter Cable  
Connect to Input/  
Output Port  
Connect to USB  
client port  
Explore  
From the ActiveSync Dialog on the Desktop PC, tap the Explore button, which allows you to explore the mobile device from  
the PC side, with some limitations. You can copy files to or from the mobile device by drag-and-drop. You will not be allowed  
to delete files or copy files out of the \Windows folder on the mobile device. (Technically, the only files you cannot delete or  
copy are ones marked as system files in the original build of the Windows image. This, however, includes most of the files  
in the \Windows folder).  
Backup Data Files using ActiveSync  
Use the following information to backup data files from the mobile device to a PC using the appropriate cable and  
ActiveSync.  
Requirements  
A partnership between the mobile device and ActiveSync has been established.  
A desktop or laptop PC with an available USB port and a mobile device with a USB port. The desktop or laptop PC  
must be running Windows XP or greater.  
Use the specific USB cable as shown above in Connect via USB.  
Connect  
Connect the USB cable to the PC (the host) and the mobile device (the client).  
The “Get Connected” wizard on the host PC checks COM ports to establish a connection for the first time.  
Note: USB synchronization will start automatically when the cable is connected.  
Disconnect  
Disconnect the cable from the MX7 Tecton.  
Open the status bar icon in the lower right hand corner of the status bar. Then tap the Disconnect button.  
5 - 71  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
When the MX7 Tecton loses connection, e.g., enters Suspend Mode, etc., the connection to ActiveSync will be lost.  
When the MX7 Tecton resumes, the ActiveSync session will automatically re-connect.  
MX7 Tecton with a Disabled Touch Screen  
A MX7 Tecton touch screen can be disabled (using the MX7 Tecton Options control panel Misc tab). In these cases, it may  
be easier to configure the MX7 Tecton using ActiveSync and HXM Connect (or LXEConnect) rather than using the MX7  
Tecton keypad only.  
Reset and Loss of Host Re-connection  
ActiveSync assigns a partnership between a client and a host computer. A partnership is defined by two objects – a unique  
computer name and a random number generated when the partnership is first created. An ActiveSync partnership between  
a unique client can be established to two hosts.  
When the mobile device is reset (return to default settings), the random number is deleted – and the partnership with the  
last one of the two hosts is also deleted. The host retains the random numbers and unique names of all devices having a  
partnership with it. Two clients cannot have a partnership with the same host if they have the same Device Name.  
If the reset mobile device tries to reestablish the partnership with the same host PC, a new random number is generated for  
the mobile device and ActiveSync will insist the unique name of the mobile device be changed. If the mobile device is asso-  
ciated with a second host, changing the name will destroy that partnership as well. This can cause some confusion when  
re-establishing partnerships with hosts.  
ActiveSync Help  
Issue:  
ActiveSync on the host says that a device is trying to connect, but it cannot identify it  
Solution:  
One or more control lines are not connected. This is usually a cable problem, but on a laptop or other device, it may  
indicate a bad serial port.  
If the MX7 Tecton is connected to a PC by a cable, disconnect the cable from the MX7 Tecton and reconnect it again.  
Check that the correct connection is selected.  
See Also: Reset and Loss of Host Re-connection above.  
Issue:  
ActiveSync indicator on the host (disc in the toolbar tray) turns green and spins as soon as you connect the cable,  
before tapping the Connect icon.  
Solution:  
One or more control lines are tied together incorrectly. This is usually a cable problem, but on a laptop or other device,  
it may indicate a bad serial port.  
Issue:  
ActiveSync indicator on the host turns green and spins, but connection never occurs  
Solution:  
Check that the correct connection is selected.  
-or-  
Incorrect or broken data lines in cable.  
5 - 72  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Issue:  
ActiveSync indicator on the host remains gray  
Solution 1:  
ActiveSync icon on the PC does not turn green after connecting USB cable from MX7 Tecton.  
1. Disconnect MX7 Tecton USB cable from PC.  
2. Suspend/Resume or Restart the MX7 Tecton.  
3. In ActiveSync > File > Connection Settings on PC disable Allow USB Connections and tap OK.  
4. Re-enable Allow USB Connections on the PC and tap OK.  
5. Reconnect USB cable from MX7 Tecton to PC.  
Solution 2:  
The host doesn’t know you are trying to connect. May mean a bad cable, with no control lines connected, or an incom-  
patible baud rate. Try the connection again, with a known good cable.  
Configuring the MX7 Tecton with HSM Connect (or LXEConnect)  
HSM Connect (or LXEConnect) allows a user to view the MX7 Tecton screen remotely from a PC using an ActiveSync connec-  
tion.  
Requirements: ActiveSync (version 4.5 or higher for Windows XP host computers) must be resident on the host computer. Win-  
dows Mobile Device Center (version 6.1 or higher) is required for a Windows Vista/ or greater host computer.  
ActiveSync is already installed on the MX7 Tecton. The MX7 Tecton is pre-configured to establish a USB ActiveSync connection  
to a host PC when the USB cable is attached to the MX7 Tecton and the host PC.  
Install HSM Connect  
1. HSM Connect for the MX7 Tecton running Windows Mobile is available on the Getting Started Disc.  
2. Download the files to a location on your host PC hard drive.  
3. Execute the setup.exe file that was copied to the host PC. This setup program installs the HSM Connect utility.  
4. Follow the on screen installation prompts.  
5. When the installation is complete, create a desktop shortcut to HSM Connect.  
6. HSM Connect is now installed on the host PC and ready to use.  
Using HSM Connect  
1. Power up the MX7 Tecton.  
2. Connect the MX7 Tecton to the host PC using the USB connection cable. Once connected, the ActiveSync dialog box  
appears and the ActiveSync connection is automatically established.  
3. Select “No” for partnership when prompted. Dismiss any ActiveSync dialog boxes warning a partnership is not set up. It  
is not necessary to establish a partnership to use HSM Connect. However, if a partnership is desired for other reasons,  
one may be established now.  
4. Double-tap the HSM Connect icon that was created on the PC desktop.  
5. HSM Connect launches.  
5 - 73  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
6. Click the OK button to dismiss the About CERDisp dialog box on the MX7 Tecton desktop by clicking the OK button in  
the HSM Connect window on the PC desktop. The dialog box automatically times out and disappears after  
approximately 20 seconds.  
7. The MX7 Tecton can now be configured from the HSM Connect window. Input from the PC’s mouse and keyboard are  
recognized as if they were attached to the MX7 Tecton.  
8. When the remote session is completed, terminate the HSM Connect program by selecting File > Exit or clicking on the  
X in the upper right hand corner to close the application, then disconnect the ActiveSync cable.  
5 - 74  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
AppLock (Application Locking)  
Introduction  
AppLock is designed to be run on Windows based devices only. The AppLock program is factory installed.  
Configuration parameters are specified by the AppLock Administrator for the MX7 Tecton end user. AppLock is password pro-  
tected by the Administrator.  
End user mode locks the end user into the configured application or applications. The end user can still reboot the mobile device  
and respond to dialog boxes. The administrator-specified applications are automatically launched in the specified order and run  
in full screen mode when the MX7 Tecton boots up.  
When the mobile device is reset to factory default values, for example after a cold reset, the Administrator may need to configure  
the AppLock parameters again.  
The assumption, in this chapter, is that the first user to power up a new mobile device is the system administrator.  
MX7 Tecton AppLock is setup by the Administrator by tapping Start > Settings > System > Administration icon.  
Note: AppLock Administrator panel file Launch option does not inter-relate with similarly-named options contained in other MX7  
Tecton System Panels.  
Note: A few applications do not follow normal procedures when closing. AppLock cannot prevent this type of application from  
closing, but is notified that the application has closed. For these applications, AppLock immediately restarts the application  
(see Auto Re-Launch) which causes the screen to flicker. If this type of application is being locked, the administrator  
should close all other applications before switching to end user mode to minimize the screen flicker.  
Setup a New Device  
Prerequisites:  
A default input method (Input Panel, Transcriber, or custom input method) is assigned.  
Devices with AppLock are shipped to boot in Administration mode with no default password, thus when the device is first  
booted, the user has full access to the MX7 Tecton and no password prompt is displayed. After the administrator specifies appli-  
cations to lock, assigns passwords and the device is rebooted or the hotkey is pressed, the MX7 Tecton switches to end user  
mode.  
The process to configure a new device using AppLock is as follows:  
1. Insert a fully charged battery and press the Power button.  
2. Connect an external power source to the device (if required).  
3. Adjust screen display, audio volume and other parameters if desired. Install accessories (e.g., handstrap, stylus) if needed.  
4. Tap Start > Settings > System > Administration control panel.  
5. Assign a Switch Key (Hot Key) sequence for AppLock on the Security (page 6-9).  
6. Assign an application on the Application (page 6-5). More than one application can be assigned.  
7. Assign a password on the Security panel.  
8. Select a view level on the Status (page 6-11), if desired.  
9. Tap OK.  
10. Press the Switch Key sequence to launch AppLock and lock the configured application(s). The device is now in end user  
mode.  
Administration Mode  
Administration mode gives full access to the mobile device, hardware and software configuration options.  
The administrator must enter a valid password (when a password has already been assigned) before access to Administration  
mode and configuration options are allowed. The administrator can configure the following options:  
Create/change the keystroke sequence to activate administrator access.  
6 - 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Create/change the password for administrator access.  
Assign the name of the application, or applications, to lock.  
Select the command line of the application to lock.  
In addition to these configuration options, the administrator can view and manage the status logs of AppLock sessions.  
Administrator default values for this device are:  
Administrator Hotkey - Shift+Ctrl+A  
Password - none  
Application path and name - none  
Application command line - none  
End User Mode  
The default end user Hotkey Activation key is Ctrl+Spc.  
End user mode locks the end user into the configured application or applications. The end user can still reboot and respond to  
dialog boxes. Each application is automatically launched and runs in full screen mode when the device boots up.  
The end user cannot unintentionally or intentionally exit the application nor can the end user execute any other applications.  
Normal application exit or switching methods and all Microsoft defined Windows OS key combinations, such as close (X) icon,  
File Exit, File Close, Alt-F4, Alt-Tab, etc. are disabled. The Windows OS desktop icons, menu bars, task bar and system trays  
are not visible or accessible. Task Manager is not available.  
If the end user selects File/Exit or Close from the application menu bar, the menu is cleared and nothing else happens; the  
application remains active. Nothing happens when the end user clicks on the Close icon on the application’s title bar and the  
application remains active.  
Note: A few applications do not follow normal procedures when closing. AppLock cannot prevent this type of application from  
closing, but is notified that the application has closed. For these applications, AppLock immediately restarts the application  
which causes the screen to flicker. If this type of application is being locked, the administrator should close all other  
applications before switching to end user mode to minimize the screen flicker.  
Windows accelerator keys such as Alt-F4 are disabled.  
6 - 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Passwords  
A password must be configured. If the password is not configured, a new device switches into Administration mode without  
prompting for a password. In addition to the Administrator hotkey press, a mode switch occurs if inaccurate information has  
been configured or if mandatory information is missing in the configuration.  
There are several situations that display a password prompt after a password has been configured.  
If the configured hotkey is pressed, the password prompt is displayed. In this case the user has 30 seconds (and within three  
attempts) to enter a password. If a valid password is not entered within 30 seconds, the password prompt is dismissed and the  
device returns to end user mode.  
All other situations that present the password prompt do not dismiss the prompt -- this is because the other situations result in  
invalid end user operation.  
These conditions include:  
If inaccurate configuration information is entered by the administrator, i.e., an application is specified that does not exist.  
If the application name, which is mandatory for end user mode, is missing in the configuration.  
Invalid installation of AppLock (e.g., missing DLLs).  
Corrupted registry settings.  
To summarize, if an error occurs that prevents AppLock from switching to end user mode, the password will not timeout and  
AppLock will wait until the correct password is entered.  
AppLock Password Help  
Contact Technical Assistance (page 16-1) when troubleshooting passwords.  
End-User Switching Technique  
The default end user Hotkey Activation key is Ctrl+Spc..  
Switchpad Menu  
A check mark indicates applications currently active or available for Launching by the user. When Keyboard is selected, the MX7  
Tecton default input method (Input Panel, Transcriber, or custom input method) is activated.  
The check mark to the left of the application name indicates that the application is active.  
If the application is listed but does not have a check mark to the left of the application name, this means the application is con-  
figured in AppLock and can be manually launched by tapping on the application name in the list.  
Using a Stylus Tap  
When the mobile device enters end user mode, a Switchpad icon (it looks like three tiny windows one above the other) is  
displayed in the lower right corner of the display. The Switchpad is always visible on top of the application in focus. How-  
ever, if only one application is configured in AppLock and the Input Panel is disabled the Switchpad is not visible.  
When the user taps the Switchpad icon, a menu is displayed showing the applications available to the user. The user can  
tap an application name in the popup menu and the selected application is brought to the foreground. The previous applica-  
tion continues to run in the background. Stylus taps affect the application in focus only. When the user needs to use the  
Input Panel, they tap the Keyboard option. Input Panel taps affect the application in focus only.  
Using the Switch Key Sequence  
One switch key sequence (or hotkey) is defined by the administrator for the end user to use when switching between locked  
applications. This is known as the Activation key. The Activation key is assigned by the Administrator using the Global Key  
setting in the Application panel.  
6 - 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
When the switch key sequence is pressed on the keypad, the next application in the AppLock configuration is moved to the  
foreground (in focus) and the previous application moves to the background. The previous application continues to run in  
the background. End user key presses affect the application in focus only.  
Hotkey (Activation hotkey)  
If the MX7 Tecton has been configured to use AppLock to allow the user to switch between applications, the default user  
Activation key is Ctrl+Spc. The key sequence switches the focus between one application and another. Data entry affects  
the application running in the foreground only. Note that the system administrator may have assigned a different key  
sequence to use when switching applications.  
End User Internet Explorer (EUIE)  
AppLock supports applications that utilize Internet Explorer, such as HTML pages and JAVA applications. The end user can run  
an application by entering the application name and path in Internet Explorer’s address bar.  
To prevent the end user from executing an application using this method, the address bar and Options settings dialog are  
restricted in Internet Explorer. This is accomplished by creating an Internet Explorer that is used in end user mode: End user  
Internet Explorer (EUIE.EXE). The EUIE executes the Internet Explorer application in full screen mode which removes the  
address bar and status bar. The Options Dialog is also removed so the end user cannot re-enable the address bar.  
The administrator specifies the EUIE by tapping the Internet check box in the Application tab of the Administrator applet. The  
internet application should then be entered in the Application text box.  
When the Internet check box is enabled, the Menu and Status check boxes are available.  
Enabling the Menu check box displays the EUIE menu which contains navigation functions like Back, Forward, Home, Refresh,  
etc., functions that are familiar to most Internet Explorer users. When the Menu check box is blank, the EUIE menu is not dis-  
played and Navigation functions are unavailable.  
When the Status check box is enabled, the status bar displayed by EUIE gives feedback to the end user when they are navigat-  
ing the Internet.  
If the standard Internet Explorer that is shipped with the mobile device is desired, it should be treated like any other application.  
This means that IEXPLORER.EXE (or equivalent) should be specified in the Application text box and the internet application  
should be entered in the command line. In this case, do not check the Internet check box.  
6 - 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Application Configuration  
The default Administrator Hotkey sequence is Shift+Ctrl+A.  
Administrator mode allows access to all features on the device. When the hotkey is pressed to switch into Administrator mode, a  
password prompt is displayed (if a password has been configured). A password must be entered within 30 seconds (and within  
three tries) or the password prompt is removed and the device remains in end user mode with the focus returned to the locked  
application. Without entry of a valid password, the switch into Administrator mode will not occur.  
The password prompt is displayed if a password has been configured. When the valid password is entered, the Administration  
panel is displayed. When a valid password is not entered within 30 seconds, the user is returned to the System Panel.  
If a password has not been configured, the Administrator panel is displayed.  
Note: Before setting up multiple instances of the same application, make sure the targeted software application will allow two  
instances to run at the same time.  
Application  
Use the Application tab options to select the applications to launch when the device boots up in End user Mode.  
If no application is specified when the Administrator Panel is closed, the MX7 Tecton reboots into Administrator mode. If a  
password has been set, but an application has not been specified, the user will be prompted for the password before enter-  
ing administration mode. The password prompt remains on the display until a valid password is entered.  
Setting  
Function  
Filename  
Default is blank. Move the cursor to the Filename text box and either type the application path or  
tap the Browse button (the … button). The standard Windows Browse dialog is displayed. After  
selecting the application from the Browse dialog, tap OK.  
Title  
Default is blank. Enter the Title to be associated with the application. The assumption is that mul-  
tiple copies of the same application may need unique titles in order to differentiate them in the  
Switchpad.  
Arguments  
Order  
Default is blank. Enter the command line parameters for the application in the Arguments text box.  
Default is 1. Enter the Order in which the application is to be loaded or presented to the end user.  
Applications are launched in lowest to highest number order and do not need to be sequential.  
Internet  
Default is Disabled. Tap the Internet check box to enable the End user Internet Explorer (EU-  
IE.EXE) When the check box is enabled, the Internet Menu and Internet Status are available. See  
the section titled End User Internet Explorer (EUIE) (page 6-4) for more details.  
Launch Button  
See following section titled Launch Button (page 6-7).  
6 - 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Setting  
Function  
Global Key  
Default is Ctrl+Spc. Select the Global Key key sequence the end user is to press when switching  
between applications. The Global Key default key sequence must be defined by the AppLock Ad-  
ministrator. The Global key is presented to the end user as the Activation key.  
Global Delay  
Input Panel  
Default is 10 seconds. Enter the number of seconds that Applications must wait before starting to  
run after reboot.  
Note: Delay (Global) may not be available in all versions of AppLock. You can simulate a Global  
Delay function by setting a delay for the first application (lowest Order) launched and  
setting the delay to 0 for all other applications.  
Default is Disabled. Enable (check) to show the Keyboard option on the Switchpad menu. When  
enabled the input panel cannot be enabled or disabled for each individual application, and is avail-  
able to the user for all configured applications.  
Clear Button  
Tap the Clear button to clear all currently displayed Filename or Application information. The  
Global settings are not cleared.  
Scroll Buttons  
Use the left and right scroll buttons to move from application setup screen to application setup  
screen. The left and right buttons update the information on the screen with the previous or next  
configured application respectively.  
6 - 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Launch Button  
When clicked, displays the Launch options panel for the Filename selected on the Administration panel.  
Note: Launch order is determined by the Order specified in the Application panel. The Order value does not have to  
be sequential.  
Auto At Boot  
Default is Enabled.  
When enabled, automatically launches (subject to the specified Delay in seconds) the application after the unit is  
rebooted. If a Delay in seconds is specified, AppLock waits for the specified period of time to expire before launch-  
ing the application. The Delay default value is 10 seconds; valid values are between 0 “no delay” and a maximum  
of 999 seconds.  
Retries  
This is the number of times the application launch will be retried if a failure occurs when the application is  
automatically launched at bootup. Valid values are between 0 (no tries) and 99 tries or -1 for infinite. Infinite  
tries ends when the application successfully launches. The default is 0 retries.  
Delay  
This timer is the time that AppLock waits prior to the initial launch of the selected application when it is auto-  
matically launched at bootup. Delay default is 10 seconds. Valid values are between 0 seconds (no delay) and  
999 seconds.  
The Auto At Boot delay is associated for each application; it will be either a value specified by the Administra-  
tor or it will be the delay default value. At startup, when a delay has been assigned for each application,  
AppLock waits for the delay associated with the first application to expire before launching the first application  
then AppLock waits for the delay associated with the second application to expire before launching the sec-  
ond application. AppLock continues in this manner until all applications are launched.  
Note: A “Global Delay” can be accomplished by setting a timed delay for the first application to be launched  
(by lowest Order number) and no delay (0 seconds) for all other applications.  
Note: Launch order is determined by the Order specified in the Application tab. The Order value does not have  
to be sequential.  
6 - 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Auto Re-Launch  
Default is Enabled.  
When enabled for a specific application. automatically re-launches it (subject to the specified Auto Re-Launch  
Delay in seconds) after it terminates. This option allows the Administrator to disable the re-launch operation.  
AppLock cannot prevent all applications from closing. When an application that AppLock cannot prevent from clos-  
ing terminates, perhaps because of an error condition, AppLock re-launches the application when this option is  
enabled.  
Note: If Allow close (page 6-8) is enabled and both Auto Re-launch and Manual (Launch) are disabled, the  
application cannot be restarted for the end user or by the end user after the application terminates.  
Retries  
Default is 0 tries. Retries is the number of times AppLock will try to re-launch the application. The retry count  
is reset after an application is successfully launched and controlled by AppLock. Valid values are between 0  
(no tries) and 99 tries or -1 for infinite. Infinite tries ends when the application successfully launches.  
Delay  
Default is 0 seconds (no delay). Delay is the amount of time AppLock waits prior to re-launching an applica-  
tion that has terminated. The delay is specified in seconds. Valid values are between 0 (no delay) and 99 sec-  
onds.  
AppLock must also be configured to automatically re-launch an application. To AppLock, application termina-  
tion by the end user is indistinguishable from application termination for any other reason.  
Manual (Launch)  
Default is Disabled.  
Enabling this option allows the end user to launch the specified application(s). Upon bootup completion an appli-  
cation with Manual enabled is listed on the Switchpad accompanied by a checkmark that indicates the application  
is currently active or available for Launching. When an application name is tapped by the end user, the application  
is launched (if inactive) and brought to the foreground.  
Applications set up with Manual (Launch) enabled may or may not be launched at bootup. This function is based  
on the application’s Auto At Boot setting. The applications have been listed as approved applications for end user  
manual launch using the Switchpad menu structure. The approved applications are listed on the Switchpad. A  
checkmark indicates the applications active status.  
When Manual (Launch) is disabled for an application, and Allow Close is enabled for the application, when the end  
user closes the specific application it is no longer available (shown) on the Switchpad.  
When Auto At Boot and Manual (Launch) are both disabled for a specific application, the application is 1) not  
placed on the list of approved applications for end user manual launch and 2) never launched, and 3) not dis-  
played on the Switchpad.  
Allow close  
Default is Disabled. When enabled, the associated application can be closed by the end user.  
This option allows the administrator to configure applications that consume system resources to be terminated if  
an error condition occurs or at the end user’s request. Error conditions may generate a topmost popup requiring  
an end user response, memory resource issues requiring an end user response, etc. Also at the administrator’s  
discretion, these types of applications can be started manually (see Manual [Launch]) by the end user.  
6 - 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Security  
Setting an Activation Hotkey  
Specify the hotkey sequence that triggers AppLock to switch between administrator and user modes and the password  
required to enter Administrator mode. The default hotkey sequence is Shift+Ctrl+A.  
A 2nd key keypress is an invalid keypress for a hotkey sequence.  
Move the cursor to the Hot Key text box. Enter the new hot key sequence by first pressing the Shift state key followed  
by a normal key. The hotkey selected must be a key sequence that the application being locked does not use. The hot-  
key sequence is intercepted by AppLock and is not passed to the application.  
Input from the keyboard or Input Panel is accepted with the restriction that the normal key must be pressed from the  
keyboard when switching modes. The hotkey sequence is displayed in the Hot key text box with <Shift>, <Alt>, and  
<Ctrl> text strings representing the shift state keys. The normal keyboard key completes the hotkey sequence. The  
hotkey must be entered via the keypad. Some hotkeys cannot be entered via the Input Panel. Also, hotkeys entered via  
the SIP (Soft Input Panel) are not guaranteed to work properly when switching operational modes.  
For example, if the <Ctrl> key is pressed followed by <A>, Ctrl+A is entered in the text box. If another key is pressed  
after a normal key press, the hotkey sequence is cleared and a new hotkey sequence is started.  
A normal key is required for the hotkey sequence and is unlike pressing the normal key during a mode switch; this key  
can be entered from the SIP when configuring the key. However, when the hotkey is pressed to switch user modes, the  
normal key must be entered from the keypad; it cannot be entered from the SIP.  
Setting a Password in the Security Panel  
Move the cursor to the Password text box. The passwords entered in the Password and Confirm Password fields must  
match. Passwords are case sensitive.  
When the user exits the Administrator panel, the two passwords are compared to verify that they match. If they do not  
match, a dialog box is displayed notifying the user of the error. After the user closes the dialog box, the Security Panel  
is displayed and the password can then be entered and confirmed again. If the passwords match, the password is  
encrypted and saved.  
6 - 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Options  
AppLock uses 3 timeout values when locking applications:  
Setting  
Explanation  
Launch  
timeout  
The time to wait for an application to initially launch before timing out. Default value is 60000 milliseconds (60  
seconds).  
Replace  
timeout  
The time to wait for an application to replace the current window with another one before timing out. Default  
value is 20000 milliseconds (20 seconds).  
Restart  
timeoutt  
The time to wait for an application to restart itself before timing out. Default value is 20000 milliseconds (20  
seconds).  
6 - 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Status  
Use the Status panel to view the log of previous AppLock operations and to configure which messages are to be recorded  
during AppLock operation.  
Status information is stored in a specific location on the storage device and in a specific logfile specified by the Administra-  
tor. For this reason, the administrator can configure the type of status information that is logged, as well as clear the status  
information.  
Move the cursor to the Filename text box and either type the logfile path or tap the Browse button (the … button). The stan-  
dard Windows OS Browse dialog is displayed. After selecting the logfile from the Browse dialog, tap OK.  
View  
Setting  
Explanation  
Error  
Error status messages are logged when an error occurs and is intended to be used by the administra-  
tor to determine why the specified application cannot be locked.  
Process  
Processing status shows the flow control of AppLock components and is mainly intended for Customer  
Support when helping users troubleshoot problems with their AppLock program.  
Extended  
All  
Extended status provides more detailed information than that logged by Process Logging.  
All messages are displayed.  
Tap the Refresh button after changing from one view level to another. The filtered records are displayed, all others are  
not displayed.  
6 - 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Log  
Note: If a level higher than Error is selected, the status should be cleared frequently by the administrator.  
In addition to the three view levels the administrator can select that all status information be logged or turn off all status  
information logging completely. The system default is ‘None’; however to reduce registry use, the administrator may  
want to select ‘None’ after verifying the configuration. Tap the Clear button to clear the status information from the reg-  
istry.  
None  
Error  
Processing  
Extended  
All  
Save As  
When the 'Save As'… button is selected, a standard 'Save As' dialog screen is displayed. Specify the path and file-  
name. If the filename exists, the user is prompted whether the file should be overwritten. If the file does not exist, it is  
created.  
AppLock Help  
Issue:  
The MX7 Tecton won’t switch from Administration mode to end user mode.  
Solution:  
If the configuration is valid for one application but not the other, the switch to end user mode fails. AppLock stays in  
Administration mode and is paused until the Administrator password is entered.  
If two copies of the same application are configured, but the application only allows one copy to run at a time, for example  
Microsoft Pocket Word and RFTerm, the switch to end user fails. AppLock stays in Administration mode and is paused  
until the Administrator password is entered.  
Issue:  
The hotkey sequence needed is not allowed. What does this mean?  
Solution:  
When the Administrator is selecting a hotkey sequence to use when switching user modes, they are not allowed to enter  
key combinations that are reserved by installed software applications. Honeywell has validated RFTerm key combinations  
ONLY.  
When RFTerm is installed on the mobile device and an RFTerm restricted key sequence is specified as a hotkey sequence  
by the Administrator, the following error message is displayed in a message box:  
Selected hotkey is not allowed. Please reenter.  
When RFTerm is not installed on the mobile device, the RFTerm keys are not restricted from use.  
Issue:  
Can’t locate the password that has been set by the administrator?  
Solution:  
Contact Technical Assistance (page 16-1) for administrator password help.  
6 - 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
AppLock Error Messages  
Any messages whose first word is an ‘ing’ word is output prior to the action described in the message. For example, “Switching  
to admin-hotkey press” is logged after the administrator has pressed the hotkey but prior to starting the switch process.  
For all operations that can result in an error, an Error level message is displayed when a failure occurs. These messages contain  
the word “failure”. These messages have a partner Extended level message that is logged which contains the word “OK” if the  
action completed successfully rather than with an error.  
For processing level messages, “Enter…” is logged at the beginning of the function specified in the message and “Exit…” is  
logged at the end (just before the return) of the function specified in the message.  
Message  
Explanation and/or corrective action  
Level  
Error reading hotkey  
The hotkey is read but not required by AppLock.  
LOG_EX  
Error reading hotkey; A hotkey is required. If there is a failure reading the hotkey, the internal factory LOG_ERROR  
using default default is used.  
App Command Line= Command line of the application being locked  
<Command line>  
LOG_PROCESSING  
App= <Application  
name>  
Name of the application being locked  
LOG_PROCESSING  
dwProcessID= <#>  
Device ID of the application being locked  
LOG_EX  
LOG_EX  
Encrypt exported key Size of encrypt export key  
len <#>  
Encrypt password  
length= <#>  
The length of the encrypted password.  
LOG_EX  
LOG_EX  
Encrypted data len  
<#>  
Length of the encrypted password  
hProcess= <#>  
Key pressed = <#>  
*****************  
Handle of the application being locked  
LOG_EX  
LOG_EX  
A key has been pressed and trapped by the hotkey processing.  
The status information is being saved to a file and the file has been opened suc- LOG_EX  
cessfully.  
Address of keyboard  
AppLock found the kbdhook.dll, but was unable to get the address of the initial- LOG_ERROR  
hook procedure failure ization procedure. For some reason the dll is corrupted. Look in the \Windows  
directory for kbdhook.dll. If it exists, delete it. Also delete AppLock.exe from the  
\Windows directory and reboot the unit. Deleting AppLock.exe triggers the Ap-  
pLock system to reload.  
Address of keyboard  
hook procedure OK  
AppLock successfully retrieved the address of the keyboard filter initialization LOG_EX  
procedure.  
Alt pressed  
Alt  
The Alt key has been pressed and trapped by the HotKey processing.  
Processing the hotkey and backdoor entry  
LOG_EX  
LOG_EX  
Application handle  
search failure  
The application being locked did not complete initialization.  
LOG_ERROR  
Application handle  
search OK  
The application initialized itself successfully  
LOG_ERROR  
Application load failure The application could not be launched by AppLock; the application could not be LOG_ERROR  
found or is corrupted.  
Backdoor message re- The backdoor keys have been pressed. The backdoor hotkeys provide a meth- LOG_PROCESSING  
ceived  
od for customer service to get a user back into their system without editing the  
registry or reloading the device.  
Cannot find kbd-  
hook.dll  
The load of the keyboard filter failed. This occurs when the dll is missing or is LOG_ERROR  
corrupted. Look in the \Windows directory for kbdhook.dll. If it exists, delete it.  
Also delete AppLock.exe from the \Windows directory and reboot the unit. De-  
leting AppLock.exe triggers the AppLock system to reload.  
Converted Pwd  
Converted password from wide to mbs.  
LOG_EX  
6 - 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Message  
Explanation and/or corrective action  
Level  
Could not create event The keyboard filter uses this event at the Administrator Control panel. The  
LOG_ERROR  
EVT_HOTKEYCHG  
event could not be created.  
Could not hook key-  
board  
If the keyboard cannot be controlled, AppLock cannot process the hotkey. This LOG_ERROR  
failure prevents a mode switch into user mode.  
Could not start thread The keyboard filter must watch for hot key changes. The watch process could LOG_ERROR  
HotKeyMon  
Ctrl after L or X  
Ctrl pressed  
Ctrl  
not be initiated.  
Processing the backdoor entry.  
LOG_EX  
The Ctrl key has been pressed and trapped by the HotKey processing.  
Processing the hotkey and backdoor entry.  
Unable to decrypt password.  
LOG_EX  
LOG_EX  
Decrypt acquire con-  
text failure  
LOG_ERROR  
Decrypt acquired con- Decryption process ok.  
text OK  
LOG_EX  
Decrypt create hash  
failure  
Unable to decrypt password.  
LOG_ERROR  
LOG_EX  
Decrypt created hash Decryption process ok.  
OK  
Decrypt failure  
Unable to decrypt password.  
LOG_ERROR  
LOG_ERROR  
Decrypt import key fail- Unable to decrypt password.  
ure  
Decrypt imported key Decryption process ok.  
OK  
LOG_EX  
Encrypt acquire con-  
text failure  
Unable to encrypt password.  
Unable to encrypt password.  
Encrypt password process successful.  
Unable to encrypt password.  
LOG_ERROR  
LOG_ERROR  
LOG_EX  
Encrypt acquire en-  
crypt context failure  
Encrypt acquired en-  
crypt context OK  
Encrypt create hash  
failure  
LOG_ERROR  
LOG_ERROR  
LOG_EX  
Encrypt create key fail- Unable to encrypt password.  
ure  
Encrypt created en-  
crypt hash OK  
Encrypt password process successful.  
Encrypt export key fail- Unable to encrypt password.  
ure  
LOG_ERROR  
LOG_ERROR  
LOG_EX  
Encrypt export key  
length failure  
Unable to encrypt password.  
Encrypt exported key Encrypt password process successful.  
OK  
Encrypt failure  
The password encryption failed.  
LOG_ERROR  
LOG_ERROR  
LOG_ERROR  
Encrypt gen key failure Unable to encrypt password.  
Encrypt generate key Unable to encrypt password.  
failure  
Encrypt get user key  
failure  
Unable to encrypt password.  
LOG_ERROR  
LOG_EX  
Encrypt get user key  
ok  
Encrypt password process successful.  
6 - 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Message  
Explanation and/or corrective action  
Level  
Encrypt hash data fail- Unable to encrypt password.  
ure  
LOG_ERROR  
Encrypt hash data  
from pwd OK  
Encrypt password process successful.  
LOG_EX  
Encrypt length failure Unable to encrypt password.  
LOG_ERROR  
LOG_ERROR  
Encrypt out of memory Unable to encrypt password.  
for key  
Encrypted data OK  
The password has been successfully encrypted.  
LOG_EX  
Enter AppLockEnum- In order for AppLock to control the application being locked so it can prevent LOG_EX  
Windows  
the application from exiting, AppLock launches the application and has to wait  
until it has created and initialized its main window. This message is logged  
when the function that waits for the application initialization is entered.  
Enter DecryptPwd  
Enter EncryptPwd  
Entering the password decryption process.  
Entering the password encryption processing.  
LOG_PROCESSING  
LOG_PROCESSING  
Enter FullScreenMode Entering the function that switches the screen mode. In full screen mode, the LOG_PROCESSING  
taskbar is hidden and disabled.  
Enter GetAppInfo  
Processing is at the beginning of the function that retrieves the application in- LOG_PROCESSING  
formation from the registry.  
Enter password dialog Entering the password dialog processing.  
LOG_PROCESSING  
LOG_PROCESSING  
Enter password time- Entering the password timeout processing.  
out  
Enter restart app timer Some application shut down before AppLock can stop it. In these cases, Ap- LOG_PROCESSING  
pLock gets notification of the exit. When the notification is received, AppLock  
starts a timer to restart the application. This message logs that the timer has  
expired and the processing is at the beginning of the timer function.  
Enter TaskbarScreen- Entering the function that switches the screen to non-full screen mode and en- LOG_PROCESSING  
Mode  
able the taskbar.  
Enter ToAdmin  
Enter ToUser  
Entering the function that handles a mode switch into admin mode.  
Entering the function that handles the mode switch to user mode  
LOG_PROCESSING  
LOG_PROCESSING  
LOG_PROCESSING  
Enter verify password Entering the password verification processing.  
Exit AppLockEnum-  
Windows-Found  
There are two exit paths from the enumeration function. This message denotes LOG_PROCESSING  
the enumeration function found the application.  
Exit AppLockEnum-  
Windows-Not found  
There are two exit paths from the enumeration function. This message denotes LOG_PROCESSING  
the enumeration function did not find the application.  
Exit DecryptPwd  
Exit EncryptPwd  
Exit FullScreenMode  
Exit GetAppInfo  
Exiting password decryption processing.  
LOG_PROCESSING  
LOG_PROCESSING  
LOG_PROCESSING  
Exiting password encryption processing.  
Exiting the function that switches the screen to full screen.  
Processing is at the end of the function that retrieved the application informa- LOG_PROCESSING  
tion from the registry.  
Exit password dialog  
Exiting password prompt processing.  
LOG_PROCESSING  
LOG_PROCESSING  
Exit password dialog- Exiting password prompt w/cancel.  
cancel  
Exit password dialog- Exiting password prompt successfully.  
OK  
LOG_PROCESSING  
Exit password timeout Exiting password timeout processing.  
LOG_PROCESSING  
LOG_PROCESSING  
Exit restart app timer  
Processing is at the end of the timer function  
Exit TaskbarScreen-  
Mode  
Exiting the function that switches the screen mode back to normal operation for LOG_PROCESSING  
the administrator.  
6 - 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Message  
Explanation and/or corrective action  
Level  
Exit ToAdmin  
Exit ToUser  
Exiting the function that handles the mode switch into admin mode.  
Exiting the user mode switch function.  
LOG_PROCESSING  
LOG_PROCESSING  
Exit ToUser-Registry  
read failure  
The AppName value does not exist in the registry so user mode cannot be en- LOG_PROCESSING  
tered.  
Exit verify password-  
no pwd set  
Exiting password verification.  
LOG_PROCESSING  
Exit verify password-  
response from dialog  
Exiting password verification.  
LOG_PROCESSING  
Found taskbar  
The handle to the taskbar has been found so that AppLock can disable it in user LOG_PROCESSING  
mode.  
Getting address of  
keyboard hook init pro-  
cedure  
AppLock is retrieving the address of the keyboard hook.  
LOG_PROCESSING  
Getting configuration  
from registry  
The AppLock configuration is being read from the registry. This occurs at ini- LOG_PROCESSING  
tialization and also at entry into user mode. The registry must be re-read at en-  
try into user mode in case the administration changed the settings of the  
application being controlled.  
Getting encrypt pwd  
length  
The length of the encrypted password is being calculated.  
LOG_EX  
Hook wndproc failure AppLock is unable to lock the application. This could happen if the application LOG_ERROR  
being locked encountered an error after performing its initialization and shut it-  
self down prior to being locked by AppLock.  
Hook wndproc of open The application is open, but AppLock cannot lock it.  
app failure  
LOG_ERROR  
Hot key event creation The Admin applet is unable to create the hotkey notification.  
failure  
LOG_ERROR  
Hot key pressed  
Hot key pressed  
Processing the hotkey and backdoor entry  
Processing the hotkey and backdoor entry  
LOG_EX  
LOG_EX  
Hot key set event fail- When the administrator changes the hotkey configuration the hotkey controller LOG_ERROR  
ure must be notified. This notification failed.  
Hotkeypressmessage The user just pressed the configured hotkey.  
received  
LOG_PROCESSING  
In app hook:WM_SIZE In addition to preventing the locked application from exiting, AppLock must also LOG_EX  
prevent the application from enabling the taskbar and resizing the application’s  
window. This message traps a change in the window size and corrects it.  
In app hook:WM_WIN- In addition to preventing the locked application from exiting, AppLock must also LOG_EX  
DOWPOSCHANGED prevent the application from enabling the taskbar and resizing the application’s  
window. This message traps a change in the window position and corrects it.  
Initializing keyboard  
hook procedure  
AppLock is calling the keyboard hook initialization.  
LOG_PROCESSING  
LOG_ERROR  
LOG_EX  
Keyboard hook initial- The keyboard filter initialization failed.  
ization failure  
Keyboard hook loaded The keyboard hook dll exists and loaded successfully.  
OK  
L after Ctrl  
Processing the backdoor entry.  
LOG_EX  
Loading keyboard  
hook  
When AppLock first loads, it loads a dll that contains the keyboard hook pro- LOG_PROCESSING  
cessing. This message is logged prior to the load attempt.  
Open failure  
The status information is being saved to a file and the file open has failed. This LOG_ERROR  
could occur if the file is write protected. If the file does not exist, it is created.  
Open registry failure  
If the Administration registry key does not exist, the switch to user mode fails LOG_ERROR  
because the AppName value in the Administration key is not available.  
6 - 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Message  
Explanation and/or corrective action  
Level  
Opened status file  
The status information is being saved to a file and the file has been opened suc- LOG_EX  
cessfully.  
Out of memory for en- Not enough memory to encrypt the password.  
crypted pwd  
LOG_ERROR  
pRealTaskbarWnd-  
Proc already set  
The taskbar control has already been installed.  
LOG_EX  
Pwd cancelled or inval- The password prompt was cancelled by the user or the maximum number of LOG_EX  
id-remain in user mode failed attempts to enter a password was exceeded.  
Read registry error-hot The hotkey registry entry is missing or empty. This is not considered an error. LOG_ERROR  
key  
The keyboard hook uses an embedded default if the value is not set in the reg-  
istry.  
Read registry failure- AppName registry value does not exist or is empty. This constitutes a failure for LOG_ERROR  
app name switching into user mode.  
Read registry failure- AppCommandLine registry entry is missing or empty. This is not considered an LOG_ERROR  
Cmd Line  
error since command line information is not necessary to launch and lock the  
application.  
Read registry failure- The Internet registry entry is missing or empty. This is not considered an error LOG_ERROR  
Internet since the Internet value is not necessary to launch and lock the application.  
Registering Backdoor The AppLock system communicates with the keyboard hook via a user defined LOG_PROCESSING  
MSG  
message. Both AppLock.exe and Kbdhook.dll register the message at initial-  
ization.  
Registering Hotkey  
MSG  
The AppLock system communicates with the keyboard hook via a user defined LOG_PROCESSING  
message. Both Applock.exe and Kbdhook.dll register the message at initializa-  
tion.  
Registry read failure at The registry has to be read when entering user mode is the AppName is miss- LOG_ERROR  
reenter user mode  
ing. This user mode entry is attempted at boot and after a hotkey switch when  
the administrator has closed the application being locked or has changed the  
application name or command line.  
Registry read failure at The registry has to be read when switching into user mode. This is because the LOG_ERROR  
reenter user mode  
administrator can change the settings during administration mode. The read of  
the registry failed which means the Administration key was not found or the Ap-  
pName value was missing or empty.  
Registry read failure  
The registry read failed. The registry information read when this message is  
logged is the application information. It the Administration key cannot be  
opened or if the AppName value is missing or empty, this error is logged. The  
other application information is not required. If the AppName value is not avail-  
able, AppLock cannot switch into user mode.  
LOG_ERROR  
Reset system work  
area failure  
The system work area is adjusted when in user mode to cover the taskbar area. LOG_ERROR  
The system work area has to be adjusted to exclude the taskbar area in admin-  
istration mode. AppLock was unable to adjust this area.  
Shift pressed  
Shift  
The Shift key has been pressed and trapped by the HotKey processing.  
Processing the hotkey and backdoor entry  
LOG_EX  
LOG_EX  
Show taskbar  
The taskbar is now being made visible and enabled.  
LOG_PROCESSING  
Switching to admin-  
backdoor  
The system is currently in user mode and is now switching to admin mode. The LOG_PROCESSING  
switch occurred because of the backdoor key presses were entered by the ad-  
ministrator.  
Switching to admin-  
hotkey press  
The system is currently in user mode and is now switching to admin mode. The LOG_PROCESSING  
switch occurred because of a hotkey press by the administrator.  
Switching to admin-kb- The keyboard hook load failed, so AppLock switches to admin mode. If a pass- LOG_PROCESSING  
dhook.dll not found  
word is specified, the password prompt is displayed and remains until a valid  
password is entered.  
Switching to admin-  
If the keyboard hook initialization fails, AppLock switches to admin mode. If a LOG_PROCESSING  
keyboard hook initial- password is specified, the password prompt is displayed and remains until a  
ization failure  
valid password is entered.  
6 - 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Message  
Explanation and/or corrective action  
Level  
Switching to admin-  
registry read failure  
See the explanation of the “Registry read failure” above. AppLock is switching LOG_PROCESSING  
into Admin mode. If a password has been configured, the prompt will be dis-  
played and will not be dismissed until a valid password is entered.  
Switching to Taskbar- In administration mode, the taskbar is visible and enabled.  
ScreenMode  
LOG_EX  
Switching to user  
mode  
The registry was successfully read and AppLock is starting the process to  
switch to user mode.  
LOG_PROCESSING  
Switching to user-hot- The system is currently in admin mode and is now switching to user mode. The LOG_PROCESSING  
key press  
switch occurred because of a hotkey press by the administrator.  
Taskbar hook failure  
AppLock is unable to control the taskbar to prevent the locked application from LOG_ERROR  
re-enabling it.  
Taskbar hook OK  
AppLock successfully installed control of the taskbar.  
LOG_EX  
Timeout looking for  
app window  
After the application is launched, AppLock must wait until the application has LOG_ERROR  
initialized itself before proceeding. The application did not start successfully  
and AppLock has timed out.  
ToUser after admin,  
not at boot  
The user mode switch is attempted when the device boots and after the admin- LOG_EX  
istrator presses the hotkey. The mode switch is being attempted after a hotkey  
press.  
ToUser after admin-  
app still open  
The switch to user mode is being made via a hotkey press and the administra- LOG_EX  
tor has left the application open and has not made any changes in the configu-  
ration.  
ToUser after admin-no If user mode is being entered via a hotkey press, the administrator may have LOG_EX  
app or cmd line  
change  
left the configured application open. If so, AppLock does not launch the appli-  
cation again unless a new application or command line has been specified; oth-  
erwise, it just locks it.  
Unable to move desk- The desktop is moved when switching into user mode. This prevents them from LOG_ERROR  
top  
being visible if the application is exited and restarted by the timer. This error  
does not affect the screen mode switch; processing continues.  
Unable to move task- The taskbar is moved when switching into user mode. This prevents them from LOG_ERROR  
bar  
being visible if the application is exited and restarted by the timer. This error  
does not affect the screen mode switch; processing continues.  
Unhook taskbar wnd- AppLock could not remove its control of the taskbar. This error does not affect LOG_ERROR  
proc failure AppLock processing  
Unhook wndproc fail- AppLock could not remove the hook that allows monitoring of the application. LOG_ERROR  
ure  
Unhooking taskbar  
In administration mode, the taskbar should return to normal operation, so Ap- LOG_EX  
pLock’s control of the taskbar should be removed.  
Unhooking wndproc  
When the administrator leaves user mode, the device is fully operational; there- LOG_EX  
fore, AppLock must stop monitoring the locked application.  
WM_SIZE adjusted  
X after Ctrl+L  
This message denotes that AppLock has readjusted the window size.  
Processing the backdoor entry.  
LOG_EX  
LOG_EX  
LOG_EX  
Ret from password  
<#>  
Return value from password dialog.  
Decrypt data len <#> Length of decrypted password.  
LOG_EX  
Window handle to  
enumwindows=%x  
The window handle that is passed to the enumeration function. This message LOG_EX  
can be used by engineering with other development tools to trouble shoot ap-  
plication lock failures.  
WM_WINDOW-  
POSCHG adjust-  
ed=%x  
Output the window size after it has been adjusted by AppLock  
LOG_EX  
6 - 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
Bluetooth Configuration  
Introduction  
Contact Technical Assistance (page 16-1) for upgrade availability if your Bluetooth panels are not the same as the panels pre-  
sented in this section.  
Discover and manage pairing with nearby Bluetooth devices.  
Setting  
Default  
Discovered Devices  
Settings  
None  
Turn On Bluetooth  
Computer is connectable  
Computer is discoverable  
Prompt if devices request to pair  
Continuous search  
Filtered Mode  
Disabled / default is Off  
Enabled  
Disabled  
Enabled  
Disabled  
Enabled  
Printer Port on COM9:  
Disabled (unchecked) by default in both Filtered and Non Fil-  
tered Modes. The option is dimmed in Non Filtered Mode.  
Logging  
Disabled  
Computer Friendly Name  
Reconnect  
[System Name]  
Report lost connection  
Report when reconnected  
Report failure to reconnect  
Clear Pairing Table on boot  
Auto Reconnect on Boot  
Auto Reconnect  
Enabled  
Disabled  
Enabled  
Disabled  
Enabled  
Enabled  
MX7 Tecton Bluetooth client icon state and paired Bluetooth device icon states change as Bluetooth devices are discovered,  
paired, connected and disconnected. There may be audible or visual signals as paired devices re-connect with the MX7 Tecton.  
The default Bluetooth setting is Off.  
The MX7 Tecton cannot be discovered by other Bluetooth devices when the Computer is discoverable option is disabled  
(unchecked) on the Settings panel.  
Other Bluetooth devices cannot be discovered if they have been set up to be Non-Discoverable or Invisible.  
When Filtered Mode is enabled, the MX7 Tecton can pair with one Bluetooth scanner and one Bluetooth printer.  
When Filtered Mode is disabled, the MX7 Tecton can pair with up to four Bluetooth devices connected at the same time.  
It is not necessary to disconnect a paired scanner and printer before a different scanner or printer is paired with the MX7  
Tecton.  
The target Bluetooth device should be as close as possible (up to 32.8 ft/10 meters Line of Sight) to the MX7 Tecton during  
the pairing process.  
Assumption: The System Administrator has Discovered and Paired targeted Bluetooth devices for the MX7 Tecton. The MX7  
Tecton operating system has been upgraded to the revision level required for Bluetooth client operation. An application (or API)  
is available that will accept data from serial Bluetooth devices.  
Initial Configuration  
1. Open the Bluetooth control panel or tap the Bluetooth icon.  
7 - 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
3. Change the Computer Friendly Name at the bottom of the Settings display. The Bluetooth MX7 Tecton default name is  
determined by the factory installed software version. Honeywell strongly urges assigning every MX7 Tecton a unique name  
(up to 32 characters) before Bluetooth Discovery is initiated.  
4. Tap or uncheck the MX7 Tecton Bluetooth options on the Settings tab and the Reconnect (page 7-8) tab.  
5. Tap the OK button to save your changes.  
Subsequent Use  
Note: MX7 Tecton Bluetooth client icon and Bluetooth device icon states change as Bluetooth devices are discovered, paired,  
connected and disconnected. A Bluetooth client icon with a red background indicates Bluetooth is active and not paired  
with any device. A device icon with a red background indicates a disconnected paired device.  
1. Tap the Bluetooth client icon to open the Bluetooth EZPair (or LXEZ Pairing) application.  
2. Tap the Bluetooth Devices tab.  
3. Tap the Discover button. When the Bluetooth client begins searching for in-range Bluetooth devices, the button name  
changes to Stop. Tap the Stop button to cancel the Discover function at any time.  
4. The discovered devices are listed in the Bluetooth Devices window.  
5. Highlight a Bluetooth device in the Discovered window and double-tap to open the device properties menu.  
6. Tap Pair as Scanner to set up the MX7 Tecton to receive scanner data.  
7. Tap Pair as Printer to set up the MX7 Tecton to send data to the printer.  
8. Tap Serial Device (when Filtered mode is disabled) to set up the MX7 Tecton to communicate with a Bluetooth serial  
device.  
9. Tap Disconnect to stop pairing with the device. Once disconnected, tap Clear to remove the device name and data from the  
MX7 Tecton Bluetooth Devices list. Select Yes at the Delete all disconnected devices? Yes / No dialog box.  
10. Upon successful pairing, the selected device may react to indicate a successful connection. The reaction may be an audio  
signal from the device, flashing LED on the device, or a dialog box is placed on the MX7 Tecton display.  
11. Whenever the MX7 Tecton is turned On, all previously paired, live, Bluetooth devices in the vicinity are paired, one at a  
time, with the MX7 Tecton. If the devices cannot connect to the MX7 Tecton before the re-connect timeout time period  
expires (default is approximately 20 seconds for each paired device) there is no indication of the continuing disconnect  
state if Report Failure to Reconnect is disabled.  
7 - 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Bluetooth Devices  
The Bluetooth Devices tab displays any device previously discovered and paired with the MX7 Tecton.  
Before Discovery  
After Discovery  
Clear Button  
Deletes all devices from the Device table that are not currently paired. A dialog box is presented Delete all disconnected  
devices?  
Tap the Yes button to remove disconnected or deleted devices from the device table. The devices are removed from the  
Device table after any reboot sequence and when EZPair (or LXEZ Pairing) is re-launched without rebooting. Tap the No  
button to make no changes.  
Discover Button  
When tapped, the Bluetooth client discovers and displays all Bluetooth devices in the vicinity. Bluetooth managed devices  
should be as close as possible in direct line of sight, with the MX7 Tecton during the Discover process.  
At the end of the Discover process, and when Filtered Mode is disabled/unchecked, serial Bluetooth devices as well as  
Bluetooth scanners and printers are displayed in the Device table. When Filtered Mode is enabled/checked, only Bluetooth  
scanners and printers are displayed in the Device table.  
7 - 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Discovering  
1. Tap the Discover button to locate all discoverable Bluetooth devices in the vicinity. The Discovery process also  
queries for the unique identifier of each device discovered.  
2. Tap the Stop Button at any time to end the Discover and Query for Unique Identifier functions. The Bluetooth  
Device List is displayed.  
Note: When an active paired device enters Suspend Mode, is turned Off or leaves the MX7 Tecton Bluetooth scanning  
range, the Bluetooth connection between the paired device and the MX7 Tecton is lost. There may be audible  
or visual signals as paired devices disconnect from the MX7 Tecton.  
Bluetooth Device List  
The discovered paired devices may or may not be identified with an icon. Discovered devices without an icon can be  
paired as a Serial device, Scanner or a Printer. The Bluetooth panel assigns an icon to the device name.  
An icon with a red background indicates the device's Bluetooth connection is inactive.  
An icon with a white background indicates the device is connected to the MX7 Tecton and the device's Bluetooth con-  
nection is active.  
Double-tap a device in the list to open the device properties menu. The target device does not need to be active.  
7 - 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Bluetooth Device Menu  
1. After the Discover button has been tapped and there are devices listed, tap on a device in the list to highlight it.  
2. Double-tap the highlighted device to display the Bluetooth Device right click menu. The Bluetooth device does not need  
to be active.  
Filtered Mode On  
Filtered Mode Off  
Right Click Menu Options  
Pair as Scanner  
Receive data from the highlighted Bluetooth scanner or Bluetooth imager.  
Pair as Printer  
Send data to the highlighted Bluetooth printer.  
Pair as Serial Device  
Communicate with the highlighted serial Bluetooth device. This option is available when Filtered Mode is disabled.  
Disconnect  
Stop the connection between the MX7 Tecton and the highlighted paired Bluetooth device.  
Delete  
Remove an unpaired device from the Bluetooth device list. The highlighted device name and identifier is removed  
from the MX7 Tecton Bluetooth Devices panel after the user taps OK.  
Properties  
View more information on the highlighted Bluetooth device.  
7 - 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Bluetooth Properties  
Data on the Bluetooth Properties panel cannot be changed by the user. The data displayed is the result of the device  
Query performed during the Discovery process.  
The Status dialog box reflects the current state of the highlighted device.  
Settings  
Note: These options can still be checked or unchecked whether Bluetooth connection is enabled or disabled.  
Turn On Bluetooth Button  
Tap the button to toggle the Bluetooth client On or Off. The button title changes from Turn Off Bluetooth to Turn On Blue-  
tooth.  
The default value is Disabled (Bluetooth client is Off).  
7 - 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Options  
Option  
Function  
Computer is connectable This option is Enabled (checked) by default.  
Disable this option to inhibit MX7 Tecton connection initiated by a Bluetooth scanner.  
Computer is discoverable This option is Disabled (unchecked) by default.  
Enable this option to ensure other devices can discover the MX7 Tecton.  
Prompt if devices request This option is Enabled (checked) by default.  
to pair  
A dialog box appears on the MX7 Tecton screen notifying the user a Bluetooth device requests  
to pair with the MX7 Tecton.  
The requesting Bluetooth device does not need to have been Discovered by the MX7 Tecton  
before the pairing request is received.  
Tap the Accept button or the Decline button to remove the dialog box from the screen.  
In some cases, if a Bluetooth device is already paired this setting cannot be changed. If this is  
the case, an error message is displayed and the option is not changed. The Bluetooth device  
must be disconnected before changing this setting.  
Continuous Search  
Filtered Mode  
This option is Disabled (unchecked) by default.  
When enabled (checked), the Bluetooth connection never stops searching for a device it has  
paired with when the connection is broken (such as the paired device entering Suspend mode,  
going out of range or being turned off). When disabled, after being enabled, the MX7 Tecton  
stops searching after 30 minutes. This option draws power from the Main Battery.  
This option is Enabled (checked) by default.  
Determines whether the Bluetooth client discovers and displays all serial Bluetooth devices in  
the vicinity (Filtered Mode is disabled/unchecked) or the discovery result displays Bluetooth  
scanners and printers only (Filtered Mode is enabled/checked).  
When Filtered Mode is disabled, the MX7 Tecton can pair with up to four Bluetooth devices.  
A Restart is required every time Filtered Mode is toggled on and off.  
Printer Port - COM9  
Logging  
This option is Disabled (unchecked) by default.  
This option assigns Bluetooth printer connection to COM9 instead of COM19. To enable this  
option, Filtered Mode must be enabled/checked.  
This option is Disabled (unchecked) by default.  
When logging is enabled, the MX7 Tecton creates bt_log.txt and stores it in the /System folder.  
Bluetooth activity logging is added to the text file as activity progresses. A bt_log_bak.txt file  
contains the data stored by bt_log.txt prior to reboot.  
During a reboot process, the MX7 Tecton renames bt_log.txt to bt_log_bak.txt. If a file already  
exists with that name, the existing file is deleted, the new bt_log_bak.txt file is added and a  
new bt_log.txt is created.  
Computer Friendly Name The name, or identifier, entered in this space by the System Administrator is used exclusively  
by Bluetooth devices and during Bluetooth communication.  
7 - 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Reconnect  
Note: These options can still be checked or unchecked whether Bluetooth connection is enabled or disabled.  
Options  
Option  
Function  
Report when connection This option is Enabled (checked) by default.  
lost  
There may be an audio or visual signal when a connection between a paired, active device is  
lost.  
A visual signal may be a dialog box placed on the display notifying the user the connection  
between one (or all) of the paired Bluetooth devices has stopped. Tap the OK button to remove  
the dialog box from the screen.  
Report when reconnected This option is Disabled (unchecked) by default.  
There may be an audio or visual signal when a connection between a paired, active device is  
made.  
A visual signal may be a dialog box placed on the display notifying the user the connection  
between one (or all) of the paired Bluetooth devices has resumed. Tap the ok button to remove  
the dialog box from the screen.  
Report failure to recon-  
nect  
This option is Enabled (checked) by default.  
The default time delay is 30 minutes. This value cannot be changed by the user.  
There may be an audio or visual signal when a connection between a paired, active device  
fails to re-connect. A visual signal may be a dialog box placed on the display notifying the user  
the connection between one (or all) of the previously paired Bluetooth devices has failed.  
Tap the X button or ok button to close the dialog box.  
Possible reasons for failure to reconnect: Timeout expired without reconnecting; attempted to  
pair with a device that is currently paired with another device; attempted to pair with a known  
device that moved out of range or was turned off; attempted to pair with a known device but  
the reason why reconnect failed is unknown.  
Clear Pairing Table on  
Boot  
This option is Disabled (unchecked) by default.  
When enabled (checked), all previous paired information is deleted upon any reboot sequence  
and no devices are reconnected.  
When enabled (checked) Auto Reconnect on Boot is automatically disabled (dimmed).  
Auto Reconnect on Boot This option is Enabled (checked) by default. All previously paired devices are reconnected  
upon any reboot sequence.  
When disabled (unchecked), no devices are reconnected upon any reboot sequence.  
7 - 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Option  
Function  
Auto Reconnect  
This option is Enabled (checked) by default. This option controls the overall mobile Bluetooth  
device reconnect behavior.  
When Auto Reconnect is disabled (unchecked), Auto Reconnect on Boot is automatically dis-  
abled and dimmed.  
When Auto Reconnect is disabled (unchecked), no devices are reconnected in any situation.  
The status of Auto Reconnect on Boot is ignored and no devices are reconnected on boot. The  
status of Clear Pairing Table on Boot controls whether the pairing table is populated on boot.  
When Auto Reconnect is enabled (checked) and Auto Reconnect on Boot is disabled (un-  
checked), devices are not reconnected on boot, but are reconnected in other situations (ex-  
ample: return from out-of-range).  
When Auto Reconnect is enabled (checked) and Clear Pairing Table on Boot is enabled  
(checked), devices are not reconnected on boot, but are reconnected in other situations (ex-  
ample: return from out-of-range). The pairing table is cleared on boot. The status of Auto Re-  
connect on Boot is ignored and the option is automatically disabled (unchecked) and dimmed.  
About  
This panel lists the pre-assigned Computer Friendly Name (that other devices may discover during their Discovery and Query  
process), the Bluetooth client MAC address, and software version levels. The data cannot be edited by the user.  
Easy Pairing and Auto-Reconnect  
The Bluetooth module can establish relationships with new devices after the user taps the Discover button. It can auto-recon-  
nect to devices previously known but which have gone out of range and then returned within range.  
Note: Configuration elements are persistent and stored in the registry.  
Setup the Bluetooth module to establish how the user is notified by easy pairing and auto-reconnect events.  
AppLock, if installed, does not stop the end-user from using the Bluetooth application, nor does it stop other Bluetooth-enabled  
devices from pairing with the MX7 Tecton while AppLock is in control.  
7 - 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Bluetooth Indicators  
The Bluetooth icon state changes as Bluetooth devices are discovered, paired, connected and disconnected.  
There may be audible or visual signals as paired devices re-connect with the MX7 Tecton.  
Taskbar Icon  
Legend  
MX7 Tecton is connected to one or more of the targeted Bluetooth device(s).  
MX7 Tecton is not connected to any Bluetooth device.  
MX7 Tecton is ready to connect with any Bluetooth device.  
MX7 Tecton is out of range of all paired Bluetooth device(s). Connection is inactive.  
Note: When an active paired device enters Suspend Mode, is turned Off or leaves the MX7 Tecton Bluetooth scan range, the  
Bluetooth connection between the paired device and the MX7 Tecton is lost. There may be audible or visual signals as  
paired devices disconnect from the MX7 Tecton.  
AppLock, if installed, does not stop the end-user from using Bluetooth applications, nor does it stop authorized Bluetooth-  
enabled devices from pairing with the MX7 Tecton while AppLock is in control.  
Bluetooth Bar Code Reader Setup  
Refer to the Bluetooth scanner manufacturer’s User Guide; it may be available on the manufacturer’s web site. Contact  
Technical Assistance (page 16-1) for Bluetooth product help.  
Introduction  
Honeywell supports several different types of bar code readers. This section describes the interaction and setup for a  
mobile Bluetooth laser scanner or laser imager connected to the MX7 Tecton using Bluetooth functions.  
Prerequisites:  
The MX7 Tecton must have the Bluetooth hardware and software installed. An operating system upgrade may be  
required. Contact Technical Assistance for details.  
If the MX7 Tecton has a Bluetooth address identifier bar code label affixed, then Bluetooth hardware and software are  
installed.  
The mobile Bluetooth laser scanner / laser imager battery is fully charged.  
The MX7 Tecton main battery is fully charged. Alternatively, the MX7 Tecton may be cabled to AC/DC power.  
Important: The bar code numbering examples in this segment are not real and should not be created or scanned with a  
Bluetooth scanner.  
Open the Bluetooth control panel or tap the Bluetooth icon.  
Locate the bar code label, similar to the one shown above, attached to the MX7 Tecton. The label is the Bluetooth address  
identifier for the MX7 Tecton.  
The Bluetooth mobile scanner requires this information before discovering, pairing, connecting or disconnecting can occur.  
The MX7 Tecton Bluetooth address identifier label should be protected from damage (rips, tears, spills, soiling, erasure,  
etc.) at all times. It may be required when pairing, connecting, and disconnecting new Bluetooth bar code readers.  
7 - 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
MX7 Tecton with Label  
If the MX7 Tecton has a Bluetooth address bar code label attached, follow these steps:  
1. Scan the Bluetooth address bar code label, attached to the MX7 Tecton, with the Bluetooth mobile scanner.  
2. If this is the first time the Bluetooth mobile scanner has scanned the MX7 Tecton Bluetooth label, the devices are  
paired. See Bluetooth Reader Beep and LED Indications (page 7-12). If the devices do not pair successfully, go to the  
next step.  
3. Open the Bluetooth control panel.  
4. Tap Discover. Locate the Bluetooth mobile scanner in the Discovery panel.  
5. Double-tap the stylus on the Bluetooth mobile scanner. The right-mouse-click menu appears.  
6. Select Pair as Scanner to pair the MX7 Tecton with the Bluetooth mobile scanner.  
The devices are paired. The Bluetooth mobile bar code reader responds with a series of beeps and an LED flashes.  
Note: After scanning the MX7 Tecton Bluetooth label, if there is no beep and no LED flash from the Bluetooth mobile device,  
the devices are currently paired.  
MX7 Tecton without Label  
If the MX7 Tecton Bluetooth address bar code label does not exist, follow these steps to create a unique Bluetooth address  
bar code for the MX7 Tecton:  
1. First, locate the MX7 Tecton Bluetooth client MAC Address on the EZPair (or LXEZ Pairing) About panel.  
2. Next, create a Bluetooth address bar code label for the MX7 Tecton. Free bar code creation software is available for  
download on the world wide web. Search using the keywords “bar code create”.  
3. The format for the bar code label is as follows:  
Bar code type must be Code 128.  
FNC3 character followed by string Uppercase L, lowercase n, lowercase k, uppercase B and then the Bluetooth  
address (12 hex digits, no colons). For example, LnkB0400fd002031.  
4. Create and print the label.  
5. Scan the MX7 Tecton Bluetooth address bar code label with the Bluetooth bar code reader.  
The devices are paired. The Bluetooth bar code reader responds with a series of beeps and LED flashes.  
Note: After scanning the MX7 Tecton Bluetooth label, if there is no beep and no LED flash from the Bluetooth device, the  
devices are currently paired.  
7 - 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Bluetooth Reader Beep and LED Indications  
Bluetooth Mobile Device Beep Type  
Beep Type from Bluetooth Device  
Acknowledge label  
Label rejected  
Behavior  
1 beep  
2 beeps at low frequency  
Beep will sound high-low-high-low  
Beep will sound low-medium-high  
Beep will sound high-low-high-low  
Transmission error  
Link successful  
Link unsuccessful  
Bluetooth Mobile Device LED  
LED on Bluetooth Device  
Yellow LED blinks at 2 Hz  
Off  
Behavior  
Linking in progress  
Disconnected or unlinked  
Bluetooth transmission in progress  
Yellow LED blinks at 50 Hz  
Yellow LED blinks at the same rate as the paging beep Paging  
(1 Hz)  
Green LED blinks once a second  
Disabled indication  
Upon startup, if the Bluetooth mobile scanner sounds a long tone, this means the scanner has not passed its automatic Selftest  
and has entered isolation mode. If the scanner is reset, the sequence is repeated. Contact Technical Assistance (page 16-1) if  
you need help.  
Bluetooth Printer Setup  
The Bluetooth managed printer should be as close as possible, in direct line of sight, with the MX7 Tecton during the pairing pro-  
cess.  
1. Open the Bluetooth control panel on the MX7 Tecton.  
2. Tap Discover. Locate the Bluetooth printer in the Discovery panel.  
3. Tap and hold the stylus (or double-tap) on the Bluetooth printer until the right-mouse-click menu appears.  
4. Select Pair as Printer to pair the MX7 Tecton with the Bluetooth managed printer.  
The devices are paired. The Bluetooth managed printer may respond with a series of beeps or LED flashes.  
Refer to the Bluetooth managed printer manufacturer User's Guide; it may be available on the manufacturer’s web site. Contact  
Technical Assistance (page 16-1) for Bluetooth mobile device help.  
Note: If there is no beep or no LED flash from the Bluetooth managed printer, the MX7 Tecton and the printer are currently  
paired.  
7 - 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
8
Data Collection Wedge  
Introduction  
Set scanner/imager keyboard wedge parameters, enable or disable symbologies from being scanned, scanner icon appear-  
ance, active scanner port, and scan key settings. Assign baud rate, parity, stop bits and data bits for available COM ports. Scan-  
ner parameters apply to the MX7 Tecton integrated scanner/imager only. Bar code manipulation parameters apply to bar codes  
scanned by the MX7 Tecton integrated scanner/imager engine.  
Scanner configuration can be changed using the Data Collection settings panels or via the API functions. While the changed  
configuration is being read, the Scanner LED is solid amber. The scanner is not operational during the configuration update.  
The MX7 Tecton has one integrated bar code scanner/imager port. Only one scan engine is installed at a time. Scan engines  
are not “hot swappable”. The MX7 Tecton may have one of the following integrated bar code decoding engines:  
Short Range Laser Scanner, 955I  
Base Laser Scanner, 955E  
Multi-Range “LORAX” Laser, 1524ER  
Hand Held Products 2D Area Imager, 5300  
Honeywell Laser Scanner, N43XX  
Honeywell Laser Scanner, N73XX  
Note: Identify the Scan Engine: Open the Data Collection application panel on the MX7 Tecton. Tap the About tab. The type of  
integrated scan engine is shown in the Scanner segment.  
The integrated scan engine activates when the Scan button on the front of the MX7 Tecton is depressed or when the trigger on  
an installed trigger handle is depressed.  
Symbol or Honeywell scanner  
Refer to the Integrated Scanner Programming Guide for instruction on configuring specific scanner/imager parameters by  
using the MX7 Tecton to scan engine-specific setup bar codes in the guide.  
Note: Base Laser Scanner, 955E does not support aim mode. Any attempt to adjust the aiming beam using 955E  
programming bar codes will fail. The Base Laser scanner does not decode Codablock, Code93i or Telepen  
symbologies.  
Hand Held Products Imager  
Use the (Hand Held Products) HHP Products button on the Data Options tab and the Advanced button available on many of  
the individual Symbology Settings screens to configure the Hand Held Products Imager. There are no configuration bar  
codes for this imager.  
8 - 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Data Processing Overview  
Bar code data processing involves several steps. Some steps may be skipped during the processing depending on user selec-  
tions on the Symbology Settings panels. The steps are presented below in the order they are performed on the scanned data.  
1. Scanned data is tested for a code ID and length (Min/Max). If it matches, it is processed per the rules in place for that sym-  
bology. If the scan does not meet the criteria for that symbology, it is processed based on the settings for All. If a code ID is  
not found, the bar code data is processed based on the settings for All.  
2. If the symbology is disabled, the scan is rejected.  
3. Strip leading data bytes unconditionally.  
4. Strip trailing data bytes unconditionally.  
5. Parse for, and strip if found, Data Options strings.  
6. Replace any control characters with string, as configured.  
7. Add prefix string to output buffer.  
8. If Code ID is not stripped, add saved code ID from above to output buffer.  
9. Add processed data string from above to output buffer.  
10. Add suffix string to output buffer.  
11. Add a terminating NUL to the output buffer, in case the data is processed as a string.  
12. If key output is enabled, start the process to output keys. If control characters are encountered:  
If Translate All is set, key is translated to CTRL + char, and output.  
If Translate All is not set, and key has a valid VK code, key is output.  
Otherwise, key is ignored (not output).  
13. If key output is disabled, a windows message is broadcast to notify listening applications that data is available.  
The manipulated data is ready to be read by applications.  
Note: When returning scanner or imager to factory default settings: After scanning the scanner-engine-specific bar code to reset  
all scanner parameters to factory default settings (i.e., Reset All, Set Factory Defaults, Default Settings, etc.), the next  
step is to open the Data Collection settings panel. Tap OK and close the Data Collection panel. This action will  
synchronize all scanner formats for your device. Another option you can use to reset the Data Collection panel is to scan  
the LXEReset bar code (for Symbol and Hand Held Products scan engines) or the Reset bar code (for the N43XX and  
N73XX Laser Scanners). The LXEReset and Reset bar codes are located in the Integrated Scanner Programming Guide.  
8 - 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Main  
The Data Collection Wedge supports up to three concurrent data collection devices. For example, the internal scanner could be  
used to collect data at the same time a Bluetooth scanner is paired and/or a serial device is attached to COM1. The MX7 Tecton  
must be in a desktop cradle to use a tethered scanner.  
Setting  
Default  
Disabled  
Internal  
Device 1  
Device 2  
Device 3  
Disabled  
Disabled  
Enabled  
Disabled  
1 second  
Output  
Send Key Messages  
Scan Mode - Continuous  
Scan Mode - Timeout between same symbol  
Device 1 – Internal. Radio button allows scanner input/output on Device 1 (scan key or trigger).  
Device 2 – Output is enabled when COM1 is enabled on this port.  
Device 3 – Output is enabled when COM1 is enabled on this port.  
Note: Since Internal is the default setting for Device 2, a Bluetooth scanner can be paired with the Wedge using EZ Pair (or  
LXEZ Pairing) on Device 1 without disabling the internal scanner.  
Panel showing options for Symbol or Honeywell scan engine Panel showing options for any other type of scan engine  
Output – When Output is enabled, data is received from the scanner and processed via the wedge but an application can also  
open the WDG0: device and write data to it. An example is when a printer is connected to the same COM port as the scanner  
via a switch. Data can be written to the WDG device and is redirected to the associated COM port. The application must open  
the WDG0: port, not the COMx: port as the Wedge has exclusive rights to the COM port. If Output is not enabled, the WDG0:  
port can still be opened, but any attempts to write to that port fail.  
Adjust the settings and tap ok to save the changes. The changes take effect immediately.  
8 - 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Continuous Scan Mode  
Note: Do not scan decoder engine configuration bar codes when Continuous scan mode is on. Configuration bar codes do  
not decode when scanned while Continuous Mode is On.  
Continuous scan mode is only available if the MX7 Tecton is equipped with a Symbol or a Honeywell scanner. Continuous  
scan mode draws power from the main battery every time a scan read/decode sequence is performed.  
Enabling Continuous Scan Mode will ensure the laser is always on and decoding.  
Caution: Laser beam is emitted continuously. Do not look or stare into the laser beam.  
!
Set the Timeout between same symbol to a value sufficient to prevent the beeper from continuously beeping when a sym-  
bol is left in the scanner’s field of view.  
If trigger mode, power mode, or timeout between same symbol parameters are changed using external configuration bar  
codes in the Integrated Scanner Programming Guide, the operating system automatically restores the parameters to their  
programmed settings upon a cold boot and/or any change made in the Data Collection settings.  
When the scanner is in continuous mode the trigger and scan buttons function as a scanner On/Off switch.  
The scanner red LED will always be off in continuous mode. The audio beeps and green LED function the same as they do  
for normal trigger mode.  
Switching to and from continuous and normal trigger modes is in effect after upon tapping the ok button and waiting for the  
amber scan LED to go out. A reboot is not required or necessary.  
COM1  
Setting  
Baud Rate  
Data Bits  
Stop Bits  
Parity  
Default  
9600  
8
1
None  
Integrated laser scanner default values are 9600 Baud, 8 data bits, 1 stop bit and No parity.  
If these values are changed, the default values are restored after a cold boot or after re-imaging the OS.  
8 - 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
COM1 does not support 5V switchable power on Pin 9 for tethered scanners.  
Notification  
Use this panel to toggle internal scanner sounds on and off. Internal scanner sound, by default, is enabled.  
Setting  
Default  
Enabled  
Off  
Enable Internal Scanner Sound  
Good Scan Vibration  
Bad Scan Vibration  
Off  
Vibration  
Enable Good scan vibration or Bad scan vibration when a tactile response on a good scan or bad scan is desired. Scan  
sounds are accompanied by a tactile response when the internal scanner Sound parameter is enabled.  
Enable short, medium or long duration for each selection (good scan and bad scan).  
Adjust the settings and tap ok to save the changes. The changes take effect immediately.  
8 - 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Since the Data Collection Wedge uses the operating system interface to emit sounds/beeps, if the volume/vibrate icon is  
set to anything other than On, Wedge beeps do not sound. Wedge vibration is not affected by the System setting.  
Beep/sound volume and vibration can be quickly toggled on and off by tapping the volume icon on the Windows Mobile  
Today screen.  
8 - 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Data Options  
Bar code manipulation parameter settings on this tab are applied to the incoming data resulting from successful bar code scans  
sent to the MX7 Tecton for processing.  
Note: The Data Options tab contains only those options available for one type of decoding engine.  
Setting  
Default  
None  
Enable Code ID  
Symbology Settings  
Control Character Translate All  
Custom IDs  
All  
Disabled  
Name blank  
HHP Properties (Hand Held Products)  
Options Disabled:  
Centering  
DecodeMode  
LinearRange  
AimTimer  
LeaveLightsOn  
The Data Options tab contains several options to control bar code processing. Options include:  
Defining custom Code IDs  
Disable processing of specified bar code symbologies  
Rejecting bar code data that is too short or too long  
Stripping characters including Code ID, leading or trailing characters and specified bar code data strings  
Replacing control characters  
Adding a prefix and a suffix  
For MX7 Tecton with Symbol or Honeywell engine:  
Data Collection Wedge can only enable or disable the processing of a bar code inside the Wedge software. Enabling or dis-  
abling a specific bar code symbology at the scanner/imager is done manually using the configuration bar codes in the Integrated  
Scanner Programming Guide.  
For MX7 Tecton with Hand Held Products Imager:  
Data Collection Wedge enables or disables the bar code at the imager as well as enabling or disabling the bar code processing  
in the Wedge software..  
8 - 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Panel for a Hand Held Products scan engine  
Panel for any other type of scan engine  
The HHP Properties button is only present if the MX7 Tecton is equipped with a Hand Held Products (HHP) imager.  
1. Choose an option in the Enable Code ID drop-down box:  
None  
AIM  
Honeywell  
Symbol  
HHP  
Custom.  
2. The Symbology screen is displayed.  
Enable Code ID  
This parameter programs the internal scanner to transmit the specified Code ID and/or determines the type of bar code  
identifier being processed. If the scanner being configured is not an integrated scanner, the scanner driver expects that the  
setting has been programmed into the scanner externally, and that the data will be coming in with the specified Code ID  
attached.  
Transmission of the Code ID is enabled at the scanner for all bar code symbologies, not for an individual symbology. Code  
ID is sent from the scanner so the scanner driver can discriminate between symbologies.  
When Strip: Code ID (see Symbology panel) is not enabled, the code ID is sent as part of the bar code data to an  
application.  
When Strip: Code ID (see Symbology panel) is enabled, the entire Code ID string is stripped (i.e., treated as a Code ID).  
UPC/EAN Codes only: The Code ID for supplemental bar codes is not stripped.  
When Enable Code ID is set to AIM, Symbol or HHP, Custom Code IDs appear at the end of the list of standard Code IDs.  
When Enable Code ID is set to Custom, Custom Code IDs replace the list of standard Code IDs.  
Symbol equipped devices are configured using configuration bar codes, When Enable Code ID is set to Custom, AIM or  
Symbol Code IDs must be added to the end of the Custom Code ID. For example, if a Custom Code ID ‘AAA’ is created  
to be read in combination with an AIM ID for Code 39 ‘]A1’, the Custom Code ID must be entered with the AIM ID code  
first then the Custom Code ID : ]A1AAA.  
When Enable Code ID is set to None, Code IDs are ignored.  
Custom symbologies appear at the end of the list in the Symbology dialog, but will be processed at the beginning of the  
list in the scanner driver. This allows custom IDs, based on actual code IDs, to be processed before the Code ID.  
The external scanner operation cannot be controlled by the MX7 Tecton scanner driver; therefore, a ‘good’ beep may be  
sounded from the external scanner even if a bar code from an external scanner is rejected because of the configuration  
specified. The MX7 Tecton will still generate a ‘bad’ scan beep, to indicate the bar code has been rejected.  
8 - 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Enable Code ID Options  
Depending on the model of the scanner installed, some combination of the following IDs are listed.  
None  
Programs the internal scanner to disable transmission of a Code ID. The only entry in the Symbology popup list is  
All.  
AIM  
Programs the internal scanner to transmit the AIM ID with each bar code. The combo box in the Symbology panel  
is loaded with the known AIM ID symbologies for that platform, plus any configured Custom code IDs.  
Honeywell  
Programs the internal scanner to transmit the Honeywell ID with each bar code. The combo box in the Symbology  
panel is populated with the known Honeywell ID symbologies for that platform, plus any configured Custom code  
IDs.  
Symbol  
Programs the internal scanner to transmit the Symbol ID with each bar code. The combo box in the Symbology  
panel is loaded with the known Symbol ID symbologies for that platform, plus any configured Custom Code IDs.  
HHP (Hand Held Products)  
The imager always transmits the HHP ID with each bar code, so the Code ID is used to identify the bar code being  
processed. The combo box in the Symbology control panel is populated with the known HHP ID symbologies for  
that platform, plus any configured Custom code IDs.  
Custom  
Does not change the scanner’s Code ID transmission setting. The combo box in the Symbology panel is loaded  
with any configured Custom Code IDs.  
Enable Code ID Buttons  
Symbology Settings  
Individually enable or disable a bar code from being scanned, set the minimum and maximum size bar code to  
accept, strip Code ID, strip data from the beginning or end of a bar code, or (based on configurable Barcode Data)  
add a prefix or suffix to a bar code before transmission.  
Ctrl Char Mapping  
Define the operations the Wedge performs on control characters (values less than 0x20) embedded in bar codes.  
Custom Identifiers  
Defines an identifier that is at the beginning of bar code data which acts as a Code ID. After a Custom Identifier is  
defined, Symbology Settings can be defined for the identifier just like standard Code IDs.  
HHP Properties  
Set properties for a Hand Held Products imager including centering, mode, range, AIM timer and light behavior.  
Note that the HHP Properties button is only present if the MX7 Tecton is equipped with a Hand Held Products  
imager.  
Symbology Settings  
The Symbology selected in the Symbology drop down list defines the symbology for which the data is being configured.  
The features available on the Symbology panel include the ability to:  
individually enable or disable a bar code from scanning,  
set the minimum and maximum size bar code to accept,  
strip Code ID,  
strip data from the beginning or end of a bar code,  
or (based on configurable Barcode Data) add a prefix or suffix to a bar code.  
8 - 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
The Code ID drop down box only filters the available symbologies in the Symbology drop down box by the selected Code  
ID. This Code ID box does not enable or disable the Code ID as that function is controlled by the Enable Code ID box on the  
Data Options tab.  
The Symbology drop down box contains all symbologies supported based on the Code ID selected above. An asterisk  
appears in front of symbologies that have already been configured or have been modified from the default value.  
Each time a Symbology is changed, the settings are saved as soon as the ok button is clicked. Settings are also saved  
when a new Symbology is selected from the Symbology drop down list.  
Panel for HHP scan engine  
Panel for Honeywell scan engine  
Clear Button  
This button will erase any programmed overrides, returning to the default settings for the selected symbology.  
If Clear is pressed when All is selected as the symbology, a confirmation dialog appears. Tap the Yes button and all  
symbologies are reset to their factory defaults, and all star (*) indications are removed from the list of Symbologies.  
Advanced Button  
If there are advanced configuration options for the selected symbology, an Advanced button is displayed in the lower  
right corner of the panel. Not all bar code symbologies have configuration parameters so the Advanced button is not  
present for all symbologies.  
Because the Hand Held Products imager does not support configuration bar codes, the Advanced button function  
allows configuration parameters to be set for many of the supported bar codes.  
Processing Order  
The order in which these settings are processed are:  
Min / Max  
Code ID  
Leading / Trailing  
Barcode Data  
Prefix / Suffix  
Note: When Enable Code ID is set to None on the Data Options tab and All is selected in the Symbology field, Enable  
and Strip Code ID on the Symbology panel are dimmed and the user is not allowed to change them, to prevent  
deactivating the scanner completely.  
8 - 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
When All is selected in the Symbology field and the settings are changed, the settings in this dialog become the  
defaults, used unless overwritten by the settings for individual symbologies. This is also true for Custom IDs, where the  
code IDs to be stripped are specified by the user.  
Note: In Custom mode on the Data Options tab, any Code IDs not specified by the user will not be stripped, because  
they will not be recognized as Code IDs.  
If a specific symbology's settings have been configured, a star (*) will appear next to it in the Symbology drop down  
box, so the user can tell which symbologies have been modified from their defaults.  
If a particular symbology has been configured, the entire set of parameters from that symbologies screen are in effect  
for that symbology. In other words, either the settings for the configured symbology will be used, or the default settings  
are used, not a combination of the two.  
If a symbology has not been configured (does not have an * next to it) the settings for All are used which is not neces-  
sarily the default.  
Enable, Min, Max  
Enable  
This check box enables (checked) or disables (unchecked) the symbology field.  
The scanner driver searches the beginning of the bar code data for the type of ID specified in the Data Options tab  
-- Enable Code ID field plus any custom identifiers.  
When a code ID match is found as the scanner driver processes incoming bar code data, if the symbology is dis-  
abled, the bar code is rejected. Otherwise, the other settings in the dialog are applied and the bar code is pro-  
cessed.  
If the symbology is disabled, all other fields on this dialog are dimmed.  
If there are customized settings, uncheck the Enable check box for the All symbology. This results in disabling all  
symbologies except the customized ones.  
Min  
This field specifies the minimum length that the bar code data (not including Code ID) must meet to be processed.  
Any bar code scanned that is less than the number of characters specified in the Min field is rejected. The default  
for this field is 1.  
Max  
This field specifies the maximum length that the bar code data (not including Code ID) can be processed. Any bar  
code scanned that has more characters than specified in the Max field is rejected. The default for this field is All  
(9999).  
If the value entered is greater than the maximum value allowed for that symbology, the maximum valid length is  
used instead.  
Strip Leading/Trailing Control  
This group of controls determines what data is removed from the collected data before the data is buffered for the  
application. When all values are set, Code ID takes precedence over Leading and Trailing; Barcode Data stripping is  
performed last. Stripping occurs before the Prefix and Suffix are added, so does not affect them.  
If the total number of characters being stripped is greater than the number of characters in the collected data, it  
becomes a zero byte data string.  
If, in addition, Strip Code ID is enabled, and no prefix or suffix is configured, the processing will return a zero-byte data  
packet, which will be rejected.  
8 - 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
The operation of each type of stripping is defined below:  
Leading  
This strips the number of characters specified from the beginning of the collected data (not including Code ID).  
The data is stripped unconditionally. This action is disabled by default.  
Trailing  
This strips the number of characters specified from the end of the collected data (not including Code ID). The data  
is stripped unconditionally. This action is disabled by default.  
Code ID  
Strips the Code ID based on the type code ID specified in the Enable Code ID field in the Data Options tab. By  
default, Code ID stripping is enabled for every symbology (meaning code IDs will be stripped, unless specifically  
configured otherwise).  
Bar Code Data Match List  
The Barcode Data Panel is used to strip data that matches the entry in the Match list from the bar code. Enter the data  
to be stripped in the text box and tap the Insert or Add button. The entry is added to the Match list.  
To remove an entry from the Match list, highlight the entry in the list and tap the Remove button.  
Tap ok to store any additions, deletions or changes.  
Bar Code Data Match Edit Buttons  
Add  
Entering data into the text entry box enables the Add button. Tap the Add button and the data is added to the  
next empty location in the Custom ID list.  
Insert  
Tap on an empty line in the Custom ID list. The Add button changes to Insert. Enter data into both the Name  
and ID Code fields and tap the Insert button. The data is added to the selected line in the Custom IDs list.  
Edit  
Double tap on the item to edit. Its values are copied to the text boxes for editing. The Add button changes to  
Replace. When Replace is tapped, the values for the current item in the list are updated.  
8 - 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Clear All  
When no item in the Custom IDs list is selected, tapping the Clear All button clears the Custom ID list and any  
text written (and not yet added or inserted) in the Name and ID Code text boxes.  
Remove  
The Clear All button changes to a Remove button when an item in the Custom IDs list is selected. Tap the  
desired line item and then tap the Remove button to delete it. Line items are Removed one at a time. Con-  
tents of the text box fields are cleared at the same time.  
Notes  
Prefix and Suffix data is always added on after stripping is complete, and is not affected by any stripping  
settings.  
If the stripping configuration results in a 0 length bar code, a good beep will still be emitted, since bar code  
data was read from the scanner.  
Match List Rules  
The data in the match list is processed by the rules listed below:  
Strings in the list will be searched in the order they appear in the list. If the list contains ABC and AB, in that  
order, incoming data with ABC will match first, and the AB will have no effect.  
When a match between the first characters of the bar code and a string from the list is found, that string is  
stripped from the bar code data.  
Processing the list terminates when a match is found or when the end of the list is reached.  
If the wildcard * is not specified, the string is assumed to strip from the beginning of the bar code data. The string  
ABC* strips off the prefix ABC. The string *XYZ will strip off the suffix XYZ. The string ABC*XYZ will strip both  
prefix and suffix together. More than one * in a configuration string is not allowed. (The User Interface will not  
prevent it, but results would not be as expected, as only the first * is used in parsing to match the string.)  
The question mark wildcard ? may be used to match any single character in the incoming data. For example,  
the data AB?D will match ABCD, ABcD, or AB0D, but not ABDE.  
The data collected is saved per symbology configured. The Symbology selected in the Symbologies dialog  
defines the symbology for which the data is being configured.  
Note that the Code ID (if any are configured) is ignored by this dialog, regardless of the setting of Strip: Code ID  
in the Symbologies dialog. According to the sequence of events (specified above), the Code ID must not be  
included in the bar code data being matched, because when the matching test occurs, the Code ID has already  
been stripped. If Strip Code ID is disabled, then the bar code data to match must include the Code ID. If Strip  
Code ID is enabled, the data should not include the Code ID since it has already been stripped.  
Add Prefix/Suffix Control  
Note: Non-ASCII equivalent keys in Key Message mode are unavailable in this option. Non-ASCII equivalent keys  
include the function keys (e.g., <F1>), arrow keys, Page up, Page down, Home, and End.  
Use this option to specify a string of text, hex values or hat encoded values to be added to the beginning (prefix) or the  
end (suffix) of the bar code data. Up to 19 characters can be included in the string. The string can include any charac-  
ter from the keyboard plus characters specified by hex equivalent or entering in hat encoding. See Hat Encoding  
(page 8-39) for a list of characters with their hex and hat-encoded values.  
Using the Escape function allows entering literal hex and hat values.  
Add Prefix  
To enable a prefix, check the Prefix check box and enter the desired string in the textbox. The default is disabled  
(unchecked) with a blank text string.  
When bar code data is processed, the Prefix string is sent to the output buffer before any other data. Because all  
stripping operations have already occurred, stripping settings do not affect the prefix.  
8 - 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
The prefix is added to the output buffer for the Symbology selected from the pulldown list. If ‘All’ is selected, the  
prefix is added for any symbology that has not been specifically configured.  
Add Suffix  
To enable a suffix, check the Suffix check box and enter the desired string in the textbox. The default is disabled  
(unchecked) with a blank text string.  
When bar code data is processed, the Suffix string is sent to the output buffer after the bar code data. Because all  
stripping operations have already occurred, stripping settings do not affect the suffix.  
The suffix is added to the output buffer for the Symbology selected from the pulldown list. If ‘All’ is selected, the  
suffix is added for any symbology that has not been specifically configured.  
Symbologies  
The Code ID drop-down box filters the available symbologies, in the Symbology drop down box, by the selected Code ID.  
When a Honeywell scan engine is installed, AIM, Custom and Honeywell symbologies are displayed.  
When a Hand Held Products imager scan engine is installed, AIM, Custom and HHP symbologies are displayed. HHP does  
not support Symbol IDs.  
When a Symbol scan engine is installed, AIM, Custom and Symbol symbologies are displayed. Symbol does not support  
HHP IDs (Hand Held Products) or Honeywell IDs.  
AIM Symbologies  
Note: When the integrated scan engine is a Honeywell or Symbol scan engine, AIM IDs apply, but Advanced properties  
do not and the Advanced button is not available.  
Symbol Engine  
All  
Honeywell Engine  
All  
Aztec  
Codabar  
Codabar  
Code 11  
Code 128  
Code 39  
Code 128  
Code 39  
UPC/EAN  
Code 49  
Code 93  
EAN/UPC  
GS1 Databar  
Interleaved 2 of 5  
Matrix 2 of 5  
MSI  
Code 93  
Data Matrix  
Interleaved 2 of 5  
MaxiCode  
MicroPDF  
PDF417  
NEC 2 of 5  
Plessey  
PosiCode  
QR Code  
GS1 DataBar  
Str2of5  
Telepen  
Trioptic Code  
China Post  
The Data Collection Wedge does not manage mutually exclusive option selections. The user is responsible for under-  
standing the options that can co-exist for the data collection device. The documentation provided from the manufac-  
turer of the scanner/imager being managed describes the interaction between symbologies and their configurations.  
8 - 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
HHP Symbologies  
Advanced properties are available when an integrated Hand Held Products imager is installed in the MX7 Tecton.  
Advanced properties are applicable regardless of the ID type selected (AIM or HHP). HHP = Hand Held Products.  
Not all HHP symbologies have Advanced options. Symbologies with Advanced options are documented on the follow-  
ing pages. Symbologies with Advanced button function are marked with an asterisk in the table below.  
Symbology  
All  
Composite  
Coupon  
ISBT-1  
RSS  
AUSPOST  
JapanPost  
Planet *  
Aztec  
Matrix 2 of 5  
Mesa *  
Strt25  
BPO  
DataMatrix  
EAN *  
Strt32  
Codabar *  
Codablock  
Code 11 *  
Code32  
Code 39 *  
Code 49  
Code 93  
Code 128  
MSI *  
Telepen *  
TLC  
DutchPost  
ChinaPost  
Code16K  
Usps4cb  
Maxicode  
MicroPDF  
OCR *  
EAN13 *  
EAN128  
GenCode128  
IATA25  
Other  
PDF417  
Plessey  
Posicode *  
Postnet  
Trioptic39  
UPCA *  
UPCE0 *  
UPCE1 *  
CANPOST  
IDTag  
Interleaved 2 of 5 * QR  
The Data Collection Wedge does not manage mutually exclusive option selections. The user is responsible for under-  
standing the options that can co-exist for the data collection device. The documentation provided from the manufac-  
turer of the scanner/imager being managed describes the interaction between symbologies and their configurations.  
Advanced Button (Hand Held Products Imager Only)  
The Advanced button is only available if a Hand Held Products Imager is in use. Because the Hand Held Products  
imager does not support configuration bar codes (available in the Integrated Scanner Programming Guide), the  
Advanced button function allows configuration parameters to be set for many of the HHP imager supported bar codes.  
If there are advanced configuration options for the selected Hand Held Products Imager symbology, an Advanced but-  
ton is displayed in the lower right corner of the panel. When the Enable check box is empty, the Advanced button is  
dimmed for a symbology with advanced configuration parameters. Not all bar code symbologies have configuration  
parameters so the Advanced button is not present for all symbologies.  
Sections that follow are the HHP symbologies with advanced configuration parameters that can be changed by the  
user.  
8 - 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Codabar - Advanced Properties  
Check Character  
Required – When enabled, the check character is required. Default is disabled.  
Transmit – When enabled, the check character is transmitted. Default is disabled.  
Start / Stop Character  
Transmit – When enabled, the start / stop characters are transmitted. Default is disabled.  
Code11 - Advanced Properties  
Check Digits Required – When enabled, only bar codes with two check digits are decoded. The default is dis-  
abled.  
8 - 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Code39 - Advanced Properties  
Check Character  
Required – When enabled, the check character is required. Default is disabled.  
Transmit – When enabled, the check character is transmitted. Default is disabled.  
Transmit Start / Stop Character – When enabled, the start / stop characters are transmitted. Default is disabled.  
Full ASCII – When enabled, full ASCII interpretation is used. Default is disabled.  
Append – When enabled, append and buffer codes that start with a space. Default is disabled.  
8 - 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EAN8 - Advanced Properties  
Transmit Check Character – When enabled, transmit the check character. Default is enabled.  
Addenda  
Read 2-Digit – When enabled, transmit the 2 digit addenda. Default is disabled.  
Read 5-Digit – When enable, transmit the 5 digit addenda. Default is disabled.  
Required – When enabled, only transmit bar codes with a 2 or 5 digit addenda. Default is disabled.  
Insert Separator – When enabled, insert a space between the code and addenda. Default is enabled.  
8 - 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EAN13 - Advanced Properties  
Transmit Check Character – When enabled, transmit the check character. Default is disabled.  
Addenda  
Read 2-Digit – When enabled, transmit the 2 digit addenda. Default is disabled.  
Read 5-Digit – When enable, transmit the 5 digit addenda. Default is disabled.  
Required – When enabled, only transmit bar codes with a 2 or 5 digit addenda. Default is disabled.  
Insert Separator – When enabled, insert a space between the code and addenda. Default is disabled.  
Note: A UPCA decoding algorithm will also decode EAN 13 labels. For correct operation, either disable the UPCA  
symbology when using EAN 13 labels or configure the UPCA settings to match the EAN 13 settings.  
8 - 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Interleaved 2 of 5 - Advanced Properties  
Check Character  
Required – When enabled, the check character is required. Default is disabled.  
Transmit – When enabled, the check character is transmitted. Default is disabled.  
8 - 20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mesa - Advanced Properties  
UPCA – When enabled, decode UPCA Mesa. Default is disabled.  
EAN13 – When enabled, decode EAN 13 Mesa. Default is disabled.  
Code39 – When enabled, decode Code 39 Mesa. Default is disabled.  
Code128 – When enabled, decode Code 128 Mesa. Default is disabled.  
Interleaved 2 of 5 – When enabled, decode Interleaved 2 of 5 Mesa. Default is disabled.  
Code93 – When enabled, decode Code 93 Mesa. Default is disabled.  
When Mesa is disabled on the Symbology panel (the Enable check box is cleared), tap the Advanced button and  
uncheck all parameters or sub-symbologies, on the Mesa Advanced Properties panel.  
Note: The root symbology (UPCA, EAN13, Code39, Code128, Interleaved 2 of 5 and/or Code 93) must be enabled  
before the matching enabled Mesa sub-symbology will decode.  
8 - 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MSI - Advanced Properties  
Transmit Check Character – When enabled, transmit the check character. Default is enabled.  
8 - 22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OCR Properties - Advanced  
Font – Font selection. Default is disabled.  
A = OCR A  
B = OCR B  
Money = OCR Money  
MICR = Magnetic Ink Character Recognition  
Direction – Decoder reads OCR fonts in any direction, but setting direction parameter correctly can increase  
decoding speed. Default is Left to Right.  
Template Template length must match the length of OCR string to be read. Default is dddddddd. Valid template  
selections are:  
a - alphanumeric character (digit or letter)  
c - check character  
d - digits from 0 to 9  
e - any character  
g - any character specified in group G  
h - any character specified in group H  
l - alphabetic letter  
r - delimits a row  
t - delimits multiple templates  
All characters are transmitted as is except for the selected template.  
Group G – Null terminated string defines the set of characters in group G. The default is null.  
Group H – Null terminated string defines the set of characters in group H. The default is null.  
Check – Enter the string constant 0123456789 for modulo10 checksums and the string constant 0123456789AB-  
CDEFGHIJKLMNOPQRSTUVWXYZ for modulo36 checksums.  
The default is null.  
OCR Template Examples  
1. To read a combination of 6 alpha and numeric characters use the following template:  
aaaaaa  
8 - 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. To read the same string with a modulo 10 check digit in the seventh character position, use the following tem-  
plate:  
aaaaaac  
Then enter 0123456789 for the Check parameter.  
3. To read either a string of 6 alphabetic letters OR a string of 8 numeric digits, use this template:  
lllllltdddddddd  
Note the use of the “t” to separate the first template from the second.  
4. To read multiple rows of OCR data as shown below:  
123456  
ABCDEF  
Either of the following templates could be used:  
ddddddrllllll or aaaaaaraaaaaa  
Note the use of the “r” to define the position of the second row.  
OCR Checksum Calculation  
The following explains how the checksum is generated for the OCR bar code:  
Modulo 10:  
1. Add the characters in the string (not including the checksum character). Valid values are 0 – 9 for modulo 10.  
2. Subtract 10 from the sum obtained above. Continue subtracting 10 until the remainder is less than 10.  
3. The remainder obtained above is the checksum. Enter this digit in the checksum position.  
Modulo 36:  
1. Add the characters in the string (not including the checksum character). Digit / Alpha values are defined as fol-  
lows for modulo 36: 0 – 9 = 0 – 9; A = 10, B = 11, … Z = 25  
2. Subtract 36 from the sum obtained above. Continue subtracting 36 until the remainder is less than 36.  
3. Subtract the remainder obtained above from 36. The value obtained is the checksum. Enter this character in  
the checksum position.  
8 - 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Planet - Advanced Properties  
Transmit Check Character – When enabled, transmit the check character. Default is enabled.  
Posicode - Advanced Properties  
Limited Labels – Select the type of Posicode Limited labels:  
None  
A – Posicode Limited A  
B – Posicode Limited B  
8 - 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Telepen - Advanced Properties  
Original Output – When enabled, output is Original Telepen. When disabled, output is AIM. Default is enabled.  
UPCA- Advanced Properties  
Transmit Check Character – When enabled, transmit the check character. Default is enabled  
Transmit Number System Digit – When enabled, transmit the number system digit. Default is enabled.  
Addenda  
Read 2-Digit – When enabled, transmit the 2 digit addenda. Default is disabled.  
Read 5-Digit – When enable, transmit the 5 digit addenda. Default is disabled.  
Required – When enabled, only transmit bar codes with a 2 or 5 digit addenda. Default is disabled.  
8 - 26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Insert Separator – When enabled, insert a space between the code and addenda. Default is enabled.  
Note: An EAN 13 decoding algorithm will also decode UPCA labels. For correct operation, either disable the EAN  
13 symbology when using UPCA labels or configure the EAN 13 settings to match the UPCA settings.  
UPCE0- Advanced Properties  
Note: The UPCE0 and UPCE1 parameters are always set to match each other. Therefore if a change is made to  
a parameter to either the EPCE0 or UPCE1 Advanced Properties that same change is automatically made  
to the Advanced Properties for the other symbology.  
Note: UPCE0 and UPCE1 are enabled as the same symbology at the scanner. Therefore, the only way for UPCE1  
configuration to be used is if UPCE0 is disabled. When UPCE0 is disabled, it is scanned by the imager but  
rejected by Data Collection Wedge.  
Transmit Check Character – When enabled, transmit the check character. Default is enabled.  
Transmit number System Digit – When enabled, transmit the number system digit. Default is enabled.  
Expand Version E – When enabled, expand version E to 12-digit UPCA format. Default is disabled.  
Addenda  
Read 2-Digit – When enabled, transmit the 2 digit addenda. Default is disabled.  
Read 5-Digit – When enable, transmit the 5 digit addenda. Default is disabled.  
Required – When enabled, only transmit bar codes with a 2 or 5 digit addenda. Default is enabled.  
Insert Separator – When enabled, insert a space between the code and addenda. Default is disabled.  
8 - 27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
UPCE1- Advanced Properties  
Note: The UPCE0 and UPCE1 parameters are always set to match each other. Therefore if a change is made to  
a parameter to either the EPCE0 or UPCE1 Advanced Properties that same change is automatically made  
to the Advanced Properties for the other symbology.  
Note: UPCE0 and UPCE1 are enabled as the same symbology at the scanner. Therefore, the only way for UPCE1  
configuration to be used is if UPCE0 is disabled. When UPCE0 is disabled, it is scanned by the imager but  
rejected by Data Collection Wedge.  
Transmit Check Character – When enabled, transmit the check character. Default is enabled  
Transmit number System Digit – When enabled, transmit the number system digit. Default is enabled.  
Expand Version E – When enabled, expand version E to 12-digit UPCA format. Default is disabled.  
Addenda  
Read 2-Digit – When enabled, transmit the 2 digit addenda. Default is disabled.  
Read 5-Digit – When enable, transmit the 5 digit addenda. Default is disabled.  
Required – When enabled, only transmit bar codes with a 2 or 5 digit addenda. Default is enabled.  
Insert Separator – When enabled, insert a space between the code and addenda. Default is disabled.  
8 - 28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HHP Properties  
When the MX7 Tecton is equipped with a Hand Held Products imager, this option is used to configure imager scanning  
parameters.  
Option  
Action  
Centering  
The centering feature is used to allow the user to accurately scan a selected bar code among a group  
of bar codes that are located closely together. When centering is turned on, the imager will only de-  
code bar codes that intersect the centering window defined by the user. The centering window must  
intersect the center of the bar code.  
The default centering settings define a 60 pixel square area in the center of the imager's field of view.  
The default is disabled. When enabled, the following parameters may be entered.  
Top: Valid:0 – 239, Default:120  
Bottom: Valid:240 – 479, Default:360  
Left: Valid:0 – 319, Default:188  
Right: Valid:320 – 639, Default:564  
Mode  
In Standard mode the imager will decode both linear and 2-D symbologies.  
In Aggressive Linear Decode mode the imager will only read linear symbologies in this mode, but de-  
coding these is faster and more accurate than Standard Mode.  
In Quick Omni mode the imager searches for a bar code in a reduced field located around the center  
of the image. Decoding is faster in this mode, but the user must center the aiming line over the bar  
code to be read. Both linear and 2-D symbologies can be read in this mode.  
The default is Standard.  
Range  
Set the linear range.  
Valid:1 – 6  
Default:3  
A value of 1 specifies that the linear range that is searched for a readable label is a tight vertical range  
near the aimer. A value of 6 specifies that the entire height of the image is to be searched.  
AIM  
Duration of the imager aim beam in 0.1 second increments.  
Valid:0 – 50 (0 to 5 seconds)  
Default:0  
Lights  
Specifies if the imager's lights and aimer should be left on during the entire decode process.  
The default is disabled.  
If disabled, the lights are turned on only during image capture, then turned off while the imager at-  
tempts to process and decode the bar code.  
If enabled, the aimer and lights remain turned on during the entire process.  
In Aggressive Linear Decode mode, set this parameter to enabled to improve the aimer visibility. See  
“Mode” above.  
8 - 29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Ctrl Char Mapping  
The Ctrl Char Mapping button on the Data Options tab activates a dialog to define the operations the Data Collection  
Wedge performs on control characters (values less than 0x20) embedded in bar codes. Control characters can be replaced  
with user-defined text which can include hat encoded or hex encoded values. In key message mode, control characters can  
also be translated to their control code equivalent key sequences.  
Translate All  
When Translate All is checked, unprintable ASCII characters (characters below 20H) in scanned bar codes are  
assigned to their appropriate CTRL code sequence when the bar codes are sent in Character mode.  
The wedge provides a one-to-one mapping of control characters to their equivalent control+character sequence of key-  
strokes. If control characters are translated, the translation is performed on the bar code data, prefix, and suffix before  
the keystrokes are simulated.  
Translate All  
This option is grayed unless the user has Key Message mode (on the Main tab) selected. In Key Message mode,  
when this option is enabled, control characters embedded in a scanned bar code are translated to their equivalent  
‘control’ key keystroke sequence (13 [0x0d] is translated to Control+M keystrokes as if the user pressed the CTRL,  
SHIFT, and m keys on the keypad). Additionally, when Translate All is disabled, any control code which has a key-  
stroke equivalent (enter, tab, escape, backspace, etc.) is output as a keystroke. Any control code without a key-  
stroke equivalent is dropped.  
Character  
This is a drop down combo box that contains the control character name. Refer to the Character drop down box for  
the list of control characters and their names. When a character name is selected from the drop down box, the  
default text Ignore (drop) is shown and highlighted in the Replacement edit control. Ignore (drop) is highlighted so  
the user can type a replacement if the control character is not being ignored. Once the user types any character  
into the Replacement edit control, reselecting the character from the Character drop down box redisplays the  
default Ignore (drop) in the Replacement edit control.  
Replacement  
The edit control where the user types the characters to be assigned as the replacement of the control character.  
Replacements for a control character are assigned by selecting the appropriate character from the Character drop  
down box, typing the replacement in the Replacement edit control (according to the formats defined above) and  
then selecting Assign. The assigned replacement is then added to the list box above the Assign button.  
For example, if ‘Carriage Return’ is replaced by Line Feed (by specifying ‘^J’ or ‘0x0A’) in the configuration, the  
8 - 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
value 0x0d received in any scanned bar code (or defined in the prefix or suffix) will be replaced with the value  
0x0a.  
The Wedge then sends Ctrl+J to the receiving application, rather than Ctrl+M.  
List Box  
The list box shows all user-defined control characters and their assigned replacements. All replacements are  
enclosed in single quotes to delimit white space that has been assigned.  
Delete  
This button is grayed unless an entry in the list box is highlighted. When an entry (or entries) is highlighted, and  
Delete is selected, the highlighted material is deleted from the list box.  
Custom Identifiers  
The Custom Identifiers button is located on the Data Options tab. Code IDs can be defined by the user. This allows pro-  
cessing parameters to be configured for bar codes that do not use the standard AIM or Symbol IDs or for bar codes that  
have data embedded at the beginning of the data that acts like a Code ID.  
These are called “custom” Code IDs and are included in the Symbology drop down box in the Symbology dialog, unless  
Enable Code ID is set to None. When the custom Code ID is found in a bar code, the configuration specified for the custom  
Code ID is applied to the bar code data. The dialog below allows the custom Code IDs to be configured.  
It is intended that custom code IDs are used to supplement the list of standard code IDs (if Enable Code ID is set to AIM or  
Symbol), or to replace the list of standard code IDs (if Enable Code ID is set to Custom).  
When Enable Code ID is set to None, custom code IDs are ignored.  
Note: Custom symbologies will appear at the end of the list in the Symbology dialog, and are processed at the beginning  
of the list in the scanner driver itself. This allows custom IDs based on actual code IDs to be processed before the  
code ID itself.  
Note: When Strip: Code ID is enabled, the entire custom Code ID string is stripped (i.e., treated as a Code ID).  
Note: After adding, changing and removing items from the Custom IDs list, tap the ok button to save changes and return to  
the Barcode panel.  
8 - 31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Name text box  
Name is the descriptor that is used to identify the custom Code ID. Names must be unique from each other; however,  
the Name and ID Code may have the same value. Name is used in the Symbology drop down box to identify the cus-  
tom Code ID in a user-friendly manner. Both Name and ID Code must be specified in order to add a custom Code ID to  
the Custom IDs list.  
ID Code text box  
ID Code defines the data at the beginning of a bar code that acts as an identifier (the actual Code ID). Both Name and  
ID Code must be specified in order to add a custom Code ID to the Custom IDs list.  
Custom ID Buttons  
Add  
Entering data into both the Name and ID Code fields enables the Add button. Tap the Add button and the data is  
added to the next empty location in the Custom ID list.  
Insert  
Tap on an empty line in the Custom ID list. The Add button changes to Insert. Enter data into both the Name and  
ID Code fields and tap the Insert button. The data is added to the selected line in the Custom IDs list.  
Edit  
Double tap on the item to edit. Its values are copied to the text boxes for editing. The Add button changes to  
Replace. When Replace is tapped, the values for the current item in the list are updated.  
Clear All  
When no item in the Custom IDs list is selected, tapping the Clear All button clears the Custom ID list and any text  
written (and not yet added or inserted) in the Name and ID Code text boxes.  
Remove  
The Clear All button changes to a Remove button when an item in the Custom IDs list is selected. Tap the desired  
line item and then tap the Remove button to delete it. Line items are Removed one at a time. Contents of the text  
box fields are cleared at the same time.  
8 - 32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Control Code Replacement Examples  
Example  
Control  
Character  
Configuration  
Translation  
data  
Example  
configuration  
Translated data  
Ignore(drop)  
The control character is discarded ESCape  
from the bar code data, prefix and  
suffix  
‘Ignore (drop)’  
0x1B in the bar code is  
discarded.  
Printable text  
Text is substituted for Control Char- Start of TeXt  
acter.  
‘STX’  
‘^M’  
0x02 in a bar code is con-  
verted to the text ‘STX’.  
Hat-encoded text The hat-encoded text is translated Carriage Re-  
Value 0x0d in a bar code  
is converted to the value  
0x0d.  
to the equivalent hex value.  
turn  
Escaped hat-en- The hat-encoding to pass thru to  
Horizontal Tab ‘\^I’  
Value 0x09 in a bar code  
is converted to the text  
‘^I’.  
coded text  
the application.  
Hex-encoded  
text  
The hex-encoded text is translated Carriage Re-  
‘0x0A’  
Value 0x0D in a bar code  
is converted to a value  
0x0A.  
to the equivalent hex value.  
turn  
Escaped hex-en- The hex-encoding to pass thru to  
coded text the application.  
Vertical Tab  
‘\0x0A’ or ‘0\x0A’ Value 0x0C is a bar code  
is converted to text ‘0x0A’  
Bar Code Processing Examples  
The following table shows examples of stripping and prefix/suffix configurations. The examples assume that the scanner is  
configured to transmit an AIM identifier.  
Symbology  
All  
EAN-128 (]C1)  
EAN-13 (]E0)  
Intrlv 2 of 5 (]IO)  
Code93  
Enable  
Enabled Enabled  
Enabled  
Enabled  
1
Disabled  
Min length  
Max length  
Strip Code ID  
Strip Leading  
Strip Bar Code Data  
Strip Trailing  
Prefix  
1
4
1
all  
all  
all  
10  
Enabled Enabled  
Disabled  
Enabled  
3
3
0
3
‘*123’  
0
‘1*’  
3
‘456’  
3
0
‘aaa’  
‘www’  
‘bbb’  
‘xxx’  
‘ccc’  
‘yyy’  
‘ddd’  
‘zzz’  
Suffix  
Provided that the wedge is configured with the above table, following are examples of scanned bar code data and results of  
these manipulations.  
Resulting Data  
Bar Code Symbology  
EAN-128  
Raw Scanner Data  
]C11234567890123  
]C111234567890123  
]C1123  
bbb1234567890xxx  
bbb11234567890xxx  
< rejected > (too short)  
ccc]E04567890yyy  
ccc]E0234567890yyy  
EAN-128  
EAN-128  
EAN-13  
]E01234567890987  
]E01231234567890987  
EAN-13  
8 - 33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
EAN-13  
I2/5  
]E01234  
ccc]E0yyy  
]I04444567890987654321  
]I04444567890123  
]I0444  
< rejected > (too long)  
ddd7890zzz  
I2/5  
I2/5  
dddzzz  
I2/5  
]I022245622  
]G0123456  
ddd45zzz  
Code-93  
Code-93  
Code-39  
Code-39 full ASCII  
Code-39  
< rejected > (disabled)  
< rejected > (disabled)  
aaa4567890www  
aaa1234567890www  
< rejected > (too short)  
]G0444444  
]A01234567890  
]A41231234567890  
]A4  
Rejected bar codes generate a bad scan beep. In some cases, the receipt of data from the scanner triggers a good scan  
beep (from the external scanner), and then the rejection of scanned bar code data by the processing causes a bad scan  
beep on the same data.  
8 - 34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Length Based Bar Code Stripping  
Use this procedure to create symbology rules for two bar codes with the same symbology but with different discrete  
lengths. This procedure is not applicable for bar codes with variable lengths (falling between a maximum value and a mini-  
mum value).  
Example 1:  
A normal AIM or Symbol symbology role can be created for the desired bar code ID.  
Next, a custom bar code symbology must be created using the same Code ID as the original AIM or Symbol ID rule and  
each rule would have unique length settings.  
Example 2:  
For the purposes of this example, the following sample bar code parameters will be used – EAN 128 and Code 128 bar  
codes. Some of the bar codes start with ‘00’ and some start with ‘01’. The bar codes are different lengths.  
34 character length with first two characters = “01” (strip first 2 and last 18)  
26 character length with first two characters = “01” (strip first 2 and last 10)  
24 character length with first two characters = “01” (strip first 2 and last 8). This 24 character bar code is Code 128.  
20 character length with first two characters = “00” (strip first 0 (no characters) and last 4)  
1. On the Data Options tab, set Enable Code ID to AIM.  
2. Create four custom IDs, using 1 for EAN 128 bar code and 0 for Code 128 bar code.  
c1 = Code = ‘]C1’  
c2 = Code = ‘]C1’  
c3 = Code = ‘]C0’ (24 character bar code is Code 128)  
c4 = Code = ‘]C1’  
3. AIM custom symbology setup is assigned in the following manner:  
c1 min length = 34, max length = 34, strip leading 2, strip trailing 18, Code ID enabled, Barcode Data = “01”  
c2 min length = 26, max length = 26, strip leading 2, strip trailing 10, Code ID enabled, Barcode Data = “01”  
c3 min length = 24, max length = 24, strip leading 2, strip trailing 8, Code ID enabled, Barcode Data = “01”  
c4 min length = 20, max length = 20, strip leading 0, strip trailing 4, Code ID enabled, Barcode Data = “00”  
4. Add the AIM custom symbologies. Refer to Symbology Settings for instruction.  
8 - 35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5. Tap the Barcode Data button.  
6. Tap the Add button.  
7. Add the data for the match codes.  
8. Refer to the previous section Bar Code Data Match List (page 8-12) for instruction.  
9. Scan a bar code and examine the result.  
8 - 36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Processing  
The Processing tab contains a user configurable key delay that applies to scanned bar codes as they are input when Remote  
Desktop is the application with the input focus.  
Setting  
Default  
Enable buffered key output  
Same buffer limit (characters)  
Delay between buffers  
Only in Remote Desktop  
Enabled and dimmed  
32  
75 ms  
Enabled  
Note: Settings on this panel have no effect when RFTerm is the application with the input focus.  
Enable buffered key output  
Enabled (checked) and dimmed. The user cannot change this setting.  
Same buffer limit  
Default is 32 ms. Raise or lower this value as desired.  
Delay between (key) buffers  
Specifies the number of milliseconds to delay after each character in the scanned bar code is processed as a keystroke.  
This value may need to be adjusted depending on the network traffic in the environment. The default value is 75 ms. Valid  
range is from 0 to 9999. A zero value is No Delay between characters.  
Enable only in Remote Desktop  
The delay specified in Wait between (key) buffers is applied only when Remote Desktop is enabled and is the application with  
the input focus. When disabled, all keystrokes are delayed by the number of milliseconds specified in Wait between (key) buf-  
fers.  
8 - 37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
About  
The About tab lists the version of the Data Collection Wedge (DCWedge) software and the type of laser scan (or imager) engine  
installed in the MX7 Tecton  
Valid scanner / imager types:  
HHP – Hand Held Products 5300 2D Imager  
Honeywell - 4313-TTL (N43XX)  
Honeywell - 7313-TTL (N73XX)  
Symbol – Symbol 955I  
Symbol - Symbol 955E  
Symbol – Symbol SE-1524ER  
No Scanner/None – No scanner installed  
8 - 38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Hat Encoding  
Hat Encoded Characters Hex 00 through AD  
8 - 39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Hat Encoded Characters Hex AE through FF  
8 - 40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
Enhanced Launch Utility  
Introduction  
The launch utility has two functions:  
Process registry based Launch items  
Process script based Launch items  
The registry based Launch items are processed before the script based Launch items.  
Registry Based Launch Items  
Registry based Launch items (documented here) are processed before the Script Based Launch items, see Script Based  
The Launch utility can use registry entries to auto-launch Windows CAB files. CAB files exist as separate files from the main  
installation image, and are copied to the device using ActiveSync, or using the optional SD card. The CAB files are copied into  
the folder System, which is the internal Flash drive. Then, information is added to the registry, if desired, to make the CAB file  
auto-launch at startup.  
The registry information needed is under the key  
HKEY_LOCAL_MACHINE\SOFTWARE\LXE\Persist  
The main subkey is any text, and is a description of the file. Then the values are added:  
Data  
Type  
Value  
Need  
Description  
FileName  
Installed  
Required String  
Required DWORD  
Required String  
Name of the CAB file, with full path (usually \System)  
Starts as 0, changed to 1 when the CAB file is installed  
FileCheck  
File name, with full path, of a file installed by the CAB file. If this file is not  
found, Launch assumes the CAB file is not installed or memory was lost.  
Order  
Optional  
Optional  
Optional  
DWORD  
DWORD  
DWORD  
Determines sequence of installation. Order=0 is installed first, order=99 is in-  
stalled last.  
Delay  
Delay, in seconds, after this item is installed and before the next one is in-  
stalled. If the install fails (or is not found) the delay does not occur.  
PCMCIA  
1=power up PCMCIA/CF slot after installation  
The auto-launch process is as follows.  
1. The launch utility opens the registry database and reads the list of CAB files to auto-launch.  
2. First it looks for FileName to see if the CAB file is present.  
If not, the registry entry is ignored.  
If it is present, and the Installed flag is not set, auto-launch makes a copy of the CAB file (since it gets deleted by  
installation) and runs the Microsoft utility WCELOAD to install it.  
3. If the Installed flag is set, auto-launch looks for the FileCheck file.  
If it is present, the CAB file is installed and that registry entry is complete.  
If the FileCheck file is not present, memory has been lost, and the utility calls WCELOAD to reinstall the CAB file.  
4. This process repeats for the next entry in the registry, until all registry entries are analyzed.  
Notes:  
To force execution every time, use a FileCheck of “dummy”, which is never found, forcing the item to execute. If an  
AUTOEXEC.BAT file is found, the terminal runs it by default.  
For persist keys specifying .EXE or .BAT files, the executing process is started, and then Launch continues, leaving the  
loading process to run independently.  
For other persist keys (including .CAB files), Launch waits for the loading process to complete before continuing. This is  
important, for example, to ensure that a CAB file is installed before the EXE files from the CAB file are run.  
9 - 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
The Order field is used to force a sequence of events; Order=0 is first, and Order=99 is last. Two items which have the same  
order are installed in the same pass, but not in a predictable sequence.  
The Delay field is used to add a delay after the item is loaded, before the next is loaded. The delay is given in seconds, and  
defaults to 0 if not specified. If the install fails (or the file to be installed is not found), the delay does not occur.  
The PCMCIA field is used to indicate that the file (usually a CAB file) being loaded is a radio driver, and the PCMCIA slots  
must be started after this file is loaded. By default, the PCMCIA slots are off on power up, to prevent the “Unidentified PCMCIA  
Slot” dialog from appearing. After the drivers are loaded, the slot can be turned on. The value in the PCMCIA field is a  
DWORD, representing the number of seconds to wait after installing the CAB file, but before activating the slot (a latency to  
allow the thread loading the driver to finish installation). The default value of 0 means the slot is not powered on. The default  
values for the default radio drivers (listed below) is 1, meaning one second elapses between the CAB file loading and the slot  
powering up.  
Note that the auto-launch process can also launch batch files (*.BAT), executable files (*.EXE), registry setting files (*.REG),  
or sound files (*.WAV). The mechanism is the same as listed above, but the appropriate OS application is called, depending  
on file type.  
9 - 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Launch Startup Options  
The Launch utility uses registry entries to enable or disable startup options. These flags are located in the registry key:  
HKEY_LOCAL_MACHINE\Software\LXE\Launch  
These can be configured using RegEdit. The options are as follows:  
Ship  
Default  
LTK  
Default  
Value  
Description  
LaunchPSM  
JumpStart  
1
0
Execute the Persist keys  
1
1
0
0
0
0
Look for and execute JumpStart scripts  
Execute any auto-install files in \System\Startup  
LaunchStart  
TimeService  
Launches the GrabTime utility as a service, so that the time and date are  
periodically automatically updated.  
It can often be useful to disable these as necessary, to troubleshoot system startup.  
Example:  
The following example loads and launches RFTerm.  
;; ------- RFTerm support  
[HKEY_LOCAL_MACHINE\SOFTWARE\LXE\Persist\LXE TE]  
"FileName"="\\System\\RFTERM.CAB"  
"Installed"=dword:0  
"FileCheck"="\\WINDOWS\\LXE\\RFTERM.EXE"  
"Order"=dword:11  
;; run the app after it has loaded and client device is ready  
[HKEY_LOCAL_MACHINE\SOFTWARE\LXE\Persist\RFTERM]  
"FileName"="\\WINDOWS\\LXE\\RFTERM.EXE"  
"Installed"=dword:0  
"FileCheck"="ALWAYSEXEC"  
"Order"=dword:40  
"Delay"=dword:1  
9 - 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Script Based Launch Items  
Note: Script Based Launch items (documented here) are processed after Registry Based Launch items, see Registry Based  
The Enhanced (script based) portion of the Launch utility provides several features:  
Launch .CAB file  
Run .EXE file  
Run .EXE file using specified parameters  
Run .BAT file  
Process .REG file  
Copy file, with or without overwriting of existing file  
Delete file  
Create directory  
Remove directory  
Add / Update a registry field  
Delete a registry field  
Add a registry subkey  
Delete a registry key  
Display an on-screen message; message requires OK to continue  
Conditional commands, based on existence of file or folder  
Conditional commands, based on device type  
End block of conditional commands  
Create a shortcut  
Perform a Suspend/Resume (Restart is not useful in this context).  
The script developer has the option of pausing script file execution until the current action completes, or continuing script file  
processing. The script developer is also able to pause for a specified number of milliseconds between commands.  
The utility also processes .REG files, using the same format as the legacy Launch Utility. It does this by calling the RegLoad util-  
ity. It can also process .BAT files, by calling the Command Prompt utility.  
By default, Enhanced Launch processes both registry entries and scripts, if present. There are registry settings to enable/  
disable processing of both types of files.  
Script files may have the extension .CLD (for cold boot) or .WRM (for warm boot.) With this extension, they may be clicked to  
execute from the File Explorer. When clicked directly, the extensions do not matter (a script ending in .CLD does not have to  
be preceded by a suspend/resume).  
Enhanced Launch Utility Use  
The Enhanced Launch Utility can be used at OS startup to execute commands from a script file or to launch programs. The  
user can configure scripts or registry entries for different operation after Warm Boot and Restart. Use of scripts and registry  
entries is documented in the following sections.  
File Names  
From a Restart, Launch tries to find the file JmpStart.cld, but from a Warm Boot it looks for JmpStart.wrm. The Launch pro-  
gram can also be run manually. Unless it is given a file as part of the command line it tries to run Launch.txt. The script file  
may be in ASCII or Unicode.  
When trying to find a script file, Launch looks in the following locations (in sequence):  
1. root directory of the Flash (\System\JmpStart.xxx)  
2. root directory of the SD card (\SD Card\JmpStart.xxx).  
In addition, a script file can be written (with a cld or .wrm extension), and can be double-clicked to run from the File  
Explorer.  
Command line structure  
Each command takes up one line. Every command uses the format:  
COMMAND,PARAMETER1,PARAMETER2,...etc.  
9 - 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Parameters are separated by a single comma. If a parameter requires a comma within it, the whole parameter must be  
enclosed in quote marks ("). Extra spaces are ignored between the comma and the next parameter.  
For Example  
To delete a file called Ive, got, commas, in, my, name.txt, use the command  
delete,"Ive, got, commas, in, my, name.txt".  
Enclosing quotes are used to allow commas inside a parameter, but are removed prior to executing the command. Thus,  
delete,deleteme.txt is the same as delete,“deleteme.txt”. If a parameter requires a quote mark within it, the whole parame-  
ter must first be enclosed within quote marks, and the required quote mark is represented by two quote marks (""). For  
example, to place the message This is how you display “quote markson the screen, use the command  
message,This is a heading,"This is how you display ""quote marks""".  
The case of a command is ignored, so delete is the same as DELETE and DeLeTe.  
Comments  
Any line that starts with a semicolon (;), a slash (‘/’) or an asterisk (*) is treated as a comment, and ignored by Launch.  
Launch also ignores any extra parameters (more than the required number) in a command. It is not recommended that  
comments be placed on the end of lines as any future changes could render your script files incompatible.  
Blank lines are also ignored.  
9 - 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Commands Supported by Launch  
ElseIfFile  
EndIf  
IfFile  
Mkdir  
Copy  
Delete  
IfTerm  
Rmdir  
EndIfFile  
EndIfTerm  
FCopy  
Launch  
LaunchCmd  
Message  
SetRegData  
SetRegKey  
Shortcut  
DelRegData  
DelRegKey  
ElseIf  
The commands supported by Launch are detailed below. Square brackets indicate that a parameter is optional. Characters  
in italics represent a variable, and not a literal.  
Copy  
Copies a file but does not overwrite an existing file.  
Description  
Copy,source-file,destination-file  
Syntax  
source-file: The file to be copied, including its path.  
destination-file: The destination path and filename.  
Parameters  
Example  
Notes  
copy,\Storage Card\MyData.dat,\Temp\MyData.dat  
If the destination file already exists, it is not overwritten, and no error is given.  
If the source file is blank, a zero-byte file is created.  
Delete  
Deletes the specified file.  
Description  
Syntax  
Delete,source-file  
source-file: The file to be deleted, including its path.  
Parameter  
Example  
delete,\Temp\MyData.dat  
DelRegData  
Description  
Syntax  
Deletes a specified registry data field.  
Delregdata,key,subkey,field  
key: The abbreviated major registry key where you want to delete a field. Can be one of:  
Parameter  
cr or hkcr (HKEY_CLASSES_ROOT)  
cu or hkcu (HKEY_CURRENT_USER)  
lm or hklm (HKEY_LOCAL_MACHINE).  
The case of key does not matter.  
subkey: The subkey that holds the field you want to delete.  
field: The field that you want to delete.  
Example  
Notes  
delregdata,LM,Software\WidgetsPlc\OurApp,AppName  
An error isn’t displayed if you specify a non-existent field, but is displayed if you specify a non-  
existent key or subkey.  
9 - 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
DelRegKey  
Description  
Syntax  
Deletes a specified registry subkey.  
Delregkey,key,subkey  
key: The abbreviated major registry key where you want to delete the subkey. Can be one of:  
Parameter  
cr or hkcr (HKEY_CLASSES_ROOT)  
cu or hkcu (HKEY_CURRENT_USER)  
lm or hklm (HKEY_LOCAL_MACHINE).  
The case of key does not matter.  
subkey: The subkey you want to delete.  
Example  
Notes  
delregkey,LM,Software\WidgetsPlc\OurApp  
Deletes the specified subkey and all of its contents (if any).  
ElseIf  
Description  
Begins conditional command block, executed only if the previous IF command was  
FALSE.  
ElseIf  
Syntax  
None  
Parameter  
Example  
Notes  
Results are unpredictable when ElseIf is not paired properly with If… command.  
ElseIfFile  
Begins conditional command block executed only if the file specified in the previous IfFile  
does not exist.  
Description  
ElseIfFile  
Syntax  
None  
Parameter  
Example  
Notes  
Results are unpredictable if not paired properly with IfFile command.  
9 - 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
EndIf  
Description  
Syntax  
Ends conditional command block begun with the previous IF command.  
EndIf  
None  
Parameter  
Example  
Notes  
Results are unpredictable if not paired properly with If... command.  
EndIfFile  
Description  
Syntax  
Ends conditional command block begun with the previous IF command.  
EndIfFile  
None  
Parameter  
Example  
Notes  
Results are unpredictable if not paired properly with IfFile command.  
EndIfTerm  
Ends conditional command block executed only if the device type specified in IfTerm match-  
es.  
Description  
EndIfTerm  
Syntax  
None  
Parameter  
Example  
Notes  
Results are unpredictable if not paired properly with IfTerm command.  
FCopy  
Copies a file, overwriting any existing file.  
Description  
Syntax  
fcopy,source-file,destination-file  
source-file: The file to be copied, including its path  
destination-file: The destination path and filename  
Parameters  
Example  
Notes  
fcopy,\Storage Card\MyData.dat,\Temp\MyData.dat  
If the destination file already exists it is overwritten.  
If the source file is blank, a zero-byte file is created.  
9 - 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
IfFile  
Begins the conditional execution of a block of commands only if the specified file exists.  
IfFile,file  
Description  
Syntax  
file: The path and filename to determine if the commands should be executed  
Parameter  
Example  
IfFile,\System\MyData.dat  
any number of commands, executed if file exists  
ElseIfFile  
any number of commands, executed if file does not exist  
EndIfFile  
If the file already exists the commands are executed.  
This test does not care if file is a file or directory.  
Nesting is supported.  
Notes  
IfTerm  
Begins the conditional execution of a block of commands only if the terminal matches the  
specified terminal type.  
Description  
IfTerm,terminal  
Syntax  
terminal: The terminal type to determine if the commands should be executed  
Parameter  
Example  
IfTerm,MX8  
any number of commands  
EndIfTerm  
If the terminal type is identical (not case-dependent) the commands are executed.  
Nesting with IfFile is supported. Nesting with IfTerm is meaningless.  
Notes  
Launch  
Description  
Syntax  
Runs a program.  
Launch,program,wait-code  
program: The full path and filename of the program to be run.  
Parameter  
wait-code: Tells Launch how to behave when the program is running.  
w(ait) causes Launch to stop processing the script until the program has finished executing.  
c(ontinue) makes Launch continue processing the script while the program is executing.  
Example  
Notes  
launch,\Windows\Calc.exe,w  
This differs from LaunchCmd in that Launch has no parameters.  
9 - 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
LaunchCmd  
Description  
Syntax  
Runs a program with arguments.  
Launchcmd,program,arguments,wait-code  
program: The full path and filename of the program to be run.  
arguments: The command line arguments for program.  
Parameters  
wait-code: Tells Launch how to behave when the program is running.  
w(ait) causes Launch to stop processing the script until the program has finished executing.  
c(ontinue) makes Launch continue processing the script while the program is executing.  
Example  
Notes  
launchcmd,\Windows\Pword.exe,\My documents\Doc1.doc,w  
This differs from Launch in that LaunchCmd allows parameters.  
Message  
Description  
Syntax  
Displays a message on the screen.  
Message,message-title,message-body  
message-title: A heading for the message. Can be left empty.  
message-body: The main body of the message. To display a message over multiple lines,  
use the \n character combination at the end of each line. To display a single backslash use  
two together (\\).  
Parameters  
Example  
Notes  
message,This is a message,”This is the first line,\nand this is the  
second”  
Displaying a message pauses the execution of the script file until the message is OK’d. This  
is displayed with a modal dialog.  
Mkdir  
Creates a directory.  
Description  
Syntax  
Mkdir,dir  
dir: The full path and name of the directory to be created.  
Parameters  
Example  
Notes  
mkdir,\Program Files\MyApp  
A new directory cannot be created if its parent directory doesn’t exist.  
For example, to create a directory called \MyApp with a subdirectory called SubDir1, use mk-  
dir,\MyApp followed by mkdir,\MyApp\SubDir1.  
9 - 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Rmdir  
Description  
Syntax  
Removes a directory.  
Rmdir,dir  
dir: The full path and name of the directory to be removed.  
Parameters  
Example  
Notes  
rmdir,\Program Files\MyApp  
A directory cannot be removed if it contains files or subdirectories.  
SetRegData  
Description  
Syntax  
Adds or updates a data field in the registry.  
Setregdata,key,subkey,type,field,data[,data2][,data3]...  
key: The abbreviated major registry key where you want to create/update the subkey. Can be  
one of:  
Parameter  
cr or hkcr (HKEY_CLASSES_ROOT)  
cu or hkcu (HKEY_CURRENT_USER)  
lm or hklm (HKEY_LOCAL_MACHINE).  
The case of key doesn’t matter  
subkey: The subkey you want to create/update a field in.  
type: The data type of the field you wish to create/update. Can be s (for string value), dd (for  
decimal value), dx (for hexadecimal value) or b (for binary value). The case of type doesn’t  
matter. If you’re altering an existing field, type can be different from the current type.  
field: The name of the new field to be created/updated.  
data: The value of the field being created. This depends on the type of field. Binary fields can  
have many values (up to 2000 bytes). In this case the data field holds the number of bytes in  
the binary field, and each byte is given as a subsequent parameter in hexadecimal (data2,  
data3 etc.).  
Example  
Setregdata,LM,WidgetsPlc\Info,s,AppName,The Widget Program  
Setregdata,LM,WidgetsPlc\Info,dx,HexField,FA5B  
Setregdata,LM,WidgetsPlc\Info,b,5,d3,62,58,f1,9c  
9 - 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
SetRegKey  
Description  
Syntax  
Adds a sub key to the registry.  
Setregkey,key,subkey  
key: The abbreviated major registry key where you want to create the subkey. Can be one of:  
Parameters  
cr or hkcr (HKEY_CLASSES_ROOT)  
cu or hkcu (HKEY_CURRENT_USER)  
lm or hklm (HKEY_LOCAL_MACHINE).  
The case of key doesn’t matter.  
subkey: The subkey you want to create.  
Example  
Notes  
Setregkey,LM,Software\MyApp  
Attempting to create a key that already exists does not cause an error.  
Shortcut  
Description  
Syntax  
Creates a shortcut.  
Shortcut,name,target  
name: The path and name of the shortcut file. The file name must end in .lnk for Windows to  
recognize it as a shortcut.  
target: The target of the shortcut. If the target has a space in it quote marks must be used  
(see Command Line Structure section and example below).  
Parameters  
Example  
Notes  
shortcut,\Program Files\Widget.lnk,"""\My App\Widget.exe"""  
No validation is performed on target to be sure it is executable.  
9 - 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Launch Error Messages  
Launch displays a message if it encounters an error during the processing of a script. It is possible to get cascading error mes-  
sages, as Launch does not stop processing the script if it encounters an error. An example of this would be a failure creating a  
directory causing the failure of all files copied to that directory.  
Here is a list of the possible error messages that could be given:  
Error Message  
Given by  
Description  
Bad wait code wait-code  
Launch  
LaunchCmd  
The wait-code wasn’t recognized  
Directory Creation Failed error-  
code  
MkDir  
RmDir  
-
There was a problem encountered creating the directory  
There was a problem encountered removing the directory  
Directory Removal Failed error-  
code  
Error reading script file  
An error occurred reading the script file.  
File Copy Failed error-code  
Copy  
Fcopy  
There was a problem encountered copying the file  
File Delete Failed error-code  
Invalid Command: command  
Invalid Data Length data  
Invalid Data Type type  
Delete  
There was a problem encountered deleting the file  
The command wasn’t recognized  
-
SetRegData  
SetRegData  
SetRegData  
SetRegData  
Tried to set more than 2000 byte values in a binary field  
The value of the type parameter is invalid  
Invalid decimal data data  
Invalid hex data data  
The data field doesn’t contain decimal data  
The data field doesn’t contain hexadecimal data  
The key parameter to the command has not been recognized  
Invalid Registry Key key  
DelRegData  
DelRegKey  
SetRegData  
DelRegKey  
Parms: Invalid Create Directory  
MkDir  
Not enough parameters were supplied.  
Not enough parameters were supplied.  
Not enough parameters were supplied.  
Not enough parameters were supplied.  
Parms: Invalid Create Registry Key SetRegKey  
Parms: Invalid Create Shortcut  
Shortcut  
Parms: Invalid Delete Registry  
Data  
DelRegData  
Parms: Invalid Delete Registry Key DelRegKey  
Not enough parameters were supplied.  
Not enough parameters were supplied.  
Parms: Invalid File Copy  
Copy  
Fcopy  
Parms: Invalid File Delete  
Delete  
Not enough parameters were supplied.  
Not enough parameters were supplied.  
Parms: Invalid Program Name  
Launch  
LaunchCmd  
Parms: Invalid Remove Directory RmDir  
Not enough parameters were supplied.  
Parms: Invalid Set Registry Data  
Parms: Invalid User Message  
SetRegData  
Message  
Not enough parameters were supplied.  
Not enough parameters were supplied.  
Program Launch couldn't get Exit- Launch  
There was a problem getting the exit status of the program.  
Code error-code  
LaunchCmd  
Program Launch Failed error-code Launch  
There was a problem executing the program.  
LaunchCmd  
Registry Key Create Failed error- SetRegKey  
code  
There was a problem creating the registry key given.  
There was a problem deleting the registry key given.  
Registry Key Delete Failed error- DelRegKey  
code  
9 - 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Error Message  
Given by  
Description  
Registry Value Delete Failed error- DelRegData  
code  
There was a problem deleting the registry data. Most likely a bad sub-  
key.  
Registry Value Set Failed error-  
code  
SetRegData  
There was a problem setting the registry data. Most likely a bad subkey.  
Shortcut Creation Failed error-  
code  
Shortcut  
-
There was a problem encountered creating the shortcut.  
Unable to open file script-file  
There was a problem opening the script-file. This message is only dis-  
played when manually running Launch.  
Example Script File  
iffile,\System\applock.cab  
launchcmd,\Windows\wceload.exe,"/noaskdest /noui \System\applock.cab",w  
launch,\Windows\applockprep.exe,c  
endiffile  
launchcmd,\Windows\wceload.exe,"/noaskdest /noui \System\wedge.cab",w  
iffile,\System\summit.cab  
launchcmd,\Windows\wceload.exe,"/noaskdest /noui \System\summit.cab",w  
endiffile  
iffile,\System\RFTerm.cab  
launchcmd,\Windows\wceload.exe,"/noaskdest /noui \System\RFTerm.cab",w  
endiffile  
iffile,\System\Java.cab  
launchcmd,\Windows\wceload.exe,"/noaskdest /noui \System\Java.cab",w  
launchcmd,\Windows\wceload.exe,"/noaskdest /noui \Windows\Jeode.cab",w  
endiffile  
launch,\System\regrest.exe,w  
coldboot  
9 - 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
10  
Enabler Installation and Configuration  
Introduction  
This section discusses Honeywell supported features of Wavelink Avalanche Mobile Device Servers. This section is split into  
three basic areas:  
Installation  
User Interface  
Enabler Configuration  
Installation  
To use the Wavelink Avalanche MC System, the following items are required:  
A desktop or laptop PC on which to install the Avalanche MC Console.  
A desktop or laptop PC on which to install the Avalanche Mobile Device Server (this can be the same PC where the Avalanche  
MC Console is installed).  
Wavelink Avalanche MC Console 4.2 or later.  
A Wavelink Device License for each client device.  
To use Avalanche Remote Control, the following additional items are required:  
Wavelink Remote Control plug-in, 2.0 or later  
A Wavelink Remote Control License for each client device  
Installing the Enabler on Mobile Devices  
The Enabler for a MX7 Tecton (with a Windows Mobile operating system) can update the operating system if the MX7 Tecton  
has a storage card. The presence of a storage card is one of the package selection criteria.  
Mobile devices have the Avalanche Enabler installation files loaded, but not installed, on the mobile device when it is shipped.  
The installation files are located in the \System folder.  
Note: Important: If the user is NOT using Wavelink Avalanche to manage their mobile device(s), the Enabler should not be  
installed on the mobile device(s). Doing so results in unnecessary delays when booting the device.  
The Avalanche Enabler installation file HSM_ENABLER_CAB is loaded on the MX7 Tecton by Honeywell; however, the device  
is not configured to launch the Enabler installation file automatically. The installation application must be run manually the first  
time Avalanche is used.  
After the installation application is manually run, the Enabler will, by default, be an auto-launch application.  
This behavior can be modified by accessing the Avalanche Update Settings panel through the Enabler Interface.  
The RMU.CE.CAB file is placed on the device during manufacturing in the \System\RMU folder.  
During the Enabler installation process, the Enabler checks for the RMU.CE.CAB file in the \System folder.  
If present, it assumes the RMU.CE.CAB file is already installed and continues.  
If the file RMU.CE.CAB file is not present, it looks for the file in the \System\RMU folder.  
If present, the Enabler copies the file to the \System folder and installs it.  
At this point, the OS will automatically install the RMU (Remote Management Utility) after the MX7 Tecton reboots.  
10 - 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Enabler Uninstall Process  
To remove the Avalanche Enabler from the MX7 Tecton:  
Delete the Avalanche folder located in the \System directory.  
Warm boot the MX7 Tecton.  
The Avalanche folder cannot be deleted while the Enabler is running. See Stop the Enabler Service.  
If sharing errors occur while attempting to delete the Avalanche folder, warm boot the MX7 Tecton, immediately delete the Ava-  
lanche folder, and then perform another warm boot.  
Stop the Enabler Service  
To stop the Enabler from monitoring for updates from the Mobility Center Console:  
1. Open the Enabler Settings Panels by tapping the Enabler icon on the MX7 Tecton desktop.  
2. Select File > Settings.  
3. Select the Preferences tab.  
4. Select Do not monitor to prevent automatic monitoring upon Startup.  
5. Select Exit Application for an immediate shutdown of all Enabler update functionality upon exiting the user interface.  
6. Tap the OK button to save the changes.  
7. Reboot the MX7 Tecton if necessary.  
Update Monitoring Overview  
There are three methods by which the Enabler on the MX7 Tecton can communicate with the Mobile Device Server running on  
the host machine.  
Wired via a serial cable between the Mobile Device Server PC and the MX7 Tecton.  
Wired via a USB connection, using ActiveSync, between the Mobile Device Server PC and the MX7 Tecton.  
Wirelessly via the MX7 Tecton radio and an access point  
After installing the Enabler on the MX7 Tecton the Enabler searches for a Mobile Device Server, first by polling all available  
serial ports and then over the wireless network.  
The Enabler running on the MX7 Tecton will attempt to access COM1, COM2, and COM3. “Agent not found” will be reported if  
the Mobile Device Server is not located or a serial port is not present or available (COM port settings can be verified using bar  
code wedge panels on the MX7 Tecton).  
The wireless connection is made using the default wireless [radio] interface on the mobile device therefore the MX7 Tecton must  
be actively communicating with the network for this method to succeed.  
If a Mobile Device Server is found, the Enabler automatically attempts to apply all wireless and network settings from the active  
profile. The Enabler also automatically downloads and processes all available packages.  
If the Enabler does not automatically detect the Mobile Device Server, the IP address of the Mobile Device Server can be  
entered on the Connect tab of the Enabler setup. See Enabler Configuration (page 10-4) for details.  
Mobile Device Wireless and Network Settings  
Once the connection to the Mobile Device Server is established, the MX7 Tecton Enabler attempts to apply all network and wire-  
less settings contained in the active profile.  
The success of the application of settings is dependent upon the local configuration of control parameters for the Enabler.  
These local parameters cannot be overridden from the Avalanche MC Console.  
The default Enabler adapter control settings are:  
Manage network settings – enabled  
Use Avalanche network profile – enabled  
Manage wireless settings – disabled for Windows CE devices  
10 - 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
To configure the Avalanche Enabler management of the network and wireless settings:  
1. Open the Enabler Settings Panels by tapping the Enabler icon on the desktop.  
2. Select File > Settings.  
3. Select the Adapters tab.  
4. Choose settings for the Use Manual Settings parameter.  
5. Choose settings for Manage Network Settings, Manage Wireless Settings and Use Avalanche Network Profile.  
6. Tap the OK button to save the changes.  
7. Reboot the device.  
Preparing a Device for Remote Management  
Two additional utilities are necessary for remote management.  
Remote Management Utility (RMU)  
The Remote Management Utility (RMU) must be installed on all mobile devices first – then you can control mobile device  
reboot, storage RAM adjustment, real-time updates and Avalanche Enabler properties.  
If in doubt, verify RMU.CE.CAB exists in the \System folder. If the RMU.CE.CAB file is present when the Enabler is  
installed, the RMU is also installed.  
Important: If the OS package includes double-byte Asian fonts, the storage RAM property of the RMU must be higher than  
the default value (40MB).  
If the amount of storage RAM is too low, the Enabler returns a “Mobile unit out of resources” error.  
To determine the minimum value required, inspect the RMU.StorageRAM>=nn parameter in the Criteria field for the OS  
package. Generally, this setting should be approximately 40 MB above the amount of RAM in use on the device for a stan-  
dard OS and 50MB above the amount of RAM in use for an OS with Asian fonts.  
For example, if after installing all the software, the device shows 5MB in use, this setting should be about 45MB for a stan-  
dard OS, 55 MB for an Asian font OS.  
Wireless Configuration Application (WCA)  
Use the Wireless Configuration Application (WCA) when you want to remotely manage the Summit client device. This utility  
is downloaded and installed in addition to the Remote Management Utility. The WCA is included when the Summit radio  
driver software is updated. The WCA is automatically installed when the radio driver is updated.  
10 - 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
User Interface  
The Enabler can be configured and controlled manually through the user interface on the MX7 Tecton. This section details the  
functionality that can be controlled by the user or system administrator.  
Screen displays shown in this section are designed to present the end-user with information graphically.  
Information on the screen displays may be split between one or many tabbed panels.  
Standard Avalanche Enabler parameters that are not supported may be missing or dimmed (visible but unable to be edited) on  
the tabbed panels or screen displays.  
Enabler Configuration  
Depending on the version of the Enabler running on the MX7 Tecton, the desktop Enabler icon may look like one of the fol-  
lowing:  
Enabler Settings Icon  
or  
The Enabler user interface application is launched by tapping either the Enabler Settings icon on the desktop or Taskbar or  
by selecting Avalanche Enabler from the Programs menu.  
The opening screen presents the MX7 Tecton user with the connection status and a navigation menu.  
Note: Some parameters and features described in this section may not be available if you do not have the latest version of  
the Enabler. Contact Technical Assistance (page 16-1) for upgrades.  
10 - 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
File Menu Options  
Connect  
The Connect option under the File menu allows the user to initiate a manual connection to the Mobile Device Server.  
The connection methods, by default, are wireless and COM connections. Any updates available will be applied to the  
MX7 Tecton immediately upon a successful connection.  
Scan Config  
The Scan Configuration feature is not supported. The Scan Config option under the File menu allows the user to con-  
figure Enabler settings using a special bar code that can be created using the Avalanche MC Console utilities. Refer to  
the Wavelink Avalanche Mobility Center User Guide for details.  
Settings  
The Settings option under the File menu allows the MX7 Tecton user to access the control panel to locally configure  
the Enabler settings. The Enabler control panel is, by default, password protected.  
The default Settings password is system. The password is not case-sensitive.  
10 - 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Avalanche Update using File > Settings  
Use these menu options to setup the Avalanche Enabler on the MX7 Tecton. Change settings and save the changes  
(reboot) before connecting to the network.  
Alternatively, the Mobile Device Server can be disabled until needed (refer to the Wavelink Avalanche Mobility Center  
User’s Guide for details).  
Menu Options  
Note: Your MX7 Tecton screen display may not be exactly as shown in the following menu options. Contact Technical  
Assistance (page 16-1) for version information and upgrade availability.  
Option  
Function  
Connection  
Enter the IP Address or host name of the Mobile Device Server. Set the order in which  
serial ports or RF connections are used to check for the presence of the Mobile Device  
Server.  
Execution  
Not available in this release. Use AppLock (Application Locking) (page 6-1), which is  
resident on each device.  
Server Contact  
Setup synchronization, scheduled Mobile Device Server contact, suspend and reboot  
settings.  
Data  
Control when data is transferred between the device and the Mobile Device Server.  
Set options for Enabler startup or shutdown and logging.  
Set options for Taskbar.  
Preferences  
Taskbar  
Scan Config  
This option allows the user to configure Enabler settings using a special bar code that  
is created by the Avalanche MC Console. Scan Config not currently supported.  
Display  
Set up the Windows display at startup, on connect and during normal mode. The set-  
tings can be adjusted by the user.  
Shortcuts  
SaaS  
Add, delete and update shortcuts to user-allowable applications.  
Configure the Enabler to connect with Avalanche on Demand.  
Adapters  
Enable or disable network and wireless settings. Select an adapter and switch between  
the Avalanche Network Profile and manual settings.  
Status  
View the current adapter signal strength and quality, IP address, MAC address, SSID,  
BSSID and Link speed. The user cannot edit this information.  
10 - 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Connection  
Setting  
Function  
Avalanche Server Address  
Enter the IP Address or host name of the Mobile Device Server assigned to the  
MX7 Tecton.  
Check Serial Connection  
Indicates whether the Enabler should first check for serial port connection to the  
Mobile Device Server before checking for a wireless connection to the Mobile De-  
vice Server.  
Disable ActiveSync  
Disable ActiveSync connection with the Mobile Device Server.  
Default is disabled. Minimum Link Speed dimmed.  
Restrict Adapter Link Speed  
10 - 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Execution  
Note the dimmed options on this MX7 Tecton panel. This menu option is designed to manage downloaded applications  
for automatic execution upon startup.  
Setting  
Function  
Auto-Execute Selection  
An application that has been installed with the Avalanche Management system can  
be run automatically following each boot.  
Select Auto-Execute App  
Delay before execution  
The drop-down box provides a list of applications that have been installed with the Av-  
alanche Management System.  
Time delay before launching Auto-Execute application.  
10 - 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Server Contact  
Note: Your MX7 Tecton screen display may not be exactly as shown above. Contact Technical Assistance (page 16-  
1) for upgrade availability and version information.  
Setting  
Function  
Sync Clock  
Reset the time on the MX7 Tecton based on the time on the Mobile Device Server  
host PC.  
Contact  
On Startup – Connect to the Mobile Device Server when the Enabler is accessed.  
On Resume – Connect to the Mobile Device Server when resuming from Suspend  
mode.  
On IP Change – Connect to the Mobile Device Server when the IP address of the  
MX7 Tecton changes.  
On Ext. Power – Initiate connection to the Mobile Device Server when the device  
is connected to an external power source, such as based on a docking event.  
Periodic Update  
Allows the administrator to configure the Enabler to contact the Mobile Device  
Server and query for updates at a regular interval beginning at a specific time.  
Wakeup device if suspended  
If the time interval for periodic contact with the Mobile Device Server occurs, a mo-  
bile device that is in Suspend Mode can wakeup and process updates.  
Reboot before attempt  
Require external power  
Use relative offset  
Reboot mobile device before attempting to contact Mobile Device Server.  
Only connect when the mobile device has external power.  
Dimmed.  
10 - 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Data  
The Data tab controls when data is transferred between the MX7 Tecton and the Mobile Device Server.  
Setting  
Function  
Transfer Data When Device is Idle  
When enabled, periodic updates from the Mobile Device Server are post-  
poned until the MX7 Tecton has been idle for the specified period of time. The  
default is disabled.  
Idle timeout  
Specify the length of time the device must be idle before a periodic update  
can run, used when the parameter above is enabled.  
Real-time Statistics  
Report  
When checked, the statistics are transmitted over the network by the En-  
abler.  
Specifies the Report Interval, how frequently the Enabler reports statistics to  
the Mobile Device Server.  
Retransmit After Server Contact  
Specifies if the device sends statistics to the Mobile Device Server immedi-  
ately following a connection to the server.  
10 - 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Preferences  
For best results, use AppLock to manage the taskbar. AppLock (Application Locking) (page 6-1) is resident on each  
mobile device.  
Administration  
By default, Keep settings unlocked for 10 minutes is disabled (check box is blank).  
Application  
Setting  
Function  
Startup  
Behavior of the Enabler when the MX7 Tecton boots up. The default is Monitor for Updates.  
Do not Monitor - When the device boots, do not launch the Enabler application and do not attempt to  
connect to the Mobile Device Server.  
Monitor for Updates - Attempt to connect to the Mobile Device Server and process any updates that are  
available. Do not launch the Enabler application.  
Launch User Interface - Attempt to connect to the Mobile Device Server and process any updates that  
are available. Launch the Enabler application.  
Shutdown Behavior of the monitor when the Enabler is exited. The default is Monitor for Updates.  
Monitor for Updates - Attempt to connect to the Mobile Device Server and process any updates that are  
available. Do not launch the Enabler application.  
Exit Application - Terminates the monitor (requires successful password entry if a password has been  
configured).  
10 - 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Activity Log  
Setting  
Function  
Log Level  
Use this option to control the level of detail recorded in the log file. The default is No Activity Log.  
No Activity Log - No log file is written.  
Critical - Only critical errors written to the log files.  
Error - Communication or configuration problems are written to the log file along with critical  
messages.  
Warning - Possible operation problems are written to the log file along with critical and error  
messages.  
Info - Operational information is written to the log file.  
Debug - The most detailed log file.  
Display Level Use this option to control the level of detail shown on the main Enabler screen. The default is Basic  
Output.  
Basic Output - General information is displayed.  
Critical - Critical errors are displayed in addition to those above.  
Error - Communication or configuration problems are displayed in addition to those above.  
Warning - Possible operation problems are displayed in addition to those above.  
Info - Operational information is displayed in addition to those above.  
Debug - The most detailed list is displayed..  
10 - 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Taskbar  
For best results, use AppLock to manage the taskbar. AppLock (Application Locking) (page 6-1) is resident on each  
mobile device.  
The Display State options control the appearance of the taskbar while using the Enabler interface.  
Normal - taskbar is visible, taskbar icons function normally.  
Hidden - taskbar is not displayed  
Locked - taskbar is visible, but most icons are hidden or for information only.  
Scan Config  
For best results, use eXpress Config and eXpress Scan for this function. eXpress Scan is included with the updated  
MX7 Tecton enablers.  
10 - 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Scan Config functionality is a standard option of the Wavelink Avalanche MC system but is not currently supported on  
the MX7 Tecton.  
10 - 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Display  
The user interface for the Enabler can be configured to dynamically change based on the status of the MX7 Tecton  
connection with the Mobile Device Server.  
Setting  
At startup  
On connect  
Normal  
Function  
Default is Half Screen. Options are Half screen, Hidden or Full screen.  
Default is As Is. Options are As is, Half screen, or Full screen.  
Default is As Is. Options are Half screen, Hidden or As Is.  
10 - 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Shortcuts  
For best results, use AppLock for this function. AppLock (Application Locking) (page 6-1) is resident on each mobile  
device.  
Configure shortcuts to other applications on the MX7 Tecton. Shortcuts are viewed and activated in the Programs  
panel. This limits the user’s access to certain applications when the Enabler is controlling the mobile device display.  
10 - 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SaaS  
Use to configure the Enabler to connect with Avalanche on Demand. This is a Software-as-a-Service version of Ava-  
lanche. Using either of the SaaS configuration options below assumes the user has registered with Wavelink.  
Setting  
Function  
Disable SaaS  
Scan Configure SaaS  
No SaaS connection is used.  
Scan bar codes printed from within the Avalanche Console to configure the Enabler  
for the SaaS connection.  
Manually Configure SaaS  
Manually enter the SaaS connection information. Enter the server address on the  
Connection tab and the customer ID in the Company text box.  
10 - 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Adapters  
Note: Review the MX7 Tecton network settings configuration utilities and the default values before setting All Adapters  
to Enable in the Adapters applet..  
Setting  
Function  
Manage Network Settings  
When enabled, the Enabler will control the network settings. This parameter cannot  
be configured from the Avalanche Mobility Center Console and is enabled by default.  
Manage Wireless Settings  
When enabled, the Enabler will control the wireless settings. This parameter cannot  
be configured from the Avalanche Mobility Center Console and is disabled by default.  
For Summit clients, Manage Wireless Settings should not be checked because con-  
figuration packages provide more radio configuration options.  
Current Adapter  
Primary Adapter  
Lists all network adapters currently installed on the MX7 Tecton.  
Indicates if the Enabler is to attempt to configure the primary adapter (active only if  
there are multiple network adapters).  
Icon on taskbar  
Places the Avalanche icon in the Avalanche taskbar that may, optionally, override the  
standard Windows taskbar.  
Use Avalanche Network Profile The Enabler will apply all network settings sent to it by the Mobile Device Server.  
Avalanche Icon (varies by En- Selecting the Avalanche Icon will access the Avalanche Network Profile tab which  
abler version)  
will display current network settings.  
or  
Use Manual Settings  
When enabled, the Enabler will ignore any network or wireless settings coming from  
the Avalanche MC Console and use only the network settings on the MX7 Tecton.  
Properties Icon  
Selecting the Properties icon displays the Manual Settings Properties dialog applet.  
From here, the user can configure Network, DNS, Authentication and Wireless pa-  
rameters using the displays shown below. Note the authentication tab may not be  
present in all versions of the Enabler.  
Note: A reboot may be required after enabling or disabling these options.  
10 - 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Manual Settings Properties  
Do not enable “Manage Wireless Settings” for Summit Client devices.  
Note: When you download a profile that is configured to manage network and wireless settings, the Enabler will not  
apply the manage network and wireless settings to the adapter unless the global Manage wireless settings and  
Manage network settings options are enabled on the Adapters panel. Until these options are enabled, the  
network and wireless settings are controlled by the third-party software associated with these settings.  
10 - 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Status  
The Status panel displays the current status of the MX7 Tecton network adapter selected in the drop down box. Note  
the availability of the Windows standard Refresh button.  
When the Windows Refresh button is tapped, the signal strength, signal quality and link speed are refreshed for the  
currently selected adapter. It also searches for new adapters and may cause a slight delay to refresh the contents of  
the drop-down menu.  
Link speed indicates the speed at which the signal is being sent from the adapter to the MX7 Tecton. Speed is depen-  
dent on signal strength.  
10 - 20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Exit  
The Exit option is password protected. The default password is leave. The password is not case-sensitive.  
Depending on the behavior chosen for the Shutdown setting the following screen may be displayed:  
Note: The icon on the screen above may differ based on the version of the Enabler installed on the MX7 Tecton.  
Change the option if desired. Tap the X button to cancel Exit. Tap the OK button to exit the Avalanche applet.  
10 - 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Using Remote Management  
1. Configure the radio to connect to the network running the Mobile Device Server. After the MX7 Tecton is connected, proceed  
to step 2.  
2. If it is desired to configure the radio using the Summit package, add the configured package to the Wavelink Avalanche MC  
Console and enable it.  
3. Verify RMU.CE.CAB exists in the \System\RMU folder.  
4. Double tap the MX7 Tecton enabler CAB file in the \System folder.  
5. The enabler automatically launches after installation and contacts the Mobile Device Server. The Avalanche MC Console  
connected to that Mobile Device Server identifies the remote device and performs a sync. This downloads any available  
packages available for the MX7 Tecton.  
Using eXpress Scan  
eXpress Scan Desktop Icon  
If the MX7 Tecton has an eXpress Scan icon on the desktop, eXpress Scan may be used for the initial configuration of the  
device.  
If the eXpress Scan icon is not present on the desktop, install the Enabler. If the icon is still not present, Enabler must be  
updated.  
If the eXpress Scan icon is present, follow these steps to configure the MX7 Tecton to connect with the wireless network and the  
Mobile Device Server.  
Creating Bar Codes  
Bar codes are created with the eXpress Config utility on the desktop/laptop computer, not the mobile device. Depending on  
the bar code length and the number of parameters selected, eXpress Config generates one or more bar codes for device  
configuration. The bar codes contain configuration parameters for the wireless client and may also specify the address of  
the Mobile Device Server.  
Bar codes should be printed at a minimum of 600 dpi.  
Scanning Bar Codes  
Folow these instructions for each device to be configured.  
1. Start eXpress Scan on the MX7 Tecton by double tappng the eXpress Scan icon.  
2. Enter the bar code passcode, if any.  
3. Tap Start.  
4. Bar Code 1 must be scanned first. The scanned data is displayed in the “Data” text box. The password, if any, entered  
above is compared to the password entered when the bar codes were created.  
10 - 22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
5. If the passwords match, the bar code data is processed and the screen is updated to reflect the number of bar codes  
included in the set.  
6. If the passwords do not match, an error message is displayed. The current screen can be closed using the X box in the  
upper right corner. The password can be re-entered and Bar Code 1 scanned again.  
7. The remaining bar codes may be scanned in any order. After a bar code is scanned, the bar code is removed from the  
“Remaining:” list and placed in the “Scanned:” list.  
Process Complete  
After the last bar code is scanned, the settings are automatically applied.  
Once configured, the MX7 Tecton is warmbooted. After it reconnects to the wireless network and the Mobile Device Server,  
any software updates and additional configuration data are downloaded.  
10 - 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
10 - 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
Wireless Network Configuration  
Introduction  
The Summit client device is a Summit 802.11a/b/g radio, capable of 802.11a, 802.11b and 802.11g data rates. The radio can be  
configured for no encryption, WEP encryption or WPA security.  
Security options supported are:  
Important Notes  
It is important that all dates are correct on the MX7 Tecton and host computers when using any type of certificate. Cer-  
tificates are date sensitive and when the date is not correct authentication will fail.  
!
!
It may be necessary to upgrade radio software in order to use certain Summit Client Utility (SCU) features. Contact  
When using the 802.11a radio, the U-NII 1 band is the preferred band for indoor operation. For regulatory domains in  
which the U-NII 3 band is allowed, the following channels are supported: 149, 153, 157 and 161. The AP must be con-  
figured accordingly.  
!
After making any changes to the wireless configuration, perform a Suspend/Resume on the MX7 Tecton.  
Summit Client Utility  
Note: When making changes to profile or global parameters, tap the power key to place the MX7 Tecton in Suspend. When the  
MX7 Tecton resumes from suspend the parameters are applied. The MX7 Tecton can be resumed by tapping the power  
key or the touch screen or by pressing any key.  
Select the Summit Client Utility using the Start button or tap the Summit Tray Icon (if present).  
The Main (page 11-5)provides information, admin login and active profile selection.  
Profile specific parameters are found on the Profile (page 11-8). The parameters on this tab can be set to unique values for each  
profile.  
The Status (page 11-11) contains information on the current connection.  
The Diags (page 11-12) provides utilities to troubleshoot the radio.  
Global parameters are found on theGlobal (page 11-13). The values for these parameters apply to all profiles.  
Help  
Help is available by tapping the ? icon in the title bar on most Summit Client Utility (SCU) screens.  
Help may also be accessed by selecting Start > Help and tapping the Summit Client Utility link. The SCU does not have to  
be open to view the help information using this option.  
11 - 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
             
Summit Tray Icon  
The Summit tray icon provides access to the SCU and is a visual indicator of radio status.  
The Summit tray icon is displayed when:  
The Summit radio is installed and active  
The Windows Zero Config utility is not active  
The Tray Icon setting is On  
Tap the icon to launch the SCU. Use the tray icon to view the radio status:  
The radio is not currently associated or authenticated to an Access Point  
The signal strength for the currently associated/authenticated Access Point is less than -90 dBm  
The signal strength for the currently associated/authenticated Access Point is -71 dBm to -90 dBm  
The signal strength for the currently associated/authenticated Access Point is -51 dBm to -70 dBm  
The signal strength for the currently associated/authenticated Access Point is greater than -50 dBm  
Using Windows Mobile Wireless Manager  
Using the Summit Client Utility to manage wireless connectivity is recommended. However, if desired, Windows Mobile  
includes the Wireless Manager utility to manage wireless network connections in place of the Summit Client Utility.  
To use the Windows Mobile Wireless Manager, first open the Summit Client Utility.  
1. Select ThirdPartyConfig in the Active Profile drop down box on the Main (page 11-5).  
2. A message appears that a Power Cycle is required to make settings activate properly.  
3. Tap OK.  
4. Open the Registry (page 5-45) panel and tap Warmboot.  
Access the Wireless Manager utility by tapping the radio icon at the top of the screen or tapping Start > Settings > Con-  
nections > Wi-Fi.  
If the Wi-Fi icon is not present in the Connections panel, return to the Summit Client Utility and select ThirdPartyConfig.  
Refer to the Windows Mobile help screens or online documentation for configuring wireless security using the Windows  
Mobile Wireless Manager.  
11 - 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Create a New Network Connection  
1. Tap on the Wi-Fi icon. A list of available networks is displayed.  
2. If the desired network is not displayed, tap Add New. If the desired network is displayed in the list, tap the network  
name.  
11 - 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3. Enter the SSID of the desired network in the Network name text box. Be sure to check the This is a hidden network  
check box for a non-broadcast SSID.  
4. In the Connects to box, select The Internet if the MX7 Tecton connects directly to the Internet, select Work if the  
MX7 Tecton connects to a network (even if the network provides an Internet connection).  
5. Tap Next.  
Edit a Network Connection  
Double tap the network name to edit the configuration or tap the network name and tap Connect to connect to the net-  
work.  
Network configuration screens are the same as displayed in the previous section.  
11 - 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Switch Control to SCU  
1. To switch back to SCU control, select any other profile except ThirdPartyConfig in the SCU Active Config drop  
down list on the Main tab.  
2. A message appears that a Power Cycle is required to make settings activate properly.  
3. Tap OK.  
4. Open the Registry panel and tap Warmboot. Radio control is passed to the Summit Client Utility.  
Main  
Setting  
Default  
Admin Login  
Radio  
SUMMIT  
Enabled  
Active Config/Profile  
Regulatory Domain  
Default  
Varies by location  
The Main tab displays information about the wireless client device including:  
SCU (Summit Client Utility) version  
Driver version  
Radio Type (ABG is an 802.11 a/b/g radio).  
Regulatory Domain is preset to either Worldwide or a location specific domain (FCC, ETSI, KCC or TELEC).  
Copyright Information can be accessed by tapping the About SCU button  
Active Config profile / Active Profile name  
Status of the client (Down, Associated, Authenticated, etc.).  
The Active Profile can be switched without logging in to Admin mode. Selecting a different profile from the drop down list  
does not require logging in to Administrator mode. The profile must already exist. Perform a Suspend/Resume function  
when changing profiles. Profiles can be created or edited after the Admin login password has been entered and accepted.  
When the profile named ThirdPartyConfig is chosen as the active profile, the Summit Client Utility passes control to Wire-  
less Manager for configuration of all client and security settings for the network module.  
The Disable Radio button can be used to disable the network card. Once disabled, the button label changes to Enable  
Radio. By default the radio is enabled.  
11 - 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
The Admin Login button provides access to editing wireless parameters. Profile and Global may only be edited after enter-  
ing the Admin Login password. The password is case-sensitive.  
Once logged in, the button label changes to Admin Logout. To logout, either tap the Admin Logout button or exit the SCU  
without tapping the Admin Logout button.  
Auto Profile  
Auto Profile allows the user to configure a list of profiles that the SCU can search when a radio connection is lost. After  
using the Profile tab to create any desired profiles, return to the Main tab. To specify which profiles are to be included  
in Auto Profile, tap the List button.  
The Auto Profile selection screen displays all currently configured profiles. Tap on the check box for any profiles that  
are to be included in Auto Profile selection then tap ok to save.  
To enable Auto Profile, tap the On button on the Main tab.  
When Auto Profile is On, if the radio goes out of range from the currently selected profile, the radio then begins to  
attempt to connect to the profiles listed under Auto Profile.  
The search continues until:  
the SCU connects to and, if necessary, authenticates with, one of the specified profiles or  
the Off button is tapped to turn off Auto Profile.  
Note: Do not include any profiles with an Ad Hoc Radio Mode in this listing.  
Admin Login  
To login to Administrator mode, tap the Admin Login button.  
Once logged in, the button label changes to Admin Logout. The admin is automatically logged out when the SCU is  
exited. The Admin can either tap the Admin Logout button, or the OK button to logout.  
11 - 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Enter the Admin password (the default password is SUMMIT and is case sensitive) and tap OK. If the password is  
incorrect, an error message is displayed.  
The Administrator default password can be changed on the Global (page 11-13).  
The end-user can:  
Turn the radio on or off on the Main tab.  
Select an active Profile on the Main tab.  
View the current parameter settings for the profiles on the Profile (page 11-8).  
View the global parameter settings on the Global (page 11-13).  
View the current connection details on the Status (page 11-11).  
View radio status, software versions and regulatory domain on the Main (page 11-5).  
Access additional troubleshooting features on the Diags (page 11-12).  
After Admin Login, the end-user can also:  
Create, edit, rename and delete profiles on the Profile (page 11-8).  
Edit global parameters on the Global (page 11-13).  
Enable/disable the Summit tray icon in the taskbar.  
11 - 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Profile  
Note: Tap the Commit button to save changes before leaving this panel or the SCU. If the panel is exited before tapping  
the Commit button, changes are not saved!  
Setting  
Default  
Profile  
Default  
SSID  
Blank  
Client Name  
Power Save  
Tx Power  
Bit Rate  
Blank  
Fast  
Maximum  
Auto  
Radio Mode  
Auth Type  
EAP Type  
Encryption  
Open  
None  
None  
When logged in as an Admin, see Admin Login (page 11-6), use the Profile tab to manage profiles. When not logged in as  
an Admin, the parameters can be viewed, and cannot be changed. The buttons on this tab are dimmed if the user is not  
logged in as Admin. The Profile tab was previously labeled Config.  
Note: The settings for Auth Type, EAP Type and Encryption depend on the security type chosen.  
11 - 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Buttons  
New Button  
Creates a new profile with the default settings (see Profile Parameters) and prompts for a unique name. If the name is  
not unique, an error message is displayed and the new profile is not created.  
Rename Button  
Assigns a new, unique name. If the new name is not unique, an error message is displayed and the profile is not  
renamed.  
Delete Button  
Deletes the profile. The current active profile cannot be deleted and an error message is displayed if a delete is  
attempted.  
WEP Keys / PSK Keys Button  
Allows entry of WEP keys or pass phrase as required by the type of encryption.  
Credentials Button  
Allows entry of a user name and password, certificate names, and other information required to authenticate with the  
access point. The information required depends on the EAP type.  
Commit Button  
Saves the profile settings made on this screen. Settings are saved in the profile.  
Scan Button  
Opens a window that lists access points that are broadcasting their SSIDs. Tap the Refresh button to view an updated  
list of APs. Each AP’s SSID, its received signal strength indication (RSSI) and whether or not data encryption is in use  
(true or false). Sort the list by tapping on the column headers. If you are logged in as an Admin, tap an SSID in the list  
and tap the Configure button, you return to the Profile window to recreate a profile for that SSID, with the profile name  
being the same as the SSID (or the SSID with a suffix such as “_1” if a profile with the SSID as its name exists  
already). If the scan finds more than one AP with the same SSID, the list displays the AP with the strongest RSSI and  
the least security.  
Note: Unsaved Changes – The SCU will display a reminder if the Commit button is not tapped before an attempt is  
made to close or browse away from this tab.  
11 - 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Profile Parameters  
Parameter Default  
Explanation  
Edit Profile Default  
A string of 1 to 32 alphanumeric characters, establishes the name of the Profile.  
Options are Default or ThirdPartyConfig.  
SSID  
Blank  
A string of up to 32 alphanumeric characters. Establishes the Service Set Identifier  
(SSID) of the WLAN to which the client connects.  
Client Name Blank  
Power Save Fast  
A string of up to 16 characters. The client name is assigned to the network card and  
the device using the network card. The client name may be passed to networking wire-  
less devices, e.g., Access Points.  
Power save mode is On.  
Options are: Constantly Awake Mode (CAM) power save off, Maximum (power saving  
mode) and Fast (power saving mode). When using power management, use FAST for  
best throughput results.  
Tx Power  
Bit Rate  
Maximum  
Maximum setting regulates Tx power to the Max power setting for the current regula-  
tory domain.  
Options are: Maximum, 50mW, 30mW, 20mW, 10mW, 5mW, or 1mW.  
Auto  
Setting the rate to Auto will allow the Access Point to automatically negotiate the bit  
rate with the client device.  
This parameter cannot be changed.  
Auth Type  
EAP Type  
Open  
None  
802.11 authentication type used when associating with the Access Point.  
Options are: Open, LEAP, or Shared key.  
Extensible Authentication Protocol (EAP) type used for 802.1x authentication to the  
Access Point.  
Options are: None, LEAP, EAP-FAST, PEAP-MSCHAP, PEAP-GTC, PEAP-TLS,  
EAP-TTLS, or EAP-TLS.  
Note: EAP Type chosen determines whether the Credentials button is active and also  
determines the available entries in the Credentials pop-up window.  
Encryption  
None  
Type of encryption to be used to protect transmitted data. Available options may vary  
by SCU version.  
Options are: None, WEP (or Manual WEP), WEP EAP (or Auto WEP), WPA PSK,  
WPA TKIP, WPA CCKM, WPA2 PSK, WPA2 AES, or WPA2 CCKM.  
CKIP is not supported in the MX7 Tecton.  
Note: The Encryption type chosen determines if the WEP Keys / PSK Keys button is  
active and also determines the available entries in the WEP or PSK pop-up  
window.  
Radio Mode BGA Rates Full Specify 802.11a, 802.11b and/or 802.11g rates when communicating with the AP. The  
options displayed for this parameter depend on the type of radio installed in the MX7  
Tecton.  
Options:  
B rates only (1, 2, 5.5 and 11 Mbps)  
BG Rates Full (All B and G rates  
G rates only (6, 9, 12, 18, 24, 36, 48 and 54 Mbps  
A rates only (6, 9, 12, 18, 24, 36, 48 and 54 Mbps  
ABG Rates Full (All A rates and all B and G rates with A rates preferred  
BGA Rates Full (All B and G rates and all A rates with B and G rates preferred  
Ad Hoc (when connecting to another client device instead of an AP)  
Default:  
BGA Rates Full (for 802.11a/b/g radio)  
Note: It is important the Radio Mode parameter correspond to the AP to which the  
device is to connect. For example, if this parameter is set to G rates only, the  
MX7 Tecton may only connect to APs set for G rates and not those set for B  
and G rates.  
11 - 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Status  
This screen provides information on the radio:  
The profile in use.  
The status of the radio card (down, associated, authenticated, etc.)  
Client information including device name, IP address and MAC address.  
Information about the Access Point (AP) maintaining the connection to the network including AP name, IP address and  
MAC address.  
Channel currently being used for wireless traffic.  
Bit rate in Mbit.  
Current transmit power in mW.  
Beacon period – the time between AP beacons in kilo-microseconds. (one kilo-microsecond = 1,024 microseconds).  
DTIM interval – A multiple of the beacon period that specifies how often the beacon contains a delivery traffic indication  
message (DTIM). The DTIM tells power saving devices a packet is waiting for them. For example, if DTIM = 3, then every  
third beacon contains a DTIM.  
Signal strength (RSSI) displayed in dBm and graphically.  
Signal quality, a measure of the clarity of the signal displayed in percentage and graphically.  
There are no user entries on this screen.  
Note: After completing radio configuration, it is a good idea to review this screen to verify the radio has associated (no  
encryption, WEP) or authenticated (LEAP, any WPA), as indicated above.  
11 - 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Diags  
The Diags screen can be used for troubleshooting network traffic and radio connectivity issues.  
(Re)connect – Use this button to apply (or reapply) the current profile and attempt to associate or authenticate to the  
wireless LAN. All activity is logged in the Diagnostic Output box on the lower part of the screen.  
Release/Renew – Obtain a new IP address through release and renew. All activity is logged in the Diagnostic Output  
box. If a fixed IP address has been assigned to the radio, this is also noted in the Diagnostic Output box. Note that the  
current IP address is displayed above this button.  
Start Ping – Start a continuous ping to the IP address specified in the text box to the right of this button. Once the button  
is tapped, the ping begins and the button label changes to Stop Ping. Tapping the button ends the ping. The ping also  
ends when any other button on this screen is tapped or the user browses away from the Diags tab. The results of the ping  
are displayed in the Diagnostic Output box.  
Diagnostics – Also attempts to (re)connect to the wireless LAN. However, this option provides more data in the  
Diagnostic Output box than the (Re)connect option. This data dump includes radio state, profile settings, global settings,  
and a list of broadcast SSID APs.  
Save To… – Use this to save the results of the diagnostics to a text file. Use the explorer window to specify the name  
and location for the diagnostic file. The text file can viewed using an application such as WordPad.  
11 - 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Global  
The parameters on this panel can only be changed when an Admin is logged in with a password. The current values for the  
parameters can be viewed by the general user without requiring a password.  
Note: Tap the Commit button to save changes. If the panel is exited before tapping the Commit button, changes are not  
saved!  
Setting  
Default  
-65 dBm  
5 dBm  
Roam Trigger  
Roam Delta  
Roam Period  
BG Channel Set  
DFS Channels  
DFS Scan Time  
Ad Hoc Channel  
Aggressive Scan  
CCX Features  
WMM  
10 sec.  
Full  
Off  
120 ms.  
1
On  
Optimized  
Off  
Auth Server  
TTLS Inner Method  
PMK Caching  
WAPI  
Type 1  
Auto-EAP  
Standard  
Off (dimmed)  
On  
TX Diversity  
RX Diversity  
Frag Threshold  
RTS Threshold  
LED  
On Start on Main  
2346  
2347  
Off  
Tray Icon  
On  
Hide Passwords  
Admin Password  
Auth Timeout  
Certs Path  
On  
SUMMIT (or blank)  
8 seconds  
System  
32 bytes  
5000 ms  
1000 ms  
Ping Payload  
Ping Timeout  
Ping Delay ms  
11 - 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Custom Parameter Option  
The parameter Custom option is not supported. The parameter value is displayed as “Custom” when the operating sys-  
tem registry has been edited to set the Summit parameter to a value that is not available from the parameter’s drop  
down list. Selecting Custom from the drop down list has no effect. Selecting any other value from the drop down list will  
overwrite the “custom” value in the registry.  
Global Parameters  
Parameter  
Default  
Function  
Roam Trigger  
-65 dBm  
If signal strength is less than this trigger value, the client looks for a different Ac-  
cess Point with a stronger signal.  
Roam Delta  
5 dBm  
The amount by which a different Access Point signal strength must exceed the  
current Access Point signal strength before roaming to the different Access  
Point is attempted.  
Roam Period  
10 sec.  
The amount of time, after association or a roam scan with no roam, that the ra-  
dio collects Received Signal Strength Indication (RSSI) scan data before a  
roaming decision is made.  
BG Channel Set Full  
Defines the 2.4GHz channels to be scanned for an AP when the radio is con-  
templating roaming. By specifying the channels to search, roaming time may be  
reduced over scanning all channels.  
Options are:  
Full (all channels)  
1,6,11 (the most commonly used channels)  
1,7,13 (for ETSI and TELEC radios only)  
DFS Channels  
Off  
Support for 5GHZ 802.11a channels where support for DFS is required.  
Options are: On, Off.  
Note: Not supported (always off) in some releases.  
DFS Scan Time 120 ms.  
The amount of time the radio will passively scan each DFS channel to see if it  
will receive a beacon.  
Recommended value is 1.5 times that of the AP's beacon period.  
11 - 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Parameter  
Default  
Function  
Ad Hoc Channel  
1
Use this parameter when the Radio Mode profile parameter is set to Ad Hoc.  
Specifies the channel to be used for an Ad Hoc connection to another client de-  
vice. If a channel is selected that is not supported by the by the radio, the default  
value is used.  
Options are:  
1 through 14 (the 2.4GHz channels)  
36, 40, 44, 48 (the UNII-1 channels)  
Aggressive Scan On  
When set to On and the current connection to an AP weakens, the radio aggres-  
sively scans for available APs.  
Aggressive scanning works with standard scanning (set through Roam Trigger,  
Roam Delta and Roam Period). Aggressive scanning should be set to On unless  
there is significant co-channel interference due to overlapping APs on the same  
channel.  
Options are: On, Off  
CCX Features  
WMM  
Optimized  
Use of Cisco Compatible Extensions (CCX) radio management and AP speci-  
fied maximum transmit power features.  
This parameter cannot be changed.  
Off  
Use of Wi-Fi Multimedia extensions.  
Options are: On, Off  
Default value cannot be changed.  
Auth Server  
Type 1  
Specifies the type of authentication server.  
Options are: Type 1 (ACS server) and Type 2 (non-ACS server)  
TTLS Inner  
Method  
Auto-EAP  
Authentication method used within the secure tunnel created by EAP-TTLS.  
Options are: AUTO-EAP (Any available EAP method), MSCHAPV2, MSCHAP,  
PAP, CHAP, EAP-MSCHAPV2  
PMK Caching  
Standard  
Type of Pairwise Master Key (PMK) caching to use when WPA2 is in use. PMK  
caching is designed to speed up roaming between APs by allowing the client  
and the AP to cache the results of 802.1X authentications, eliminating the need  
to communicate with the ACS server. Standard PMK is used when there are no  
controllers. The reauthentication information is cached on the original AP. The  
client and the AP use the cached information to perform the four-way hand-  
shake to exchange keys. Opportunistic PMK (OPMK) is used when there are  
controllers. The reauthentication information cached on the controllers. The cli-  
ent and the controller behind the AP use the cached information to perform the  
four-way handshake to exchange keys.  
If the selected PMK caching method is not supported by the network infrastruc-  
ture, every roam requires full 802.11X authentication, including interaction with  
the ACS server.  
If the active profile is using WPA2 CCKM, the global PMK Caching setting is ig-  
nored and the client attempts to use CCKM.  
Options are: Standard, OPMK  
Note: This change does not take effect until after a Suspend/Resume cycle.  
WAPI  
Off  
On  
Default is Off and dimmed (cannot be changed)  
TX Diversity  
How to handle antenna diversity when transmitting packets to the Access Point.  
Options are: Main only, and On.  
RX Diversity  
Frag Thresh  
On-Start on Main How to handle antenna diversity when receiving packets from the Access Point.  
Options are: On-Start on Main and Main only.  
2346  
2347  
If the packet size (in bytes) exceeds the specified number of bytes set in the  
fragment threshold, the packet is fragmented (sent as several pieces instead of  
as one block). Use a low setting in areas where communication is poor or where  
there is a great deal of wireless interference.  
This parameter cannot be changed.  
RTS Thresh  
If the packet size exceeds the specified number of bytes set in the Request to  
Send (RTS) threshold, an RTS is sent before sending the packet. A low RTS  
threshold setting can be useful in areas where many client devices are associ-  
ating with the Access Point.  
This parameter cannot be changed.  
11 - 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parameter  
Default  
Off  
Function  
LED  
The LED on the wireless card is not visible to the user when the wireless card  
is installed in a sealed mobile device.  
Options are: On, Off.  
This parameter cannot be changed.  
Tray Icon  
On  
On  
Determines if the Summit icon is displayed in the System tray.  
Options are: On, Off  
Hide Password  
When On, the Summit Config Utility masks passwords (characters on the  
screen are displayed as an *) as they are typed and when they are viewed.  
When Off, password characters are not masked.  
Options are: On, Off.  
Admin Password SUMMIT  
(or Blank)  
A string of up to 64 alphanumeric characters that must be entered when the Ad-  
min Login button is tapped. If Hide Password is On, the password is masked  
when typed in the Admin Password Entry dialog box. The password is case sen-  
sitive. This value is masked when the Admin is logged out.  
Options are: none.  
Auth Timeout  
8 seconds  
Specifies the number of seconds the Summit software waits for an EAP authen-  
tication request to succeed or fail.  
If the authentication credentials are stored in the active profile and the authen-  
tication times out, the association fails. No error message or prompting for cor-  
rected credentials is displayed.  
If the authentication credentials are not stored in the active profile and the au-  
thentication times out, the user is again prompted to enter the credentials.  
Options are: An integer from 3 to 60.  
Certs Path  
System  
A valid directory path, of up to 64 characters, where WPA Certificate Authority  
and User Certificates are stored on the mobile device when not using the Win-  
dows certificates store. Make sure the Windows folder path currently exists be-  
fore assigning the path in this parameter. See Certificates for instructions on  
obtaining CA and User Certificates. This value is masked when the Admin is  
logged out.  
Options are: none.  
For example, when the valid certificate is stored as My Computer/System/MY-  
CERTIFICATE.CER, enter System in the Certs Path text box as the Windows  
folder path.  
Ping Payload  
32 bytes  
Maximum amount of data to be transmitted on a ping.  
Options are: 32 bytes, 64, 128, 256, 512, or 1024 bytes.  
Ping Timeout ms 5000  
The amount of time, in milliseconds, that a device will be continuously pinged.  
The Stop Ping button can be tapped to end the ping process ahead of the ping  
timeout.  
Options are: Any number between 0 and 30000 ms.  
Ping Delay ms  
1000  
The amount of time, in milliseconds, between each ping after a Start Ping button  
tap.  
Options are: Any number between 0 and 30000 ms.  
Note: Tap the Commit button to save changes. If this panel is closed before tapping the Commit button, changes are  
not saved!  
11 - 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Sign-On vs. Stored Credentials  
When using wireless security that requires a user name and password to be entered, the Summit Client Utility offers the follow-  
ing choices:  
The Username and Password may be entered on the Credentials screen. If this method is selected, anyone using the device  
can access the network.  
The Username and Password are left blank on the Credentials screen. When the device attempts to connect to the network,  
a sign on screen is displayed. The user must enter the Username and Password at that time to authenticate.  
Using Stored Credentials  
1. After completing the other entries in the profile, tap on the Credentials button.  
2. Enter the Username and Password on the Credentials screen and tap the OK button.  
3. Tap the Commit button.  
4. For LEAP and WPA/LEAP, configuration is complete.  
5. For PEAP-MSCHAP and PEAP-GTC, importing the CA certificate into the Windows certificate store is optional.  
6. For EAP-TLS, import the CA certificate into the Windows certificate store. Also import the User Certificate into the  
Windows certificate store.  
7. Access the Credentials screen again. Make sure the Validate server and Use MS store checkboxes are checked.  
8. The default is to use the entire certificate store for the CA certificate. Alternatively, use the Browse button next to the CA  
Cert (CA Certificate Filename) on the Credentials screen to select an individual certificate.  
9. For EAP-TLS, also enter the User Cert (User Certificate filename) on the credentials screen by using the Browse button.  
10. If using EAP FAST and manual PAC provisioning, input the PAC filename and password..  
11. Tap the OK button then the Commit button.  
12. If changes are made to the stored credentials, tap Commit to save those changes before making any additional  
changes to the profile or global parameters.  
13. Verify the device is authenticated by reviewing the Status tab. When the device is property configured, the Status tab  
indicates the device is Authenticated and the method used.  
Note: See Configuring Profiles (page 11-21) for more details.  
Note: If invalid credentials are entered into the stored credentials, the authentication will fail. No error message is displayed.  
The user may or may not be prompted to enter valid credentials.  
Using a Sign On Screen  
1. After completing the other entries in the profile, tap on the Credentials button. Leave the Username and Password  
blank. No entries are necessary on the Credentials screen for LEAP or LEAP/WPA.  
2. For PEAP-MSCHAP and PEAP-GTC, importing the CA certificate into the Windows certificate store is optional.  
3. For EAP-TLS, import the CA certificate into the Windows certificate store. Also import the User Certificate into the  
Windows certificate store.  
4. Access the Credentials screen again. Make sure the Validate server and Use MS store checkboxes are checked.  
5. The default is to use the entire certificate store for the CA certificate. Alternatively, use the Browse button next to the CA  
Cert (CA Certificate Filename) on the Credentials screen to select an individual certificate.  
6. For EAP-TLS, also enter the User Cert (User Certificate filename) on the credentials screen by using the Browse button.  
7. Tap the OK button then the Commit button.  
8. When the device attempts to connect to the network, a sign-on screen is displayed.  
9. Enter the Username and Password. Tap the OK button.  
11 - 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
10. Verify the device is authenticated by reviewing the Status tab. When the device is property configured, the Status  
(page 11-11) indicates the device is Authenticated and the method used.  
11. The sign-on screen is displayed after a reboot.  
Note: See Configuring Profiles (page 11-21) for more details.  
If a user enters invalid credentials and clicks OK, the device associates but does not authenticate. The user is again  
prompted to enter credentials.  
If the user clicks the Cancel button, the device does not associate. The user is not prompted again for credentials until:  
the device is rebooted,  
the radio is disabled then enabled,  
the Reconnect button on the Diags Tab is tapped or  
the profile is modified and the Commit button is tapped.  
11 - 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Windows Certificate Store vs. Certs Path  
Note: It is important that all dates are correct on the MX7 Tecton and host computers when using any type of certificate.  
Certificates are date sensitive and if the date is not correct authentication will fail.  
User Certificates  
EAP-TLS authentication requires a user certificate. The user certificate must be stored in the Windows certificate store.  
To generate the user certificate, see Generating a User Certificate (page 11-39).  
To import the user certificate into the Windows certificate store, see Installing a User Certificate (page 11-43).  
A Root CA certificate is also needed. Refer to the section below.  
Root CA Certificates  
Root CA certificates are required for EAP/TLS, PEAP/GTC and PEAP/MSCHAP. Two options are offered for storing these  
certificates:  
Imported into the Windows certificate store.  
Copied into the Certs Path directory.  
Using the Certs Path  
1. See Generating a Root CA Certificate (page 11-36) and follow the instructions to download the Root Certificate to a  
PC.  
2. Copy the certificate to specified directory on the mobile device. The default location for Certs Path is \System. A dif-  
ferent location may be specified by using the Certs Path global variable. Note the location chosen for certificate  
storage should persist after a reboot.  
3. When completing the Credentials screen for the desired authentication, do not check the Use MS store check box  
after tapping the Validate server check box.  
4. Enter the certificate name in the CA Cert textbox.  
5. Tap OK to exit the Credentials screen and then Commit to save the profile changes.  
Using the Windows Certificate Store  
1. See Generating a Root CA Certificate (page 11-36) and follow the instructions to download the Root Certificate to a  
PC.  
2. To import the certificate into the Windows store, see Installing a Root CA Certificate (page 11-39).  
3. When completing the Credentials screen for the desired authentication, be sure to check the Use MS store check  
box after tapping the Validate server check box.  
4. The default is to use all certificates in the store. If this is OK, skip to the last step.  
5. Otherwise, to select a specific certificate tap on the Browse (…) button.  
11 - 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
6. Uncheck the Use full trusted store check box.  
7. Select the desired certificate and tap the Select button to return the selected certificate to the CA Cert textbox.  
8. Tap OK to exit the Credentials screen and then Commit to save the profile changes.  
11 - 20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configuring Profiles  
Use the instructions in this section to complete the entries on the Profile tab according to the type of wireless security used by  
your network. The instructions that follow are the minimum required to successfully connect to a network. Your system may  
require more parameters than are listed in these instructions.See your system administrator for complete information about your  
network and its wireless security requirements.  
To begin the configuration process:  
1. On the Main Tab, tap the Admin Login button and enter the password.  
2. Edit the default profile with the parameters for your network. Select the Default profile from the pull down menu.  
3. Make any desired parameter changes as described in the applicable following section determined by network security type  
and tap the Commit button to save the changes.  
IMPORTANT – Remember to tap the Commit button after making changes to ensure the changes are saved. Many versions of  
the SCU display a reminder if the Commit button is not tapped before an attempt is made to close or browse away from the tab  
in focus if there are unsaved changes.  
If changes are made to the stored credentials, tap Commit to save those changes first before making any additional changes.  
No Security  
To connect to a wireless network with no security, make sure the following profile options are used.  
1. Enter the SSID of the Access Point assigned to this profile.  
2. Set EAP Type to None.  
3. Set Encryption to None.  
4. Set Auth Type to Open.  
5. Once configured, tap the Commit button.  
6. Ensure the correct Active Profile is selected on the Main Tab and perform a Suspend/Resume. The SCU Main tab  
shows the device is associated after the radio connects to the network.  
11 - 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
WEP  
To connect using WEP, make sure the following profile options are used.  
1. Enter the SSID of the Access Point assigned to this profile.  
2. Set EAP Type to None.  
3. Set Encryption to WEP or Manual WEP (depending on SCU version).  
4. Set Auth Type to Open.  
5. Tap the WEP keys/PSKs button.  
6. Valid keys are 10 hexadecimal or 5 ASCII characters (for 40-bit encryption) or 26 hexadecimal or 13 ASCII characters  
(for 128-bit encryption). Enter the key(s) and tap OK.  
7. Once configured, tap the Commit button.  
8. Ensure the correct Active Profile is selected on the Main Tab and perform a Suspend/Resume. The SCU Main tab  
shows the device is associated after the radio connects to the network.  
11 - 22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
LEAP  
To use LEAP (without WPA), make sure the following profile options are used.  
1. Enter the SSID of the Access Point assigned to this profile.  
2. Set EAP Type to LEAP.  
3. Set Encryption to WEP EAP or Auto WEP (depending on SCU version).  
4. Set Auth Type as follows:  
If the Cisco/CCX certified AP is configured for open authentication, set the Auth Type radio parameter to Open.  
If the AP is configured to use shared key or passphrase, set the Auth Type radio parameter to Shared.  
If the AP is configured for network EAP only, set the Auth Type radio parameter to LEAP.  
6. To use Stored Credentials, tap on the Credentials button. No entries are necessary for Sign-On Credentials as the user  
will be prompted for the Username and Password when connecting to the network.  
7. Enter the Domain\Username (if the Domain is required), otherwise enter the Username.  
8. Enter the password.  
11 - 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
9. Tap OK then tap Commit.  
10. Ensure the correct Active Profile is selected on the Main Tab and perform a Suspend/Resume. The SCU Main tab  
shows the device is associated after the radio connects to the network.  
11 - 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PEAP/MSCHAP  
Note: The date must be properly set on the device to authenticate a certificate.  
To use PEAP/MSCHAP, make sure the following profile options are used.  
1. Enter the SSID of the Access Point assigned to this profile.  
2. Set EAP Type to PEAP-MSCHAP.  
3. Set Encryption to WPA TKIP.  
4. Set Auth Type to Open.  
5. To use another encryption type, select WPA CCKM, WPA2 AES or WPA2 CCKM for encryption and complete other  
entries as detailed in this section.  
7. Tap the Credentials button.  
No entries except the CA Certificate Filename are necessary for Sign-On Credentials as the user will be prompted  
for the User Name and Password when connecting to the network.  
For Stored Credentials, User, Password and the CA Certificate Filename must be entered.  
8. Enter these items as directed below.  
11 - 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
9. Enter the Domain\Username (if the Domain is required), otherwise enter the Username.  
10. Enter the password.  
11. Leave the CA Certificate File Name blank for now.  
12. Tap OK then tap Commit. Ensure the correct Active profile is selected on the Main Tab.  
13. See Windows Certificate Store vs. Certs Path (page 11-19) for more information on certificate storage.  
14. Once successfully authenticated, import the CA certificate into the Windows certificate store.  
15. Return to the Credentials screen and check the Validate server check box.  
If using the Windows certificate store:  
1. Tap the Use MS store check box. The default is to use the Full Trusted Store.  
2. To select an individual certificate, tap on the Browse button.  
3. Uncheck the Use full trusted store check box.  
4. Select the desired certificate and tap Select. You are returned to the Credentials screen.  
If using the Certs Path option:  
1. Leave the Use MS store box unchecked.  
2. Enter the certificate filename in the CA Cert textbox.  
After using the selected option (Windows certificate store or Certs Path), tap OK then tap Commit.  
The device should be authenticating the server certificate and using PEAP/MSCHAP for the user authentication.  
Ensure the correct Active Profile is selected on the Main Tab and perform a Suspend/Resume. The SCU Main tab shows  
the device is associated after the radio connects to the network.  
11 - 26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PEAP/GTC  
Note: The date must be properly set on the device to authenticate a certificate.  
To use PEAP/GTC, make sure the following profile options are used.  
1. Enter the SSID of the Access Point assigned to this profile.  
2. Set EAP Type to PEAP-GTC.  
3. Set Encryption to WPA TKIP.  
4. Set Auth Type to Open.  
5. To use another encryption type, select WPA CCKM, WPA2 AES or WPA2 CCKM for encryption and complete other  
entries as detailed in this section.  
7. Tap the Credentials button. No entries except the CA Certificate Filename are necessary for Sign-On Credentials as the  
user will be prompted for the User Name and Password when connecting to the network.  
8. Enter these items as directed below.  
9. Enter the Domain\Username (if the Domain is required), otherwise enter the Username.  
10. Enter the password.  
11 - 27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
11. Leave the CA Certificate File Name blank for now.  
12. Tap OK then tap Commit. Ensure the correct Active Profile is selected on the Main Tab.  
13. See Windows Certificate Store vs. Certs Path (page 11-19) for more information on certificate storage.  
14. Once successfully authenticated, import the CA certificate into the Windows certificate store.  
15. Return to the Credentials screen and check the Validate server check box.  
If using the Windows certificate store:  
1. Tap the Use MS store check box. The default is to use the Full Trusted Store.  
2. To select an individual certificate, tap on the Browse button.  
3. Uncheck the Use full trusted store check box.  
4. Select the desired certificate and tap Select. You are returned to the Credentials screen.  
If using the Certs Path option:  
1. Leave the Use MS store box unchecked.  
2. Enter the certificate filename in the CA Cert textbox.  
After using the selected option (Windows certificate store or Certs Path), tap OK then tap Commit.  
The device should be authenticating the server certificate and using PEAP/GTC for the user authentication.  
Ensure the correct Active Profile is selected on the Main Tab and perform a Suspend/Resume. The SCU Main tab shows  
the device is associated after the radio connects to the network.  
11 - 28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WPA/LEAP  
To use WPA/LEAP, make sure the following profile options are used.  
1. Enter the SSID of the Access Point assigned to this profile.  
2. Set EAP Type to LEAP.  
3. Set Encryption to WPA TKIP.  
4. Set Auth Type as follows:  
If the Cisco/CCX certified AP is configured for open authentication, set the Auth Type radio parameter to Open.  
If the AP is configured to use shared key or passphrase, set the Auth Type radio parameter to Shared.  
If the AP is configured for network EAP only, set the Auth Type radio parameter to LEAP.  
5. To use another encryption type, select WPA CCKM, WPA2 AES or WPA2 CCKM for encryption and complete other  
entries as detailed in this section.  
7. To use Stored Credentials, tap on the Credentials button. No entries are necessary for Sign-On Credentials as the user  
will be prompted for the Username and Password when connecting to the network.  
8. Enter the Domain\Username (if the Domain is required), otherwise enter the Username.  
11 - 29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
9. Enter the password.  
10. Tap OK then tap the Commit button.  
11. Ensure the correct Active Profile is selected on the Main Tab and perform a Suspend/Resume. The SCU Main tab  
shows the device is associated after the radio connects to the network.  
11 - 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EAP-FAST  
The SCU supports EAP-FAST with automatic or manual PAC provisioning. With automatic PAC provisioning, the user cre-  
dentials, whether entered on the saved credentials screen or the sign on screen, are sent to the RADIUS server. The  
RADIUS server must have auto provisioning enabled to send the PAC provisioning credentials to the MX7 Tecton.  
For automatic PAC provisioning, once a username/password is authenticated, the PAC information is stored on the MX7  
Tecton. The same username/password must be used to authenticate each time. See the note below for more details.  
Note: When using Automatic PAC Provisioning, once authenticated, there is a file stored in the \System folder with the PAC  
credentials. If the username is changed, that file must be deleted. The filename is autoP.00.pac.  
For manual PAC provisioning, the PAC filename and Password must be entered.  
To use EAP-FAST, make sure the following profile options are used.  
1. Enter the SSID of the Access Point assigned to this profile.  
2. Set EAP Type to EAP-FAST.  
3. Set Encryption to WPA TKIP.  
4. Set Auth Type to Open.  
5. To use another encryption type, select WPA CCKM, WPA2 AES or WPA2 CCKM for encryption and complete other  
entries as detailed in this section.  
6. See Sign-On vs. Stored Credentials (page 11-17)for information on entering credentials. The entries on the Credentials  
screen are determined by the type of credentials (stored or sign on) and the type of PAC provisioning (automatic or  
manual).  
7. Tap on the Credentials button.  
11 - 31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
8. To use Stored Credentials, tap on the Credentials button. No entries are necessary for Sign-On Credentials with  
automatic PAC provisioning as the user will be prompted for the Username and Password when connecting to the  
network.  
9. To use Sign-On credentials:  
Do not enter a User and Password as the user will be prompted for the Username and Password when connecting  
to the network.  
10. To use Stored Credentials:  
Enter the Domain\Username (if the Domain is required), otherwise enter the Username.  
Enter the password.  
11. To use Automatic PAC Provisioning no additional entries are required.  
12. To use manual PAC Provisioning:  
Enter the PAC Filename and PAC Password.  
The PAC file must be copied to the directory specified in the Certs Path global variable. The PAC file must not be  
read only.  
13. Ensure the correct Active Profile is selected on the Main Tab and perform a Suspend/Resume. The SCU Main tab  
shows the device is associated after the radio connects to the network.  
11 - 32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EAP-TLS  
Note: The date must be properly set on the device to authenticate a certificate.  
To use EAP-TLS, make sure the following profile options are used.  
1. Enter the SSID of the Access Point assigned to this profile.  
2. Set EAP Type to EAP-TLS.  
3. Set Encryption to WPA TKIP.  
4. Set Auth Type to Open.  
5. To use another encryption type, select WPA CCKM, WPA2 AES or WPA2 CCKM for encryption and complete other  
entries as detailed in this section.  
7. Tap the Credentials button.  
No entries except the User Certificate Filename and the CA Certificate Filename are necessary for Sign-On  
Credentials as the user will be prompted for the User Name when connecting to the network.  
For Stored Credentials, User and the CA Certificate Filename must be entered.  
8. Enter these items as directed below.  
11 - 33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
9. Enter the Domain\Username (if the Domain is required), otherwise enter the User name.  
10. Select a user certificate from the Windows certificate store. Use the Browse button to locate the User Cert from the  
certificate store. Highlight the desired certificate and press the Select button. The name of the certificate is displayed in  
the User Cert box.  
11. Some versions of the SCU require a User Cert password. If this entry field is present, enter the password for the user  
certificate in the User Cert pwd box.  
12. If there are no user certificates in the Windows certificate store, generate and install a user certificate.  
13. See Windows Certificate Store vs. Certs Path (page 11-19) for more information on CA certificate storage.  
14. Tap the Validate server check box.  
If using the Windows certificate store:  
1. Tap the Use MS store check box. The default is to use the Full Trusted Store.  
2. To select an individual certificate, tap on the Browse button.  
3. Uncheck the Use full trusted store check box.  
4. Select the desired certificate and tap Select. You are returned to the Credentials screen.  
If using the Certs Path option:  
1. Leave the Use MS store box unchecked.  
2. Enter the certificate filename in the CA Cert textbox.  
After using the selected option (Windows certificate store or Certs Path), tap OK then tap Commit.  
The MX7 Tecton should be authenticating the server certificate and using EAP-TLS for the user authentication.  
Ensure the correct Active Profile is selected on the Main Tab and perform a Suspend/Resume. The SCU Main tab shows  
the device is associated after the radio connects to the network.  
Generate a Root CA certificate or a User certificate.  
11 - 34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WPA PSK  
To connect using WPA/PSK, make sure the following profile options are used:  
1. Enter the SSID of the Access Point assigned to this profile.  
2. Set EAP Type to None.  
3. Set Encryption to WPA PSK or WPA2 PSK.  
4. Set Auth Type to Open.  
5. Tap the WEP keys/PSKs button.  
6. This value can be 64 hex characters or an 8 to 63 byte ASCII value. Enter the key and tap OK.  
7. Once configured, tap the Commit button.  
8. Ensure the correct Active Profile is selected on the Main Tab and perform a Suspend/Resume. The SCU Main tab  
shows the device is associated after the radio connects to the network.  
11 - 35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Certificates  
Note: Refer to the Security Primer (available on the Honeywell web site) to prepare the Authentication Server and Access Point  
for communication.  
Note: It is important that all dates are correct on the MX7 Tecton and host computers when using any type of certificate.  
Certificates are date sensitive and if the date is not correct authentication will fail.  
Root Certificates are necessary for EAP-TLS, PEAP/GTC and PEAP/MSCHAP.  
1. See Generating a Root CA Certificate (page 11-36) and download it to a PC.  
2. Connect the MX7 Tecton to the desktop PC using ActiveSync and copy the certificate to the MX7 Tecton \System folder.  
3. See Installing a Root CA Certificate (page 11-39) and install the Root CA Certificate.  
User Certificates are necessary for EAP-TLS.  
1. See Generating a User Certificate (page 11-39) and download it to a PC.  
2. Install the User Certificate on the PC.  
3. See Exporting a User Certificate (page 11-42) and export the User Certificate as a .PFX file.  
4. Connect the MX7 Tecton to the desktop PC using ActiveSync and copy the certificate to the MX7 Tecton \System folder.  
5. See Installing a User Certificate (page 11-43) and install the User Certificate.  
6. After installation, perform a Suspend/Resume.  
Generating a Root CA Certificate  
Note: It is important that all dates are correct on the MX7 Tecton and host computers when using any type of certificate.  
Certificates are date sensitive and if the date is not correct authentication will fail.  
The easiest way to get the root CA certificate is to use a browser on a PC to navigate to the Certificate Authority.  
1. To request the root CA certificate, open a browser to http://<CA IP address>/certsrv.  
2. Sign into the CA with any valid username and password.  
11 - 36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
3. Tap the Download a CA certificate, certificate chain or CRL link.  
4. Make sure the correct root CA certificate is selected in the list box.  
11 - 37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Tap the DER button.  
6. To download the CA certificate, tap on the Download CA certificate link.  
7. Tap the Save button and save the certificate. Make sure to keep track of the name and location of the certificate.  
11 - 38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. Install the Root CA Certificate on the MX7 Tecton.  
Installing a Root CA Certificate  
Note: This section is only if the Windows certificate store is used. If the certificate store is not used, copy the certificate to  
the \System folder or other path specified in the Summit Certs global parameter.  
1. Copy the certificate file to the MX7 Tecton. The certificate file has a .CER extension. Locate the file and tap it.  
2. A certificate installation warning text box is displayed:  
Your device is being asked to install a security certificate. You should block unless you require certificates for  
processes such as synchronizing with Exchange Server or connecting to a wireless network.  
3. Tap More to view the remainder of the warning in the text box:  
Installing the certificate will cause your device to trust digital certificates from the requester. Malicious requesters may  
try to mislead you about their identity. Do you want to block this certificate?  
4. Tap Install to continue the installation. An installation successful message is displayed.  
You can view any installed user certificates by selecting Start > Settings > System and tapping the Certificates icon.  
Installed root certificates are displayed on the Root tab.  
Generating a User Certificate  
The easiest way to get the user certificate is to use the browser on a PC to navigate to the Certificate Authority.  
1. To request the user certificate, open a browser to http://<CA IP address>/certsrv.  
2. Sign into the CA with the username and password of the person who will be logging into the mobile device.  
3. This process saves a user certificate file. A separate private key file is not required.  
11 - 39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
4. Tap the Request a certificate link.  
5. Tap the User Certificate link.  
11 - 40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Tap on the Submit button. if there is a message box asking if you want to confirm the request, tap Yes.  
7. The User Certificate is issued.  
8. Install the user certificate on the requesting computer by tapping the Install this certificate link.  
9. Export the certificate as described below.  
11 - 41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Exporting a User Certificate  
1. Start Internet Explore on the PC that requested the certificate.  
2. Select Tools > Internet Options > Content and tap the Certificates button.  
3. Make sure the Personal tab is selected. Highlight the certificate and tap the Export button.  
4. The Certificate Export Wizard is started  
5. Select Yes, export the private key and tap Next.  
6. Uncheck Enable strong protection and check Next. The certificate type must be PKCS #12 (.PFX).  
11 - 42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
7. When the private key is exported, you must enter the password, confirm the password and tap Next. Be sure to  
remember the password as it is needed when installing the certificate.  
8. Supply the file name for the certificate. Use the Browse button to select the folder where you wish to store the certificate.  
The certificate is saved with a .PFX extension.  
9. Tap Finish and OK to close the Successful Export message.  
10. Locate the User Certificate in the specified location. Copy to the MX7 Tecton.  
11. Install the User Certificate.  
Installing a User Certificate  
1. After generating and exporting the user certificate, copy it from the PC to the MX7 Tecton. Copy the certificate to a loca-  
tion on the MX7 Tecton, such as a storage card or the \System folder.  
2. Locate the certificate file (it has a .PFX extension) and tap on it. You are prompted for the password that was assigned  
when the certificate was exported.  
3. Enter the password and tap Done. A message is displayed that the certificate installation was successful.  
Verify Installation  
1. You can view any installed user certificates by selecting Start > Settings > System and tapping the Certificates icon.  
2. Installed user certificates are displayed on the Personal tab.  
11 - 43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
11 - 44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12  
Keymaps  
Introduction  
Sticky keys are also known as second function keys. Ctl/Ctrl, Alt, Shft, Blue and Orange keys are sticky keys. Sticky keys do not  
need to be held down before pressing the next (or desired) key. You can use combined modifiers on specific keys.  
The key mapping in this section relates to the physical Keypads (page 3-4). See the Input Panel for the Virtual (or Soft) Keypad  
used with the stylus.  
55 key Alphanumeric Keymap - Primary Delete  
The following keymap is used on an MX7 Tecton that is NOT running a Terminal  
Emulator. Terminal emulators use a separate keymap.  
When using a sequence of keys that includes a sticky key, press the sticky key first,  
release it, then press the rest of the key sequence.  
When using a sequence of keys that includes the Orange or Blue keys, press the color  
key first then the rest of the key sequence.  
Tapping the Power key when in any sticky mode (Blue, Orange, Shift, etc.) either turns  
the device On (when Off) or places it in Suspend (when On).  
Alphabetic keys default to lower case letters. Press the Shft key, then the alphabetic key  
for an uppercase letter.  
The diamond 1, F1, F2, F3, F4 and F5 keys can be remapped using the Button panel  
(Start > Settings > Personal > Buttons).  
When the computer boots, the default condition of Caps (or CapsLock) is Off. The Caps  
(or CapsLock) condition can be toggled with Blue plus Tab key sequence.  
To get this Key / Function  
Press these Keys in this Order  
Power / Suspend  
Power  
Field Exit (default VK_PAUSE)  
MAP = Mappable  
Blue (MAP)  
Orange (MAP) Shift (MAP)  
Diamond #1  
Volume Adjust Mode  
Orange  
Blue  
Blue  
Blue  
Orange  
Shft  
Scan  
V
Up Arrow / Down Arrow  
Up Arrow / Down Arrow  
Volume Adjust Mode  
Display Backlight Brightness Adjust Mode  
Scan  
Toggle Blue Mode  
Toggle Orange Mode  
Toggle Shift Mode  
Alt  
Alt  
Control  
Ctl  
Esc  
Blue  
Spc  
Alt  
Space  
Enter  
Enter  
Scan  
Blue  
Orange  
Scan  
CapsLock (Toggle)  
Back Space  
Tab  
Spc  
12 - 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
To get this Key / Function  
Press these Keys in this Order  
Tab  
Tab  
Back Tab  
Up Arrow  
Down Arrow  
Right Arrow  
Left Arrow  
Insert  
Insert  
Delete  
Home  
End  
Orange  
Up Arrow  
Down Arrow  
Right Arrow  
Left Arrow  
Blue  
Tab  
I (letter i)  
Ctl  
Orange  
Del  
Shft  
Down Arrow  
Up Arrow  
Shft  
Page Up  
Page Down  
F1  
Orange  
Orange  
F1  
Up Arrow  
Down Arrow  
F2  
F2  
F3  
F3  
F4  
F4  
F5  
F5  
F6  
Orange  
Orange  
Orange  
Orange  
Orange  
Blue  
F1  
F7  
F2  
F8  
F3  
F9  
F4  
F10  
F5  
F11  
F1  
F12  
Blue  
F2  
F13  
Blue  
F3  
F14  
Blue  
F4  
F15  
Blue  
F5  
F16  
Shft  
F1  
F17  
Shft  
F2  
F18  
Shft  
F3  
F19  
Shft  
F4  
F20  
Shft  
F5  
F21  
Shft  
Orange  
Orange  
Orange  
Orange  
F1  
F2  
F3  
F4  
F22  
Shft  
F23  
Shft  
F24  
Shft  
a
A
b
B
c
C
d
D
12 - 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To get this Key / Function  
Press these Keys in this Order  
e
E
f
F
g
h
i
G
H
I
j
J
k
K
l
L
m
n
o
p
q
r
M
N
O
P
Q
R
s
S
t
T
u
v
U
V
w
x
W
X
y
Y
z
Z
A
B
C
D
E
F
G
H
I
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
A
B
C
D
E
F
G
H
I
J
J
K
L
M
N
O
P
Q
R
S
K
L
M
N
O
P
Q
R
S
12 - 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To get this Key / Function  
Press these Keys in this Order  
T
Shft  
T
U
Shft  
U
V
W
X
Y
Z
V
Shft  
W
Shft  
X
Shft  
Y
Shft  
Z
Shft  
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
0
0
. (period)  
Orange  
Orange  
Blue  
Blue  
Blue  
Blue  
Blue  
Blue  
Blue  
Blue  
Blue  
Blue  
Orange  
Shft  
DEL  
K
. (period  
<
G
[
Y
]
Z
>
H
=
T
{
W
X
}
/
J
-
Spc  
Del  
+
* (asterisk)  
* (asterisk)  
: (colon)  
; (semicolon)  
?
I (letter i)  
8
Orange  
Orange  
Orange  
Orange  
Orange  
Orange  
Orange  
Orange  
Orange  
Orange  
D
F
L
` (accent)  
_ (underscore)  
, (comma)  
' (apostrophe)  
~ (tilde)  
\
N
M
J
H
B
S
A
|
12 - 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To get this Key / Function  
Press these Keys in this Order  
"
Orange  
Orange  
Shft  
G
Q
1
!
!
@
@
#
#
$
$
%
%
^
Orange  
Shft  
W
2
Orange  
Shft  
E
3
Orange  
Shft  
R
4
Blue  
R
T
5
Orange  
Shft  
Orange  
Shft  
Y
6
^
&
&
(
Orange  
Shft  
U
7
Orange  
Shft  
O
9
(
)
Orange  
Shft  
P
)
0 (zero)  
12 - 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
55 Key 5250 Alphanumeric KeyMap - Primary Delete  
The following keymap is used on an MX7 Tecton that is running a 5250 Terminal  
Emulator.  
When using a sequence of keys that includes a sticky key, press the sticky key first,  
release it, then press the rest of the key sequence.  
When using a sequence of keys that includes the Orange or Blue keys, press the color  
key first then the rest of the key sequence.  
Tapping the Power key when in any sticky mode (Blue, Orange, Shift, etc.) either turns  
the device On (when Off) or places it in Suspend (when On).  
Alphabetic keys default to lower case letters. Press the Shft key, then the alphabetic key  
for an uppercase letter.  
The diamond 1, F1, F2, F3, F4 and F5 keys can be remapped using the Button panel  
(Start > Settings > Personal > Buttons).  
When the computer boots, the default condition of Caps (or CapsLock) is Off. The Caps  
(or CapsLock) condition can be toggled with Blue plus Tab key sequence  
.
To get this 5250 Key / Function  
Attn (Attention)  
Press these Keys in this Order  
Ctl  
A
C
D
U
Q
Clr (Clear)  
Ctl  
Del (Delete)  
Ctl  
Dup (Duplicate)  
Ctl  
E-Inp (Erase Input)  
Field Exit (Enter)  
Fld - (Field Minus)  
Fld + (Field Plus)  
Ins (Insert)  
Ctl  
Diamond 1  
Ctl  
Ctl  
Ctl  
Ctl  
Ctl  
M
L
I
NL (New Line)  
N
S
SysReq (System)  
The following are ANSI keymaps  
Power / Suspend  
Power  
Field Exit (default VK_PAUSE)  
MAP = Mappable  
Blue (MAP)  
Orange (MAP) Shift (MAP)  
Diamond #1  
Volume Adjust Mode  
Orange  
Blue  
Blue  
Blue  
Orange  
Shft  
Scan  
V
Up Arrow / Down Arrow  
Up Arrow / Down Arrow  
Volume Adjust Mode  
Display Backlight Brightness Adjust Mode  
Scan  
Toggle Blue Mode  
Toggle Orange Mode  
Toggle Shift Mode  
Alt  
Alt  
Control  
Ctl  
Esc  
Blue  
Alt  
12 - 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
To get this 5250 Key / Function  
Press these Keys in this Order  
Space  
Enter  
Scan  
CapsLock (Toggle)  
Back Space  
Tab  
Spc  
Enter  
Scan  
Blue  
Tab  
Spc  
Orange  
Tab  
Back Tab  
Up Arrow  
Down Arrow  
Right Arrow  
Left Arrow  
Insert  
Insert  
Delete  
Home  
End  
Orange  
Up Arrow  
Down Arrow  
Right Arrow  
Left Arrow  
Blue  
Tab  
I (letter i)  
Ctl  
Orange  
Del  
Shft  
Down Arrow  
Up Arrow  
Shft  
Page Up  
Page Down  
F1  
Orange  
Orange  
F1  
Up Arrow  
Down Arrow  
F2  
F2  
F3  
F3  
F4  
F4  
F5  
F5  
F6  
Orange  
Orange  
Orange  
Orange  
Orange  
Blue  
F1  
F7  
F2  
F8  
F3  
F9  
F4  
F10  
F5  
F11  
F1  
F12  
Blue  
F2  
F13  
Blue  
F3  
F14  
Blue  
F4  
F15  
Blue  
F5  
F16  
Shft  
F1  
F17  
Shft  
F2  
F18  
Shft  
F3  
F19  
Shft  
F4  
F20  
Shft  
F5  
F21  
Shft  
Orange  
Orange  
Orange  
F1  
F2  
F3  
F22  
Shft  
F23  
Shft  
12 - 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To get this 5250 Key / Function  
Press these Keys in this Order  
Orange F4  
F24  
a
b
c
Shft  
A
B
C
d
e
f
D
E
F
g
h
i
G
H
I
j
J
k
K
l
L
m
n
o
p
q
r
M
N
O
P
Q
R
s
S
t
T
u
v
U
V
w
x
W
X
y
Y
z
Z
A
B
C
D
E
F
G
H
I
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
A
B
C
D
E
F
G
H
I
J
J
K
L
M
N
K
L
M
N
12 - 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To get this 5250 Key / Function  
Press these Keys in this Order  
O
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
1
O
P
Q
R
S
T
P
Q
R
S
T
U
U
V
W
X
Y
Z
V
W
X
Y
Z
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
0
0
. (period)  
Orange  
Orange  
Blue  
Blue  
Blue  
Blue  
Blue  
Blue  
Blue  
Blue  
Blue  
Blue  
Orange  
Shft  
Orange  
Orange  
Orange  
Orange  
Orange  
DEL  
K
. (period  
<
G
[
Y
]
Z
>
H
=
T
{
W
X
}
/
J
-
Spc  
Del  
+
* (asterisk)  
* (asterisk)  
: (colon)  
; (semicolon)  
?
I (letter i)  
8
D
F
L
` (accent)  
_ (underscore)  
N
M
12 - 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To get this 5250 Key / Function  
Press these Keys in this Order  
, (comma)  
Orange  
Orange  
Orange  
Orange  
Orange  
Orange  
Orange  
Shft  
J
' (apostrophe)  
H
B
S
A
G
Q
1
~ (tilde)  
\
|
"
!
!
@
@
#
#
$
$
%
%
^
Orange  
Shft  
W
2
Orange  
Shft  
E
3
Orange  
Shft  
R
4
Blue  
R
T
5
Orange  
Shft  
Orange  
Shft  
Y
6
^
&
&
(
Orange  
Shft  
U
7
Orange  
Shft  
O
9
(
)
Orange  
Shft  
P
)
0 (zero)  
12 - 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
55 key Alphanumeric Keymap - Primary Backspace  
Note: This keypad features a dedicated backspace key.  
The following keymap is used on an MX7 Tecton that is NOT running a Terminal  
Emulator. Terminal emulators use a separate keymap.  
When using a sequence of keys that includes a sticky key, press the sticky key first,  
release it, then press the rest of the key sequence.  
When using a sequence of keys that includes the Orange or Blue keys, press the color  
key first then the rest of the key sequence.  
Tapping the Power key when in any sticky mode (Blue, Orange, Shift, etc.) either turns  
the device On (when Off) or places it in Suspend (when On).  
Alphabetic keys default to lower case letters. Press the Shft key, then the alphabetic key  
for an uppercase letter.  
The diamond 1, F1, F2, F3, F4 and F5 keys can be remapped using the Button panel  
(Start > Settings > Personal > Buttons).  
When the computer boots, the default condition of Caps (or CapsLock) is Off. The Caps  
(or CapsLock) condition can be toggled with Blue plus Tab key sequence  
Del  
BkSp  
.
To get this Key / Function  
Press these Keys in this Order  
Power / Suspend  
Power  
Field Exit (default VK_PAUSE)  
MAP = Mappable  
Blue (MAP)  
Orange (MAP)  
Shift (MAP)  
Diamond #1  
Volume Adjust Mode  
Orange  
Blue  
Scan  
V
Up Arrow / Down Arrow  
Up Arrow / Down Arrow  
Volume Adjust Mode  
Display Backlight Brightness Adjust Mode  
Blue  
Scan  
Toggle Blue Mode  
Toggle Orange Mode  
Toggle Shift Mode  
Alt  
Blue  
Orange  
Shft  
Alt  
Control  
Ctl  
Esc  
Blue  
Alt  
Space  
Spc  
Enter  
Enter  
Scan  
Scan  
CapsLock (Toggle)  
Back Space  
Tab  
Blue  
Tab  
Tab  
Bksp  
Tab  
Back Tab  
Up Arrow  
Down Arrow  
Right Arrow  
Left Arrow  
Insert  
Orange  
Up Arrow  
Down Arrow  
Right Arrow  
Left Arrow  
Blue  
I (letter i)  
12 - 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
To get this Key / Function  
Press these Keys in this Order  
Insert  
Delete  
Home  
End  
Page Up  
Page Down  
F1  
Orange  
Orange  
Shft  
Shft  
Orange  
Orange  
F1  
Ctl  
Spc  
Down Arrow  
Up Arrow  
Up Arrow  
Down Arrow  
F2  
F2  
F3  
F3  
F4  
F4  
F5  
F5  
F6  
Orange  
Orange  
Orange  
Orange  
Orange  
Blue  
Blue  
Blue  
Blue  
Blue  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
A
F1  
F7  
F2  
F8  
F3  
F9  
F4  
F10  
F11  
F12  
F13  
F14  
F15  
F16  
F17  
F18  
F19  
F20  
F21  
F22  
F23  
F24  
a
F5  
F1  
F2  
F3  
F4  
F5  
F1  
F2  
F3  
F4  
F5  
Orange  
Orange  
Orange  
Orange  
F1  
F2  
F3  
F4  
b
B
c
C
d
D
e
E
f
F
g
G
h
H
i
I
j
J
k
K
12 - 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To get this Key / Function  
Press these Keys in this Order  
l
L
m
n
M
N
o
O
p
P
q
Q
r
R
s
S
t
T
u
U
v
V
w
x
W
X
y
Y
z
Z
A
B
C
D
E
F
G
H
I
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
Shft  
A
B
C
D
E
F
G
H
I
J
J
K
L
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
12 - 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To get this Key / Function  
Press these Keys in this Order  
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
0
0
. (period)  
Orange  
Orange  
Blue  
Blue  
Blue  
Blue  
Blue  
Blue  
Blue  
Blue  
Blue  
Blue  
Orange  
Shft  
Bksp  
K
. (period  
<
G
[
Y
]
Z
>
H
=
T
{
W
X
}
/
J
-
Spc  
Bksp  
+
* (asterisk)  
I (letter i)  
* (asterisk)  
8
: (colon)  
Orange  
Orange  
Orange  
Orange  
Orange  
Orange  
Orange  
Orange  
Orange  
Orange  
Orange  
Orange  
Shft  
D
F
L
; (semicolon)  
?
` (accent)  
N
M
J
_ (underscore)  
, (comma)  
' (apostrophe)  
H
B
S
A
G
Q
1
~ (tilde)  
\
|
"
!
!
@
@
#
#
Orange  
Shft  
W
2
Orange  
Shft  
E
3
12 - 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To get this Key / Function  
Press these Keys in this Order  
$
Orange  
Shft  
R
4
$
%
%
^
Blue  
R
T
5
Orange  
Shft  
Orange  
Shft  
Y
6
^
&
&
(
Orange  
Shft  
U
7
Orange  
Shft  
O
9
(
)
Orange  
Shft  
P
)
0 (zero)  
12 - 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
32 key Numeric-Alpha Keymap  
The following keymap is used on an MX7 Tecton that is NOT running a Terminal  
Emulator. Terminal emulators use a separate keymap.  
When using a sequence of keys that require an alpha key, first press the Alph key. Use  
the Shft sticky key or the Caps key sequence (Blue+Tab) for upper case alphabetic  
characters.  
Pressing the Alph key forces “Alpha” mode for the 2,3,4,5,6,7,8, and 9 keys. The 1 and  
0 keys continue to place a 1 and 0 into the text field.  
To create a combination of numbers and letters before pressing Enter, remember to tap  
the Alph key to toggle between Alpha and Numeric mode.  
When using a sequence of keys that do not include the Alph key but does include a  
sticky key, press the sticky key first then the rest of the key sequence.  
The diamond 1, F1, F2, F3, F4 and F5 keys can be remapped using the Button panel  
(Start > Settings > Personal > Buttons).  
Pressing the Power key when in any sticky mode (Blue, Orange, Shift, etc) either turns  
the device On (when Off) or places it in Suspend (when On).  
.
To get this Key / Function  
Press these Keys in this Order  
Power / Suspend  
Power  
Field Exit (default is VK_PAUSE)  
MAP = Mappable  
Blue (MAP)  
Orange  
Blue  
Shft (MAP)  
Shft (MAP)  
Shft (MAP)  
Shft (MAP)  
Shft (MAP)  
Scan  
Diamond #1  
=
Diamond#2  
Default is Mappable  
(
Diamond#2  
Default is Mappable  
!
Orange  
Blue  
Diamond#3  
Default is Mappable  
)
Diamond#3  
Default is Mappable  
Volume Adjust Mode  
Orange  
Blue  
Up Arrow  
Down Arrow  
Display Backlight Brightness  
Adjust Mode  
Scan  
Up Arrow  
Down Arrow  
Toggle Alpha Mode  
Toggle Blue Mode  
Toggle Orange Mode  
Toggle Shift Mode  
Alt Mode  
Alph  
Blue  
Orange  
Shft  
Alt  
Control Mode  
Esc  
Ctrl  
Blue  
Spc  
Alt  
Space  
Enter  
Enter  
Scan  
Blue  
Scan Mode  
CapsLock (Toggle)  
Tab  
12 - 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
To get this Key / Function  
Press these Keys in this Order  
Back Space  
Orange  
Tab  
Spc  
Tab  
Back Tab  
Up Arrow  
Down Arrow  
Right Arrow  
Left Arrow  
Insert  
Delete  
Home  
End  
Orange  
Up Arrow  
Down Arrow  
Blue  
Tab  
Up Arrow  
Down Arrow  
Ctrl  
Blue  
Orange  
Del  
Shft  
Down Arrow  
Up Arrow  
Shft  
Page Up  
Page Down  
F1  
Orange  
Orange  
F1  
Up Arrow  
Down Arrow  
F2  
F2  
F3  
F3  
F4  
F4  
F5  
F5  
F6  
Orange  
Orange  
Orange  
Orange  
Orange  
Blue  
F1  
F2  
F3  
F4  
F5  
F1  
F2  
F3  
F4  
F5  
F1  
F2  
F3  
F4  
F5  
F7  
F8  
F9  
F10  
F11  
F12  
Blue  
F13  
Blue  
F14  
Blue  
F15  
Blue  
F16  
Shft  
F17  
Shft  
F18  
Shft  
F19  
Shft  
F20  
Shft  
F21  
Shft  
Orange  
Orange  
Orange  
Orange  
2
F1  
F2  
F3  
F4  
F22  
Shft  
F23  
Shft  
F24  
Shft  
a
Alpha  
Alpha  
Alpha  
Alpha  
b
22  
c
222  
d
3
12 - 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To get this Key / Function  
Press these Keys in this Order  
e
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Shft  
33  
f
333  
4
g
h
i
44  
444  
5
j
k
55  
l
555  
6
m
n
o
p
q
r
66  
666  
7
77  
777  
7777  
8
s
t
u
v
88  
888  
9
w
x
99  
y
999  
9999  
z
A
B
C
D
E
F
G
H
I
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
2
Shft  
22  
222  
3
Shft  
Shft  
Shft  
33  
333  
4
Shft  
Shft  
Shft  
44  
444  
5
Shft  
J
Shft  
K
L
M
N
O
P
Q
R
S
Shft  
55  
555  
6
Shft  
Shft  
Shft  
66  
666  
7
Shft  
Shft  
Shft  
77  
777  
7777  
Shft  
Shft  
12 - 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To get this Key / Function  
Press these Keys in this Order  
T
Shft  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
Alpha  
8
U
Shft  
88  
V
Shft  
888  
9
W
Shft  
X
Shft  
99  
Y
Shft  
999  
9999  
Z
Shft  
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
0
0
. (period)  
Orange  
Blue  
Blue  
Orange  
Blue  
Orange  
Blue  
Orange  
Blue  
Blue  
Blue  
Blue  
Blue  
Orange  
Shft  
DEL  
<
7
[
2
[
2
]
3
]
3
>
8
=
Diamond#2  
{
4
}
5
/
1
-
Spc  
+
Del  
* (asterisk)  
* (asterisk)  
: (colon)  
; (semicolon)  
?
Diamond#1  
8
Orange  
Blue  
Orange  
Blue  
Orange  
Orange  
Orange  
Blue  
Orange  
0
0
8
` (accent)  
_ (underscore)  
, (comma)  
' (apostrophe)  
~ (tilde)  
\
6
7
6
Alph  
9
1
12 - 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To get this Key / Function  
Press these Keys in this Order  
|
Orange  
Blue  
Alt  
"
Alph  
!
Orange  
Shft  
Diamond#3  
!
1
@
@
#
#
$
$
%
^
Orange  
Shft  
5
2
Orange  
Shft  
4
3
Orange  
Shft  
9
4
Shft  
5
Blue  
Ctrl  
^
Shft  
6
&
(
Shft  
7
Blue  
Diamond#2  
9
(
Shft  
)
Blue  
Diamond#3  
0 (zero)  
)
Shft  
12 - 20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13  
Battery Charger  
Unpacking your Battery Charger  
After you open the shipping carton containing the product, take the following steps:  
Check for damage during shipment. Report damage immediately to the carrier who delivered the carton.  
Make sure the items in the carton match your order.  
Save the shipping container for later storage or shipping.  
Introduction  
The MX7 Tecton Battery Charger is designed to simultaneously charge four rechargeable Lithium Ion (Li-Ion) battery packs. The  
time required for charging is dependent upon the battery pack temperature and conditions.  
The battery charger should be located in an area where it:  
Is well ventilated.  
Is not in high traffic areas.  
Locates or orients the AC cord so that it will not be stepped on, tripped over or subjected to damage or stress.  
Has enough clearance to allow easy access to the power port on the back of the device.  
Is protected from rain, dust, direct sunlight or inclement weather.  
This device is intended for indoor use only and requires an indoor AC power source. The charger is not approved for use in Haz-  
ardous Locations.  
This device cannot charge/recharge coin cell batteries sealed inside the mobile device, if any.  
This chapter is intended to familiarize the user with the safety and operating instructions necessary to use the MX7 Tecton Bat-  
tery Charger (Model MX7390CHARGER, MX7391CHARGER) to charge rechargeable lithium-ion battery packs  
(MX7A380BATT, MX7A381BATT, MX7392BATT, MX7393BATT, MX7A396BATT) .  
This information should be readily available to all users and maintenance personnel using this battery charger.  
Store the charger and batteries when not in use in a cool, dry, protected place.  
13 - 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Cautions and Warnings  
Battery Charger  
There is a risk of explosion if the MX7 Tecton Li-Ion battery in the charging pocket is replaced by an incorrect type. Other  
batteries or battery packs may burst causing injury or property damage.  
Do not insert any other type of Li-Ion battery in the battery charging pocket.  
Do not allow cleaning agents of any kind to contact the battery charging contacts; they may be damaged. If necessary,  
clean them with a soft-bristle, dry brush or compressed air.  
Disconnect the charger from AC power by pulling the plug; not the cord.  
Use care when inserting battery. Do not “slam” or slide the battery into the pocket, this could damage the charger.  
Keep dirt and foreign objects out of the battery pocket. Do not short circuit any of the contacts in the battery pocket, this  
could result in injury or property damage.  
Do not disassemble or perform modifications to the charger. There are no user serviceable components in the charger.  
Lithium-Ion Battery Pack  
Dispose of used Li-Ion batteries according to the instructions for the type of battery.  
When not in use, lay the battery pack contact-side up in a protected environment.  
Do not store the Li-Ion battery pack in direct sunlight or anywhere the battery pack cannot cool down.  
If the Li-Ion battery pack is hot after removal from the MX7 Tecton, allow it to cool at room temperature or in a cool air  
stream before placing it in the charger.  
Do not dispose of Li-Ion batteries into a fire. Burning will generate hazardous vapors and may cause the battery to  
explode. Failure to observe this warning may result in injury from inhalation of vapors or burns from flying debris.  
Do not immerse Li-Ion batteries in water or any other liquid. If batteries are immersed, contact Technical Assistance (page  
Do not disassemble or perform modifications to the battery. There are no user serviceable components in the battery.  
Do not place the Li-Ion battery into a pocket or toolbox with conductive objects (coins, keys, tools, etc.). A Li-Ion battery  
placed on damp ground or grass could be electrically shorted.  
Do not store Li-Ion batteries above 140°F (60°C) for extended periods.  
Failure to observe these warnings could result in injury or damage to the battery from rapid discharge of energy or battery  
overheating.  
Electrolyte Burns. Be careful when handling batteries. If a battery is broken or shows signs of leakage do not attempt to  
charge it. Dispose of it! Lead and Nickel-based cells contain a chemical solution that burns skin, eyes, etc. Leakage from  
cells is the only possible way for such exposure to occur. In this event, rinse the affected area thoroughly with water. If  
the solution contacts the eyes, get immediate medical attention.  
Electrical Burns. Batteries are capable of delivering high currents when accidentally shorted. Accidental shorting can  
occur when contact is made with jewelry, metal surfaces, conductive tools, etc., making the objects very hot. Never place  
a charged battery in a pocket or case with keys, coins, or other metal objects.  
Front View  
1. Front  
2. Battery Charging Pocket  
3. LED Indicator  
4. Power Connection Location  
LED Function Legend  
13 - 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Top View  
1. Battery Charging Pocket  
2. Retaining Clip  
3. Battery Charging Contacts  
13 - 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installation  
Assemble the Power Supply  
Assemble the AC adapter for the MX7 Tecton Battery Charger before connecting it to the charger.  
The AC power supply for the battery charger is shipped with the battery charger. Contact Technical Assistance (page 16-1)  
if there is no AC cable.  
The battery charger power supply is intended for use with the MX7 Tecton battery charger only.  
1. Plug the 3-prong end of the cable into an AC wall outlet.  
2. Firmly press the female end of the power cable into the male connector on the AC power adapter. An LED on the power  
adapter illuminates when AC power is available.  
3. AC power is now being applied to the power adapter.  
Setup  
Place the battery charger on a flat, horizontal, hard surface or fasten securely to a stable surface using the keyhole open-  
ings on the bottom of the battery charger. See Mounting (page 13-5).  
Do not insert battery packs until the battery charger has finished powering up:  
1. Assemble the Power Supply and connect it to an indoor power source (e.g. wall outlet).  
2. Insert the power connector from the power supply into the power outlet at the back of the battery charger.  
3. AC power is now being applied to the battery charger and it begins to power up.  
4. Charge pocket LEDs flash while the battery charger enters and exits the startup check.  
5. When the charge pocket LEDs are not illuminated, the battery charger is ready for use.  
13 - 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Mounting  
The battery charger should be located in an area where it:  
Is well ventilated.  
Is not in high traffic areas.  
Locates or orients the AC cord so that it will not be stepped on, tripped over or subjected to damage or stress.  
Has enough clearance to allow easy access to the power port on the back of the device.  
Is protected from rain, dust, direct sunlight or inclement weather.  
This device is intended for indoor use only and requires an indoor AC power source. The charger is not approved for use in haz-  
ardous locations.  
Place the battery charger on a flat, horizontal, hard surface.  
The battery charger can be mounted to a stable, vertical surface (e.g., wall) using the keyhole openings in the bottom panel of  
the battery charger.  
Note: Footprint is not to scale  
1. Length of battery charger - 11.75 inches (in)/ 29.8 centimeters (cm)  
2. Width of battery charger - 5.25 in / 13.3 cm  
3. Left keyhole center to right keyhole center - 9.8 in / 25 cm  
4. Distance down to keyhole center from back of battery charger - 0.75 in / 1.9 cm  
5. Distance to keyhole center from side of battery charger - 1.1 in / 3.0 cm  
6. Distance to keyhole center from front of battery charger - 4.25 in / 10.8 cm  
Care should be taken, when inserting batteries in a vertical-mounted battery charger, that the battery is secured by the latch in  
the battery charging pocket.  
13 - 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Charging Batteries  
MX7392BATT / MX7393BATT / MX7396BATTERY  
MX7A380BATT / MX7A381BATT  
New batteries should be charged fully before first use. The life and capacity of a Lithium Ion battery pack can vary significantly  
depending on the discharge current and the environment in which it is used.  
When a battery is placed in a charging pocket, the battery charger begins charging the battery. There is a slight delay while the  
charger evaluates the condition of the battery (ambient temperature, remaining charge, etc.) before charging begins.  
As with all batteries, expect to see a reduction in the total number of operations a fully charged battery pack can deliver as it  
ages. When the battery reaches end of life (end-of-life occurs after 500 charge/discharge cycles) it must be replaced.  
Battery packs do not need to be fully discharged between charge cycles.  
While charging, the charger and battery pack will generate enough heat to feel warm. This is normal and does not indicate a  
problem.  
Inserting a Battery into the Charging Pocket  
It is important that battery packs are inserted into the charging pocket correctly. Inserting the battery incorrectly could result  
in damage to the battery pack or the charger.  
Caution! Do not “slam” the battery pack into the charging pocket. Damage may result.  
When preparing the battery pack for insertion into the battery charging pocket, hold the battery with its four charging con-  
tacts in line with the charging contacts in the charging pocket. Aim the retaining catch towards the back of the charger.  
Tilt the front end (without the latch) of the battery pack into the front end of the battery charging pocket, and firmly press the  
other end (with the latch) until it is fully inserted into the battery charging pocket. Push down on the battery pack until the  
retaining clip on the battery catches on the retaining bracket in the pocket.  
Remove the Battery from the Charging Pocket  
Push the latch toward the battery and, grasping the battery and latch firmly, take the battery out of the charging pocket.  
Interpreting the Charging Pocket LEDs  
The status of the charge operation is indicated by the color of the LED for each charging pocket.  
RED Continuous - on any charge pocket  
Continuous red means the battery pack is charging.  
RED FLASHING - on any charge pocket  
Battery pack fault or failure.  
RED FLASHING - on all charge pockets  
Battery charger fault or failure.  
Battery pack fault or failure or a battery charger timeout period expiration.  
GREEN - on any charge pocket  
Continuous green means the battery pack charge is complete - Battery is Ready.  
YELLOW - on any charge pocket  
Continuous yellow / amber means the battery pack temperature is out of range. The charging pocket is in standby mode  
while the pocket waits for the battery pack to warm up or cool down.  
13 - 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
NO LIGHT - on any charge pocket  
No light on a charge pocket means there is no battery pack installed,  
or the battery pack in the pocket is not fully inserted,  
or a defective or damaged battery pack is installed,  
or the charger is defective or damaged. Refer to Battery Charger Help.  
NO LIGHT - on all charge pockets  
No light means there is no AC power available to the battery charger or there is power but there are no batteries in any  
charging bay.  
Battery Charger Help  
The following is intended as an aid in determining whether the battery pack or the charger may be malfunctioning:  
Problem  
Cause  
Solution  
Battery pack does not fit in  
charging pocket.  
Different manufacturer's battery  
pack, or there is an object in the  
charging pocket.  
Check if the battery pack has part number MX-  
7A380BATT / MX7392BATT or a Low Temperature (CS)  
Battery : MX7A381BATT / MX7393BATT / MX7396BAT-  
TERY part number on the label. If not, do not use.  
Remove the object from the charging pocket.  
No battery pack in charger, but Dirt or foreign objects are in the  
any of the LEDs are on. charging pocket.  
Unplug charger from AC supply. Remove any dirt or for-  
eign objects from the charging pocket. See Charger  
continue to remain ON, the charger may be defective.  
Return charger to an authorized service center.  
Charger is plugged into a live Battery pack is not making contact Push the battery pack in firmly until you hear a click as  
outlet, battery pack is inserted, with battery charge terminals in the the battery catch connects with the charger pocket. Do  
but RED LED is OFF and no  
other LEDs are on, or all LEDs  
are off.  
charging pocket.  
not “slam” the battery pack into the charging pocket.  
Charger is plugged into a live Faulty battery pack.  
outlet, battery pack is inserted,  
but RED LED is OFF and no  
other LEDs are on, or all LEDs  
are off.  
Replace battery pack.  
Charger is plugged into a live New battery pack, same result.  
outlet, battery pack is inserted,  
but RED LED is OFF and no  
other LEDs are on, or all LEDs  
are off.  
ment options.  
When you first put a fully  
During the first few minutes, the  
There is nothing wrong with the battery pack or charger.  
charged battery pack in the  
battery charger checks the battery Do not “top off” a fully charged battery pack by repeated-  
charging pocket, the RED LED pack for correct voltage and charge ly placing it in the charging pocket. The battery pack may  
comes on, indicating the bat-  
tery pack is charging.  
state. During this time the LED is  
RED and is continuously ON. After  
charging is complete, the LED is  
GREEN.  
overheat and be damaged.  
LED is flashing RED at any  
pocket.  
Current could not be sourced  
through the battery pack due to  
age, exhaustion or damage to the  
cell(s). The battery pack does not  
communicate with the charger.  
pack replacement options.  
LED is flashing RED at any  
pocket.  
The charger’s timeout period has  
expired.  
Make sure that the battery pack temperature is within  
specification and retry charging. Contact Technical  
Assistance (page 16-1) if problem repeats, for battery  
pack replacement options.  
13 - 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Problem  
Cause  
Solution  
LED is flashing RED at any  
pocket.  
The battery pack voltage has not  
reached 6.0V within 30 minutes and pack replacement options.  
the charger has timed out.  
Solid YELLOW / AMBER LED The battery pack is too hot or too  
when battery pack is inserted cold to charge.  
in the charging pocket.  
Remove battery pack from the charging pocket and allow  
it to adjust to room temperature.  
Note: If the battery pack is left in the charging pocket, it  
will cool down or warm to a temperature upon  
which the charger will begin the charge cycle.  
However, depending on the temperature of the  
battery, it may take 2-3 hours to adjust. The cool-  
down / warm-up of a battery pack is much quicker  
if the battery is not in the charging pocket.  
Charger Cleaning, Storage and Service  
Cleaning  
Unplug the charger from the power source before cleaning or removing debris from charging pockets.  
Use only mild detergent with a slightly damp cloth to clean the outside of the charger. Do not use solvents or flammable  
cleaners. Allow the case to dry fully before using again.  
Do not allow cleaning agents of any kind to contact the charging contacts; they may be damaged. If necessary, clean them  
with a soft-bristle, dry brush or compressed air.  
Storage  
Remove all batteries from the charging bays and disconnect AC power before placing the charger in storage. It should be  
stored in a cool, dry place, protected from weather and airborne debris.  
Battery packs should be kept in a cool, dry place whenever possible. Do not store battery packs in direct sunlight, on a  
metal surface, or anywhere the battery pack cannot cool down. Do not leave the battery pack in a non-operating charger.  
The battery pack may discharge through the charger rather than hold its charge.  
Service  
There are no user serviceable parts in the rechargeable Lithium Ion battery or the charger. Contact Technical Assistance  
(page 16-1) should your charger require service.  
13 - 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Battery Cleaning, Storage and Service  
Cleaning  
The battery pack should not require cleaning unless it has become heavily soiled. Old or damaged batteries should be dis-  
posed of promptly and properly. The best way to dispose of used batteries is to recycle them. Battery recycling facilities  
recover the nickel, lithium or lead from old batteries to manufacture new batteries.  
Use only mild detergent with a slightly damp cloth to clean the outside of the battery. Do not use solvents or flammable  
cleaners. Allow the case to dry fully before using again.  
Do not allow cleaning agents of any kind to contact the charging contacts; they may be damaged. If necessary, clean them  
with a soft-bristle, dry brush or compressed air.  
Storage  
Battery packs should be stored, charging contact side up, in a cool dry place, protected from weather and airborne debris,  
whenever possible.  
Do not store battery packs in direct sunlight, on a metal surface, or anywhere the battery pack cannot cool down.  
Do not leave the battery pack in a non-operating charger. The battery pack may discharge through the charger rather than  
hold its charge.  
Note: Battery packs may leak up to 1 mA current through the battery contacts when left in a non-powered charger pocket.  
Service  
There are no user serviceable parts in the lithium ion battery pack. Contact Technical Assistance (page 16-1) for battery  
disposal and replacement options.  
13 - 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
13 - 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14  
Cradles  
Unpacking your Cradles  
After you open the shipping carton containing the product, take the following steps:  
Check for damage during shipment. Report damage immediately to the carrier who delivered the carton.  
Make sure the items in the carton match your order.  
Save the shipping container for later storage or shipping.  
Communication cables and power cables are ordered separately.  
Overview  
This chapter provides instruction for the end-user, installer or system administrator to follow when setting up or using MX7  
Tecton cradles.  
Three cradles are available:  
A desktop cradle that secures the MX7 Tecton, recharges batteries and enables communications between the MX7 Tecton  
A passive vehicle-mounted cradle that secures the MX7 Tecton and isolates it from shock and vibration. See Using a Passive  
A powered vehicle-mount cradle that secures the MX7 Tecton, isolates it from shock and vibration and recharges the battery.  
MX7 Tecton cradles are not certified for use in hazardous locations.  
The MX7 Tecton must have a main battery installed when it is docked in a cradle. Wireless host/client communications can  
occur whether the cradle is receiving external power or not as wireless functions draw power from the main battery in the MX7  
Tecton.  
MX7 Tecton keypad data entries can be mixed with cradle-tethered scanner bar code data entries while the MX7 Tecton is in a  
powered cradle. Bluetooth device connection and use, while the MX7 Tecton is docked, are managed by the MX7 Tecton  
Bluetooth program, not the cradle.  
The MX7 Tecton can be either On, Off or in Suspend Mode while in the cradle. Special purpose and power cables are available  
from Honeywell.  
Never put the MX7 Tecton into a vehicle mounted assembly until the assembly is securely fastened to the vehicle.  
Preparing the Cradle for Use  
Note: Keep dirt and foreign objects out of the cradle. Do not short circuit any of the charging terminals (pins), as this action could  
result in injury or property damage.  
Place cradles on a stable surface out of the way of:  
inclement weather,  
extremely high concentrations of dust or wind blown debris,  
accidental knocks, bumps or other shocks to the cradle and items in the cradle bays.  
Leave enough space at cable connectors to ensure cables are protected from jostling, tugging or being disconnected by  
passing objects.  
Leave enough space at the back of the cradle for the MX7 Tecton trigger handle.  
In addition to the above, vehicle mounted cradles should be positioned in the vehicle where the cradle:  
is protected from rain and inclement weather,  
does not obstruct the driver's vision or safe vehicle operation,  
can be easily accessed by a user seated in the driver's seat while the vehicle is not in operation.  
14 - 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Tethered Scanners and the MX7 Tecton Cradles  
An MX7 Tecton powered cradle supports tethered scanner attachment. A powered cradle provides 5V power to a tethered  
scanner. The passive vehicle cradle cannot support tethered scanner attachment. There is no software in the cradles.  
Note: The cradle must be powered by an external power source to enable tethered scanner use.  
Note: Pressing the MX7 Tecton Scan button has no effect on tethered bar code scanners connected to a powered cradle.  
Tethered scanners read bar code scans only when the trigger on the tethered scanner is pressed.  
A tethered scanner can be connected to the 9-pin RS232 Serial Interface port on the desktop cradle or to the Serial Interface  
port on the back of the vehicle cradle.  
Bluetooth scanner connection and use, while the MX7 Tecton is docked in a cradle, are managed by the MX7 Tecton Bluetooth  
client, not the cradle.  
MX7 Tecton keypad data entries can be mixed with tethered scanner bar code data entries. Any tethered scanner that decodes  
the bar code internally and outputs an RS232 data stream may be used. It sends the data to the MX7 Tecton in ASCII format.  
Tethered scanners send scanned data to the MX7 Tecton when the MX7 Tecton is in a powered cradle and the tethered scanner  
is connected to the Serial Interface port on the cradle.  
When a tethered scanner is connected to the Serial Interface port on a powered cradle, the MX7 Tecton must be configured as  
follows:  
1. Open the Data Collection Wedge Main tab panel on the MX7 Tecton.  
2. Enable either Device 1, Device 2 or Device 3.  
3. Close the Data Collection Wedge application.  
Maintenance  
There are no serviceable parts in the MX7 Tecton cradles. Do not attempt to open the units.  
If the cradle becomes cracked or broken at any time, it must be taken out of service and replaced. Contact Technical Assistance  
(page 16-1) for a replacement cradle.  
Periodically test a mounted cradle and tighten connections as needed.  
Cleaning  
Do not use paper towels or harsh-chemical-based cleaning fluids since they may result in damage to the surfaces and/or battery  
connectors.  
Use a clean soft cloth to wipe any dirt, moisture or grease from the MX7 Tecton, charging contacts or the cradle. Do not use any  
liquid to clean the cradle, battery pack, MX7 Tecton, or charging terminals (pins). Spray or dampen the cleaning cloth with  
liquids/sprays. If possible, clean only those areas which are soiled.  
Lint/particulates can be removed from the connectors, charging terminals and charging/docking pockets with clean, filtered  
canned air.  
14 - 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Using a Desktop Cradle  
Introduction  
Note: When an external power supply is used to power this cradle, the external power supply should be UL Listed, with LPS  
or Class 2 outputs rated 12V, minimum 2 amps.  
The desktop cradle is available in three configurations:  
1. Without a power supply. A power supply must be ordered separately.  
2. With a power supply and a US power cord.  
3. With a power supply but without a power cord. A country specific power cord must be provided.  
Communications cables for the MX7 Tecton are available separately.  
Quick Start - Desktop Cradle  
The following list outlines, in a general way, the process to follow when preparing the MX7 Tecton desktop cradle for use.  
Refer to the following sections in this document for more details.  
2. Connect the cradle end of the power adapter cable to the Power port on the back of the cradle.  
3. Attach the AC power connector to a dependable power source.  
4. Attach any desired external cabled devices to the ports on the cradle.  
5. The desktop cradle is ready for use.  
Battery Charging in a Desktop Cradle  
The MX7 Tecton main battery recharging is managed by the Power Management settings in the MX7 Tecton. Refer to the  
Power control panel on the MX7 Tecton.  
The spare battery in the spare battery well re-charges with or without an MX7 Tecton in the dock. The spare battery is fully  
charged in approximately four hours.  
The cradle must be receiving power from an external power source before the main battery in the docked MX7 Tecton or  
spare battery pack charging can take place.  
14 - 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Front View  
1. Charging Pocket Adapter Cup  
2. MX7 Tecton Docked LED  
3. Serial Interface Connector  
4. Spare Battery LED  
5. I/O Connector  
6. Table Mounting Hole Guides  
14 - 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Back View  
1. Charging Pocket Adapter Cup  
2. Cradle Connector  
3. Spare Battery Charging Bay  
4. Power Connector  
14 - 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Top View  
1. Power Supply Connector  
2. Spare Battery Charging Bay  
3. Spare Battery Charging Terminals  
4. Spare Battery Latch  
5. Spare Battery  
6. Table Mounting Holes  
7. Cradle Connector  
8. Docking Bay Adapter Cup  
9. Docking Bay Adapter Cup Mounting Hole  
10. Desktop Cradle Label  
11. Serial Interface Connector  
12. I/O Connector  
Desktop Mounting Footprint  
1. Front  
2. Table Mounting Hole Guides  
3. Back  
Bolts, washers, screws, screwdriver or wrench needed when attaching the MX7 Tecton desktop cradle to a protected flat  
surface are not supplied by Honeywell.  
Periodically check the table mounting hardware and re-tighten if necessary. Table mounting hardware can be finger-  
tightened.  
Note: Do not over-tighten the table mounting hardware. If the cradle is cracked, it must be replaced before being placed  
into service. Contact Technical Assistance (page 16-1) for help.  
14 - 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installing and Removing the Docking Bay Adapter Cup  
Equipment Required -- Phillips screwdriver and torquing tool (not supplied by Honeywell). You will need a torquing tool  
capable of torquing up to 6 (+/- .5) in/lb. Install/remove the docking bay adapter cup using a clean, well-lit stable surface.  
The cradle is shipped with the docking bay adapter cup pre-installed. If the MX7 Tecton has a rubber boot, the docking bay  
adapter cup must be removed before the MX7 Tecton is placed in the desktop cradle.  
The cradles can dock an MX7 Tecton with a rubber boot (MX7490BOOT or MX7491BOOT) enclosing/protecting the  
device.  
Before docking an MX7 Tecton without a rubber boot in the cradle, reinstall the docking bay adapter cup.  
Installing  
The adapter cup is installed facing in one direction.  
1. Put the adapter cup in the MX7 Tecton docking bay, aligning the screw hole in the adapter cup with the screw hole  
in the MX7 Tecton docking bay.  
2. Using a torquing screwdriver, insert the screw in the adapter cup screw hole, and torque the screw to 6 in/lbs +/- .5  
in/lbs.  
3. Periodically check the connection of the adapter cup and re-torque if necessary.  
Removing  
1. Remove the adapter cup by unscrewing the single captive screw at the front of the adapter cup.  
2. Place both the adapter cup and the screw in a protected, safe area until needed.  
14 - 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Assemble/Attach the AC Power Adapter  
Note: Connect the cable to the cradle first, then to an AC source.  
The external Power Supply for the cradle is shipped with the cradle. Contact Technical Assistance (page 16-1) if there is no  
AC cable.  
The cradle Power connector is located on the back of the cradle.  
1. Plug the AC power plug into any AC wall outlet with a dependable power source.  
2. Firmly press the adapter end of the power cable into the 3 pin connector on the power adapter.  
3. Firmly press the cradle end of the power cable into the single connector on the back of the cradle.  
4. AC power is now being supplied to the AC power adapter and the cradle.  
14 - 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Connecting Input/Output Cables to the Desktop Cradle  
Note: Route all cables to ensure they are protected from jostling, tugging or being disconnected by passing objects.  
The cradle must be receiving power from an external power source before MX7 Tecton battery charging can begin.  
The serial cable is connected to the port labeled Serial Interface on the left front of the desktop cradle. The serial cable end  
can originate with a tethered scanner, a PC, a printer or another serial device.  
The I/O connector cable is connected to the port (male) labeled MX7 Tecton I/O Port on the right front of the desktop cradle.  
Periodically test the connections for stability and re-tighten if necessary.  
Attaching a Serial Cable  
1. Align the RS232 serial cable end (female) carefully to the Serial Interface port (male) on the left front of the desktop  
cradle.  
2. Press the ends together and finger tighten the screws on either side of the connector.  
3. Test the connection for stability.  
Attaching the Input/Output (I/O) Cable  
1. Squeeze the clips next to the connector attached to the cable to open the catches in the connector assembly.  
2. Firmly press the cable end (female) into the MX7 Tecton I/O Port connector (male) on the front of the cradle.  
3. Release the clips in the connector cable.  
4. Test the connection for stability.  
Cradle LEDs  
When the desktop cradle AC/DC power supply cable begins to supply power to the cradle, the cradle LEDs flash yellow,  
red, green for three seconds then turn off. The cradle is ready for use.  
Docked LED  
When Docked LED is …  
It means ….  
Off  
MX7 Tecton not inserted or no power applied.  
MX7 Tecton docked and power applied.  
Red  
Note: The cradle must be connected to a power source before the LEDs illuminate.  
14 - 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Spare Battery LED  
When Spare LED is …  
It means ….  
Off  
Battery pack not inserted or no power applied.  
Battery pack fully charged.  
Green  
Red  
Battery pack charging.  
Yellow / Amber  
Flashing Red  
Battery pack temperature out of range.  
Battery pack fault or failure.  
Note: The cradle must be connected to AC power before the LEDs illuminate. Spare battery charging does not require  
an MX7 Tecton be docked in the docking bay.  
MX7 Tecton System Status LED Status when Docked  
The MX7 Tecton System Status LED is located above the Scan button.  
When the MX7 Tecton LED is . . .  
The Status is . . .  
Comment  
Blinking Red  
Power Fail  
Replace the main battery with a fully charged main  
battery.  
Or  
Connect the MX7 Tecton to external AC power to  
allow the internal charger to charge the main battery  
e.g., dock in a powered cradle.  
Steady Red  
Main Battery Low  
Low Battery Warning. Replace the main battery with  
a fully charged main battery. Or dock the MX7  
Tecton in a powered cradle.  
Blinking Green  
No Color  
Display Off  
Good  
No user intervention required.  
No user intervention required.  
Docking and Undocking the MX7 Tecton  
When the MX7 Tecton is in Suspend Mode it wakes up when it is docked in a powered cradle. There is no change in mode  
state settings or behavior when the MX7 Tecton is docked in a cradle without a power source.  
MX7 Tecton mode states while the MX7 Tecton is in a powered cradle e.g., suspend, resume, display backlight, etc., are  
managed by the MX7 Tecton OS Power settings.  
The MX7 Tecton is inserted into the charging pocket with the keypad facing forward. If the cradle is not permanently  
attached to the work surface, stabilize the cradle with one hand while inserting or removing the MX7 Tecton with the other  
hand.  
Dock the MX7 Tecton  
Remove any cables attached to the base of the MX7 Tecton.  
Carefully press the MX7 Tecton straight down into the docking bay until the multi-pin connector at the base of the MX7  
Tecton clicks into place with the multi-pin charging/communication connector at the bottom of the docking bay. The  
MX7 Tecton cradle is designed to secure the MX7 Tecton facing forward.  
The cradle's Docked LED illuminates.  
Undock the MX7 Tecton  
Remove the MX7 Tecton from the cradle by pulling it straight up and out of the docking bay. If necessary, stabilize the  
cradle with one hand while the other hand removes the MX7 Tecton.  
The cradle's Docked LED turns Off.  
14 - 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Inserting / Removing a Spare Battery from the Desktop Cradle  
Prerequisites: The steps outlined in Assemble/Attach the AC Power Adapter (page 14-8) have been completed and the  
cradle has a dependable power source. The cradle has been bolted to a stable surface, if desired.  
Note: Do not drop or slam the spare battery into the charging pocket. Damage may result.  
A fully depleted spare battery recharges in approximately four hours in the MX7 Tecton powered cradle. Charging time may  
take longer if a tethered scanner, connected to the Serial port and drawing power from the cradle, is used.  
The spare battery well is molded in the shape of the MX7 Tecton main battery. The spare battery can be inserted in the  
battery well in only one direction. When there is an MX7 Tecton, with or without a handle, docked in the cradle, a spare  
battery can still be inserted in the charging bay. You do not need to undock the MX7 Tecton before inserting or removing a  
spare battery in the cradle.  
Stabilize the cradle with one hand when inserting/removing the spare battery, if necessary.  
Inserting a Spare Battery  
1. Hold the battery with the charging terminals facing down, toward the charging pocket.  
2. Tilt the end (without the latch) of the spare battery pack into the upper end of the battery charging pocket, and firmly  
press down on the other end (with the latch) until the battery is fully inserted into the battery well.  
3. Push down on the spare battery until the catch clicks into place, securing the spare battery in the battery bay. This  
will ensure the charging contacts on the spare battery connect with the re-charging contacts in the battery bay.  
The Spare charging bay LED illuminates indicating the battery is properly seated in the charging bay.  
Removing a Spare Battery  
A green Spare battery LED signifies the spare battery is charged.  
Remove the Spare battery by pushing the latch toward the battery and pulling the Spare battery up, with a hinging  
motion, and out of the charging bay. The Spare charging bay LED turns Off.  
14 - 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Desktop Cradle Help  
The following is intended as an aid in determining whether the MX7 Tecton battery pack or the cradle battery charger may  
be malfunctioning.  
Problem  
Cause  
Solution  
Battery pack does not fit  
in battery well.  
Different manufacturer's battery pack,  
or there is an object in the battery well.  
Check if the battery pack is part number  
MX7A380BATT / MX7392BATT or a Low  
Temperature (CS) Battery : MX7A381BATT /  
MX7393BATT / MX7396BATTERY. If not, do not  
use.  
Remove the object from the battery well.  
No battery pack in spare  
battery charging well,  
but the charging LED is  
on.  
Dirt or foreign objects are in the battery  
well.  
Unplug cradle from outlet. Remove any dirt or  
foreign objects from battery well.  
If the LED continues to stay ON, the cradle may  
be defective. Return charger to an authorized  
service center.  
Cradle is plugged into a  
live outlet, battery pack  
is inserted, but RED  
LED is OFF and no  
other LEDs are on, or all  
LEDs are off.  
Battery pack is not making contact with  
charging terminals in the battery well.  
Push battery pack in firmly. Do not “slam” the  
battery pack into the battery well.  
Faulty battery pack.  
Replace battery pack.  
New battery pack, same result.  
replacement options.  
When you first put a  
fully charged battery  
pack in the battery well,  
the RED LED comes  
on, indicating the  
battery pack is  
During the first few minutes, the  
charger checks the battery pack for  
correct voltage and charge state.  
During this time the LED is RED and is  
continuously ON. After charging is  
complete, the LED is GREEN.  
There is nothing wrong with the battery pack or  
charging pocket.  
charging.  
LED is flashing RED at  
any station. LED is  
flashing RED at any  
station.  
Current could not be sourced through  
the battery pack due to age,  
exhaustion or damage to the cell(s).  
Or  
battery pack replacement options.  
The battery pack does not  
communicate with the charger.  
The charger’s timeout period has  
expired.  
Make sure that the battery pack temperature is  
within specification and retry charging. If problem  
1) for battery pack replacement options.  
Solid YELLOW LED  
when battery pack is  
inserted in the cradle.  
The battery pack is too hot or too cold  
to charge.  
Remove battery pack from the cradle and allow it  
to adjust to room temperature.  
If the battery pack is left in the cradle, it will cool  
down or warm to a temperature upon which the  
cradle will begin the charge cycle. However,  
depending on the temperature of the MX7 Tecton  
battery, it may take 2-3 hours to adjust. The  
battery pack can cool down faster if the battery is  
not in the battery well.  
MX7 Tecton docked in  
cradle but cannot work  
with accessory cables  
connected to cradle.  
MX7 Tecton not fully seated in cradle  
Foreign objects inside docking bay or  
cable connectors  
Reseat the MX7 Tecton fully into the docking bay.  
Remove the foreign objects and reseat the MX7  
Tecton into the docking bay.  
14 - 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Problem  
Cause  
Solution  
MX7 Tecton docked in  
cradle but Docked LED  
does not light up.  
MX7 Tecton not fully docked.  
Power supply not connected.  
Check the docking bay is clear of foreign objects  
and reseat the MX7 Tecton fully into the docking  
bay.  
Check that power is applied to the Power Jack at  
the rear of the MX7 Tecton Desktop Cradle.  
14 - 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using a Passive Vehicle Cradle  
Introduction  
Note: The protective boot or carrying case (if used) must be removed before inserting the MX7 Tecton into a securely  
mounted passive vehicle cradle.  
The MX7 Tecton passive vehicle cradle consists of:  
Cradle bracket  
U-bracket  
2 knobs  
Hook and loop fabric to secure the MX7 Tecton  
An optional RAM assembly consists of:  
RAM ball base for vehicle mount  
RAM arm  
RAM base to attach U-bracket  
4 each: bolts, nuts and washers  
The installer must supply hardware to attach either the U-bracket or the RAM ball base to the vehicle.  
Communications cables for the MX7 Tecton are available separately.  
Wireless communication is available as long as the MX7 Tecton has sufficient energy in the main battery pack and a clear  
signal path. The passive vehicle cradle is lined with strips of hook-and-loop fabric to ensure a snug fit between the MX7  
Tecton and the inside of the cradle. The cradle can secure the MX7 Tecton with or without a trigger or handstrap. The MX7  
Tecton passive vehicle cradle does not have power, MX7 Tecton serial or input/output connectors.  
There are two mounting options for the cradle:  
Quick Start  
The following list outlines, in a general way, the process to follow when preparing the MX7 Tecton passive vehicle cradle for  
use. Refer to the following sections for more details.  
1. Attach the RAM bracket or U-bracket mounting device to the vehicle.  
2. Attach the MX7 Tecton passive cradle to the vehicle mounted bracket using the Angle Adjust knobs.  
3. Adjust the cradle to the best viewing angle using the Angle Adjust knobs.  
14 - 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Components  
U-Bracket Footprint  
The image below is not to scale.  
RAM Assembly Components  
Mount the cradle U-bracket to the upper RAM ball assembly with the bolts, washers and nuts supplied by Honeywell.  
Qty 4 – Hex Cap 1/4-20 x 3/4 bolts  
Qty 4 – 1/4 flat washer  
Qty 4 – 1/4-20 nylon insert lock nuts  
14 - 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
RAM Assembly Footprint  
Installing the Cradle U-Bracket  
Note: Honeywell does not supply the bolts or washers needed when mounting the cradle assembly to the vehicle chassis.  
Use bolts with a maximum 10/32” (0.3125) diameter.  
1. Attach the U-Bracket to the vehicle, making sure it does not impede safe operation of the vehicle.  
2. Attach the Passive Cradle to the U-Bracket using the Angle Adjust knobs.  
3. Use both knobs to loosen and tighten the cradle to the U-bracket while determining the best viewing angle. The passive  
vehicle mounted cradle is ready for use.  
Periodically test the passive mounting device and tighten bolts and/or knob as needed. If the cradle becomes cracked or  
warped it must be replaced before the cradle is put back in service.  
14 - 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installing the RAM Bracket  
1. MX7 Tecton  
2. Angle Adjust Knobs  
3. Passive Cradle  
4. U-Bracket  
5. Mounting Hex Bolt  
6. Upper RAM Ball Assembly  
7. Arm  
8. Thumbscrew  
9. Lower RAM Ball Assembly  
1. Attach the lower RAM ball assembly to the vehicle, making sure it does not impede safe operation of the vehicle.  
2. Fasten the upper RAM ball assembly to the base of the U-bracket using the supplied bolts, washers and screws.  
3. Loosen the turnscrew on the RAM arm, place the lower socket over the vehicle mount RAM ball, then the other arm  
socket over the RAM ball on the U-bracket.  
4. Tighten the arm turnscrew until the U-bracket is secured to the RAM arm and the vehicle.  
5. Attach the Passive Cradle to the U-Bracket using the Angle Adjust knobs.  
6. Use both knobs to loosen and tighten the cradle to the U-bracket while determining the best viewing angle. The passive  
vehicle mounted cradle is ready for use.  
Periodically test the mounting device and tighten bolts and/or knob as needed. If the cradle becomes cracked or warped it  
must be replaced.  
14 - 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Using a Powered Vehicle Cradle  
Introduction  
The MX7 Tecton vehicle mount cradle uses one of the following power supply options:  
A power cable for 12V vehicles  
DC/DC power supply for non-12V vehicles  
AC/DC power supply with US power cord  
AC/DC power supply, requires country specific C14 type power cord.  
The available RAM mount options include:  
RAM ball base for vehicle  
RAM ball base for MX7 Tecton  
2 Screws (to attach RAM ball to MX7 Tecton)  
RAM arm  
The installer must supply hardware to attach the RAM ball base to the vehicle.  
Communications cables for the MX7 Tecton are available separately.  
Quick Start  
The following list outlines, in a general way, the process to follow when preparing the MX7 Tecton powered vehicle  
mounted cradle for use. Refer to the following sections for more details.  
1. Attach the vehicle mounting assembly to the vehicle.  
2. Attach the cradle to the vehicle mounting assembly.  
3. Secure the MX7 Tecton in the mounted vehicle cradle.  
4. Adjust the MX7 Tecton to the best viewing angle.  
5. Connect peripheral cables.  
6. Secure the DC/DC or 12 VDC power connector from the vehicle mounted power supply to the Power port.  
7. Secure all cables in strain relief cable clamps.  
The MX7 Tecton in the powered vehicle mounted assembly is ready for use.  
14 - 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Components  
Before installation begins, verify you have the applicable vehicle mounting bracket assembly components necessary for  
your mount type.  
Front View  
1. Retainer  
2. Retainer Springs  
3. Handle Opening  
4. Vehicle Cradle Adapter Cup  
5. Charging Pocket  
6. MX7 Tecton Docked LED  
14 - 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Back View  
1. Retainer  
2. Retainer Springs  
3. Handle Opening  
4. RAM Bracket Mounting Locations  
5. Strain Relief Cable Clamps  
6. Serial Interface Port  
7. Power Connector  
8. MX7 Tecton I/O Port  
14 - 20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing or Removing Vehicle Cradle Adapter Cup and Top Adapter  
Equipment Required -- Phillips screwdriver and torquing tool (not supplied by Honeywell). You will need a torquing tool  
capable of torquing up to 6 in/lb (+/- .5 in/lb) for the cradle adapter cup.  
Install or remove the adapter on a clean, well-lit stable surface. The vehicle cradle is shipped with the cradle Adapter Cup  
and Retainer Insert pre-installed.  
The MX7 Tecton cradle charging pocket, without a cradle adapter cup and top adapter, is designed for an MX7 Tecton with  
a rubber boot (MX7490BOOT or MX7491BOOT) enclosing/protecting the MX7 Tecton.  
Before docking an MX7 Tecton without a rubber boot in the vehicle cradle, install the vehicle cradle Adapter Cup and  
Retainer Cap Insert.  
14 - 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing the Adapter  
Charging Pocket Adapter Cup  
The adapter cup is installed facing in one direction.  
1. Slip the adapter cup into the cradle charging pocket, aligning the screw hole in the adapter cup with the screw hole  
in the charging bay.  
2. Using a torquing screwdriver, insert the screw in the adapter cup screw hole, and torque the screw to 6 in/lbs +/- .5  
in/lbs.  
Retainer Insert  
The Retainer Insert has three tabs.  
14 - 22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
1. Lay the flat side of the Retainer Insert against the underside of the Retainer cap, show below.  
2. Slide the Retainer Insert back tab into the slot at the back of the Retainer.  
3. Fasten the Retainer Insert to the Retainer cap using screws and the pre-drilled holes in the angled tabs (one on  
each side).  
4. Fasten the Retainer Insert with two screws (the screws do not require a torquing tool).  
Periodically check the connection of the adapter cup and re-torque if necessary. Periodically check the Retainer Insert  
connection and re-tighten if necessary.  
Removing the Adapter Assembly  
1. Remove the adapter cup by unscrewing the single captive screw at the front of the adapter cup.  
2. Remove the Retainer Cap Insert by unscrewing the two screws holding it to the Retainer.  
3. Slide the tab out of the slot in the back of the Retainer assembly.  
Place the screws, adapter cups and the Retainer Cap Insert in a protected, safe place until needed.  
If the adapter cup or retainer insert are cracked or broken, they must be replaced before a powered vehicle cradle, with an  
adapter cup and Retainer Cap Insert, is placed into service.  
14 - 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
RAM Bracket Mounting  
RAM Bracket Assembly mounting holes are on the back of the cradle. The mounting screws fit in Pim nuts and are  
automatically secured.  
The number of RAM balls attached to the back of the vehicle mount cradle are dependent upon the desired RAM mount  
configuration.  
The figure shown below is an example only.  
RAM ball mounting screws are included in the mounting kit.  
RAM Bracket Mounting Points  
The figure shown below is an example only.  
1. Trigger Handle opening  
2. Upper mounting points  
3. Lower mounting points  
14 - 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Vehicle Cradle RAM Ball Assembly  
1. Fasten the RAM ball with the circular mounting base (shown in the middle in above image) to the vehicle.  
2. Fasten the RAM ball with the rectangular mounting base (shown on the right in above image) to the back of the  
vehicle cradle.  
3. Loosen the knob on the squeeze arm (shown on the left in above image).  
4. Place either RAM ball opening in the squeeze arm over the vehicle mounted RAM ball.  
5. Place the remaining RAM ball opening over the vehicle cradle mounted RAM ball.  
6. Tighten the knob on the squeeze arm until the vehicle cradle is secured to the vehicle.  
7. Adjust the position of the secured vehicle cradle by slightly loosening the squeeze arm knob, rotating the cradle and  
then re-tightening the squeeze arm knob.  
Periodically test the mounting device and re-tighten bolts, RAM balls and/or squeeze arm adjustment knob as needed.  
RAM Circular Base Footprint  
Bolts, washers and nuts for mounting the RAM ball to the vehicle are supplied by Honeywell:  
Qty 4 – Hex Cap 1/4-20 x 3/4 bolts  
Qty 4 – 1/4 flat washer  
Qty 4 – 1/4-20 nylon insert lock nuts  
Note: Mount to the most rigid surface available.  
14 - 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
DC/DC Power Supply Installation, Screws on Top of lid  
For use with Honeywell power supplies  
9000301PWRSPLY – Power Supply, 18-60VDC with cable  
9000302PWRSPLY – Power Supply, 60-110VDC with cable:  
Shown With Lid Attached  
Lid is secured with screws on the top of lid.  
Shown With Lid Removed  
Input and output connector blocks under lid.  
Two positive (+), negative (-) and ground (  
connections per terminal block  
)
If your DC to DC power supply does not look like the image above, see DC/DC Power Supply Installation, Screws on Side  
of Lid (page 14-29) for installation instruction.  
Connecting Electrical Cables to Power Sources  
The DC to DC power supply is used to provide vehicle power to the MX7 Tecton when placed in a DC powered vehicle  
cradle.  
Specifications for Electrical Supply  
Input Voltage  
Output Voltage  
Power  
Always observe input voltage range specified on the DC to DC power supply.  
12 VDC 10%  
60 W  
Fuse  
5 A (slow blow fuse). Fuses are USER SUPPLIED  
Note: Refer to the Wiring Schematic that follows for wiring colors and connections.  
Caution:  
For proper and safe installation, the input power cable must be connected to a fused circuit on the  
vehicle. This fused circuit requires a five Amp maximum time delay (slow blow) high interrupting rating  
fuse. If the supply connection is made directly to the battery, the fuse should be installed in the positive  
lead within 5 inches of the battery positive (+) terminal. Note: For North America, a UL Listed fuse is to  
be used.  
!
Caution:  
Usage in areas where moisture can affect the power supply connections should be avoided. The power  
supply should be mounted in a dry location within the vehicle or placed in a suitable protective  
enclosure.  
!
Caution:  
For installation by trained service personnel only.  
!
Warning:  
Risk of ignition or explosion. Explosive gas mixture may be vented from battery. Work only in well  
ventilated area. Avoid creating arcs and sparks at battery terminals.  
!
14 - 26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Wiring Schematic  
Connecting Vehicle Electrical Supply  
1. The vehicle cradle must be empty.  
2. Begin by connecting the power cable to the vehicle cradle. Work from this connection with the last connection being  
to the vehicle’s power source.  
3. Route the cable from the cradle to the DC to DC power supply.  
4. Cut the cable to length and strip the wire ends. Route the power cable the shortest way possible. The cable is rated  
for a maximum temperature of 105°C (221°F). When routing this cable it should be protected from physical damage  
and from surfaces that might exceed this temperature. Do not expose the cable to chemicals or oil that may cause  
the wiring insulation to deteriorate. Always route the cable so that it does not interfere with safe operation and  
maintenance of the vehicle.  
5. Remove the lid from the DC to DC power supply by removing only the screws on the top of the lid.  
6. Attach the stripped wire ends to the output side of the DC to DC power supply.  
7. Attach the stripped wire ends to the input side of the DC to DC power supply.  
8. The input and output blocks each have two + plus and two – minus connectors. Either connector in the block can be  
used to connect the matching polarity wire. The input and output blocks also each have two chassis ground  
connections. When connecting the cradle to vehicle power, use one chassis ground connector in each block.  
14 - 27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
9. Wire colors depend on the type of device attached. Please refer to the Wiring Schematic for wire colors.  
10. Use the looms and wire ties to secure all wiring as shown above, then reattach the lid.  
11. Connect the DC to DC power supply to the vehicle’s electrical system as directed below:.  
Caution: For battery powered vehicles:  
VIN+ is connected to battery positive.  
ViN- must be connected to battery negative.  
!
must be connected to the vehicle chassis ground.  
For internal combustion engine powered vehicles:  
VIN+ is connected to battery positive.  
ViN- is connected to battery negative.  
is connected to the vehicle chassis ground, which can also be battery negative.  
12. While observing the fuse requirements shown in Specifications for Electrical Supply, connect the power cable as  
close as possible to the actual battery terminals of the vehicle. When available, always connect to unswitched  
terminals in the vehicle fuse panel, after providing proper fusing.  
ATTENTION: For uninterrupted power, electrical supply connections should not be made at any point after  
the ignition switch of the vehicle.  
13. Use proper electrical and mechanical fastening means for terminating the cable. Properly sized “crimp” type  
electrical terminals are an accepted method of termination. Select electrical connectors sized for use with 18AWG  
(1mm2) conductors.  
14. Provide mechanical support for the cable by securing it to the vehicle structure at approximately one foot intervals,  
taking care not to over tighten and pinch conductors or penetrate the outer cable jacket.  
14 - 28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DC/DC Power Supply Installation, Screws on Side of Lid  
For use with  
9000311PWRSPLY – Power Supply, 9-60VDC, 60W  
9000313PWRSPLY – Power Supply, 50-150VDC, 60W:  
Shown With Lid Attached  
Shown With Lid Removed  
Lid is secured with screws on the side of lid.  
Input and output connector blocks under lid.  
One positive (Vin+), negative (Vin-) and ground  
(
) connection in input block.  
One positive (Vo+) and negative (Vo-) connection in  
output block.  
If your DC/DC power supply does not look like the image above, see DC/DC Power Supply Installation, Screws on Top of  
lid (page 14-26) for installation instruction.  
Connecting Electrical Cables to Power Sources  
The DC/DC power supply is used to provide vehicle power to the MX9 when it is placed in a DC powered vehicle  
cradle.  
Specifications for Electrical Supply  
Input Voltage  
Output Voltage  
Fuse  
Always observe input voltage range specified for the DC/DC power supply.  
13.5 VDC 10%  
5 A (slow blow fuse). Fuses are USER SUPPLIED  
Note: Refer to the Wiring Schematic that follows for wiring colors and connections.  
Caution: For proper and safe installation, the input power cable must be connected to a fused circuit on the  
vehicle. This fused circuit requires a five Amp maximum time delay (slow blow) high interrupting rating  
!
fuse. If the supply connection is made directly to the battery, the fuse should be installed in the positive  
lead within 5 inches of the battery positive (+) terminal. Note: For North America, a UL Listed fuse is to be  
used.  
Caution: Usage in areas where moisture can affect the power supply connections should be avoided. The power  
supply should be mounted in a dry location within the vehicle or placed in a suitable protective enclosure.  
!
Caution: For installation by trained service personnel only.  
!
Warning: Risk of ignition or explosion. Explosive gas mixture may be vented from battery. Work only in well  
ventilated area. Avoid creating arcs and sparks at battery terminals.  
!
14 - 29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Wiring Schematic  
Connecting to Vehicle Power  
The vehicle cradle must be empty. The last connection must be to the vehicle power source.  
1. Connect the power cable to the vehicle cradle.  
2. Route the cable from the cradle to the DC/DC power supply.  
3. Cut the cable to length and strip the wire ends.  
4. Route the power cable the shortest way possible. The cable is rated for a maximum temperature of 105°C (221°F).  
When routing this cable it should be protected from physical damage and from surfaces that might exceed this  
temperature. Do not expose the cable to chemicals or oil that may cause the wiring insulation to deteriorate. Always  
route the cable so that it does not interfere with safe operation and maintenance of the vehicle.  
5. Remove the lid from the DC/DC power supply by removing only the screws on the side of the lid.  
6. Attach the stripped wire ends to the output side of the DC/DC power supply  
.
Note: The input block has VIN+, VIN- and GND terminals. The output block has VO+ and VO- terminals.  
7. Connect the ground wire from the cradle to the GND terminal on the input side of the DC/DC power supply.  
14 - 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
8. Route the wiring from the DC/DC power supply to the vehicle’s electrical system. Do not connect to vehicle  
power at this time.  
9. Strip the wire ends and connect to the input side of the DC/DC power supply.  
10. Use looms and wire ties to secure all wiring as shown.  
11. Reattach the cover with the screws.  
12. Connect the DC/DC power supply to the vehicle’s electrical system as directed below:  
Caution:  
For battery powered vehicles:  
VIN+ is connected to battery positive.  
ViN- must be connected to battery negative.  
!
must be connected to the vehicle chassis ground.  
For internal combustion engine powered vehicles:  
VIN+ is connected to battery positive.  
ViN- is connected to battery negative.  
is connected to the vehicle chassis ground, which can also be battery negative.  
13. While observing the fuse requirements specified above, connect the power cable as close as possible to the  
actual battery terminals of the vehicle. When available, always connect to unswitched terminals in the vehicle fuse  
panel, after providing proper fusing.  
ATTENTION: For uninterrupted power, electrical supply connections should not be made at any point after  
the ignition switch of the vehicle.  
14. Use proper electrical and mechanical fastening means for terminating the cable. Properly sized “crimp” type  
electrical terminals are an accepted method of termination. Select electrical connectors sized for use with 18AWG  
2
(1mm ) conductors.  
15. Provide mechanical support for the cable by securing it to the vehicle structure at approximately one foot intervals,  
taking care not to over tighten and pinch conductors or penetrate the outer cable jacket.  
14 - 31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vehicle 12V Bare Wire Adapter  
Part Number: 9000A079CBL12ML3  
Caution: For proper and safe installation, the input power cable must be connected to a fused circuit on the vehicle.  
This fused circuit requires a ten Amp maximum time delay (slow blow) high interrupting rating fuse. If the  
supply connection is made directly to the battery, the fuse should be installed in the positive lead within 5  
inches of the battery positive (+) terminal. Note: For North America, a UL Listed fuse is to be used.  
!
Caution: For installation by trained service personnel only.  
!
Vehicle Cable Connection Cable (Fuse Not Shown)  
1. To Vehicle Battery  
2. To Vehicle Mounted Device  
3. Green (GND)  
4. Brown (DC+)  
5. Blue (DC-)  
6. 12 VDC  
Connecting the Power Cable to the Vehicle  
1. Vehicle Electrical System  
2. 10 Amp Slow Blow Fuse  
3. DC +  
4. DC -  
5. Vehicle Chassis  
6. Brown  
7. Blue  
8. Green  
Note: Correct electrical polarity is required for safe and proper installation. The cradle will not power on or function if  
the cable is connected with the polarity reversed. See the following figure titled “Vehicle Connection Wiring Color  
Codes” for additional wire color-coding specifics.  
Connecting Vehicle 12 VDC Supply  
1. The power cable must be UNPLUGGED from the MX7 Tecton vehicle cradle.  
2. While observing the fuse requirements specified above, connect the power cable as close as possible to the actual  
battery terminals of the vehicle. When available, always connect to unswitched terminals in the vehicle fuse panel,  
after providing proper fusing.  
3. ATTENTION: For uninterrupted power, electrical supply connections should not be made at any point after the  
ignition switch of the vehicle.  
4. Route the power cable the shortest way possible. The cable is rated for a maximum temperature of 105°C (221°F).  
When routing this cable it should be protected from physical damage and from surfaces that might exceed this  
temperature. Do not expose the cable to chemicals or oil that may cause the wiring insulation to deteriorate.  
5. Always route the cable so that it does not interfere with safe operation and maintenance of the vehicle.  
14 - 32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
6. Use proper electrical and mechanical fastening means for terminating the cable. Properly sized “crimp” type  
electrical terminals are an accepted method of termination. Select electrical connectors sized for use with 18AWG  
(1mm2) conductors.  
7. Wiring color codes for Honeywell supplied DC input power cabling:  
Vehicle Supply  
Wire Color  
+12 VDC  
DC +  
DC -  
GND  
Brown  
Blue  
Return  
Vehicle Chassis  
Green  
8. Provide mechanical support for the cable by securing it to the vehicle structure at approximately one foot intervals,  
taking care not to over tighten and pinch conductors or penetrate outer cable jacket.  
9. Refer to the following sections to complete the power connection to the MX7 Tecton vehicle cradle.  
Connecting Power Supply to Vehicle Cradle  
Note: When an external power supply is used to power this cradle, the external power supply should be UL Listed, with  
LPS or Class 2 outputs rated 12V, minimum 2 Amps.  
The power cable connector is L-shaped. The long end of the L (the cable) will be facing up towards the middle strain  
relief cable clamp. The Power port is on the back of the cradle.  
1. Align the connector pins to the vehicle cradle Power connector; firmly pushing the connector into the Power port.  
2. Tighten the nut of the plug clockwise until the power cable is securely fastened.  
3. Secure the cable to the cradle with the strain relief cable clamps, see Vehicle Cradle Strain Relief Cable Clamps  
4. The power LED on the MX7 Tecton illuminates when it is receiving external power and the MX7 Tecton is docked.  
Attaching a Serial or I/O Connector  
The serial cable is connected to the port labeled Serial Interface on the back of the vehicle cradle.  
The serial cable can originate with a tethered scanner, a PC, a printer or another serial device.  
The I/O connector cable is connected to the port (male) labeled MX7 Tecton I/O Port on the back of the vehicle cradle.  
Periodically test the connections for stability and re-tighten if necessary.  
Serial Port  
1. Align the RS232 serial cable end (female) carefully to the Serial Interface port (male) at the back of the cradle.  
2. Firmly press the ends together and finger tighten the screws on either side of the connector. Test the connection for  
stability.  
3. Secure the cable to the cradle with one of the strain relief cable clamps on the back of the vehicle cradle.  
I/O Port  
1. Squeeze the clips next to the connector attached to the I/O cable to open the catches in the connector assembly.  
2. Firmly press the cable end (female) into the I/O Port connector (male) at the back of the cradle. Release the clips in  
the connector cable. Test the connection for stability.  
3. Secure the cable to the cradle with one of the strain relief cable clamps on the back of the vehicle cradle.  
14 - 33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Vehicle Cradle Strain Relief Cable Clamps  
Equipment Required: Phillips screwdriver (not supplied by Honeywell).  
There are three strain relief cable clamps secured to the back of the vehicle cradle, located above the ports for the  
Serial Interface, Power and MX7 I/O connections.  
1. Remove the strain relief cable clamp from the back of the cradle by turning the screw counterclockwise. Put the  
screw aside in a safe location.  
2. Slide the strain relief clamp over the cable.  
3. Using a Phillips screwdriver and the screw that was removed, refasten the clamp holding the cable to the vehicle  
cradle. Do not stretch the cable. Leave enough slack in the cable to allow the cable to be connected and  
disconnected from the MX7 Tecton easily when needed.  
4. Continue in this manner until all cables are secured to the back of the vehicle cradle.  
Vehicle Cradle LED  
The cradle LED is located at the front center of the cradle.  
When Cradle LED is …  
It means ….  
MX7 Tecton is docked. Cradle does not have power.  
MX7 Tecton is not docked. Cradle may have power. Check  
the power connector at the back of the cradle.  
Off  
MX7 Tecton is docked and external power is connected.  
Red  
14 - 34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Docking the MX7 Tecton in a Powered Vehicle Cradle  
Note: Do not put the MX7 Tecton into the vehicle cradle until the cradle is securely fastened to the vehicle. Always put the  
handle through the Handle Opening first or damage to the scanner aperture may occur.  
1. The MX7 Tecton is inserted into the cradle by pressing the base of the MX7 Tecton down into the cradle pocket until the  
connector at the base of the MX7 Tecton clicks into place with the charging connector at the bottom of the docking well.  
2. If the cradle is connected to a power source, the Docked LED illuminates.  
3. Firmly press the MX7 Tecton backward until the Retainer snaps forward, its latches catching on the front of the MX7  
Tecton, securing it in the cradle.  
Do not slam the MX7 Tecton into the cradle pocket. Damage to the cradle and MX7 Tecton components may occur. If the  
vehicle cradle or MX7 Tecton is damaged, it must be removed from service and repaired before placing it into service again.  
14 - 35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Removing the MX7 Tecton from a Powered Vehicle Cradle  
1. Push the top of the Retainer up and back until the MX7 Tecton is released from the Retainer latches and the charging  
pocket swings forward.  
2. Pull the MX7 Tecton up and out of the vehicle cradle pocket, disconnecting the MX7 Tecton from the charge/  
communication port at the base of the docking bay. The Docked LED turns off.  
Powered Vehicle Cradle Help  
The following is intended as an aid in determining whether the MX7 Tecton or the vehicle mounted cradle may be  
malfunctioning.  
Problem  
Cause  
Solution  
MX7 Tecton docked in  
cradle but cannot work  
with accessory cables  
connected to cradle.  
MX7 Tecton not fully seated in cradle.  
Reseat the MX7 Tecton fully into the docking bay.  
There are foreign objects inside  
docking bay or cable connectors  
Remove the foreign objects and reseat the MX7  
Tecton in the docking bay.  
MX7 Tecton docked in  
cradle but Docked LED  
does not light up.  
MX7 Tecton not fully docked.  
Check the docking bay is clear of foreign objects  
and reseat the MX7 Tecton fully into the docking  
bay.  
Power supply not connected.  
Check that power is connected to the Power Port  
at the rear of the cradle.  
14 - 36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
15  
Technical Specifications  
MX7 Tecton Hardware  
Processor  
Marvell PXA-320 CPU operating at 806 MHz. Turbo mode switching is supported. 32 bit CPU (with on-  
chip cache)  
Memory  
DRAM: 256 MB DDRAM | 256MB NAND Flash  
One SD Memory card slot for Expansion Memory : Options: 1GB, 4GB  
Microsoft® Windows® Mobile® 6.5  
Mass Storage  
Operating System  
Radio Modules  
Scanner options  
802.11 a/b/g radio / Bluetooth  
Integrated.  
No Scanner  
Symbol SE1524ER Lorax  
Symbol SE955I (Short Range)  
Symbol SE955E (Base Laser)  
Hand Held Products 5300 2D Imager  
Honeywell Laser Scanner, N43XX  
Honeywell Laser Scanner, N73XX  
Display  
Transmissive Color LCD. Touch screen. Customer Configurable Display. Backlighting. Indoor readable.  
Type - LCD – Active Transmissive Color / LED Backlight  
Resolution - 320 (Vertical) x 240 (Horizontal) pixels  
Size - 1/4 VGA portrait  
Diagonal Viewing Area - 3.5 in (8.9cm)  
Dot Pitch - 0.22mm  
Dot Size - 0.20mm x 0.20mm  
Color Scale - Reflective – 256 colors  
External Connec-  
tors / Interface  
RS232 COM1 mini D serial port.  
20 Position “D” (female) Connector. Provides cabled connection to external devices such as an audio  
headset, printer, USB/power connection, RS232/power connection.  
Main Battery  
Standard: Li-Ion battery pack 7.4V 2200mAh.In-Unit and External Re-Chargeable  
Cold Storage: Li-Ion battery pack 7.4V 1250mAh.In-Unit and External Re-Chargeable  
Backup Power  
2.5V Super-capacitor (Super-cap). No backup “battery” is used.  
MX7 Tecton Dimensions and Weight  
Dimension  
Length  
8.8” | 22.3 cm  
Width at Display  
Width at handgrip  
3.4” | 8.6 cm  
2.8” | 7.1 cm  
Depth at Scanner  
Depth at Battery  
2” | 5.1 cm  
1.7” | 4.3 cm  
Weight  
Unit with network card, battery, SE1524ER scanner and handle  
1.6 lbs (26.1 oz) | 740g  
1.4 lbs (22.6 oz) | 640g  
4.3 oz | 122g  
Unit with network card, battery, SE1524ER scanner and handstrap  
Battery  
Handle  
4 oz | 110g  
Network Card  
SD Flash Card  
0.35 oz | 9.9g  
1 oz | 28g  
15 - 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
MX7 Tecton Environmental Specifications  
Operating Temperature  
Storage Temperature  
ESD  
14°F to 122°F (-10°C to 50°C)  
-4°F to 158°F (-20°C to 70°C)  
8 KV air, 4kV direct contact  
-30°C to 60°C  
Freezer Operating Temperature  
Operating Humidity  
Water and Dust  
Up to 90% non-condensing at 104°F (40°C)  
IEC 60529 compliant to IP65  
Based on MIL Std 810D  
Vibration  
MX7 Tecton Network Card Specifications  
Summit 802.11 a/b/g SDIO 2.4/5.0GHz  
Wireless Frequencies  
2.4 to 2.4897 GHz IEEE 802.11b / 802.11g DSSS OFDM  
5.0GHz IEEE 802.11a DSSS OFDM  
1, 2, 5.5, 6, 9, 11, 12, 18, 24, 36, 48, 54 Mbps  
64 mW (18dBm)  
RF Data Rates  
RF Power Level  
Channels  
FCC: 1-11, 36, 40 ,44, 48, 149, 153, 157, 161  
ETSI: 1-13, 36, 40, 44 ,48  
Operating Temperature  
Storage Temperature  
Connectivity  
Same as MX7 Tecton Operating Temperature.  
Same as MX7 Tecton Storage Temperature.  
TCP/IP, Ethernet, ODI  
Diversity  
Yes  
Bluetooth  
Connection  
No more than 32.80 feet (10 meters) line of sight  
2.402 – 2.480 GHz  
Operating Frequency  
Bluetooth Version  
2.1 + EDR  
MX7 Tecton AC/DC Wall Adapter  
Input Power Switch  
Power “ON” Indicator  
Input Fusing  
None  
None  
Thermal Fuse  
Input Voltage  
100VAC min – 240 VAC max  
50 - 60 Hz  
Input Frequency  
Input Connector  
Output Connector  
North American wall plug, no ground  
AC wall adapter has a 5.5mm barrel connector. This connects to the cables which  
transition power to the 20 pin D connector.  
Output Voltage  
Output Current  
+12V, regulated  
0 Amps min, 1.25 Amps max  
15 - 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Operating Temperature  
32 F to 100° F / -0° C to 40° C  
The AC Power Adapter is only intended for use in a 25°C (77°F) maximum ambient  
temperature environment.  
Storage Temperature  
Humidity  
-40° F to 180° F / -40° C to 80° C  
Operates in a relative humidity of 5 – 95% (non-condensing)  
Desktop Cradle  
Weight  
18 oz / 500 grams  
Dimensions  
Temperature  
Operating  
Charging  
Storage  
H 3.5 in x W 4.25 in x L 7.5 in  
32° F to 104° F / 0° C to 40° C (charger On, no charging in progress)  
50° F to 104° F / 10° C to 40° C (spare battery charger is charging)  
-4° F to 158° F / -20° C to 70° C  
Humidity  
IEC 60529  
Ports  
5% to 90% (non-condensing) at 104° F / 40° C  
Compliant to IP40  
Power, MX7 Tecton Input/Output and serial port  
Serial Port  
The connector is industry-standard RS232 and is a PC/AT standard 9-pin D male connector.  
Note: Tethered scanners must be connected to powered cradles.  
Pin  
Signal  
DCD  
Description  
1
Data Carrier Detect  
Received Data – Input  
Transmitted Data – Output  
Data Terminal Ready  
Signal/Power Ground  
Data Set Ready  
2
3
4
5
6
7
8
9
RXD  
TXD  
DTR  
GND  
DSR  
RTS  
Request to Send  
CTS  
Clear To Send  
RI or Power  
+5 VDC sourced by the Cradle  
Note: Pin 9 of this port is connected to +5 VDC and only approved Honeywell cables are to be used for communication  
between the cradle and external devices.  
15 - 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Vehicle Mounted Cradle  
Weight  
2 lbs. 15.2 oz / 1.34 kg  
Dimensions  
Height 12.5 in. (31.8 cm)  
Width 6.0 in. (15 cm)  
Depth 5.0 in. (13 cm)  
Operating Temperature  
Storage Temperature  
Humidity  
14° F to 122° F ( -10° C to 50° C)  
-4° F to 158° F (-20° C to 70° C)  
5% to 90% (non-condensing) at 104° F / 40° C  
Serial Port  
The connector is industry-standard RS232 and is a PC/AT standard 9-pin D male connector.  
Note: Tethered scanners must be connected to powered cradles.  
Pin  
Signal  
DCD  
Description  
1
Data Carrier Detect  
Received Data – Input  
Transmitted Data – Output  
Data Terminal Ready  
Signal/Power Ground  
Data Set Ready  
2
3
4
5
6
7
8
9
RXD  
TXD  
DTR  
GND  
DSR  
RTS  
Request to Send  
CTS  
Clear To Send  
RI or Power  
+5 VDC sourced by the Cradle  
Note: Pin 9 of this port is connected to +5 VDC and only approved Honeywell cables are to be used for communication  
between the cradle and external devices.  
15 - 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Power Connector Port  
Note: When an external power supply is used to power these products, the external power supply should be UL Listed, with  
LPS or Class 2 outputs rated 12V, minimum 2 Amps.  
Pin  
Signal  
Wire Color  
Green  
1
Ground (CG)  
Return (-)  
+12V (+)  
2
3
Blue  
Brown  
The Power connector is located on the back of the vehicle cradle.  
Battery Charger  
Battery: MX7 Tecton Li-Ion 7.4V 2.2Ah battery with a 500 charge/discharge life cycle.  
Electrical  
Note: Battery packs may leak up to 1mA current through the battery contacts when left in a non-powered battery charger  
charging pocket.  
Parameter  
Minimum  
100 VAC  
47Hz  
Maximum  
240VAC  
63Hz  
Note  
Power Supply Input Voltage (V AC-IN)  
Power Supply Input Frequency (freq)  
Auto-switching  
Temperature  
Function  
Minimum  
0°C (32°F)  
0°C (32°F)  
Maximum  
Note  
Operating  
+40°C / (104°F)  
+40°C / (104°F)  
Battery Pack Charging  
Battery packs will not begin charging when their inter-  
nal temperature is outside this range.  
Storage  
-20°C (-4°F)  
+70°C / (160°F)  
Unit is off.  
Dimensions  
Category  
Weight  
Dimension  
1.75 lbs / .79 kg  
12.25” / 31.1 cm  
5.25” / 13.3 cm  
Length  
Width  
Height  
1.5” / 4 cm  
Plug Type  
IEC320 (3 prong, grounded)  
15 - 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
15 - 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16  
Customer Support  
Technical Assistance  
If you need assistance installing or troubleshooting your device, please contact us by using one of the methods below:  
Our Knowledge Base provides thousands of immediate solutions. If the Knowledge Base cannot help, our Technical Support  
Portal (see below) provides an easy way to report your problem or ask your question.  
Technical Support Portal: www.hsmsupportportal.com  
The Technical Support Portal not only allows you to report your problem, but it also provides immediate solutions to your techni-  
cal issues by searching our Knowledge Base. With the Portal, you can submit and track your questions online and send and  
receive attachments.  
You can contact our technical support team directly by filling out our online support form. Enter your contact details and the  
description of the question/problem.  
For our latest contact information, please check our website at the link above.  
Product Service and Repair  
Honeywell International Inc. provides service for all of its products through service centers throughout the world. To obtain war-  
ranty or non-warranty service, please visit www.honeywellaidc.com and select Support > Contact Service and Repair to see  
your region’s instructions on how to obtain a Return Material Authorization number (RMA #). You should do this prior to return-  
ing the product.  
Limited Warranty  
Honeywell International Inc. (“HII”) warrants its products to be free from defects in materials and workmanship and to conform to  
HII’s published specifications applicable to the products purchased at the time of shipment. This warranty does not cover any HII  
product which is (i) improperly installed or used; (ii) damaged by accident or negligence, including failure to follow the proper  
maintenance, service, and cleaning schedule; or (iii) damaged as a result of (A) modification or alteration by the purchaser or  
other party, (B) excessive voltage or current supplied to or drawn from the interface connections, (C) static electricity or electro-  
static discharge, (D) operation under conditions beyond the specified operating parameters, or (E) repair or service of the prod-  
uct by anyone other than HII or its authorized representatives.  
This warranty shall extend from the time of shipment for the duration published by HII for the product at the time of purchase  
(“Warranty Period”). Any defective product must be returned (at purchaser’s expense) during the Warranty Period to HII factory  
or authorized service center for inspection. No product will be accepted by HII without a Return Materials Authorization, which  
may be obtained by contacting HII. In the event that the product is returned to HII or its authorized service center within the War-  
ranty Period and HII determines to its satisfaction that the product is defective due to defects in materials or workmanship, HII,  
at its sole option, will either repair or replace the product without charge, except for return shipping to HII.  
EXCEPT AS MAY BE OTHERWISE PROVIDED BY APPLICABLE LAW, THE FOREGOING WARRANTY IS IN LIEU OF ALL  
OTHER COVENANTS OR WARRANTIES, EITHER EXPRESSED OR IMPLIED, ORAL OR WRITTEN, INCLUDING, WITHOUT  
LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, OR  
NON-INFRINGEMENT.  
HII’S RESPONSIBILITY AND PURCHASER’S EXCLUSIVE REMEDY UNDER THIS WARRANTY IS LIMITED TO THE  
REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT WITH NEW OR REFURBISHED PARTS. IN NO EVENT  
SHALL HII BE LIABLE FOR INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, AND, IN NO EVENT, SHALL ANY  
LIABILITY OF HII ARISING IN CONNECTION WITH ANY PRODUCT SOLD HEREUNDER (WHETHER SUCH LIABILITY  
ARISES FROM A CLAIM BASED ON CONTRACT, WARRANTY, TORT, OR OTHERWISE) EXCEED THE ACTUAL AMOUNT  
PAID TO HII FOR THE PRODUCT. THESE LIMITATIONS ON LIABILITY SHALL REMAIN IN FULL FORCE AND EFFECT  
EVEN WHEN HII MAY HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH INJURIES, LOSSES, OR DAMAGES. SOME  
STATES, PROVINCES, OR COUNTRIES DO NOT ALLOW THE EXCLUSION OR LIMITATIONS OF INCIDENTAL OR CONSE-  
QUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.  
16 - 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
All provisions of this Limited Warranty are separate and severable, which means that if any provision is held invalid and unen-  
forceable, such determination shall not affect the validity of enforceability of the other provisions hereof. Use of any peripherals  
not provided by the manufacturer may result in damage not covered by this warranty. This includes but is not limited to: cables,  
power supplies, cradles, and docking stations. HII extends these warranties only to the first end-users of the products. These  
warranties are non-transferable.  
The duration of the limited warranty for the MX7 Tecton is 1 year.  
The duration of the limited warranty for the MX7 Tecton Desktop Cradle is 1 year.  
The duration of the limited warranty for the MX7 Tecton Vehicle Cradle is 1 year.  
The duration of the limited warranty for the MX7 Tecton Passive Vehicle Cradle is 1 year.  
The duration of the limited warranty for the MX7 Tecton Battery Charger is 1 year.  
The duration of the limited warranty for the MX7 Tecton 2200mAh Li-Ion and 1250mAh Li-Ion Battery is 6 months.  
The duration of the limited warranty for the MX7 Tecton AC power supply and cables is 1 year.  
The duration of the limited warranty for the MX7 Tecton DC-DC Converter and cable is 1 year.  
The duration of the limited warranty for the MX7 Tecton cables (USB, Serial, Communication, Power) is 1 year.  
The duration of the limited warranty for the MX7 Tecton fabric accessories (e.g., belt, case, holster) is 90 days.  
The duration of the limited warranty for the MX7 Tecton headset is 1 year.  
16 - 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Back Cvr - 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Honeywell Scanning & Mobility  
9680 Old Bailes Road  
Fort Mill, SC 29707  
TECTON-WM-UG Rev A  
8/14  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Baby Swing 1481 User Manual
Greenheck Fan Ventilation Hood PN 471755 User Manual
Grizzly Lathe G1495 User Manual
Harbor Freight Tools Paint Sprayer 45211 User Manual
Harman Kardon DVD Player DVD22B User Manual
Hasbro Baby Toy 4930 User Manual
Hotpoint Microwave Oven EDC51 User Manual
Hunter Fan Fan 21623 User Manual
Hyundai Car Video System B90A B91A User Manual
ICP DAS USA Network Card LinCon 8000 User Manual