R
Isle Royale
Non-Catalytic, Top-load, Wood Heater
Owner’s Manual
Installation and Operation
Portland
Oregon USA
Tested and
Listed by
O-T L
C
US
OMNI-Test Laboratories, Inc.
Models:
823-0170 - MBK
823-0290 - PMH
CAUTION
DO NOT DISCARD THIS MANUAL
•
Read, understand and
follow these instructions
for safe installation and
operation.
•
Leave this manual with
party responsible for
use and operation.
•
Important operating
and maintenance
instructions included.
WARNING
WARNING
If the information in these
instructions is not followed
exactly, a fire may result causing
property damage, personal injury,
or death.
HOT SURFACES!
Glass and other surfaces are
hot during operation AND
cool down.
Hot glass will cause burns.
• Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
•
•
•
•
Do not touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room
as fireplace.
• Do not overfire - If heater or chimney
connector glows, you are overfiring.
Overfiring will void your warranty.
•
Alert children and adults to hazards of high
temperatures.
• Comply with all minimum clearances to
combustibles as specified. Failure to comply
may cause house fire.
High temperatures may ignite clothing or other
flammable materials.
•
Keep clothing, furniture, draperies and other
flammable materials away.
Installation and service of this appliance should
be performed by qualified personnel. Hearth &
Home Technologies recommends NFI certified
professionals, or technicians supervised by an
NFI certified professional.
WARNING
Fire Risk.
For use with solid wood fuel only.
Other fuels may overfire and generate
poisonous gases (i.e. carbon monoxide).
November 22, 2011
250-5763E
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
Safety Alert Key:
•
•
•
•
DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.
WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.
CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE: Indicates practices which may cause damage to the fireplace or to property.
TABLE OF CONTENTS
Section 1: Listing and Code Approvals
A. Appliance Certifications ......................4
B. Mobile Home Approved ......................4
C. Glass Specifications............................4
D. BTU & Efficiency Specifications..........4
Section 8: Operating Instructions
A. Overfiring Your Appliance...................21
B. Wood Selection & Storage..................21-22
C. Burning Process..................................22-23
D. Combustible / Non-Combustile
Materials .............................................23
E. Air Controls .........................................23
F. Operating the Top Loading Option......24
G. Heat Output Settings...........................24
H. Burn Rates..........................................24
I. Building A Fire.....................................25
J. Blower Operating Instructions.............26
K. Opacity (Smoke) .................................26
L. Frequently Asked Questions...............26
M. Clear Space ........................................26
Section 2: Getting Started
A. Design, Installation & Location
Considerations....................................5
B. Fire Safety ..........................................5
C. Negative Pressure..............................6
D. Flue Draft Considerations...................7
E. Venting Systems.................................7
F. Tools and Supplies Needed................7
G. Inspect Appliance & Components
and Pre-Burn Check List.....................7
H. Typical Stove System .........................8
Section 9: Maintaining & Servicing Appliance
A. General Maintenance & Cleaning.......27-28
B. Appliance Inspection - Routine ...........29
C. Firebrick Inspection & Replacement ...29
D. Glass Replacement.............................29
E. Quick Reference Maintenance Guide.30
Section 3: Dimensions & Clearances
A. Appliance Dimensions ........................9
B. Clearances to Combustibles...............10
Section 4: Installation Consideration
A. Hearth Requirements .........................11
B. Reversible Flue Collar........................12
C. Outside Air..........................................13
D. Optional Blower Installation ................13
Section 10: Troubleshooting........................31
Section 11: Reference Material
A. Exploded Drawings.............................32
B. Service Parts & Accessories...............33-36
C. Service & Maintenance Log................37
D. Warranty Policy...................................38-39
E. Contact Information.............................40
Section 5: Chimney Requirements
A. Venting Components..........................14
B. Chimney Systems...............................14-17
C. Installing Chimney Components .........17
D. Chimney Termination Requirements ..18
E. 2-10-3 Rule..........................................18
Section 6: Mobile Home...............................19
Section 7: Appliance Set-Up
A. Door Handle Assembly.......................20
B. Blower Speed Adjustment ..................20
Page 3
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
Listing and Code Approvals
1
D. BTU & Efficiency Specifications
A. Appliance Certification
Isle Royale
Model:
2.9 grams per hour
76.5%
EPA Certified:
Efficiency:
Laboratory:
Report No & Date:
Type:
OMNI Test Laboratories, Inc.
061-S-18-2
11,500 to 46,000
BTU Output:
Listed Room Heater, Solid Fuel Type
2,040 to 3,500 sq ft
depending on climate zone
Heating Capacity:
Standard:
UL1482, UL737, ULC S627-93
and (UM) 84-HUD, Mobile Home
Approved.
6 inches
Vent Size:
3.0 cubic feet
22 inches
Cord Wood
480 lbs
Firebox Size:
Max Wood Length:
Fuel:
Shipping Weight:
NOTE: This installation must conform with local codes. In the
absence of local codes you must comply with the UL1482, UL737,
(UM) 84-HUD and NPFA211 in the U.S.A. and the ULC S627-93
and CAN/CSA-B365 Installation Codes in Canada.
WARNING
The Quadra-Fire Isle Royale Wood Stove meets the U.S.
Environmental Protection Agency’s 1990 particulate emis-
sion standards.
Fire Risk.
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be
voided by, the following actions:
B. Mobile Home Approved
•
•
•
Installation and use of any damaged appliance.
Modification of the appliance.
• This appliance is approved for mobile home installa-
tions when not installed in a sleeping room and when
an outside combustion air inlet is provided.
Installation other than as instructed by Hearth & Home
Technologies.
•
•
•
•
Installation and/or use of any component part not
approved by Hearth & Home Technologies.
• The structural integrity of the mobile home floor, ceil-
ing, and walls must be maintained.
Operating appliance without fully assembling all
components.
• The appliance must be properly grounded to the frame
of the mobile home with #8 copper ground wire, and
use only listed double-wall connector pipe.
Operating appliance without legs attached (if supplied
with unit).
Do NOT Overfire - If appliance or chimney connector
glows, you are overfiring.
• Outside Air Kit, part 831-1780 must be installed in a
mobile home installation.
Any such action that may cause a fire hazard.
C. Glass Specifications
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage.
For assistance or additional information, consult a qualified
installer, service agency or your dealer.
This stove is equipped with 5mm ceramic glass. Replace
glass only with 5mm ceramic glass. Please contact your
dealer for replacement glass.
Quadra-Fire is a registered trademark of Hearth & Home
Technologies.
NOTE: Hearth & Home Technologies, manufacturer of
this appliance, reserves the right to alter its products,
their specifications and/or price without notice.
Page 4
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
Getting Started
2
B. Fire Safety
A
. Design, Installation & Location Considerations
Consideration must be given to:
To provide reasonable fire safety, the following should be
given serious consideration:
•
•
•
•
Safety
Convenience
Traffic flow
Chimney and chimney connector required
1. Install at least one smoke detector on each floor of
your home to ensure your safety. They should be
located away from the heating appliance and close
to the sleeping areas. Follow the smoke detector
manufacturer’s placement and installation instructions,
and be sure to maintain regularly.
It is a good idea to plan your installation on paper, using exact
measurements for clearances and floor protection, before
actually beginning the installation. If you are not using an
existing chimney, place the appliance where there will be a
clear passage for a factory-built listed chimney through the
ceiling and roof.
2. A conveniently located Class A fire extinguisher to
contend with small fires resulting from burning embers.
3. A practiced evacuation plan, consisting of at least two
escape routes.
We recommend that a qualified building inspector and your
insurance company representative review your plans before
and after installation
4. A plan to deal with a chimney fire as follows:
In the event of a chimney fire:
If this appliance is in an area where children may be near it
is recommended that you purchase a decorative barrier to go
in front of the appliance. Remember to always keep children
away while it is operating and do not let anyone operate
this appliance unless they are familiar with these operating
instructions.
a
Evacuate the house immediately
b. Notify fire department
WARNING
Fire Risk.
CAUTION
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be
voided by, the following actions:
Check building codes prior to installation.
•
•
•
Installation and use of any damaged appliance.
•
Installation MUST comply with local, regional, state and
national codes and regulations.
Modification of the appliance.
Installation other than as instructed by Hearth & Home
Technologies.
•
Consult insurance carrier, local building, fire officials or
authorities having jurisdiction about restrictions, installation
inspection, and permits.
•
•
•
•
Installation and/or use of any component part not
approved by Hearth & Home Technologies.
Operating appliance without fully assembling all
components.
Operating appliance without legs attached (if supplied
with unit).
WARNING
Do NOT Overfire - If appliance or chimney connector
glows, you are overfiring.
Asphyxiation Risk.
• DO NOT CONNECT THIS UNIT TO A CHIM-
NEY FLUE SERVICING ANOTHER APPLI-
ANCE.
Any such action that may cause a fire hazard.
•
DO NOT CONNECT TO ANY AIR DISTRIBU-
TION DUCT OR SYSTEM.
WARNING
May allow flue gases to enter the house.
Fire Risk.
•
Do not operate appliance before reading and
understanding operating instructions.
•
Failure to operate appliance properly may
cause a house fire.
Page 5
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
C. Negative Pressure
To minimize the affects of negative air pressure the following
must be considered:
Draft is the pressure difference needed to vent appliances
successfully. Considerations for successful draft include:
•
Install the outside air kit. Install the intake on the
side of the house towards prevailing winds during the
heating season.
•
•
Preventing negative pressure
Location of appliance and chimney
•
•
•
•
Ensure adequate outdoor air is supplied for combus-
tion appliances and exhaust equipment.
Negative pressure results from the imbalance of air avail-
able for the stove to operate properly. Causes for this imbal-
ance include:
Ensure furnace and air conditioning return vents are
not located in the immediate vicinity of the appliance,
•
•
•
Exhaust fans (kitchen, bath) etc.)
Range hoods
Avoid installing the appliance near doors, walkways
or small isolated spaces.
Combustion air requirements for furnaces, water
heaters and other combustion appliances
Recessed lighting should be of “sealed can” design;
attic hatches weather stripped or sealed; and attic
mounted ductwork and air handler joints and seams
taped or sealed.
•
•
Clothes dryers
Location of return-air vents to furnace or air condi-
tioning
•
•
Imbalances of HVAC air handling system
Upper level air leaks
WARNING
Asphyxiation Risk.
•
•
•
Recessed lighting
Attic hatch opening
Duct leaks
• Negative pressure can cause spillage of
combustion fumes, soot and carbon mon-
oxide.
• Appliance needs to draft properly for
safety.
Recommended Location:
• Above peak
• Inside heated space
Recommended Location:
• Above peak
Marginal Location:
•
Wind loading possible
Marginal Location:
• Below peak
Location NOT recommended:
• Not the highest point of the roof
• Wind loading possible
Location NOT recommended:
• Too close to tree
• Below adjacent structure
• Lower roof line
• Avoid outside wall
Recommended:
• Insulated exterior chase
in cooler climates
Windward
Leeward
Multi-level Roofs
Recommended:
Outside Air Intake
on windward side
NOT recommended:
Outside Air Intake
on leeward side
Figure 6.1
Page 6
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
F. Tools And Supplies Needed
D. Flue Draft Considerations
Location of the appliance and chimney will affect perfor-
mance. As shown in Figure 6.1 on page 6 the chimney
should:
Before beginning the installation be sure that the following
tools and building supplies are available.
•
Be installed through the warm space enclosed by the
building envelope. This helps to produce more draft,
especially during lighting and die down of the fire.
Framing Material
Hi-Temp Caulking Material
Gloves
Reciprocating saw
Pliers
Hammer
Framing Square
Electric Drill & Bits (1/4”)
Safety Glasses
1/2 in. - 3/4 in. length, #6 or
#8 self drilling screws (need 3
per pipe section connection)
Phillips Head Screwdriver
Flat Blade Screwdriver
Plumb Line
Level
Tape Measure
•
•
Penetrate the highest part of the roof. This minimizes
the affects of wind turbulence and down drafts.
Consider the appliance location in order to avoid
floor and ceiling attic joists and rafters.
Exterior conditions such as roof line, surrounding trees,
prevailing winds and nearby hills can influence stove
performance. Your local dealer is the expert in your geographic
area and can usually make suggestions or discover solutions
that will easily correct your flue problem.
G. Inspect Appliance & Components and
Pre-Burn Check List
T
o be sure that your appliance burns properly, the chimney
draft (static pressure) should be approximately -.04 inch water
column (W.C.) during a low burn and -.10 inch W.C. during a
high burn, measured 6 inches (152mm) above the top of the
appliance after one hour of operation at each burn setting.
1.
2.
Place the appliance in a location near the final
installation area and follow the procedures below:
Open the appliance and remove all the parts and
articles packed inside the Component Pack. Inspect
all the parts and glass for shipping damage. Contact
your dealer if any irregularities are noticed.
NOTE: These are guidelines only, and may vary somewhat
for individual installations.
3.
4.
5.
6.
7.
All safety warnings have been read and followed.
This Owner’s Manual has been read.
Floor protection requirements have been met.
Venting is properly installed.
E. Venting Systems
The venting system consists of a chimney connector (also
known as stove pipe) and a chimney. These get extremely
hot during use. Temperatures inside the chimney may
exceed 2000°F (1100°C) in the event of a creosote fire. To
protect against the possibility of a house fire, the chimney
connector and chimney must be properly installed and
maintained. An approved thimble must be used when a
connection is made through a combustible wall to achimney.
Achimney support package must be used when a connection
is made through the ceiling to a prefabricated chimney.
These accessories are absolutely necessary to provide
safe clearances to combustible wall and ceiling material.
Follow venting manufacturer’s clearances when installing
venting system.
The proper clearances from the appliance and
chimney to combustible materials have been met.
8.
The masonry chimney is inspected by a professional
and is clean, or the factory built metal chimney is
installed according to the manufacturer’s instruc-
tions and clearances.
9.
The chimney meets the required minimum height.
All labels have been removed from the glass door.
10.
11.
A power outlet is available nearby if installing
optional blower assembly.
WARNING
WARNING
Fire Risk.
Asphyxiation Risk.
Inspect appliance and components for damage.
Damaged parts may impair safe operation.
• DO NOT CONNECT THIS UNIT TO A CHIM-
NEY FLUE SERVICING ANOTHER APPLI-
ANCE.
•
•
•
Do NOT install damaged components.
Do NOT install incomplete components.
Do NOT install substitute components.
•
DO NOT CONNECT TO ANY AIR DISTRIBU-
TION DUCT OR SYSTEM.
Report damaged parts to dealer.
May allow flue gases to enter the house.
Page 7
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
Spark Arrestor Cap
Concrete Cap
H. Typical Stove Systems
Fireclay Flue Liner
With Air Space
Stove system with masonry chimney
consists of:
Rafter
• Stove
Flashing
Eave
• Chimney Connector (stove pipe)
• Thimble
1 in (25mm) Clearance
With Firestop
Ceiling Joist
• Masonry Chimney
• Hearth Pad Floor Protection
Combustible Wall
Thimble,
12 in (305mm)
Of Brick
Sheathing
Outside Air Rear Vent
Outside Air
Termination Cap
Floor
Protector
Airtight
Cleanout Door
Figure 8.1 Masonry Chimney
Stove system with prefabricated
metal chimney consists of:
Listed Termination Cap
Storm Collar
Flashing
Listed Termination Cap
• Stove
•
Chimney Connector
(stove pipe)
Roof Brace (if required)
• Thimble (for exterior
chimney)
Storm Collar
Flashing
Listed Chimney
• Firestops
• Insulations Shields
• Storm Collar and Flashing
• Termination Cap
Ceiling Support
Trim Collar on
Inside Wall
Listed Chimney
Insulated " T "
Chimney
Connector
• Hearth Pad Floor Protec-
tion
Chimney
Connector
Wall Support
Thimble
Floor
Protector
Floor
Protector
Figure 8.2 Exterior Prefabricated Chimney
Figure 8.3 Interior Prefabricated
Chimney
Page 8
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
Dimensions and Clearances
3
A. Appliance Dimensions
29" (737mm)
NOTE: Flue Collar size is 6 inch
(152mm) diameter (ID)
30" (762mm)
28-3/4" (730mm)
Figure 9.1 - Front View
22-3/4" (578mm)
16-3/4"
(425mm)
C
L
30"
(762mm)
26-7/16"
(570mm)
8-1/4"
(210mm)
16-1/2"
(419mm)
24-5/8" (625mm)
Figure 9.2 - Side View
Page 9
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
B. Clearances To Combustibles (UL And ULC)
C
A
B
H
8 in. max
D
J
Ceiling
G
J*
C
L
E
F
I
26-7/16 in.
(672mm)
I**
F
E
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS In Inches & (Millimeters)
NOTE: “A”, “C” and “F” Dimensions are to the inside diameter of the flue collar.
A
C
I
B
E
F
D
G
H
FOR TOP VENT INSTALLATIONS:
SINGLE WALL PIPE
18 (457)
18 (457)
16 (406)
53 (1346)
53 (1346)
28 (711)
12 (305)
22 (558)
6 (153)
33 (838)
29 (737)
16 (406)
22 (558)
18 (457)
15 (381)
13 (333)
DOUBLE WALL PIPE
14 (356)
14 (356)
INSTALLATION: ALCOVE Six inch (6") (152mm) diameter listed Double Wall air insulated connector pipe with UL 103 HT listed
factory-built Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor). Maximum depth of Alcove
shall be no more than 48 inch(1220mm). Please refer to the clearances below for minimum Alcove height requirements to top of unit.
18 (457)
53 (1346)
N/A
14 (356)
29 (737)
N/A
14 (356)
18 (457)
13 (333)
DOUBLE WALL PIPE
FOR REAR VENT INSTALLATIO
NS:
IN A MASONRY FIREPLACE OR THROUGH THE WALL: Six inch (6") (152mm) diameter listed double wall air insulated
connector pipe with UL 103HT listed factory-built Class "A" chimney, or a masonry chimney. (Mobile Home must be
equipped with a spark arrestor). Additonal specifications include a maximum 8 inch (203mm) deep mantel without
heat shield and the following clearances.
J
H
I
A
B
C
D
E
F
G
mantel
mantel
36 (914)
14 (356)*
53 (1346)
N/A
N/A
N/A
33 (838)
N/A
22 (558)
14 (356) 9** (229)
0 (00) In Masonry Wall
(N/A)
* (J mantel) with shield spaced 1 inch (25mm) away from bottom mantel surface.
** (I) With 52 inch (1321mm) high and 42 inch (1067mm) wide wall protection spaced 1 inch (25mm) from combustible surface.
NOTE: Wall protector must be a minimum of 24 gauge sheet metal with a 1 inch (25mm) air space between sheet metal and
combustible wall. Sheet metal may then be covered with brick or tile.
Page 10
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
Installation Considerations
4
In Canada, similar floor protection must be provided 18
inches (457mm) in front and 8 inches (203mm) from the
sides and rear of the stove. *See exception.
A. Hearth Protection Requirements
FLOOR PROTECTION: Floor protector must be non-
combustible material, extending beneath heater and to the
front, sides and rear as indicated. The floor must be non-
combustible or otherwise adequately protected from radiant
heat given off by the unit and from sparks and falling embers.
A layer of thin brick or ceramic tile over a combustible floor
is not sufficient.
*EXCEPTION: Non-combustible floor protections must
extend beneath the flue pipe when installed with horizontal
venting and extend 2 inches (51mm) beyond each side.
See Figure 11.4.
WARNING
In US installations, it is necessary to install a floor protec-
tor a minimum of 16 inches (406mm) in front of glass and 8
inches (203mm) to both sides of the fuel loading door. Open
the door and measure 8 inches (203mm) from the side edge
of the opening in the face of the appliance. *See exception.
Fire Risk.
• Hearth pads must be installed exactly as
specified.
High temperatures or hot embers may ignite
concealed combustibles.
203mm (8")
203mm
(8")
203mm
(8")
Fuel loading door
39-1/4"
Minimum
1219mm
(48")
Minimum
16" from glass - std legs
8"
457mm (18")
CANADA
USA
1137mm (44-3/4")
Minimum
36-3/4"
Minimum
Figure 11.1
Figure 11.2
51"
51"
must extend
length of flue and
2" (51mm)
beyond each
side of pipe
USA - Required
CANADA - Recommended
USA Installations
Figure 11.4
Figure 11.3
Page 11
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
B. Reversible Flue Collar
The flue collar is reversible for either a top or rear venting
installation. The unit is shipped with the flue collar in the top
vent position.
Converting Collar For Rear Vent Installation
1. Remove 5 Phillips head screws from the rear shield, lift
shield up and set aside.
2. Remove bolts from each side of the flue transition (2
total). (Place your free hand in flue opening to locate
and retrieve nuts attached to bolts.)
Mounting Screws
3. Turn vent to horizontal position. Inspect sealant to ensure
a leak free application.
Figure 12.2
4. Re-assemble in reverse order.
Rear Flue Deflector Cover Plate
Bend Flange Down
This cover plate is used when the flue collar is turned for a
rear vent application.
Please note this cover plate will not
work with the Low-Profile Kit
Figure 12.3
Figure 12.1
1. After the flue collar has been reversed for a rear vent
installation, install the cover plate on the stove with
the two screws provided. Figure 12.2.
2. Bend the cover plate flange down. Figure 12.3.
3. Secure the cover plate with the remaining two screws.
Page 12
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
C. Outside Air Kit Installation
D. Installation Of Optional Blower
The blower is shipped fully assembled and ready
for installation.
Included in Kit: 1 flex flange; 2 cable ties; oustide air termi-
nation cap; mounting screws (Discard the remaining parts).
1. Remove 3 Phillips head screws from rear of unit.
Items Needed for Installation: 4 inch (102mm) diameter
flex pipe in the length as required for your installation; Phil-
lips screwdriver; Silicone sealant; Drills and saws necessary
for cutting holes through the wall or flooring in your home.
2. Using the Phillips head screws, attach blower to lower
rear of stove, as shown.
3. Plug blower cord into a grounded outlet. Do not remove
ground prong from plug. Route power cord to avoid
heat from the stove, or other damage. Do not route
cord under or in front of appliance.
1. Remove all materials from packing box.
2. Mount the flex flange (with pipe fitting extending out),
over the intake air opening at the rear of stove using the
four mounting screws supplied with kit.
4. Adjust the blower speed control to the desired speed.
3. Cut a 4 inch (102mm) minimum hole in the floor or wall
to accommodate outside air piping. Use 4 inch (102mm)
metal flex or rigid piping to directly connect outside air to
the unit or into vented crawl space. (Do not put flex into
a non-vented crawl space).
*The blower speed control for this unit is adjusted at the factory,
and normally does not require further adjustment.
4. If using flex tubing attach cable ties to secure tubing at
both ends. Use the supplied termination cap with a rodent
screen. Seal between the floor or wall and the pipe with
silicone to prevent moisture penetration.
Rear Shield
Blower Mounting
Flange
Blower Speed Control
Blower
Mounting
Flange
OUTSIDE AIR
TERMINATION CAP
(contains rodent screen)
Rear
Shield
FLEX FLANGE
Figure 13.1
NOTE: If you plan to install the optional blower and the
outside air kit, complete installation of the outside
air kit first.
Figure 13.2
Page 13
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
Chimney Requirements
5
A. Venting Components
Chimney Connector:
B. Chimney Systems
Prefabricated Metal Chimney
It is also known as flue pipe or stove pipe. The chimney
connector joins the stove to the chimney. It must be a 6 inch
(152mm) minimum diameter 24 gauge mild steel black or
26 gauge blued steel, or an approved air-insulated double
wall venting pipe.
•
Must be minimum 6 inch (152mm) diameter (ID) high
temperature chimney listed to UL 103 HT (2100 F) or
o
ULC S629M.
•
•
•
Must use components required by the manufacturer for
installation.
Thimble:
Must maintain clearances required by the manufacturer
for installation.
A manufactured or site-constructed device installed in
combustible walls through which the chimney connector
passes to the chimney. It is intended to keep the walls
from igniting. Site constructed thimbles must meet
NFPA 211 Standards. Prefabricated must be suitable
for use with selected chimney and meet UL103 Type
HT Standards. Follow instructions provided by the
manufacturer for manufactured thimbles for masonry
chimney and prefabricated chimneys.
Refer to manufacturers instructions for installation.
NOTE: In Canada when using a factory-built chimney it must
be safety listed, Type UL103 HT (2100oF) CLASS “A” or
conforming to CAN/ULC-S629M, STANDARD FOR 650oC
FACTORY-BUILT CHIMNEYS.
Chimney:
Listed Termination Cap
Storm Collar
The chimney can be new or existing, masonry or
prefabricated and must meet the following minimum
requirements specified in Section 5B.
Flashing
Listed Termination Cap
Roof Brace (if required)
Listed Chimney
Storm Collar
Flashing
Ceiling Support
Chimney
Connector
Trim Collar on
Listed Chimney
Inside Wall
Insulated " T "
Chimney
Connector
Wall Support
Thimble
Floor
Protector
Floor
Protector
Figure 14.1 Prefabricated Exterior Chimney
Figure 14.2 - Prefabricated Interior Chimney
Page 14
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
Thimble
C
L
Site constructed for masonry chimney installation:
ceiling
Components
13.5” below ceiling to top
of opening
• A minimum length of 12 inches [305mm] (longer for
thicker walls) of solid insulated factory-built chimney
length constructed to UL 103 Type HT 6 inch (152mm)
inside diameter. Chimney needs to extend a minimum
of 2 inches (51mm) from the interior wall and a mini-
mum of 1 inch (25mm) from the exterior wall.
Wall
or top of opening is a min.of
4.5” below min.clearance
specified by connector mfg.
Minimum18.0”
NFPA 211
1.5 2x2 framing stud
2.0 min air clearance
1.0 min air clearance
4.5
1.5”
2.0”
1.0”
• Wall spacer, trim collar and wall band to fit solid pack
chimney selected.
17.0” OD
14.0” ID
8.0”
C
L
1.0”
2.0”
• Minimum 8 inch (203mm) diameter clay liner section (if
not already present in chimney) and refractory mortar.
1.5”
Center of Hole
Thimble
Air Clearances
• Masonry chimney clearance must meet NFPA 211 mini-
mum requirement of 2 inches (51mm) to sheet metal
supports and combustibles.
Include depth
of hearth pad
• Minimum of 1 inch (25mm) clearance around the chim-
ney connector.
• Top of wall opening is a minimum of 13-1/2 inches
(343mm) from ceiling or 4-1/2 inches (114mm) below
minimum clearance specified by chimney connector
manufacturer. NFPA 211 minimum vertical clearance of
18 inches (457mm) from chimney connector and ceil-
ing or minimum recommended by chimney connector
manufacturer. Figure 15.1.
Figure 15.1
Fire Clay Flue
Liner
with Airspace
Instructions:
1. Open inside wall at proper height for the chimney con-
Masonry
Chimney
nector to entry the masonry chimney. Figure 15.1
Trim Collar
2. Entry hole to masonry chimney must be lined with an 8
inch (203mm) minimum diameter clay liner, or equiva-
lent, secured with refractory mortar.
Wall Spacer
Chimney Section
with 2 inch
(51mm)
Clearance to
Combustibles
Wall Band to
Secure Chimney
Section
3. Construct a 17 inch x 17 inch (432mm x 432mm) out-
side dimension frame from 2 x 2 framing lumber to
fit into wall opening. Inside opening of frame should
be no less than 14 inch x 14 inch (356mm x 356mm).
Figure 15.1.
Chimney
Connector
Wood Studs Used
for Framing - Spaced
2 inch (51mm)
clearance from
Masonry Chimney
4. Attach the wall spacer to the chimney side of the frame.
Figure 15.2 - Solid Pack Chimney with Metal Supports
as a Thimble
5. Nail the frame into the wall opening. The spacer should
be on the chimney side.
6. Insert the section of the solid insulated chimney into
the outer wall of the masonry chimney.
WARNING
7. Tightly secure the length of the solid insulated chimney
with the wall band to the masonry chimney.
Fire Risk.
Do NOT pack insulation or other combustibles between
spacers.
8. Insert a section of chimney connector into the chimney.
Make sure it does not protrude past the edge of the
clay chimney liner inside the chimney.
•
ALWAYS maintain specified clearances around
venting and spacers.
Install spacers as specified.
•
9. Seal the end of the chimney connector to the clay liner
with refractory mortar.
Failure to keep insulation or other material away from
vent pipe may cause fire.
10. Install trim collar around the sold pack chimney section
.
Page 15
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
Masonry Chimney Liner
Min. Chimney Clearance to
Wall Spacer and
Combustibles - 2 inch (51mm)
Min. Clearance
2 inch (51mm)
For optimal performance, masonry chimneys used to vent
this appliance should be:
1 inch (25mm) Air
Space to Chimney
Section
1. Lined with a 6 inch (152mm) stainless steel liner.
Chimney Flue
Liner
• Installations into a clay flue without a stainless steel
liner may reduce draw which affects performance,
cause the glass to darken and produce excessive
creosote.
Fireclay
Liner or
Equivalent
Chimney
Connector
Chimney Section
Trim Collar
Wall Band
Wall Spacer
2. It is recommended that a chimney with a larger diameter
than 6 inches (152mm) be relined.
Masonry Chimney
Constructed to NFPA 211
• The oversized flue can cause poor performance and
contribute to the accumulation of creosote.
3. Have the chimney cleaned before the stove is installed
and operated.
Figure 16.1 - Solid Pack Chimney with Metal Supports
as a Thimble (Cont’d)
The following bullets list the more critical requirements for a
properly constructed chimney:
Chimney Height / Rise and Run
This product was designed for and tested on a 6 inch
(152mm) chimney, 12 to 14 feet (420-480cm) high, (includes
stove height) measured from the base of the appliance to
the the top of the chimney (not including chimney cap).
The further your stack height or diameter varies from this
configuration, the possibility of performance problems exists.
•
The masonry wall of the chimney, if brick or modular
block, must be a minimum of 4 inches (102mm) nominal
thickness.
•
•
A chimney of rubble stone must be at least 12 inches
(305mm) thick.
The chimney must have a fire clay flue liner (or equivalent)
with a minimum thickness of 5/8 inch (16mm) and must
be installed with refractory mortar.
Chimney height may need to be increased by 2 - 3% per
each 1000 feet above sea level. It is not recommended to
use offsets or elbows at altitudes above 4000 feet above sea
level or when there are other factors that affect flue draft.
•
An equivalent liner must be a listed chimney liner system
or other approved material.
•
•
Since an oversized flue contributes to the accumulation
of creosote, the size of the flue should be checked to
determine that it is not too large for the insert.
WARNING
Fire Risk.
The chimney should also be checked to ensure it meets
the minimum standard of the National Fire Protection
Association (NFPA) Standard 211.
Inspection of Chimney:
•
•
•
Chimney must be in good condition.
Meets minimum standard of NFPA 211
•
•
A chimney support package must be used when a
connection is made through the ceiling to a factory built
chimney.
Factory-built chimney must be 6 inch
(152mm) UL103 HT.
An approved thimble and chimney support package
are absolutely necessary to provide safe clearances to
combustible wall and ceiling material.
WARNING
Asphyxiation Risk.
NOTICE: In Canada, the installation shall conform to
CAN/CSA-B365.
• DO NOT CONNECT THIS UNIT TO A CHIM-
NEY FLUE SERVICING ANOTHER APPLI-
ANCE.
•
DO NOT CONNECT TO ANY AIR DISTRIBU-
TION DUCT OR SYSTEM.
NOTICE: Check with your local building authorities
and/or consult the National Fire Protection Association
(NFPA 211).
May allow flue gases to enter the house.
Page 16
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
Masonry Chimney Liner (Cont'd)
C. Installing Chimney Components
Chimney Connector
Wood Stud 2 in.
(51mm)
Single wall connector or stove pipe.
This must be at least 24 gauge mild steel or 26 gauge blue
steel. The sections must be attached to the appliance and
to each other with the crimped (male) end pointing toward
the stove. All joints, including the connection at the flue
collar, should be secured with 3 sheet metal screws. Make
sure to follow the minimum clearances to combustibles.
Where passage through the wall, or partition of combustible
construction is desired in Canada, the installation shall
conform to CAN/CSA-B365.
Clearance from
chimney wall
Fireclay liner 5/8 in.
(16mm) Minimum
or Equivalent.
Header
Factory-built listed chimney connector (vented).
A listed connector (vented) must be used when installing
this unit in a mobile home. The listed connectors must
conform to each other to ensure a proper fit and seal.
Fireclay liner 5/8 in.
(16mm) Minimum
or Equivalent.
Sill support
Crimped
Flue Gas
End
Direction
Toward
Stove
Thimble Assembly:
12 in. (305mm) of
brick separation
between clay liner
and combustibles.
Secure pipe sections with a
minimum of 3 screws
Figure 17.2 Chimney Connector (Stove Pipe)
Figure 17.1
WARNING
Fire Risk.
WARNING
Follow Chimney Connector Manufacturer’s
Instructions for Proper Installation.
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. Refer
to the owner’s information manual provided with this appli-
ance. For assistance or additional information consult a
qualified installer, service agency or your dealer.
ONLY use connector:
Within the room, between appliance and ceiling or wall.
Connector shall NOT pass through:
•
•
•
•
Attic or roof space
Closet or similar concealed space
Floor or ceiling
Maintain minimum clearances to combustibles
Page 17
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
D. Chimney Termination Requirements
NOTE:
Follow manufacturer’s instructions for clearance, securing
flashing and terminating the chimney.
•
•
Chimney performance may vary.
Trees, buildings, roof lines and wind conditions affect
performance.
•
•
Must have an approved and listed cap
•
Chimney height may need adjustment if smoking or
overdraft occurs.
Must not be located where it will become plugged by
snow or other material
•
Must terminate at least 3 feet (91cm) above the roof
and at least 2 feet (61cm) above any portion of the
roof within 10 feet (305cm).
•
Must be located away from trees or other structures
E. 2-10-3 Rule
These are safety requirements and are not meant to assure proper flue draft.
Less than 10 ft. (305cm)
2 ft. (61cm)
3 ft. (91cm)
Minimum
2 ft. (61cm)
10 ft. (305cm) To Nearest Roofline
3 ft. (91cm)
Minimum
Pitched Roof
Figure 18.1
10 ft. (305cm) or more
Less than 10 ft. (305cm)
Wall or Parapet
2 ft. (61cm)Minimum
3 ft. (91cm) Minimum
3 ft. (91cm) Minimum
Figure 18.2
250-5763E
Page 18
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
Mobile Home Installation
6
You must use a Quadra-Fire Outside Air Kit Part
831-1780 for installation in a mobile home.
1. An outside air inlet must be provided for combustion See
page 13 for installation information.
2. Appliance must be secured to the mobile home structure
by bolting the pedestal through hearth pad and into floor.
3. Appliance must be grounded with #8 solid copper
grounding wire or equivalent and terminated at each end
with N.E.C. approved grounding device.
4. Appliance must be installed with an approved UL103 HT
ventilated chimney connector, UL103 HT chimney, and
terminal cap with spark arrestor. Never use a single wall
connector (stove pipe) in a mobile home installation. Use
only double-wall connector pipe, Dura-Vent DVL, Selkirk
metalbestos DS or Security DL double-wall connector or
any listed double-wall connector pipe.
OUTSIDE AIR
TERMINATION CAP
(contains rodent screen)
5. In Canada, this appliance must be connected to a 6 inch
(152mm) factory-built chimney conforming to CAN/ULC-
629M, STANDARD FOR FACTORY BUILT CHIMNEYS.
FLEX FLANGE
Figure 19.1
6. Followthechimneyandchimneyconnectormanufacturer’s
instructions when installing the flue system for use in a
mobile home.
7. Maintain clearance to combustibles.
CAUTION
8. Floor protection requirements must be followed precisely.
THE STRUCTURAL INTEGRITY OF THE MOBILE HOME
FLOOR, WALL AND CEILING/ROOF MUST BE MAIN-
TAINED
9. Use silicone to create an effective vapor barrier at
the location where the chimney or other component
penetrates to the exterior of the structure.
Do NOT cut through:
•
•
Floor joist, wall, studs or ceiling trusses.
Any supporting material that would affect the structural
integrity.
NOTE: Offsets from the vertical, not exceeding 45°, are
allowed per Section 905(a) of the Uniform Mechanical Code
(UMC). Offsets greater than 45° are considered horizontal
and are also allowed, providing the horizontal run does not
exceed 75% of the vertical height of the vent. Construction,
clearance and termination must be in compliance with the
UMC Table 9C. This installation must also comply with NFPA
211.
WARNING
NOTE: Top sections of chimney must be removable to allow
maximum clearance of 13.5 feet (411cm) from ground level
for transportation purposes.
Asphyxiation Risk.
NEVER INSTALL IN A SLEEPING ROOM.
Consumes oxygen in the room.
10. Burn wood only. Other types of fuels may generate
poisonous gases (e.g., carbon monoxide).
11. If unit burns poorly while an exhaust blower is on in
home, (i.e., range hood), increase combustion air.
12. Installation shall be in accordance with the Manufacturers
Home & Safety Standard (HUD) CFR 3280, Part 24.
Page 19
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
Appliance Set-Up
7
B. Adjusting The Blower Speed Control
A. Door Handle Assembly
If Necessary
Included in Kit: 1 locknut, 1 porcelain handle, 1 screw
adapter, 1 gold or nickle handle, 1 square key, 4 spacing
washers, 1 cam latch
NOTE: When the speed control is turned clockwise, it will
click on to high speed. Turn the speed control
clockwise to decrease the speed. At full
clockwise, the blower should blow gently, but
should not stop.
Tools Needed: 9/16 box end wrench, flat head screwdriver.
1. With the stove plugged in, turn the speed control knob
to slow (full clockwise).
Latch Cam
Door Cross Section
Locknut
Handle
2. With a small screwdriver, adjust the blower speed by
turning the adjustment mechanism through the hole on
the side of the speed control.
3. Adjust the speed so the blower runs slowly, but does
not stop. Turn clockwise to slow the blower and
counterclockwise to increase the speed.
Teflon Washer
Spacing Washers
DO NOT
REMOVE
Square Key
Figure 20.1
Thread
End
Porcelain
Handle
Figure 20.2
1. Install teflon washer on door handle shaft.
2. Slide door handle through door.
3. Install spacing washers(s) as showin in Figure 20.1.
4. Install key in groove.
5. Align groove in latch cam with key; slide latch cam over
shaft.
6. Install locknut but do not overtighten, the handle needs
to move smoothly.
INSTALL PORCELAIN HANDLE:
1. Insert handle adapter with threads going into the porce-
lain handle. Figure 20.2.
2. Thread in completely, using a flat head screwdriver.
Page 20
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
Operating Instructions
8
B. Wood Selection and Storage
A. Over-Firing Your Appliance
WARNING
Fire Risk
Do not over-fire.
WARNING
FIRE RISK.
• DO NOT BURN GARBAGE OR FLAMMABLE
FLUIDS SUCH AS GASOLINE, NAPTHA OR
ENGINE OIL.
Over-firing may ignite creosote or will damage
the stove and chimney.
• DO NOT USE CHEMICALS OR FLUIDS TO START A
FIRE.
To prevent over-firing your stove, DO NOT:
•
•
•
•
Use flammable liquids
Overload with wood
Burn trash or large amounts of scrap lumber
Permit too much air to the fire
• Do NOT burn treated wood or wood with salt (driftwood).
• May generate carbon monooxide if burn material other
than wood.
May result in illness or possible death.
1. Symptoms of Over-Firing
Symptoms of over-firing may include one or more of the
following:
Hardwood vs Softwood
Your appliance performance depends on the quality of the
firewood you use.
• Chimney connector or appliance glowing
• Roaring, rumbling noises
• Loud cracking or banging sounds
• Metal warping
•
•
•
•
Seasoned wood contains about 8,000 BTUs per pound .
Hard woods are more dense than soft woods.
Hard woods contain 60% more BTUs than soft woods.
• Chimney fire
Hard woods require more time to season, burn slower and
are harder to ignite.
2. What To Do if Your Stove is Over-Firing
•
•
•
Soft woods require less time to dry, burn faster and are
easier to ignite.
• Immediately close the door and air controls to reduce
air supply to the fire.
Start the fire with softwood to bring the appliance up to
operating temperature and to establish draft.
• If you suspect a chimney fire, call the fire department
and evacuate your house.
Add hardwood for slow, even heat and longer burn time.
• Contact your local chimney professional and have
your stove and stove pipe inspected for any damage.
• Do not use your stove until the chimney professional
informs you it is safe to do so.
Soft woods
Hard woods
•
•
•
•
Douglas Fir
Pine
Spruce
Cedar
• Oak
• Maple
• Apple
• Birch
• Poplar
• Aspen
• Alder
Hearth & Home Technologies WILL NOT warranty stoves
that exhibit evidence of over-firing. Evidence of over-firing
includes, but is not limited to:
• Warped air tube
• Deteriorated refractory brick retainers
• Deteriorated baffle and other interior components
Processed Solid Fuel Fire Logs
NOT permitted for use in this appliance
•
Page 21
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
Moisture
C. Burning Process
The majority of the problems appliance owners experience
are caused by trying to burn wet, unseasoned wood.
In recent years there has been an increasing concern about
air quality. Much of the blame for poor air quality has been
placed on the burning of wood for home heating.
•
Wet, unseasoned wood requires energy to evaporate the
water instead of heating your home, and
In order to improve the situation, we at Quadra-Fire have
developed cleaner-burning wood appliances that surpass
the requirements for emissions established by our governing
agencies.
•
Causes evaporating moisture which cools your chimney,
accelerating formation of creosote.
WARNING
These wood appliances must be properly operated in order
to ensure that they perform the way they are designed to
perform.
Fire Risk.
•
•
•
Do NOT burn wet or green wood.
Store wood in dry location.
Stack wood so both ends are exposed to air.
NOTICE: Improper operation can turn any wood appli-
Wet, unseasoned wood can cause accumulation of
creosote.
ance into a smoldering environmental hazard.
1. Kindling or First Stage
Seasoned Wood
It helps to know a little about the actual process of burning in
order to understand what goes on inside the appliance. The
first stage of burning is called the kindling stage.
•
•
•
Cut logs to size
Split to 6 inches (152 mm) or less in diameter
Air dry to a moisture content of not more than 20%
In this stage:
• Wood is heated to a temperature high enough to evapo-
rate the moisture present in all wood.
-
-
Soft wood - about nine months to dry
Hard wood - about eighteen months to dry
• Wood will reach the boiling point of water (212°F) and will
not get any hotter until the water is evaporated.
NOTICE: Seasoning time may vary depending on drying
conditions.
This process takes heat from the coals and tends to cool the
appliance.
Fire requires three things to burn:
Storing Wood
• Fuel
• Air
Steps to ensure properly seasoned wood:
•
•
•
•
Stack wood to allow air to circulate freely around and
through woodpile.
• Heat
If heat is robbed from the appliance during the drying stage,
the new load of wood has reduced the chances for a good
clean burn.
Elevate wood pile off ground to allow air circulation
underneath.
Smaller pieces of wood dry faster. Any piece over 6 in.
(152 mm) in diameter should be split.
It is always best to burn dry, seasoned firewood. When the
wood isn’t dry, you must open the air controls and burn at a
high burn setting for a longer time to start it burning.
Wood (whole or split) should be stacked so both ends of
each piece are exposed to air. More drying occurs through
the cut ends than the sides.
The heat generated from the fire should be warming your
home and establishing the flue draft, not evaporating the mois-
ture out of wet, unseasoned wood, resulting in wasted heat.
•
Store wood under cover to prevent water absorption
from rain or snow. Avoid covering the sides and ends
completely.
2. Second Stage
In the secondary stage wood gives off flammable gases which
burn above the fuel with bright flames.
WARNING
Fire Risk
During this stage of burning:
• The flames must be maintained and not allowed to go out
to ensure the cleanest possible fire.
• If the flames tend to go out, it is set too low for your burn-
ing conditions.
Do NOT store wood:
•
•
In front of the appliance.
In space required for loading or ash
removal.
Page 22
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
E. Air Controls
The Primary Air Slide Control located under the ashlip ad-
justs the burn rates. Figure 23.1.
Start-Up Air System
The combustion air enters at the rear of the firebox through
the rear air tubes. This air supply is controlled by the Start-
up Air Control. For more air push control in, for less air pull
control out.
3. Final Stage
The final stage of burning is the charcoal stage. This occurs
when the flammable gases have been mostly burned and
only charcoal remains. This is a naturally clean portion of
the burn. The coals burn with hot blue flames.
Primary Air System
The primary air enters below the ash catcher and is directed
to the upper front of the firebox, near the top of the glass
door and to the lower front of firebox. This preheated air sup-
plies the necessary fresh oxygen to mix with the unburned
gases, helping to create secondary, tertiary and quaternary
combustions. This air is regulated by the Primary Air Slide
Control. For more primary air slide control left, for less air,
slide control to the right.
• It is very important to reload your appliance while enough
lively hot coals remain in order to provide the amount of
heat needed to dry and rekindle the next load of wood.
•
It is best to open the Primary Air Slide Control and the
Start-Up Air Controls before reloading. This livens up
the coalbed and reduces excessive emissions (opacity/
smoke).
• Open door slowly so that ash or smoke does not exit ap-
pliance through opening.
• Break up any large chunks and distribute the coals so
that the new wood is laid on hot coals.
Air quality is important to all of us, and if we choose to use
wood to heat our homes we should do so responsibly.
We need to learn to burn in the cleanest way possible al-
lowing us to continue using our wood appliances for many
years to come.
Primary Air
Start-Up Air
Slide Control
Control
Start-Up Control
OPEN - PUSH IN
Primary Slide Control
OPEN - SLIDE LEFT
CLOSE - SLIDE RIGHT
D. Combustible/Non-Combustible Materials
•
Combustible Material
CLOSED - PULL OUT
Material made of or surfaced with wood, compressed
paper, plant fibers, plastics, or any material capable
of igniting and burning, whether flame-proofed or not,
plastered or unplastered.
Figure 23.1
•
Non-Combustible Material
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, slate,
glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
o
Vertical Tube Furnance at 750 C and UL763 shall be
considered non-combustible materials.
•
Non-Combustible Sealant Material
Sealants which will not ignite and burn: Rutland, Inc.
Fireplace Mortar #63, Rutland 76R, Nuflex 304, GE
RTV106 or GE RTB116 (or equivalent).
Page 23
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
G. Heat Output Settings
F. Operating The Top Loading Option
For maximum operating efficiency with the lowest
emissions, follow these operating procedures:
NOTICE: SHIPPING BOLTS MUST BE REMOVED
PRIOR TO REMOVING GRIDDLE.
1. Regardless of desired heat output, when loading stove,
burn it with both air controls wide open for 5 to 15 min-
utes.
NOTE: There are 3 fiber door handles for this appliance.
They are for the door, baffle by-pass handle and
the top-loading griddle slot.
2. Regulate burn rate (heat output) by using the PrimaryAir
Slide Control (center under ashcatcher). The Start-Up
Air Control (on the right) is used for initial start-up and
reloading.
1. Using a 7/16 wrench, remove the 2 shipping bolts under-
neath the griddle before lifting the griddle off of stove.
3. Heat output settings are listed below, following 5 to 15
minutes of burning with controls wide open (see #1
above):
2. Open by-pass door by moving the side handle towards
rear of stove.
4. Burn dry, well-seasoned wood.
3. Wait 15 seconds to allow smoke to clear out of firebox.
4. Slowly open top loading door and load unit with fuel.
5. Close the top door.
H. Burn Rates
6. Close the by-pass door (move side handle towards front
of stove.)
1. High Burn Rate - Maximum Heat* - 40,000+ BTU/hr
•
Close Start-Up Air Control after 5 to 15 minutes, fully open
(all the way to the left) the Primary Air Slide Control.
2. Medium-High Burn Rate*
-
15,000 to 40,000 BTU/hr
WARNING
•
Close Start-Up Air Control after 5 to 15 minutes, open the
Injury Risk.
Primary Air Slide Contro 1-1/2 inch to 1-1/8 inch.
emove the door handle during operation to
prevent:
3
.
Medium-Low Burn Rate* - 10,000 to 15,000 BTU/hr
• Handle may overheat and may cause burns to
your hands.
Wear protective gloves when operating the draft
control knobs as they become hot during operation
•
Close Start-Up Air Control after 5 to 15 minutes, open the
Primary Air Slide Contro 1-1/8 inch to 1/2 inch.
4. Low Burn Rate* - Below 10,000 BTU/hr
•
Close Start-Up Air Control after 5 to 15 minutes, slide the
Primary Air Slide Control all the way to the right.
WARNING
Fire Risk.
*NOTE: These are approximate settings, and will vary with
type of wood or chimney draft. Due to altitude and other
environmental circumstances, this operational information is
a guideline only.
•
ALWAYS OPERATE THIS APPLIANCE WITH
THE DOOR CLOSED AND LATCHED EXCEPT
DURING START-UP AND RE-FUELING OR
WHEN USING THE FIRESCREEN.
•
OPERATING WITH THE DOOR PARTLY OPEN
CAN CAUSE:
WARNING
Risk of extreme temperatures!
•
HOT EMBERS OR SPARKS TO FALL OUT
• FLAMES AND SMOKE MAY BE DRAWN OUT
FROM FIREBOX OPENING
• Do not operate with Start-Up Air Control in the open position
in excess of 15 minutes!
• Prolonged operation with the Start-Up Air Control in the open
position may cause the combustible materials around the
stove to exceed safe temperature limits.
Page 24
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
I. Building A Fire
WARNING
Before lighting your first fire make certain that the
baffle is correctly positioned. It should be resting
against the rear support.
Fire Risk.
• DO NOT BURN GARBAGE OR FLAMMABLE
FLUIDS SUCH AS GASOLINE, NAPTHA OR
ENGINE OIl.
There are many ways to build a fire. The basic principle
is to light easily-ignitable tinder or paper, which ignites the
fast burning kindling, which in turn ignites the slow-burning
firewood. Here is one method that works well:
• Do NOT burn treated wood or wood with salt (driftwood).
• May generate carbon monoxide if burn material other
than wood.
May result in illness or possible death.
1. Place several wads of crushed paper on the firebox floor.
Heating the flue with slightly crumpled newspaper
before adding kindling keeps smoke to a minimum.
WARNING
2. Lay small dry sticks of kindling on top of the paper.
Fire Risk.
3. Open Start-Up Air Control and Primary Air Slide Control
fully. After 5 to 15 minutes, when the fire is well established,
gently pull Start-Up Air Control forward until resistance is
felt. Do not allow control to "spring back" into the open
position.
Keep combustible materials, gasoline
and other flammable vapors and liquids
clear of appliance.
•
•
Do NOT store flammable materials in the appliance’s
vicinity.
4. Make sure that no matches or other combustibles are
in the immediate area of the stove. Be sure the room is
adequately ventilated and the flue unobstructed.
DO NOT USE GASOLINE, LANTERN FUEL,
KEROSENE, CHARCOAL LIGHTER FLUID OR
SIMILAR LIQUIDS TO START OR “FRESHEN UP” A
FIRE IN THIS HEATER.
5. Light the paper in the stove. NEVER light or rekindle stove
with kerosene, gasoline, or charcoal lighter fluid;the results
can be fatal.
•
•
Keep all such liquids well away from the heater while it
is in use.
6. Once the kindling is burning quickly, add several full-length
logs 3 inches (76mm) or 4 inches (102mm) in diameter.
Be careful not to smother the fire. Stack the pieces of
wood carefully: near enough to keep each other hot, but
far enough away from each other to allow adequate air
flow between them.
Combustible materials may ignite.
WARNING
Fire Risk.
7. When ready to reload the stove, add more logs. Large
logs burn slowly, holding a fire longer. Small logs burn fast
and hot, giving quick heat.
•
•
Do not leave the fire unattended when the door
is unlatched or when using the firescreen.
8. Adjust the Start-Up Air Control and Primary Air Slide Con-
trol; the more you close down (slide right) the Primary Air
Slide Control, the lower and slower the fire will burn. The
more you open (slide left) the Primary Air Slide Control,
the more heat will be produced. The Start-Up Air Control
is only used for the first 5 to 15 minutes.
Unstable firewood could fall out of the firebox
creating a fire hazard to your home.
CAUTION
9. As long as there are hot coals, repeating steps 7 and 8 will
maintain a continuous fire throughout the season.
Odors and vapors released during initial operation.
•
•
Curing of high temperature paint.
Open windows for air circulation.
NOTE: The special high temperature paint that your stove is
finished with will cure as your stove heats. You will
notice an odor and perhaps see some vapor rise from
the stove surface; this is normal. We recommend that
you open a window until the odor dissipates and paint
is cured.
Odors may be irritating to sensitive individuals.
NOTE:
NOTE: Stove should be run full open for 15 minutes a day to
• Build fire on brick firebox floor.
• Do NOT use grates, andirons or other methods to support
fuel.
keep air passages clean.
It will averserly affect emissions.
Page 25
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
M. Clear Space
J. Optional Blower Operating Instructions
•
Do NOT place combustible objects within 4 ft (1.2 m) of
the front of fireplace. Figure 26.1.
1. Initial (cold) start-up: Leave blower off until your stove
is hot and a good coalbed is established. The blower
may be turned on approximately 30 minutes after a good
coalbed is established.
WARNING
2. High burn setting: The blower may be left on through-
Fire Risk.
out the burn at your desired setting.
•
Do not place combustible objects within 48 inches
in front of the appliance.
3. Medium burn settings: The blower should be left off
until a good burn is established, then turned on at your
desired setting.
•
High temperatures may ignite clothing, furniture or
draperies.
4. Low burn setting: The blower tends to cool off the
stove. Leave blower off until burn is well established.
Then turn on at your desired rate.
5. The highest blower speed is obtained by turning the
speed control on and then adjusting counterclockwise
towards "OFF" as far as possible without turning the
blower off. For a low blower speed, turn the control knob
clockwise as far as possible.
K. Opacity (Smoke)
Opacity is the measure of how cleanly your appliance is
burning.
Maintain 4 ft (1.22m) clearance to
combustible in front of appliance
Opacity is measured in percent:
• 100% opacity is when an object is totally obscured by
the smoke column from a chimney, and
• 0% opacity means that no smoke column can be seen.
As you become familiar with your appliance, you should peri-
odically check the opacity. This will allow you toknow how to
burn as nearly smoke-free as possible (goal of 0% opacity).
Figure 26.1 - Clear Space
WARNING ! THE OUTSIDE SURFACES OF THIS UNIT WILLBECOME
EXTREMELY HOT DURING USE. IF THIS APPLIANCE IS IN A HIGH
TRAFFICAREAOR CHILDREN MAY BE NEAR IT IS RECOMMENDED
THAT YOU PURCHASE A DECORATIVE BARRIOR TO GO IN FRONT
OF THE APPLIANCE. ALWAYS KEEP CHILDREN AWAY WHILE IT
IS OPERATING AND DO NOT LET ANYONE OPERATE THIS APPLI-
ANCE UNLESS THEY ARE FAMILIAR WITH THESE OPERATION
INSTRUCTIONS.
L. Frequently Asked Questions
ISSUES
SOLUTIONS
Odor from appliance
When first operated, this appliance may release an odor for the first several hours. This is
caused by the curing of the paint and the burning off of any oils remaining from manufacturing.
Metallic noise
Noise is caused by metal expanding and contracting as it heats up and cools down, similar to
the sound produced by a furnace or heating duct. This noise does not affect the operation or
longevity of the appliance.
Whirring sound
The blower may produce a whirring sound which increases in volume as the speed is
increased.
Page 26
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
Maintaining & Servicing Your Appliance
9
2. Ash Removal System (ARS) Operating and Cleaning
A. General Maintenance
•
•
Frequency: Weekly when in constant operation or as
needed.
By: Homeowner
1. Creosote (Chimney) Cleaning
•
Frequency: Every 2 months during heating season or as
recommended by a certified chimney sweep; more frequently
if chimney exceeds or is under 12-14 ft. (measured from base
of appliance)
CAUTION
Injury Risk.
•
By: Certified Chimney Sweep
•
•
Gloves recommended
1. Remove all ash from the firebox and extinguish all hot embers
before disposal. Allow the appliance to cool completely. It is
also recommended that before each heating season the entire
system be professionally inspected, cleaned and repaired if
necessary.
Ash coals can remain extremely hot for
several days.
1. The stove and ashes must be completely cooled down before
using the Ash Removal System.The hinged door will open
from the right hand side. Pull ash pan out carefully.
2. Close the door tightly and proceed with sweeping the chimney.
3. Sweep the collected ashes into the ash removal box, and empty.
Clean out the remaining ashes from firebox.
2. Clean ash down through the ash removal system grate into
the drawer below. If there are large pieces in the ashes, you
can remove the grate before brushing the ash into the drawer.
4. Open top-loading door and vacuum out.
3. Be sure to replace the grate before operating the stove.
Remember to leave 1/4 to 1/2 inch (6-13mm) of ash on the
firebox floor to act as a natural grate, allowing air to flow freely
underneath wood
Inspection: Inspect the system at the appliance connection and at
the chimney top. Cooler surfaces tend to build creosote deposits
quicker, so it is important to check the chimney from the top as well
as from the bottom.
4. Replace ash pan and close ash door handle. Dispose of the
Formation and Need For Removal: When wood is burned slowly, it
produces tar and other organic vapors which combine with expelled
moisture to form creosote.
ashes following the directions on page 23.
The creosote vapors condense in the relatively cool chimney flue
of a newly-started or a slow-burning fire. As a result, creosote
residue accumulates on the flue lining. When ignited, this creosote
creates an extremely hot fire which may damage the chimney or
even destroy the house.
The chimney connector and chimney should be inspected once
every 2 months during the heating season to determine if a creosote
or soot buildup has occurred. If creosote or soot has accumulated,
it should be removed to reduce the risk of a chimney fire.
Ash Door
Handle
Swings Open
WARNING
Figure 27.1
Fire Risk.
Prevent creosote buildup.
Inspect chimney connector and chimney once
every two months during heating season.
WARNING
Fire risk
Injury risk
• Remove creosote to reduce risk of chimney fire.
• Ignited creosote is extremely HOT.
Make sure ash removal system door
Air leakage may cause:
• Over-fire condition.
• Flame and/or smoke spillage.
• Wood to burn too fast.
WARNING
Fire Risk.
•
•
Do not operate with ash pan door open or
with ash pan removed.
•
Do not use chimney cleaners or flame
colorants in your appliance.
Will corrode pipe.
DO NOT allow ashes to build up.
Page 27
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
3. Disposal of Ashes
5. Glass Cleaning
•
•
Frequency: As desired
By: Homeowner
•
•
Frequency: When ash is within 1-3/4 in. (44mm) of firebox
lip
By: Homeowner
Clean glass with a non-abrasive glass cleaner. Abrasive
cleaners may scratch and cause glass to crack. If the
deposits on the glass are not very heavy, normal glass
cleaners work well. Heavier deposits may be removed
by using a damp cloth dipped in wood ashes or by using
a commercially available oven cleaner.
Ashes should be placed in a metal container with a
tight fitting lid. The closed container of ashes should
be placed on a non-combustible floor or on the ground,
well away from all combustible materials, pending final
disposal.
After using an oven cleaner, it is advisable to remove any
residue with a glass cleaner or soap and water. Oven
cleaner left on during the next firing can permanently
stain the glass and damage the finish on plated metal
surfaces.
If the ashes are disposed of by burial in soil or otherwise
locally dispersed, they should be retained in the closed
container until all cinders have thoroughly cooled.
Aportion of the combustion air entering the firebox is deflected
down over the inside of the door glass. This air flow “washes”
the glass, helping to keep smoke from adhering to its surface.
WARNING
Fire Risk.
Disposal of Ashes
When operated at a low burn rate, less air will be flowing over
the glass and the smokey, relatively cool condition of a low
fire will cause the glass to become coated.
•
Ashes should be placed in metal container with tight
fitting lid.
•
•
Do not place metal container on combustible surface.
Ashes should be retained in closed container until all
cinders have thoroughly cooled.
Operating the appliance with the Primary Air Control all
the way open for 15-20 minutes should remove the built up
coating.
4. Cleaning Plated Surfaces
CAUTION
•
•
Frequency: Prior to first burn and then as desired
By: Homeowner
Handle glass assembly with care.
Clean all the fingerprints and oils from plated surfaces
BEFORE firing the appliance for the first time. If not
cleaned properly before lighting your first fire, the oils
can cause permanent markings on the plating.
Glass
Assembly
When cleaning glass:
•
Avoid striking, scratching or
slamming glass.
•
Do NOT clean glass when hot.
After the plating is cured, the oils will not affect the
finish and little maintenance is required. Wipe clean
as needed.
•
•
•
•
Do NOT use abrasive cleaners.
Use a hard water deposit glass cleaner on white film.
Use commerical oven cleaner on heavier deposits.
Remove all residue of oven cleaner or will permanently
stain glass on next firing.
•
Refer to maintenance instructions.
CAUTION
•
Do not use polishes with abrasives.
It will scratch plated surfaces.
Page 28
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
D. Glass Replacement
B. Appliance Inspection - Routine
1. Ensure that the fire is out and the appliance is cool
to the touch.
2. Protect a table or counter top with padding or towels.
Protect your hands and wear gloves to prevent injury.
3. Remove the door with the broken glass by lifting the
door up and off of the hinges.
•
Frequency: Every 2 months at the same time the chim-
ney and chimney connector are inspected.
•
By: Homeowner
Check for:
• Cracks in glass
4. Lay door face down on a table or counter making sure
the handle and handle attachment knob hangs over
the edge so the door lays flat on a soft surface.
5. Remove the screws from each glass retainer and
remove the glass. (If screws are difficult to remove,
soak with penetrating oil first).
6. Center the glass with edges evenly overlapping the
opening in the door, (i.e. same space top and bottom,
left and right sides).
• Door handle - smooth cam operation
• Baffles are in correct placement
• Baffle for warpage
• Firebrick for cracks, broken or crumbly
• Door gasket. (Dollar bill test). Place a dollar bill between
the stove and the door and then shut the door. If you can
pull the dollar bill out, replace the door gasket.
7. Replace the glass retainers. Be careful not to cross
thread the screws.
• Glass frame for loose screws
8. Tighten each retainer just a few turns until each is
secured. Check again for centering of glass in door
frame. Continue to tighten each retainer alternately,
a few turns at a time, until the glass is snug. DO NOT
OVERTIGHTEN.
C. Inspect Firebrick & Replacement
Instructions
•
•
Frequency: After each ash removal
By: Homeowner
9. Replace the door on the appliance.
Replace the firebrick if they become crumbly and/or if there
is a 1/4 inch (6.35mm) gap between the bricks.
Quadra-Fire stoves are equipped with ceramic super
heat-resistant glass, which can only be broken by impact
or misuse.
The firebox is lined with firebrick, which has exceptional in-
sulating properties. Do not use a grate; simply build a fire on
the firebox floor. Do not operate appliance without firebrick.
Do not slam stove door or impact the glass. When closing
door, make sure that logs do not protrude against the
glass. Inspect glass regularly.
Ensure that the firebricks are correctly positioned and that
the firebox does not contain any broken brick prior to operat-
ing the unit.
If you find a crack or break, immediately put the fire out
and return the door to your dealer for replacement of glass
before further use.
1. After the coals have completely cooled, remove all old
brick and ash from unit and vacuum out firebox.
2. Remove new brick set from box and lay out to the
diagram shown in the instructions that come with the
replacement brick set
WARNING
Handle glass with care.
•
Inspect the gasket to ensure it is
undamaged.
3. Lay bottom bricks in unit.
Glass
Assembly
4. Install rear bricks on the top of the bottom bricks. Slide
top of bricks under clip on back of firebox wall and push
bottom of bricks back.
•
•
Do NOT strike, slam or scratch glass.
Do NOT operate appliance with glass
& door assembly removed.
•
Do NOT operate with glass cracked, broken or scratched.
5. Install side bricks. Slide top of brick under clips on side
of firebox and push the bottom of the brick until it is flush
with the side of the unit.
WARNING
Use Part #832-0550 when ordering individual
brick. Provide brick dimension or copy the page
in the Service Parts List showing the brick dia-
gram, mark the desired brick and take it to your
authorized dealer.
Fire Risk.
Injury Risk.
•
•
Use only glass specified in manual.
DO NOT REPLACE with any other material.
Glass breakage will occur.
Page 29
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
Start the first inspection after the first 2 months of use,
or if performance changes, and adjust your schedule
accordingly. Maintenance is required for safe operation
and must be performed to maintain your warranty.
E. Quick Reference Maintenance Guide
CAUTION! Allow the appliance to completely cool
down before performing any cleaning or maintenance.
Task
Frequency
Baffle
Baffle placement is critical to heat output, ef-
ficiency and overall life of the unit. Make sure
the baffle is pushed all of the way to the back
of the firebox. Inspect baffle for cracks.
MONTHLY
or
After Every
Cord of Wood
Baffle
Optional Blower
Vacuum the blower impellers.
YEARLY
or
After Every
4 Cords of
Wood
Chimney System
The chimney and chimney cap must be inspect-
ed for soot and creosote every two months
during the burn season or more frequency if
chimney exceeds or is under 14-16 ft. (4.3m-
4.8m) measured from bottom of appliance.
EVERY 2
MONTHS
or
After Every
4 Cords of
Wood
This will prevent pipe blockage, poor draft, and
chimney fires.
Always burn dry wood to help prevent cap
blockage and creosote build-up.
Firebrick & Ash Removal
Ashes must be cool before you can dispose of
the ashes in a non-combustible container.
WEEKLY
or
After Every
25 Loads of
Wood
Firebrick is designed to protect your firebox.
After ashes are removed, inspect the firebrick
and replace firebricks that are crumbling,
cracked or broken.
Keep door and glass gasket in good shape to
maintain good burn times on a low burn setting.
To test: place a dollar bill between the stove and
door and then shut the door. If you can pull the
dollar out, remove one washer from door handle
behind latch cam and try again. If you can still
pull it out, replace the door gasket.
Door & Glass Assemblies
WEEKLY
or
After Every
25 Loads of
Wood
Check the glass frame for loose screws to pre-
vent air leakage. Check glass for cracks.
Door Handle
Check the door latch for proper adjustment.
This is very important especially after the door
rope has formed to the stove face.
WEEKLY
or
After Every 25
Loads of Wood
Latch Cam
Spacing Washers
Check door handle for smooth cam operation.
Note: These are generic drawings and may not represent your specific model.
Page 30
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
Troubleshooting Guide
10
With proper installation, operation, and maintenance your woodstove will provide years of trouble-free service. If you do
experience a problem, this troubleshooting guide will assist you or a qualified service person in the diagnosis of a problem
and the corrective action to be taken.
Start Fire Problems
Possible Cause
Solution
Can not get fire started
Excessive smoke or spillage
Burns too slowly
Not enough kindling/paper or no Use dry kindling, more paper. Arrange kindling &
kindling/paper
wood for air movement.
Not enough heat output
Check for restricted termination cap
Check for blockage of outside air kit (if installed).
Check for flue blockage.
Pre-warm flue before starting fire (refer to Building
a Fire Section).
Not enough air for fire to ignite
Check for adequate vent height (refer to Chimney
Height Section).
Open window below the appliance towards the
wind.
Wood condition is too wet, too
large
Use dry, seasoned wood (refer to Seasoned Wood
Section).
Bed of coals not established
before adding wood
Start with paper & kindling to establish bed of
coals (refer to Building a Fire Section).
Flue blockage such as birds’
nests or leaves in termination
cap
Have chimney inspected for creosote and cleaned
by a certified chimney sweep.
Down draft or negative pressure Do not use exhaust fans during start-up (refer to
Competition with exhaust
devices
Negative Pressure Section).
Open window below the appliance towards the
wind.
Fire burns too fast
Mix in hardwood.
Mix in less seasoned wood after fire is established
(refer to Wood Fuel Section).
Extremely dry or soft wood
Overdrafting
Check for correct vent height; too much vertical
height creates overdrafting.
Check location of vent termination (refer to
Chimney Termination Requirement Section).
Page 31
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
Isle Royale
Beginning Manufacturing Date: Sept. 2000
Ending Manufacturing Date: Active
Service Parts
Non-Catalytic, Top-Load,
Wood Stove
823-0170 (Matte Black)
823-0290 (Porcelain Mahogany)
Retired Units
823-0180 (Porcelain Black) (Oct 2000 thru Apr 2002)
823-0190 (Porcelain Creme) (Aug 2000 thru Nov 2005)
823-0200 (Porcelain Green) (Oct 2000 thru Mar 2005)
823-0210 (Porcelain Blue) (Oct 2000 thru Apr 2002)
823-0300 (Porcelain Midnight Blue) (Apr 2002 thru Mar 2003)
823-0301 (Porcelain Midnight Blue) (June 2003 thru Aug 2005)
A. Exploded Drawing
1
5
2
6
7
3
8
4
9
10
11
18
19
17
12
16
14
15
13
Part number list on following page.
Page 32
November 22, 2011
250-5763E
Download from Www.Somanuals.com. All Manuals Search And Download.
Isle Royale
Beginning Manufacturing Date: Sept. 2000
Service Parts
B. Service Parts and Accessories
Ending Manufacturing Date: Active
IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement
parts for your appliance please provide model number and serial number. All parts listed
in this manual may be ordered from an authorized dealer.
Stocked
at Depot
ITEM
DESCRIPTION
COMMENTS
PART NUMBER
434-0670
1
2
3
4
Flue Shield Top
Flue Shield Bottom
Rear Shield
434-0680
434-0500
Flue Transition Assembly
Griddle Tool
7006-019
834-4000
Y
Y
5
Fiber Handle
SRV433-1380
834-4190
6
7
Griddle
Griddle Hinge Stop
434-0440
Black
434-0050MBK
832-3380
8
Top Plate - Must Specify
Mahogany
10 Ft
Gasket, Rope, 1/4”, Field Cut to Size
834-1460
Y
#9 Baffle Assembly
9.1
9.5
9.2
9.3
9.4
9.6
9.7
9
Baffle Assembly
Baffle, Cast
SRV434-5010
434-0110
434-0080
434-0100
834-4080
7000-114
434-0650
834-4040
832-3360
832-0661
434-0370
834-4100
844-8980
434-0450
832-3610
Y
Y
9.1
9.2
9.3
Baffle Control Cam
Lever, Baffle
Gold
9.4
Handle, Baffle
Fiberboard, Baffle
Nickel
9.5
9.6
9.7
Baffle Repair Kit - Left & Right Manifold Chambers
Manifold Tube Set
Y
Y
Manifold Clip/Screws
Baffle Back Plate
Pkg of 4
10
11
12
Grate
Andirons w/Brackets Assembly
Andiron
Qty. 2 req
Andiron Brackets, Pair
Page 33
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
Isle Royale
Service Parts
Beginning Manufacturing Date: Sept. 2000
Ending Manufacturing Date: Active
IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement
parts for your appliance please provide model number and serial number. All parts listed
in this manual may be ordered from an authorized dealer.
Stocked
at Depot
ITEM
DESCRIPTION
COMMENTS
PART NUMBER
#13 Door Assembly
13.9
13.8
13.1
13.2
13.3
13.7
13.4
13.5
13.6
Black
844-9640
13.1
13.2
Door, Left - Must specify color
Mahogany
10 Ft.
844-9650
834-4170
834-3850GD
834-3850NL
SRV433-1380
430-1151
Gasket, Door, 1/2”
Y
Y
Gold
Handle, Replacement Kit
Nickel
13.3
13.4
13.5
Fiber Handle
Key, Cam Latch
Cam Latch
32084
Black
844-9680
844-9690
834-4170
844-5750
433-1590/2
434-5230
834-1460
834-2590
832-0380
29125MBK
29125PMH
SRV434-0300
472-5060
26404MBK
26404PMH
434-0640
434-0460
13.6
Door, Right - Must specify color
Mahogany
10 Ft.
Gasket, Door, 1/2”, Field Cut to Size
Hinge Pin
Y
Y
Y
Y
Y
Gold (pkg of 2)
Nickel (pkg of 2)
13.7
13.8
Glass Assembly - 12” H x 9-1/8” W x 8” H (short side)
Gasket, Rope, 1/4”, Field Cut to Size
Gasket, Lytherm, 1/2X1/8, Field Cut to Size
Glass Tab Set
10 Ft. Length
4.17 Ft. Length
Pkg of 12
13.9
14
Black
Ash Lip
Mahogany
15
Ash Door
Handle, Ash Removal System
Black
16
Leg
Mahogany
17
18
Wear Plate
Brick Retainer
Y
Page 34
November 22, 2011
250-5763E
Download from Www.Somanuals.com. All Manuals Search And Download.
Isle Royale
Service Parts
Beginning Manufacturing Date: Sept. 2000
Ending Manufacturing Date: Active
IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement
parts for your appliance please provide model number and serial number. All parts listed
in this manual may be ordered from an authorized dealer.
Stocked
at Depot
ITEM
DESCRIPTION
COMMENTS
PART NUMBER
#19 Brick Assembly
19.4
19.4
19.5
19.5
19.1
1-1/16"
19.1
8-3/8"
19.3
9"
Ø
1-1/2"
19.5
19.3
19.3
4-1/2"
9"
3-3/4"
19.6
19.7
19.6
19.7
19.8
4-3/4"
19.2
19.2
19.8
4-1/2"
19
Brick Assembly - Complete Set
Brick, 9” x 4.5” x 1.25”
Pkg of 12
834-3860
Y
Y
19.1
19.2
19.3
19.4
19.5
19.6
19.7
19.8
Qty. 2 Req.
Qty. 2 Req.
Qty. 2 Req.
Qty. 2 Req.
Qty. 2 Req.
Qty. 2 Req.
Qty. 2 Req.
Qty. 2 Req.
Pkg of 1
Brick, 7” x 1.25” x 1.25”
Brick, 9” x 4.5” x 1.25” with cut
Brick, 9” x 3.75” x 1.25”
Brick, 9” x 4.5” x 1.25” w/Hole
Brick, 5.25” x 3.5” x 1.25
Brick, 5.25” x 4.5” x 1.25”
Brick, 5.25” X 1.75” x 1.25”
SRV434-0620
832-0550
832-3040
434-0310
434-0330
Brick, Uncut (Must specify size when ordering)
Pkg of 6
Ash Box Hinge
Ash Pan
Blower Cord w/ Speed Control
821-0110
Y
Y
Blower, Convection - Replacement Blower
Bottom Air Channel
812-4900
29134
Black
434-5160
Component Pack Assembly (Includes Owners Manual, Griddle
Handle, Fiber Handle, Warranty Card & Touch-Up Paint)
Mahogany
434-5220
Control System Control Rod
31940
Cover Plate, Blower, Rear Vent
434-7060
Black
434-0470MBK
434-0470PMH
434-0480MBK
434-0480PMH
834-3910
Door Hinge, Left
Mahogany
Black
Door Hinge, Right
Mahogany
Door/Air Control, Upgrade
Page 35
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
Isle Royale
Service Parts
Beginning Manufacturing Date: Sept. 2000
Ending Manufacturing Date: Active
IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement
parts for your appliance please provide model number and serial number. All parts listed
in this manual may be ordered from an authorized dealer.
Stocked
at Depot
ITEM
DESCRIPTION
COMMENTS
PART NUMBER
434-0660
32284/2
Fiberboard, Rear
Knob
Y
Y
Pkg of 2
Latch, Magnet
229-0631
812-0910
855-1450
842-0370
434-5150
Black
Paint Touch-Up
Mahogany
Speed Control Only (Rheostat)
Tool Holder Assembly
Y
ACCESSORIES
Blower Assembly
831-1701
844-7970
844-7980
834-3610
834-3790
210-0230
831-1780
436-7000
33271
Black
Gold
Y
Y
Bracket w/Mitten Rod
Firescreen
Horizontal Flue Kit
Cement, Furnace
Outside Air Kit
3 oz Tube
Y
Y
Front Cover
Outside Air Shield
Rear Channel
436-7020
436-7030
436-7010
7033-039
834-3531
834-4110
Rear Cover Plate
Side Channels
Outside Air Collar Assembly
Black
Warming Shelves
Mahogany
FASTENERS
Avk Rivnut Repair Kit - 1/4-20 & 3/8-16 Rivnut Tools
Bolt, Hex Head, 1/4-20 X 1
RIVNUT-REPAIR
25221A/10
223-0170/20
225-0630/24
220-0440/24
21799A/40
225-0500/40
12460/40
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Pkg of 10
Pkg of 20
Pkg of 24
Pkg of 24
Pkg of 40
Pkg of 40
Pkg of 40
Pkg of 24
Pkg of 3
Bolt, Shoulder, 5/16 X 1/4-20
Screw, Bh, 1/4-20 X 1.25
Screw, Machine Screw 1/4-20 X 5/8
Screw, Pan Head Philips 10-32 X 3/8
Screw, Pan Head Philips 8-32 X 3/8
Screw, Sheet Metal #8 X 1/2 S-Grip
Washer, 1/4 Sae
28758/24
Washer, Sae, 3/8
832-0990
Washer, Teflon
Pkg of 25
844-0460
Page 36
November 22, 2011
250-5763E
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
C. Service And Maintenance Log
Date of Service
Performed By
Description of Service
Page 37
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
D. Warranty Policy
Page 38
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
Isle Royale Wood Stove
Page 39
250-5763E
November 22, 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
R
CONTACT INFORMATION:
Hearth & Home Technologies
1445 North Highway
Colville, WA 99114
Division of HNI INDUSTRIES
Please contact your Quadra-Fire dealer with any questions or concerns.
For the number of your nearest Quadra-Fire dealer,
CAUTION
DO NOT DISCARD THIS MANUAL
•
Read, understand and
follow these instructions
for safe installation and
operation.
•
Leave this manual with
party responsible for
use and operation.
•
Important operating
and maintenance
instructions included.
We recommend that you record the following pertinent
information for your ISLE ROYALE WOOD STOVE
Date purchased/installed:
Serial Number:
Location on appliance:
Dealer phone:
Dealership purchased from:
Notes:
This product may be covered by one or more of the following patents: (United States) 5341794, 5263471, 6688302, 7216645,
7047962 or other U.S. and foreign patents pending.
November 22, 2011
Page 40
250-5763E
Download from Www.Somanuals.com. All Manuals Search And Download.
|
Greenheck Fan Ventilation Hood 470998 User Manual
Grizzly Saw G0728 User Manual
Haier Satellite TV System 29F3A User Manual
Haier Washer Dryer HWM55 10 User Manual
Hamilton Beach Fryer 35033 User Manual
Harbor Freight Tools Doll 94883 User Manual
Harbor Freight Tools Washer 35740 User Manual
Hotpoint Washer Dryer AQD1170F User Manual
Hunter Fan Outdoor Ceiling Fan TypeB User Manual
iHome Clock iH11 User Manual