Microsoft Cluster Installation Documentation
for
HP NetServer LXr 8000 with HP A3661B Model 30/FC
High Availability Disk Array
To assist you in installing your HP NetServer Microsoft Cluster, this file contains the documents
listed below in one pdf file.
•
•
•
Installation Overview - This page provides an overview of the installation steps provided in
the Installation Guide.
Configuration Guide - This guide provides configuration information specific to your cluster
configuration that you will need during installation of your cluster.
HP NetServer Microsoft Cluster Installation Guide - This is the first of two documents used
to install the cluster. It covers the installation of all cluster supported HP NetServers and the
cluster software, and references the Shared Storage Supplement for installation and setup of the
shared storage.
•
Shared Storage Supplement - This supplement is specific to the shared storage device you are
using and must be used with the installation guide. It provides instructions for installing and
setting up your shared storage devices.
13 September 1999
(See next page)
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing a Cluster
“The Big Picture”
How to do it!
(See the referenced
part in the Installation
Guide)
What you will be
doing!
The Overall Tasks
Gather:
Hardware
Gathering Hardware,
Software (Windows NT, NIC drivers, etc.)
IP Addresses, subnet mask, etc.
User names, password, and domain
Tools
1
➮
Software, etc.
What’s Needed
Install components:
into NetServers (i.e., LAN adapters)
into Shared Storage (i.e., drives)
2
NetServers
Configure NetServer and Shared Storage:
Cabling
Switches
Etc.
3
Setting Up Hardware
➮
Shared Storage
4
Cluster
Setup and cable the cluster:
Stack as standalone or racked solution
Connect device cabling
NetServers:
Configure NetServer Hardware and BIOS
Install Windows NT
Install Service Pack
5
NetServers
Shared Storage:
Create disk partitions
Assign Drive Letters
Format logical drives
6
Installing Software
➮
Shared Storage
7
Cluster:
Cluster
Install MSCS
Reinstall Service Pack
Install HotFix (Service Pack 3 only)
Run:
8
Testing
Hardware Verification and Labeling Utility
Cluster Installation Test (CIT)
➮
Test the Cluster
Download from Www.Somanuals.com. All Manuals Search And Download.
This page intentionally left blank.
Download from Www.Somanuals.com. All Manuals Search And Download.
HP NetServer LXr 8000
with
HP A3661B High Availability Disk Array Model 30 / FC
Cluster Configuration Guide
13 September 1999
Introduction
This document defines the supported HP NetServer LXr 8000 and A3661B High Availability Disk Array
Model 30/FC (LXr 8000 / Model 30-FC) configurations for Microsoft Cluster Server. These configurations
minimize single points of failure (SPOF), provide maximum availability, and have been certified by
Hewlett-Packard and Microsoft. This guide is prescriptive; it describes the configurations supported by HP.
Any deviance to these configurations can result in an inoperative cluster or an operating cluster with
degraded performance, hidden SPOFs, etc., and therefore will not be supported by HP.
What’s Defined in a Racked Cluster
Cluster
SPUs
Local and Shared Storage
Intra-cluster and Client LANs
Shared Storage Cabling
Cluster
Type of SPUs
HP NetServer LXr 8000
Each node must be the same model SPU, but may have different clocks
speeds, main memory sizes, cache sizes, and number of CPUs (2, 3, or 4).
Number of nodes
Shared Storage
LANs:
2
See Shared Storage below.
Client LAN
Any NIC that is HP and Microsoft approved. See Client LAN below.
HP D5013A only with crossover cable. See Intra-cluster LAN below.
Intra-cluster
(Heartbeat) LAN
Power source
Direct from power mains, power conditioner or uninterruptible power
supply (UPS) using any power conditioner or UPS.
Download from Www.Somanuals.com. All Manuals Search And Download.
System software:
Navigator version
Operating System
Service pack
L.14.00 or later
Microsoft Windows NT Server 4.0, Enterprise Edition or later
SP3 with hotfix “clusfixi” or later
Single Points of Failure The Model 30/FC Disk Array virtually does not have single points of
(SPOF)
failure. However, care should be taken to bind LUNs as described in the
Model 30/FC Disk Array manual. The manual addresses topics such as;
spreading LUNs equally across internal buses and using RAID modes. In a
cluster configuration, single points of failure arise due to the method used
to connect the disk array to the server. These single points of failure are as
follows:
•
Due to Windows NT inability to allow for dual data paths, a total
fibre-channel hub failure (removal of power from the hub, catastrophic
failure of multiple hub ports) will result in the loss of the cluster. It is
possible to power the hub using an UPS to remove part of the issue,
however an unforeseen total hub failure would still be a single point of
failure. Current data on the fibre channel hub indicates that risk in this
area is minimal.
•
•
If the data connection between the hub and Model 30/FC Disk Array
is broken the cluster will go down. The fibre channel cables are
generally known to be robust with an insignificant possibility of
failure.
A failure in the storage processor of the Model 30/FC Disk Array will
result in a loss of the cluster. The possibility of the storage processor
failing is small. Current configurations do not allow for failover to
another storage processor in the Windows NT environment.
SPU
Model
HP NetServer LXr 8000
Clock speed
No. of CPUs
BIOS version
CPU cache
RAM
400 MHz. or higher
2 – 4
Release 1 or later
Any size
256 MB minimum. Must be HP.
3
No. of power supplies
Local storage
Internal or external, using any controller except NetRAID 1 or 3. Must use
HP disks. See Local Storage below.
I/O slots:
P3 – P4 Shared storage controller
P1 – NetRAID local storage
P5 – Intra-cluster (Heartbeat) LAN
P6 – Client LAN
All others – Any other plug-in cards.
2
Download from Www.Somanuals.com. All Manuals Search And Download.
Storage
Local
Physical drive location
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/8 or /12)
Disk drives
Controller
Must be HP
SPU embedded controller or any controller, any number, manufacturer or
driver in I/O slot P1 for NetRAID local storage (except NetRAID 1 or 3).
See SPU I/O slots above.
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed
Shared Storage
Host Bus Adapter:
Model
A5246A HP Fibre Channel Adapter Kit for NT
1 – 2. (See Shared Storage Configurations.)
2.xx
No. of HBA
Driver
SPU I/O slot
Disk Array Controller:
Model
P3 (1st HBA) and P4 (2nd HBA)
SP630/FC Storage Processor (ordered with A3661B or A3662B)
1 – 2. (See Shared Storage Configurations.)
9.45.03 or greater
No. of controllers
Microcode
Disk Array Storage:
Model
A3661B HP High Availability Disk Array Model 30/FC.
See Shared Storage Configurations.
1 – 2. (See Shared Storage Configurations.)
4 GB, 8.8 GB, 17.8 GB
No. of cabinets
Controller
Disk capacities:
ArrayGUIde
RAID levels
Logical units
Hot spares
Version 1.7.0 or greater
1, 1/0, 3 and 5
Logical units within each array must be numbered from 0 – 7.
Recommend assigning logical unit numbers 8 or greater
3
Power Supply
RAID arrays
Different size or speed disks are allowed in the same RAID array but
are not recommended in the same logical unit.
Shared Storage Cables (Fiber Optics)
Cables for the Short Wave
Port of either a Short or
Long Wave Hub
A3583A 2 meter FC cable,
A3531A 16 meter FC cable,
A3735A 50 meter FC cable,
A3736A 100 meter FC cable,
Any cable ≤500 meters per segment that conforms to ANSI X3.230-
1994 Fibre Channel Standards Specification (FC-PH) rev 4.3.
Cables for the Long Wave
Port of a Long Wave Hub
Any cable ≤2 kilometers that meets ANSI X3.230-1994 Fibre Channel
Standards Specification (FC-PH) rev 4.3.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Shared Storage Configurations
Configurations:
Basic
See "Basic Configuration Cabling Diagrams with Single or Cascaded
Hubs."
Redundant
See "Redundant Configuration Cabling Diagrams with Single or
Cascaded Hubs."
Fibre Channel Hubs:
Model
A3724A HP 10-port Short Wave Fibre Channel (FC) Hub
A4839A HP 10-port Long Wave FC Hub
No. of Hubs
Basic Configuration: 1 or 2
Redundant Configuration: 2 or 4 with 1 min. or 2. max. per FC
Arbitrated Loop.
Disk Arrays (See Shared
Storage.):
No. of Disk Arrays
No. of Controllers
1-8
1 per Disk Array for Basic Configuration.
2 per Disk Array for Redundant Configuration.
LANs
Intra-cluster (Heartbeat) LAN
Client LAN
LAN connection
HP D5954A crossover cable or any
equivalent
Any LAN
The intra-cluster LAN may only be used for
cluster node communication via a crossover
cable. It may not be used for client
communication.
NIC:
Model
HP D5013A (10/100TX PCI)
Any that is on both the HP
Tested Products List and the
Microsoft Hardware
Compatibility List.
Driver
3.27.00.0001 or later (Do not enable FEC
Features.)
Any driver
NOTE: If the NIC used is the
same as the Intra-cluster LAN,
then the Client LAN must use the
same driver as the Intra-cluster
LAN.
No. of NICs
SPU I\O slot
1
1 minimum
P6
P5
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Shared Storage Cabling
This part of the guide defines the allowable cabling configurations for clusters using the HP NetServer
LXr 8000 and High Availability Disk Array Model 30/FC. Only these cabling configurations and cables
are supported.
See Shared
Storage Cables for
a list of cables that
can be connected
to the Short Wave
Ports of the hub.
Port connections to this
hub are for example
only. You can use any
port, except for port 10
on Long Wave Hubs.
The remaining ports can
be used for connection
of additional Disk Arrays.
Basic Configuration with Single Fibre Channel Arbitrated Loop Hub
5
Download from Www.Somanuals.com. All Manuals Search And Download.
See Shared
Storage Cables for
a list of cables that
can be connected
to the Short Wave
Ports of the hub.
See Shared Storage
Cables for a list of
cables that can be
connected between
hubs. Port 10 is used
exclusively in Long
Wave hubs for hub-to-
hub connection.
Port connections to
these hubs are for
example only. You can
use any port, except for
port 10 on Long Wave
Hubs. The remaining
ports can be used for
connection of additional
Disk Arrays.
Basic Configuration with Cascaded Fibre Channel Arbitrated Loop
Hubs
6
Download from Www.Somanuals.com. All Manuals Search And Download.
See Shared
Storage Cables for
a list of cables that
can be connected
to the Short Wave
Ports of the hub.
Port connections to
these hubs are for
example only. You can
use any port, except for
port 10 on Long Wave
Hubs. The remaining
ports can be used for
connection of additional
Disk Arrays.
Redundant Configuration with Single Fibre Channel Arbitrated Loop Hub
7
Download from Www.Somanuals.com. All Manuals Search And Download.
See Shared
Storage Cables for
a list of cables that
can be connected
to the Short Wave
Ports of the hub.
See Shared
Storage Cables for
a list of cables that
can be connected
between hubs.
Port connections to
these hubs are for
example only. You
can use any port,
except for port 10 on
Long Wave Hubs. The
remaining ports can
be used for
Port 10 is used
exclusively in Long
Wave hubs for hub-
to-hub connection.
connection of
additional Disk Arrays.
Redundant Configuration with Cascaded Fibre Channel Arbitrated Loop Hubs
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Version History
13 September 1999
In Cluster specifications added a description of "Single Points Of Failure
(SPOF) to clarify this property of the cluster.
21 April 1999
CPU speed was "400 MHz and higher" is "400 and 450 MHz only."
Initial release.
12 January 1999
9
Download from Www.Somanuals.com. All Manuals Search And Download.
This page intentionally left blank.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
HP NetServer
Microsoft Cluster Installation Guide
with
Shared Storage System Supplement
Rack Storage/12FC
Rack Storage/12
Rack Storage/8
Storage System/6
HP AutoRAID Disk Array Model 12H
or
HP A3661B Model 30/FC High Availability Disk Array
1 September 1999
(See Version History below)
Download from Www.Somanuals.com. All Manuals Search And Download.
This page intentionally left blank.
HP NetServer Installation Guide
2
Download from Www.Somanuals.com. All Manuals Search And Download.
Notice
The information in this document is subject to change without notice.
Hewlett-Packard makes no warranty of any kind with regard to this material, including, but not limited to, the
implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be
liable for errors contained herein or for incidental or consequential damages in connection with the
furnishing, performance, or use of this material. Hewlett-Packard assumes no responsibility for the use or
reliability of its software on equipment that is not furnished by Hewlett-Packard.
Warranty
If you have any questions about the warranty for this product, contact your dealer.
Safety Considerations
The product and related documentation must be reviewed for familiarization with safety markings and
instructions before installation and operation.
Safety Symbols
A WARNING denotes a hazard that can cause personal injury.
A CAUTION denotes a hazard that can damage equipment or result in lost data.
A NOTE contains information that is useful in accomplishing a task and should be read
before performing the associated instruction(s).
Do not proceed beyond a WARNING or CAUTION notice until you understand the hazardous conditions
and have taken appropriate steps.
Grounding
The computer in which this product is installed is a safety class I product and has a protective earthing
terminal. There must be an uninterruptible safety earth ground from the main power source to the product’s
input wiring terminals, power cord, or supplied power cord set. Whenever it is likely that the protection has
been impaired, disconnect the power cord until the ground has been restored.
Servicing
Any service, adjustment, maintenance, or repair must be performed only by authorized service-trained
personnel.
Trademark Notice
This document contains proprietary information that is protected by copyright. All rights are reserved. No
part of this document may be photocopied, reproduced, or translated to another language without the prior
written consent of Hewlett-Packard Company.
The use of trademarks or other designations is for reference purposes only. The following trademarks are
used in this manual:
•
•
•
Microsoft and MS-DOS are U.S. registered trademarks of Microsoft Corp.
Windows and Windows NT are trademarks of Microsoft Corporation.
3M is a registered Trademark of the 3M Company.
Hewlett-Packard
Network Server Division
10955 Tantau Avenue
Cupertino, CA 95014-0770, USA
© Copyright 1999, Hewlett-Packard Company
HP NetServer Installation Guide
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Some topics in this guide are applicable to all HP NetServer clusters while others are HP NetServer and
shared storage specific. A complete installation guide consists of two documents: this document (common to
all HP NetServers) and the supplement for your shared storage system.
OVERVIEW................................................................................................................................................... 5
VERSION HISTORY....................................................................................................................................... 5
INTENDED AUDIENCE .................................................................................................................................. 5
A GRAPHICAL OVERVIEW TO SETTING UP THE CLUSTER ............................................................................ 6
1
WHAT’S NEEDED................................................................................................................................... 7
NEED MORE HELP?...................................................................................................................................... 8
REFERENCED DOCUMENTS .......................................................................................................................... 8
2
NETSERVER HARDWARE SETUP ..................................................................................................... 9
INSTALL COMPONENTS ................................................................................................................................ 9
SHARED STORAGE HARDWARE SETUP....................................................................................... 10
3
4
CLUSTER CABLING AND SETUP..................................................................................................... 11
SETUP CLUSTER HARDWARE ..................................................................................................................... 11
CONNECT THE LAN ADAPTERS................................................................................................................. 11
CONNECT SHARED STORAGE & CABLE THE CLUSTER............................................................................... 11
5
NETSERVER SOFTWARE SETUP..................................................................................................... 12
START HERE .............................................................................................................................................. 12
LCII........................................................................................................................................................... 12
LC3 ........................................................................................................................................................... 13
LH PRO ..................................................................................................................................................... 14
LH 3 .......................................................................................................................................................... 15
LH 3 (WITH NETRAID LOCAL AND SHARED STORAGE) ........................................................................... 17
LH 4 .......................................................................................................................................................... 19
LPR............................................................................................................................................................ 21
LPR (WITH NETRAID LOCAL AND SHARED STORAGE)............................................................................. 23
LX/LXR PRO ............................................................................................................................................. 25
LXR 8000 .................................................................................................................................................. 26
LXR 8000 (WITH FIBRE CHANNEL)............................................................................................................ 28
INSTALL SERVICE PACK FOR ALL HP NETSERVERS .................................................................................. 29
6
7
SHARED STORAGE SOFTWARE SETUP........................................................................................ 31
SHARED STORAGE SETUP .......................................................................................................................... 31
CREATE THE ARRAY FILE SYSTEMS........................................................................................................... 31
MICROSOFT CLUSTER SERVER SOFTWARE SETUP................................................................ 37
INSTALL MSCS ON SYSTEM A................................................................................................................... 37
INSTALL MSCS ON SYSTEM B................................................................................................................... 41
INSTALL SERVICE PACK OR HOT FIX ......................................................................................................... 41
8
CLUSTER TESTING............................................................................................................................. 42
HARDWARE VERIFICATION AND LABELING UTILITY ................................................................................. 42
CLUSTER INSTALLATION TEST................................................................................................................... 42
HP NetServer Installation Guide
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Overview
HP NetServer clusters provide increased availability solutions for critical applications. The basic cluster
consists of two HP NetServer systems coupled to shared storage units. The operating system files, application
files, and other files local to each node are stored on fixed or hot swap disks. Local disks are usually located
internally in the system.
Both HP NetServers share external drives located in the shared storage unit(s). Shared drives are accessed
using an interface card (typically referred to as the Host Bus Adapter) located in each HP NetServer unit.
Both HP NetServers run Microsoft Windows NT Server, Enterprise Edition, which includes Microsoft
Cluster Server software.
This guide has been designed to help you setup the HP NetServers, set up, assemble and cable the cluster,
and install server and cluster software.
NOTE
This installation guide is incomplete without the supplement specific to your shared
storage system. When directed by this guide, turn to the supplement to get the necessary
instructions.
Version History
Date
Change
1 September 99
Added installation instructions f or a fibre channel cluster solution using the LXr 8000
with the Rack Storage/12FC and up to two optional Rack Storage/12s.
7 April 99
8 March 99
Corrected error (changed LHI to LH4 two places in the LH4 install procedures).
Simplified the overall installation procedure by removing the need to match drive letters
for the second node.
Added instructions for the LPr, using NetRAID local and shared storage and Revised
instructions to use Navigator L.15.05 on LH4, LPr, and LXr 8000.
19 Jan. 99
18 Dec. 98
20 Nov. 98
Added installation instructions for the LPr.
Added installation procedures for the HP NetServer LH 4 and LXr 8000.
Revised the LH3 installation procedures in part 5 to allow using LH3 clusters with
Model 12H and FC-30 shared storage subsystems.
5 Oct. 98
Revised part 5 – Installation to provide separate server configuration and Windows NT
installation procedures. Added the LH3 installation procedure including using a
NetRAID adapter for local storage.
20 July 98
9 June 98
Added installation instructions in part 5 for the LC3.
Initial release
Intended Audience
The guide is for the person who installs, administers, and troubleshoots the Microsoft Cluster Server.
Hewlett-Packard assumes this person is qualified to service computer equipment and trained to recognize
hazards in products with hazardous energy levels.
NOTE
Hewlett-Packard only supports and recommends installation of clustered HP NetServer
systems using Microsoft Cluster Server software by a Microsoft or HP Cluster Certified
Installer.
HP NetServer Installation Guide
5
Download from Www.Somanuals.com. All Manuals Search And Download.
A Graphical Overview to Setting Up the Cluster
CAUTION
Departing from the sequence shown here can cause unnecessary work and unpredictable
results.
HP NetServer Installation Guide
6
Download from Www.Somanuals.com. All Manuals Search And Download.
1 What’s Needed
Before beginning the installation, make sure you have the following items prepared and tools and resources
available.
Some information in this part is shared storage specific. See part "1 What’s Needed" of the
Shared Storage Supplement and the Configuration Guide for your cluster. Review the
supplement, refer to the Configuration Guide as directed, then return to this part.
Addresses / Names
•
Minimum of three Client LAN IP addresses: one for each HP NetServer system and one for the HP
NetServer cluster client LAN.
•
Two Intra-cluster LAN IP addresses for the intra-cluster LAN: One for each HP NetServer system.
(May use hidden or intranet addresses. See the MSCS Administrator’s Guide for a discussion of IP
addressing.)
NOTE
The Client LAN IP address and Intra-cluster LAN IP addresses must be on different
subnets.
•
•
•
Cluster and node names (limited to 15 or fewer alphanumeric characters)
Subnet mask
User name, password, and domain to be used for the cluster service.
Hardware
Compare the hardware you have received with your ordering documentation, such as the parts lists created by
HP NetServer Order Assistant and Rack Assistant
Software
•
Microsoft Windows NT Server (Enterprise Edition), version 4.0, which includes Windows NT, version
4.0 and Service Pack (SP). See the Configuration Guide for your cluster solution for the applicable
Windows NT and SP versions and Microsoft Cluster Server installation software.
NOTE
Some HP NetServers, as stated in part “5 NetServer Software Setup,” require installing
Windows NT from floppy disks. To create floppy disks, on a computer running Windows
95 or NT, insert the Windows NT Server/E base CD in the CDROM drive and from the
commDnd line execute: D:\i386\winnt32.exe /ox. If needed, see, “How to Create
Windows NT Boot Floppy Disks” under Support Online for the Microsoft web site.
•
Microsoft Hotfix (clusfixi.exe) for Windows NT (for SP3 only). This software is only needed if you
are using Service Pack 3. To download.
2. On the site navigator bar, select SEARCH, then search for Q147222 in the "Support & Knowledge
Base" category.
3. On the Search Results page, select Group of Hotfixes for Exchange 5.5 and IIS 4.0, then follow the
ftp path to download the "clusfixi.exe" file.
HP NetServer Installation Guide
7
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTE
When performing this search on the Microsoft web site you may be prompted to register
with Support Online. If prompted to register, you must first complete the questionnaire
and then complete the search.
•
•
•
HP NetServer Navigator CD. HP recommends you use the latest version, however you may use an
earlier version if it is specified in the Configuration Guide for your cluster.
Cluster Installation Test. Downloaded from the Certified Installer Corner under Install & Configure
on the HP NetServer Clustering Solutions web site.
NIC drivers. Download HP drivers from Software Downloads page under Install & Configure" on the
HP NetServer Clustering Solutions web site.
Tools
Common hand tools plus the following:
•
Torx™ T-25 driver supplied in the Rack Installation Toolkit. For rack installed clusters only.
Portable Field Service Grounding Kit (3M® part number 8505, or equivalent).
•
Need More Help?
HP Information Assistant provides extensive support information and is available on the HP NetServer
Online Documentation CD-ROM. Although you can access HP Information Assistant from the NetServer
Navigator Main menu, HP recommends that you install it on an available Windows client connected to a
printer. For more information about installing HP Information Assistant, refer to the system documentation.
The following reference materials may also be useful:
•
•
HP NetServer Microsoft Windows NT 4.0 Installation Guide for your HP NetServer
Processor Upgrade Instructions
These materials are available by choosing Install or Reference Books on the HP Information Assistant's Main
menu.
Referenced Documents
•
MSCS Administrator's Guide on the Microsoft NT 4.0 base CD under \Support\Books
•
HP NetServer Configuration Guide. If not bundled with this Installation Guide downloaded from the
Supported Configurations page under Plan on the HP Cluster Solutions web site
HP NetServer Installation Guide
8
Download from Www.Somanuals.com. All Manuals Search And Download.
2 NetServer Hardware Setup
When HP NetServers are shipped from the factory, they are configured for stand-alone operation. The first
step in creating a cluster is to install additional hardware that allows the HP NetServers to:
•
•
•
Share data
Communicate with one another
Communicate with the LAN
CAUTION
Installing hardware requires opening the HP NetServers. HP therefore, recommends
using a grounding kit. See part "1 What’s Needed" for details. The kit contains a wrist
strap, anti-static mat, and cable.
Install Components
NOTE
Perform the following procedure on either HP NetServer first, and then repeat the
procedure for the second NetServer.
1. Gather the required hardware components for the HP NetServers and separate the components into two
systems.
2. Remove the HP NetServer cover(s).
3. Install any of the following types of components that were supplied with your HP NetServers using the
instructions supplied with each component. If needed, refer to HP Information Assistant for additional
instructions:
•
•
Processors. If additional processors were supplied with your HP NetServers install them at this time.
Main Memory. Cluster operations require a minimum amount of main memory (RAM). Typically
you do not need to add memory to your HP NetServers. However, if additional memory is required,
it will be identified by the HP Order Assistant program and will be supplied. Install any additional
memory that has been provided with your order. See the Configuration Guide for your cluster
configuration and check that you meet the minimum memory requirements.
•
LAN Adapters. Install two LAN adapters in each HP NetServer. Refer to the HP NetServer
Configuration Guide for your cluster and install the adapters in the PCI slots stated in the guide. If
other boards are installed in these slots, remove them and install them in other slots.
•
•
•
Internal Disks. If provided install the local storage drives (fixed or hot swap) into the HP
NetServers.
Local Storage Adapter. This adapter provides the interface to the local storage of the node. See
the Configuration Guide for your cluster configuration for the PCI slot to use.
Host Bus (Shared Storage) Adapters. These adapters provide the interface to the Shared Storage
Systems and must be installed in specific PCI slots. See the Configuration Guide for your cluster
configuration for the HP NetServer PCI slots to use.
See instructions supplied with the component or see part "2 NetServer Hardware Setup" of
the Shared Storage Supplement for instructions on installing these adapters.
HP NetServer Installation Guide
9
Download from Www.Somanuals.com. All Manuals Search And Download.
3 Shared Storage Hardware Setup
part "3 Shared Storage Hardware Setup" in the Shared Storage Supplement
HP NetServer Installation Guide
10
Download from Www.Somanuals.com. All Manuals Search And Download.
4 Cluster Cabling and Setup
Setup Cluster Hardware
Non-racked clusters - Follow the Site Preparation guidelines provided in the Planning Guide under Plan on
the HP NetServers Clustering Solutions web site.
Racked clusters - Follow the Road Map supplied with the system and instructions in the shared storage
supplement. In addition you should have rack layouts of your system printed from the HP NetServers Rack
Assistant program. If not, see HP NetServers web site to download this program.
Connect the LAN Adapters
Two sets of LAN adapters need to be connected. One set allows the cluster to communicate node-to-node
over what is typically called the intra-cluster LAN. The second set allows the cluster to communicate with
external clients over what is typically called the client LAN.
NOTE
See the Configuration Guide for your cluster for the PCI slots to be used for the intra-
cluster and client LANs.
To connect the cluster’s LAN adapters:
1. Connect the intra-cluster LAN adapter in one node to the intra-cluster LAN adapter in the other node
using a crossover cable.
2. Connect the client LAN adapter in each node to the client LAN using Ethernet cables.
Connect Shared Storage & Cable the Cluster
part "4 Cluster Cabling and Setup" in the Shared Storage Supplement
HP NetServer Installation Guide
11
Download from Www.Somanuals.com. All Manuals Search And Download.
5 NetServer Software Setup
Follow the procedures in this part to configure the hardware and BIOS and to install Windows NT including
the applicable Service Pack.
Start Here
In this part you will perform two major tasks. First you will configure the NetServer Hardware and BIOS
and Install Windows NT following a procedure specific to your HP NetServer as listed below. Secondly, you
will install the applicable Service Pack on the NetServer. Select your procedure from the following list:
You will…
Go to procedure for…
On page …
LCII
LC3
LH Pro
LH 3
12
13
14
15
17
19
21
25
27
28
28
30
LH 3 (with NetRAID local storage)
LH 4
LPr
LPr (with NetRAID local and shared storage)
LX/LXr Pro
LXr 8000
LXr 8000 (with fibre channel)
Installing the Microsoft Service Pack
First
Second
LCII
Configure NetServer Hardware and BIOS
1. Make sure you power down System A and power up System B.
2. Insert the HP NetServer Navigator CD in the CD-ROM drive of System B and restart the server.
The server boots from the CD and displays the Navigator Main menu.
NOTE
If prompted that the HP NetServer Navigator BIOS is a newer version, choose
Continueand go to step 3; otherwise go to step 6.
3. To update the BIOS, choose Configuration Assistant, then Custom, Microsoft, NT 4.0,
and Nofor automated NOS installation.
4. Select Update, then Execute. Follow screen prompts to update the BIOS.
5. After the server reboots return to the Navigator main menu by clicking the Back button twice on the
displayed window.
6. Install a utilities partition on the local storage disk by choosing Configuration Assistant, then
Custom, Microsoft, MS Windows NT 4.0 Enterprise Edition, and Nofor automated
NOS installation.
7. Choose Install/Update Utility Partition.
When finished, the system reboots and displays the Custom Configuration window.
HP NetServer Installation Guide
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Install Windows NT
1. Remove the HP NetServer Navigator CD, insert the first CD of the Microsoft Windows NT Server,
Enterprise Edition, and exit Navigator to reboot the server.
2. Select the following options when prompted:
•
•
•
Choose the unpartitioned space and install Windows NT.
Choose NTFS file system.
When prompted to search for a Network Adapter, load NIC drivers for both the intra-cluster and the
client LAN. Be sure to load the correct intra-cluster LAN driver version as specified in the
Configuration Guide for your cluster. If you are using two HP D5013A NICs, load the driver twice,
once for the intra-cluster NIC and once for the client NIC.
•
Make sure TCP/IP Protocolis selected.
Other protocols may be selected in addition, but TCP/IP is required.
•
Set TCP/IP Properties for DNS, WINS Address, etc. at this time.
NOTE
The Client LAN IP addresses and Intra-cluster LAN IP addresses must be on different
subnets.
LC3
Configure NetServer Hardware and BIOS
1. Make sure you power down System A and power up System B.
2. Insert the HP NetServer Navigator CD in the CD-ROM drive of System B and restart the server.
The server boots from the CD and displays the Navigator Main menu.
NOTE
If prompted that the HP NetServer Navigator BIOS is a newer version, choose
Continueand go to step 3; otherwise go to step 6.
3. To update the BIOS, choose Configuration Assistant and Installation Assistant,
then Custom, Microsoft, NT 4.0and Nofor automated NOS installation.
4. Select Update, then Execute. Follow screen prompts to update the BIOS.
5. After the server reboots return to the Navigator main menu by clicking the Back button twice on the
displayed window.
6. Install a utilities partition on the local storage disk by choosing Configuration Assistant and
Installation Assistant, then Custom, Microsoft, MS Windows NT 4.0 Enterprise
Edition, and Nofor automated NOS installation.
7. Choose Install/Update Utility Partition.
When finished, the system reboots and displays the Custom Configuration window.
HP NetServer Installation Guide
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Install Windows NT
1. Remove the HP NetServer Navigator CD, insert the first CD of the Microsoft Windows NT Server,
Enterprise Edition, and exit Navigator to reboot the server.
2. Select the following options when prompted:
•
•
•
Choose the unpartitioned space and install Windows NT.
Choose NTFS file system.
When prompted to search for a Network Adapter, load NIC drivers for both the intra-cluster and the
client LAN. Be sure to load the correct intra-cluster LAN driver version as specified in the
Configuration Guide for your cluster. If you are using two HP D5013A NICs, load the driver twice,
once for the intra-cluster NIC and once for the client NIC.
•
Make sure TCP/IP Protocolis selected.
Other protocols may be selected in addition, but TCP/IP is required.
•
Set TCP/IP Properties for DNS, WINS Address, etc. at this time.
NOTE
The Client LAN IP addresses and Intra-cluster LAN IP addresses must be on different
subnets.
LH Pro
1. Make sure you power down System A and power up System B.
2. Insert the HP NetServer Navigator CD in the CD-ROM drive of System B and restart the server.
The server boots from the CD and displays the Navigator Main menu.
NOTE
If prompted that the HP NetServer Navigator BIOS is a newer version, choose
Continueand go to step 3; otherwise go to step 6.
3. To update the BIOS, choose Configuration Assistant, then Custom, Microsoft, MS
Windows NT 4.0 Enterprise Edition, and Nofor automated NOS installation.
4. Select Update, then Execute. Follow screen prompts to update the BIOS.
5. After the server reboots return to the Navigator main menu by clicking the Back button twice on the
displayed window.
6. From the Navigator Main menu, choose NetServer Utilities, then EISA Configuration
Utility.
7. In the EISA Configuration Utility, disable the Embedded IDE Hard Disk Controller.
(The embedded IDE controller is not used on HP NetServer systems.)
8. Save and exit the EISA Configuration Utility.
The Utility saves your configuration data, restarts the HP NetServer and reloads the HP Navigator CD-
ROM.
9. Install a utility partition on the local storage disk by choosing Configuration Assistant, then
Custom, Microsoft, MS Windows NT 4.0 Enterprise Edition, and Nofor automated
NOS installation.
10. Choose Install/Update Utility Partition.
When finished, the system reboots and displays the Custom Configuration window.
HP NetServer Installation Guide
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Install Windows NT
1. Remove the HP NetServer Navigator CD, insert the first CD of the Microsoft Windows NT Server,
Enterprise Edition, and exit Navigator to reboot the server.
2. Select the following options when prompted:
•
•
•
Choose the unpartitioned space and install Windows NT.
Choose NTFS file system
When prompted to search for a Network Adapter, load NIC drivers for both the intra-cluster and the
client LAN. Be sure to load the correct intra-cluster LAN driver version as specified in the
Configuration Guide for your cluster. If you are using two HP D5013A NICs, load the driver twice,
once for the intra-cluster NIC and once for the client NIC.
•
Make sure TCP/IP Protocol is selected.
Other protocols may be selected in addition, but TCP/IP is required.
•
Set TCP/IP Properties for DNS, WINS Address, etc. at this time.
NOTE
The Client LAN IP addresses and Intra-cluster LAN IP addresses must be on different
subnets.
LH 3
These procedures provide instructions for servers using NetRAID, AutoRAID Model 12H, and Model 30/FC
shared storage solutions.
NOTE
If you are use NetRAID adapters for both shared and local storage go to the next
procedure, LH3 (with NetRAID Local and Shared Storage) on page 17.
Configure NetServer Hardware and BIOS
1. Make sure you power down System A and power up System B.
2. Insert the HP NetServer Navigator CD in the CD-ROM drive and restart the server.
3. During reboot enter the Setup Utility by pressing F2.
4. Select User Preferencesand then the LH4 Integrated NetRAIDsetting you want to use.
If you are using NetRAID for shared storage, disable the LH4 Integrated HP NetRAID.
It must be disabled otherwise it will conflict with the HP NetRAID adapter used for shared storage.
5. Exit the Setup Utility.
The server reboots. If you have special NetServer local SCSI bus options enter the Symbios utility, by
pressing Ctrl+C at the Symbios boot banner during reboot and set the options you need; otherwise allow
the server to reboot. The server boots from the CD and displays the Navigator Main menu.
NOTE
If prompted that the HP NetServer Navigator BIOS is a newer version, choose
Continueand go to step 6; otherwise go to step 9.
6. To update the BIOS, choose Configuration Assistant and Installation Assistant,
then Custom, Microsoft, MS Windows NT 4.0 Enterprise Edition, and Nofor
automated NOS installation.
7. Select Update, then Execute. Follow screen prompts to update the BIOS.
HP NetServer Installation Guide
15
Download from Www.Somanuals.com. All Manuals Search And Download.
8. After the server reboots, return to the Navigator main menu by clicking the Back button twice on the
displayed window.
9. From the Navigator main menu, install a utility partition on the local storage disk by choosing
Configuration Assistant and Installation Assistant, then Custom,
Microsoft, MS Windows NT 4.0 Enterprise Edition, and Nofor automated NOS
installation.
10. Choose Install/Update Utility Partition.
When finished, the system reboots and displays the Custom Configuration window.
11. Make an NT 4.0 Drivers disk by choosing Create Driver Diskette(s),Execute,and
following the prompts. Label the floppy disk NT 4.0 Drivers.
Install Windows NT
NOTE
Windows NT must be installed from floppy disks, not the CD, so that the mass storage
drivers will be loaded correctly. If you have not created a set of Windows NT boot
floppy disks, see Software in part “1 What’s Needed” for additional information.
1. Remove the HP NetServer Navigator CD, insert the boot floppy for Windows NT4.0, and exit Navigator
to reboot the server.
2. When Setup prompts to detect mass storage devices, skip detection and manually specify the mass
storage drivers:
•
•
The drivers are loaded from the NT 4.0 Drivers floppy disk you created from the Navigator CD.
First, load the driver for the device you want to boot from. For drives in the LH 3 internal bays this
will normally be the embedded SCSI Symbios driver.
•
•
Secondly, load the IDE driver, since the CD drive is on the IDE bus.
Finally, load any other mass storage drivers you need. If you are using NetRAID for shared storage
do not load the HP NetRAID driver at this time. It will be loaded later.
3. Continue the installation, inserting floppy disks #2 and #3 and select the following options when
prompted:
•
•
•
Choose the unpartitioned space and install Windows NT.
Choose NTFS file system
When prompted to search for a Network Adapter, load NIC drivers for both the intra-cluster and the
client LAN. Be sure to load the correct intra-cluster LAN driver version as specified in the
Configuration Guide for your cluster. If you are using two HP D5013A NICs, load the driver twice,
once for the intra-cluster NIC and once for the client NIC.
•
•
Make sure TCP/IP Protocolis selected.
Other protocols may be selected in addition, but TCP/IP is required.
If you are using two HP D5013A NICs, when prompted for TCP/IP Properties:
Make sure adapter [2] is highlighted and specify its IP address and subnet mask. This will be the
LAN adapter for the intra-cluster LAN.
Select adapter [1] and specify its IP address and subnet mask. This will be the LAN adapter for the
client LAN.
Set TCP/IP Properties for DNS, WINS Address, etc. at this time.
HP NetServer Installation Guide
16
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTE
The Client LAN IP addresses and Intra-cluster LAN IP addresses must be on different
subnets.
4. Once the NT installation is complete, the D5013A NIC drivers must be manually set to the correct LAN
speed. Log on and from the start menu select: Settings, Control Panel, Network, and
Adapters. For each D5013A adapter, select Propertiesthen Settingsand set the network
speed to the appropriate setting (either 10 Mbps or 100 Mbps) for your network. The intra-cluster LAN
should be set to 100 Mbps. Do not use the Auto setting.
LH 3 (with NetRAID Local and Shared Storage)
A NetRAID adapter may only be used for either shared storage or local storage; one adapter may not be used for
both. To use NetRAID adapters for both shared and local storage, you must use two adapters.
Configure NetServer Hardware and BIOS
1. Make sure you power down System A and power up System B.
2. Insert the HP NetServer Navigator CD in the CD-ROM drive and restart the server.
3. During reboot enter the Setup Utility by pressing F2.
4. Using the Setup Utility disable the LH3 Integrated NetRAID.
Integrated NetRAID is not used in a cluster because it conflicts with the HP NetRAID adapter used for
shared storage.
NOTE
Auto IRQ assignments can give IRQ conflicts. If this occurs manually set the IRQ
assignments. In Configuration, PCI Slot Devices, PCI IRQLocking,
assign the IRQs to the cards. The following assignments work for the standard
configuration:
Card
NIC
PCI Slot
P1
IRQ
9
NIC
P2
9
NetRAID
P7
5
NetRAID
P8
5
-
-
SCSI A
SCSI B
10 (or disabled)
10 (or disabled)
Disable SCSI A and SCSI B if they are not used!
Set any other options as you desire.
5. Exit the Setup Utility
The server reboots. If you have special NetServer local SCSI bus options enter the Symbios utility, by
pressing Ctrl+C at the Symbios boot banner during reboot and set the options you need; otherwise allow
the server to reboot. The server boots from the CD and displays the Navigator Main menu.
NOTE
If prompted that the HP NetServer Navigator BIOS is a newer version, choose
Continueand go to step 6; otherwise go to step 9.
6. To update the BIOS, choose Configuration Assistant and Installation Assistant,
then Custom, Microsoft, MS Windows NT 4.0 Enterprise Edition, and Nofor
automated NOS installation.
7. Select Update, then Execute. Follow screen prompts to update the BIOS.
8. After the server reboots, return to the Navigator main menu by clicking the Back button twice on the
displayed window.
HP NetServer Installation Guide
17
Download from Www.Somanuals.com. All Manuals Search And Download.
9. From the Navigator main menu select, Configuration Assistant, then Custom, Microsoft,
MS Windows NT 4.0 Enterprise Edition, and No.Check the advisories in Configuration
Advisor for IRQ conflicts and other problems. Click Continue.
10. Define the local storage RAID arrays. Select Configure Disk Arrayand use HP NetRAID
Assistant to define the arrays. Be sure to define the arrays for the local storage adapter (Adapter_0), not
the shared storage adapter (Adapter_1).
NOTE
DO NOT define the shared storage arrays at this time. They will be defined later.
11. From the Navigator main menu install a utility partition on the local storage disk by choosing
Configuration Assistant and Installation Assistant, then Custom,
Microsoft, MS Windows NT 4.0 Enterprise Edition, and Nofor automated NOS
installation.
12. Choose Install/Update Utility Partition.
When finished, the system reboots and displays the Custom Configuration window.
13. Make an NT 4.0 Drivers floppy disk by choosing Create Driver Diskette(s),Execute,
and following the prompts. Label the floppy disk NT 4.0 Drivers.
Copy the NetRAID Driver for Clusters
Copy the “Mraidnt.sys” file from the NR Firmware & Driver floppy disk to the “\Netraid” directory on the
NT 4.0 Drivers floppy disk you created in step 13 above (page 18). You can do this either by booting the
server on which you are installing to DOS and copying the file, or by copying this file using another
computer:
This will overwrite the NetRAID single system driver already there with the NetRAID cluster driver.
NOTE
Do not copy the oemsetup.inf file on the NR Firmware & Driver floppy disk.
Install Windows NT
NOTE
Windows NT must be installed from floppy disks, not the CD, so that the mass storage
drivers will be loaded correctly. If you have not created a set of Windows NT boot
floppy disks, see Software in part “1 What’s Needed” for additional information.
1. Insert the boot floppy for Windows NT4.0 and exit Navigator to reboot the server.
2. When Setup prompts to detect mass storage devices, skip detection and manually specify the mass
storage drivers:
3. Load drivers using the NT 4.0 Drivers floppy disk you created in step 13 above (page 18).
•
•
•
Load the driver for the device you want to boot from. This will be the HP NetRAID Adapter Driver.
Load the IDE driver, since the CD drive is on the IDE bus.
Load any other mass storage drivers you need. If you are using the embedded SCSI channels, load
the Symbios driver at this time.
4. Continue the installation and select the following options when prompted:
•
•
Choose the unpartitioned space and install Windows NT.
Choose NTFS file system
HP NetServer Installation Guide
18
Download from Www.Somanuals.com. All Manuals Search And Download.
•
When prompted to search for a Network Adapter, load NIC drivers for both the intra-cluster and the
client LAN. Be sure to load the correct intra-cluster LAN driver version as specified in the
Configuration Guide for your cluster. If you are using two HP D5013A NICs, load the driver twice,
once for the intra-cluster NIC and once for the client NIC.
•
•
Make sure TCP/IP Protocolis selected.
Other protocols may be selected in addition, but TCP/IP is required.
If you are using two HP D5013A NICs, when prompted for TCP/IP Properties:
Make sure adapter [2] is highlighted and specify its IP address and subnet mask. This will be the
LAN adapter for the intra-cluster LAN.
Select adapter [1] and specify its IP address and subnet mask. This will be the LAN adapter for the
client LAN.
Set TCP/IP Properties for DNS, WINS Address, etc. at this time.
NOTE
The Client LAN IP addresses and Intra-cluster LAN IP addresses must be on different
subnets.
5. Once the NT installation is complete, the D5013A NIC drivers must be manually set to the correct LAN
speed. Log on and from the start menu select: Settings, Control Panel, Network, and
Adapters. For each D5013A adapter, select Propertiesthen Settingsand set the network
speed to the appropriate setting (either 10 Mbps or 100 Mbps) for your network. The intra-cluster LAN
should be set to 100 Mbps. Do not use the Auto setting.
LH 4
These procedures provide instructions for servers using NetRAID, AutoRAID Model 12H, and Model 30/FC
shared storage solutions.
Configure NetServer Hardware and BIOS
6. Make sure you power down System A and power up System B.
7. Insert the HP NetServer Navigator CD in the CD-ROM drive and restart the server.
8. During reboot enter the Setup Utility by pressing F2.
9. Select User Preferencesand then the LH4 Integrated NetRAIDsetting you want to use.
If you are using NetRAID for shared storage, disable the LH4 Integrated HP NetRAID.
It must be disabled otherwise it will conflict with the HP NetRAID adapter used for shared storage.
10. Exit the Setup Utility (F10, Save, and Exit).
The server reboots. If you have special NetServer local SCSI bus options enter the Symbios utility, by
pressing Ctrl+C at the Symbios boot banner during reboot and set the options you need; otherwise allow
the server to reboot. The server boots from the CD and displays the Navigator Main menu.
NOTE
If prompted that the HP NetServer Navigator BIOS is a newer version, choose
Continueand go to step 6; otherwise go to step 9.
11. To update the BIOS, choose Configuration Assistant and Installation Assistant,
then Custom, Microsoft, MS Windows NT 4.0 Enterprise Edition, and Nofor
automated NOS installation.
HP NetServer Installation Guide
19
Download from Www.Somanuals.com. All Manuals Search And Download.
12. Select Update, then Execute. Follow screen prompts to update the BIOS.
13. After the server reboots, return to the Navigator main menu by clicking the Back button twice on the
displayed window.
14. From the Navigator main menu, install a utility partition on the local storage disk by choosing
Configuration Assistant and Installation Assistant, Custom, Microsoft,
then either:
• MS Windows NT4.0 Enterprise Edition Cluster Server if using Navigator if
L.15.05 or later.
• MS Windows NT 4.0 Enterprise Edition, and Nofor automated NOS installation if
using Navigator L.15.04 or earlier.
15. Choose Install/Update Utility Partition.
When finished, the system reboots and displays the Custom Configuration window.
16. Make a NT4.0 Drivers floppy disk by choosing Create Driver Diskette(s),Execute,and
following the prompts. Label the floppy disk NT 4.0 Drivers.
17. Return to the Navigator main menu by clicking the Back button three times.
Install Windows NT
NOTE
Windows NT must be installed from floppy disks, not the CD, so that the mass storage
drivers will be loaded correctly. If you have not created a set of Windows NT boot
floppy disks, see Software in part “1 What’s Needed” in the installation guide supplement
for additional information.
18. Insert the boot floppy disk for Windows NT4.0 and exit Navigator to reboot the server.
19. When Windows NT Setup prompts to detect mass storage devices, skip detection and manually specify
the mass storage drivers:
•
•
The drivers are loaded from the NT 4.0 Drivers floppy disk you created from the Navigator CD.
First, load the driver for the device you want to boot from. For drives in the LH 4 internal bays this
will normally be the embedded SCSI Symbios driver.
•
•
Secondly, load the IDE driver, since the CD drive is on the IDE bus.
Finally, load any other mass storage drivers you need. If you are using NetRAID for shared storage
do not load the HP NetRAID driver at this time. It will be loaded later.
20. Continue the installation using floppy disks#2 and #3 and select the following options when prompted:
•
•
•
Choose the unpartitioned space and install Windows NT.
Choose NTFS file system
When prompted to search for a Network Adapter, load NIC drivers for both the intra-cluster and the
client LAN. Be sure to load the correct intra-cluster LAN driver version as specified in the
Configuration Guide for your cluster. If you are using two HP D5013A NICs, load the driver twice,
once for the intra-cluster NIC and once for the client NIC.
•
Make sure TCP/IP Protocolis selected.
Other protocols may be selected in addition, but TCP/IP is required.
HP NetServer Installation Guide
20
Download from Www.Somanuals.com. All Manuals Search And Download.
•
If you are using two HP D5013A NICs, when prompted for TCP/IP Properties:
Make sure adapter [2] is highlighted and specify its IP address and subnet mask. This will be the
LAN adapter for the intra-cluster LAN.
Select adapter [1] and specify its IP address and subnet mask. This will be the LAN adapter for the
client LAN.
Set TCP/IP Properties for DNS, WINS Address, etc. at this time.
NOTE
The Client LAN IP addresses and Intra-cluster LAN IP addresses must be on different
subnets.
21. Once the NT installation is complete, the D5013A NIC drivers must be manually set to the correct LAN
speed. Log on and from the start menu select: Settings, Control Panel, Network, and
Adapters. For each D5013A adapter, select Propertiesthen Settingsand set the network
speed to the appropriate setting (either 10 Mbps or 100 Mbps) for your network. The intra-cluster LAN
should be set to 100 Mbps. Do not use the Auto setting.
LPr
These procedures provide instructions for servers using NetRAID and AutoRAID shared storage solutions.
NOTE
If you are use NetRAID adapters for both shared and local storage go to the next
procedure, LPr (with NetRAID Local and Shared Storage) on page 25.
Configure NetServer Hardware and BIOS
1. Make sure you power down System A and power up System B.
2. Insert the HP NetServer Navigator CD in the CD-ROM drive and restart the server.
3. If you have special NetServer local SCSI bus options enter the Symbios utility by pressing Ctrl+C at the
Symbios boot banner during boot and set the options you need; otherwise allow the server to boot. The
server boots from the CD and displays the Navigator Main Menu.
NOTE
If prompted that the HP NetServer Navigator BIOS is a newer version, choose
Continueand go to step 4; otherwise go to step 6.
4. To update the BIOS, choose NetServer Utilities | More NetServer Utilities |
BIOS Update Utility. Select Executeand follow the screen prompts to update the BIOS.
5. After the server reboots, return to the Navigator main menu by clicking the Back button twice on the
displayed window.
6. From the Navigator main menu, install a utility partition on the local storage disk by choosing
Configuration Assistant and Installation Assistant, Custom, Microsoft,
then either:
• MS Windows NT4.0 Enterprise Edition Cluster Server if using Navigator if
L.15.05 or later.
• MS Windows NT 4.0 Enterprise Edition, and Nofor automated NOS installation if
using Navigator L.15.04 or earlier.
HP NetServer Installation Guide
21
Download from Www.Somanuals.com. All Manuals Search And Download.
7. Choose Install/Update Utility Partition and Execute.
When finished, the system reboots and displays the Custom Configuration window.
8. Make an NT 4.0 Drivers floppy disk by choosing Create Driver Diskette(s),Execute,
and following the prompts. Label the floppy disk NT 4.0 Drivers.
9. Press the Backbutton three times to return the Navigator Main Menu.
10. If you are using a NetRAID adapter for either shared or local storage, create a set of installation floppy
disks for NetRAID Assistant by choosing NetServer Utilities | Diskette Library.
Select NetRAID Assistant for WindowsNTand Windows95from the list and then the
Executebutton. Follow the instructions to create the NetRAID Assistant installation floppy disks.
Label the floppy disks HP NetRAID Assistant 1 and HP NetRAID Assistant 2.
Install Windows NT
NOTE
Windows NT must be installed from floppy disks, not the CD, so that the mass storage
drivers will be loaded correctly. If you have not created a set of Windows NT boot
floppy disks, see Software in part “1 What’s Needed” for additional information.
1. Remove the HP NetServer Navigator CD, insert the boot floppy for Windows NT4.0, and exit Navigator
to reboot the server.
2. When Setup prompts to detect mass storage devices, skip detection and manually specify the mass
storage drivers:
•
•
The drivers are loaded from the NT 4.0 Drivers floppy disk you created from the Navigator CD.
First, load the driver for the device you want to boot from. For drives in the LPr internal bays this
will normally be the embedded SCSI Symbios driver on the drivers disk. Select "SCSI Symbios
driver for the HP NetServer LPr."
•
•
Secondly, load the IDE driver, since the CD drive is on the IDE bus.
Finally, load any other mass storage drivers you need. If you are using NetRAID for shared storage
do not load the HP NetRAID driver at this time. It will be loaded later.
3. Continue the installation, inserting floppy disk #3 and select the following options when prompted:
•
•
•
Choose the unpartitioned space and install Windows NT.
Choose NTFS file system
When prompted to search for a Network Adapter, load NIC drivers for both the intra-cluster and the
client LAN. Be sure to load the correct intra-cluster LAN driver version as specified in the
Configuration Guide for your cluster. If you are using two HP D5013A NICs, load the driver twice,
once for the intra-cluster NIC and once for the client NIC.
•
•
Make sure TCP/IP Protocolis selected.
Other protocols may be selected in addition, but TCP/IP is required.
If you are using two HP D5013A NICs, when prompted for TCP/IP Properties:
Make sure adapter [2] is highlighted and specify its IP address and subnet mask. This will be the
LAN adapter for the intra-cluster LAN.
Select adapter [1] and specify its IP address and subnet mask. This will be the LAN adapter for the
client LAN.
Set TCP/IP Properties for DNS, WINS Address, etc. at this time.
HP NetServer Installation Guide
22
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTE
The Client LAN IP addresses and Intra-cluster LAN IP addresses must be on different
subnets.
4. Once the NT installation is complete, the D5013A NIC drivers must be manually set to the correct LAN
speed. Log on and from the start menu select: Settings, Control Panel, Network, and
Adapters. For each D5013A adapter, select Propertiesthen Settingsand set the network
speed to the appropriate setting (either 10 Mbps or 100 Mbps) for your network. The intra-cluster LAN
should be set to 100 Mbps. Do not use the Auto setting.
LPr (with NetRAID Local and Shared Storage)
A NetRAID adapter may only be used for either shared storage or local storage; one adapter may not be used for
both. To use NetRAID adapters for both shared and local storage, you must use two adapters.
Configure NetServer Hardware and BIOS
1. Make sure you power down System A and power up System B.
2. Insert the HP NetServer Navigator CD in the CD-ROM drive and restart the server.
3. If you have special NetServer local SCSI bus options enter the Symbios utility by pressing Ctrl+C at the
Symbios boot banner during boot and set the options you need; otherwise allow the server to boot. The
server boots from the CD and displays the Navigator Main Menu.
NOTE
If prompted that the HP NetServer Navigator BIOS is a newer version, choose
Continueand go to step 4; otherwise go to step 6.
4. To update the BIOS, choose NetServer Utilities | More NetServer Utilities |
BIOS Update Utility. Select Executeand follow the screen prompts to update the BIOS.
5. After the server reboots, return to the Navigator main menu by clicking the Back button twice on the
displayed window.
6. From the Navigator main menu, install a utility partition on the local storage disk by choosing
Configuration Assistant and Installation Assistant, Custom, Microsoft,
then either:
• MS Windows NT4.0 Enterprise Edition Cluster Server if using Navigator if
L.15.05 or later.
• MS Windows NT 4.0 Enterprise Edition, and Nofor automated NOS installation if
using Navigator L.15.04 or earlier.
7. Define the local storage RAID arrays. Select Configure Disk Arrayand use HP NetRAID
Assistant to define the arrays. Be sure to define the arrays for the local storage adapter (Adapter_0), not
the shared storage adapter (Adapter_1).
NOTE
DO NOT define the shared storage arrays at this time. They will be defined later.
8. Exit HP NetRAID Assistant. The server will reboot.
During the reboot, at the NetRAID banner press <Ctrl><M>to enter the NetRAID Express utility.
From the Management Menu, check that the BIOS is enabled. If it is not, enable it.
9. Exit the NetRAID Express utility and reboot. Navigator will return to the Custom Configuration screen.
Install a utility partition on the local storage disk by choosing Install/Update Utility
Partition.
After installing the utility partition, Navigator returns to the Custom Configuration screen.
HP NetServer Installation Guide
23
Download from Www.Somanuals.com. All Manuals Search And Download.
10. Make an NT 4.0 Drivers floppy disk by choosing Create Driver Diskette(s),Execute,
and following the prompts. Label the floppy disk NT 4.0 Drivers.
11. Press the Backbutton three times to return the Navigator Main Menu.
12. Create a set of installation floppy disks for NetRAID Assistant by choosing NetServer Utilities
| Diskette Library. Select NetRAID Assistant for WindowsNTand Windows95
from the list and then the Executebutton. Follow the instructions to create the NetRAID Assistant
installation floppy disks. Label the floppy disks HP NetRAID Assistant 1 and HP NetRAID Assistant 2.
Install Windows NT
NOTE
Windows NT must be installed from floppy disks, not the CD, so that the mass storage
drivers will be loaded correctly. If you have not created a set of Windows NT boot
floppy disks, see Software in part “1 What’s Needed” for additional information.
1. Remove the Navigator CD, insert the boot floppy for Windows NT4.0, and exit Navigator to reboot the
server.
2. When Setup prompts to detect mass storage devices, skip detection and manually specify the mass
storage drivers:
3. Load drivers using the NetRAID-3Si Cluster Firmware and Driver floppy disk you created in part 1
“What’s Needed” and the NT 4.0 Drivers floppy disk you created in step 10 above of this procedure.
•
Load the driver for the device you want to boot from. This will be the HP NetRAID Adapter Driver.
If you are using a NetRAID-3Si Adapter for shared storage, load this driver from the NetRAID-3Si
Cluster Firmware and Driver floppy disk. Be sure to use the driver version specified for shared
storage in the Configuration Guide, since this driver is used for both the NetRAID local storage
adapter and the NetRAID-3Si shared storage adapter.
•
•
Load the IDE driver from the NT 4.0 Drivers floppy disk, since the CD drive is on the IDE bus.
Load any other mass storage drivers you need. If you are using the embedded SCSI channel, load
the Symbios driver from the NT 4.0 Drivers floppy disk at this time.
4. Continue the installation and select the following options when prompted:
•
•
•
Choose the unpartitioned space and install Windows NT.
Choose NTFS file system
When prompted to search for a Network Adapter, load NIC drivers for both the intra-cluster and the
client LAN. Be sure to load the correct intra-cluster LAN driver version as specified in the
Configuration Guide for your cluster. If you are using two HP D5013A NICs, load the driver twice,
once for the intra-cluster NIC and once for the client NIC.
•
•
Make sure TCP/IP Protocolis selected.
Other protocols may be selected in addition, but TCP/IP is required.
If you are using two HP D5013A NICs, when prompted for TCP/IP Properties:
Make sure adapter [2] is highlighted and specify its IP address and subnet mask. This will be the
LAN adapter for the intra-cluster LAN.
Select adapter [1] and specify its IP address and subnet mask. This will be the LAN adapter for the
client LAN.
Set TCP/IP Properties for DNS, WINS Address, etc. at this time.
HP NetServer Installation Guide
24
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTE
The Client LAN IP addresses and Intra-cluster LAN IP addresses must be on different
subnets.
5. Once the NT installation is complete, the D5013A NIC drivers must be manually set to the correct LAN
speed. Log on and from the start menu select: Settings, Control Panel, Network, and
Adapters. For each D5013A adapter, select Propertiesthen Settingsand set the network
speed to the appropriate setting (either 10 Mbps or 100 Mbps) for your network. The intra-cluster LAN
should be set to 100 Mbps. Do not use the Auto setting.
LX/LXr Pro
Configure NetServer Hardware and BIOS
1. Make sure you power down System A and power up System B.
2. Insert the HP NetServer Navigator CD in the CD-ROM drive of System B and restart the server.
The server boots from the CD and displays the Navigator Main menu.
NOTE
If prompted that the HP NetServer Navigator BIOS is a newer version, choose
Continueand go to step 3; otherwise go to step 6.
3. To update the BIOS, choose Configuration Assistant, then Custom, Microsoft, MS
Windows NT 4.0 Enterprise Edition, and Nofor automated NOS installation.
4. Select Update, then Execute. Follow screen prompts to update the BIOS.
5. After the server reboots return to the Navigator main menu by clicking the Back button twice on the
displayed window.
6. From the Navigator Main menu, choose NetServer Utilities, then EISA Configuration
Utility.
7. At the Utility window select Step 3 - View or Edit Detailsand:
•
•
Make sure MP Spec Versionis set to V1.4.
Disable the on-board IDE Hard Disk Controller by scrolling to On-board IDE Hard Disk
Controller, pressing Enter, and choosing Disable.
The embedded IDE controller is not used on the HP NetServer LX and LXr Pro.
8. Save and exit the EISA Configuration Utility.
The utility saves the configuration data, restarts the server, and reloads the HP NetServer Navigator CD.
9. Install a utility partition on the local storage disk by choosing Configuration Assistant, then
Custom, Microsoft, MS Windows NT 4.0 Enterprise Edition, and Nofor automated
NOS installation.
10. Choose Install/Update Utility Partition.
When finished, the system reboots and displays the Custom Configuration window.
Install Windows NT
1. Remove the HP NetServer Navigator CD, insert the first CD of the Microsoft Windows NT Server,
Enterprise Edition, and exit Navigator to reboot the server.
2. Select the following options when prompted:
•
•
Choose the unpartitioned space and install Windows NT.
Choose NTFS file system
HP NetServer Installation Guide
25
Download from Www.Somanuals.com. All Manuals Search And Download.
•
•
When prompted to search for a Network Adapter, load NIC drivers for both the intra-cluster and the
client LAN. Be sure to load the correct intra-cluster LAN driver version as specified in the
Configuration Guide for your cluster. If you are using two HP D5013A NICs, load the driver twice,
once for the intra-cluster NIC and once for the client NIC.
Make sure TCP/IP Protocolis selected.
Other protocols may be selected in addition, but TCP/IP is required.
•
Set TCP/IP Properties for DNS, WINS Address, etc. at this time.
NOTE
The Client LAN IP addresses and Intra-cluster LAN IP addresses must be on different
subnets.
LXr 8000
These procedures provide instructions for servers using NetRAID, AutoRAID Model 12H, and Model 30/FC
shared storage solutions
Configure NetServer Hardware and BIOS
1. Make sure you power down System A and power up System B.
2. Insert the HP NetServer Navigator CD in the CD-ROM drive and restart the server.
NOTE
If prompted that the HP NetServer Navigator BIOS is a newer version, choose
Continueand go to step 3; otherwise go to step 6.
3. To update the BIOS, choose Configuration Assistant, then Custom, Microsoft, MS
Windows NT 4.0 Enterprise Edition, and Nofor automated NOS installation.
4. Select Update, then Execute. Follow screen prompts to update the BIOS.
5. After the server reboots, return to the Navigator main menu by clicking the Back button twice on the
displayed window.
6. From the Navigator main menu, install a utility partition on the local storage disk by choosing
Configuration Assistant and Installation Assistant, Custom, Microsoft,
then either:
• MS Windows NT4.0 Enterprise Edition Cluster Server if using Navigator if
L.15.05 or later.
• MS Windows NT 4.0 Enterprise Edition, and Nofor automated NOS installation if
using Navigator L.15.04 or earlier.
7. Choose Install/Update Utility Partition.
When finished, the system reboots and displays the Custom Configuration window.
8. Make an NT 4.0 Drivers floppy disk by choosing Create Driver Diskette(s),Execute, and
following the prompts. Label the floppy disk NT 4.0 Drivers.
HP NetServer Installation Guide
26
Download from Www.Somanuals.com. All Manuals Search And Download.
Install Windows NT
NOTE
Windows NT must be installed from floppy disks, not the CD, so that the mass storage
drivers will be loaded correctly. If you have not created a set of Windows NT boot
floppy disks, see Software in part “1 What’s Needed” for additional information.
1. Insert the boot floppy disk for Windows NT4.0 and exit Diagnostic Assistant to reboot the server.
2. When Setup prompts to detect mass storage devices, skip detection and manually specify the mass
storage drivers:
•
•
The drivers are loaded from the NT 4.0 Drivers floppy disk you created from the Navigator CD.
First, load the driver for the device you want to boot from. For drives in the LXr 8000 internal bays
this will normally be the embedded SCSI Symbios driver.
•
•
Secondly, load the IDE driver, since the CD drive is on the IDE bus.
Finally, load any other mass storage drivers you need. If you are using NetRAID for shared storage
do not load the HP NetRAID driver at this time. It will be loaded later.
3. Continue the installation and select the following options when prompted:
•
•
•
Choose the unpartitioned space and install Windows NT.
Choose NTFS file system
When prompted to search for a Network Adapter, load NIC drivers for both the intra-cluster and the
client LAN. Be sure to load the correct intra-cluster LAN driver version as specified in the
Configuration Guide for your cluster. If you are using two HP D5013A NICs, load the driver twice,
once for the intra-cluster NIC and once for the client NIC.
•
•
Make sure TCP/IP Protocolis selected.
Other protocols may be selected in addition, but TCP/IP is required.
If you are using two HP D5013A NICs, when prompted for TCP/IP Properties:
Make sure adapter [1] is highlighted and specify its IP address and subnet mask. This will be the
LAN adapter for the intra-cluster LAN.
Select adapter [2] and specify its IP address and subnet mask. This will be the LAN adapter for the
client LAN.
Set TCP/IP Properties for DNS, WINS Address, etc. at this time.
NOTE
The Client LAN IP addresses and Intra-cluster LAN IP addresses must be on different
subnets.
4. Once the NT installation is complete, the D5013A NIC drivers must be manually set to the correct LAN
speed. Log on and from the start menu select: Settings, Control Panel, Network, and
Adapters. For each D5013A adapter, select Propertiesthen Settingsand set the network
speed to the appropriate setting (either 10 Mbps or 100 Mbps) for your network. The intra-cluster LAN
should be set to 100 Mbps. Do not use the Auto setting.
HP NetServer Installation Guide
27
Download from Www.Somanuals.com. All Manuals Search And Download.
LXr 8000 (with Fibre Channel)
These procedures provide instructions for servers using Fibre Channel shared storage solutions (HP Rack
Storage/12FC.
Configure NetServer Hardware and BIOS
1. System A and System B can both be powered on.
2. Insert the HP NetServer Navigator CD in the CD-ROM drive and restart the server.
3. During reboot enter the Setup Utility by pressing F2.
4. Select User Preferencesand then the LH4 Integrated NetRAIDsetting you want to use.
5. Exit the Setup Utility (F10, Save, and Exit).
The server reboots. If you have special NetServer local SCSI bus options enter the Symbios utility, by
pressing Ctrl+C at the Symbios boot banner during reboot and set the options you need; otherwise allow
the server to reboot. The server boots from the CD and displays the Navigator Main menu.
NOTE
If prompted that the HP NetServer Navigator BIOS is a newer version, choose
Continueand go to step 6; otherwise go to step 9.
6. To update the BIOS, choose Configuration Assistant and Installation Assistant,
then Custom, Microsoft, MS Windows NT 4.0 Enterprise Edition, and Nofor
automated NOS installation.
7. Select Update, then Execute. Follow screen prompts to update the BIOS.
8. After the server reboots, return to the Navigator main menu by clicking the Back button twice on the
displayed window.
9. From the Navigator main menu, install a utility partition on the local storage disk by choosing
Configuration Assistant and Installation Assistant, Custom, Microsoft,
then MS Windows NT4.0 Enterprise Edition Cluster Server.
10. Choose Install/Update Utility Partition.
When finished, the system reboots and displays the Custom Configuration window.
11. Make a NT4.0 Drivers floppy disk by choosing Create Driver Diskette(s),Execute,and
following the prompts. Label the floppy disk NT 4.0 Drivers.
12. Return to the Navigator main menu by clicking the Back button three times.
Install Windows NT
NOTE
Windows NT must be installed from floppy disks, not the CD, so that the mass storage
drivers will be loaded correctly. If you have not created a set of Windows NT boot
floppy disks, see Software in part “1 What’s Needed” of the installation guide supplement
for additional information.
1. Insert the boot floppy disk for Windows NT4.0 and exit Navigator to reboot the server.
2. When Windows NT Setup prompts to detect mass storage devices, skip detection and manually specify
the mass storage drivers:
•
The drivers are loaded from the NT 4.0 Drivers floppy disk you created from the Navigator CD.
HP NetServer Installation Guide
28
Download from Www.Somanuals.com. All Manuals Search And Download.
•
First, load the driver for the device you want to boot from. For drives in the LH 4 internal bays this
will normally be the embedded SCSI Symbios driver or embedded NetRAID.
•
•
Secondly, load the IDE driver, since the CD drive is on the IDE bus.
Finally, load any other mass storage drivers you need. If you are using the Fibre Channel HBA for
shared storage do not load the HP Fibre Channel driver at this time. It will be loaded later.
3. Continue the installation using floppy disks#2 and #3 and select the following options when prompted:
•
•
•
Choose the unpartitioned space and install Windows NT.
Choose NTFS file system
When prompted to search for a Network Adapter, load NIC drivers for both the intra-cluster and the
client LAN. Be sure to load the correct intra-cluster LAN driver version as specified in the
Configuration Guide for your cluster. If you are using two HP D5013A NICs, load the driver twice,
once for the intra-cluster NIC and once for the client NIC.
•
•
Make sure TCP/IP Protocolis selected.
Other protocols may be selected in addition, but TCP/IP is required.
If you are using two HP D5013A NICs, when prompted for TCP/IP Properties:
Make sure adapter [2] is highlighted and specify its IP address and subnet mask. This will be the
LAN adapter for the intra-cluster LAN.
Select adapter [1] and specify its IP address and subnet mask. This will be the LAN adapter for the
client LAN.
Set TCP/IP Properties for DNS, WINS Address, etc. at this time.
NOTE
The Client LAN IP addresses and Intra-cluster LAN IP addresses must be on different
subnets.
4. Once the NT installation is complete, the D5013A NIC drivers must be manually set to the correct LAN
speed. Log on and from the start menu select: Settings, Control Panel, Network, and
Adapters. For each D5013A adapter, select Propertiesthen Settingsand set the network
speed to the appropriate setting (either 10 Mbps or 100 Mbps) for your network. The intra-cluster LAN
should be set to 100 Mbps. Do not use the Auto setting.
Part "6 Shared Storage Software Setup" in the Shared Storage Supplement and start with
Install Fibre Channel HBA Driver.
Install Service Pack for All HP NetServers
Refer to the Configuration Guide for your cluster configuration and install the applicable Microsoft Service
Pack (SP3 or SP4). Do not install the Hot Fix associated with Service Pack 3 at this time.
NOTE
NOTE
Do not install the Microsoft Cluster Server Software (MSCS) at this time.
After completing these procedures, power down System B and power up System A.
Repeat all of the procedures in this part for System A.
HP NetServer Installation Guide
29
Download from Www.Somanuals.com. All Manuals Search And Download.
For Fibre Channel solutions using the Rack Storage/12FC simply reboot System B and
repeat the procedures on Systems A. Both systems can be powered up.
HP NetServer Installation Guide
30
Download from Www.Somanuals.com. All Manuals Search And Download.
6 Shared Storage Software Setup
Use these procedures to install host bus adapter (interface) software, create the arrays and array file systems.
Shared Storage Setup
Part "6 Shared Storage Software Setup" in the Shared Storage Supplement. For Fibre
Channel solutions go to Configure the Storage Devices using FCArray Assistant in the
supplement
Create the Array File Systems
Use the instructions below and Windows NT Disk Administrator to partition, assign drive letters, and format
the shared logical drives.
Reboot System A
Reboot System A so that Windows NT can recognize the logical drives created when you setup the shared
storage. The system boots and loads Windows NT on System A.
CAUTION
You must reboot System A to get accurate information about your shared disks before
running Disk Administrator.
Run Windows NT Disk Administrator
From the Start menu, choose Programs, Administrative Tools, and then Disk
Administrator. Disk Administrator loads and scans the disks, and displays a list of the logical disks you
identified. An example display follows:
NOTE
Disk Administrator lists disks in order, beginning with local (non-shared) disks followed
by the shared disk arrays.
HP NetServer Installation Guide
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Disk Administrator, Scanned Logical Disks
Create Full Disk Partitions for each Array
1. Click the disk box to select the shared array to be partitioned.
Disk Administrator highlights the selected disk.
2. From Disk Administrator’s Partitionmenu, choose Create.
A dialog appears indicating the maximum size of a single partition.
NOTE
Don’t be misled by the displayed disk capacity for your arrays. When Disk Administrator
calculates disk capacity, it disregards redundancy storage used by the selected RAID
level. The displayed and usable storage capacity for the array is, therefore, less than the
total capacity of all drives in the array. For example, the displayed and usable array
capacity for a RAID 5 array would be C(N-1), where N is the number of drives and C is
the capacity of one drive. Likewise, for RAID 1 the capacity would be one-half the
capacity of the two drives.
3. Click OKto include the full disk in the partition (the default).
In the following example, Disk 1 has been partitioned and Disk Administrator assigned a temporary
drive letter to the disk array.
HP NetServer Installation Guide
32
Download from Www.Somanuals.com. All Manuals Search And Download.
Disk Administrator, Partitioned Disk Array
NOTE
Do not partition a disk into separate drives. Microsoft Cluster Server Software will only
manage one partition per disk.
4. Repeat steps 1 through 3 to create a partition for each disk array to be shared by the cluster.
5. From Disk Administrator’s Partitionmenu, choose Commit Changes Now, then choose Yesto
save changes and OKwhen prompted.
NOTE
In the following example, Disk 2 has been partitioned and Disk Administrator assigned
the next sequential letter to the disk array.
HP NetServer Installation Guide
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Disk Administrator, All Disk Arrays Partitioned and Committed
Assign Drive Letters
Disk Administrator has assigned sequential and temporary drive letters to the disk arrays you partitioned.
You must assign a permanent (static) drive letter to each drive you want to make available to both Systems A
and B.
NOTE
When partitioning logical drives with Windows NT the logical drive letters are
sequentially assigned in a predefined sequence. These drive letters are temporary
assignments that can change according to the drives installed in your system. For
clustered systems it is critical that the drive letters for the shared storage drives be fixed.
Therefore, make sure that you assign permanent drive letters to the shared logical drives.
1. Select one of the disks you just partitioned.
Disk Administrator highlights the selected disk.
2. From the Disk Administrator’s Toolsmenu, choose Assign Drive Letter.
Disk Administrator displays the Assign Drive Letterdialog.
3. In the dialog, select a drive letter, and click OK.
To avoid confusion later, HP recommends that you choose sequential drive letters. The example in this
guide uses drive letters X and Y.
HP NetServer Installation Guide
34
Download from Www.Somanuals.com. All Manuals Search And Download.
Disk Administrator, Assigning Drive Letters
4. Repeat steps 1 through 3 to assign a drive letter for each array to be shared in the cluster.
Format Logical Drives
1. Click a disk box to select one of the arrays that you just partitioned and assigned a drive letter.
Disk Administrator highlights the selected disk.
2. From the Disk Administrator’s Toolsmenu, choose Format.
A dialog appears with a list of formatting options.
Disk Administrator, Formatting and Assigning Volume labels
3. In the Formatdialog make sure that File Systemis set for NTFS.
4. In the Volume Labelfield type a label (name) for the drive.
Choose a descriptive label such as "Shared Drive X.".
HP NetServer Installation Guide
35
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Select Quick Formatin the Format Optionsfield, and then Startto begin formatting the
logical drive.
NOTE
No action is necessary for the Capacityand Allocation Unit Sizefields.
6. Repeat steps 1 through 5 to format each drive to be shared in the cluster.
The following example depicts both drives formatted with permanent drive letters assigned.
Disk Administrator, Formatting and Assigning Volume labels
7. Exit Disk Administrator.
HP NetServer Installation Guide
36
Download from Www.Somanuals.com. All Manuals Search And Download.
7 Microsoft Cluster Server Software Setup
During installation of Microsoft Cluster Server Software (MSCS) at System A, you will create a Microsoft
Cluster Server. Initially, it is a cluster with only one server (System A). Later, you will join System B to the
cluster and thus create a standard two-server (node) cluster. If you need more information about the
installation process outlined here, see the Microsoft Cluster Server Administrators Guide.
Install MSCS on System A
MSCS installation includes slightly different software setups for System A and System B. Since you just
finished configuring arrays on System A, continue Microsoft Cluster Server Setup where you left off with
Disk Administrator.
To install MSCS at System A:
1. Insert the Component CD of Microsoft Windows NT Server, Enterprise Edition in the CD-ROM drive of
System B.
2. Run the Microsoft Cluster Server setup program.
Setup.exe is located in the following folder on the Component CD: \mscs\cluster\i386
3. Choose Form a new clusterand click Next.
Setup prompts you to identify the cluster by name.
4. Type a name for the cluster. Make note of the name you type. You will need to provide the identical
name during Microsoft Cluster Server software setup of System A. Click Next.
Microsoft Cluster Administrator, Assigning a Cluster Name
HP NetServer Installation Guide
37
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Setup prompts you for the location to store cluster files. Either accept the default or type a new location
and click Next.
6. Setup prompts you for the cluster domain account. Provide a user name and password for an appropriate
Microsoft Domain account for the cluster. Click Next.
NOTE
If you are unsure of the correct MS Domain account, consult the Windows NT
documentation supplied with your system.
7. Setup presents a two-column list of Available unsharedand Shared cluster disks. Use
the Addand Removebuttons to place the disks in the desired columns. Click Next.
Keep in mind that disks listed in the left column are reserved for the exclusive use of System B while
disks listed in the right column are shared by both systems. Normally you would share all disks listed.
Microsoft Cluster Server Setup, Assigning Shared Disks to the Cluster
8. Setup prompts you to select a disk (quorum disk) on which to store permanent cluster files. Cluster
Administrator uses the disk you select to store synchronizing information about Systems A and B. The
disk must always be available to the cluster. Select the disk that you will commit to keeping online then
click Next.
9. Configure your LAN adapters.
Setup scans the System’s LAN adapters so they can be configured for cluster use and presents a dialog
for each LAN adapter installed in your HP NetServer. Setup uses the IP address you specified during
NT installation. Type a Network Namefor the LAN Adapter, and check Enable for cluster
use.
HP recommends that you identify the LAN adapter according to use (for example, intra-cluster LAN).
When you enable cluster use setup gives you three options:
• Use for all communications
Choose this option if you are configuring a client LAN adapter, and System A and B reside on
the same IP subnet.
HP NetServer Installation Guide
38
Download from Www.Somanuals.com. All Manuals Search And Download.
• Use only for internal cluster communications
Choose this option if you are configuring an intra-cluster LAN adapter.
• Use only for client access
Choose this option if you are configuring a client LAN adapter and System A and B reside on
different IP subnets.
NOTE
In this example, the intra-cluster LAN is shown first with the Adapter Nameand IP
Address already filled in. However, your configuration may display the Client LAN
first.
Microsoft Cluster Server Setup, Assigning a Network Name to the intra-cluster LAN
10. Repeat the previous step for each LAN adapter. After you have configured all LAN adapters, click
Next.
11. Setup lists your LAN adapters and asks you to prioritize them for internal communications between
nodes. Move the Intra-cluster LAN to the top of the list so it has the highest priority. See the example
dialog below.
HP NetServer Installation Guide
39
Download from Www.Somanuals.com. All Manuals Search And Download.
Microsoft Cluster Server Setup, Setting the LAN Priority
12. Follow the on-screen instructions to order the adapters so that the intra-cluster LAN adapter is identified
first (at the top of the list). After you have ordered the adapters click Next.
NOTE
If you previously defined the client IP addresses of Systems A and B as residing on
different subnets, the client LAN will be unable to assume responsibility for intra-cluster
communication.
13. Setup prompts you for the Cluster IP address. Type the proper IP address and subnet mask for the
CLUSTER, then click Next.
NOTE
The previous step requires a unique IP address for the cluster. Do not use either of the IP
addresses assigned to System A or System B.
14. Click Finishto complete installation of the Microsoft Cluster Server software.
Setup activates your configuration specifications and starts the cluster service.
15. Microsoft Cluster Server is now fully installed on System A. Reboot System A.
16. To finish installation of the Microsoft Cluster Server, leave System A running, go to the next procedure
and install MSCS on System B.
HP NetServer Installation Guide
40
Download from Www.Somanuals.com. All Manuals Search And Download.
Install MSCS on System B
While you have been configuring System A, System B has been idling at the Restart dialog.
1. Click Restartto reboot System B to Windows NT.
2. Insert the Component CD of Microsoft Windows NT Server (Enterprise Edition) in the CD-ROM drive
of System B.
3. Run the Microsoft Cluster Server setup program.
Setup.exe is located in the following folder on the Component CD: \mscs\cluster\i386.
4. Setup examines your system and displays a dialog that lists a number of install options including Join
an existing cluster.
5. Choose Join an existing clusterand click Next.
6. Identify the cluster using the same name you used when you formed the cluster at System B.
Setup validates your entry by prompting you for the cluster domain account password.
7. Type the password.
Setup prompts you to complete the installation upon entry of a valid password.
8. Click Finish.
You have now installed and configured all necessary software and hardware components to create a
Microsoft Cluster Server.
9. Reboot System B.
Install Service Pack or Hot Fix
After installing MSCS software your must either reinstall SP4 or if you installed SP 3, install the Hot Fix at
this time.
Install Hot Fix
Install the Hot Fix (clusfixi.exe):
1. If you have not already downloaded clusfixi.exe, see "Software" in part "1 What’s Needed."
2. Install the Microsoft hotfix clusfixi.exe on System A and System B.
NOTE
When downloading the file, refer to the Microsoft readme file for instructions on
installing the hotfix.
HP NetServer Installation Guide
41
Download from Www.Somanuals.com. All Manuals Search And Download.
8 Cluster Testing
There are two programs for testing the installed cluster. These programs are the Hardware Verification and
Labeling Utility and the Cluster Installation Test.
Hardware Verification and Labeling Utility
The Hardware Verification and Labeling Utility scans the system and checks system integrity before you
perform system configuration. It helps you simplify the assembly process that must be performed while
trying to setup a new product.
With this utility you can:
•
•
•
•
Create an asset inventory list
Check cabling connections
Label installed hardware
Health check hardware components
Obtain the Utility
The Hardware Verification and Labeling Utility is included on the HP NetServer Navigator CD-ROM. You
can run the test directly from the CD, or you can create a bootable floppy disk from HP NetServer
Navigator’s disk library. The floppy disk is bootable to ensure that it is independent of the customer’s network
operating system. However, it does not include COMMAND.COM, so it is not usable as a DOS disk.
Run the Utility
CAUTION
The Hardware and Verification Utility is designed to run on a single HP NetServer and
not a cluster. Therefore, to prevent corrupting the shared storage in your cluster, power
down the cluster node (HP NetServer) not being tested when running this test.
If the system is booted from the HP NetServer Navigator CD-ROM you will find that the utility does not
appear as a direct menu choice. However, when the Configuration Assistant is run, you will be given the
option of first running the Hardware Verification and Labeling Utility. This offer is only made the first time
Configuration Assistant is selected after a reboot.
The Hardware Verification and Labeling Utility is supplied with a README.TXT file. This file contains
detailed information on the utility and instructions for setting up and running the utility.
Cluster Installation Test
The HP Cluster Installation Test (CIT) should be performed on your installed cluster before placing it online.
The CIT performs an operational failover test of the cluster to verify that if a node fails the operating node
takes over all functions..
Obtain CIT
If you do not have CIT, see part "1 What’s Needed" for instructions to download this program.
Run CIT
Follow the instructions in the CIT program. If additional information is needed refer to CIT on-line help.
CIT help is context sensitive and has been expanded to provide detailed instructions for each step of the
program.
HP NetServer Installation Guide
42
Download from Www.Somanuals.com. All Manuals Search And Download.
HP A3661B Model 30/FC
High Availability Disk Array
Supplement
to
HP NetServer
Microsoft Cluster Installation Guide
July 1, 1998
Download from Www.Somanuals.com. All Manuals Search And Download.
Notice
The information in this document is subject to change without notice.
Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not limited to, the
implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for errors
contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of
this material.
This document contains proprietary information that is protected by copyright. No part of this document may be
photocopied, reproduced, or translated into another language without the prior written consent of Hewlett-Packard.
The information contained in this document is subject to change without notice.
Warranty
If you have any questions about the warranty for this product, contact your dealer.
Safety Considerations
The product and related documentation must be reviewed for familiarization with safety markings and instructions
before installation and operation.
Safety Symbols
WARNING
CAUTION
NOTE
A WARNING denotes a hazard that can cause personal injury.
A CAUTION denotes a hazard that can damage equipment or result in lost data.
A NOTE contains information that is useful in accomplishing a task.
Do not proceed beyond a WARNING or CAUTION notice until you understand the hazardous conditions and have
taken appropriate steps.
Grounding
The computer in which this product is installed is a safety class I product and has a protective earthing terminal. There
must be an uninterruptible safety earth ground from the main power source to the product’s input wiring terminals, power
cord, or supplied power cord set. Whenever it is likely that the protection has been impaired, disconnect the power cord
until the ground has been restored.
Servicing
Any servicing, adjustment, maintenance, or repair must be performed only by authorized service-trained personnel.
Trademark Notice
The use of trademarks or other designations is for reference purposes only. The following trademarks are used in this
manual:
®
Microsoft is a U.S. registered trademark of Microsoft Corporation.
WindowsTM and Windows NTTM are trademarks of Microsoft Corporation.
®
ArrayGUIdeTM is a trademark and CLARiiON is a U.S. registered trademark of Data General Corporation.
Enterprise NetServer Division
5301 Stevens Creek Boulevard
P.O. Box 58059
Santa Clara, CA 95052-8059, USA
© Copyright Hewlett-Packard Company 1998. All rights reserved.
2
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
OVERVIEW ..............................................................................................................................................................................4
INTRODUCTION........................................................................................................................................................................4
OPERATING SYSTEM................................................................................................................................................................4
1 – WHAT’S NEEDED? ...........................................................................................................................................................5
FIBRE CHANNEL IDS................................................................................................................................................................5
HARDWARE .............................................................................................................................................................................5
SOFTWARE...............................................................................................................................................................................5
TOOLS .....................................................................................................................................................................................5
NEED MORE HELP? .................................................................................................................................................................5
2 – HP NETSERVER HARDWARE SETUP .........................................................................................................................6
INSTALL THE FC I/O ADAPTER................................................................................................................................................6
3 – SHARED STORAGE HARDWARE SETUP ...................................................................................................................8
INSTALL THE HP FC-AL HUB .................................................................................................................................................8
INSTALL THE HP MODEL 30/FC HIGH AVAILABILITY DISK ARRAY .....................................................................................14
4 – CLUSTER CABLING AND SETUP ...............................................................................................................................26
5 – HP NETSERVER SOFTWARE SETUP.........................................................................................................................34
6 – SHARED STORAGE SOFTWARE SETUP...................................................................................................................35
INSTALL THE FIBRE CHANNEL DRIVER ON WINDOWS NT.....................................................................................................35
POWER UP THE HP MODEL 30/FC HIGH AVAILABILITY DISK ARRAY..................................................................................36
INSTALL THE HP MODEL 30/FC HIGH AVAILABILITY DISK ARRAY SOFTWARE ...................................................................38
SET THE HP MODEL 30/FC HIGH AVAILABILITY DISK ARRAY OPERATING MODE...............................................................39
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Overview
Introduction
An HP NetServer cluster provides a reliable, cabinet-mounted, increased-availability solution for critical applications.
The basic cluster consists of two HP NetServer systems coupled to an HP Fibre Channel Arbitrated Loop (FC-AL) hub
connected to an HP A3661B Model 30/FC High Availability Disk Array.
The HP Model 30/FC High Availability Disk Array is a high capacity mass storage device that can reside in the same
cabinet (also called a rack) as the HP NetServer and an HP FC-AL hub. It uses Fibre Channel technology to ensure fast,
reliable access to data.
Both HP NetServers use the HP Model 30/FC High Availability Disk Array as a shared external storage device, using a
TACHYON Fibre Channel Adapter Card that comes in the HP45246A Fibre Channel Adpater Kit for NT. A FC I/O
adapter card is located in each HP NetServer. Both HP NetServers run Microsoft Windows NTTM Server Enterprise
Edition, which includes Microsoft Cluster Server software.
Two HP FC-AL hubs, connected to each other in a cascading arrangement, can be used in a cluster. Also, additional disk
arrays can be used for shared external storage.
This guide is a reference to be used during unpacking, setup and installation of the FC I/O adapter, HP Model 30/FC
High Availability Disk Array, and HP FC-AL hub as components of your HP NetServer Microsoft Cluster configuration.
The HP Model 30/FC High Availability Disk Array is not customer installable. It must be unpacked and installed only
by authorized Hewlett-Packard service representatives. This guide is for the HP service representative who installs the
shared external storage units in an HP NetServer Microsoft Cluster.
NOTE
This document is incomplete without the HP NetServer Microsoft Cluster Installation Guide.
When prompted by this supplement, turn to the installation guide to get the necessary instructions.
Operating System
The HP Model 30/FC High Availability Disk Array is supported in clustered environments on HP NetServer LXr Pro8
Series systems running the Microsoft Windows NT 4.0 Service Pack 3 or later operating system. It is not supported as a
boot device on HP NetServers.
The required Fibre Channel driver for Windows NT is supplied on a diskette that comes with the FC I/O adapter.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
1 – What’s Needed?
Fibre Channel IDs
During HP Model 30/FC High Availability Disk Array installation, be prepared to supply one Fibre Channel ID for each
FC-AL connection between an HP FC-AL hub and an SP on an HP Model 30/FC High Availability Disk Array.
See part 3, step 5, table 2 of this guide for a list of Fibre Channel IDs.
Hardware
Compare the hardware you have with ordering documentation, such as the parts lists created by Order and Rack
Assistants. In general, the components for shared external storage components consist of two TACHYON Fibre Channel
Adapter Cards, each of which comes in a HP 45246A Fibre Channel Adapter Kit for NT, an HP A3724A short-wave or
HP A4839A long-wave FC-AL hub, an HP A3661B Model 30/FC High Availability Disk Array, and the Fibre Channel
optic cables used to interconnect these components.
Software
The following driver and diagnostics must be installed from the diskette that comes with the FC I/O adapter:
ì
ì
FC Driver, version 2.07 or later
Diagnostic, version 2.07 or later
The following host-resident utilities need to be installed from the CD-ROM that comes with the disk array as part of the
A5254A Fibre Channel Mass Storage media kit:
ì
ArrayGUIdeTM, version 1.7.0
Tools
Standard installation tools plus:
ì
ì
Torx™ T-25 driver, supplied in the Rack Installation Toolkit
Portable Field Service Grounding Kit (3M part number 8505, or the equivalent).
Need More Help?
The following reference materials may be useful when installing the FC I/O adapter, HP FC-AL hub and HP Model
30/FC High Availability Disk Array:
ì
Hewlett-Packard TACHYON Fibre Channel Adapter Card Installation Guide (HHBA-5000A) (part number
5090-4722).
ì
ì
ì
Hewlett-Packard Fibre Channel Arbitrated Loop Hub Service and User Manual (part number A3724-90006).
Hewlett-Packard Model 30/FC High Availability Disk Array Service Manual (part number A3232-90002).
Hewlett-Packard Model 30/FC High Availability Disk Array User’s Guide and Service Manual Addendum for
Microsoft Windows NT 4.0 (part number A3661-90019).
The manuals are enclosed with the hardware components.
To part 1 of the HP NetServer Installation Guide.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
2 – HP NetServer Hardware Setup
Install the FC I/O Adapter
1. Install the FC I/O Adapter in the PCI Slot
Install the FC I/O adapter in an appropriate PCI slot as specified in the Configuration Guide for the HP NetServer.
Installation steps are shown for both vertical and horizontal installations. Install a FC I/O adapter in each HP NetServer
in the cluster.
a. Make sure the HP NetServer is powered down.
b. Remove the chassis cover.
c. Locate the correct PCI expansion slot in the system.
d. Remove the expansion slot cover. Save the slot cover screw.
e. Insert the FC I/O adapter into the slot. Push the adapter into the slot until it clicks into place (see figure 1).
Vertical
Installation
Horizontal
Installation
Figure 1. Installing the FC I/O adapter
f. Replace the slot cover screw.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Install the GBIC
a. Locate the short-wave GBIC (Gigabit Interface Converter) included in the FC I/O adapter kit.
b. Install the GBIC into the receptacle on the FC I/O adapter (see figure 2).
NOTE
The GBIC can only be installed one way, because the GBIC and guide rails inside the FC I/O
adapter receptacle are keyed.
Installing the GBIC
Figure 2. GBIC Module
Do not attach Fibre Channel cables to the FC I/O adapter at this time. Also, do not reboot the HP NetServers at this time.
To part 2 of the HP NetServer Installation Guide.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
3 – Shared Storage Hardware Setup
Install the HP FC-AL Hub
1. Unpack the HP FC-AL Hub
a. Unpack and inspect the HP FC-AL hub for any damage that may have occurred during shipment.
b. Save the boxes and packing materials in case there is damage or anything needs to be reshipped at a future date.
c. Make sure all items shown in figure 3 are present. Contact your sales representative if items are missing.
FC-AL Hub Service
and User Manual
FC-AL hub
Power cord
Nylon retainer
FC port covers
FC-AL short-wave loopback
in each port
cable
NOTE: The long-wave hub
includes an additional loopback
cable for the long-wave port
Mounting ear
bracket
Rubber feet
Figure 3. HP FC-AL hub product contents
8
Download from Www.Somanuals.com. All Manuals Search And Download.
The front panel of the short-wave hub (HP A3724A) appears as follows:
2
4
10
6
1
3
7
8
9
5
1. Power LED
2. Fault LED
6. 10Base-T Port (reserved for future use)
7. MAC address (reserved for future use)
8. RS-232 port
3. Reset button
4. Fibre Channel connector (Port 1 indicated)
5. FC-AL short-wave ports and port LEDs
9. AC power connector
10. Port LED (Port 1 indicated)
Figure 4. HP FC-AL short-wave hub
The front panel of the long-wave hub (HP A4839A) appears as follows:
2 11
4
7
1
3
5
6
8
9
10
1. Power LED
2. Fault LED
3. Reset button
7. 10Base-T Port (reserved for future use)
8. MAC address (reserved for future use)
9. RS-232 port
4. Fibre Channel connector (Port 1 indicated)
5. FC-AL short-wave ports and port LEDs
6. FC-AL long-wave port and port LED
10. AC power connector
11. Port LED (Port 1 indicated)
Figure 5. HP FC-AL long-wave hub
9
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Verify HP FC-AL Hub Operation
Test the HP FC-AL hub and verify that it operates before mounting it in the cabinet (also called a rack).
a. Perform a self-test by connecting the short-wave loopback cable to a short-wave hub port, plugging the power cord
into the HP FC-AL hub, and then plugging the power cord into a power receptacle. The short-wave loopback cable
includes “50/125” as part of the identification information printed on the cable.The HP FC-AL hub does not have a
power switch.
If using an A4839A long-wave hub, also self-test the long-wave port with the long-wave loopback cable
(A4839-63001). The long-wave loopback cable includes “9/125” as part of the identification information printed on
the cable.
NOTE
The HP FC-AL hub’s power supply automatically adjusts to a range of 100 VAC ±10% and
240 VAC ±10%.
Interruptions to the HP FC-AL hub’s AC power source initiate a self-test. Make sure the power
source circuits are properly grounded before using the supplied power cord to connect the HP
FC-AL hub to the circuit.
b. The HP FC-AL hub runs the self-test each time the power cord is plugged in or the Reset button is pressed if a
loopback cable or a device is connected.
c. The HP FC-AL hub finishes the self-test in less than 15 seconds.
•
If the Fault LED (amber) stays on after self-test, the HP FC-AL hub failed. Contact your sales representative for
assistance.
•
If the Power LED does not light, contact your sales representative.
d. Verify the operation of individual ports by inserting the loopback cable into each port and observing that the port
status LED lights up.
e. Unplug the HP FC-AL hub and continue with the installation procedure.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Mount the HP FC-AL Hub into the Cabinet
The HP FC-AL hub mounts into the HP E3662A or E3662B 2.0m high, 19-inch wide, 220VAC, EIA cabinet (also called
a rack). The following procedure describes mounting an HP FC-AL hub with its front panel facing the rear of the
cabinet. The front of the HP FC-AL hub contains the 10 Fibre Channel connectors.
a. Record the serial number, located on the bottom of the HP FC-AL hub, before installing the HP FC-AL hub into the
cabinet.
b. Power down the cabinet and unplug it from the power source. Refer to the cabinet documentation for more
information. Make sure the cabinet is adequately secured and has enough space (1 EIA) for the HP FC-AL hub.
Remove filler panels as needed from the front of the cabinet and open the rear door.
c. Slide a sheet metal nut onto the outer column in the back of the cabinet, so the hole in the nut is aligned with the
hole at the selected EIA location on the column.
d. Insert one end of the left rail in the adjoining slot, so the hole in the rail lines up with the holes in the nut and column
(see figure 6).
e
Attach the other end of the rail to the inner column on the front of the cabinet using the same procedure and a second
sheet metal nut.
NOTE
Do NOT attach screws at this time.
Figure 6. Installing rails for the FC-AL hub into the cabinet
f. Repeat steps c, d, and e to install the right rail.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
g. Set the HP FC-AL hub on the cabinet. Align the hole in each mounting ear bracket with the holes in the assembled
rail, nut, and column, and insert a 10-32 x .625 machine screw. Securely tighten the screws (see figure 7).
Figure 7. Installing the HP FC-AL hub into the cabinet
h. The plenum shroud is a back cover that slides onto the HP FC-AL hub. Set the plenum shroud on the front side of
the cabinet. Align the holes in the brackets with the holes in the assembled rails and outer posts.
i. Secure the brackets to the posts with 10-32 x .625 machine screws (see figure 8).
Plenum shroud
Figure 8. Installing the plenum shroud
j. Reinstall filler panels over the plenum shroud.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 9. HP FC-AL hub correctly installed in a cabinet
If cascading HP FC-AL hubs are being used, install the second HP FC-AL hub, following the same steps used in
installing the first HP FC-AL hub.
Do not attach Fibre Channel cables or power cords to the HP FC-AL hub at this time. Also, do not power up the cabinet
at this time.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Install the HP Model 30/FC High Availability Disk Array
1. Check Power Requirements
Refer to the disk array DC power requirements in the Reference chapter of the Hewlett-Packard Model 30/FC High
Availability Disk Array Service Manual (part number A3661-90002) to make sure the installation site meets these
requirements.
The HP Model 30/FC High Availability Disk Array uses 200VAC to 240VAC nominal; 110VAC is not supported. One
power distribution unit (PDU) in the cabinet can provide sufficient power for one, two, or three disk arrays. The disk
array and HP FC-AL hub are connected to the PDU; the PDU is connected to an UPS.
Make sure the UPS is capable of supplying an amount of power equal to the sum of the VA units required to power all
the systems and peripherals installed in the cabinet.
Consider the type of PDU that is required. PDUs have power inlets and outlets that impinge on clearances necessary to
fully open the disk array’s fan pack door. Table 1 specifies the required PDUs for various hardware configurations
installed in one cabinet.
Table 1 – PDU Requirements
PDU part
number
PDU product
number
Description
Typical application Racking restrictions
E5929-63001 E5929A
- Universal PDU
C-19 outlet is for SPUs Must be racked on rails at or
- Ten C-13 and one C-19 requiring a 20-amp
above 4 EIAs to clear the
C-19 outlet.
outlets
connector.
- One C-20 inlet for
detachable cords
C-20 inlet facilitates a
universal set of
If the C-19 outlet is not
used, must be racked on
detachable power cords. rails at or above 1 EIA to
Typically, for external
UPS applications
clear the C-20 inlet.
E5931A
E5932A
- N. America 220 V PDU Attached to a 3.0 or 5.5 None
- Ten C-13 outlets
- Attached 3 m power
cord with L6-30P plug
- Europe 220 PDU
- Ten C-13 outlets
- Attached 3 m power
cord without plug
kva N. American UPS
Attached to a 3.0 or 5.5 None
kva European UPS
E4456-63001 E4456B
- N. America 220 V PDU C-19 outlet is for SPUs Must be racked on rails at or
- Ten C-13 and one C-19 requiring a 20-amp
above 4 EIAs to clear the
C-19 outlet.
outlets
connector.
- Attached power cord
with L6-20P plug
Power cord typical for
N. America wall outlet
connection.
If the C-19 outlet is not
used, must be racked on the
bottom of the rack without
rails.
E4457-63001 E4457B
- Europe 220 V PDU
C-19 outlet is for SPUs Must be racked on rails at or
- Ten C-13 and one C-19 requiring a 20-amp
above 4 EIAs to clear the
C-19 outlet.
outlets
connector.
- Attached power cord
without a plug
Power cord has stripped If the C-19 outlet is not
ends for attaching
localized plug.
used, can be racked on the
bottom of the rack without
rails.
C2786-63006 E4456A
C2786-63007 E4457A
- N. America
220 V PDU
None
- Ten C-13 outlets
- Attached power cord
with L6-20P plug
- Europe 220 V PDU
- Ten C-13 outlets
- Attached power cord
without plug
Power cord has stripped None
ends for attaching
localized plug.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
The HP Model 30/FC High Availability Disk Array is rated to draw approximately 5amps at 230VAC steady state
current for normal operation. However, when powered on, the disk array draws a heavy in-rush (surge) current (up to
115 amps for 10 to 12 ms) that could trip standard industrial circuit breakers.
Hewlett-Packard strongly recommends installing magnetic-type circuit breakers capable of handling large in-rush
currents for short durations (10 to 12 milliseconds), but rated adequately for steady state currents.
For European installations, Hewlett-Packard strongly recommends installing 20A circuit breakers, Type C or Type D per
IEC 898, or Type K per IEC 947-2.
All electrical wiring to the service point (plug) for the disk array should be sized adequately to carry the in-rush and
steady state currents shown above.
2. Unpack the HP Model 30/FC High Availability Disk Array
The HP Model 30/FC High Availability Disk Array must be installed into an HP E3662A or E3662B 2.0m high, 19-inch
wide, 220VAC, EIA cabinet (also called a rack) at the installation site.
The disk modules for the disk array are packaged in boxes separate from the disk array chassis. Each box containing disk
modules has a label imprinted with the chassis number of the disk array into which the disk modules should be installed.
The disk modules are shipped with the disk array and banded to the pallet. Boxes of cables and accessories are shipped
separately.
a. Move the disk array, disk modules, and boxes containing the cables and accessories to the cabinet where the
equipment will be installed.
b. Cut the plastic bands around the shipping carton and pallet.
WARNING
Wear protective glasses while cutting the plastic strapping bands. They are under tension; when
cut, they can spring back and cause serious eye injury.
c. Remove the shipping carton(s) containing the disk modules from the top of the disk array’s shipping carton.
d. Open the disk array’s shipping carton by cutting the tape over the seams.
e. Lift the shipping carton off the disk array.
f. Remove all foam strips from around the disk array.
WARNING
Do not lift the disk array chassis by the fan pack handle at the back of the disk array. Doing so can
damage the disk array.
The disk array is very heavy. Use extreme care when moving or lifting it. At least two persons are
needed to lift and safely install a disk array into a cabinet.
g. Remove the cardboard braces from the ends of the disk array. Keeping your hands under the bottom of the unit, lift
the disk array off the pallet. Place the unit on a suitably sturdy, anti-static work surface.
h. Remove the protective covering from the disk array.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
i. Remove the disk array’s front bezel by grasping its sides and pulling straight out. If the bezel is difficult to remove,
use a small standard screwdriver to carefully loosen the bezel at its four outside corners.
To remove front bezel,
grasp the sides of the panel
and pull straight out.
To install front bezel,
press panel onto ballstuds.
Ballstud
Figure 10. Removing the front bezel
3. Prepare the Cabinet
The HP Model 30/FC High Availability Disk Array requires 11 EIA units of space in the cabinet.
The hardware mounting kit (part number A3661-60006), which is shipped with the disk array, consists of:
–
–
–
–
2 rails (part number A3661-00002)
20 retaining screws (part number 2680-0278)
16 clip nuts (part number 0590-0804)
1 custom trim panel (part number A3661-00001)
a. Make sure the cabinet is powered down. Refer to the cabinet documentation for more information.
b. Remove any trim and open the doors of the cabinet. Refer to the cabinet documentation for more information.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
c. Attach the mounting rails to the cabinet as shown (see figure 11).
–
Determine the location in the cabinet where the disk array is to be mounted. The disk array should be mounted
in the lowest position available in the cabinet.
–
Install two clip nuts (A in figure 11) over the two holes in the front and back cabinet columns at the height
where the left rail is to be mounted.
–
–
Mount the left rail by inserting the tabs at the front and rear of the cabinet (B in figure 9).
Install the two screws (one on the front column and one on the rear column) to anchor the rail in the cabinet
(C in figure 11).
–
Install the right rail in the same manner.
A
B
C
Figure 11. Installing mounting rails for the disk array into the cabinet
d. Install the clip nuts.
–
Count up 14, 20, and 26 holes from the hole used to install the rail and slide clip nuts over these holes for the
front retaining screws. Perform these steps for both sides of the front of the cabinet, installing a total of six clip
nuts.
–
Count up five and six holes from the holes used to install the rear of the rails and install the clip nuts for the rear
retaining screws on both sides of the cabinet.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Install the HP Model 30/FC High Availability Disk Array in the Cabinet
a. Remove the fan pack from the back of the disk array.
–
–
–
–
–
Grasp the fan pack handle.
Press the lock/unlock button and hold it down.
Carefully swing the fan pack down.
Press the release latches in the direction shown.
Pull the fan pack away from the chassis.
CAUTION
Do not lift a fan pack by its handle as doing so can damage the fan pack.
Replace light
(amber)
Lock/unlock button
Holding module at
Back of
slight angle, slide it
away from chassis.
Be careful not to pull
power cord out of
socket.
storage system
ac power
cord
ac power
cord
release
latches
Figure 12. Removing the fan pack
18
Download from Www.Somanuals.com. All Manuals Search And Download.
b. Remove the battery backup unit (BBU) from the back of the disk array.
–
–
–
–
Locate the BBU. It is above the power supply units.
Grasp the BBU by inserting your thumbs in the holes and your forefingers into the latches.
Slide the latches inward and hold.
Pull the BBU out of the chassis.
Back of storage system
SP B
SP A
BBU
BBU
Figure 13. Location of the BBU
CAUTION
Use caution when removing the BBU. It is very heavy.
Figure 14. Removing the BBU
19
Download from Www.Somanuals.com. All Manuals Search And Download.
c. Remove the power supply units from the back of the disk array
–
–
–
–
Grasp a power supply unit by its handle.
Squeeze the latch toward the handle.
Pull the power supply unit out of the chassis.
Repeat for the other power supply units.
Figure 15. Removing a power supply unit
20
Download from Www.Somanuals.com. All Manuals Search And Download.
d. Mount the disk array chassis into the cabinet.
WARNING
The disk array is very heavy. Use extreme care when moving or lifting it. At least two persons are
needed to lift and safely install a disk array into a cabinet.
CAUTION
The disk array must be installed so that opening the fan pack door does not interfere with any plug
on the cabinet PDU, any cables, any PDUs, or any other devices.
–
–
–
Slide the chassis onto the rails and into the cabinet.
Secure the front of the chassis to the cabinet with six retaining screws.
Secure the rear of the chassis to the cabinet with four retaining screws.
Figure 16. Mounting the disk array into the cabinet
21
Download from Www.Somanuals.com. All Manuals Search And Download.
e. Unpack and install the disk modules.
CAUTION Handle disk modules very carefully as they can be damaged easily by shock and vibration.
Strap the ESD wrist strap to your wrist and ground it to the disk array chassis (or suitable ground).
Place the disk module on an ESD conductive sheet when it is removed from its carton. Use ESD
kit P/N 5182-4119 (supplied with each disk array).
Make sure each disk module’s label, which shows its slot ID (A0, for example), is present.
The disk modules must be installed in the slot that matches the slot ID on the label. For the slot ID numbers, refer to
the disk array chassis illustrations in chapter 1 of the Hewlett-Packard Model 30/FC High Availability Disk Array
Service Manual (A3661-90002). Make sure that all the disk slots contain disk modules or filler panels to ensure
proper cooling.
–
–
–
–
Observe anti-static precautions.
Locate the slot where the disk module is to be installed (see figure 17).
Write the slot number the disk is being installed into on the label affixed to the disk module; for example, A1.
Install the disk module gently but firmly by sliding it into the slot. Rough handling can damage the disk module.
Seat the disk module slowly into the connector.
Guide slot
Disk module’s
guide
Rail slot
Disk module’s
ESD wrist strap
rail
Figure 17. Installing a disk module
22
Download from Www.Somanuals.com. All Manuals Search And Download.
f. Replace the power supply units.
–
–
–
Locate the slot where the power supply unit is to be installed.
Slide each power supply unit into its slot while squeezing the latch until it engages the connector.
Press firmly until the power supply unit seats fully into the chassis.
Figure 18. Replacing a power supply unit
g. Replace the BBU.
–
–
–
Locate the slot where the BBU is to be installed.
Slide the BBU into the slot until it engages the backplane connector.
Press firmly until the BBU seats fully into the chassis and the latches lock.
h. Replace the fan pack.
CAUTION
The disk array must be installed so that opening the fan pack door does not interfere with any plug
on the cabinet PDU, any cables, any PDUs, or any other devices.
–
–
–
–
Push the fan pack hinge channels onto the chassis hinge pins.
Be sure latches seat over hinge pins.
Close the fan pack by carefully swinging it up.
Firmly press the fan pack against the disk array chassis until the lock/unlock button engages.
Holding module at
slight angle, slide it
onto hinge pins.
ac power
cord
Figure 19. Replacing the fan pack
23
Download from Www.Somanuals.com. All Manuals Search And Download.
i. Reinstall trim.
–
Install the 1/2 U filler panel (part number A3661-00003) to the bottom of the disk array’s front bezel using four
of the screws (part number 2680-0273) from the hardware mounting kit.
–
–
Reinstall the disk array’s front bezel.
Reinstall any trim removed from the cabinet and close the cabinet doors. Do not power up the cabinet at this
time.
5. Set the Fibre Channel ID for the SP in the Disk Array
Each HP Model 30/FC High Availability Disk Array can have two SPs (storage processor controllers), which are located
in the back of the disk array. In a basic cluster consisting of two HP NetServers, one HP FC-AL hub and one disk array,
the HP FC-AL hub will be connected to SP A of the disk array. SP A is on the left of the Fibre Channel Interconnect
PCA (Printed Circuit Assembly). The SP on the right, if it is present, is SP B.
The back of the disk array has two pairs of Fibre Channel address switches on the Fibre Channel Interconnect printed
circuit assembly (PCA) (see figure 20). One pair is used to set the Fibre Channel address for SP A. The other pair sets
the Fibre Channel address for SP B. The left switch in each pair has eight values (hexadecimal 0x0 through 0x7); the
right switch has 16 values (hexadecimal 0x0 through 0xF).
Most-significant
digit of FC ID
Least-significant
digit of FC ID
0
1
0
1
2
F
2
3
3
E
4
D
4
5
C
5
6
B
6
7
A
7
8
9
SP A’s FC ID
switches
SP B’s FC ID
switches
Figure 20. Fibre Channel ID switches
The Fibre Channel address is composed of two digits. The left digit (the high-order digit) is set by the left switch. The
right digit (the low-order digit) is set by the right switch.
Occasionally two or more ports in an FC arbitrated loop will arbitrate simultaneously. Priorities are decided according to
the loop IDs. The higher the loop ID, the higher the priority.
NOTE
Each SP requires a unique Fibre Channel address number.
Using table 2 as a guide, set the switches for the SP’s Fibre Channel address. Each Fibre Channel address should be set
to a unique value. For example, if the desired loop ID is 0x09, the left switch is set to 0 and the right switch is set to 9.
Valid loop IDs are from 0x00 to 0x7E (126 decimal) inclusive.
CAUTION
Do NOT use FC address 0x7E (126 decimal) because it will cause a system panic.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 2 – Fibre Channel Addresses
FC address (Loop ID)
FC address (Loop ID)
FC address (Loop ID)
(hexadecimal)
(decimal)
(hexadecimal)
2B
2C
2D
2E
2F
30
(decimal)
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
(hexadecimal)
(decimal)
00
0
55
85
01
1
56
86
02
2
57
87
03
3
58
88
04
4
59
89
05
5
5A
5B
5C
5D
5E
5F
60
90
91
92
93
94
95
96
06
6
31
32
33
34
35
36
37
38
07
7
08
8
09
9
0A
0B
0C
0D
0E
0F
10
11
12
13
14
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
61
97
62
98
39
63
99
3A
3B
3C
3D
3E
3F
40
41
42
43
44
64
65
66
67
68
69
6A
6B
6C
6D
6E
6F
70
71
72
73
74
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26
27
28
29
2A
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
75
76
77
78
79
7A
7B
7C
7D
7E
To install additional HP Model 30/FC High Availability Disk Arrays into the same cabinet, first verify that 11 EIA units
of space are available in the cabinet, then repeat steps 2 through 5. Be sure to set the Fibre Channel address of each SP in
each disk array to a unique number.
Do not attach Fibre Channel cables or power cords at this time. Also, do not power up the cabinet at this time.
To part 3 of the HP NetServer Installation Guide.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
4 – Cluster Cabling and Setup
1. Plan the HP FC-AL Hub Connections
The HP NetServers should be powered down when making the FC-AL connections to the FC I/O adapters. Power down
the HP NetServers if they are not already powered down. The HP Model 30/FC High Availability Disk Array and the
cabinet should still be powered down at this time.
CAUTION
Incorrect wiring can lead to problems, such as devices left off the loop and inaccessible by the HP
NetServer. Follow the guidelines below before starting.
a. Review the hardware address of each FC-AL device to be connected to the HP FC-AL hub, and make sure each ID
is unique. Duplicate IDs on the loop can cause problems. In addition, each device has its own factory-assigned
unique worldwide name.
b. Verify that the connections between the HP FC-AL hub port and the disk array or the FC I/O adapter in the HP
NetServers are of the same wave type and speed. For example, plan to connect a short-wave port on the HP FC-AL
hub to a short-wave port on an FC-AL device.
c. Document the planned connections in a cabling map.
2. How to Make an FC-AL Connection
To connect a fiber optic cable to an HP FC-AL hub, find any available, appropriate Fibre Channel port on the HP
FC-AL hub, remove the FC port cover, and connect the fibre optic cable. No priority or hierarchy is assigned to the
connectors on the HP FC-AL hub.
The cable connector is keyed to avoid incorrect installation. Short wave cables should be used to connect short-wave
ports. A long-wave cable should be used to connect the long-wave ports of cascading long-wave hubs.
NOTE
Fiber optic cables and connectors are extremely fragile. Avoid twisting or bending the cable to
less than a 3 cm radius.
If using a single short-wave hub, FC-AL connections can be made to any of the 10 short-wave ports of the HP FC-AL
hub. That is, the FC I/O adapters and the disk array can be connected to any ports on the HP FC-AL hub.
If using cascading short-wave hubs, connections between HP FC-AL hubs and from the HP FC-AL hub to the FC I/O
adapters and the disk array can be made to any of the 10 ports on the HP FC-AL hub.
If using a single long-wave hub, FC I/O adapters and the disk array can be connected to Port 1 through Port 9 (the
leftmost nine, short-wave ports). Port 10 (the rightmost, long-wave port) should not be used to connect these devices.
If using cascading long-wave hubs, the two HP FC-AL hubs should be connected to each other using the long-wave
Port 10. Port 1 through Port 9, the short-wave ports, can be used to connect FC I/O adapters and the disk array.
Figure 21. Connecting a fiber optic cable to a Fibre Channel connector
26
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTE
To protect hub ports, port covers should remain installed in all unused ports.
3. Connect Cascading HP FC-AL Hubs
If using cascading hubs, connect the two HP FC-AL hubs to each other.
•
If connecting short-wave hubs, refer to figure 28.
If connecting long-wave hubs, refer to figure 29.
•
–
When installing long-wave cascading hubs (HP A4839A), make sure the long-wave port (Port 10) is connected only
to the long-wave port (Port 10) on the other long-wave hub.
4. Connect the FC I/O Adapter to the HP FC-AL Hub
a. Connect the HP FC-AL hub to the FC I/O adapter on each HP NetServer.
Figure 22. An example of an HP FC-AL hub connected to an HP NetServer LXr Pro8
Figure 23. An example of an HP FC-AL hub connected to two HP NetServer LXr Pro8s
27
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Connect the HP Model 30/FC High Availability Disk Array to the HP FC-AL Hub
The external Fibre Channel connectors link the disk array to an HP FC-AL hub through fiber optic cables. These
connectors are located at the back of the disk array, on the Fibre Channel Interconnect (printed circuit assembly). The
Fibre Channel connectors are located above the SPs. One Fibre Channel connector is associated with each SP. The HP
Model 30/FC High Availability Disk Array can have one or two SPs: SP A and SP B (see figure 24). If connecting the
disk array to a single HP FC-AL hub, make the connection to SP A.
FC address
switches-
SP A
FC
connectors
SP A
FC address
switches-
SP B
FC
connectors
SP B
FC
interface
PCA
SP-A
SP-B
BBU
Figure 24. Fibre Channel connector locations
Figure 25. Connecting the HP FC-AL hub to the disk array
28
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 26. Example of a cluster with two HP NetServer LXr Pro8s, one HP FC-AL hub and one disk array
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 27. Example of a cluster with two HP NetServer LXr Pro8s and cascaded hubs
30
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Verify FC-AL Cabling
Correct cabling example, HP FC-AL short-wave hub (HP A3724A)
In a cascaded configuration of HP FC-AL short-wave hubs, use a short-wave cable to connect any port on the first HP
FC-AL hub to any port on the second HP FC-AL hub. In the following example, Port 1 on Hub A connects to FC-AL
Device 1; Port 10 of Hub A connects to Port 1 of Hub B; and Port 10 on Hub B connects to FC-AL Device 2. Any short-
wave FC-AL device or hub can connect to Port 10 of a short-wave hub.
Hub A
Hub B
To Device 2
To Device 1
Figure 28. Cascaded HP FC-AL short-wave hub (HP A3724A) configuration
Correct cabling example, HP FC-AL long-wave hub (HP A48394A)
In a cascaded configuration of HP FC-AL long-wave hubs, use a long-wave cable to connect the long-wave port (Port
10) on the first HP FC-AL hub to the long-wave port (Port 10) on the second HP FC-AL hub. In the following example,
Port 1 on Hub A connects to FC-AL Device 1; Port 10 of Hub A connects to Port 10 of Hub B and Port 1 on Hub B
connects to FC-AL Device 2. This is the only correct way to cascade HP FC-AL long-wave hubs.
Hub A
Hub B
To Device 1
To Device 2
Figure 29. Cascaded HP FC-AL long-wave hub (HP A4839A) configuration
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Incorrect cabling examples
Do NOT cable together two ports on the same HP FC-AL hub. Ports between the two connections will be eliminated
from the FC-AL loop.
Figure 30. Incorrect cabling example: connected ports on the same HP FC-AL hub
Do NOT leave cables that are connected to the HP FC-AL hub disconnected at the opposite end of the cable.
Figure 31. Incorrect cabling example: disconnected cable
Do NOT attach more than one cable between any two HP FC-AL hubs.
Figure 32. Incorrect cabling example: more than one cable connection between HP FC-AL hubs
Attach HP FC-AL long-wave hubs only from the long-wave port (Port 10) of one long-wave hub to the long-wave port
(Port 10) of another long-wave hub. Do NOT connect any long-wave FC-AL devices to long-wave hubs.
Hub A
Hub B
To Device 1
To Device 2
Figure 33. Incorrect cabling example: long-wave port connections to wrong device/port
In the above example, the long-wave port (Port 10) of Hub A is incorrectly connected to Port 1, a short-wave port, on
Hub B. A device other than another long-wave hub is attached to the long-wave port (Port 10) of Hub B. The long-wave
port of Hub A should be connected to the long-wave port of Hub B.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
Nonsupported cabling example
Connecting an HP FC-AL hub to more than one other HP FC-AL hub is NOT a supported configuration.
Figure 34. Non-supported cabling example: more than two HP FC-AL hubs connected
Do not attach power cords or power up the disk array or the cabinet at this time.
To part 4 of the HP NetServer Installation Guide.
33
Download from Www.Somanuals.com. All Manuals Search And Download.
5 – HP NetServer Software Setup
To part 5 of the HP NetServer Installation Guide.
34
Download from Www.Somanuals.com. All Manuals Search And Download.
6 – Shared Storage Software Setup
Install the Fibre Channel Driver on Windows NT
The Hewlett-Packard Model 30/FC Disk Array and the cabinet should be powered down at this time.
To install the Fibre Channel driver Windows NT, perform the following steps on each HP NetServer in the cluster:
a. Power up the HP NetServer if it is not already powered up.
b. Start Windows NT if it is not running and log into an account with administrative privileges.
c. Insert the Hewlett-Packard driver diskette into the floppy drive.
d. From the Start bar, select Settings.
e. From the Settings menu, click Control Panel.
f. From the Control Panel window, double-click SCSI Adapters.
g. From the SCSI Adapters window, click the Drivers tab.
h. From the Drivers window, click Add.
i. Click Have Disk.
j. From the floppy disk drive, click HP HHBA-5000X Fibre Channel Host Controller.
k. Click OK.
When the installation is complete, remove the diskette, shut down Windows NT, and, without powering up the disk
array, reboot the HP NetServer to load the driver.
Power down the HP NetServer.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Power Up the HP Model 30/FC High Availability Disk Array
1. Connect the Disk Array’s Power Cord
NOTE
The correct right-angle power cord must be used. If an incorrect power cord is used, the fan pack
cannot be opened without powering down the disk array and disconnecting the power cord.
a. Make sure the disk array’s power switch is in the off position, then connect the correct right-angle power cord to the
disk array.
b. Plug the other end of the power cord into one of the power outlets in the cabinet’s PDU.
Back of storage system
A. Push power switch to
OFF (0) position.
B. Plug power cord into
power connector.
Note: Fan not shown
for clarity
Figure 35. Connecting the power cord (typical)
2. Connect the HP FC-AL Hub’s Power Cord
a. Connect the power cord to the HP FC-AL hub.
b. Plug the other end of the power cord into one of the power outlets in the PDU.
c. If the installation uses cascading HP FC-AL hubs, connect a power cord to the second HP FC-AL hub and plug it
into the PDU.
3. Power Up the Cabinet
a. Connect the cabinet’s power cord to the power source.
b. Turn the main power switch at the front of the cabinet ON.
36
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Power Up the Disk Array
Turn on the disk array’s power by setting the POWER switch on the back of the unit to ON. The green POWER-ON
LED on the front of the disk array will light up and the fans will rotate.
On a disk array fully loaded with 30 disk modules, allow 8 to 10 minutes for all the disk modules to spin up.
If the BUSY LEDs on the disk drive modules do not light up, check that the disk array’s power cord is properly installed
and connected to the cabinet’s PDU.
Front of storage system
POWER
Back of storage
system
Note:
Fan not shown
for clarity
Figure 36. Powering up the disk array
5. Power Up the HP NetServers
When the disk array is fully powered up, power up the HP NetServers. After powering up the HP NetServers, verify the
FC I/O adapter, GBIC, and cable installation on each HP NetServer in the cluster by looking at the two LEDs on the FC
I/O adapter. If the LED on the right is on, the FC-AL is complete. If the LED on the left is on, data is being transferred.
37
Download from Www.Somanuals.com. All Manuals Search And Download.
Install the HP Model 30/FC High Availability Disk Array Software
The HP Model 30/FC High Availability Disk Array software consists of the following host-resident utility:
•
ArrayGUIdeTM
ArrayGUIde is a software tool for managing HP Model 30/FC High Availability Disk Arrays connected to HP
NetServers. ArrayGUIde consists of a graphical user interface (GUI), called Arraymgr, and a storage system agent,
called Agent.
–
–
Arraymgr is used to configure disk arrays and monitor their status from any host on a TCP/IP network.
Agent runs in the background on an HP NetServer.
Install this software utility by following the detailed instructions included in the NT Addendum, Hewlett-Packard Model
30/FC High Availability Disk Array User’s Guide and Service Manual Addendum for Microsoft Windows NT 4.0
(part number A3661-90019). The disk array should be powered up while this utility is installed.
1. To install ArrayGUIde, see the Installing ArrayGUIde section of chapter 8 of the NT Addendum.
38
Download from Www.Somanuals.com. All Manuals Search And Download.
Set the HP Model 30/FC High Availability Disk Array Operating
Mode
The disk array is shipped from the factory with auto-trespass, which is one of the host mode parameters, turned on.
Auto-trespass must be turned off for the disk array to operate correctly on the Microsoft Windows NT operating system.
1. Turn off Auto-Trespass
a. Make sure that ArrayGUIde has been installed onto the HP NetServers.
b. From the Start bar, select Programs.
b. Click Windows NT Explorer.
c. Double-click Program Files.
d. Double-click CLARiiON.
e. Double-click Agent.
f. Double-click the program file SetHM_a.exe.
g. Using this program to change the host mode parameters causes all disk arrays attached to the HP NetServers to
reboot automatically.
To part 6 of the HP NetServer Installation Guide.
39