Generac Power Systems Portable Generator QT04524 User Manual

Liquid Cooled  
Gas Engine  
Generator Sets  
Standby Power Rating  
45 kW 60 Hz CA  
South Coast Air Quality Management District (SCAQMD)  
Emission Certified For Standby Generator Application  
Whisper-Test  
Low Speed Exercise  
58 dB(A) at 23 feet  
GENERAC 2.4L ENGINE  
Naturally Aspirated  
Gaseous Fueled  
UL 2200 Listed  
Transfer Switch is sold separately  
STANDARD EQUIPMENT  
UV/Ozone resistant hoses  
Watertight state of the art electrical connectors  
Mainline circuit breaker  
Radiator drain extension  
Battery charge alternator  
2 Amp static battery charger  
Battery rack and battery cables  
Fan and belt guards  
All input connections in one single area  
High coolant temperature shutdown  
Low oil pressure shutdown  
Low coolant level automatic shutdown  
Overspeed automatic shutdown  
Crank timer  
Exercise timer  
Oil drain extension  
Cool flow radiator  
Closed coolant recovery system  
Isochronous governor  
Flex fuel line pigtail  
FEATURES  
State of the art control system with R-Series digital control panel  
Rodent proof construction  
High efficiency, low distortion Generac designed alternator  
Vibration isolated from mounting base  
Matching Generac transfer switches engineered and tested to  
work as a system  
All components easily accessible for maintenance  
Electrostatically applied textured powder paint  
Innovative design and fully prototype tested  
UL 2200 Listed  
Solid state frequency compensated  
voltage regulator  
Dynamic and static battery charger  
Sound attenuated acoustically designed enclosure  
Whisper-Test™ for low noise level exercise  
Acoustically designed engine cooling system  
High flow low noise factory engineered exhaust system  
COMMERCIAL SERIES  
Download from Www.Somanuals.com. All Manuals Search And Download.  
COMMERCIAL 45 kW CA  
COMMERCIAL SERIES  
OPERATING DATA  
COMMERCIAL 45 kW CA  
45  
KW RATING  
ENGINE SIZE  
2.4 Liter  
GENERATOR OUTPUT VOLTAGE/KW - 60Hz  
120/208V, 3-phase, 0.8 pf  
120/240V, 3-phase, 0.8 pf  
KW  
45  
45  
45  
AMP  
156.3  
135.4  
67.7  
CB Size  
175  
150  
80  
277/480V, 3-phase, 0.8 pf  
GENERATOR LOCKED ROTOR KVA  
AVAILABLE @ VOLTAGE DIP OF 35%  
208 3-phase  
100  
110  
480V 3-phase  
ENGINE FUEL CONSUMPTION (Natural Gas) (Propane)  
Natural Gas  
(ft3/hr.)  
102  
Propane  
(gal/hr.)  
1.11  
2.12  
4.07  
5.67  
cu ft/hr  
Exercise cycle  
40.4  
77.1  
148  
206.3  
286  
25% of rated load  
50% of rated load  
75% of rated load  
100% of rated load  
194  
373  
520  
720  
7.86  
ENGINE COOLING  
Air flow (inlet air including alternator and combustion air)  
System coolant capacity  
Heat rejection to coolant  
Max. operating air temp. on radiator  
Max. ambient temperature  
ft3/min.  
US gal.  
BTU/hr.  
°C (°F)  
°C (°F)  
2,725  
3.0  
173,000  
60 (150)  
50 (140)  
COMBUSTION AIR REQUIREMENTS  
Flow at rated power 60 Hz  
cfm  
144  
SOUND EMISSIONS IN DBA  
Exercising at 7 meters  
Full load at 7 meters  
58  
72  
EXHAUST  
Exhaust flow at rated output 60 Hz  
Exhaust temp. at muffler outlet  
cfm  
°F  
429  
1150  
ENGINE PARAMETERS  
Rated synchronous RPM  
HP at rated KW  
60 Hz  
60 Hz  
3600  
71  
POWER ADJUSTMENT FOR AMBIENT CONDITIONS  
Temperature Deration  
3% for every 10 °C above - °C  
1.65% for every 10 °F above - °F  
25  
77  
Altitude Deration  
1% for every 100 m above - m  
3% for every 1000 ft. above - ft.  
183  
600  
RATING: All single phase units are rated at 1.0 power factor. STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to  
varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change  
without notice. Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTERCONNECTIONS  
COMMERCIAL 45 kW CA  
INSTALLATION LAYOUT  
COMMERCIAL SERIES  
UNIT WEIGHT: Steel 1464 lbs.  
®
GENERAC POWER SYSTEMS, INC. • P.O. BOX 297 • WHITEWATER, WI 53190  
www.guardiangenerators.com  
Bulletin 0174970SBY / Printed in USA 07.07  
© 2007 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Eiki Home Theater System EIP D450 User Manual
Excalibur electronic Handheld Game System 455D User Manual
Foster Refrigerator FHG 2L User Manual
Franke Consumer Products Oven FHPL 301 1CO User Manual
Fujitsu Printer FTP 641MCL301 User Manual
Fujitsu Scanner 600C User Manual
Fundex Games Board Games 3 Great Games User Manual
GE Air Conditioner AZ41E09DAC User Manual
GE Flat Panel Television JVB98SH User Manual
Gigabyte Computer Hardware GA K8NS User Manual