		 INSTALLATION MANUAL   
					WS06   
					
					GE Switch:   
					ASR-4173-500   
					(UL Recognized   
					IMPORTANT   
					Component)   
					Top   
					Must use this wiring diagram for installation.   
					Do not use Thermador wiring diagram.   
					Switch: Red   
					Low speed   
					LO   
					HI   
					WARNING   
					OFF   
					MED   
					Electrical wiring should be done by a qualified person(s)   
					Switch: Yellow   
					in accordance with all applicable codes and standards,   
					including fire-rated construction. An unqualified person   
					doing the work could result in fire, electric shock or injury.   
					Switch: Black   
					High speed   
					This switch uses 120 V AC, Max 16 Amp. Do not connect   
					to other voltage or over current rate since fire, electric   
					shock or damage could result.   
					Switch: Blue   
					Medium speed   
					Be sure to switch power OFF at service panel before   
					wiring.   
					WHITE   
					/NEUTRAL   
					BLACK   
					/120V AC   
					< CONNECTING POWER SUPPLY WIRES >   
					1. A 2-1/2" deep Wall Box must be used to allow space for   
					wire connections between switch and 120 volt Power   
					Input Leads.   
					2.   
					Connect the electrical wires in accordance with   
					wiring diagram (figure 1).   
					Connect wires tightly and securely using wire   
					connectors (not supplied).   
					3.   
					Attach the wall plate, and secure with 2 screws.   
					4. Turn on the electrical circuit to the power unit. Check   
					the ventilating functions at each speed control   
					positions. Make sure that the range hood has no   
					abnormal noises and/or vibration.   
					From   
					Blower Moter   
					< Connection Diagram >   
					FIG 1   
					Your installation is now complete.   
					If you should require service or replacement   
					parts on your ventilation system.   
					contact:   
					Motor Green or   
					Bare Ground Wire   
					- Grounded to   
					Wall Box   
					2-1/2" Deep Wall Box   
					(must be grounded)   
					Fuji Industrial USA,Inc.   
					16300 Christensen Rd, #212 Seattle, WA 98188   
					1-888-547-9880   
					Bowers #52 or Equivalent   
					FIG 2   
					READ AND SAVE THESE INSTRUCTIONS.   
					Keep this manual in a convenient place for future reference.   