Super Runner Series Electric
SR114E
NON-CE &
Dean, a member of the Commercial Food Equipment Service Association, recommends using
CFESA Certified Technicians.
* 8 1 9 6 0 1 0 *
24-Hour Service Hotline 1-800-551-8633
FEB 2007
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNING
No structural material on the fryer should be altered or removed to accommodate placement of
the fryer under a hood. Questions? Call the Frymaster Dean Service Hotline at 1-800-551-8633.
DANGER
Adequate means must be provided to limit the movement of this appliance without depending on
or transmitting stress to the electrical conduit. A restraint kit is provided with the fryer. If the
restraint kit is missing contact your local Frymaster Factory Authorized Service Center (FASC)
for part number 826-0900.
ii
Download from Www.Somanuals.com. All Manuals Search And Download.
SUPER RUNNER SERIES ELECTRIC FRYERS
CHAPTER 1: INSTALLATION INSTRUCTIONS
1.1 Safety Information
Before attempting to operate your unit, read the instructions in this manual thoroughly. Throughout this manual you will
find notations enclosed in double-bordered boxes with the symbol The information contained in the box concerns
.
actions or conditions that may cause or result in injury to personnel or damage to your system, and/or cause your system
to malfunction.
1.2 General Installation Instructions
NOTICE
This appliance is only for professional use and shall be used by qualified personnel only.
NOTICE
If this equipment is wired directly into the electrical power supply, a means for disconnection from the
supply having a contact separation of at least 3-mm in all poles must be incorporated in the fixed
wiring.
NOTICE
This equipment must be positioned so that the plug is accessible unless other means for
disconnection from the power supply (e.g., a circuit breaker) is provided.
NOTICE
If this appliance is permanently connected to fixed wiring, it must be connected by means of copper
wires having a temperature rating of not less than 194°F (90°C).
NOTICE
If the electrical power supply cord is damaged, it must be replaced by a Frymaster Dean Factory
Authorized Service Center technician or a similarly qualified person in order to avoid a hazard.
DANGER
This appliance must be connected to a power supply having the same voltage and phase as specified
on the rating plate located on the inside of the appliance door.
DANGER
All wiring connections for this appliance must be made in accordance with the wiring diagram(s)
furnished with the appliance. Refer to the wiring diagram(s) affixed to the inside of the appliance door
when installing or servicing this equipment.
DANGER
Frymaster Dean appliances equipped with legs are for stationary installations. Appliances fitted with
legs must be lifted during movement to avoid damage to the appliance and bodily injury. For movable
installations, optional equipment casters must be used. Questions? Call 1-800-551-8633.
DANGER
Single fryers must be restrained to prevent tipping when installed in order to avoid the splashing of
hot liquid. The means of restraint may be the manner of installation, such as connection to battery of
appliances or installing the fryer in an alcove, or by separate means, such as straps or chains.
DANGER
Do not attach an apron drainboard to a single unit. The appliance may become unstable, tip over, and
cause injury. The appliance area must be free and clear of combustible material at all times.
1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
SUPER RUNNER SERIES ELECTRIC FRYERS
CHAPTER 1: INSTALLATION INSTRUCTIONS
CLEARANCE AND VENTILATION
This fryer must be installed with a 6-inch (150-mm) clearance at both sides and back when installed adjacent to
combustible construction. No clearance is required when installed adjacent to non-combustible construction.
minimum of 24-inches (600-mm) clearance should be provided at the front of the fryer.
A
INSTALLATION
For units equipped with legs: Lift the unit and move it into its final position. Do not drag or push the fryer into position.
Doing so may damage the legs. Level the unit front to back and side to side. If the fryer is not level, the unit will not
function efficiently.
A. Adjust leg height with an adjustable or 1-1/16-inch (27-mm) open-end wrench by turning the hexagon-shaped foot
on the bottom of the leg. NOTE: The foot is for minor leg height adjustment only. Do not adjust outward more
than ¾-inch (19-mm).
B. When leveling the unit, the leg body should be held firmly to keep the leg from bending or rotating while turning the
foot to the required height.
For units equipped with casters: Roll the unit into its final position and lock the front casters.
When the fryer is leveled in its final position, install the restraints provided with the unit to limit its movement so
that it does not depend on or transmit stress to the electrical conduit or connection. Install the restraints in
accordance with the provided instructions (see illustration below). If the restraints are disconnected for service or
other reasons, they must be reconnected before the fryer is used.
1.3 Power Requirements
Use copper wire ONLY suitable for at least 194°F (90°C)
MINIMUM WIRE
WIRE
SERVICE
AMPS
(per leg)
MODEL
VOLTAGE
PHASE
SIZE
AWG
mm
14 kW
14 kW
14 kW
14 kW
14 kW
208
208
240
240
230/400
Single
3
3
3
3
4
4
8
4
8
6
(5.83)
(4.11)
(5.19)
(3.26)
(4.11)
68
39
59
34
21
3
Single
3
3
DANGER
The electrical power supply for this appliance MUST be the same as indicated on the rating and serial
number plate located on the inside of the fryer door.
DANGER
This appliance MUST be connected to the voltage and phase specified on the rating and serial
number plate located inside the fryer door.
DANGER
All wiring connections for this appliance MUST be made in accordance with the wiring diagrams
furnished with the equipment. Wiring diagrams are located inside the fryer door.
1-2
Download from Www.Somanuals.com. All Manuals Search And Download.
SUPER RUNNER SERIES ELECTRIC FRYERS
CHAPTER 2: OPERATION
2.1 Initial Startup
Wash the unit and accessories thoroughly with hot, soapy
water to remove any film residue, dust or debris. Rinse and
wipe dry. Close the drain valve completely. Ensure the
thermostat and high-limit thermostat sensing bulbs inside
the frypot are securely seated in the holding clamp and that
the clamp screws are secure (see photo at right).
Thermostat
Probe
High-Limit
Setup
WARNING
Fill the frypot to the bottom OIL LEVEL line with vegetable oil or shortening before pressing the
ON/OFF switch to the "ON" position. Failure to do so could damage the frypot and/or the heating
elements.
WARNING
NEVER set a complete block of solid shortening on top of heating elements. To do so will damage
the elements and increase the potential for flash-point shortening temperatures and subsequent fire.
1. Fill the frypot with vegetable oil to the bottom OIL LEVEL line located on the rear of the frypot. This will allow for
oil expansion as heat is applied. Do not fill cold oil any higher than the bottom line; overflow may occur as heat
expands the oil. If solid shortening is used, carefully pack solid shortening into the bottom of the frypot, below,
between and around the elements. Use extreme care not to damage the elements or sensing bulbs when packing the
shortening into the frypot. Ensure the elements are completely covered with shortening prior to engaging power
switch. Never insert a solid block of shortening into frypot on top of the elements. Hot spots and element damage
will occur, and the potential for flash-fire increases.
2. Ensure that the power cord is plugged into the appropriate receptacle. Verify that the face of the plug is flush with
the outlet plate, with no portion of the prongs visible.
3. Set the thermostat dial to the desired temperature. Turn the fryer power switch on and allow the oil to come to
operating temperature. If the fryer temperature exceeds 435°F (218°C) [410°F (210°C)], the over-temperature
protection circuit will trip. Allow the fryer to remain off for 30 minutes before resetting the high-limit switch.
Contact a service agent if the problem persists.
High-Limit
Reset
Thermostat
Control
4. Ensure that the oil/shortening level is at the top OIL LEVEL line when the fryer reaches operating temperature (the
indicator light will cycle on and off). It may be necessary to add oil or shortening to bring the level up to the proper
mark. If solid shortening is used, it may be necessary to turn the power switch off, and then back on, as the
shortening melts, to prevent hot spots.
2-1
Download from Www.Somanuals.com. All Manuals Search And Download.
SUPER RUNNER SERIES ELECTRIC FRYERS
CHAPTER 2: OPERATION
Shutdown
1. Press the ON/OFF switch to the "OFF" position.
2. Filter oil or shortening and clean the fryer.
3. Place the frypot covers on frypots.
2.2 Daily Operation
1. Do not allow grease to accumulate or harden on the frame or body of the fryer. Clean the fryer inside and out with a
solution of detergent and hot water daily.
2. Filter the cooking oil by draining the frypot through a filter cone at least daily. After the oil has been drained from
the frypot, remove any residue from the pot, using a scraper if necessary. Use care not to damage the elements or
sensor bulbs when removing residue from the frypot.
3. Clean the frypot at least once each week by filling it to just below the upper oil level mark with water. Add one cup
of detergent and bring the solution to a boil. Allow the solution to simmer for 10-15 minutes, then drain and rinse
the frypot with clean water twice. Add ¼ cup of white vinegar to the last rinse to neutralize any alkalinity remaining
from the detergent. Wipe the frypot surfaces with a dry towel before refilling with cooking oil. If the fryer is not to
be used immediately after cleaning, it is suggested that the inside of the frypot be wiped down with a light coat of
cooking oil to prevent rust.
2.3 Recommended Spare Parts
DESCRIPTION
Temperature Probe
High-Limit Thermostat
High-Limit Thermostat CE
Transformer (208/222/230/240)
Relay (12VDC)
Element, 208V
Element, 240V
Element, 230V
Light, Heat Indicator- White
Leg, 6-inch
PART #
807-1568
807-3559
807-3560
807-1999
807-1683
807-3978
807-3979
807-4340
807-1525
810-2053
810-0356
810-0357
826-1095
826-0900
Caster, 5-inch w/o Brake
Caster, 5-inch w/Brake
Strap Restraint Kit (Leg-Equipped Units)
Chain Restraint Kit (Caster-Equipped Units)
2-2
Download from Www.Somanuals.com. All Manuals Search And Download.
SUPER RUNNER SERIES ELECTRIC FRYERS
CHAPTER 2: OPERATION
2.4.1 Wiring Diagram Single Phase
2-3
Download from Www.Somanuals.com. All Manuals Search And Download.
SUPER RUNNER SERIES ELECTRIC FRYERS
CHAPTER 2: OPERATION
2.4.2 Wiring Diagram 3-Phase
W10C BLK
ELEMENTS
LIGHT
HIGH LIMIT
W11C BLK
COM
3
RELAY
W22C BLK
W24C BLU
1
2
NC
5
NO
4
W23C YEL
W27C BLK
W25C BLK
W26C BLK
W28C BLK
TRANSFORMER
WHT
1
2
4
9
5
8
6
7
RED
BLK
L1
L2
L3
L2
L1
L3
12 11 10
W9C BLU
W8C BLU
W7C BLU
W22C BLK
W21C BLK
W23C YEL
W24C BLU
W13C BRN
W15C RED
W17C WHT
FRAME
W18C BLU
W20C RED
W19C WHT
RED
WHT
1
2
GROUND
TEMP PROBE
ON/OFF
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15
8051513A
2-4
Download from Www.Somanuals.com. All Manuals Search And Download.
SUPER RUNNER SERIES ELECTRIC FRYERS
CHAPTER 2: OPERATION
2.4.3 Wiring Diagram 3-Phase WYE
ELEMENTS
LIGHT
HIGH LIMIT
RELAY
1
2
NO
COM 3
4
NC
5
TRANSFORMER
1
2
3
4
5
6
7
PRIMARY (LINE)
SECONDARY (LOAD)
N
N
N
L1
L2
L3
12
11
10
9
8
FRAME
1
2
TEMP PROBE
ON/OFF
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
8051586A
2-5
Download from Www.Somanuals.com. All Manuals Search And Download.
THIS PAGE INTENTIONALLY LEFT BLANK.
Download from Www.Somanuals.com. All Manuals Search And Download.
Dean, 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000
Shipping Address: 8700 Line Avenue, Shreveport, Louisiana 71106
TEL 1-318-865-1711
FAX (Parts) 1-318-219-7140
FAX (Tech Support) 1-318-219-7135
Price: $8.00
819-6010
PRINTED IN THE UNITED STATES
FEB 2007
Download from Www.Somanuals.com. All Manuals Search And Download.
|