installation guide and user manual
“Log Burner Technology”
Saturnus 8
NL-8448 CC Heerenveen
NL-8440 AE Heerenveen
Postbus 219
T. +31(0)513 656500
F. +31(0)513 656501
Download from Www.Somanuals.com. All Manuals Search And Download.
UK/IRL
UK/IRL
1. INTRODUCTION
2. SAFETY AND GENERAL
INFORMATION
Note: these instructions should be read carefully and retained for
future reference.
Please leave these instructions with the user.
Before installation, ensure that the local distribution conditions
(identification of the type of gas and pressure) and the adjustment of
the appliance are compatible.
This guide is concerning the following types of appliances:
Widescreen interior:
Roundscreen interior:
MV100 interior:
Types Silence and Feeling
Type Misty
This gas appliance is factory set and shall not be adjusted by the
installer.
Type Whisper
MV110 interior:
Types Spectra Nova and Cadra Nova
This appliance does not contain any component manufactured from
asbestos or any asbestos related products.
Special features:
The pilot and flame sensing device fitted to this fire is also a safety
device. If for any reason any part of the pilot assembly is to be
replaced the entire assembly including the pilot burner, thermocouple,
electrode and injector must be exchanged complete for a pilot assembly
from the original manufacturer only.
- Realistic flame and glow effect because of the "Log burner"
technology.
- Room sealed appliance, inlet and outlet are led to the outside
using a natural draught concentric pipe system (100 mm/150 mm)
(no power fan required). No additional ventilation required.
Ventilation
This appliance is room-sealed and doesn't require purpose provided
ventilation.
- Air supply and flue-gases go to outside atmosphere through wall or
roof. A maximum horizontal extension of 6 meters is possible.
- Remote Control option on all appliances.
2.1 General safety
- Meets the essential requirements of the European Gas Appliance
Directive (GAD) and carries the CE mark.
It is the law in the UK that all gas appliances, are installed by a
competent person in accordance with the Gas Safety (Installation and
Use) Regulations (as amended), the relevant British Standards for
Installation work, Building Regulations, Codes of Practice and the
manufacturers instructions.
The installation should also be carried out in accordance with the
following where relevant:
BS5871 Part1
BS5440 Parts 1 & 2
BS1251.
Building Regulations Document J (as applicable).
2
3
Download from Www.Somanuals.com. All Manuals Search And Download.
UK/IRL
UK/IRL
3. INSTALLATION REQUIREMENTS
Building Regulations and Standards issued as relevant by the
Department of the Environment or the Scottish Development
Department.
Note:
Since the appliance is a source of heat, circulation of air occurs.
Therefore it is of importance that you do not use the appliance
shortly after a renovation of the home. Because of the natural
circulation of air, moist and volatile components from paint, building
materials, carpet etc. will be attracted. These components can settle
themselves down onto cold surfaces in the form of soot.
In the Republic of Ireland installation should be carried out in
accordance with IS813, ICP3, IS327, Building Regulations, Codes of
Practice, the manufacturers instructions and any other rules in force.
Failure to comply with the above could leave the installer liable to
prosecution and invalidate the appliance warranty.
As on all heat producing appliances, soft furnishings such as blown
vinyl wallpaper placed too near to the appliance may become
scorched or discoloured. This should be born in mind when installing
the appliance.
Safety instructions for the user: see chapter 9.
3.1 Builders opening and surround
The appliance can be installed in the following situations:
In a non-combustible fireplace or builders opening. This could be either
an existing builders opening or a new made prefab builders opening.
For the measurements, see figure 1 and index.
Although the appliance is tested for installation without a hearth, the
appliance must not stand on combustible materials or carpets. If the
appliance is placed on a combustible floor then a fibrelux or similar
heatproof board of 12 mm thickness should be placed under it. Any
under floor vents or openings within the builders opening should be
sealed off.
Do not place the lintel, surround or marble stone directly onto the
appliance. If possible, apply a lintel made of cement or something
similar.
Isolate the appliance with a ceramic blanket (25 mm). See also
chapter 4: Installation instructions.
Preferred choice for insulation is unbound insulation wool (at
1000 °C gives no smell).
4
5
Download from Www.Somanuals.com. All Manuals Search And Download.
UK/IRL
UK/IRL
3.1 Builders opening and surround (continuing)
If the builders' opening is constructed out of non-combustible
F
composition board (Fibrelux) and you install the appliance without a
mantel then:
G
K
2
- Ventilate the space above the appliance (min. 1000 mm ).
E
I
M
L
D
- Always fit the DC convection set.
B
C
J
H
- The plaster of the outside has to be resistant to a high
A
temperature. Use therefore the plaster materials especially made for
this, to prevent discoloring (min. 100 °C temperature resistant).
fig. 1
If the appliance is to be fitted against a wall with combustible
cladding, the cladding must be removed from the area covered by the
surround.
Builders opening (mm) Feeling
Silence
Whisper
Spectra
Nova
780
Cadra
Nova
680
Misty
A Opening width*
B Opening height*
C Opening depth*
Shelf dimensions
(combustible)
960
649
385
960
649
385
780
705
430
710
890
370
698
798
The minimum height from the top surface of the fire to the underside
of any shelf made from wood or other combustible materials is as
follows:
430
430
D Min. height shelf from
top frame
- For a shelf up to 150 mm deep – Minimum height = 350 mm
(fig. 1).
350
150
350
150
350
150
350
150
350
150
350
150
E Depth shelf max.
Dimensions (mm)
F Box width
- If the shelf depth is greater than 150 mm add 50 mm to the upper-
clearance height for every 25 mm increase in shelf depth.
880
366
636
1064
678
47
880
366
636
1064
678
20
750
397
714
815
720
16
750
375
715
794
703
30
650
375
815
694
803
30
698
338
879
740
905
144
G Box depth
H Box height
- Side clearance = Minimum distance from the side of the fire frame
to combustible material = 150 mm.
I
J
Frame width
Frame height
K Frame thickness
L Position flue
(behind
frame)255
255
257
111
235
235
196
140
M Position flue (from the
back side
box)111
140
140
142
*the points A until C applies a tolerance from:
– 0 mm and + 5 mm.
table 1
6
7
Download from Www.Somanuals.com. All Manuals Search And Download.
UK/IRL
UK/IRL
3.2 Flue requirements
Flue restrictor
The appliance is of the type C11/C31. The appliance will need to be
If applicable, in the table is also stated the size of a flue restrictor.
This restrictor needs to be fitted in the combustion chamber when
placing the appliance ( see chapter 4.2). Normally the smallest flue
restrictor is fitted.
supplied with the approved flue pipes and terminal, it is not possible to
supply your own.
The minimum effective height of the flue system must be 0.5 or 1 meter,
depending on the appliance.
Terminal locations, through the wall as well as through the roof. See
figure 3.
Flue routing;
- a horizontal extension with elbows is allowed for a maximum of
6 meters (depending on the type and situation).
- vertical max. 12 meters.
Determine on the base of the table 2 and 3, depending on the type
and terminal position, if the desired situation is possible.
To establish this you will need to calculate:
- The effective height (this is the real difference in height between the
upper side of the appliance and the terminal).
- The total horizontal extension. This is the total horizontal flue length
where:
• each elbow, which is in the horizontal area, counts for 2 meters.
• each 45-degree bend, which is in the horizontal area, counts for
1 meter.
• elbows and bends at the transition of horizontal to vertically are
not to be counted.
• the wall mounted terminal counts for 1 meter.
8
9
Download from Www.Somanuals.com. All Manuals Search And Download.
UK/IRL
UK/IRL
Example calculation 1
Table Silence and Feeling with interior Widescreen
Determine according to the table 2 the right total horizontal- and vertical length.
When meeting an X, and when the values are outside the table, the combination is
not allowed. Normally the 30 mm flue restrictor is preinstalled.
Calculati0n horizontal extension fig. 2a:
Flue lenght C + E = 1m + 1m
Elbows = 2m
2 m
2 m
D
Total horizontal extension
4 m
Horizontal extension
Measure or calculate effective height (Hvert)
0
1
2
3
4
5
6
0
1
1,5
2
3
4
5
6
7
8
Flue lenght A
1 m
1 m
X
0
0
X
0
0
X
X
0
X
X
0
X
X
X
0
X
X
X
0
0
0
30
30
30
X
X
X
X
X
X
X
X
0
0
0
0
0
X
X
X
X
X
X
Roof mounted terinal
G
F
X
combination
not allowed
Total effective height
2 m
30
45
45
50
50
60
60
65
65
65
65
30
45
45
50
50
60
60
65
65
65
0
0
When calculating on basis of the
Widescreen table nr. 2:
It is allowed.
0 remove flue restrictor
30
30
45
45
50
60
60
65
30
30
30
30
45
50
60
0
E
Number is size in mm
of the flue restrictor
30
30
30
45
50
C
B
Remove the flue restrictor!
D
When calculating on basis of the
MV100 table nr. 3:
Allowed but without flue restrictor.
Remove the flue restrictor!
A
9
X
When calculating on basis of the
MV150 table nr. 4:
Allowed but without flue restrictor.
Remove the flue restrictor!
10
11
12
X
X
X
X
X
X
X
X
table 2
interior Widescreen
X
When calculating on basis of the
Roundscreen table nr. 5:
Allowed but without flue restrictor.
Remove the flue restrictor!
Table Whisper and Spectra Nova with interior MV100
fig. 2a
Determine according to the table 3 the right total horizontal- and vertical length.
When meeting an X, and when the values are outside the table, the combination is
not allowed. Normally the 30 mm flue restrictor is preinstalled.
Example calculation 2
Calculati0n horizontal extension fig. 2b:
Flue lenght J + L = 0,5 + 0,5
1 m
4 m
1 m
Elbows
K + M = 2m + 2m
Horizontal extension
Terminal
0
X
1
X
0
2
X
0
0
30
30
45
45
60
60
60
65
3
X
0
0
0
4
X
0
0
0
5
X
0
0
0
0
0
0
45
X
X
X
X
X
6
Total horizontal extension
6 m
0
1
2
3
4
5
6
7
8
X
0/X*
0
0
0
0
0
30
30
45
45
50
50
60
60
65
65
65
65
X
0
combination
not allowed
remove flue restrictor
Vertical
30
45
45
50
50
60
60
65
65
65
X
M
Flue lenght
H
1 m
L
N
0
0
I
J
K
When calculating on basis of the
Widescreen table nr. 2:
Combination not allowed.
Number is size in mm
of the flue restrictor
45
45
50
60
60
X
X
X
30
30
50
50
X
X
X
X
X
X
X
X
X
X
When calculating on basis of the MV100
table nr. 3:
Allowed but without flue restrictor.
Remove the flue restrictor!
H
9
10
11
12
When calculating on basis of the MV150
table nr. 4:
Combination not allowed.
X
X
table 3
interior MV100
When calculating on basis of the
Roundscreen table nr. 5:
Combination not allowed.
* at propane not allowed
fig. 2b
10
11
Download from Www.Somanuals.com. All Manuals Search And Download.
UK/IRL
UK/IRL
Table Cadra Nova with interior MV150
3.2 Flue requirements (continuing)
3.2.1 Terminal position
Determine according to the table 4 the right total horizontal- and vertical length.
When meeting an X, and when the values are outside the table, the combination is not
allowed. Normally the 30 mm flue restrictor is preinstalled.
Verify if the required terminal position meets the local installation
regulations regarding disturbance, good functioning and ventilation.
(Also see: safety requirements).
Horizontal extension
0
X
X
1
X
0
2
X
X
0
3
X
X
0
0
4
X
X
0
0
0
0
30
40
40
5
X
X
0
0
6
Note:
0
0,5
1
2
3
4
5
6
7
8
9
10
11
12
X
X
X
0
0
0
0
0
X
X
X
X
X
X
The terminal must be located so that the outlet is not obstructed. If
the flue terminal is located within 2 meters of a footway, path or
where people could come into contact with it then a suitable
terminal guard must be fitted.
X
0
combination
not allowed
remove flue restrictor
30
30
40
40
50
50
50
60
60
60
65
X
40
40
50
50
50
60
60
60
65
65
65
0
30
40
40
50
50
50
60
60
X
X
0
0
0
30
40
40
40
50
Number is size in mm
of the flue restrictor
30
30
40
X
X
X
X
X
Terminals located close to shared walkways, footpaths etc. could be
subject to legal constraints and this should be pointed out to the
customer before installation. If in any doubt about flue location
advice should be sought from local building control, or if appliance-
related, from the manufacturer including wherever possible a
dimensioned sketch.
50
50
X
X
X
X
X
X
X
table 4
interior Cadra Nova
X
Misty with roundscreen
Avoid locating the terminal in close proximity to plastic materials
such as gutters or other combustibles. If this is unavoidable then a
suitable deflector should be made.
Determine according to the table 5 the right total horizontal- and vertical length.
When meeting an X, and when the values are outside the table, the combination is not
allowed. Normally the 30 mm flue restrictor is preinstalled.
Some important requirements for a good functioning are:
Horizontal extension
The wall-mounted terminal has to be at a distance of at least
0
1
2
3
4
X
X
0
0
0
0
0
30
40
40
50
5
X
X
X
0
0
6
0.5 meters off:
0
0,5
1
X
X
X
X
0
X
X
X
X
X
X
X
0
0
0
0
0
0
X
X
X
X
X
X
- Corners of the building.
X
0
combination
not allowed
remove flue restrictor
30
30
30
40
40
50
50
50
60
60
60
65
0
0
- Below eaves.
1,5
2
3
4
5
6
7
8
9
40
40
40
50
50
50
60
60
60
65
65
65
0
0
0
0
0
30
40
40
40
50
50
- Balcony's etc. unless the duct is dragged to the front side of the
overhanging part.
30
40
40
50
50
50
60
60
0
0
Number is size in mm
of the flue restrictor
30
30
40
X
X
X
X
X
The roof mounted terminal has to be at a distance of at least
0.5 meters of the sides of the roof, excluded the ridge.
X
10
11
12
X
X
X
X
X
X
table 5
interior Roundscreen
X
X
X
12
13
Download from Www.Somanuals.com. All Manuals Search And Download.
UK/IRL
UK/IRL
Flue terminal positions
Table 6
Dimension Terminal position
Balanced flue room sealed
(kW
input
7.5
kW
expressed
in
A
B
C
Direct below an opening, airbrick,
opening windows, etc.
Above an opening, airbrick,
opening window ect.
300 mm
300 mm
300 mm
Horizontally to an opening, airbrick,
opening window etc.
D
E
F
G
H
I
Below gutters, soil pipes or drain pipes
Below eaves
500 mm
500 mm
600 mm
300 mm
600 mm
300 mm
600 mm
600 mm
1200 mm
Below balconies or car port roof
From a vertical drain pipe or soil pipe
From an internal or external corner
Above ground roof or balcony level
From a surface facing the terminal
From a terminal facing the terminal
From an opening in the carport (e.g.
window) into the dwelling
J
K
L
M
N
P
Vertically from a terminal on the same wall
1500 mm
fig. 3
Horizontally from a terminal on the same wall 300 mm
From a vertical structure on the roof
Above intersection with roof
600 mm
500 mm
Q
14
15
Download from Www.Somanuals.com. All Manuals Search And Download.
UK/IRL
UK/IRL
Example of how terminal position is measured
4. INSTRUCTIONS FOR INSTALLATION
4.1 Gas connection
1. Installation pipes should be in accordance with BS 6891. Pipe work
from the meter to the appliance must be of adequate size.
2. The complete installation including the meter must be tested for
soundness and purged as described in the above code.
3. A means of isolation must be provide in the supply to facilitate
servicing.
4. The connection should be made in 8 mm copper or similar semi
flexible tube. (max 1 meter). Ensure that the gas pipe does not
interfere with the removal or replacement of the burner tray of the
controls.
5. The gas connection is nut and olive suitable for 8 mm pipe.
A
C
&
=
B
=
Behind surround
-
Sleeve pipe through surround
Through wall
-
Pipe must be sleeved and sealed to fire
C
fig. 4
outer wall
cavity
3.2.2 Using an existing chimney as air inlet
inner wall
You can connect the appliance onto an existing chimney. The existing
chimney then functions as air supply, where a flexible stainless steel
liner (to BS715) of 100 mm performs the flue function.
A
B
surround
marble
Requirements:
- Any existing chimney used as an air supply must only service this
appliance.
fig. 5
gas supply routes when fire is fitted in a deep surround
- A chimney that has previously been used for solid fuel must be swept
before use.
4.2 Preparing the appliances Widescreen and Whisper
- The existing chimney needs to be airtight.
- The existing chimney needs to have an opening of
min. 150 x 150 mm.
1. Open the ashtray door by pushing on the right side for the
Silence/Feeling and on the left side for the Whisper. Remove the
frame by loosening the screws A behind the door (see fig. 5).
Lift and pull forward when you take it away.
- The chimney needs to be intact and well looked after.
- Use the adjustable roof-mounted-terminal especially made for this,
and the chimney connection set.
- The minimum distance between two terminals should be at least
450 mm.
16
17
Download from Www.Somanuals.com. All Manuals Search And Download.
UK/IRL
UK/IRL
4.2 Preparing the appliances Widescreen and Whisper (continuing)
4.2 Preparing the appliances Widescreen and Whisper (continuing)
C
C
C
2.
C
C
C
C
C
C
C
A
fig. 8
A
A
fig. 6
4. Take the box with the log set out of the combustion chamber.
Remove the back panel by loosening the screws B (see fig. 6).
5. Place the right flue restrictor in the combustion chamber. To
determine the right flue restrictor, see chapter 3.
B
B
B
B
B
fig. 7
3. Remove the glass by removing the glass clamps C (see fig. 7) for
instance with a screwdriver. Careful when removing the glass! Wear
gloves! Before placing the glass back, be sure that there are no
fingerprints on the glass, it is not possible to remove those prints
after you burn the appliance or a while (they will be burnt in).
fig. 9
18
19
Download from Www.Somanuals.com. All Manuals Search And Download.
UK/IRL
UK/IRL
4.3 Preparing the appliance Misty
4.3 Preparing the appliance Misty (continuing)
4. Take the box with the log set out of the combustion chamber.
5. Place the right flue restrictor in the combustion chamber. To
determine the right flue restrictor, see chapter 3.
fig. 10
1. Remove the door frame. Lift and pull forward (see fig. 10).
2. Open the ashtray door by pulling down (bottom handle).
C
fig. 12
C
fig. 11
3. To open the door, remove the screws C (see fig. 11). The door
opening is limited; if you need more space then remove the door (lift
and pull forward). Be sure that there are no fingerprints on the glass.
It is not possible to remove those prints after you burn the appliance
for a while (they are burnt in).
20
21
Download from Www.Somanuals.com. All Manuals Search And Download.
UK/IRL
UK/IRL
4.4 Preparing the appliances Spectra Nova/Cadra Nova
4.4 Preparing the appliances Spectra Nova/Cadra Nova (continuing)
4. Take the box with the log set out of the combustion chamber.
5. Place the right flue restrictor in the combustion chamber. To
determine the right flue restrictor, see chapter 3.
fig. 13
1. To open the door, remove the screws A (see fig. 13). Open and
remove the door; lift and pull forward. Be sure that there are no
fingerprints on the glass. It is not possible to remove those prints
after you burn the appliance for a while (they are burnt in).
fig. 15
fig. 14
2. Remove the back panel by loosening the 4 screws B (see fig. 14).
22
23
Download from Www.Somanuals.com. All Manuals Search And Download.
UK/IRL
UK/IRL
4.5 Fitting the firebox
4.5 Fitting the firebox (continuing)
Points of attention for placement:
ceramic
blanket
ceramic
blanket
- If possible, first locate the appliance before assembling the flue.
- If this is not possible then always use an extendible pipe before
connection onto the appliance.
ceramic blanket
1. Position the firebox in the fireplace opening. You can adjust the
height with the 4 adjustable feet.
ceramic
blanket
ceramic
blanket
2
Make the gas connection according to the instructions (also see gas
connection, chapter 4.1).
3. Assemble the flue system onto the firebox (see chapter 5).
fig. 17
4. Check if applicable that the safety hatch seals the combustion
chamber properly.
8. Spread, the bags of embers (imitation ashes) provide with the
appliance over the burner tray.
Attention! No embers on the grid end between the logs and the
burner tray.
9. Before placing the glass; check the glass sealing rope is in good
condition and makes an effective seal. Be sure that there are no
fingerprints on the glass. It is not possible to remove those prints
after you burn the appliance for a while (they are burnt in).
safety hatch
- Widescreen and Whisper; Place the glass in front of the appliance
and fix it with the glass clamps. Replace the frame.
- Misty, Cadra Nova and Spectra Nova:
fig. 16
Place the door and fix it. Check on visual leakages around the
door sealing.
5. If necessary, place the DC convection system (also consult the
instruction belonging to the DC construction set).
10. Misty and widescreen: Fix the back and top or door frame (the back
frame first).
6. Isolate the firebox with a ceramic blanket (25 mm). Preferred choice
for insulation is unbound insulation wool (at 1000 °C gives no
smell).
7. Place the log set (see placing log set, chapter 4.4).
24
25
Download from Www.Somanuals.com. All Manuals Search And Download.
UK/IRL
UK/IRL
4.6 Placing the log set
5. INSTALLATION OF THE FLUE
Never place extra elements of any kind into the combustion chamber.
5.1 Connections with use of concentric duct material
To guarantee good combustion, the log set may only be installed in
the way specified by Faber International. Any other arrangement can
lead to soot on logs or window. Do not use the fire with broken or
missing logs.
- Build the system starting from the appliance on.
- Make a hole of ø 153 mm for the wall or roof mounted terminal.
4.6.1 Placing the log set Widescreen, Whisper, Spectra Nova, Misty and Cadra Nova
- Make sure you place the pipes in the right direction, the narrow
end towards the appliance.
- Make sure the pipes are fixed sufficiently, a wall clamp every 2m, so
the weight of the pipes is not resting onto the appliance.
- The outside of the pipe can become hot (140 degrees). Stay 50 mm
away from wall surface or sealing. Make sure to provide sufficiently
heat resistant isolation when going through the wall or roof.
fig. 18
- Because of expansion or cooling down the concentric pipes can turn
loose. It is recommended to fix the spring clip with a self tapping
screw at inaccessible places.
- To get the exact measure flue length you can use cut down-
concentric pipe, wall mounted terminal or roof mounted terminal. To
obtain a smoke sealed connection, the inner pipe must be 20 mm
longer then the outside pipe.
fig. 19
On the bottom of the logs is a identification:
- The horizontal pipes need to rise away from the appliance at a rate
of 3 degrees per metre.
• L
• R
location on the left side resting on the rear log.
location on the right side resting on the rear log.
• 1 dimple first log left placed over the burner and resting on the
burner tray.
• 2 dimples placed in the middle over he burner and resting on the
burner tray.
• 3 dimples the right side log placed over the burner and resting on the
burner tray.
Attention! Beware that there are no embers between the logs and the
burner tray.
26
27
Download from Www.Somanuals.com. All Manuals Search And Download.
UK/IRL
UK/IRL
5.2 Connection onto an existing chimney
5.2 Connection onto an existing chimney (continuing)
You can connect the appliance onto an existing chimney. The existing chimney then
functions as air supply, where a flexible stainless steel liner (to BS715) of 100 mm
performs the flue function. Any existing chimney used as an air supply must only
service this appliance.
5. Fixing the chimney sealing plate (D) and place the 150 mm
grommet into the hole of the sealing plate.
6. Fix the sealing plate air tight into the builders opening (use the
isolation rope from the chimney connection set to make the plate
air tight).
Requirements:
- 300 mm of free space above the appliance;
- The chimney only supply’s air to this appliance;
- The existing chimney needs to be clean and very well swept;
- The existing chimney needs to be airtight;
- The existing chimney needs to have an opening of
min. 150 x 150 mm.
7. Slide the pipe (E) 150mm length 500mm into the sealing plate.
Slide this pipe so far that you will have enough space later on
for assembling the liner.
8. Install the appliance.
Parts needed for this kind of installation:
- Chimney connection set
9. Connect the flexible stainless steel liner onto the appliance using
the 100mm pipe (F) as adapter.
part number A9225000
- Short roof terminal
Fig 20 part D
Fig 19 part B
Fig 19 part A
B
A
part number A9266100
- Chimney closure plate
part number A 9240000
10. If the distance from the flue outlet to the sealing plate is bigger
then 300 mm, you have to use a concentric pipe first.
C
- Two stainless steel tubes one 100 mm -
length 500 mm and one 150 mm -
length 500 mm
11. Slide the outside pipe onto the appliance or concentric extension
so that you have a air tight connection.
part number A 9273900
Fig 19 part E and F
1. Place the aluminium closure plate (A) onto the
chimney. Permanently attach and make airtight.
D
2. Pull the liner (C) through the chimney.
F
E
3. Connect the liner onto the roof terminal and fix
this with the clamp provided with the chimney
connection set.
4. Place the roof terminal onto the closure plate.
fig. 20
28
29
Download from Www.Somanuals.com. All Manuals Search And Download.
UK/IRL
UK/IRL
5.3 Remote control (if applicable)
The remote control is only meant to regulate the flames, it functions
only when the pilot burner is ignited. It is therefore not possible to
ignited the appliance with the remote control or to shut-off the pilot-
flame.
fig. 22
The radio-frequency remote control is intended for fireplaces installed
in a domestic setting in all EU countries except Austria, Denmark,
Finland and Greece.
3. Connect the wires to the gas valve (see fig. 22).
Features:
4. Check that there are batteries in the transmitter.
See "Replacing batteries", see chapter 10.4.4.
- Manual control will always remain possible.
- The remote control is a radio frequency type and has been approved
internationally.
5. Set the on/off switch on the receiver to "on".
- The remote control generates a unique safety code every time you
activate the transmitter, its similar to those used in a car.
- The remote control is easy to install retrospectively.
Setting the right transmission code
The receiver has to learn the code from the transmitter, which is already
done at the factory. However the code disappears if the receiver is
disconnected from the mains for a longer period.
5.3.1 Installation remote control
1. Connect the mains adapter to the receiver box. The adapter is set
to the correct voltage in the factory 4.5V.
1. Push the "mod" button on the receiver and hold it for 3 seconds.
2. The green control lamp will light up and stay on. Repeat this step
if it doesn't.
3. Push a button on the remote control. The control lamp on the
receiver should now go out.
4. Again push a button on the remote control. The lamp starts
flashing and will switch off eventually.
fig. 21
2. Slide the receiver box into the holder.
5. The receiver now recognizes the remote control. The remote
control now functions.
6. Check if you can hear a sound and the motor runs when you
push a button on the remote control.
30
31
Download from Www.Somanuals.com. All Manuals Search And Download.
UK/IRL
UK/IRL
6. COMMISSIONING (functional checks)
6.3 Functional balanced flue check
1. Set the appliance on max. input.
6.1. Check pilot ignition
2. Verify the flame picture, this means no flames against the
window, the flame have to come besides the logs, if not check
the log layout.
1. Push in and turn the control knob (A) from { anticlockwise to the
setting (small flame). You will hear a tick meaning there is
3. Check if the flames are yellow after 10 minutes of operation. If
you still have a blue flame or the appliance goes out check:
- If the flue pipes are fitted correctly (no leakage).
- If the wall mounted terminal is placed with the correct side up.
- If the correct flue restrictor is installed.
ignition. Hold the knob in and wait for a few seconds while the air
is purged.
2. Bring the knob back in the start position and turn the knob several
times to the
position. Check that the pilot has lit.
3. Continue to hold in the control knob for a further ten seconds to
ensure that the pilot flame is stable.
4. Release the knob. The pilot should remain alight.
A
B
D
C
C
A
B
B
A
fig. 24
6.4 Check reference pressure
The appliance is preset to give the correct heat input.
fig. 23
No further adjustment is necessary. Fit a pressure gauge at the test
point D to check the burner pressure.
6.2 Functional burner check
The pressure should be checked with the appliance alight and at max
1. Turn knob (B) to max. clockwise.
2. Turn the knob (A) more anticlockwise to the
input.
position (large
The setting pressure should be as shown at the technical data
page 41.
flame). Now it is possible to light the main burner.
3. Turn knob B anticlockwise to max. The main burner should light.
Check for gas soundness at all joints with leak detection floud!
4. Check the ignition of the main burner on low and high setting.
5. Turn knob B clockwise till {. The main burner is off.
6. Turn the knob A to {. The pilot should go out.
After checking the pressure, turn off the appliance. Remove the
pressure gauge and close the sealing screw. Re-light the appliance.
Turn to max. input and test around the test point D for gas
soundness using a suitable leak detection fluid.
32
33
Download from Www.Somanuals.com. All Manuals Search And Download.
UK/IRL
UK/IRL
7. HANDING OVER
8. SERVICING
(final check and customer briefing)
To ensure safe, efficient operation of the appliance, it is necessary to
carry out routine servicing at regular intervals.
7.1
Instruct the customer on the full operation of the appliance.
7.2.1 Advise the customer how to clean the appliance including the
It is recommended, that the fire is inspected/serviced by a competent
person at least once a year.
glass.
7.2.2 Instruct the customer on the operation of the remote control,
including replacement of batteries and how to set the right
transmissions code.
Important
Turn off the gas supply before commencing any servicing. Always
test for gas soundness after refitting the appliance.
7.2.3 Hand over these instructions including the user guide to the
consumer.
8.1 Routine annual servicing
7.2.4 Recommend that the appliance should be serviced by a
1. Clean (if necessary):
competent person at least once a year.
- the pilot system;
- the burner;
- the combustion chamber;
- the glass.
2. Check the log lay and replace the embers (if applicable).
3. Do the functional test as described at page 34.
4. Check the flue system and terminal on damage and soundness
(visual inspection).
34
35
Download from Www.Somanuals.com. All Manuals Search And Download.
UK/IRL
UK/IRL
8.1.1 Cleaning the glass
8.1.4 Burner tray assembly
Depending on the intensity of use, you can get a deposit on the
1. Remove the front, glass, log set, grid and burner tray cover.
2. Break the gas supply at the control valve.
3. Unscrew the burner assembly and take them out of the combustion
chamber.
glass. This can be removed with a special ceramic glass cleaner
(ceramic cook-top cleaner) as follows:
1. Remove the front and the back.
2. Clean the glass. Handle the glass with clean hands, wear gloves if
possible.
B
3. To fit the glass, proceed in reverse order. Make sure that the log
set has been installed correctly before fixing the glass.
A
D
C
Attention:
Before placing the glass: check the glass sealing rope is in good
condition and makes an effective seal. Be sure that there are no
fingerprints on the glass. It is not possible to remove those prints
after you burn the appliance for a while (they are burnt in). Place
the glass in front of the appliance and fix the glass frame or use the
glass clamps.
E
F
8.1.2 Cleaning the combustion chamber and burner
fig. 25
You can clean the combustion chamber with a vacuum cleaner.
A. Pilot assembly
B. Burner
If the burner is visibly damaged, this can affect the distribution of
the flame, if so then replace the burner.
C. Fixation plate
D. Injector
8.1.3 Propane conversion
E. Gas control
F. Receiver
For conversion from propane to natural gas, order for a propane
burner unit.
Please give the serial number from the data plate when you order.
8.1.5 Pilot/thermocouple assembly
Remove the burner tray as described above.
Now you have access to all the pilot and thermocouple parts.
36
37
Download from Www.Somanuals.com. All Manuals Search And Download.
UK/IRL
UK/IRL
8.1.7 Combustion test
8.1.6 Gas control block
A BS7967 combustion analysis check should be carried out using an
analyser to BS7927 positioned in the flue outlet.
A Ratio of CO/CO2 should be less than 0.01 within 30 minutes.
(100ppm CO per 1% CO2).
A reading of CO in the room centre should give a rise of less than
9ppm over ambient, peak reading.
A
B
A
B
D D
C
C
A
B
C
D
Governor
fig. 26
Adjusting screw pilot flame
Inlet pressure test point
Burner pressure test point
38
39
Download from Www.Somanuals.com. All Manuals Search And Download.
UK/IRL
UK/IRL
8.2 LIST OF SPARE PARTS
8.3 TECHNICAL DATA
Widescreen Silence en Feeling C11/C31
Country
UK/IRL
UK/IRL
II2H3+
Category
II2H3+
Whisper Feeling
Silence
Misty
Spectra Cadra
Nova Nova
Company Company Company Company Company Company
part part part part part part
Model type
C11 0f C31
C11 0f C31
Description
Heat input Hi
Efficiency class
NOX class
kW
7,5
2
7,2
2
Surround antracite
Glass
A9271453 A9270053 A9267753 AA9272853 A9274149 A9274249
04508200 04508300 04508300 04509000 4509500 04509300
04509600 04509400
4
4
Type of gas
Inlet pressure
G20
G30
30 / 37
mbar 20
Glass below
Burner NG
Burner propane
Log set
x
x
x
x
20521808 20521808 20521808 20521808 20521808 20900166
20521835 20521835 20521835 20521835 20521835 20900167
20773200 20774500 20772500 20786130 20773700 20773700
06017300 06017300 06017300 06017300 06017300 06017300
20604000 20604000 20604000 20604000 20604000 20604000
20603900 20603900 20603900 20603900 20603900 20603900
20900142 20900142 20900142 20900142 20900142 20900142
37003089 37003089 37003089 37003089 37003089 37003089
control)37003086 37003086 37003086 37003086 37003086 37003086
Gas rate 15 °C / 1013 mbar
m3/h 740
kg/h
231
540 g
Reference burner pressure
Injector size
mbar 17
22
Spark wire
Receiver
mm
mm
3x 1,45
3x 1,00
1,1
Remote control
Adapter
1x 1,30
1,8
Reduced input restrictor
Gas control
Pilot assembly
Type
Motor
(remote
SIT 160
Nr 51
SIT 160
Nr 30
Pilot burner assemb. NG 20900145 20900145 20900145 20900145 20900145 20900145
Pilot burner assemb.
Code
propane
20900154 20900154 20900154 20900154 20900154 20900154
37002033 37002033 37002033 37002033 37002033 37002033
06006600 06006600 06006600 06006600 06006600 06006600
20900019 20900019 20900019 20900019 20900019 20900019
Flue system
Thermocouple
Spark electrode
Embers
MV size
100-150
30
100-150
30
Preinstalled flue restrictor
mm
Gas control
GV36 with
GV36 without
pressure reg.
Heat resisting paint
pressure reg.
spray for comb. chamb. 09000008 09000008 09000008 09000008 09000008 09000008
Set of glass clips
20900008 20900008 20900008
28103900 28103900 28103900
x
x
x
x
x
x
Remote control
Adapter
V
4,5
Touch Latch assembly
Batteries remote control
2x LR03 1,5 V Alkaline
Gas connection
mm
8 mm nut
and olive.
18 mm nut
and olive
Dimensions: see table 1
40
41
Download from Www.Somanuals.com. All Manuals Search And Download.
UK/IRL
UK/IRL
8.3 TECHNICAL DATA
8.3 TECHNICAL DATA
MV100 Whisper and Spectra Nova
MV150 Cadra Nova
Country
UK/IRL
II2H3+
UK/IRL
II2H3+
Country
UK/IRL
II2H3+
UK/IRL
II2H3+
Category
Category
Model type
C11 0f C31
C11 0f C31
Model type
C11 0f C31
C11 0f C31
Heat input Hi
Efficiency class
NOX class
kW
7.5
2
7.5
2
Heat input Hi
Efficiency class
NOX class
kW
7,5
2
7,5
2
4
4
4
4
Type of gas
Inlet pressure
G20
20
G30
30/37
Type of gas
Inlet pressure
G20
20
G30
30/37
mbar
mbar
Gas rate 15 °C / 1013 mbar
m3/h
kg/h
800
231
Gas rate 15 °C / 1013 mba
m3/h
kg/h
790
17
231
540 g
540 g
Reference burner pressure
Injector size
mbar
mm
13
25
Reference burner pressure
Injector size
mbar
mm
22
3x 1.50
1.8
3x 0.90
1.1
2x 1,40
1x 1,30
1,8
3x 1,00
1,1
Reduced input restrictor
mm
Reduced input restrictor
mm
Pilot assembly
Type
Pilot assembly
Type
SIT 160
Nr 51
SIT 160
Nr 30
SIT 160
Nr 51
SIT 160
Nr 30
Code
Code
Flue system
Flue system
MV size
100-150
30
100-150
30
MV size
100-150
30
100-150
30
Preinstalled flue restrictor
mm
Preinstalled flue restrictor
mm
Gas control
GV36 with
GV36 without
Gas control
GV36 with
GV36 without
pressure reg. pressure reg
pressure reg. pressure reg.
Remote control
Voltage adapter
Batteries
V
4,5
Remote control
Voltage adapter
Batteries
2x LR03 1,5 V Alkaline
V
4,5
2x LR03 1,5 V Alkaline
Gas connection
mm
kg
8 mm nut
and olive
8 mm nut
and olive
Gas connection
mm
kg
8 mm nut
and olive
8 mm nut
and olive
Weight incl. packing material
Dimensions: see table 1
75
75
Weight incl packing material
Dimensions: see table 1
75
75
42
43
Download from Www.Somanuals.com. All Manuals Search And Download.
UK/IRL
UK/IRL
8.3 TECHNICAL DATA
Roundscreen Misty
Country
UK/IRL
II2H3+
UK/IRL
II2H3+
Category
Model type
C11 0f C31
C11 0f C31
Heat input Hi
Efficiency class
NOX class
kW
8,5
2
8,5
2
4
4
Type of gas
Inlet pressure
G20
20
G30
30 / 37
USER GUIDE
mbar
Gas rate 15 °C / 1013 mbar
m3/h
kg/h
900
231
540 g
Reference burner pressure
Injector size
mbar
mm
16
25
3x 1,50
1,8
3x 0,95
1,1
Reduced input restrictor
mm
Pilot assembly
Type
SIT 160
Nr 51
SIT 160
Nr 30
Code
Flue system
MV size
100-150
30
100-150
30
Preinstalled flue restrictor
mm
Gas control
GV36 with
GV36 without
pressure reg. pressure reg.
Remote control
Voltage adapter
Batteries
V
4,5
2x LR03 1,5 V Alkaline
Gas connection
mm
8 mm nut
and olive
8 mm nut
and olive
Dimensions: see table 1
44
45
Download from Www.Somanuals.com. All Manuals Search And Download.
UK/IRL
UK/IRL
9. SAFETY INSTRUCTIONS FOR THE
USER
IMPORTANT
A suitable Fireguard conforming to BS6539 and BS6778 should be used
with this appliance to protect children, the elderly or infirm. Care
should also be taken with pets.
9.1 General safety instructions
In your own interest and that of safety, all gas appliances must be
installed by competent persons. Installation must be in accordance with
National Regulations. CORGI registered installers are required to work to
recognised standards.
If a gas leak is found or suspected, turn off the gas supply at the
meter and contact your installer or gas emergency service.
These instructions should be read carefully and retained for future
reference.
Note:
Since the appliance is a source of heat, circulation of air occurs.
Therefore it is of importance that you do not use the appliance shortly
after a renovation of the home. Because of the natural circulation of air,
moist and volatile components from paint, building materials, carpet etc.
will be attracted. These components can settle themselves down onto
cold surfaces in the form of soot. As on all heat producing appliances,
soft furnishings such as blown vinyl wallpaper placed too near to the
appliance may become scorched or discoloured. This should be born in
mind when installing the appliance.
Do not use the fire with a broken or damaged glass.
The fire has a safety device which turns off the gas supply if there is a
build up from flue gasses in the combustion room or a temporary gas
cut-off. Wait at least 5 minutes before turning the appliance on again.
Contact a qualified installer when the appliance goes off regularly.
The appliance has been designed for heating purposes. This means that
all surfaces, including the glass, can become very warm (over
100 degrees). An exception to this is the lower side of the door and the
control buttons.
Due to the newness of materials, they may give off a slight smell for a
period after initial lighting. This is normal, odours will disperse after a
few hours use.
Do not place curtains, clothing, laundry, furniture or other flammable
materials nearby the appliance. The required minimum distance is
100 cm.
Switch off the receiver of the remote control if you don’t use the fire for
a long time. Do not let children use the remote control without
supervision.
46
47
Download from Www.Somanuals.com. All Manuals Search And Download.
UK/IRL
UK/IRL
10. CONTROLLING THE APPLIANCE
Knob A
The { is the OFF position preventing any gas from passing through the
control valve to either the pilot burner or to the main burner. By pressing
the knob in it is possible to turn it anticlockwise. The first function is to
turn on the gas to the pilot- this occurs just before reaching the
|position (if the fire has not been lit for some time it may be necessary
to hold the knob in this position for some seconds to clear the air from
the pipe and allow gas to reach the pilot burner). Once gas is available
at the pilot, continued rotation anti-clockwise will cause the piezo igniter
to spark. This is accompanied by a click at the valve and should result in
the pilot burner igniting. Once the pilot is lit, the control knob should be
held pressed in for 10 seconds. In this time the pilot flame will have
heated the flame supervision thermocouple sufficiently to operate a hold-
on magnet within the valve. Now turn the control knob A to the
position. This allows gas to enter control knob B.
10.1 Lighting the fire
If the main burner or pilot light are extinguished for any reason, do
not attempt to relight the pilot within 5 minutes. Contact a qualified
installer when the appliance goes off regularly.
The control valve is behind the ashtray door.
Silence /Feeling /Whisper
Open the ashtray door by pushing on the right side for the
Silence/Feeling and on the left side for the Whisper.
Misty
Open the ashtray door by pulling down (bottom handle with gas
damper).
Knob B
The { is the OFF position preventing gas entering the main burner if
the pilot is lit. The knob should be turned slowly anticlockwise. This
allows gas to enter the burner and be ignited by the pilot flame. Once
ignition has taken place, the fire may be set to any level between min.
and max. by adjusting the control knob B.
Cadra Nova and Spectra Nova
Open by pushing the lip located on the right side in the gap between
the ashtray door and the frame (door flaps open).
A
B
10.2 To light
1. Push in and turn the control knob (A) from { anticlockwise to
the setting
(small flame). You will hear a ignition click. Check
that the pilot is lit (if not repeat).
2. Continue to hold in the control knob for a further ten seconds to
ensure that the pilot flame is stable.
3. Release the knob. The pilot should remain alight.
fig. 27 control unit
4. Turn the control knob A to the
position.
With control button A you can light the pilot. With the control button
B you can adjust the height of the flames (see fig. 27).
5. Turn knob B slowly anticlockwise, the fire should then ignite.
6. Adjust flames to the required level.
48
49
Download from Www.Somanuals.com. All Manuals Search And Download.
UK/IRL
UK/IRL
10.3 To extinguish
10.4.1 To light
1. Push in and turn the control knob (A) from { anticlockwise to
1. For the main burner turn the control knob B clockwise to
the setting (small flame). You will hear a ignition click. Check
that the pilot is lit (if not repeat).
position {.
2. To disable knob B turn knob A to the
position.
2. Continue to hold in the control knob for a further ten seconds to
ensure that the pilot flame is stable.
3. To extinguish the pilot turn control knob A to position { ,
although it is in order lo leave the pilot permanently lit.
3. Release the knob. The pilot should remain alight.
10.3.1 When the pilot extinguishes
Warning! When the pilot extinguishes, for whatever reason, you should
4. Turn the control knob A to the
position.
wait at least 5 minutes before trying to turn it on again.
5. Set the on/off switch on the receiver to "on”.
Possible causes of pilot extinguish are:
- Operating error.
low flame
high flame
- Interference of the safety device.
- Failure in the pilot flame system.
6. Use
(high) and
(low) to achieve the desired heating and
Contact a qualified installer when the appliance goes off regularly.
flame effect.
fig. 28
remote control 7. You will hear a beep every time the receiver recognises a good
signal. (If not, so see 10.4.3, setting the right transmission code).
10.4 Remote control version
The remote control is only meant to regulate the flames from off till
max., it functions only when the pilot burner is ignited and knob A in
(big flame) position. It is therefore not possible to ignite the pilot
flame with the remote control or to extinguish the pilot flame. The
radio-frequency remote control is intended for fireplaces installed in a
domestic setting in all EU countries except Austria, Denmark, Finland,
and Greece.
8. When the fire is not be used for a prolonged period, turn off the
pilot (see 10.4.2).
10.4.2 To extinguish
1. Push
clicking.
(low) till the burner goes out and you can hear the motor
2. To enable the remote control turn knob A to the
position.
Features:
- Manual control will always remain possible.
- The remote control is a radio frequency type and had been approved
internationally.
3. To extinguish the pilot turn control knob A to position {, although
it is in order to leave the pilot permanently lit.
- The remote control generates a unique safety code every time you
activate the transmitter, its similar to those used in a car.
- The remote control is easy to install retrospectively.
50
51
Download from Www.Somanuals.com. All Manuals Search And Download.
UK/IRL
UK/IRL
10.4.3 Setting the right transmission code
10.4.4 Changing the batteries
he receiver has to learn the code from the transmitter, which is already
There is no risk of electric shock as the low voltage supply is similar
to that used in torches. Always turn off the appliance before changing
batteries.
done at the factory. However the code disappears if the receiver is
disconnected from the mains for a longer period,
1. Set the on/off switch on the receiver to "on".
Remote control
2. Push the "mod" button on the receiver and hold it for 3 seconds.
1. Remove the cover on the back of the remote control.
3. The green control lamp will light up and stay on. Repeat this step
if it doesn't.
2. Carefully remove the battery clip along the side. Pay attention not
to pull the wires.
4. Push a button on the remote control. The control lamp on the
receiver should now go out.
3. If necessary, remove the old batteries and place the new ones:
2 x LR03 Alkaline long life 1.5 V.
+
5. Again push a button on the remote control. The lamp starts
flashing and will switch off eventually.
4. Click the battery clip into the remote control and close the cover.
5. It might be possible that you have to set the transmission code
after changing the batteries (see 10.4.3).
6. The receiver now recognizes the remote control. The remote
control now functions.
+
Note
7. Check if you can hear a sound and the motor runs when you
push a button on the remote control.
Batteries are chemical waste and should be disposed in accordance
with local regulations.
fig. 29
changing batteries
52
53
Download from Www.Somanuals.com. All Manuals Search And Download.
UK/IRL
UK/IRL
12. DISPOSAL OF THE PACKAGING
11. CLEANING AND SERVICE
INSTRUCTIONS
AND THE APPLIANCE
The appliance packaging is recyclable. The packaging could include
Important:
the following materials:
- cardboard;
Turn off the fire and allow it to cool down before
commencing cleaning.
- CFC-free foam (soft);
- wood;
It is recommended that the fire is inspected/serviced, by a competent
person at least once a year.
- plastic;
- paper.
To maintain the finish on the trim wipe with soft damp cloth only. Do
not use abrasive cleaners, polish or solvents as these can damage
the surface finish.
These materials should be disposed responsibly and in conformity
with government regulations.
Batteries are considered chemical waste. The batteries should be
disposed of responsibly and in conformity with government
regulations. Remove the batteries before disposing of the remote
control.
Information on how to responsibly dispose of discarded appliances
can be obtained from the local authorities.