Specifications — RG59-3MHR-3 Cable
UL NEC/
C(UL) CEC
UL AWM
Temp.
Standard
Lengths Weights
Shipping Conductor
Nominal
Core OD
Shielding
Materials
(% coverage)
Nom. DCR
Nominal
OD
Nominal
Capacitance
Nominal
Attenuation
Description
Nom.
Vel.
of
No.
of
Cond.
Nom.
Imp.
(ohms)
(stranding)
Diameter
Nom. DCR
Part No. (length)
Model
dB/
dB/
MHz
Prop.
Ft.
m
Lbs. kg
Inch mm
Inch mm
pF/ft pF/m
100 ft 100 m
(3) 20 AWG Coax + (3) 26 AWG Miniature Coax • Aluminum Foil (100%) + Tinned Copper Braid Shield
Nonplenum Cable • Gas-injected Foamed Polyolefin Insulation • PVC Inner Jackets • Gray PVC Outer Jacket
1
5
10
20
50
-0.3
-0.6
-1.0
-1.2
-1.3
-2.2
-2.5
-3.2
-3.3
-3.5
-4.5
-5.4
-7.3
-9.4
-19.4
-1.0
-2.0
-3.3
-3.9
-4.2
20 AWG
(solid)
0.032"
Alum. Foil
(100%)
3
coax
0.147 3.73
75
83%
17.3
56.8
500 152.4 112 50.8
Single:
0.236 5.99
red, green, blue
22-124-02 (500')
RG59-3MHR-3
Tinned Cu
Braid (95%)
0.81 mm,
Solid Cu
3 ohms/
1k ft,
9.8 ohms/
1 km
71
-7.2
-8.3
100
135
180
200
270
400
750
1000
3000
10.3 ohms/
1k ft,
34 ohms
1 km
-10.5
-10.8
-11.4
-14.8
-17.5
-23.9
-30.8
-56.9
Sweep tested 5 MHz to 1 GHz.
75 83% 18 59
NEC CM
UL 1581
CSA FT4
26 AWG
(7/34)
0.019"
1
5
10
20
50
-0.5
-1.2
-1.7
-2.4
-3.8
-4.5
-5.4
-6.3
-7.3
-7.7
-9.1
-11.5
-16.4
-19.5
-43.6
-1.7
-3.9
-5.5
3
coax
Alum. Foil
(100%)
0.076 1.93
Single:
0.107 2.72
black, yellow, white
Tinned Cu
Braid (95%)
-7.8
0.48 mm,
-12.3
-14.8
-17.6
-20.6
-23.9
-25.4
-29.9
-37.3
-53.8
-64.0
-143.0
75 °C
Tinned Cu
12.2 ohms/
1k ft,
40.0 ohms/
1 km
71
41 ohms/
1k ft,
135 ohms
1 km
100
135
180
200
270
400
750
1000
3000
Min. bend radius: 6.5"
Sweep tested 5 MHz to 1 GHz.
Overall:
0.625 15.9
gray
24 November, 2008
Download from Www.Somanuals.com. All Manuals Search And Download.
|