Elation Professional Work Light 12 Brick II User Manual

Design LED 12 Brick II  
Elation Professional™  
6122 S. Eastern Ave.  
Los Angeles, CA. 90040  
Rev. 03/08/08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design LED 12 Brick II ™  
1. GENERAL INFORMATION  
INTRODUCTION: Congratulations, you have just purchased one of the most innovative and  
reliable LED fixtures on the market today! The Design LED 12 Brick II ™, has been designed  
to perform reliably for years when the guidelines in this booklet are followed. Please read  
and understand the instructions in this manual carefully and thoroughly before attempting to  
operate this unit. These instructions contain important information regarding safety during  
use and maintenance.  
UNPACKING: Thank you for purchasing the Design LED 12 Brick II ™ by Elation  
Professional®. Every Design LED 12 Brick II ™ has been thoroughly tested and has been  
shipped in perfect operating condition. Carefully check the shipping carton for damage that  
may have occurred during shipping. If the carton appears to be damaged, carefully inspect  
your fixture for damage and be sure all accessories necessary to operate the fixture have  
arrived intact. In the event damage has been found or parts are missing, please contact our  
customer support team for further instructions. Please do not return this unit to your dealer  
without first contacting customer support at the number listed below.  
Inside the box you should find: the fixture, a DMX XLR cable, an IEC power cable, an IEC  
“jumper” power cable, a safety cable, and this manual. Please contact customer support at  
the number listed below if any of the above items are missing.  
CUSTOMER SUPPORT: Elation Professional® provides a customer support line, to provide  
set up help and to answer any question should you encounter problems during your set up  
comments or suggestions. For service related issue please contact Elation Professional®.  
Service Hours are Monday through Friday 9:00 a.m. to 5:00 p.m. Pacific Standard Time.  
Voice: (323) 582-3322  
Fax: (323) 582-3108  
Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to  
©Elation Professional, Los Angeles Ca.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design LED 12 Brick II ™  
rain or moisture.  
Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs  
yourself. Doing so will void your manufactures warranty.  
Please do not discard the shipping carton in the trash. Please recycle whenever possible.  
WARRANTY REGISTRATION: The Design LED 12 Brick II ™ carries a two year (730 days)  
limited warranty. Please fill out the enclosed warranty card to validate your purchase. All  
returned service items whether under warranty or not, must be freight pre-paid and  
accompany a return authorization (R.A.) number. The R.A. number must be clearly written  
on the outside of the return package. A brief description of the problem as well as the R.A.  
number must also be written down on a piece of paper and included in the shipping  
container. If the unit is under warranty, you must provide a copy of your proof of purchase  
invoice. Items returned without a R.A. number clearly marked on the outside of the package  
will be refused and returned at customer’s expense. You may obtain a R.A. number by  
contacting customer support at (323) 582-3322.  
©Elation Professional, Los Angeles Ca.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design LED 12 Brick II ™  
2. SAFETY INSTRUCTIONS  
To guarantee proper and consistent operation, it is important to  
follow the guidelines in this manual. Elation Professional will not  
accept responsibility for damages resulting from the misuse of  
this fixture due to the disregard of the information printed in this  
manual.  
1. Always be sure that the fan and the air inlets remain clean and are never  
blocked. Allow about 6” (15cm) between this fixture and other devices or a wall  
to allow for proper cooling.  
2. Never touch the fixture during normal operation.  
3. Never look directly into the lamp beam. You risk injury to your retina, which may  
induce blindness.  
4. For safe operation, follow the Installation guide described in chapter two of this  
manual. Operating the Design LED 12 Brick II ™ without suited safety aids such  
as safety cables or clamps can increase the risk of damage and/or personal  
injury.  
5. Installation should only be performed by qualified and certified personal.  
6. When mounting this fixture, use only the original rigging points included with this  
fixture. Any structural modification will void the original manufactures warranty  
and may increase the risk of damage and/or personal injury.  
7. To reduce the risk of fire or shock, do not expose this fixture to rain or moisture.  
8. Do not attempt to operate this fixture if the power cord has become damaged or  
frayed.  
9. Never open this fixture while in use.  
10.This device falls under protection-class I. Therefore it is essential that the device  
be grounded properly.  
11.All electrical connections must performed by qualified personal.  
12.Be sure the available voltage matches the voltage requirements of the unit. Be  
©Elation Professional, Los Angeles Ca.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design LED 12 Brick II ™  
sure the power cord is never crimped or damaged. If the power cord is damaged,  
replace it immediately with a new one of similar power rating.  
13.Always disconnect from main power before performing any type of service or  
any cleaning procedure.  
14.Only handle the power cord by the plug. Never pull out the plug by tugging the  
wire portion of the cord.  
15.Please be aware that damages caused by modifications to the device are  
not subject to warranty.  
Important Notice: Damages resulting from the disregard of safety and general user  
instructions found in this user manual are not subject to any warranty claims.  
Never touch the device during operation!  
The housing may heat up  
Never look directly into the light source,  
as sensitive persons may suffer an epileptic shock.  
©Elation Professional, Los Angeles Ca.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design LED 12 Brick II ™  
3. FEATURES  
Low power consumption  
Minimal heat emission  
Maintenance free operation  
Equipped with 12 one-watt LEDS: (4 red, 4 green, 4 blue)  
High power LEDS manufactured by Lumileds, USA  
100,000 hours rated LED life  
Seamless RGB color changing  
USITT DMX-512 complaint  
5-pin and 3-pin Male and Female XLR Data Connectors  
Preprogrammed colored macros  
Strobe-effect with a maximum flash rate of 18fps  
DMX-controlled operation or stand-alone operation with Master/Slave-function  
8 built-in programs accessed via DMX-controller or manually  
Sound-controlled via built-in microphone  
Individual control over each LED  
Electronic/Switching power supply (100v~240V 50/60Hz)  
Three DMX Modes:  
15 DMX-channels  
12 DMX-channels  
4 DMX-channels  
3 DMX-channels  
Flicker-free operation for television and film  
Compact design: fits in 12” box truss  
Brilliant light output  
Linkable power supply (in and out power connectors) up to 8 units.  
©Elation Professional, Los Angeles Ca.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design LED 12 Brick II ™  
4. GENERAL GUIDELINES  
This fixture is a professional lighting effect designed for use on stage, in nightclubs, in  
theatres, and other types of architectural installations. Do not attempt operation or  
installation without a proper knowledge on how to do so.  
This fixture was designed for indoor use only; use of this fixture outside will void the  
manufacture’s warranty.  
Consistent operational breaks will ensure that the fixture will function properly for many  
years to come.  
Do not shake the fixture around. Avoid brute force when installing or operating the fixture.  
While choosing an installation location, please be sure that the fixture will not be exposed to  
extreme heat, moisture, or dust. The minimum distance between the fixture and a wall or flat  
surface should be at least .5 meter (about 1.5ft).  
Always install the fixture with an appropriately rated safety cable. When installing the fixture  
in a suspended environment always be sure to use mounting hardware no less than M10 x  
25 mm, also be sure the hardware is only inserted in the yoke’s mounting holes.  
Do not attempt to operate this fixture until you have familiarized yourself with all of its  
functions.  
Do not permit operation by persons not qualified for operating this type of theatrical fixture.  
Most damages are the result of improper operation.  
Please use the original packaging to transport the fixture in for service.  
For your own safety, please read this user manual carefully before installing the device.  
©Elation Professional, Los Angeles Ca.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design LED 12 Brick II ™  
5. FIXTURE OVERVIEW  
3
2
1
8
9
5
7
6
4
10  
11  
14  
12  
13  
1. Bracket Locking Knob – This knob is used to secure the bracket in place after  
angle adjustments have been made.  
2. Diffusing Lens – This lens is used to both protect the LEDS as well as diffuse the  
light output.  
3. LED Assembly – RGB LED assembly 3x1watt LEDS  
©Elation Professional, Los Angeles Ca.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design LED 12 Brick II ™  
4. On/Off Power Switch – Controls main power to the unit.  
5. Power Output Jack – Use this jack to jump power to another Design LED 12 Brick II  
6. Power Input/Fuse Holder Assembly – This assembly holds the safety fuse as well  
as provides a female IEC connector for a power cord. Always replace the fuse with  
an exact match unless otherwise specified by an authorized Elation Service  
Technician. Using a fuse other than that specified could seriously damage the unit  
and will void your manufactures warranty.  
7. Eye-Bolt - Use this bold as a safety-cable rigging point. Always secure any installation  
with a properly rated safety-cable.  
8. LED MENU DISPLAY – Four segment LED menu display, details all menu functions  
9. DMX In Jack – This jack accepts an incoming DMX signal via a male, 3-pin or a 5-pin  
XLR jack.  
10.DMX Out Jack - This jack is used to send an incoming DMX signal to the next fixture  
in the DMX chain via a female, 5-pin XLR jack.  
11.ESC BUTTON – This button is used to access and exit the fixture’s on-board menu  
system.  
12.UP BUTTON – This button is used to scroll forward when navigating through the  
fixture’s menu system.  
13.DOWN BUTTON – This button is used to scroll backwards when navigating through  
the fixture’s menu system.  
©Elation Professional, Los Angeles Ca.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design LED 12 Brick II ™  
14.ENTER BUTTON This button is used to select and confirm a menu function.  
©Elation Professional, Los Angeles Ca.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design LED 12 Brick II ™  
6. MOUNTING AND INSTALLATION  
Yoke Assembly – Single Unit Operation (DLED 12 Brick shown for illustration purposes only).  
The device can be placed directly on the stage floor or rigged in any orientation on a truss  
without altering its operation characteristics. When connecting the hanging yoke to the  
fixture, refer to the illustration below.  
Cautions:  
For added protection mount the fixtures in areas outside walking paths, seating areas, and  
away from areas were the fixture might be reached by unauthorized personal.  
Before mounting the fixture to any surface, make sure that the installation area can hold a  
minimum point load of 10 times the device’s weight.  
Fixture installation must always be secured with a secondary safety attachment, such as an  
appropriate safety cable.  
To avoid injury, never stand directly below the device when mounting, removing, or servicing  
the fixture.  
Refer to regulations BGV C1 (formerly VBG 70) and DIN VDE0711-217  
for proper installation in Europe To ensure proper installation, only  
qualified staff should attempt installation.  
Mounting points  
©Elation Professional, Los Angeles Ca.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design LED 12 Brick II ™  
Overhead mounting requires extensive experience, including amongst others calculating  
working load limits, a fine knowledge of the installation material being used, and periodic  
safety inspection of all installation material and the fixture. If you lack these qualifications, do  
not attempt the installation yourself. Improper installation can result in bodily injury.  
Be sure to complete all rigging and installation procedures before connecting the main  
power cord to the appropriate wall outlet.  
Mounting  
The Design LED 12 Brick II ™ is fully operational in three different mounting positions,  
hanging upside-down from a ceiling, side mounted, or set on a flat level surface. Be sure this  
fixture is kept at least 0.5m away from any flammable materials (decoration etc.). When  
clamp mounting; always use and install the supplied safety cable as an added safety  
measure to prevent accidental damage in the event of a clamp failure. See the image  
below.  
©Elation Professional, Los Angeles Ca.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design LED 12 Brick II ™  
CAUTION!  
Be sure all electrical connections are performed by a qualified  
electrician before attempting any operation.  
Clamp Mounting  
The Design LED 12 Brick II ™ provides a unique mounting bracket assembly that allows the  
unit to stand on flat surface, hang on truss via a clamp, or be used in cluster allow multiple  
units to rigged together (see the illustration below). Regardless of the mounting option you  
choose please refer to the safety guidelines in this manual to avoid damage to the unit  
and/or injury to persons.  
When mounting this fixture to truss be sure to secure an appropriately rated clamp to the  
hanging yoke using a M10 screw fitted through the center hole of the hanging yoke. As an  
added safety measure be sure to attach at least one properly rated safety cable to the fixture.  
See illustration below.  
©Elation Professional, Los Angeles Ca.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design LED 12 Brick II ™  
Securing the Design LED 12 Brick II ™  
Always secure your fixture with a safety cable when  
suspend-ing the unit from truss or other means. The fixture  
provides a built-in rigging point for a safety cable as illustrated  
above. Be sure to only use the designated rigging point for a  
safety cable. Never secure a safety cable to the hanging  
bracket.  
©Elation Professional, Los Angeles Ca.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design LED 12 Brick II ™  
7. UNDERSTANDING DMX  
Data Cable (DMX Cable) Requirements (For DMX and Master/Slave Operation):  
Your fixture and your DMX controller require a standard 3-pin XLR connector for data input  
and data output (see figure below). Be sure to only use properly rated DMX cables for DMX  
operation and not standrd audio cables. If you are constructing your own cables be sure to  
use two conductor shielded digital cable rated at a 120 ohms (this cable can be purchased at  
almost all professional sound and lighting stores). Your cables should be made with a male  
and female 3-pin XLR connector on either end of the cable.  
Please note: This is not the same as audio microphone cable. Audio cable has a  
different resistance rating  
Be sure to follow the above figure when making your own cables. Do not use the ground lug  
on the XLR connector. Do not connect the cable’s shield conductor to the ground lug or  
allow the shield conductor to come in contact with the XLR’s outer casing. Grounding the  
shield could cause a short circuit and erratic behavior.  
DMX-512 control connection  
Connect the provided DMX XLR cable to the female 3-pin XLR output of your controller and  
the other side to the male 3-pin XLR input of the moving head (Please refer to the diagram  
below.). You can chain multiple moving heads together through serial linking. The cable  
needed should be two conductor, shielded cable with XLR input and output connectors.  
Always be sure daisy chain your in and out data connections, never split or “Y” your DMX  
connections unless you are using an approved DMX splitter such as the Elation Opto Branch  
©Elation Professional, Los Angeles Ca.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design LED 12 Brick II ™  
4™ or DMX Branch/4™.  
CONTROLLER  
Please note: to ensure maximal stability, only two devices may be connected together in  
this manner! From the third devices, please connect to power supply to get power for the  
second link.  
DMX-512 connection with DMX terminator  
When longer runs of cable are used, you may need to use a terminator on the last fixture to  
avoid erratic behavior. A terminator is a 120 ohm 1/4 watt resistor that is connected between  
pins 2 and 3 of a male XLR connector (DATA + and DATA -). This fixture is inserted in the  
female XLR connector of the last fixture in your daisy chain to terminate the line. Using a  
cable terminator (Elation part number Z-DMX/T) will decrease the possibilities of erratic  
behavior.  
©Elation Professional, Los Angeles Ca.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design LED 12 Brick II ™  
5-Pin XLR DMX Connectors. Some manufactures use 5-pin XLR connectors for DATA  
transmission in place of 3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX  
line. When inserting standard 5-pin XLR connectors in to a 3-pin line a cable adaptor must  
be used, these adaptors are readily available at most electric stores. The chart on the next  
page details a proper cable conversion.  
Understanding Fixture DMX addressing;  
All fixtures should be given a DMX starting address when using a DMX controller, so the  
correct fixture responds to the correct control signal. This digital starting address is the  
channel number from which the fixture starts to “listen” to the digital control information sent  
out from the DMX controller. The allocation of this starting DMX address is achieved by  
setting the correct DMX address on the digital display located on the head of the fixture.  
You can set the same starting address for all fixtures, or a group of fixtures, or set different  
address for each individual fixture. Be advised that setting all you fixtures to the same DMX  
address will subsequently control all fixtures in the same fashion, in other words, changing  
the settings of one channel will affect all the fixtures simultaneously.  
If you set each fixture to a different DMX address, each unit will start to “listen” to the channel  
number you have set, based on the quantity of control channels (DMX channels) of each  
fixture. That means changing the settings of one channel will only affect the selected fixture.  
In the case of the Design LED 12 Brick II ™, which is a 3 channel fixture (default), you should  
set the starting DMX address of the first unit to 1, the second unit to 4 (3 + 1), the third unit to  
7 (4 + 3), and so on. The chart on page 20 details the proper starting DMX address dipswitch  
setting combination.  
©Elation Professional, Los Angeles Ca.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design LED 12 Brick II ™  
8. OPERATING MODES  
This fixture can run in three different DMX modes, the following pages will detail the different  
operating modes as well as how to achieve the different operating modes.  
DMX Settings: The chart below describes how to access the different DMX modes. The  
chart below also defines the how the channel will function in the different DMX modes.  
1DMX Mode:  
Form 1  
DMX  
Mode  
15  
LED Control model  
LED  
channel  
1~12  
Internal  
program  
13  
Strobe Dimmer/Speed  
Each  
control  
can  
can  
be  
be  
14  
15  
N/A  
4
channel controlled alone  
12 Each control  
channel controlled alone  
1~12  
1~3  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
4
Each color can be controlled  
Each color can be controlled  
channel  
3
1~3  
N/A  
channel  
Specification:  
When in 15 channel mode, the reciprocal 3rd, is the internal program channel, below the  
value:  
0---10  
11---40  
41---70  
71---100  
101---130  
131---160  
161---190  
191---220  
221---255  
No function  
Program 1  
Program 2  
Program 3  
Program 4  
Program 5  
Program 6  
Program 7  
Program 8  
When in 15 channel mode, the reciprocal 2rd channel is the Strobe channel, below the  
value:  
0
Open  
1----95  
Strobe from slow to fast  
Open  
Pulse strobe from slow to fast  
Open  
96----127  
128---159  
160---191  
192----223  
Random strobe  
©Elation Professional, Los Angeles Ca.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design LED 12 Brick II ™  
224---255  
Open  
If running the internal program, the tailender channel would be the speed of grogram from  
slow to fast.  
If not running the internal program, the tailender channel would be dimmer channel.  
2Display menu:  
<ADDR> AXXX (1-512) Set DMX address  
3 CH  
4 CH  
Select 3 channel mode  
Select 4 channel mode  
Select 12 channel mode  
Select 15 channel mode  
Run as slave.  
Run as master  
Set to stand alone  
BLACKOUT  
<CHAN>  
12CH  
15CH  
ON/OFF  
MAST  
ALON  
<SLAV>  
<CNTL>  
<BLAC>  
RED  
RXXX  
GXXX  
BXXX  
SXXX  
XXX  
XXX  
XXX  
XXX  
XXX  
XXX  
XXX  
XXX  
XXX  
XXX  
XXX  
XXX  
XXX  
XXX  
XXX  
XXX  
Adjust red LED Value  
GREN  
BLUE  
STRB  
SPED  
FADE  
STRB  
SPED  
FADE  
STRB  
SPED  
FADE  
STRB  
SPED  
FADE  
STRB  
SPED  
FADE  
STRB  
SPED  
Adjust green LED Value  
Adjust blue LED Value  
Adjust strobe value  
<COLR>  
Adjust speed of scene  
Adjust speed of fade  
Adjust speed of strobe  
Adjust speed of scene  
Adjust speed of fade  
Adjust speed of strobe  
Adjust speed of scene  
Adjust speed of fade  
Adjust speed of strobe  
Adjust speed of scene  
Adjust speed of fade  
Adjust speed of strobe  
Adjust speed of scene  
Adjust speed of fade  
Adjust speed of strobe  
Adjust speed of scene  
CHS1  
CHS2  
CHS3  
CHS4  
CHS5  
CHS6  
©Elation Professional, Los Angeles Ca.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design LED 12 Brick II ™  
FADE  
XXX  
Adjust speed of fade  
STRB  
SPED  
FADE  
STRB  
SPED  
FADE  
STRB  
MAST  
ALON  
M-XX  
MOD1  
MOD2  
XXX  
XXX  
XXX  
XXX  
XXX  
XXX  
XXX  
Adjust speed of strobe  
Adjust speed of scene  
Adjust speed of fade  
Adjust speed of fade  
Adjust speed of scene  
Adjust speed of fade  
CHS7  
CHS8  
CTRL  
Adjust speed of fade  
Sound-controlled run as Master  
Sound-controlled run in Stand Alone  
Microphone sensitivity  
Select standard dimmer  
Select weak dimmer  
MIC  
<DIMR>  
Reset to Fixture to the Factory Default  
Settings  
Show the version  
<LOAD> yes  
<VER> V X.X  
Remark:  
1) If there is no DMX data received in the device, the display will flash.  
2) Instruction for the SPED and the FADE function in CHAS:  
SPEED: The time one step would stay  
FADE: The time that one step altered to next step  
Example: we set SPEED ==1second, and FADE ==1second, the 1st step is Red 100% open,  
the 2nd step is green 100% open, the 3rd step is Blue 100% open. So, the Chase would  
come out as:  
1, The Red 100% open and stay for 1second (SPEED)  
2, Then Red drop down from 100% to 0%, the same time Green from 0% to 100%, in  
1second (FADE)  
3, The Green stay 100% for 1second  
4, Then Green drop down from 100% to 0%, the same time Blue from 0% to 100%, in  
1second (FADE)  
5, Blue stay 100% for 1 second.  
6, Then Blue drop down from 100% to 0%, the Red come up from 0% to 100%  
Repetition operation  
©Elation Professional, Los Angeles Ca.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design LED 12 Brick II ™  
DMX Operation Notes:  
The fixture will automatically function in DMX mode whenever the unit receives a DMX  
signal. Please note that this will override all manual settings regardless of dipswitch  
positions.  
This unit will keep and retain the last DMX command in the event of DMX signal failure. To  
reset the fixture you must turn the power off.  
©Elation Professional, Los Angeles Ca.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design LED 12 Brick II ™  
9. DMX CHANNEL TRAITS  
4 Channel Mode: This chart details a simple layout of the DMX channel assignment in  
4-channel mode. The chart traits will vary slightly for 3-channel, 12-chennel, and 15-channel  
operation, as those modes use more RGB channels for more precise control.  
1
2
3
4
CHANNEL 1: Red  
CHANNEL 2: Green  
CHANNEL 3: Blue  
CHANNEL 4: Dimming (0%-100%)  
©Elation Professional, Los Angeles Ca.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design LED 12 Brick II ™  
DMX channel’s functions and their values (4 Channel Mode):  
Channel 1 - Red:  
0-255  
Red (0-Black, 255-100% Red)  
Channel 2 - Green:  
0-255  
Green (0-Black, 255- 100% Green)  
Channel 3 - Blue:  
0-255  
Blue (0-Black, 255- 100% Blue)  
Channel 4 - General dimming  
0-255  
Dimming (0%-100%) ~ Normal Operation  
©Elation Professional, Los Angeles Ca.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design LED 12 Brick II ™  
10. CLEANING AND MAINTENANCE  
The consider the following point during normal service and inspection:  
1. Be sure all screws and fasteners are securely tightened at all times. Lose screws may  
fall out during normal operation resulting in damage or injury as larger parts could fall.  
2. Electric power supply cables must not show any damage, material fatigue or  
sediments. Never remove the ground prong from the power cable.  
Further instructions depending on the installation spot and usage have to be adhered by a  
skilled installer and any safety problems have to be removed.  
Disconnect from mains before starting maintenance operation.  
We recommend a frequent cleaning of the device. Please use a moist, lint- free cloth. Never  
use alcohol or solvents.  
There are no user serviceable parts inside this, please refer all other service issues to an  
authorized Elation service technician.  
Should you need any spare parts, please order genuine parts from your local dealer.  
©Elation Professional, Los Angeles Ca.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design LED 12 Brick II ™  
11.2-YEAR LIMITED WARRANTY  
A. Elation Professional® hereby warrants, to the original purchaser, Elation Professional®  
products to be free of manufacturing defects in material and workmanship for a period of two  
years, (730 days) from the date of purchase. This warranty shall be valid only if the product  
is purchased within the United States of America, including possessions and territories. It is  
the owner’s responsibility to establish the date and place of purchase by acceptable  
evidence, at the time service is sought.  
B. For warranty service, send the product only to the Elation Professional® factory. All  
shipping charges must be pre-paid. If the requested repairs or service (including parts  
replacement) are within the terms of this warranty, Elation Professional® will pay return  
shipping charges only to a designated point within the United States. If the entire instrument  
is sent, it must be shipped in its original package. No accessories should be shipped with the  
product. If any accessories are shipped with the product, Elation Professional® shall have no  
liability what so ever for loss of or damage to any such accessories, nor for the safe return  
thereof.  
C.  
This warranty is void if the serial number has been altered or removed; if the product is  
modified in any manner which Elation Professional® concludes, after inspection, affects the  
reliability of the product; if the product has been repaired or serviced by anyone other than  
the Elation Professional® factory unless prior written authorization was issued to purchaser  
by Elation Professional®; if the product is damaged because not properly maintained as set  
forth in the instruction manual.  
D. This is not a service contract, and this warranty does not include maintenance, cleaning  
or periodic check-up. During the period specified above, Elation Professional® will replace  
defective parts at its expense, and will absorb all expenses for warranty service and repair  
labor by reason of defects in material or workmanship. The sole responsibility of Elation  
Professional® under this warranty shall be limited to the repair of the product, or replacement  
thereof, including parts, at the sole discretion of Elation Professional®. All products covered  
by this warranty were manufactured after January 1, 1990, and bare identifying marks to that  
©Elation Professional, Los Angeles Ca.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design LED 12 Brick II ™  
effect.  
E.  
Elation Professional® reserves the right to make changes in design and/or  
improvements upon its products without any obligation to include these changes in any  
products theretofore manufactured.  
F. No warranty, whether expressed or implied, is given or made with respect to any  
accessory supplied with products described above. Except to the extent prohibited by  
applicable law, all implied warranties made by Elation Professional® in connection with this  
product, including warranties of merchantability or fitness, are limited in duration to the  
warranty period set forth above. And no warranties, whether expressed or implied, including  
warranties of merchantability or fitness, shall apply to this product after said period has  
expired. The consumer’s and or Dealer’s sole remedy shall be such repair or replacement as  
is expressly provided above; and under no circumstances shall Elation Professional® be  
liable for any loss or damage, direct or consequential, arising out of the use of, or inability to  
use, this product.  
G. This warranty is the only written warranty applicable to Elation Professional® Products  
and supersedes all prior warranties and written descriptions of warranty terms and  
conditions heretofore published.  
©Elation Professional, Los Angeles Ca.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design LED 12 Brick II ™  
12.  
PHOTOMETRIC DATA  
Beam angle 44  
°
480  
144  
76  
IntensityLUX  
Distance (m)  
Diameter (m)  
0
0
1
0.8  
2
1.6  
3
2.4  
©Elation Professional, Los Angeles Ca.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design LED 12 Brick II ™  
15. DIMENSIONAL DRAWINGS  
14.  
CHANGE LENS TO GET DIFFERENT BEAM ANGLES  
©Elation Professional, Los Angeles Ca.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design LED 12 Brick II ™  
15.  
CIRCUIT SCHEMATIC  
©Elation Professional, Los Angeles Ca.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design LED 12 Brick II ™  
16.  
TECHNICAL SPECIFICATIONS  
Power supply:  
Power consumption:  
LED Configuration:  
Packing dimensions:  
Weight:  
100V~240V AC, 50Hz~60Hz  
MAX 30w  
12 1Watt Units (4 x Red, 4x Green 4 x Blue)  
47x26.5x16cm (57x47x36cm ~ 4pc system)  
3.5Kgs / 7.72 Lbs (14Kgs ~ 4pc system  
3, 4, 12, 15 DMX Channel modes  
Standard DMX-512, 3 pole XLR; [+] = Pin 3, [-] = Pin 2,  
[Ground] = Pin 1 or Standard DMX-512, 5 pole XLR; n/a  
= Pin 5, n/a = Pin 4, [+] = Pin 3, [-] = Pin 2, [Ground] =  
Pin-  
DMX Channels:  
Drive:  
Color Mixing:  
Beam Angle:  
Fuse:  
RGB Color Additive Mixing  
44˚  
GMA 250V~2A  
Dimmer:  
Continuous Dimming 0~100%  
Strobe:  
Electronic Strobe 0~18 Fps  
Lamp Life:  
100,000 Hours Rated Life  
Please Note: Specifications and improvements in the design of this unit and this manual are subject to  
change without any prior written notice.  
©Elation Professional, Los Angeles Ca.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design LED 12 Brick II ™  
Elation Professional  
6122 S. Eastern Ave.  
Los Angeles, CA. 90040  
323-582-3322 / 323-582-3108 fax  
©Elation Professional, Los Angeles Ca.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Fellowes Laminator GXL 125 User Manual
Fisher Price Bouncy Seat M2055 User Manual
Fluke Portable Multimedia Player 8842a User Manual
Franke Consumer Products Range FDF 9174 I User Manual
Fujitsu Server M10 4 User Manual
Fundex Games Games 3830 00 User Manual
Furuno Telephone FM 8700 User Manual
Gaggenau Ventilation Hood 900791 User Manual
GE Blender 106757 User Manual
Gianni Industries Door DG 26 User Manual