1
2
Description of Device..........................................................................................................7  
1.1 Safety Instructions.......................................................................................................8  
Preparation and Installation..............................................................................................9  
2.1 Mounting........................................................................................................................9  
2.1.1 Clamps ..............................................................................................................9  
POWER WASH 575E  
2.2 Secure the POWER WASH 575E.....................................................................10  
2.3 Connections..............................................................................................................11  
2.3.1 Power supply .................................................................................................11  
2.3.2 DMX.................................................................................................................11  
2.4 Fuse............................................................................................................................11  
3
The Menu Field...................................................................................................................12  
3.1 Adjust the DMX- Address (D001)..........................................................................13  
3.2 The Test Program (TEST)....................................................................................14  
3.3 The Audio Program (AUDI)..................................................................................14  
3.4 Lamp On/Off (LAMP).............................................................................................14  
3.5 Reset (RESE)..........................................................................................................15  
3.6 Running time of lamp and unit (TIME)..............................................................15  
3.7 Continuous Color Wheel (FCOL)........................................................................15  
3.8 Invert Pan Movement (RPAN)...............................................................................15  
3.9 Invert Tilt Movement (RTLT).................................................................................15  
3.10 Special Functions (SPEC).....................................................................................16  
3.10.1Manual Drive (MANU)...............................................................................16  
3.10.2Lamp On automatically (LAAU)..............................................................16  
3.10.3Lamp Off via DMX (DLOF)........................................................................17  
3.10.4DMX Input (DMXI)......................................................................................17  
3.10.5Display (DISP).............................................................................................18  
3.10.6Fixture Temperature (TEMP)....................................................................18  
3.10.7Fan Control (FANS)....................................................................................18  
3.10.8Adjustments and Calibrations (ADJU)....................................................19  
3.10.9Default Settings (DFSE).............................................................................20  
3.10.10 Position Feedback (FEED).................................................................20  
3.10.11 Correction of faults (EFLG)..................................................................20  
Elation Lighting  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.11 Error and Information Messages...........................................................................20  
4
5
DMX Channel Selection (DMX Protocol).......................................................................22  
Change the Lamp...............................................................................................................24  
5.1 Safety Regulations....................................................................................................24  
5.2 Realize the Lamp Change ......................................................................................24  
POWER WASH 575E  
Maintenance and Cleaning the POWER WASH 575E...........................................25  
6
6.1 Safety Regulations....................................................................................................25  
6.2 Circumference and Interval (rule-of-thumb).........................................................25  
6.3 Cleaning the Optical System..................................................................................26  
7
8
Technical Specification....................................................................................................26  
Index .....................................................................................................................................30  
Elation Lighting  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTRODUCTION: Congratulations, you have just purchased one of the most  
innovative and reliable lighting fixtures on the market today! The Power Wash 575E™,  
has been designed to perform reliably for years when the guidelines in this booklet are  
followed. Please read and understand the instructions in this manual carefully and  
thoroughly before attempting to operate this unit. These instructions contain  
important information regarding safety during use and maintenance.  
UNPACKING: Thank you for purchasing the Power Wash 575E™ by Elation  
Professional®. Every Power Wash 575E™ has been thoroughly tested and has been  
shipped in perfect operating condition. Carefully check the shipping carton for  
damage that may have occurred during shipping. If the carton appears to be  
damaged, carefully inspect your unit for damage and be sure all accessories  
necessary to operate the unit have arrived intact. In the event damage has been found  
or parts are missing, please contact our customer support team for further  
instructions. Please do not return this unit to your dealer without first contacting  
customer support at the number listed below.  
CUSTOMER SUPPORT: Elation Professional® provides a customer support line, to  
provide set up help and to answer any question should you encounter problems  
during your set up or initial operation. You may also visit us on the web at  
please contact Elation Professional®. Service Hours are Monday through Friday 9:00  
a.m. to 5:00 p.m. Pacific Standard Time.  
Voice:  
Fax:  
(323) 582-3322  
(323) 582-3108  
E-mail:  
Forum:  
Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this  
unit to rain or moisture.  
Caution! There are no user serviceable parts inside this unit. Do not attempt any  
repairs yourself, doing so will void your manufactures warranty.  
Please do not discard the shipping carton in the trash. Please recycle whenever  
possible.  
Elation Lighting  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTY REGISTRATION: The Power Wash 575E™ carries a two year (730  
days) limited warranty. Please fill out the enclosed warranty card to validate your  
purchase. All returned service items whether under warranty or not, must be freight  
pre-paid and accompany a return authorization (R.A.) number. The R.A. number must  
be clearly written on the outside of the return package. A brief description of the  
problem as well as the R.A. number must also be written down on a piece of paper  
and included in the shipping container. If the unit is under warranty, you must provide  
a copy of your proof of purchase invoice. Items returned without a R.A. number clearly  
marked on the outside of the package will be refused and returned at cutomers  
exspence. You may obtain a R.A. number by contacting customer support at (323)  
582-3322.  
DISCHARGE LAMP WARNING: This fixture is fitted with a  
discharge lamp, which is highly susceptible to damage if  
improperly handled. Never touch the lamp with your bare hands, as  
the oil from your hands will shorten lamp life. Also, never move the  
fixture until the lamps have had ample time to cool. Remember,  
lamps are not covered under warranty conditions.  
This fixture emits intense UV radiation, which is harmful to the eyes and skin. The  
intense luminance of the lamp can cause severe damage to the retina. Never operate  
this fixture with the protective covers removed, these covers have been specially  
designed to shield against UV radiation.  
Epileptic Warning: Those suffering from epilepsy should avoid looking directly into  
the lamp at all times.  
Avoid switching the fixture on and off repeatedly in short intervals, as this will reduce  
lamp life and intensity.  
To achieve the intensity associated with discharge lamps, these lamps use a gas  
sealed in a high-pressure environment to emit a brilliant output. Due to the high  
pressure involved with the construction of the lamp, the lamp may explode during  
prolonged extensive use. This risk is increased with age; added care is encouraged  
when dealing with older lamps. Thus, lamp should always be replaced at the end of  
their recommended duty cycle. Extreme caution should be used when operated this or  
any fixture fitted with a gas discharge lamp.  
Never open this fixture while in use!  
During the initial operation of this fixture, a light smoke or smell may emit from the  
interior of the fixture. This is a normal process and is caused by excess paint in the  
interior of the casing burning off from the heat associated with the lamp.  
Elation Lighting  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
1 Description of Device  
1
4
1. Moving Head  
2. Carrying handles  
3. LED- Display  
4. Arm  
5. Camlock system  
3
2
5
8
9
15  
6. Software-Update  
connector  
DMX IN  
DMX OUT  
7. Microphone- Intensity  
8. DMX- Input  
1.Ground  
2.Data  
3.Data  
-
+
Min  
M
a
x
Mic Sensvitiity  
Software Update  
9. DMX- Output  
10. Fan (air inlet/outlet)  
7
10  
14  
6
13  
10  
15  
11.  
Power On/Off  
12. Mains supply  
(Powercon)  
Lamp Fuse  
ElectronicFuse  
Power input:90  
50  
-
/
260AVC,  
60Hz  
POWER  
13. Fuse lamp  
14. Fuse electronics  
15. Carrying handles  
12  
11  
Elation Lighting  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.1 Safety Instructions  
POWER WASH 575E  
The POWER WASH 575E is a High-Tech Product. To  
guarantee a smooth operation, it is necessary to keep  
following rules.  
The manufacturer of this device will not take responsibility of  
damages through disregard of the information in this manual.  
Warranty adjustments will be cancelled.  
1. Make sure before putting into operation, that the fan and the air inlets are  
clean and not blocked by anything.  
2. Attention: Don’t touch the device during the operation. This can cause  
injuries or damages.  
POWER WASH 575E  
3. Unplug the POWER WASH 575E from the AC outlet before any  
attempting any service.  
4. It is necessary to wait at least 30 minutes after disconnecting the AC before  
POWER WASH 575E  
you open the POWER WASH 575E. Please do not touch the bulb of the  
lamp if you are not absolutely sure it is cold. -- Danger of BURNING --  
5. Never look directly into the beam of the lamp. You risk injury of your retina  
and blindness.  
6. Pay attention of the maximum lamp operation time. You have to change it if  
the lamp shows any deformations or damages. The same is with all glass  
components, color filters, lenses and mirrors.  
7. To allow a secure operation, follow also the Installation guide described in  
POWER WASH 575E  
chapter 2. Operating the POWER WASH 575E without suited safety aids  
like Safety cables or clamps/hooks can increase the risk of an accident.  
8. Installation should be done by qualified staff only. You need to pay attention  
to the common rules of technology that are not explicitly mentioned in this  
manual.  
9. Use only original spare parts. Any structural modification will cancel all  
warranty adjustments.  
Elation Lighting  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 Preparation and Installation  
2.1 Mounting  
POWER WASH 575E  
The POWER WASH 575E is fully operational whether it hangs or is mounted  
to the wall. It can also be operated while standing on the floor. Keep a safety  
distance of 0.5 m towards any easy inflammable materials (decoration etc.).  
Install a safety wire that can hold at least 10 times the weight of the fixture. Never  
use the carrying handles for secondary attachment.  
Pay attention to the regulations of: BGV C1 (former VBG 70) and  
DIN VDE 0711-217 !  
The installation should be done by qualified staff only.  
2.1.1 Clamps  
POWER WASH 575E  
There are two major possibilities to mount the POWER WASH 575E  
together with clamps. Camlock system or direct mounting of clamps. In  
both cases you have to regard a sufficient stability of the system. For  
installation instructions please see also printing on the backside of the  
case.  
Elation Lighting  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
a) Camlock system: This system allows you a fast and efficient setup of  
clamps. Attach the two camlocks to designated position on the  
backside of the case and close the locks by turning them 90°. Verify  
the secure fit of the camlock system. The clamps themselves are  
directly attached permanently on the camlocks.  
90°  
POWER WASH 575E  
b) Use two clamps direct on the backside of the POWER WASH 575E  
to mount the unit on a truss (each two opposite threads max. M10x20).  
4x M10x20mm  
4x Camlock  
POWER WASH 575E  
2.2 Secure the POWER WASH 575E  
POWER WASH 575E  
Regardless of the rigging of the POWER WASH 575E you have to use a  
stipulated safety wire. Therefore you have to thread to safety wire through to two  
provided holes on the backside of the fixture and connect it with the truss-  
support. Pay attention to a safe and proper fastening.  
Elation Lighting  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.3 Connections  
2.3.1 Power supply  
Electronic ballast with:  
~90 - 260 Volt, 50 - 60 Hz, earth contact type plug - Powercon  
Connected load 780W <=> 3.8 A (blind current compensation).  
Please see printing on the case for the right electronic supply!  
2.3.2 DMX  
DMX 512 Standard input/output. See also printing on the case for the right  
pin assignment.  
[+] = Pin 3 / [-] = Pin 2 / [Ground] = Pin 1  
The DMX- Addressing starts at the DMX- Address [001].  
2.4 Fuse  
POWER WASH 575E  
The POWER WASH 575E electronic system is protected by two 5x20 mm fine-  
wire fuses.  
Lamp: 230V / T 5A  
Electronic: 230V / T 1A  
POWER WASH 575E  
Please see the printing on the POWER WASH 575E casing for more details.  
Attention:  
Disconnect AC outlet before changing a fuse!  
Use only the original declared fuse type!  
Elation Lighting  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 The Menu Field  
You’ll find the control board on the side part of the base. It allows you to  
POWER WASH 575E.  
make all necessary adjustments of the POWER WASH 575E. With the  
MODE ENTER DOWN UP  
Mode-key you get into the main menu. Afterwards you can navigate through  
the menu with the Up/Down-keys. Push the Enter-key to get in the next  
menu level or to confirm your settings. Make them and set functions ON/OFF  
with the Up/Down-keys. Confirm and save it with the Enter-key (the display  
shows OK). Push the Mode-key to cancel the entry and go back to the main  
menu.  
MODE ENTER DOWN UP  
Display  
M N E O D  
Level 1  
D001  
Level 2  
Level 3  
Remark  
Define the DMX start address  
Test program of all functions  
TEST  
AUDI  
Self-running audio program (slow)  
Self-running audio program (fast)  
Master for the audio program  
ASLW  
AFST  
MSTR  
SVPT  
SIZE  
Basic position for the audio program  
Size for the audio program (NORM-BIG-MIDL-SMAL)  
POWER WASH  
Switch on/of the lamp direct at the POWER WASH  
LAMP  
575E  
575E  
Reset  
RESE  
TIME  
Running time of the fixture (no destructible)  
Running time of the lamp (erasable)  
Running time of the lamp (no destructible)  
Reverse Pan-direction  
POWR  
LA1  
LA2  
FCOL  
RPAN  
RTLT  
SPEC  
Reverse Tilt-direction  
Manual drive of all device functions  
Automatic lamp start  
MANU  
LAAU  
DLOF  
DMXI  
DISP  
Switch off lamp via DMX  
Reed out actual DMX-values  
Display On/Off  
Twist the display  
D ON  
REV  
Reed out internal temperature  
Maximum cooling fan velocity  
Automatic cooling fan control  
Low cooling fan speed lamp off  
Low cooling fan speed automatic  
Define the DMX start address  
TEMP  
FANS  
HIGH  
REG  
LOOF  
LOHI  
CODE  
xxxx  
ADJU  
Use the code for entering the calibration menu (for  
authorized persons only)  
Calibration of the Cyan color wheel  
Calibration of the Magenta color wheel  
Calibration of the Yellow color wheel  
Calibration of the color wheel  
CYAN  
MAGE  
YELL  
COLO  
BSPR  
Calibration of the beam shape  
Elation Lighting  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Calibration of the Zoom  
ZOOM  
Dimm  
SHUT  
CLRE  
ARES  
VTIL  
VTRB1  
VTRB2  
CODE  
xxxx  
Calibration of the Dimmer  
Calibration of the Shutter  
Settings in the internal memory (super-user only)  
Adjust Reset  
Software version Tilt-board  
Software version driver board 1  
Software version driver board 2  
Use the code for entering the calibration menu (for  
authorized persons only)  
COAD  
Coarse calibration of the Cyan color wheel  
Coarse calibration of the Magenta color wheel  
Coarse calibration of the Yellow color wheel  
Call on the default function values  
CYAN  
MAGE  
YELL  
DFSE  
FEED  
EFLG  
Pan/Tilt feedback (error correction) On/Off  
Correction of faults  
3.1 Adjust the DMX- Address (D001)  
POWER WASH 575E  
Right after turning on the POWER WASH 575E you can see the current DMX-  
Address. If there is no DMX- Signal the display flashes.  
D001  
For the address setting please follow this procedure:  
POWER WASH 575E  
1. Switch On the POWER WASH 575E and wait until the fixture reset has  
finished ('RESE' is flashing in the display).  
2. Press the Mode-key in order to access the main menu. Browse through the  
menu by pressing the Up/Down-keys until the display shows D001. Confirm  
by pressing the Enter-key (the decimal point is flashing)  
3. Use the Up/Down-keys to select the desired address. Confirm the setting by  
pressing the Enter-key (the display shows OK) or press the Mode-key to  
cancel.  
POWER WASH 575E  
The DMX- Address is stored also while switching off the POWER WASH 575E!  
Elation Lighting  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.2 The Test Program (TEST)  
test  
The Test-Program allows you to run a complete self test procedure of all  
functions. Press Enter to confirm or Mode to cancel.  
3.3 The Audio Program (AUDI)  
Audi  
The Audio-menu allows you to run a stand alone audio program. This chaser  
can run either fast or slow. AFST: Every sound impulse on step of the chaser.  
Aslw: Every second sound impulse one step of the chaser.  
Additional you can choose a basic position for this audio chaser. Use therefore  
either the internal manual mode or an external controller to set the desired  
Pan/Tilt position. Confirm this setting in the SVPT menu by pressing the Enter-  
key.  
You can also set the size of the audio chaser in the SIZE menu. You have the  
choice between: NORM (no basic position has to bee chosen), BIG, MIDL  
and SMAL).  
YPOCs  
If you want to run the systems simultaneously, one of the YPOCs must be  
switched as the master. All others must be "Slave" Master = OFF. Notice: The  
Audio function is only working if no DMX is connected. This function can work e.g.  
on small events or as an emergency program.  
3.4 Lamp On/Off (LAMP)  
LAMP  
Use the Up/Down-keys to select lamp On or lamp Off Press Enter to confirm or  
Mode to cancel and return to the main menu. (The lamp OFF command is only  
working if the shutter is closed at the same time. Use an external controller or  
the manual drive mode, see chapter 3.10.1.  
Elation Lighting  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.5 Reset (RESE)  
RESE  
Press the Enter-key to run a reset of all fixture functions (RST is shown in the  
display).  
3.6 Running time of lamp and unit (TIME)  
TIME  
By this option can read out three different running times of the fixture.  
Running time of the fixture (no destructible).  
POWR  
Running time of the lamp (erasable). Push the Up/Down-keys at one  
time to delete this running time.  
LA 1  
Running time of the lamp (no destructible).  
LA 2  
3.7 Continuous Color Wheel (FCOL)  
fcol  
This function allows you to control the color wheel continuously. If it is switched  
off, the color wheel is stepping directly from one to another color.  
3.8 Invert Pan Movement (RPAN)  
RPAN  
This function allows you to invert the Pan movement. Use the Up/Down-keys to  
select invert On or Off. Press Enter to confirm or Mode to cancel and return to  
the main menu.  
3.9 Invert Tilt Movement (RTLT)  
RTLT  
This function allows you to invert the Tilt movement. Use the Up/Down-keys to  
select invert On or Off. Press Enter to confirm or Mode to cancel.  
Elation Lighting  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.10 Special Functions (SPEC)  
SPEC  
POWER WASH  
This menu allows you to enter further special functions of the POWER WASH  
575E.  
575E.  
In detail they are:  
3.10.1 Manual Drive (MANU)  
MANU  
This function allows you to drive all the fixture functions manually. Select  
the desired function with the Up/Down-keys and confirm with Enter. Now  
choose the desired value with the Up/Down-keys and confirm again with  
Enter or cancel and return to the menu with the Mode-key.  
Function  
PAN  
TILT  
CYAN  
MAGE  
YELL  
COLO  
SHUT  
Value  
Remark  
Pan Position  
000 - 255  
000 - 255  
000 - 255  
000 - 255  
000 - 255  
000 - 255  
000 - 255  
Tilt Position  
Cyan color wheel  
Magenta color wheel  
Yellow color wheel  
Color wheel (fixed colors)  
Shutter / Strobe function (the lamp strikes at  
DMX 255 if dimmer is "open" = DMX 255)  
Dimmer  
DIMR  
BSPR  
ZOOM  
SPEC  
000 - 255  
000 - 255  
000 - 255  
000 - 255  
Beam shape + Frost  
Zoom  
Lamp Off, Reset, ...  
3.10.2 Lamp On automatically (LAAU)  
LAAU  
This function enables to switch On the lamp automatically after switching  
On the fixture. Use the Up/Down-keys to select ON if you want to switch  
on the lamp automatically after switching on the fixture or Off if you don't  
want this function. Press Enter to confirm or Mode to cancel and return to  
the menu.  
Elation Lighting  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
If you have chosen off you have the possibility to start the lamp either via  
POWER WASH 575E  
DMX or direct at the POWER WASH 575E in the Lamp menu.  
3.10.3 Lamp Off via DMX (DLOF)  
DLOF  
This function enables to switch off the lamp via DMX or not. Use the  
Up/Down-keys to select ON if you want to switch off the lamp via DMX or  
Off if you don't want this function. Press Enter to confirm or Mode to  
cancel and return to the menu.  
If you have chosen off you have the possibility to switch off the lamp  
POWER WASH 575E  
either direct at the POWER WASH 575E in the Lamp menu or switch off  
the main switch.  
3.10.4 DMX Input (DMXI)  
DMXI  
Readout DMX values of each channel received by the fixture. Use the  
Up/Down-keys to select desired channel and press Enter to read its  
value.  
Function  
PAN  
TILT  
Value  
0 - 255  
0 - 255  
0 - 255  
0 - 255  
0 - 255  
0 - 255  
0 - 255  
0 - 255  
0 - 255  
0 - 255  
0 - 255  
0 - 255  
0 - 255  
Remark  
Pan Position  
Tilt Position  
Cyan color wheel  
Magenta color wheel  
Yellow color wheel  
Color wheel (fixed colors)  
Shutter / Strobe function  
Dimmer  
CYAN  
MAGE  
YELL  
COLO  
SHUT  
DIMR  
BSPR  
ZOOM  
SPEC  
MOVE  
SPED  
Beam shape + Frost  
Zoom  
Lamp Off, Reset, ...  
Movement  
Speed for Pan/Tilt  
Elation Lighting  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.10.5 Display (DISP)  
DISP  
Use this function to choose between different display indications. Use the  
Up/Down-keys to select desired function and press Enter to confirm or  
Mode to cancel and return to the menu.  
D ON Display On/Off (If you've chosen off, the display will go out within  
15 seconds after the last input. The next key touch will reactivate  
the display).  
Turn around the display.  
REV  
Note: You can also do this by pushing the Up/Down-keys at the  
same time.  
3.10.6 Fixture Temperature (TEMP)  
TEMP  
This function allows you to read out the actual temperature of the  
POWER WASH 575E  
POWER WASH 575E. Press Enter to confirm or Mode to cancel. Inside  
temperatures below 80°C are not critical. 80°C and more lead the lamp  
being switched off at a critical point. Please note for a save operation that  
the outside temperature should not exceed 45°C.  
3.10.7 Fan Control (FANS)  
FANS  
By using this function you can choose between 4 types of fan speed  
operations. Use the Up/Down-keys to select desired function and press  
Enter to confirm or Mode to cancel and return to the menu.  
The cooling fan works continuously at max. speed.  
HIGH  
The fan automatically raises its speed in order to control inside  
temperature of the fixture.  
REG  
The fan keeps the adjusted low speed until the temperature  
POWER WASH  
exceeds max. inside temperature, then the POWER WASH  
LOOF  
575E  
575E automatically switch off the lamp.  
The fan keeps the adjusted low speed until the temperature  
POWER WASH  
exceeds max. inside temperature, then the
POWER WASH  
LOHI  
Elation Lighting  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
POWER WASH  
exceeds max. inside temperature, then the POWER WASH  
575E  
575E automatically switch from low to high fan speed.  
In addition to these settings, you can set to fan speed to minimum via  
DMX (Special channel, DMX value 224..229). This will last until a tempera-  
ture of 90° is reached.  
3.10.8 Adjustments and Calibrations (ADJU)  
ADJU  
By this function you can adjust and calibrate the positions of the different  
wheels and other motors. This can be necessary after a service or repair  
work.  
For this function you have to entry the fixture code. This work should be  
done only by authorized persons.  
Use the Up/Down-keys to select desired function and press Enter to  
confirm or Mode to cancel and return to the menu. Use now the Up/Down-  
keys to set the adjustment values and confirm once more with the Enter-  
key or cancel with the Mode-key.  
Function  
Value  
CODE  
xxxx  
Remark  
Adjustments in the internal setup are code protec-  
ted (for authorized persons only).  
ADJU  
Adjustment of the Cyan color wheel  
Adjustment of the Magenta color wheel  
Adjustment of the Yellow color wheel  
Adjustment of the Color wheel  
Adjustment of the Beam shape  
Adjustment of the Zoom  
CYAN - 99 - + 99  
MAGE - 99 - + 99  
YELL - 99 - + 99  
COLO - 99 - + 99  
BSPR - 99 - + 99  
ZOOM - 99 - + 99  
DIMM - 99 - + 99  
SHUT - 99 - + 99  
Adjustment of the Dimmer  
Adjustment of the Shutter  
Adjustments in the internal circuit.  
CLRE  
Adjust Reset (wheels stand still after the reset)  
Software version of Tilt-board  
ARES - 99 - + 99  
VTIL  
- 99 - + 99  
Software version of Head- board  
Software version of Base- board  
VTR1 - 99 - + 99  
VTR2 - 99 - + 99  
Adjustments in the internal setup are code protec-  
ted (for authorized persons only).  
COAD  
CODE  
xxxx  
Coarse adjustment of the Cyan color wheel  
CYAN - 99 - + 99  
Elation Lighting  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Coarse adjustment of the Magenta color wheel  
Coarse adjustment of the Yellow color wheel  
MAGE - 99 - + 99  
YELL - 99 - + 99  
3.10.9 Default Settings (DFSE)  
DFSE  
Press Enter to reset all fixture personalities (not the adjusted functions) to  
the default values. On the display will appear ok to indicate that the de-  
faults are set.  
Function  
DMX Address  
Display  
D001  
Default Settings  
D001  
Pan reverse  
Tilt reverse  
RPAN  
RTLT  
LAAU  
DLOF  
DISP  
ON  
ON  
ON  
ON ¸  
D ON ¸  
OFF ¸  
OFF ¸  
OFF ¸  
OFF  
Automatic lamp on  
Lamp on via DMX  
Display  
Cooling fan  
FANS  
FEED  
HIGH REG ¸ LOOF LOHI  
ON ¸ OFF  
Feedback  
3.10.10 Position Feedback (FEED)  
FEED  
POWER WASH 575E  
The POWER WASH 575E is provided with a automatic position  
correction (feedback) for the Pan and Tilt movement. Use the Up/Down-  
keys to select ON if you want to enable the feedback function or Off if you  
don't want this function. Press Enter to confirm or Mode to cancel and  
return to the menu.  
3.10.11 Correction of faults (EFLG)  
EFLG  
(Function available for authorized persons only)  
3.11 Error and Information Messages  
This message appears if you try to switch on the lamp within 5  
minutes after having switched off (lamp too hot). The message
 
will  
HEAt  
Elation Lighting  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
minutes after having switched off (lamp too hot). The message will  
appear on the display if the lamp doesn’t ignite within 20 seconds.  
The fixture will store this command and automatically ignite the lamp  
after 5 minutes.  
When igniting the lamp, the electronic ballast will examine whether the  
lamp ignited or not. If the lamp does not ignite within 20 seconds, the  
igniting sequence is broken off. Now approx. 2 minutes are waited,  
until a renewed ignition attempt is started automatically. After the 3rd  
unsuccessful ignition attempt the sequence is completely stopped  
IG E  
and the display reads "IG E" (Ignition error).  
As soon as the lamp ignited correctly, the lamp current is constantly  
supervised by the system. If an interruption steps on (covers opened  
or lamp damaged), the power is switched off immediately. The display  
LAER  
reads "LAER" (lamps error). Please switch off the power supply and  
solve the possible problem.  
After the error "IG E" respectively "LAER" it is not anymore possible the start  
the lamp via Shutter = 255. Nevertheless if a renewed ignition attempt is  
desired, first run a Reset (at the Spot or over DMX). Afterwards you can try again  
to ignite the lamp.  
This error message informs you that the fixture was overheating and  
OTMP  
that the relay switches off the lamp. Pleas look for possible reasons  
(fan faulty, air in/outlets blocked or very dirty, lamp broken or very old,  
too high ambient temperature. Switch off the power supply and solve  
the possible problem.  
This message informs you that one of the fixture function wasn’t able  
to do its reset correct (magnetic sensor, stepping motor, driver on the  
PCB, cables, etc.). Repair the defect and start the fixture again.  
RsER  
Elation Lighting  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 DMX Channel Selection (DMX Protocol)  
Channel  
Function  
Time and Value  
min. 2,65 s  
DMX  
HEX  
%
1) PAN-  
coarse  
0 .. 530°  
0..255  
00..FF 0..100  
2) PAN-fine Low- Pos ... High- Pos + 2,1° (16 Bit)  
0..255  
0..255  
00..FF 0..100  
00..FF 0..100  
3) Tilt-  
0 .. 285°  
min. 1,8 s  
coarse  
4) Tilt-fine  
5) Color*  
Low- Pos … High- Pos + 1,1° (16 Bit)  
open (fast)  
color 1, Brilliant Blue (fast)  
color 2, Blue (fast)  
0..255  
0..3  
4..7  
00..FF 0..100  
Chaser from color to  
color max. 140 BPM  
0,43 s  
00..03  
04..07  
08..0B  
0,2  
1,8  
3,3  
8..11  
color 3, Blue Purple (fast)  
color 4, Pink (fast)  
color 5, Orange (fast)  
color 6, Italian Blue (fast)  
color 7, Turquoise (fast)  
color 8, Jade (fast)  
color 9, CTB 001 (fast)  
color 10, CTO 02 (fast)  
color 11, Red (fast)  
open (fast)  
open (slow)  
color 1, Brilliant Blue (slow)  
color 2, Blue (slow)  
color 3, Blue Purple (slow)  
color 4, Pink (slow)  
12..15 0C..0F  
4,9  
6,5  
8,0  
9,6  
16..19  
20..23  
10..13  
14..17  
24..27 18..1B  
28..31 1C..1F  
11,2  
12,7  
14,3  
15,9  
17,5  
19,0  
25,3  
26,9  
28,4  
30,0  
31,6  
33,1  
34,7  
36,3  
37,8  
39,4  
32..35  
36..39  
20..23  
24..27  
40..43 28..2B  
44..47 2C..2F  
48..63  
64..67  
68..71  
30..3F  
40..43  
44..47  
Chaser from color to  
color max. 70 BPM  
0,86 s  
72..75 48..4B  
76..79 4C..4F  
80..83  
84..87  
50..53  
54..57  
color 5, Orange (slow)  
color 6, Italian Blue (slow)  
color 7, Turquoise (slow)  
color 8, Jade (slow)  
88..91 58..5B  
92..95 5C..5F  
96..99  
60..63  
color 9, CTB 001 (slow)  
100..10 64..67  
3
color 10, CTO 02 (slow)  
color 11, Red (slow)  
104..10 68..6B  
41,0  
42,5  
44,1  
7
108..11 6C..6F  
1
112.127 70..7F  
open (slow)  
color rotation, slow-fast, CW  
min. 1.4 turns/h  
128..19 80..BF 50..75  
1
color rotation, fast-slow, CCW  
Audio color chaser slow  
Audio color chaser fast  
max. 2.9 turns/sec.  
192..25 C0..FD 76..98  
3
each 4th sound impulse  
new color  
each sound impulse  
new color  
254  
FE  
99  
255  
FF  
100  
6) Cyan  
Cyan color intensity 0% - 100%  
0..255  
0..255  
0..255  
0..15  
00..FF 0..100  
00..FF 0..100  
00..FF 0..100  
7) Magenta Magenta color intensity 0% - 100%  
8) Yellow  
9) Shutter  
Yellow color intensity 0% - 100%  
Shutter closed  
00..0F  
0..6  
Random Strobe (different pattern)  
Strobe Pulse effect , slow - fast  
16..31  
32..47  
10..1F 7..11,9  
20..2F 12..12,  
9
min. frequency 0,7 Hz  
max. frequency 10 Hz  
Strobe effect , slow - fast  
48..239 30..EF 13..93  
Elation Lighting  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Channel  
Function  
Time and Value  
DMX  
HEX  
%
Shutter open  
240..25 F0..FF 94..100  
5
Lamp ON (ignition)  
254..25 FE..FF 99..100  
5
10) Dimmer Dimmer closed (0%)  
0..3  
0..3  
0..1  
Dimmer 1%...99%  
movement time 0,3  
Sek.  
4..251  
4..FB  
2..98  
Dimmer open (100%)  
252..25 FC..FF 99..100  
5
11) Beam-  
shape  
Open  
Shaper  
Frost  
0..15  
16..239 10..EF  
240..25 F0..FF 95..100  
5
0..0F  
0..5  
6..94  
12) Zoom  
13) Special No function  
Audio CMY chaser slow  
Zoom 0% - 100%  
8° - 22°  
0..255  
0..15  
16..23  
24..31  
32..63  
64..79  
00..FF 0..100  
00..0F  
10..17  
0..6  
7..9  
Audio CMY chaser fast  
Rotating color chaser  
Color chaser C / C+1  
slow – fast  
18..1F 10..12  
20..3F 13..24  
40..4F 25..31  
Color chaser C / C+2  
slow – fast  
80..95  
50..5F 32..37  
PAN/Tilt chaser slow  
PAN/Tilt chaser fast  
96..111 60..6F 38..43  
112..12 70..7F 44..50  
7
Lamp OFF  
(only if shutter is closed)!  
230..24 E6..F9 92..97  
9
Reset  
250..25 FA..FF 98..100  
5
14) Move-  
ment  
No movement  
Movement  
PAN  
0
00  
0
Size  
1
1
1
1
2
2
2
2
3
3
3
3
4
4
4
4
Phase  
0°  
01..01  
02..03  
04..05  
06..07  
08..09  
10..11 0A..0B  
12..13 0C..0D  
14..15 0E..0F  
16..17  
18..19  
20..21  
22..23  
24..25  
26..27 1A..1B  
28..29 1C..1D  
30..31 1E..1F  
01..01  
02..03  
04..05  
06..07  
08..09  
0,5  
1,0  
1,7  
2,5  
3,3  
4,1  
4,9  
5,7  
6,5  
7,3  
8,0  
8,8  
9,6  
10,4  
11,2  
12  
90°  
180°  
270°  
0°  
PAN  
PAN  
PAN  
90°  
180°  
270°  
0°  
11..11  
12..13  
14..15  
16..17  
18..19  
90°  
180°  
270°  
0°  
90°  
180°  
270°  
TILT  
PAN / TILT  
PAN / TILT (inverse)  
Circle  
size / phase see also PAN  
size / phase see also PAN  
size / phase see also PAN  
size / phase see also PAN  
32..63  
64..95  
20..3F 13..25  
40..5F 26..37  
96..127 60..7F 38..50  
128..15 80..9F 51..62  
9
Circle (inverse)  
size / phase see also PAN  
160..19 A0..BF 63..75  
1
Elation Lighting  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Channel  
Function  
Time and Value  
size / phase see also PAN  
DMX  
HEX  
%
lying eight  
192..22 C0..DF 76..87  
3
random movement  
size see also PAN  
224..25 E0..FF 88..100  
5
15) Speed  
Pan/Tilt  
Pan/Tilt relative movement  
Pan/Tilt slow – fast  
0..01  
00..01  
0..1  
Pan Min. 530° = 200 s 02..255 02..FF 2..100  
Use this channel 14) also for the Pan Max. 530° = 2.65  
speed of the movements (channel s  
13).  
Tilt Min. 285° = 110 s  
Tilt Max. 285° = 1.8 s  
Lampe ON Shutter open  
Channel 9 ( min. 3 sec. ) (only if  
254..25 FE..FF 99..100  
5
230..24 E6..F9 92..97  
9
Lampe OFF  
shutter is closed, channel 9 = 0 ..15)  
*) Set the function “FCOL” ‘ON’ if you want to control the color wheel continuously.  
5 Change the Lamp  
For a frictionless operation pleas read this chapter carefully and follow all instructions.  
5.1 Safety Regulations  
Pull out the main plug!  
Wait min. 20 minutes after the last operation to cool down the fixture.  
Don’t touch the bulb of the lamp with bare fingers (this can cause damages).  
POWER WASH 575E  
Before you put the POWER WASH 575E into operation close the casing,  
otherwise your retina can be hurt!  
5.2 Realize the Lamp Change  
1. Pull out the main plug!  
2. The lamp can be changed in a very comfortable way directly from the  
backside of the case without opening the head.  
3. Open the four recessed head screws (1, 2, 3 and 4) of the backside lamp  
sheet and remove it carefully.  
4. Remove the old or broken lamp by opening the two sidewise lamp screws.  
Attention: The glass bulb of the lamp can splinter. For that reason remove  
the lamp with safety gloves or some cloth.  
5. Put in the new lamp securely with a tight fit into the socket and close the two  
Elation Lighting  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
lamp screws. The lamp filler neck must not in the direction lamp or lenses.  
Attention: Use only the original lamp type!  
6. Pull the lamp holder safely back in the shaft and close the four screws.  
7. The running time of the lamp LA1 can be reseed in the Time Menu.  
6
POWER WASH 575E  
6 Maintenance and Cleaning the POWER WASH 575E  
It is absolutely essential that the fixture is kept clean and that dust, dirt and smoke-  
fluid residues must not built up on or within the fixture. Otherwise the fixture's light-  
output will be significantly reduced. Regular cleaning will not only ensure the  
maximum light-output, but will also allow the fixture to function reliable throughout its  
life.  
A soft lint-free cloth moistened with any good glass cleaning fluid is recom-  
mended, under no circumstances should alcohol or solvents be used!  
The inside optical system should be maintained only by authorized persons. Please  
contact your local dealer.  
6.1 Safety Regulations  
Pull out the main plug!  
Wait min. 20 minutes after the last operation to cool down the fixture.  
POWER WASH 575E  
Before you put the POWER WASH 575E into operation close the casing,  
otherwise your retina can be hurt!  
6.2 Circumference and Interval (rule-of-thumb)  
The contamination of the fixture depends on the environment details. Therefore  
no general guidelines can be given. From this it follows that the intervals are only  
suggestions from our practice experience.  
Position  
Interval  
In this way  
Outside optic  
Color filter  
Beam shape  
Dimmer/Shutter  
Fan and air channel  
Reflector  
weekly  
monthly  
monthly  
yearly  
monthly  
never  
never  
soft cloth and glass cleaning fluid  
soft cloth and glass cleaning fluid  
soft cloth and glass cleaning fluid  
vacuum cleaner, airbrush, etc.  
vacuum cleaner, airbrush, etc.  
Lamp  
Elation Lighting  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Moveable parts  
yearly  
suitable fatty oil  
Attention:  
Never let optical parts come into contact with oil or fat.  
Before running the fixture wait until all parts are dried up.  
6.3 Cleaning the Optical System  
1. Pull out the main plug!  
2. Wait min. 20 minutes after the last operation to cool down the fixture.  
3. Open the upper shell of the head casing by loosening the 4 Phillips screws.  
Two on the front side and two on the back side of the head.  
4. Do the work as explained in the list above.  
POWER WASH 575E  
5. Before you put the POWER WASH 575E into operation close the casing,  
otherwise your retina can be hurt!  
7 Technical Specification  
Power supply  
Power consumption  
~90 - 260V, 50 - 60 Hz  
780 Watt, 3.8A, electronic ballast, (blind current compensated)  
Lamp: T 5A, 250V, 5x20 mm (fine-wire fuse)  
Electronic: T 1A, 250V, 5x20 mm (fine-wire fuse)  
Fuse protection  
Lamp  
Type  
Live time  
HTI 575-DE (OSRAM)  
500h (750h)  
Color temperature  
luminous flux  
Optical system  
Glass reflector  
Fresnell lens 150mm  
Color  
5600k or 7500k  
43.000 lm  
9 dichroic filter plus white plus 1x CTC 5600k, 1x CTC 3300k  
Beam shape  
Stepless Beam shape  
Frost filter  
Motor driven focus from near to far away  
Zoom: Motor driven variable angle of reflected beam from 8° to 22°  
Shutter / Strobe / Dimmer  
Strobe- effect with variable speed 1 - 10 flashes per second  
Continuously mechanical dimmer 0 - 100%  
Drive  
Elation Lighting  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Standard DMX-512, 3 pole XLR; [+] = Pin 3 [-] = Pin 2 [Ground] = Pin 1.  
The DMX- addressing starts at the DMX- address [001].  
Pan / Tilt  
Pan- movement  
Tilt- movement  
530° in max. 2,65 seconds, 16 bit resolution  
280° in max. 1,68 seconds, 16 bit resolution  
Weights and measures  
Width of the base  
Length of the base  
380 mm  
390 mm  
height (head vertical) 520 mm  
Weight (net)  
19 kg  
Elation Lighting  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 YEAR (730 DAYS) LIMITED WARRANTY  
A. Elation Professionals® hereby warrants, to the original purchaser, Elation  
Professionals® products to be free of manufacturing defects in material and  
workmanship for a period of two years (730 days) from the date of purchase. This  
warranty shall be valid only if the product is purchased within the United States of  
America, including possessions and territories. It is the owner’s responsibility to  
establish the date and place of purchase by acceptable evidence, at the time service is  
sought.  
B. For warranty service, send the product only to the Elation Professionals® factory.  
All shipping charges must be pre-paid. If the requested repairs or service (including  
parts replacement) are within the terms of this warranty, Elation Professionals® will  
pay return shipping charges only to a designated point within the United States. If the  
entire instrument is sent, it must be shipped in its original package. No accessories  
should be shipped with the product. If any accessories are shipped with the product,  
Elation Professionals® shall have no liability whatsoever for loss of or damage to any  
such accessories, or for the safe return thereof.  
C. This warranty is void if the serial number has been altered or removed; if the  
product is modified in any manner which Elation Professionals® concludes, after  
inspection, affects the reliability of the product; if the product has been repaired or  
serviced by anyone other than the Elation Professionals® factory unless prior written  
authorization was issued to purchaser by Elation Professionals®; if the product is  
damaged because not properly maintained as set forth in the instruction manual.  
D. This is not a service contract, and this warranty does not include maintenance,  
cleaning or periodic check-up. During the period specified above, Elation  
Professionals® will replace defective parts at its expense, and will absorb all  
expenses for warranty service and repair labor by reason of defects in material or  
workmanship. The sole responsibility of Elation Professionals® under this warranty  
shall be limited to the repair of the product, or replacement thereof, including parts, at  
the sole discretion of Elation Professionals®. All products covered by this warranty  
were manufactured after January 1, 1990, and bare identifying marks to that effect.  
E. Elation Professionals® reserves the right to make changes in design and/or  
improvements upon its products without any obligation to include these changes in  
any products theretofore manufactured.  
Elation Lighting  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
F. No warranty, whether expressed or implied, is given or made with respect to any  
accessory supplied with products described above. Except to the extent prohibited by  
applicable law, all implied warranties made by Elation Professionals® in connection  
with this product, including warranties of merchantability or fitness, are limited in  
duration to the warranty period set forth above. And no warranties, whether expressed  
or implied, including warranties of merchantability or fitness, shall apply to this  
product after said period has expired. The consumer’s and or Dealer’s sole remedy  
shall be such repair or replacement as is expressly provided above; and under no  
circumstances shall Elation Professionals® be liable for any loss or damage, direct or  
consequential, arising out of the use of, or inability to use, this product.  
G. This warranty is the only written warranty applicable to Elation Professionals®  
products and supersedes all prior warranties and written descriptions of warranty  
terms and conditions heretofore published.  
H. Lamps are not covered under this or any other warranty either written or implied.  
Elation Lighting  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8 Index  
A
M
Audio.......................................................... 11  
Maintenance.............................................. 21  
Measures.................................................... 23  
Mounting...................................................... 7  
B
BGV C1........................................................ 7  
P
C
Pan- movement .......................................... 23  
Power supply................................................ 9  
Circumference............................................. 22  
Cleaning..................................................... 22  
S
D
Safety Instructions...................................... 6  
Secure......................................................... 8  
Description of Device.................................. 5  
DIN VDE 0711-217....................................... 7  
Display........................................................ 15  
DMX ............................................................. 9  
DMX- Adresse............................................ 11  
T
Test Program.............................................. 11  
Tilt- movement ............................................ 23  
E
V
Error Messages......................................... 18  
VBG 70 ........................................................ 7  
F
W
Fan............................................................. 15  
Weights ...................................................... 23  
Fuse............................................................. 9  
I
Injury of the retina......................................... 6  
Invert.......................................................... 13  
Elation Lighting  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Elation Professional  
4295 Charter Street  
Los Angeles, CA. 90058  
323-582-3322 / 323-582-3108 fax  
Elation Lighting  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Earthquake Sound Speaker HoLeeS 12 User Manual
Electro Voice Speaker EVH 1152D 66 User Manual
Everpure Water System 7TO BW User Manual
Everpure Water System EV3034 83 User Manual
EVGA Computer Hardware 132 LF E655 KR User Manual
Extron electronic Switch System 5 IP Series User Manual
Freedom9 Switch IP 800 User Manual
Gefen Network Card TSE100 User Manual
GE Refrigerator 16 User Manual
Goodman Mfg Air Conditioner GPC15 SEER User Manual