INTRODUCTION:  
Thank you for having chosen this professional moving head.  
You will see you have acquired a powerful and versatile device.  
Unpack the device. Inside the box you should find:  
1. One XLR connection cable  
2. Two omega clamps  
3. One safety rope  
4. Manual  
Please check carefully that there is no damage caused by transportation. Should there be any,  
consult your dealer and don’t install this device.  
Features  
·Lamp: Philips PLATINUM 5R  
·3 DMX Channels mode: 11/13/16 channels  
·Stand alone operation with Master/Slave function, sound activated via built in microphone.  
·Pan and tilt movement: 8 and 16 bit resolution  
For smooth and precise motion  
Movement: Pan: 360°/540°optional, Tilt: 270°  
Speed of pan/tilt movement adjustable  
Scan position memory, auto reposition after unexpected movement  
·Colors: Basic color wheel with 12 dichroic mirrors, plus white, two direction rainbow effect.  
·Rotating gobo: 8 rotating gobos plus open, all gobos can be easily replaceable and gobo  
indexing  
·Prism and prism rotating , with 16 prism macros  
·Linear dimmer in precise speed from 0% ~ 100%  
2
XM485-V1.0-NR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
·Stepless frost, 0%~100% linear change frost  
·Strobe/shutter: High speed shutter, 0-13 Hz or random strobe  
·Control board with full color LCD graphic display and touch-keyboard  
·Auto-program: 7 pre-built programs can be selected.  
·Software-upload by optional accessory via DMX line  
Overview  
1) Lens  
2) Display  
3) DC Switch  
4) Microphone  
5) Left-button  
6) Down-button  
7) Right-button  
8) Mode/Esc-button  
9) Up-button  
10)ENTER-button  
11)Handle  
12)Lamp bracketrear metal panel  
13)3-Pin DMX in  
14)3-Pin DMX out  
15)5-Pin DMX in  
16)5-Pin DMX out  
17)Power supply  
18)Fuse  
SAFETY INSTRUCTIONS  
3
XM485-V1.0-NR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
This device has left the factory in perfect condition. In order to maintain this condition and to  
ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and  
warning notes written in this user manual.  
Important:  
Damages caused by the disregard of this user manual are not subject to warranty. The  
dealer will not accept liability for any resulting defects or problems.  
If the device has been exposed to temperature changes due to environmental changes, do not  
switch it on immediately. The arising condensation could damage the device. Leave the device  
switched off until it has reached room temperature.  
This device falls under protection-class I. Therefore it is essential that the device be earthed.  
The electric connection must carry out by qualified person.  
Make sure that the available voltage is not higher than stated at the end of this manual.  
Make sure the power cord is never crimped or damaged by sharp edges. If this would be the case,  
replacement of the cable must be done by an authorized dealer.  
Always disconnect from the mains, when the device is not in use or before cleaning it. Only  
handle the power cord by the plug. Never pull out the plug by tugging the power cord.  
During initial start-up some smoke or smell may arise. This is a normal process and does not  
necessarily mean that the device is defective, it should decrease gradually.  
Please don't project the beam onto combustible substances.  
If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced  
by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.  
Please be aware that damages caused by manual modifications to the device are not subject  
to warranty. Keep away from children and non-professionals.  
4
XM485-V1.0-NR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GENERAL GUIDELINES  
This device is a lighting effect for professional use on stages, in discotheques, theatres, etc., the  
device was designed for indoor use only.  
This fixture is only allowed to be operated with the max alternating current which stated in the  
technical specifications in the last page of this manual.  
Lighting effects are not designed for permanent operation. Consistent operation breaks may  
ensure that the device will serve you for a long time without defects.  
Do not shake the device.Avoid brute force when installing or operating the device.  
While choosing the installation-spot, please make sure that the device is not exposed to extreme  
heat, moisture or dust. Please don't project the beam onto combustible substances.The minimum  
distance between light-output from the projector and the illuminated surface must be more than 5  
meter.  
If you use the quick lock cam in hanging up the fixture, please make sure the quick lock fasteners  
turned in the quick lock holes correctly.  
Operate the device only after having familiarized with its functions. Do not permit operation by  
persons not qualified for operating the device. Most damages are the result of unprofessional  
operation.  
Please use the original packaging if the device is to be transported.  
For safety reasons, please be aware that all modifications on the device are forbidden.  
If this device will be operated in any way different to the one described in this manual, the  
product may suffer damages and the guarantee becomes void. Furthermore, any other operation  
may lead to short-circuit, burns, electric shock, lamp explosion, crash, etc.  
INSTALLATION INSTRUCTIONS  
a) Installing or replacing the lamp  
5
XM485-V1.0-NR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Before replacing the lamp let the lamp cool down, because during operation, the lamp can  
reach very high temperature.  
During the installation of halogen lamps do not touch the glass bulbs bare handed. Always use a  
cloth to handle the lamps during insertion and removal.  
Do not install lamps with a higher wattage. They generate higher temperatures than which the  
device was designed for.  
For the installation, you need one: PLATINUM 5R  
Procedures:  
1) Unscrew the 2 screws (A, B) on the bottom of the housing, holding the plate where the lamp  
is underneath. Carefully remove the metal plate.  
2) Insert the lamp counter-clockwise 35 degree into the lampholder, then turn clockwise 35  
degree to put it into the right position. Attention: please wrap the lamp with the soft cloth that  
comes with the packing, avoid naked hand contact to the lamp directly.  
3) Put the lampholder back position after install the lamp, tighten the screw and complete the  
installation.  
Please remember the lamp is not a hot-restrike type, you must wait for approximately 10  
minutes after having turned off the lamp before you can turn it back on again.  
b) Mounting the device  
The applicable temperature for the lighting is between -25°C to 45°C. Do not use the lighting  
under or above the temperature.  
The installation of the effect has to be built and constructed in a way that it can hold 10 times the  
6
XM485-V1.0-NR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
weight for 1 hour without any harming deformation.  
The installation must always be secured with a secondary safety attachment, e.g. an appropriate  
safety rope.  
Never stand directly below the device when mounting, removing or servicing the fixture.  
The operator has to make sure the safety relating and machine technical installations are  
approved by an expert before taking the device into operation for the first time.  
These installations have to be approved by a skilled person once a year.  
Overhead mounting requires extensive experience, including amongst others calculating  
working load limits, installation material being used, and periodic safety inspection of all  
installation material and the device. If you lack these qualifications, do not attempt the  
installation yourself. Improper installation can result in bodily injury.  
Before mounting make sure that the installation area can hold a minimum point load of 10 times  
the device’s weight.  
Connect the fixture to the mains with the power plug.  
7
XM485-V1.0-NR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation via the Omega holders  
a) Fixed the clamp on the bracket by tighten up the M12 screw on the bracket to the Ф13 hole in  
the middle of the bracket.  
b) Insert the quick-lock fasteners of the first Omega holder into the respective holes on the  
bottom of the device. Tighten the quick-lock fasteners fully clockwise.  
c) Install the second Omega holder.  
d) Pull the safety-rope through the holes on the bottom of the base and over the trussing system  
or a safe fixation spot. Insert the end in the carabine and tighten the safety screw.  
Notice: this step is quite important to ensure that the fixture will not drop out by the  
damage of the clamp.  
DMX-512 control connection  
Connect the provided XLR cable to the female 3-pin XLR output of your controller and the other  
side to the male 3-pin XLR input of the moving head. You can chain multiple  
Moving head together through serial linking. The cable needed should be two core, screened  
cable with XLR input and output connectors. Please refer to the diagram below.  
8
XM485-V1.0-NR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Address 1  
Address 14  
Address27  
DMX-512 connection with DMX terminator  
For installations where the DMX cable has to run a long distance or is in an electrically noisy environment,  
such as in a discotheque, it is recommended to use a DMX terminator. This helps in preventing corruption of  
the digital control signal by electrical noise. The DMX terminator is simply an XLR plug with a 120 Ω resistor  
connected between pins 2 and 3,which is then plugged into the output XLR socket of the last fixture in the  
chain. Please see illustrations below.  
Projector DMX start address selection  
All fixtures should be given a DMX starting address when using a DMX signal, so that the correct fixture  
responds to the correct control signals. This digital starting address is the channel number from which the  
fixture starts to “listen” to the digital control information sent out from the DMX controller. The allocation of  
this starting address is achieved by setting the correct number on the display located on the base of the device.  
You can set the same starting address for all fixtures or a group of fixtures, or make different address for each  
fixture individually.  
If you set the same address, all the units will start to “listen” to the same control signal from the same channel  
number. In other words, changing the settings of one channel will affect all the fixtures simultaneously.  
If you set a different address, each unit will start to “listen” to the channel number you have set, based on the  
quantity of control channels of the unit. That means changing the settings of one channel will affect only the  
selected fixture.  
In the case of the wash head, which is a 13 channel fixture, you should set the starting address of the first unit  
9
XM485-V1.0-NR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
to 1, the second unit to 14(13 + 1), the third to 27 (13 + 14), and so on.  
Control Board  
The Control Board offers several features: you can simply set the starting address , run the pre-programmed  
program or make a reset.  
The main menu is accessed by pressing the  
menu by pressing the -button ,  
order to select the desired menu. You can change the selection by pressing the the  
button , -button or -button. Confirm every selection by pressing the  
every mode by pressing the -button. The functions provided are described in the following sections. it  
-button until the display starts flashing. Browse through the  
-button , -button or -button. Press the Enter-button in  
-button ,  
-button. You can leave  
-
will exit from flash 10 seconds after the last keypress. Press this key under edit mode, . The functions provided  
are described in the following sections.  
To access the display menu via the internal battery, press the DC switch button for 2seconds; To shut off  
the display immediately, choose the commend " Reset All" menu and press "Enter" button, otherwise,  
the display will automatically switch off about 1 minute from last button press.  
Fun Set Dmx Address  
ctio Value Display  
n Set To Slave  
A001~AXXX  
PAN……  
DMX address setting  
DMX value display  
Slave setting  
Slave1,Slave2,Slave3  
Master / Alone  
Master / Alone  
Mo Auto Program  
de Music Control  
Auto program  
Music control  
Time Information Current Time  
Total Life Hours  
Last Run Hours  
XXXX(Hours)  
XXXX(Hours)  
XXXX(Hours)  
XXXX(Hours)  
XXXX(Minute)  
Password=XXX  
ON/OFF  
Power on running time  
Fixture running time  
Fixture Last times clear  
Lamp running time  
Lamp off time  
Lamp Hours  
Lamp Off Time  
Info  
rma  
tion  
Timer Password  
Timer Password 038  
Clear Fixture Last time  
Lamp Password Code=”038”  
Clear lamp time  
Clear Last Run  
L-Timer Password  
Clear Lamp Time  
Password=XXX  
ON/OFF  
10  
XM485-V1.0-NR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Temperature Info Head Temperature  
XXX/℉  
Temperature in the head  
Software version of each IC  
Lamp on/off  
Software Version Ver1.0……  
Lamp On or Off  
La Automatic La-On  
mp Lamp On Via DMX  
ON/OFF  
ON/OFF  
ON/OFF  
Lamp on/off when Power on  
Lamp on via DMX  
Con Lamp Off Via DMX ON/OFF  
Lamp off via DMX  
Lamp restart at temp.  
Lamp off at temp.  
trol Lamp On at Temp.  
Lamp Off at Temp.  
Status Settings  
20~79,55/68~174131℉  
80~139, 130/176~282, 266℉  
Address via DMX  
No DMX Status  
Pan Reverse  
ON/OFF  
Add. via DMX  
Close/Hold/Auto/Music  
ON/OFF  
Auto run if no DMX  
Pan Reverse movement  
Tilt Reverse movement  
Pan Degree Select  
Tilt Reverse  
ON/OFF  
Pan Degree  
630/540  
Feedback  
ON/OFF  
Movement Feedback switch  
Movement Mode Select  
Sensitivity of Mic.  
Movement Speed  
Mic Sensitivity  
Hibernation  
Speed 1~ 4  
0~99%  
Per  
OFF, 01M~99M15M  
Stand by Mode  
son  
Fans Control  
Auto Fans Speed  
High Fans Speed  
Low Fans Speed  
Shutoff Time  
Display Reverse  
Key Lock  
Fans Speed Mode Select  
alit  
y
02~60m 05m  
ON/OFF  
ON/OFF  
Display Setting  
Temperature C/F  
Display shutoff time  
Display Reverse 180 degree  
Key Lock  
Celsius/ Fahrenheit  
Temperature switch between  
/℉  
Initial Effect  
Reset Default  
Reset All  
PAN =XXX  
ON/OFF  
Initial effect position  
Restore factory set.  
Reset all motors  
Res  
Reset Pan&Tilt  
Reset Pan/Tilt  
et  
Reset Colors  
Reset color wheel  
Reset gobos  
Fun  
Reset Gobos  
ctio  
Reset Shutter  
Reset shutter and/or dimmer  
Reset other motors  
n
Reset Others  
Test Channel  
PAN ……  
Test function  
Manual Control  
PAN =XXX  
:
Fine adjustment of the lamp  
Effe  
ct  
Adj Calibrate Values  
ust  
Calibrate Password  
Color wheel=XXX  
:
Standard Mode  
Basic Mode  
Extended Mode  
User Mode A  
User Mode B  
User Mode C  
Password “050”  
Calbrate and adjust the effects  
to standard/right position  
User’s mode to change  
channel numbers  
User Mode  
Use  
rs  
Mo  
de  
11  
XM485-V1.0-NR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Edit User Mode  
Select Programs  
Edit Program  
Edit Scenes  
Max Channel = XX  
Preset User modes  
Set  
PAN = CH01  
:
Auto Pro Part 1 = Program 1 ~ 10 Program 1  
Auto Pro Part 2 = Program 1 ~ 10 Program 2  
Auto Pro Part 3 = Program 1 ~ 10 Program 3  
Select programs to be run  
Program 1  
:
Program Test  
Testing program  
Edit  
Pro  
gra  
m
Step 01=SCxxx  
Step 64=SCxxx  
Program in loop  
Program 10  
Save and exit  
Edit Scene 001 Pan,Tilt,……  
~ Edit Scene--Fade Time--  
Save and automatically return  
manual scenes edit  
250  
--Secne Time--  
Input By Outside  
Rec. Controller  
XX~XX  
Automat. scenes rec  
Main Menu Functions  
Main functions:  
Function Mode:  
“Set DMX Address” - DMX address setting – This function is used to set or adjust  
the fixture’s starting DMX address. Every device controlled by DMX has to have a  
unique starting address. The addressing feature is what allows DMX to function  
properly. The DMX address of a fixture is what allows it to communicate with a  
controller properly. The DMX addressing also allows the fixture to ignore any DMX  
information coming from the controller that is not meant specifically for the fixture.  
Because each fixture is connected in a daisy-chain fashion it is imperative to assign  
a proper and unique starting DMX address to each and every fixture. The DMX  
address is non-destructive and will remain in the fixture’s memory even when the  
power to the unit is switched off. Memory is backed-up and retain by an internal  
power source that should last about five years. For proper DMX addressing see  
Section 10/Page 35 of this user manual.  
“Value Display” - Display the DMX 512 value of each channel  
With this function you can display the DMX 512 value of each channel. The display  
will automatically detail the changing DMX values as they are received from the  
controller.  
“Set to Slave” - Slave setting for Master/Slave Operation  
With this function, you can define the device as slave for operation in Master/Slave  
12  
XM485-V1.0-NR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
mode. Each slave setting will have a different function for a dynamic lightshow  
without a controller.  
Auto Program  
This function allows the internal programs to run in either stand-alone or master/  
salve mode. In “Master” mode the fixture will send DMX data to other fixtures  
connect via the DMX chain. In “Alone” mode the fixture will operate as a single  
fixture. The program for this mode is selected in the “Select program” section of  
the control menu. You can set the number of steps under “Edit program”. You can  
edit the individual scenes under “Edit scenes”. With this function, you can run the  
individual scenes either automatically, i.e. with the adjusted Step-Time.  
Music control  
This function is similar to the “Auto Program” described in the previous section with  
the exception that this function will advance the built-in program via sound.  
Information:  
Time information  
These functions will detail different time functions associated with the fixture.  
Current Time  
This function displays the running time of the fixture from the last power on. The  
display shows “XXXX”, where “XXXX” represents the number of hours the fixture  
has been running. This counter is automatically reset after every power-on.  
Total Run Time  
This function tracks the total running time of the fixture from the very first start-  
up. Where “XXXX ”represents the total number of running hours. This time is  
none destructive and will remain in the fixtures memory indefinitely.  
Last Run Hours  
This function tracks a cycle run time. Use this function to keep track of rental  
period, or to note the time from the last service. This setting can be reset at any  
time.  
“L-Timer Password.”  
Lamp Hours. This function tracks the total number of lamp running hours. Where  
“XXXX” represents the number of hours the lamp has been running. This  
13  
XM485-V1.0-NR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
counter should be reset after every lamp change.  
Lamp Off Time  
This function displays the running time of the lamp from the last power on. The  
display shows “XXXX”, where “XXXX” represents the number of hours the lamp  
has been running since it was last struck. This counter is automatically reset  
after every power-on.  
Timer Password  
Use this function to enter the “Clear Last Run” password. Password is “038”  
Clear Last Run  
This function will allow the “Last Run Hours” function be cleared and reset.  
L-Timer Password  
Use this function to enter the “Clear Lamp Time” password. Password is “038”  
Clear Lamp Time  
This function resets the lamp “ON” time to zero. Please reset the lamp “ON” time  
at every lamp replacement. This procedure tracks the lamp running time so the  
lamp can be replaced at the end of it’s recommended duty cycle.  
• Select “Clear lamp time” in the system menu.  
• The LCD will display “ON” or “OFF.” Were “ON” will reset the lamp time.  
• Press enter to confirm.  
• Press the Mode/Esc-button to return to the main menu.  
Temperature Info.  
This function will detail the internal head temperature in either Celsius or  
Fahrenheit.  
Software version  
This function will display the current operating software version of the fixture.  
• The LCD will read “V-X.X”, “X.X” represents the version number, e.g. “V-1.0”,  
“V-2.6”.  
• Use the UP and DOWN buttons to toggle through the software version of  
different IC’s.  
14  
XM485-V1.0-NR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Lamp Control:  
Lamp On or Off  
This function allows manual control of the lamp power via the on-board system  
menu.  
• Select “ON” if you wish to strike the lamp or “OFF” to switch it off.  
• Press “ENTER” to confirm.  
• Press the Mode/Esc-button to return to the main menu.  
Automatic La-On  
When in the “ON” position, this function will automatically turn the lamp on when  
power is applied to the fixture  
Lamp On Via DMX  
When engaged, this function will allow the lamp to be switched “on” via a DMX  
controller. Select “ON” to enable this function or “OFF” to disable it.  
Lamp Off Via DMX  
When engaged, this function will allow the lamp to be switched “off” via a DMX  
controller. Select “ON” to enable this function or “OFF” to disable it.  
Lamp On at Temp.  
The fixture is designed to shut the lamp off when an excessive temperature is  
sensed inside the head by the on-board CPU. The lamp is shut down to prevent  
damage to the lamp and avoids possible internal damage to the head. This function  
sets the minimum temperature for lamp restrike after the lamp has been  
automatically shut off.  
Lamp Off at Temp.  
The fixture is designed to shut the lamp off when an excessive temperature is  
sensed  
inside the head by the on-board CPU. The lamp is shut down to prevent  
damage to the lamp and avoids possible internal damage to the head. This function  
sets the maximum internal operating temperature of the head before the lamp will  
automatically be shut down. This function can be set to activate at an internal  
temperature between 80° C and 139° C. Inside temperatures below 90° C are not  
critical. Temperatures above 90° C should lead to the lamp being switched off.  
Please note that the outside temperature should not exceed 45° C.  
15  
XM485-V1.0-NR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Personality:  
Status setting  
Address via DMX - This function allows the DMX address to remotely be  
adjusted from a DMX console. This setting requires special settings for both the  
controller and the fixture. RDMX is on by default. For operational instructions  
please see Section 10/Page 35 of this manual “Remote DMX addressing.”  
No DMX Status – This function dictates how the fixture will function if it looses  
DMX signal during normal operation. The default function is set to hold, in which  
the fixture will lock into the last DMX signal it received and remain in that  
position until it is turned off or begins receiving a new DMX signal. If the fixture is  
turned on without any DMX signal, the fixture will automatically go in to sound-  
active mode. Available settings are: “Close” – Shutter flags will close. “Hold” –  
Fixture will remain at it’s last settings. “Auto” – Fixture will go into stand-alone  
mode, running the built-in program. “Music” – The fixture will go into sound-  
active mode.  
Pan Reverse - This function allows you to invert all pan movements. Use the Up  
and Down buttons to turn this function On or Off. Press the Enter button to  
accept the change or the Mode button to cancel and return to the main menu.  
This function is “OFF” by default.  
Tilt Reverse - This function allows you to invert all tilt movements. Use the Up  
and Down buttons to turn this function On or Off. Press the Enter button to  
accept the change or the Mode button to cancel and return to the main menu.  
This function is “OFF” by default.  
Pan Degree – This function changes the maximum Pan resolution from either  
540˚ or 630˚. The default function is 540˚. 630˚ operation allows for greater  
coverage, but slower pan movement.  
Feedback – This function turns the feedback correction on or off. This function  
is set to “ON” as default. This function allows for automatic pan and tilt correction  
in the event either one disrupted during normal operation.  
Movement Speed – This function changes the speed function of the Pan and  
Tilt motors. Use this function intergrading Platinum Spot 5R into lighting rigs that  
16  
XM485-V1.0-NR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
includes original Design Spot 250s. There are 3 different mode variations;  
Speed 1 (Default): Slower than the original Design Spot 250 for smoother,  
more precise movements.  
Speed 2: Pan and Tilt speeds are identical to the first generation Design  
Spot  
250.  
Speed 3: includes a faster Pan speed. Pan speed is 0.5 seconds faster than  
original DS-250. Tilt speed will be the same as speed 2.  
Mic Sensitivity – This function makes the internal microphone more or less  
sensitive to sound. This function only works in conjunction with the sound active  
modes. The default setting is 70% and setting range from 0% to 99%.  
Hibernation – When activated, this function will automatically put the fixture in  
power stand-by mode after a defined period of time of no DMX activity. This  
prevents the fixture form expending power for extended periods in the event the  
fixture has been left on accidently. In stand-by mode the lamp and all motors will  
power down if no DMX signal is sent to the fixture for a period of 15 minutes  
(default, can be user defined). The fixture will automatically reset and return to  
normal operation once a DMX signal is sensed.  
Fans Control - This function is used to change the functionality of the internal  
cooling fans. The available selections are: 1) “AUTO” – The fans will automatically  
switch between low and high speeds depending on the internal operating  
temperature. 2) “HIGH” – The fans will run in high-speed mode regardless of  
operating temperature. 3) “LOW” – The fans will remain in low speeds regardless of  
internal operating temperature.  
Display Settings  
Shutoff Time - The display is designed to turn off during normal operation to  
avoid excessive light in situations that require an extremely dark environment.  
This function will adjust the amount of time the display will remain on until it is  
automatic turned off. This function is disabled as default.  
Display Reverse – This function will allow the entire display to be flipped by  
180˚ to allow for better view when the fixture is hung from truss or a ceiling. This  
17  
XM485-V1.0-NR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
function is disabled as default.  
Key Lock – This function allows you to lock the keys on the display to prevent  
menu tampering. With this function you can activate the automatic keylock  
function. If this function is activated, the keys will be automatically locked in 15  
seconds from the last command. In order to deactivate or temporarily deactivate  
the keylock function, press the Mode/Esc Button for 3 seconds to regain access to  
the menu  
commands.  
Temperature C/F – This function changes the temperature the unit will display from  
either Celsius or Fahrenheit. Fahrenheit is set as the default measurement.  
Initial effect – This function allows a user to create and assign a custom “Home  
Position” into the fixture. Adjusting the Pan and Tilt values then locking those values  
into the fixture’s internal memory creates the new “Home” position.  
Restore Default – This function is used to restore the factory settings of the device.  
All settings will be set back to the default values (shaded). Any edited scenes will be  
lost.  
Reset Functions: The reset function returns a motor to the “Home” position. There are  
several reset functions available on this fixture. The list below details the functionality of  
each available selection.  
Reset All: This function will reset all internal motors to the home position.  
Reset Pan and Tilt: This function will only reset the pan and tilt motors to the  
home position.  
Reset Colors: This function will only reset the color wheel to the home position.  
Reset Gobos: This function will only reset the gobo wheels to the home position.  
Reset Shutter: This function will only reset the blackout shutter to the home  
position.  
Reset Others: This function will reset all other motors not associated with any in  
the previously listed reset commands to the home position.  
18  
XM485-V1.0-NR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Effect Adjust:  
Test Channel – This menu function allows the user to select each individual  
fixture channel and test it’s function independently from the control  
board.  
Lamp adjustment (manual control) – This function readies the fixture for lamp  
optimization in a simple single step procedure. This function will center the pan and tilt  
motors and at the same time open the shutter and bring the dimmer to 100%. The pan  
and tilt function will still operate if the fixture needs to be positioned to a flat clear  
surface. For more information on lamp optimization please see Section 6/Page 14.  
Calibrate values – This function should only be performed by a qualified technician.  
This function allows a user to make small adjustments to the effect wheels (color, gobo,  
shutter, etc) to compensate for ware or in the event a sensor has been knocked slightly  
out of place. Because improper use of this function can result in undesired operation this  
function has been password protected. The password is 050 and must be entered each  
time the calibration menu function is entered. Because calibration is an extremely  
delicate procedure instruction on performing this action are left out of this manual. For a  
first time calibrator, please contact our customer support team for step-by-step  
instructions.  
User Mode Set:  
User mode – This function allows the user to create user defined channel orders  
allowing the fixture to match the channel order of other fixtures on the market for easier  
operation. A total of three user modes may be configured: User Mode A, User Mode B,  
and User Mode C.  
Edit User mode – This function allows the user to make the actual changes in the user-  
defined modes that are created in the previous function.  
EDIT PROGRAM: - The fixture comes equipped with a built-in DMX recorder that allows  
custom programs to be installed and recalled directly from the fixture’s control board.  
Programs can be created and stored using the fixture’s control board or by using an  
19  
XM485-V1.0-NR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
external DMX controller. For detailed instructions on how to complete this task please  
see Section 12/ Page 39.  
Select program – This function allows the user to select one of ten of the user defined  
built-in programs. This program is then accessed in “Function Mode” under “Program  
Run.”  
Edit program – This function allows the user to edit the built-in programs.  
Edit Scenes – This function allows the user to edit or define the actual scenes that are  
stored in the user defined built-in programs that are accessed in the previous step.  
Rec Controller - The Platinum Spot 5R features an integrated DMX recorder. Pre-  
programmed scenes can be transmitted to the fixture via any DMX compliant controller.  
This function allows those scenes to be stored in to the fixture’s built-in memory and  
then subsequently used to create the user-defined programs.  
20  
XM485-V1.0-NR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTRUCTIONS ON USE:  
DMX channel´s functions and their values (16 DMX channels):  
Mode/Channel  
Value  
Function  
St Ba Ex  
 
 
 
PAN Movement 8bit :  
0-255 Pan Movement By 360/540  
Pan Fine 16bit  
0-255 Fine control of Pan movement  
TILT Movement 8bit :  
0-255 Tilt Movement By 270  
Tilt Fine 16bit  
0-255 Fine control of Tilt movement  
1
2
3
4
1
 
2
1
2
3
4
 
 
 
 
 
Color Wheel :  
0-9  
Open / white  
10-19 Color 1  
20-29 Color 2  
30-39 Color 3  
40-49 Color 4  
50-59 Color 5  
60-69 Color 6  
70-79 Color 7  
80-89 Color 8  
90-99 Color 9  
5
3
5
100-109 Color 10  
110-119 Color 11  
120-127 Color 12  
128-189 Forwards rainbow effect from fast to slow  
190-193 No rotation  
194-255 Backwards rainbow effect from slow to fast  
 
Color Wheel Fine :  
0-255 Color Wheel colour change to any position Fine  
Rotating gobos, cont. rotation :  
 
 
6
 
0-9  
Open  
10-19 Rot. gobo 1  
20-29 Rot. gobo 2  
30-39 Rot. gobo 3  
40-49 Rot. gobo 4  
50-59 Rot. gobo 5  
60-69 Rot. gobo 6  
70-79 Rot. gobo 7  
80-89 Rot. gobo 8  
90-104 Rot. gobo 1 shake  
6
4
7
105-119 Rot. gobo 2 shake  
21  
XM485-V1.0-NR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
120-134 Rot. gobo 3 shake  
135-149 Rot. gobo 4 shake  
150-164 Rot. gobo 5 shake  
165-179 Rot. gobo 6 shake  
180-194 Rot. gobo 7 shake  
195-209 Rot. gobo 8 shake  
210-255 Rot. gobo wheel cont. rotation slow to fast  
 
Rotating gobo index, rotating gobo rotation :  
0-127 Gobo indexing  
7
5
8
9
128-189 Forwards gobo rotation from fast to slow  
190-193 No rotation  
194-255 Backwards gobo rotation from slow to fast  
 
Rotating gobo indexing Fine  
0-255 Fine indexing  
 
 
 
3 facet rotating prism, Prism / Gobo macros:  
0-3  
open  
4-63 Forwards rotation from fast to slow  
64-67 No rotation  
68-127 Backwards rotation from slow to fast  
128-135 Macro 1  
136-143 Macro 2  
144-151 Macro 3  
152-159 Macro 4  
160-167 Macro 5  
168-175 Macro 6  
176-183 Macro 7  
184-191 Macro 8  
192-199 Macro 9  
200-207 Macro 10  
208-215 Macro 11  
216-223 Macro 12  
224-231 Macro 13  
232-239 Macro 14  
240-247 Macro 15  
248-255 Macro 16  
8
6
10  
 
Shutter, strobe:  
0-31 Shutter closed  
32-63 No function (shutter open)  
64-95 Strobe effect slow to fast  
96-127 No function (shutter open)  
128-159 Pulse-effect in sequences  
160-191 No function (shutter open)  
192-223 Random strobe effect slow to fast  
224-255 No function (shutter open)  
9
7
11  
22  
XM485-V1.0-NR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
 
Dimmer intensity:  
0-255 Intensity 0 to 100%  
Fine Dimmer intensity:  
0-255 Dimmer intensity fine  
Frost:  
10  
8
12  
13  
 
 
11  
9
14  
0-127 Disable frost  
128-255 Enable frost  
 
Speed Pan/Tilt movement:  
0-225 max to min speed  
12 10 15  
226-235 blackout by movement  
236-245 blackout by all wheel changing  
246-255 no function  
 
Lamp on/off, reset, internal programs:  
0-19 colour change normal  
20-29 colour change to any position  
30-39 colour & gobo change to any position  
40-59 Lamp on  
60-79 Lamp switch off  
80-84 All motor reset  
85-87  
88-90 Colors motor reset  
91-93  
94-96 Shutter & Dimmer motor reset  
97-99 Other motor reset  
Scan motor reset  
Gobo motor reset  
13 11  
16  
100-119 Internal program 1  
120-139 Internal program 2  
140-159 Internal program 3  
160-179 Internal program 4  
180-199 Internal program 5  
200-219 Internal program 6  
220-239 Internal program 7  
240-255 Auto program by music  
ERROR MESSAGE  
When you turn on the fixture, it will make a reset at first. The display may show“Err channel is XX” while  
there are problems with one or more channels. “XX” stands for channel 1, 2, 3, 4, 5, 6 who has the testing  
sensor for positioning. For example, when the display shows “Err channel is Color wheel”, it means there is  
23  
XM485-V1.0-NR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
some error in channel 1. If there are some errors on channel 1, channel 5, channel 6 at the same time, you may  
see the error message “Err channel is Color wheel”, “Err channel is Pan movement”, “Err channel is Tilt  
movement” flash repeated for 2 times, and then the fixture will generate a second reset. If the fixture remain  
error message after performing reset more than 2 times, only the channels which have errors can not work  
properly, others can work as usual. Please contact with dealer or manufacturer for service, self repair is not  
allowed.  
PAN- movement Er  
(PAN-yoke movement error) This message will appear after the reset of the fixture if the yoke’s magnetic-  
indexing circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving  
IC on the main PCB). The PAN- movement is not located in the default position after the reset.  
TILT- movement Er  
(TILT-head movement error) This message will appear after the reset of the fixture if the head’s magnetic-  
indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its  
driving IC on the main PCB). The TILT- movement is not located in the default position after the reset.  
Color wheel Er  
(Color wheel- error) This message will appear after the reset of the fixture if the magnetic-indexing circuit  
malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main  
PCB). The color wheel is not located in the default position after the reset.  
Gobo wheel 1 Er  
(Gobo wheel 1 - error) This message will appear after the reset of the fixture if the magnetic-indexing circuit  
malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main  
PCB). The Gobo wheel 1 is not located in the default position after the reset.  
Gobo Rot 1 Er  
(Gobo Rot 1- error) This message will appear after the reset of the fixture if the magnetic-indexing circuit  
malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main  
PCB). The Gobo Rot 1 is not located in the default position after the reset.  
CLEANING AND MAINTENANCE  
The following points have to be considered during the inspection:  
1) All screws for installing the devices or parts of the device have to be tightly connected and must not be  
corroded.  
2) There must not be any deformations on the housing, color lenses, fixations and installation spots (ceiling,  
suspension, trussing).  
3) Mechanically moved parts must not show any traces of wearing and must not rotate with  
unbalances.  
4) The electric power supply cables must not show any damage, material fatigue or sediments.  
Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and  
any safety problems have to be removed.  
In order to make the lights in good condition and extend the life time, we suggest a regular  
cleaning to the lights.  
1) Clean the inside and outside lens each week to avoid the weakness of the lights due to  
accumulation of dust.  
2) Clean the fan each week.  
3) To make sure the smooth gobo rotation, we suggest adding proper lube to the wheel each  
three month, avoiding the excessive lube splashes during the gobo rotating.  
4) A detailed electric check by approved electrical engineer each three month, make sure that the  
circuit contacts are in good condition, prevent the poor contact of circuit from overheating.  
24  
XM485-V1.0-NR  
Download from Www.Somanuals.com. All Manuals Search And Download.  
We recommend a frequent cleaning of the device. Please use a moist, lint- free cloth. Never use alcohol or  
solvents.  
There are no serviceable parts inside the device except for the lamp. Please refer to the instructions under  
“Installation instructions”.  
Should you need any spare parts, please order genuine parts from your local dealer.  
TECHNICAL SPECIFICATIONS  
Power supply: AC 100V-240V~, 50Hz/60Hz  
Power consumption: 350W  
Packing dimensions: 53.5 x 42 x 41 cm  
Net weight: 9.5 KGS  
Gross weight: 13 KGS  
Remark: errors and omissions for every information given in this manual excepted. All information is subject to  
change without prior notice.  
25  
XM485-V1.0-NR  
Download from Www.Somanuals.com. All Manuals Search And Download.  

EdgeStar Air Conditioner AP12005ECO User Manual
Electro Voice Speaker DMS 1122 85 User Manual
Euro Pro Carpet Cleaner EP95B User Manual
EVGA Computer Hardware 121 LF E652 KR User Manual
Extron electronic Computer Accessories HSA 822 User Manual
Extron electronic Stereo Receiver IR Link User Manual
Franke Consumer Products Cooktop FCH 906 User Manual
GE Answering Machine 2 9022 User Manual
Giant Water Pump GP7128 User Manual
Global Machinery Company Portable Generator FCG001 User Manual