		 9V BATTERY POWERED   
					Model Ei 100C Ionisation   
					High sensitivity – responds to all standard fires   
					Dual Ionization chamber - quick response fast   
					flaming fires   
					Battery powered – 9V supplied)   
					Interconnect up to 12 other alarms   
					Needs no wiring   
					Missing battery indicator   
					Low battery warning   
					Built in sounder   
					Test button   
					Kitemarked to BS EN 14604:2005   
					Product Description   
					Operation   
					The Ei100C is an Ionisation Smoke Alarm that runs on a   
					9V alkaline battery (supplied with the alarm).   
					Interconnect up to 12 other alarms (9V ionisation,   
					optical or heat) when one senses smoke, all alarm.   
					Helps ensure warning will be heard throughout the   
					house   
					The smoke detector will activate the built in sounder   
					upon sensing smoke particles   
					Ionisation smoke alarms operate on the principle that   
					electrical current flowing between electrodes in an   
					ionization chamber is reduced when smoke particles   
					enter.   
					The smoke detector will automatically reset itself   
					and silence the sounder when smoke particles are   
					no longer present in the sensing chamber   
					Ionisation technology gives a rapid response to fast   
					flaming fires   
					The Ei100C is easily installed and comes supplied with   
					all necessary screw fixings.   
					The built in sounder will provide a minimum sound   
					output of 85dB at 3m   
					The Ei100C is fitted with a warning flag that pops up   
					when the battery is removed. This prevents the cover   
					from closing when there is no battery fitted to the unit.   
					When the battery is being installed or changed, this flag   
					must be held down while gently pushing the battery into   
					the battery holder.   
					The smoke detector has a built in warning flag to   
					prevent installation of the detector without a battery   
					fitted   
					The “Test” button will perform a self test and sound   
					the horn (it may take up to 10 seconds)   
					When the battery is first connected, the alarm may sound   
					for 2-3 seconds – this is normal and means that the   
					battery is connected correctly   
					The smoke detector will emit a beep every 40   
					seconds to indicate that the battery back up is   
					depleted and needs replacing   
					Shannon Free Zone, Shannon, Co. Clare, Ireland.   
					Ph.+353 61 471277 Fx.+353 61 471053   
					Email. [email protected]   
					
					E & OE As our policy is one of continuous product development, we reserve the right to alter product details without prior notice.   
					Ei100C DataSht RevB   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 |