| Installation   Instructions   ZXR758 and ZXR7510   Recirculating Accessories   For Model ZV750, Vent Hood   M o no   g ra   m Download from Www.Somanuals.com. All Manuals Search And Download.   Installation Preparation   REQUIRED ACCESSORIES   • Order the required accessory at the same time as the   vent hood and have on site before installation.   • Each kit includes decorative duct cover, air deflector   and charcoal filters.   This book provides step by step instructions to install the   Monogram ZV750 wall mounted hood for recirculating   operation.   • One of the following accessory kits is required for   non-vented wall mounted installations of model ZV750.   Choose the correct kit according to ceiling heights:   ZXR758 – For 8 to 9 ft. ceiling height.   ZXR7510 – For 9 to 10 ft. ceiling height.   PRODUCT DIMENSIONS   The vent hood must be installed 24" min. and 30" max.   above the cooking surface. 25-1/2" is recommended for   best performance and to insure that the duct cover   meets the ceiling. The cooking surface should be at least   36” above the floor. Installation will be easier if the vent   hood is installed before the cooktop and countertop is   installed.   *Height   to Ceiling   8-1/4"   34-5/8"   21-5/8"   * ZXR758   26-1/4" for 8 ft. Ceiling   38-1/4" for 9 ft. Ceiling   ZXR7510   34-1/4" to 50-1/4" for   *25-1/2" Recommended   9 ft. to 10 ft. Ceiling   * The distance between the cooking surface and the bottom of the   hood must be at least 24” and up to 30” The 25-1/2” recommended   installation height, above the standard 36” countertop, will insure   duct cover fit to the ceiling.   36" Min.   3 Download from Www.Somanuals.com. All Manuals Search And Download.   Installation Preparation   POWER SUPPLY   DUCT COVER ACCESSORIES   A duct cover accessory is required for recirculating   operation. Use this chart to determine which   accessory is required for your ceiling height.   IMPORTANT   – (Please read carefully)   WARNING:   ZV750SY Installation Heights   Actual   FOR PERSONAL SAFETY, THIS APPLIANCE MUST   BE PROPERLY GROUNDED.   * Possible Hood   Installation Height   Ceiling   Height   Recirculating   Accessory   Remove house fuse or open circuit breaker before   beginning installation.   24-1/2″   7′ 11″   8′ 0″   8′ 1″   8′ 2″   8′ 3″   8′ 4″   8′ 5″   8′ 6″   8′ 7″   8′ 8″   8′ 9″   8′ 10″   8′ 11″   9′ 0″   9′ 1″   9′ 2″   9′ 3″   9′ 4″   9′ 5″   9′ 6″   9′ 7″   9′ 8″   9′ 9″   9′ 10″   9′ 11″   10′ 0″   25-1/2″   Do not use an extension cord or adapter plug with   this appliance. Follow National Electrical Code or   prevailing local codes and ordinances.   25-1/2″ to 26-1/2″   25-1/2″ to 27-1/2″   25-1/2″ to 28-1/2″   25-1/2″ to 29-1/2″   25-1/2″ to 30″   25-1/2″ to 30″   25-1/2″ to 30″   25-1/2″ to 30″   25-1/2″ to 30″   25-1/2″ to 30″   25-1/2″ to 30″   25-1/2″ to 30″   25-1/2″ to 30″   25-1/2″ to 30″   25-1/2″ to 30″   25-1/2″ to 30″   25-1/2″ to 30″   25-1/2″ to 30″   25-1/2″ to 30″   25-1/2″ to 30″   25-1/2″ to 30″   25-1/2″ to 30″   25-1/2″ to 30″   25-1/2″ to 30″   Electrical supply   This vent hood must be supplied with 120V, 60Hz,   and connected to an individual, properly grounded   branch circuit, and protected by a 15 or 20 amp   circuit breaker or time delay fuse.   • Wiring must be 2 wire with ground.   • If the electrical supply does not meet the above   requirements, call a licensed electrician before   proceeding.   • Route house wiring as close to the installation   location as possible. Wiring should enter at least 4"   above the bracket on the right side.   • Connect the wiring to the house wiring in   accordance with local codes.   Grounding instructions   The grounding conductor must be connected to   a ground metal, permanent wiring system, or an   equipment-grounding terminal or lead on the hood.   WARNING:   The improper connection   of the equipment-grounding conductor can result   in a risk of electric shock. Check with a qualified   electrician or service representative if you are in   doubt whether the appliance is properly grounded.   * Based on 36″ countertop height.   ZV750SY Duct Cover Dimensions   9-1/4"   Hood and   Accessory   TOOLS AND MATERIALS   REQUIRED (NOT SUPPLIED)   B A B 22-13/16″   34-5/8″   ZXR758C   18-7/8″   18-7/8″   • 10 mm Hex wrench/socket   • Safety glasses   • Tape measure   • Knife   ZXR7510C   A • Duct tape   • Spirit level   • Gloves to protect against sharp   edges   • 120V 60Hz. 15 or 20 Amp, 2 wire   with ground. Properly grounded   branch circuit.   • Strain relief for junction cover.   • 6" round duct, length to suit   installation.   • Wire cutter/stripper   • Wire nuts   • Electric drill and   appropriate bits   • Phillips and flat blade   screwdrivers   • Hammer   11-7/8"   • Pliers   • Center punch   4 Download from Www.Somanuals.com. All Manuals Search And Download.   Installation Preparation   • Locate and remove 2 screws at the top of the   REMOVE THE PACKAGING   assembly and 2 screws inside the hood behind the   filter guides on the left and right sides. Discard the   shipping board.   The vent hood is shipped secured to a shipping   board with 4 screws.   • Remove the duct cover, parts box and styrofoam   packaging.   • Lift the hood out of the box, using hand grips on   both sides of the shipping board.   Junction   Box   • Remove and properly discard the plastic wrapping.   Knockout   Mounting   Screw   Mounting   Screw   Shipping Board   • Remove junction box cover.   • Remove knockout from junction box.   • Install strain relief onto junction box.   Mounting Screw   Shipping Board   Check Installation Hardware   Locate the hardware accessory box packed with the   hood and check contents.   • Drill 1/8" Pilot Holes For Mounting Brackets.   C L 5-7/8"   26-14" to   38-1/4" to   8 9 ft. Ceiling   ft. Ceiling   3 Stainless   Steel Grease   Filters   38-1/4" to 50-1/4" For   9ft. to 10 ft. Ceiling   Using Optional Accessory   ZX10SY Duct Cover   C L 17-5/16"   C L • Drill 1/8" Pilot Holes.   • Drill 1/8" Pilot Holes.   Align edge 25-1/2" above Cooking Surface.   Wall Mount Template   10 Wood   Screws   10 Metal Wall   2 Mounting Brackets   Fasteners   Check contents of the required accessory,   ZXR758 or ZXR7510.   2 Large   Flat Washers   2 Wood   Screws   Decorative   Duct   Covers   2 Plastic   Wall Fasteners   Air Deflector with   Upper Duct   Connector   Duct Cover Bracket   (not required for   recirculating operation)   2 Phillips Head   Decorative Screws   2 Phillips Head   Decorative Screws   Recirculating   Decorative   Duct Cover   3 Charcoal Filters   2 Side Bars with 4 Machine Screws   5 Download from Www.Somanuals.com. All Manuals Search And Download.   Installation Instructions   1 DETERMINE INSTALLATION   LOCATION   To determine the exact location of the vent hood.   • Locate the template packed with the literature.   – Measure 36" from the floor to the top of the   cooking surface. Add 25-1/2" recommended   space from the cooking surface to the bottom   of hood. Mark that location.   – Use a level to draw a straight pencil line on the   wall.   – Tape the template in position along the penciled   line. CHECK TO BE SURE THE TEMPLATE IS   LEVEL.   2 INSTALL MOUNTING BRACKETS   Whenever possible, the vent hood should be secured to wall   studs.   • With the template taped in place, use a punch to   mark all mounting screw locations.   • Drill 1/8" pilot holes at the 6 punched locations.   • Remove the template.   • Enlarge holes that did not enter studs to 3/8" and   tap anchors for metal wall fasteners into the holes.   – Drive screws into the fasteners to allow anchors to   expand against the wall material. Remove the   screws for final installation.   • Secure the mounting brackets to the wall studs with   wood screws provided.   – For hollow walls, secure the mounting brackets   through the anchors.   – Measure from the peak of the hood to the ceiling   as indicated.   Ceiling   Screws   “B”   Note: Screws “A” and   Screws   “A”   “B” are pre-assembled   onto the brackets. Do   not remove these   screws.   • Drill 1/8" Pilot Holes For Mounting Brackets.   5-7/8"   26-14" to   38-1/4" to   8 9 ft. Ceiling   ft. Ceiling   38-1/4" to 50-1/4" For   9ft. to 10 ft. Ceiling   Using Optional Accessory   ZX10SY Duct Cover   17-5/16"   C L • Drill 1/8" Pilot Holes.   • Drill 1/8" Pilot Holes.   Align edge 25-1/2" above Cooking Surface.   For ZXR758 –   26-1/4" to 38-1/2" for 8 ft. to 9 ft. ceilings.   For ZXR7510 –   38-1/4" to 50-1/4" for 9 ft. to 10 ft. ceilings.   • Use a level to draw a line straight up, from the   centerline on the template to the ceiling.   House Wiring Locations   • The junction box is located on the top of the   hood, at the front right side.   • Route house wiring as close to the installation   location as possible; through the ceiling, soffit or   back wall. Wiring should enter at least 4" above   the bracket on the right side.   6 Download from Www.Somanuals.com. All Manuals Search And Download.   Installation Instructions   3 INSTALL THE HOOD   Place the hood on the brackets and slide left to right   to align with rectangular slots at the top.   Screws “B”   To Secure Hood   To Wall   Lower   Mounting Screws   • Align the hood lower mounting holes with pilot   holes in the wall.   • Using two large flat washers (supplied), install wood   screws or wall fastener screws, loosely, into lower   mounting holes. Do not tighten.   • Level the hood by tightening or loosening the   screws “A” located on the bottom mounting   brackets.   Level and   Height   Adjustment   Screws “A”   • Tighten lower mounting screws.   • Tighten screws “B” located at the top of the   mounting bracket against the hood to clamp   the position. Do not overtighten screws.   • Adjust the installation height by tightening or   loosening the screws “A” at the bottom of the   brackets.   5 INSTALL AIR DEFLECTOR   ASSEMBLY   • Place the assembly over the hood outlet.   • Hold the assembly against the ceiling. The penciled   centerline should show through the slot on the   deflector. Mark the two screw holes on the back of   the assembly.   • Remove the   assembly and   drill 1/8" pilot   holes into   4 SIZE DUCT PIECE   • Hold upper air deflector with duct connector   against the ceiling.   • Measure from the   bottom of the support   to top of the hood   as shown. Reduce   this dimension   by 1" to facilitate   installation. The   duct will cover/   overlap the deflector   Duct   Length   Measure   Length   the wall studs.   • Enlarge holes   and the hood outlets.   that did not enter   studs to 3/8" and   tap plastic or metal   anchors into the   holes, flush with   the wall.   • Mount the assembly   onto the hood outlet,   push up against the ceiling   and install the screws provided.   • Use duct tape to seal the connection.   • Cut duct piece to   size and slip onto the   bottom of the duct   connector.   • Use duct tape to   secure duct piece   to connector.   CAUTION:   Do not use sheet metal screws   on the bottom duct flange.   7 Download from Www.Somanuals.com. All Manuals Search And Download.   Installation Instructions   6 CONNECT ELECTRICAL   7 INSTALL DUCT COVERS AND   UTILITY BARS   • Verify that power is turned off at the source.   • Separate the duct covers supplied with the hood.   • Discard the upper (inner) section.   WARNING:   If house wiring is not 2-wire   • Insert the ZXR758 or ZXR7510 duct cover (with   vent holes) into the original lower section. Be sure   that the new duct section is inside the shorter   original section.   with a ground wire, a ground must be provided by   the installer. When house wiring is aluminum, be   sure to use U.L. approved anti-oxidant compound   and aluminum-to-copper connectors.   Mounting Screw Holes   • Insert house wiring through strain relief and   tighten.   • Connect white leads to branch circuit white lead.   • Connect black leads to branch circuit black lead.   • Connect green/yellow leads to branch circuit green   lead or bare ground lead.   • Secure all connections with wire nuts on each   electrical connector.   • Push wires into junction box and replace cover.   Be sure wires are not pinched.   • Place the decorative duct covers on top of the hood.   • Insert the lower portion of the duct cover into the   impressions on the top of the hood.   • Extend the inner duct upwards to meet the ceiling   and support frame.   • Secure the duct cover to the frame with the 2 small   Phillips screws provided.   • Install the side utility bars as shown with screws   provided.   8 Download from Www.Somanuals.com. All Manuals Search And Download.   Installation Instructions   8 INSTALL FILTERS   9 FINALIZE INSTALLATION   • Remove the protective film covering the control   panel on the front face of the hood, and any other   packaging materials.   Upper Charcoal   Filter Slots   • Refer to the Owner’s Manual for operating   instructions.   Lower Grease   Filter Slots   • There are two slots inside the back and front of the   hood. These slots will hold the charcoal filters and   stainless steel grease filters in place.   Install Charcoal Filters   Upper Charcoal   Filter Slots   Grasp Tab,   Lift and Pull Forward   • Remove protective film on charcoal filters.   • Tip charcoal filters into the upper (top) slots at the   rear of the opening. Grasp the filter tab, lift and   pull forward until it rests in the front slots.   • Install all 3 charcoal filters.   Install Grease Filters   Lower   Filter Slots   • Remove protective film from grease filters.   • Tip the grease filter into the lower slots at the rear   of the opening. Lift the filter and pull the knob   forward until the filter rests on the slots.   • Install all 3 grease filters.   • To remove the filters, grasp the knob, push the   filter toward the rear and tilt downward. Grasp tabs   on charcoal filters, push toward the rear and tilt   downward.   9 Download from Www.Somanuals.com. All Manuals Search And Download.   10   Download from Www.Somanuals.com. All Manuals Search And Download.   11   Download from Www.Somanuals.com. All Manuals Search And Download.   Note: While performing installations described in this book,   safety glasses or goggles should be worn.   TM   For Monogram local service in your area, call   1.800.444.1845.   Note: Product improvement is a continuing endeavor at   General Electric. Therefore, materials, appearance and   specifications are subject to change without notice.   Pub. No. 49-80046-1   04/07 JR   GE Consumer & Industrial   GE Appliances   General Electric Company   Louisville, KY 40225   Printed in Italy   monogram.com   ©2007 GE Company   Download from Www.Somanuals.com. All Manuals Search And Download.   |