| ® CONTINUOUS FLOW ICEMAKER   WCC1401-A/WCF1411-A Series   Service Manual   Release Date: October 26, 2006   Publication Number: 630460324SER   Revision Date: N/A   Revision: A   Download from Www.Somanuals.com. All Manuals Search And Download.   TABLE OF CONTENTS   Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   Read and Follow all Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   Recognize Safety Alerts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   Different Types of Alerts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   Safety Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   Qualified Service Personnel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   Shipping And Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2   Specification Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2   Electrical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4   Refrigeration Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5   Cleaning and Sanitizing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6   Icemaker Cleaning and Sanitizing Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6   Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6   Monthly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6   Quarterly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6   Semi-Annually . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7   Refrigeration System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8   Refrigeration System Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8   Pumpdown Cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8   Expansion Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8   Water Level Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9   How Water Level Control Works . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9   Purpose of Water Level Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9   To Replace Water Level Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9   To Replace Water Level Safety Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9   Bin Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10   Gearmotor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10   Motor Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12   Start Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12   To Replace Gearmotor Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12   Auger and Extruding Head Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13   Installation and Shaft Seal Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13   Upper Nut and Bearing Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13   To Replace Bearing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13   Electrical Checkout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14   Overload Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14   Compressor Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14   Capacitor Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14   Safety Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14   Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16   Download from Www.Somanuals.com. All Manuals Search And Download.   Download from Www.Somanuals.com. All Manuals Search And Download.   Continuous Flow Icemaker Service Manual   SAFETY   SAFETY INSTRUCTIONS   Read and Follow all Safety Instructions   Read and follow all safety instructions in this manual and on the machine (decals, labels, and laminated   cards).   Read and understand all applicable OSHA (Occupation Safety and Health Administration) safety regula-   tions before operating the machine.   Recognize Safety Alerts   This is the safety alert symbol. When you see it in this manual or on the machine be   alert to the potential of personal injury or damage to the machine.   Different Types of Alerts   There are 3 types of safety alerts:   DANGER — Indicates an immediate hazardous situation which if not avoided WILL result in seri-   ous injury, death, or equipment damage.   WARNING — Indicates a potentially hazardous situation which, if not avoided, COULD result in   serious injury, death, or equipment damage.   CAUTION — Indicates a potentially hazardous situation which, if not avoided, MAY result in   minor or moderate injury or equipment damage.   SAFETY TIPS   • Carefully read all safety messages in this manual and safety signs on the machine.   • Keep safety signs in good condition and replace missing or damaged safety signs.   • Learn how to operate the machine and how to use the controls properly.   • Do not let anyone operate the machine without proper training. This appliance is not intended for use   by very young children or infirm persons without supervision. Young children should be supervised to   ensure that they do not play with the appliance.   • Keep your machine in proper working condition and do not allow unauthorized modifications to the   machine.   QUALIFIED SERVICE PERSONNEL   CAUTION — Only trained and certified electrical, plumbing and refrigeration technicians should   service this unit. ALL WIRING AND PLUMBING MUST CONFORM TO NATIONAL AND LOCAL   CODES.   SHIPPING AND STORAGE   CAUTION — Before shipping, storing, or relocating the Unit, syrup systems must be sanitized   and all sanitizing solution must be purged from the syrup systems. All liquids, after sanitizing, must   be purged from the unit. A freezing ambient environment will cause residual sanitizing solution or   water remaining inside the Unit to freeze resulting in damage to the internal components.   © 2006, IMI Cornelius Inc.   - 1 -   Publication Number: 630460324SER   Download from Www.Somanuals.com. All Manuals Search And Download.   Continuous Flow Icemaker Service Manual   GENERAL DESCRIPTION   This section gives the Unit description, theory of operation, and design data for continuous flow icemaker   series WCC1401-A.   SPECIFICATION CHART   Refrigerant   Comp.   RLA   Fan   Amps   GRMTR   Amps   Circuit   Fuse   Models   Description   VAC   HZ PH Wire   60   Oz.   Type   WCC1401-A   Ice Maker   208/230   1 2 12.2   1.2 (2) 2.0 (2)   35   404A   20   FIGURE 1   Publication Number: 630460324SER   - 2 -   © 2006, IMI Cornelius Inc.   Download from Www.Somanuals.com. All Manuals Search And Download.   Continuous Flow Icemaker Service Manual   FIGURE 2. Series WCC1401-A/WCF1411-A Dimension Drawing   © 2006, IMI Cornelius Inc.   - 3 -   Publication Number: 630460324SER   Download from Www.Somanuals.com. All Manuals Search And Download.   Continuous Flow Icemaker Service Manual   ELECTRICAL   FIGURE 3. Schematic WCC1401-A/WCF1411-A   Publication Number: 630460324SER   - 4 -   © 2006, IMI Cornelius Inc.   Download from Www.Somanuals.com. All Manuals Search And Download.   Continuous Flow Icemaker Service Manual   REFRIGERATION SCHEMATIC   Condenser   Evaporator   TXV   Dryer   Compressor   FIGURE 4. WCC1401-A   © 2006, IMI Cornelius Inc.   - 5 -   Publication Number: 630460324SER   Download from Www.Somanuals.com. All Manuals Search And Download.   Continuous Flow Icemaker Service Manual   CLEANING AND SANITIZING   ICEMAKER CLEANING AND SANITIZING PROCEDURES   Do not use any of the ice made during cleaning operations.   Clean and sanitize ice storage area when cleaning icemaker.   1.   2.   3.   4.   Turn off machine.   Shut off water supply   Remove ice from storage bin.   Mix approved cleaner (4 gallons as directed). Recommended cleaner: Calgon Nickel-Safe, ice   machine cleaner. Mixture: 3 ounces per gallon of water.   5.   Clean auger/diverter assembly and ice transition/drop tube in a sink using cleaner mixture and   reinstall in icemaker. Using cleaner, wipe down dispense tray.   6.   7.   8.   9.   Turn machine on and add cleaner solution to water level control, 2 gallons to each control.   Turn on water supply and run machine for 15 minutes.   Turn off machine and remove all ice. Turn off water and drain water.   Sanitize using household liquid bleach (299 ppm chlorine). Mixture: ½ fluid ounce per gallon room   temperature water. 2 minute exposure time.   10. Sanitize auger/diverter assembly and ice transition/drop tube in a sink using sanitizing solution and   reinstall in icemaker. Using sanitizer, wipe down dispense tray.   11. Fill icemaker with sanitizer by slowly pouring solution into water feed reservoir until full. Solution will   drain through overflow tube. Turn on water. Run the icemaker for 15 minutes. Turn off ice machine   and remove all ice.   12. If icemaker is used in conjunction with ice dispenser or storage bin, follow manufacturer’s   recommended cleaning instructions at this time.   MAINTENANCE   Preventive maintenance can increase the trouble free life of your icemaker. Many authorized service   agencies offer service contracts for your icemaker. Contact your local distributor for further information.   Monthly   1.   Clean the condenser. Use a brush, vacuum cleaner or blower from inside with air or CO2 gas.   2.   Inspect water feed reservoir at least once a month until a definite pattern for cleaning and sanitizing   has bee established.   Quarterly   This is the maximum period of time between cleaning and sanitizing the icemaker. In addition to rec-   ommended monthly procedure, and if a more frequent cleaning and sanitizing pattern has not been   established, unit must be cleaned and sanitized.   Publication Number: 630460324SER   - 6 -   © 2006, IMI Cornelius Inc.   Download from Www.Somanuals.com. All Manuals Search And Download.   Continuous Flow Icemaker Service Manual   Semi-Annually   Semi-Annually in addition to all previously established service procedures perform the following:   1.   2.   3.   4.   5.   6.   7.   Check for water leaks in tube connections, water fittings and lower icemaker water seal.   Check drain tubes for clogs and aged tubes. Replace if tubes are stained or brittle.   Check for signs of condensation. Clean where necessary and replace insulation properly.   Check safety circuits for proper operation.   Check refrigeration system.   Check unit for abnormal noise. Tighten machine and cabinet screws if necessary.   Check white upper bearing on auger assembly. If bearings are less than 1/16” thick, replace.   REPLACE   OK   1/16   1/16   OK   REPLACE   FIGURE 5. UPPER NUT AND BEARING ASSEMBLY   © 2006, IMI Cornelius Inc.   - 7 -   Publication Number: 630460324SER   Download from Www.Somanuals.com. All Manuals Search And Download.   Continuous Flow Icemaker Service Manual   REFRIGERATION SYSTEM   Suction Pressure +- 2 lb.   Water Temperature   Discharge Pressure +- 10 lbs.   Water Temperature   50°   18   20   20   21   23   27   70°   18   20   20   21   23   27   90°   18   20   20   21   23   27   50°   213   220   225   230   251   302   70°   213   220   225   230   251   302   90°   213   220   226   231   252   303   50°   60°   70°   80°   90°   105°   50°   60°   70°   80°   90°   105°   REFRIGERATION SYSTEM ADJUSTMENTS   A complete understanding of the icemaker and hermetic refrigeration system is necessary before any   adjustments are made. The refrigeration technician must use high and low side pressure readings, water   and air temperatures, plus general conditions of cleanliness to assess the refrigeration system status   when making any adjustments.   All icemaker products are tested and adjusted at the factory prior to shipment where the ambient   temperature ranges from 650F to 900F, depending on the season of the year.   Whenever a new icemaker is initially installed and started-up, it is imperative that the start-up operator   make the following checks and readjustments for local conditions.   PUMPDOWN CYCLE   The Series1400 unit is a split system. The icemaker consists of two gearmotor/evaporator assemblies   and a liquid line solenoid. The condensing unit consists of a compressor, condenser, fan motor and   receiver. The icemaker is designed for indoor use only. The condensing unit is designed for outdoor use.   The two units are connected with a precharged line kit.   The system operates on a pump down cycle. When the bin thermostat senses ice it opens the circuit to   the liquid line solenoid. The liquid line solenoid closes and stops the flow of refrigerant to the evaporators.   This causes the suction pressure to drop. The condensing unit is shut off when the suction pressure   drops below 5 psig. The low-pressure control should be adjusted to open between 0-5 psig and close   between 15-20 psig. Note: there is no electrical connection between the two units.   EXPANSION VALVE   You will find a thermal expansion valve on icemakers, which is used to control the amount of refrigerant   flowing through the evaporator. Improperly installed or defective expansion valves may cause low   production, soft ice, squeaking from evaporator and excessive load inside evaporator.   By using general refrigeration trouble shooting along with the pressure charts, you can easily determine   whether or not the expansion valve is working properly.   NOTE: Units with thermostatic expansion valve, the valve is located on bottom refrigerant line.   Sensing bulb is located on top refrigerant line.   Very high discharge pressure is present in system. Quick disconnects on your gages will minimize   Danger and loss of refrigerant. Comply with federal regulations for reclaiming refrigerant.   Publication Number: 630460324SER   - 8 -   © 2006, IMI Cornelius Inc.   Download from Www.Somanuals.com. All Manuals Search And Download.   Continuous Flow Icemaker Service Manual   WATER LEVEL CONTROL   HOW WATER LEVEL CONTROL WORKS   When water is introduced through the inlet fitting the float rises, the float pushes against a lever that in   turn, forces the poppet assembly against the inlet fitting valve seat that seals the water off. See Figure 1   (page 7). Before the water inlet is sealed, the safety switch is operated. In the event of a water failure the   float would drop down and operate the safety switch to shut off the machine.   If water level control will not shut off and seal at level as indicated, be sure inlet pressure does not exceed   recommended factory operating range.   Under ordinary circumstances adjustment should not be necessary providing it was properly adjusted   when unit was installed or relocated. If however, the control becomes inoperative, repair or replace. See   Start-up Adjustment in the installation manual.   PURPOSE OF WATER LEVEL CONTROL   1.   To automatically maintain proper water level in the evaporator when the unit is running and making   ice.   2.   A safety switch is operated in the event of an interruption in water supply. The switch shuts off the   electrical power to the icemaker and its refrigeration system. Switch will reset as soon as cause of   water failure has been corrected and proper water level in icemaker has again been reached.   3.   The transparent bowl not only provides a visible check of water level, but also is a good guide to the   internal conditions which exist within the icemaker assembly itself. (See cleaning procedure.)   TO REPLACE WATER LEVEL CONTROL   1.   Shut off the water supply. Shut off the main power switch or unplug the ice dispenser from electrical   outlet.   2.   Remove the flexible tubing from bottom of water level control and drain water from water level   control and evaporator.   3.   4.   5.   Remove flexible tubing at bottom of water level bowl connected to the overflow.   Hold water inlet fitting with proper tool to prevent it from rotating when disconnecting the water inlet.   Remove wing nut holding water control to its mounting bracket. Control can be removed by lifting   straight up.   TO REPLACE WATER LEVEL SAFETY SWITCH   1.   2.   3.   Shut off main power switch or unplug the ice dispenser from electrical outlet.   Unplug Molex connector connecting switch to electrical box.   Remove the 2 screws anchoring the water level safety switch to the bottom of the water level control   mounting bracket.   © 2006, IMI Cornelius Inc.   - 9 -   Publication Number: 630460324SER   Download from Www.Somanuals.com. All Manuals Search And Download.   Continuous Flow Icemaker Service Manual   BIN CONTROL   The type of bin control used on all WCC and WCF Models is an electronic control. The control is supplied   with power to terminals X1 and X2. Terminals X3 and X4 are a normally closed switch which open when   the thermostat sensor bulb senses ice. The WCC1401-A/WCF1401-A uses 2 controls, terminals X1 and   X2 are connected in parallel and terminals X3 and X4 are connected in series.   The sensing bulbs are located in a 5/16” stainless steel tube which hangs from the dispense tray covers   down through the center of the drop tube.   To test the switch, start the icemaker and block the outlet tube, about ½ full the icemaker should shut off.   When the tube is cleared the icemaker should restart within 5 min.   The Bin controls are in electrical series with the coil on the antifreeze relay along with the low water   safety.   The controls are held in place inside the electrical box by 4 screws. The control bulbs are in the drop   tubes. They can be removed by pulling the cable located on the top of the dispense tray cover. When   replacing the sensor make sure the bulb is inserted to the bottom of the thermostat well.   GEARMOTOR   The gearmotors are equipped with a start relay and a manual reset overload.   When current is applied, the relay energizes and completes the circuit to the start winding. The motor   reaches a predetermined speed and the relay drops out, disconnecting the start winding. The run   winding remains in the circuit as long as current is applied.   The purpose of the overload is to automatically shut off the motor in the event of a mechanical bind of the   transmission, an overload condition within the evaporator or an electrical malfunction. It does this by   sensing amperage draw. If the motor stalls the start relay would energize and stay energized. The   amperage would surge 5 to 6 times greater than normal draw. In this event the overload would shut off   the transmission in 4 to 8 seconds.   If the motor is subjected to abnormal load, but does not reach stall condition, the overload will react, but   over a greater period of time. The reaction time depends upon the amperage to which it is subjected.   The overloads to each motor are connected in series; if either overload trips both gearmotors and the   liquid line solenoid are shut off.   Publication Number: 630460324SER   - 10 -   © 2006, IMI Cornelius Inc.   Download from Www.Somanuals.com. All Manuals Search And Download.   Continuous Flow Icemaker Service Manual   GEARMOTOR   OVERLOAD TRIPPED   Check water level control   and evaporator water tube   for line build-up restrictions.   NO   YES   CAUTION   evaporator and   auger before   resetting overload.   Clear ice from   CLEAN   See Instructions.   Reset overload.   IMPORTANT   Icemaker   runs.   Will not   Reset.   Resets but   motor does   not run.   Icemaker runs when   reset but problem has   not been found.   Continue checking for   overload as follows to   guard against future   problems.   Short run. Trips   again in 2   minutes. Check   gearmotor circuits.   Overload   hot try   again.   Resets but   motor does   not run.   Will not   reset.   Replace   overload.   Check   gearmotor   circuits.   OVERLOAD GUIDE   ELECTRICAL:   High or low voltage. Weak power lines can cause overloads on icemakers restarts.   High running current (2.4amps or above). Check motor circuits and start relay.   Auger delay failed.   ICEMAKER   Mechanical parts worn. Scored evaporator or auger. Worn thrust bearing.   Icemaker not turning off. Failed ice level control.   Over compression. Low water inlet temperature. Restrictions in water line from reservoir.   REFRIGERANT   Contaminated charge or bad compressor.   Low charge or gas leak.   Low suction pressure. Improper expansion valve. Sensing bulb location or insulation   and/or defective expansion valve.   © 2006, IMI Cornelius Inc.   - 11 -   Download from Www.Somanuals.com. All Manuals Search And Download.   Publication Number: 630460324SER   Continuous Flow Icemaker Service Manual   MOTOR CHECK   The resistance readings on the winding will be between 5 to 25 ohms. A meter capable of these low   readings must be used. The start relay cover must be removed.   If no continuity on start or run winding test, replace gearmotor. If continuity on grounded motor test,   replace gearmotor.   START RELAY   1.   Check between “2” and “4” on relay (with relay unplugged). If there is continuity replace the relay, as   the relay contacts should be open.   2.   Check between “3” and “4” on relay, if no continuity replace the relay.   FIGURE 6. GEARMOTOR ASSEMBLY   TO REPLACE GEARMOTOR ASSEMBLY   1.   2.   3.   4.   Disconnect the icemaker from the electrical power source.   Disconnect the transmission cable from the electrical box.   Remove the 4 hex head bolts securing the evaporator to the top of the transmission.   Remove the 4 bolt’s holding the transmission and bracket to frame base, while supporting the   weight of the evaporator. Remove the transmission from the unit.   5.   When replacing the transmission, it may be necessary to rotate the auger back and forth to align   the motor shaft and auger.   AUGER NUT   AUGER   BEARING NYLON   BEARING DELRIN   “D” DRIVE   GROOVE   EXTRUDING   HEAD   ANTI–ROTATION   RIB – 3 PLACES   FIGURE 7. AUGER AND EXTRUDING HEAD REMOVAL   Publication Number: 630460324SER   - 12 -   © 2006, IMI Cornelius Inc.   Download from Www.Somanuals.com. All Manuals Search And Download.   Continuous Flow Icemaker Service Manual   AUGER AND EXTRUDING HEAD REMOVAL   1.   2.   3.   4.   Disconnect unit from power supply.   Remove storage container cover and put aside.   Turn off water supply to icemaker.   After ice has melted from head take hold of the auger nut and lift straight up to disengage from   icemaker.   5.   When replacing the auger assembly, make certain that both the auger engages the output shaft   drive and the extruding head ribs engage the evaporator tube.   INSTALLATION AND SHAFT SEAL REPLACEMENT   1.   Place shaft seal locator seat and shaft   seal mount over gearmotor output shaft   and push down until shaft seal seat and   shaft seal mount rest flush on top of   gearmotor.   2.   Place rubber coated ceramic seal   (important: ceramic face up) over output   shaft and push down until seal nest in   recess of shaft seal mount. (lubricate   rubber on ceramic seal with rubber   lubricant).   E–RING   WASHER, PLAIN FLAT   SHAFT SEAL   MOUNT, SHAFT   SEAL   3.   4.   Place shaft seal with carbon face down   (spring up) over output shaft and push   (gently) downward until seal rests on   carbon face of the output shaft seal.   SEAT, SHAFT SEAL   Place flat washer over output shaft and let   rest on the output shaft seal. Push down   on the washer compressing the spring on   the output shaft seal. While holding the   seals (down) in place slide the E–ring into   the groove on the output shaft   GEARMOTOR   FIGURE 8. SHAFT SEAL 700 AND 1000   UPPER NUT AND BEARING ASSEMBLY   The upper white bearing located on top of the auger is used to absorb the force between the auger and   extruding head.   NOTE: The bearings are 3/32 thick. When they wear below 1/16 they should be replaced. Bearings   to be inspected for wear during quarterly maintenance.   To Replace Bearing   1.   Disconnect unit from electric power.   2.   3.   4.   Remove top panels.   Remove Dispense Tray Cover.   Use an open end wrench on auger nut connected to bearing and turn counterclockwise to remove   assembly.   5.   Remove worn bearings. Replace with new bearings and then reinstall assembly.   NOTE: If auger turns with nut, remove cover on top of gearmotor stator and hold motor while   loosening nut.   © 2006, IMI Cornelius Inc.   - 13 -   Publication Number: 630460324SER   Download from Www.Somanuals.com. All Manuals Search And Download.   Continuous Flow Icemaker Service Manual   ELECTRICAL CHECKOUT   1.   2.   3.   Be sure the unit is disconnected from the power source. Remove the compressor electrical box   cover. Check for obvious damage and loose wires.   Disconnect the fan motor leads. Since capacitors store energy, short the capacitor with a   screwdriver. This will prevent shocks.   Disconnect the compressor terminal wires.   OVERLOAD CHECK   Using a volt–ohmmeter check the continuity   across the overload, contact #1 and #3. If none,   wait for unit to cool down and try again. If still no   continuity, the overload protector is defective   and should be replaced.   FIGURE 9. OVERLOAD CHECK   COMPRESSOR CHECK   The resistance readings on the windings will be   between 0.25 to 10.00 ohms, a meter capable of   these low readings must be used.   1.   Check between “C” and “R.” Replace the   compressor if there is no continuity as the   run windings are open.   2.   Check between “C” and “S.” Replace the   compressor if there is no continuity as the   start windings are open.   FIGURE 10. COMPRESSOR CHECK   3.   4.   Check between “C” and “R” or “S” and the shell of the compressor. If there is continuity, replace the   compressor as the motor is grounded.   Check between screw terminal on the overload and “C” on the compressor. Check and repair the   lead or connections if there is no continuity.   CAPACITOR CHECK   1.   2.   Check or replace start capacitor, disconnect bleed resistor before checking for shorted capacitor.   Check or replace run capacitor (if supplied) check for shorted capacitor or either terminal grounded   to case.   SAFETY CONTROLS   Your icemaker unit has several safety and control devices incorporated into its design.   WARNING: None of the below described devices should ever be “bypassed” to allow the unit to   function.   The safety and control system shut–off devices are:   1.   2.   3.   4.   5.   6.   7.   Low water shut off reed switch located in icemaker float assembly. (Automatic reset type.)   Gearmotor thermal overload, manual reset type (red button on motor).   Compressor thermal overload, automatic reset type.   Anti–freeze relay and associated circuit. See wiring diagrams.   Main service switch located on top of the control box.   Bin Control.   High pressure cut out (water cooled only).   Publication Number: 630460324SER   - 14 -   © 2006, IMI Cornelius Inc.   Download from Www.Somanuals.com. All Manuals Search And Download.   Continuous Flow Icemaker Service Manual   GUIDE TO GOOD ICE   CHECK ICEMAKER   LOCATION CONDITIONS   FIRST   CUSTOMER   COMMENTS   CHECK ICE MAKER   “It runs but the ice is   too soft.”   Proper air flow for condens-   ing system.   Use gauges for checking   suction and head   pressures. See manual   for correct reading and   conditions. Check frost   line and sight glass.   “The icemaker is not   Location too close to high   units such as coffee urns,   deep fryers, grills, etc.   producing enough ice.”   “The ice is too wet.”   Supply water conditions   Check water level for   proper adjustment and   restrictions. See   Manual.   Water too warm   (above 90oF).   Water artificially softened   above 262 ppm sodium chlo-   ride.   Check evaporator   assembly for worn   parts, bearings, scored   evaporator and auger,   bad expansion valve.   etc.   Normal water supply too high   in total dissolved solids   (above 500 PPM).   “It makes too much   noise.”   (With this comment   the ice is usually   extremely hard and   larger than normal.)   Check to see if noise   objection is normal fan and   air flow noise.   Check for loose parts   and screws rattling.   Check evaporator   assembly for worn   parts, bearings, scored   evaporator and auger,   bad expansion valve,   etc.   Over   Compression   Supply water conditions.   Water too cold (below   50oF). (Possibly running   from pre-cooler.)   Obstructions partially   blocking ice exit from top of   evaporator.   Check fan and fan shroud.   © 2006, IMI Cornelius Inc.   - 15 -   Publication Number: 630460324SER   Download from Www.Somanuals.com. All Manuals Search And Download.   Continuous Flow Icemaker Service Manual   TROUBLESHOOTING   Publication Number: 630460324SER   - 16 -   © 2006, IMI Cornelius Inc.   Download from Www.Somanuals.com. All Manuals Search And Download.   Continuous Flow Icemaker Service Manual   © 2006, IMI Cornelius Inc.   - 17 -   Download from Www.Somanuals.com. All Manuals Search And Download.   Publication Number: 630460324SER   IMI Cornelius Inc.   Download from Www.Somanuals.com. All Manuals Search And Download.   |