OWNER'S MANUAL
MODEL SL920
COMMERCIAL SLIDE GATE OPERATOR
SL920 GATE OPERATORS ARE FOR USE ON VEHICULAR PASSAGES
ONLY AND NOT INTENDED FOR USE ON PEDESTRIAN PASSAGE GATES.
2 YEAR WARRANTY
Serial#_____________________
(located on electrical box cover)
InstallationDate:_______________
Download from Www.Somanuals.com. All Manuals Search And Download.
General Information
OVERALL DIMENSIONS: Height: 21" Length: 12" Width: 17"
SHIPPING WEIGHT: 125 lbs.
z Options: Steel Mounting Stand: 23 lbs.
POWER REQUIREMENT: Dedicated 115 Volt AC (+/- 10V), 5 AMP Power Circuit
APPLICATIONS:
z Maximum Gate Weight: 500 lbs.
z Maximum Gate Length: 25 ft.
z Maximum Track Grade: 5 % (1 ft. rise over 20 ft. run)
z Maximum Gate Speed: 10"/sec.
INCLUDED WITH OPERATOR:
BASE PLATE HOLE PATTERN
z 30-Feet of # 40 Roller Chain
z 2-Master Links # 40
z 2-Zinc Plated Chain Bolts
z 2-Chain Brackets, Right and Left
z 2-U-Bolts, Round (for chain brackets)
z 2-U-Bolts, Square (for chain brackets)
z 2-Safety Warning Placards
z 1-Hex Wrench 5/16"
z1-InstructionManual
z 1-Flexible Conduit End Fitting 1/2"
z 4-Sleeve Anchor Bolts (red heads) 3/8" X 3"
3
Download from Www.Somanuals.com. All Manuals Search And Download.
General Information continued...
CIRCUIT BOARD: The SL920 uses the Full Systems Capability circuit board, a powerful control
system. This circuit board operates on 12 ~ 18 Volts and can deliver power to the motor through high
power switching. The limit switch input terminals require the use of normally open type limit switches.
These switches are used to accurately stop the gate operator in the open and closed positions. To
safeguard the operator from damage that could result from limit switch or system protection failure, the
Full Systems Capability circuit board has a built-in maximum run timer which will allow the operator to run
for approximately 300 seconds and then shut off automatically. The Full Systems Capability circuit board
has an adjustable gate sensitivity feature which will stop or reverse the gate if the gate is pushing harder
thannormalbecauseofanobstruction.
GATE SENSITIVITY: The SL920 Full Systems Capability circuit board has a built-in system
protectionfeaturewhichwhenadjustedproperlywilldeliveronlyenoughpowertothemotortoovercome
the resistance of the gate. The amount of power that the circuit board will deliver can be adjusted for both
directions of travel to accommodate the various gate weights that the SL920 operator is recommended
for. (See Applications Pg. 3)
Vehicular Gate Operator Classes:
Class I - Residential Vehicular Gate Operator: A vehicular gate operator (or system) intended for use in a home of
one-to four single family dwellings, or a garage or parking area associated therewith.
Class II - Commercial/General Access Vehicular Gate Operator: A vehicular gate operator (or system) intended for
use in a commercial location or building such as a multifamily housing unit (five or more single family
units), hotel, garage, retail store, or other building servicing the general public.
Class III - Industrial/Limited Access Vehicular Gate Operator: A vehicular gate operator (or system) intended for use
in an industrial location or building such as a factory or loading dock area or other locations not intended
to service the general public.
Class IV - Restricted Access Vehicular Gate Operator: A vehicular gate operator (or system) intended for use in a
guarded industrial location or building such as an airport security area or other restricted access location
not servicing the general public, in which unauthorized access is prevented via supervision by security
personnel.
Gate Operator model SL920 is intended for Vehicular Gate Operator Classes I, II, III, and IV.
Gate Inspection:
a) Install the gate operator only when:
1) The operator is appropriate for the construction of the gate and the usage Class of the gate,
2) All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum
of 4 ft. above the ground to prevent a 2-1/4 " diameter sphere from passing through the openings
anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position.
3) All exposed pinch points are eliminated or guarded, and
4) Guarding is supplied for exposed rollers.
b) The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a
separate access opening.
c) The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent
structures then opening and closing to reduce the risk of entrapment.
d) The gate must be properly installed and work freely in both directions prior to the installation of the gate operator.
Do not over-adjust the gate sensitivity to compensate for a damaged gate.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Features
OPERATION
The SL920 Full Systems Capability can operate in a AUTO CLOSE TIMER (TIMER ON) or a
PUSH-TO-OPEN/PUSH-TO-CLOSE(TIMEROFF)modeofoperation.IntheAUTOCLOSETIMER
mode of operation the operator is given a command to open the gate and hold it open until the input is
released and until the auto close timer has elapsed at which point the operator will close the gate
automatically. In the PUSH-TO-OPEN/PUSH-TO-CLOSE mode of operation each time a signal is sent to
the operator, it will cause it to do the opposite of what it did before. (i.e., If the gate is closed, it will start
opening, if it is open, it will start closing: If it is closing, it will REVERSE TO OPEN, if it is opening, it will
REVERSE TO CLOSE.)
CONTROLS
The SL920 Full Systems Capability works with the following control devices: Key switches, Push
buttons (separate or intercom), numerical key pads and any peripheral equipment which can supply
normally open or normally closed contacts as well as optional radio transmitters and receiver (specified
byandavailablefromthemanufacturer). Thesecontactscanbeconnectedtotheoperatorinputterminals
to perform the opening, close, safety, or the stop functions.
AUTO CLOSE TIMER
The operator comes factory preset with the auto close timer turned OFF. The auto close timer will
close the gate automatically after a specific amount of time has elapsed. The amount of time can be
easily adjusted between 0 and 45 seconds by turning a small "pot" located on the right edge of the circuit
board (See page 17). The timer can be disabled or activated by flipping a single switch located on the
top right edge of the circuit board. If the timer will be used it is recommended that some type of
supplementary safety device be installed. If more time is required, there is an extended timer available
from the manufacturer allowing up to 100 additional seconds (See Options).
MANUAL RELEASE SWITCH
This simple on-off switch is built into the operator. In an emergency, EVEN WITH THE POWER
OFF, the gate can be pushed open manually after flipping the switch from Operate to Release. This
switch may also be removed and placed externally from the machine.
GATE SENSITIVITY ADJUSTMENT FOR SYSTEM PROTECTION
The amount of force necessary to stop the gate can be adjusted to conform to the various sizes
and weights of any particular gate. When adjusting the sensitivity, the operator can be given only as much
energy as is necessary to overcome the resistance of the gate. If the gate should strike an obstruction in
either direction, the gate will reverse. If the gate should again strike an obstruction before reaching a limit,
the gate will stop, remain stopped, and will sound an alarm. (See page 17)
MASTER AND SECOND
Some very large entrances may require the use of two gates. If this is the case, the two gates can
be easily automated using the "master and second" configuration. This configuration uses two gates and
two operators in ONE driveway. The operators used are two regular SL920 Full Systems Capability
operators one of which is of standard "right hand operation" and the other which is easily converted to
"left hand operation" by flipping a single switch located at the top of the circuit board (See page 17).
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts Identification
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts Identification continued...
K74-40065 SERVICE KIT
EXTERNAL RESISTOR
DESCRIPTION
K72-30359 SERVICE KIT
LIMIT/DRIVE SHAFT ASSEMBLY
DESCRIPTION
F
A
QTY
QTY
1
EXTERNAL CURRENT RESISTOR
LIMIT/DRIVE SHAFT
BEARING
SHRINK WRAP, 1"
2
2
2
1
1
2
SCREW, PH PHILLIPS, #2-56 X 1/2"
LOCKNUT, #2-56
LIMIT NUT
2
SPROCKET, 41B20, 1/4" KW, (2) 1/4" SS
KEY, WOODRUFF, 1/4" X 7/8"
Steel shim washer, 1" x 1.5" x 0.010"
Steel shim washer, 1" x 1.5" x 0.031"
HEX BOLT, 3/8-16 X 1"
FLANGE NUT, 3/8-16
1
WIRE, GREEN, 8", STIP X FORK
WIRE, YELLOW, 8", STIP X FORK
1
1
2
4
K75-40346 SERVICE KIT
4
G
IDLER SPROCKET
E-RING, 1"
1
DESCRIPTION
SPROCKET, 41B24, 3/16" KW, (2) 1/4" SS
BEARING, 1/2" ID x 3/4" OD x 1/2"
QTY
1
K74-40084 BRIDGE RECTIFIER ASSEMBLY
B
QTY
1
1
1
2
1
DESCRIPTION
CAPACITOR, RECTIFIER
BRIDGE RECTIFIER
HEX BOLT, 5/8-11 X 2-3/4", GRADE 5
HEX JAM NUT, 5/8-11
1
LOCKWASHER, 5/8
SCREW, PH PHILLIPS, #6-32 X 1"
FLANGE NUT, 6-32
1
1
K75-40402 SVC. KIT DRIVE SPROCKET
DESCRIPTION
H
QTY
1
K75-30349 SERVICE KIT
GEAR BOX, W/ SPROCKET
DESCRIPTION
C
SPROCKET, 41B18, 1/4" KW, (2) 1/4" SS
KEY, WOODRUFF, 1/4" X 7/8"
QTY
1
GEAR BOX
1
4
4
1
1
HEX BOLT, 1/4-20 X 3/4"
LOCKWASHER, 1/4"
K75-40403 SVC. KIT, REDUCTION SPROCKET
J
QTY
1
KEY, 1/8" X 1-1/8"
DESCRIPTION
SPROCKET, 35B54, 1" Bore
SPROCKET, 35B12 X 5/8" BORE
KEY, WOODRUFF, 1/4" X 7/8"
1
K74-40386 SVC. KIT, LIMIT SWITCH
D
QTY
2
DESCRIPTION
LIMIT SWITCH
K74-40378 SVC. KIT, OPERATOR COVER
DESCRIPTION
K
QTY
1
HEX STANDOFF4-40 x 1-1/2 F/F
LIMIT SWITCH ACTUATOR PLATE
LOCKNUT, #8-32
4
COVER, SL920 & 930
1
LABEL, LIFTMASTER BUBBLE
SCREW, SOCKET, 3/8-16 X 1"
WASHER, 5/16, INTERNAL GRIP, PLASTIC
1
2
4
LOCKWASHER, #4
8
4
SCREW, PH PHILLIPS, #4-40 X 5/8"
SCREW, PH PHILLIPS, #8-32 X 1"
SPRING, LIMIT PLATE
8
2
50-19914 RADIO KIT (OPTIONAL)
DESCRIPTION
2
QTY
412HM RADIO
1
1
2
2
2
2
2
2
K74-40045 SERVICE KIT
E
CABLE EXTENSION KIT
STICK-ON CABLE FASTENER
PCB GUARD AND STANDOFF
DESCRIPTION
GUARD, PCB
QTY
6-32 x
½
PAN HEAD SCREWS
1
3
4
4
4
4
6-32 x 1 HEX MALE/FEMALE STANDOFF
#6 FLAT WASHER
JUMPER, PCB
HEX STANDOFF, 6-32 x 1", M/F
HEX STANDOFF, 6-32 x 1/2", F/F
SCREW, PH PHILLIPS, #6-32 X 1/4"
SCREW, PH PHILLIPS, #6-32 X 3/8"
#6 LOCK WASHER
#6 NUT
3" STRIP OF FLEX-GROMET
1
INDIVIDAUL PARTS
DESCRIPTION
ITEM
PART #
QTY
2
13-40362
1
2
3
LIMIT NUT
20-40381 MOTOR, 24VDC, 1/5 HP
21-40074
1
XFMR, 120V, 60HV
1
5
5
23-40050 LIMIT SWITCH
2
23-40357 SWITCH SPST, TOGGLE
25-40356 CIRCUIT BREAKER, 5 AMP
29-40089 SONALERT PIEZO ALARM
29-40355 RESISTOR 10 OHM
1
6
1
7
1
8
1
9
29-NP712 BATTERY, 12V 7AH
1
K79-40056
10
PCB, COMPLETE, FULL SYSTEM
1
11 K79-40370
12 25-2015
PCB, BATTERY CHARGE
BREAKER 15AMP
1
1
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
TEST OPERATOR
Remove the gate operator from it's
package and make sure that all parts are
included.RefertoGeneralInformationand
Parts Identification. If any parts appear to be
missing, contact dealer.
1
Temporarilyplugtheoperatorinto
115 Volt outlet or extension cord.
Before beginning installation, test the
gate operator by running the operator back
and fourth 2 or 3 times. If the gate operator
appearstohaveanyshippingdamage,
contact a dealer.
2
The operator may be run back and
fourth by momentarily touching the open input
terminals together. The terminals can be
touched together with a short length of wire,
paper clip or needle nose pliers. With full
systems capability circuit board, the open
input terminals are 5 and 6.
Disconnect Power when finished!
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Installationcontinued...
GATE PREPERATION
Disconnect Power from the gate
operator!
3
The tail end of the gate should
extend approximately 24" beyond the edge of
the driveway. If this is not the case, an
extension tail will need to be added to the
gate. This will give room for the gate operator.
Make the extension tail 24" X 24" as shown.
If the gate has not yet been fabricated, add
24" to the length of the gate.
CEMENT PAD LOCATION
If no concrete surface exists to
attach the gate operator to, make a cement
pad 16" X 24" X 10". The cement pad should
be at least 6" in depth and extend below frost
line. If it is desirable to elevate the gate
operator it may protrude 4" or more above
ground as shown. Place the shortest pad
edge even with the driveway edge. Place the
longer edge of the pad 1" away from the gate.
4
OPTIONAL MOUNTING STAND
If the steel mounting stand will be
used, place the shortest edge of the stand 4"
from the driveway edge and place the longest
edge of the stand 4-1/2" away from the gate.
The top of the steel stand may sit on the
ground or the stand may be elevated to keep
the operator above snow, flooding etc. Make
a post hole and cement the stand in place,
making sure the stand is level and square to
the gate.
5
9
Download from Www.Somanuals.com. All Manuals Search And Download.
InstallationContinued...
POSITION GATE OPERATOR
If the steel mounting stand was used,
simply bolt the gate operator to the stand. If
the operator will be mounted to a concrete
surface or pad, place the shortest edge of the
operator 4" away from the edge of the
6
driveway. Place the longer edge of the gate
operator 2-1/2" away from the gate.
ANCHOR THE OPERATOR
When the gate operator is correctly
positioned on the concrete surface or pad,
mark the base hole locations onto the
cement with a felt tip marker or equivalent.
Once marked, move the operator to the side
and drill the 4 holes using a 3/8" masonry bit.
Place the operator back into position. Insert
the four sleeve anchors into the holes and
firmly tighten.
7
THREADING THE CHAIN
Now that the operator is firmly
attached, the chain may now be connected to
the gate and operator. Begin by threading the
chain through the sprockets. The sprockets
come arranged as shown so that the chain
may be threaded under the idler sprockets
and over the drive sprocket. Alternately, the
chain may be threaded over the idler sprock-
ets and under the drive sprocket by moving
the idler sprockets to the alternate positions
above. Note: the cover will need to be modi-
fiedforthealternatearrangement.
8
10
Download from Www.Somanuals.com. All Manuals Search And Download.
InstallationContinued...
ATTACH CHAIN TO GATE
9
Attach the gate bracket to the gate
as shown using the round or square u-bolts
forroundorsquaregateframesrespectively.
Attach the chain to the gate brackets using
the chain bolt and master link as shown. If
necessary, the chain may be easily short-
ened using a chain breaker. Adjust the height
of the gate brackets until the chain is level
and firmly tighten the u-bolts. For round gate
frames it may be necessary to drive the self
tapping screw through the gate bracket, and
into the gate.
ADJUST LIMITS
The limit nuts need to be adjusted to
cause the gate to stop in the desired open
and closed positions. These adjustments can
beroughlymadebeforepowerhasbeen
hooked up by flipping the manual release
switch and pushing the gate manually. Push
the gate to the open position and adjust the
limit nut to press the limit switch in. The limit
nuts can be turned after pressing down on the
guide plate. Push the gate closed and adjust
the other limit nut to press in the other limit
switch. Caution "do not allow the limit nuts to
travel past the switch as this may damage
the switches". When finished, make sure the
guide plate is properly engaged with the
grooves on the limit nuts.
10
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Alternate Installations
REAR MOUNT PLACEMENT
The rear mount installation is an
excellent way to conceal the chain or opera-
tor. The operator is placed in the extreme rear
of the gate as shown and the chain never
goes across the driveway. The chain only
goes from the gate operator to a post or wall
beside the driveway. Place shortest edge of
the operator 3" from the rear end of the gate
and place the long edge of the operator 3-1/2"
away from the gate toward the wall.
CHAIN ARRANGEMENT
The chain will form a continuous
loop, going around the drive sprocket on the
operator, and around the idler sprocket on the
post or wall. Only one gate bracket is
required on the rear edge of the gate where
both ends of the chain come together and
attach to the bracket. To prepare the SL920
for a rear mount installation, remove one or
both idler sprockets from the operator.
Neither idler sprocket will be needed on the
gate operator. For the idler sprocket, an
ES130 End Sprocket Assembly with chain
guard may be used. Alternately, an idler
sprocket that was removed from the gate
operator may be used. It is recommended
that a cover be placed over the idler sprocket
in this case for safety.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
CONDUIT ROUTING
Make sure that power is OFF
before making any electrical connections!
Be sure that all wiring is employed
as required by local codes.
1
The operator is provided with two
knockout holes on each side. Run 1/2" liquid
tight flexible conduit through one of the four
knockout holes and into the handy box where
the receptacle is located. An elbow fitting is
attached to the handy box and a straight
fitting is supplied for the other end of the
flexible conduit. Run three 12 gauge wires
through the flexible conduit and into the
handy box. There should be a black or other
colored wire for hot, a white wire for neutral,
and a green wire for earth ground.
STANDARD 115 VOLT HOOK-UP
Connect the three 12 gauge wires to
the 115 Volt receptacle.
Connect the black (hot) wire to the
brass screw.
Connect the white (neutral) wire to
the silver screw.
Connect the green (ground) wire to
thegreengroundingscrew.
2
When the wires have been connected
to the receptacle, insert the receptacle back
into the handy box. Secure the receptacle to
the handy box with two screws. Apply the
receptacle cover to the receptacle and secure
it with a screw. The power cord may now be
plugged into the receptacle.
3
To reduce the risk of electric shock,
this equipment has a grounding type plug that
has a third (grounding) pin. This plug will only
fit into a grounding type outlet. Do not change
the plug in any way.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
ElectricalContinued...
BATTERY BACK-UP
If the gate operator is already factory
equipped with battery run, only the Right/Left
Side switch and the Mode switch need to be
set. The Right/Left switch simply needs to be
set in the same position as the Right/Left
switch on the main control board. (See page
17 for correctly setting the Right/Left switch
on the control board) The Mode switch can be
set in either the Mode 1 or Mode 2 position.
This choice between Mode 1 or Mode 2
depends on how the installer or end user
would like the gate to behave when power is
lost.
Mode 1: Gate will continue to
operate when power is lost. When battery
power gets low, the gate will open and stay
open until power is restored. (Fail Secure)
Mode 2: Gate will open immediately
when power is lost and remain open until
power is restored. (Fail Safe)
BATTERY BACK-UP
If the gate operator did not come from
the factory equipped with battery run, field
installation of battery run is very simple. The
illustration at left shows additional wiring
required for battery run that is not part of the
standardwiring.
First turn power off to the gate
operator.
Disconnect the brown and red wires
from terminals 13 and 14 and insulate the
ends of the wires.
Secure the charger board to the main
control board by attaching to the 14 screw
terminals on the left side of the control board.
Connect a green wire from terminal 2
to terminal 15 of the control board.
Attach an orange wire from terminal
D of the charger board to terminal 18 of the
maincontrolboard.
Finally, attach a red wire from
terminal A to battery positive and a black wire
from terminal B to battery negative.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
ElectricalContinued...
OPEN INPUT: Any device that is used to open
the gate from a closed position is an open input device.
The device used must provide normally open contacts.
These normally open contacts are connected to
terminals 5 and 6. These open input terminals will
cause the gate operator to open and/or close if the
timer switch is in the OFF position. If the timer switch
is in the ON position, these open input terminals will
cause the gate operator to open and will hold the gate
open until the input is released and the auto close time
haselapsed.
1
2
3
4
412 HM
RADIO RECEIVER
CLOSE INPUT: Any device that is used to
close the gate is a close input device. The device used
must provide normally open contacts. These normally
open contacts are connected to terminals 9 and 10.
These close input terminals will cause the gate
operator to close the gate any time the gate is in a
non-closed position and can be used to override the
timer and close the gate prematurely.
GRY
GRY
LEFT/RIGHT SIDE
24 25 26 27
L
R
OPERATION
SWITCH
BLK
RED
TIMER
ADJUST
EDGE ALARM COM
RADIO
AUTO
CLOSE
TIMER
MORETIME
SWITCH1
RED
1
2
TIMERSWITCH
OFFON
COM
GRN
OPEN
PUSH BUTTONS,
ADJUST
SWITCH2
ORG
3
KEY SWITCHES, ETC.
INCREASE
SENSITIVITY
!
ADJUSTMENTS
4
N.O.
SAFETY
OPEN
CLOSE
ADJUST
SAFETY
OPEN
)
5
INCREASE
N.O.
N.O.
N.C.
)
)
)
MOTORPOWER
RELAY
15
6
-
PULSE
OPEN
PULSE OPEN
N.C.STOP
16
7
NOTUSED
8
17
18
19
20
21
22
23
-
N.C.
STOP
RELAYPOWER
9
+
CLOSE
N.O.
N.O.
CLOSE
RELAYCOIL
10
N.O.
STOP
)
START/STOP
RESITOR
N.O.STOP
11
12
13
14
)
REMOVE JUMPER
IF USING N.C. STOP
NOTUSED
+
RELAYCOIL
+
-
CIRCUIT
BOARD
POWER
SAFETY NOTES: Controls must be far enough from the
gate so that the user is prevented from coming in contact with the
gate while operating the controls. Controls intended to be used to
reset an operator after 2 sequential activations of the entrapment
protection device or devices must be located in the line of sight of
the gate. Outdoor or easily accessible controls shall have a
securityfeaturetopreventunauthorizeduse.
START/STOP
RESITOR
104680F
N.C. STOP INPUT: Any device that is used to stop the gate operator while it is running in the open or closed
direction is a stop input device. These stop input devices must provide normally closed contacts. To connect these normally
closed contacts, remove the stop jumper from terminals 8 and 9 and then connect the contacts to these same terminals 8
and 9.
N.O. STOP INPUT: This input functions identical to N.C. Stop with the exception that it requires normally open
contacts. These contacts are connected to terminals 9 and 11.
SAFETY INPUT: Any device that is used to open and/or hold open the gate while the gate is in a non-closed
position is a safety input device. The safety input device must provide normally open contacts. These contacts are connected
to terminals 4 and 6. This function is especially useful when the auto close timer is being used in preventing the gate from
accidentally closing on a vehicle.
PULSE OPEN INPUT: This input functions similarly to the standard open input with the exception that it will not
hold the gate open if the input remains present. This feature will add additional security to the gate operator system in the
event that there is a device that is stuck on. Pulse open is found at terminals 6 and 7.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Wiring Diagrams, Button Controls
z One button, two button and three button controls may be
connected individually or together as shown below. Most button
controls have a common "buss bar" which connects the common
terminals of all buttons together so that only one common wire
needs to be run back to the gate operator control board. If this is
not the case, the common terminals of each button may be
connected together with wire.
z Connect the common terminal or terminals (COM) of the push
button control to the Common (terminal 6) on the gate operator
control board. Connect the Open button NO terminal of the push
button control to Open (terminal 5) on the gate operator control
board. Connect the Close button NO terminal of the push button control to Close
(terminal 10) on the gate operator control board. If the stop button has normally
closed contacts, connect the Stop button NC terminal to Stop (terminal 9) and
remove the stop jumper that is on terminals 8 & 9. If the stop button has normally
open contacts, connect the Stop button terminal NO to the NO Stop (terminal 11)
on the gate operator control board.
z If more than one push button control is used on one gate operator, connect
wires from the Open, Close and Common in parallel to the control board. If the
stop button has normally closed, contacts connect the stop buttons in series to
the control board. If the stop buttons have normally open contacts, connect the
stop buttons in parallel to NO Stop (terminal 11) on the control board.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Fine Tuning
ADJUST TIMER
The gate operator is designed to
workdifferentlywhileopeningthenwhile
closing to optimize safety, so the direction of
the operator will need to be set. Setting the
operator direction is done by flipping the right/
left side switch located at the top of the
circuit board. For a left side installation flip
the switch to the left and for a right side
installation, flip the switch to the right (see
illustrationabove).
If it is desirable to have the gate
close automatically after the gate has
opened, flip the auto close timer switch to the
ON position. Adjust the amount of time the
gate stays open by turning the timer adjust-
ment pot counter clockwise for less time or
clockwise for more time. The range is roughly
0~45 seconds.
ADJUST SENSITIVITY
For protection of the over all system
there are two "sensitivity" adjustments on the
circuit board for the open and close direc-
tions. Turning the pots clockwise "increase"
will cause the gate to stop or reverse more
easily if there is an obstruction preventing the
gatefrommoving. Turningthepotscounter-
clockwise "decrease" will cause the gate to
push harder before it stops or reverses. If
adjusted properly, the sensitivity will cause
the gate to reverse if the gate meets an
obstruction. Additionally, if the gate again
meets an obstruction before reaching a limit,
the gate will stop, remain stopped, and will
sound an alarm until reset with an open input
at terminal 5. If no reset is given, the alarm
will sound for approximately 5 minutes. If
adjusted too sensitive the gate may stop or
reverseunderit'sownweight, withoutbeing
obstructed and the sensitivity will need to be
slightlydecreased.Temperature,wind,and
otherenvironmentalfactorsmayalsoeffect
the sensitivity, so the setting should be made
with these factors in mind. Before finalizing
an installation always test the sensitivity by
applying pressure against the gate while it is
moving to make sure it will stop or reverse.
NOTE:
Counter-Clockwise makes gate push harder.
Clockwise makes gate easier to stop.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Master/Second Wiring
SL920 MASTER/SECOND
z Connect 115 Volts AC to each SL920 gate operator. Connect the four Master/Second wires from the master circuit board
to the Second circuit board as shown below. Any operator can be used as either a master or a Second. Accessories can be
connected to the master or second operator.
z Switch the Auto Close Timer switch to the OFF position on the Second circuit board. The Auto Close Timer switch on the
master circuit board may be switched either ON if the timer function will be used or OFF if the timer function will not be used
but the Second timer must always be switched OFF.
z If the chain is wrapped around the sprockets in the same manner on each operator (both chains under or both chains over
the drive sprocket) set the Right/Left Side Operation switch on the master circuit board to be the opposite of the way it is set
on the Second circuit board. If the chain wrapped around the drive sprocket on the master operator is the opposite of the way
it is wrapped around on the Second operator then set the Right/Left Side Operation switches the same on both operators.
The Right/Left Side operation switch is located on the circuit board. If the operators are working backwards, the Right/Left
Side Operation switches on both operators must be switched. The simplest way to know if the operators are working back-
wards is to turn the Auto Close Timer switch on the master circuit board to ON and see whether the timer works when the
gate is open or closed. The timer should work only when the gate is open. Another way to know if the operators are working
backwards is to try the gate sensitivity by applying pressure against the gate while the gate is opening or closing. If pressure
is applied while the gate is opening it should stop. If pressure is applied while the gate is closing it should reverse and go
open. If the gate responds to pressure in a way that is opposite of this then switch the Right/Left Side Operation switch on
bothoperators.
MASTER
SECOND
18
Download from Www.Somanuals.com. All Manuals Search And Download.
SL920 WITH FULL SYSTEMS CAPABILITY
Wiring Diagram
19
Download from Www.Somanuals.com. All Manuals Search And Download.
SL920 WITH BATTERY BACK-UP
Wiring Diagrams
BREAKER
15 AMP
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety Edge and Warning Placard Installation
singedgesensor
e exact placement of
e contact sensors.
ore safety edge contact
ocated at the leading
e, and post mounted
utside of a vehicular
ate. When the contact
ed, it shall be located
nged so that the
etween the sensor and
is not subjected to
ge.
systems capability
e edge sensor is
minals 24 and 26 as
ure 2.
operatorisprovided
arning placards. The
e installed on each side
they are plainly visible.
be mounted using
ws through the six holes
placard.
ng signs and placards
where visible in the
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Options
If it is desired that the driveway
illuminate when the gate is activated, a light
delay timer may be installed. The light delay
timer will switch power on to the light for two
minutes, then shut power back off. The timer
relay is capable of switching up to 10 Amps
which will handle most flood or spot lights
available.Ageneralhook-updiagramforthe
light and timer is shown at left.
1
2
3
The standard auto close timer built
into the circuit board can be adjusted to
between 0 and 45 seconds. Some installa-
tions may require that the gate must stay
open for more than 45 seconds before it
automatically closes. The extended auto
close timer may be hooked up as shown at
left. This optional timer can be adjusted to
automatically close the gate after the gate
has been open between 1 and 100 minutes.
The extended timer will add time onto the
auto close timer already on the board. For
more control, reduce the timer adjustment on
the main control board to zero seconds and
make all adjustments with the extended auto
close timer knob.
For added safety, a warning alarm
may be installed in the gate operator to give
audible warning that the gate is in motion.
This will in some cases give extra time to get
out of the way of the moving gate. The
warning alarm is an ear piercing 120 decibel,
dual tone, piezo siren that operates on 12
Volt DC. To install the alarm, mount the siren
next to the circuit board and connect the
positive wire to terminal 12 (12VDC). Connect
the negative wire to limit switch 1 NC or limit
switch 2 NC for the alarm to sound in the
open or closed directions. Contact the
manufacturer for connecting the alarm to
sound in both directions. If the alarm is too
loud, the sound may be partially muffled by
applying tape over the two holes where the
sound comes out.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Options
For rear mount installation that are
limited on space for the gate to slide back
into, the space saver version is an excellent
alternative. There may be a property wall,
parking stall or other obstacle that reduces
the amount of space available, making it
difficult to mount the gate operator and still
have room for the gate to slide. The space
saver version of the gate operator places the
drive shaft externally so that the gate can
slide past the gate operator, picking up allot
of extra space. The external drive shaft can
be specified to be placed on either side of the
operator for left or right side installations or
can be easily converted in the field.
4
5
Installation of the space saver version
is very much like the rear mount installation
of the standard gate operator. The chain
makes a continuous loop going around the
drive sprocket on the operator and around the
idler sprocket on the post or wall. For the
case of the space saver, the external drive
sprocket allows the gate to slide past the
operator, makinginstallationpossiblewhere
there is only 4 inches of space left over after
the gate is open (see illustration at left).
23
Download from Www.Somanuals.com. All Manuals Search And Download.
OptionsContinued...
Gate Hardware Locator
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintenance and Safety
The SL920 is designed to be MAINTENANCE FREE. However,
foroptimumperformanceandsafety,thefollowingmaintenance
proceduresshouldbetaken.
Gate Sensitivity Adjustments
The most important thing to maintain on any gate is the safety equipment. As the gate becomes
older the amount of force necessary to move the gate will vary. When this happens, the gate sensitivity
adjustments may need to be readjusted. Check to see whether the sensitivity may need adjustment at
least once a month. Actuate the gate a few times and observe the amount of force that is needed to stop or
reverse the gate in both directions. This can be done very easily by standing beside the gate and applying
pressure with your hands against the gate while it is moving. Do not stand directly in the path of the
gate while doing this experiment. The gate should stop or reverse relatively easy. If it does not stop or
reverse easily or does not stop or reverse at all, make adjustments as shown on page 17 of Fine Tuning.
Control Devices
From time to time check to see whether all of the control devices that are connected to the
operator are functioning. This is especially important of anything that was installed in regards to safety.
Gate
Having a well maintained gate will ensure that the operator runs smoothly and safely. Occasionally
inspect the chain to see whether it is well lubricated and oil the chain if necessary. Use CHAIN AND
CABLE LUBE for best results (Available from the manufacturer). Check the wheels and grease them if
needed. Check the guide rollers and spray oil on their bearings. Check whether the gate appears to be
operating at normal speed to determine if the gate operator may be working harder than usual to overcome
frictionfromdamagedbearings.
IMPORTANT SAFETY INSTRUCTIONS
WARNING - To reduce the risk of injury or death:
1) READANDFOLLOWALLINSTRUCTIONS
2) Never let children operate or play with gate controls. Keep the remote control away from children.
3) Always keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE.
4) Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or stop when an object activates
the non-contact sensors. After adjusting the force or the limit of travel, retest the gate operator. Failure to adjust and retest
the gate operator properly can increase the risk of injury or death.
5) Use the emergency release only when the gate is not moving.
6) KEEP GATES PROPERLY MAINTAINED. Read the owner's manual. Have a qualified service person make repairs to
gatehardware.
7) The entrance is for vehicles only. Pedestrians must use separate entrance.
8) SAVETHESEINSTRUCTIONS.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
EXPLANATION OF VISUAL FEEDBACK LEDs
The SL920 Full Systems Capability circuit board has been equipped with Visual Feedback LEDs to simplify
installation and troubleshooting. These are small lights which are located directly beside the input terminals. These LEDs
give visual information to the installer or service technician indicating what commands are going into the circuit board from
devices such as limit switches or from peripheral devices such as radio receivers or safety loops. There are also two LEDs
which show output to the motor for both the opening and closing directions.
INPUT:
Limit Switch 1: This LED indicates that one of the normally open limit switches is pressed in and the gate is in the open
position.
Limit Switch 2: This LED indicates that one of the normally open limit switches is pressed in and the gate is in the closed
position.
Safety: This LED indicates that there is a closed contact between safety input terminal 4 and common.
Open: This LED indicates that there is a closed contact between open input terminal 5 and common.
Pulse Open: This LED indicates that there is a closed contact between Pulse Open input terminal 7 and common.
Stop: This LED indicates that there is a closed contact between stop input terminal 9 and common. Under normal operating
conditions this LED must be in the on condition in order for the system to function.
Close: This LED indicates that there is a closed contact between close input terminal 10 and common.
TRANSMITTER DOES NOT WORK
n Check the battery inside of the transmitter and/or try another transmitter. o Check to see which LEDs are
illuminated on the circuit board. For normal operating conditions the only LEDs that should be illuminated are the stop input
at terminal 9 and Limit Switch 1 input if the gate is in the fully open position or Limit Switch 2 input if the gate is in the fully
closed position. p If any of the input LEDs are illuminated on terminals 4, 5, 7 or 10, disconnect wires from that input
terminal that is illuminated until the LED is extinguished to determine which input device may be stuck in an on condition. q
If it is the radio receiver that appears to be stuck in an on condition, check all transmitters to see if any of them are stuck on.
r Make sure that there is power (10 to 16 VDC) to the receiver on terminals 8 and 12 and make sure that the circuit breaker
button is pressed in. s If a click is heard while the transmitter is being pressed and there is no response from the operator,
check all receiver connections. (See page 15.) t If there is still no response, see GATE WILL NOT OPEN OR CLOSE on
next page.
GATE TRAVELS TOO FAR OR NOT FAR ENOUGH
n Adjust the gate sensitivity (See page 17). If the gate sensitivity adjustment is too sensitive, the gate may stop in
mid-travel. o It may be necessary to lubricate any mechanical parts on the gate including wheels and rollers and clean the
track of any debris. p Check the limit switch input LEDs on terminals 1 and 3 to see if either one is illuminated. If one of the
limit switch input LEDs is illuminated and the gate has traveled too far or not far enough, this indicates that the limits of travel
may need adjustment. Adjust the limits of travel (See page 11). This adjustment may change slightly as the chain stretches
due to normal wear and it may change dramatically if the chain has been retightened or the limit plate is accidentally left not
engaged with the limit nuts. q If the limit nut has traveled past a limit switch, check the limit switch and all limit switch
connections. (See page 19 or 20). r Watch the stop input LED on terminal 9 while the gate operator is running and see if
the LED flickers or extinguishes. This may indicate a faulty stop input device or a poor connection between the stop input
terminal 9 and common. s If the stop input LED on terminal 9 flickers or extinguishes check all connections to the stop
inputdeviceand/orreplacefaultydevice.
GATE BEGINS TO OPEN OR CLOSE, THEN STOPS OR REVERSES
n Adjust the gate sensitivity (See page 17). If the gate sensitivity adjustment is too sensitive, the gate may stop in
mid-travel or reverse. o It may be necessary to lubricate any mechanical parts on the gate including wheels and rollers and
clean the track of any debris. p Watch the input LEDs on terminals 4, 5, 7 and 10 while the gate operator is running to see
if any of the LEDs flicker or illuminate. q If there is an input LED that flickers or illuminates while the gate is running,
disconnect the wires one at a time from that input terminal until the LED does not flicker or illuminate to determine which
input device may be activating. r If it is the radio receiver that appears to be stuck in the on condition, check all transmitters
to see if any of them may be stuck on. A stuck transmitter may cause the gate operator to reverse.
26
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
GATE WILL NOT OPEN OR CLOSE
Test the operator to find out whether the open input devices are functioning by following these steps. n If a remote
control is being used to open the gate, try another remote control or try using a push button if there is one installed. o If a
push button is being used try using another push button or a remote control. p If there is no push button installed the gate
may be operated by connecting a jumper wire to terminal 8 and momentarily touching it to terminal 5 or 7. q If the remote
controls are not working, see TRANSMITTER DOES NOT WORK on the previous page. r Check the manual release switch
to make sure it is in the operate (up) position. s Check to see which LEDs are illuminated on the circuit board. For normal
operating conditions the only LEDs that should be illuminated are the stop input at terminal 9 and Limit Switch 1 input if the
gate is in the fully open position or Limit Switch 2 input if the gate is in the fully closed position. t If any of the input LEDs
are illuminated on terminals 4, 5, 7 or 10, disconnect wires from that input terminal that is illuminated until the LED is
extinguished to determine which input device may be stuck. u If the stop input LED on terminal 9 is not illuminated, check
the stop input device if any are installed and all connections to the device. If no stop input device is installed make sure that
there is a jumper between terminals 8 and 9 and that it is securely fastened. v Check the circuit breaker button. If the circuit
breaker is tripped, press it back in. w Make sure there is power to the circuit board on terminals 13 and 14.
THE GATE WILL NOT STOP OR REVERSE WHEN IT MEETS AN OBSTRUCTION
n Adjust the gate sensitivity. The operator needs to be adjusted for more sensitivity. This is done by turning the
open and close gate sensitivity adjustments clockwise for more sensitivity. (See page 17).
GATE WILL NOT STAY CLOSED
n Make sure that the Right/Left Side operation switch is in the correct position (See page 17). If the Right/Left Side
operation switch is in the incorrect position, the auto close timer feature may be working in reverse and telling the gate
operator to open after the auto close time has elapsed. o Check to see if any input LEDs on terminals 4, 5 or 7 flicker or
illuminate when the gate gets to the closed position. p If any of the input LEDs flicker or illuminate on terminals 4, 5, or 7,
disconnect wires from that input terminal that is illuminated until the LED is extinguished to determine which input device
may be activating.
TIMER WILL NOT CLOSE THE GATE
n Make sure that the Right/Left Side operation switch is in the correct position (See page 17). If the Right/Left Side
operation switch is in the incorrect position, the auto close timer feature may be working in reverse and telling the gate
operator to open instead of close after the auto close time has elapsed. o Make sure the auto close timer switch is in the
ON position (See page 17). The auto close timer switch is located on the right edge of the circuit board. p Adjust the
amount of auto close time (See page 17). The auto close time may be set too high and is simply taking a long time to close.
Do not continue pressing the remote control or other open or safety input devices because each time an open or a safety
input is given the timer will reset and begin counting over.
OPERATOR RUNS IN ONLY ONE DIRECTION
n Check to see which LEDs are illuminated on the circuit board. For normal operating conditions the only LEDs that
should be illuminated are the stop input at terminal 9 and Limit Switch 1 input if the gate is in the fully open position or Limit
Switch 2 input if the gate is in the fully closed position. o If any of the input LEDs are illuminated on terminals 4, 5, 7 or 10,
disconnect wires from that input terminal that is illuminated until the LED is extinguished to determine which input device
may be stuck.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes
Other Commonly Used Open and Safety Devices
Be sure to read this entire manual before attempting to
perform any type of installation or service to the gate opener.
Once the installation has been completed, this installa-
tion and service manual becomes the property of the home
owner or end user and should be given to the new owner at that
time.
For a personal copy of this manual, please contact a
LiftMaster.
NOTE:
z All open and safety devices must have
normallyopencontacts.
z For Devices requiring power, refer to
the specific diagram for that particular
device.
28
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes
Be sure to read this entire manual before attempting to perform any type of installation or service to the gate opener.
Once the installation has been completed, this installation and service manual becomes the property of the home
owner or end user and should be given to the new owner at that time.
For a personal copy of this manual, please contact an LiftMaster distributor.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes
30
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes
31
Download from Www.Somanuals.com. All Manuals Search And Download.
HOW TO ORDER REPAIR PARTS
OUR LARGE SERVICE ORGANIZATION SPANSAMERICA
INSTALLATION AND SERVICE INFORMATION
AREAVAILABLE 6 DAYSAWEEK
CALL OUR TOLL FREE NUMBER - 1-800-528-2806
MONDAY Through FRIDAY 5:00 a.m. TO 6:00 p.m. (MST)
SATURDAY 7:00 a.m. TO 3:30 p.m. (MST)
WWW.LIFTMASTER.COM
WHEN ORDERING REPAIR PARTS
PLEASE SUPPLY THE FOLLOWING INFORMATION:
PART NUMBER DESCRIPTION MODEL NUMBER
ADDRESS ORDER TO:
THE CHAMBERLAIN GROUP, INC.
TECHNICAL SUPPORT CENTER
6020 South Country Club Rd
Tucson, AZ 85706
WARNING
To reduce the risk of injury use
this operator only with a sliding gate that is
no larger than 25 ft. in length
and no heavier than 500 lbs.
2003, The Chamberlain Group, Inc.
;
All rights Reserved
01-40332A
Download from Www.Somanuals.com. All Manuals Search And Download.
|