Preparing your garage door
WARNING
Before you begin:
To prevent possible SERIOUS INJURY or DEATH:
• Disable locks.
• ALWAYS call a trained door systems technician if
garage door binds, sticks, or is out of balance. An
unbalanced garage door may not reverse when
required.
• NEVER try to loosen, move or adjust garage door, door
springs, cables, pulleys, brackets or their hardware, all
of which are under EXTREME tension.
• Disable ALL locks and remove ALL ropes connected to
garage door BEFORE installing and operating garage
door opener to avoid entanglement.
• Remove any ropes connected to garage door.
• Complete the following test to make sure your
garage door is balanced and is not sticking or
binding:
1. Lift the door about halfway as shown. Release
the door. If balanced, it should stay in place,
supported entirely by its springs.
2. Raise and lower the door to see if there is any
binding or sticking.
If your door binds, sticks, or is out of balance, call a
trained door systems technician.
CAUTION
To prevent damage to garage door and opener:
• ALWAYS disable locks BEFORE installing and operating
the opener.
• ONLY operate garage door opener at 120V, 60 Hz to
avoid malfunction and damage.
Sectional Door
Tools needed
One-Piece Door
During assembly, installation and adjustment of the
opener, instructions will call for hand tools as
illustrated below.
Pencil
Carpenter's
2
1
Level (Optional)
Hack Saw
Tape Measure
Wire Cutters
Drill
Claw Hammer
3/16", 5/16" and
5/32" Drill Bits
Pliers
1/2" and 7/16" Sockets
and Wrench
Stepladder
Screwdriver
Adjustable End Wrench
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Planning
Identify the type and height of your garage door.
Survey your garage area to see if any of the
conditions below apply to your installation. Additional
materials may be required. You may find it helpful to
refer back to this page and the accompanying
illustrations as you proceed with the installation of
your opener.
• Do you have an access door in addition to the
garage door? If not, Model 7702CB Emergency
Key Release is required. See Accessories page.
• Look at the garage door where it meets the floor.
Any gap between the floor and the bottom of the
door must not exceed 1/4" (6 mm). Otherwise, the
safety reversal system may not work properly. See
Adjustment Step 3. Floor or door should be
repaired.
Depending on your requirements, there are several
installation steps which may call for materials or
hardware not included in the carton.
• Installation Step 1 – Look at the wall or ceiling
above the garage door. The header bracket must
be securely fastened to structural supports.
SECTIONAL DOOR INSTALLATIONS
• Do you have a steel, aluminum, fiberglass or glass
panel door? If so, horizontal and vertical
reinforcement is required (Installation Step 12).
• Installation Step 4 – Depending upon garage
construction, extension brackets or wood blocks
may be needed to install sensors.
• The opener should be installed above the center of
the door. If there is a torsion spring or center
bearing plate in the way of the header bracket, it
may be installed within 4 feet (1.2 m) to the left or
right of the door center. See Installation Steps 1
and 12.
• Installation Step 4 – Alternate floor mounting of the
safety reversing sensor will require hardware not
provided.
• Installation Step 6 – Do you have a finished ceiling
in your garage? If so, a support bracket and
additional fastening hardware may be required.
• If your door is more than 7 feet (2.1 m) high, see
rail extension kits listed on Accessories page.
FINISHED CEILING
SECTIONAL DOOR INSTALLATION
Support bracket &
fastening hardware
is required.
Horizontal and vertical reinforcement
is needed for lightweight garage doors
(fiberglass, steel, aluminum, door with
glass panels, etc.). See page 23 for details.
See page 19.
Rail
Header Wall
Motor unit
Extension
Spring
OR
Torsion
Spring
Wall-
mounted
Door
Access Door
CLOSED POSITION
Control
Vertical
Header
Bracket
Rail
Bracket
Rail Assembly
Centerline
of Garage
Door
Garage
Trolley
Door
Spring
Emergency
Release
Straight
Door
Arm
Rope & Handle
Safety Reversing
Sensor
Gap between floor
and bottom of door
Header
Wall
Curved
Door
must not exceed 1/4" (6 mm).
Safety Reversing Sensor
Door
Arm
Garage
Bracket
Door
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Planning (Continued)
WARNING
ONE-PIECE DOOR INSTALLATIONS
Without a properly working safety reversal system,
persons (particularly small children) could be
SERIOUSLY INJURED or KILLED by a closing garage
door.
• Generally, a one-piece door does not require
reinforcement. If your door is lightweight, refer to
the information relating to sectional doors in
Installation Step 12.
• The gap between the bottom of the garage door and
the floor MUST NOT exceed 1/4" (6 mm). Otherwise,
the safety reversal system may not work properly.
• The floor or the garage door MUST be repaired to
eliminate the gap.
• Depending on your door’s construction, you may
need additional mounting hardware for the door
bracket (Step 12).
FINISHED CEILING
ONE-PIECE DOOR WITHOUT TRACK
Support bracket
& fastening
hardware is required.
See page 19.
Header Wall
Motor unit
Rail
Wall-mounted
Door Control
Access
Door
CLOSED POSITION
Rail
Bracket
Rail Assembly
Header
Trolley
Bracket
Door
Bracket
Safety Reversing
Sensor
Emergency
Release
Gap between floor
and bottom of door must not exceed 1/4" (6 mm).
Rope & Handle
Safety Reversing Sensor
Straight Curved
Garage
Door
Door
Arm
Door
Arm
Header
Wall
ONE-PIECE DOOR WITH TRACK
CLOSED POSITION
Rail
Bracket
Header
Wall
Trolley
Access
Door
Header
Bracket
Curved
Door Arm
Rail Assembly
Door
Straight
Door
Garage
Door
Bracket
Arm
Emergency Release
Rope & Handle
Safety
Reversing
Sensor
Gap between floor
and bottom of door
Safety
must not exceed 1/4" (6 mm).
Reversing Sensor
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Carton Inventory
Your garage door opener is packaged in one carton
which contains the motor unit and all parts illustrated
below. Accessories will depend on the model
packing material. PARTS MAY BE STUCK IN THE
FOAM. Hardware for assembly and installation is
shown on the next page. Save the carton and packing
material until installation and adjustment is complete.
purchased. If anything is missing, carefully check the
Model PD462D
Model PD420D (1),
Model PD422D (2)
Model PD462D (2)
Remote Control
Transmitter Visor Clip
LOCK
LIGHT
®
®
SECURITY
SECURITY
®
SECURITY
Keyless Entry
3-Button
Single Button
Multi-Function
Remote Control
Remote Control
Door Control Panel
Rail Support
Sprocket
Coupling
Braces (4)
Motor Unit with a Light Lens
Rail
Assembly
2-Conductor Bell Wire
White & White/Red
Trolley
Straight Door
Arm Section
Header/Rail
Brackets
Y
L
N
O
T
N
U
O
M
G
N
I
IL
E
C
P
U
Curved Door
Arm Section
Header Bracket
Door Bracket
Hanging Brackets
Safety Labels
and
The Protector System®
Literature
(2) Safety Reversing Sensors
(1 Sending Eye and 1 Receiving Eye)
with attached 2-Conductor
Safety Reversing Sensor
Mounting Bracket (2)
White & White/Black Bell Wire
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Hardware Inventory
Separate all hardware and group as shown below for the assembly and installation procedures.
ASSEMBLY HARDWARE
Lock Nut
Bolt
Hex Bolt
1/4"-20x7/16 (12)
Sprocket Coupling Sleeve
1/4-20x1-3/4" (8)
1/4"-20x5/8" (4)
INSTALLATION HARDWARE
Ring
Carriage Bolt
Nut 5/16"-18 (6)
Handle
Wing Nut
Fastener (3)
1/4"-20x1/2" (2)
1/4"-20 (2)
Lag Screw
Hex Bolt
Insulated
5/16"-9x1-5/8" (2)
5/16"-18x7/8" (4)
Lock Washer 5/16" (6)
Staples (30)
Lag Screw
Screw
6ABx1-1/4" (2)
Screw 6-32x1" (2)
5/16"-18x1-7/8" (2)
Rope
Drywall Anchors (2)
Clevis Pin
Clevis Pin
Clevis Pin
5/16"x1" (1)
5/16"x2-3/4" (1)
5/16"x1-1/4" (1)
7
Download from Www.Somanuals.com. All Manuals Search And Download.
ASSEMBLY STEP 1
CAUTION
To prevent INJURY from pinching, keep hands and
fingers away from the joints while assembling the rail.
Assemble the Rail
To avoid installation difficulties, do not run the
garage door opener until instructed to do so.
1. Turn the opened rail carton upside down and
empty its contents onto a level work surface.
2. Unfold the rails, taking care to avoid kinking the
screw rod joint.
3. Rotate the rail sections so that the flat side is down
and the screw side is up for all three lengths. Keep
it clean and free of debris while you are working.
Straight
Door Arm
Remove
Extend
Cardboard Packing
End Rails
Outward
Rail
Support
Braces
Center
Rail
Trolley Rack
Rail Assembly
Hardware Bag
Chassis Assembly
Hardware Bag
Rail Assembly
Carton
Remove
Extend
Cardboard
Packing
End Rails
Outward
Sprocket End Rail
Rail
Sprocket
NOTE: During assembly, avoid pulling the rail section
housing the trolley rack away from the screw rod.
The rack is factory set about 9" (23 cm) from the end
of the screw rod to the center of the rack.
Rotate
If the plastic liner slides part way out during
assembly, simply push it back in.
Center Rail
Trolley Rack
Door End Rail
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Assemble the Rail (Continued)
4. Beginning with the sprocket end, straighten the
two rail sections so that the screw rod is in a
straight line at the joint. (Avoid handling the joint,
which may have sharp edges.)
5. Carefully slide the pins at the top edge of the rail
into the openings on the adjacent rail. It is
essential that the rail assembly be on a level
surface to achieve proper alignment and to
avoid damage to the pins.
6. Insert two 1/4"-20x1-3/4" bolts through the center
holes of a brace, and place its open length against
the rail at the joint, aligning the holes as shown.
Position another brace on the opposite side of the
rail over the bolts, add 1/4"-20 lock nuts, and hand
tighten. Insert two additional bolts and hand
tighten.
HARDWARE SHOWN ACTUAL SIZE
Bolt
Lock Nut
1/4"-20
1/4"-20x1-3/4" (8)
7. Keeping the rail straight and on a level surface,
grasp the screw rods on each side of the
remaining joint and pivot into a straight line.
Repeat steps 5 and 6.
8. With a 7/16" wrench, tighten bolts until snug,
beginning with the center holes. Do not
overtighten.
Sprocket End
(Back)
Rail
Support
Brace
Alignment
Hole
Rail Pin
Lock
Nuts
Slide end rail
toward center rail
Rail
Support
Brace
Bolts
1/4"-20x1-3/4"
Rail Pin
Lock
Nuts
Alignment
Hole
Center Rail
End
Rail
Alignment
Hole
Rail Pin
Center
Rail
Door End
(Front)
Bolts
1/4"-20x1-3/4"
Slide end rail
toward center rail
9
Download from Www.Somanuals.com. All Manuals Search And Download.
ASSEMBLY STEP 2
Fasten the Rail to the Motor Unit
and Install the Trolley
HARDWARE SHOWN ACTUAL SIZE
Lock Nut
1/4"-20
Hex Bolt
1/4"-20x5/8"
NOTE: To aid in assembly and installation, replace
the foam packing around the motor unit. Remove it
after Installation Step 4.
• Working on a level surface, align the rail assembly
with the motor unit, as shown.
• Slip the coupling over the rail sprocket.
• Slide the rail through the motor unit bracket until
the coupling fits securely over the motor unit
sprocket.
• Align the two bolt holes in the rail with those in the
motor unit bracket. Insert two 1/4"-20x5/8" hex
bolts and lock nuts. Tighten securely with a 7/16"
socket wrench.
Motor Unit
Sprocket
Slide the trolley onto and along the bottom of the
rail until it snaps firmly in place. Be certain to
install it facing correctly: the trolley release
arm must be horizontal (lock position), with its
arrow pointed away from the motor unit.
Motor Unit
Bracket
Lock Nuts
1/4"-20
Coupling
Rail
Sprocket
Rail
Assembly
Hex Bolts
1/4"-20x5/8"
Foam Packaging
Trolley
Arrow must point
toward garage door
Release arm
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Lock Nuts
1/4"-20
ASSEMBLY STEP 3
Attach the Rail Brackets
Rail
Brackets
• Align rail brackets to end of rail assembly, as
shown.
• Insert two 1/4"-20x5/8" hex bolts and lock nuts.
Tighten securely with a 7/16" socket.
Hex Bolts
1/4"-20x5/8
Rail
You have now finished assembling your garage
door opener. Please read the following warnings
before proceeding to the installation section.
HARDWARE SHOWN ACTUAL SIZE
Lock Nut
1/4"-20
Hex Bolt
1/4"-20x5/8"
INSTALLATION
IMPORTANT INSTALLATION INSTRUCTIONS
WARNING
To reduce the risk of SEVERE INJURY or DEATH:
1. READ AND FOLLOW ALL INSTALLATION WARNINGS
AND INSTRUCTIONS.
2. Install garage door opener only on properly balanced
and lubricated garage door. An improperly balanced
door may not reverse when required and could result in
SEVERE INJURY or DEATH.
3. All repairs to cables, spring assemblies and other
hardware MUST be made by a trained door systems
technician BEFORE installing opener.
4. Disable all locks and remove all ropes connected to
garage door BEFORE installing opener to avoid
entanglement.
5. Install garage door opener 7 feet (2.13 m) or more
above floor.
6. Mount emergency release handle 6 feet (1.83 m) above
floor.
7. NEVER connect garage door opener to power source
until instructed to do so.
8. NEVER wear watches, rings or loose clothing while
installing or servicing opener. They could be caught in
garage door or opener mechanisms.
9. Install wall-mounted garage door control:
• within sight of the garage door.
• out of reach of children at minimum height of 5 feet
(1.5 m).
• away from all moving parts of the door.
10. Place entrapment warning label on wall next to garage
door control.
11. Place manual release/safety reverse test label in plain
view on inside of garage door.
12. Upon completion of installation, test safety reversal
system. Door MUST reverse on contact with a
1-1/2" (3.8 cm) high object (or a 2x4 laid flat) on
the floor.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION STEP 1
Determine the Header Bracket
Location
Unfinished
Ceiling
OPTIONAL
CEILING
MOUNT
FOR
HEADER
BRACKET
WARNING
Header Wall
2x4
To prevent possible SERIOUS INJURY or DEATH:
Vertical Centerline
of Garage Door
• Header bracket MUST be RIGIDLY fastened to
structural support on header wall or ceiling, otherwise
garage door might not reverse when required. DO NOT
install header bracket over drywall.
2x4
Structural
Supports
• Concrete anchors MUST be used if mounting header
bracket or 2x4 into masonry.
• NEVER try to loosen, move or adjust garage door,
springs, cables, pulleys, brackets, or their hardware,
all of which are under EXTREME tension.
• ALWAYS call a trained door systems technician if
garage door binds, sticks, or is out of balance. An
unbalanced garage door might not reverse when
required.
Level
(optional)
Installation procedures vary according to garage door
types. Follow the instructions which apply to your
door.
1. Close the door and mark the inside vertical
centerline of the garage door.
2. Extend the line onto the header wall above the
door.
Header Wall
3" (7.5 cm)
You can fasten the header bracket within 4 feet
(1.22 m) of the left or right of the door center
only if a torsion spring or center bearing plate
is in the way; or you can attach it to the ceiling
(see page 13) when clearance is minimal. (It
may be mounted on the wall upside down if
necessary, to gain approximately 1/2" (1 cm).
Header Wall
Track
3" (7.5 cm)
Track
Highest Point
of Travel
Highest Point
of Travel
Door
Door
If you need to install the header bracket on a 2x4
(on wall or ceiling), use lag screws (not provided)
to securely fasten the 2x4 to structural supports as
shown here and on page 13.
One-piece door with horizontal track
Sectional door with curved track
3. Open your door to the highest point of travel as
shown. Draw an intersecting horizontal line on the
header wall above the high point:
• 3" (7.5 cm) above the high point for sectional
door and one-piece door with track.
Header Wall
8" (20 cm)
• 8" (20 cm) above the high point for one-piece
door without track.
Header Wall
8" (20 cm)
This height will provide travel clearance for the top
edge of the door.
Highest
Highest
Door
Point
Point
of Travel
NOTE: If the total number of inches exceeds the
height available in your garage, use the maximum
height possible, or refer to page 13 for ceiling
installation.
of Travel
Door
Jamb
Hardware
Pivot
One-piece door without track:
pivot hardware
One-piece door without track:
jamb hardware
12
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION STEP 2
Install the Header Bracket
Wall Mounting Holes
CEILING MOUNT ONLY
You can attach the header bracket either to the wall
above the garage door, or to the ceiling. Follow the
instructions which will work best for your particular
requirements. Do not install the header bracket
over drywall. If installing into masonry, use
concrete anchors (not provided).
The nail hole is for
positioning only.
You must use lag screws
to mount the header bracket.
UP
Optional
Wall Mounting Holes
WALL HEADER BRACKET INSTALLATION
• Center the bracket on the vertical centerline with
the bottom edge of the bracket on the horizontal
line as shown (with the arrow pointing toward the
ceiling).
Vertical
Centerline of
Garage Door
Header
Wall
Y
NL
O
T
Lag Screws
N
U
O
M
G
IN
L
I
E
C
5/16"-9x1-5/8"
UP
• Mark the vertical set of bracket holes (do not use
the holes designated for ceiling mount). Drill 3/16"
pilot holes and fasten the bracket securely to a
structural support with the hardware provided.
2x4
Header
Bracket
Structural
Support
Door Spring
HARDWARE SHOWN ACTUAL SIZE
Horizontal
Line
Garage
Door
Highest Point of
Vertical
Garage Door Travel
Centerline of
Garage Door
Lag Screw
5/16"-9x1-5/8"
CEILING HEADER BRACKET INSTALLATION
• Extend the vertical centerline onto the ceiling as
shown.
• Center the bracket on the vertical mark, no more
than 6" (15 cm) from the wall. Make sure the arrow
is pointing toward the wall. The bracket can be
mounted flush against the ceiling when clearance
is minimal.
– Finished Ceiling –
Vertical
• Mark the side holes. Drill 3/16" pilot holes and
fasten bracket securely to a structural support with
the hardware provided.
Centerline
Header
Bracket
of Garage Door
P
U
6" (15 cm)
Maximum
Door
Lag Screws
Spring
5/16"-9x1-5/8"
Ceiling Mounting Holes
CEILING MOUNT ONLY
UP
Header Wall
The nail hole is for
positioning only.
You must use lag screws
to mount the header bracket.
Garage Door
Vertical
Centerline
of Garage Door
13
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION STEP 3
Attach the Rail to the Header
Bracket
• Position the opener on the garage floor below the
header bracket. Use packing material as a
protective base. NOTE: If the door spring is in the
way you’ll need help. Have someone hold the
opener securely on a temporary support to allow
the rail to clear the spring.
• Position the rail bracket against the header
bracket.
• Align the bracket holes and join with a clevis pin
5/16"x2-3/4" as shown.
• Insert a ring fastener to secure.
Header Wall
Header Bracket
Rail Bracket
Ring Fastener
Header Bracket
Rail
Clevis Pin
5/16"x2-3/4"
Rail
Bracket
Rail
Garage
Door
Opener Carton or
Temporary
Support
HARDWARE SHOWN ACTUAL SIZE
Clevis Pin
5/16"x2-3/4"
Ring Fastener
14
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION STEP 4
WARNING
®
Install The Protector System
Be sure power is not connected to the garage door
opener BEFORE installing the safety reversing sensor.
The safety reversing sensor must be connected
and aligned correctly before the garage door
opener will move in the down direction.
To prevent SERIOUS INJURY or DEATH from a closing
garage door:
• Correctly connect and align the safety reversing
sensor. This required safety device MUST NOT be
disabled.
IMPORTANT INFORMATION ABOUT
THE SAFETY REVERSING SENSOR
• Install the safety reversing sensor so beam is NO
HIGHER than 6" (15 cm) above garage floor.
When properly connected and aligned, the sensor
will detect an obstacle in the path of its electronic
beam. The sending eye (with an amber indicator
light) transmits an invisible light beam to the
receiving eye (with a green indicator light). If an
obstruction breaks the light beam while the door is
closing, the door will stop and reverse to full open
position, and the opener lights will flash 10 times.
If it is necessary to mount the units on the wall, the
brackets must be securely fastened to a solid
surface such as the wall framing. Extension brackets
(see accessories) are available if needed. If
installing in masonry construction, add a piece of
wood at each location to avoid drilling extra holes in
masonry if repositioning is necessary.
The units must be installed inside the garage so that
the sending and receiving eyes face each other
across the door, no more than 6" (15 cm) above the
floor. Either can be installed on the left or right of the
door as long as the sun never shines directly into the
receiving eye lens.
The invisible light beam path must be unobstructed.
No part of the garage door (or door tracks, springs,
hinges, rollers or other hardware) may interrupt the
beam while the door is closing.
The mounting brackets are designed to clip onto the
track of sectional garage doors without additional
hardware.
Safety Reversing Sensor
6" (15 cm) max. above floor
Safety Reversing Sensor
6" (15 cm) max. above floor
Invisible Light Beam
Protection Area
Facing the door from inside the garage
15
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLING THE BRACKETS
Be sure power to the opener is disconnected.
Install and align the brackets so the sensors will face
each other across the garage door, with the beam no
higher than 6" (15 cm) above the floor. They may be
installed in one of three ways, as follows.
DOOR TRACK MOUNT (RIGHT SIDE)
Figure 1
Door
Track
Lip
Garage door track installation (preferred):
Indicator
Light
• Slip the curved arms over the rounded edge of
each door track, with the curved arms facing the
door. Snap into place against the side of the track.
It should lie flush, with the lip hugging the back
edge of the track, as shown in Figure 1.
Sensor
Bracket
Lens
If your door track will not support the bracket
securely, wall installation is recommended.
Wall installation (Figure 2 & 3):
• Place the bracket against the wall with curved
arms facing the door. Be sure there is enough
clearance for the sensor beam to be unobstructed.
WALL MOUNT (RIGHT SIDE)
Inside
arage
G
Fasten Wood Block to Wall with
Figure 2
l
al
W
Lag Screws (Not Provided)
Indicator
• If additional depth is needed, an extension bracket
(See Accessories) or wood blocks can be used.
Sensor
Bracket
Light
• Use bracket mounting holes as a template to
locate and drill (2) 3/16" diameter pilot holes on
the wall at each side of the door, no higher than 6"
(15 cm) above the floor.
Lag Screws
(Not Provided)
Lens
• Attach brackets to wall with lag screws
(Not provided).
• If using extension brackets or wood blocks, adjust
right and left assemblies to the same distance out
from the mounting surface. Make sure all door
hardware obstructions are cleared.
WALL MOUNT (RIGHT SIDE)
Figure 3
Inside
Extension
arage
G
l
Bracket
al
W
(See Accessories)
Floor installation (Figure 4):
(Provided with
• Use wood blocks or extension brackets (See
Accessories) to elevate sensor brackets so the
lenses will be no higher than 6" (15 cm) above the
floor.
Extension Bracket)
• Carefully measure and place right and left
assemblies at the same distance out from the wall.
Be sure all door hardware obstructions are
cleared.
Sensor
Bracket
Indicator
(Provided with
• Fasten to the floor with concrete anchors as
shown.
Extension
Bracket)
Light
Lens
FLOOR MOUNT (RIGHT SIDE)
Figure 4
HARDWARE SHOWN ACTUAL SIZE
Attach with
Concrete Anchors
(Not Provided)
Inside
arage
G
l
al
W
Lens
Indicator
Light
Carriage Bolt
1/4"-20x1/2"
Wing Nut
1/4"-20
Staples
Sensor
Bracket
16
Download from Www.Somanuals.com. All Manuals Search And Download.
MOUNTING AND WIRING THE SAFETY
REVERSING SENSORS
Figure 5
Wing Nut
1/4"-20
• Slide a 1/4"-20x1/2" carriage bolt head into the slot
on each sensor. Use wing nuts to fasten sensors
to brackets, with lenses pointing toward each other
across the door. Be sure the lens is not obstructed
by a bracket extension. See Figure 5.
Carriage Bolt
1/4"-20x1/2"
Lens
• Finger tighten the wing nuts.
Recommended Wire Routing
1. Using insulated staples, run the wires from both
sensors to the rail at the door header
(see Figure 6).
HARDWARE SHOWN ACTUAL SIZE
2. Cross and twist the two wires where they meet
the rail (see Figure 6, Illustration A). Run the wires
inside the channels at the top of the rail, along
each side, to the motor unit. Do not use the lower
(trolley) channels. Use a screwdriver tip to tuck
the wires snugly into the channels.
Carriage Bolt
1/4"-20x1/2"
Wing Nut
1/4"-20
Staples
NOTE: If your access door is near the garage
door, you may choose to install the door control at
this time and run the door control wire along the
rail with the sensor wires. Use one rail channel for
the door control wire and the other channel for
both sensor wires. If you choose this option, follow
instructions 1-3 on page 20 now.
3. Pull wires taut across the top of the chassis and
insert into the opening above the terminal block
(see Figure 6, Illustration B). You will complete the
wiring in Installation Step 7.
A
Header
Wall
Sensor
Wire
Twist
Sensor
Wires
Wire
Header
Bracket
Figure 6
Rail
Channel
1. Run wires from sensors to end of rail
at the door header. Cross & twist here to
help contain wires in channels on top of rail.
Bell Wire
2. Run wires along channels
to motor unit. Use screwdrive blade
to tuck snugly into channels.
B
3. Pull wires taut across top of chassis
and insert into opening above
terminal block.
Safety Reversing
Invisible Light Beam
Protection Area
Sensor
Safety Reversing
Sensor
17
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION STEP 5
CAUTION
To prevent damage to garage door, rest garage door
opener rail on 2x4 placed on top section of door.
Position the Opener
Follow instructions which apply to your door type as
illustrated.
SECTIONAL DOOR OR ONE-PIECE DOOR WITH
TRACK
A 2x4 laid flat is convenient for setting an ideal
door-to-rail distance.
• Remove foam packaging.
• Raise the opener onto a stepladder. You will need
help at this point if the ladder is not tall enough.
2x4 is used to determine
the correct mounting
height from ceiling.
• Open the door all the way and place a 2x4 laid flat
on the top section beneath the rail.
Door
• If the top section or panel hits the trolley when you
raise the door, pull down on the trolley release arm
to disconnect inner and outer sections. Slide the
outer trolley toward the motor unit. The trolley can
remain disconnected until Installation Step 13
is completed.
Trolley
Release Arm
ENGAGED
RELEASED
ONE-PIECE DOOR WITHOUT TRACK
Header
Bracket
A 2x4 on its side is convenient for setting an ideal
door-to-rail distance.
Top of Door
• Remove foam packaging.
• Raise the opener onto a stepladder. You will need
help at this point if the ladder is not tall enough.
2x4 is used to determine
the correct mounting height
from ceiling.
• Open the door all the way and place a 2x4 on its
side on the top section of the door beneath the rail.
• The top of the door should be level with the top of
the motor unit. Do not position the opener more
than 4" (10 cm) above this point.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION STEP 6
WARNING
To avoid possible SERIOUS INJURY from a falling
garage door opener, fasten it SECURELY to structural
supports of the garage. Concrete anchors MUST be used
if installing any brackets into masonry.
Hang the Opener
Three representative installations are shown. Yours
may be different. Hanging brackets should be angled
(Figure 1) to provide rigid support. On finished
ceilings (Figure 2), attach a sturdy metal bracket to
structural supports before installing the opener. This
bracket and fastening hardware are not provided
(see accessories).
Structural
Supports
Figure 1
Existing brackets from a previous installation may be
fastened to the sides of the motor unit as in
Figures 1 and 2, or to the mounting tabs as shown in
Figure 3. Then continue with step 5 below.
Lag Screws
5/16"- 18x1-7/8"
Measure
Distance
1. Measure the distance from each side of the motor
unit to the structural support.
Hex Bolt
5/16"-18x7/8"
Lock Washers 5/16"
Nuts 5/16"-18
2. Cut both pieces of the hanging bracket to required
lengths.
3. Drill 3/16" pilot holes in the structural supports.
4. Attach one end of each bracket to a support with
5/16"-18x1-7/8" lag screws.
Preferred range of
bracket placement
5. Fasten the opener to the hanging brackets with
5/16"-18x7/8" hex bolts, lock washers and nuts.
If you wish to utilize the two center mounting tabs,
you must triangulate the vertical brackets for
additional stability. See Figure 3.
Figure 2
— FINISHED CEILING —
Hidden
Support
6. Check to make sure the rail is centered over the
door (or in line with the header bracket if the
bracket is not centered above the door).
Lag Screws
5/16"-18x1-7/8"
Bracket
(Not Provided)
(Not Provided)
7. Remove the 2x4. Operate the door manually. If
the door hits the rail, raise the header bracket.
Bolt 5/16"-18x7/8"
Lock Washer 5/16"
Nut 5/16"-18
NOTE: DO NOT connect power to opener at this
time.
Bolt 5/16"-18x7/8"
Lock Washer 5/16"
Nut 5/16"-18
HARDWARE SHOWN ACTUAL SIZE
Preferred range of
bracket placement
Figure 3
Lag Screw 5/16"-18x1-7/8"
Existing Brackets
Top Mounting Tabs
Hex Bolt
5/16"-18x7/8"
Lock Washer 5/16"
Nut 5/16"-18
Bracket
(Provided)
Utilizing existing installation
19
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION STEP 7
WARNING
Install the Door Control
To prevent possible SERIOUS INJURY or DEATH from
electrocution:
Locate door control within sight of door at a minimum
height of 5 feet (1.5 m) where small children cannot
reach, and away from moving parts of door and door
hardware. The installation surface must be smooth
and flat. If installing into drywall (Figure 1), drill 5/32"
holes and use anchors provided. For pre-wired
installations (as in new home construction), it may be
mounted to a single gang box (Figure 2). NOTE: After
installation, a green or amber indicator light behind
the cover will indicate proper connection. If not lit, the
Lock and Light features will not function (reverse wires
to correct).
• Be sure power is not connected BEFORE installing door
control.
• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a
closing garage door:
• Install door control within sight of garage door, out of
reach of children at a minimum height of 5 feet
(1.52 m), and away from all moving parts of door.
• NEVER permit children to operate or play with door
control push buttons or remote control transmitters.
• Activate door ONLY when it can be seen clearly, is properly
adjusted, and there are no obstructions to door travel.
• ALWAYS keep garage door in sight until completely
closed. NEVER permit anyone to cross path of closing
garage door.
1. Strip 7/16" (11 mm) of insulation from one end of
bell wire and connect to the two screw terminals on
back of door control by color: white wire to WHT
and white/red wire to the RED (Figure 3).
2. Remove cover by gently prying on a side corner
near the top of the cover with a small flat head
screwdriver (Figure 4). Fasten with 6ABx1-1/4" self-
tapping screws (drywall installation) or 6-32x1"
machine screws (into gang box) as follows:
HARDWARE SHOWN ACTUAL SIZE
Insulated
Staples
Screw 6ABx1-1/4"
Control Panel (std installation)
• Drill and install bottom screw, allowing 1/8" (3 mm)
to protrude above wall surface.
• Position bottom of door control on screw head and
slide down to secure. Adjust screw for snug fit.
Screw 6-32x1"
Drywall Anchors
Control Panel (pre-wired)
• Install top screw with care to avoid cracking plastic
housing. Do not overtighten.
• Insert bottom tabs and snap on cover.
PRE-WIRED
STANDARD
Figure 1
Figure 2
INSTALLATION
INSTALLATION
NOTE: The push bar may stick if the door control is
not mounted on a smooth surface. If a click is not
heard when pressing the push bar, loosen the two
mounting screws or relocate the door control to a
smoother surface.
LOCK
LIGHT
3. (Standard installation only) Run bell wire up wall
and across ceiling to motor unit. Use insulated
staples to secure wire in several places. Do not
pierce wire with a staple, creating a short or open
circuit. If your access door is near the garage door,
you may run this wire with the Safety Reversing
Sensor wires along the top of the rail. See page 17.
4. Insert all wires through the opening on top of motor
unit above the terminal block on the back panel
(Figure 4).
LOCK
LIGH
T
To Replace
24 Volt
Insert Bottom Tabs First
To Replace
Bell Wire
Insert Bottom Tabs First
Figure 3
Figure 4
To
Sensors
MULTI-FUNCTION
WALL CONTROL PANEL
To
Door
Control
Terminal
Screws
5. Strip 7/16" (11 mm) of insulation from each set of bell
wires. Connect bell wires to the quick-connect
terminals as follows: white to white and white/red to
red; white to white and white/black to grey (Figure 5).
Bell
Wire
RED WHT
1
2
Bottom
Mounting Hole
Quick-
Connect
Terminal
NOTE: When connecting multiple door controls to the
opener, twist same color wires together. Insert wires
into quick-connect holes: white to white and red/white
to red.
6. Use tacks or staples to permanently attach
entrapment warning label to wall near door control,
and manual release/safety reverse test label in a
prominent location on inside of garage door.
To release wire, push in
tab with screwdriver tip
Door Control
Connections
Safety Sensor
Connections
NOTE: DO NOT connect the power and operate the
opener at this time. The trolley will travel to the full open
position but will not return to the close position until the
sensor beam is connected and properly aligned.
Red White Grey
7/16" (11 mm)
Strip wire 7/16" (11 mm)
20
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION STEP 8
CAUTION
Install the Lights and Lens
To prevent possible OVERHEATING of the endpanel or
light socket:
• Install a 100 watt maximum light bulb in each
socket. Light bulb size is A19, standard neck only.
The lights will turn ON and remain lit for
approximately 4-1/2 minutes when power is
connected. Then the lights will turn OFF.
• DO NOT use short neck or specialty light bulbs.
• DO NOT use halogen bulbs. Use ONLY incandescent.
To prevent damage to the opener:
• DO NOT use bulbs larger than 100W.
• ONLY use A19 size bulbs.
• Insert bottom lens tabs into slots on chassis. Tilt
towards chassis to engage top tabs, then drop
down gently into place. (See illustration.)
Top Lens Tab
Lens
• To remove, depress both top lens tabs. Tilt lens
slightly outward and down, then pull out to clear
bulbs. Use care to avoid snapping off bottom lens
tabs.
Bottom
Lens Tab
• Use A19, standard neck garage door opener bulbs
for replacement.
Top
Chassis
Slot
NOTE: Use only standard light bulbs. The use of
short neck or speciality light bulbs may overheat the
endpanel or light socket.
Bottom
Chassis Slots
Top
Lens Tab
Top
Chassis Slot
Lens
Bottom
Insert Bottom
Chassis Slot
Lens Tabs First
INSTALLATION STEP 9
Attach the Emergency Release
Rope and Handle
WARNING
To prevent possible SERIOUS INJURY or DEATH from a
falling garage door:
• If possible, use emergency release handle to disengage
trolley ONLY when garage door is CLOSED. Weak or
broken springs or unbalanced door could result in an
open door falling rapidly and/or unexpectedly.
• NEVER use emergency release handle unless garage
doorway is clear of persons and obstructions.
• Thread one end of the rope through the hole in the
top of the red handle so “NOTICE” reads right side
up as shown. Secure with an overhand knot at
least 1" (2.5 cm) from the end of the rope to
prevent slipping.
• Thread the other end of the rope through the hole
in the release arm of the outer trolley.
• NEVER use handle to pull door open or closed. If rope
knot becomes untied, you could fall.
• Adjust rope length so the handle is 6 feet (1.83 m)
above the floor. Ensure that the rope and handle
clear the tops of all vehicles to avoid
Trolley
entanglement. Secure with an overhand knot.
NOTE: If it is necessary to cut the rope, heat seal
the cut end with a match or lighter to prevent
unraveling.
Trolley
Release Arm
N
Overhand
Knot
O
TIC
E
Emergency
Release Handle
21
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION STEP 10
WARNING
Electrical Requirements
To prevent possible SERIOUS INJURY or DEATH from
electrocution or fire:
To avoid installation difficulties, do not run the
opener until Step 9 below.
• Be sure power is not connected to the opener, and
disconnect power to circuit BEFORE removing cover to
establish permanent wiring connection.
• Garage door installation and wiring MUST be in
compliance with all local electrical and building codes.
• NEVER use an extension cord, 2-wire adapter, or
change plug in any way to make it fit outlet. Be sure
the opener is grounded.
To reduce the risk of electric shock, your garage door
opener has a grounding type plug with a third
grounding pin. This plug will only fit into a grounding
type outlet. If the plug doesn't fit into the outlet you
have, contact a qualified electrician to install the
proper outlet.
PERMANENT WIRING
CONNECTION
RIGHT
WRONG
If permanent wiring is required by your local
code, refer to the following procedure.
Ground Tab
To make a permanent connection through the 7/8"
hole in the top of the motor unit:
Green
Ground Screw
Black
• Remove the motor unit cover screws and set the
cover aside.
Ground Wire
Wire
• Remove the attached 3-prong cord.
• Connect the black (line) wire to the screw on the
brass terminal; the white (neutral) wire to the
screw on the silver terminal; and the ground wire
to the green ground screw. The opener must be
grounded.
Black Wire
White Wire
• Reinstall the cover.
To avoid installation difficulties, do not run the
opener until Step 9 below.
INSTALLATION STEP 11
Complete the Safety Reversing
Sensor Installation
TROUBLESHOOTING THE SAFETY REVERSING
SENSORS
1. If the sending eye indicator light does not glow
steadily after installation, check for:
ALIGNING THE SAFETY REVERSING SENSORS
• Electric power to the opener.
• A short in the white or white/black wires. These
can occur at staples, or at opener connections.
• Incorrect wiring between sensors and opener.
• A broken wire.
• Plug in the opener. The indicator lights in both the
sending and receiving eyes will glow steadily if
wiring connections and alignment are correct.
The sending eye amber indicator light will glow
regardless of alignment or obstruction. If the green
indicator light in the receiving eye is off, dim, or
flickering (and the invisible light beam path is not
obstructed), alignment is required:
2. If the sending eye indicator light glows steadily but
the receiving eye indicator light doesn't:
• Check alignment.
• Check for an open wire to the receiving eye.
• Loosen the sending eye wing nut and readjust,
aiming directly at the receiving eye. Lock in place.
3. If the receiving eye indicator light is dim, realign
either sensor.
• Loosen the receiving eye wing nut and adjust the
sensor until it receives the sender’s beam. When
the green indicator light glows steadily, tighten the
wing nut.
NOTE: When the invisible beam path is obstructed
or misaligned while the door is closing, the door will
reverse. If the door is already open, it will not close.
The opener lights will flash 10 times. (See page 15.)
22
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION STEP 12
CAUTION
Fasten the Door Bracket
Fiberglass, aluminum or lightweight steel garage doors
WILL REQUIRE reinforcement BEFORE installation of
door bracket. Contact your door manufacturer for
reinforcement kit.
Follow instructions which apply to your door type
as illustrated below or on the following page.
A horizontal reinforcement brace should be long
enough to be secured to two or three vertical
supports. A vertical reinforcement brace should
cover the height of the top panel.
Header
Bracket
Figure 1 shows one piece of angle iron as the
horizontal brace. For the vertical brace, 2 pieces of
angle iron are used to create a U-shaped support.
The best solution is to check with your garage door
manufacturer for an opener installation door
reinforcement kit.
Door
Bracket
Location
NOTE: Many door reinforcement kits provide for
direct attachment of the clevis pin and door arm. In
this case you will not need the door bracket; proceed
to Step 13.
HORIZONTAL AND VERTICAL
REINFORCEMENT IS NEEDED
FOR LIGHTWEIGHT GARAGE
DOORS (FIBERGLASS,
ALUMINUM, STEEL, DOORS
WITH GLASS PANEL, ETC.).
(NOT PROVIDED)
Vertical
Centerline
of Garage
Door
SECTIONAL DOORS
1. Center the door bracket on the previously marked
vertical centerline used for the header bracket
installation. Note correct UP placement, as
stamped inside the bracket.
Figure 1
2. Position the top edge of the bracket 2"-4"
(5-10 cm) below the top edge of the door, OR
directly below any structural support across the top
of the door.
Vertical
Reinforcement
(Not Provided)
Vertical
Vertical
Reinforcement
Centerline
of Garage Door
3. Mark, drill holes and install as follows, depending
on your door’s construction:
Vertical
Bolt
Centerline
5/16"-18x2"
of Garage Door
Metal or light weight doors using a vertical angle
iron brace between the door panel support and
the door bracket:
UP
Door
UP
Bracket
Lock Washer
Door
• Drill 3/16" fastening holes. Secure the door bracket
using the two 1/4"-14x5/8" self-threading screws.
(Figure 2A)
5/16"
Nut
Bracket
5/16"-18
Self-Threading
Screw
Figure 2B
1/4"-14x5/8"
• Alternately, use two 5/16" bolts, lock washers and
nuts (not provided). (Figure 2B)
Figure 2A
Inside Edge
(Not Provided)
Metal, insulated or light weight factory reinforced
doors:
of Door or
Reinforcement Board
Bolt
• Drill 3/16" fastening holes. Secure the door bracket
using the self-threading screws (Figure 3).
5/16"x2"
UP
Wood Doors:
Vertical
• Use top and bottom or side to side door bracket
holes. Drill 5/16" holes through the door and
secure bracket with 5/16"x2" carriage bolts, lock
washers and nuts (not provided). (Figure 4)
Centerline
of Garage Door
Vertical
Centerline
of Garage
Door
UP
NOTE: The 1/4"-14x5/8"
self-threading screws are
not intended for use on
HARDWARE
SHOWN
ACTUAL SIZE
Self-Threading
Screw
Figure 4
1/4"-14x5/8"
wood doors.
Self-Threading
Screw
Figure 3
1/4"-14x5/8"
23
Download from Www.Somanuals.com. All Manuals Search And Download.
ONE-PIECE DOORS
Please read and comply with the warnings and
reinforcement instructions on the previous page.
They apply to one-piece doors also.
• Center the door bracket on the top of the door, in
line with the header bracket as shown. Mark either
the left and right, or the top and bottom holes.
HARDWARE SHOWN
ACTUAL SIZE
• Metal Doors: Drill 3/16" pilot holes and fasten the
bracket with the 1/4"-14x5/8" self-threading screws
provided.
• Wood Doors: Drill 5/16" holes and use 5/16"x2"
carriage bolts, lock washers and nuts (not
provided) or 5/16"x1-1/2" lag screws (not provided)
depending on your installation needs.
Self-Threading Screw
1/4"-14x5/8"
NOTE: The door bracket may be installed on the top
edge of the door if required for your installation.
(Refer to the dotted line optional placement
drawing.)
Self-Threading
Screw
1/4"-14x5/8"
Door
Top of Door
Header Wall
Finished Ceiling
Bracket
(Inside
2x4 Support
Garage)
Top Edge
of Door
Header
Bracket
Optional
Placement
Door
Bracket
METAL DOOR
Optional
HORIZONTAL AND VERTICAL
REINFORCEMENT IS NEEDED
FOR LIGHTWEIGHT GARAGE
DOORS (FIBERGLASS,
Placement
of Door
Nut
Lock
5/16"-18
Bracket
Washer
5/16"
ALUMINUM, STEEL, DOORS
WITH GLASS PANEL, ETC.).
(NOT PROVIDED)
Top of Door
Door
Vertical
(Inside
Bracket
Centerline of
Garage Door
Garage)
Top Edge
of Door
Optional
Placement
Carriage Bolt
5/16"x2"
(Not Provided)
WOOD DOOR
For a door with no exposed framing,
or for the optional installation, use
lag screws 5/16"x1-1/2" (Not Provided)
to fasten door bracket.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION STEP 13
Connect Door Arm to Trolley
Inner
Trolley
Outer
Trolley
Follow instructions which apply to your door type as
illustrated below and on the following page.
SECTIONAL DOORS ONLY
Ring
Clevis Pin
5/16"x1"
Fastener
• Make sure garage door is fully closed. Pull the
emergency release handle to disconnect the outer
trolley from the inner trolley. Slide the outer trolley
back (away from the door) about 2" (5 cm) as
shown in Figures 1, 2 and 3.
Straight
Door Arm
Emergency
Release
Handle
Door
Bracket
• Figure 1:
– Fasten straight door arm section to outer trolley
with the 5/16"x1" clevis pin. Secure the
connection with a ring fastener.
Curved Door Arm
Clevis Pin
5/16"x1-1/4"
– Fasten curved section to the door bracket in the
same way, using the 5/16"x1-1/4" clevis pin.
Figure 1
• Figure 2:
– Bring arm sections together. Find two pairs of
holes that line up and join sections. Select holes
as far apart as possible to increase door arm
rigidity.
• Figure 3, Hole alignment alternative:
Lock
Washers
5/16"
– If holes in curved arm are above holes in straight
arm, disconnect straight arm. Cut about 6"
(15 cm) from the solid end. Reconnect to trolley
with cut end down as shown.
Nuts
5/16"-18
– Bring arm sections together.
– Find two pairs of holes that line up and join with
bolts, lock washers and nuts.
Bolts
5/16"-18x7/8"
• Pull the emergency release handle toward the
opener at a 45° angle so that the trolley release
arm is horizontal. Proceed to Adjustment Step 1,
page 27. Trolley will re-engage automatically when
opener is operated.
Door Bracket
Figure 2
HARDWARE SHOWN ACTUAL SIZE
Lock
Washers
5/16"
Nut 5/16"-18
Lock Washer 5/16" Ring Fastener
Clevis Pin
Nuts
5/16"-18
Hex Bolt
Clevis Pin
5/16"x1" (Trolley)
5/16"x1-1/4" (Door Bracket) 5/16"-18x7/8"
Bolts
5/16"-18x7/8"
Cut this end
Figure 3
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Door
ALL ONE-PIECE DOORS
Ring
Bracket
1. Assemble the door arm, Figure 4:
Fastener
Nuts
Lock
5/16"-18
• Fasten the straight and curved door arm sections
together to the longest possible length (with a 2
or 3 hole overlap).
Washers
5/16"
Clevis Pin
Straight
Arm
5/16"x1-1/4"
• With the door closed, connect the straight door
arm section to the door bracket with the
5/16"x1-1/4" clevis pin.
Bolts
Curved
Figure 4
5/16"-18x7/8"
Door Arm
• Secure with a ring fastener.
- Press the Door Control push button. The trolley
will travel to the fully closed position.
2. Adjustment procedures, Figure 5:
• On one-piece doors, before connecting the door
arm to the trolley, the travel limits must be
adjusted. Limit adjustment screws are located on
the left side panel as shown on page 27. Follow
adjustment procedures below.
- Manually close the door and lift the door arm to
the trolley. The arm should touch the trolley just
ahead of the door arm connector hole. Refer to
the fully closed trolley/door arm positions in the
illustration. If the arm is behind the connector
hole, adjust the limit further. One full turn equals
2" (5 cm) of trolley travel.
• Open door adjustment: decrease UP
travel limit
- Turn the UP limit adjustment screw
counter-clockwise 4 turns.
3. Connect the door arm to the trolley:
• Close the door and join the curved arm to the
connector hole in the trolley with the remaining
clevis pin. It may be necessary to lift the door
slightly to make the connection.
- Press the Door Control push button. The trolley
will travel to the fully open position.
- Manually raise the door to the open position
(parallel to the floor), and lift the door arm to the
trolley. The arm should touch the trolley just in
back of the door arm connector hole. Refer to
the fully open trolley/door arm positions in the
illustration. If the arm does not extend far
enough, adjust the limit further. One full turn
equals 2" (5 cm) of trolley travel.
• Secure with a ring fastener.
• Run the opener through a complete travel cycle.
If the door has a slight “backward” slant in full
open position as shown in the illustration,
decrease the UP limit until the door is parallel
to the floor.
NOTE: When setting the up limit on the following
page, the door should not have a “backward” slant
when fully open as illustrated below. A slight
backward slant will cause unnecessary bucking
and/or jerking operation as the door is being opened
or closed from the fully open position.
• Closed door adjustment: decrease DOWN
travel limit
- Turn the DOWN limit adjustment screw
clockwise 4 complete turns.
Figure 5
Inner Trolley
Outer Trolley
Door Arm
Connector Hole
Door Arm
Emergency Release Handle
Closed
Door
Inner Trolley
Outer Trolley
Door Arm
Connector Hole
Correct Angle
Door with
Backward Slant
(Incorrect)
Open Door
26
Download from Www.Somanuals.com. All Manuals Search And Download.
ADJUSTMENT STEP 1
WARNING
Without a properly installed safety reversal system,
persons (particularly small children) could be
SERIOUSLY INJURED or KILLED by a closing garage
door.
• Incorrect adjustment of garage door travel limits will
interfere with proper operation of safety reversal
system.
• If one control (force or travel limits) is adjusted, the
other control may also need adjustment.
Adjust the UP and DOWN Travel
Limits
Limit adjustment settings regulate the points at which
the door will stop when moving up or down.
To operate the opener, press the Door Control push
bar. Run the opener through a complete travel cycle.
• Does the door open and close completely?
• Does the door stay closed and not reverse
unintentionally when fully closed?
• After ANY adjustments are made, the safety reversal
system MUST be tested. Door MUST reverse on
contact with 1-1/2" high (3.8 cm) object (or 2x4 laid
flat) on floor.
If your door passes both of these tests, no limit
adjustments are necessary unless the reversing test
fails (Adjustment Step 3, page 29).
Adjustment procedures are outlined below. Read the
procedures carefully before proceeding to
Adjustment Step 2. Use a screwdriver to make limit
adjustments. Run the opener through a complete
travel cycle after each adjustment.
CAUTION
To prevent damage to vehicles, be sure fully open door
provides adequate clearance.
NOTE: Repeated operation of the opener during
adjustment procedures may cause the motor to
overheat and shut off. Simply wait 15 minutes and
try again.
NOTE: If anything interferes with the door’s upward
travel, it will stop. If anything interferes with the door’s
downward travel (including binding or unbalanced
doors), it will reverse.
+
+
HOW AND WHEN TO ADJUST THE LIMITS
Limit
Left Side Panel
Adjustment
Screws
• If the door does not open completely but opens
at least 5 feet (1.5 m):
Increase up travel. Turn the UP limit adjustment
screw clockwise. One turn equals 2" (5 cm) of
travel.
Adjust UP Travel
• If door does not open at least 5 feet (1.5 m):
+
Adjust the UP (open) force as explained in
Adjustment Step 2.
Adjust DOWN Travel
+
• If the door does not close completely:
Increase down travel. Turn the down limit
adjustment screw counterclockwise. One turn
equals 2" (5 cm) of travel.
• If the door reverses when closing and there is
no visible interference to travel cycle:
If door still won't close completely try lengthening
the door arm (page 25) and decreasing the down
limit.
If the opener lights are flashing, the Safety
Reversing Sensors are either not installed,
misaligned, or obstructed. See Troubleshooting,
page 22.
• If the opener reverses in fully closed position:
Decrease down travel. Turn the down limit
adjustment screw clockwise. One turn equals 2"
(5 cm) of travel.
Test the door for binding: Pull the emergency
release handle. Manually open and close the door.
If the door is binding or unbalanced, call for a
trained door systems technician. If the door is
balanced and not binding, adjust the DOWN
(close) force. See Adjustment Step 2.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNING
Without a properly installed safety reversal system,
persons (particularly small children) could be
SERIOUSLY INJURED or KILLED by a closing garage
door.
• Too much force on garage door will interfere with
proper operation of safety reversal system.
• NEVER increase force beyond minimum amount
required to close garage door.
• NEVER use force adjustments to compensate for a
binding or sticking garage door.
• If one control (force or travel limits) is adjusted, the
other control may also need adjustment.
• After ANY adjustments are made, the safety reversal
system MUST be tested. Door MUST reverse on
contact with 1-1/2" high (3.8 cm) object (or 2x4 laid
flat) on floor.
ADJUSTMENT STEP 2
Adjust the Force
Force adjustment controls are located on the back
panel of the motor unit. Force adjustment settings
regulate the amount of power required to open and
close the door.
If the forces are set too light, door travel may be
interrupted by nuisance reversals in the down
direction and stops in the up direction. Weather
conditions can affect the door movement, so
occasional adjustment may be needed.
The maximum force adjustment range is about
3/4 of a complete turn. Do not force controls
beyond that point. Turn force adjustment controls
with a screwdriver.
NOTE: If anything interferes with the door’s upward
travel, it will stop. If anything interferes with the door’s
downward travel (including binding or unbalanced
doors), it will reverse.
HOW AND WHEN TO ADJUST THE FORCES
Force Adjustment
Controls
1. Test the DOWN (close) force
Back Panel
• Grasp the door bottom when the door is about
halfway through DOWN (close) travel. The door
should reverse. Reversal halfway through down
travel does not guarantee reversal on a 1-1/2"
(3.8 cm) obstruction. See Adjustment Step 3,
page 29. If the door is hard to hold or doesn't
reverse, DECREASE the DOWN (close) force by
turning the control counterclockwise. Make small
adjustments until the door reverses normally.
After each adjustment, run the opener through a
complete cycle.
9
7
1
3
kg
kg
5
• If the door reverses during the down (close)
cycle and the opener lights aren't flashing,
INCREASE DOWN (close) force by turning the
control clockwise. Make small adjustments until
the door completes a close cycle. After each
adjustment, run the opener through a complete
travel cycle. Do not increase the force beyond the
minimum amount required to close the door.
UP
Force
DOWN
Force
9
7
1
3
kg
kg
5
2. Test the UP (open) force
• Grasp the door bottom when the door is about
halfway through UP (open) travel. The door
should stop. If the door is hard to hold or
doesn't stop, DECREASE UP (open) force by
turning the control counterclockwise. Make small
adjustments until the door stops easily and opens
fully. After each adjustment, run the opener
through a complete travel cycle.
• If the door doesn’t open at least 5 feet (1.5 m),
INCREASE UP (open) force by turning the
control clockwise. Make small adjustments until
door opens completely. Readjust the UP limit if
necessary. After each adjustment, run the opener
through a complete travel cycle.
28
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNING
ADJUSTMENT STEP 3
Test the Safety Reversal System
Without a properly installed safety reversal system,
persons (particularly small children) could be
SERIOUSLY INJURED or KILLED by a closing garage
door.
TEST
• With the door fully open, place a 1-1/2" (3.8 cm)
board (or a 2x4 laid flat) on the floor, centered
under the garage door.
• Safety reversal system MUST be tested every month.
• If one control (force or travel limits) is adjusted, the
other control may also need adjustment.
• After ANY adjustments are made, the safety reversal
system MUST be tested. Door MUST reverse on
contact with 1-1/2" high (3.8 cm) object (or 2x4 laid
flat) on the floor.
• Operate the door in the down direction. The door
must reverse on striking the obstruction.
ADJUST
• If the door stops on the obstruction, it is not
traveling far enough in the down direction.
Increase the DOWN limit by turning the DOWN
limit adjustment screw counterclockwise 1/4 turn.
NOTE: On a sectional door, make sure limit
adjustments do not force the door arm beyond a
straight up and down position. See the illustration
on page 25.
• Repeat the test.
• When the door reverses on the 1-1/2" (3.8 cm)
board, remove the obstruction and run the opener
through 3 or 4 complete travel cycles to test
adjustment.
• If the unit continues to fail the Safety Reverse Test,
call for a trained door systems technician.
IMPORTANT SAFETY CHECK:
Test the Safety Reverse System after:
• Each adjustment of door arm length, limits, or
force controls.
1-1/2" (3.8 cm) board
(or a 2x4 laid flat)
• Any repair to or adjustment of the garage door
(including springs and hardware).
• Any repair to or buckling of the garage floor.
• Any repair to or adjustment of the opener.
WARNING
Without a properly installed safety reversing sensor,
persons (particularly small children) could be
SERIOUSLY INJURED or KILLED by a closing garage
door.
ADJUSTMENT STEP 4
®
Test The Protector System
• Press the remote control push button to open the
door.
• Place the opener carton in the path of the door.
• Press the remote control push button to close the
door. The door will not move more than an inch
(2.5 cm), and the opener lights will flash.
The garage door opener will not close from a remote
if the indicator light in either sensor is off (alerting
you to the fact that the sensor is misaligned or
obstructed).
If the opener closes the door when the safety
reversing sensor is obstructed (and the sensors
are no more than 6" (15 cm) above the floor), call
for a trained door systems technician.
Safety Reversing Sensor
Safety Reversing Sensor
29
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION
IMPORTANT SAFETY INSTRUCTIONS
WARNING
To reduce the risk of SEVERE INJURY or DEATH:
1. READ AND FOLLOW ALL WARNINGS AND
INSTRUCTIONS.
9. If one control (force or travel limits) is adjusted, the
other control may also need adjustment.
2. ALWAYS keep remote controls out of reach of children.
NEVER permit children to operate or play with garage
door control push buttons or remote controls.
3. ONLY activate garage door when it can be seen clearly, it
is properly adjusted, and there are no obstructions to
door travel.
4. ALWAYS keep garage door in sight until completely
closed. NO ONE SHOULD CROSS THE PATH OF THE
MOVING DOOR.
10. After ANY adjustments are made, the safety reversal
system MUST be tested.
11. Safety reversal system MUST be tested every month.
Garage door must reverse on contact with 1-1/2" high
(3.8 cm) object (or a 2x4 laid flat) on the floor.
12. ALWAYS KEEP GARAGE DOOR PROPERLY BALANCED
(see page 3). An improperly balanced door may not
reverse when required and could result in SEVERE
INJURY or DEATH.
5. NO ONE SHOULD GO UNDER A STOPPED, PARTIALLY
OPENED DOOR.
6. If possible, use emergency release handle to disengage
trolley ONLY when garage door is CLOSED. Weak or
broken springs or unbalanced door could result in an
open door falling rapidly and/or unexpectedly.
13. All repairs to cables, spring assemblies and other
hardware, all of which are under EXTREME tension,
MUST be made by a trained door systems technician.
14. ALWAYS disconnect electric power to garage door
opener BEFORE making any repairs or removing
covers.
7. NEVER use emergency release handle unless garage
doorway is clear of persons and obstructions.
8. NEVER use handle to pull garage door open or closed. If
rope knot becomes untied, you could fall.
15.
SAVE THESE INSTRUCTIONS.
6. If obstructed while opening, the door will stop.
Using Your Garage Door Opener
7. If fully open, the door will not close when the beam
is broken. The sensor has no effect in the opening
cycle.
Your Security✚® opener and hand-held remote
control have been factory-set to a matching code
which changes with each use, randomly accessing
over 100 billion new codes. Your opener will operate
with up to eight Security✚® remote controls and one
Security✚® Keyless Entry System. If you purchase a
new remote, or if you wish to deactivate any remote,
follow the instructions in the Programming section.
If the sensor is not installed, or is misaligned, the
door won't close from a hand-held remote. However,
you can close the door with the Door Control, the
Outdoor Key Switch, or Keyless Entry, if you activate
them until down travel is complete. If you release
them too soon, the door will reverse.
Activate your opener with any of the following:
• The hand-held Remote Control: Hold the large
push button down until the door starts to move.
• The wall-mounted Door Control: Hold the push
button or bar down until the door starts to move.
• The Keyless Entry (See Accessories): If provided
with your garage door opener, it must be
The opener lights will turn on under the following
conditions: when the opener is initially plugged in;
when power is restored after interruption; when the
opener is activated.
They will turn off automatically after 4-1/2 minutes or
provide constant light when the Light feature on the
Multi-Function Door Control Panel is activated. Bulb
size is A19. Bulb power is 100 watts maximum.
programmed before use. See Programming.
Security✚® light feature: Lights will also turn on
when someone walks through the open garage door.
With a Multi-Function Door Control Panel, this
feature may be turned off as follows: With the opener
lights off, press and hold the light button for 10
seconds, until the light goes on, then off again. To
restore this feature, start with the opener lights on,
then press and hold the light button for 10 seconds
until the light goes off, then on again.
When the opener is activated (with the safety
reversing sensor correctly installed and aligned)
1. If open, the door will close. If closed, it will open.
2. If closing, the door will reverse.
3. If opening, the door will stop.
4. If the door has been stopped in a partially open
position, it will close.
5. If obstructed while closing, the door will reverse. If
the obstruction interrupts the sensor beam, the
opener lights will blink for five seconds.
30
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Wall-Mounted
Door Control
To Open the Door Manually
WARNING
THE MULTI-FUNCTION DOOR
CONTROL
Lighted
Push Button
To prevent possible SERIOUS INJURY or DEATH from a
falling garage door:
Press the lighted push button to
open or close the door. Press
again to reverse the door during
the closing cycle or to stop the
door while it's opening.
Lock
Button
• If possible, use emergency release handle to
disengage trolley ONLY when garage door is CLOSED.
Weak or broken springs or unbalanced door could
result in an open door falling rapidly and/or
unexpectedly.
• NEVER use emergency release handle unless garage
doorway is clear of persons and obstructions.
LOCK
Light
Button
LIGHT
Light feature
Press the Light button to turn the opener light on or
off. It will not control the opener lights when the door
is in motion. If you turn it on and then activate the
opener, the light will remain on for 4-1/2 minutes.
Press again to turn it off sooner. The 4-1/2 minute
interval can be changed to 1-1/2, 2-1/2, or 3-1/2
minutes as follows: Press and hold the Lock button
until the light blinks (about 10 seconds). A single blink
indicates that the timer is reset to 1-1/2 minutes.
Repeat the procedure and the light will blink twice,
resetting the timer to 2-1/2 minutes. Repeat again for
a 3-1/2 minute interval, etc., up to a maximum of four
blinks and 4-1/2 minutes.
• NEVER use handle to pull door open or closed. If rope
knot becomes untied, you could fall.
DISCONNECT THE TROLLEY:
The door should be fully closed
if possible. Pull down on the
emergency release handle (so
that the trolley release arm
snaps into a vertical position)
and lift the door manually.
Trolley
Trolley
Release Arm
(in Manual
Disconnect
Position)
The lockout feature prevents
N
O
T
IC
E
Lock feature
the trolley from reconnecting
automatically, and the door
can be raised and lowered
manually as often as
necessary.
Designed to prevent operation of the door from
hand-held remote controls. However, the door will
open and close from the Door Control, the Outdoor
Keylock and the Keyless Entry Accessories.
Lockout position
(Manual disconnect)
To activate, press and hold the Lock button for 2
seconds. The push button light will flash as long as
the Lock feature is on.
TO RE-CONNECT THE
TROLLEY:
To turn off, press and hold the Lock button again for
2 seconds. The push button light will stop flashing.
The Lock feature will also turn off whenever the
“learn” button on the motor unit panel is activated.
Trolley
Pull the emergency release
handle toward the opener at
an angle so that the trolley
release arm is horizontal. The
trolley will reconnect on the
next UP or DOWN operation,
either manually or by using
the door control or remote.
Trolley
Release
Emergency
Arm
Release
Handle
NOTICE
Additional feature when used with the 3-Button
hand-held remote
(Pull at 45° angle)
To control the opener lights:
To reconnect
In addition to operating the door,
you may program the remote to
operate the lights.
1. With the door closed, press and hold a small
remote button that you want to control the light.
2. Press and hold the Light button on the door
control.
3. While holding the Light button, press and hold the
Lock button on the door control.
4. After the opener lights flash, release all buttons.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
THE REMOTE CONTROL BATTERY
CARE OF YOUR OPENER
LIMIT AND FORCE ADJUSTMENTS:
WARNING
Weather conditions may cause some
minor changes in door operation
requiring some
To prevent possible SERIOUS INJURY or DEATH:
• NEVER allow small children near batteries.
• If battery is swallowed, immediately notify doctor.
+
re-adjustments,
particularly during
the first year of
operation.
9
7
1
3
kg
kg
5
The lithium battery should
produce power for up to
5 years. To replace battery,
use the visor clip or
screwdriver blade to pry open
the case as shown. Insert
battery positive side up (+).
+
LIMIT CONTROLS
FORCE CONTROLS
Pages 27 and 28
refer to the limit
Battery
positive
side up (+)
and force adjustments. Only a screwdriver is
required. Follow the instructions carefully.
Repeat the safety reverse test (Adjustment
Step 3, page 29) after any adjustment of limits or
force.
Dispose of old battery
properly.
MAINTENANCE SCHEDULE
Once a Month
NOTICE: To comply with FCC and or Industry Canada rules (IC), adjustment or
modifications of this receiver and/or transmitter are prohibited, except for changing the
code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to
the following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.
• Manually operate door. If it is unbalanced or
binding, call a trained door systems technician.
• Check to be sure door opens & closes fully. Adjust
limits and/or force if necessary. (See pages 27
and 28)
• Repeat the safety reverse test. Make any
necessary adjustments. (See Adjustment Step 3)
Once a Year
• Oil door rollers, bearings and hinges. The opener
does not require additional lubrication. Do not
grease the door tracks.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
HAVING A PROBLEM?
1. My door will not close and the light bulbs blink
on my motor unit: The safety reversing sensor
must be connected and aligned correctly before the
garage door opener will move in the down direction.
• Verify the safety sensors are properly installed,
aligned and free of any obstructions. Refer to
Installation Step 10: Install The Protector System®.
• Check diagnostic LED for flashes on the motor
unit then refer to the Diagnostic Chart on the
following page.
2. My remotes will not activate the door:
"Learn"
Button
LED or
Diagnostic
LED
• Verify your Premium door control is not blinking. If
it is blinking, deactivate the Lock Mode following
the instructions for Using the Multi-Function Door
Control.
• Reprogram remotes following the programming
instructions. Refer to Programming.
Receiving Eye Safety Reversing
Sensor (Green Indicator Light)
Sending Eye Safety Reversing
Sensor (Amber Indicator Light)
• If remote will still not activate your door, check
diagnostic LED for flashes on motor unit then
refer to Diagnostic Chart on the following page.
3. My door reverses for no apparent reason:
Repeat safety reverse test after adjustments to
force or travel limits. The need for occasional
adjustment for the force and limit settings is normal.
Weather conditions in particular can affect door
travel.
5. My lights will not turn off when door is open:
• The garage door opener is equipped with a
security light feature. This feature activates the
light on when the safety sensor beam has been
obstructed. Refer to Operation section; Using the
Wall Mounted Door Control, Light Feature.
• Manually check door for balance or any binding
problems.
• Refer to Adjustment Step 2, Adjust the Force.
4. My door reverses for no apparent reason after
fully closing and touching the floor: Repeat
safety reverse test after adjustments to force or
travel limits. The need for occasional adjustment for
the force and limit settings is normal. Weather
conditions in particular can affect door travel.
• Refer to Adjustment Step 1, Adjust the UP and
DOWN Travel Limits. Decrease down travel by
turning down limit adjustment screw clockwise.
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Installed
Safety Reversing
Sensor
Diagnostics
Located On
Motor Unit
LED or
Diagnostic
LED
Your garage door opener is programmed with
self-diagnostic capabilities. The “Learn” button/diagnostic
LED will flash a number of times then pause signifying it
has found a potential issue. Consult Diagnostic Chart below.
"Learn"
Button
Diagnostic Chart
Symptom: One or both of the Indicator lights on the safety sensors do
not glow steady.
• Inspect sensor wires for a short (staple in wire), correct wiring polarity
(black/white wires reversed), broken or disconnected wires, replace/attach
as needed.
1 FLASH
Safety sensors wire open
(broken or disconnected).
OR
• Disconnect all wires from back of motor unit.
• Remove sensors from brackets and shorten sensor wires to 1-2 ft
(30-60 cm) from back each of sensor.
2 FLASHES
• Reattach sending eye to motor unit using shortened wires. If sending eye
indicator light glows steadily, attach the receiving eye.
• Align sensors, if the indicator lights glow replace the wires for the sensors.
If the sensor indicator lights do not light, replace the safety sensors.
Safety sensors wire
shorted or black/white
wire reversed.
Symptom: LED is not lit on door control.
• Inspect door control/wires for a short (staple in wire), replace as needed.
• Disconnect wires at door control, touch wires together. If motor unit
activates, replace door control.
3 FLASHES
Door control or
wire shorted.
• If motor unit does not activate, disconnect door control wires from motor
unit. Momentarily short across red and white terminals with jumper wire.
If motor unit activates, replace door control wires.
4 FLASHES
Symptom: Sending indicator light glows steadily, receiving indicator
light is dim or flashing.
• Realign receiving eye sensor, clean lens and secure brackets.
Safety Sensors
slightly misaligned
(dim or flashing LED).
• Verify door track is firmly secured to wall and does not move.
Symptom: Motor has over heated; the motor unit does not operate;
RPM Sensor = Short travel 6-8" (15-20 cm).
• Unplug unit to reset. Try to operate motor unit, check diagnostic code.
• If it is still flashing 5 times and motor unit moves 6-8" (15-20 cm), replace
RPM sensor.
5 FLASHES
Motor overheated or
possible RPM sensor
failure. Unplug to reset.
• If motor unit does not operate, motor unit is overheated. Wait 30 minutes
and retry. If motor unit still will not operate replace logic board.
Symptom: Motor unit does not operate.
• Replace logic board because motor rarely fails.
6 FLASHES
Motor Circuit Failure.
Replace Receiver
Logic Board.
34
Download from Www.Somanuals.com. All Manuals Search And Download.
PROGRAMMING
NOTICE: If this Security✚® garage door opener is operated with a non-rolling code transmitter, the technical
measure in the receiver of the garage door opener, which provides security against code-theft devices, will be
circumvented. The owner of the copyright in the garage door opener does not authorize the purchaser or
supplier of the non-rolling code transmitter to circumvent that technical measure.
Your garage door opener has already been programmed at the factory to operate with your hand-held remote
control. The door will open and close when you press the large push button.
Below are instructions for programming your opener to operate with additional Security✚® remote controls.
To Add or Reprogram a Hand-held Remote Control
USING THE “LEARN” BUTTON
USING THE MULTI-FUNCTION DOOR CONTROL
LOCK
LIGHT
1. Press and hold the button on the
hand-held remote* that you wish
to operate your garage door.
1. Press and release the “learn”
button on the motor unit. The
learn indicator light will glow
steadily for 30 seconds.
2. While holding the remote button,
press and hold the LIGHT button
on the Multi-Function Door
2. Within 30 seconds, press and
hold the button on the hand-held
remote* that you wish to operate
your garage door.
Control.
LOCK
LIGHT
3. Continue holding both buttons
while you press the push bar on
the Multi-Function Door Control
(all three buttons are held).
3. Release the button when the
motor unit lights blink. It has
learned the code. If light bulbs are
not installed, two clicks will be
heard.
LOCK
LIGH
4. Release buttons when the motor
unit lights blink. It has learned
the code. If light bulbs are not
installed, two clicks will be heard.
To Erase All Codes From Motor
Unit Memory
*3-Button Remotes
If provided with your garage door opener, the large
button is factory programmed to operate it. Additional
buttons on any
To deactivate any unwanted remote,
first erase all codes:
Security✚® 3-Button
remote or compact
remote can be
Press and hold the “learn” button on
motor unit until the learn indicator light
goes out (approximately 6 seconds).
All previous codes are now erased. Reprogram each
remote or keyless entry you wish to use.
programmed to operate
other Security✚®
garage door openers.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
To Add, Reprogram or Change a Keyless Entry PIN
NOTE: Your new Keyless Entry must be programmed to operate your garage door opener.
USING THE “LEARN” BUTTON
USING THE MULTI-FUNCTION DOOR CONTROL
LOCK
LIGHT
NOTE: This method requires two people if the Keyless
Entry is already mounted outside the garage.
1. Press and release the “learn”
button on motor unit. The learn
indicator light will glow steadily for
30 seconds.
1. Enter a four digit personal
identification number (PIN) of your
choice on the keypad. Then press
and hold ENTER.
2. Within 30 seconds, enter a four
digit personal identification
number (PIN) of your choice on
the keypad. Then press and hold
the ENTER button.
2. While holding the ENTER button,
press and hold the LIGHT button
on the Multi-Function Door
Control.
K
LOC
LIGHT
3. Release the button when the
motor unit lights blink. It has
learned the code. If light bulbs are
not installed, two clicks will be
heard.
3. Continue holding the ENTER and
LIGHT buttons while you press
the push bar on the Multi-Function
Door Control (all three buttons are
held).
LOCK
LIGH
4. Release buttons when the motor
unit lights blink. It has learned the
code. If light bulbs are not
To change an existing, known PIN
If the existing PIN is known, it may be changed by one
person without using a ladder.
installed, two clicks will be heard.
1. Press the four buttons for the present PIN, then
press and hold the # button.
The opener light will blink twice. Release the #
button.
3. To set the number of hours this temporary PIN will
work, press the number of hours (up to 255), then
2. Press the new 4-digit PIN you have chosen, then
press Enter.
press ✽.
OR
The motor unit lights will blink once when the PIN has
been learned.
3. To set the number of times this temporary PIN will
work, press the number of times (up to 255), then
press #.
Test by pressing the new PIN, then press Enter. The
door should move.
The opener light will blink once when the temporary PIN
has been learned.
To set a temporary PIN
You may authorize access by visitors or service people
with a temporary 4-digit PIN. After a programmed
number of hours or number of accesses, this temporary
PIN expires and will no longer open the door. It can be
used to close the door even after it has expired. To set
a temporary PIN:
Test by pressing the four buttons for the temporary PIN,
then press Enter. The door should move. If the
temporary PIN was set to a certain number of openings,
remember that the test has used up one opening.To
clear the temporary password, repeat steps 1-3, setting
the number of hours or times to 0 in step 3.
1. Press the four buttons for your personal entry PIN
(not the last temporary PIN), then press and hold the
✽ button.
One Button Close: Opener can be closed by pressing
only the ENTER button if the one button close feature
has been activated. This feature has been activated at
the factory. To activate or deactivate this feature press
and hold buttons 1 and 9 for 10 seconds. The keypad
will blink twice when the one button close is active. The
keypad will blink four times when one button close is
deactivated.
The opener light will blink three times. Release the
button.
2. Press the temporary 4-digit PIN you have chosen,
then press Enter.
The opener light will blink four times.
36
Download from Www.Somanuals.com. All Manuals Search And Download.
REPAIR PARTS
Rail Assembly Parts
9
10
1
2
8
7
4
3
KEY PART
NO. NO.
DESCRIPTION
1
2
41A4796
41A4795
Hardware bag
Hardware bag (includes
sprocket coupling)
3
12B569-1 Left rail bracket
4
12B569-2 Right rail bracket
5
6
1C4827-1 Screw drive rail assembly
12B560M Rail support braces (4)
5
6
7
8
9
10
81C168
41C4677
25C20
Rack
Complete trolley assembly
Sprocket coupling
Drive sprocket kit
41A4836
Installation Parts
4
2
1
3
KEY PART
NO. NO.
LOCK
LIGHT
DESCRIPTION
1
2
3
4
5
6
7
8
9
41A5273-14 Multi-function door control
Y
L
N
O
T
N
U
O
M
G
N
I
L
I
E
C
P
U
953D
3-Button remote control
6
10A20
3V 2032 Lithium battery
7
5
29B137
41A2828
41B4494-1
41A4353
41A5047
41A5034
Visor clip
Emergency release rope & handle assy.
2-Conductor bell wire: white & white/red
Header bracket w/clevis pin & fastener
Door bracket w/clevis pin & fastener
Safety sensor kit: receiving and
sending eyes with 3' 2-conductor bell
wire attached
N
O
TIC
E
10
11
10
11
12
13
178B34
12B776
178B35
41A5266-1
Straight door arm section
Hanging bracket
Curved door arm section
Safety sensor bracket
NOT SHOWN
9
8
13
41A4675-7
114A3059
Installation hardware bag (see page 7)
Owner’s manual
12
114A3059SP Owner’s manual - Spanish
37
Download from Www.Somanuals.com. All Manuals Search And Download.
Motor Unit Assembly Parts
(Down)
Contact
1
LIMIT SWITCH ASSY.
Brown
Wire
2
D N
Grey
Wire
U P
Drive
Gear
17
Center Limit
Contact
(Up)
Yellow
Contact
Wire
7
15
14
5
6
3
8b
8
8d
4
8d
18
8a
8c
10
8f
8e
11a
11
11
9
12
13
16
KEY PART
KEY PART
NO.
NO.
DESCRIPTION
NO.
NO.
DESCRIPTION
1
2
3
4
5
6
7
8
31D477
41B4245
30B532
12A373
Drive shaft cover
Line cord
8f
41A5394
41C4672
Assy. bracket motor mount
Screw drive RPM kit
9
Capacitor – 1/2 HP
Capacitor bracket
10
11
11a
12
13
14
15
16
17
18
41A4837-1 Worm gear and retainer
41C5417
41C5416
41AS050
Low voltage wire harness
High voltage wire harness
Receiver logic board assy.
41B3878-1 Terminal block w/screws
41D4671
12D630
Limit switch assembly
Bracket: light socket, limit switch
Motor drive assy complete with:
41A5490-1 Cover
41A5388
41C22-1
175C147
108D78
41A5387
12B654
Drive coupling hub
8a
8b
8c
8d
8e
144B41
144B42
20B19
158A69
41C556
22T Pulley
28T Pulley
Drive belt
Retainer rings
Isolator bracket spacers
Light socket
Light lens
Chassis with rail bracket
Motor support bracket
38
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORIES
953D
3-Button Security✚® Remote
Control:
3-Button Mini-Remote Control with
956D
Security✚®:
Includes visor clip.
With key ring and fastening strip.
945CB
Multi-Function Door Control Panel:
7702CB
7706CB
Outside Quick Release:
Provides a Lock Feature which
prevents operation of garage door
opener from hand-held remotes and
a Light Feature for constant light.
Required for a garage with NO
access door. Enables homeowner to
open garage door manually from
outside by disengaging trolley.
LOCK
LIGHT
935CB
940D
Motion Detecting Control Panel:
8 Foot Rail Extension Kit:
Multi-function door control with motion
sensor that automatically turns opener
lights on for 5 minutes when it detects
a person entering the garage. Sensor
can be easily deactivated when
desired.
To allow an 8 foot door to open fully.
LOCK
LIGHT
41A5281
Extension Brackets:
SECURITY✚® Keyless Entry:
(Optional) For safety sensor
installation onto the wall or floor.
Enables homeowner to operate
garage door opener from outside by
entering a password on a specially
designed keyboard. Also can add a
temporary password for visitors or
service persons. This temporary
password can be limited to a
programmable number of hours or
entries.
To order call: 1-800-528-9131
39
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAMBERLAIN®
SERVICE IS ON CALL
HOW TO ORDER
REPAIR PARTS
Selling prices will be furnished on request or parts will
be shipped at prevailing prices and you will be billed
accordingly.
OUR LARGE SERVICE ORGANIZATION
SPANS AMERICA
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE
THE FOLLOWING INFORMATION:
INSTALLATION AND SERVICE INFORMATION
IS AS NEAR ASYOUR TELEPHONE.
SIMPLY DIAL OUR TOLL FREE NUMBER:
• PART NUMBER
• PART NAME
• MODEL NUMBER
1-800-528-9131
ADDRESS ORDERS TO:
THE CHAMBERLAIN GROUP, INC.
Technical Support Group
6020 S. Country Club Road
Tucson, Arizona 85706
For professional installation, parts and service,
contact your local CHAMBERLAIN dealer. Look for him
in the Yellow Pages, or call our Service number for a
list of dealers in your area.
SERVICE INFORMATION TOLL FREE NUMBER:
1-800-528-9131
CHAMBERLAIN® ONE YEAR LIMITED WARRANTY
6 YEAR MOTOR LIMITED WARRANTY
The Chamberlain Group, Inc. (“Seller”) warrants to the first retail purchaser of this product, for the residence in which this product is
originally installed, that it is free from defect in materials and/or workmanship for a period of one year from the date of purchase [and
that the motor is free from defect in materials and/or workmanship for a period of 6 years from the date of purchase]. The proper
operation of this product is dependent on your compliance with the instructions regarding installation, operation, maintenance and
testing. Failure to comply strictly with those instructions will void this limited warranty in its entirety.
If, during the limited warranty period, this product appears to contain a defect covered by this limited warranty, call 1-800-528-9131, toll
free, before dismantling this product. Then send this product, pre-paid and insured, to our service center for warranty repair. You will
be advised of shipping instructions when you call. Please include a brief description of the problem and a dated proof-of-purchase
receipt with any product returned for warranty repair. Products returned to Seller for warranty repair, which upon receipt by Seller are
confirmed to be defective and covered by this limited warranty, will be repaired or replaced (at Seller’s sole option) at no cost to you
and returned pre-paid. Defective parts will be repaired or replaced with new or factory-rebuilt parts at Seller’s sole option.
ALL IMPLIED WARRANTIES FOR THE PRODUCT, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE ONE YEAR LIMITED
WARRANTY PERIOD SET FORTH ABOVE [EXCEPT THE IMPLIED WARRANTIES WITH RESPECT TO THE MOTOR, WHICH ARE
LIMITED IN DURATIONTOTHE 6YEAR LIMITED WARRANTY PERIOD FORTHE MOTOR], AND NO IMPLIED WARRANTIES WILL
EXIST OR APPLY AFTER SUCH PERIOD. Some States do not allow limitations on how long an implied warranty lasts, so the
above limitation may not apply to you. THIS LIMITED WARRANTY DOES NOT COVER NON-DEFECT DAMAGE, DAMAGE
CAUSED BY IMPROPER INSTALLATION, OPERATION OR CARE (INCLUDING, BUT NOT LIMITED TO ABUSE, MISUSE,
FAILURE TO PROVIDE REASONABLE AND NECESSARY MAINTENANCE, UNAUTHORIZED REPAIRS OR ANY ALTERATIONS
TO THIS PRODUCT), LABOR CHARGES FOR REINSTALLING A REPAIRED OR REPLACED UNIT, REPLACEMENT OF
BATTERIES AND LIGHT BULBS OR UNITS INSTALLED FOR NON-RESIDENTIAL USE.
THIS LIMITED WARRANTY DOES NOT COVER ANY PROBLEMS WITH, OR RELATING TO, THE GARAGE DOOR OR GARAGE
DOOR HARDWARE, INCLUDING BUT NOT LIMITED TO THE DOOR SPRINGS, DOOR ROLLERS, DOOR ALIGNMENT OR
HINGES. THIS LIMITED WARRANTY ALSO DOES NOT COVER ANY PROBLEMS CAUSED BY INTERFERENCE. ANY SERVICE
CALL THAT DETERMINES THE PROBLEM HAS BEEN CAUSED BY ANY OF THESE ITEMS COULD RESULT IN A FEE TO YOU.
UNDER NO CIRCUMSTANCES SHALL SELLER BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES
ARISING IN CONNECTION WITH USE, OR INABILITYTO USE,THIS PRODUCT. IN NO EVENT SHALL SELLER’S LIABILITY FOR
BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE OR STRICT LIABILITY EXCEED THE COST OF THE
PRODUCT COVERED HEREBY. NO PERSON IS AUTHORIZED TO ASSUME FOR US ANY OTHER LIABILITY IN CONNECTION
WITH THE SALE OF THIS PRODUCT.
Some States do not allow the exclusion or limitation of consequential, incidental or special damages, so the above limitation or
exclusion may not apply to you. This limited warranty gives you specific legal rights, and you may also have other rights which vary
from state to state.
©2007, The Chamberlain Group, Inc.
114A3059D
All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
|