		 FlexiDome2X   
					VDN-0498   
					en Installation Manual   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					Table of Contents | en   
					3 
					Table of Contents   
					1 
					Safety   
					5 
					5 
					1.1   
					1.2   
					1.3   
					1.3.1   
					1.4   
					1.5   
					1.6   
					Safety precautions   
					Important safety instructions   
					Connection in outdoor applications   
					Safety precautions   
					FCC information   
					6 
					7 
					7 
					9 
					UL certification   
					11   
					11   
					Bosch notice   
					2 
					Introduction   
					13   
					2.1   
					Features   
					13   
					3 
					Installation   
					15   
					15   
					16   
					17   
					17   
					18   
					19   
					3.1   
					Unpacking   
					3.2   
					Disassembly   
					3.3   
					Mounting the unit   
					Mounting tips   
					Flush mounting   
					Surface mounting   
					3.3.1   
					3.3.2   
					3.3.3   
					4 
					Connection and set-up   
					Power and video connections   
					Setting up the camera   
					Camera positioning   
					Menu navigation   
					21   
					21   
					23   
					23   
					25   
					26   
					26   
					27   
					4.1   
					4.2   
					4.2.1   
					4.2.2   
					4.2.3   
					4.2.4   
					4.2.5   
					Focal length and focus   
					Heater   
					Closing the unit   
					5 
					Configuration   
					Menu access   
					Main menu   
					29   
					29   
					29   
					29   
					5.1   
					5.1.1   
					5.1.2   
					Install menu   
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				4 
					en | Table of Contents   
					FlexiDome2X   
					5.2   
					Pre-defined modes   
					30   
					31   
					31   
					32   
					32   
					33   
					34   
					35   
					37   
					38   
					39   
					41   
					42   
					42   
					43   
					44   
					45   
					45   
					5.3   
					Day/Night switching   
					Camera control communication (Bilinx)   
					Main menu structure   
					Mode submenu   
					5.4   
					5.5   
					5.5.1   
					5.5.2   
					5.5.3   
					5.5.4   
					5.5.5   
					5.5.6   
					5.5.7   
					5.6   
					ALC submenu   
					Shutter/AGC submenu   
					Day/Night submenu   
					Enhance / Dynamic Engine submenu   
					Color submenu   
					VMD submenu   
					Install menu structure   
					Language submenu   
					5.6.1   
					5.6.2   
					5.6.3   
					5.6.4   
					5.6.5   
					5.6.6   
					Connections submenu   
					Test signal submenu   
					Camera ID submenu   
					Privacy masking submenu   
					Defaults submenu   
					6 
					Troubleshooting   
					Resolving problems   
					Customer service   
					47   
					47   
					47   
					6.1   
					6.2   
					7 
					Maintenance   
					Repairs   
					49   
					49   
					49   
					7.1   
					7.1.1   
					Transfer and disposal   
					8 
					Technical Data   
					Specifications   
					Dimensions   
					51   
					51   
					53   
					55   
					8.1   
					8.1.1   
					8.1.2   
					Accessories   
					Glossary   
					57   
					AR18-08-B010 | v1.0 | 2009.03   
					Installation Manual   
					Bosch Security Systems   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					Safety | en   
					5 
					1 
					Safety   
					1.1   
					Safety precautions   
					DANGER!   
					High risk: This symbol indicates an imminently hazardous   
					situation such as "Dangerous Voltage" inside the product.   
					If not avoided, this will result in an electrical shock, serious   
					bodily injury, or death.   
					WARNING!   
					Medium risk: Indicates a potentially hazardous situation.   
					If not avoided, this could result in minor or moderate bodily   
					injury.   
					! 
					! 
					CAUTION!   
					Low risk: Indicates a potentially hazardous situation.   
					If not avoided, this could result in property damage or risk of   
					damage to the unit.   
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				6 
					en | Safety   
					FlexiDome2X   
					1.2   
					Important safety instructions   
					Read, follow, and retain for future reference all of the following   
					safety instructions. Heed all warnings on the unit and in the   
					operating instructions before operating the unit.   
					1. Cleaning - Generally, using a dry cloth for cleaning is   
					sufficient but a moist, fluff-free cloth or leather shammy   
					may also be used. Do not use liquid cleaners or aerosol   
					cleaners.   
					2. Heat Sources - Do not install the unit near any heat   
					sources such as radiators, heaters, stoves, or other   
					equipment (including amplifiers) that produce heat.   
					3. Water - Never spill liquid of any kind on the unit.   
					4. Lightning - Take precautions to protect the unit from   
					power and lightning surges.   
					5. Controls adjustment - Adjust only those controls specified   
					in the operating instructions. Improper adjustment of   
					other controls may cause damage to the unit.   
					6. Power sources - Operate the unit only from the type of   
					power source indicated on the label.   
					7. Servicing - Unless qualified, do not attempt to service this   
					unit yourself. Refer all servicing to qualified service   
					personnel.   
					8. Replacement parts - Use only replacement parts specified   
					by the manufacturer.   
					9. Installation - Install in accordance with the manufacturer's   
					instructions and in accordance with applicable local codes.   
					10. Attachments, changes or modifications - Only use   
					attachments/accessories specified by the manufacturer.   
					Any change or modification of the equipment, not   
					expressly approved by Bosch, could void the warranty or,   
					in the case of an authorization agreement, authority to   
					operate the equipment.   
					AR18-08-B010 | v1.0 | 2009.03   
					Installation Manual   
					Bosch Security Systems   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					Safety | en   
					7 
					1.3   
					Connection in outdoor applications   
					1.3.1   
					Safety precautions   
					Coax grounding: If an outside cable system is connected to the   
					unit, ensure that the system is grounded.   
					U.S.A. models only: Section 810 of the National Electrical Code,   
					ANSI/NFPA No.70, provides information regarding proper   
					grounding of the mount and supporting structure, grounding of   
					the coax to a discharge unit, size of grounding conductors,   
					location of discharge unit, connection to ground electrodes,   
					and requirements for the grounding electrode.   
					Power lines: An outdoor system should not be located in the   
					vicinity of overhead power lines, electrical lights, or power   
					circuits, or where it may contact such power lines or circuits.   
					When installing an outdoor system, extreme care should be   
					taken to keep from touching power lines or circuits, as this   
					contact may be fatal. U.S.A. models only - refer to the National   
					Electrical Code Article 820 regarding installation of CATV   
					systems.   
					24 VAC power source: This unit is intended to operate with a   
					limited power source, this power source must comply with   
					EN60950. The unit is intended to operate at 24 VAC. User   
					supplied wiring, from 24 VAC supply to unit, must be in   
					compliance with electrical codes (Class 2 power levels). Do not   
					ground the 24 VAC supply at the terminals or at the unit's   
					power supply terminals.   
					Connection: The unit has connection terminals on flying leads.   
					In wet or outdoor installations make use of the VDA-455SMB   
					accessory or use a field wiring box with Nema 3 or IP55   
					protection level or better. Make the connections inside the   
					water tight compartment. After connections are made ensure   
					that the watertight compartment is tightly closed and cables   
					and conduits are properly sealed to prevent ingress of water.   
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				8 
					en | Safety   
					FlexiDome2X   
					CAUTION!   
					The Low Voltage power supply unit must comply with EN/UL   
					60950. The power supply must be a SELV-LPS unit or a SELV -   
					Class 2 unit (Safety Extra Low Voltage - Limited Power Source).   
					! 
					Disposal - Your Bosch product was developed and   
					manufactured with high-quality material and components that   
					can be recycled and reused. This symbol means that   
					electronic and electrical appliances, which have reached the   
					end of their working life, must be collected and disposed of   
					separately from household waste material. Separate collecting   
					systems are usually in place for disused electronic and   
					electrical products. Please dispose of these units at an   
					environmentally compatible recycling facility, per European   
					Directive 2002/96/EC   
					AR18-08-B010 | v1.0 | 2009.03   
					Installation Manual   
					Bosch Security Systems   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					Safety | en   
					9 
					1.4   
					FCC information   
					FCC & ICES Information   
					(U.S.A. and Canadian Models Only)   
					This equipment has been tested and found to comply with the   
					limits for a Class B digital device, pursuant to part 15 of the   
					FCC Rules. These limits are designed to provide reasonable   
					protection against harmful interference in a residential   
					installation. This equipment generates, uses, and can radiate   
					radio frequency energy and, if not installed and used in   
					accordance with the instructions, may cause harmful   
					interference to radio communications. However, there is no   
					guarantee that interference will not occur in a particular   
					installation. If this equipment does cause harmful interference   
					to radio or television reception, which can be determined by   
					turning the equipment off and on, the user is encouraged to try   
					to correct the interference by one or more of the following   
					measures:   
					– 
					– 
					reorient or relocate the receiving antenna;   
					increase the separation between the equipment and   
					receiver;   
					– 
					– 
					connect the equipment into an outlet on a circuit different   
					from that to which the receiver is connected;   
					consult the dealer or an experienced radio/TV technician   
					for help.   
					Intentional or unintentional modifications, not expressly   
					approved by the party responsible for compliance, shall not be   
					made. Any such modifications could void the user's authority to   
					operate the equipment. If necessary, the user should consult   
					the dealer or an experienced radio/television technician for   
					corrective action.   
					The user may find the following booklet, prepared by the   
					Federal Communications Commission, helpful: How to Identify   
					and Resolve Radio-TV Interference Problems. This booklet is   
					available from the U.S. Government Printing Office,   
					Washington, DC 20402, Stock No. 004-000-00345-4.   
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				10 en | Safety   
					FlexiDome2X   
					Informations FCC et ICES   
					(modèles utilisés aux États-Unis et au Canada uniquement)   
					Suite à différents tests, cet appareil s'est révélé conforme aux   
					exigences imposées aux appareils numériques de classe B, en   
					vertu de la section 15 du règlement de la Commission fédérale   
					des communications des États-Unis (FCC), et en vertu de la   
					norme ICES-003 d'Industrie Canada. Ces exigences visent à   
					fournir une protection raisonnable contre les interférences   
					nuisibles lorsque l'appareil est utilisé dans le cadre d'une   
					installation résidentielle. Cet appareil génère, utilise et émet   
					de l'énergie de radiofréquences et peut, en cas d'installation ou   
					d'utilisation non conforme aux instructions, engendrer des   
					interférences nuisibles au niveau des radiocommunications.   
					Toutefois, rien ne garantit l'absence d'interférences dans une   
					installation particulière. Il est possible de déterminer la   
					production d'interférences en mettant l'appareil   
					successivement hors et sous tension, tout en contrôlant la   
					réception radio ou télévision. L'utilisateur peut parvenir à   
					éliminer les interférences éventuelles en prenant une ou   
					plusieurs des mesures suivantes:   
					– 
					Modifier l'orientation ou l'emplacement de l'antenne   
					réceptrice;   
					– 
					– 
					Éloigner l'appareil du récepteur;   
					Brancher l'appareil sur une prise située sur un circuit   
					différent de celui du récepteur;   
					– 
					Consulter le revendeur ou un technicien qualifié en radio/   
					télévision pour obtenir de l'aide.   
					Toute modification apportée au produit, non expressément   
					approuvée par la partie responsable de l'appareil, est   
					strictement interdite. Une telle modification est susceptible   
					d'entraîner la révocation du droit d'utilisation de l'appareil.   
					La brochure suivante, publiée par la Commission fédérale des   
					communications (FCC), peut s'avérer utile : How to Identify and   
					Resolve Radio-TV Interference Problems (Comment identifier et   
					résoudre les problèmes d’interférences de radio et de télévision).   
					Cette brochure est disponible auprès du U.S. Government   
					AR18-08-B010 | v1.0 | 2009.03   
					Installation Manual   
					Bosch Security Systems   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					Safety | en 11   
					Printing Office, Washington, DC 20402, États-Unis, sous la   
					référence n° 004-000-00345-4.   
					1.5   
					UL certification   
					Disclaimer   
					Underwriter Laboratories Inc. ("UL") has not tested the   
					performance or reliability of the security or signaling aspects of   
					this product. UL has only tested fire, shock and/or casualty   
					hazards as outlined in UL's Standard(s) for Safety for Closed   
					Circuit Television Equipment, UL 2044. UL Certification does not   
					cover the performance or reliability of the security or signaling   
					aspects of this product.   
					UL MAKES NO REPRESENTATIONS, WARRANTIES, OR   
					CERTIFICATIONS WHATSOEVER REGARDING THE   
					PERFORMANCE OR RELIABILITY OF ANY SECURITY OR   
					SIGNALING RELATED FUNCTIONS OF THIS PRODUCT.   
					Disclaimer   
					Underwriter Laboratories Inc. ("UL") has not tested the   
					performance or reliability of the security or signaling aspects of   
					this product. UL has only tested fire, shock and/or casualty   
					hazards as outlined in UL's Standard(s) for Safety for Information   
					Technology Equipment, UL 60950-1. UL Certification does not   
					cover the performance or reliability of the security or signaling   
					aspects of this product.   
					UL MAKES NO REPRESENTATIONS, WARRANTIES, OR   
					CERTIFICATIONS WHATSOEVER REGARDING THE   
					PERFORMANCE OR RELIABILITY OF ANY SECURITY OR   
					SIGNALING-RELATED FUNCTIONS OF THIS PRODUCT.   
					1.6   
					Bosch notice   
					More information   
					For more information please contact the nearest Bosch Security   
					Systems location or visit www.boschsecurity.com   
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					Introduction | en 13   
					2 
					Introduction   
					2.1   
					Features   
					The FlexiDome2X camera is a small, discreet, high-performance   
					surveillance dome containing a high-performance 1/3-inch CCD   
					sensor camera with integral varifocal lens. This surveillence   
					dome can be mounted to an electrical box, to a wall, to a ceiling   
					or in a corner. The sturdy construction and the high impact-   
					resistant polycarbon dome protect the camera module from   
					damage. The camera incorporates advanced (20-bit) digital   
					signal processing and a wide dynamic range CCD sensor for   
					outstanding picture performance.   
					The FlexiDome2X camera is easy to install and ready to use, and   
					offers the best solution for demanding scene conditions.   
					Features include:   
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					– 
					1/3-inch CCD sensor with wide dynamic range (WDR)   
					True Day/Night performance with switchable IR filter   
					540 TVL resolution   
					Indoor and outdoor use   
					IP66 and NEMA 4X compliant   
					High-impact, vandal resistant (exceeds IK10, >50J)   
					Dynamic engine including Smart BLC   
					Adaptive dynamic noise reduction   
					Privacy zones   
					Autoblack   
					Bilinx (bi-directional coaxial communication)   
					Flush, surface, wall-pendant, pipe-pendant or corner   
					mount   
					– 
					Wide operating temperature range   
					(-50 to +55 °C / -58 to +131 °F)   
					Six pre-programmed operation modes   
					Adaptive dynamic noise reduction   
					Multiple language on-screen display   
					Built-in test pattern generator   
					– 
					– 
					– 
					– 
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					Installation | en 15   
					3 
					Installation   
					3.1   
					Unpacking   
					Unpack carefully and handle the equipment with care.   
					The packaging contains:   
					– 
					– 
					– 
					– 
					Integrated FlexiDome camera unit   
					Important safety instructions   
					Quick install instructions   
					CD ROM   
					– 
					– 
					Installation Instructions   
					Adobe Acrobat Reader   
					– 
					Plastic bag with mounting hardware (three SX8 4.5-6 mm   
					mounting plugs and three matching mounting screws), and   
					special screwdriver bit for tamper-resistant screws   
					Plastic bag with two black rubber grommets for surface   
					mount box   
					– 
					– 
					Lens adjustment cap   
					If equipment has been damaged during shipment, repack it in   
					the original packaging and notify the shipping agent or supplier.   
					WARNING!   
					Installation should only be performed by qualified service   
					personnel in accordance with the National Electrical Code or   
					applicable local codes.   
					! 
					! 
					CAUTION!   
					The camera module is a sensitive device and must be handled   
					carefully.   
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				16 en | Installation   
					FlexiDome2X   
					3.2   
					Disassembly   
					The flush-mount version consists of the following parts:   
					Camera module and mounting base   
					Inner liner (with sealing ring)   
					Trim ring   
					Dome   
					Figure 3.1 Flush-mount   
					The surface-mount version consists of the following parts:   
					Surface mounting box   
					Camera module and mounting base   
					Inner liner (with sealing ring)   
					Trim ring   
					Dome   
					Figure 3.2 Surface-mount   
					AR18-08-B010 | v1.0 | 2009.03   
					Installation Manual   
					Bosch Security Systems   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					Installation | en 17   
					To disassemble the unit proceed as follows:   
					1. Use the special screwdriver bit to loosen the three tamper-   
					resistant screws in the trim ring (the screws remain in   
					place).   
					2. Remove the trim ring and dome by pulling them from the   
					base.   
					3. Remove the inner liner (with sealing ring) by pulling it off   
					of the base.   
					4. Remove the pink protective foam.   
					3.3   
					Mounting the unit   
					There are several ways to mount the unit. The method of   
					mounting depends on the type of surface and whether other   
					mounting hardware, such as an electrical box, a surface box or   
					other accessories are used.   
					Note:   
					If the unit is to be surface mounted, then use the Surface Mount   
					Box (SMB). The SMB is sold as a separate item (VDA-455SMB)   
					or is included with the FlexiDome2X with the surface mount   
					option. Other mounting accessories are also sold separately.   
					3.3.1   
					Mounting tips   
					– 
					Use the mounting hole template to assist in marking the   
					correct position for the camera to be mounted.   
					Refer to the dimensions on the mounting hole template to   
					find the exact position of the screw holes and the entry   
					hole for the cables.   
					– 
					– 
					Partially screw in two screws for the keyholes and use   
					them to temporarily hang the camera while the   
					connections are made.   
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				18 en | Installation   
					FlexiDome2X   
					3.3.2   
					Flush mounting   
					Figure 3.3 Flush mounting - hollow surface   
					1.   
					2.   
					3.   
					4.   
					Solid surface (pre-drill three 8mm holes and fit supplied plugs)   
					Three screws (supplied with camera)   
					Integrated camera unit and base   
					Cables   
					Figure 3.4 Flush mounting - electrical box (4S)   
					1.   
					2.   
					3.   
					Two screws (not supplied)   
					Integrated camera unit and base   
					4S electrical box   
					AR18-08-B010 | v1.0 | 2009.03   
					Installation Manual   
					Bosch Security Systems   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					Installation | en 19   
					3.3.3   
					Surface mounting   
					When using the surface mounting box:   
					– 
					With a side connection, remove the cap covering the side   
					entrance.   
					With a rear connection, leave the cap in place.   
					Attach the conduit to the mounting box.   
					Release the two clips at the bottom of the watertight   
					connection compartment to remove it from the mounting   
					box.   
					– 
					– 
					– 
					– 
					– 
					– 
					Open the cover of the watertight compartment in the   
					mounting box by releasing the five clips.   
					Run the power and video cables through separate rubber   
					grommets into the watertight compartment.   
					Run the cable from the camera into the watertight   
					compartment through the supplied grommet.   
					Make the connection inside the watertight compartment   
					and clip on the cover to seal it.   
					Figure 3.5 Surface mounting box VDA-455SMB   
					Note:   
					To ensure a watertight cable entry, use round cables of   
					between 5 and 6 mm (0.2 - 0.24 inches) for power and video   
					connection.   
					Note:   
					Use some silicon spray on the cable to help slide the grommets   
					onto it.   
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				20 en | Installation   
					FlexiDome2X   
					Figure 3.6 Surface mounting - side connection   
					1.   
					2.   
					3.   
					4.   
					5.   
					6.   
					7.   
					Solid surface (pre-drill three 8mm holes and fit supplied plugs)   
					Three screws (supplied with camera)   
					Three screws (M5, supplied)   
					Integrated camera unit and base   
					Surface mounting box (VDA-455SMB)   
					Cables   
					Conduit   
					Figure 3.7 Surface mounting - rear connection   
					1.   
					2.   
					3.   
					4.   
					5 
					6.   
					7.   
					8.   
					Solid surface (three pre-drilled 8mm holes and fit supplied plugs)   
					Three screws (supplied with camera)   
					Three screws (M5, supplied)   
					Integrated camera unit and base   
					Surface mounting box (VDA-455SMB)   
					Cap (remove for side-entry cables)   
					Conduit   
					Cables   
					AR18-08-B010 | v1.0 | 2009.03   
					Installation Manual   
					Bosch Security Systems   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					Connection and set-up | en 21   
					4 
					Connection and set-up   
					4.1   
					Power and video connections   
					The wiring harness has a BNC connector to accept the video   
					coax cable (with male BNC connector) and two stripped low   
					voltage power wires for connection to a power connector. A   
					UTP adapter (VDA-455UTP) is available as an optional accessory   
					to allow a UTP video cable to be connected to the BNC   
					connector.   
					WARNING!   
					Before proceeding, disconnect the power from the power   
					supply cable. Ensure that the voltage of the unit matches the   
					voltage and type of the power supply being used.   
					! 
					The easiest way to connect the cables is as follows:   
					1. Bring the building connections through the surface cable   
					hole so that they hang clear.   
					2. Partially insert two screws into the pre-drilled holes (or   
					adapter plate).   
					3. Using one of the keyholes, hang the mounting base of the   
					camera module on one screw temporarily; tilt the base   
					slightly to gain access to the cable connections.   
					4. Connect the BNC connector of the camera module to the   
					video coax cable.   
					5. Connect the stripped power wires (red +, brown –) to the   
					power supply connector.   
					Note   
					For a DC supply the polarity is important. Incorrect polarity   
					does not damage the camera but it will not switch on.   
					For an AC supply maintain a consistent wiring polarity in   
					multiple camera systems to help avoid potential camera video   
					rolling.   
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				22 en | Connection and set-up   
					FlexiDome2X   
					6. In damp environments ensure that the connections are   
					sealed. (The surface mounting box and the other mounting   
					accessories have a sealed compartment for this purpose.)   
					7. Push the connections back through the surface cable hole.   
					8. Secure the mounting base of the camera module to the   
					surface with three screws.   
					AR18-08-B010 | v1.0 | 2009.03   
					Installation Manual   
					Bosch Security Systems   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					Connection and set-up | en 23   
					4.2   
					Setting up the camera   
					4.2.1   
					Camera positioning   
					CAUTION!   
					The Heater will be hot when in operation - Do not touch.   
					Always switch the heater off when working on the camera, refer   
					to Section 4.2.4 Heater, Page 26 and Section 5.6.2 Connections   
					submenu, Page 42.   
					! 
					To assist in setting up the camera, connect a monitor to the   
					miniature 2.5 mm jack socket (2). This socket provides a   
					composite video signal (with sync). An optional cable (code   
					number S1460) is available for making this connection. When   
					the S1460 cable is attached, there is no video available on the   
					BNC connector to avoid interference.   
					A 
					C 
					B 
					Figure 4.1 Camera parts   
					1.   
					2.   
					3.   
					Heater   
					Monitor jack socket   
					Thumbwheels   
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				24 en | Connection and set-up   
					FlexiDome2X   
					4.   
					5.   
					6.   
					A.   
					B.   
					C.   
					Navigation buttons (5)   
					Focal length   
					Focus   
					Pan-axis rotation   
					Tilt-axis rotation   
					Twist-axis rotation   
					The physical default position of the camera is that the top of   
					the image corresponds to the indication TOP.   
					CAUTION!   
					CCD image sensors are highly sensitive and require special care   
					for proper performance and extended lifetime. Do not expose   
					them to direct sunlight or bright spotlights in operating and   
					non-operating conditions. Avoid bright lights in the field of view   
					of the camera.   
					! 
					The camera module position can be adjusted along three axes.   
					When adjusting the camera position, ensure that the picture   
					display on the monitor is level. Set the camera to the desired   
					position by performing the following steps:   
					– 
					For horizontal adjustment along the pan axis (A), rotate the   
					camera module in the base. Do not rotate more than 360°.   
					To obtain a horizontal horizon (for tilted ceilings or   
					sidewall mounting), rotate the base of the lens along the   
					twist axis (C) to align the picture shown on the monitor.   
					Do not rotate more than 340°.   
					– 
					– 
					For vertical adjustment along the tilt axis (B), loosen   
					thumbwheels, position camera, then gently tighten   
					thumbwheels to secure camera. Do not rotate more than   
					90°.   
					AR18-08-B010 | v1.0 | 2009.03   
					Installation Manual   
					Bosch Security Systems   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					Connection and set-up | en 25   
					4.2.2   
					Menu navigation   
					Five keys, located on the side panel, are used for navigating   
					through the menu system.   
					Up key   
					Menu/Select key (center)   
					Right key   
					Down key   
					Left key   
					Figure 4.2 Navigation   
					– 
					Press the menu/select (center) key to access the menus or   
					to move to the next or previous menu.   
					– 
					Press the menu/select key for approximately 2 seconds to   
					open the Install menu.   
					– 
					– 
					Use the up or down keys to scroll through a menu.   
					Use the left or right keys to move through options or to set   
					parameters.   
					– 
					– 
					When in a menu, quickly double-press the menu/select key   
					to restore the selected item to its factory default.   
					To close all menus at once from any menu, select the Exit   
					item and hold down the menu/select key until the menu   
					display disappears.   
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				26 en | Connection and set-up   
					FlexiDome2X   
					4.2.3   
					Focal length and focus   
					Before adjusting the focal length or focus, place the lens   
					adjustment cap on the lens to ensure that the image sharpness   
					is the same as when the dome is in place.   
					1. Connect a monitor or other display device to either the   
					camera’s BNC connector or to the optional cable (S1460)   
					on the monitor jack. (If S1460 is connected, there is no   
					signal on the BNC connector.)   
					2. Press and hold the menu/select (center) button until the   
					Install menu appears.   
					– 
					The Set focus item is highlighted. Do not change this   
					selection as the camera is now in a special mode for   
					adjusting focus.   
					3. To set the field of view of the varifocal lens, loosen the   
					focal length screw and turn the mechanism until the   
					required view is displayed on the monitor. (Image goes out   
					of focus.)   
					4. Focus the image on the monitor by loosening the focus   
					screw and turning the mechanism until the image is in   
					focus.   
					5. Re-adjust the focal length if necessary.   
					6. Repeat these two adjustments until the desired view is in   
					focus.   
					7. Tighten both screws.   
					8. Use the navigation buttons to move to Exit and press the   
					center button until the menu disappears.   
					9. Remove the lens adjustment cap from the lens and   
					disconnect the monitor.   
					4.2.4   
					Heater   
					When using the camera at low temperatures, set the heater   
					setting to Auto in the Install menu. The heater turns on at   
					ambient temperatures below 0°C (+32°F).   
					AR18-08-B010 | v1.0 | 2009.03   
					Installation Manual   
					Bosch Security Systems   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					Connection and set-up | en 27   
					4.2.5   
					Closing the unit   
					When the camera position is set and all adjustments have been   
					made, close the unit.   
					1. Place the inner liner (with attached sealing ring) in   
					position, aligning its fin with the bracket on the base.   
					2. Place the dome onto the base and rotate until it clips into   
					place. (If necessary clean its surface with a soft cloth.)   
					3. Place the trim ring over the dome.   
					4. Align the tamper-resistant screws in the trim ring with the   
					threaded ends in the mounting base.   
					5. Use the special screwdriver bit supplied to tighten the   
					three tamper-resistant screws.   
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					Configuration | en 29   
					5 
					Configuration   
					The camera normally provides an optimal picture without the   
					need for further adjustments. There are six pre-defined modes   
					with settings to make configuration easier. Advanced set-up   
					options are available in a menu system for getting the best   
					results under special circumstances.   
					The camera implements your changes immediately so that   
					before and after settings are easily compared.   
					5.1   
					Menu access   
					Use the five navigation buttons on the camera for selecting and   
					navigating through the various menus. There are two upper   
					level menus: a Main menu and an Install menu. The menus have   
					functions that can be selected directly or submenus for more   
					detailed set-up. Use the up/down, right/left buttons for   
					navigation.   
					Up button   
					Menu/Select button (center)   
					Right button   
					Down button   
					Left button   
					5.1.1   
					5.1.2   
					Main menu   
					To access the Main menu, press the menu/select button   
					(center) for less than 1 second. The Main menu appears on the   
					monitor. The Main menu allows you to select and set-up the   
					picture enhancement functions. If you are not happy with your   
					changes, you can always recall the default values for the mode.   
					Install menu   
					The camera also has an Install menu in which the installation   
					settings can be set. To access the Install menu, press the   
					menu/select button (center) for longer than 1 second.   
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				30 en | Configuration   
					FlexiDome2X   
					5.2   
					Pre-defined modes   
					There are six pre-defined modes with settings to make   
					configuration easier. You can select one of the six pre-defined   
					modes in the Install/Mode submenu. The modes are defined as   
					follows:   
					1. 24-hour   
					Default installation mode to provide stable pictures over a   
					24-hour period. These settings are optimized for out-of-   
					the-box installation.   
					2. Traffic   
					Capture high-speed objects using default shutter in   
					variable lighting conditions.   
					3. Low light   
					Provide extra enhancement, such as AGC and SensUp to   
					make usable pictures in low-light conditions.   
					4. Smart BLC   
					Settings optimized to capture details in high contrast and   
					extremely bright-dark conditions.   
					5. Low noise   
					Enhancements are set to reduce picture noise. Useful for   
					conditional refresh DVR and IP storage systems because   
					reducing noise reduces the amount of storage required.   
					6. Analog systems   
					Use this mode if the camera is connected to a purely   
					analog system (e.g. matrix switcher with VCR) or to a CRT   
					monitor. Useful mode for evaluating/demonstrating the   
					camera when it is directly connected to a CRT monitor.   
					AR18-08-B010 | v1.0 | 2009.03   
					Installation Manual   
					Bosch Security Systems   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					Configuration | en 31   
					5.3   
					Day/Night switching   
					The camera is equipped with a motorized IR filter. The   
					mechanical IR filter can be removed in low-light or IR   
					illuminated applications by software configuration settings.   
					If Auto switching mode is selected, the camera automatically   
					switches the filter depending on the observed light level. The   
					switching level is programmable. In Auto switching mode the   
					camera prioritizes motion (the camera gives sharp images   
					without motion blur as long as the light level permits) or color   
					(the camera gives color pictures as long as the light level   
					permits). The camera recognizes IR illuminated scenes to   
					prevent unwanted switching to color mode.   
					There are four different methods of controlling the IR filter:   
					– 
					– 
					– 
					– 
					via an alarm input,   
					via Bilinx communication,   
					automatically, based on the observed light levels, or   
					as part of the programmable mode profile.   
					5.4   
					Camera control communication (Bilinx)   
					This camera is equipped with a coaxial communications   
					transceiver (also refered to as Bilinx). In combination with VP-   
					CFGSFT, the camera setting can be changed from any point   
					along the coaxial cable. All menus can be accessed remotely   
					giving full control of the camera. With this method of   
					communication it is also possible to disable the local keys on   
					the camera.   
					To avoid loss of communication on an installed camera, the   
					Communication On/Off selection is not available while using   
					remote control. This function can only be accessed with the   
					camera buttons. Bilinx communications can only be disabled   
					using the buttons on the camera.   
					Disabled camera buttons   
					When the Bilinx communications link is active, the buttons on   
					the camera are disabled.   
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				32 en | Configuration   
					FlexiDome2X   
					5.5   
					Main menu structure   
					Item   
					Selection   
					Submenu   
					Submenu   
					Submenu   
					Submenu   
					Submenu   
					Description   
					Sets up operating modes 1 to 6   
					Video level control   
					Mode   
					ALC   
					Shutter and automatic gain control   
					Shutter/AGC   
					Day/Night   
					Day/Night for color/mono operation   
					Picture enhancement and performance   
					Enhance /   
					Dynamic   
					Engine   
					Submenu   
					Submenu   
					White balance and color rendition   
					Video motion detection   
					Color   
					VMD   
					5.5.1   
					Mode submenu   
					Item   
					Selection   
					Description   
					1 to 6   
					Selects operating mode.   
					Mode name (11 characters maximum)   
					Mode   
					Alphanumeric   
					Mode ID   
					Available   
					mode   
					Copies current mode settings to the mode   
					number selected.   
					Copy active   
					mode   
					numbers   
					Submenu   
					Restores camera to the factory default   
					settings.   
					Default mode   
					EXIT   
					Returns to main menu.   
					AR18-08-B010 | v1.0 | 2009.03   
					Installation Manual   
					Bosch Security Systems   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					Configuration | en 33   
					5.5.2   
					ALC submenu   
					Item   
					Selection   
					Description   
					-15 to +15   
					Selects the range within which the ALC will   
					operate. A positive value is more useful for   
					low-light conditions; a negative value is more   
					useful for very bright conditions.   
					ALC level   
					Some ALC adjustment may improve scene   
					content when Smart/BLC is enabled.   
					-15 to +15   
					Adjusts the balance between peak and   
					average video control. A negative value gives   
					more priority to average light levels; a positive   
					value gives more priority to peak light levels.   
					Video iris lens: choose an average level for   
					best results (peak settings may cause   
					oscillations).   
					Peak/average   
					Slow,medium,   
					fast   
					Adjusts the speed of the video level control   
					loop. For most scenes it should remain at the   
					default value.   
					ALC speed   
					On, Off   
					On - The camera output is optimized for   
					connection to a DVR or IP encoder to   
					compensate for compression methods.   
					DVR/IP   
					Encoder   
					Off - The camera output is optimized for   
					connection to an analog system (matrix   
					switcher or monitor.   
					Returns to main menu.   
					EXIT   
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				34 en | Configuration   
					FlexiDome2X   
					5.5.3   
					Shutter/AGC submenu   
					Item   
					Selection   
					Description   
					AES, FL, Fixed   
					AES (auto-shutter) - the camera automatically   
					sets the optimum shutter speed.   
					Shutter   
					FL - flickerless mode avoids interference from   
					light sources.   
					FIXED - allows a user defined shutter speed.   
					1/50 (PAL),   
					1/60 (NTSC)   
					1/100, 1/120,   
					1/250,   
					In AES mode, the camera tries to maintain the   
					selected shutter speed as long as the light   
					level of the scene is high enough.   
					Default (AES)   
					shutter   
					or   
					Fixed shutter   
					In Fixed mode, selects shutter speed.   
					1/500,   
					1/1000,   
					1/2000,   
					1/5000,   
					1/10K   
					Displays the actual shutter value from the   
					camera to help compare lighting levels and   
					optimum shutter speed during set-up.   
					Actual shutter   
					Gain control   
					On, Fixed   
					0 to 30 dB   
					On - the camera automatically sets the gain to   
					the lowest possible value needed to maintain   
					a good picture.   
					Fixed - sets Fixed AGC value.   
					Selects the maximum value the gain can have   
					during AGC operation.   
					Maximum AGC   
					or   
					Fixed AGC   
					Selects the gain setting for Fixed gain   
					operation (0 is no gain).   
					Displays the actual AGC value from the   
					camera to help compare gain level with   
					lighting levels and picture performance.   
					Actual AGC   
					AR18-08-B010 | v1.0 | 2009.03   
					Installation Manual   
					Bosch Security Systems   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					Configuration | en 35   
					Item   
					Selection   
					Description   
					Off, 2x, 3x, …,   
					10x   
					Selects the factor by which the sensitivity of   
					the camera is increased. It is dynamic and so   
					is only active when light levels are low.   
					When active, some noise or spots may appear   
					in the picture. This is normal camera   
					behavior. It may also cause motion blur on   
					moving objects.   
					SensUp   
					Dynamic   
					Returns to main menu.   
					EXIT   
					5.5.4   
					Day/Night submenu   
					Item   
					Selection   
					Description   
					Auto, Color,   
					Auto - the camera switches the IR cut-off filter   
					on and off depending on the scene   
					illumination level.   
					Day/Night   
					Monochrome   
					Monochrome - the IR cut-off filter is removed,   
					giving full IR sensitivity.   
					Color - the camera always produces a color   
					signal regardless of light levels.   
					-15 to +15   
					Sets the video level in Auto mode at which   
					the camera switches to monochrome   
					operation.   
					Switch level   
					A low (negative) value means that the camera   
					switches to monochrome at a lower light   
					level. A high (positive) value means that the   
					camera switches to monochrome at a higher   
					light level.   
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				36 en | Configuration   
					FlexiDome2X   
					Item   
					Selection   
					Description   
					Motion, Color   
					Priority   
					In AUTO mode:   
					Color - the camera gives a color image as long   
					as the light level permits.   
					Motion - the camera avoids motion blur as   
					long as the light level permits (it switches to   
					monochrome earlier than it would with Color   
					priority).   
					Enhanced,   
					Normal   
					IR contrast   
					Enhanced - the camera optimizes contrast in   
					applications with high IR illumination levels.   
					Select this mode for IR (730 to 940 nm) light   
					sources and for scenes with grass and green   
					foliage.   
					Normal - the camera optimizes contrast in   
					mono applications with visible light   
					illumination.   
					On, Off   
					Color burst   
					(mono)   
					Off - the color burst in the video signal is   
					switched Off in monochrome mode.   
					On - the color burst remains active even in   
					monochrome mode (required by some DVRs   
					and IP encoders).   
					Returns to main menu.   
					EXIT   
					AR18-08-B010 | v1.0 | 2009.03   
					Installation Manual   
					Bosch Security Systems   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					Configuration | en 37   
					5.5.5   
					Enhance / Dynamic Engine submenu   
					Item   
					Selection   
					Description   
					Off: - turns off all automatic scene detail and   
					enhancments (only recommended for   
					testing).   
					Dynamic   
					Engine   
					Off, XF-DYN,   
					2X-DYN,   
					SmartBLC   
					XF-DYN: - extra internal processing is enabled   
					for low-light applications (traffic, etc.).   
					2X-DYN: - 2X-Dynamic adds dual sensor   
					exposure to the XF-DYN features. In harsh   
					lighting conditions pixels from each exposure   
					are mixed to give a more detailed image (use   
					2X-DYN when SmartBLC is not required).   
					SmartBLC: - BLC window and weighting   
					factor are automatically defined. Camera   
					dynamically adjusts these for changing light   
					conditions. Includes all the benefits of 2X-   
					DYN.   
					On, Off   
					Autoblack On automatically increases the   
					visibility of details even when scene contrast   
					is less than full-range due to mist, fog, etc.   
					Autoblack   
					Black level   
					-50 to +50   
					Adjusts the black offset level.   
					A low (negative) value makes the level darker.   
					A high (positive) value makes the level lighter   
					and may bring out more detail in the darker   
					areas.   
					-15 to +15   
					Sharpness   
					Adjusts the sharpness of the picture. 0   
					corresponds to the default position.   
					A low (negative) value makes the picture less   
					sharp. Increasing sharpness brings out more   
					detail.   
					Extra sharpness can enhance the details of   
					license plates, facial features and the edges   
					of certain surfaces.   
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				38 en | Configuration   
					FlexiDome2X   
					Item   
					Selection   
					Description   
					Dynamic noise   
					reduction   
					Auto, Off   
					In AUTO mode the camera automatically   
					reduces the noise in the picture.   
					This may cause some motion blur on   
					exceptionally fast moving objects immediately   
					in front of the camera. This can be corrected   
					by widening the field of view or selecting Off.   
					Peak White   
					Invert   
					On, Off   
					Use Peak White Invert to reduce glare from   
					the CRT/LCD display.   
					Use in ANPR/LPR applications to reduce   
					headlight glare. (Test on-site to ensure that it   
					does benefit the application and is not   
					distracting for operators of the security   
					system.)   
					Returns to main menu.   
					EXIT   
					5.5.6   
					Color submenu   
					Item   
					Selection   
					Description   
					ATW,   
					ATW - Auto tracking white balance allows the   
					camera to constantly adjust for optimal color   
					reproduction.   
					White balance   
					AWBhold,   
					Manual   
					AWBhold - Puts the ATW on hold and saves   
					the color settings.   
					Manual - the Red, Green, and Blue gain can be   
					manually set to a desired position.   
					Fast, Medium,   
					Slow   
					Adjusts the speed of the white balance   
					control loop.   
					Speed   
					ATW and AWBhold - adjusts the Red gain to   
					optimize the white point.   
					Red gain   
					-5 to +5   
					-50 to +50   
					Manual - adjusts the Red gain.   
					AR18-08-B010 | v1.0 | 2009.03   
					Installation Manual   
					Bosch Security Systems   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					Configuration | en 39   
					Item   
					Selection   
					Description   
					ATW and AWBhold - adjusts the B gain to   
					optimize the white point.   
					Blue gain   
					-5 to +5   
					Manual - adjusts the Blue gain.   
					-50 to +50   
					-50 to +50   
					-15 to +5   
					Manual - adjusts the Green gain.   
					Green gain   
					Saturation   
					Adjusts the color saturation. -15 gives a   
					monochrome image.   
					Returns to main menu.   
					EXIT   
					5.5.7   
					VMD submenu   
					Item   
					Selection   
					Description   
					Off, Silent,   
					OSD   
					VMD   
					Off - Video Motion Detection (VMD) is off.   
					Silent - video motion generates silent alarm.   
					OSD - video motion generates on-screen text   
					message alarm.   
					Submenu   
					Select to enter the area set-up menu to define   
					the detection area.   
					VMD area   
					Indicates the peak of measured motion in the   
					selected area. Press either the right, left or   
					center navigation button to reset.   
					Motion   
					indicator   
					Sets the sensitivity for motion to the desired   
					level. The longer the white bar, the more   
					motion is required to acitvate the VMD alarm.   
					Motion above this level triggers alarm.   
					VMD   
					sensitivity   
					Text for on-screen display alarm (16   
					characters maximum).   
					OSD alarm   
					text   
					Alphanumeric   
					Returns to main menu.   
					EXIT   
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				40 en | Configuration   
					FlexiDome2X   
					Selecting an area for VMD masking   
					To set-up an area for VMD masking, access the area menu by   
					selecting the VMD Area option from the VMD menu. Upon   
					entering the Area menu, the current area is displayed with the   
					upper left corner flashing. The flashing corner of the image can   
					be moved with the Up, Down, Left, Right arrow keys. Pressing   
					the Select key moves the flashing cursor to the opposite corner,   
					which can now be moved. Pressing Select again freezes the   
					area and exits the area menu.   
					There is one programmable VMD area.   
					Note:   
					When VMD is enabled, normal light fluctuations or   
					environmental factors can contribute to false-positive alarms.   
					Because of this, it is recommended that you do not connect the   
					VMD-triggered alarm output of the camera to a monitored alarm   
					system as the false-positive alarms may be considered a   
					nuisance.   
					AR18-08-B010 | v1.0 | 2009.03   
					Installation Manual   
					Bosch Security Systems   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					Configuration | en 41   
					5.6   
					Install menu structure   
					Item   
					Selection   
					Submenu   
					Submenu   
					Submenu   
					Submenu   
					Submenu   
					Description   
					Select on-screen display (OSD) language   
					Sets synchronization parameters.   
					Connection parameters   
					Language   
					Synchronization   
					Connections   
					Test signals   
					Camera ID   
					Test patterns and texts   
					Select to access ID submenu   
					Sets up a masking area   
					Privacy masking   
					Default ALL   
					Submenu   
					Submenu   
					Returns all settings for all modes to factory   
					defaults   
					Select to close the Install menu and open the   
					lens wizard. Adjust the focus as described in   
					Section 4.2.3 Focal length and focus.   
					Set backfocus   
					now   
					When finished adjusting, press the Up or   
					Down navigation button to exit the lens   
					wizard and open the Install menu again.   
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				42 en | Configuration   
					FlexiDome2X   
					5.6.1   
					Language submenu   
					Item   
					Selection   
					Description   
					English   
					Spanish   
					French   
					German   
					Portuguese   
					Polish   
					Language   
					Displays the menus on the OSD in the   
					choosen language.   
					Italian   
					Dutch   
					Russian   
					Returns to Install menu.   
					EXIT   
					5.6.2   
					Connections submenu   
					Item   
					Selection   
					Description   
					On, Off   
					Switches notch filter on or off. The notch   
					filter can remove a Moiré pattern or color   
					artifacts caused by closely spaced vertical   
					lines or objects (e.g. vertical security bars   
					over windows).   
					Notch filter   
					Off, Auto   
					On, Off   
					Select Auto to enable the thermostatically   
					controlled heater function. The heater turns   
					on at approximately 0 °C (+32 °F).   
					Heater   
					If Off, Bilinx communications is disabled.   
					Returns to Install menu.   
					Bilinx Comms.   
					EXIT   
					AR18-08-B010 | v1.0 | 2009.03   
					Installation Manual   
					Bosch Security Systems   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					Configuration | en 43   
					5.6.3   
					Test signal submenu   
					Item   
					Selection   
					Description   
					Off, On   
					Select On to overlay the camera ID on the   
					video test signal.   
					Show camera   
					ID   
					Color bars   
					100%,   
					Select the desired test pattern to help   
					installation and fault-finding.   
					Test pattern   
					Grayscale 11-   
					step,   
					Sawtooth 2H,   
					Checker   
					board,   
					Cross hatch,   
					UV plane   
					Returns to Install menu.   
					EXIT   
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				44 en | Configuration   
					FlexiDome2X   
					5.6.4   
					Camera ID submenu   
					Item   
					Selection   
					Description   
					Enter a 17-character camera name. Use   
					Left/Right to change position in the string;   
					use up/down to select character. Use Select   
					to exit.   
					Camera ID   
					Off, Top left,   
					Top right,   
					Display ID pos.   
					Select the screen position of the camera ID.   
					Bottom left,   
					Bottom right   
					On, Off   
					Displays a grey border behind the camera ID   
					to make it easier to read.   
					Camera ID   
					border   
					Shows MAC address (factory set, cannot be   
					changed).   
					MAC address   
					On, Off   
					The ticker bar moves continuously to show   
					that the image is live and not frozen or played   
					back.   
					Ticker bars   
					Off, Top left,   
					Top right,   
					Camera mode is displayed on the screen in   
					the selected position.   
					Display mode   
					ID   
					Bottom left,   
					Bottom right   
					Returns to Install menu.   
					EXIT   
					AR18-08-B010 | v1.0 | 2009.03   
					Installation Manual   
					Bosch Security Systems   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					Configuration | en 45   
					5.6.5   
					Privacy masking submenu   
					Item   
					Selection   
					Description   
					Black, Grey,   
					White, Noise   
					Selects pattern for all masks.   
					Pattern   
					1, 2, 3, 4   
					Mask   
					Four different areas can be masked.   
					Turns each of the four masks on or off.   
					Active   
					Window   
					On, Off   
					Submenu   
					Select to open a window in which to define   
					the mask area.   
					Selecting an area for privacy masking   
					To set-up an area for privacy masking, access the area menu by   
					selecting the Area option from the privacy masking menu. Upon   
					entering the Area menu, the current area is displayed with the   
					upper left corner flashing. The flashing corner of the image can   
					be moved with the Up, Down, Left, Right arrow keys. Pressing   
					the Select key moves the flashing cursor to the opposite corner,   
					which can now be moved. Pressing Select again freezes the   
					area and exits the area menu.   
					There are four programmable privacy mask areas.   
					5.6.6   
					Defaults submenu   
					Item   
					Selection   
					Description   
					No, Yes   
					Restores all settings of the six modes to their   
					default (factory) values. Select YES then   
					press the Menu/Select button to restore all   
					values.   
					Restore All   
					When completed the message RESTORED! is   
					shown.   
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					Troubleshooting | en 47   
					6 
					Troubleshooting   
					6.1   
					Resolving problems   
					The following table is intended to help you identify the causes   
					of malfunctions and correct them when possible.   
					Malfunction   
					Possible causes   
					Solution   
					No image   
					Defective camera.   
					Connect a local monitor   
					to the camera and check   
					the camera function.   
					transmission to   
					remote location.   
					Faulty cable connections. Check all cables, plugs,   
					contacts and   
					connections.   
					When using DC power   
					ensure that polarity is   
					correct.   
					No connection   
					The unit's configuration. Check all configuration   
					parameters.   
					established, no   
					image transmission.   
					Faulty installation.   
					Check all cables, plugs,   
					contacts and   
					connections.   
					6.2   
					Customer service   
					If you cannot resolve a fault, please contact your supplier or   
					system integrator, or contact Bosch Security Systems   
					Customer Service directly.   
					The Installer should write down all information regarding the   
					unit so that it can be referenced for warranty or repair. The   
					version numbers of the firmware and other status information   
					can be seen when the unit starts or by opening the Install   
					menu. Note down this information and the information found   
					on the camera label before contacting customer service.   
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					Maintenance | en 49   
					7 
					Maintenance   
					7.1   
					Repairs   
					CAUTION!   
					Never open the casing of the camera. The unit does not contain   
					any user serviceable parts. Ensure that all maintenance or   
					repair work is performed only by qualified personnel (electrical   
					engineering or network technology specialists). If in doubt,   
					contact your dealer's technical service center.   
					! 
					7.1.1   
					Transfer and disposal   
					The camera should only be passed-on together with this   
					installation guide. The unit contains environmentally hazardous   
					materials that must be disposed of according to law. Defective   
					or superfluous devices and parts should be disposed of   
					professionally or taken to your local collection point for   
					hazardous materials.   
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					Technical Data | en 51   
					8 
					Technical Data   
					8.1   
					Specifications   
					Type number   
					VDN-498V03   
					2.8 to 10 mm   
					VDN-498V09   
					Lens focal   
					length   
					9 to 22 mm   
					F-stop   
					F1.2   
					F1.4   
					Minimum   
					0.28 (0.027) lx (fc) 30IRE   
					0.099 (0.0092) mono   
					0.32 (0.03) lx (fc) 30IRE   
					0.11 (0.01) mono   
					Illumination   
					Active pixels   
					752 x 582 (PAL - 11), 768 x 494 (NTSC - 21)   
					Rated supply   
					voltage   
					24 VAC ( 10%) or   
					+12 VDC ( 10%)   
					All versions   
					Imager   
					1/3-inch interline CCD   
					540 TVL   
					Resolution   
					SNR   
					> 50 dB   
					Video output   
					1 Vpp, 75 Ohm   
					Synchroniza-   
					tion   
					Internal or Line Lock selectable   
					Shutter   
					AES (1/60 [1/50] to 1/10000) customer selectable   
					AES (1/60 [1/50] to 1/15000) automatic   
					flickerless, fixed selectable   
					Day/Night   
					Sens Up   
					AGC   
					Color, Mono, Auto   
					Adjustable from Off to 10x   
					AGC On or Off (0 - 30 dB) selectable   
					Dynamic engine XF-Dynamic, 2X-Dynamic, SmartBLC   
					DNR   
					Automatic noise filtering On/Off selectable   
					Sharpness enhancement level selectable   
					Sharpness   
					White Balance ATW, AWBhold and manual (2500 to 10000K)   
					Color   
					Adjustable from monochrome (0%) to 133% color   
					saturation   
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				52 en | Technical Data   
					FlexiDome2X   
					ALC lens   
					DC iris   
					Color bars 100%, Greyscale 11-step, Sawtooth 2H,   
					Test pattern   
					generator   
					Checker board, Cross hatch, UV plane   
					One area, fully programmable   
					Video Motion   
					Detection   
					(VMD)   
					Privacy   
					Four independent areas, fully programmable; black,   
					white, grey, noise   
					Masking   
					Communication Two-way Bilinx (bi-directional)   
					Languages   
					(OSD)   
					English, Spanish, French, German, Portuguese, Polish,   
					Italian, Dutch, Russian   
					Modes   
					6 programmable (preset) modes: 24-hour, Traffic, Low-   
					light, SmartBLC, Low noise, Analogue systems   
					Peak White   
					Invert   
					Suppresses highlights in scenes   
					Misc.   
					Notch filter, Actual AGC, Actual shutter, IR contrast   
					Power   
					12 VDC 400 mA   
					24 VDC 330 mA   
					consumption   
					Weight   
					550 g (1.21 lb)   
					Operating   
					-30 °C to +55 °C (-22 °F to +131 °F)   
					(-50 °C [-58 °F] with heater enabled)   
					temperature   
					Controls   
					OSD with softkey operation   
					AR18-08-B010 | v1.0 | 2009.03   
					Installation Manual   
					Bosch Security Systems   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					Technical Data | en 53   
					8.1.1   
					Dimensions   
					57.6 (2.27)   
					57.6 (2.27)   
					121 (4.77)   
					95 (3.7)   
					mm (in)   
					158 (6.22)   
					Figure 8.1 Dimensions - Flush-mount   
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				54 en | Technical Data   
					FlexiDome2X   
					53.3 (2.1)   
					53.3 (2.1)   
					121 (4.77)   
					158 (6.22)   
					mm (in)   
					Figure 8.2 Dimensions - Surface-mount   
					AR18-08-B010 | v1.0 | 2009.03   
					Installation Manual   
					Bosch Security Systems   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					Technical Data | en 55   
					8.1.2   
					Accessories   
					– 
					– 
					– 
					– 
					– 
					BNC to UTP transceiver   
					Surface Mount Box (SMB)   
					Pendant wall mount   
					Pendant ceiling mount   
					Corner mount   
					– 
					Bilinx communication interface box and software   
					Contact a Bosch representative in your area for the latest   
					available accessories or visit our website at   
					
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					| en 57   
					Glossary   
					A 
					AES   
					Automatic Electronic Shutter (see Electronic iris).   
					Aperture   
					The size of the opening in the lens iris that controls the amount   
					of light reaching the CCD Sensor. The larger the F-number, the   
					less light reaches the sensor. An increase of one F-stop, halves   
					the amount of light reaching the sensor.   
					AutoBlack   
					A technique of boosting the video signal level to produce a full   
					amplitude video signal, even when the scene contrast is less   
					than full range (glare, fog, mist, etc.).   
					Automatic Gain Control (AGC)   
					The electronics that regulate the gain or amplification of the   
					video signal. AGC is used in low-light conditions with the iris   
					fully open.   
					AutoIris   
					The lens iris opening is automatically adjusted to allow the   
					correct illumination of the camera sensor. With a direct drive   
					(DC) iris lens, the camera controls the aperture size. A video iris   
					lens has the control circuit in the lens itself.   
					Auto Level Control (ALC)   
					The adjustment of the video level to give the desired brightness   
					level. This can be done electronically or by means of an iris   
					control.   
					Auto White Balance (AWB)   
					A feature that allows a color camera to automatically adjust its   
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				58 en |   
					FlexiDome2X   
					output color to give a natural color, independent of the lighting   
					used.   
					B 
					Backfocus   
					Bilinx   
					The distance between the image plane and the rear portion of   
					the lens. Correct backfocus adjustment ensures that the   
					camera remains in focus under various conditions.   
					A communications protocol that allows remote control,   
					configuration, and updates to be performed over the video   
					cable (Coax or Passive UTP).   
					Bilinx address   
					The address may be set locally using the Bilinx Configuration   
					Tool for Imaging Devices (CTFID).   
					Back Light Compensation (BLC)   
					Selectively amplifies parts of the image to compensate for large   
					contrast differences when only a portion of the image is brightly   
					lit (e.g. a person in a sunlit doorway). See also Smart BLC.   
					C 
					Charged Coupled Device (CCD)   
					A CCD is a type of solid state image sensor used in CCTV   
					cameras. The sensor converts light energy into electrical   
					signals.   
					CCD Format   
					Indicates the size of the camera sensor used. In general, the   
					larger the sensor, the more sensitive the camera and the better   
					the image quality. The format is quoted in inches, for example   
					1/3 or 1/2 inch.   
					Color Temperature   
					A measure of the relative color of illumination. Generally used   
					AR18-08-B010 | v1.0 | 2009.03   
					Installation Manual   
					Bosch Security Systems   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					| en 59   
					to specify the color balance correction of a camera to achieve a   
					natural color image.   
					D 
					Day/Night (infrared sensitive)   
					A camera that has normal color operation in situations where   
					there is sufficient illumination (day conditions), but where the   
					sensitivity can be increased when there is little light available   
					(night conditions). This is achieved by removing the infrared cut   
					filter required for good color rendition. The sensitivity can be   
					further enhanced by integrating a number of fields to improve   
					the signal-to-noise ratio of the camera (this may introduce   
					motion blur).   
					Default Shutter   
					A feature allowing the shutter speed to be set to a fast speed to   
					eliminate motion blur and provide a detailed and clear image of   
					fast-moving objects while there is sufficient light. When light   
					levels fall and other adjustments have been exhausted, the   
					shutter speed reverts to the standard setting to maintain   
					sensitivity.   
					Depth of Field   
					The distance from the nearest to the furthermost point that   
					appears in focus. The smaller the aperture, the greater the   
					depth of field.   
					Dynamic Noise Reduction (DNR)   
					A digital video processing technique that measures the noise   
					(image artifacts) in the picture and automatically reduces it.   
					E 
					Electronic iris   
					Electronic iris (or AES - Automatic Electronic Shutter) adjusts   
					the camera shutter speed to compensate for lighting changes.   
					In some cases this can eliminate the need for an autoiris lens.   
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				60 en |   
					FlexiDome2X   
					F 
					F-Number   
					The standard measure of the lens aperture, which is the iris   
					diameter, divided by the focal length of the lens. The lower the   
					maximum aperture (F-Number or F-Stop), the more light that   
					passes through the lens.   
					F-Stop   
					See F-Number   
					Field of View   
					The measure of the visible area within the camera’s field of   
					view. The larger the focal length, the smaller the field of view.   
					The smaller the focal length, the wider the field of view.   
					Focal Length   
					The distance from the optical center of the lens to the image of   
					an object located at an infinite distance from the lens. Long   
					focal lengths give a small field of view (e.g. telephoto effect),   
					while short focal lengths give a wide angle view.   
					I 
					Infrared Illumination   
					Electromagnetic radiation (light) with a longer wavelength than   
					is visible to the human eye. IR illumination is prominent at dusk   
					and dawn and in incandescent lamps. IR illuminators come in   
					the form of lamps with the appropriate filters, LEDs, or lasers.   
					CCD sensors are less sensitive to IR than visible light, but IR   
					can significantly increase the total illumination level, leading to   
					a much better image at low light levels.   
					IRE (Institute of Radio Engineers)   
					A measurement of video amplitude that divides the area from   
					the bottom of sync to peak white level into 140 equal units -   
					140 IRE equals 1V peak-to-peak. The range of active video is   
					100 IRE.   
					AR18-08-B010 | v1.0 | 2009.03   
					Installation Manual   
					Bosch Security Systems   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					Lens wizard   
					| en 61   
					L 
					The lens wizard is used when setting the backfocus. It opens   
					the iris fully while maintaining the correct video level using AES.   
					Lux   
					The international (SI) unit of measurement of the intensity of   
					light. It is equal to the illumination of a surface one meter away   
					from a single candle.   
					O 
					OSD   
					On-screen Display: Menus are shown on the display monitor.   
					P 
					Privacy Masking   
					The ability to mask out a specific area to prevent it from being   
					viewed in order to comply with privacy laws and particular site   
					requirements.   
					PWIE   
					Peak White Inverse Engine: White highlights are automatically   
					turned black to reduce bright spots. Useful in traffic and car   
					park applications.   
					R 
					Region of Interest   
					A specific area within a field of view, used by the motion   
					detection algorithm to identify motion.   
					Resolution   
					The measure of the fine detail that can be seen in an image. For   
					analog systems this is typically measured in horizontal   
					Television Lines or TVL. The higher the TVL rating, the higher   
					the resolution.   
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				62 en |   
					FlexiDome2X   
					S 
					Saturation   
					The amplitude of the chrominance signal affecting the vividness   
					of the color.   
					Sensitivity   
					A measure of the amount of light required to provide a standard   
					video signal. Sensitivity values are stated in lux (see Lux).   
					SensUp (sensitivity up)   
					Increases camera sensitivity by increasing the integration time   
					on the CCD (lowering shutter time from 1/50 s to 1/5 s in PAL   
					or 1/60 s to 1/6 s in NTSC). This is accomplished by integrating   
					the signal from a number of consecutive video fields to reduce   
					signal noise.   
					Signal-to-noise ratio   
					The ratio between a useful video signal and unwanted noise   
					measured in dB.   
					Smart BLC (Back Light Compensation)   
					Smart back-light compensation allows the camera to   
					automatically compensate for bright areas of a high contrast   
					scene without having to define a window or area.   
					U 
					UTP (Unshielded Twisted Pair)   
					A variant of twisted pair cabling, UTP cable is not surrounded   
					by any shielding. The wires in a twisted pair cable are twisted   
					around each other to minimize interference from the other   
					twisted pairs in the cable. UTP is the primary wire type for   
					telephone usage and the most commonly used type of   
					networking cable.   
					AR18-08-B010 | v1.0 | 2009.03   
					Installation Manual   
					Bosch Security Systems   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FlexiDome2X   
					VMD   
					| en 63   
					V 
					Video Motion Detection: An algorithm for motion detection in   
					which the camera compares the current image with a reference   
					image and counts the number of pixels that have changed   
					between the two images. An alarm is generated when the   
					number of pixel changes exceeds a user-configured threshold.   
					W 
					WDR (Wide Dynamic Range)   
					A camera’s dynamic range is the difference between the   
					minimum and maximum acceptable signal levels. A scene with   
					both very low and very high illumination levels requires a   
					camera with a wide dynamic range to handle it correctly and   
					produce a useful image.   
					Bosch Security Systems   
					Installation Manual   
					AR18-08-B010 | v1.0 | 2009.03   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Download from Www.Somanuals.com. All Manuals Search And Download.   
				Bosch Security Systems   
					
					© Bosch Security Systems, 2009   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 |