Bosch Appliances Home Security System IVMD 10 User Manual

IVMD 1.0  
Intelligent Video Motion Detection  
en  
Configuration Instructions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Copyright  
This manual is copyright protected by  
Bosch Security Systems. All rights reserved. No part of this  
document may be reproduced or transmitted for any  
purpose, by whatever method and by whatever means,  
electronically or mechanically, without the express written  
permission of Bosch Security Systems.  
Issue: April 2006 (Software version 1.0)  
© Copyright 2006 Bosch Security Systems  
Note  
This manual has been prepared with all due care and all  
information contained in it has been thoroughly checked. The  
description was complete and correct at the time of going to  
press. Our products are constantly developed and upgraded;  
as such, the content of the manual is subject to change  
without notice. Bosch Security Systems accepts no liability  
for losses that arise directly or indirectly as a result of errors,  
incompleteness or discrepancies between the manual and  
the product described.  
Trade marks  
All of the hardware and software names used in this manual  
are highly likely to be registered trade marks and must be  
treated as such.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IVMD | Configuration instructions  
Table of Contents  
1
2
2.1  
2.1.1  
2.2  
3
3.1  
4
4.1  
4.2  
4.2.1  
4.2.2  
4.2.3  
4.3  
4.3.1  
4.3.2  
4.4  
The Area settings window . . . . . . . . . . . . . . . . . . . . . . . . . . . 15  
Detector field context menu . . . . . . . . . . . . . . . . . . . . . . . . . 18  
Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21  
Adjusting the calibration plane. . . . . . . . . . . . . . . . . . . . . . . . 23  
Viewing and editing calibration settings . . . . . . . . . . . . . . . . 25  
Properties of a detector field. . . . . . . . . . . . . . . . . . . . . . . . . 28  
Sensitive area. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33  
Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36  
4.5  
4.6  
5
6
Display of Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38  
Contact and Service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39  
Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41  
BOSCH Security Systems  
1.0 | 2006.04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2
en | Table of Contents  
IVMD | Configuration instructions  
1.0 | 2006.04  
BOSCH Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IVMD | Configuration instructions  
Introduction | en  
3
1
Introduction  
IVMD (Intelligent Video Motion Detection) is a software  
algorithm that detects movements of objects within an environ-  
ment monitored by a video camera and generates alarm events  
that can be processed further in a CCTV system.  
IVMD makes it possible to capture and evaluate directional  
movement of objects, thereby largely preventing false alarms.  
IVMD adapts automatically to changing environmental condi-  
tions and is therefore non-sensitive to perturbing influences  
such as rain and tree movement.  
BOSCH Security Systems  
1.0 | 2006.04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4
en | Introduction  
IVMD | Configuration instructions  
1.0 | 2006.04  
BOSCH Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IVMD | Configuration instructions  
Requirements | en 5  
2
Requirements  
You will need the Configuration Manager software to configure  
IVMD. This must be installed on a Windows PC that can commu-  
nicate with the respective device over a network.  
2.1  
License  
When you purchase IVMD you are given an Authorization Num-  
ber.  
Together with the Installation code, which you can find in the  
Web browser view, you generate the Activation Key on our  
Internet platform.  
This key is then entered in the Web browser view. Thereafter  
you can use IVMD.  
1. Open the Web browser view of the device.  
2. Select SETTINGS > Service settings > Licenses:  
You will find the Installation code here.  
BOSCH Security Systems  
1.0 | 2006.04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
6
en | Requirements  
IVMD | Configuration instructions  
2.1.1  
Requesting the Activation Key  
3. Connect to the Internet on a PC and open this page in a  
Web browser:  
(this page always appears in English)  
You will see the BOSCH Security Systems License Man-  
ager.  
4. If you already have an account, log in.  
You can create a new account if you wish. One of the bene-  
fits of an account is that you can list all of your previous  
license activations.  
You can also continue the process without logging in.  
5. Once you have logged in, the welcome dialog will appear.  
6. Next, you will see the License Activation screen. Enter  
your Authorization Number then click the check mark next  
to the input window.  
7. The next step is to enter your Installation Code.  
Entering an installation site and comments is optional.  
This information will assist you later in assigning the Acti-  
vation Key to the device.  
8. Click Submit. The Activation Key is displayed.  
You can copy the key to the clipboard.  
You can have the key e-mailed to you.  
You can print the page.  
1.0 | 2006.04  
BOSCH Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
IVMD | Configuration instructions  
Requirements | en 7  
9. If you have clicked the Email Activation Key link, you will  
see a dialog in which you can enter two e-mail addresses  
for recipients.  
10. Open the Web browser view of the device again.  
11. Select SETTINGS > Service settings > Licenses again.  
12. Enter the Activation key – copy&paste is supported.  
13. Click Set to save the Activation key. A window tells you  
that installation was successful.  
14. Close the window. IVMD is now activated.  
The Activation key can no longer be seen.  
2.2  
Limitations  
Please note the following considerations:  
IVMD is suitable for monitoring boundaries, fences and enclo-  
sures and for the protection of pipelines, overland lines etc.  
However, in certain environments the use of this type of motion  
detection system may not always be advisable; this is because  
movements may not always be detected or too many move-  
ments may be detected owing to reflections.  
Movements may be falsely detected if there is:  
a reflective metal background  
glass (glazed building frontages)  
water as a background  
Large areas of reflected light can also cause spurious motion  
detection. However, light reflections caused by falling rain-  
drops, for example, are small enough to be ignored for statisti-  
cal purposes and owing to the uniform nature of their motion.  
Objects that always move uniformly (such as clouds) do not  
impair the detection of other objects and do not trigger false  
alarms.  
A constant background is necessary in order to detect motion  
reliably and to assign that motion to a certain object. The more  
the background moves, the harder it is to distinguish moving  
objects from it. For instance, a person walking in front of a  
hedge that is moving in the wind will very probably not be  
detected.  
BOSCH Security Systems  
1.0 | 2006.04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
8
en | Requirements  
IVMD | Configuration instructions  
If the image consists to a certain extent of nothing but moving  
objects – in other words if objects cannot be distinguished  
from each other or from the background – the motion of an indi-  
vidual object cannot be detected (e.g. individuals in a large  
crowd).  
If a very large number of objects are detected, a lot of comput-  
ing power will be required – this will reduce the power that is  
available for the transmission of live video data. If necessary,  
change the settings so that only relevant objects are detected.  
IVMD and the associated configuration menus offer a number of  
simple ways to overcome these limitations and eliminate prob-  
lem areas.  
This means that you will be able to use IVMD reliably in a wide  
range of applications.  
1.0 | 2006.04  
BOSCH Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IVMD | Configuration instructions  
Configuration | en 9  
3
Configuration  
IVMD can only be configured with the Configuration Manager.  
The Configuration Manager can be installed on any  
Windows PC.  
NOTE!  
The system requirements and operation of the Configuration  
Manager are described in the Installation and Operating Manual  
for the Configuration Manager. You can access online help for  
the software by selecting Help > Index when you are in the  
Configuration Manager.  
i
1. Start the Configuration Manager.  
2. On the Network main tab, select the device for which you  
wish to configure IVMD.  
3. In the display area, click the VCA tab to switch to Video  
content analysis.  
BOSCH Security Systems  
1.0 | 2006.04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
10 en | Configuration  
IVMD | Configuration instructions  
3.1  
VCA tab (Video content analysis)  
The camera image appears on the right. You see an individual  
image that is refreshed at regular intervals. As soon as the anal-  
ysis is activated, meta data is generated and depending on the  
configuration the additional information is overlaid on top of  
the image – an object bounding box for example.  
1. Move the camera to the required position.  
NOTE!  
All of the settings you make relate to the selected camera posi-  
tion. This means that you must reconfigure IVMD for this cam-  
era whenever you change the camera's direction or position.  
i
2. Activate the analysis. Otherwise alarm events are not out-  
put for further processing.  
3. Select IVMD 1.0 under Analysis type.  
4. If you are configuring IVMD for a camera for the first time,  
select suitable initial settings for all parameters by clicking  
Default settings. You should also do this if you have  
changed the camera's position or direction.  
5. Click Select area...  
The Area settings window opens. IVMD is configured using  
this window.  
You will find full details in the next section.  
1.0 | 2006.04  
BOSCH Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
IVMD | Configuration instructions  
Configuration | en11  
Alarm state  
This field shows whether IVMD has generated an alarm event  
with the current settings.  
Object markings  
Objects that generate an alarm event under the current settings  
appear on the camera image inside a red outline.  
Objects that are detected as moving but do not generate an  
alarm event under the current settings appear inside a yellow  
outline.  
Object (yellow)  
(No alarm event generated)  
Object (red)  
(Alarm event generated)  
NOTE!  
These object outlines are displayed in real time and are always  
synchronized exactly with the moving object. However, because  
the camera image is not live video feed, the outline does not  
always exactly surround the object.  
i
BOSCH Security Systems  
1.0 | 2006.04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
12 en | Configuration  
IVMD | Configuration instructions  
1.0 | 2006.04  
BOSCH Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IVMD | Configuration instructions  
Area settings | en 13  
4
Area settings  
4.1  
The basics  
The camera 'sees' a selected area that is displayed as a single,  
constantly refreshed image.  
Objects  
Objects are typically people or vehicles moving within the area  
seen by the camera. Objects can be filtered according to cer-  
tain properties (size, direction of movement, speed, location).  
An alarm event can be generated if objects match certain  
parameters. Objects that do not match the criteria you define  
are filtered out and do not generate an alarm event.  
It is always the center of an object that is relevant for generat-  
ing an alarm event.  
Detector fields  
Detector fields are polygons that cover a certain area, for exam-  
ple an entrance or the open space in front of a barrier. These  
detector fields are defined by you. Moving objects that are out-  
side the detector fields will be detected as such but will not  
generate an alarm event. Objects that move inside detector  
fields or across detector field boundaries (depending on your  
settings) will generate an alarm event.  
Sensitive area  
The scene that is captured by a camera often includes areas  
that are irrelevant for alarm event generation (such as sky).  
You can reduce the size of the area that is actually analyzed for  
motion. This will make motion detection for the remaining –  
sensitive – area all the faster and more effective.  
BOSCH Security Systems  
1.0 | 2006.04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
14 en | Area settings  
IVMD | Configuration instructions  
Calibration  
If you wish to filter out objects according to their size or speed,  
for each camera position a link must be made between the size  
of the real-life situation and the dimensions as they appear on  
the camera image. For example, you must tell the software that  
an object that appears on the camera image with a height of  
50 pixels is around 2 m high in reality. The camera angle is used  
to compute object speeds. The calibration mode is available for  
this operation.  
NOTE!  
Display of measurements can be adjusted, so that when using  
the English software interface imperial measurements are  
shown. You will find additional information in Section 5 Display  
of Measurements, page 38.  
i
Filter hierarchy  
Below is an overview of the filter methods. You will find a  
description of the filters in the following sections.  
Sensitive area  
Global settings  
Objects outside the sensitive area are  
ignored.  
Objects that are smaller than the min-  
imum size setting or larger than the  
maximum size setting are ignored.  
Detector field  
Only objects with their center (center  
of gravity) inside the detector field  
are detected.  
Properties  
Objects are filtered out based on  
their properties. Different properties  
can be defined separately for each  
detector field.  
of the detector field  
1.0 | 2006.04  
BOSCH Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IVMD | Configuration instructions  
Area settings | en 15  
4.2  
The Area settings window  
If you have previously reset all the settings to their defaults, the  
Area settings window will display a square detector field that  
covers almost the entire image:  
NOTE!  
All configuration commands can be found in context menus.  
A context menu provides different commands depending on, for  
example, whether you right click inside or outside a detector  
field.  
i
The Area settings window can be enlarged by dragging the bot-  
tom right hand corner of the window with the mouse.  
NOTE!  
Changes to settings are immediately active but are only perma-  
i
nently saved when you click OK.  
BOSCH Security Systems  
1.0 | 2006.04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
16 en | Area settings  
IVMD | Configuration instructions  
4.2.1  
Detector field  
Detector fields are displayed as framed areas with a grid pat-  
tern. The particular status of a detector field is indicated by the  
different colors:  
Green field  
Detector field in which no object that gener-  
ates an alarm event was detected.  
Light green Detector field is clicked and activated for edit-  
ing.  
Green  
Mouse cursor is over the detector field; right  
click to see the context menu for the detector  
field.  
Dark green Mouse cursor is not over this detector field;  
right click to see the general context menu for  
setting an area (or the context menu of another  
detector field).  
Red field  
Detector field in which an object that gener-  
ates an alarm event was detected.  
Light red  
Red  
Detector field is clicked and activated for edit-  
ing.  
Mouse cursor is over the detector field; right  
click to see the context menu for the detector  
field.  
Dark red  
Mouse cursor is not over this detector field;  
right click to see the general context menu for  
setting an area (or the context menu of another  
detector field).  
When you click a detector field, its 'nodes' (corners) are high-  
lighted by circles and you can edit the detector field.  
Nodes can be inserted or deleted. The sides and nodes of a  
detector field can be repositioned as desired. However, the  
sides of a detector field must not cross over, and distorted  
fields are not accepted.  
Detector fields can be copied and inserted.  
1.0 | 2006.04  
BOSCH Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
IVMD | Configuration instructions  
Area settings | en 17  
Moving the mouse cursor over a node highlights it more  
brightly:  
You can reposition the node using drag&drop.  
You can delete the node using the context menu.  
Moving the mouse cursor over a side highlights it more brightly:  
You can reposition the side using drag&drop.  
You can insert a node using the context menu.  
Up to 16 detector fields each with up to 16 nodes can be cre-  
ated for each camera image.  
For each detector field you can specify that only objects with  
certain properties will trigger an alarm event. These config-  
urable properties include:  
the speed at which the object is moving  
the motion of the object relative to the detector field  
(inside, leaving, entering)  
the direction in which the object is moving  
the size of the object (the area covered)  
For example, you can configure the monitoring of an entrance  
and exit so that only large, fast-moving vehicles leaving the  
detector field trigger an alarm. Small, slow-moving people will  
not trigger an alarm.  
BOSCH Security Systems  
1.0 | 2006.04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
18 en | Area settings  
IVMD | Configuration instructions  
4.2.2  
Detector field context menu  
Overview of commands:  
Cut  
Deletes the detector field – the field is  
copied to the clipboard and can be  
inserted again if required.  
Copy  
Copies the field to the clipboard.  
Insert Node  
Inserts a node on the side over which the  
mouse cursor is positioned.  
Delete Node  
Statistics  
The node on which the mouse cursor is  
positioned is deleted.  
Shows the statistics for the detector field  
(Section 4.6 Statistics, page 36).  
Properties  
Shows the properties for the detector  
field (Section 4.4 Properties of a detector  
field, page 28).  
1.0 | 2006.04  
BOSCH Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
IVMD | Configuration instructions  
Area settings | en 19  
4.2.3  
Area settings context menu  
This context menu appears in the Area settings window when  
you right click outside a detector field in the camera image.  
Overview of commands:  
Paste  
Inserts the detector field copied to the clip-  
board.  
Create Detector Creates a new detector field.  
Field  
Calibrate  
View  
Switches to calibration mode  
(see Section 4.3 Calibration, page 21).  
Edit Sensitive  
Area  
Switches to the mode for editing the sensitive  
area (see Section 4.5 Sensitive area, page 33).  
Show  
Show or hide:  
Sensitive area  
Object outline  
Object bounding box  
Detector fields  
Direction filter  
The checked options are shown in the Config-  
uration Manager and on the Video content  
analysis configuration page in the Web  
browser view for the device. If you wish to  
view the options on the Web browser livep-  
age as well, you must check the Show VCA  
metadata option on the Livepage configura-  
tion page of the Web browser view.  
BOSCH Security Systems  
1.0 | 2006.04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
             
20 en | Area settings  
IVMD | Configuration instructions  
Global Settings Here you can specify a minimum and maxi-  
mum size for all objects that will generate an  
alarm event. Objects that are smaller or larger  
than the specified sizes will be ignored and  
this will save computing power as a result.  
Make sure that the range between the mini-  
mum and maximum size is not too small, or  
relevant objects may be unintentionally elimi-  
nated from alarm generation.  
Preview: Shows the calibration plane  
(see page 23). You will also see two nested  
cubes that symbolize the selected sizes  
according to the calibration. You can use the  
mouse to change the size of the cubes and  
hence the settings for the minimum and maxi-  
mum size.  
1.0 | 2006.04  
BOSCH Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
IVMD | Configuration instructions  
Area settings | en 21  
4.3  
Calibration  
Calibration is only necessary if you want the speed and size of  
detected objects to be interpreted correctly. You do not need  
to perform this step if you do not want objects to be filtered on  
the basis of these two properties.  
In the calibration mode, a virtual horizontal plane is overlaid on  
top of the camera image:  
The virtual plane appears as a blue grille and can be tilted,  
rotated and scaled. Position the virtual plane on the camera  
image so that it matches the angle and perspective of one of  
the actual horizontal areas.  
NOTE!  
Display of measurements can be adjusted, so that when using  
the English software interface imperial measurements are  
shown. You will find additional information in Section 5 Display  
of Measurements, page 38.  
i
Two red cubes are shown at opposite corners of the plane.  
In the default setting, the side length of one of these cubes is  
equivalent to 2 meters, so the cube is about the same height as  
a person. The cubes are shown in the perspective of the blue  
plane.  
You can adjust the position and size of the cubes – so that a  
cube corresponds to a car, for example.  
A section of a street is a suitable reference area, especially if  
the sides of the street are marked.  
BOSCH Security Systems  
1.0 | 2006.04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
22 en | Area settings  
IVMD | Configuration instructions  
Position one of the red cubes over an object that you wish to  
trigger an alarm event. Adjust the cube to the size of this object.  
The second cube changes its size to suit the selected perspec-  
tive. You can place the second cube over another object of the  
same type, for example a second person who is further back in  
the image.  
The more care you take over calibration, the more accurately  
the size, direction and speed of moving objects can be esti-  
mated.  
You can of course alter your settings at any time.  
NOTE!  
The system must be recalibrated each time the camera position  
is changed.  
i
1.0 | 2006.04  
BOSCH Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IVMD | Configuration instructions  
Area settings | en 23  
4.3.1  
Adjusting the calibration plane  
This section provides an overview of the ways in which the cali-  
bration plane can be adjusted. Move the mouse cursor over an  
anchor point or a line and then perform the required action  
while holding down the left mouse button.  
Start position  
At the beginning, the calibration plane  
is shown upright.  
Anchor point  
The calibration plane is scaled.  
Center of a side line of  
the plane  
Anchor point  
The entire calibration plane is moved.  
Center of the plane  
One of the lines of the The calibration plane is tilted horizon-  
plane that is horizontal tally; the tilt angle is changed. Refer to  
in the start position  
the description of the settings on  
page 26.  
One of the lines of the The calibration plane is tilted vertically;  
plane that is vertical in the roll angle is changed. Refer to the  
the start position  
description of the settings on page 26.  
Anchor point  
The calibration plane is rotated.  
Corner of the plane  
BOSCH Security Systems  
1.0 | 2006.04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
24 en | Area settings  
IVMD | Configuration instructions  
Anchor point  
The size of both cubes changes – both  
cubes always represent the same size.  
Corner of a cube  
Line of a cube  
The cube can be positioned as desired.  
The calibration mode also provides a context menu with the fol-  
lowing commands:  
Save and Exit  
Calibration  
The settings are saved. You leave the cali-  
bration mode.  
Cancel Calibration You leave the calibration mode without  
saving the settings.  
Reset  
You stay in calibration mode; all settings  
are reset to their original status.  
Center Cubes  
Settings  
Both cubes are positioned centrally on  
the calibration plane.  
Shows the calibration settings.  
You can change the settings by entering  
values. This is described in the next sec-  
tion.  
1.0 | 2006.04  
BOSCH Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
IVMD | Configuration instructions  
Area settings | en 25  
4.3.2  
Viewing and editing calibration settings  
The context menu for the calibration mode allows you to view  
the current calibration settings.  
In the Calibration Settings dialog box you can change the set-  
tings of each parameter simply by entering the required values.  
Tilt angle:  
The angle between the horizontal and the camera.  
BOSCH Security Systems  
1.0 | 2006.04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
26 en | Area settings  
IVMD | Configuration instructions  
Roll angle:  
The angle by which the calibration plane is tilted.  
The setting can deviate from the horizontal by up to 10 degrees.  
Elevation:  
The vertical distance from the camera to the ground plane of  
the captured image – typically the height of the mounted cam-  
era above the ground (in meters).  
Camera constant:  
The camera constant determines the basic settings for calibra-  
tion. The default value of 1000 is preset and should only be  
adjusted if the actual camera constant significantly deviates  
from this preset. The camera constant is used to compensate  
spherical distortions from the combination of image sensor and  
lens.  
The camera constant is a function of the focal length of the  
camera's lens and the pixel pitch of the image sensor. It is cal-  
culated with the following formula:  
Camera constant = focal length [mm]/(pixel pitch [mm] x 4)  
1.0 | 2006.04  
BOSCH Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
IVMD | Configuration instructions  
Area settings | en 27  
The pixel pitch is obtained by dividing the image sensor size by  
the number of pixels. For sensors with 596 pixels, for example,  
this gives:  
1/2 inch: 5.95 mm/596 = 0.0100 mm  
1/3 inch: 4.96 mm/596 = 0.0083 mm  
1/4 inch: 3.69 mm/596 = 0.0062 mm  
For such a 1/4 inch image sensor with a 28 mm lens:  
camera constant = 28 mm/(0.0062 mm x 4) = 1129  
For a 1/3 inch sensor with a 12 mm lens:  
camera constant = 12 mm/(0.0083 mm x 4) = 361  
NOTE!  
If you change the camera constant, you must also change the  
size of the cubes to suit the actual relative sizes in the image.  
i
Cube size:  
Side length of the cubes (in meters).  
A side length of 2 m (6 ft) corresponds approximately to the  
height of a person.  
BOSCH Security Systems  
1.0 | 2006.04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
28 en | Area settings  
IVMD | Configuration instructions  
4.4  
Properties of a detector field  
The Properties of Detector Field dialog is opened from the  
context menu of the Area settings window (refer to page 19).  
In the dialog you can specify the properties of objects for which  
this detector field will generate an alarm event. Objects that do  
not match the selections made here will not trigger an alarm. In  
other words: Objects are filtered according to their properties.  
Only objects that match all filter criteria can trigger an alarm  
event (filter criteria are logically linked with AND).  
Meaningful settings will help to prevent false alarms. If you are  
concerned that objects will not generate an alarm event even  
though this would be desirable for those objects, refer to the  
descriptions given in Section 4.6 Statistics, page 36.  
1.0 | 2006.04  
BOSCH Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
IVMD | Configuration instructions  
Area settings | en 29  
Objects cannot be detected according to their properties  
unless the system has been calibrated for the current camera  
position (Section 4.3 Calibration, page 21).  
Object size filter  
Only objects whose size (captured area) is between the  
entered limits can lead to the generation of an alarm event.  
A person corresponds to around 0.5 m²; a car to  
around 4 m².  
Objects are not filtered by size.  
Object motion filter  
Only objects moving at a speed between the entered limits  
can lead to the generation of an alarm event.  
The speed of a movement crossways to the camera can be  
determined much more accurately than the speed of a  
movement directly toward or away from the camera.  
Objects are not filtered by speed.  
Object moves crossways to camera:  
speed is detected more accurately  
Object moves in camera’s line of sight:  
speed is detected less accurately  
NOTE!  
Select generous filter settings for object size and speed so that  
all relevant movements lead to an alarm being generated.  
i
BOSCH Security Systems  
1.0 | 2006.04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
30 en | Area settings  
IVMD | Configuration instructions  
Trigger  
Mode:  
An alarm event is generated when...  
Entering  
...the center of the object moves across the  
boundary of the detector field and into the  
field.  
Debounce time: If a value other than 0  
(zero) is selected, the alarm event will not  
be generated until the center of the object  
has fully crossed the boundary of the  
detector field after this time. This prevents  
objects triggering a large number of alarm  
events when they are moving around on  
the edge of the detector field.  
Leaving  
Inside  
...the center of the object moves across the  
boundary of the detector field and out of  
the field.  
Debounce time: as for entering objects,  
see above.  
...the center of the object moves inside the  
detector field.  
Delay [s]: If a value other than 0 (zero) is  
selected, the alarm event will not be gener-  
ated until the object has moved or been  
inside the detector field for at least the  
selected delay time.  
NOTE!  
If the boundary of the detector field lies across a static object  
that can conceal a moving object (e.g. advertising hoarding),  
entering or leaving may not be detected.  
i
1.0 | 2006.04  
BOSCH Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
IVMD | Configuration instructions  
Area settings | en 31  
Object direction filter  
Off  
Objects are not filtered according to  
their direction of movement  
On  
Objects will only generate an alarm  
event when they move in the selected  
direction.  
A tolerance angle is entered for the  
direction.  
Dual  
Objects will only generate an alarm  
event when they move in one of the  
selected directions.  
A tolerance angle is entered for each  
direction.  
NOTE!  
Only use the speed and direction filters for detecting truly sig-  
nificant movements; select your settings to ensure the most  
robust results possible.  
i
BOSCH Security Systems  
1.0 | 2006.04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
32 en | Area settings  
IVMD | Configuration instructions  
If you have activated Direction under Show in the context menu  
of the Area settings window (see page 19), the direction filter  
and the motion filter will be graphically displayed for each  
detector field:  
90°  
Tolerance angle  
180°  
Direction: here 0°  
is counted counter-  
clockwise starting from  
East.  
270°  
The direction field can also be repositioned with the mouse in  
the graphic display.  
You can change the tolerance angle with the mouse by moving  
the cursor directly onto the side of the direction indicator and  
then moving it with drag&drop.  
1.0 | 2006.04  
BOSCH Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IVMD | Configuration instructions  
Area settings | en 33  
An object motion filter (if set) is shown by additional moving  
white (maximum limit) and yellow (minimum limit) squares  
being displayed inside the direction indicator.  
NOTE!  
Grapic display is adjusted to the size of the detector. For better  
visibility, either create a detector large enough or resize the  
whole window.  
i
4.5  
Sensitive area  
The sensitive area is that part of the image seen by the camera  
that is analyzed. Objects moving outside the sensitive area can-  
not generate an alarm event even if they are caught by the cam-  
era.  
Only objects moving inside the sensitive area are detected as  
such and generate an alarm event.  
The larger the sensitive area, the more computing power is  
required, and data will be processed more slowly.  
A smaller sensitive area means that data processing is faster.  
The sensitive area is shown in yellow hatching.  
In the default setting, the whole of the image captured by the  
camera is defined as the sensitive area. Any areas that consist  
of small squares can be defined as non-sensitive (or again as  
sensitive). There are four editing tools you can use for this pur-  
pose. You can also repeat this operation as often as you like to  
achieve a very precise definition of the sensitive area.  
BOSCH Security Systems  
1.0 | 2006.04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
34 en | Area settings  
IVMD | Configuration instructions  
You will find all of the commands in the context menu.  
Sensitive area  
Examples of areas that could be defined as non-sensitive:  
Railroad: Passing trains can trigger unwanted motion  
alarms.  
Public streets: Passers-by moving across a public space  
should not be detected – in order to save computing  
power and prevent unwanted false alarms.  
Neighboring properties.  
Areas in which moving objects are not anticipated.  
Sky: Birds or planes can trigger false alarms.  
Trees or bushes that move in the wind.  
1.0 | 2006.04  
BOSCH Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IVMD | Configuration instructions  
Area settings | en 35  
The following commands are available:  
Save and  
The settings are saved. You exit the Editor for  
the sensitive area.  
Exit Editor  
Undo  
The last action you carried out is undone.  
Set All  
The whole of the captured area is defined as  
the sensitive area.  
Clear All  
Tool  
The whole of the captured area is defined as  
non-sensitive.  
Selects an editing tool:  
Rubber Band:  
You can use the mouse to draw any size of  
square.  
Small Square, Medium Square, Large Square  
You can edit the sensitive area as with a draw-  
ing tool.  
NOTE!  
While you are drawing, hold down the SHIFT key to create non-  
sensitive areas.  
i
Drawing by itself without the SHIFT key marks out sensitive  
areas.  
BOSCH Security Systems  
1.0 | 2006.04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
36 en | Area settings  
IVMD | Configuration instructions  
4.6  
Statistics  
The statistics for a detector field help you to refine the filter cri-  
teria for objects. For example, you may see an accumulation of  
objects that have not triggered an alarm under the current filter  
criteria even though this might have been desirable.  
You can view the Statistics dialog separately for each detector  
field. To create the displayed statistics, start by opening the  
dialog. The longer the dialog is left open, the more data will be  
entered in the statistics.  
Green:  
Set of objects  
with no alarm  
Red:  
Set of objects  
with alarm  
Black:  
Filter area that  
allows alarm  
Gray:  
Filtered-out area;  
no alarm  
The statistics show three histograms:  
Area: accumulation of objects with a certain surface area.  
Speed: accumulation of objects moving at a certain speed.  
Direction: accumulation of objects moving in a certain  
direction.  
The black area in each histogram is the area that was defined in  
the Properties of Detector Field dialog for the particular filter  
1.0 | 2006.04  
BOSCH Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
IVMD | Configuration instructions  
Area settings | en 37  
(see page 28). Areas that are outside the defined limits are  
grayed.  
The lines indicate the number of objects for which the respec-  
tive value was detected. The higher the line, the more objects  
matched the particular criterion. The histograms distinguish  
between objects that trigger an alarm (red line) and those that  
do not (green line).  
NOTE!  
Click Reset to begin building statistics again.  
i
BOSCH Security Systems  
1.0 | 2006.04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
38 en | Display of Measurements  
IVMD | Configuration instructions  
5
Display of Measurements  
When you are working with the English software interface, mea-  
surements can be displayed according to the imperial system.  
1. Close the Configuration Manager.  
2. Click Start > My Computer.  
3. Right-click the window and select Properties from the  
popup menu.  
The window System Properties opens.  
4. Click the Advanced tab.  
5. Click Environment Variables.  
The respective window opens.  
6. Under User Variables click New.  
The respective dialog opens.  
7. Enter:  
Name of the variable: LANG  
Value of the variable: us  
8. Close all windows by clicking OK.  
9. Start the Configuration Manager.  
Measurements will be shown according to the imperial  
system.  
NOTE!  
Delete this user variable to return to the default display.  
This user variable is only valid for the current Windows login.  
You can create various Windows accounts, so that the display is  
pre-determined by the Windows-login.  
i
1.0 | 2006.04  
BOSCH Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
IVMD | Configuration instructions  
Contact and Service | en 39  
6
Contact and Service  
Contact address  
Bosch Sicherheitssysteme GmbH  
Robert-Koch-Straße 100  
85521 Ottobrunn  
Germany  
E-mail:  
Internet:  
BOSCH Security Systems  
1.0 | 2006.04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
40 en | Contact and Service  
IVMD | Configuration instructions  
Service and support  
If you have any questions about the programs from the VIDOS  
Pro Suite, you can find further information on the Internet at:  
Technical support is available from:  
Americas  
Bosch Security Systems  
130 Perinton Parkway  
Fairport, New York, 14450, USA  
Phone:  
Fax:  
+1 585 223 4060  
+1 585 223 9180  
E-mail:  
Internet:  
Europe, Middle East, Africa  
Bosch Security SystemsB.V.  
P.O. Box 8000  
25600 JB Eindhoven, The Netherlands  
Phone:  
Fax.  
+31 (0)40 27 83955  
+31 (0)40 27 86668  
E-mail:  
Internet:  
Asia-Pacific  
Bosch Security Systems Pte Ltd  
38C Jalan Pemimpin  
Singapore 577180  
Phone:  
Fax:  
+65 6319 3450  
+65 6319 3499  
E-mail:  
Internet:  
1.0 | 2006.04  
BOSCH Security Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IVMD | Configuration instructions  
| en 41  
Index  
Object outlines  
A
Analysis type 10  
Anchor point  
calibration 23  
displaying 19  
R
C
Calibration plane 23  
Contact address 39  
Cube  
Sensitive area  
displaying 19  
calibration 24  
Cube size 27  
D
T
Default settings 10  
Detector fields  
displaying 19  
Direction  
Tilt angle 25  
Tolerance angle 31  
Trigger 30  
displaying 19  
V
VCA 9  
F
Filters 29  
H
Height of camera position 26  
M
Meta data 10, 19  
N
Node  
detector field 18  
O
Object bounding box  
displaying 19  
Object direction filter 31  
Object filter 29  
Object markings 11  
BOSCH Security Systems  
1.0 | 2006.04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Bosch Sicherheitssysteme GmbH  
Robert-Koch-Straße 100  
85521 Ottobrunn  
Germany  
Telephone +49 (0) 89 6290-0  
Fax  
+49 (0) 89 6290-1020  
© Bosch Sicherheitssysteme GmbH, 2006  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Bel Canto Design Stereo Amplifier PHONO 1 User Manual
Black Box Log Splitter AC156A 8 User Manual
Black Decker Vacuum Cleaner WV1400 User Manual
Bolens Lawn Mower 191 761 User Manual
Briggs Stratton Air Conditioner 071015 User Manual
Briggs Stratton Pressure Washer 3500PSI User Manual
Bryant Furnace 315AAV User Manual
Bushnell Hunting Equipment 202205 User Manual
Campbell Hausfeld Log Splitter HM750099 User Manual
Chauvet Work Light 15090388 User Manual