A50-62313-00006
333XL/333XL-212/333/333-212
User Manual
en
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of contents
Online registration.............................................................................................................4
Footswitch........................................................................................................................7
Inside the BUGERA............................................................................................................7
Instructions for qualified service personnel only.....................................................................7
en
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Make sure that children cannot play unsuper-
vised with the unit or its packaging.
$
$
IMPORTANT NOTICE!
FAILURE TO OBSERVE THE FOLLOWING POINTS MAY RE-
SULT IN DAMAGE TO THE AMPLIFIER OR LOUDSPEAK-
ERS. DAMAGES CAUSED IN SUCH A WAY ARE NOT COV-
ERED BY WARRANTY.
Please ensure proper disposal of all packing
materials.
Ensure adequate air supply and to avoid overheating do
not place the unit near radiators etc.
Before you start, always make sure that your
$
Bugera Valve Amplifier is connected to a suit-
able loudspeaker. Observe the correct imped-
ance for your loudspeaker and use the appro-
priate output socket.
Please make sure that all devices are properly
$
grounded. For your own safety, never remove
or disable the ground conductors from the de-
vices or on the power cords. The unit must al-
ways be connected to the mains outlet with a
protective grounding connection.
Always use loudspeaker cables for connection
$
between the amplifier and the loudspeaker.
Never use other types of cable, like instru-
ment cable or microphone cable.
The tone quality may diminish within the
$
range of powerful radio broadcasting stations
and high-frequency sources. Increase the dis-
tance between the transmitter and the unit,
and use shielded cables for all connections.
Switching the amplifier on and off:
Before connecting the amplifier to a power out-
let, make sure that both POWER and STANDBY
switches are set to the OFF position.
$
Online registration
Please do remember to register your new BUGERA equip-
amps.com and kindly read the terms and conditions of
our warranty carefully.
Power on (mandatory):
Switch the POWER switch on—wait for 60 sec-
$
onds—then switch the STANDBY switch on.
Should your BUGERA product malfunction, our goal is
to have it repaired as quickly as possible. To arrange for
warranty service, please contact the retailer from whom
the equipment was purchased. Should your BUGERA
dealer not be located in your vicinity, you may directly
contact the BEHRINGER company nearest to you. This
contact information is included in the original equip-
ment packaging (Global Contact Information/European
Contact Information). Should your country not be list-
ed, please contact our exclusive distributor BEHRINGER
Singapore (BEHRINGER Holdings (Pte) Ltd., 1 Kim Seng
Promenade #08-08, Great World City West Tower, Sin-
gapore 237994, Tel.: +65 6845 1800, Fax: +65 6214
0275).
Power off (recommended):
Switch the STANDBY switch off—wait for 30
seconds—then switch the POWER switch off.
$
Note—after powering off we recommend that the ampli-
fier is allowed to cool down for ten minutes before any
attempt is made to move the amplifier. This reduces the
risk of mechanical damage to the sensitive valve ele-
ments.
ATTENTION! TO AVOID DAMAGE TO YOUR
AMP, NEVER USE THE BUGERA VALVE AM-
PLIFIER WITHOUT A LOUDSPEAKER CON-
NECTED!
!
Registering your purchase and equipment with us helps
us process your repair claims quicker and more efficient-
ly.
en
Thank you for your cooperation!
Introduction
Congratulations! By purchasing the BUGERA, you have CAUTION!
chosen a state-of-the-art valve amplifier.
Please note that high volume levels may cause
$
This 120-Watt full-valve amp offers you 3 full-fledged
channels with 3 tone controls, a separate switchable Ef-
fects Loop plus integrated Reverb and much more. This
way you’re in full control and can get down to the nitty-
gritty—your music! Discover the sound of the BUGERA
and be inspired by its versatility. Whatever style you
play, this monster amp gives you the full valve power
that you require.
permanent damage to your hearing and/or
your loudspeakers. Turn the MASTER control
to the left before switching on the unit. Be sure
to keep the volume at an appropriate level.
Before you get started
Your product was carefully packed at the factory to en-
sure safe transport. Nevertheless, if the box is damaged
inspect the unit immediately for signs of damage.
If the unit is damaged please do NOT return it
$
to us, but notify your dealer and the shipping
company immediately; otherwise, claims for
damage or replacement may not be granted.
Always use the original box to prevent dam-
age during storage or transport.
$
Introduction
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Control elements
Front panel of the BUGERA 333XL
12 The BASS controls of the LEAD and CRUNCH chan-
Front panel
nels adjust the lower frequency range (active shelv-
ing control for up to 15 dB boost/cut).
1
The POWER switch is used to turn the power of the
BUGERA amplifier on and off.
13 The GAIN control lets you determine the input lev-
el of the LEAD and CRUNCH channels (the CLEAN
channel doesn’t feature a GAIN control). Turn the
control to the right to increase the preamplifier’s
distortion and sustain.
2
The STANDBY switch allows you to place the amp
in STANDBY mode. This way the amp is idle, but
the operational temperature of the valves is main-
tained (POWER switch turned on). Flick the STAND-
BY switch to change to the active mode (the above
status light illuminates).
Please note that extremely high GAIN and
$
VOLUME settings in conjunction with high
MASTER settings can make the combo mod-
els vibrate mechanically. This may occur when
played at extremely high volume levels, which
is seldom done. Should this be the case, ad-
just the GAIN and VOLUME settings so that the
problem does not recur.
ATTENTION! TO AVOID DAMAGE TO YOUR
AMP, NEVER USE THE BUGERA VALVE AM-
PLIFIER WITHOUT A LOUDSPEAKER CON-
!
NECTED!
3
The MASTER control adjusts the volume level of
the BUGERA. First, bring the levels of the ampli-
fier’s three channels into line and only then specify
the overall level with the MASTER control. Turn the
control to the right to increase the volume; turn it
to the left to reduce the volume.
14 The XL switches of the LEAD and CRUNCH channels
change the amplifier’s response at low frequencies
(only 333XL and 333XL-212). It fattens up the tone
by providing more low-end.
15 The LEAD switch activates the LEAD channel (switch
4
The PRESENCE control modifies the amp’s damping
factor at high frequencies (only 333XL and 333XL-
212). This is used to fine-tune the high-frequency
range of the speaker cabinet.
glows red).
16 The CRUNCH switch activates the CRUNCH channel
(switch glows yellow).
en
17 The passive TREBLE control adjusts the upper fre-
5
6
7
The REVERB control determines the amount of the
built-in reverb effect.
quency range of the CLEAN channel.
18 The passive MID control adjusts the mid frequency
The REVERB switch activates the REVERB effect
(switch glows yellow).
range of the CLEAN channel.
19 The passive BASS control adjusts the lower fre-
The FX LOOP/BOOST switch activates the FX LOOP
and the BOOST function (switch glows green).
quency range of the CLEAN channel.
20 The CLEAN switch activates the CLEAN channel
You can also activate the FX LOOP with the
supplied footswitch. Refer to „Footswitch“ for
details.
$
(switch glows red).
You can activate the three channels with the
supplied footswitch. Refer to „Footswitch“ for
details.
$
8
The NOISE GATE control determines the effect the
NOISE GATE filter has on the LEAD and CRUNCH
channels (only 333XL and 333XL-212). The further
you turn the control to the right, the more noise
is reduced. At low GAIN settings, the NOISE GATE
shouldn’t be set too high or else the tones’ sustain
is affected.
21 The HIGH GAIN input (333 and 333-212: INPUT)
is 6 dB louder than the LOW GAIN input and is used
for most electric guitars.
22 The LOW GAIN input is used for instruments with
an extremely high output level which could distort
the HIGH GAIN input (only 333XL and 333XL-212).
9
The VOLUME controls adjust the volume levels of
all three amplifier channels.
The HIGH GAIN and LOW GAIN connectors
have identical sensitivity when used at the
same time (both with LOW GAIN sensitivity).
$
10 The TREBLE controls of the LEAD and CRUNCH
channels adjust the upper frequency range (active
shelving control for up to 15 dB boost/cut).
11 The MID controls of the LEAD and CRUNCH chan-
nels adjust the mid-frequency range (active peak/
notch control for up to 15 dB boost/cut).
Control elements
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Rear panel of the BUGERA 333
29 The IMPEDANCE switch lets you specify the loud-
Rear panel
CAUTION!
!
speaker impedance. Always apply the value that
is identical to the impedance of the used speaker
cabinet. When connecting two cabinets with the
same impedance, the switch should be set to half
the value of one of the cabinets. For example, two
16-Ohm cabinets would require an 8-Ohm setting,
while two 8-Ohm cabinets need to be set to the
minimum impedance of 4 Ohms. Please also read
„Wiring the BUGERA“.
Hot! Risk of injury! During use, the valves
get very hot and high surface temperatures
may be reached at the rear of this unit.
Avoid touching the controls and connectors
on the rear panel during use. To avoid acci-
dental contact with hot surfaces, place the
rear panel so that it faces a wall.
!
30 Both the paralleled LOUDSPEAKER outputs (¼"
mono jacks) are used to connect the speaker
cabinet(s). The minimum impedance is 4 Ohms. The
IMPEDANCE switch should always be set to match
the impedance of the used speaker cabinet.
23 The calibrated LEVEL control determines the signal
level sent to an external effects unit or any other
signal processor (0 – 10). Turn the control to the
right to increase the amount of signal information,
and turn it to the left to decrease the amount. It
makes sense to select a high setting in order to
get a possibly noise-free signal. The FX Send Level
and FX Return Level (26) controls should always be
set oppositely. For example, to reach a 0 dB work-
ing level when the FX Send Level is set low, the FX
Return Level (26) needs to be set high accordingly.
On the other hand, if you wish to boost the volume
level, turn both controls to a higher setting.
ATTENTION! TO AVOID DAMAGE TO YOUR
AMP, NEVER USE THE BUGERA VALVE AM-
PLIFIER WITHOUT A LOUDSPEAKER CON-
NECTED!
!
31 This is the LEVEL control that specifies the signal
level for the OUT (32) in order to adjust the level
of a second amplifier and loudspeaker system con-
nected over the OUT to the LOUDSPEAKER outputs
(30) of one or more connected speaker cabinets.
24 The SEND output is used to connect a shielded ¼"
mono jack cable to the input of an external effects
unit.
32 The OUT provides a preamp signal in order to feed
the signal to a second amplifier and loudspeaker
system, for example.
25 The RETURN input is used to connect a shielded
¼" mono jack cable to the output of an external
effects unit.
en
26 The calibrated LEVEL control determines the signal
level returned from an external effects unit or any
other signal processor (0 – 10). Turn the control
to the right to increase the amount of signal in-
formation, and turn it to the left to decrease the
amount. To achieve a possibly noise-free signal, set
the FX Send Level (23) relatively high and the FX
Return Level relatively low. A BOOST effect can be
achieved with this LEVEL control when the RETURN
input isn’t being used. Increase the volume level
with this control plus activate the FX LOOP with the
footswitch in order to make the guitar signal louder.
This function is great for highlighting solos.
*
33 WARNING: ONLY REPLACE THE FUSE WHEN THE
MAINS CABLE HAS BEEN DISCONNECTED! The
FUSE is found in the fuse holder. If the fuse is
blown, it needs to be replaced with a fuse of the
same kind by all means. Otherwise, the unit could
seriously be damaged, in which case the warranty
is void. If the fuse is blown repeatedly, you should
take the unit to a qualified service technician.
*
34 The IEC MAINS connector is used to connect the
mains cable that has the appropriate voltage rat-
ings for your country (included). At all times, make
the connections to the amplifier before plugging the
cable into a power outlet.
27 The 7-pin FOOTSW(itch) connector is provided
to connect to the supplied BUGERA FSB104 foot-
switch. Please be sure to connect the cables before
switching on the amplifier. Refer to „Footswitch“ for
details.
35 This is the SERIAL NUMBER of the amplifier.
28 The DAMPING switch lets you specify the damping
factor of the BUGERA (only 333 and 333-212). The
term „damping“ refers to a feature of the ampli-
fier that affects the signal’s fade-out phase. A high
damping factor (HIGH) makes the signal fade out
quicker than a low factor (LOW). Changes to the
damping factor automatically result in level altera-
tions which should be re-adjusted.
Control elements
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Inside the BUGERA 333
Footswitch
Inside the BUGERA
DANGER!
*
High voltage! Risk of death!
High voltages of up to 500 V DC may be
present inside the casing for long periods
after being disconnected from the mains.
To avoid lethal electric shock, do not open
the casing. There are no user-serviceable
components inside. Refer all maintenance
to qualified service personnel. Remove the
mains cable when the unit is not in use.
The parts inside the amplifier operate at
high voltages and high temperatures. To
avoid damage and injury that results from
fire or electric shock, do not drop or spill
anything into the unit’s casing.
*
Footswitch BUGERA FSB104
Instructions for qualified service
personnel only
Remove the backside of the amplifier’s casing to get to
en
36 The 7-pin DIN connector is provided to connect
the footswitch cable (included). Then, the cable is
connected to the FOOTSW(itch) connector of the
BUGERA amplifier. Be sure to make a connection
before switching on the amplifier.
the valves and the control elements.
41 These are the sockets for the 12AX7A/B/C pre-
37 The CLEAN switch activates the CLEAN channel. Its
amp valves.
LED illuminates when the channel is active.
42 These are the sockets for the 6L6 and EL34 power
amp valves. Please take care that the BIAS SELECT-
switch (43) is set correctly. The models 333 and
333-212 are supplied with 6L6GC power amp valves
when it leaves the factory. The models 333XL and
333XL-212 incorporate EL34 power amp valves.
38 The CRUNCH switch activates the CRUNCH chan-
nel. Its LED illuminates when the channel is active.
39 The LEAD switch activates the LEAD channel. Its
LED illuminates when the channel is active.
40 The FX LOOP switch activates the FX LOOP and the
BOOST function. Its LED illuminates when the FX
LOOP is active.
43 The BIAS SELECT switch allows the amplifier to
optimally adapt to the used valves (6L6 or EL34).
*
44 The BIAS TEST connector lets you connect a volt-
meter in order to measure the power amp valves
(bias adjustment). Make sure that the voltmeter is
set to direct current (DC).
45 The BIAS ADJUST control is used to make the bi-
as-adjustment.
Replacing the power amp valves also requires
$
bias adjustment. You should always use sets
of four matched valves. The valves of the
BUGERA Series are ideal for this purpose.
Control elements
7
Download from Www.Somanuals.com. All Manuals Search And Download.
CAUTION: WE HIGHLY RECOMMEND THAT
BIAS ADJUSTMENTS BE CARRIED OUT BY
QUALIFIED PERSONNEL!
!
Wiring the BUGERA
CAUTION!
!
Hot! Risk of injury! During use, the valves
will get very hot and high surface temper-
atures may be reached at the rear of this
unit. To avoid burning yourself, make all
connections while the unit is still cold.
ATTENTION! TO AVOID DAMAGE TO YOUR
AMP, NEVER USE THE BUGERA VALVE AM-
PLIFIER WITHOUT A LOUDSPEAKER CON-
NECTED!
!
The BUGERA amplifier has two paralleled LOUDSPEAKER
outputs which are used to connect one or two speaker
cabinets.
If you only connect one speaker cabinet, be sure that the
IMPEDANCE switch is set to match the impedance of the
connected cabinet.
BUGERA head with a speaker cabinet
If you want to connect two speaker cabinets, both cabi-
nets should have to the same impedance. Be sure to
have set the IMPEDANCE switch correctly. In this case,
set it to half the value of one of the cabinets. When us-
ing two
16-Ohm cabinets, the switch therefore needs to be set
to 8 Ohms; and with two 8-Ohm cabinets, set it to the
minimum impedance of 4 Ohms.
CAUTION: The loudspeakers in the combos are connect-
ed in series. This results in an impedance of 16 Ohms.
en
Impedances
Wiring the BUGERA
8
Download from Www.Somanuals.com. All Manuals Search And Download.
The following figure shows a setup of the 333XL-212 to-
gether with an external effects unit connected over the
FX LOOP. And the LINE OUT is connected to the line input
of a mixer in order to send the signal to a recording de-
vice. The LEVEL control of the LINE OUT lets you adjust
the output level of the BUGERA to the input sensitivity of
the mixer. In addition, the speaker signal of the BUGERA
is picked up by a microphone and is fed to the micro-
phone input of the mixer. This way you get a second
guitar signal which then can be amplified by a PA system
and/or can be recorded as well.
Audio connections
The inputs and outputs of the BUGERA amplifier use
mono jack connectors.
¼" mono jack connector
en
Live setup with a BUGERA combo
Audio connections
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
PREAMP SECTION
Valves
Type
1 x 12AX7A
1 x 12AX7B
2 x 12AX7C
Preamp high-gain input
Impedance
470 kΩ
Clean channel
Nominal input level
Min. input level
Max. input level
Crunch channel
Nominal input level
Min. input level
-20 dBV
-30 dBV
0 dBV
-80 dBV
-90 dBV
Lead channel
Nominal input level
Min. input level
-80 dBV
-90 dBV
Preamp low-gain input (only 333XL and 333XL-212)
Impedance
44 kΩ
All levels attenuated by
Effects send
+6 dB
Impedance
47 kΩ or higher
Min. output level
Max. output level
Effects return
Impedance
Min. input sensitivity
Max. input sensitivity
Line output
-10 dBV, 300 mV RMS
0 dBV, 1 V RMS
470 kΩ
-10 dBV
0 dBV
Impedance
47 kΩ or higher
Adjustable output level
±20 dBV
POWER AMPLIFIER SECTION
Valves
Type
4 x 6L6GC (333 and 333-212)
4 x EL34 (333XL and 333XL-212)
Output power
Peak power
120 W / 16, 8, 4 Ω
Loudspeaker connectors
Type
¼" mono jack connectors, unbalanced
Load impedance
4 Ω / 8 Ω / 16 Ω switchable
Internal loudspeakers (only 333XL-212 and 333-212)
Type
Impedance
2 x 12" BUGERA, 12G70J8
8 Ω
en
Continuous power
Total impedance
70 W (IEC)
16 Ω (series connection)
POWER SUPPLY
U.S./Canada
China
120 V~, 60 Hz
220 V~, 50 Hz
Korea
220 V~, 60 Hz
Europe/U.K./Australia
Japan
230 V~, 50 Hz
100 V~, 50/60 Hz
General export model
Power consumption
Fuse
120/230 V~, 50/60 Hz
Max. 350 W
T 3.15 A H 250 V (100 – 120 V~, 50/60 Hz)
T 1.6 A H 250 V (220 – 230 V~, 50/60 Hz)
Standard IEC receptacle
Mains connection
DIMENSIONS/WEIGHT
333
Dimensions (H x W x D)
Weight
Approx. 9 25/32" x 27" x 9 11/16" (249 mm x 687.3 mm x 246 mm)
Approx. 47 lbs (21.5 kg)
333-212
Dimensions (H x W x D)
Weight
Approx. 20 13/32" x 27" x 9 3/4" (518.46 mm x 687.3 mm x 247.65 mm)
Approx. 63 lbs (28.5 kg)
333XL
Dimensions (H x W x D)
Weight
Approx. 9 25/32" x 27" x 9 11/16" (249 mm x 687.3 mm x 246 mm)
Approx. 47 lbs (21.5 kg)
333XL-212
Dimensions (H x W x D)
Weight
Approx. 20 13/32" x 27" x 9 3/4" (518.46 mm x 687.3 mm x 247.65 mm)
Approx. 63 lbs (28.5 kg)
We are constantly striving to maintain the highest professional standards. As a result of these efforts, modifications may be made from time to time to
existing products without prior notice. Specifications and appearance may differ from those listed or illustrated.
Specifications
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Limited warranty
SPECIAL NOTE: NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL ONLY.
§ 1 Other warranty rights and national law
1. This limited warranty does not exclude or limit the buyer’s statutory rights provided by national law, in particular, any such rights against the seller that
arise from a legally effective purchase contract.
2. The limited warranty regulations mentioned herein are applicable unless they constitute an infringement of national warranty law.
§ 2 Online registration
and conditions of our limited warranty carefully. Registering your purchase and equipment with us helps us process your repair claims quicker and more
efficiently. Thank you for your cooperation!
§ 3 Limited Warranty
1. BEHRINGER warrants the mechanical and electronic components of this product to be free of defects in material and workmanship if used under normal
operating conditions for a period of one (1) year** from the original date of purchase.
2. BEHRINGER warrants valves (tubes) and meters contained in the product to be free of defects in material and workmanship if used under normal operat-
ing conditions for a period of 90 days from the original date of purchase.
3. This limited warranty is subject to the conditions, exclusions and limitations hereinafter set forth.
4. If the product shows any defects within the specified warranty period that are not excluded from this warranty as described under § 5, BEHRINGER will,
at its discretion, either replace the product by providing a new or reconditioned product or repair the product using suitable new or reconditioned parts.
In the case that other parts are used which constitute an improvement, BEHRINGER may, at its discretion, charge the customer for the additional cost
of these parts. In case BEHRINGER decides to replace the entire product, this warranty shall apply to the replacement product for the remaining initial
warranty period, i.e., one year** from the date of purchase of the initial product.
5. If the warranty claim proves to be justified, the product will be returned to the user freight prepaid.
6. Warranty claims other than those indicated above are expressly excluded.
PLEASE RETAIN YOUR SALES RECEIPT, AS IT IS YOUR PROOF OF PURCHASE COVERING YOUR LIMITED WARRANTY. THIS LIMITED WARRANTY IS VOID
WITHOUT SUCH PROOF OF PURCHASE.
§ 4 Return authorization number
1. To obtain warranty service, the buyer (or his authorized dealer) must call BEHRINGER as exclusive distributor of BUGERA products (see enclosed list)
during normal business hours BEFORE returning the product. All inquiries must be accompanied by a description of the problem. The buyer or his au-
thorized dealer will receive a return authorization number
2. Subsequently, the product must be returned in its original shipping carton, together with the return authorization number. The return shipment address
will be indicated by BEHRINGER.
3. Shipments without freight prepaid will not be accepted.
§ 5 Warranty regulations
1. Warranty services will be furnished only if the product is accompanied by a copy of the original retail dealer’s invoice.
2. If the product needs to be modified or adapted in order to comply with applicable technical or safety standards on a national or local level, in any country
which is not the country for which the product was originally developed and manufactured, this modification/adaptation shall not be considered a defect
in materials or workmanship. This limited warranty does not cover any such modification/adaptation, irrespective of whether it was carried out properly
or not. Under the terms of this limited warranty, BEHRINGER shall not be held responsible for any cost resulting from such a modification/adaptation.
3. Free inspections and maintenance/repair work are expressly excluded from this limited warranty, in particular, if caused by improper handling of the
product by the user. This also applies to defects caused by normal wear and tear, in particular, of faders, crossfaders, potentiometers, keys/buttons,
tubes, guitar strings, illuminants and similar parts.
4. Damage/defects caused by the following conditions are not covered by this limited warranty:
>
>
improper handling, neglect or failure to operate the unit in compliance with the instructions given in BEHRINGER user or service manuals
connection or operation of the unit in any way that does not comply with the technical or safety regulations applicable in the country where the
product is used.
>
damage/defects caused by force majeure or any other condition that is beyond the control of BEHRINGER.
en
5. Any repair or service performed by any person or entity other than a BEHRINGER authorized service center is not covered by this limited warranty.
6. Any repair or opening of the unit carried out by unauthorized personnel (user included) will void this limited warranty.
7. Any exchange of the tubes/valves and associated biasing by any person or entity other than a BEHRINGER authorized service centre will void this limited
warranty.
8. If an inspection of the product by BEHRINGER shows that the defect in question is not covered by this limited warranty, the inspection costs are payable
by the customer.
9. Products which do not meet the terms of this limited warranty will be repaired exclusively at the buyer’s expense. BEHRINGER will inform the buyer of
any such circumstance. If the buyer fails to submit a written repair order within 6 weeks after notification, BEHRINGER will return the unit. Costs for
freight and packing will be invoiced separately C.O.D. When the buyer has sent in a written repair order, such costs will also be invoiced separately.
§ 6 Warranty transferability
This limited warranty is extended exclusively to the original buyer (customer of retail dealer) and is not transferable to anyone who may subsequently
purchase this product.
§ 7 Claim for damages
Failure of BEHRINGER to provide proper warranty service shall not entitle the buyer to claim (consequential) damages. In no event shall the liability of
BEHRINGER exceed the invoiced value of the product.
§ 8 U.S. Customers only
THE FOREGOING CONSTITUTES THE ONLY WARRANTY MADE BY BEHRINGER WITH RESPECT TO THE PRODUCT AND IS MADE EXPRESSLY IN LIEU OF ALL
OTHER WARRANTIES EXPRESS OR IMPLIED. Any implied warranties, including without limitation, any implied warranties of merchantability or fitness for
any particular purpose, imposed under state law are limited to the duration of this limited warranty. Some states do not allow limitations on how long an
implied warranty lasts, so the above limitations may not be applicable to you.
BEHRINGER ASSUMES NO LIABILITY FOR PROPERTY DAMAGE RESULTING FROM FAILURE OF THIS PRODUCT NOR ANY LOSS OF INCOME, SATISFACTION
OR DAMAGES ARISING FROM THE LOSS OF USE OF SAME DUE TO DEFECTS OR AVAILABILITY OF SAME DURING SERVICE.
**Customers in the European Union please contact BEHRINGER Germany Support for further details.
Technical specifications and appearance are subject to change without notice. The information contained herein is correct at the time of printing. All trade-
marks (except BUGERA, the BUGERA logo, and THE SOUL OF VALVES) mentioned belong to their respective owners, and such use neither constitutes a
claim of the trademarks by RED CHIP COMPANY LTD nor affiliation of the trademark owners with RED CHIP COMPANY LTD. RED CHIP COMPANY LTD accepts
no liability for any loss which may be suffered by any person who relies either wholly or in part upon any description, photograph or statement contained
herein. Colors and specifications may vary slightly from product. Our Products are sold through authorized dealers only. This manual is copyrighted. No part
of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording of any kind,
for any purpose, without the express written permission of RED CHIP COMPANY LTD. BUGERA-products are distributed exclusively by the BEHRINGER Group
of companies globally, and specifically by BEHRINGER International GmbH in the European Union. ALL RIGHTS RESERVED. (c) 2008 RED CHIP COMPANY
LTD. Trident Chambers, Wickhams Cay, P.O. Box 146, Road Town, Tortola, British Virgin Islands.
Limited warranty
11
Download from Www.Somanuals.com. All Manuals Search And Download.
|