		 Installation   
					Instructions   
					2175.503   
					COLONY SOFT   
					Single Control Lavatory Faucet   
					with Speed Connect™ Drain   
					Congratulations on purchasing your American Standard faucet with the   
					Speed Connect drain, a feature found only on American Standard faucets.   
					Speed Connect Drain*   
					• 1/3 of the parts, installs in 1/3 of the time   
					• No tools needed   
					Certified to comply with ANSI A112.18.1   
					M968882 Rev. 1.3   
					• Never needs adjustment   
					• Guaranteed to seal properly the first time, every time.   
					*Your new American Standard faucet is designed to work only with the Speed Connect drain.   
					To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.   
					Recommended tools   
					Tubing Cutter   
					Screwdriver   
					Channel Locks   
					Adjustable Wrench   
					Plumbers' Putty or Caulking   
					Turn off hot and cold water   
					supplies before beginning.   
					1 
					INSTALL FAUCET   
					CAUTION   
					Apply a bead of putty along the edge of the underside of the FAUCET (1).   
					Insert FAUCET (1) and CABLE CONNECTOR (2) through center hole   
					of mounting surface. Fig. A.   
					Fig. A.   
					From under side of mounting surface thread the two MOUNTING   
					NUTS (2) onto FAUCET SHANKS (4). Fig. B.   
					1 
					Center FAUCET (1) and hand tighten MOUNTING NUTS (3) to   
					secure FAUCET (1).   
					PUTTY   
					3 
					3 
					(HAND TIGHTEN)   
					2 
					Fig. B.   
					4 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					1 
				ATTACH CABLE CONNECTOR   
					6 
					7 
					Fig. A.   
					Fig. B.   
					Thread CABLE CONNECTOR (1) clockwise   
					onto DRAIN BODY CONNECTION (2) and   
					hand tighten. Fig. A.   
					1 
					Your new POP-UP DRAIN installation is   
					now complete. Fig. B.   
					Note: Tailpeice on pop-up drain is 1-1/4” O.D.   
					Fig. B.   
					1-1/4” O.D.   
					2 
					CHECK OPERATION OF POP-UP   
					Operate LIFT KNOB (1) to verify that STOPPER (2) opens and   
					closes.   
					1 
					Note: If STOPPER (2) does not open and close properly then refer   
					to the “troubleshooting section” of these instructions.   
					2 
					MAKE WATER SUPPLY AND WASTE CONNECTIONS   
					8 
					NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS NOT INCLUDED   
					AND MUST BE PURCHASED SEPARATELY.   
					Connect water supply to INLET SHANKS (1) with 1/2" IPS   
					FLEXIBLE SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3).   
					Use adjustable wrench to tighten connections. Do not over   
					tighten. Be careful not to kink copper supply when bending.   
					Use tubing cutter to cut to proper length.   
					3/8 O.D.   
					BULL-NOSE   
					RISERS   
					3 
					Connect HOT water supply to inlet of left SHANK and COLD   
					water supply to right SHANK using sealant, appropriate   
					connectors, and COUPLING NUTS.   
					COUPLING   
					NUT WITH   
					FAUCET   
					1 
					Connect 1-1/4” O.D. TAILPIECE (4) on POP-UP   
					DRAIN to “p” trap.   
					COUPLING   
					NUT ON FLEX   
					SUPPLIES   
					2 
					COMPRESSION   
					NUT   
					FLEXIBLE   
					SUPPLIES   
					4 
					FERRULE   
					COLD   
					“P” TRAP   
					3/8 COMPRESSION   
					CONNECTION   
					HOT   
					M968882 Rev. 1.3   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				TEST INSTALLED FITTING   
					9 
					5 
					1 
					With HANDLE (1) in OFF position, turn on WATER   
					SUPPLIES (2) and check all connections for leaks.   
					Ensure that AERATOR (3) is tightened completely.   
					Operate HANDLE (1) to to alow water flow.   
					3 
					CHECK DRAIN CONNECTIONS   
					10   
					4 
					Operate POP-UP KNOB (5) and fill Sink with water. Check   
					that DRAIN STOPPER (4) makes a good seal and retains   
					water in Sink. If STOPPER (4) does not seal properly, please   
					refer to “Troubleshooting Guide” in these instructions.   
					Release POP-UP KNOB (5) down and check all drain   
					connections and "P" trap for leaks.   
					Tighten if necessary.   
					WASTE   
					OUTLET   
					2 
					“P” TRAP   
					2 
					SERVICE   
					11   
					1 
					2 
					4 
					If Faucet Drips Proceed As Follows:   
					Turn VALVE in OFF position.   
					If faucet drips, operate handle several times from "off" to "on".   
					Do not apply excessive force.   
					Clogged CARTRIDGE INLETS may cause reduced flow in "full on" hot   
					or cold. To clean inlets, first turn off water supply, then:   
					Remove HANDLE (1), CAP (2) and CARTRIDGE (3).   
					3 
					Clean CARTRIDGE INLETS and MANIFOLD.   
					MANIFOLD   
					CARTRIDGE INLETS   
					Reassemble CARTRIDGE (3), alternately tightening SCREWS (4).   
					Replace CAP (2) and HANDLE (1). Check flow.   
					CARE INSTRUCTIONS:   
					12   
					DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.   
					DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A   
					CLOTH WITH A COARSE SURFACE.   
					M968882 Rev. 1.3   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					4 
				Speed Connect™ Drain   
					Troubleshooting Guide   
					If sink does not hold water even though Stopper is in the “down” position:   
					• Follow CABLE ADJUSTMENT PROCEDURE.   
					If Stopper does not raise up fully or sink drains too slowly:   
					• Follow CABLE ADJUSTMENT PROCEDURE.   
					If you need to remove the Stopper:   
					• Follow STOPPER REMOVAL PROCEDURE.   
					If you would like the ability to remove your Stopper simply by lifting it out of the drain:   
					• Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.   
					CABLE ADJUSTMENT PROCEDURE   
					Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.   
					Look at the area on the Drain Body where the Cable was attached and locate the component labeled as   
					“Cam” in the illustration. Fig. B.   
					Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the   
					Stopper should be in the UP position. Fig. B, C.   
					Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.   
					Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the   
					Drain Body Connection (2) and hand-tighten. Fig. A.   
					Fig. A.   
					Fig. B. Fig. C.   
					CAM   
					DOWN   
					1 
					1 
					RE-ATTACH   
					STOPPER   
					CAM CAP   
					DISCONNECT   
					2 
					STOPPER REMOVAL PROCEDURE   
					Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.   
					Look at the area on the Drain Body where the Cable was attached and locate the component labeled   
					as “Cam” and “Cam Cap” in the illustration. Fig. B.   
					Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.   
					Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.   
					The Stopper can now be removed by lifting it out of the Drain. Fig. F.   
					Fig. F.   
					Fig. D.   
					F 
					REMOVE   
					CAM   
					REMOVE   
					CAM CAP   
					M968882 Rev. 1.3   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					5 
				STOPPER INSTALLATION PROCEDURE   
					The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be   
					removed) or “Unlock” Mode (Stopper is removable).   
					Locked Mode:   
					Look at the Plastic Loop at the bottom of the Stopper and notice   
					that the Loop is on one side of the Stopper. Fig. G.   
					Fig. G.   
					To install the stopper in “Locked” mode, insert the Stopper into   
					the Drain so that the Plastic Loop is facing toward the rear of the   
					Sink and the American Standard logo is facing front. Rotate   
					Stopper slightly if necessary so that the Stopper slides all the   
					way down.Fig. G.   
					LOGO   
					Re-install the Cam into the Drain, rotating the Cam if necessary   
					to make sure it is fully inserted. Fig. J.   
					LOOP TOWARD   
					REAR OF SINK   
					Re-install the Cam Cap, making sure the guide teeth are facing   
					outward. If the Cam Cap does not “snap” into place, then rotate   
					the Cam to make sure it is fully inserted. Fig. K.   
					DRAIN   
					Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in   
					Troubling Shooting Guide to complete installation. Stopper will be   
					in “Locked” mode and not be removable.   
					locked Mode   
					Unlocked Mode:   
					Look at the Plastic Loop at the bottom of the Stopper and notice   
					that the Loop is on one side of the Stopper. Fig. H.   
					Fig. H.   
					To install the stopper in “Unlocked” mode, insert the Stopper into   
					the Drain so that the Plastic Loop is facing toward the front of the   
					Sink and the American Standard logo is facing rear. Rotate Stopper   
					slightly if necessary so that the Stopper slides all the way down.   
					Fig. H.   
					LOGO   
					Re-install the Cam into the Drain, rotating the Cam if necessary   
					to make sure it is fully inserted. Fig. J.   
					180˚   
					LOOP TOWARD   
					FRONT OF SINK   
					Re-install the Cam Cap, making sure the guide teeth are facing   
					outward. If the Cam Cap does not “snap” into place, then rotate   
					the Cam to make sure it is fully inserted. Fig. K.   
					DRAIN   
					Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in   
					“Troublingshooting Guide” to complete installation. Stopper will be   
					in “Unlocked” mode and removable.   
					Unlocked Mode   
					Fig. J.   
					Fig. K.   
					CAM   
					INSTALL CAM   
					INSTALL   
					CAM CAP   
					M968882 Rev. 1.3   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					6 
				 |