AT-IX5-28GPX
Gigabit Ethernet Switch
25
SFP+ S1/27
CONSOLE
26
S2/28
1000 LINK
ACT
10/100 LINK
ACT
FDX
HDX
COL
2661
Installation Guide
C613-04067-00 REV B
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical Safety and Emissions Standards
This product meets the following standards.
U.S. Federal Communications Commission
Radiated Energy
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15
of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate
this equipment.
Industry Canada
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
RFI Emissions: FCC Class A, EN55022 Class A, EN61000-3-2, EN61000-3-3, VCCI Class A,
C-TICK, CE
Warning: In a domestic environment this product may cause radio interference in
which case the user may be required to take adequate measures.
EMC (Immunity): EN55024
Electrical Safety: EN60950-1 (UL-EU), UL 60950-1 (CULUS
)
Laser Safety EN60825
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Translated Safety Statements
Important: Safety statements that have the ꢀ symbol are translated into multiple languages in the
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Preface ................................................................................................................................................................................11
Document Conventions ........................................................................................................................................................12
Contacting Allied Telesis ......................................................................................................................................................13
Chapter 1: Overview ..........................................................................................................................................................15
Features ...............................................................................................................................................................................16
10/100/1000 Mbps Twisted Pair Ports ..........................................................................................................................16
Power Over Ethernet.....................................................................................................................................................16
Power Supply Modules..................................................................................................................................................17
Stacking Slots................................................................................................................................................................17
LEDs..............................................................................................................................................................................17
Installation Options........................................................................................................................................................17
MAC Address Table ......................................................................................................................................................17
Management Software and Interfaces ..........................................................................................................................18
Management Methods...................................................................................................................................................18
Front and Rear Panels .........................................................................................................................................................19
Management Panel ..............................................................................................................................................................20
10/100/1000Base-T Twisted Pair Ports................................................................................................................................21
Speed............................................................................................................................................................................21
Duplex Mode .................................................................................................................................................................21
Wiring Configuration......................................................................................................................................................21
Maximum Distance........................................................................................................................................................22
Cable Requirements......................................................................................................................................................22
Port Pinouts...................................................................................................................................................................22
Power Over Ethernet............................................................................................................................................................23
PoE Standards ..............................................................................................................................................................23
Powered Device Classes ..............................................................................................................................................24
Cable Requirements......................................................................................................................................................24
Power Budget................................................................................................................................................................25
Port Prioritization...........................................................................................................................................................26
Wiring Implementation...................................................................................................................................................27
SFP+ Slots............................................................................................................................................................................28
Stacking SFP+ Slots.............................................................................................................................................................29
eco-friendly Button................................................................................................................................................................30
LEDs.....................................................................................................................................................................................31
LEDs for the Twisted Pair Ports ....................................................................................................................................31
LEDs for the SFP+ Slots ...............................................................................................................................................32
LEDs for the Stacking Slots...........................................................................................................................................33
Switch ID LED ...............................................................................................................................................................34
USB Port...............................................................................................................................................................................36
Console Port.........................................................................................................................................................................37
Power Supplies.....................................................................................................................................................................38
Chapter 2: Virtual Chassis Stacking ................................................................................................................................39
Overview...............................................................................................................................................................................40
Stacking Slots.......................................................................................................................................................................41
Stacking Transceivers ..........................................................................................................................................................42
Stacking Port Topologies......................................................................................................................................................44
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Chapter 3: Beginning the Installation ..............................................................................................................................51
Reviewing Safety Precautions..............................................................................................................................................52
Choosing a Site for the Switches..........................................................................................................................................56
Planning a Stack...................................................................................................................................................................57
Chapter 4: Installing the Switch and its Power Supplies ...............................................................................................61
Installing Power Supply Modules..........................................................................................................................................63
Installing the Switches on a Table or Desktop......................................................................................................................66
Installing the Switch in an Equipment Rack..........................................................................................................................67
Chapter 5: Configuring the Switch for Stand-alone Operations ...................................................................................77
Disabling VCStack.........................................................................................................................................................78
Chapter 6: Verifying the Status of VCStack and Activating VCStack ...........................................................................85
Activating the VCStack Feature............................................................................................................................................87
Activating VCStack........................................................................................................................................................87
Chapter 7: Cabling the Stacking Ports ............................................................................................................................91
Chapter 8: Powering On the Stack .................................................................................................................................101
Powering On the Switches Individually...............................................................................................................................102
Verifying the Stack..............................................................................................................................................................106
Chapter 9: Cabling the Networking Ports ......................................................................................................................109
Installing SFP and SFP+ Transceivers...............................................................................................................................112
Chapter 10: Troubleshooting ..........................................................................................................................................117
Appendix A: Technical Specifications ...........................................................................................................................123
Certifications.......................................................................................................................................................................124
RJ-45 Twisted Pair Port Pinouts.........................................................................................................................................125
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Figures
Figure 1: Front Panel of the AT-IX5-28GPX Switch .............................................................................................................19
Figure 2: Back Panel of the Switch.......................................................................................................................................19
Figure 3: AT-IX5-28GPX Management Panel ......................................................................................................................20
Figure 4: LEDs for the 10/100/1000Base-T Ports.................................................................................................................31
Figure 5: SFP+ Slot LEDs ....................................................................................................................................................32
Figure 6: Switch ID LED .......................................................................................................................................................34
Figure 7: Switch ID LED .......................................................................................................................................................34
Figure 8: Switch ID LEDs in the Low Power Mode...............................................................................................................35
Figure 9: AT-PWR800 Power Supply...................................................................................................................................38
Figure 10: Stacking Transceivers .........................................................................................................................................42
Figure 11: Stack of Two Switches in the Linear Topology....................................................................................................44
Figure 12: Stack of Four Switches in the Linear Topology ...................................................................................................45
Figure 13: Stack of Two Switches in the Ring Topology ......................................................................................................46
Figure 14: Stack of Four Switches in the Ring Topology......................................................................................................47
Figure 15: PORT Parameter in the Command Line Interface...............................................................................................50
Figure 16: Components of the switch ...................................................................................................................................59
Figure 17: Power Cord Retaining Clip ..................................................................................................................................62
Figure 18: Inserting the Retaining Clip into the Retaining Bracket .......................................................................................62
Figure 19: Removing the rear panel .....................................................................................................................................63
Figure 20: Installing the AT-PWR800 Power Supply Module ...............................................................................................64
Figure 21: Securing the AT-PWR800 Power Supply Module ...............................................................................................65
Figure 22: Installing the Blank Panel on the Power Supply Slot...........................................................................................65
Figure 23: Turning the Switch Upside Down ........................................................................................................................67
Figure 24: Removing the Rubber Feet .................................................................................................................................67
Figure 25: Attaching the Equipment Rack Brackets .............................................................................................................68
Figure 26: Mounting the Switch Horizontally in an Equipment Rack ....................................................................................69
Figure 27: Mounting the Switch Vertically in an Equipment Rack ........................................................................................69
Figure 28: Power Cord Retaining Clip in the Up Position.....................................................................................................70
Figure 29: Connecting the AC Power Cord ..........................................................................................................................70
Figure 30: Connecting the Management Cable to the Console Port ....................................................................................72
Figure 31: Switch Initialization Messages.............................................................................................................................74
Figure 32: Switch Initialization Messages (Continued).........................................................................................................74
Figure 33: Switch Initialization Messages (Continued).........................................................................................................75
Figure 34: User Exec Mode Prompt .....................................................................................................................................78
Figure 35: SHOW STACK Command...................................................................................................................................79
Figure 36: Moving to the Global Configuration Mode ...........................................................................................................79
Figure 37: Confirmation Prompt for the NO STACK ENABLE Command ............................................................................80
Figure 38: Returning to the Privileged Exec Mode...............................................................................................................80
Figure 39: Saving the Changes with the WRITE Command.................................................................................................80
Figure 40: Status of a Stacking Slot When VCStack is Disabled .........................................................................................81
Figure 41: Status of a Stacking Slot When VCStack is Enabled ..........................................................................................82
Figure 42: PORT Parameter in the Command Line Interface...............................................................................................83
Figure 43: User Exec Mode Prompt .....................................................................................................................................87
Figure 44: Moving to the Privileged Exec Mode with the ENABLE Command.....................................................................87
Figure 45: Moving to the Global Configuration Mode with the CONFIGURE TERMINAL Command ..................................88
Figure 46: Activating VCStack with the STACK ENABLE Command...................................................................................88
Figure 47: Returning to the Privileged Exec Mode with the EXIT Command .......................................................................88
Figure 48: Saving the Change with the WRITE Command ..................................................................................................88
Figure 49: Rebooting the Switch with the REBOOT Command ...........................................................................................89
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Figures
Figure 51: Removing the Dust Cover from the AT-StackXS/1.0 Transceiver.......................................................................93
Figure 59: Connecting the Fiber Optic Cable to the Stacking Transceiver.........................................................................100
Figure 60: SHOW STACK Command.................................................................................................................................106
Figure 63: Saving the Priority Values with the WRITE Command......................................................................................108
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Tables
Table 1: IEEE Powered Device Classes ..............................................................................................................................24
Table 2: Twisted Pair Cable Requirements for the 10/100Base-TX Ports at 10 or 100Mbps ..............................................24
Table 3: Twisted Pair Cable Requirements for the 10/100/1000Base-T Ports at 1000Mbps ..............................................25
Table 4: LEDs on the 10/100/1000Base-T Ports .................................................................................................................31
Table 5: SFP+ Slot LEDs .....................................................................................................................................................33
Table 6: Stacking Slot LEDs ................................................................................................................................................33
Table 7: Stacking Transceivers ...........................................................................................................................................42
Table 8: Operating Distances of the AT-StackOP/0.3 Transceiver .....................................................................................58
Table 11: Power Specifications .........................................................................................................................................124
Table 15: RJ-45 Style Serial Console Port Pin Signals .....................................................................................................127
Table 16: Fiber Optic Port Specifications for the AT-StackOP/0.3 Module .......................................................................128
Table 17: Fiber Optic Port Specifications for the AT-StackOP/9.0 Transceiver ................................................................129
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Tables
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Preface
This guide contains the installation instructions for the AT-IX5-28GPX
Gigabit Ethernet switch. This preface contains the following sections:
Note
You can install AT-IX5-28GPX switches as stand-alone devices or in
a stack configuration with Virtual Chassis Stacking (VCStack™).
This guide explains both options.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Preface
Document Conventions
This document uses the following conventions:
Note
Notes provide additional information.
Caution
Cautions inform you that performing or omitting a specific action
may result in equipment damage or loss of data.
Warning
Warnings inform you that performing or omitting a specific action
may result in bodily injury.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
Contacting Allied Telesis
If you need assistance with this product, you may contact Allied Telesis
technical support by going to the Support & Services section of the Allied
the following services on this page:
24/7 Online Support — Enter our interactive support center to
search for answers to your product questions in our knowledge
database, to check support tickets, to learn about RMAs, and to
contact Allied Telesis technical experts.
USA and EMEA phone support — Select the phone number that
best fits your location and customer type.
Hardware warranty information — Learn about Allied Telesis
warranties and register your product online.
Replacement Services — Submit a Return Merchandise
Authorization (RMA) request via our interactive support center.
Documentation — View the most recent installation and user
guides, software release notes, white papers, and data sheets for
your products.
Software Downloads — Download the latest software releases for
your managed products.
For sales or corporate information, go to www.alliedtelesis.com/
purchase and select your region.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Preface
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1
Overview
This chapter contains the following sections:
Note
You can install AT-IX5-28GPX switches as stand-alone devices or in
a stack configuration with Virtual Chassis Stacking (VCStack). This
guide explains both options.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1: Overview
Features
Here are the features of the AT-IX5-28GPX switch:
10/100/1000 Here are the basic features of the 10/100/1000 Mbps twisted pair ports:
Mbps Twisted
Pair Ports
24 ports per switch
10Base-T, 100Base-TX, and 1000Base-T compliant
IEEE 802.3u Auto-Negotiation compliant
Auto-MDI/MDIX
100 meters (328 feet) maximum operating distance
IEEE 802.3x flow control in 10/100Base-TX full-duplex mode
IEEE 802.3x backpressure in 10/100Base-TX half-duplex mode
IEEE 803.3z 1000Base-T flow control
Jumbo frames up to 13KB
RJ-45 connectors
Power Over Here are the basic features of Power over Ethernet (PoE) on the twisted
pair ports:
Ethernet
Supported on ports 1 to 24
Supports PoE (15.4 watts maximum) and PoE+ (30 watts
maximum) powered devices
Supports powered device classes 0 to 4
Maximum power budget of 720 watts
Port prioritization
Mode A wiring
SFP+ Slots Here are the basic features of the four SFP+ slots on the switches:
Supports 10Gbps, 10GBase-SR/LR fiber optic transceivers
Supports 10Gbps AT-SP10TW direct connect twinax cables with
SFP+ transceiver-style connectors
Supports 1000Base-SX/LX SFP transceivers
Supports single-port BiDi 1000Base-LX SFP transceivers
Supports 1000Base-ZX SFP transceivers
Note
The SFP+ slots do not support 100Mbps 100Base-FX transceivers.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
Note
SFP and SFP+ transceivers must be purchased separately. For a
list of supported transceivers, contact your Allied Telesis distributor
or reseller.
Note
SFP+ slots 27 and 28 are initially configured as stacking slots for the
VCStack feature. If you intend to use the switch as a stand-alone
unit, you must disable the VCStack feature before using the slots
with standard SFP or SFP+ transceivers. See Chapter 5,
instructions.
Power Supply The AT-IX5-28GPX switch has two rear slots for hot-swappable power
supplies, to take one or two AT-PWR800 (800W) AC power supplies.
Modules
Stacking Slots Two SFP+ slots can be used with special stacking transceivers to create a
VCStack of up to four switches that operate as a virtual switch. Here are
the basic features of the stacking slots on the AT-IX5-28GPX switch:
Two stacking ports per switch
40Gbps stacking bandwidth
LEDs Here are the port LEDs:
PoE and link/activity LEDs for the twisted pair ports
Link/activity LEDs for the SFP+ slots
Stack ID number LED
eco-friendly button turns off the LEDs to conserve electricity
Installation Here are the installation options for the switches:
Options
19-inch equipment rack - horizontal or vertical mounting
Desk or tabletop
MAC Address Here are the basic features of the MAC address tables of the switches:
Table
Storage capacity of 16,000 dynamic MAC address entries
Storage capacity of 256 static MAC address entries
Automatic learning and aging
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1: Overview
Management Here are the management software and interfaces:
Software and
Interfaces
AlliedWare Plus Management Software
Command line interface
Web browser interface
Management Here are the methods for managing the switches:
Methods
Local management through the Console port
Remote Telnet and Secure Shell management
Remote HTTP and HTTPS web browser management
SNMPv1, v2c, and v3
18
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
Front and Rear Panels
25
SFP+ S1/27
CONSOLE
26
S2/28
1000 LINK
ACT
10/100 LINK
ACT
FDX
HDX
COL
2661
Management
Panel
10/100/1000Base-T Ports
SFP+ Slots
SFP+ or
Stacking Slots
Figure 1. Front Panel of the AT-IX5-28GPX Switch
Figure 2 on page 19 shows the back panel.
DC PWR
FAULT
DC PWR
FAULT
100-240VAC~ 5A MAX
100-240VAC~ 5A MAX
2001
Power Supply Module
Bay 1
Power Supply Module
Bay 2
Figure 2. Back Panel of the Switch
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1: Overview
Management Panel
Figure 3 identifies the components in the management panel on the AT-
IX5-28GPX switch.
Console
Management
Port
Switch
ID LED
eco-friendly
Button
USB Port
Figure 3. AT-IX5-28GPX Management Panel
20
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
10/100/1000Base-T Twisted Pair Ports
The switches have 24 10/100/1000Base-T ports.
Speed The ports can operate at 10, 100, or 1000 Mbps. The speeds may be set
manually using the management software or automatically with Auto-
Negotiation (IEEE 802.3u), the default setting.
Note
The ports must be set to Auto-Negotiation to function at 1000 Mbps
and are not compatible with devices that are not IEEE 802.3u
compliant.
Duplex Mode The twisted pair ports can operate in either half- or full-duplex mode. The
duplex mode of a port, like port speed, may be set manually using the
management software or automatically with Auto-Negotiation (IEEE
802.3u), the default setting.
The speed and duplex mode settings of a port may be set independently
of each other. For example, a port may be configured such that its speed
is set manually while its duplex mode is established through Auto-
Negotiation.
Note
A switch port should not use Auto-Negotiation to set its duplex mode
if it is connected to a network device that does not support Auto-
Negotiation for 10 or 100 Mbps operation and has a fixed duplex
mode of full-duplex. Otherwise, a duplex-mode mismatch may occur
in which a switch port and a network device operate at different
duplex modes. The duplex modes of switch ports that are connected
to network devices that do not support Auto-Negotiation should be
set manually through the management software.
Wiring The wiring configuration of a port operating at 10 or 100 Mbps can be MDI
or MDI-X. The wiring configurations of a switch port and a network device
Configuration
connected with straight-through twisted pair cabling have to be opposite,
such that one device is using MDI and the other MDI-X. For instance, a
switch port has to be set to MDI-X if it is connected to a network device set
to MDI.
You may set the wiring configurations of the ports manually or let the
switch configure them automatically with auto-MDI/MDI-X (IEEE 802.3ab-
compliant). This feature enables the switch to automatically negotiate with
network devices to establish their proper settings.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1: Overview
The MDI and MDI-X settings do not apply when ports are operating at
1000 Mbps.
Maximum The ports have a maximum operating distance of 100 meters (328 feet).
Distance
Requirements
pinouts of the 10/100/1000Base-T twisted pair ports.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
Power Over Ethernet
The AT-IX5-28GPX switch features Power over Ethernet (PoE) on the 10/
100/1000Base-T ports. PoE is used to supply power to network devices
over the same twisted pair cables that carry the network traffic.
The main advantage of PoE is that it can make it easier to install a
network. The selection of a location for a network device is often limited by
whether there is a power source nearby. This often limits equipment
placement or requires the added time and cost of having additional
electrical sources installed. But with PoE, you can install PoE-compatible
devices wherever they are needed without having to worry about whether
there are power sources nearby.
A device that provides PoE to other network devices is referred to as
power sourcing equipment (PSE). The AT-IX5-28GPX switch acts as a
PSE unit by adding DC power to the network cable, thus functioning as a
central power source for other network devices.
Devices that receive their power from a PSE are called powered devices
(PD). Examples include wireless access points, IP telephones, webcams,
and even other Ethernet switches.
The switch automatically determines whether or not a device connected to
a port is a powered device. Ports that are connected to network nodes that
are not powered devices (that is, devices that receive their power from
another power source) function as regular Ethernet ports, without PoE.
The PoE feature remains activated on the ports but no power is delivered
to the devices.
PoE Standards The AT-IX5-28GPX switch supports these PoE standards:
PoE (IEEE 802.3af): This standard provides up to 15.4 watts at the
switch port to support powered devices that require up to 12.95 watts.
PoE+ (IEEE 802.3at): This standard provides up to 30.0 watts at the
switch port to support powered devices that require up to 25.5 watts.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1: Overview
page 24. The classes are based on the amount of power the devices
require. The switches support all five classes.
Classes
Table 1. IEEE Powered Device Classes
Maximum Power Output
Class
PD Power Range
from a Switch Port
0
1
2
3
4
15.4W
0.44W to 12.95W
0.44W to 3.84W
3.84W to 6.49W
6.49W to 12.95W
12.95W to 25.5W
4.0W
7.0W
15.4W
30.0W
Cable The cable requirements for ports operating at 10 or 100Mbps are given in
Requirements
Table 2. Twisted Pair Cable Requirements for the 10/100Base-TX Ports at 10 or 100Mbps
10Mbps
PoE
100Mbps
PoE
Cable Type
Non-
PoE
Non-
PoE
PoE+
No
PoE+
No
Cat 3: Standard TIA/EIA 568-B- Yes
compliant Category 3 shielded
or unshielded cabling with 100
ohm impedance and a
Yes
Yes
Yes
frequency of 16 MHz.
Cat 5: Standard TIA/EIA 568-A- Yes
compliant Category 5 shielded
or unshielded cabling with 100
ohm impedance and a
Yes
Yes
No
Yes
Yes
Yes
Yes
No
frequency of 100 MHz.
Cat 5e: Standard TIA/EIA 568- Yes
B-compliant Enhanced
Yes
Yes
Category 5 (Cat 5e) shielded or
unshielded cabling with 100
ohm impedance and a
frequency of 100 MHz.
Cat 6 or 6a: Standard TIA/EIA
568-B-compliant Category 6 or
6a shielded cabling.
Yes
Yes
Yes
Yes
Yes
Yes
24
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
The cable requirements for ports operating at 1000Mbps are given in
Table 3. Twisted Pair Cable Requirements for the 10/100/1000Base-T
Ports at 1000Mbps
1000Mbps
Cable Type
Non-PoE
PoE
PoE+
No
Cat 3: Standard TIA/EIA 568-B- No
No
compliant Category 3 shielded
or unshielded cabling with 100
ohm impedance and a
frequency of 16 MHz.
Cat 5: Standard TIA/EIA 568-A- Yes
compliant Category 5 shielded
or unshielded cabling with 100
ohm impedance and a
Yes
Yes
No
frequency of 100 MHz.
Cat 5e: Standard TIA/EIA 568-
B-compliant Enhanced
Yes
Yes
Category 5 (Cat 5e) shielded or
unshielded cabling with 100
ohm impedance and a
frequency of 100 MHz.
Cat 6 or 6a: Standard TIA/EIA
568-B-compliant Category 6 or
6a shielded cabling.
Yes
Yes
Yes
Power Budget The AT-IX5-28GPX switch has a power budget of 720 watts when two
power supply modules are installed. This is the maximum amount of power
the switch can provide at one time to the powered devices.
Two power supplies must be installed for the switch to provide the full 720
watts. Each power supply is responsible for providing 360 watts, or half, of
the power budget. The power budget is reduced to 360 watts if only one
power supply is installed.
The power requirements of the PoE devices determine the maximum
number of devices the switch can support at one time. So long as the total
power requirements of the powered devices is less than the power budget
of the switch, the switch can supply power to all the devices. But if the total
power requirements exceed the power budget, the switch denies power to
one or more ports using a mechanism referred to as port prioritization.
To determine whether the power requirements of the PoE devices you
plan to connect to the switch exceed its power budget, refer to their
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1: Overview
documentation for their power requirements and add the requirements
together. The switch should be able to power all of the devices
simultaneously as long as the total is below its power budget. If the total
exceeds the available power budget, you should consider reducing the
number of PoE devices so that all of the devices receive power.
Otherwise, the switch powers a subset of the devices, based on port
prioritization.
The switch can handle different power requirements on different ports.
This enables you to connect different classes of PoE equipment to the
ports on the switch.
Port If the power requirements of the powered devices exceed the switch’s
power budget, the switch denies power to some ports based on a system
Prioritization
called port prioritization. You may use this mechanism to ensure that
powered devices critical to the operations of your network are given
preferential treatment by the switch in the distribution of power should the
demands of the devices exceed the available capacity.
There are three priority levels:
Critical
High
Low
Ports set to the Critical level, the highest priority level, are guaranteed
power before any of the ports assigned to the other two priority levels.
Ports assigned to the other priority levels receive power only if all the
Critical ports are receiving power. Ports that are connected to your most
critical powered devices should be assigned to this level. If there is not
enough power to support all the ports set to the Critical priority level,
power is provided to the ports based on port number, in ascending order.
The High level is the second highest level. Ports set to this level receive
power only if all the ports set to the Critical level are already receiving
power. If there is not enough power to support all of the ports set to the
High priority level, power is provided to the ports based on port number, in
ascending order.
The lowest priority level is Low. This is the default setting. Ports set to this
level only receive power if all of the ports assigned to the other two levels
are already receiving power. As with the other levels, if there is not enough
power to support all of the ports set to the Low priority level, power is
provided to the ports based on port number, in ascending order.
Power allocation is dynamic. Ports supplying power to powered devices
may cease power transmission if the switch’s power budget is at
maximum usage and new powered devices, connected to ports with
higher priorities, become active.
26
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
You can use port prioritization on dual power supply PoE switches to
protect your important networking devices from loss of power should one
of the power supplies fail or lose power. If you limit the power requirements
of the critical devices connected to a switch to less than 360 watts, the
PoE power provided by a single power supply module, a switch will have
sufficient power to support the critical devices even if it has only one
functional power supply module.
Wiring The IEEE 802.3af standard defines two methods for the delivery of DC
power over twisted pair cable by a PSE, such as the switch, to PDs. These
methods, known as modes A and B, identify the wires within the cable that
carry the DC power from the PSE to a PD.
Implementation
Twisted pair cabling typically consists of eight wires. With 10Base-T and
100Base-TX devices, the wires connected to pins 1, 2, 3, and 6 on the RJ-
45 connectors carry the network traffic while the wires connected to pins 4,
5, 7, and 8 are unused. With 1000Base-T devices, all eight wires are used
to carry network data.
It takes four wires to deliver DC power to a PD. With Mode A, the power is
delivered on pins 1, 2, 3, and 6. These are the same pins in 10Base-T and
100Base-TX devices that carry the network data. With mode B, the power
is provided over the spare wires.
The ports on the AT-IX5-28GPX switch deliver the power using pins 1, 2,
3, and 6, which corresponds to mode A in the IEEE 802.3af standard.
Powered devices that comply with the IEEE 802.3af standard are required
to support both power delivery methods. Legacy devices that do not
comply with the standard will work with the switch if they are powered on
pins 1, 2, 3, and 6.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1: Overview
SFP+ Slots
The switches have four SFP+ slots that support the following types of SFP
1000Mbps and SFP+ 10Gbps transceivers:
1000Base-SX/LX SFP transceivers
Single-port BiDi 1000Base-LX SFP transceivers
1000Base-ZX SFP transceivers
10Gbps, 10GBase-SR/LR fiber optic transceivers
10Gbps AT-SP10TW direct connect twinax cables with SFP+
transceiver-style connectors
You may use the transceivers to connect switches to other network
devices over large distances, build high-speed backbone networks
between network devices, or connect high-speed devices, such as
servers, to your network.
The switches support a variety of short and long distance SFP and SFP+
modules. For a list of supported SFP modules, contact your Allied Telesis
representative or visit our web site.
Note
SFP+ slots 27 and 28 are initially configured as stacking slots for the
VCStack feature. If you intend to use the switch as a stand-alone
unit, you must disable the VCStack feature before using the slots
with standard SFP or SFP+ transceivers. See Chapter 5,
instructions.
28
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
Stacking SFP+ Slots
Two of the four SFP+ slots on the front panel of the switch can be used
with stacking transceivers to create a VCStack of up to four AT-IX5-
28GPX switches. The switches of a VCStack act as a single virtual unit.
They synchronize their actions so that switching operations, like spanning
tree protocols, virtual LANs, and static port trunks, span across all the
units and ports. The two main advantages of stacks are:
You can manage multiple units simultaneously, which can simplify
network management.
You have more flexibility in how you configure some of the
features. For instance, a static port trunk on a stand-alone switch
has to consist of ports from the same switch. In contrast, a static
trunk on a stack may consist of ports from different switches in the
same stack.
The slots for the stacking transceivers are SFP+ slots 27 and 28.
Note
If you use the switch as a stand-alone device, you can use the slots
with regular SFP and SFP+ transceivers by disabling the VCStack
feature. See Chapter 5, “Configuring the Switch for Stand-alone
Operations” on page 77 for instructions.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1: Overview
eco-friendly Button
You may turn off the port LEDs to conserve electricity when you are not
monitoring the switch. The LEDs are toggled with the eco-friendly button
on the front panel of the switch or the ECOFRIENDLY LED and NO
ECOFRIENDLY LED commands in the Global Configuration mode of the
command line interface. The switch is said to be operating in a low power
mode when the LEDs are turned off.
Operating the switch in the low power mode with the LEDs turned off does
not interfere with the network operations of the device.
The Switch ID LED is always on, but it displays different information
depending on whether the LEDs are on or off. When the LEDs are on, the
ID LED displays the switches ID number. When the switch is operating in
the low power mode with the LEDs off, the LED indicates whether the
switch is a stand-alone unit or the master or member switch of a VCStack,
Note
Before checking or troubleshooting the network connections to the
ports on the switch, you should always check to be sure that the
LEDs are on by either pressing the eco-friendly button or issuing the
ECOFRIENDLY LED and NO ECOFRIENDLY LED commands in
the command line interface.
30
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
LEDs
Here are descriptions of the LEDs.
LEDs for the Each twisted pair port has two LEDs that display link, activity and PoE
Twisted Pair
Ports
Link/Activity
LED
PoE
LED
PoE
LED
Link/Activity
LED
Figure 4. LEDs for the 10/100/1000Base-T Ports
Table 4. LEDs on the 10/100/1000Base-T Ports
State Description
LED
Link/
Activity
LED
Solid Green A port has established an 1000 Mbps link to
a network device.
Flashing
Green
A port is transmitting or receiving data at
1000 Mbps.
Solid Amber A port has established a 10 or 100 Mbps
link to a network device.
Flashing
Amber
A port is transmitting or receiving data at 10
or 100 Mbps.
Off
A port has not established a link with
another network device or the LEDs are
turned off. To turn on the LEDs, use the
eco-friendly button.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1: Overview
Table 4. LEDs on the 10/100/1000Base-T Ports (Continued)
LED
PoE
State
Green
Description
The switch is detecting a powered device
(PD) on the port and is delivering power to it
Solid Amber The switch has shutdown PoE+ on the port
because of a fault condition.
Flashing
Amber
The switch is detecting a PD on the port but
is not delivering power to it because the
maximum power budget has been reached.
Off
This LED state can result from the following
conditions:
The port is not connected to a PD.
The PD is powered off.
The port is disabled in the
management software.
PoE is disabled on the port.
The LEDs on the Ethernet line cards
are turned off. To turn on the LEDs,
use the eco-friendly button.
LEDs for the The LEDs for the SFP+ slots are located between the slots, as shown in
Figure 5. Each SFP+ slot has one LED. The left-hand LED is for the top
slot and the right-hand LED is for the bottom slot.
SFP+ Slots
SFP+ Slot LEDs
Figure 5. SFP+ Slot LEDs
32
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
Table 5. SFP+ Slot LEDs
State Description
LED
Link/Activity Off
The slot is empty, the SFP or SFP+
transceiver has not established a link to a
network device, or the LEDs are turned
off. To turn on the LEDs, use the eco-
friendly button.
Solid green The SFP or SFP+ transceiver has
established a link at 1000 Mbps or 10
Gbps to a network device.
Flashing
green
The SFP+ transceiver is receiving or
transmitting packets to a network device
at 10 Gbps. (The LED does not flash for
activity at 1000 Mbps.).
LEDs for the SFP+ slots 27 and 28 may be used as stacking slots to build a VCStack of
up to four switches. For background information, refer to Chapter 2,
when the slots contain stacking transceivers.
Stacking Slots
Table 6. Stacking Slot LEDs
LED
State
Description
Link/Activity Off
The slot is empty, the stacking transceiver
has not established a link to a network
device, or the LEDs are turned off. To turn
on the LEDs, use the eco-friendly button.
Solid green The stacking transceiver has established
a link at 10 Gbps to another switch in the
stack.
Flashing
green
The stacking transceiver is receiving or
transmitting packets.
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1: Overview
of the switch. A stand-alone switch has the ID number 0. Switches in a
VCStack have the numbers 1 to 4. Chapter 8, “Powering On the Stack” on
page 101 has the procedure for verifying and, if necessary, changing the
ID number of the switch.
Switch
ID LED
Figure 6. Switch ID LED
The states of the LED when the switch is not operating in the low power
The switch is booting up.
The switch has encountered a fault condition.
The switch is operating as a stand-alone unit, with the ID
number 0.
The switch has an ID number of 1 to 4 as part of a VCStack.
The dot in the lower right corner flashes when the switch
accesses USB memory.
Figure 7. Switch ID LED
34
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
The switch displays the letter “F” for fault on the ID LED if it encounters
one of the following problems:
A cooling fan has failed.
An unsupported power supply module has been installed.
One of the power supplies has failed.
The internal temperature of the switch has exceeded the normal
operating range and the switch may shut down.
Note
You can use the SHOW SYSTEM ENVIRONMENT command in the
command line interface to identify the source of the problem.
The states of the LED when the switch is operating in the low power mode
The switch is the master switch of a VCStack.
The switch is operating as a stand-alone unit.
The switch is a member switch of a VCStack.
Figure 8. Switch ID LEDs in the Low Power Mode
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1: Overview
USB Port
The management panel has a USB port. You may use the port to store
configuration files on flash drives and to restore the files to switches
whose settings have been lost or corrupted, or to quickly configure
replacement units. You may also use the port and flash drives to update
the management firmware on the switches.
The port is USB2.0 compatible.
36
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
Console Port
The Console port is used to establish a management session with the
switch to configure its features and parameter settings. This type of
management uses serial RS-232 and is commonly referred to as local or
out-of-band management because it is not conducted over your network.
To perform local management, you must be at the location of the switch
and must use the management cable included with the switch.
To establish a local management session with the switch, connect a
terminal or a personal computer with a terminal emulation program to the
Console port, which has an RJ-45 style (8P8C) connector, using the
provided management cable. The cable has RJ-45 RJ-style (8P8C) and
DB-9 (D-sub 9-pin) connectors.
The Console port is set to the following specifications:
Default baud rate: 9600 bps (Range is 9600 to 115200 bps)
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
Note
These settings are for a DEC VT100 or ANSI terminal, or an
equivalent terminal emulation program.
37
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1: Overview
Power Supplies
The AT-IX5-28GPX switch has two rear slots for hot-swappable power
supplies.
The switch is supplied with a factory installed blank panel that covers both
power supply slots, and with a separate blank panel to use if you only
install one power supply.
One or two AT-PWR800 (800W) power supplies can be installed in these
Installing two power supplies provides a switch with power redundancy
and protect against interruptions to network operations in the event one of
the power supplies loses power or fails.
The switch has a PoE budget of 720 watts when both power supplies are
active and 370 watts when only one power supply is active. For further
information, refer to “Power Budget” on page 27.
range.
Warning
Power cord is used as a disconnection device. To de-energize
equipment, disconnect the power cord. ꢀ E3
Warning
This unit might have more than one power cord. To reduce the risk
of electric shock, disconnect all power cords before servicing the
unit. ꢀ E30
Note
The switches are powered on or off by connecting or disconnecting
the power cords.
DC PWR
FAULT
100-240VAC~ 12A MAX
Figure 9. AT-PWR800 Power Supply
38
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2: Virtual Chassis Stacking
Overview
Virtual Chassis Stacking (VCStack) allows you to connect up to four AT-
IX5-28GPX switches to form a virtual switch in which the devices function
as a single networking unit. The benefits of VCStack are:
Simplifies management - You can manage the devices of the stack
as a single unit, rather than individually. Your local and remote
management sessions automatically give you management
access to all the devices.
Reduces IP addresses - A stack requires only one IP address for
remote management access, thereby reducing the number of IP
addresses you have to assign to network devices, The one
address gives you management access to all the units.
Adds feature flexibility and resiliency - A stack gives you more
flexibility in how you can configure some features. For instance,
you can create port aggregators of ports from different switches in
the stack, rather than from only one switch. If you distribute the
ports of an aggregator across two or more switches in a stack, you
increase its resiliency because the aggregator will continue to
function, though at a reduced bandwidth, if one of the switches
stops functioning.
Reduces protocol requirements - Creating a stack might eliminate
your need to configure some protocols, such as the Virtual Router
Redundancy Protocol and Spanning Tree Protocol.
40
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
Stacking Slots
The AT-IX5-28GPX switches come with two stacking slots. The slots are
the last two SFP+ slots on the switches and are labeled S1/27 and S2/28.
The slots have two functions. You may use them with the VCStack feature
to build a stack of switches or, by disabling the VCStack feature, you may
use them with regular SFP or SFP+ transceivers as additional networking
slots.
The names of the slots depend on the status of the VCStack feature on the
switch. The management software refers to the slots as “S1” and “S2.”
when the VCStack feature is enabled and the slots are used with the
special stacking transceivers to create a stack.
When you disable the VCStack feature to use the slots with regular SFP or
SFP+ transceivers on a stand-alone switch, the slots are referred to as
slots 27 and 28. See Chapter 5, “Configuring the Switch for Stand-alone
Operations” on page 57 for instructions for disabling VCStack.
Note
When VCStack is enabled on the switch, the stacking slots only
install regular SFP or SFP+ transceivers in the stacking slots when
stacking is activated, the management software disables them and
enters an error message in the buffered log.
41
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2: Virtual Chassis Stacking
Stacking Transceivers
You connect the switches of the VCStack with the stacking transceivers
Table 7. Stacking Transceivers
Stacking
Transceiver Model
Cable Type
Twinax cable
Operating Distance
AT-StackXS/1.0
AT-StackOP/0.3
1 meter
62.5/125 µm multi-
mode fiber optic
cable
33 meters (108 feet)
50/125 µm multi-
mode fiber optic
cable
300 meters (984 feet)
9 kilometers
AT-StackOP/9.0
9/125 µm single-
mode fiber optic
cable
AT-StackXS/1.0
AT-StackOP/0.3
AT-StackOP/9.0
Figure 10. Stacking Transceivers
With its two SFP+ transceiver-style connectors and one meter of twinax
cable, the AT-StackXS/1.0 transceiver is appropriate in situations where
the switches are in the same equipment rack or on the same table.
The fiber optic transceivers are used to build stacks across large
distances.
42
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
Here are the transceiver guidelines:
The stacking transceivers may only be used in the stacking slots
and only with the VCStack feature. You may not use the
transceivers as regular networking ports.
The AT-StackOP/0.3 and AT-StackOP/9.0 transceivers must be
connected to other AT-StackOP/0.3 and AT-StackOP/9.0
transceivers. The transceivers do not work with other types of
network devices.
You may use different types of transceivers to connect the
switches of a stack and so build stacks of switches that are at
various distances from each other.
43
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2: Virtual Chassis Stacking
Stacking Port Topologies
The switches of a stack are connected with the S1 and S2 ports and the
stacking transceivers shown in Figure 10 on page 42.
There are two wiring configurations. The first topology is called the linear
topology. In this topology the switches are connected with a single
pathway. A stacking transceiver in one switch is connected to a stacking
transceiver in the next switch, which is connected to the next switch, and
so on. The connections must crossover to different stacking slots on the
switches. The stacking transceiver in the S1 slot in one switch must
connect to the stacking transceiver in the S2 slot in the next switch.
Figure 11 is an example of a stack of two switches in the linear topology.
The transceiver in the S1 slot on the top switch is connected to the
transceiver in the S2 slot on the bottom switch.
SFP+
25
S1/27
CONSOLE
26
S2/28
S1/27
SFP+
25
CONSOLE
26
S28
2694
Figure 11. Stack of Two Switches in the Linear Topology
Caution
The stack will not function if the connections to the S1 and S2 slots
do not crossover on the switches. The switches will not form a stack
and instead operate as stand-alone devices.
44
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
SFP+
SFP+
SFP+
SFP+
25
S1/27
CONSOLE
CONSOLE
CONSOLE
CONSOLE
26
S2/28
S1/27
25
26
25
S28
S1/27
26
25
S28
S1/27
26
S8
Figure 12. Stack of Four Switches in the Linear Topology
The second topology is called the ring topology. It is similar to the linear
topology, except that the unused stacking ports on the end switches of the
stack are connected to form a physical loop. This topology is more resilient
than the linear topology because there are two pathways through the
stack. If one pathway fails, the switches can maintain communications
through the alternate pathway. The example in Figure 13 on page 46
shows a ring topology of two switches.
45
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2: Virtual Chassis Stacking
SFP+
25
S1/27
CONSOLE
26
8
S1/27
SFP+
25
CONSOLE
26
S28
2696
Figure 13. Stack of Two Switches in the Ring Topology
Figure 14 on page 47 is an example of a stack of four switches in the ring
topology.
46
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
SFP+
SFP+
SFP+
SFP+
25
S1/27
CONSOLE
CONSOLE
CONSOLE
CONSOLE
26
S28
S1/27
25
26
25
S28
S1/27
26
25
S28
S1/27
26
S8
2697
Figure 14. Stack of Four Switches in the Ring Topology
The topologies are the same in terms of network speed and performance.
However, the ring topology is the recommended wiring configuration
because of the secondary path through the stacking ports. The two
pathways protect the switches of the stack against the loss of
communications due to a failure of a stacking port, cable, or switch.
The examples in the previous figures showed the twinax AT-StackXS/1.0
stacking transceiver. But the same rules apply to the fiber optic AT-
StackOP/0.3 and AT-StackOP/9.0 stacking transceivers. A fiber optic
transceiver in the S1 slot must crossover to a fiber optic transceiver in the
S2 slot of another switch.
47
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2: Virtual Chassis Stacking
Master and Member Switches
The stack has one master switch. The functions of the master switch
include:
Coordinating and monitoring stack operations.
Verifying that the switches are using the same version of
management software. It automatically downloads its management
software over the stacking cables to switches with different
software versions.
Verifying that the switches have different ID numbers. It
automatically assigns new ID numbers to resolve situations where
two or more switches have the same ID number.
Verifying that the stacking transceivers that connect the switches
together are cabled correctly.
The other switches are called member switches. There can be up to three
member switches in addition to the master switch. A member switch can
automatically transition to the master role if the current master switch is
removed from the stack or powered off. This ensures continued operations
of the stack even if the master switch stops operating.
Selection of the The devices compare the following numbers to choose the master switch
when the stack is reset or powered on:
Master Switch
Stack priority numbers
MAC addresses
The stack priority number is an adjustable value of 0 to 255, where the
lower the number, the higher the priority. Typically, the switch with the
lowest priority number (highest priority) becomes the master switch of a
stack. The default priority value is 128.
If the switches have the same priority values, the selection of the master
switch is based on their MAC addresses. As with the priority value, the
lower the MAC address, the higher the priority. The switch with the lowest
MAC address becomes the master switch.
If you power on the stack for the first time without adjusting the priority
values, the master switch is selected based on the MAC addresses if the
units are powered on simultaneously. If you power on the switches one at
a time, the master switch is the first switch to be powered on. This is
explained in Chapter 8, “Powering On the Stack” on page 101.
After the stack is established and operating, you may, if you choose,
change the priority settings on the individual units and so control which
switch will be the master switch after subsequent power cycles and resets.
48
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
ID Numbers Each switch must be assigned an ID number. The range is 1 to 4 and the
default is 1. The ID numbers are displayed on the ID LEDs on the front
panels of the units. You may assign the numbers yourself or you can let
the master switch assign the numbers automatically, as explained in
You use the ID numbers to identify the individual ports and switches when
you configure the devices with the commands in the management
software. For further information, refer to “Specifying Ports in the
The ID numbers are also used to identify the parameter settings that are
stored in the configuration file. When the stack is reset or power cycled,
the ID numbers identify the devices to which the parameter settings
belong.
Caution
You should not change the ID numbers of the switches after you
have started to configure the parameter settings. Otherwise, the
parameter settings might be applied to the wrong devices when you
reset or power cycle the stack.
The switches do not use the ID numbers to select the master switch. The
selection of the master switch is typically based on the priority numbers
and MAC addresses, as previously explained.
49
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2: Virtual Chassis Stacking
Specifying Ports in the Command Line Interface
The command line interface in the management software on the switch
has a parameter that you use to specify the individual ports. The
port1.0.n
Stack ID
Module ID
Port Number
Figure 15. PORT Parameter in the Command Line Interface
The first number is the switch’s ID number. The ID numbers of switches in
a stack are displayed on their ID LEDs. You can also view the ID numbers
with the SHOW STACK command in the command line interface.
The module ID value is used with multi-module products. This value does
not apply to the x510 Series switches and should always be 0.
The third value is a port number on the switch. You may specify only one
port number in a PORT parameter, but you may specify more than one
PORT parameter in many of the commands where the parameter is
supported.
Here is an example of the PORT parameter. It uses the INTERFACE
command to enter the Port Interface mode for ports 15 and 17 on the
switch with ID 2:
awplus> enable
awplus# configure terminal
awplus(config)# interface port2.0.15,port2.0.17
For instructions on the command line interface and the PORT parameter,
50
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Beginning the Installation
Reviewing Safety Precautions
Please review the following safety precautions before beginning the
installation procedure.
Note
Safety statements that have the ꢀ symbol are translated into
multiple languages in the Translated Safety Messages document at
Warning
Class 1 Laser product. ꢀ L1
Warning
Do not stare into the laser beam. ꢀ L2
Warning
Do not look directly at the fiber optic cable ends or inspect the cable
ends with an optical lens. ꢀ L6
Warning
Class 1 LED product. ꢀ L3
Warning
To prevent electric shock, do not remove the cover. No user-
serviceable parts inside. This unit contains hazardous voltages and
should only be opened by a trained and qualified technician. To
avoid the possibility of electric shock, disconnect electric power to
the product before connecting or disconnecting the LAN cables.
ꢀ E1
Warning
Do not work on equipment or cables during periods of lightning
activity. ꢀ E2
52
Download from Www.Somanuals.com. All Manuals Search And Download.
x510 Series Installation Guide for Virtual Chassis Stacking
Warning
For AC PSUs, power cord is used as a disconnection device. To de-
energize equipment, disconnect the power cord. ꢀ E3
Warning
Class I Equipment. This equipment must be earthed. The power
plug must be connected to a properly wired earth ground socket
outlet. An improperly wired socket outlet could place hazardous
voltages on accessible metal parts. ꢀ E4
Note
Pluggable Equipment. The socket outlet shall be installed near the
equipment and shall be easily accessible. ꢀ E5
Caution
Air vents must not be blocked and must have free access to the
room ambient air for cooling. ꢀ E6
Warning
Operating Temperature. This product is designed for a maximum
ambient temperature of 50 degrees C. ꢀ E57
Note
All Countries: Install product in accordance with local and National
Electrical Codes. ꢀ E8
Warning
Only trained and qualified personnel are allowed to install or replace
this equipment. ꢀ E14
Caution
Circuit Overloading: Consideration should be given to the
connection of the equipment to the supply circuit and the effect that
overloading of circuits might have on overcurrent protection and
supply wiring. Appropriate consideration of equipment nameplate
ratings should be used when addressing this concern. ꢀ E21
53
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Beginning the Installation
Caution
Risk of explosion if battery is replaced by an incorrect type. Replace
only with the same or equivalent type recommended by the
manufacturer. Dispose of used batteries according to the
manufacturer’s instructions.
Attention: Le remplacement de la batterie par une batterie de type
incorrect peut provoquer un danger d’explosion. La remplacer
uniquement par une batterie du même type ou de type équivalent
recommandée par le constructeur. Les batteries doivent être
éliminées conformément aux instructions du constructeur. ꢀ E22
Warning
Mounting of the equipment in the rack should be such that a
hazardous condition is not created due to uneven mechanical
loading. ꢀ E25
Note
Use dedicated power circuits or power conditioners to supply
reliable electrical power to the device. ꢀ E27
Warning
This unit might have more than one power cord. To reduce the risk
of electric shock, disconnect all power cords before servicing the
unit. ꢀ E30
Note
If installed in a closed or multi-unit rack assembly, the operating
ambient temperature of the rack environment may be greater than
the room ambient temperature. Therefore, consideration should be
given to installing the equipment in an environment compatible with
the manufacturer’s maximum rated ambient temperature (Tmra). ꢀ
E35
Caution
Installation of the equipment in a rack should be such that the
amount of air flow required for safe operation of the equipment is not
compromised. ꢀ E36
54
Download from Www.Somanuals.com. All Manuals Search And Download.
x510 Series Installation Guide for Virtual Chassis Stacking
Warning
Reliable earthing of rack-mounted equipment should be maintained.
Particular attention should be given to supply connections other than
direct connections to the branch circuits (e.g., use of power strips).
ꢀ E37
Warning
To reduce the risk of electric shock, the PoE ports on this product
must not connect to cabling that is routed outside the building where
this device is located. ꢀ E40
Caution
The unit does not contain serviceable components. Please return
damaged units for servicing. ꢀ E42
Warning
When you remove an SFP module from this product, the case
temperature of the SFP may exceed 40° C (158° F). Exercise
caution when handling with unprotected hands. ꢀ E43
55
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Beginning the Installation
Choosing a Site for the Switches
Observe these requirements when planning the installation of the switches
of a stack.
If you plan to install the switches in an equipment rack, check to be
sure that the rack is safely secured so that it will not tip over.
Devices in a rack should be installed starting at the bottom, with
the heavier devices near the bottom of the rack.
If you plan to install the switches on a table, check to be sure that
the table is level and stable.
The power outlet should be located near the switches and be
easily accessible.
The site should allow for easy access to the ports on the front of
the switches, so that you can easily connect and disconnect
cables, and view the port LEDs.
The site should allow for adequate air flow around the units and
through the cooling vents on the front and rear panels. (The
ventilation direction is from front to back, with the fan on the back
panel drawing the air out of the unit.)
The site should not expose the switches to moisture or water.
The site should be a dust-free environment.
The site should include dedicated power circuits or power
conditioners to supply reliable electrical power to the network
devices.
Do not install the switches in a wiring or utility box because they
will overheat and fail from inadequate airflow.
Warning
Switches should not be stacked on top of one another on a table or
desktop because that could present a personal safety hazard if you
need to move or replace switches.
56
Download from Www.Somanuals.com. All Manuals Search And Download.
x510 Series Installation Guide for Virtual Chassis Stacking
Planning a Stack
Here are the guidelines to planning a stack:
A stack can have up to four AT-IX5-28GPX switches.
Any of the switches in the stack can be the master switch.
Switches connected with AT-StackXS/1.0 stacking cables should
be installed in a standard 19-inch equipment rack and not more
than one meter apart, the length of the stacking cable. The end
switches cannot be more than one meter apart if you want to
You may use the AT-StackOP/0.3 and AT-StackOP/9.0
transceivers to build stacks of switches that are up to 300 meters
and 9 kilometers apart, respectively.
The wiring topology of the stack may be either linear or ring. Both
topologies offer the same in terms of speed, but the ring topology
adds wiring redundancy.
You can use combinations of AT-StackXS/1.0, AT-StackOP/0.3,
and AT-StackOP/9.0 cables when the individual switches of the
stack are at various distances from each other.
The switches do not need any additional software for stacking.
However, they do need stacking transceivers.
You may not install a networking device, such as a media
converter or Ethernet switch, between two fiber optic stacking
transceivers.
All switches must have the same licenses of optional features. If
you install an optional feature on one switch, you must install it on
all switches before assembling the stack.
The AT-StackOP/9.0 transceiver has a maximum operating
distance of 9 kilometers and requires 9/125 µm single-mode fiber
optic cable. The operating specifications of the transceiver are
StackOP/0.3 transceiver. The operating specifications of the
57
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Beginning the Installation
Table 8. Operating Distances of the AT-StackOP/0.3 Transceiver
Minimum Modal
Fiber Type
Bandwidth @ 850
nm (MHz*km)
Operating Range
62.5/125 µm multi-
mode fiber optic
cable
160
2 to 26 meters
(7 to 85 feet)
200
400
500
2000
2 to 33 meters
(7 to 108 feet)
50/125 µm multi-
mode fiber optic
cable
2 to 66 meters
(7 to 217 feet)
2 to 82 meters
(7 to 269 feet)
2 to 300 meters
(7 to 984 feet)
58
Download from Www.Somanuals.com. All Manuals Search And Download.
x510 Series Installation Guide for Virtual Chassis Stacking
Unpacking the Switch
Figure 16 lists the items that come with the switch. If any item is missing or
damaged, contact your Allied Telesis sales representative for assistance.
One 2 m (6.6 ft) local management cable with
RJ-45 (8P8C) and DB-9 (D-sub 9-pin)
connectors.
Two rack mounting brackets
1947
A
T
-PNL800/1200
One AT-PLN800/1200 blank panel for
covering an empty power supply bay
Twelve rack mounting bracket
screws
2047
Figure 16. Components of the switch
Note
You should retain the original packaging material in the event you
need to return the unit to Allied Telesis.
After checking the contents of the shipping containers, go to Chapter 4,
59
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Beginning the Installation
60
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4: Installing the Switch and its Power Supplies
Installing the Power Cord Retaining Clip
This section applies to AC power supply modules.
Perform the following procedure to install the power cord retaining clip on
each power supply module:
Figure 17. Power Cord Retaining Clip
2. Install the clip on the AC power connector on the power supply
module. With the ‘u’ of the clip facing down, press the sides of the clip
toward the center and insert the short ends into the holes in the
retaining bracket, as shown in Figure 18.
100-240V
A
C
~
Figure 18. Inserting the Retaining Clip into the Retaining Bracket
You are now ready to install the switches, as explained in the next
procedures.
62
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
Installing Power Supply Modules
Overview The AT-IX5-28GPX switch has two rear slots for hot-swappable power
supplies. You can install one or two AT-PWR800 power supplies.
The switch is supplied with a factory installed blank panel that covers both
power supply slots, and with a separate blank panel to use if you only
install one power supply.
The installation procedure is identical for each power supply.
Installing a To install a power supply, perform the following procedure:
Power Supply
1. Remove the module from the shipping package.
Note
Store the packaging material in a safe location. You must use the
original shipping material if you need to return the unit to Allied
Telesis.
2. Remove the blank panel from the power supply slots on the rear panel
of the switch by unscrewing it, as shown in the following figure.
Figure 19. Removing the rear panel
63
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4: Installing the Switch and its Power Supplies
3. Align the edges of the power supply module with the guides in the slot
and carefully slide the module into the chassis until it is flush with the
rear panel of the chassis, as shown below. Light pressure may be
needed to seat the module on the connector on the rear panel of the
chassis.
Caution
Do not force the power supply module into place. Doing so may
damage the connector pins on the backplane inside the chassis. If
there is resistance, remove the module and reinsert it after verifying
that the edges of the card are properly aligned in the guides in the
chassis’ module slot.
2261
D
F
A
100
-240
C
PW
UL
T
R
V
A
C~ 12A
M
AX
-WPR80
T
A
Figure 20. Installing the AT-PWR800 Power Supply Module
64
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
4. Secure the power supply module to the chassis by tightening the two
captive screws with a cross-head screwdriver, as shown below.
DC PWR
100-240
VA
F
A
UL
T
C
~
-
12A
MAX
T
A
2264
Figure 21. Securing the AT-PWR800 Power Supply Module
5. If you are going to operate the switch with a single power supply
module, install the supplied blank panel over the second power supply
module bay, as shown in the following figure. This is necessary for
correct airflow.
DC PWR
F
A
100-240
V
AC~
UL
T
-WPR80
12A
MAX
T
A
Figure 22. Installing the Blank Panel on the Power Supply Slot
the power cord installation.
65
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4: Installing the Switch and its Power Supplies
Installing the Switches on a Table or Desktop
You may install the switches on a table or desktop. Here are the
guidelines to selecting a site:
The table should be level and stable.
The power outlets should be located near the switches and be
easily accessible.
The site should allow for easy access to the ports on the front of
the switches, so that you can easily connect and disconnect
cables, and view the port LEDs.
The site should allow for adequate air flow around the units and
through the cooling vents on the front and rear panels. (The
ventilation direction is from front to back, with the fan on the back
panel drawing the air out of the unit.)
The site should not expose the switches to moisture or water.
The site should be a dust-free environment.
The site should include dedicated power circuits or power
conditioners to supply reliable electrical power to the network
devices.
The rubber feet on the bottom of the switches should be left on for
table or desktop installation.
Warning
Do not stack switches on top of one another on a table or desktop
because that could present a personal safety hazard if you need to
move or replace switches.
After placing the switches on the table or desktop, if you are installing a
VCStack” on page 85 to verify that VCStack is activated on the units.
66
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
Installing the Switch in an Equipment Rack
This procedure requires the following items:
Twelve bracket screws (included with the switch)
Two equipment rack brackets (included with the switch)
Flat-head screwdriver (not provided)
Cross-head screwdriver (not provided)
Four standard equipment rack screws (not provided)
Installation guidelines may be found in “Choosing a Site for the Switches”
on page 56. Here is the procedure for installing the switch horizontally or
vertically in a 19-inch equipment rack.
Caution
The chassis may be heavy and awkward to lift. Allied Telesis
recommends that you get assistance when mounting the chassis in
an equipment rack. ꢀ E28
1. Place the unit upside down on a level, secure surface.
H D X
F D
C
X
O L
A C T
1 0 / 1 0 0 L I N A K C T
1 0 0 0 L I N K
S 2 / 2 8
2 6
C O N S O L E
S 1 / 2 7 S F P + 2 5
2668
Figure 23. Turning the Switch Upside Down
2. Using a flat-head screwdriver, pry the rubber feet from the bottom of
the switch, as shown in Figure 24.
2
I-528GPX
2669
Figure 24. Removing the Rubber Feet
67
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4: Installing the Switch and its Power Supplies
3. Turn the switch over.
4. Attach the two rack mount brackets to the sides of the switch using the
bracket screws included with the unit. Figure 25 on page 68 illustrates
the four possible bracket positions.
I5-28GPX
10
00
LI
NK
A
CT
10
/1
00
LIN
K
A
C
T
FDX
HDX
25
CO
SFP
+
L
S1
/2
7
26
CO
N
SOL
2
/2
8
I-528GPX
10
00
LIN
K
A
CT
10
/1
00
LI
NK
A
CT
FDX
HDX
25
S
CO
F
P+
L
S1
/27
26
CO
N
S
S2
/2
2672
8
I5-28GPX
10
00
LIN
K
A
C
T
10
/10
0
L
IN
K
A
CT
FDX
HDX
25
CO
SFP
+
L
S1
/27
2
CO
S2
E
/2
8
I-528GPX
10
00
LIN
K
A
C
T
10
/1
00
LIN
K
A
CT
FDX
HDX
25
CO
SFP
+
L
S1
/27
2
CO
N
SO
S2
E
/2
8
Figure 25. Attaching the Equipment Rack Brackets
68
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
5. While another person holds the switch in the equipment rack, secure it
using standard equipment rack screws (not provided), as shown in
I-528GPX
1
0
0
0
LI
N
K
AC
T
10
/1
00
L
IN
K
AC
T
F
DX
HDX
2
5
SFP
COL
+
S
1
/2
7
2
6
CO
S
L
2
/2
8
2674
Figure 26. Mounting the Switch Horizontally in an Equipment Rack
IX5-28GPX
Figure 27. Mounting the Switch Vertically in an Equipment Rack
6. If required, repeat this procedure to install the remaining switches in
the stack.
7. Apply power to the switch or switches, as described in the following
procedures.
69
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4: Installing the Switch and its Power Supplies
Connecting AC Power to a Power Supply Module
To power on a switch with one or two AC Power Supply Modules, perform
the following procedure:
1. Position the power cord retaining clip in the up position, as shown in
100-240V
A
C
~
Figure 28. Power Cord Retaining Clip in the Up Position
2. Plug the power cord into the AC power connector on the rear panel of
secure the power cord to the unit.
Warning: Power cord is used as a disconnection device. To de-
energize equipment, disconnect the power cord. ꢀ E3
100-240V
A
C
~
Figure 29. Connecting the AC Power Cord
70
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
3. Connect the other end of the power cord to an appropriate AC power
outlet. For power specifications for the switch, refer to “Power
Warning
This unit might have more than one power supply. To reduce the risk
of electric shock, disconnect all power cords before servicing the
unit. ꢀ E30
4. Repeat the above procedure for the second PSU, if necessary.
5. Start a local management session on the unit by performing the
71
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4: Installing the Switch and its Power Supplies
Starting a Local Management Session
This procedure requires a terminal or a terminal emulator program and the
management cable that comes with the switch. To start a local
management session on the switch, perform the following procedure:
1. Connect the RJ-45 connector on the management cable to the
Console port on the front panel of the switch, as shown below.
2
5
SFP
+
S1
/27
2
6
CON
LE
S2
/2
2680
Figure 30. Connecting the Management Cable to the Console Port
2. Connect the other end of the cable to an RS-232 port on a terminal or
PC with a terminal emulator program.
3. Configure the terminal or terminal emulator program as follows:
Baud rate: 9600 bps (The baud rate of the Console Port is
adjustable from 1200 to 115200 bps. The default is 9600 bps.)
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
Note
The port settings are for a DEC VT100 or ANSI terminal, or an
equivalent terminal emulator program.
4. If you have not already done so, power up the switch as described in
the previous procedures.
72
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
Monitoring the Initialization Processes
It takes about thirty seconds for the switch to initialize its management
software programs and features, and load the default configuration. You
may monitor the progress of the initialization process by watching the
switch ID LED. It displays the number “8” for about the first 15 seconds
and then displays the number “1.”
You may also monitor the bootup sequence by connecting a terminal or
computer that has a terminal emulator program, to the Console port on the
Bootloader 2.0.15 loaded
Press <Ctrl+B> for the Boot Menu
Reading filesystem...
Loading flash:x510-5.4.3-3.7.rel...
Verifying release... OK
Booting...
Starting base/first...
Mounting virtual filesystems...
[ OK ]
[ OK ]
______________ ____
/\ \
/ \ \_
\ |
/ /______\
__/ /| ______ |
| / | ______ |
/
/
\ \ / /
\ ____ /
/______/\____\ \/ /____________/
Allied Telesis Inc.
AlliedWare Plus (TM) v5.4.2A
Current release filename: x510-5.4.3-3.7.rel
Original release filename: x510-5.4.3-3.7.rel
Built: 08-Oct-2013 10:43:42 NZDT 2013 by: maker@maker04-build
Mounting static filesystems...
Checking flash filesystem...
Mounting flash filesystem...
Checking NVS filesystem...
Mounting NVS filesystem...
Starting base/dbus...
[ OK ]
[ OK ]
[ OK ]
[ OK ]
[ OK ]
[ OK ]
[ OK ]
Starting base/syslog...
73
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4: Installing the Switch and its Power Supplies
Figure 31. Switch Initialization Messages
Starting base/loopback...
Starting base/poe_done...
Starting base/sysctl...
Received event poefw.done
Starting base/portmapper...
Received event syslog.done
[ OK ]
[ OK ]
[ OK ]
[ OK ]
Starting base/reboot-stability...
Starting base/autofs-card...
Checking system reboot stability...
Starting base/cron...
[ OK ]
[ OK ]
[ OK ]
[ OK ]
[ OK ]
[ OK ]
[ OK ]
[ OK ]
[ OK ]
Starting base/appmond...
Starting hardware/openhpi...
Starting hardware/timeout...
Starting base/inet...
Starting base/modules...
Received event modules.done
Received event board.inserted
Received event hardware.done
Starting network/startup...
Starting network/stackd...
Starting network/election.timeout...
Received event network.enabled
[ OK ]
[ OK ]
[ OK ]
Initializing HA processes:
openhpid, hostd, cntrd, nsm, auth, epsr, hsl
imiproxyd, irdpd, lldpd, loopprot, mstp
rmon, sflowd, udldd, vrrpd, imi
lacp, pdmd
Received event network.initialized
03:44:11 awplus-1 VCS[826]: No neighboring members found, unit may be in a
stand alone configuration
03:44:11 awplus-1 VCS[826]: Startup speed can be improved by adding 'no stack
1 enable' to configuration
Received event vcs.elected-master
03:44:11 awplus-1 VCS[826]: Member 1 (0015.774f.ed30) has become the Active
Master
Figure 32. Switch Initialization Messages (Continued)
74
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
Assigning Active Workload to HA processes:
hsl, nsm, rmond, sflowd, vrrpd, irdpd, lacpd
lldpd, loopprotd, mstpd, authd, epsrd, imi, imiproxyd
Received event network.activated
Loading default configuration
Warning: flash:/default.cfg does not exist, loading factory defaults.
..
done!
Received event network.configured
awplus login:
Figure 33. Switch Initialization Messages (Continued)
75
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4: Installing the Switch and its Power Supplies
76
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5
Configuring the Switch for Stand-alone
Operations
Use this chapter if you wish to operate the switch as a single stand-alone
switch, instead of stacking it with other switches.
This chapter contains the following procedures:
77
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Configuring the Switch for Stand-alone Operations
Configuring the Switch for Stand-alone Operations
Disabling After the switch has initialized its management software, examine the
switch ID LED on the front panel and do one of the following:
VCStack
If the LED is displaying “0,” the installation procedure is complete.
The switch is now ready for network operations as a stand-alone
unit. Refer to the Software Reference: AlliedWare Plus Operating
System for IX5-28GPX Switches for instructions on how to
configure the operating parameters.
If the LED is displaying a number other than “0,” perform the
following procedures to disable the VCStack feature.
Caution
You have to reset the switch as part of the procedure to disabling
the VCStack feature. Some network traffic may be lost if the device
is already connected to a live network.
Note
The initial management session of the switch must be from the
Console port.
To disable the VCStack feature to use the switch as a stand-alone unit,
perform the following procedure:
Caution
Disabling the VCStack feature requires resetting the switch. If the
switch is already connected to a live network, some network traffic
may be lost.
1. Unless you have already done so, start a local management session
as described in “Starting a Local Management Session” on page 72.
2. When prompted, enter a user name and password to log on the
switch. If this is the initial management session of the switch, enter
“manager” as the user name and “friend” as the password. The user
name and password are case sensitive.
The local management session starts when the User Exec mode
awplus>
Figure 34. User Exec Mode Prompt
78
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
Note
The User Exec mode is the first level in the command mode
interface. For complete information on the modes and commands,
refer to the Software Reference: AlliedWare Plus Operating System
3. Enter the SHOW STACK command to display the status of the
awplus> show stack
Virtual Chassis Stacking summary information
ID
1
Pending ID MAC address
0015:774f:ed30
Priority
128
Status
Ready
Role
Active Master
-
Operational Status
Standalone Unit
Stack MAC address 0015:774f:ed30
awplus(config)#
Figure 35. SHOW STACK Command
4. Review the following items:
If the Operational Status is “Stacking Hardware Disabled,” the
VCStack feature is already disabled on the switch and the SFP+
stacking slots may be used with regular SFP or SFP+ transceivers.
35 on page 79, the VCStack feature is active on the unit. You must
disable it by performing the steps in the rest of this procedure
before you can use the SFP+ stacking slots with regular SFP or
SFP+ transceivers. The reason the status says “standalone” is
because the switch considers itself a stack of one switch.
5. Move to the Global Configuration mode by entering the ENABLE and
CONFIGURE TERMINAL commands, as shown in Figure 36.
awplus> enable
awplus# configure terminal
Enter configuration commands, one per line. End with CNTL/Z
awplus(config)#
Figure 36. Moving to the Global Configuration Mode
6. To. disable the VCStack feature on the switch, enter the NO STACK
ENABLE command, which has this format:
no stack id enable
79
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Configuring the Switch for Stand-alone Operations
The ID parameter is the ID number of the switch, displayed on the ID
LED. Replace the parameter with whatever number is on the ID LED.
For example, if the ID number of the switch is 1, the default value,
enter the command as follows:
awplus(config)# no stack 1 enable
Warning; This will disable the stacking hardware on member-1.
Are you sure you want to continue? (y/n):
Figure 37. Confirmation Prompt for the NO STACK ENABLE Command
7. Type Y to disable VCStack on the switch or N to cancel the procedure.
8. Enter the EXIT command to return to the Privileged Exec mode, as
awplus(config)# exit
awplus#
Figure 38. Returning to the Privileged Exec Mode
9. Enter the WRITE command to save your change in the configuration
file. The switch displays the confirmation prompt in Figure 39 on page
awplus# write
Building configuration ...
[OK]
awplus#
Figure 39. Saving the Changes with the WRITE Command
10. Enter the REBOOT command to reboot the switch.
11. At the confirmation prompt, type “Y” for yes.
12. Wait for the switch to initialize its management software and
afterwards examine the Switch ID LED. The switch is ready for normal
network operations as a stand-alone unit when its ID number is “0.”
Refer to the Software Reference: AlliedWare Plus Operating System
for IX5-28GPX Switches for instructions on how to configure the
operating parameters. If the number is not “0,” repeat this procedure.
80
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
Confirming the Another way to confirm that VCStack is disabled on the switch is by
displaying the status of the last two SFP+ slots on the switch. These are
slots 27 and 28. If VCStack is disabled, you should be able to display the
status of the slots even when they do not have transceivers. If VCStack is
not disabled, the switch displays a message that it cannot find the slots. To
view the status of the stacking slots, perform this procedure:
Status of the
VCStack Feature
1. Start a management session on the switch. For directions, refer to
2. Log on to the switch. The default user name is “manager” and the
password is “friend”.
3. From either the User Exec mode or Privileged Exec mode, enter the
SHOW INTERFACE command to display the status of one of the last
two SFP+ slots on the switch. For example, enter this command to
view the status of slot 27:
show interface port1.0.27
If VCStack is disabled, the switch displays the status of the designated
slot. An example is shown in Figure 40 on page 81.
awplus>show interface port1.0.51
Interface port1.0.51
Scope: both
Link is DOWN, administrative state is UP
Thrash-limiting
Status Not Detected, Action learn-disable, Timeout 1(s)
Hardware is Ethernet, address is 0015.774f.ed30
index 5051 metric 1 mru 1500
configured duplex auto, configured speed auto, configured polarity auto
<UP,BROADCAST,MULTICAST>
SNMP link-status traps: Disabled
input packets 0, bytes 0, dropped 0, multicast packets 0
output packets 0, bytes 0, multicast packets 0 broadcast packets 0
Time since last state change: 0 days 00:42:49
Figure 40. Status of a Stacking Slot When VCStack is Disabled
81
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Configuring the Switch for Stand-alone Operations
not disabled, in which case you need to disable it by performing the
awplus# show interface port1.0.51
%Can’t find interface port1.0.51
awplus#
Figure 41. Status of a Stacking Slot When VCStack is Enabled
82
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
Specifying Ports in the Command Line Interface for Stand-alone
Switches
The command line interface in the management software on the switch
has a parameter that you use to specify the individual ports. The
port1.0.n
Stack ID
Module ID
Port Number
Figure 42. PORT Parameter in the Command Line Interface
The first number is the switch’s ID number. The ID number for stand-alone
switches is not the value 0 displayed on the Switch ID LEDs. Rather, it is 1.
Be sure to enter 1, not 0, as the ID number in the PORT parameter when
configuring ports on stand-alone switches.
The module ID value is used with multi-module products. This value does
not apply to the x510 Series switches and should always be 0.
The third value is a port number on the switch. You may specify only one
port number in a PORT parameter, but you may specify more than one
PORT parameter in many commands where the parameter is supported.
Here is an example of the PORT parameter on a stand-alone switch. It
uses the INTERFACE command to enter the Port Interface mode for ports
15 and 17:
awplus> enable
awplus# configure terminal
awplus(config)# interface port1.0.15,port1.0.17
For instructions on the command line interface and the PORT parameter,
83
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 5: Configuring the Switch for Stand-alone Operations
84
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 6: Verifying the Status of VCStack and Activating VCStack
Verifying the Status of VCStack
Before you install the stacking transceivers to build the stack, you should
first test the switches to determine whether the VCStack feature is
enabled or disabled, and enable it on any units where it is disabled. On
new switches, the feature should be activated because that is the default
setting. But on switches that were previously used as stand-alone units,
the feature is probably disabled and needs to be enabled.
Testing the status of VCStack is simple. You power on a switch and watch
the ID LED. If it displays a number from 1 to 4, VCStack is already
enabled. If the LED displays the number 0, the feature is disabled and
needs to be enabled.
To test the status of VCStack, perform the following procedure:
1. Power on one of the switches.
Connect a power cord to one of the power connectors on the back
panel and to an AC power source. The unit has two power connectors,
but you do not need to connect both power cords for this procedure.
2. Wait one minute for the switch to initialize its management software.
3. View the ID LED and do one of the following:
If the ID LED is displaying a number from 1 to 4 (1 is the default),
VCStack is already enabled on the switch. Power off the unit by
disconnecting the power cord and test the remaining switches in
the same manner. After testing all the switches, be sure the
switches are powered off and go to Chapter 7, “Cabling the
If the ID LED is displaying “0,” the VCStack feature is disabled on
the switch. You must enable it by performing the procedure in
86
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
Activating the VCStack Feature
Perform the following procedure to activate the VCStack feature on
switches that display the number “0” on their ID LEDs in the previous
procedure. The tasks follow on from “Monitoring the Initialization
Activating To activate VCStack, perform the following procedure:
VCStack
1. Unless you have already done so, start a local management session
2. When prompted, enter a user name and password to log on the switch.
If this is the initial management session of the switch, enter “manager”
as the user name and “friend” as the password. The user name and
password are case sensitive.
The local management session starts when the User Exec mode
awplus>
Figure 43. User Exec Mode Prompt
Note
The User Exec mode is the first level in the command mode
interface. For complete information on the modes and commands,
refer to the Software Reference: AlliedWare Plus Operating System
3. Enter the ENABLE command to move from the User Exec mode to the
Privileged Exec mode, as shown in Figure 44.
awplus> enable
awplus#
Figure 44. Moving to the Privileged Exec Mode with the ENABLE
Command
87
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 6: Verifying the Status of VCStack and Activating VCStack
4. Enter the CONFIGURE TERMINAL command to move to the Global
Configuration mode, as shown in Figure 45.
awplus# configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
awplus(config)#
Figure 45. Moving to the Global Configuration Mode with the CONFIGURE
TERMINAL Command
5. Enter the STACK ENABLE command to activate VCStack on the
awplus(config)# stack enable
% The device needs to be restarted for this change to take effect.
awplus(config)#
Figure 46. Activating VCStack with the STACK ENABLE Command
6. Enter the EXIT command to return to the Privileged Exec mode, as
awplus(config)# exit
awplus#
Figure 47. Returning to the Privileged Exec Mode with the EXIT Command
7. Enter the WRITE command to save your change, as shown in
awplus# write
Building configuration ...
[OK]
awplus#
Figure 48. Saving the Change with the WRITE Command
Note
If this is the initial management session of the switch, the WRITE
command automatically creates in flash memory a new
configuration file called DEFAULT.CFG in which it stores your
configuration change. You may change the name of the file or
designate a different file after you create the stack.
88
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
8. Restart the switch with the REBOOT command, as shown in
awplus# reboot
reboot system? (y/n):
awplus#
Figure 49. Rebooting the Switch with the REBOOT Command
9. Type “Y” for yes.
10. Wait one minute for the switch to initialize its management software.
11. Check the ID LED and do one of the following:
If the ID LED is displaying the number 1, 2, 3, or 4, VCStack is now
enabled on the switch. Power off the switch by disconnecting the
power cord and repeat the procedures in this chapter on the next
switch. If there are no further switches to test, go to Chapter 7,
If the ID LED is still displaying “0,” repeat this procedure. If the
procedure was not successful, it might be because you did not
issue the WRITE command in step 5 to save your change.
89
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 6: Verifying the Status of VCStack and Activating VCStack
90
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 7: Cabling the Stacking Ports
Cabling Switches with AT-StackXS/1.0 Transceivers
To cable the switches of the stack with AT-StackXS/1.0 transceivers,
perform the following procedure:
Warning
A transceiver can be damaged by static electricity. Be sure to
observe all standard electrostatic discharge (ESD) precautions,
such as wearing an antistatic wrist strap, to avoid damaging the
device.
1. Remove the dust plug from the S1 slot on the top switch of the stack,
25
SFP+
S1
/2
7
26
CON
SO
LE
S2/2
8
2681
Figure 50. Removing the Dust Plug from the S1 Slot
2. Remove the transceiver from its shipping container and store the
packaging material in a safe location.
92
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
5. Remove the dust cover from the S2 slot in the next switch in the stack
as shown in Figure 53 on page 95.
Note
The cable must crossover to different slots on the switches. The
stack will not work if you connect two S1 or S2 slots together.
25
SFP+
S1
/2
7
2
6
CON
SO
LE
S2/2
8
2684
Figure 53. Removing the Dust Plug from the S2 Slot
6. Remove the dust cover from the connector on the other end of the
transceiver.
95
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 7: Cabling the Stacking Ports
7. Position the transceiver with the release tab on the bottom and slide it
25
SFP+
S1
/2
7
26
CON
SO
LE
S2
/2
8
2685
Figure 54. Installing the AT-StackXS/1.0 Transceiver in Slot S2
8. Repeat this procedure to connect additional switches to the stack with
AT-StackXS/1.0 transceivers.
empty stacking slots on the top and bottom switches.
10. After connecting the stacking cables to all the switches, go to Chapter
96
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
Cabling Switches with AT-StackOP/0.3 or AT-StackOP/9.0
Transceivers
For guidelines to cabling the switches with AT-StackOP/0.3 or AT-
StackOP/9.0 fiber optic transceivers, refer to “Planning a Stack” on
page 57. To cable switches with fiber optic transceivers, perform the
following procedure:
1. Remove a dust cover from either the S1 or S2 slot on the switch.
2. To install the transceiver in the S1 slot, position it with the handle on
the handle on the bottom.
Handle
Figure 55. Handle on the AT-StackOP/0.3 and AT-StackOP/9.0
Transceivers
97
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 7: Cabling the Stacking Ports
3. Slide the transceiver into the slot until it clicks into place, as shown in
25
SFP+
S1
/2
7
26
CON
SO
LE
S2/2
8
2687
25
SFP+
S1
/27
26
CON
SO
LE
S2/2
8
2688
Figure 56. Installing the AT-StackOP/0.3 or AT-StackOP/9.0 Transceiver
98
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
25
SFP+
S1
/2
7
26
CON
SO
LE
S2/2
8
2689
Figure 57. Removing the Dust Cover from a Stacking Transceiver
5. Verify the position of the handle on the transceiver. If the transceiver is
in the S1 slot, the handle should be in the upright position, as shown in
Figure 58. If the transceiver is in the S2 slot, the handle should be in
the down position.
25
SFP+
S1
/27
26
CON
SO
LE
S2/2
8
2690
SFP Handle
Figure 58. Positioning the Handle in the Upright Position
99
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 7: Cabling the Stacking Ports
on page 100. The connector on the cable should fit snugly into the
port, and the tab should lock the connector into place.
25
SFP+
S1
/27
2
CON
SO
LE
S2/
8
2691
Figure 59. Connecting the Fiber Optic Cable to the Stacking Transceiver
7. Repeat this procedure if the switch is to have two stacking
transceivers.
8. Repeat this procedure on the other switches of the stack to install their
stacking transceivers. The connections must crossover such that a
transceiver in slot 1 connects to a transceiver in slot 2.
100
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 8
Powering On the Stack
This chapter contains the following procedures:
to control the assignment of the ID numbers to the switches of the stack.
The numbers are assigned in the order in which you power on the units.
Otherwise, perform “Powering On the Switches Simultaneously” on
page 104 to have the switches assign the numbers automatically.
After the ID numbers are assigned, you may change them with the STACK
RENUMBER command, described in the Software Reference: AlliedWare
Caution
You should not change the ID numbers of the switches after you
begin to configure the parameter settings. Otherwise, the stack
might assign configuration settings to the wrong units.
101
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 8: Powering On the Stack
Powering On the Switches Individually
This procedure explains how you can control the assignment of the ID
numbers of the switches by powering on the units one at a time during the
initial power-on sequence. The first switch is assigned ID number 1, the
next unit is assigned ID number 2, and so on. This procedure is useful
when the switches are installed in the same equipment rack and you want
to number them in sequence, such as from top to bottom, to make them
easy to identify. After the ID number are assigned, the switches retain their
assignments even when you power off or reset the stack.
During the initial power on sequence, the first switch to be powered on
becomes the master switch of the stack. However, if you do not change
the priority values of the units, the next time you reset or power cycle the
stack the units use their MAC addresses to select the master switch. This
might result in a different switch being assigned that role. However, this
does not affect their ID number assignments, the configuration of the
switches, or the manner in which you manage the stack.
This procedure assumes the following:
This is the initial power-on sequence of the stack.
You verified that VCStack is enabled on the switches, as explained
You connected the switches with stacking transceivers, as
explained in Chapter 7, “Cabling the Stacking Ports” on page 91.
The ID numbers are set to the default 1.
All the switches are powered off.
If you want to monitor the power on sequence, you may connect a terminal
or PC with a terminal emulator program to the Console port on the switch
you intend to power on first. The messages are found in “Monitoring the
To power on the switches, perform the following procedure:
1. Power on the switch you want to have ID number 1.
Connect the power cords to the connectors on the power supply
modules and to the appropriate power sources, as shown in
2. Wait one minute for the switch to initialize its management software.
The switch should be displaying the number 1 on its ID LED.
3. Power on the switch to be assigned ID number 2.
102
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
4. Wait two minutes for the new switch to join the stack as a member.
As the new switch boots up, the first switch, which has the ID number 1
and at this point is the master switch of the stack, notifies the new
switch that its current ID number is already being used and that it
should change its number to the next available number, which is 2. The
new switch responses by automatically changing its ID number to 2
and reboots. So the new switch is actually booting up twice, once with
the ID number 1 and again with its new ID number 2, which is why it
takes two minutes before the device becomes a full member of the
stack.
5. If there is a third switch, power it on and wait another two minutes for it
to join the stack as a member with the ID number 3.
6. If there is a fourth switch, power it on and wait two minutes for it to join
the stack as a member with the ID number 4.
At this point, the stack is operational.
The ID numbers are automatically stored in special files in the flash
memories of the switches and are retained by the devices even if you
reset or power cycle the stack.
103
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 8: Powering On the Stack
Powering On the Switches Simultaneously
If you want the switches of the stack to use their MAC addresses to
automatically assign the ID numbers during the initial power on sequence,
all you have to do is power them on simultaneously, rather than one at a
time as in the previous procedure. Here are the steps the switches
perform:
They initialize their management software and compare their MAC
addresses.
The switch with the lowest address is designated as the master
switch of the stack.
The master switch assigns itself the ID number 1.
The master switch assigns ID numbers to the other switches.
The other switches reset and initialize their management software
again, with their new ID numbers.
This procedure assumes the following:
This is the initial power on sequence of the stack.
You verified that VCStack is enabled on the switches, as explained
You connected the switches with stacking transceivers, as
explained in Chapter 7, “Cabling the Stacking Ports” on page 91.
.All the switches are powered off.
If you want to monitor the power on sequence, you may connect a terminal
or PC with a terminal emulator program to the Console port on any of the
switches. The messages are found in “Monitoring the Initialization
To have the switches automatically assign the ID numbers, perform the
following procedure:
1. Power on all the switches in the stack at the same time.
Connect the power cords to the connectors on the power supply
modules and to the appropriate power sources, as shown in
2. Wait two or three minutes for the switches to select a master switch
and to assign the ID numbers.
At this point, the stack is operational. The ID numbers are
automatically stored in special files in the flash memories of the
104
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
switches and are retained by the devices even if you reset or power
cycle the stack.
105
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 8: Powering On the Stack
Verifying the Stack
To verify stack operations, perform the following procedure:
1. Establish a local management session on any switch in the stack. For
instructions, refer to “Starting a Local Management Session” on
2. From the User Exec mode, enter the SHOW STACK command:
awplus> show stack
The command lists the switches in the stack. An example is shown in
awplus> show stack
Virtual Chassis Stacking summary information
ID
1
2
3
4
Pending ID
MAC address
Priority Status Role
-
-
-
-
0015:774f:ed30
0015:774f:65ab
0015:774f:d4a7
0015:774f:c431
128
128
128
128
Ready
Ready
Ready
Ready
Active Master
Member
Member
Member
Operational Status
Stack MAC address
awplus(config)#
Normal operations
0015:774f:ed30
Figure 60. SHOW STACK Command
Here are some things to consider:
The command should list all the switches in the stack. If the list is
incomplete, refer to Chapter 10, “Troubleshooting” on page 117.
The Operational Status field displays “Normal operations” when
the switches are connected in the ring topology and “Ring topology
is broken” when the switches are connected in the linear topology.
The priority values will be 128, the default value, if they have not
been changed on the switches.
Given that there is no relationship between the ID numbers and the
selection of the master switch, the active master in the SHOW
STACK command might not have the ID number 1.
3. Do one of the following:
If you want to change the priority values of the switches, go to
“Setting the Priority Numbers” on page 107. The procedure is
optional.
page 109, to continue with the installation.
106
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
Setting the This procedure is optional. It explains how to configure the priority settings
of the switches. Changing the priority settings protects the stack
Priority Numbers
configuration should you ever power on the stack with a new member
switch that has a lower MAC address than an existing master or member
switch.
This procedure assumes you are continuing directly on from the previous
procedure.
To set the priority values of the switches, perform the following procedure:
1. Use the CONFIGURE TERMINAL command to move from the
Privileged Exec mode to the Global Configuration mode, as shown in
awplus# configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
awplus(config)#
Figure 61. Moving to the Global Configuration Mode with the CONFIGURE
TERMINAL Command
2. Use the STACK PRIORITY command to set the priority numbers. The
command has this format:
stack ID_number priority priority
The ID_NUMBER parameter is the ID number of the switch whose
priority value you are setting. The range is 1 to 4. The PRIORITY
parameter is the new priority value for the switch. The range is 0 to
255. The default is 128.
Here are a couple of examples. To assign the priority value 1 to the
switch with the ID number 1, you enter this command:
awplus(config)# stack 1 priority 1
To set the priority value to 2 on the switch with the ID number 2, you
enter:
awplus(config)# stack 2 priority 2
3. After setting the priority values, enter the EXIT command to return to
the Privileged Exec mode, as shown in Figure 62 on page 107.
awplus(config)# exit
awplus#
Figure 62. Returning to the Privileged Exec Mode
107
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 8: Powering On the Stack
4. Enter the WRITE command to save your change in the configuration
file. The switch displays the confirmation prompt in Figure 63.
awplus# write
Building configuration ...
[OK]
awplus#
Figure 63. Saving the Priority Values with the WRITE Command
5. To end the management session, enter the EXIT command.
continue with the installation.
108
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 9: Cabling the Networking Ports
Cabling the Twisted Pair Ports
Here are the guidelines to cabling the 10/100/1000Base-T twisted pair
ports:
The cable specifications for the 10/100/1000Base-T twisted pair
The connectors on the cables should fit snugly into the ports, and
the tabs should lock the connectors into place.
The default setting for the wiring configurations of the ports is auto-
MDI/MDI-X. The default setting is appropriate for switch ports that
are connected to 10/100Base-TX network devices that also
support auto-MDI/MDI-X.
The default auto-MDI/MDI-X setting is not appropriate for switch
ports that are connected to 10/100Base-TX network devices that
do not support auto-MDI/MDI-X and have a fixed wiring
configuration. For switch ports connected to those types of network
devices, you should disable auto-MDI/MDI-X and set the wiring
configurations manually.
The appropriate MDI/MDI-X setting for a switch port connected to a
10/100Base-TX network device with a fixed wiring configuration
depends on the setting of the network device and whether the
switch and network device are connected with straight-through or
crossover cable. If you are using straight-through twisted pair
cable, the wiring configurations of a port on the switch and a port
on a network device must be opposite each other, such that one
port uses MDI and the other MDI-X. For example, if a network
device has a fixed wiring configuration of MDI, you must disable
auto-MDI/MDI-X on the corresponding switch port and manually
set it to MDI-X. If you are using crossover twisted pair cable, the
wiring configurations of a port on the switch and a port on a
network device must be the same.
The default speed setting for the ports is Auto-Negotiation. This
setting is appropriate for ports connected to network devices that
also support Aut-Negotiation.
The default speed setting of Auto-Negotiation is not appropriate for
ports connected to 10/100Base-TX network devices that do not
support Auto-Negotiation and have fixed speeds. For those switch
ports, you should disable Auto-Negotiation and set the port’s
speed manually to match the speeds of the network devices.
The 10/100/1000Base-T ports must be set to Auto-Negotiation, the
default setting, to operate at 1000Mbps.
The default duplex mode setting for the ports is Auto-Negotiation.
This setting is appropriate for ports connected to network devices
that also support Auto-Negotiation for duplex modes.
110
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
The default duplex mode setting of Auto-Negotiation is not
appropriate for ports connected to network devices that do not
support Auto-Negotiation and have a fixed duplex mode. You
should disable Auto-Negotiation on those ports and set their duplex
modes manually to avoid the possibility of duplex mode
mismatches. A switch port using Auto-Negotiation defaults to half-
duplex if it detects that the end node is not using Auto-Negotiation,
which can result in a mismatch if the end node is operating at a
fixed duplex mode of full-duplex.
Do not attach cables to ports of static or LACP port trunks until
after you have configured the trunks on the switch. Otherwise, the
ports will form network loops that can adversely affect network
performance.
111
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 9: Cabling the Networking Ports
Installing SFP and SFP+ Transceivers
Review the following guidelines before installing SFP or SFP+
transceivers in the switch:
SFP and SFP+ transceivers are hot-swappable. You may install
them while the chassis is powered on.
Your Allied Telesis sales representative can provide you with a list
of supported transceivers for the line cards.
The operational specifications and fiber optic cable requirements
of the transceivers are provided in the documents included with the
devices.
You should install a transceiver before connecting the fiber optic
cable.
Fiber optic transceivers are dust sensitive. Always keep the plug in
the optical bores when a fiber optic cable is not installed, or when
you store the transceiver. When you do remove the plug, keep it
for future use.
Unnecessary removal and insertion of a transceiver can lead to
premature failure.
Warning
A transceiver can be damaged by static electricity. Be sure to
observe all standard electrostatic discharge (ESD) precautions,
such as wearing an antistatic wrist strap, to avoid damaging the
device.
Note
SFP+ slots 27 and 28 are initially configured as stacking slots for the
VCStack feature. If you intend to use the switch as a stand-alone
unit, you must disable the VCStack feature before using the slots
with standard SFP or SFP+ transceivers. See Chapter 5,
instructions.
112
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
To install an SFP or SFP+ transceiver, perform the following procedure:
1. Remove the dust plug from a transceiver slot on the switch.
Figure 64 on page 113 shows the dust plug being removed from a port.
25
SF
P+
S1
/2
7
2
6
CON
SO
LE
S2/2
8
2675
Figure 64. Removing the Dust Plug from an SFP+ Slot
Note
When VCStack is enabled on the switch, slots S1/27 and S2/28 are
reserved as stacking ports and may not be used for regular SFP or
SFP+ transceivers.
2. Remove the transceiver from its shipping container and store the
packaging material in a safe location.
3. If you are installing the transceiver in a top slot, position the transceiver
with the Allied Telesis label facing up. If you are installing the
transceiver in a bottom slot, position the transceiver with the label
facing down.
113
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 9: Cabling the Networking Ports
4. Slide the transceiver into the slot until it clicks into place, as shown in
25
SFP+
S1
/27
26
CON
SO
LE
S2
/2
8
2676
Figure 65. Installing an SFP or SFP+ Transceiver
Note
If you are ready to attach the fiber optic cable to the transceiver,
continue with the next step. Otherwise, repeat steps 1 to 4 to install
the remaining SFP or SFP+ transceivers in the line cards.
25
SFP+
S1
/27
26
CON
SO
LE
S2/2
8
2677
Figure 66. Removing the Dust Cover from an SFP or SFP+ Transceiver
114
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
6. Verify the position of the handle on the SFP transceiver. If the
transceiver is in a top slot, the handle should be in the upright position,
slot, the handle should be in the down position.
25
SFP+
S1
/2
7
26
CON
SO
LE
S2/2
8
2678
SFP Handle
Figure 67. Positioning the SFP or SFP+ Handle in the Upright Position
The connector on the cable should fit snugly into the port, and the tab
should lock the connector into place.
25
SFP+
S1
/2
7
26
CON
SO
LE
S2/2
8
2679
Figure 68. Connecting a Fiber Optic Cable to an SFP or SFP+ Transceiver
8. Repeat this procedure to install additional transceivers.
115
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 9: Cabling the Networking Ports
116
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 10
Troubleshooting
This chapter contains suggestions on how to troubleshoot the switch if a
problem occurs.
Note
For further assistance, please contact Allied Telesis Technical
Problem 1: The Switch ID LED on the front of the switch is off. The switch
could be receiving no power, or the LED could be faulty.
Solutions: Try the following:
Check whether the switch is powered up, for example by listening
for fan operation, checking the port LEDs and/or starting a
management session. If it is powered up, then the Switch ID LED
may be faulty. Please contact your Allied Telesis sales
representative for assistance.
Note
The switch may be operating in low power mode, which reduces the
number of lit LED segments. To toggle in and out of low power
mode, press the eco-friendly button on the front panel of the switch.
Check whether the PSU LED is lit. If the PSU LED is green:
— Verify that the PSUs are correctly inserted. Each module must
be flush with the rear panel of the switch. You may need to
use light pressure to seat a PSU, but do not force it.
— Try inserting the PSU into the other PSU bay.
If the PSU LED is red, there may be a PSU fault. Please contact
your Allied Telesis sales representative for assistance.
If the PSU LED is not lit, then:
— Verify that the power cord is securely connected to the power
source and to the AC connector on the power supply module.
— Verify that the power outlet has power by connecting another
device to it.
117
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 10: Troubleshooting
— Try connecting the unit to another power source.
— Try a different power cord.
— Verify that the voltage from the power source is within the
required levels for your region.
Problem 2: All the port LEDs are off even though the ports are connected
to active network devices.
Solution: The switch may be operating in the low power mode. To toggle
on the LEDs, press the eco-friendly button on the front panel of the switch.
You may also toggle the LEDs off and on with the ECOFRIENDLY LED
and NO ECOFRIENDLY LED commands in the command line interface.
Problem 3: The SHOW STACK command is not displaying all the
switches in the stack.
Solutions: One or more switches cannot join the stack. Try the following:
Verify that the stacking transceivers in the S1 and S2 slots of the
switches are properly cabled. The stacking cables must crossover
to different slots on the switches. For instructions, refer to Chapter
Verify that the transceivers are fully inserted into the S1 and S2
slots.
Verify that VCStack is activated on the switches. For instructions,
It could be that the switches have incompatible versions of the
management software. When a stack forms or a new switch is
added to an existing stack, the master switch downloads its
management software to member switches that do not have the
same version. If the master switch encounters a problem
downloading the management software to a member switch, it
does not allow the device to join the stack.
118
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
Problem 4: A twisted pair port on the switch is connected to a network
device but the port’s LINK/ACT LED is off.
Solutions: The port is unable to establish a link to a network device. Try
the following:
Verify that the port is connected to the correct twisted pair cable.
This is to eliminate the possibility that the port is connected to the
wrong network device.
Verify that the network device connected to the twisted pair port is
powered on and is operating properly.
Try connecting another network device to the twisted pair port with
a different cable. If the twisted pair port is able to establish a link,
then the problem is with the cable or the other network device.
Verify that the port speed, duplex and MDI settings are valid for the
link partner. The easiest way to do this is to set all these
parameters to auto-negotiate, which is the default setting. Also see
Problem 6.
Verify that the twisted pair cable does not exceed 100 meters (328
feet).
Verify that you are using the appropriate category of twisted pair
Table 3 on page 25 for the 10/100/1000Base-T ports.
Note
A 1000Base connection may require five to ten seconds to establish
a link.
Problem 5: The LINK/ACT LED for an SFP or SFP+ transceiver is off.
Solutions: The fiber optic port on the transceiver is unable to establish a
link to a network device. Try the following:
Verify that the remote network device connected to the fiber optic
port is operating properly.
Verify that the fiber optic cable is securely connected to the port on
the SFP or SFP+ module and to the port on the remote network
device.
Check that the transceiver is fully inserted in the slot.
If you are using SFP+ slots 27 and 28, check that VCStack is
disabled on the switch. The VCStack feature has to be disabled
before you can use these slots for regular SFP or SFP+
transceivers. For instructions, refer to “Configuring the Switch for
Verify that the operating specifications of the fiber optic ports on
the transceiver and remote network device are compatible.
119
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 10: Troubleshooting
Verify that the correct type of fiber optic cabling is being used.
Verify that the port is connected to the correct fiber optic cable.
This is to eliminate the possibility that the port is connected to the
wrong remote network device.
Try connecting another network device to the fiber optic port using
a different cable. If the port is able to establish a link, then the
problem is with the cable or other network device.
Use the switch’s management software to verify that the port is
enabled.
If the remote network device is a managed device, use its
management firmware to determine whether its port is enabled.
Test the attenuation of both directions on the fiber optic cable with
a fiber optic tester to determine whether the optical signal is too
weak (sensitivity) or too strong (maximum input power).
Problem 6: Network performance between a twisted pair port on the
switch and a network device is slow.
Solution: There might be a duplex mode mismatch between the port and
the network device. This can occur when a twisted pair port using auto-
negotiation is connected to a remote device that has a fixed speed of 10 or
100 Mbps and a fixed duplex mode of full duplex. If this is the cause of the
problem, adjust the duplex mode of the port on the network device or
switch so that both ports are using the same duplex mode. You can use
either the LEDs or management software on the switch to determine the
duplex mode settings of the ports. The LEDs are described in Table 4 on
Problem 7: The switch functions intermittently.
Solutions: Check the system hardware status through the management
software:
Use the SHOW SYSTEM ENVIRONMENT command in the
Privileged Exec mode to verify that the input voltage from the
power source to the switch is stable and within the approved
operating range. The unit will shutdown if the input voltage
fluctuates above or below the approved operating range.
Use the SHOW SYSTEM ENVIRONMENT command in the
Privileged Exec mode to verify that the fan is operating correctly.
Verify that the location of the switch allows for adequate airflow.
The unit will shutdown if it is in danger of overheating.
120
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
Problem 8: The Switch ID LED on the front of the switch is flashing the
letter “F.”
Solutions: One or more of the following problems has occurred:
A cooling fan has failed.
An unsupported PSU has been installed.
One of the PSUs has failed.
The input voltage on one or both of the PSUs is outside the normal
operating range.
The internal temperature of the switch has exceeded the normal
operating range and the switch may shut down.
Note
You can use the SHOW SYSTEM ENVIRONMENT command in the
command line interface to identify the source of the problem.
Contact your Allied Telesis sales representative for assistance.Problem 9:
The switch is not providing power to a PoE device.
Solutions: Try the following:
Review the PD’s documentation to confirm that the device supports
Mode A of the IEEE 802.3at standard. Mode A is one of two modes
that define the connector pins that deliver the power from the port
on the line card to the PD. In Mode A, the power is carried on pins
1, 2, 3, and 6 on the RJ-45 port, the same pins that carry the
network traffic. The second mode, Mode B, defines pins 4, 5, 7,
and 8 as the power carriers. The AT-IX5-28GPX switch does not
support Mode B. Most powered devices are designed to accept
power by either mode, but some legacy devices may only support
one mode. This can be verified by reviewing the device’s
documentation or data sheet. Legacy devices that only support
Mode B will not work with the switch.
Check that the device’s power requirements do not exceed its
class limit (e.g. 30 W for PoE+). This can be verified by reviewing
the device’s documentation or data sheet.
Verify that you are using the appropriate category of twisted-pair
Use the management software on the switch to determine whether
PoE is enabled on the port. The default setting for PoE is enabled.
Use the management software on the switch to determine whether
the PoE power setting for the port has been reduced to a value
below the power requirements of the device.
Try connecting the device to a different port on the switch.
121
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 10: Troubleshooting
122
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A
Technical Specifications
Physical Specifications
Table 9. Physical Specifications
Dimensions
(H x W x D)
4.4 cm x 44.0 cm x 48.0 cm
(1.7 in. x 17.3 in. x 18.9 in.)
Weight
5.4 kg
Recommended Minimum
Ventilation on All Sides
10 cm (4.0 in)
Environmental Specifications
Table 10. Environmental Specifications
Operating Temperature
Storage Temperature
0° C to 50° C (32° F to 122° F)
-25° C to 70° C (-13° F to 158° F)
5% to 90% noncondensing
5% to 95% noncondensing
3,000 m (9,842 ft)
Operating Humidity
Storage Humidity
Maximum Operating Altitude
Maximum Nonoperating Altitude
4,000 m (13,100 ft)
123
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Technical Specifications
Power Specifications
Table 11. Power Specifications
Maximum Power Consumption
Input Voltage: AT-PWR800 PSU
1000W with two AT-PWR800 PSUs
100-240 VAC,10 A maximum,
50/60 Hz per input
Certifications
Table 12. Product Certifications
EMI (Emissions)
FCC Class A, EN55022 Class A,
EN61000-3-2, EN61000-3-3, VCCI
Class A, CISPR Class A, C-TICK,
CE
EMC (Immunity)
EN55024
Electrical and Laser Safety
EN60950-1 (UL-EU), UL 60950-1
(CULUS), EN60825
Compliance Marks
CE, CULUS, UL-EU, C-Tick
124
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
RJ-45 Twisted Pair Port Pinouts
Figure 69 illustrates the pin layout of the RJ-45 connectors and ports.
Figure 69. RJ-45 Socket Pin Layout (Front View)
Table 13 on page 125 lists the pin signals for 10 and 100 Mbps.
Table 13. Pin Signals for 10 and 100 Mbps
Pin
MDI Signal
TX+
MDI-X Signal
RX+
1
2
3
4
5
6
7
8
TX-
RX-
RX+
TX+
Not used
Not used
RX-
Not used
Not used
TX-
Not used
Not used
Not used
Not used
125
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Technical Specifications
Table 14 lists the pin signals when a port operating at 1000 Mbps.
Table 14. Pin Signals for 1000 Mbps
Pinout
Pair
1
2
3
4
5
6
7
8
Pair 1 +
Pair 1 -
Pair 2 +
Pair 3 +
Pair 3 -
Pair 2 -
Pair 4 +
Pair 4 -
126
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
RJ-45 Style Serial Console Port Pinouts
Table 15 lists the pin signals of the RJ-45 style serial Console port.
Table 15. RJ-45 Style Serial Console Port Pin Signals
Pin
Signal
1
2
3
4
5
6
7
8
Looped to pin 8.
Looped to pin 7.
Transmit Data
Ground
Ground
Receive Data
Looped to pin 2.
Looped to pin 1.
127
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A: Technical Specifications
Fiber Optic Specifications of the AT-StackOP/0.3 and AT-StackOP/9.0
Transceivers
Table 16 lists the fiber optic port specifications for the AT-StackOP/0.3
transceiver.
Table 16. Fiber Optic Port Specifications for the AT-StackOP/0.3 Module
General
Maximum Distances
33 m with 62.5/125 µm (core/
cladding) multimode fiber optic
cable
300 m with 50/125 µm (core/
cladding) multimode fiber optic
cable
Fiber Optic Cable
50/125 µm or 62.5/125 µm (core/
cladding) multimode fiber optic
cable
Transmitter
Wavelength
850 nm
Output Optical Power
Receiver
-7.3 dBm min.
Wavelength
850 nm
-9.9 dBm
-1 dBm
Maximum Sensitivity
Maximum Input Power
128
Download from Www.Somanuals.com. All Manuals Search And Download.
IX5-28GPX Installation Guide
Table 17 lists the fiber optic port specifications for the AT-StackOP/9.0
transceiver.
Table 17. Fiber Optic Port Specifications for the AT-StackOP/9.0
Transceiver
General
Maximum Distances
Fiber Optic Cable
9 km
9/125 µm (core/cladding) single-
mode fiber optic cable
Transmitter
Wavelength
1310 nm
Output Optical Power
-8.2 dBm min.
+0.5 dBm max.
Receiver
Wavelength
1310 nm
-14.4 dBm
0.5 dBm
Maximum Sensitivity
Maximum Input Power
129
Download from Www.Somanuals.com. All Manuals Search And Download.
|