| Washer-Extractors   Pocket Hardmount   Variable-Speed   WE-6 Control   3 2 1 6 5 4 9 8 7 0 1 9   PHM1   PHM1389C   UW35PV – UW125PV   PHM1390CN   UW150PV   Para bajar una copia de estas instrucciones   Keep These Instructions for Future Reference.   (If this machine changes ownership, this manual must accompany machine.)   Part No. F232084R16   May 2008   Download from Www.Somanuals.com. All Manuals Search And Download.   Safety Information..............................................................................   Operator Safety.....................................................................................   2 Table of   Contents   Introduction.........................................................................................   6 Specifications and Dimensions...........................................................   8 Mounting Bolt Installation Requirements   (Approved Foundations Only)............................................................ 18   Grout Placement ................................................................................... 25   Water Connection................................................................................. 29   Designs 1-4 ...................................................................................... 39   © Copyright 2008, Alliance Laundry Systems LLC   All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any   means without the expressed written consent of the publisher.   F232084   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   1 Download from Www.Somanuals.com. All Manuals Search And Download.   Safety Information   Explanation of Safety Messages   Important Safety Instructions   Precautionary statements (“DANGER,” “WARNING,”   and “CAUTION”), followed by specific instructions,   are found in this manual and on machine decals. These   precautions are intended for the personal safety of the   operator, user, servicer, and those maintaining the   machine.   WARNING   To reduce the risk of fire, electric shock,   serious injury or death to persons when   using your washer, follow these basic   precautions:   W023   DANGER   1. Read all instructions before using the washer.   DANGER indicates the presence of a   hazard that will cause severe personal   injury, death, or substantial property   damage if the danger is ignored.   2. Refer to the GROUNDING INSTRUCTIONS in   the INSTALLATION manual for the proper   grounding of the washer.   3. Do not wash textiles that have been previously   cleaned in, washed in, soaked in, or spotted with   gasoline, kerosene, waxes, cooking oils, dry-   cleaning solvents, or other flammable or   explosive substances as they give off vapors that   could ignite or explode.   WARNING   WARNING indicates the presence of a   hazard that can cause severe personal   injury, death, or substantial property   damage if the warning is ignored.   4. Do not add gasoline, dry-cleaning solvents, or   other flammable or explosive substances to the   wash water. These substances give off vapors that   could ignite or explode.   5. Under certain conditions, hydrogen gas may be   produced in a hot water system that has not been   used for two weeks or more. HYDROGEN GAS   IS EXPLOSIVE. If the hot water system has not   been used for such a period, before using a   washing machine or combination washer-dryer,   turn on all hot water faucets and let the water   flow from each for several minutes. This will   release any accumulated hydrogen gas. The gas is   flammable, do not smoke or use an open flame   during this time.   CAUTION   CAUTION indicates the presence of a   hazard that will or can cause minor   personal injury or property damage if the   caution is ignored.   Additional precautionary statements (“IMPORTANT”   and “NOTE”) are followed by specific instructions.   IMPORTANT: The word “IMPORTANT” is used   to inform the reader of specific procedures where   minor machine damage will occur if the procedure   is not followed.   6. Do not allow children to play on or in the washer.   Close supervision of children is necessary when   the washer is used near children. This is a safety   rule for all appliances.   NOTE: The word “NOTE” is used to communicate   installation, operation, maintenance or servicing   information that is important but not hazard   related.   7. Before the washer is removed from service or   discarded, remove the door to the washing   compartment.   8. Do not reach into the washer if the wash drum is   moving.   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   Download from Www.Somanuals.com. All Manuals Search And Download.   F232084   2 Safety Information   9. Do not install or store the washer where it will be   exposed to water and/or weather.   20. If the supply cord is damanged, it must be   replaced by a special cord or assembly available   from the manufacturer or its service agent.   10. Do not tamper with the controls.   21. Be sure water connections have a shut-off valve   and that fill hose connections are tight. CLOSE   the shut-off valves at the end of each wash day.   11. Do not repair or replace any part of the washer, or   attempt any servicing unless specifically   recommended in the user-maintenance   instructions or in published user-repair   instructions that the user understands and has the   skills to carry out.   22. Loading door MUST BE CLOSED any time the   washer is to fill, tumble or spin. DO NOT bypass   the loading door switch by permitting the washer   to operate with the loading door open.   12. To reduce the risk of an electric shock or fire, DO   NOT use an extension cord or an adapter to   23. Always read and follow manufacturer’s   instructions on packages of laundry and cleaning   aids. Heed all warnings or precautions. To reduce   the risk of poisoning or chemical burns, keep   them out of the reach of children at all times   (preferably in a locked cabinet).   connect the washer to the electrical power source.   13. Use washer only for its intended purpose,   washing textiles.   14. Never wash machine parts or automotive parts in   the machine. This could result in serious damage   to the basket.   24. Always follow the fabric care instructions   supplied by the textile manufacturer.   15. ALWAYS disconnect the washer from electrical   supply before attempting any service. Disconnect   the power cord by grasping the plug, not the cord.   25. Never operate the washer with any guards and/or   panels removed.   26. DO NOT operate the washer with missing or   broken parts.   16. Install the washer according to the   INSTALLATION INSTRUCTIONS. All   connections for water, drain, electrical power and   grounding must comply with local codes and be   made by licensed personnel when required.   27. DO NOT bypass any safety devices.   28. Failure to install, maintain, and/or operate this   washer according to the manufacturer’s   17. To reduce the risk of fire, textiles which have   traces of any flammable substances such as   vegetable oil, cooking oil, machine oil,   instructions may result in conditions which can   produce bodily injury and/or property damage.   NOTE: The WARNINGS and IMPORTANT   SAFETY INSTRUCTIONS appearing in this   manual are not meant to cover all possible   conditions and situations that may occur. Common   sense, caution and care must be exercised when   installing, maintaining, or operating the washer.   flammable chemicals, thinner, etc., or anything   containing wax or chemicals such as in mops and   cleaning cloths, must not be put into the washer.   These flammable substances may cause the   fabric to catch on fire by itself.   18. Do not use fabric softeners or products to   eliminate static unless recommended by the   manufacturer of the fabric softener or product.   Any problems or conditions not understood should be   reported to the dealer, distributor, service agent or the   manufacturer.   19. Keep washer in good condition. Bumping or   dropping the washer can damage safety features.   If this occurs, have washer checked by a qualified   service person.   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   Download from Www.Somanuals.com. All Manuals Search And Download.   F232084   3 Safety Information   WARNING   CAUTION   This machine must be installed, adjusted,   and serviced by qualified electrical   Be careful around the open door,   particularly when loading from a level   below the door. Impact with door edges   can cause personal injury.   maintenance personnel familiar with the   construction and operation of this type of   machinery. They must also be familiar   with the potential hazards involved.   Failure to observe this warning may result   in personal injury and/or equipment   SW025   WARNING   damage, and may void the warranty.   SW004   Never touch internal or external steam   pipes, connections, or components.   These surfaces can be extremely hot and   will cause severe burns. The steam must   be turned off and the pipe, connections,   and components allowed to cool before   IMPORTANT: Ensure that the recommended   clearaces for inspection and maintenance are   provided. Never allow the inspection and   maintenance space to be blocked.   the pipe can be touched.   SW014   CAUTION   Safety Decals   Install the machine on a level floor of   sufficient strength. Failure to do so may   result in conditions which can produce   serious injury, death and/or property   Safety decals appear at crucial locations on the   machine. Failure to maintain legible safety decals   could result in injury to the operator or service   technician.   damage.   W703   To provide personal safety and keep the machine in   proper working order, follow all maintenance and   safety procedures presented in this manual. If   questions regarding safety arise, contact the   manufacturer immediately.   Use manufacturer-authorized spare parts to avoid   safety hazards.   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   Download from Www.Somanuals.com. All Manuals Search And Download.   F232084   4 Safety Information   Do not bypass any safety devices in the machine.   Operator Safety   WARNING   WARNING   NEVER insert hands or objects into   basket until it has completely stopped.   Doing so could result in serious injury.   Never operate the machine with a   bypassed or disconnected balance   system. Operating the machine with   severe out-of-balance loads could result   in personal injury and serious equipment   SW012   To ensure the safety of machine operators, the   following maintenance checks must be performed   daily:   damage.   SW039   1. Prior to operating the machine, verify that all   warning signs are present and legible. Missing or   illegible signs must be replaced immediately.   Make certain that spares are available.   2. Check door interlock before starting operation of   the machine:   a. Attempt to start the machine with the door   open. The machine should not start with the   door open.   b. Close the door without locking it and attempt   to start the machine. The machine should not   start with the door unlocked.   c. Close and lock the door and start a cycle.   Attempt to open the door while the cycle is in   progress. The door should not open.   If the door lock and interlock are not functioning   properly, call a service technician.   3. Do not attempt to operate the machine if any of   the following conditions are present:   a. The door does not remain securely locked   during the entire cycle.   b. Excessively high water level is evident.   c. Machine is not connected to a properly   grounded circuit.   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   Download from Www.Somanuals.com. All Manuals Search And Download.   F232084   5 Introduction   Model Identification   MODEL EXAMPLE OF NAMEPLATE LOCATION   Information in this manual is applicable to these   models:   3 1 UW35PV   UW80PV   UW125PV   UW60PV   UW100PV   UW150PV   2 This manual is designed as a guide to the installation   of the Pocket Hardmount washer-extractor equipped   with the AC inverter drive.   P U S H NOTE: All information, illustrations, and   specifications contained in this manual are based   on the latest product information available at the   time of printing. We reserve the right to make   changes at any time without notice.   PHM618N   1 2 Near Supply Valves on Cagewrap   Below Inverter Exhaust Fan on Electric Heat   Box (if equipped)   Delivery Inspection   Upon delivery, visually inspect crate, protective cover,   and unit for any visible shipping damage. If the crate,   protective cover, or unit is damaged or signs of   possible damage are evident, have the carrier note the   condition on the shipping papers before the shipping   receipt is signed, or advise the carrier of the condition   as soon as it is discovered.   3 Side of AC Drive Compartment-   Figure 1   Replacement Parts   If literature or replacement parts are required, contact   the source from which the washer-extractor was   purchased or contact Alliance Laundry Systems LLC   at (920) 748-3950 for the name of the nearest   authorized parts distributor. A parts manual may be   ordered by returning the reply card provided with each   washer-extractor.   Remove the crate and protective cover as soon after   delivery as possible. If any damage is discovered upon   removal of the crate and/or protective cover, advise the   carrier and file a written claim immediately.   Nameplate Location   The nameplate is located on cagewrap, on side of AC   Inverter Drive Compartment and on Electric Heat   Contractor Box (if equipped). Always provide the   machine’s serial number and model number when   ordering parts or when seeking technical assistance.   Customer Service   For technical assistance, contact your local distributor   or call:   (920) 748-3121   Ripon, Wisconsin   A record of each washer-extractor is on file with the   manufacturer. Always provide the machine’s serial   number and model number when ordering parts or   when seeking technical assistance. Refer to Figure 1   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   Download from Www.Somanuals.com. All Manuals Search And Download.   F232084   6 Introduction   Model Number Familiarization Guide   Sample Model Number: UW60PVQU80001   Model Number Prefix   Washer-Extractor Capacity (pounds dry weight of laundry)   UW   60   Type of Electrical Control   Washer-Extractor Speed Capabilities   Electrical Characteristics   Design Series   P = WE-6 Computer   V = 7 Speeds   P V Q J = Jog Feature (UW150 Models only)   U8   0001   Option Identification (varies from machine to machine)   UW60PVQU80001   00000000000   200 – 240   19   30   50 – 60   60   3 3 720   27   500000   EXAMPLE OF NAMEPLATE   PHM587N   Figure 2   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   F232084   7 Download from Www.Somanuals.com. All Manuals Search And Download.   Specifications and Dimensions   . UWPV Models   Specifications   35   60   80   100   125   150   Overall Dimensions   Overall width, in (mm)   Overall height, in (mm)   Overall depth, in (mm)   32.5 (826)   55.5 (1410)   43.63 (1108)   36.63 (930)   64.5 (1638)   45 (1143)   41.5 (1054)   68.5 (1740)   51.5 (1308)   41.5 (1054)   68.5 (1740)   54.5 (1384)   48 (1219)   72 (1829)   58 (1473)   50.25 (1277)   79 (2007)   63 (1600)   Weight And Shipping Information   Net weight, lb (kg)   1030 (468)   1300 (590)   200 (92)   1730 (785)   330 (150)   1795 (814)   119 (3.4)   1770 (805)   360 (163)   1835 (832)   119 (3.4)   2420 (1100)   550 (250)   2970 (1347)   572 (260)*   3022 (1371)   172 (4.87)   Basket Weight, lb (kg)   150 (68)   1085 (493)   66 (1.9)   Domestic shipping weight, lb (kg)   1340 (608)   84 (2.4)   2525 (1148)   166 (4.7)   Domestic shipping volume,   ft3 (m3)   38x47x64   (970x1200x   1630)   40x49x74.5   (1016x1245x   1892)   44x60.5 x77.25   (1118x1537x   1962)   44x60.5x77.25   (1118x1537x   1962)   61.5x60x77.75   (1560x1520x   1980)   54.5x69x79   (139x176x   201)   Domestic shipping dimensions,   WxDxH, in (mm)   Export shipping weight, lb (kg)   Export shipping volume, ft3 (m3)   1150 (522)   78 (2.2)   1464 (664)   96 (2.7)   1990 (903)   134 (3.8)   2030 (921)   134 (3.8)   2800 (1270)   184 (5.3)   3350 (1520)   220 (6.3)   41x50x65.5   (1050x1280x   1670)   43x52.12x74.5   (1092x1324x   1892)   47x63.5x77.25   (1194x1613x   1962)   47x63.5x77.25   (1194x1613x   1962)   63.5x63x80   (1620x1610x   2030)   61.5x71x87   (1562x1804x   2210)   Export shipping dimensions,   WxDxH, in (mm)   Wash Cylinder Information   Cylinder diameter, in (mm)   Cylinder depth, in (mm)   26.25 (667)   18.38 (467)   5.76 (163)   0.19 (4.8)   18   32 (813)   20 (508)   9.31 (264)   0.19 (4.8)   22   36 (914)   21 (533)   12.4 (350)   0.19 (4.8)   23   36 (914)   27 (686)   15.9 (450)   0.19 (4.8)   23   42 (1067)   24 (610)   19.2 (544)   0.19 (4.8)   24   43 (1093)   27.81 (706)   23.4 (662)   0.19 (4.8)   21.5   Cylinder volume, ft3 (l)   Perforation size, in (mm)   Perforation open area,%   Door Opening Information   Door opening size, in (mm)   14.34 (364)   23.75 (603)   17.5 (445)   17.5 (445)   29 (737)   17.5 (445)   29 (737)   20 (508)   29 (737)   24.75 (629)   32 (813)   Height of door bottom above floor,   in (mm)   28.25 (718)   Drive Train Information   Number of motors in drive train   Drive motor power, hp (kW)   * Basket Only   1 1 1 1 1 1 3.0 (2.2)   5.0 (3.7)   7.5 (5.6)   7.5 (5.6)   10 (7.5)   10 (7.5)   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   F232084   8 Download from Www.Somanuals.com. All Manuals Search And Download.   Specifications and Dimensions   UWPV Models (Continued)   Specifications   35   60   80   100   125   150   Cylinder Speeds / Centrifugal Force Data   1/2 Wash/reverse, rpm (g)   Wash/reverse, rpm (g)   Distribution, rpm (g)   26 (.25)   42 (.66)   26 (.31)   40 (.73)   26 (.35)   40 (.82)   26 (.35)   40 (.82)   26 (.40)   37 (.82)   62 (2.29)   260 (40)   380 (86)   N/A   23 (.31)   36 (0.8)   83 (2.57)   325 (39)   474 (84)   533 (106)   610 (139)   795 (235)   897 (308)   71 (2.29)   305 (42)   435 (86)   483 (106)   555 (140)   720 (235)   813 (300)   73 (2.57)   325 (54)   408 (85)   456 (106)   523 (140)   671 (230)   767 (300)   70 (2.50)   325 (54)   408 (85)   456 (106)   523 (140)   601 (184)   767 (300)   61 (2.29)   262 (42)   417 (106)   417 (106)   512 (160)   573 (200)   701 (300)   Medium extract, rpm (g)   High extract l, rpm (g)   *Design U6 models   High extract 2, rpm (g)   485 (140)   534 (170)   580 (200)   High extract 3, rpm (g)   *Design U6 models   Balance Detection   Vibration switch installed   STD   STD   STD   STD   STD   STD   .006 (.15) GO   .008 (.20) NO-   GO   .008 (.20) GO   .010 (.25) NO-   GO   .008 (.20) GO   .010 (.25) NO-   GO   .008 (.20) GO   .010 (.25) NO-   GO   .006 (.15) GO   .008 (.20) NO-   GO   .013 (.33) GO   .014 (.30) NO-   GO   Switch gap setting, in   (mm)**   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   F232084   9 Download from Www.Somanuals.com. All Manuals Search And Download.   Specifications and Dimensions   Direct Steam Heating (Optional)   Steam inlet connection size,   in (mm)   1/2 (13)   1/2 (13)   1/2 (13)   1/2 (13)   3/4 (19)   3/4 (19)   Number of steam inlets   1 1 1 1 1 1 LO   W 2.1 (1.5)   3.3 (2.4)   4.6 (3.3)   5.7 (4.1)   6.7 (4.9)   8.3 (6.0)   Steam required to   raise bath   ME   D 2.3 (1.7)   2.7 (1.9)   1.4 (21.4)   3.7 (2.6)   4.1 (2.9)   2.1 (33.4)   5.2 (3.8)   6.1 (4.4)   3.1 (48.4)   6.5 (4.7)   7.6 (5.5)   3.8 (60.4)   7.8 (5.6)   9.1 (6.6)   4.6 (72.0)   9.5 (6.9)   11.1 (8.0)   5.8 (91.0)   temperature   10°F, lb (10°C, kg)   HIG   H Average consumption per   cycle, BHP (kg)   Electrical Heating (Optional)   Total electrical heating   capacity, kW   15.6   25.2   6 37.8   9 37.8   9 50.4   12   N/A   N/A   N/A   N/A   N/A   N/A   Number of electrical heating   elements   6 Electrical heating element   size, kW   2.6   4.2   4.2   4.2   4.2   LO   W 2.4 (3.6)   2.7 (4.1)   3.1 (4.7)   2.4 (3.7)   2.7 (4.1)   3.0 (4.6)   2.2 (3.4)   2.5 (3.9)   3.0 (4.5)   2.8 (4.2)   3.2 (4.8)   3.7 (5.6)   2.5 (3.8)   2.9 (4.4)   3.4 (5.1)   Time required to   raise bath   ME   D temperature   10°F, min (5°C, min)   HIG   H * ** Gap setting should be made with “GO–NO-GO” type feeler gauge.   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   F232084   10   Download from Www.Somanuals.com. All Manuals Search And Download.   Specifications and Dimensions   exact dimensions are required for construction   purposes, contact the distributor or the   manufacturer. We reserve the right to make   changes at any time without notice.   Machine Dimensions   Dimensional Clearances   Allow a minimum of 24 inches (60 cm) at the rear and   18 inches (45 cm) at the sides for maintenance,   inspection, and adjustment. Allow at least 18 inches   (45 cm) between machines in multiple installations.   WARNING   Crush hazard.   To avoid personal injury and/or property   damage, do not tip the UW150 machine   NOTE: The dimensions shown here are for   planning purposes only. They are approximate and   subject to normal manufacturing tolerances. If   more than 25 degrees in any direction.   W642   UWPV Pocket Hardmount Machine Dimensions (Refer to Figure 3 and Figure 4)   35 60 80 100 125   150   in   mm   in   mm   in   mm   in   mm   in   mm   in   mm   30.12   33.39   23.75   43.63   1/2   765   847   603   1108   13   35.63   36.63   28.25   45   905   930   718   1143   25   41.12   41.5   29   1045   1054   737   41.12   41.5   29   1045   1054   737   48   48   29   58   1.5   72   48   1219   1219   737   50.25   50.25   32   1277   1277   813   A 1 B C D 51-1/2   3 1308   76   54.5   3 1384   76   1473   38   63   1600   73   2 1 2.9   E 55.5   36   1410   914   203   1114   64.5   36   1638   914   394   1397   68-1/2   43-3/4   16-7/8   58-1/2   1740   1111   429   68.5   43-3/4   16-7/8   58-1/2   1740   1111   429   1829   1219   289   79   2007   1422   400   F 2 56   G H 8 15.52   55   11-3/8   63-3/8   15.75   70   43.88   1486   1486   1610   1778   J 1 Overhang dimensions for the optional starch dispenser are as follows:   UW35PV, 3.88 inches (9.86 cm); UW60PV, 1.75 inches (4.45 cm);   UW80PV and UW100PV, 0.33 inch (0.83 cm). (The starch dispenser does not overhang the UW125PV.) (No longer available.)   The overhang dimension for the premium wet clean module option (compatible with wet-clean-capable washer-extractors only) adds 24 inches (60.96   cm) to combined machine dimensions E and G.   2 Table 1   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   F232084   11   Download from Www.Somanuals.com. All Manuals Search And Download.   Specifications and Dimensions   1 7 2 3 4 5 6 F E C A (BASE)   G (BASE)   B (OVERALL)   D (OVERALL)   13   8 9 10   11   J 12   H 8 UW35PV – UW125PV   PHM607N   1 2 3 4 5 6 7 Emergency Stop Button   Supply Valve Box   Door Unlock Button   Supply Dispenser   Door Handle   8 9 10   11   12   Premium Wet Clean Module (Optional)   Power Input Area (Inside)   Steam Connection (Optional)   Drain   Drain (UW80PV, UW100PV and UW125PV   models only)   Spray Rinse Nozzle   Recirculation Inlet   13   Water Inlet Valves   Figure 3   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   F232084   12   Download from Www.Somanuals.com. All Manuals Search And Download.   Specifications and Dimensions   1 2 8 9 1 4 7 1 2 5 8 0 3 6 9 5 4 3 2 1 3 7 6 F 5 J 4 C A (BASE)   G (BASE)   10   E D (OVERALL)   B (OVERALL)   11   H 12   UW150PV   PHM603N   1 2 3 4 5 6 Emergency Stop Button   Supply Valve Box   Supply Dispenser   Spray Rinse Nozzle   Basket Jog Button (Optional)   Door Handle   7 8 9 10   11   12   Door Unlock Button   Recirculation Inlet   Water Inlet Valves   Power Input Area (Inside)   Steam Connection (Optional)   Drain   Figure 4   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   F232084   13   Download from Www.Somanuals.com. All Manuals Search And Download.   Specifications and Dimensions   For new foundations a bolt-locator fixture or rebar   frame is available and a preferred option. This rigid   welded assembly made of reinforcing rod and   mounting bolts is designed to be embedded in   Machine Foundation Requirements   A 12 inch (305 mm) thickness of 3500 psi reinforced   concrete foundation is absolutely necessary for all   UWPV washer-extractors because of the high extract   speed and the G-forces exerted.   The washer-extractor must be anchored to a smooth   level surface so that the entire base of the machine is   supported and rests on the mounting surface. (Do not   support the washer-extractor on only four points.)   for Floor Load Data for all model sizes. If the   foundation requirements have been met, proceed to   Mounting Bolt Installation Requirements section.   NOTE: Do not mount on wooden floors, above   ground level, or over basements. Installation must   be “slab on grade” or equal.   Thoroughness of detail must be stressed with all   foundation work to ensure a stable unit installation,   eliminating possibilities of excessive vibration during   extract.   CAUTION   Ensure that the machine is installed on a   level floor of sufficient strength and that   the recommended clearances for   inspection and maintenance are provided.   Never allow the inspection and   maintenance space to be blocked.   SW020   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   Download from Www.Somanuals.com. All Manuals Search And Download.   F232084   14   Specifications and Dimensions   5. Refill with compacted fill dirt, making sure to   allow for correct concrete thickness.   Concrete Foundation Pad   Installation   6. Wet the hole around the cement foundation well   and brush the exposed foundation with cement   grout.   A concrete foundation and pad may be constructed to   elevate the machines. Care must be exercised in the   design of the foundation pad due to the force exerted   by the machine during extract. This concrete base   (recommended not to exceed 8 inches [20.32 cm])   must be poured, reinforced with rebar and tied to the   existing 12 inch (30.48 cm) minimum floor. Refer to   7. Completely fill with a minimum of 12 inches   (305 mm) up to the existing foundation level plus   any added level for the desired elevated pad. The   concrete must be poured so that the entire   foundation and pad cures as one piece.   8. For new foundations only a bolt-locator fixture   or a rebar frame is available and a preferred   option. Embed the mounting bolts or rebar frame   as the concrete is poured. Ensure that the bolt   threads extend 2 inches (51 mm) for UW35 - 125   models and 3 inches (76 mm) for UW150 models   above floor level.   IMPORTANT: Do NOT install a pad on top of the   existing floor. The foundation and pad must be   constructed and tied together as one piece.   If the existing floor is not reinforced concrete at least   12 inches (305 mm) thick over a solid foundation, the   9. Allow concrete to dry.   1. Cut a hole larger on all sides than the machine   base through the existing floor. The foundation   should extend a minimum of 9 inches (229 mm)   for UW35 models or 12 inches (305 mm) for   UW60 - 150 models out from the machine on all   sides.   10. Proceed to Machine Mounting and Grouting   section.   NOTE: If the washer-extractor installation will   include the Premium Wet Clean Module, the   elevated base must be designed to accommodate the   additional depth of 24 inches (60.96 cm).   2. Excavate to a depth of 18 inches (457 mm) from   the top of the existing floor.   For technical assistance, contact your local distributor   or call Alliance Laundry Systems at (920) 748-3121.   3. Produce a PYRAMID-SHAPED hole by   excavating the bottom of the hole to a width 6   inches wider on each side than the width of the   top of the hole.   4. If installing a foundation and pad, prepare a form   for the above-ground portion of the foundation.   Verify that the top of the foundation is level. The   height of the foundation pad must not exceed 8   inches (203 mm) above the existing floor.   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   Download from Www.Somanuals.com. All Manuals Search And Download.   F232084   15   Specifications and Dimensions   Brush with   Cement   Grout   Brush with   Cement   Brush with   Cement   Grout   Grout   5 1 3 3 LENGTH FOR ONE   MACHINE   3 3 2 4 6 COMPACTED FILL DIRT 18 in. (457 mm) DEPTH   COMPACTED FILL DIRT18 in. (457 mm) DEPTH   PHM720N   Figure 5   80   35   60   100   125   150   12 in.   (305 mm)   12 in.   (305 mm)   12 in.   (305 mm)   12 in.   (305 mm)   12 in.   (305 mm)   12 in.   (305 mm)   1 2*   3 6 in. (152 mm)   minimum   6 in. (152 mm)   minimum   6 in. (152 mm)   minimum   6 in. (152 mm)   minimum   6 in. (152 mm)   minimum   6 in. (152 mm)   minimum   9 in.   (229 mm)   12 in.   (305 mm)   12 in.   (305 mm)   12 in.   (305 mm)   12 in.   (305 mm)   12 in.   (305 mm)   36 in.   (914 mm)   36 in.   (914 mm)   43.75 in.   (1111 mm)   43.75 in.   (1111 mm)   48 in.   (1219 mm)   47.9 in.   (1217 mm)   4 0 - 8 in.   (0 - 203 mm)   max.   0 - 8 in.   (0 - 203 mm)   max.   0 - 8 in.   (0 - 203 mm)   max.   0 - 8 in.   (0 - 203 mm)   max.   0 - 8 in.   (0 - 203 mm)   max.   0 - 8 in.   (0 - 203 mm)   max.   5 6 30.21 in.   (765 mm)   35.62 in.   (905 mm)   41.12 in.   (1044 mm)   41.12 in.   (1044 mm)   48 in.   (1219 mm)   47 in.   (1194 mm)   * Measurement of existing floor.   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   F232084   16   Download from Www.Somanuals.com. All Manuals Search And Download.   Specifications and Dimensions   Floor Load Data   Static and dynamic loads on the floor or foundation are   floors and foundations.   UWPV Pocket Hardmount Floor Load Data   Design   Series   Specifications   35   60   80   100   125   150   Static floor load, lbs (kN)   U1-U5 1271 (5.64) 1677 (7.45) 2506 (11.2) 2741 (12.2) 3571 (15.9)   3936 (17.5)   U6 and 1272 (5.66) 1677 (7.45) 2292 (10.2) 2490 (11.1) 3283 (14.6)   greater   2 Static pressure, lbs/ft   (kN/m )   U1-U5 169 (8.08) 188 (9.00)   200 (9.6)   219 (10.5)   199 (9.6)   223 (10.7)   205 (9.8)   2 202 (9.7)   4358 (19.4)   224 (11)   U6 and 169 (8.08) 187 (8.94) 184 (8.79)   greater   Dynamic floor load, lbs (kN) U1-U5 1647 (7.3) 2824 (12.6) 3683 (16.38) 3681 (16.37) 5016 (22.31)   U6 and 1648 (7.33) 2824 (12.6) 3679 (16.36) 3690 (16.41) 5011 (22.29)   greater   2 Dynamic pressure, lbs/ft   (kN/m )   U1-U5 219 (10.5) 317 (15.2) 295 (14.2)   294 (14.1)   295 (14.2)   313 (15.1)   312 (15)   2 U6 and 219 (10.5) 317 (15.2) 295 (14.2)   greater   Dynamic load frequency, Hz U1-U5   13.3   15   12   11.2   12.8   10   9.7   9.7   11.7   U6 and   13.6   12.8   greater   1 Maximum vertical load,   lbs (kN)   U1-U5 2712 (12.0) 4184 (18.6) 5493 (24.43) 5551 (24.69) 7561 (33.63)   7508 (33.4)   1208 (5.4)   16707 (22.7)   U6 and 2719 (12.1) 4168 (18.5) 5482 (24.38) 5561 (24.73) 7559 (33.62)   greater   2 Minimum vertical load,   U1-U5 582 (2.59) 1464 (6.50) 1873 (8.3)   1811 (8.1)   2471 (11)   lbs (kN)   U6 and 576 (2.56) 1450 (6.45) 1852 (8.24) 1794 (8.0) 2434 (10.8)   greater   Base moment, lb/ft (kN/m) U1-U5 4250 (5.35) 8894 (11.2) 11853 (16.1) 11849 (16.1) 16702 (22.7)   U6 and 4249 (5.8) 8895 (12.1) 11951 (16.2) 11984 (16.3) 16606 (22.5)   greater   1 Acting in the downward direction against the floor.   2 Acting in the upward direction away from the floor.   Table 2   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   F232084   17   Download from Www.Somanuals.com. All Manuals Search And Download.   Specifications and Dimensions   For new foundations a bolt-locator fixture or rebar   frame is available and a preferred option. This rigid   welded assembly made of reinforcing rod and   mounting bolts is designed to be embedded in   Mounting Bolt Installation   Requirements (Approved   Foundations Only)   NOTE: If installing expansion bolts into an   elevated concrete foundation pad, the concrete   foundation pad should extend a minimum of 9   inches (229 mm) for UW35 machines or 12 inches   (305 mm) for UW60 - 150 machines out from the   1 2 NOTE: The optional Premium Wet Clean Module   does not require permanent attachment to the floor.   3 A bolt kit consisting of eight bolts is available as an   option. UW35PV machines use 5/8-11 x 8 inch bolts.   UW60PV – UW125PV machines use 3/4-10 x 8 inch   bolts. UW150PV machines use 3/4-10 x 10 inch   grade 5 bolts. The bolts should be embedded in a   3500 psi (241 bar) minimum reinforced concrete floor   that is a minimum of 12 inches (30.48 cm) thick. Use   the mounting bolt layouts in Mounting Bolt Hole   Locations section.   4 PHM179N   On UW35PV – UW125PV machines, the threaded end   of the bolts should extend 2 inches (5.08 cm) above   the mounting surface. On UW150PV machines, the   threaded end of the bolts should extend 3 inches above   the mounting surface.   1 2 3 4 Machine Frame Base   Mounting Bolt Threads   Grouting   Reinforcing Rod   mounting bolts.   Figure 7   1 0.75 in.   (19 mm)   2 2 in.   (51 mm)   3 8 in.   (203 mm)   PHM722N   1 2 3 Machine Frame Base   Grout   Cement or Structural Epoxy   Figure 6   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   F232084   18   Download from Www.Somanuals.com. All Manuals Search And Download.   Specifications and Dimensions   7. Before grout sets completely, make a drain   opening in the rear of the washer-extractor   grouting with a stiff piece of wire; this opening   should be approximately 1/2 inch (1.27 cm) wide   to allow any surface water build-up under the   base of the machine to drain away. Do not omit   this step.   Machine Mounting and Grouting   After the concrete has cured, proceed as follows:   1. Place the washer-extractor adjacent to the   foundation. Do not attempt to move the machine   by pushing on the sides. Always insert a pry bar   or other device under the bottom frame of the   machine to move it.   8. Position the mounting bolt washers and locknuts   on the anchor bolts and fingertighten locknuts to   machine base.   2. Remove the wood skid by unscrewing the   carriage bolts holding the skid to the bottom   frame of the washer-extractor.   9. After the grout is completely dry, tighten the   locknuts by even increments – one after the other –   until all are tightened evenly and the washer-   extractor is fastened securely to the floor.   3. Place the washer-extractor carefully over the   anchor bolts. Never attempt to lift the machine by   the door handle or by pushing on the cover   panels.   10. After installing bolts using a rebar frame, torque   5/8 inch bolts (35 model) to 90 ft. lb. and torque   3/4 inch bolts (60-150 models) to 160 ft. lb.   When using bolts not specified by Alliance   Laundry Systems, refer to the specifications   provided with the bolt.   4. Raise and level the washer-extractor 0.5 inch   (1.27 cm) off the floor on three points, using   spacers such as nut fasteners.   5. Fill the space between the washer-extractor base   and the floor with a good quality non-shrinking   machinery precision grout to ensure a stable   installation. Grout completely under all frame   members. (Remove front panel and back panel to   gain access to all frame members.) Refer to   Figure 13. Force grout under machine base until   all voids are filled.   NOTE: Check and retighten the locknuts after five   to ten days of operation and every month   thereafter.   6. Remove the spacers carefully, allowing the   machine to settle into the wet grout.   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   Download from Www.Somanuals.com. All Manuals Search And Download.   F232084   19   Specifications and Dimensions   Mounting Bolt Hole Locations   28.63 in.   (727 mm)   0.75 in.   (19 mm)   43.28 in.   (1089 mm)   40.19 in.   (1022 mm)   34.16 in.   (868 mm)   26.12 in.   (664 mm)   2 in.   2 in.   (51 mm)   (51 mm)   30.12 in.   (765 mm)   UW35PV   FRONT OF MACHINE   N   PHM630N   Figure 8   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   F232084   20   Download from Www.Somanuals.com. All Manuals Search And Download.   Specifications and Dimensions   0.75 in.   (19 mm)   0.75 in.   (19 mm)   34.12 in.   (867 mm)   4.81 in.   (122 mm)   9 in.   (229 mm)   44.81 in.   (1138 mm)   36 in.   (914 mm)   39.25 in.   (997 mm)   10.75 in.   (273 mm)   1.25 in.   (32 mm)   1.25 in.   (32 mm)   34.56 in.   (878 mm)   10.69 in.   (271 mm)   2 in.   (51 mm)   2 in.   (51 mm)   31.63 in.   (803 mm)   0.75 in.   (19 mm)   35.63 in.   (905 mm)   UW60PV   FRONT OF MACHINE   PHM631N   Figure 9   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   F232084   21   Download from Www.Somanuals.com. All Manuals Search And Download.   Specifications and Dimensions   0.75 in.   (19 mm)   0.75 in.   (19 mm)   39.63 in.   (1008 mm)   6.75 in.   (171 mm)   9 in.   (229 mm)   43.75 in.   (1111 mm)   52.19 in.   (1326 mm)   13.63 in.   (346 mm)   2.25 in.   (57 mm)   46.31 in.   (1176 mm)   2.25 in.   (57 mm)   39.75 in.   (1010 mm)   13.63 in.   (346 mm)   35.12 in.   (892 mm)   3 in.   (76 mm)   3 in.   (76 mm)   41.12 in.   (1045 mm)   0.75 in.   (19 mm)   UW80PV / UW100PV   FRONT OF MACHINE   PHM632N   Figure 10   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   F232084   22   Download from Www.Somanuals.com. All Manuals Search And Download.   Specifications and Dimensions   0.75 in.   (19 mm)   0.75 in.   (19 mm)   46.5 in.   (1181 mm)   7 in.   (178 mm)   10 in.   (254 mm)   61.5 in.   (1562 mm)   15 in.   (381 mm)   55.47 in.   48 in.   (1219 mm)   (1409 mm)   48.94 in.   (1243 mm)   15.25 in.   (387 mm)   23.25 in.   (591 mm)   23.25 in.   (591 mm)   48 in.   (1219 mm)   0.75 in.   (19 mm)   UW125PV   FRONT OF MACHINE   PHM633N   Figure 11   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   F232084   23   Download from Www.Somanuals.com. All Manuals Search And Download.   Specifications and Dimensions   10.38 in.   (264 mm)   10.38 in.   (264 mm)   67.1 in.   (1704 mm)   57.4 in.   (1457 mm)   12.13 in.   (308 mm)   51.38 in.   (1305 mm)   48.13 in.   (1223 mm)   15 in.   (381 mm)   4 in.   (102 mm)   1.5 in.   (38.1 mm)   1.5 in.   (38.1 mm)   47 in.   (1193 mm)   50 in.   (1270 mm)   UW150PV   FRONT OF MACHINE   PHM634N   Figure 12   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   F232084   24   Download from Www.Somanuals.com. All Manuals Search And Download.   Specifications and Dimensions   Grout Placement   30.12 in.   (765 mm)   35.63 in.   (905 mm)   17.88 in.   (454 mm)   11.94 in.   (303 mm)   36 in.   (914 mm)   20 in.   (508 mm)   35.94 in.   (913 mm)   4.06 in. typical   (103 mm)   12 in.   (305 mm)   27.5 in.   (699 mm)   4.06 in. typical   (103 mm)   4.06 in. typical   (103 mm)   UW35PV   UW60PV   PHM574N   PHM575N   41.12 in.   (1044 mm)   41.12 in.   (1044 mm)   14 in.   (356 mm)   10.88 in.   (276 mm)   43.75 in.   (1111 mm)   43.81 in.   (1113 mm)   17.5 in.   (445 mm)   20.69 in.   (526 mm)   4.06 in. typical   (103 mm)   33 in.   (838 mm)   33 in.   (838 mm)   4.06 in. typical   (103 mm)   4.06 in. typical   (103 mm)   4.06 in. typical   (103 mm)   PHM192N   PHM576N   UW80PV   UW100PV   50 in.   (1270 mm)   34 in.   (863.6 mm)   56 in.   (1422 mm)   8 in. typical   (203.2 mm)   PHM605N   UW150PV   Figure 13   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   F232084   25   Download from Www.Somanuals.com. All Manuals Search And Download.   Specifications and Dimensions   Drain Connection Requirements   1 A drain system of adequate capacity is essential to   washer-extractor performance. Ideally, the water   should empty through a vented pipe directly into a   drain line and drain trough configurations.   2 3 4 1 ft.   (30.48 cm)   5 6 7 PHM621N   1 2 3 4 5 6 7 Rear of Machine   Drain Pipe   1 Inch Minimum Air Gap   Steel Grate   Drain Trough   Strainer   Waste Line   PHM620N   Figure 14   A flexible connection must be made to a vented drain   system to prevent an air lock and to prevent siphoning.   Figure 15   IMPORTANT: Washer-extractor must be installed   in accordance with all local codes and ordinances.   information.   Installation of additional washer-extractors will   IMPORTANT: The top of the vent must be 1 foot   (30.48 cm) lower than the bottom of the inlet valves.   require proportionately larger drain connections. Refer   If proper drain size is not available or practical, a surge   tank is required. A surge tank in conjunction with a   sump pump should be used when gravity drainage is   not possible, such as in below-ground-level   installations.   Before any deviation from specified installation   procedures is attempted, the customer or installer   should contact the distributor.   Increasing the drain hose length, installing elbows, or   causing bends will decrease drain flow rate and   increase drain times, impairing washer-extractor   performance.   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   Download from Www.Somanuals.com. All Manuals Search And Download.   F232084   26   Specifications and Dimensions   IMPORTANT: Do not route the overflow vent pipe   to a direct drain system.   For UW125PV and UW150PV Models Only   IMPORTANT: Do not block the overflow vent   above the drain line.   If water or suds flow from the overflow vent and the   machine has been verified to be operating properly   with proper water levels and correct amount of laundry   chemicals, a drain line may be added to the vent and   routed to a drain trough.   1. Remove the riveted bracket on the rear panel for   access to the overflow vent pipe.   2. Route a drain pipe from the vent pipe to a drain   trough. Drain pipe should be routed straight   across or down and be suspended above drain   trough by at least 3 inches (7.62 cm).   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   Download from Www.Somanuals.com. All Manuals Search And Download.   F232084   27   Specifications and Dimensions   Specifications   UWPV Pocket Hardmount   Drain Information   35   60   80   100   125   150   Drain connection size, I.D., in (mm)   With second drain:   2.38 (60)   3 (76)   3 (76)   3 (76)   3 (76)   3 (77)   For Premium Wet Clean option†   3 (76)   1 3 (76)   1 Number of drain outlets   With second drain:   2 2 2 2 For Premium Wet Clean option†   2 2 Drain flow capacity, gal/min (l/min)   35 (132)   64 (242)   120 (454)   9 (255)   120 (454)   11 (311)   140 (530)   13 (368)   140 (530)   13 (368)   For Premium Wet Clean option†   70 (265)   5 (142)   100 (379)   6 (170)   3 Recommended drain pit size, ft (l) ‡   †For wet-clean-capable washer-extractors only.   ‡Sized for one machine using overflow level.   Table 3   UWPV Pocket Hardmount   Drain Line Sizing   Minimum Drain I.D., in (mm)   Number of Machines   Model   1 2 3 4 3 (76.2)   3 (76.2)   4 (102)   4 (102)   4 (102)   4 (102)   3 (76.2)   4 (102)   6 (152)   6 (152)   6 (152)   6 (152)   3.5 (88.9)   6 (152)   6 (152)   6 (152)   6 (152)   6 (152)   4 (102)   35   60   6 (152)   8 (203)   8 (203)   8 (203)   8 (203)   80   100   125   150   Table 4   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   F232084   28   Download from Www.Somanuals.com. All Manuals Search And Download.   Specifications and Dimensions   Water Connection   DANGER   To avoid personal injury, recommended   inlet water temperature should be no   higher than 125° Fahrenheit (51° Celsius).   W709   UWPV Pocket Hardmount   Water Supply Information   Specifications   35   60   80/100   2 125/150   2 Number of main fill water inlets   Main fill water inlet size, in (mm)   Number of Spray Rinse water inlets   Spray rinse water inlet size, in (mm)   Recommended pressure psi (bar)   2 2 0.5 (12.7)   2 0.75 (19)   2 0.75 (19)   2 1 (25.4)   2 0.5 (12.7)   0.5 (12.7)   0.75 (19)   0.75 (19)   30 – 85 (2 – 5.7)   Inlet flow capacity (80 psi), gal/min   (l/min)   28 (106)   39 (148)   50 (189)   75 (284)   Table 5   Connections should be supplied by hot and cold water   lines of at least the sizes shown in the Water Supply   Line Sizing table. Installation of additional machines   will require proportionately larger water lines. Refer to   Table 6. Flush the water lines before connecting them   to the machine.   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   F232084   29   Download from Www.Somanuals.com. All Manuals Search And Download.   Specifications and Dimensions   To connect water service to machine with rubber   hoses, use the following procedure:   UWPV Pocket Hardmount   Water Supply Line Sizing   1. Before installing hoses, flush the water system   for at least two minutes.   Supply Line Size, in (mm)   Number   of Machines   2. Check filters in the washer-extractor’s inlet hoses   for proper fit and cleanliness before connecting.   Main   Hot/Cold   1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 (25)   1.5 (38)   2 (50)   0.75 (19)   1 (25)   3. Hang the hoses in a large loop; do not allow them   to kink.   35   60   If additional hose lengths are needed, use flexible   hoses with screen filters. Each hose should have a   screen filter installed to keep rust and other foreign   particles out of the water inlet valves.   1.25 (32)   1.5 (38)   1 (25)   2 (50)   1.25 (32)   2 (50)   1.25 (32)   1.5 (38)   2 (50)   Pressure of 30 – 85 psi (2 – 5.7 bar) provides best   performance. Although the washer-extractor will   function properly at lower pressures, increased fill   times will occur.   2 (50)   2.5 (64)   1.25 (32)   2 (50)   1 (25)   Suitable air cushions should be installed in supply   1.25 (32)   1.5 (38)   2 (50)   80   2 (50)   For machines labeled with the CE mark, backsiphon   protection devices must be installed previous of all   machine water inlet valves in accordance with   accepted European standards.   2.5 (64)   1.5 (38)   2 (50)   1 (25)   1.5 (38)   1.5 (38)   2 (50)   100   125   150   2 (50)   2.5 (64)   2 (50)   1.25 (32)   2 (50)   1 2.5 (64)   2.5 (64)   2.5 (64)   2 (50)   2 (50)   2.5 (64)   1.25 (32)   2 (50)   2.5 (64)   2.5 (64)   2.5 (64)   2 (50)   2 2.5 (64)   Table 6   P038I   1 2 Air Cushions (Risers)   Water Supply Faucets   Figure 16   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   F232084   30   Download from Www.Somanuals.com. All Manuals Search And Download.   Specifications and Dimensions   The AC inverter drive requires a clean power supply   free from voltage spikes and surges. A voltage monitor   should be used to check incoming power. The   customer’s local power company may provide such a   monitor.   Electrical Installation Requirements   IMPORTANT: Electrical ratings are subject to   change. Refer to serial decal for electrical ratings   information specific to your machine.   If input voltage measures above 230V for a 200V drive   or above 440V for a 400V drive, ask the power   company to lower the voltage. As an alternative, a   step-down transformer kit is available from the   distributor. Voltages above 250V and 490V require   additional measures. Contact the distributor or the   manufacturer for assistance.   WARNING   This machine must be installed, adjusted,   and serviced by qualified electrical   maintenance personnel familiar with the   construction and operation of this type of   machinery. They must also be familiar with   the potential hazards involved. Failure to   observe this warning may result in   personal injury and/or equipment damage,   and may void the warranty.   WARNING   Never touch terminals or components of   the AC inverter drive unless power is   disconnected and the “CHARGE”   SW004   indicator LED is off. The AC inverter drive   retains potentially deadly voltage for some   time after the power is disconnected.   There are no user-serviceable parts inside   the AC inverter drive. Tampering with the   WARNING   Dangerous voltages are present in the   electrical control box(es) and at the motor   terminals. Only qualified personnel   familiar with electrical test procedures,   test equipment, and safety precautions   should attempt adjustments and   drive will void the warranty.   SW009   DANGER   troubleshooting. Disconnect power from   the machine before removing the control   box cover, and before attempting any   When controlling the AC inverter drive   with a parameter unit, the machine’s   computer and its safety features are   bypassed. This would allow the basket to   rotate at high speeds with the door open.   When using a parameter unit to control the   AC inverter drive, a large sign should be   placed on the front of the machine   service procedures.   SW005   WARNING   Ensure that a ground wire from a proven   earth ground is connected to the ground   lug near the input power block on this   machine. Without proper grounding,   personal injury from electric shock could   occur and machine malfunctions may be   warning people of the imminent danger.   SW003   evident.   SW008   Electrical connections are made at the rear of the   control module. The machine must be connected to the   proper electrical supply shown on the identification   plate attached to the side of the control module, using   copper conductors only.   IMPORTANT: Alliance Laundry Systems   warranty does not cover compounds that fail as a   result of improper input voltage.   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   Download from Www.Somanuals.com. All Manuals Search And Download.   F232084   31   Specifications and Dimensions   The AC drive provides thermal overload protection for   the drive motor. However, a separate three-phase   circuit breaker or electrical supply disconnecting   device must be installed for complete electrical   overload protection. This prevents damage to the   motor by disconnecting all legs if one should be lost   accidentally. Check the data plate on the back of the   requirements.   1 2 Connections to   Control Module   IMPORTANT: Do NOT use fuses in place of a   circuit breaker.   (L1)   R Black   (L2)   S Blue   (L3)   T Red   CAUTION   Do not use a phase adder on any variable-   speed machine.   PHM572N   SW037   1 2 Grounding Lug: Connect to proven earth   ground   Power Input Block   The washer-extractor should be connected to an   individual branch circuit not shared with lighting or   other equipment.   Figure 17   The connection should be shielded in a liquid-tight or   approved flexible conduit with proper conductors of   correct size installed in accordance with the National   Electric Code or other applicable codes. The   connection must be made by a qualified electrician   using the wiring diagram provided with the washer-   extractor, or according to accepted European standards   for equipment labeled with the CE mark.   After electrical installation is complete, run the   machine through a test cycle and check for a clockwise   basket rotation during the extract step. If rotation is not   clockwise, disconnect the power from the machine and   have a qualified electrician reverse any 2 motor leads at   the AC drive terminal block.   50 feet (15.24 meters). Use next larger size for runs of   50 to 100 feet (15.24 to 30.48 meters). Use 2 sizes   larger for runs greater than 100 feet (30.48 meters).   For personal safety and for proper operation, the   washer-extractor must be grounded in accordance with   state and local codes. If such codes are not available,   grounding must conform with the National Electric   Code, article 250 (current edition) or accepted   European standards for equipment labeled with the CE   mark. The ground connection must be made to a   proven earth ground, not to conduit or water pipes.   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   Download from Www.Somanuals.com. All Manuals Search And Download.   F232084   32   Specifications and Dimensions   UWPV Pocket Hardmount   Electrical Specifications   Voltage Designation   Standard   Electric Heat   N P 440 – 480   380 – 415   200 – 240   200 – 240   440 – 480   380 – 415   200 – 240   200 – 240   200 – 240   50/   50/   50/   50/   50/   50/   50/   50/   3 3 3 1 3 3 3 1 3 3 3 2 3 3 3 2 4 4 15   15   15   20   15   15   15   30   20   14   14   14   12   14   14   14   10   12   2.5   2.5   2.5   4 25   22   38   30   30   50   10   10   6 6 6 35   Q T N P 6 16   17   6 Not available in this voltage.   2.5   2.5   2.5   6 33   29   66   40   40   80   8 8 3 10   10   25   6 Q T X 12   14   14   60   80   Not available in this voltage.   Not available in this voltage.   50/   60   1 or   3 2 or   3 4 or 4   N P 440 – 480   380 – 415   200 – 240   440 – 480   380 – 415   200 – 240   440 – 480   380 – 415   200 – 240   440 – 480   380 – 415   200 – 240   50/   50/   50/   50/   50/   50/   50/   50/   50/   50/   50/   50/   3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 7 7 15   15   20   15   15   20   15   15   20   15   15   20   14   14   12   14   14   12   14   14   12   14   14   12   2.5   2.5   4 66   57   99   66   57   99   66   57   132   80   70   3 4 25   25   50   25   25   50   25   25   70   Q N P 13   7 110   80   1 2.5   2.5   4 3 10   0 7 70   4 Q N P 13   7 110   80   1 2.5   2.5   4 3 12   5 7 70   4 Q N P 13   8 140   2/0   2.5   2.5   4 NOT   AVAILABLE   15   0 8 Q 14   NOTE: Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.   Table 7   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   F232084   33   Download from Www.Somanuals.com. All Manuals Search And Download.   Specifications and Dimensions   For washer-extractors equipped with optional steam   heat, install piping in accordance with approved   commercial steam practices. Steam requirements are   Steam Requirements   (Steam Heat Option Only)   WARNING   NOTE: Failure to install the supplied steam filter   may void the warranty.   Never touch internal or external steam   pipes, connections, or components. These   surfaces can be extremely hot and will   cause severe burns. The steam must be   turned off and the pipe, connections, and   components allowed to cool before the   pipe can be touched.   SW014   UWPV Pocket Hardmount   Steam Supply Information   35   60   80   100   125/150   Steam inlet connection, in   (mm)   1/2 (DN13)   1/2 (DN13)   1 1/2 (DN13)   1/2 (DN13)   3/4 (DN19)   Number of steam inlets   1 1 1 1 Recommended pressure, psi   (bar)   30 – 80   (2.0 – 5.5)   30 – 80   (2.0 – 5.5)   30 – 80   (2.0 – 5.5)   30 – 80   (2.0 – 5.5)   30 – 80   (2.0 – 5.5)   Maximum pressure, psi (bar)   80 (5.5)   80 (5.5)   80 (5.5)   80 (5.5)   80 (5.5)   Table 8   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   F232084   34   Download from Www.Somanuals.com. All Manuals Search And Download.   Specifications and Dimensions   Undiluted chemical dripping can damage the washer-   extractor. Therefore, all chemical supply dispenser   pumps should be mounted below the washer’s   injection point. All dispenser tubing should also run   below the injection point. Loops do not prevent drips if   these instructions are not followed. Failure to follow   these instructions could damage the machine and void   Injection Supply System.   Chemical Injection Supply System   WARNING   Wear eye and hand protection when   handling chemicals; always avoid direct   contact with raw chemicals. Read the   manufacturer’s directions for accidental   contact before handling chemicals.   Ensure an eye-rinse facility and an   emergency shower are within easy reach.   Check at regular intervals for chemical   leaks.   SW016   2 1 3 PHM585N   1 2 Injection Point   Chemical Dispenser Pump Outlet   3 PVC Pipe   Figure 18   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   F232084   35   Download from Www.Somanuals.com. All Manuals Search And Download.   Specifications and Dimensions   DESIGN 7 AND LATER   Connecting External Liquid Supplies to the   Washer-Extractor   1 1. Remove knockout from supply dispenser. Refer   tubing ring.   2 3 4 2. Install PG connector in hole with strain reliefs,   included in the seal nut.   5 3. Insert tubes through PG base. Do not remove   cups. Tube should extend into the plastic cup,   with the exception of the softener tube, which   should be routed to the outside of the cup.   6 4. Tighten the seal nut to prevent tubing from   escaping the assembly.   5. Before operating machine, confirm lid is   completely closed.   Do not attempt to make chemical injection electrical   connections to points other than those provided   specifically for that purpose by the factory.   Chemical Injection Supply System   PHM559N   Number of dry supply compartments   Number of liquid supply connections   5 1 2 3 4 5 6 Tubing from Pump   Seal Nut   Tubing Ring   Base   Lid   Nut   5 Liquid supply connection size, in   (mm)   0.63 (15.9)   Figure 19   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   F232084   36   Download from Www.Somanuals.com. All Manuals Search And Download.   Specifications and Dimensions   1 2 3 4 5 6 PHM553N   1 2 3 Strain Relief for Liquid Chemical Supply Lines   Supply Dispenser Lid   Nozzles   4 5 6 Dry Supply Cups   Dry Supply Insert   Polypropylene Supply Dispenser   IMPORTANT: Do not attach anything to nozzles. Air gap must be maintained.   Figure 20   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   F232084   37   Download from Www.Somanuals.com. All Manuals Search And Download.   Specifications and Dimensions   The terminal strip that furnishes the supply output   signal for the chemical injection supply pumps, is   located inside the control module at the rear. Access is   through the rear panel of the module.   Any injection system pump which requires 110VAC   must be powered by a separate external power   source.   Terminals SUPPLY 1 through SUPPLY 9 and   common provide 200 – 240VAC fused at 500mA.   These terminals may be used to provide signals to the   chemical injection system but must not be used to   provide power to the pump. Do not attempt to increase   fuse rating as this may cause damage to the washer-   extractor’s circuitry.   CAUTION   Attempting to obtain 110VAC by using L1   or L2 with the common may damage   laundry machine circuitry and/or the   chemical injection system. Using a   240VAC power wire in the washer-   extractor and an earth ground to obtain   110VAC could cause microprocessor   An external chemical injection system requiring 200 –   240VAC can be powered through LINE 1 and LINE 2   on the external supply terminal strip on UWPVQ, PVT   and PVX models. Any chemical injection system used   with UWPVN and UWPVP models must be powered   by a separate external power source.   problems.   SW028   Consult the chemical injection supply system   instructions for operational details.   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   Download from Www.Somanuals.com. All Manuals Search And Download.   F232084   38   Specifications and Dimensions   Designs 1-4   Connecting External Liquid Supplies   to the Washer-Extractor   1 Plugs are assembled inside the tubing ring.   2. Install strain reliefs, included in the seal nut.   2 3. Insert tubes through base. Do not remove cups.   Tube should extend into the plastic cup, with the   exception of the softener tube, which should be   routed to the outside of the cup.   3 4 5 4. Tighten the seal nut to prevent tubing from   escaping the assembly.   5. Before operating machine, confirm lid is   completely closed.   6 Do not attempt to make chemical injection electrical   connections to points other than those provided   specifically for that purpose by the factory.   Chemical Injection Supply System   Number of dry supply compartments   Number of liquid supply connections   5 5 Liquid supply connection size,   in (mm)   0.63 (15.9)   P041I   1 2 3 4 5 6 Tubing from Pump   Seal Nut   Tubing Ring   Base   Lid   Nut   Figure 21   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   F232084   39   Download from Www.Somanuals.com. All Manuals Search And Download.   Specifications and Dimensions   1 2 5 3 4 6 DESIGNS 1-4   P048I   1 2 3 Strain Relief for Liquid Chemical Supply Lines   Supply Dispenser Lid   Dry Supply Cups   4 5 6 Dry Supply Insert   Four Way Water Valve   Supply Dispenser   Figure 22   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   F232084   40   Download from Www.Somanuals.com. All Manuals Search And Download.   Specifications and Dimensions   NOTE: All power must be removed from the   washer-extractor before the Premium Wet Clean   Module installation instructions are executed.   Premium Wet Clean Module   Refer to installation instructions provided with   Premium Wet Clean Module for installation   instructions.   NOTE: Pump motor is prewired for 200 – 240V   input. Motor must be rewired for 380V or greater   input.   WARNING   Lock out the main power panel and lock   out the power supply to the control box   before attempting any service procedures.   SW007   © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT   Download from Www.Somanuals.com. All Manuals Search And Download.   F232084   41   |