ADC Network Router LSX 288 User Manual

High Density LSX 288-Position Panel  
Termination and Termination/Splice Configurations  
LSX 288-Position Preterminated Panel  
ADC introduces the new high-density LSX 288-position panel available preterminated  
with intrafacility (IFC) or outside plant (OSP) cables or in termination and splice configurations.  
ADCs 288-position LSX panel (with either SC or LC) offers integrated vertical cable guides  
(VCGs) within the panel, as well as on each side of the panel. VCGs effectively segregate cables,  
aiding in easy-to-follow routing paths. The angled bulkhead style panel offers additional protection  
from bends that can increase attenuation and loss.  
Features and Benefits:  
Integrated cable management  
Angled bulkhead panel  
Vertical cable guides  
Available in SC and LC connector styles and multiple fiber cable styles  
288 terminations using either SC or LC connectors  
w w w . a d c . c o m  
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  
1 - 8 0 0 - 3 6 6 - 3 8 9 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
High Density LSX 288-Position Panel  
Termination/Splice Panel  
LSX 288-Termination and Splice Panel—Splicing in the rear eliminates rack space for a  
dedicated splice point. Panel is shown here from front vantage (left) and back vantage (right)  
ADCs 288-positon LSX panel is also available in a termination and splice configuration. While ADC  
recommends off-frame splicing in high-density applications, often floor-space is limited and on-frame  
splicing is required in a high density environment. In a 18-inch deep frame*, this panel solution saves  
the valuable rack space often required for a dedicated splice panel. Panels can be ordered with 12-fiber  
ribbon or 12-fiber stranded pigtails. Splice trays and cable clamps are included within the panel.  
Termination/Splice Panels  
O rd e r i n g I n f o r m a t i o n  
Connector style  
SC/APC  
Pigtail Type  
Ribbon-Indoor  
Ribbon-Indoor  
Ribbon-Indoor  
Ribbon-Indoor  
Stranded-Indoor  
Stranded-Indoor  
Stranded-Indoor  
Stranded-Indoor  
Splice Type  
Mass Fusion  
Catalog Number  
LSX-LL5243-A-SPL  
LSX-L75243-A-SPL  
LSX-LM5243-A-SPL  
LSX-LK5243-A-SPL  
LSX-LL1242-A-SPL  
LSX-L71242-A-SPL  
LSX-LM1242-A-SPL  
LSX-LK1242-A-SPL  
SC/UPC  
Mass Fusion  
LC/APC  
Mass Fusion  
LC/UPC  
Mass Fusion  
SC/APC  
Heatshrink Fusion  
Heatshrink Fusion  
Heatshrink Fusion  
Heatshrink Fusion  
SC/UPC  
LC/APC  
LC/UPC  
Other configurations are available upon request. Please contact ADC Technical Assistance Center.  
*See page 5 for additional accessories that accommodate the deeper panel.  
w w w . a d c . c o m  
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  
1 - 8 0 0 - 3 6 6 - 3 8 9 1  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
High Density LSX 288-Position Panel  
High-Density Distribution Solution (using 288-Termination-Only panel)  
39  
35  
30  
25  
20  
2.1 m (7')  
CABLE TIE  
BRACKETS  
15  
10  
5
1
2" BUMPER GB  
203 mm  
(8")  
660 mm  
(26")  
381 mm  
(15")  
3.4 m (11')  
aDC’s recommended fiber frame lineup uses four frames with 2 mm fiber  
jumpers to maintain the industry standard 2-inch patch cord pile-up  
The preterminated LSX-288 solution utilizes a traditional frame designed to fit a variety of termination,  
splice and storage applications. This front load frame is built to ensure commonality with patch cord  
routing, slack storage and fiber protection. It is shipped complete with top and bottom troughs.  
Available accessories include interbay management panels (IMPs).  
Density Recommendations  
Panels/Frame  
Terminations/Frame  
Recommended maximum Frame Lineup  
5
1,440  
4 frames (5,760 terminations)  
Recommended Patch Cord Lengths  
Number of Frames  
approximate Patch Cord Length  
5 m (16.4')  
1
2
3
4
6 m (19.7')  
6 m (19.7')  
7 m (23')  
O rd e r i n g I n f o r m a t i o n  
Description  
Dimensions (H x W x D)  
Catalog Number  
High-Density Frame (includes 8" deep front troughs)  
2.1 m x 660 mm x 381 mm  
(7' x 26" x 15")  
E-501-LGX-HD  
Interbay Management Panel (includes 8" deep  
troughs and spools)  
2.1 m x 127 mm x 381 mm  
(7' x 5" x 15")  
E-501-L139-HD  
288-Termination-Only Distribution Panel  
279 mm x 584 mm x 305 mm  
(11" x 23" x 12")  
Refer to previous  
pages for catalog  
numbers  
End Guard  
2.1 m x 64 mm x 381 mm  
(7' x 2.5" x 15")  
RAC-7B0162  
w w w . a d c . c o m  
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  
1 - 8 0 0 - 3 6 6 - 3 8 9 1  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
High Density LSX 288-Position Panel  
High-Density Distribution Solution (using 288-Termination/Splice panel)  
39  
35  
30  
25  
20  
2.1 m (7')  
CABLE TIE  
BRACKETS  
15  
10  
5
1
5" GUARD BOX  
660 mm  
(26")  
203 mm (8")  
457 mm (18")  
3.4 m (11' )  
aDC’s recommended fiber frame lineup uses four frames with 2 mm fiber  
jumpers to maintain the industry standard 2-inch patch cord pile-up  
The termination and splice LSX-288 solution utilizes a traditional frame designed to fit a variety of  
termination, splice and storage applications. This front load frame is built to ensure commonality with  
patch cord routing, slack storage and fiber protection. It is shipped complete with top and bottom  
troughs. Available accessories include interbay management panels (IMPs).  
O rd e r i n g I n f o r m a t i o n  
Description  
Dimensions (H x W x D)  
Catalog Number  
High-Density Frame (includes 8" deep front troughs)  
2.1 m x 660 mm x 381 mm  
(7' x 26" x 15")  
E-501-LGX-HD  
Frame Rear Guard Box  
(rear 2-inch bumper should be  
removed and replaced with this item)  
660 mm x 127 mm  
(26" x 5")  
RAC-0X0439  
Interbay Management Panel (includes 8" deep  
troughs and spools)  
2.1 m x 127 mm x 381 mm  
(7' x 5" x 15")  
E-501-L139-HD  
RAC-0X0440  
Interbay Management Panel Rear Guard Box  
(rear 2-inch bumper should be  
127 mm x 127 mm  
(5" x 5")  
removed and replaced with this item)  
288-Termination/Splice Distribution Panel  
279 mm x 584 mm x 381 mm  
(11" x 23" x 15")  
Refer to previous  
pages for catalog  
numbers  
End Guard  
2.1 m x 64 mm x 381 mm  
(7' x 2.5" x 15")  
RAC-7B0162  
Universal End Guard Extender  
2.1 m x 64 mm x 76 mm  
(7' x 2.5" x 3")  
E-501-12002  
w w w . a d c . c o m  
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  
1 - 8 0 0 - 3 6 6 - 3 8 9 1  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
High Density LSX 288-Position Panel  
Homerun Splitter Solution  
Parking Lot  
Plug and Play  
Splitters  
288-Termination  
Panels  
Parking Lot  
Plug and Play  
Splitters  
288-Termination  
Panels  
ADCs homerun splitter solution incorporates the LSX 288-position distribution panel along with plug  
and play splitter modules for central office splitting. Able to effectively manage 1,152 homes within  
a seven-foot frame, this solution offers excellent density with ADCs built-in cable management. In  
addition, these same plug and play splitter modules are commonly used within ADCs outdoor Fiber  
Distribution Hubs (FDHs), allowing for easy-to-manage inventory with one splitter type versatile enough  
for both inside and outside environments.  
O rd e r i n g I n f o r m a t i o n  
Description  
Dimensions (H x W x D)  
Catalog Number  
Network Rack with 2" WECO mounting spaces  
(shipped with 8-inch front guard box)  
2.14 m x 660 mm x 381 mm  
(7' x 26" x 15")  
RAC-7A0501  
Frame Rear Guard Box*; (rear 2-inch bumper should  
be removed and replaced with this item)  
660 mm x 127 mm  
(26" x 5")  
RAC-0X0439  
E-501-L139-HD  
RAC-0X0440  
Interbay Management Panel  
2.1 m x 127 mm x 381 mm  
(7' x 5" x 15")  
Interbay Management Panel Rear Guard Box*  
(rear 2-inch bumper should be removed and replaced  
with this item)  
127 mm x 127 mm  
(5" x 5")  
End Guard  
2.1 m x 64 mm x 381 mm  
(7' x 2.5" x 15")  
RAC-7B0162  
E-501-12002  
Universal End Guard Extender*  
288-Termination Distribution Panel  
2.1 m x 64 mm x 76 mm  
(7' x 2.5" x 3")  
279 mm x 584 mm x 305/381 mm Refer to previous pages  
(11" x 23" x 12/15")  
for catalog numbers  
Rack Mount Splitter Chassis – accommodates  
up to 24 plug and play splitters  
176 mm x 483/584 mm  
(7" x 19/23")  
FPS-MPPRACKMT24  
Cable Management for Rack Mount Splitter Chassis  
127 mm x 483/584 mm  
(5" x 19/23")  
FPS-MPPRACKMTCM  
ACE-ACC200-PKLT3  
FPS-MPP1AJJ  
Parking Lot Panel for Rack Mounts  
(accommodates three 1 x 32 splitter outputs)  
89 mm x 483/584 mm  
(3.5" x 19/23")  
1 x 32 Plug and Play Splitter Module Plug-in  
*used only when termination/splice panel is loaded into frame.  
Other configurations are available upon request. Please contact ADC Technical Assistance Center.  
w w w . a d c . c o m + 1 - 9 5 2 - 9 3 8 - 8 0 8 0 1 - 8 0 0 - 3 6 6 - 3 8 9 1  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
High Density LSX 288-Position Panel  
Outside Plant Controlled Environment Active Cabinet Solution  
active shelf  
(not included)  
Fiber management  
Tray (FmT)  
LSX 288-panel  
ADCs LSX-288 panels are also well suited to a controlled environment cabinet where limited rack space  
and high termination counts are necessary. Used in conjunction with ADCs Fiber Management Tray and  
RiserGuide1 on-demand cable management, this solution can meet both the termination demands, and  
cable management requirement for a future-proofed network.  
O rd e r i n g I n f o r m a t i o n  
Description  
Dimensions (H x W x D)  
Catalog Number  
288-Termination or Termination/Splice  
Distribution Panel  
279 mm x 584 mm x 305/381 mm Refer to previous pages for  
(11" x 23" x 12/15")  
catalog numbers  
FMT Bulk Storage Drawer  
44 mm x 584 mm x 305 mm  
(1.75" x 23" x 12")  
FMT-DBS000000-A00P2  
1 For more information on RiserGuide on-demand cable management, see ADC literature #101573AE.  
2 For more information on Fiber Management Trays (FMTs), see ADC literature #103743AE.  
w w w . a d c . c o m  
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  
1 - 8 0 0 - 3 6 6 - 3 8 9 1  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
From North America, Call Toll Free: 1-800-366-3891 • Outside of North America: +1-952-938-8080  
Fax: +1-952-917-3237 • For a listing of ADC’s global sales office locations, please refer to our website.  
ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101  
Specifications published here are current as of the date of publication of this document. Because we are continuously  
improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may  
verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc.  
views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features  
contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer  
106370ae 8/08 original  
©
2008 aDC Telecommunications, inc. all Rights Reserved  
Download from Www.Somanuals.com. All Manuals Search And Download.  

3Com Network Router 980 000077 002 User Manual
Acer Projector P3150 User Manual
Alliance Laundry Systems Clothes Dryer D310IE3B User Manual
AMX Switch FG2001 User Manual
ATN Binoculars NVG 7 User Manual
Axis Communications Security Camera M1004 W User Manual
BC Speakers Portable Speaker WG800 User Manual
Behringer Electronic Keyboard UMA25S User Manual
Behringer Music Pedal D0400 User Manual
Beko Refrigerator CDA543F User Manual