| GAS CONVECTION OVENS   DGC1, HGC40, HGC60,   HGC40D & HGC60D   GAS CONVECTION OVENS   MODELS   DGC1   HGC40   ML-43853   ML-43856   HGC40D ML-43859   HGC60 ML-114731   HGC60D ML-114732   701 S. RIDGE AVENUE   TROY, OHIO 45374-0001   FORM 19240 Rev. D (3-98)   TABLE OF CONTENTS   GENERAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4   INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4   Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4   Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4   Leveling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5   Installation Codes and Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5   Installing Basic Oven . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5   Assembling the Legs to the Oven . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6   Assembling the Chimney and Flue Extension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6   Assembling Stacked Ovens. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6   Assembling the Oven to the Stand . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7   Electrical Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8   Gas Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8   Testing the Gas Supply System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8   Burner Air Shutter Adjustments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9   Flue Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9   Before First Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9   OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10   Controls — Models DGC1 and HGC40/HGC60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10   Lighting the DGC1 and HGC40/HGC60 Ovens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11   Using the DGC1 and HGC40/HGC60 Ovens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11   Controls — Model HGC40D/HGC60D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12   Lighting the HGC40D/HGC60D Oven. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16   Using the HGC40D/HGC60D Oven . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16   Error Messages — HGC40D/HGC60D Oven . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17   Cook and Hold Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18   Proper Utensils. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19   Conserving Energy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19   Operating Hints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19   Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19   Cooking Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20   MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22   Replacing Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22   TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23   – 3 –   Installation, Operation and Care of   DGC1, HGC40 & HGC40D GAS CONVECTION OVENS   SAVE THESE INSTRUCTIONS FOR FUTURE USE   GENERAL   The Model DGC1 Oven is equipped with a mechanical thermostat and 1-hour dial timer; the Model   HGC40 and HGC60 Ovens are equipped with a solid state thermostat with probe and 1-hour dial   timer; and the Model HGC40D and HGC60D Ovens feature an electronic thermostat, electronic timer,   a cook-and-hold function and a pulse control. Each oven is equipped with five racks, a two-speed   1 ⁄ 2 H.P. blower motor and a 40,000 BTU/hr. burner as standard equipment, and requires a 120 volt   single phase electrical service. The doors open independently.   Models HGC60 and HGC60D have a deeper oven cavity.   A single oven is furnished with a set of four 253/4" (654mm) adjustable painted or stainless steel legs.   Stacked ovens are furnished with a set of four 8" (203mm) adjustable painted or stainless steel legs,   and a stacking kit for mounting one oven on top of the other.   A single oven installed on a storage stand is furnished with four 6" (152mm) adjustable painted or   stainless steel legs.   Additional racks are available as accessories. The porcelain interior is standard. A stainless steel   interior is available as an option.   INSTALLATION   UNPACKING   Immediately after unpacking the oven, check for possible shipping damage. If this oven is found to be   damaged, save the packaging material and contact the carrier within 15 days of delivery.   Prior to installation, verify that the electrical service and type of gas (natural or propane) agree with the   specifications on the oven data plate, located on the inside of the bottom front cover.   Do not use the doors or their handle to lift the oven.   LOCATION   The equipment area must be kept free and clear of combustibles. Maintain clearances from   combustible or non-combustible construction for at least 6" (152mm) from the side and 6" (152mm)   from the back of the oven. The installation location must allow adequate clearances for servicing and   proper operation.   The oven must be installed so that the flow of combustion and ventilation air will not be obstructed.   Adequate clearance for air openings into the combustion chamber must be provided. Make sure there   is an adequate supply of air in the room to allow for that required for combustion of gas at the oven   burners.   – 4 –   LEVELING   Ensure that the oven racks are level in the final installed position.   INSTALLATION CODES AND STANDARDS   Hobart ovens must be installed in accordance with:   In the United States   1. State and local codes.   2. National Fuel Gas Code ANSI-Z223.1 (latest edition), available from American Gas Association,   1515 Wilson Boulevard, Arlington, VA 22209.   3. ANSI/NFPA 96, "Vapor Removal from Cooking Equipment" (latest edition), available from National   Fire Protection Association, Batterymarch Park, Quincy, MA 02269.   4. National Electrical Code, ANSI/NFPA-70 (latest edition).   In Canada   1. Local codes.   2. CAN/CGA-B149.1, "Natural Gas Installation Code" (latest edition).   3. CAN/CGA-B149.2, "Propane Installation Code" (latest edition) available from the Canadian Gas   Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3.   4. Canadian Electrical Code, CSA Standard C22.2 No. 3 (latest edition).   INSTALLING BASIC OVEN   The basic oven must be installed on legs or be mounted on a modular stand. Installations on concrete   bases or other supports restricting air circulation underneath the oven is not advisable and may void   the warranty.   NOTICE: When the oven is mounted on casters, it must be installed with the casters supplied, a   connector (not supplied by Vulcan-Hart) complying with either ANSI Z21.69 (latest edition) or   CAN/CGA-6.16 (latest edition), and a quick-disconnect device complying with either ANSI Z21.41   (latest edition) or CAN1-6.9 (latest edition). It must also be installed with restraining means to guard   against transmission of strain to the connector, as specified in the appliance manufacturer’s instructions.   Attach the restraining device at the rear of the oven (Fig. 1).   CONNECT GAS   LINE STRAIN   RELIEF HERE   PL-51216   Fig. 1   – 5 –   ASSEMBLING THE LEGS TO THE OVEN   Unpack the oven and leg set.   Position oven on its back, taking care not to scratch or damage it. The gas pipe connection protrudes   beyond the back; provide for this when oven is tipped back by resting it on suitable spacers (2 x 4's etc.).   Attach each of the four leg assemblies to the bottom of the oven with the 24 bolts and lockwashers   (6 per leg).   Carefully raise the oven to its normal position. Turn the adjustable feet in or out to level the oven front-   to-back and side-to-side.   ASSEMBLING THE CHIMNEY AND FLUE EXTENSION   Remove the oven chimney and flue extension from the rear of the oven (motor compartment) and use   the screws provided to fasten the chimney to the top rear of the oven. The flanges on the chimney are   to be positioned under the top cover. Also attach the flue extension.   ASSEMBLING STACKED OVENS   Unpack the ovens and stack kit. Position one oven on its back for access to the oven bottom, taking   care not to scratch or damage it. The gas pipe protrudes beyond the back; provide for this when the   oven is tipped back by resting it on suitable spacers (2 x 4's, etc.). Attach the four leg assemblies with   the 24 bolts and lockwashers (6 per leg).   Place the lower oven (with legs) on the floor and remove the two 7/16" (11.1mm) diameter knockouts on   each side of the top cover.   Install the two locating studs (included in the leg stack set) into the screw plates on the underside of   the upper oven (Fig. 2).   Fig. 2   – 6 –   Move the oven with legs to the installed position and place the upper oven on top of the lower oven using   the locating studs.   Remove the rear panels from both ovens. Remove the right angle flue extension (Fig. 3) from the top   oven.   Insert the right angle short flue extension into the top oven. Install the long flue extension (Fig. 3) from   the stack kit over the right angle flue extension on the top oven. Insert the right angle of the long flue   extension into the bottom oven. Secure the flue extensions with the screws provided.   Install rear panels on both ovens. Install chimney (Fig. 3) on upper oven. Connect the piping between   the top oven and bottom oven. Pipe compound must be suitable for the type of gas being used (natural   or propane).   The manual gas valve at the bottom of the control panel should remain off until all electrical connections   are made and the ovens are checked or used.   Fig. 3   ASSEMBLING THE OVEN TO THE STAND   Unpack the oven and stand. Position oven on its back, taking care not to scratch or damage it. The   gas pipe connection protrudes beyond the back; provide for this when the oven is tipped back by resting   it on suitable spacers (2 x 4's, etc.).   Install the two locating studs (included in the stand carton) into the screw plates on the underside of   the oven (see Fig. 2).   Attach each of the four leg assemblies to the bottom of the stand with the 24 bolts and lockwashers   (6 per leg).   Mount the oven on top of the stand.   – 7 –   ELECTRICAL CONNECTIONS   WARNING: THE POWER CORD IS PROVIDED WITH A GROUNDING PLUG. THE OUTLET TO   WHICH THIS PLUG IS CONNECTED MUST BE PROPERLY GROUNDED. IF THE RECEPTACLE IS   NOT THE PROPER GROUNDING TYPE, CONTACT AN ELECTRICIAN. DO NOT REMOVE THE   GROUNDING PRONG FROM THIS PLUG.   Your gas convection oven is equipped with a 120 volt / 60 Hz. / 1 phase cord and plug and requires   only that it be plugged into a properly grounded 120 volt receptacle.   A wiring diagram is located on the inside of the right side panel.   GAS AND ELECTRICAL DATA   GAS DATA   ELECTRICAL DATA   AMP/LINE   120 Volts   MODEL   INPUT BTU/HR   MANIFOLD PRESSURE   Natural   Propane   40,000   40,000   40,000   Natural   Propane   DGC1   40,000   40,000   40,000   3.5" W.C. (0.8 kPa)   3.5" W.C. (0.8 kPa)   3.5" W.C. (0.8 kPa)   10" W.C. (2.5 kPa)   10" W.C. (2.5 kPa)   10" W.C. (2.5 kPa)   10 Amps   HGC40/HGC60   HGC40D/HGC60D   10 Amps   10 Amps   Stacked ovens require double BTU/Hr and double amperage.   GAS CONNECTIONS   Gas supply connections and pipe joint compound must be suitable for sealing piping for propane or   natural gases.   The oven is provided with a regulator integral to the gas solenoid valve and requires no external   regulator.   The manual gas shutoff valve is located at the bottom of the front control panel.   The oven should be connected to the gas line after leveling. The gas supply line must be at least the   equivalent of 3/4" (19mm) iron pipe. Make sure piping is clean and free of obstructions, dirt or pipe joint   compound.   WARNING: PRIOR TO LIGHTING, CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS.   USE SOAP AND WATER SOLUTION. DO NOT USE AN OPEN FLAME.   TESTING THE GAS SUPPLY SYSTEM   The oven and its individual shutoff valve must be disconnected from the gas supply piping system   during any pressure testing of that system at test pressures greater than 1/2 psig (3.45 kPa).   The oven must be isolated from the gas supply piping system by closing the manual shutoff valve during   pressure testing of the gas supply piping system at test pressures equal to or less than1/2 psig (3.45 kPa).   – 8 –   Gas Pressures and Orifices   Natural Gas   The burner orifices are sized to deliver the nameplate input rating (40,000 Btu/hr) at a gas manifold   pressure of 3.5" W.C (0.8 kPa). The gas pressure regulator is integral to the gas solenoid valve   and is factory set to supply 3.5" W.C. (0.8 kPa) as required for natural gas.   Propane Gas   The burner orifices are sized to deliver the nameplate input rating (40,000 Btu/hr) at a gas manifold   pressure of 10" W.C (2.5 kPa). The gas pressure regulator is integral to the gas solenoid valve and   is factory set to supply 10" W.C. (2.5 kPa) as required for propane gas.   BURNER AIR SHUTTER ADJUSTMENTS   The HGC40D oven burner has fixed, factory-adjusted air openings and requires no field adjustment.   FLUE CONNECTIONS   Ventilation requirements will vary with each installation and must comply with applicable portions of   NFPA Standard #96, "Vapor Removal from Cooking Equipment," and with local codes. Keep in mind   that:   The oven should be located under a hood which has an adequate connection to an exhaust duct   and extends 6" (152.4mm) beyond the oven sides.   Clearance above the oven flue should be adequate for the flue products to escape so that there is   no interference with the heat circulation in the ovens.   Ovens may use an optional down draft diverter flue method. This optional down draft diverter must   be purchased from the oven manufacturer and vented to the outside; otherwise, the installation of   any such device will void all oven certifications and warranties. When the diverter is supplied, it   may be connected to a Type “B” vent.   BEFORE FIRST USE   Before using the oven for the first time, it must be "burned in" to release any odors that might result from   heating the new surfaces in the chamber.   Using a clean damp cloth, wipe the inside of the oven, including the racks.   Close the oven doors, turn the ON/OFF/COOLDOWN switch ON, turn the thermostat to   300°F (149°C) and allow the oven to cycle for 6 to 8 hours before turning the switch OFF.   – 9 –   OPERATION   CONTROLS — MODELS DGC1 & HGC40/HGC60 (Fig. 4)   ON/OFF/COOL   DOWN SWITCH   ON/OFF/COOL   DOWN SWITCH   POWER   ON   POWER   ON   OFF   OFF   COOL DOWN   COOL DOWN   FAN SWITCH   FAN SWITCH   HI   HI   LIGHT SWITCH   LIGHT SWITCH   FAN   ON   FAN   ON   LO   LIGHTS   LO   LIGHTS   OFF   OFF   ON LIGHT   ON LIGHT   ON   ON   HEAT   HEAT   IGNITION   HEAT LIGHT   IGNITION   HEAT LIGHT   COOK TEMPERATURE   COOK TEMPERATURE   OFF   NO IGNITION LIGHT   500   475   NO IGNITION LIGHT   F 500   150   450   40 350   450   225   250   300   42 40 250   THERMOSTAT   300   350   300   THERMOSTAT   COOK TIME   0 COOK TIME   60   55   50   45   5 TIMER   10   15   20   0 60   5 TIMER   55   50   45   10   15   4 35   25   OVE3N0   TO LIGHT   PLACE ON/OFF/COOL DOWN   SWITCH IN "ON" POSITION.   20   40   35   30   25   IF OVEN FAILS TO LIGHT   RETURN ON/OFF/COOL DOWN   SWITCH TO "OFF". ALLOW   5 MINUTES FOR RETRIAL.   TO LIGHT OVEN   PLACE ON/OFF/COOL DOWN   SWITCH IN "ON" POSITION.   TO SHUT-OFF OVEN   PLACE ON/OFF/COOL DOWN   SWITCH IN "OFF" POSITION.   TO SHUT-OFF OVEN   PLACE ON/OFF/COOL DOWN   SWITCH IN "OFF" POSITION.   ON   ON   OFF   GAS VALVE   OFF   GAS VALVE   GAS VALVE   GAS VALVE   PL-51602   PL-51603   MODEL DGC1   MODEL HGC40/HGC60   Fig. 4   ON / OFF / COOLDOWN SWITCH — ON — turns oven control circuits on.   OFF — turns oven control circuits off.   COOLDOWN — allows the fan motor to run with the doors   ajar to speed oven cooling.   2-SPEED FAN SWITCH — HI / LO — Adjusts air velocity in the oven.   LIGHT SWITCH — ON / OFF   THERMOSTAT   — Turns lights in the oven on or off.   — Controls oven temperature during cooking operation.   TIMER   — Use to set cooking cycle time. Alarm sounds continuously   when elapsed time counts down to 0; oven does not turn off.   Turn timer to OFF position to stop alarm. When oven is not   in use, keep timer at OFF position.   ON LIGHT (Amber)   — Lit when the ON/OFF/COOLDOWN switch is positioned at   ON or COOLDOWN.   HEAT LIGHT (White)   — Comes on and goes off when the burner cycles on and off.   NO IGNITION LIGHT (Red)   — Comes on if burner fails to ignite after the third try. When   lighting oven, the NO IGNITION LIGHT cycles ON during   the 5-second purge and OFF during 7-second ignition trial.   GAS VALVE   — When ON, allows gas to flow to the ignition system.   – 10 –   LIGHTING THE DGC1 AND HGC40/HGC60 OVENS   Turn manual gas valve ON. Turn ON/OFF/COOLDOWN switch ON and turn thermostat to its maximum   setting. Both the ON and HEAT lights should come on. If HEAT light is not on, make sure door is closed.   After 5 seconds, the spark ignition system will start and the solenoid valve will open, allowing gas to   flow to the burner for 7 seconds. This 5-second purge and 7-second ignition trial will repeat up to two   more times if the burner does not light within the first 7-second ignition trial. During this 5-second   prepurge, the red NO IGNITION light will be lit.   When the burner gas ignites, a slight "roar" will be heard. This "roar" is a normal condition of the power   burner and will become almost undetectable in the normal operating mode after warm-up. The NO   IGNITION light will go off when ignition occurs.   If the burner fails to light after three trials, the red NO IGNITION light will be lit and remain on. Turn   ON/OFF/COOLDOWN switch OFF for five minutes before repeating lighting sequence previously   described.   If the burner does not light after three trials, turn off the manual gas valve and call a qualified servicer.   USING THE DGC1 AND HGC40/HGC60 OVENS   Preheating   1. Turn ON/OFF/COOLDOWN switch ON. The amber ON light will come on, indicating that power to   the oven is on.   2. Set THERMOSTAT as desired. Refer to COOKING GUIDELINES for suggested temperatures and   times for various products.   3. Prepare product and place in suitable pans. When the white HEAT light goes off, the oven has   reached desired preheat temperature.   Cooking   1. Open doors and load the product into the oven. Place pans in the center of the racks. Close doors.   2. Set the TIMER. After the preset time lapses, turn timer to OFF position to stop the buzzer.   4. When product is done, open doors and carefully remove cooked product from the oven. Wipe up   any spills.   End of Day   • • • • Turn THERMOSTAT to OFF.   Turn ON/OFF/COOLDOWN switch to COOLDOWN.   Leave door ajar while the fan is on to cool the oven.   When oven has cooled sufficiently, turn ON/OFF/COOLDOWN switch to OFF and clean oven.   – 11 –   CONTROLS — MODEL HGC40D/HGC60D (Fig. 5)   T E MPE   R A T UR   THERMOSTAT   TIMER   E HE   A T RE   A D Y CO   O K HO   L D TIM   E CO   O K ST   A O R T ST   P PU   L S E 2 SPEED FAN - HI / LO   LIGHT SWITCH   FA   N S P E E D LI   G H T S HI   ON   LO   W OF   F PO   W E R ON / OFF / COOL DOWN   SWITCH   ON   OF   F CO   DO   O L N W TO LIGHT OVEN   TURN GAS VALVE "ON"   PUSH MASTER SWITCH TO   "ON" POSTION. IF OVEN   FAILS TO LIGHT. PUSH   MASTER SWITCH TO "OFF"   TURN GAS VALVE OFF WAIT   5 MINUTES FOR RETRIAL.   TO SHUT- OVEN OFF   PLACE MASTER SWITCH IN   "OFF" POSTION TURN GAS   VALVE OFF   ON   OFF   GAS VALVE   GAS VALVE   PL-51601   MODEL HGC40D/HGC60D   Fig. 5   THERMOSTAT CONTROL   Temperature Display (When Not Timing Product)   Displays set cook temperature while the light in the Cook Button is lit. Will be overridden   to display actual cavity temperature for 8 seconds when Thermometer Button is pushed.   1. The light in the Thermometer Button will be lit while the actual temperature   is being displayed.   2. The light in the Thermometer Button will extinguish when the display returns   to set temperature display.   Temperature Display (When Timing Product)   Displays set hold temperature while the light in the Hold button is lit. Displays the cook   temperature when the Cook button is lit. Will be overridden to display actual cavity   temperature for 8 seconds when the Thermometer Button is pushed.   1. The light in the Thermometer Button will be lit while actual temperature is   being displayed.   2. The light in the Thermometer Button will extinguish when the display returns   to set temperature display.   – 12 –   Temperature Knob (When Not Timing Product)   1. Sets the cook temperature when the Cook Button light is lit. The Cook Button   light can be turned on by pressing the Cook Button.   2. Sets the hold temperature when the Hold Button light is lit. The Hold Button   light can be turned on by pressing the Hold Button.   Temperature Knob (When Timing Product)   1. Sets the cook temperature when the Cook Button light is lit. The Cook Button   light cannot be changed by pressing the Cook Button.   2. Sets the hold temperature when the Hold Button light is lit. The Hold Button   light cannot be changed by pressing the Hold Button.   Cook Button Light (If On) - (While Not Timing Product)   Indicates the cook mode is selected. This means:   1. The displayed temperature settings will be for the cook temperature except   for the time that the light in the Thermometer Button is lit.   2. Rotating the Thermostat Knob will change the cook set temperature.   3. Cook time can be adjusted using the Timer Knob.   4. The time displayed is the initial set cook time.   5. It is possible to select the Hold mode using the Hold Button.   Cook Button Light (If On) - (While Timing Product)   Indicates the cook mode is selected. This means:   1. The displayed temperature settings will be for the cook temperature except   for the time that the light in the Thermometer Button is lit.   2. Rotating the Temperature Knob will change the cook set temperature.   3. It is not possible to select the Hold mode using the Hold Button.   4. The time displayed is the time counted down from the initial cook time set.   Cook Button   1. Lights the Cook Button light. See Cook Button Light above.   2. Selects the Cook mode.   3. Has no effect if timing in the Hold mode.   – 13 –   Thermometer Button   When pressed, causes actual cavity temperature to display for about 8 seconds, then   display returns to set temperature.   Heat Light   When lit, indicates that power is being supplied to the burner.   Ready Light   Will be lit any time the actual temperature is within +/- 5°F (+/- 2.7°C) of the set temperature   for the current mode.   TIMER CONTROL   Time Display (While Not Timing Product)   Displays the set cook time if the light in the Cook Button is lit.   Time Display (While Timing Product)   1. Displays the counted down cook time if the Cook Button light is lit and in the   Cook mode.   2. Displays the counted up hold time if the Hold Button light is lit and in the   Hold mode. Count-up of hold time does not begin until cavity temperature   reaches the hold temperature.   Time Display Semicolon   1. Flashing if product is timing.   2. Not flashing if not timing product.   Time Button   Press to set cooking cycle time.   Time Button Light   Illuminates when the Time Button is pressed.   Timer Knob   Sets the cook time when not already timing and the Cook Time indicator is lit.   – 14 –   Pulse Button   Selects the pulse time setting. A cook time must be set first. The pulse time can then   be set equal to or less than the cook time. The pulse time will be the portion of cook time   to operate in the pulse mode. Pulse mode will start first. When pulse time elapses, the   remainder of the cook time will be in the non-pulse mode.   Use when cooking delicate product, such as strudel, muffins, cupcakes, meringue pies,   etc., to keep product from forming "waves" on the top.   Use the Pulse Button to switch between the selection of pulse mode and no pulse mode   time setting. A pulse mode time of zero means no pulse mode will occur.   The light in the Pulse Button will be lit when in the pulse mode.   In Pulse Mode:   1. The fan cycles (45 seconds ON and 45 seconds OFF) for the duration of the   pulse cycle time.   2. The fan stays on while the heat cycles in hold mode.   3. The fan stays on while heat cycles at 100% power when not timing.   4. Can be switched at any time.   Stop/Start Button   1. Initiates timing a product in the mode selected if a cook time has been set.   2. Stops timing of a product if a timing sequence has already started.   Hold Button   Selects Hold mode.   1. Allows selection of hold temperature.   2. Temperature indication of ---°F (---°C) indicates no hold mode.   Hold Button Light   Is lit when in the Hold mode.   1. When not timing, allows setting/enabling a hold mode setting of ---°F   (---°C), meaning no hold will take effect.   2. Any other temperature means that when the actual cook time has ended, the   oven will enter the Hold mode and use the hold temperature.   – 15 –   TWO-SPEED FAN SWITCH   Adjusts air velocity in the oven.   LIGHT SWITCH   Turns lights in the oven on or off.   ON / OFF / COOLDOWN SWITCH   1. ON turns oven control circuits on.   2. OFF turns oven control circuits off.   3. OVEN COOL allows the fan motor to run with the doors ajar to speed oven   cooling.   GAS VALVE   When ON, allows gas to flow to the ignition system.   LIGHTING THE HGC40D/HGC60D OVEN   1. Turn manual Gas Valve ON.   2. Push ON/OFF/COOLDOWN Switch to the ON position and set THERMOSTAT to its maximum   setting. The HEAT light should come on. If HEAT light is not on, make sure the door is closed.   3. If the oven fails to light, push ON/OFF/COOLDOWN Switch to the OFF position. Wait 5 minutes   before trying to relight the oven.   USING THE HGC40D/HGC60D OVEN   Preheating   1. Push ON/OFF/COOLDOWN Switch to ON position. The HEAT light will come on, indicating that   power to the oven is on.   2. Set THERMOSTAT as desired. Refer to COOKING GUIDELINES for suggested temperatures and   times for various products.   3. Prepare product and place in suitable pans. When READY light comes on, oven has reached   desired preheat temperature.   – 16 –   Cooking   1. Open doors and load the product into the oven. Place pans in the center of the racks. Close doors.   2. Set COOK temperature and TIME. Set HOLD temperature and PULSE time, if desired. PULSE   time may not be more than COOK time. PULSE will cycle the fan during the set time at the beginning   of the cook cycle.   3. Press the START/STOP Button to start the cooking cycle.   4. At the end of the cooking cycle, the buzzer will sound continuously if the HOLD mode is OFF. If   the HOLD mode is ON, there will be a short beep at the beginning of Second Stage Cooking (oven   temperature will begin to decline to the HOLD temperature), and a long beep (20 seconds) at the   end of the cooking cycle. (See COOK AND HOLD OPERATION.)   5. When product is done, open doors and carefully remove cooked product from the oven. Wipe up   any spills.   End of Day   1. Push ON/OFF/COOLDOWN Switch to COOLDOWN. Leave door ajar while the fan is on to cool   the oven.   2. When the oven has cooled sufficiently, push the ON/OFF/COOLDOWN Switch to the OFF position   and clean the oven.   ERROR MESSAGES — HGC40D/HGC60D OVEN   E-01 High limit error. Contact your local Hobart Service Office.   E-02 Low limit error. Contact your local Hobart Service Office.   E-03 High ambient temperature (215°F/101.7°C). Contact your local Hobart Service Office.   E-04 Low ambient temperature (32°F/0°C). Let control warm up after cold storage.   E-05 Ignition failure. After trying ignition three times, contact your local Hobart Service Office.   E-06 Thermocouple probe open. Contact your local Hobart Service Office.   When calling for service, please advise what error code was displayed.   – 17 –   COOK AND HOLD OPERATION   Cook and Hold cooks the product in two stages. During First Stage Cooking, the oven temperature is   regulated by the Cook thermostat for the amount of time set on the Cook Timer. After the lapsed time   counts down to 00:00, Second Stage Cooking begins. During Second Stage Cooking, the burners are   off as the temperature in the oven declines to the Hold Temperature. The doors should remain closed   during Second Stage Cooking.   When the Hold temperature is reached, cooking is done. The Time Display counts up the Hold time   and flashes "Hold." Temperature in the oven will be maintained at the Hold temperature until the oven   is turned off.   COOK AND HOLD DIAGRAM - Time vs. Temperature   OVEN TEMPERATURE   SHORT BEEP.   400ºF   300ºF   200ºF   100ºF   TIMER DISPLAY COUNTS DOWN,   COLON FLASHES.   TIMER DISPLAY FLASHES 00:00.   COOK THERMOSTAT OFF.   BURNERS OFF UNTIL HOLD   TEMPERATURE IS REACHED.   COOKING FROM   STORED HEAT   LONG BEEP (20 SEC.)   BURNERS MAINTAIN   HOLD TEMPERATURE.   TIMER DISPLAY COUNTS UP   HOLD TIME AND FLASHES   "HOLD."   LOAD PRODUCT   INTO OVEN   PRODUCT TEMPERATURE   TEMP.   PREHEAT   FIRST STAGE COOKING   SECOND STAGE   HOLDING   COOKING   (DO NOT OPEN   DOORS)   TIME   PL-51608   – 18 –   PROPER UTENSILS   The use of proper utensils can enhance oven operation. Medium and light weight pans allow the   product to warm faster. Roast meats in shallow pans deep enough to hold all juices yet allow free air   circulation.   CONSERVING ENERGY   • • • • • • • Turn off unused equipment.   Adjust menu patterns and cooking/baking schedules for optimum equipment use.   Reduce thermostat settings in slack periods since gas equipment heats up and recovers quickly.   Preheat only to required cooking temperature for specific food — not higher.   Do not open the oven door unless absolutely necessary.   Keep area around the oven door clean and free of food particles.   Any obstruction that prevents the door from closing completely will adversely affect oven efficiency.   OPERATING HINTS   When using the convection oven for the first time with a particular food, check the degree of doneness   periodically before the suggested time has elapsed, to make sure the desired doneness is achieved.   Record your temperature and time settings for various products. The convection oven can provide   consistent, repeatable results.   The convection oven is a bit faster than conventional deck-type ovens; temperature settings are lower   and cook times are shorter. Since recipes and foods are subject to many variations and tastes, the   guidelines regarding Times and Temperatures in this manual are SUGGESTIONS ONLY. Experiment   with your food products to determine the cooking temperatures and times that give you the best results.   CLEANING   WARNING: TURN OVEN OFF AND UNPLUG ELECTRICAL CORD BEFORE CLEANING.   Clean outside of the oven daily by wiping with a clean damp cloth.   Clean porcelain oven interior daily with soap or detergent and water. Rinse thoroughly and wipe dry   with a soft clean cloth.   Optional Stainless Steel Oven Interior   Soap or detergent and water usually handle routine cleaning. Rinse thoroughly, dry with a soft clean   cloth.   For burned-on foods and grease which resist simple soap and water cleaning, an abrasive cleanser   (scouring powder) mixed into a paste may be used. Apply with stainless steel wool or sponge, always   rubbing with the "grain."   This treatment is equally effective for "heat tint" (slightly darkened areas caused by oxidation). Again,   remember to rub in the direction of the polish lines. Rinse with clear water and dry with a soft cloth.   – 19 –   . COOKING CHARTS   Models DGC1, HGC40/HGC40D and HGC60/HGC60D   BAKED PRODUCTS   Product   Temps.   (°C)   Time (Min.) No. Shelves   Fan Speed   (°F)   300   325   325   300   300   325   325   325   300   275   350   350   300   350   275   325   325   Sheet Cakes (5 lb. [2.3 kg] each)   Soda Biscuits   (149)   (163)   (163)   (149)   (149)   (163)   (163)   (163)   (149)   (135)   (177)   (177)   (149)   (177)   (135)   (163)   (163)   30   12   5 5 5 5 3 5 5 5 5 5 5 5 5 5 5 5 5 Low   Low   Low   Low   Low   Low   Low   Low   Low   Low   Low   Low   Low   High   High   High   High   Yeast Rolls   15-20   15   Corn Bread   Gingerbread   18   Chocolate Cake   Chocolate Chip Cookies   Sugar Cookies   Yellow Cake   20   10   12   25   Angel Food Cake   Brownies   25   15-20   20-25   25-30   30   Apple Turnovers   Cream Puffs   Apple Pie (Fresh)   Pumpkin Pie   40   Berry Pies (Frozen)   Fruit Pie (Frozen)   40   45   Pizza (Individual), Frozen   Precooked Crust)   310-325 (154-163)   8-13   5 Low/High*   Bread (1 lb. loaf) (454 gr.)   Brown and Serve Rolls   Coffee Cake   340   350   300   325   375   325   350   325   (171)   (177)   (149)   (163)   (190)   (163)   (177)   (163)   30   15   3 5 3 5 5 5 5 5 High/Low**   Low   45   High   Pineapple Upside Down Cake   Fruit Cobbler   30   High   25   High   Danish Pastry   12-15   12   Low   Pie Shells   Low   Cinnamon Buns   15-20   Low   * **   Some people prefer high speed for darker cheese.   Low speed will give you a more uniform color.   – 20 –   MEAT & FISH PRODUCTS   Product   Temps.   Time (Min.) No. Shelves   Fan Speed   (°F)   250   275   275   300   375   275   325   400   375   (°C)   Prime Rib (20 lb. rare) (9.1 kg)   Rolled Roast Beef   (121)   (135)   (135)   (149)   (190)   (135)   (163)   (204)   (190)   23⁄4 Hr.   21⁄2 Hr.   21⁄2 Hr.   25-30   12   2 2 2 3 5 1 3 5 5 5 5 High   High   High   High   High   High   High   High   High   High   High   Veal Roast Boned (15 lb.) (6.8 kg)   Stuffed Pork Chops   Lamb Chops   Steamship Round (80 lb.) (36.3 kg)   Meatloaf   23⁄4 Hr.   40   Hamburger Patties (4 oz.) (113 gr.)   Meat Pot Pies   8-10   40   Chicken Parts   300-325 (149-163)   350 (177)   30-40   18   Fish Sticks   MISCELLANEOUS PRODUCTS   Product   Temps.   Time (Min.) No. Shelves   Fan Speed   (°F)   350   375   450   450   350   325   250   (°C)   Macaroni & Cheese   (177)   (190)   (232)   (232)   (177)   (163)   (121)   30   10   45   55   20   35   90   3 5 5 5 5 5 3 High   Low   Cheese Sandwiches   Baked Potatoes (6-8 oz.)(170-227 gr.)   Baked Potatoes (10 oz.) (283 gr.)   Stuffed Peppers   High   High   High   High   High   Scalloped Potatoes   Lasagna   FOR BEST RESULTS   Product to be cooked should be centered on the oven rack, and the racks should be spaced evenly within the   oven cavity.   It is best not to rotate the product or open the doors during the cooking cycle.   Preheat oven to 50°F (10°C) higher than desired cooking temperature. After the oven is loaded, close the door   and set thermostat to desired cooking temperature.   Make adjustments in the time, temperature and fan speed settings until the desired results are obtained. Adjust   only one setting at a time. For example, if the product is too dark on the outside and not done on the inside, it   is cooking too fast. Try reducing the temperature by 25°F (-3.9°C).   These cooking charts will be helpful in arriving at time, temperature and fan speed settings for products commonly   cooked in convection ovens, but since each user’s perception of how a particular product should be finished   will be different, it may be necessary to make adjustments in the settings until the desired results are obtained.   When the desired results are obtained, make a note of the settings used for a particular recipe and product   load. For example, if the user typically bakes four 18" x 26" (45.7cm x 66cm) sheet cakes using 5 lb. (2.26 kg)   of batter for each cake, that would constitute a typical product load for that recipe. If the size of the load is   changed, it may affect the final results. If the user changes either the weight of the cakes being baked, or the   number of cakes being baked at a time, it may be necessary to make further adjustments in the time or   temperature settings to achieve the desired results.   – 21 –   MAINTENANCE   WARNING: TURN OVEN OFF AND UNPLUG ELECTRICAL CORD BEFORE PERFORMING ANY   MAINTENANCE.   The fan motor comes with sealed bearings and requires no lubrication.   The door mechanism requires occasional lubrication with mineral oil.   If this oven is placed on casters, it should be connected to the supply piping with the proper disconnect   device and restraint. If it is necessary to disconnect the restraint, first turn off the gas supply.   Reconnect the restraint before turning the gas supply on and returning the oven to its original   installation position.   Annually check the flue, when cool, to be sure it is free of obstructions.   REPLACING LAMPS   • • • • • Remove all racks by pulling forward, lifting up and out.   Remove the right rack support by lifting up.   Unscrew glass dome(s) from light body.   Replace the bulb(s).   Reassemble glass dome(s), rack support and racks by reversing the disassembly procedure.   – 22 –   TROUBLESHOOTING   If NO IGNITION LIGHT remains lit for more than 20 seconds after three trials (Models DGC1 and   HGC40), or E-05 displays after three trials (Model HGC40D):   • • • Turn oven off for 5 minutes before attempting to relight.   Check gas supply valves to be sure they are open.   Check electrical power source and connections.   Contact personnel qualified to install and repair gas equipment for any other service problems.   – 23 –   NOTES   FORM 19240 Rev. D (3-98)   PRINTED IN U.S.A.   – 24 –   |