| Ver.1.00   F&eIT Series   Isolated Digital I/O Module   DIO-4/4(FIT)GY   This product is an expansion module (device module) that adds   digital signal I/O interfaces to one of various types of controllers.   The product is used in combination with the I/O controller   module <CPU-CAxx(FIT)GY> (*1) or microcontroller unit   <CPU-SBxx(FIT)GY> (*1) in the F&eIT Series.   This product can perform a maximum of 4 points of   Optocoupler isolated input and 4 points of Optocoupler isolated   output per module. (Input: 12 - 24 VDC specified, output: 12 -   48 VDC specified)   *1 This module is available in different product models. "x" in each model number   represents a blank or one alphanumeric character. This is applicable to the rest of this   document.   * Specifications, color and design of the products are subject to   change without notice.   Features   Specification   This product can perform 4-point digital signal input and 4-point   digital signal output, treating 4 points as a group.   Specifications   Specifications   DIO-4/4(FIT)GY   Item   Input section   Input format   Input section is ready to accept both the current sinking output   and current source output.   Optocoupler isolated input   (compatible with current sink output and current source   output)   Input resistance   Input ON current   Input OFF current   3kΩ   3.4mA or more   0.16mA or less   The output section is a high sink current, open collector type   using high-capacitance transistors.   150 mA/24 VDC or 50 mA/48 VDC max. (per channel)   Number of input signal points 4 points (4 points/common)   Response time Within 1msec   External circuit power supply 12 - 24VDC (±15%)   (4mA/12V - 8mA/24V per channel)   Isolated I/O operations using an optocoupler improves noise   immunity.   Output section   Output format   Optocoupler isolated open collector output (current sink type)   12 - 48VDC (±15%)   150mA (12 - 24V) (per channel) (Max.)   50mA (36 - 48V) (per channel) (Max.)   4 points (4 points/common)   Ratings   Output voltage   Output current   A rotary switch allows you to set device IDs, making it easy to   keep track of device numbers.   Number of output signal   points   Like other F&eIT series products, the module has a 35mm DIN   rail mounting mechanism as standard. A connection to a   controller module can be effected on a lateral, stack basis in a   unique configuration, which permits a simple, smart system   configuration without the need for a backplane board.   Response time   Within 1msec   External circuit power supply 12 - 48VDC (±15%)   Common section   Interrupt level   Using CPU-SBxx(FIT)GY: IRQ 5, 7, or 9   Internal current consumption 5VDC(±5%) 150mA(Max.) *1   Allowable distance of signal Approx. 50m (depending on wiring environment)   extension   Physical dimensions (mm)   Weight of the module itself   Module connection method   25.2(W) x 64.7(D) x 94.0(H) (exclusive of protrusions)   100g   Stack connection by means of a connection mechanism   standard with the system.   Module installation method   One-touch connection to 35mm DIN rails   (standard connection mechanism provided in the system)   AWG 28 - 16 wire type: 0.32 - 1.30mm   FRONT-MC 1,5/12-STF-3,81 (made by Phoenix Contact   Corp.)   Applicable wire   Applicable plug   3.81mm-pitch, rated current: 8A (Max.)   *1 The stack connector accepts currents of up to 3.0A (Max.).   Installation Environment Requirements   Packing List   Item   Requirement description   Operating temperature   Storage temperature   Operating humidity   Floating dust particles   Corrosive gases   0 - 50°C   -10 - 60°C   10 - 90%RH (No condensation)   Not to be excessive   None   Module[DIO-4/4(FIT)GY] …1   First step guide … 1   CD-ROM [F&eIT Series Setup Disk] *1…1   Interface connector plug…1   Noise immunity Line-noise AC line/2kV, Signal line/1kV   *1   (IEC1000-4-4Level 3, EN61000-4-4Level 3)   Static   electricity   Contact discharge/4kV (IEC1000-4-2Level 2,   EN61000-4-2Level 2)   *1 The CD-ROM contains various software and User’s Guide.   resistance Atmospheric discharge/8kV (IEC1000-4-2Level 3,   EN61000-4-2Level 3)   Vibration   Sweep   10 - 57Hz/semi-amplitude 0.15mm, 57 - 150Hz/2.0G   resistance   resistance 80minutes each in X, Y, and Z directions   (JIS C0040-compliant, IEC68-2-6-compliant)   Impact resistance   15G half-sine shock for 11ms in X, Y, and Z directions   (JIS C0041-compliant, IEC68-2-27-compliant)   *1 When using a POW-AD22GY   DIO-4/4(FIT)GY   1 Ver.1.00   Example of a Connection to Current Sink Output   Interface Connector   Module   External circuit   Vcc   How to Connect an Interface Connector   When connecting the Module to an external device, you can   use the supplied connector plug.   3kΩ   Minus   External   power supply   12V - 24VDC   common   To wire the Module, strip the sheath about 9 - 10mm from an   end of the wire and insert the exposed wire into an opening.   Tighten the screw to fasten the inserted wire. Applicable   wires are AWG28 - 16.   Input   pin   Current sink   output   Optocoupler   X Turn the screw to fasten the wire.   0 4 1 5 2 3 7 6 6 Example of a Connection to Current Source Output   9 - 10mm   Device   ID   2 Module   External circuit   COM 0   NC   0 Vcc   - Applicable wire:   1 3.81mm pitch, 12-pin type, 8.0A rated current   3kΩ   2 3 MC1, 5/12-GF-3.81 [made by Phoenix Contact Corp.]   COM1   Minus   X NC   External   common   power supply   4 5 6 7 - Applicable plug:   Input   pin   Front screw type with connector stopper flange   FRONT-MC 1,5/12-STF-3,81 [made by Phoenix Contact Corp.]   Applicable cable: AWG28-16   Optocoupler   Current   source output   DI-8   CAUTION   Removing the connector plug by grasping the cable can   break the wire.   Output section   Figure below shows the output circuit for the interface section   of this product. The signal output section consists of an   Optocoupler isolated open collector output (current sink type).   An external power supply is therefore required to drive the   output section of this module.   The maximum output current rating per channel is 150 mA for   this product (at 12 - 24 VDC) or 50mA for this product (at 36 -   48 VDC). A surge voltage protection circuit (zener diode) is   provided for the output transistors of this module. When the   module drives relays, lamps, and other induction loads,   however, another surge voltage countermeasure should be   provided on the load side.   Signal Layout on the Interface Connector   The Module can be connected to an external device using a   12-pin connector that is provided on the Module face.   Input port   plus / minus common   COM 0 --- +/-COM   N.C.   X 0 --- IN 0   X 1 --- IN 1   Digital Input: 4points   X 2 --- IN 2   X 3 --- IN 3   COM 1 --- +COM   COM 2 --- -COM   Y 0 --- OUT 0   Output port plus common   Output port minus common   CAUTION   Y 1 --- OUT 1   Digital Output: 4points   When the power is turned on, all output will be OFF.   Y 2 --- OUT 2   Y 3 --- OUT 3   Output Circuit   Module   External circuit   External I/O Circuits   Vcc   Plus   common   Load   Input section   Output   pin   Figure below shows the input equivalent circuit for the interface   section of this product.   External   power supply   12V - 48VDC   The signal input section consists of an Optocoupler isolated   input (compatible with both current sink output and current   Vcc   source output).   An external power supply is therefore   required to drive the input section of this module. The power   requirement for the <DIO-4/4(FIT)GY> or <DI-8(FIT)GY> is   about 8 mA per input channel at 24 VDC (about 4 mA at 12   VDC).   Load   Output   pin   Optocoupler   Minus   common   Input Circuit   Module   External circuit   Vcc   3kΩ   Connection example:   Using Inputs X0   +/-   common   External   power supply   12V - 24VDC   Input   pin   Input contact   Optocoupler   Input plus common (e.g., connector COM0)   point   + External   power supply   12V - 24VDC   - Input pin (e.g., connector X0)   3kΩ   Input   pin   Input contact   point   Optocoupler   DIO-4/4(FIT)GY   3 Ver.1.00   Using Outputs Y0   + External   power supply   12V - 48VDC   Load   Output plus common   - Output pin (e.g., connector Y1)   Output minus common   Example of Connecting Outputs and Inputs   External   power supply   12V - 24VDC   - + Intput module   Common plus for intput   Output module   Common plus for output   Output   Intput   Common minus for output   Setting a Device ID   The controller module distinguishes and keeps track of the   modules that are connected to it by assigning device IDs to   them. Each module, therefore, should be assigned a unique   ID.   A Device ID can be assigned in a 0 - 7 range, so that a   maximum of eight modules can be distinguished.   The factory setting for the Device ID is [0].   Setup Method   A Device ID can be set by turning the rotary switch that is   located on the module face.   A Device ID can be assigned by turning the switch.   6 Device   ID   Factory setting:   (Device ID = 0)   2 DIO-4/4(FIT)GY   4 |