					Contents:   
					Installation Instructions:   
					page 2   
					Pump Specifications - LP122A/LP122A-4000 page 3   
					Pump Specifications - LP123:   
					Exploded View:   
					page 3   
					page 4   
					Parts List/Kits:   
					page 5   
					Pump Specifications - LP255:   
					Trobleshooting Guide:   
					Suggested Maintenance Schedule:   
					Repair Instructions/Torque Specs.:   
					Dimensions:   
					page 6   
					page 7   
					page 7   
					pages 8-10   
					page 11   
					back page   
					Updated 12/06   
					WarrantyInformation:   
				Specifications   
					Models LP122A/LP122A-4000/LP123   
					U.S. .....................................(Metric)   
					Volume (Continuous) ........................................... 35.4 GPM ............................(134 l/m)   
					Volume (Intermittent)........................................... 40 GPM ...............................(151.4 l/m)   
					Discharge Pressure (Continuous) ........................ 1300 PSI ..............................(90 Bar)   
					Discharge Pressure (Intermittent) ....................... 2000 PSI ..............................(138 Bar)   
					Inlet Pressure....................................................... Up to 90 PSI .......................(Up to 6.2 Bar)   
					Speed (Continuous)............................................................................................Up to 800 RPM*   
					Speed (Intermittent) ...........................................................................................Up to 885 RPM**   
					Plunger Diameter................................................. 1.65” ....................................(42 mm)   
					Stroke................................................................... 1.65” ....................................(42 mm)   
					Crankcase Oil Capacity ....................................... 116 fl.oz. ..............................(3.43 liters)   
					Temperature of Pumped Fluids............................ Up to 160oF .........................(Up to 71oC)   
					Inlet Ports ..........................................................................................................2 x 1-1/2" NPT   
					Discharge Ports .................................................................................................2 x 1" NPT   
					Crankshaft Mounting .........................................................................................Either Side   
					Shaft Rotation ...................................................... Top of Pulley Towards Fluid End   
					Weight .................................................................. 116 lbs. ................................(52.7 Kg)   
					Crankshaft Diameter ........................................... 1.38” ....................................(35 mm)   
					Valve Casing - LP122A .....................................................................................Aluminum Bronze   
					Valve Casing - LP123 ........................................................................................Brass   
					Valve Casing - LP122A-4000 ............................................................................303 S.S.   
					Volumetric Efficiency @ 800 RPM ...................................................................0.96   
					Mechanical Efficiency @ 800 RPM .................................................................0.85   
					*Pump speeds of 640 RPM and above require a minimum inlet pressure of 12 psig.   
					**Pump speeds of 805 RPM and above require a minimum inlet pressure of 14 psig.   
					PULLEY INFORMATION   
					Pulley selection and pump speed are based on a   
					1725 RPM motor and "B" section belts. When   
					selecting desired GPM, allow for a ±5% toler-   
					ance on pumps output due to variations in   
					pulleys, belts and motors among manufactur-   
					ers.   
					1. Select GPM required, then select   
					appropriatemotor and pump pulley from the   
					same line.   
					2. The desired pressure is achieved by selecting   
					the correct nozzle size that corresponds with the   
					pump GPM.   
					HORSEPOWER INFORMATION   
					We recommend that a 1.1 service factor be speci-   
					fied when s electing an electric motor as the power   
					source. To compute specific pump horsepower   
					requirements, use the following formula:   
					HP = (GPM X PSI) / 1440   
					LP122A/LP122A-4000/LP123 PULLEY SELECTION AND HORSEPOWER   
					REQUIREMENTS   
					PUMP   
					PULLEY PULLEY   
					MOTOR   
					GPM   
					RPM   
					600 PSI   
					800 PSI 1000 PSI 1300 PSI 2000 PSI*   
					22.3   
					24.7   
					28.5   
					30.9   
					33.4   
					35.6   
					39.4   
					12.75"   
					12.75"   
					12.75"   
					12.75"   
					12.75"   
					12.75"   
					12.75"   
					3.95"   
					4.35"   
					4.95"   
					5.35"   
					5.75"   
					6.15"   
					6.50"   
					500   
					555   
					640   
					695   
					750   
					800   
					885*   
					9.6   
					12.7   
					14.1   
					16.3   
					17.7   
					19.1   
					20.3   
					22.5   
					15.9   
					17.6   
					20.4   
					22.1   
					23.9   
					25.4   
					28.1   
					20.7   
					22.9   
					26.5   
					28.7   
					31.0   
					33.1   
					36.6   
					31.9   
					35.3   
					40.7   
					44.1   
					47.7   
					50.9   
					56.3   
					10.6   
					12.2   
					13.2   
					14.3   
					15.3   
					16.9   
					*Intermittent duty only! - Consult factory!   
					3 
				Exploded View - LP122A/LP122A-4000/LP123/LP255   
					4 
				LP122A/LP122A-4000/LP123/LP255 PARTS LIST   
					A = LP122A B = LP123   
					C = LP122-4000   
					E = LP255   
					ITEM PARTNO. DESCRIPTION   
					QTY.   
					1 
					ITEM PARTNO. DESCRIPTION   
					QTY.   
					3 
					1 
					07759   
					13000   
					06085   
					07104   
					07186   
					06086   
					01009   
					01010   
					Crankcase   
					35B   
					36   
					13141   
					13415   
					13025   
					13416A   
					06700   
					06701   
					07744   
					13026   
					07745   
					13027   
					07746   
					06702   
					13343   
					06625   
					O-Ring(Eonly)   
					2 
					OilFillerPlug   
					CrankcaseCover   
					O-Ring   
					1 
					V-Sleeve,Weep(A-C)   
					V-Sleeve,Weep(E)   
					PressureRing,Weep,(A,B,C)   
					PressureRing(E)   
					3 
					4 
					1 
					36   
					3 
					5 
					1 
					36A   
					36A   
					37   
					3 
					6 
					OilSightGlassW/Gasket   
					OilDipstick   
					1 
					3 
					8 
					1 
					SupportDisc(Eonly)   
					PressureRing,(A,B,C)   
					PressureRing(E)   
					3 
					9 
					O-Ring   
					1 
					39   
					3 
					10   
					11   
					12   
					13   
					14   
					15   
					16   
					17   
					20   
					20A   
					20B   
					21   
					22   
					23   
					24   
					24A   
					24B   
					25   
					Screw, (A, B, C, E)   
					4 
					39   
					6 
					01011-0400 SpringWasher,(A,B,C)   
					5 
					40   
					V-Sleeve(A,B,C,D)   
					V-Sleeve(E)   
					6 
					07109   
					07182   
					07111   
					07112   
					07113   
					07114   
					07116   
					07117   
					13001   
					07118   
					13242   
					13243   
					13340   
					13277   
					13278   
					13341   
					OilDrainPlug   
					Gasket   
					1 
					40   
					6 
					1 
					41   
					SupportRing,(A,B,C)   
					SupportRing(E)   
					3 
					BearingCover   
					CrankshaftSeal   
					O-Ring   
					2 
					41   
					3 
					2 
					43   
					ValveCasing,(A)   
					1 
					2 
					43   
					ValveCasing,(B)   
					1 
					HexScrew   
					8 
					43   
					13343-4000 ValveCasing,(C)   
					1 
					TaperRollerBearing   
					FittingDisc,0.1mm   
					FittingDisc,0.15mm   
					ShaftProtector   
					Crankshaft   
					2 
					43   
					06703   
					07748   
					07150   
					07749   
					07750   
					07751   
					ValveCasing,(E)   
					ValveSeat   
					O-Ring   
					1 
					2 
					44   
					6 
					3 
					44A   
					45   
					6 
					1 
					ValvePlate   
					ValveSpring   
					ValveAssy.Complete   
					(#44,44A,45,46,&47)   
					SpringRetainer   
					Plug,(A)   
					6 
					1 
					46   
					6 
					Key   
					1 
					46A   
					ConnectingRodAssy.   
					HexScrew   
					3 
					6 
					6 
					6 
					6 
					6 
					6 
					8 
					8 
					8 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					6 
					47   
					07752   
					07753   
					06504   
					06089   
					12055   
					07157   
					07158   
					07159   
					07423   
					SpringWasher   
					CrossheadPlunger   
					BaseAssy.   
					6 
					48   
					48   
					Plug,(B,E)   
					Plug,(C)   
					3 
					3 
					3 
					3 
					3 
					3 
					3 
					3 
					3 
					3 
					3 
					3 
					3 
					48   
					28   
					13232   
					07735   
					07736   
					13022   
					07737   
					07755   
					06087   
					07789   
					07133   
					13342   
					06699   
					07740   
					CrossheadPin   
					CenteringSleeve   
					PlungerPipe(A-C)   
					PlungerPipe(E)   
					PlungerBolt   
					48A   
					49   
					O-Ring   
					29A   
					29B   
					29B   
					29C   
					29D   
					29E   
					30   
					StudBolt   
					49A   
					49B   
					50   
					Nut   
					Washer   
					Plug,(A,B,E)   
					CopperGasket   
					SpacerPipe   
					50   
					07423-0100 Plug,(C)   
					50A   
					52   
					07161   
					13020   
					06607   
					07756   
					06626   
					07757   
					06627   
					Gasket   
					DiskforCrankshaft   
					HexagonScrew   
					Flinger   
					31   
					RadialShaftSeal   
					SealSleeve,(A,B,C)   
					SealSleeve(E)   
					O-Ring   
					53   
					35   
					54   
					Plug1"NPT,(A,C)   
					Plug1"NPT,(B,E)   
					Plug1-1/2"NPT,(A,C)   
					Plug,1-1/4"NPT,(B,E)   
					35   
					54   
					35A   
					55   
					55   
					NOTE: For LP122 pumps manufactured prior to 5/94, which need weep seal replacement, change the pressure ring   
					(36) to the newer style (p/n 13416) and use the new style weep seal (p/n 13415) in your pumps.   
					LP122A/LP122A-4000/LP123/LP255 PUMP REPAIR KITS   
					Plunger Packing Kit   
					Valve Assembly Kit - #09136   
					# 09477 (LP122A, LP123, LP122A-4000)   
					(for pumps manufatured after 4/98)   
					Item   
					46A   
					48A   
					Part # Description   
					Qty.   
					3 
					3 
					07751 Valve Assembly, Complete   
					12055 O-Ring   
					Item   
					35A   
					36   
					Part #   
					07740 O-ring   
					13415 V-Sleeve, Weep   
					07745 V-Sleeve   
					Description   
					Qty.   
					3 
					3 
					6 
					40   
					Plunger Packing Kit   
					# 09535 (LP255)   
					Item   
					35A   
					35B   
					36   
					Part #   
					Description   
					Qty.   
					07740 O-ring   
					13141 O-Ring   
					13025 V-Sleeve weep   
					13027 V-Sleeve   
					3 
					3 
					3 
					6 
					40   
					5 
				Specifications   
					Model LP255   
					U.S. .....................................(Metric)   
					Volume ................................................................. 26.0 GPM ............................(98 l/min)   
					Discharge Pressure ............................................. 2175 PSI ..............................150 Bar)   
					Inlet Pressure....................................................... Up to 90 PSI .......................Up to 6.2 Bar)   
					Speed .................................................................................................................Up to 1000 RPM   
					Plunger Diameter................................................. 1.26” ....................................(32 mm)   
					Stroke................................................................... 1.65” ....................................(42 mm)   
					Crankcase Oil Capacity ....................................... 116 fl.oz. ..............................(3.43 liters)   
					o 
					Temperature of Pumped Fluids............................ Up to 160oF .........................(70 C)   
					Inlet Ports ..........................................................................................................2 x 1-1/2" NPT   
					Discharge Ports .................................................................................................2 x 1" NPT   
					Crankshaft Mounting .........................................................................................Either Side   
					Shaft Rotation ...................................................... Top of Pulley Towards Fluid End   
					Weight .................................................................. 116 lbs. ................................(52.7 Kg)   
					Crankshaft Diameter ........................................... 1.38” ....................................(35 mm)   
					Valve Casing ......................................................................................................Brass   
					Volumetric Efficiency @ 800 RPM ...................................................................0.96   
					Mechanical Efficiency @ 800 RPM .................................................................0.85   
					HORSEPOWER INFORMATION   
					We recommend that a 1.1 service factor be speci-   
					fied when s electing an electric motor as the power   
					source. To compute specific pump horsepower   
					requirements, use the following formula:   
					PULLEY INFORMATION   
					Pulley selection and pump speed are based on a 1725   
					RPM motor and "B" section belts. When selecting   
					desired GPM, allow for a ±5% tolerance on pumps   
					output due to variations in pulleys, belts and motors   
					among manufacturers.   
					HP = (GPM X PSI) / 1440   
					1. Select GPM required, then select appropriate   
					motor and pump pulley from the same line.   
					2. The desired pressure is achieved by selecting the   
					correct nozzle size that corresponds with the   
					pump   
					GPM.   
					LP255 PULLEY SELECTION AND HORSEPOWER REQUIREMENTS   
					PUMP   
					PULLEY PULLEY   
					MOTOR   
					RPM   
					GPM   
					1000 PSI 1500 PSI 2000 PSI 2175 PSI   
					12.75"   
					12.75"   
					12.75"   
					12.75"   
					12.75"   
					12.75"   
					12.75"   
					3.95"   
					4.35"   
					4.95"   
					5.35"   
					5.75"   
					6.15"   
					6.50"   
					500   
					640   
					750   
					805   
					865   
					920   
					1000   
					13   
					9.0   
					13.5   
					17.3   
					20.3   
					21.8   
					23.4   
					24.9   
					27.1   
					18.1   
					23.1   
					27.1   
					29.0   
					31.3   
					33.2   
					36.1   
					19.6   
					25.1   
					29.5   
					31.6   
					34.0   
					36.1   
					39.3   
					16.6   
					19.5   
					20.9   
					22.5   
					23.9   
					26   
					11.5   
					13.5   
					14.5   
					15.6   
					16.6   
					18.1   
					6 
				PUMPSYSTEMMALFUNCTION   
					MALFUNCTION   
					CAUSE   
					REMEDY   
					The Pressure and/   
					or the Delivery   
					Drops   
					Worn packing seals   
					Broken valve spring   
					Belt slippage   
					Replace packing seals   
					Replace spring   
					Tighten or Replace belt   
					Replace nozzle   
					Clean valve assembly   
					Clean strainer   
					Repair/Replace hose   
					Clean, Reset, and Replace worn parts   
					Check suction lines on inlet of   
					Worn or Damaged nozzle   
					Fouled discharge valve   
					Fouled inlet strainer   
					Worn or Damaged hose   
					Worn or Plugged relief valve on pump   
					Cavitation   
					pump for restrictions   
					Unloader   
					Check for proper operation   
					Water in crankcase   
					Noisy Operation   
					High humidity   
					Worn seals   
					Reduce oil change interval   
					Replace seals   
					Worn bearings   
					oil with   
					Cavitation   
					Replace bearings, Refill crankcase   
					recommended lubricant   
					Check inlet lines for restrictions   
					and/or proper sizing   
					Rough/Pulsating   
					Operation with   
					PressureDrop   
					Worn packing   
					Inlet restriction   
					Replace packing   
					Check system for stoppage, air   
					leaks, correctly sized inlet   
					plumbing to pump   
					Accumulator pressure   
					Unloader   
					Cavitation   
					Recharge/Replace accumulator   
					Check for proper operation   
					Check inlet lines for restrictions   
					and/or proper size   
					Pump Pressure as   
					Rated, Pressure   
					Drop at Gun   
					Restricted discharge plumbing   
					Re-size discharge plumbing to Flow   
					Rate of Pump   
					Excessive   
					Leakage   
					Worn plungers   
					Replace plungers   
					Worn packing/seals   
					Excessive vacuum   
					Cracked plungers   
					Inlet pressure too high   
					Adjust or Replace packing seals   
					Reduce suction vacuum   
					Replace plungers   
					Reduce inlet pressure   
					High Crankcase   
					Temperature   
					Wrong Grade of oil   
					Improper amount of oil in crankcase   
					Giant oil is recommended   
					Adjust oil level to proper amount   
					Preventative Maintenance Check-List & Recommended Spare Parts List   
					Check   
					Daily   
					Weekly   
					50hrs   
					Every   
					500 hrs   
					Every   
					1500 hrs   
					Every   
					3000 hrs   
					Oil Level/Quality   
					Oil Leaks   
					Water Leaks   
					Belts, Pulley   
					Plumbing   
					X 
					X 
					X 
					X 
					X 
					Recommended Spare Parts   
					Oil Change (1 Gallon) p/n 1154   
					Seal Spare Parts (1 kit/pump)   
					(See page 5 for kit list)   
					X 
					X 
					X 
					X 
					Oil Seal Kit (1 kit/pump)   
					(See page 5 for kit lit)   
					Valve Spare Parts (1 kit/pump)   
					(See page 5 for kit list)   
					X 
					7 
				LP122A/LP122A-4000/LP123/LP255 - Repair Instructions   
					44A   
					44   
					45   
					48   
					47   
					1. With a 30mm wrench, re-   
					move the six (6) plugs   
					(48) from the valve cas-   
					ing (43). Inspect the o-   
					rings (48A) and replace if   
					necessary.   
					2. To disassemble the valve, screw the bolt into the retainer   
					until the valve plate (45) presses the valve seat (44) out of   
					the spring retainer. Examine all parts and replace if neces-   
					sary. If the seat doesn’t come out, use a valve puller to   
					remove.   
					Remove the complete   
					valve assembly (46A) by   
					threading a 12mm bolt   
					into the spring retainer and   
					pulling straight out.   
					36A 36   
					35   
					35A   
					35B   
					39   
					40   
					40   
					41   
					37   
					(LP255 only)   
					(LP255 only)   
					4. Remove the seal sleeve (35) from the manifold and/or   
					crankcase. Remove the pressure rings (39&36A), v-sleeves   
					(40&36), support ring (41) and o-rings (35A and 35B in   
					Lp255A only) from the manifold and seal sleeve, respec-   
					tively. For LP255 only, remove support ring (37). Examine   
					seals carefully and replace if worn. Clean all parts.   
					3. Remove the eight (8) hex   
					nuts (49A) with a 19mm   
					wrench. Tap the back of   
					the manifold (43) with a   
					rubber mallet to dislodge   
					and slide off the studs.   
					5. If there are signs of   
					oil leaking through the   
					plunger oil seals, then   
					replacment is neccessary.   
					Dissassemble the gear   
					end and push out the   
					seals from the back of   
					the pump.   
					29E 29A   
					29B   
					29D   
					29C   
					6. Inspect surface of plunger pipe (29B) carefully. Remove   
					any chemical or mineral deposits taking care not to damage   
					the surface of the plunger. If plunger pipe is worn, remove   
					the plunger bolt (29C) , plunger pipe (29B) and spacer   
					(29E). Replace worn parts necessary. Note: Always use a   
					new copper gasket (29) when repairing the plunger assem-   
					bly.   
					8 
				LP122A/LP122A-4000/LP123/LP255 - Repair Instructions   
					TO REASSEMBLE PROCEED AS FOLLOWS:   
					29E 29A   
					29B   
					29D   
					29C   
					7. If previously disassembled thoroughly clean all exposed surfaces on the   
					spacer (29E) and all exposed threads on the plunger bolt (29C) and the   
					steelplungerbase(25).ThreadsMUSTbefreeofoldloc-titeandanyother   
					material such as oil, grease, etc. This is necessary to ensure proper curing   
					of new loc-tite. Giant recommends cleaning the threads with acetone or   
					other suitable cleaner. Reassemble plunger assembly parts (29A, 29B, &   
					29E)usinganewcoppergasket(29D)andthecleanedplungerbolt(29C).   
					Slide the bolt through the center of the four (4) pieces so that the threaded   
					end is exposed. Apply several drops of loc-tite 243 (or equivalent)   
					adhesive to the threads. Thread into steel plunger base and tighten to 26   
					ft.-lbs.BECERTAINALLPARTSARECENTEREDWITHTHEBOLT!   
					36A   
					36   
					35   
					35A 35B (LP255 only)   
					39   
					8. Lubricate weep seal (36). Place, weep seal (36), and pressure ring (36A)   
					into the seal sleeve (35). Assemble the o-ring (35A and 35B for LP255   
					only) onto seal sleeve and lubricate.   
					9. For LP255 pumps, insert sup-   
					port ring (37) into valve casing   
					(43).Placesupportring(41)and   
					v-sleeves (40) into valve   
					casing.   
					7 
					6 
					8 
					4 
					1 
					2 
					3 
					5 
					10. Place entire manifold/seal   
					sleeve assembly over the studs   
					and push firmly until seated   
					against the crankcase.   
					11. Tighten hex nuts (49A) in a   
					crosswisepattern(shownabove)   
					to 60 ft.-lbs.   
					9 
				LP122A/LP122A-4000/LP123/LP255 - Repair Instructions   
					14. Fill crankcase with approxi-   
					mately 116 fluid ounces of Gi-   
					ant oil or equivalent SAE 90   
					industrial gear oil and check oil   
					level of the crankcase with the   
					dipstick. Proper level is center   
					of two lines. Reinstall your Gi-   
					ant LP pump into your system.   
					12. Next, place valve assemblies   
					(46A) into manifold after first   
					lubricatingtheo-ring(44A).Seat   
					firmly into manifold.   
					13. Replace plug with o-ring (48, &   
					48A) and tighten to 160 ft.-lbs.   
					LP122A/LP122A-4000/LP123/LP255 TORQUE SPECIFICATIONS   
					Position   
					Item#   
					01010   
					07114   
					13277   
					07737   
					Description   
					Screw, Cover   
					Hex Screw, Bearing Cover   
					Hex Screw, Connecting Rod   
					Plunger Bolt   
					Torque Amount   
					125 in.-lbs.   
					125 in.-lbs.   
					250 in.-lbs.   
					26 ft.-lbs.   
					10   
					17   
					24A   
					29C   
					48   
					06504/06089   
					07158   
					Plug, Valve   
					Nut, Stud Bolt   
					160 ft.-lbs.   
					60 ft.-lbs.   
					49A   
					Contact Giant Industries or your local distributor for maintenance   
					of the gear end of your pump. Phone: 419/531-4600   
					Contact Giant Industries for service school information. Phone: (419) 531-4600   
					10   
				LP122A/LP123/LP255 Dimensions (mm)   
					LP122A-4000 Dimensions (mm)   
					11   
				GIANTINDUSTRIESLIMITEDWARRANTY   
					Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in   
					workmanship and material as follows:   
					1. For portable pressure washers and self-service car wash applications, the discharge manifolds will never   
					fail, period. If they ever fail, we will replace them free of charge. Our other pump parts, used in portable   
					pressure washers and in car wash applications, are warranted for five years from the dateof shipment for   
					all pumps used in NON-SALINE, clean water applications.   
					2. One (1) year from the date of shipment for all other Giant industrial and consumer pumps.   
					3. Six (6) months from the date of shipment for all rebuilt pumps.   
					4. Ninety (90) days from the date of shipment for all Giant accessories.   
					This warranty is limited to repair or replacement of pumps and accessories of which the manufacturer’s evaluation   
					shows were defective at the time of shipment by the manufacturer. The following items are NOT covered or will   
					void the warranty:   
					1. Defects caused by negligence or fault of the buyer or third party.   
					2. Normal wear and tear to standard wear parts.   
					3. Use of repair parts other than those manufactured or authorized by Giant.   
					4. Improper use of the product as a component part.   
					5. Changes or modifications made by the customer or third party.   
					6. The operation of pumps and or accessories exceeding the specifications set forth in the Operations   
					Manuals provided by Giant Industries, Inc.   
					Liability under this warranty is on all non-wear parts and limited to the replacement or repair of those products   
					returned freight prepaid to Giant Industries which are deemed to be defective due to workmanship or failure of   
					material. A Returned Goods Authorization (R.G.A.) number and completed warranty evaluation form is required prior   
					to the return to Giant Industries of all products under warranty consideration. Call (419)-531-4600 or fax (419)-531-   
					6836 to obtain an R.G.A. number.   
					Repair or replacement of defective products as provided is the sole and exclusive remedy provided hereunder and   
					the MANUFACTURER SHALL NOT BE LIABLE FOR FURTHER LOSS, DAMAGES, OR EXPENSES, INCLUDING   
					INCIDENTALANDCONSEQUENTIALDAMAGESDIRECTLYORINDIRECTLYARISINGFROMTHESALEORUSE   
					OF THIS PRODUCT.   
					THELIMITEDWARRANTYSETFORTHHEREINISINLIEUOFALLOTHERWARRANTIESORREPRESENTATION,   
					EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WARRANTIES OR MERCHANTABILITY OR   
					FITNESS FOR A PARTICULAR PURPOSE AND ALL SUCH WARRANTIES ARE HEREBY DISCLAIMED AND   
					EXCLUDED BY THE MANUFACTURER.   
					GIANT INDUSTRIES, INC., 900 N. Westwood Avenue, P.O. Box 3187, Toledo, OH 43607   
					
					 Copyright 2006 Giant Industries, Inc.   
					12/06 LP122A_LP123_LP255.PMD   
				 |